Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012 <strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong> <strong>Transmitters</strong> <strong>and</strong><br />

<strong>1199</strong> <strong>Seal</strong> <strong>Systems</strong><br />

FOR ROSEMOUNT 3051S, 3051, AND 2051<br />

TRANSMITTERS<br />

APPLICATIONS<br />

• <strong>Level</strong>, Flow, Pressure, Interface, Density<br />

• Extreme hot <strong>and</strong> cold temperatures<br />

• Corrosive, clogging, or viscous processes<br />

• Hygienic requirements<br />

• Special process connections<br />

www.rosemount.com<br />

Contents<br />

Proven, Reliable, <strong>and</strong> Innovative <strong>DP</strong> <strong>Level</strong> Technologies . . . . . . . . . . . . . . . . . . . . . page 2<br />

Ordering Information<br />

<strong>Rosemount</strong> 3051S Electronic Remote Sensor System. . . . . . . . . . . . . . . . . . page 4<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter . . . . . . . . . . . . . . . . . . . . . . . page 15<br />

<strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 32<br />

<strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38<br />

<strong>Rosemount</strong> <strong>1199</strong> Direct Mount <strong>Seal</strong> <strong>Systems</strong>. . . . . . . . . . . . . . . . . . . . . . . . page 43<br />

<strong>Rosemount</strong> <strong>1199</strong> Remote Mount <strong>Seal</strong> <strong>Systems</strong> . . . . . . . . . . . . . . . . . . . . . . page 48<br />

Flanged <strong>Seal</strong>s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 54<br />

Threaded <strong>Seal</strong>s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 70<br />

Hygienic <strong>Seal</strong>s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 74<br />

Specialty <strong>Seal</strong>s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 84<br />

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 89<br />

Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 100<br />

Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 114


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

2<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Proven, Reliable, <strong>and</strong> Innovative <strong>DP</strong> <strong>Level</strong> Technologies<br />

To meet your application requirements, <strong>Rosemount</strong> <strong>DP</strong> level technologies deliver an unsurpassed product offering<br />

that is easy to specify, order, <strong>and</strong> install. The offering includes a wide variety of process connections, direct mount<br />

or capillary connections, <strong>and</strong> materials of construction to address almost any application. If you don’t see what you<br />

need listed here, ask us. We can create a custom engineered solution to meet your needs.<br />

<strong>Rosemount</strong> <strong>Level</strong> <strong>Transmitters</strong><br />

<strong>Level</strong> transmitters combine world-class <strong>Rosemount</strong> pressure instrumentation with direct-mount seals, all in a single<br />

integrated model number.<br />

Balanced System Tuned-System Assembly<br />

Two equal lengths<br />

of capillary<br />

Direct mount<br />

plus capillary<br />

<strong>Rosemount</strong> 3051S Electronic Remote Sensor <strong>Systems</strong><br />

<strong>Rosemount</strong> 3051SAL, 3051L, <strong>and</strong> 2051L <strong>Level</strong> <strong>Transmitters</strong><br />

• Achieve best-in-class system reliability with All-Welded systems<br />

• Wireless configurations provide new data access<br />

• Connect to virtually any process with a comprehensive offering of<br />

process connections, fill fluids, direct mount or capillary<br />

connections, <strong>and</strong> materials<br />

• Quantify <strong>and</strong> optimize total system performance with QZ option<br />

<strong>Rosemount</strong> Tuned-System Assemblies Optimize Results<br />

• Reduce installed costs by 20% by eliminating excess capillary <strong>and</strong><br />

transmitter mounting hardware<br />

• Improve performance by up to 30%<br />

• Increase response time by up to 80%<br />

• Reduce risk with up-front quantified performance reports<br />

The <strong>Rosemount</strong> 3051S ERS System is a new digital <strong>DP</strong> <strong>Level</strong> architecture that links two 3051S pressure sensors<br />

together electronically. Differential pressure, level, <strong>and</strong> volume is calculated <strong>and</strong> transmitted using a st<strong>and</strong>ard<br />

two-wire 4-20 mA HART signal.<br />

A Digital Upgrade to a Proven Technology<br />

• 90% improvement in time response<br />

• Elimination of temperature effects <strong>and</strong> measurement drift<br />

• MultiVariable capabilities including <strong>DP</strong>, PLO, PHI, Volume, <strong>and</strong> <strong>Level</strong><br />

• Proven 3051S sensor technology<br />

Simplified Installations <strong>and</strong> Maintenance Routines<br />

• Elimination of wet legs or dry legs<br />

• Easy installations without need for heat tracing <strong>and</strong> insulation<br />

• Proactive maintenance <strong>and</strong> troubleshooting with sensor alerts <strong>and</strong> diagnostics<br />

• Simplified inventories with sensors <strong>and</strong> st<strong>and</strong>ard cable


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>1199</strong> <strong>Seal</strong> <strong>Systems</strong><br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

A seal system consists of a pressure transmitter, one or two seals, a fill fluid, <strong>and</strong> either a direct mount or capillary<br />

style connection. <strong>Seal</strong> systems provide a reliable process pressure measurement <strong>and</strong> prevent the process medium<br />

from contacting the transmitter diaphragm. Transmitter/diaphragm seal systems should be considered when:<br />

• The process temperature is outside of the operating ranges of the transmitter.<br />

• The process is corrosive <strong>and</strong>/ or requires specific exotic materials of construction.<br />

• The process contains suspended solids or is viscous <strong>and</strong> is prone to plugging of connections.<br />

• The application requires the use of flush-mount hygienic connections that facilitates CIP/SIP service.<br />

• There is a requirement for easier cleaning of the process from the connections to avoid contamination<br />

between batches.<br />

Application Flexibility<br />

• Flanged, threaded, <strong>and</strong> hygienic process connections<br />

• Meets industry st<strong>and</strong>ards such as EN 1092-1, ANSI/ASME<br />

B16.5, JIS B2238, ANSI/ASME B1.20.1, EN 10226-1, <strong>and</strong><br />

3-A St<strong>and</strong>ard 74-03<br />

• Variety of fill fluids including cold temperature<br />

(-102 °F / -75 °C), hot temperature (599 °F / 315 °C), <strong>and</strong><br />

hygienic & food grade<br />

• Three different capillary diameters allow for optimization of<br />

accuracy <strong>and</strong> time response<br />

Reliable System Construction<br />

• Welded design with no threaded connections<br />

• 100% Helium leak tested<br />

• Advanced manufacturing techniques ensure air-free,<br />

leak-tight system that is stable over time<br />

• Reliable operation in full vacuum applications<br />

Robust <strong>Seal</strong> Design<br />

• Backup convolutions on the diaphragm protect<br />

seal integrity<br />

• Recessed diaphragms reduce potential for<br />

h<strong>and</strong>ling damage<br />

• Advanced welding techniques improve reliability<br />

SST Armored, PVC Coated,<br />

Support Tube with Closed End<br />

(Ordering Codes M, N, <strong>and</strong> P)<br />

Table 15 on page 49<br />

SST Armored, Support Tube<br />

(Ordering Codes H, J, <strong>and</strong> K)<br />

Table 15 on page 49<br />

SST Armored, PVC Coated<br />

(Ordering Codes E, F, <strong>and</strong> G)<br />

Table 15 on page 49<br />

SST Armored<br />

(Ordering Codes B, C, <strong>and</strong> D)<br />

Table 15 on page 49<br />

3


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

4<br />

1<br />

Coplanar<br />

3051SAM<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> 3051S Electronic Remote Sensor System<br />

In-Line<br />

Coplanar In-Line<br />

3<br />

3051SAL<br />

Secondary<br />

Primary<br />

3051SAL1PG4AA1A1020DFF71DA00M5<br />

3051SAM1ST2A2E11A2A<br />

The 3051S ERS System is a flexible, 2-wire 4-20 mA HART<br />

architecture that calculates differential pressure (<strong>DP</strong>) electronically<br />

using two pressure sensors that are linked together with a<br />

non-proprietary electrical wire.<br />

Ideal applications for the 3051S ERS System include tall vessels <strong>and</strong><br />

distillation columns that have traditionally required long lengths of<br />

capillary or impulse piping. When used in these types of applications,<br />

the 3051S ERS System can deliver:<br />

• More accurate <strong>and</strong> repeatable <strong>DP</strong> measurements<br />

• Faster time response<br />

• Simplified installations<br />

• Reduced maintenance<br />

How to Order<br />

1. Choose two 3051S ERS transmitter models. These may be any<br />

combination of 3051SAM <strong>and</strong> 3051SAL models.<br />

2. Decide which model will be the ERS Primary (4-20 mA loop<br />

termination <strong>and</strong> optional LCD) <strong>and</strong> which will be the ERS<br />

Secondary. This will be specified by the “Configuration Type”<br />

code in each model number.<br />

3. Specify two full model numbers per the desired configuration.<br />

Additional Information<br />

Specifications: page 89<br />

Certifications: page 104<br />

Dimensional Drawings: page 114<br />

<strong>Rosemount</strong> 3051SAM Scalable ERS Measurement Transmitter<br />

• Coplanar <strong>and</strong> In-Line sensor module platforms<br />

• Variety of process connections including threaded NPT, flanges, manifolds, <strong>and</strong> <strong>1199</strong> remote<br />

seals<br />

• Available with 10-year stability <strong>and</strong> limited 12-year warranty<br />

Table 1. 3051SAM Scalable ERS Measurement Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Transmitter Type<br />

3051SAM Scalable ERS Measurement Transmitter<br />

Performance Class<br />

2<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Ultra: 0.025% span accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty ★<br />

2 Classic: 0.055% span accuracy, 100:1 rangedown, 5-year stability ★<br />

Configuration Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

P Electronic Remote Sensor - Primary ★<br />

S Electronic Remote Sensor - Secondary ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Pressure Module Type Pressure Sensor Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

G Coplanar Gage ★<br />

T In-Line Gage ★<br />

E<br />

Exp<strong>and</strong>ed<br />

In-Line Absolute ★<br />

A Coplanar Absolute<br />

Pressure Range (1)<br />

Table 1. 3051SAM Scalable ERS Measurement Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Coplanar Gage In-Line Gage In-Line Absolute Coplanar Absolute<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1A N/A -14.7 to 30 psig<br />

(-1,0 to 2,06 bar)<br />

2A -250 to 250 inH2O<br />

(-623 to 623 mbar)<br />

3A -393 to 1000 inH2O<br />

(-0,98 to 2,49 bar)<br />

4A -14.2 to 300 psig<br />

(-0,98 to 20,7 bar)<br />

5A -14.2 to 2000 psig<br />

(-0,98 to 137,9 bar)<br />

-14.7 to 150 psig<br />

(-1,0 to 10,34 bar)<br />

-14.7 to 800 psig<br />

(-1,0 to 55,2 bar)<br />

-14.7 to 4000 psig<br />

(-1,0 to 275,8 bar)<br />

-14.7 to 10000 psig<br />

(-1,0 to 689,5 bar)<br />

0 to 30 psia<br />

(0 to 2,06 bar)<br />

0 to 150 psia<br />

(0 to 10,34 bar)<br />

0 to 800 psia<br />

(0 to 55,2 bar)<br />

0 to 4000 psia<br />

(0 to 275,8 bar)<br />

0 to 10000 psia<br />

(0 to 689,5 bar)<br />

0 to 30 psia<br />

★<br />

(0 to 2,06 bar)<br />

0 to 150 psia<br />

★<br />

(0 to 10,34 bar)<br />

0 to 800 psia<br />

★<br />

(0 to 55,2 bar)<br />

0 to 4000 psia<br />

★<br />

(0 to 275,8 bar)<br />

N/A ★<br />

Isolating Diaphragm<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 (2) 316L SST ★<br />

3 (2) Exp<strong>and</strong>ed<br />

Alloy C-276 ★<br />

4 (3) Alloy 400<br />

5 (3)(4) Tantalum<br />

6 (3)<br />

Gold-plated Alloy 400 (includes Graphite-Filled PTFE O-Ring)<br />

7 (3)<br />

Gold-plated 316L SST<br />

Process Connection<br />

Coplanar Module Type In-Line Module Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

000 None N/A ★<br />

A11 (5)<br />

Assemble to <strong>Rosemount</strong> 305 Manifold Assemble to <strong>Rosemount</strong> 306 Manifold ★<br />

A12 (5)<br />

Assemble to <strong>Rosemount</strong> 304 or AMF Manifold with SST<br />

Traditional Flange<br />

N/A ★<br />

B11 (5)(6)<br />

Assemble to One <strong>Rosemount</strong> <strong>1199</strong> Remote Diaphragm<br />

<strong>Seal</strong> with SST transmitter flange<br />

Assemble to One <strong>Rosemount</strong> <strong>1199</strong> Remote<br />

Diaphragm<br />

E11 Coplanar Flange (CS), ¼-18 NPT, 316 SST Drain Vents ½ -14 NPT Female ★<br />

E12 Coplanar Flange (SST), ¼-18 NPT, 316 SST Drain Vents N/A ★<br />

E13 (2)<br />

Coplanar Flange (Cast C-276), ¼-18 NPT, Alloy C-276<br />

Drain Vents<br />

N/A ★<br />

E14 Coplanar Flange (Cast Alloy 400), ¼-18 NPT, Alloy<br />

400/K-500 Drain Vents<br />

N/A ★<br />

E15 (2)<br />

Coplanar Flange (SST), ¼-18 NPT, Alloy C-276 Drain<br />

Vents<br />

N/A ★<br />

E16 (2) Coplanar Flange (CS), ¼-18 NPT, Alloy C-276 Drain Vents N/A ★<br />

E21 Coplanar Flange (CS), RC ¼, 316 SST Drain Vents N/A ★<br />

E22 Coplanar Flange (SST), RC ¼, 316 SST Drain Vents N/A ★<br />

E23 (2) Coplanar Flange (Cast C-276), RC ¼, Alloy C-276 Drain<br />

Vents<br />

N/A ★<br />

E24 Coplanar Flange (Cast Alloy 400), RC ¼, alloy 400/K-500<br />

Drain Vents<br />

N/A ★<br />

E25 (2)<br />

Coplanar Flange (SST), RC ¼, Alloy C-276 Drain Vents N/A ★<br />

★<br />

5


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

6<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

E26 (2) Coplanar Flange (CS), RC ¼, Alloy C-276 Drain Vents N/A ★<br />

F12 Traditional Flange (SST), 1 /4-18 NPT, 316 SST Drain Vents N/A ★<br />

F13 (2)<br />

Traditional Flange (Cast C-276), 1 /4-18 NPT, Alloy C-276<br />

Drain Vents<br />

N/A ★<br />

F14 Traditional Flange (Cast Alloy 400), 1 /4-18 NPT, Alloy<br />

400/K-500 Drain Vents<br />

N/A ★<br />

F15 (2) Traditional Flange (SST), 1 /4-18 NPT, Alloy C-276 Drain<br />

Vents<br />

N/A ★<br />

F22 Traditional Flange (SST), RC ¼, 316 SST Drain Vents N/A ★<br />

F23 (2) Traditional Flange (Cast C-276), RC ¼, Alloy C-276 Drain<br />

Vents<br />

N/A ★<br />

F24 Traditional Flange (Cast Alloy 400), RC ¼, Alloy 400/K500<br />

Drain Vents<br />

N/A ★<br />

F25 (2) Table 1. 3051SAM Scalable ERS Measurement Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Traditional Flange (SST), RC ¼, Alloy C-276 Drain Vents N/A ★<br />

F52 DIN-Compliant Traditional Flange (SST), ¼-18 NPT, 316<br />

Drain Vents, 7-16-in. Bolting<br />

N/A ★<br />

G11 Vertical Mount <strong>Level</strong> Flange (SST), 2-in ANSI Class 150,<br />

316 SST Drain Vents<br />

G ½ A DIN 16288 Male (Range 1-4 Only) ★<br />

G12 Vertical Mount <strong>Level</strong> Flange (SST), 2-in ANSI Class 300,<br />

316 SST Drain Vents<br />

N/A ★<br />

G21 Vertical Mount <strong>Level</strong> Flange (SST), 3-in ANSI Class 150,<br />

316 SST Drain Vents<br />

N/A ★<br />

G22 Vertical Mount <strong>Level</strong> Flange (SST), 3-in ANSI Class 300,<br />

316 SST Drain Vents<br />

N/A ★<br />

G31 Vertical Mount <strong>Level</strong> Flange (SST), DIN-DN 50 PN 40, 316<br />

SST Drain Vents<br />

N/A ★<br />

G41<br />

Exp<strong>and</strong>ed<br />

Vertical Mount <strong>Level</strong> Flange (SST), DIN-DN 80 PN 40, 316<br />

SST Drain Vents<br />

N/A ★<br />

F11 Traditional Flange (CS), ¼-18 NPT, 316 SST Drain / Vents Non-Threaded Instrument Flange (I-Flange)<br />

F32 Bottom Vent Traditional Flange (SST), ¼-18 NPT, 316 SST<br />

Drain Vents<br />

N/A<br />

F42 Bottom Vent Traditional Flange (SST), RC ¼, 316 SST<br />

Drain Vents<br />

N/A<br />

F62 DIN-Compliant Traditional Flange (316 SST), ¼-18 NPT,<br />

316 Drain Vents, M10 Bolting<br />

N/A<br />

F72 DIN-Compliant Traditional Flange (316 SST), ¼-18 NPT,<br />

316 Drain Vents, M12 Bolting<br />

N/A<br />

Transmitter Output<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 4–20 mA with digital signal based on HART protocol ★<br />

Housing Style Material Conduit Entry Size<br />

St<strong>and</strong>ard<br />

Housings for ERS Primary - Configuration Type code P<br />

St<strong>and</strong>ard<br />

1A PlantWeb Housing Aluminum 1 /2–14 NPT ★<br />

1B PlantWeb Housing Aluminum M20 x 1.5 (CM 20) ★<br />

1J PlantWeb Housing SST 1 /2–14 NPT ★<br />

1K PlantWeb Housing SST M20 x 1.5 (CM 20) ★<br />

2E Junction Box with Remote Display Output Aluminum<br />

1<br />

/2–14 NPT ★<br />

2F Junction Box with Remote Display Output Aluminum M20 x 1.5 (CM 20) ★<br />

2M Junction Box with Remote Display Output SST 1 /2–14 NPT ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

St<strong>and</strong>ard<br />

Housings for ERS Secondary - Configuration Type code S<br />

St<strong>and</strong>ard<br />

2A Junction Box Aluminum 1 /2–14 NPT ★<br />

2B Junction Box Aluminum M20 x 1.5 (CM 20) ★<br />

2J<br />

Exp<strong>and</strong>ed<br />

Junction Box SST<br />

1<br />

/2–14 NPT ★<br />

Housings for ERS Primary - Configuration Type code P<br />

1C PlantWeb Housing Aluminum G1 /2<br />

1L PlantWeb Housing SST G1 /2<br />

2G Junction Box with Remote Display Output Aluminum G 1 /2<br />

Housings for ERS Secondary - Configuration Type code S<br />

2C Junction Box Aluminum G1 Table 1. 3051SAM Scalable ERS Measurement Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

/2<br />

Options (Include with selected model number)<br />

Electronic Remote Sensor Connection Cable<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

R05 50 ft. (15.2 m) Spool of Electronic Remote Sensor Cable ★<br />

R10 100 ft. (30.5 m) Spool of Electronic Remote Sensor Cable ★<br />

R15 150 ft. (45.7m) Spool of Electronic Remote Sensor Cable ★<br />

Mounting Bracket<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

B1 (3) Traditional flange bracket, CS, 2-in. pipe ★<br />

B2 (3)<br />

Traditional flange bracket, CS, panel ★<br />

B3 (3)<br />

Traditional flange flat bracket, CS, 2-in. pipe ★<br />

B4 Bracket, all SST, 2-in. Pipe <strong>and</strong> Panel ★<br />

B7 (3) Traditional flange bracket, B1 with SST bolts ★<br />

B8 (3) Traditional flange bracket, B2 with SST bolts ★<br />

B9 (3) Traditional flange bracket, B3 with SST bolts ★<br />

BA (3)<br />

Traditional flange bracket, B1, all SST ★<br />

BC (3)<br />

Traditional flange bracket, B3, all SST ★<br />

Special Configuration (Software)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C1 (7) Customer Software Configuration (“Configuration Data Sheet” Must Be Completed) ★<br />

C3 Gage Pressure Calibration on <strong>Rosemount</strong> 3051SAM_ _A4 only ★<br />

C4 (7)<br />

NAMUR Alarm <strong>and</strong> Saturation <strong>Level</strong>s, High Alarm ★<br />

C5 (7)<br />

NAMUR Alarm <strong>and</strong> Saturation <strong>Level</strong>s, Low Alarm ★<br />

C6 (7) Custom Alarm <strong>and</strong> Saturation <strong>Level</strong>s, High Alarm (Requires C1 <strong>and</strong> Configuration Data Sheet) ★<br />

C7 (7) Custom Alarm <strong>and</strong> Saturation <strong>Level</strong>s, Low Alarm (Requires C1 <strong>and</strong> Configuration Data Sheet) ★<br />

C8 (7) Low alarm (st<strong>and</strong>ard <strong>Rosemount</strong> alarm <strong>and</strong> saturation levels) ★<br />

Special Configuration (Hardware)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D2 (8) 1 /2-14 NPT Flange Adapters ★<br />

D4 External ground screw assembly ★<br />

D5 (8) Exp<strong>and</strong>ed<br />

Delete transmitter drain/vent valves (install plugs) ★<br />

D7 (8)<br />

Coplanar flange without drain/vent ports<br />

D9 (8)<br />

RC 1 /2 Flange Adapters<br />

Product Certifications<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

E1 ATEX Flameproof ★<br />

I1 ATEX Intrinsic Safety ★<br />

N1 ATEX Type n ★<br />

7


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

8<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

K1 ATEX Flameproof <strong>and</strong> Intrinsically Safe, Type n, Dust ★<br />

ND ATEX Dust ★<br />

E4 TIIS Flameproof ★<br />

E5 FM Explosion-proof, Dust Ignition-proof ★<br />

I5 FM Intrinsically Safe, Division 2 ★<br />

K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

E6 (9) CSA Explosion-proof, Dust Ignition-proof, Division 2 ★<br />

I6 CSA Intrinsically Safe ★<br />

K6 (9)<br />

Table 1. 3051SAM Scalable ERS Measurement Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

E7 IECEx Flameproof ★<br />

I7 IECEx Intrinsic Safety ★<br />

N7 IECEx Type n ★<br />

K7 IECEx Flameproof, Intrinsic Safety, Type n ★<br />

E2 INMETRO Flameproof ★<br />

I2 INMETRO Intrinsically Safe ★<br />

K2 INMETRO Flameproof, Intrinsic Safety, Type n ★<br />

E3 China Flameproof ★<br />

I3 China Intrinsic Safety, Dust Ignition-proof ★<br />

KA (9) ATEX <strong>and</strong> CSA Flameproof, Intrinsically Safe, Division 2 ★<br />

KB (9)<br />

FM <strong>and</strong> CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

KC FM <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe, Division 2 ★<br />

KD (9) FM, CSA, <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe ★<br />

Special Certifications<br />

Calibration Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q4 Calibration certificate ★<br />

QP Calibration Certificate <strong>and</strong> Tamper Evident <strong>Seal</strong> ★<br />

Material Traceability Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q8 Material Traceability Certification per EN 10204 3.1 ★<br />

Quality Certification for Safety<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QS Prior-use certificate of FMEDA Data ★<br />

Surface Finish Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q16 Surface Finish Certification for Hygienic Remote <strong>Seal</strong>s ★<br />

Toolkit Performance Reports<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QZ (10)<br />

Remote <strong>Seal</strong> System Performance Calculation Report ★<br />

Terminal Blocks<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T1 (7) Transient Terminal Block ★<br />

Sensor Fill Fluid<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L1 (11) Inert Sensor Fill Fluid ★<br />

O-Ring<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L2 Graphite-Filled PTFE O-Ring ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Bolting Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L4 (8) Austenitic 316 SST Bolts ★<br />

L5 (2)(8)<br />

ASTM A 193, Grade B7M Bolts ★<br />

L6 (8)<br />

Alloy K-500 Bolts ★<br />

L7 (2)(8) ASTM A 453, Class D, Grade 660 Bolts ★<br />

L8 (8) ASTM A 193, Class 2, Grade B8M Bolts ★<br />

Display Type (ERS Primary Only)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

M5 (7)<br />

PlantWeb LCD Display ★<br />

M7 (7)<br />

Remote Mount LCD Display <strong>and</strong> Interface, PlantWeb Housing, No Cable, SST Bracket ★<br />

M8 (7) Remote Mount LCD Display <strong>and</strong> Interface, PlantWeb Housing, 50 ft. (15.2 m) Cable, SST Bracket ★<br />

M9 (7) Remote Mount LCD Display <strong>and</strong> Interface, PlantWeb Housing, 100 ft. (30.5 m) Cable, SST Bracket ★<br />

Special Procedures<br />

Pressure Testing<br />

Exp<strong>and</strong>ed<br />

P1 Hydrostatic Testing with Certificate<br />

Special Cleaning<br />

Exp<strong>and</strong>ed<br />

P2 (8) Cleaning for Special Services<br />

P3 (8)<br />

Table 1. 3051SAM Scalable ERS Measurement Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Cleaning for Less than 1 PPM Chlorine/Fluorine<br />

Typical Model Number: 3051SAM 1 S T 2A 2 E11 A 2A<br />

(1) The pressure range should be specified based on the maximum static pressure, not differential pressure.<br />

(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(3) Not available with Pressure Sensor / Module codes T or E.<br />

(4) Tantalum diaphragm material is only available with Pressure Sensor / Module code G.<br />

(5) “Assemble to” items are specified separately <strong>and</strong> require a completed model number.<br />

(6) Consult an Emerson Process Management representative for performance specifications.<br />

(7) Not available with Configuration Type code S.<br />

(8) Not available with Process Connection code A11.<br />

(9) Not available with M20 or G ½ conduit entry size.<br />

(10) The QZ report quantifies the performance of the entire ERS system. One report is provided per ERS system. The QZ option is specified on the Primary<br />

Transmitter (Configuration Type code P).<br />

(11) Silicone fill fluid is st<strong>and</strong>ard.<br />

9


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

10<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> 3051SAL Scalable ERS <strong>Level</strong> Transmitter<br />

• Integrated transmitter <strong>and</strong> remote seal in a single model number<br />

• Variety of process connections including flanged, threaded, <strong>and</strong> hygienic remote seals<br />

• Available with 10-year stability <strong>and</strong> limited 12-year warranty<br />

A 3051SAL Scalable ERS <strong>Level</strong> Transmitter consists of 3 parts. First, specify the transmitter model codes found on<br />

page 10. Then, specify a remote seal found on page 22. Finish the model number by specifying all desired options<br />

on page 12.<br />

ERS Transmitter Model Codes_______page 10 Direct Mount <strong>Seal</strong> Model Codes_______page 22 ERS Options___________page 12<br />

Table 2. 3051SAL Scalable ERS <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Transmitter Type<br />

3051SAL Scalable <strong>Level</strong> Transmitter<br />

Performance Class<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Ultra: 0.065% span accuracy, 100:1 rangedown, 12-year limited warranty ★<br />

2 Classic: 0.065% span accuracy, 100:1 rangedown ★<br />

Configuration Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

P Electronic Remote Sensor - Primary ★<br />

S Electronic Remote Sensor - Secondary ★<br />

Pressure Module Type Pressure Sensor Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

G Coplanar Gage ★<br />

T In-Line Gage ★<br />

E In-Line Absolute ★<br />

Exp<strong>and</strong>ed<br />

A Coplanar Absolute<br />

Pressure Range (5)<br />

Coplanar Gage In-Line Gage In-Line Absolute Coplanar<br />

Absolute<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1A N/A -14.7 to 30 psig<br />

(-1,0 to 2,06 bar)<br />

2A -250 to 250 inH2O<br />

(-623 to 623 mbar)<br />

3A -393 to 1000 inH2O<br />

(-0,98 to 2,49 bar)<br />

4A -14.2 to 300 psig<br />

(-0,98 to 20,7 bar)<br />

5A -14.2 to 2000 psig<br />

(-0,98 to 137,9 bar)<br />

-14.7 to 150 psig<br />

(-1,0 to 10,34 bar)<br />

-14.7 to 800 psig<br />

(-1,0 to 55,2 bar)<br />

-14.7 to 4000 psig<br />

(-1,0 to 275,8 bar)<br />

-14.7 to 10000 psig<br />

(-1,0 to 689,5 bar)<br />

0 to 30 psia<br />

(0 to 2,06 bar)<br />

0 to 150 psia<br />

(0 to 10,34 bar)<br />

0 to 800 psia<br />

(0 to 55,2 bar)<br />

0 to 4000 psia<br />

(0 to 275,8 bar)<br />

0 to 10000 psia<br />

(0 to 689 bar)<br />

0 to 30 psia<br />

★<br />

(0 to 2,06 bar)<br />

0 to 150 psia ★<br />

(0 to 10,34 bar)<br />

0 to 800 psia ★<br />

(0 to 55,2 bar)<br />

0 to 4000 psia ★<br />

(0 to 275,8 bar)<br />

N/A ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 2. 3051SAL Scalable ERS <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Transmitter Output<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 4-20 mA with Digital Signal Based on HART Protocol ★<br />

Housing Style Material Conduit Entry Size<br />

St<strong>and</strong>ard<br />

Housings for ERS Primary - Configuration Type code P<br />

St<strong>and</strong>ard<br />

1A PlantWeb Housing Aluminum<br />

1<br />

/2–14 NPT ★<br />

1B PlantWeb Housing Aluminum M20 x 1.5 (CM 20) ★<br />

1J PlantWeb Housing SST<br />

1<br />

/2–14 NPT ★<br />

1K PlantWeb Housing SST M20 x 1.5 (CM 20) ★<br />

2E Junction Box with Remote Display<br />

Output<br />

Aluminum<br />

1<br />

/2–14 NPT ★<br />

2F Junction Box with Remote Display<br />

Output<br />

Aluminum M20 x 1.5 (CM 20) ★<br />

2M Junction Box with Remote Display<br />

Output<br />

SST 1 /2–14 NPT ★<br />

Housings for ERS Secondary - Configuration Type code S<br />

2A Junction Box Aluminum<br />

1<br />

/2–14 NPT ★<br />

2B Junction Box Aluminum M20 x 1.5 (CM 20) ★<br />

2J<br />

Exp<strong>and</strong>ed<br />

Junction Box SST<br />

1<br />

/2–14 NPT ★<br />

Housings for ERS Primary - Configuration Type code P<br />

1C PlantWeb Housing Aluminum G1 /2<br />

1L PlantWeb Housing SST G 1 /2<br />

2G Junction Box with Remote Display<br />

Output<br />

Aluminum G1 /2<br />

Housings for ERS Secondary - Configuration Type code S<br />

2C Junction Box Aluminum G1 /2<br />

<strong>Seal</strong> System Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Direct-Mount <strong>Seal</strong> System ★<br />

Direct-Mount Extension (Between Transmitter Flange <strong>and</strong> <strong>Seal</strong>)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 No Extension ★<br />

2 2-in. (50 mm) Extension ★<br />

4 4-in. (100 mm) Extension ★<br />

5 Thermal Optimizer ★<br />

Transmitter Reference Pressure Connection<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

00 None (In-Line Style Sensor) ★<br />

20 316L SST Isolator / SST Transmitter Flange ★<br />

30 Alloy C-276 Isolator / SST Transmitter Flange ★<br />

11


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

<strong>Seal</strong> Fill Fluid Specific<br />

Gravity<br />

at 77 °F<br />

(25 °C)<br />

No Extension 2-in. (50 mm)<br />

Extension<br />

Temperature Limits (1)<br />

4-in. (100 mm)<br />

Extension<br />

Continue specifying a completed model number by choosing a remote seal type below:<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 2. 3051SAL Scalable ERS <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Thermal<br />

Optimizer<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Syltherm XLT 0.85 -102 to 293 °F -102 to 293 °F -102 to 293 °F -102 to 293 °F ★<br />

(-75 to 145 °C) (-75 to 145 °C) (-75 to 145 °C) (-75 to 145 °C)<br />

C Silicone 704 1.07 32 to 401 °F (2)<br />

32 to 464 °F<br />

(0 to 205 °C)<br />

(2)<br />

32 to 500 °F<br />

(0 to 240 °C)<br />

(2)<br />

32 to 599 °F<br />

★<br />

(0 to 260 °C) (0 to 315 °C)<br />

D Silicone 200 0.93 -49 to 401 °F -49 to 401 °F -49 to 401 °F -49 to 401 °F ★<br />

(-45 to 205 °C) (-45 to 205 °C) (-45 to 205 °C) (-45 to 205 °C)<br />

H Inert (Halocarbon) 1.85 -49 to 320 °F -49 to 320 °F -49 to 320 °F -49 to 320 °F ★<br />

(-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C)<br />

G (3)(4) Glycerin <strong>and</strong> Water 1.13 5 to 203 °F 5 to 203 °F 5 to 203 °F 5 to 203 °F<br />

★<br />

(-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C)<br />

N (3) Neobee M-20 0.92 5 to 401 °F (2) 5 to 437 °F 5 to 437 °F 5 to 437 °F<br />

★<br />

(-15 to 205 °C) (-15 to 225 °C) (-15 to 225 °C) (-15 to 225 °C)<br />

P (3)(4)<br />

Propylene Glycol <strong>and</strong> Water 1.02 5 to 203 °F 5 to 203 °F 5 to 203 °F 5 to 203 °F<br />

★<br />

(-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C)<br />

page 22 FF Flush Flanged <strong>Seal</strong> Process Connections:<br />

2 in. / DN 50 / 50A<br />

3 in. / DN 80 / 80A<br />

4 in. / DN 100 / 100A<br />

page 24 EF Extended Flanged <strong>Seal</strong> Process Connections:<br />

3 in. / DN 80 / 80A<br />

4 in. / DN 100 / 100A<br />

page 25 RF Remote Flanged <strong>Seal</strong> Process Connections:<br />

1 in. / DN 25 / 25A<br />

1.5 in. / DN 40 / 40A<br />

page 27 RT Remote Threaded <strong>Seal</strong> Process Connections:<br />

¼ - 18 NPT<br />

½ - 14 NPT<br />

¾ - 14 NPT<br />

1 – 11.5 NPT<br />

page 29 SC Hygienic Tri-Clamp <strong>Seal</strong> Process Connections:<br />

1.5 in.<br />

2 in.<br />

3 in.<br />

page 30 SS Hygienic Tank Spud <strong>Seal</strong> Process Connections:<br />

4 in.<br />

(1)(2) (3) (4)<br />

Options (Include with selected model number)<br />

Electronic Remote Sensor Connection Cable<br />

St<strong>and</strong>ard<br />

12<br />

(5) St<strong>and</strong>ard<br />

R05 50 ft. (15.2 m) Spool of Electronic Remote Sensor Cable ★<br />

R10 100 ft. (30.5 m) Spool of Electronic Remote Sensor Cable ★<br />

R15 150ft. (45.7m) Spool of Electronic Remote Sensor Cable ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Software Configuration<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C1 (6) Custom Software Configuration (Requires Configuration Data Sheet) ★<br />

Gage Pressure Calibration<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C3<br />

Alarm Limit<br />

Gage Pressure Calibration on <strong>Rosemount</strong> 3051SAL_ _A4 only ★<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C4 (6) NAMUR Alarm <strong>and</strong> Saturation <strong>Level</strong>s, High Alarm ★<br />

C5 (6) NAMUR Alarm <strong>and</strong> Saturation <strong>Level</strong>s, Low Alarm ★<br />

C6 (6) Custom Alarm <strong>and</strong> Saturation <strong>Level</strong>s, High Alarm (Requires C1 <strong>and</strong> Configuration Data Sheet) ★<br />

C7 (6)<br />

Custom Alarm <strong>and</strong> Saturation <strong>Level</strong>s, Low Alarm (Requires C1 <strong>and</strong> Configuration Data Sheet) ★<br />

C8 (6)<br />

Low Alarm (St<strong>and</strong>ard <strong>Rosemount</strong> Alarm <strong>and</strong> Saturation <strong>Level</strong>s) ★<br />

Ground Screw<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D4 External Ground Screw Assembly ★<br />

Conduit Plug<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

DO 316 SST Conduit Plug ★<br />

Product Certifications<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

E1 ATEX Flameproof ★<br />

I1 ATEX Intrinsic Safety ★<br />

N1 ATEX Type n ★<br />

K1 ATEX Flameproof <strong>and</strong> Intrinsically Safe, Type n, Dust ★<br />

ND ATEX Dust ★<br />

E4 TIIS Flameproof ★<br />

E5 FM Explosion-proof, Dust Ignition-proof ★<br />

I5 FM Intrinsically Safe, Division 2 ★<br />

K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

E6 (7) CSA Explosion-proof, Dust Ignition-proof, Division 2 ★<br />

I6 CSA Intrinsically Safe ★<br />

K6 (7) CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

E7 IECEx Flameproof ★<br />

I7 IECEx Intrinsic Safety ★<br />

N7 IECEx Type n ★<br />

K7 IECEx Flameproof, Intrinsic Safety, Type n ★<br />

E2 INMETRO Flameproof ★<br />

I2 INMETRO Intrinsically Safe ★<br />

K2 INMETRO Flameproof, Intrinsic Safety, Type n ★<br />

KA (7)<br />

ATEX <strong>and</strong> CSA Flameproof, Intrinsically Safe, Division 2 ★<br />

KB (7)<br />

FM <strong>and</strong> CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

KC FM <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe, Division 2 ★<br />

KD (7) FM, CSA, <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe ★<br />

Sensor Fill Fluid<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L1 (8)<br />

Inert Sensor Fill Fluid ★<br />

O-Ring<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L2 Graphite-filled PTFE o-ring ★<br />

13


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

14<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Bolting Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L4 Austenitic 316 SST Bolts ★<br />

L5 (9) ASTM A 193, Grade B7M Bolts ★<br />

L6 Alloy K-500 Bolts ★<br />

L7 (9)<br />

ASTM A 453, Class D, Grade 660 Bolts ★<br />

L8 ASTM A 193, Class 2, Grade B8M Bolts ★<br />

Display Type (ERS Primary Only)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

M5 (6) PlantWeb LCD Display ★<br />

M7 (6) Remote Mount LCD Display <strong>and</strong> Interface, PlantWeb Housing, No Cable, SST Bracket ★<br />

M8 (6)<br />

Remote Mount LCD Display <strong>and</strong> Interface, PlantWeb Housing, 50 ft. (15.2 m) Cable, SST Bracket ★<br />

M9 (6)<br />

Remote Mount LCD Display <strong>and</strong> Interface, PlantWeb Housing, 100 ft. (30.5 m) Cable, SST Bracket ★<br />

Special Procedures<br />

Pressure Testing<br />

Exp<strong>and</strong>ed<br />

P1 Hydrostatic Testing with Certificate<br />

Special Cleaning<br />

Exp<strong>and</strong>ed<br />

P2 Cleaning for Special Services<br />

P3 Cleaning for Less than 1 PPM Chlorine/Fluorine<br />

Special Certifications<br />

Calibration Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q4 Calibration Certificate ★<br />

QP Calibration certificate with tamper evident seal ★<br />

Material Traceability Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q8 Material traceability certification per EN 10204 3.1 ★<br />

Quality Certification for Safety<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QS Prior-use certificate of FMEDA Data ★<br />

Toolkit Performance Reports<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QZ (10)<br />

Remote <strong>Seal</strong> System Performance Calculation Report ★<br />

Transient Protection<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T1 (6) Transient Terminal Block ★<br />

Typical Model Number: 3051SAL 1 P G 4A A 1A 1 0 20 D FF 7 1 DA 0 0 M5<br />

(1) At ambient pressure of 14.7 psia (1 bar-a) <strong>and</strong> ambient temperature of 70°F (21°C). Temperature limits are reduced in vacuum service <strong>and</strong> may be limited<br />

by seal selection.<br />

(2) Maximum process temperature is limited by heat transfer to the transmitter electronics <strong>and</strong> must be further derated if ambient, temperature exceeds 70 °F<br />

(21 °C).<br />

(3) This is a food grade fill fluid.<br />

(4) Not suitable for vacuum applications.<br />

(5) The pressure range should be specified based on the maximum static pressure, not differential pressure.<br />

(6) Not available with Configuration Type code S.<br />

(7) Not available with M20 or G ½ conduit entry size.<br />

(8) Silicone fill fluid is st<strong>and</strong>ard.<br />

(9) Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(10) The QZ report quantifies the performance of the entire ERS system. One report is provided per ERS system. The QZ option is specified on the Primary<br />

Transmitter (Configuration Type code P).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter<br />

3051SAL In-Line with<br />

“FF” Flanged <strong>Seal</strong><br />

3051SAL Coplanar<br />

with “SS” Hygienic<br />

Tank Spud <strong>Seal</strong><br />

Tuned-System<br />

Assembly Comprised<br />

of 3051SAL with<br />

<strong>1199</strong> Flanged <strong>Seal</strong><br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> <strong>Transmitters</strong> combine the features <strong>and</strong><br />

benefits of a high-performance 3051S pressure transmitter with the durability<br />

<strong>and</strong> reliability of a direct mount seal all in a single model number.<br />

<strong>Level</strong> transmitters can also be ordered with an additional <strong>1199</strong> Remote Mount<br />

<strong>Seal</strong> to form a Tuned-System Assembly that offers improved performance <strong>and</strong><br />

reduced costs compared to traditional symmetrical (balanced) assemblies.<br />

Product features <strong>and</strong> capabilities include:<br />

• Variety of process connections including flanged, threaded, <strong>and</strong> hygienic<br />

seals<br />

• Quantified performance for the entire transmitter / seal assembly (QZ option)<br />

• HART, FOUNDATION fieldbus, <strong>and</strong> Wireless protocols<br />

Additional Information<br />

Specifications: page 100<br />

Dimensional Drawings: page 114<br />

<strong>Rosemount</strong> 3051SAL Scalable <strong>Level</strong> Transmitter<br />

A 3051SAL Scalable <strong>Level</strong> Transmitter consists of 3 parts. First, specify the transmitter model codes found on<br />

page 15. Then, specify a remote seal found on page 22. Finish the model number by specifying all desired options on<br />

page 18.<br />

Transmitter Model Codes_.................._ page 15 Direct Mount <strong>Seal</strong> Model Codes_........._page 22 Transmitter Options......... page 18<br />

Table 3. <strong>Rosemount</strong> 3051SAL Scalable <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Transmitter Type<br />

3051SAL Scalable <strong>Level</strong> Transmitter<br />

Performance Class<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Ultra: 0.065% span accuracy, 100:1 rangedown, 12-year limited warranty ★<br />

2 Classic: 0.065% span accuracy, 100:1 rangedown ★<br />

Configuration Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C Liquid <strong>Level</strong> Transmitter ★<br />

Pressure Module Type Pressure Sensor Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D Coplanar Differential ★<br />

G Coplanar Gage ★<br />

T In-Line Gage ★<br />

E In-Line Absolute ★<br />

15


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

16<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 3. <strong>Rosemount</strong> 3051SAL Scalable <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Exp<strong>and</strong>ed<br />

A Coplanar Absolute<br />

Pressure Range<br />

Coplanar <strong>DP</strong> Coplanar Gage In-Line Gage In-Line Absolute Coplanar Absolute<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1A N/A N/A -14.7 to 30 psig 0 to 30 psia 0 to 30 psia<br />

★<br />

(-1,0 to 2,06 bar) (0 to 2,06 bar) (0 to 2,06 bar)<br />

2A -250 to 250 inH2O -250 to 250 inH2O -14.7 to 150 psig 0 to 150 psia 0 to 150 psia<br />

★<br />

(-623 to 623 mbar) (-623 to 623 mbar) (-1,0 to 10,3 bar) (0 to 10,34 bar) (0 to 10,34 bar)<br />

3A -1000 to 1000 inH2O -393 to 1000 inH2O -14.7 to 800 psig 0 to 800 psia 0 to 800 psia<br />

★<br />

(-2,5 to 2,5 bar) (-0,98 to 2,5 bar) (-1,0 to 55,2 bar) (0 to 55,2 bar) (0 to 55,2 bar)<br />

4A -300 to 300 psi<br />

-14.2 to 300 psig -14.7 to 4000 psig 0 to 4000 psia 0 to 4000 psia<br />

★<br />

(-20,7 to 20,7 bar) (-0,98 to 20,7 bar) (-1,0 to 275,8 bar) (0 to 275,8 bar) (0 to 275,8 bar)<br />

5A -2000 to 2000 psi -14.2 to 2000 psig -14.7 to 10000 psig 0 to 10000 psia N/A ★<br />

(-137,9 to 137,9 bar) (-0,98 to 137,9 bar) (-1,0 to 689 bar) (0 to 689 bar)<br />

Transmitter Output (2)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 4-20 mA with digital signal based on HART protocol ★<br />

F (11) FOUNDATION fieldbus protocol ★<br />

X (12)<br />

Wireless (Requires wireless options <strong>and</strong> wireless PlantWeb housing) ★<br />

Housing Style Material (18)<br />

Conduit Entry<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1A PlantWeb housing Aluminum<br />

1<br />

/2–14 NPT ★<br />

1B PlantWeb housing Aluminum M20 x 1.5 ★<br />

1J PlantWeb housing SST 1 /2–14 NPT ★<br />

1K PlantWeb housing SST M20 x 1.5 ★<br />

2A Junction Box housing Aluminum 1 /2–14 NPT ★<br />

2B Junction Box housing Aluminum M20 x 1.5 ★<br />

2E Junction Box with output for remote interface Aluminum<br />

1<br />

/2–14 NPT ★<br />

2F Junction Box with output for remote interface Aluminum M20 x 1.5 ★<br />

2J Junction Box housing SST<br />

1<br />

/2–14 NPT ★<br />

5A (6) Wireless PlantWeb housing Aluminum 1 /2–14 NPT ★<br />

5J (6) Wireless PlantWeb housing SST 1 /2–14 NPT ★<br />

7J (13)<br />

Exp<strong>and</strong>ed<br />

Quick Connect (A size Mini, 4-pin male<br />

termination)<br />

SST ★<br />

1C PlantWeb housing Aluminum G1 /2<br />

1L PlantWeb housing 316L SST G1 /2<br />

2C Junction Box housing Aluminum G 1 /2<br />

2G Junction Box with output for remote interface Aluminum G1 /2<br />

Direct-Mount Extension (Between Transmitter Flange <strong>and</strong> <strong>Seal</strong>)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

10 No Extension ★<br />

12 2-in. (50 mm) Extension ★<br />

14 4-in. (100 mm) Extension ★<br />

15 (5) Thermal Optimizer ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Transmitter Reference Pressure Connection<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 3. <strong>Rosemount</strong> 3051SAL Scalable <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

00 None (Inline Module Type Only) ★<br />

10<br />

Continue specifying a completed model number by choosing a remote seal type below:<br />

(14) Tuned-System Assembly, One Capillary Remote <strong>Seal</strong> (Requires separate <strong>1199</strong> model number) ★<br />

20 316 L SST Isolator with SST Transmitter Flange ★<br />

30 Alloy C-276 Isolator with SST Transmitter Flange<br />

Temperature Limits<br />

★<br />

<strong>Seal</strong> Fill Fluid<br />

Specific Gravity at<br />

77 °F (25 °C)<br />

(1)<br />

No Extension<br />

2-in. (50 mm)<br />

Extension<br />

4-in. (100 mm)<br />

Extension<br />

Thermal<br />

Optimizer<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Syltherm XLT 0.85 -102 to 293 °F -102 to 293 °F 102 to 293 °F 102 to 293 °F ★<br />

(-75 to 145 °C) (-75 to 145 °C) (-75 to 145 °C) (-75 to 145 °C)<br />

C Silicone 704 1.07 32 to 401 °F<br />

(0 to 205 °C) (2)<br />

32 to 464 °F<br />

(0 to 240 °C) (2)<br />

32 to 500 °F<br />

(0 to 260 °C) (2)<br />

32 to 599 °F ★<br />

(0 to 315 °C)<br />

D Silicone 200 0.93 -49 to 401 °F -49 to 401 °F -49 to 401 °F -49 to 401 °F ★<br />

(-45 to 205 °C) (-45 to 205 °C) (-45 to 205 °C) (-45 to 205 °C)<br />

H Inert (Halocarbon) 1.85 -49 to 320 °F -49 to 320 °F -49 to 320 °F -49 to 320 °F ★<br />

(-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C)<br />

G (3)(4) Glycerine <strong>and</strong> Water 1.13 5 to 203 °F 5 to 203 °F 5 to 203 °F 5 to 203 °F ★<br />

(-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C)<br />

N (3)<br />

Neobee M-20 0.92 5 to 401 °F<br />

(-15 to 205 °C) (2)<br />

5 to 437 °F 5 to 437 °F 5 to 437 °F ★<br />

(-15 to 225 °C) (-15 to 225 °C) (-15 to 225 °C)<br />

P (3)(4) Propylene Glycol <strong>and</strong> 1.02 5 to 203 °F 5 to 203 °F 5 to 203 °F 5 to 203 °F ★<br />

Water<br />

(-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C)<br />

page 22 FF Flush Flanged <strong>Seal</strong> Process Connections:<br />

2 in. / DN 50 / 50A<br />

3 in. / DN 80 / 80A<br />

4 in. / DN 100 / 100A<br />

page 24 EF Extended Flanged <strong>Seal</strong> Process Connections:<br />

3 in. / DN 80 / 80A<br />

4 in. / DN 100 / 100A<br />

page 25 RF Remote Flanged <strong>Seal</strong> Process Connections:<br />

1 in. / DN 25 / 25A<br />

1.5 in. / DN 40 / 40A<br />

page 27 RT Remote Threaded <strong>Seal</strong> Process Connections:<br />

¼ - 18 NPT<br />

½ - 14 NPT<br />

¾ - 14 NPT<br />

1 – 11.5 NPT<br />

page 29 SC Hygienic Tri-Clamp <strong>Seal</strong> Process Connections:<br />

1.5 in.<br />

2 in.<br />

3 in.<br />

page 30 SS Hygienic Tank Spud <strong>Seal</strong> Process Connections:<br />

4 in.<br />

17


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

18<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Wireless Options (1)(2) (3) (4)(5)<br />

(Requires option code X <strong>and</strong> wireless PlantWeb housing)<br />

Update Rate<br />

St<strong>and</strong>ard (6)<br />

St<strong>and</strong>ard<br />

WA User Configurable Update Rate ★<br />

Operating Frequency <strong>and</strong> Protocol<br />

St<strong>and</strong>ard (7)<br />

St<strong>and</strong>ard<br />

3 2.4 GHz DSSS, IEC 62591 (WirelessHART) ★<br />

Omnidirectional Wireless Antenna<br />

St<strong>and</strong>ard (8)<br />

St<strong>and</strong>ard<br />

WK External Antenna ★<br />

WM<br />

Exp<strong>and</strong>ed<br />

Extended Range, External Antenna ★<br />

WN<br />

SmartPower<br />

High-Gain, Remote Antenna<br />

<br />

St<strong>and</strong>ard (9)<br />

St<strong>and</strong>ard<br />

1 (10) Adapter for Black Power Module (I.S. Power Module Sold Separately) ★<br />

Other Options (Include with selected model number)<br />

PlantWeb Control Functionality<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A01 (11)(12) FOUNDATION fieldbus Advanced Control Function Block Suite ★<br />

Hardware Adjustments<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D01 (11)(12) FOUNDATION fieldbus Diagnostics Suite ★<br />

DA2 (13)<br />

Advanced HART Diagnostics Suite ★<br />

Software Configuration<br />

St<strong>and</strong>ard (14) St<strong>and</strong>ard<br />

C1 (15)<br />

Custom software configuration (Requires Configuration Data Sheet) ★<br />

Gage Pressure Calibration<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C3<br />

Alarm Limit<br />

Gage pressure calibration on <strong>Rosemount</strong> 3051SAL_ _A4 only ★<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C4 (11)(15)<br />

NAMUR alarm <strong>and</strong> saturation levels, high alarm ★<br />

C5 (11)(15) NAMUR alarm <strong>and</strong> saturation levels, low alarm ★<br />

C6 (11)(15) Custom alarm <strong>and</strong> saturation signal levels, high alarm (Requires C1 <strong>and</strong> Configuration Data Sheet) ★<br />

C7 (11)(15)<br />

Custom alarm <strong>and</strong> saturation signal levels, low alarm (Requires C1 <strong>and</strong> Configuration Data Sheet) ★<br />

C8 (11)(15) Low alarm (st<strong>and</strong>ard <strong>Rosemount</strong> alarm <strong>and</strong> saturation levels) ★<br />

Hardware Adjustments<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D1 (11)(15)(16) Hardware adjustments (zero, span, alarm, security) ★<br />

Flange Adapter<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D2<br />

Exp<strong>and</strong>ed<br />

1 /2-14 NPT flange adapter ★<br />

D9 RC 1 Ground Screw<br />

/2 SST flange adapter ★<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D4 External ground screw assembly ★<br />

Drain/Vent Valve<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D5<br />

Conduit Plug<br />

Delete transmitter drain/vent valves (install plugs) ★<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

DO (17)<br />

316 SST Conduit Plug ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Product Certifications (18)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

E1 ATEX Flameproof ★<br />

I1 ATEX Intrinsic Safety ★<br />

IA ATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only) ★<br />

N1 ATEX Type n ★<br />

K1 ATEX Flameproof, Intrinsic Safety, Type n, Dust ★<br />

ND ATEX Dust ★<br />

E4 TIIS Flameproof ★<br />

E5 FM Explosion-proof, Dust Ignition-proof ★<br />

I5 FM Intrinsically Safe, Division 2 ★<br />

IE FM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only) ★<br />

K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

E6 (19) CSA Explosion-proof, Dust Ignition-proof, Division 2 ★<br />

I6 CSA Intrinsically Safe ★<br />

IF CSA FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only) ★<br />

K6 (19) CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

D3 (20)<br />

Measurement Canada Accuracy Approval ★<br />

E7 IECEx Flameproof, Dust Ignition-proof ★<br />

I7 IECEx Intrinsic Safety ★<br />

IG IECEx FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only) ★<br />

N7 IECEx Type n ★<br />

K7 IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n ★<br />

E2 INMETRO Flameproof ★<br />

I2 INMETRO Intrinsic Safety ★<br />

K2 INMETRO Flameproof, Intrinsic Safety ★<br />

E3 China Flameproof ★<br />

I3 China Intrinsic Safety, Dust Ignition-proof ★<br />

KA (19) ATEX <strong>and</strong> CSA Flameproof, Intrinsically Safe, Division 2 ★<br />

KB (19) FM <strong>and</strong> CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

KC FM <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe, Division 2 ★<br />

KD (19) FM, CSA, <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe ★<br />

Sensor Fill Fluid<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L1 (21) Inert sensor fill fluid ★<br />

O-Ring<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L2 Graphite-filled PTFE o-ring ★<br />

Bolting Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L4 Austenitic 316 SST bolts ★<br />

L5 (22) ASTM A193, Grade B7M bolts ★<br />

L6 Alloy K-500 bolts ★<br />

L7 (22) ASTM A453, Class D, Grade 660 bolts ★<br />

L8 ASTM A193, Class 2, Grade B8M bolts ★<br />

Display Type (23)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

M5 PlantWeb LCD Display ★<br />

M7 (11)<br />

Remote mount LCD display <strong>and</strong> interface, PlantWeb housing, no cable, SST bracket ★<br />

M8 (11) Remote mount LCD display <strong>and</strong> interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket ★<br />

M9 (11) Remote mount LCD display <strong>and</strong> interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket ★<br />

Pressure Testing<br />

Exp<strong>and</strong>ed<br />

P1 Hydrostatic testing with certificate<br />

19


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

20<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Special Cleaning<br />

Exp<strong>and</strong>ed<br />

P2 Cleaning for special services<br />

P3 Cleaning for less than 1PPM Chlorine/Fluorine<br />

Calibration Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q4 Calibration certificate ★<br />

QP Calibration certificate <strong>and</strong> tamper evident seal ★<br />

Material Traceability Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q8 Material traceability certification per EN 10204 3.1 ★<br />

Quality Certification for Safety<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QS (11)(15) Prior-use certificate of FMEDA Data ★<br />

QT (24)<br />

Safety-certified to IEC 61508 with certificate of FMEDA data ★<br />

Toolkit Performance Reports<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QZ Remote <strong>Seal</strong> System Performance Calculation Report ★<br />

Transient Protection<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T1 (25)(26) Transient terminal block ★<br />

Conduit Electrical Connector<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

GE (27) M12, 4-pin, Male Connector (eurofast ® ) ★<br />

GM (27)<br />

A size Mini, 4-pin, Male Connector (minifast ® ) ★<br />

Typical Model Number: 3051SAL 1 C G 2A A 1A 10 20 D FF G 1 DA 0 0<br />

(1) At ambient pressure of 14.7 psia (1 bar-a) <strong>and</strong> ambient temperature of 70°F (21°C). Temperature limits are reduced in vacuum service <strong>and</strong> may be limited<br />

by seal selection.<br />

(2) Maximum process temperature is limited by heat transfer to the transmitter <strong>and</strong> must be further derated if ambient, temperature exceeds 70 °F (21 °C).<br />

See “Fill Fluid Specifications” on page 94 for more information.<br />

(3) This is a food grade fill fluid.<br />

(4) Not suitable for vacuum applications.<br />

(5) Only available with in-line style gage <strong>and</strong> absolute transmitters (Option codes T <strong>and</strong> E).<br />

(6) Only available with output code X.<br />

(7) Long-Life Power Module must be shipped separately, order Part #00753-9220-0001.<br />

(8) Only available with output code X.<br />

(9) Not available with output code A.<br />

(10) Requires PlantWeb housing <strong>and</strong> Output code A. Includes Hardware Adjustments as st<strong>and</strong>ard.<br />

(11) Requires PlantWeb housing.<br />

(12) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1),<br />

<strong>and</strong> IECEx Intrinsic Safety (option code I7).<br />

(13) Available with output code A only. Available approvals are FM Intrinsically Safe, Division 2 (option code I5), ATEX Intrinsic Safety (option code I1), or IECEx<br />

Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.<br />

(14) With option code 10, user must select <strong>Seal</strong> Location option code M in Table 7 of <strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong> PDS.<br />

(15) Not available with output code F.<br />

(16) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of carbon steel conduit plug.<br />

(17) Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.<br />

(18) Valid when SuperModule Platform <strong>and</strong> housing have equivalent approvals.<br />

(19) Not available with M20 or G ½ conduit entry size.<br />

(20) Requires PlantWeb housing <strong>and</strong> Hardware Adjustments option code D1. Limited availability depending on transmitter type <strong>and</strong> range. Contact an Emerson<br />

Process Management representative for additional information.<br />

(21) Silicone fill fluid is st<strong>and</strong>ard.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

(22) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(23) Not available with Housing code 01 or 7J.<br />

(24) Not available with output code F or X. Not available with housing code 01 or 7J.<br />

(25) Not available with Housing code 00, 01, 5A, or 7J.<br />

(26) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, <strong>and</strong> IG.<br />

(27) Not available with Housing code 00, 01, 5A, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or<br />

FM FISCO Intrinsically Safe (option code IE), install in accordance with <strong>Rosemount</strong> drawing 03151-1009 to maintain outdoor rating (NEMA 4X <strong>and</strong> IP66).<br />

21


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

22<br />

Direct Mount <strong>Seal</strong>s for 3051SAL<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Flush Flanged (FF) <strong>Seal</strong><br />

• Most common seal<br />

• Good for use in general applications<br />

• Easy installation on flanged connections ranging from 2-in. (DN 50) to 4-in. (DN 100)<br />

Table 4. Flush Flanged (FF) <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Process Connection<br />

FF Flush Flanged <strong>Seal</strong><br />

Process Connection Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

G 2-in. / DN 50 / 50A ★<br />

7 3-in. / 80A ★<br />

J DN 80 ★<br />

9 4-in. / DN 100 / 100A ★<br />

Flange / Pressure Rating<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 ANSI/ASME B16.5 Class 150 ★<br />

2 ANSI/ASME B16.5 Class 300 ★<br />

4 ANSI/ASME B16.5 Class 600 ★<br />

G<br />

Exp<strong>and</strong>ed<br />

PN 40 per EN 1092-1 ★<br />

A 10K per JIS B2238<br />

B 20K per JIS B2238<br />

D 40K per JIS B2238<br />

E PN 10/16 per EN 1092-1, Available with DN 100 only<br />

Materials of Construction<br />

Isolating Diaphragm Upper Housing Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

CA 316L SST 316L SST CS ★<br />

DA 316L SST 316L SST 316 SST ★<br />

CB (1) Alloy C-276 316L SST CS ★<br />

DB (1)<br />

Alloy C-276 316L SST 316 SST ★<br />

CC Tantalum 316L SST CS ★<br />

DC Tantalum 316L SST 316 SST ★<br />

Flushing Connection Ring (Lower Housing) (2)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 None ★<br />

A 316 SST ★<br />

B Alloy C-276 ★<br />

Flushing Connection Quantity & Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 None ★<br />

1 One 1 /4-18 NPT Flushing Connection ★<br />

3 Two 1 /4-18 NPT Flushing Connections ★<br />

7 One 1 /2-14 NPT Flushing Connection ★<br />

9 Two 1 /2-14 NPT Flushing Connections ★<br />

Options (Include with selected model number)<br />

Cold Temperature Remote <strong>Seal</strong> Applications<br />

Exp<strong>and</strong>ed<br />

SB Extra Fill Fluid for Cold Temperature Applications


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Remote <strong>Seal</strong> Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

SC (3) 0.006-in. (150 μm) Diaphragm Thickness<br />

Flushing Connection Ring Plugs<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SD Alloy C-276 Plug(s) for Flushing Connection(s) ★<br />

SG SST Plug(s) for Flushing Connection(s) ★<br />

SH SST Drain / Vent(s) for Flushing Connection(s) ★<br />

Flushing Connection Ring Gaskets<br />

Exp<strong>and</strong>ed<br />

SJ PTFE Gasket<br />

SK Barium Sulfate-Filled PTFE Gasket<br />

SN Grafoil Gasket<br />

Additional Options<br />

Remote <strong>Seal</strong> Code Conformance<br />

Exp<strong>and</strong>ed<br />

ST (4) Wetted Material Compliance per NACE MR 0175 / ISO 15156, MR 0103<br />

Remote <strong>Seal</strong> Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

SU (3) 0.001-in. ±0.0002-in. (25 μm ±5 μm) Gold Plated Diaphragm<br />

SV (5) Table 4. Flush Flanged (FF) <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

PTFE Coated Diaphragm for Non-Stick Purposes<br />

Complete the 3051SAL model number by specifying options as needed:<br />

page 12 ERS Transmitter Options<br />

page 18 Scalable <strong>Level</strong> Transmitter Options<br />

(1) Not available with option code SC.<br />

(2) Supplied with Thermo Tork TN9000 gasket.<br />

(3) Not available with Tantalum diaphragms (Material of Construction codes CC <strong>and</strong> DC).<br />

(4) Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(5) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)<br />

23


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Extended Flanged (EF) <strong>Seal</strong><br />

• Good for use in viscous applications with plugging issues<br />

• <strong>Seal</strong> diaphragm installed flush with inner tank wall to prevent process plugging<br />

• Easy installation on 3-in. (DN 80) <strong>and</strong> 4-in. (DN 100) flanged connections<br />

(2) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)<br />

24<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 5. Extended Flanged (EF) <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Process Connection<br />

EF Extended Flanged <strong>Seal</strong><br />

Process Connection Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

7 3-in. / DN 80 / 80A ★<br />

9 4-in. / DN 100 / 100A ★<br />

Flange / Pressure Rating<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 ANSI/ASME B16.5 Class 150 ★<br />

2 ANSI/ASME B16.5 Class 300 ★<br />

4 ANSI/ASME B16.5 Class 600 ★<br />

G PN 40 per EN 1092-1 ★<br />

Exp<strong>and</strong>ed<br />

A 10K per JIS B2238<br />

B 20K per JIS B2238<br />

D 40K per JIS B2238<br />

E PN 10/16 per EN 1092-1, Available with DN 100 only<br />

Materials of Construction<br />

Isolating Diaphragm Extension / Gasket Surface Mounting Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

CA 316L SST 316L SST CS ★<br />

DA 316L SST 316L SST 316 SST ★<br />

CB Alloy C-276 Alloy C-276 CS ★<br />

DB Alloy C-276 Alloy C-276 316 SST ★<br />

<strong>Seal</strong> Extension Length<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

20 2-in. (50 mm) ★<br />

40 4-in. (100 mm) ★<br />

60 6-in. (150 mm) ★<br />

Options (Include with selected model number)<br />

Cold Temperature Remote <strong>Seal</strong> Applications<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SB Extra Fill Fluid for Cold Temperature Applications ★<br />

Remote <strong>Seal</strong> Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

SC 0.006-in. (150 μm) Diaphragm Thickness<br />

Remote <strong>Seal</strong> Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

ST (1)<br />

Wetted Material Compliance per NACE MR 0175 / ISO 15156, MR 0103 ★<br />

Remote <strong>Seal</strong> Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

SU 0.001-in. ±0.0002-in. (25 μm ±5 μm) Gold Plated Diaphragm<br />

SV (2) PTFE Coated Diaphragm for Non-Stick Purposes<br />

Complete the 3051SAL model number by specifying options as needed:<br />

page 12 ERS Transmitter Options<br />

page 18 Scalable <strong>Level</strong> Transmitter Options<br />

(1) Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Remote Flanged (RF) <strong>Seal</strong><br />

• Designed to improve performance on smaller process connections<br />

• Easy installation on flanged connections ranging from 1-in. to 1.5-in. (DN 50 – DN 40)<br />

• Lower housing / flushing ring required<br />

Table 6. Remote Flanged (RF) <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Process Connection<br />

RF Remote Flanged <strong>Seal</strong><br />

Process Connection Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 1-in. / 25A ★<br />

4 1.5-in. / 40A ★<br />

D DN 25 ★<br />

F DN 40 ★<br />

Flange / Pressure Rating<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 ANSI/ASME B16.5 Class 150 ★<br />

2 ANSI/ASME B16.5 Class 300 ★<br />

4 ANSI/ASME B16.5 Class 600 ★<br />

G PN 40 per EN 1092-1 ★<br />

Exp<strong>and</strong>ed<br />

A 10K per JIS B2238<br />

B 20K per JIS B2238<br />

D 40K per JIS B2238<br />

Materials of Construction<br />

Isolating Diaphragm Upper Housing Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

CA 316L SST 316L SST CS ★<br />

DA 316L SST 316L SST 316 SST ★<br />

CB Alloy C-276 316L SST CS ★<br />

DB Alloy C-276 316L SST 316 SST ★<br />

CC Tantalum 316L SST CS ★<br />

DC Tantalum 316L SST 316 SST ★<br />

Flushing Connection Ring Material (Lower Housing) (1)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 316L SST ★<br />

B Alloy C-276 ★<br />

D Plated CS ★<br />

Number of Flushing Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 One ¼-18 NPT Flushing Connection ★<br />

3 Two ¼-18 NPT Flushing Connections ★<br />

5 None ★<br />

Options (Include with selected model number)<br />

Remote <strong>Seal</strong> Diaphragm Thickness<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SB Extra Fill Fluid for Cold Temperature Applications ★<br />

Remote <strong>Seal</strong> Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

SC (2) 0.006-in. (150 μm) Diaphragm Thickness<br />

Remote <strong>Seal</strong> Flushing Connection Plug, Drain/Vent<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SD Alloy C-276 Plug(s) for Flushing Connection(s) ★<br />

SG 316 SST Plug(s) for Flushing Connection(s) ★<br />

SH 316 SST Drain / Vent(s) for Flushing Connection(s) ★<br />

25


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

26<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Remote <strong>Seal</strong> Gasket Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SJ<br />

Exp<strong>and</strong>ed<br />

PTFE Gasket (for use with Flushing Connection Ring) ★<br />

SK Barium Sulfate-Filled PTFE Gasket (for use with Flushing Connection Ring)<br />

SN Grafoil Gasket (for use with Flushing Connection Ring)<br />

Remote <strong>Seal</strong> Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

ST (3)<br />

Wetted Material Compliance per NACE MR 0175 / ISO 15156, MR 0103 ★<br />

Remote <strong>Seal</strong> Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

SU (2)<br />

0.001-in. ±0.0002-in. (25 μm ±5 μm) Gold Plated Diaphragm<br />

SV (4) Table 6. Remote Flanged (RF) <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

PTFE Coated Diaphragm for Non-Stick Purposes<br />

Complete the 3051SAL model number by specifying options as needed:<br />

page 12 ERS Transmitter Options<br />

page 18 Scalable <strong>Level</strong> Transmitter Options<br />

(1) Supplied with C4401 Aramid fiber gasket.<br />

(2) Not available with Tantalum diaphragms (Material of Construction codes CC <strong>and</strong> DC).<br />

(3) Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(4) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Remote Threaded (RT) <strong>Seal</strong><br />

• For use with threaded process connections ( 1 /4-18 to 1-11.5 NPT)<br />

• Rated for use in high-pressure applications (up to 2500 PSI)<br />

• Optional flushing connections available<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 7. RT Threaded <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

RT Remote Threaded <strong>Seal</strong> ★<br />

Process Connection Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

3 1 /2-14 NPT ★<br />

4 3 /4-14 NPT ★<br />

5<br />

Exp<strong>and</strong>ed<br />

1-11.5 NPT ★<br />

1<br />

1 /4-18 NPT<br />

Pressure Rating<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 2500 psi ★<br />

Isolating Diaphragm Material Upper Housing Material Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

CA 316L SST 316L SST CS ★<br />

DA 316L SST 316L SST 316 SST ★<br />

CB Alloy C-276 316L SST CS ★<br />

DB Alloy C-276 316L SST 316 SST ★<br />

CC Tantalum 316L SST CS ★<br />

DC Tantalum 316L SST 316 SST ★<br />

Flushing Connection Ring Material (Lower Housing) (1) (2)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 316L SST ★<br />

B<br />

Exp<strong>and</strong>ed<br />

Alloy C-276 ★<br />

D Plated CS<br />

Number of Flushing Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 One 1 /4-in. Flushing Connection ★<br />

3 Two 1 /4-in. Flushing Connections ★<br />

5 No Flushing Connection ★<br />

Options (Include with selected model number)<br />

Remote <strong>Seal</strong> Diaphragm Thickness<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SB Extra Fill Fluid for Cold Temperature Applications ★<br />

Remote <strong>Seal</strong> Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

SC (3) 0.006-in. (150 μm) Diaphragm Thickness<br />

Remote <strong>Seal</strong> Flushing Plug, Drain/Vent<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SD Alloy C-276 Plug(s) for Flushing Connection(s) ★<br />

SG 316 SST Plug(s) for Flushing Connection(s) ★<br />

SH 316 SST Drain / Vent(s) for Flushing Connection(s) ★<br />

27


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

28<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Remote <strong>Seal</strong> Gasket Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SJ PTFE Gasket (for use with Flushing Connection Ring) ★<br />

SN Grafoil Gasket (for use with Flushing Connection Ring) ★<br />

SR<br />

Exp<strong>and</strong>ed<br />

Ethylene Propylene Gasket (for use with Flushing Connection Ring) ★<br />

SK Barium Sulfate-Filled PTFE Gasket (for use with Flushing Connection Ring)<br />

Remote <strong>Seal</strong> Bolt<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

S3<br />

Exp<strong>and</strong>ed<br />

304 SST Bolts ★<br />

S4 316 SST Bolts<br />

Remote <strong>Seal</strong> Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

ST (4)<br />

Wetted Material Compliance per NACE MR 0175 / ISO 15156, MR 0103 ★<br />

Remote <strong>Seal</strong> Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

SU (3) 0.001-in. ±0.0002-in. (25 μm ±5 μm) Gold Plated Diaphragm<br />

SV (5)<br />

Table 7. RT Threaded <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

PTFE Coated Diaphragm for Non-Stick Purposes<br />

Complete the 3051SAL model number by specifying options as needed:<br />

page 12 ERS Transmitter Options<br />

page 18 Scalable <strong>Level</strong> Transmitter Options<br />

(1) Supplied with C4401 aramid fiber gasket.<br />

(2) Flushing Connection Ring/ Lower Housing assembly bolts provided as st<strong>and</strong>ard are carbon steel.<br />

(3) Not available with Tantalum diaphragms (Material of Construction codes CC <strong>and</strong> DC).<br />

(4) Materials of construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(5) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Hygienic Tri-Clamp (SC) <strong>Seal</strong><br />

• Good for use in hygienic applications<br />

• Easy installation on Tri-Clover style Tri-Clamp ® connections (1.5-in. to 3-in.)<br />

• Conforms to 3-A st<strong>and</strong>ard 74-03<br />

Table 8. SC Hygienic Tri-Clover Style Tri-Clamp <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Process Connection<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SC (1)<br />

Tri-Clover Style Tri-Clamp <strong>Seal</strong> ★<br />

Process Connection Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

3 (2)<br />

1½ in. ★<br />

5 (2) 2 in. ★<br />

7 3 in. ★<br />

Maximum Working Pressure<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 1000 PSI ★<br />

Isolating Diaphragm Material Upper Housing Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

LA00<br />

Exp<strong>and</strong>ed<br />

316L SST 316L SST ★<br />

LB00 Alloy C-276 316L SST<br />

Options (Include with selected model number)<br />

Remote <strong>Seal</strong> Diaphragm Polishing<br />

Exp<strong>and</strong>ed<br />

R6 Electropolishing<br />

Remote <strong>Seal</strong> Diaphragm Surface Finish<br />

Exp<strong>and</strong>ed<br />

RD 10 �in. (0.25 �m) Ra Diaphragm Surface Finish<br />

RG 15 �in. (0.375 �m) Ra Diaphragm Surface Finish<br />

RH 20 �in. (0.5 �m) Ra Diaphragm Surface Finish<br />

Surface Finish Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q16 Surface Finish Certification for Hygienic Remote <strong>Seal</strong>s ★<br />

Complete the 3051SAL model number by specifying options as needed:<br />

page 12 ERS Transmitter Options<br />

page 18 Scalable <strong>Level</strong> Transmitter Options<br />

(1) Clamp <strong>and</strong> gasket furnished by user. The maximum working pressure is dependent upon the clamp pressure rating.<br />

(2) Consult factory for calibrated spans lower than 5 psi (345 mbar).<br />

29


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

30<br />

Hygienic Tank Spud (SS) <strong>Seal</strong><br />

• Commonly used in hygienic level applications<br />

• <strong>Seal</strong> diaphragm installed flush with inner tank wall<br />

• Conforms to 3-A st<strong>and</strong>ard 74-03<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 9. SS Hygienic Tank Spud <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common models <strong>and</strong> options. These options should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Process Connection<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SS (1) Hygienic Tank Spud <strong>Seal</strong> ★<br />

Process Connection Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 4-in. Sch. 5 Tri-Clamp ★<br />

Maximum Working Pressure (Clamp Rating)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 600 PSI (41 bar) ★<br />

Upper Housing<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 316L SST ★<br />

Diaphragm <strong>and</strong> Wetted, Extension Material<br />

Diaphragm <strong>and</strong> Wetted Extension<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

AL 316L SST (2)<br />

316L SST (2)<br />

Exp<strong>and</strong>ed<br />

★<br />

BB Alloy C-276 316L SST<br />

Extension Length<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 2-in. (50 mm) Extension ★<br />

6 6-in. (150 mm) Extension ★<br />

Options (Include with selected model number)<br />

Remote <strong>Seal</strong> Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

SC 0.006-in. (150 �m) Diaphragm Thickness<br />

Tank Spud Included with Shipment<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

S1 Tank Spud Included with Shipment ★<br />

Remote <strong>Seal</strong> Diaphragm Polishing<br />

Exp<strong>and</strong>ed<br />

R6 Electropolishing<br />

Remote <strong>Seal</strong> Diaphragm Surface Finish<br />

Exp<strong>and</strong>ed<br />

RH<br />

RG<br />

20 �in. (0.5 �m) Ra Diaphragm Surface Finish<br />

(3)<br />

15 �in. (0.375 �m) Ra Diaphragm Surface Finish<br />

Additional Options<br />

Surface Finish Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q16 Surface Finishing Certification for Hygienic Remote <strong>Seal</strong>s ★<br />

Complete the 3051SAL model number by specifying options as needed:<br />

page 12 ERS Transmitter Options<br />

page 18 Scalable <strong>Level</strong> Transmitter Options


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(1) Clamp <strong>and</strong> Ethylene Propylene o-ring (conforms to 3-A st<strong>and</strong>ard 74 <strong>and</strong> USP class VI) supplied.<br />

(2) Diaphragm brazed <strong>and</strong> TIG-welded to extension.<br />

(3) Require Option code R6 (Electropolishing).<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

31


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

<strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> 3051L level transmitters combine the features <strong>and</strong> benefits of a<br />

3051 pressure transmitter with the durability <strong>and</strong> reliability of a direct mount<br />

seal all in a single model number.<br />

<strong>Level</strong> transmitters can also be ordered with an additional <strong>1199</strong> remote seal<br />

to form a Tuned-System Assembly that offers improved performance <strong>and</strong><br />

reduced costs compared to traditional symmetrical (balanced) assemblies.<br />

Product features <strong>and</strong> capabilities include:<br />

• Variety of process connections<br />

• Quantified performance for the entire transmitter / seal assembly (QZ<br />

option)<br />

• 4-20 mA HART, FOUNDATION fieldbus, Profibus-PA, <strong>and</strong> 1-5 Vdc HART<br />

low power protocols<br />

Additional Information<br />

Specifications: page 89<br />

Certifications: page 107<br />

Dimensional Drawings: page 114<br />

Table 10. <strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Transmitter Type<br />

3051L <strong>Level</strong> Transmitter<br />

Pressure Range<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 –250 to 250 inH2O (–0,6 to 0,6 bar) ★<br />

3 –1000 to 1000 inH2O (–2,5 to 2,5 bar) ★<br />

4 –300 to 300 psi (–20,7 to 20,7 bar) ★<br />

Transmitter Output<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 4–20 mA with Digital Signal Based on HART Protocol ★<br />

F FOUNDATION fieldbus Protocol ★<br />

W<br />

32<br />

(1) Exp<strong>and</strong>ed<br />

Profibus – PA Protocol ★<br />

M (2)<br />

Low-Power 1–5 Vdc with Digital Signal Based on HART Protocol (See Option Code C2 for 0.8–3.2 Vdc Output)<br />

Process Connection Size, Material, Extension Length (High Side)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Code Process Connection Size Material Extension Length ★<br />

G0 (3) 2-in./DN 50 / 50A 316L SST None, Flush Mount ★<br />

H0 (3) 2-in./DN 50 / 50A Alloy C-276 None, Flush Mount ★<br />

J0 2-in./DN 50 / 50A Tantalum None, Flush Mount ★<br />

A0 (3) 3-in./DN 80 / 80A 316L SST None, Flush Mount ★<br />

A2 (3) 3-in./DN 80 / 80A 316L SST 2-in./50 mm ★<br />

A4 (3) 3-in./DN 80 / 80A 316L SST 4-in./100 mm ★<br />

A6 (3) 3-in./DN 80 / 80A 316L SST 6-in./150 mm ★<br />

B0 (3) 4-in./DN 100 / 100A 316L SST None, Flush Mount ★<br />

B2 (3) 4-in./DN 100 / 100A 316L SST 2-in./50 mm ★<br />

B4 (3) 4-in./DN 100 / 100A 316L SST 4-in./100 mm ★<br />

B6 (3) 4-in./DN 100 / 100A 316L SST 6-in./150 mm ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

C0 (3) 3-in./DN 80 / 80A Alloy C-276 None, Flush Mount ★<br />

C2 (3) 3-in./DN 80 / 80A Alloy C-276 2-in./50 mm ★<br />

C4 (3) 3-in./DN 80 / 80A Alloy C-276 4-in./100 mm ★<br />

C6 (3) 3-in./DN 80 / 80A Alloy C-276 6-in./150 mm ★<br />

D0 (3) 4-in./DN 100 / 100A Alloy C-276 None, Flush Mount ★<br />

D2 (3) 4-in./DN 100 / 100A Alloy C-276 2-in./50 mm ★<br />

D4 (3) 4-in./DN 100 / 100A Alloy C-276 4-in./100 mm ★<br />

D6 (3) 4-in./DN 100 / 100A Alloy C-276 6-in./150 mm ★<br />

E0 3-in./DN 80 / 80A Tantalum None, Flush Mount ★<br />

F0 4-in./DN 100 / 100A Tantalum None, Flush Mount ★<br />

Mounting Flange Size, Rating, Material (High Side)<br />

Size Rating Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

M 2-in. ANSI/ASME B16.5 Class 150 CS ★<br />

A 3-in. ANSI/ASME B16.5 Class 150 CS ★<br />

B 4-in. ANSI/ASME B16.5 Class 150 CS ★<br />

N 2-in. ANSI/ASME B16.5 Class 300 CS ★<br />

C 3-in. ANSI/ASME B16.5 Class 300 CS ★<br />

D 4-in. ANSI/ASME B16.5 Class 300 CS ★<br />

P 2-in. ANSI/ASME B16.5 Class 600 CS ★<br />

E 3-in. ANSI/ASME B16.5 Class 600 CS ★<br />

X (3) 2-in. ANSI/ASME B16.5 Class 150 316 SST ★<br />

F (3) 3-in. ANSI/ASME B16.5 Class 150 316 SST ★<br />

G (3) 4-in. ANSI/ASME B16.5 Class 150 316 SST ★<br />

Y (3) 2-in. ANSI/ASME B16.5 Class 300 316 SST ★<br />

H (3) 3-in. ANSI/ASME B16.5 Class 300 316 SST ★<br />

J (3) 4-in. ANSI/ASME B16.5 Class 300 316 SST ★<br />

Z (3) 2-in. ANSI/ASME B16.5 Class 600 316 SST ★<br />

L (3) 3-in. ANSI/ASME B16.5 Class 600 316 SST ★<br />

Q DN 50 PN 40 per EN 1092-1 CS ★<br />

R DN 80 PN 40 per EN 1092-1 CS ★<br />

S DN 100 PN 40 per EN 1092-1 CS ★<br />

V DN 100 PN 10 / 16 per EN 1092-1 CS ★<br />

K (3) DN 50 PN 40 per EN 1092-1 316 SST ★<br />

T (3) DN 80 PN 40 per EN 1092-1 316 SST ★<br />

U (3) DN 100 PN 40 per EN 1092-1 316 SST ★<br />

W (3) DN 100 PN 10 / 16 per EN 1092-1 316 SST ★<br />

7 (3) Exp<strong>and</strong>ed<br />

4 in. ANSI/ASME B16.5 Class 600 316 SST ★<br />

1 — 10K per JIS B2238 CS<br />

2 — 20K per JIS B2238 CS<br />

3 — 40K per JIS B2238 CS<br />

4 (3) — 10K per JIS B2238 316 SST<br />

5 (3) — 20K per JIS B2238 316 SST<br />

6 (3) — 40K per JIS B2238 316 SST<br />

<strong>Seal</strong> Fill Fluid Specific Gravity at 77 °F (25 °C) Temperature Limits (4)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Syltherm XLT 0.85 -102 to 293 °F (-75 to 145 °C) ★<br />

C (5) Table 10. <strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Silicone 704 1.07 32 to 401 °F (0 to 205 °C) ★<br />

D Silicone 200 0.93 -49 to 401 °F (-45 to 205 °C) ★<br />

H Inert (Halocarbon) 1.85 -49 to 320 °F (-45 to 160 °C) ★<br />

33


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

34<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

G (6)(7) Glycerine <strong>and</strong> Water 1.13 5 to 203 °F (-15 to 95 °C) ★<br />

N (5)(6)<br />

Neobee M-20 0.92 5 to 401 °F (-15 to 205 °C) ★<br />

P (6)(7) Table 10. <strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Propylene Glycol <strong>and</strong><br />

Water<br />

1.02 5 to 203 °F (-15 to 95 °C) ★<br />

Low Pressure Side<br />

Configuration Diaphragm Material Sensor Fill Fluid<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

11 (3) Gage 316L SST Silicone ★<br />

21 Differential 316L SST Silicone ★<br />

22 Differential Alloy C-276 Silicone ★<br />

2A Differential 316L SST Inert (Halocarbon) ★<br />

2B Differential Alloy C-276 Inert (Halocarbon) ★<br />

31 (3) Tuned-System Assembly<br />

with Remote <strong>Seal</strong><br />

316L SST Silicone (Requires Option Code S1) ★<br />

O-ring<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Glass-filled PTFE ★<br />

Housing Material Conduit Entry Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Aluminum ½–14 NPT ★<br />

B Aluminum M20 × 1.5 ★<br />

J SST ½–14 NPT ★<br />

K SST M20 × 1.5 ★<br />

Exp<strong>and</strong>ed<br />

D Aluminum G½<br />

M SST G½<br />

Options (Include with selected model number)<br />

PlantWeb Control Functionality<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A01 FOUNDATION fieldbus Advanced Control Function Block Suite ★<br />

PlantWeb Diagnostic Functionality<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D01 FOUNDATION fieldbus Diagnostics Suite ★<br />

<strong>Seal</strong> Assemblies<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

S1 (8) Assembled to One <strong>Rosemount</strong> <strong>1199</strong> <strong>Seal</strong> (Requires <strong>1199</strong>M) ★<br />

Product Certifications<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

E5 FM Explosion-proof, Dust Ignition-proof ★<br />

I5 FM Intrinsically Safe, Division 2 ★<br />

K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, <strong>and</strong> Division 2 ★<br />

I1 (9)<br />

ATEX Intrinsic Safety <strong>and</strong> Dust ★<br />

N1 (9)<br />

ATEX Type n Certification <strong>and</strong> Dust ★<br />

E8 ATEX Flameproof <strong>and</strong> Dust Certification ★<br />

E4 (9) TIIS Flameproof ★<br />

E3 China Flameproof ★<br />

I3 China Intrinsic Safety, Dust Ignition-proof ★<br />

C6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, <strong>and</strong> Division 2 ★<br />

K6 (9)<br />

CSA <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe, <strong>and</strong> Division 2 (combination of C6 <strong>and</strong> K8) ★<br />

KB FM <strong>and</strong> CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, <strong>and</strong> Division 2 (combination of K5 <strong>and</strong> C6) ★<br />

K7 IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, <strong>and</strong> Type n (combination of I7, N7, <strong>and</strong> E7) ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

K8 (9) ATEX Flame-proof <strong>and</strong> Intrinsic Safety Approvals (combination of I1 <strong>and</strong> E8) ★<br />

KD (9) Table 10. <strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

FM, CSA, <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, <strong>and</strong> E8) ★<br />

I7 IECEx Intrinsic Safety ★<br />

E7 IECEx Flameproof, Dust Ignition-proof ★<br />

N7 IECEx Type n Certification ★<br />

IA ATEX FISCO Intrinsic Safety ★<br />

IE FM FISCO Intrinsically Safe ★<br />

E2 INMETRO Flameproof ★<br />

I2 INMETRO Intrinsic Safety ★<br />

K2 INMETRO Flameproof, Intrinsic Safety ★<br />

Shipboard Approvals<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SBS American Bureau of Shipping (ABS) Type Approval ★<br />

SBV Bureau Veritas (BV) Type Approval ★<br />

SDN Det Norske Veritas (DNV) Type Approval ★<br />

SLL Lloyds Register (LR) Type Approval ★<br />

Bolting Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

L4 Austenitic 316 SST Bolts ★<br />

L5 ASTM A 193, Grade B7M bolts ★<br />

L6 Alloy K-500 Bolts ★<br />

L8 ASTM A 193 Class 2, Grade B8M Bolts ★<br />

Display Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

M4 (10)<br />

LCD Display with Local Operator Interface ★<br />

M5 LCD Display for Aluminum Housing (Housing Codes A, B, C, <strong>and</strong> D only) ★<br />

M6 LCD Display for SST Housing (Housing Codes J, K, L, <strong>and</strong> M only) ★<br />

Calibration Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q4 Calibration Certificate ★<br />

QP Calibration Certificate <strong>and</strong> tamper evident seal ★<br />

QG Calibration Certificate <strong>and</strong> GOST Verification Certificate ★<br />

Material Traceability Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q8 Material Traceability Certification per EN 10204 3.1 ★<br />

Quality Certification for Safety<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QS (11)<br />

Prior-use certificate of FMEDA data ★<br />

Conduit Electrical Connector<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

GE M12, 4-pin, Male Connector (eurofast ® ) ★<br />

GM A size Mini, 4-pin, Male Connector (minifast ® ) ★<br />

Configuration Buttons<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

J1 (12)(13)<br />

J3 (12)(13)<br />

Transient Protection<br />

Local Zero Adjustment Only ★<br />

No Local Zero or Span Adjustment ★<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T1 (14)<br />

Transient Protection Terminal Block ★<br />

35


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 10. <strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Software Configuration<br />

36<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C1 (12) Custom Software Configuration (Completed CDS 00806-0100-4001 required with order) ★<br />

Low Power Output<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C2 (12) 0.8–3.2 Vdc Output with Digital Signal Based on HART Protocol (Available with Output code M only) ★<br />

Alarm Limit<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C4 (12)(15)<br />

NAMUR alarm <strong>and</strong> saturation levels, high alarm ★<br />

CN (12)(15) NAMUR alarm <strong>and</strong> saturation levels, low alarm ★<br />

CR Custom alarm <strong>and</strong> saturation signal levels, high alarm ★<br />

CS Custom alarm <strong>and</strong> saturation signal levels, low alarm ★<br />

CT Low alarm (st<strong>and</strong>ard <strong>Rosemount</strong> alarm <strong>and</strong> saturation levels) ★<br />

Conduit Plug<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D0 316 SST Conduit Plug ★<br />

Ground Screw<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

V5 (16) External Ground Screw Assembly ★<br />

Lower Housing Flushing Connection Options<br />

Ring Material Number Size (NPT)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

F1 316 SST 1<br />

1<br />

/4-18 NPT ★<br />

F2 316 SST 2 1 /4-18 NPT ★<br />

F3 Alloy C-276 1 1 /4-18 NPT ★<br />

F4 Alloy C-276 2<br />

1<br />

/4-18 NPT ★<br />

F7 316 SST 1 1 /2-14 NPT ★<br />

F8 316 SST 2 1 /2-14 NPT ★<br />

F9 Alloy C-276 1<br />

1<br />

/2-14 NPT ★<br />

F0 Alloy C-276 2 1 /2-14 NPT ★<br />

Flange Adapters<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

DF (17) 1/2-14 NPT flange adapter ★<br />

RC1/4 RC1/2 Process Connection<br />

Exp<strong>and</strong>ed<br />

D9 (17) JIS Process Connection - RC 1/2 Flange Adapter<br />

Toolkit Total System Performance Reports<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QZ Remote <strong>Seal</strong> System Performance Calculation Report ★<br />

Typical Model Number: 3051L 2 A A0 A D 21 A A F1<br />

(1) Option Code M4 - LCD Display with Local Operator Interface required for local addressing <strong>and</strong> configuration.<br />

(2) Not available with hazardous certification Option Codes I1, N1, E4, K6, <strong>and</strong> K8.<br />

(3) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(4) At ambient pressure of 14.7 psia (1 bar-a) <strong>and</strong> ambient temperature of 70°F (21°C). Temperature limits are reduced in vacuum service <strong>and</strong> may be limited<br />

by seal selection.<br />

(5) Maximum process temperature is limited by heat transfer to the transmitter <strong>and</strong> must be further derated if ambient, temperature exceeds 70 °F (21 °C).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(6) This is a food grade fill fluid.<br />

(7) Not suitable for vacuum applications.<br />

(8) “Assemble-to” items are specified separately <strong>and</strong> require a completed model number.<br />

(9) Not available with low-power Option Code M<br />

(10) Available only with output code W - Profibus PA<br />

(11) Only available with HART 4-20 mA output (output code A).<br />

(12) Not available with fieldbus (output code F) or profibus protocols (output code W).<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

(13) Local zero <strong>and</strong> span adjustments are st<strong>and</strong>ard unless Option Code J1 or J3 is specified.<br />

(14) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, <strong>and</strong> IG.<br />

(15) NAMUR-Compliant operation is pre-set at the factory <strong>and</strong> cannot be changed to st<strong>and</strong>ard operation in the field.<br />

(16) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.<br />

(17) Not available with Remote Mount <strong>Seal</strong> Assembly option S1.<br />

37


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Tuned-System Assembly Comprised of<br />

2051L with <strong>1199</strong> Remote Mount <strong>Seal</strong><br />

<strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> 2051L level transmitters combine the features <strong>and</strong> benefits of a<br />

2051 pressure transmitter with the durability <strong>and</strong> reliability of a direct mount<br />

seal all in a single model number.<br />

<strong>Level</strong> transmitters can also be ordered with an additional <strong>1199</strong> remote seal<br />

to form a Tuned-System Assembly that offers improved performance <strong>and</strong><br />

reduced costs compared to traditional symmetrical (balanced) assemblies.<br />

Product features <strong>and</strong> capabilities include:<br />

• Variety of process connections<br />

• Quantified performance for the entire transmitter / seal assembly (QZ<br />

option)<br />

• 4-20 mA HART, FOUNDATION fieldbus, <strong>and</strong> 1-5 Vdc HART Low-Power<br />

outputs<br />

Additional Information<br />

Specifications: page 89<br />

Certifications: page 111<br />

Dimensional Drawings: page 114<br />

Table 11. <strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Transmitter Type<br />

2051L <strong>Level</strong> Transmitter<br />

Pressure Range<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 –250 to 250 inH 2O (–0,6 to 0,6 bar) ★<br />

3 –1000 to 1000 inH 2O (–2,5 to 2,5 bar) ★<br />

4 –300 to 300 psi (–20,7 to 20,7 bar) ★<br />

Transmitter Output<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 4–20 mA with Digital Signal Based on HART Protocol ★<br />

F FOUNDATION fieldbus Protocol ★<br />

W (1) Profibus - PA Protocol ★<br />

Exp<strong>and</strong>ed<br />

M Low-Power, 1–5 Vdc with Digital Signal Based on HART Protocol<br />

Process Connection Size, Diaphragm Material (High Side)<br />

Process Connection Size Diaphragm<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

G<br />

38<br />

(2) 2 in./DN 50 316L SST ★<br />

H (2)<br />

2 in./DN 50 Alloy C-276 ★<br />

J 2 in./DN 50 Tantalum ★<br />

A (2) 3 in./DN 80 316L SST ★<br />

B (2)<br />

4 in./DN 100 316L SST ★<br />

C (2) 3 in./DN 80 Alloy C-276 ★<br />

D (2) 4 in./DN 100 Alloy C-276 ★<br />

E 3 in./DN 80 Tantalum ★<br />

F 4 in./DN 100 Tantalum ★<br />

Extension Length (High Side)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 None, Flush Mount ★<br />

2 2 in./50 mm ★<br />

4 4 in./100 mm ★<br />

6 6 in./150 mm ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 11. <strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Mounting Flange Size, Rating, Material (High Side)<br />

Size Rating Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

M 2-in. ANSI/ASME B16.5 Class 150 CS ★<br />

A 3-in. ANSI/ASME B16.5 Class 150 CS ★<br />

B 4-in. ANSI/ASME B16.5 Class 150 CS ★<br />

N 2-in. ANSI/ASME B16.5 Class 300 CS ★<br />

C 3-in. ANSI/ASME B16.5 Class 300 CS ★<br />

D 4-in. ANSI/ASME B16.5 Class 300 CS ★<br />

X (2)<br />

2-in. ANSI/ASME B16.5 Class 150 316 SST ★<br />

F (2) 3-in. ANSI/ASME B16.5 Class 150 316 SST ★<br />

G (2) 4-in. ANSI/ASME B16.5 Class 150 316 SST ★<br />

Y (2)<br />

2-in. ANSI/ASME B16.5 Class 300 316 SST ★<br />

H (2) 3-in. ANSI/ASME B16.5 Class 300 316 SST ★<br />

J (2) 4-in. ANSI/ASME B16.5 Class 300 316 SST ★<br />

Q DN50 PN 40 per EN 1092-1 CS ★<br />

R DN80 PN 40 per EN 1092-1 CS ★<br />

K (2) DN50 PN 40 per EN 1092-1 316 SST ★<br />

T (2) DN80 PN 40 per EN 1092-1 316 SST ★<br />

<strong>Seal</strong> Fill Fluid Specific Gravity at 77 °F (25 °C) Temperature Limits (3)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Syltherm XLT 0.85 -102 to 293 °F (-75 to 145 °C) ★<br />

C (4) Silicone 704 1.07 32 to 401 °F (0 to 205 °C) ★<br />

D Silicone 200 0.93 -49 to 401 °F (-45 to 205 °C) ★<br />

H Inert (Halocarbon) 1.85 -49 to 320 °F (-45 to 160 °C) ★<br />

G (5)(6) Glycerin <strong>and</strong> Water 1.13 5 to 203 °F (-15 to 95 °C) ★<br />

N (4) Neobee M-20 0.92 5 to 401 °F (-15 to 205 °C) ★<br />

P (5)(6)<br />

Propylene Glycol <strong>and</strong> Water 1.02 5 to 203 °F (-15 to 95 °C) ★<br />

Sensor Module Configuration, Flange Adapter (Low Side)<br />

Configuration<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 (2) Gage ★<br />

2 Differential ★<br />

3 (2)<br />

Tuned-System Assembly with Remote <strong>Seal</strong> ★<br />

Sensor Module Diaphragm Material, Sensor Fill Fluid (Low Side)<br />

Diaphragm Material Sensor Fill Fluid<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 (2) 316L SST Silicone ★<br />

2 (2) Alloy C-276 (SST Valve<br />

Seat)<br />

Silicone ★<br />

7 (2) Alloy C-276 (SST Valve<br />

Seat)<br />

Silicone ★<br />

A (2) 316L SST Inert (Halocarbon) ★<br />

B (2)<br />

Alloy C-276 (SST Valve<br />

Seat)<br />

Inert (Halocarbon) ★<br />

G (2)<br />

O-ring<br />

Alloy C-276 (SST Valve<br />

Seat)<br />

Inert (Halocarbon) ★<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Glass-filled PTFE ★<br />

39


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 11. <strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Housing Material, Conduit Entry Size<br />

40<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Housing Material Conduit Entry Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Aluminum ½–14 NPT ★<br />

B Aluminum M20 × 1.5 ★<br />

J SST ½–14 NPT ★<br />

K<br />

Exp<strong>and</strong>ed<br />

SST M20 × 1.5 ★<br />

D Aluminum G½<br />

M SST G½<br />

Options (Include with selected model number)<br />

PlantWeb Control Functionality<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A01 FOUNDATION fieldbus Advanced Control Function Block Suite ★<br />

<strong>Seal</strong> Assemblies<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

S1 (7) Assemble to One <strong>Rosemount</strong> <strong>1199</strong> <strong>Seal</strong> (Requires <strong>1199</strong>M) ★<br />

Product Certifications<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

E1 (8) ATEX Flameproof ★<br />

E2 (8)<br />

INMETRO Flameproof ★<br />

E3 (8) China Flameproof ★<br />

E4 TIIS Flameproof ★<br />

E5 FM Explosion-proof, Dust Ignition-proof ★<br />

E6 CSA Explosion-proof, Dust Ignition-proof, Division 2 ★<br />

E7 (8) IECEx Flameproof ★<br />

EW India (CCOE) Flameproof Approval ★<br />

I1 (8) ATEX Intrinsic Safety ★<br />

I2 (8) INMETRO Intrinsically Safe ★<br />

I3 (8)<br />

China Intrinsic Safety ★<br />

I5 FM Intrinsically Safe, Division 2 ★<br />

I6 CSA Intrinsically Safe ★<br />

I7 (8)<br />

IECEx Intrinsic Safety ★<br />

IA (9) ATEX FISCO Intrinsic Safety ★<br />

IE (9) FM FISCO Intrinsically Safe ★<br />

IF (9)<br />

CSA FISCO Intrinsically Safe ★<br />

IG (9) IECEx FISCO Intrinsically Safe ★<br />

IW India (CCOE) Intrinsic Safety Approval ★<br />

K1 (8)<br />

ATEX Flameproof, Intrinsic Safety, Type n, Dust ★<br />

K2 INMETRO Flameproof, Intrinsic Safety, Type n ★<br />

K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

K6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

K7 (8) IECEx Flameproof, Intrinsic Safety, Type n ★<br />

KA (8) ATEX <strong>and</strong> CSA Flameproof, Intrinsically Safe, Division 2 ★<br />

KB FM <strong>and</strong> CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

KC (8) FM <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe, Division 2 ★<br />

KD (8) FM, CSA, <strong>and</strong> ATEX Explosion-proof, Intrinsically Safe ★<br />

N1 (8)<br />

ATEX Type n ★<br />

N7 (8) IECEx Type n ★<br />

ND (8) ATEX Dust ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Shipboard Approvals<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SBS American Bureau of Shipping (ABS) Type Approval ★<br />

SBV Bureau Veritas (BV) Type Approval ★<br />

SDN Det Norske Veritas (DNV) Type Approval ★<br />

SLL Lloyds Register (LR) Type Approval ★<br />

Digital Display<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

M4 (10)<br />

LCD Display With Local Operator Interface ★<br />

M5 LCD display ★<br />

Hardware Adjustments<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D4 (11) Zero <strong>and</strong> Span Hardware Adjustments ★<br />

Flange Adapters<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

DF (12) 1 /2-14 NPT Flange Adapters ★<br />

Conduit Plug<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

DO (13) 316 SST Conduit Plug ★<br />

RC1/4 RC1/2 Process Connection<br />

Exp<strong>and</strong>ed<br />

D9 (11) JIS Process Connection - RC 1/2 Flange Adapter<br />

Ground Screw<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

V5 (14) External Ground Screw Assembly ★<br />

Transient Protection<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T1 (15) Transient Terminal Block ★<br />

Software Configuration<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C1 (16) Custom Software Configuration (Requires completed Configuration Data Sheet) ★<br />

Alarm Limit<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

C4 (16)(17) NAMUR alarm <strong>and</strong> saturation levels, high alarm ★<br />

CN (16)(18) NAMUR alarm <strong>and</strong> saturation levels, low alarm ★<br />

Calibration Certification<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q4 Calibration Certificate1 ★<br />

Alarm Limit<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

Q8 Material Traceability Certification per EN 10204 3.1 ★<br />

Quality Certification for Safety<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QS (16)<br />

Prior-use certificate of FMEDA data ★<br />

Toolkit Total System Performance Reports<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

QZ Remote <strong>Seal</strong> System Performance Calculation Report ★<br />

Lower Housing Flushing Connection Ring Material Number Size (NPT)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

F1 316 SST 1<br />

1<br />

/4-18 NPT ★<br />

F2 316 SST 2 1 /4-18 NPT ★<br />

F3 (18) Alloy C-276 1 1 /4-18 NPT ★<br />

F4 (18)<br />

Table 11. <strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Alloy C-276 2<br />

1<br />

/4-18 NPT ★<br />

41


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

42<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 11. <strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

F7 316 SST 1 1 /2-14 NPT ★<br />

F8 316 SST 2 1 /2-14 NPT ★<br />

F9 Alloy C-276 1<br />

1<br />

/2-14 NPT ★<br />

F0 Alloy C-276 2 1 /2-14 NPT ★<br />

Typical Model Number: 2051L 2 A A0 X D 21 A A B4 M5 F1<br />

(1) Option Code M4 - LCD Display with Local Operator Interface required for local addressing <strong>and</strong> configuration.<br />

(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(3) At ambient pressure of 14.7 psia (1 bar-a) <strong>and</strong> ambient temperature of 70°F (21°C). Temperature limits are reduced in vacuum service <strong>and</strong> may be limited by<br />

seal selection.<br />

(4) Maximum process temperature is limited by heat transfer to the transmitter electronics <strong>and</strong> must be further derated if ambient temperatures exceed 70°F (21°C).<br />

(5) This is a food grade fill fluid.<br />

(6) Not suitable for vacuum applications.<br />

(7) “Assemble-to” items are specified separately <strong>and</strong> require a completed model number.<br />

(8) Not available with Low Power output code M.<br />

(9) Only valid with FOUNDATION fieldbus output code F.<br />

(10) Available only with output code W-PROFIBUS PA.<br />

(11) Not valid with FOUNDATION fieldbus output code F.<br />

(12) Not available with Remote Mount <strong>Seal</strong> Assembly option S1.<br />

(13) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of st<strong>and</strong>ard carbon steel conduit plug,<br />

(14) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.<br />

(15) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, <strong>and</strong> IG.<br />

(16) Only available with HART 4-20 mA output (output code A).<br />

(17) NAMUR-Compliant operation is pre-set at the factory <strong>and</strong> cannot be changed to st<strong>and</strong>ard operation in the field.<br />

(18) Not available with Option Codes A0, B0, <strong>and</strong> G0.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

<strong>Rosemount</strong> <strong>1199</strong> Direct Mount <strong>Seal</strong> <strong>Systems</strong><br />

Tuned-System Assembly Comprised of<br />

<strong>1199</strong> Direct Mount <strong>Seal</strong> combined with<br />

<strong>1199</strong> Remote Mount <strong>Seal</strong><br />

<strong>Rosemount</strong> <strong>1199</strong> Direct Mount <strong>Seal</strong>s reduce installation costs by eliminating<br />

mounting hardware. Their advanced design also minimizes oil volume<br />

improving performance.<br />

Product features <strong>and</strong> capabilities include:<br />

• Direct Mount gage or absolute seal system can be used for open or<br />

vented to atmosphere tank applications<br />

• Tuned-System Assembly order codes can be used to improve<br />

performance for <strong>DP</strong> measurements in closed or pressurized tank<br />

applications<br />

• Variety of process connections<br />

• Quantified performance for the entire transmitter / seal assembly<br />

(QZ option)<br />

Additional Information<br />

Specifications: page 99<br />

Dimensional Drawings: page 114<br />

<strong>Rosemount</strong> <strong>1199</strong> Direct Mount <strong>Seal</strong><br />

The <strong>1199</strong> Direct Mount <strong>Seal</strong> also requires specification of a <strong>Rosemount</strong> pressure transmitter. See the appropriate<br />

Product Data Sheet for the desired transmitter <strong>and</strong> include the option indicated in the table below for the<br />

configuration desired.<br />

Table 12. When ordering <strong>Rosemount</strong> <strong>1199</strong> Direct <strong>and</strong> Remote Mount <strong>Seal</strong>s, please make sure to add the correct seal system<br />

ordering code to the transmitter model<br />

Transmitter Model 2 <strong>Seal</strong>s 1 <strong>Seal</strong><br />

3051S_C B12 B11<br />

3051C - Welded-Repairable S2 S1<br />

3051C - All Welded (1)<br />

S9 S0<br />

2051C S2 S1<br />

3051S_T — B11<br />

3051T, 2051T, 2088 — S1<br />

(1) All welded system connection types require either a 316L SST or Alloy C-276 isolating diaphragm in the pressure transmitter model codes.<br />

A <strong>1199</strong> Direct Mount <strong>Seal</strong> consists of 2 parts. First, specify the direct mount connection model codes found on page<br />

44. Then, specify a remote seal found on page 45.<br />

Ordering Codes<br />

<strong>1199</strong> _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _<br />

Direct Mount Connection page 44 <strong>Seal</strong> Connection page 45<br />

43


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 13. <strong>Rosemount</strong> <strong>1199</strong> Direct Mount <strong>Seal</strong> <strong>Systems</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

44<br />

Model Product Description<br />

<strong>1199</strong> <strong>Seal</strong> <strong>Systems</strong><br />

Connection Type <strong>Seal</strong> System <strong>Seal</strong> Location<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

3051S <strong>and</strong> 2051C Coplanar <strong>Transmitters</strong> (3051S_C <strong>and</strong> 2051C)<br />

W Welded-Repairable One or Two <strong>Seal</strong> System High Side of Transmitter ★<br />

R (1)<br />

All Welded One <strong>Seal</strong> System High Side of Transmitter ★<br />

T (1)<br />

All Welded Two <strong>Seal</strong> System High Side of Transmitter ★<br />

All In-Line <strong>Transmitters</strong> (3051S_T, 3051T, 2051T, 2088)<br />

W All Welded One <strong>Seal</strong> System — ★<br />

3051C Coplanar <strong>Transmitters</strong> (3051C)<br />

W Determined by Transmitter<br />

Code<br />

<strong>Seal</strong> Fill Fluid Specific<br />

Gravity at 77<br />

°F (25 °C)<br />

One or Two <strong>Seal</strong> System High Side of Transmitter ★<br />

No Extension 2-in. (50 mm)<br />

Extension<br />

Temperature Limits (2)<br />

4-in. (100 mm)<br />

Extension<br />

Thermal<br />

Optimizer<br />

St<strong>and</strong>ard<br />

St<strong>and</strong>ard ★<br />

A Syltherm XLT 0.85 -102 to 293 °F -102 to 293 °F 102 to 293 °F 102 to 293 °F<br />

★<br />

(-75 to 145 °C) (-75 to 145 °C) (-75 to 145 °C) (-75 to 145 °C)<br />

C (3) Silicone 704 1.07 32 to 401 °F<br />

(0 to 205 °C) (4)<br />

32 to 464 °F<br />

(0 to 240 °C) (4)<br />

32 to 500 °F<br />

(0 to 260 °C) (4)<br />

32 to 599 °F<br />

★<br />

(0 to 315 °C)<br />

D Silicone 200 0.93 -49 to 401 °F<br />

(-45 to 205 °C) (4)<br />

-49 to 401 °F -49 to 401 °F -49 to 401 °F<br />

★<br />

(-45 to 205 °C) (-45 to 205 °C) (-45 to 205 °C)<br />

H Inert<br />

1.85 -49 to 320 °F -49 to 320 °F -49 to 320 °F -49 to 320 °F<br />

★<br />

(Halocarbon)<br />

(-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C)<br />

G (5)(6) Glycerine 1.13 5 to 203 °F 5 to 203 °F 5 to 203 °F 5 to 203 °F<br />

★<br />

<strong>and</strong> Water<br />

(-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C)<br />

N (5) Neobee M-20 0.92 5 to 401 °F (4) 5 to 437 °F 5 to 437 °F 5 to 437 °F<br />

★<br />

(-15 to 205 °C) (-15 to 225 °C) (-15 to 225 °C) (-15 to 225 °C)<br />

P (5)(6)<br />

Propylene 1.02 5 to 203 °F 5 to 203 °F 5 to 203 °F 5 to 203 °F<br />

★<br />

Glycol <strong>and</strong><br />

Water<br />

(-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C) (-15 to 95 °C)<br />

<strong>Seal</strong> Connection Type<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A Direct Mount ★<br />

Direct Mount Connection Type<br />

Extension Length <strong>Seal</strong> System Connection Type<br />

St<strong>and</strong>ard<br />

All Coplanar <strong>Transmitters</strong> (3051S_C, 3051C <strong>and</strong> 2051C)<br />

St<strong>and</strong>ard<br />

94 Direct Mount, No Extension Tuned-System Assembly, two seals Welded-Repairable ★<br />

93 Direct Mount, No Extension One <strong>Seal</strong> System Welded-Repairable ★<br />

96 Direct Mount, No Extension Tuned-System Assembly, two seals All Welded ★<br />

97 Direct Mount, No Extension One <strong>Seal</strong> System All Welded ★<br />

B4 Direct Mount, 2 in. (50 mm) Extension Tuned-System Assembly, two seals Welded-Repairable ★<br />

B3 Direct Mount, 2 in. (50 mm) Extension One <strong>Seal</strong> System Welded-Repairable ★<br />

B6 Direct Mount, 2 in. (50 mm) Extension Tuned-System Assembly, two seals All Welded ★<br />

B7 Direct Mount, 2 in. (50 mm) Extension One <strong>Seal</strong> System All Welded ★<br />

D4 Direct Mount, 4 in. (100 mm) Extension Tuned-System Assembly, two seals Welded-Repairable ★<br />

D3 Direct Mount, 4 in. (100 mm) Extension One <strong>Seal</strong> System Welded-Repairable ★<br />

D6 Direct Mount, 4 in. (100 mm) Extension Tuned-System Assembly, two seals All Welded ★<br />

D7 Direct Mount, 4 in. (100 mm) Extension One <strong>Seal</strong> System All Welded ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 13. <strong>Rosemount</strong> <strong>1199</strong> Direct Mount <strong>Seal</strong> <strong>Systems</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

All In-Line <strong>Transmitters</strong> (3051S_T, 3051T, 2051T, 2088)<br />

95 Direct Mount, No Extension One <strong>Seal</strong> System All Welded ★<br />

D5 Thermal Optimizer One <strong>Seal</strong> System All Welded ★<br />

(1) All welded system connection types require either a 316L SST or Alloy C-276 isolating diaphragm in the pressure transmitter model codes.<br />

(2) At ambient pressure of 14.7 psia (1 bar-a) <strong>and</strong> ambient temperature of 70°F (21 °C).<br />

(3) Not available with <strong>Seal</strong> Connection Type \ Capillary ID, Description codes B, E, H or M.<br />

(4) Maximum process temperature is limited by heat transfer to the transmitter <strong>and</strong> must be further derated if ambient temperature exceeds 70 °F.<br />

(5) This is a food grade fill fluid.<br />

(6) Not suitable for vacuum applications.<br />

Continue specifying a completed model number by choosing a remote seal type below:<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Flanged <strong>Seal</strong> Assemblies<br />

● = Transmitter Availability<br />

— = Unavailable<br />

Coplanar<br />

Extensions<br />

Inline 0 in. 2-in. 4-in. Process Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

page 54 FFW Flush Flanged <strong>Seal</strong> ● (1) ● ● 2-in. / DN 50 / 50A<br />

3-in. / DN 80 / 80A<br />

4-in. / DN 100 / 100A<br />

★<br />

Exp<strong>and</strong>ed<br />

page 57 RFW Flanged <strong>Seal</strong> ● — ● ● 1 /2-in. / DN 15<br />

3 /4-in.<br />

1-in. / DN 25 / 25A<br />

1 1 /2-in. / DN 40 / 40A<br />

page 60 EFW Extended Flanged <strong>Seal</strong> ● (1) ● ● 1 1 /2-in. / DN 40 / 40A<br />

2-in. / DN 50 / 50A<br />

3-in. / Headbox<br />

/ DN 80 / 80A<br />

4-in. / Headbox<br />

/ DN 100 / 100A<br />

page 65 FCW Flush Flanged <strong>Seal</strong> – Ring Type Joint<br />

(RTJ) Gasket Surface<br />

● (1) ● ● 2-in.<br />

3-in.<br />

page 67 RCW Ring Type Joint (RTJ) Flanged <strong>Seal</strong> ● — ● ● ½-in.<br />

¾-in.<br />

1-in.<br />

1 ½-in.<br />

page 69 FUW <strong>and</strong> FVW Flush Flanged Type <strong>Seal</strong>s ● ● ● ● DN 50<br />

DN 80<br />

★<br />

★<br />

45


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

46<br />

Threaded <strong>Seal</strong> Assemblies<br />

Coplanar<br />

Extensions<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Inline 0 in. 2-in. 4-in. Process Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

page 70 RTW Threaded <strong>Seal</strong> ● — ● ● ¼ –18 NPT<br />

3<br />

/8 –18 NPT<br />

½ –14 NPT<br />

¾ –14 NPT<br />

1 – 11.5 NPT<br />

1 ¼ –11.5 NPT<br />

1 ½ –11.5 NPT<br />

G 1 /2 A DIN 16288<br />

R1 /2 per ISO 7/1<br />

★<br />

Exp<strong>and</strong>ed<br />

page 73 HTS Male Threaded <strong>Seal</strong> ● ● ● ● G1<br />

G1 ½<br />

G2<br />

1-11.5 NPT<br />

1 ½ -11.5 NPT<br />

2-11.5 NPT<br />

Hygienic <strong>Seal</strong> Assemblies<br />

Coplanar<br />

Extensions<br />

Inline 0 in. 2-in. 4-in. Process Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

page 74 SCW Hygienic Tri-Clover Style Tri-Clamp ● ● ● ● 1 ½-in.<br />

★<br />

<strong>Seal</strong><br />

2-in.<br />

2 ½-in.<br />

3-in.<br />

4-in.<br />

Exp<strong>and</strong>ed<br />

page 76 SSW Hygienic Tank Spud <strong>Seal</strong> ● ● ● ● 2-in. Extension<br />

6-in. Extension<br />

page 78 STW Hygienic Thin Wall Tank Spud <strong>Seal</strong> ● — ● ● 0.8 in Extension<br />

page 79 EES Hygienic Flanged Tank Spud<br />

Extended <strong>Seal</strong><br />

● ● ● ● DN 50<br />

DN 80<br />

page 80 VCS Tri-clamp ® In-Line <strong>Seal</strong> ● — — — 1-in.<br />

1 ½-in.<br />

2-in.<br />

3-in.<br />

4-in.<br />


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

page 81 SVS Varivent ® Compatible Hygienic<br />

● ● ● ● Tuchenhagen Varivent<br />

Connection <strong>Seal</strong><br />

®<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Compatible<br />

Specialty <strong>Seal</strong> Assemblies<br />

Exp<strong>and</strong>ed<br />

page 82 SHP Hygienic Cherry-Burrell “I” Line <strong>Seal</strong> ● — — — 2-in.<br />

3-in.<br />

page 83 SLS Dairy Process Connection - Female<br />

Thread <strong>Seal</strong> per DIN 11851<br />

● — — — DN 40<br />

DN 50<br />

Inline<br />

Coplanar<br />

Extensions<br />

0 in. 2-in. 4-in.<br />

Process Connections<br />

page 84 WSP Saddle <strong>Seal</strong> ● — ● ● 2-in.<br />

3-in.<br />

4-in. or Larger<br />

page 85 UCP Male Threaded Pipe Mount <strong>Seal</strong>s <strong>and</strong><br />

PMW Paper Mill Sleeve <strong>Seal</strong>s<br />

● — — — 1 ½-in. with Threaded<br />

Knurled Nut<br />

1-in. with Cap Screw<br />

Retainer<br />

page 86 CTW Chemical Tee <strong>Seal</strong> ● — ● ● Retro-fit<br />

page 87 TFS Wafer Style In-Line <strong>Seal</strong> ● — — — 1-in. / DN 25<br />

1 ½-in. / DN 40<br />

2-in. / DN 50<br />

3-in. / DN 80<br />

4-in. / DN 100<br />

page 88 WFW Flow-Thru Flanged <strong>Seal</strong> ● — ● ● 1-in.<br />

2-in.<br />

3-in.<br />

(1) Available with ANSI Class 300 or EN 1092-1 PN 40 or JIS B2238 20K or lower flange ratings.<br />

47


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

48<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>1199</strong> Remote Mount <strong>Seal</strong> <strong>Systems</strong><br />

Tuned-System Assembly Comprised<br />

of <strong>1199</strong> Direct Mount <strong>Seal</strong> combined<br />

with <strong>1199</strong> Remote Mount <strong>Seal</strong><br />

<strong>Rosemount</strong> <strong>1199</strong> Remote Mount <strong>Seal</strong>s are used commonly at the top of the<br />

vessel when a <strong>DP</strong> measurement is required. The capillary that is used is<br />

available in three different diameters to optimize time response <strong>and</strong> reduce<br />

temperature effects.<br />

Product features <strong>and</strong> capabilities include:<br />

• Remote Mount <strong>Seal</strong>s can be used for high temperature applications<br />

• Remote Mount <strong>Seal</strong>s are used on the low pressure side of the transmitter<br />

for Tuned-System Assemblies that can be used for <strong>DP</strong> measurements in<br />

closed or pressurized tank applications<br />

• Variety of process connections<br />

• Quantified performance for the entire transmitter / seal assembly (QZ<br />

option)<br />

Additional Information<br />

Specifications: page 89<br />

Certifications: page 100<br />

Dimensional Drawings: page 114<br />

<strong>Rosemount</strong> <strong>1199</strong> Remote Mount <strong>Seal</strong><br />

The <strong>1199</strong> Remote Mount <strong>Seal</strong> also requires specification of a <strong>Rosemount</strong> pressure transmitter. See the appropriate<br />

Product Data Sheet for the desired transmitter <strong>and</strong> include the option indicated in the table below for the<br />

configuration desired.<br />

Table 14. When ordering <strong>Rosemount</strong> <strong>1199</strong> Direct <strong>and</strong> Remote Mount <strong>Seal</strong>s, please make sure to add the correct seal system<br />

ordering code to the transmitter model<br />

Transmitter Model 2 <strong>Seal</strong>s 1 <strong>Seal</strong><br />

3051S_C B12 B11<br />

3051C - Welded-Repairable S2 S1<br />

3051C - All Welded (1)<br />

S8 or S9 S7<br />

2051C S2 S1<br />

3051S_T — B11<br />

3051T, 2051T, 2088 — S1<br />

(1) All welded system connection types require either a 316L SST or Alloy C-276 isolating diaphragm in the pressure transmitter model codes.<br />

A <strong>1199</strong> Remote Mount <strong>Seal</strong> consists of 2 parts. First, specify the capillary model codes found on page 49. Then,<br />

specify a remote seal found on page 51.<br />

Ordering Codes<br />

<strong>1199</strong> _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _<br />

Remote Mount Connection page 49 <strong>Seal</strong> Connection page 51


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Capillary/Fill Fluid<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

NOTE:<br />

Use Table 15 for Capillary Type Connections. Use Table 13 for Direct Mount Type Connections.<br />

Table 15. <strong>Rosemount</strong> <strong>1199</strong> Remote Mount <strong>Seal</strong> <strong>Systems</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Model Product Description<br />

<strong>1199</strong> <strong>Seal</strong> System<br />

Connection Type <strong>Seal</strong> System <strong>Seal</strong> Location<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

3051S <strong>and</strong> 2051 Coplanar <strong>Transmitters</strong> (3051S_C <strong>and</strong> 2051C)<br />

W Welded-Repairable One or Two <strong>Seal</strong> System High Side of Transmitter ★<br />

M Welded-Repairable One or Two <strong>Seal</strong> System Low Side of Transmitter ★<br />

D Welded-Repairable Two <strong>Seal</strong> System Balanced System - Same <strong>Seal</strong> on Low <strong>and</strong> High Side ★<br />

R (1)<br />

All Welded One <strong>Seal</strong> System High Side of Transmitter ★<br />

T (1)<br />

All Welded Two <strong>Seal</strong> System High Side of Transmitter ★<br />

S (1) All Welded Two <strong>Seal</strong> System Low Side of Transmitter ★<br />

All In-Line <strong>Transmitters</strong> (3051S_T, 3051T, 2051T, 2088)<br />

W All Welded One <strong>Seal</strong> System — ★<br />

3051 Coplanar <strong>Transmitters</strong> (3051C)<br />

W Determined by Transmitter Code One or Two <strong>Seal</strong> System High Side of Transmitter ★<br />

M Determined by Transmitter Code One or Two <strong>Seal</strong> System Low Side of Transmitter ★<br />

D Determined by Transmitter Code Two <strong>Seal</strong> System Balanced System - Same <strong>Seal</strong> on Low <strong>and</strong> High Side ★<br />

<strong>Seal</strong> Fill Fluid Specific Gravity at<br />

77 °F (25 °C)<br />

Temperature Limits (2)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A (3)<br />

Syltherm XLT 0.85 –102 to 293 °F (–75 to 145 °C) ★<br />

C (4)<br />

Silicone 704 1.07 32 to 599 °F (0 to 315 °C) ★<br />

D Silicone 200 0.93 –49 to 401 °F (–45 to 205 °C) ★<br />

H Inert (Halocarbon) 1.85 –49 to 320 °F (–45 to 160 °C) ★<br />

G (5)(6) Glycerin <strong>and</strong> Water 1.13 5 to 203 °F (–15 to 95 °C) ★<br />

N (5)<br />

Neobee M-20 0.92 5 to 437 °F (–15 to 225 °C) ★<br />

P (5)(6)<br />

Propylene Glycol <strong>and</strong> Water 1.02 5 to 203 °F (–15 to 95 °) ★<br />

<strong>Seal</strong> Connection Type / Capillary ID, Description (See descriptions on page 3)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

B 0.03-in. (0.711 mm) ID ★<br />

C 0.04-in. (1.092 mm) ID ★<br />

D 0.075-in. (1.905 mm) ID ★<br />

E 0.03-in. (0.711 mm) ID, PVC Coated ★<br />

F 0.04-in. (1.092 mm) ID, PVC Coated ★<br />

G 0.075-in. (1.905 mm) ID, PVC Coated ★<br />

H 0.03-in. (0.711 mm) ID, 4-in. Support Tube ★<br />

J 0.04-in. (1.092 mm) ID, 4-in. Support Tube ★<br />

K 0.075-in. (1.905 mm) ID, 4-in. Support Tube ★<br />

M (7)<br />

0.03-in. (0.711 mm) ID, PVC Coated, 4-in. Support Tube with Closed End ★<br />

N (7)<br />

0.04-in. (1.092 mm) ID, PVC Coated, 4-in. Support Tube with Closed End ★<br />

P (7)<br />

0.075-in. (1.905 mm) ID, PVC Coated, 4-in. Support Tube with Closed End ★<br />

49


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 15. <strong>Rosemount</strong> <strong>1199</strong> Remote Mount <strong>Seal</strong> <strong>Systems</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

50<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Capillary Length / Direct Mount<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

01 1 ft (0.3 m) ★<br />

05 5 ft (1.5 m) ★<br />

10 10 ft (3.0 m) ★<br />

15 15 ft (4.5 m) ★<br />

20 20 ft (6.1 m) ★<br />

51 1.6 ft (0.5 m) ★<br />

52 3.3 ft (1.0 m) ★<br />

53 4.9 ft (1.5 m) ★<br />

54 6.6 ft (2.0 m) ★<br />

55 8.2 ft (2.5 m) ★<br />

56 9.8 ft (3.0 m) ★<br />

57 11.5 ft (3.5 m) ★<br />

58 13.1 ft (4.0 m) ★<br />

59 16.4 ft (5.0 m) ★<br />

60 19.7 ft (6.0 m) ★<br />

Exp<strong>and</strong>ed<br />

25 25 ft (7.6 m)<br />

30 30 ft (9.1 m)<br />

35 35 ft (10.7 m)<br />

40 40 ft (12.2 m)<br />

45 45 ft (13.7 m)<br />

50 50 ft (15.2 m)<br />

61 23 ft (7.0 m)<br />

62 26.2 ft (8.0 m)<br />

63 29.5 ft (9.0 m)<br />

64 32.8 ft (10.0 m)<br />

65 36.1 ft (11.0 m)<br />

66 39.4 ft (12.0 m)<br />

67 42.6 ft (13.0 m)<br />

68 45.9 ft (14.0 m)<br />

69 49.2 ft (15.0 m)<br />

(1) All welded system connection types require either a 316L SST or Alloy C-276 isolating diaphragm in the pressure transmitter model codes.<br />

(2) At ambient pressure of 14.7 psia (1 bar-a) <strong>and</strong> ambient temperature of 70°F <strong>and</strong> must be further derated if ambient, temperature exceeds 70 °F (21 °C).<br />

(3) Temperature limits are reduced in vacuum service <strong>and</strong> may be limited by seal selection.<br />

(4) Not available with <strong>Seal</strong> Connection Type \ Capillary ID, Description codes B, E, H or M.<br />

(5) This is a food grade fill fluid.<br />

(6) Not suitable for vacuum applications.<br />

(7) Compression fitting does not provide a hermetic seal.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Continue specifying a completed model number by choosing a remote seal type below:<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Flanged <strong>Seal</strong> Assemblies Process Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

page 54 FFW Flush Flanged <strong>Seal</strong> 2-in. / DN 50 / 50A<br />

3-in. / DN 80 / 80A<br />

4-in. / DN 100 / 100A<br />

★<br />

Exp<strong>and</strong>ed<br />

page 57 RFW Flanged <strong>Seal</strong><br />

1<br />

/2-in. / DN 15<br />

3 /4-in.<br />

1-in. / DN 25 / 25A<br />

1 1 /2-in. / DN 40 / 40A<br />

page 60 EFW Extended Flanged <strong>Seal</strong> 1 1 /2-in. / DN 40 / 40A<br />

2-in. / DN 50 / 50A<br />

3-in. / Headbox<br />

/ DN 80 / 80A<br />

4-in. / Headbox<br />

/ DN 100 / 100A<br />

page 63 PFW Pancake <strong>Seal</strong> 2-in. / DN50<br />

3-in. / DN 80<br />

page 65 FCW Flush Flanged <strong>Seal</strong> – Ring Type Joint (RTJ) Gasket Surface 2-in.<br />

3-in.<br />

page 67 RCW Ring Type Joint (RTJ) Flanged <strong>Seal</strong> ½-in.<br />

¾-in.<br />

1-in.<br />

1 ½-in.<br />

page 69 FUW <strong>and</strong> FVW Flush Flanged Type <strong>Seal</strong>s DN 50<br />

DN 80<br />

Threaded <strong>Seal</strong> Assemblies Process Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

page 70 RTW Threaded <strong>Seal</strong> ¼ –18 NPT<br />

3<br />

/8 –18 NPT<br />

½ –14 NPT<br />

¾ –14 NPT<br />

1 – 11.5 NPT<br />

1 ¼ –11.5 NPT<br />

1 ½ –11.5 NPT<br />

G1 /2 A DIN 16288<br />

R1 /2 per ISO 7/1<br />

★<br />

Exp<strong>and</strong>ed<br />

page 73 HTS Male Threaded <strong>Seal</strong> G1<br />

G1 ½<br />

G2<br />

1-11.5 NPT<br />

1 ½ -11.5 NPT<br />

2-11.5 NPT<br />

★<br />

★<br />

★<br />

51


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

52<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Hygienic <strong>Seal</strong> Assemblies Process Connections<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

page 74 SCW Hygienic Tri-Clover Style Tri-Clamp <strong>Seal</strong> 1 ½-in.<br />

2-in.<br />

2 ½-in.<br />

3-in.<br />

4-in.<br />

★<br />

Exp<strong>and</strong>ed<br />

page 76 SSW Hygienic Tank Spud <strong>Seal</strong> 2-in. Extension<br />

6-in. Extension<br />

page 78 STW Hygienic Thin Wall Tank Spud <strong>Seal</strong> 0.8 in Extension<br />

page 79 EES Hygienic Flanged Tank Spud Extended <strong>Seal</strong> DN 50<br />

DN 80<br />

page 80 VCS Tri-clamp ® In-Line <strong>Seal</strong> 1-in.<br />

1 ½-in.<br />

2-in.<br />

3-in.<br />

4-in.<br />

page 81 SVS Varivent ® Compatible Hygienic Connection <strong>Seal</strong> Tuchenhagen Varivent<br />

Compatible<br />

page 82 SHP Hygienic Cherry-Burrell “I” Line <strong>Seal</strong> 2-in.<br />

3-in.<br />

page 83 SLS Dairy Process Connection - Female Thread <strong>Seal</strong> per DIN 11851 DN 40<br />

DN 50<br />

Specialty <strong>Seal</strong> Assemblies<br />

Exp<strong>and</strong>ed<br />

Process Connections<br />

page 84 WSP Saddle <strong>Seal</strong> 2-in.<br />

3-in.<br />

4-in. or Larger<br />


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

page 85 UCP Male Threaded Pipe Mount <strong>Seal</strong>s <strong>and</strong> PMW Paper Mill Sleeve<br />

<strong>Seal</strong>s<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

page 86 CTW Chemical Tee <strong>Seal</strong> Retro-fit<br />

1 ½-in. with Threaded<br />

Knurled Nut<br />

1-in. with Cap Screw<br />

Retainer<br />

page 87 TFS Wafer Style In-Line <strong>Seal</strong> 1-in. / DN 25<br />

1 ½-in. / DN 40<br />

2-in. / DN 50<br />

3-in. / DN 80<br />

4-in. / DN 100<br />

page 88 WFW Flow-Thru Flanged <strong>Seal</strong> 1-in.<br />

2-in.<br />

3-in.<br />

53


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

54<br />

FFW FLUSH FLANGED SEAL<br />

Flanged <strong>Seal</strong>s<br />

Table 16. FFW Flush Flanged <strong>Seal</strong> – Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ards<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers) ★<br />

D EN 1092-1 (European St<strong>and</strong>ard) ★<br />

T<br />

Exp<strong>and</strong>ed<br />

GOST 12815-80 (Russian St<strong>and</strong>ard) ★<br />

J JIS B2238 (Japanese Industrial St<strong>and</strong>ard)<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

FFW Flush Flanged <strong>Seal</strong> ★<br />

Process Connection Size<br />

ANSI/ASME B16.5 EN 1092-1 / GOST 12815-80 JIS B2238<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

G 2-in. DN 50 50 A ★<br />

7 3-in. — 80 A ★<br />

J — DN 80 — ★<br />

9 4-in. DN 100 100 A ★<br />

Flange / Pressure Rating<br />

ANSI/ASME B16.5 EN 1092-1 / GOST 12815-80 JIS B2238<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Class 150 — 10K ★<br />

2 Class 300 — 20K ★<br />

4 Class 600 — 40K ★<br />

G<br />

Exp<strong>and</strong>ed<br />

— PN 40 — ★<br />

E — PN 10 / 16 (DN 100 only) —<br />

5 Class 900 — —<br />

6 Class 1500 — —<br />

7 Class 2500 — —<br />

H — PN 63 —<br />

J — PN 100 —<br />

K — PN 160 —<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing, Flange Material<br />

Diaphragm <strong>and</strong> Wetted Upper Housing Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

CA (1)(2) 316L SST 316L SST CS ★<br />

DA (2)<br />

316L SST 316L SST 316 SST ★<br />

CB (1)(3) Alloy C-276, seam welded 316L SST CS ★<br />

DB (3) Alloy C-276, seam welded 316L SST 316 SST ★<br />

CC (1)<br />

Tantalum, seam welded 316L SST CS ★<br />

DC Tantalum, seam welded 316L SST 316 SST ★<br />

C3 (1)(2)(3)(4) Tantalum, brazed 316L SST CS ★<br />

D3 (1)(2)(3)(4) Tantalum, brazed 316L SST 316 SST ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Exp<strong>and</strong>ed<br />

MB (1)(2) Alloy C-276, solid faceplate Alloy C-276 / 316L SST CS<br />

KB (1)(2)<br />

Alloy C-276, solid faceplate Alloy C-276 / 316L SST 316 SST<br />

DJ Alloy B 316L SST 316 SST<br />

DF 304L SST 316L SST 316 SST<br />

DV Alloy 400 316L SST 316 SST<br />

RH (2) (5) Titanium Grade 4 Titanium GR.4 316 SST<br />

DH (6) Titanium Grade 4 316L SST 316 SST<br />

DE Alloy 600 316L SST 316 SST<br />

<strong>DP</strong> Nickel 201 316L SST 316 SST<br />

WW (2)(7) 316Ti SST (WNr 1.4571) 316Ti SST (WNr 1.4571) 316Ti SST (WNr 1.4571)<br />

DZ (6)<br />

Zirconium 702 316L SST 316 SST<br />

D4 Alloy C-22 316L SST 316 SST<br />

D5 Duplex 2507 SST 316L SST 316 SST<br />

Flushing Connection Ring Material (Lower Housing) (8)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 None ★<br />

A 316L SST ★<br />

B<br />

Exp<strong>and</strong>ed<br />

Alloy C-276 ★<br />

2 Duplex 2205 SST<br />

H Titanium Grade 4<br />

6 Nickel 201<br />

V Alloy 400<br />

Flushing Connection Options, Quantity (Size)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 None ★<br />

1 1 ( 1 /4-18 NPT) ★<br />

3 2 ( 1 /4-18 NPT) ★<br />

7 1 ( 1 /2-14 NPT) ★<br />

9 2 ( 1 Table 16. FFW Flush Flanged <strong>Seal</strong> – Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

/2-14 NPT) ★<br />

Options (Include with selected model number)<br />

Gasket Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

J<br />

Exp<strong>and</strong>ed<br />

PTFE gasket (for use with flushing connection ring) ★<br />

N Grafoil gasket (for use with flushing connection ring)<br />

K Barium Sulfate filled PTFE gasket (for use with flushing connection ring)<br />

Flushing Plug, Vent/Drain Valve<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D Alloy C-276 plug(s) for flushing connection(s) ★<br />

G 316 SST plug(s) for flushing connection(s) ★<br />

H 316 SST vent/drain for flushing connection(s) ★<br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 µm) available with 316L SST, Alloy C-276, <strong>and</strong> Duplex 2507 SST for abrasive applications<br />

7 0.002-in. (50 µm) available with 316L SST <strong>and</strong> Alloy C-276<br />

Mounting Flange<br />

Exp<strong>and</strong>ed<br />

4 (9)<br />

Flat face, flush flanged<br />

55


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

56<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T (10)<br />

Table 16. FFW Flush Flanged <strong>Seal</strong> – Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103 ★<br />

Gasket Surface Finish<br />

Exp<strong>and</strong>ed<br />

1 Gasket Surface Ra 125 Max.<br />

Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

B Extra Fill For Cold Temp Application ★<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

U (11)<br />

0.001-in. ±0.0002-in. (25 µm ±5 µm) gold plated Diaphragm<br />

V (11)(12) PTFE coated diaphragm for nonstick purposes only<br />

Capillary Change<br />

Exp<strong>and</strong>ed<br />

2 Radial capillary connection<br />

Alternate Design<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

E One Piece Design ★<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A FFW 7 1 DA 0 0<br />

(1) Only available with two piece design.<br />

(2) For use with spiral wound metallic gaskets.<br />

(3) Not available with option code C.<br />

(4) Only available in Process Connection Size code G, 7, <strong>and</strong> J.<br />

(5) Not available with welded capillary connections or direct mount.<br />

(6) Operating temperature limited to 302 °F (150 °C).<br />

(7) Only available with one-piece design, option code E.<br />

(8) Supplied st<strong>and</strong>ard with ThermoTork TN9000.<br />

(9) The mounting flange <strong>and</strong> upper housing are a single item for the one-piece design. Only available with diaphragm <strong>and</strong> wetted part material codes DA, DB,<br />

DJ, DF, DV, DH, DE, <strong>DP</strong>, WW, DZ, D4, DC, <strong>and</strong> D5.<br />

(10) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(11) Only available on 316LSS, Alloy 400 <strong>and</strong> Alloy C-276.<br />

(12) Not available with transmitter option code Q8, for Material Traceability per EN 10204 3.1 of the transmitter / seal assembly.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

RFW FLANGED SEAL<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 17. RFW Flanged <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers) ★<br />

D EN 1092-1 (European St<strong>and</strong>ard) ★<br />

T<br />

Exp<strong>and</strong>ed<br />

GOST 12815-80 (Russian St<strong>and</strong>ard) ★<br />

J JIS B2238 (Japanese Industrial St<strong>and</strong>ard)<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

RFW Flanged <strong>Seal</strong> ★<br />

Process Connection Size<br />

ANSI/ASME B16.5 EN 1092-1 / GOST 12815-80 JIS B2238<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 1-in. — 25A ★<br />

4 1 1 /2-in. — 40A ★<br />

D — DN 25 — ★<br />

F<br />

Exp<strong>and</strong>ed<br />

— DN 40 — ★<br />

1 1 /2-in. — —<br />

A 3 /4-in. DN 10 10A<br />

B — DN 15 15A<br />

C — DN 20 20A<br />

Flange/Pressure Rating<br />

ANSI/ASME B16.5 EN 1092-1 / GOST 12815-80 JIS B2238<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Class 150 — 10K ★<br />

2 Class 300 — 20K ★<br />

4 Class 600 — 40K ★<br />

G<br />

Exp<strong>and</strong>ed<br />

— PN 40 — ★<br />

5 Class 900 — —<br />

6 Class 1500 — —<br />

7 Class 2500 — —<br />

C — PN 6 —<br />

H — PN 63 —<br />

J — PN 100 —<br />

K — PN 160 —<br />

Diaphragm, Upper Housing, Flange Material<br />

Diaphragm Upper Housing Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

CA 316L SST 316L SST CS ★<br />

DA 316L SST 316L SST 316 SST ★<br />

CB Alloy C-276 316L SST CS ★<br />

DB Alloy C-276 316L SST 316 SST ★<br />

CC Tantalum 316L SST CS ★<br />

DC Tantalum 316L SST 316 SST ★<br />

57


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

58<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Exp<strong>and</strong>ed<br />

DF 304L SST 316L SST 316 SST<br />

DJ Alloy B 316L SST 316 SST<br />

DE Alloy 600 316L SST 316 SST<br />

DV Alloy 400 316L SST 316 SST<br />

<strong>DP</strong> Nickel 201 316L SST 316 SST<br />

DK Alloy 20 316L SST 316 SST<br />

RH (1) Titanium Grade 4 Titanium Grade 4 316 SST<br />

DH Titanium Grade 4 316L SST 316 SST<br />

D4 Alloy C-22 316L SST 316 SST<br />

D5 Duplex 2507 SST 316L SST 316 SST<br />

DZ Zirconium 702 316L SST 316 SST<br />

Flushing Connection Ring Material (Lower Housing) (2)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 316L SST ★<br />

B Alloy C-276 ★<br />

D<br />

Exp<strong>and</strong>ed<br />

Plated CS ★<br />

2 Duplex 2205<br />

F 304L SST<br />

H Titanium Grade 4<br />

V Alloy 400<br />

C Tantalum lined 316L SST (no flushing connection allowed)<br />

Flushing Connection Options, Quantity Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

5 None ★<br />

1 1 ( 1 /4-18 NPT) ★<br />

3 2 ( 1 Exp<strong>and</strong>ed<br />

/4-18 NPT) ★<br />

7 1 ( 1 /2-14 NPT)<br />

9 2 ( 1 /2-14 NPT)<br />

Options (Include with selected model number)<br />

Gasket Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

J<br />

Exp<strong>and</strong>ed<br />

PTFE gasket ★<br />

N Grafoil ® gasket<br />

K Barium Sulfate filled PTFE gasket<br />

R Ethylene Propylene gasket<br />

Flushing Plug, Vent/Drain Valve<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D Alloy C-276 plug(s) for flushing connection(s) ★<br />

G 316 SST plug(s) for flushing connection(s) ★<br />

H 316 SST vent/drain for flushing connection(s) ★<br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 µm) available with 316L SST, Alloy C-276, <strong>and</strong> Duplex 2507 SST for abrasive applications<br />

Bolt Material<br />

Exp<strong>and</strong>ed<br />

3 304 SST Bolts (Only available for Stud Bolt Design)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T (3) Table 17. RFW Flanged <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103 ★


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Gasket Surface Finish<br />

Exp<strong>and</strong>ed<br />

1 Gasket Surface Ra 125 Max.<br />

Cold Temperature Application<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

B Extra Fill For Cold Temp Application ★<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

U (4)<br />

0.001-in. ±0.0002-in. (25 µm ±5 µm) Gold plated diaphragm<br />

V (4)(5) Table 17. RFW Flanged <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

PTFE coated diaphragm for nonstick purposes only<br />

Large Diaphragm Size<br />

Exp<strong>and</strong>ed<br />

9 4.1-in. (104 mm) Diaphragm Diameter<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A RFW 2 1 DA A 5<br />

(1) Not available with welded capillary connections or direct mount.<br />

(2) Supplied with C4401 Aramid fiber gasket.<br />

(3) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(4) Only available on 316LSS, Alloy 400 <strong>and</strong> Alloy C-276.<br />

(5) Not available with transmitter option code Q8, for Material Traceability per EN 10204 3.1 of the transmitter / seal assembly.<br />

59


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

60<br />

EFW EXTENDED FLANGED SEAL<br />

Table 18. EFW Extended Flanged <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Code Industry St<strong>and</strong>ard ● = Available<br />

— =<br />

Unavailable<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers) ★<br />

D EN 1092-1 (European St<strong>and</strong>ard) ★<br />

T<br />

Exp<strong>and</strong>ed<br />

GOST 12815-80 (Russian St<strong>and</strong>ard) ★<br />

J JIS B2238 (Japanese Industrial St<strong>and</strong>ards)<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

EFW Extended Flanged <strong>Seal</strong> ★<br />

Process Connection Size<br />

ANSI/ASME B16.5 EN 1092-1 / GOST 12815-80 JIS B2238 Extension<br />

Diameters<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

7 3-in. Schedule 80 DN 80 80A 2.58-in. (66 mm) ★<br />

9<br />

Exp<strong>and</strong>ed<br />

4-in. Schedule 80 DN 100 100A 3.50-in. (89 mm) ★<br />

4 1 1 /2-in. DN 40 40A 1.45-in. (37 mm)<br />

G 2-in. DN 50 50A 1.90-in. (48 mm)<br />

H 3-in. (Headbox) DN 80 (Headbox) — 2.875-in. (73 mm)<br />

K 4-in. (Headbox) DN 100 (Headbox) 3.780-in. (96 mm)<br />

R 3-in. Schedule 40 DN 80 80A 2.85-in. (73 mm)<br />

T 4-in.(Schedule 40) DN 100 100A 3.70-in. (94 mm)<br />

Flange/Pressure Rating<br />

ANSI/ASME B16.5 EN 1092-1 / GOST 12815-80 JIS B2238<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Class 150 — 10K ★<br />

2 Class 300 — 20K ★<br />

4 Class 600 — 40K ★<br />

G<br />

Exp<strong>and</strong>ed<br />

— PN 40 — ★<br />

E — PN 10/16 (DN 100 only) —<br />

5 Class 900 — —<br />

6 Class 1500 — —<br />

7 Class 2500 — —<br />

H — PN 63 —<br />

J — PN 100 —<br />

K — PN 160 —<br />

J — PN 100 —<br />

K — PN 160 —


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 18. EFW Extended Flanged <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Diaphragm, Extension <strong>and</strong> Gasket Surface, Upper Housing, Flange Material Available with Process<br />

Connection Code<br />

Code Diaphragm Extension/<br />

Gasket Surface<br />

Upper<br />

Housing<br />

Mounting<br />

Flange 7 9 4 G H K<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

DA 316L SST 316L SST 316L SST 316 SST ● ● ● ● ● ● ★<br />

CA 316L SST 316L SST 316L SST CS ● ● ● ● ● ● ★<br />

DB Alloy C-276 Alloy C-276 316L SST 316 SST ● ● ● ● ● ● ★<br />

CB<br />

Exp<strong>and</strong>ed<br />

Alloy C-276 Alloy C-276 316L SST CS ● ● ● ● ● ● ★<br />

DM Alloy C-276 316L SST 316L SST 316 SST ● ● ● ● ● ●<br />

DD Tantalum 316L SST 316L SST 316 SST ● ● — — — —<br />

DC (1)<br />

Tantalum Tantalum Lined 316L SST 316 SST ● ● — ● — —<br />

D5 Duplex 2507 SST Duplex 2205 SST 316L SST 316 SST ● ● ● ● ● ●<br />

D9 Duplex 2507 SST 316L SST 316L SST 316 SST ● ● ● ● ● ●<br />

Extension Length<br />

ANSI/ASME B16.5 EN 1092-1 / JIS B2238 / GOST 12815-80<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 2-in. 50 mm ★<br />

4 4-in. 100 mm ★<br />

6<br />

Exp<strong>and</strong>ed<br />

6-in. 150 mm ★<br />

8 8-in. 200 mm<br />

1 1-in. 25 mm<br />

3 3-in. 75 mm<br />

5 5-in. 125 mm<br />

7 7-in. 175 mm<br />

9 9-in. 225 mm<br />

Fractional Extension Length<br />

ANSI/ASME B16.5 EN 1092-1 / JIS B2238 / GOST 12815-80<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 0-in. 0 mm ★<br />

Options (Include with selected model number)<br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 µm) available with 316L SST, Alloy C-276, <strong>and</strong> Duplex 2507 SST for abrasive applications<br />

Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T (2)<br />

Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103 ★<br />

Gasket Surface Finish<br />

Exp<strong>and</strong>ed<br />

1 Gasket Surface Ra 125 Max.<br />

Cold Temperature Application<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

B Extra Fill For Cold Temperature Application ★<br />

61


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

U (3)<br />

0.001-in. ±0.0002-in. (25 µm ±5 µm) Gold plated diaphragm<br />

V (3)(4) Table 18. EFW Extended Flanged <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

PTFE coated diaphragm for nonstick purposes only<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A EFW 7 1 DA 2 0<br />

62<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(1) Requires Gasket Surface Finish Code 1 Gasket Surface Finish Ra 125 Max. Available in extension lengths 2, 4 & 6 in. For all other lengths consult factory.<br />

(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(3) Only available on 316LSS, Alloy 400 <strong>and</strong> Alloy C-276.<br />

(4) Not available with transmitter option code Q8, for Material Traceability per EN 10204 3.1 of the transmitter / seal assembly.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

PFW PANCAKE SEAL<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 19. PFW Pancake <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers) ★<br />

D EN 1092-1 (European St<strong>and</strong>ard) ★<br />

T GOST 12815-80 (Russian St<strong>and</strong>ard) ★<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

PFW Pancake <strong>Seal</strong> ★<br />

Process Connection Size<br />

ANSI EN 1092-1 / GOST 12815-80<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

G 2-in. DN 50 ★<br />

7 3-in. — ★<br />

J — DN 80 ★<br />

Flange/Pressure Rating<br />

ANSI EN 1092-1 / GOST 12815-80<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 No flange supplied, seal MWP based on customer supplied flange ★<br />

1 Class 150 — ★<br />

2 Class 300 — ★<br />

4 Class 600 — ★<br />

G<br />

Exp<strong>and</strong>ed<br />

— PN40 ★<br />

5 Class 900 —<br />

6 Class 1500 —<br />

7 Class 2500 —<br />

H — PN 63<br />

J — PN 100<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing, Flange Material<br />

Diaphragm <strong>and</strong> Wetted Upper Housing Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

LA (1)<br />

316L SST 316L SST None ★<br />

CA (1) 316L SST 316L SST CS ★<br />

DA (1) 316L SST 316L SST 316 SST ★<br />

LB Alloy C-276, Seam Welded 316L SST None ★<br />

CB Alloy C-276, Seam Welded 316L SST CS ★<br />

DB Alloy C-276, Seam Welded 316L SST 316 SST ★<br />

LC Tantalum, Seam Welded 316L SST None ★<br />

CC Tantalum, Seam Welded 316L SST CS ★<br />

DC Tantalum, Seam Welded 316L SST 316 SST ★<br />

Flushing Connection Ring Material (Lower Housing) (2)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 None ★<br />

A 316L SST ★<br />

B Alloy C-276 ★<br />

63


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

64<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Flushing Connection Options, Quantity (Size)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 None ★<br />

1 1 ( 1 /2-14 NPT) ★<br />

2 2 ( 1 /2-14 NPT) ★<br />

7 1 ( 1 /2-14 NPT) ★<br />

9 2 ( 1 /2-14 NPT) ★<br />

Options (Include with selected model number)<br />

Gasket Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

J<br />

Exp<strong>and</strong>ed<br />

PTFE gasket ★<br />

N Grafoil ® Table 19. PFW Pancake <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

gasket<br />

K Barium Sulfate filled PTFE gasket<br />

Flushing Plug, Vent/Drain Valve<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D Alloy C-276 plug(s) for flushing connection(s) ★<br />

G 316 SST plug(s) for flushing connection(s) ★<br />

H 316 SST vent/drain for flushing connection(s) ★<br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 µm) available with 316L SST, Alloy C-276, <strong>and</strong> Duplex 2507 SST for abrasive applications<br />

Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T (3) Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103 ★<br />

Gasket Surface Finish<br />

Exp<strong>and</strong>ed<br />

1 Gasket Surface Ra 125 Max.<br />

Cold Temperature Application<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

B Extra Fill For Cold Temp Application ★<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

U (4) 0.001-in. ±0.0002-in. (25 µm ±5 µm) Gold plated diaphragm<br />

V (4)(5)<br />

PTFE coated diaphragm for nonstick purposes only<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A PFW 7 1 DA 0 0<br />

(1) For use with customer supplied spiral wound metallic gaskets.<br />

(2) Supplied st<strong>and</strong>ard with Thermo Torque TN9000 gasket.<br />

(3) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(4) Only available on 316LSS, Alloy 400, <strong>and</strong> Alloy C-276.<br />

(5) Not available with transmitter option code Q8, for Material Traceability per EN 10204 3.1 of the transmitter / seal assembly.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

FCW FLUSH FLANGED SEAL – RING TYPE JOINT (RTJ) GASKET SURFACE<br />

Table 20. FCW Flush Flanged <strong>Seal</strong> – Ring Type Joint (RTJ) Gasket Surface Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ards<br />

Exp<strong>and</strong>ed<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

FCW Flush Flanged <strong>Seal</strong> - Ring Type Joint Gasket Surface<br />

Process Connection Size<br />

Exp<strong>and</strong>ed<br />

G 2-in.<br />

7 3-in.<br />

Flange/Pressure Rating<br />

Exp<strong>and</strong>ed<br />

1 Class 150<br />

2 Class 300<br />

4 Class 600<br />

5 Class 900<br />

6 Class 1500<br />

7 Class 2500<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing, Flange Material<br />

Diaphragm <strong>and</strong> Wetted Upper Housing Flange<br />

Exp<strong>and</strong>ed<br />

DA 316L SST 316L SST 316 SST<br />

KB Alloy C-276 316L SST 316 SST<br />

K5 Duplex 2507 SST/Duplex 2205 316L SST 316 SST<br />

Flushing Connection Ring Material (Lower Housing)<br />

Exp<strong>and</strong>ed<br />

0 None<br />

A 316L SST<br />

B Alloy C-276<br />

2 Duplex 2205 SST<br />

Flushing Connection Options<br />

Exp<strong>and</strong>ed<br />

0 None<br />

1 1 ( 1 /4-18 NPT)<br />

3 2 ( 1 /4-18 NPT)<br />

7 1 ( 1 /2-14 NPT)<br />

9 2 ( 1 /2-14 NPT)<br />

Options (Include with selected model number)<br />

Flushing Plug, Vent/Drain Valve<br />

Exp<strong>and</strong>ed<br />

D Alloy C-276 plug(s) for flushing connection(s)<br />

G 316 SST plug(s) for flushing connection(s)<br />

H 316 SST vent/drain for flushing connection(s)<br />

65


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 µm) available with 316L SST, Alloy C-276, <strong>and</strong> Duplex 2507 SST for abrasive applications<br />

7 0.002-in. (50 µm) available with 316L SST <strong>and</strong> Alloy C-276<br />

Code Conformance<br />

Exp<strong>and</strong>ed<br />

T (1)<br />

Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103<br />

Cold Temp Application<br />

Exp<strong>and</strong>ed<br />

B Extra Fill For Cold Temp Application<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

U (2)<br />

0.001-in. ±0.0002-in. (25 µm ±5 µm) Gold plated diaphragm<br />

V (2)(3) Table 20. FCW Flush Flanged <strong>Seal</strong> – Ring Type Joint (RTJ) Gasket Surface Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

PTFE coated diaphragm for nonstick purposes only<br />

Alternate Design<br />

Exp<strong>and</strong>ed<br />

E One Piece Design<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A FCW 7 1 DA 0 0<br />

66<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(2) Only available on 316LSS <strong>and</strong> Alloy C-276.<br />

(3) Not available with transmitter option code Q8, for Material Traceability per EN 10204 3.1 of the transmitter / seal assembly.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

RCW RING TYPE JOINT (RTJ) FLANGED SEAL<br />

Table 21. RCW Ring Type Joint Flanged <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Exp<strong>and</strong>ed<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

RCW Flanged <strong>Seal</strong> - Ring Type Joint Gasket Surface<br />

Process Connection Size<br />

Exp<strong>and</strong>ed<br />

1 1<br />

/2-in. (Bolts <strong>and</strong> studs included for ANSI Class 300 to 1500, not available for ANSI Class 150)<br />

3 A<br />

/4-in. (Not available for Class 150)<br />

2 1-in.<br />

4 11 /2-in.<br />

Flange/Pressure Rating<br />

Exp<strong>and</strong>ed<br />

1 Class 150<br />

2 Class 300<br />

4 Class 600<br />

5 Class 900<br />

6 Class 1500<br />

7 Class 2500<br />

Diaphragm, Upper Housing, Flange Material<br />

Diaphragm Upper Housing Flange<br />

Exp<strong>and</strong>ed<br />

DA 316L SST 316L SST 316 SST<br />

DB Alloy C-276 316L SST 316 SST<br />

DC Tantalum 316L SST 316 SST<br />

DE Alloy 600 316L SST 316 SST<br />

DF 304L SST 316L SST 316 SST<br />

DJ Alloy B316L SST 316L SST 316 SST<br />

DV Alloy 400 316L SST 316 SST<br />

<strong>DP</strong> Nickel 201 316L SST 316 SST<br />

RH Titanium Grade 4 Titanium Grade 4 316 SST<br />

DH (1) Titanium Grade 4 316L SST 316 SST<br />

D4 Alloy 22 316L SST 316 SST<br />

D5 Duplex 2507 SST 316L SST 316 SST<br />

DZ (1) Zirconium 702 316L SST 316 SST<br />

DK Alloy 20 316L SST 316 SST<br />

Flushing Connection Ring Material (Lower Housing)<br />

Exp<strong>and</strong>ed<br />

A 316L SST<br />

B Alloy C-276<br />

F 304L SST<br />

H Titanium Grade 4<br />

2 Duplex 2205 SST<br />

V Alloy 400<br />

67


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Flushing Connection Options<br />

Exp<strong>and</strong>ed<br />

5 None<br />

1 1 ( 1 /4-18 NPT)<br />

3 2 ( 1 /4-18 NPT)<br />

7 1 ( 1 /2-14 NPT)<br />

9 2 ( 1 Table 21. RCW Ring Type Joint Flanged <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

/2-14 NPT)<br />

Options (Include with selected model number)<br />

Gasket Material<br />

Exp<strong>and</strong>ed<br />

J PTFE gasket<br />

N Grafoil ® gasket<br />

K Barium Sulfate filled PTFE gasket<br />

R Ethylene Propylene gasket<br />

Flushing Plug, Vent/Drain Valve<br />

Exp<strong>and</strong>ed<br />

D Alloy C-276 plug(s) for flushing connection(s)<br />

G 316 SST plug(s) for flushing connection(s)<br />

H 316 SST vent/drain for flushing connection(s)<br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 µm) available with 316L SST, Alloy C-276, <strong>and</strong> Duplex 2507 SST for abrasive applications<br />

Bolt Material (Optional)<br />

Exp<strong>and</strong>ed<br />

3 304 SST Bolts (Only available for Stud Bolt Design)<br />

Code Conformance<br />

Exp<strong>and</strong>ed<br />

T (2) Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103<br />

Cold Temperature Application<br />

Exp<strong>and</strong>ed<br />

B Extra Fill For Cold Temp Application<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

U (3) 0.001-in. ±0.0002-in. (25 µm ±5 µm) Gold plated diaphragm<br />

V (3)(4) PTFE coated diaphragm for nonstick purposes only<br />

Large Diaphragm Size<br />

Exp<strong>and</strong>ed<br />

9 4.1-in. (104 mm) Diaphragm Diameter<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A RCW 2 1 DA A 5<br />

68<br />

(1) Operating temperature is limited to 302 °F (150 °C).<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(3) Only available on 316LSS, Alloy 400, <strong>and</strong> Alloy C-276.<br />

(4) Not available with transmitter option code Q8, for Material Traceability per EN 10204 3.1 of the transmitter / seal assembly.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

FUW AND FVW FLUSH FLANGED TYPE SEALS<br />

Table 22. FUW <strong>and</strong> FVW Flush Flanged Type <strong>Seal</strong>s – EN Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

Exp<strong>and</strong>ed<br />

D EN 1092-1 (European St<strong>and</strong>ard)<br />

T GOST 12815-80 (Russian St<strong>and</strong>ard)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

FUW Flush Flanged, EN 1092-1 Type D (Groove)<br />

FVW Flush Flanged, EN 1092-1 Type C (Tongue)<br />

Process Connection Size<br />

Exp<strong>and</strong>ed<br />

G DN 50<br />

J DN 80<br />

Flange/Pressure Rating<br />

Exp<strong>and</strong>ed<br />

G PN 40<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing, Flange Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing Flange<br />

DA (1) 316L SST 316L SST 316 SST<br />

KB (2)<br />

Alloy C-276 316L SST 316 SST<br />

DC (1) Tantalum 316L SST 316 SST<br />

Flushing Connection Ring Material (Lower Housing)<br />

Exp<strong>and</strong>ed<br />

0 None<br />

Flushing Connection Options, Quantity (Size)<br />

Exp<strong>and</strong>ed<br />

0 None<br />

Options (Include with selected model number)<br />

Cold Temperature Application<br />

Exp<strong>and</strong>ed<br />

B Extra Fill For Cold Temperature Application<br />

Alternate Design<br />

Exp<strong>and</strong>ed<br />

E One Piece Design<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A FUW J G DA 0 0<br />

(1) Only available with one piece design, option code E.<br />

(2) Only available with two-piece design.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

69


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

70<br />

RTW THREADED SEAL<br />

Threaded <strong>Seal</strong>s<br />

Table 23. RTW Threaded <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A ANSI/ASME B1.20.1 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers ★<br />

D EN 10226-1 (European St<strong>and</strong>ard) ★<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

RTW Threaded (st<strong>and</strong>ard thread is female, for male select Option code 9) ★<br />

Process Connection Size<br />

ANSI/ASME B1.20.1 EN 10226-1<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

3<br />

1<br />

/2-14 NPT — ★<br />

4 3 /4-14 NPT — ★<br />

5 1-11.5 NPT — ★<br />

7 (1)<br />

1 1 Exp<strong>and</strong>ed<br />

/2-11.5 NPT — ★<br />

1 1 /4-18 NPT —<br />

C — Parallel thread: G 1 /2A DIN 16288<br />

2 3 /8-18 NPT —<br />

6 (1)<br />

1 1 /4-11.5 NPT —<br />

N — Tapered thread: R1 /2 per ISO 7/1<br />

Pressure Rating<br />

ANSI/ASME B1.20.1 EN 10226-1<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

0 2500 psi 172 bar ★<br />

Exp<strong>and</strong>ed<br />

2 (2) 5000 psi 344 bar<br />

3 (2)(3) 10000 psi —<br />

8 1500 psi (4.1-in. (104 mm) diaphragm 103 bar (4.1-in. (104 mm) diaphragm<br />

Diaphragm, Upper Housing, Flange Material<br />

Diaphragm Upper Housing Flange<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

CA 316L SST 316L SST CS ★<br />

DA 316L SST 316L SST 316 SST ★<br />

CB Alloy C-276 316L SST CS ★<br />

DB Alloy C-276 316L SST 316 SST ★<br />

CC Tantalum 316L SST CS ★<br />

DC Tantalum 316L SST 316 SST ★<br />

Exp<strong>and</strong>ed<br />

DJ Alloy B 316L SST 316 SST<br />

DF 304L SST 316L SST 316 SST<br />

<strong>DP</strong> Nickel 201 316L SST 316 SST<br />

DV Alloy 400 316L SST 316 SST<br />

RH (4)<br />

Titanium Grade 4 Titanium Grade 4 316 SST<br />

DH (5) Titanium Grade 4 316L SST 316 SST


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

D4 Alloy 22 316L SST 316 SST<br />

D5 Duplex 2507 SST 316L SST 316 SST<br />

DE Alloy 600 316L SST 316 SST<br />

DZ (5) Zirconium 702 316L SST 316 SST<br />

DK Alloy 20 316L SST 316 SST<br />

RZ (4)<br />

Zirconium 702 Zirconium 702 316 SST<br />

Flushing Connection Ring Material (Lower Housing) (6)(7)<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 316L SST ★<br />

B<br />

Exp<strong>and</strong>ed<br />

Alloy C-276 ★<br />

D Plated Carbon Steel<br />

2 Duplex 2205 SST<br />

H Titanium Grade 4<br />

V Alloy 400<br />

F 304L SST<br />

Flushing Connection Options<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

5 None ★<br />

1 1 ( 1 /4-18 NPT) ★<br />

3 2 ( 1 Exp<strong>and</strong>ed<br />

/4-18 NPT) ★<br />

7 1 ( 1 /2-14 NPT)<br />

9 2 ( 1 Table 23. RTW Threaded <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

/2-14 NPT)<br />

Options (Include with selected model number)<br />

Gasket Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

J PTFE gasket (for use with flushing connection ring) ★<br />

N Grafoil ® gasket (for use with flushing connection ring) ★<br />

R<br />

Exp<strong>and</strong>ed<br />

Ethylene Propylene gasket (for use with flushing connection ring) ★<br />

K Barium Sulfate filled PTFE gasket (for use with flushing connection ring)<br />

Flushing Plug, Vent/Drain Valve<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

D Alloy C-276 plug(s) for flushing connection(s) ★<br />

G 316 SST plug(s) for flushing connection(s) ★<br />

H 316 SST vent/drain for flushing connection(s) ★<br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 µm) available with 316L SST, Alloy C-276, <strong>and</strong> Duplex 2507 SST for abrasive applications<br />

Bolt Material<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

3<br />

Exp<strong>and</strong>ed<br />

304 SST Bolts ★<br />

4 316 SST Bolts<br />

Code Conformance<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

T (8) Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103 ★<br />

Cold Temperature Application<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

B Extra Fill For Cold Temp Application ★<br />

71


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

U (9)<br />

0.001-in. ±0.0002-in. (25 µm ±5 µm) Gold plated diaphragm<br />

V (9)(10) Table 23. RTW Threaded <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

PTFE coated diaphragm for nonstick purposes only<br />

Special Threads in Lower Housing<br />

Exp<strong>and</strong>ed<br />

9 Male Threads<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A RTW 3 0 DA A 5<br />

72<br />

(1) Flushing connection not available.<br />

(2) Consult an Emerson Process Management representative for pricing <strong>and</strong> availability on Pressure Rating codes 2 or 3.<br />

(3) The following process connection sizes are D rated: 3 /4-in (9000 psi/621 bar), 1-in. (8700 psi/600 bar), 1 1 /4-in (7000 psi/483 bar), <strong>and</strong><br />

1 1 /2-in. (6000 psi/414 bar).<br />

(4) Not available with welded capillary connections or direct mount.<br />

(5) Operating temperature is limited to 302 °F (150 °C).<br />

(6) Supplied with C4401 aramid fiber gasket.<br />

(7) Flushing Connection Ring/ Lower Housing assembly bolts provided as st<strong>and</strong>ard are carbon steel for ANSI <strong>and</strong> 304 SST for EN.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(8) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(9) Only available on 316LSS, Alloy 400, <strong>and</strong> Alloy C-276.<br />

(10) Not available with transmitter option code Q8, for Material Traceability per EN 10204 3.1 of the transmitter / seal assembly.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

HTS MALE THREADED SEAL<br />

Table 24. HTS Male Threaded <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

Exp<strong>and</strong>ed<br />

A ANSI/ASME B1.20.1 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers)<br />

D EN 10226-1 (European St<strong>and</strong>ard)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

HTS Male Threaded <strong>Seal</strong><br />

Process Connection Size, Pressure Rating<br />

ANSI/ASME B1.20.1<br />

Exp<strong>and</strong>ed<br />

EN 10226-1<br />

5A (1) 1-11,5 NPT, 8700 psi (600 bar) —<br />

7A (2) 1½-11,5 NPT, 6000 psi (414 bar) —<br />

9A (3)<br />

2-11,5 NPT, 4000 psi (276 bar) —<br />

EA (1) — G1, 455 bar (6600 psi)<br />

GA (2) — G11 /2, BSP, 400 bar (5801 psi)<br />

JA (3)<br />

— G2, BSP, 280 bar (4060 psi)<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

LA00 316L SST (WNr 1.4435) 316L SST<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A HTS 7 A LA 0 0<br />

(1) Consult factory for calibrated spans lower than 300 psi (21 bar).<br />

(2) Consult factory for calibrated spans lower than 100 psi (7 bar).<br />

(3) Consult factory for calibrated spans lower than 50 psi (3,4 bar).<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

73


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

74<br />

Hygienic <strong>Seal</strong>s<br />

SCW HYGIENIC TRI-CLOVER STYLE TRI-CLAMP SEAL<br />

Table 25. SCW Hygienic Tri-Clover Style Tri-Clamp <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Industry St<strong>and</strong>ard<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03) ★<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SCW (1) Tri-Clover Style Tri-Clamp <strong>Seal</strong> ★<br />

Process Connection Size<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

30 (2) 1½-in. ★<br />

50 (3)<br />

2-in. ★<br />

70<br />

Exp<strong>and</strong>ed<br />

3-in. ★<br />

60 2½-in.<br />

90 4-in.<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted Upper Housing<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

LA00<br />

Exp<strong>and</strong>ed<br />

316L SST (WNr 1.4435) 316L SST ★<br />

LB00 Alloy C-276 316L SST<br />

Options (Include with selected model number)<br />

Surface Finish<br />

Exp<strong>and</strong>ed<br />

D 10 �in. (0.25 �m) Ra surface finish<br />

G 15 �in. (0.375 �m) Ra surface finish<br />

H 20 �in. (0.50 �m) Ra surface finish<br />

Non-Hygienic Fill Fluid<br />

Exp<strong>and</strong>ed<br />

P Non-Hygienic fill fluid (does not conform to 3-A St<strong>and</strong>ard 74)<br />

Clamp <strong>and</strong> Gasket Material<br />

Exp<strong>and</strong>ed<br />

2 High-Pressure Ladish Clamp & Nitrile butadiene (NBR) gasket<br />

3 Nitrile butadiene (NBR) gasket<br />

Polishing<br />

Exp<strong>and</strong>ed<br />

6 Electro polishing<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 S SCW 7 0 LA 0 0<br />

(1) Clamp <strong>and</strong> gasket furnished by user. The maximum working pressure is dependent upon the clamp pressure rating.<br />

(2) Consult factory for calibrated spans lower than 15 psi (1034 mbar).<br />

(3) Consult factory for calibrated spans lower than 5 psi (345 mbar).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 26. High Pressure Ladish Clamp Maximum Working Pressure<br />

Process connection size 70 °F (21 °C) 250 °F (121 °C)<br />

1 1 /2-in. 1,500 psi (103 bar) 1,200 psi (83 bar)<br />

2-in. 1,000 psi (69 bar) 800 psi (55 bar)<br />

2 1 /2-in. 1,000 psi (69 bar) 800 psi (55 bar)<br />

3-in. 1,000 psi (69 bar) 800 psi (55 bar)<br />

4-in. 1,000 psi (69 bar) 800 psi (55 bar)<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

75


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

SSW HYGIENIC TANK SPUD SEAL<br />

Table 27. SSW Hygienic Tank Spud <strong>Seal</strong> Ordering Information<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

(3) Requires Option code 6, Electro polishing.<br />

76<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03) ★<br />

Process Connection Style<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

SSW (1) Tank Spud <strong>Seal</strong> ★<br />

Process Connection Size, Pressure Rating<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A0 600 psi (41 bar) ★<br />

Upper Housing<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

A 316L SST ★<br />

Diaphragm <strong>and</strong> Wetted, Extension Material<br />

Diaphragm <strong>and</strong> Wetted Extension<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

AL 316L SST (WNr 1.4435) (2)<br />

316L SST (2) ★<br />

Exp<strong>and</strong>ed<br />

BB Alloy C-276 316L SST ★<br />

Extension Length<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

2 2-in. ★<br />

6 6-in. ★<br />

Options (Include with selected model number)<br />

Surface Finish<br />

Exp<strong>and</strong>ed<br />

G (3) 15 �in. (0.375 �m) diaphragm surface finish<br />

H 20 �in�(0.5 �m) diaphragm surface finish<br />

Diaphragm Thickness<br />

Exp<strong>and</strong>ed<br />

C 0.006-in. (150 �m)<br />

Tank Spud<br />

St<strong>and</strong>ard St<strong>and</strong>ard<br />

1 Tank Spud Included with Shipment ★<br />

Non-Hygienic Fill Fluid<br />

Exp<strong>and</strong>ed<br />

P Non-Hygienic fill fluid (Does not conform to 3-A St<strong>and</strong>ard 74)<br />

Non-Hygienic Fill Fluid<br />

Exp<strong>and</strong>ed<br />

3 Nitrile butadiene (NBR) O-ring instead of St<strong>and</strong>ard Ethylene Propylene O-ring (Conforms to 3-A St<strong>and</strong>ard 74)<br />

4 Fluorocarbon (FMK) ® O-ring, instead of St<strong>and</strong>ard Ethylene Propylene O-ring (Conforms to 3-A St<strong>and</strong>ard 74)<br />

Polishing<br />

Exp<strong>and</strong>ed<br />

6 Electro polishing<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 S SSW A 0 AA L 2<br />

(1) Clamp <strong>and</strong> Ethylene Propylene o-ring (conforms to 3-A st<strong>and</strong>ard 74 <strong>and</strong> USP class VI) supplied.<br />

(2) Diaphragm brazed <strong>and</strong> TIG-welded to extension.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Sanitary Tank Spud Accessories<br />

5.98<br />

(152)<br />

3.70<br />

(94)<br />

0.50<br />

(13)<br />

0.19 (5)<br />

0.09<br />

(2)<br />

Table 28. Sanitary Tank Spud Optional Accessories<br />

Tank Spud <strong>and</strong> Clamp<br />

<strong>Rosemount</strong> 1151 with 1151 Direct Mount Sanitary<br />

Tank Spud with Tank Spud <strong>and</strong> Clamp<br />

Tank Spud Tank Spud Plug<br />

Dimensions are in inches (millimeters)<br />

Model Description Model Description<br />

<strong>1199</strong>-0061- Sanitary Tank Spud (1) <strong>1199</strong>-0552- Sanitary Tank Spud Plug<br />

Code Size Code Size<br />

0001 2 in. 0001 2 in.<br />

0002 6 in. 0002 6 in.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

(1) Welding procedures <strong>and</strong> material certifications are shipped with the tank spud. St<strong>and</strong>ard material is cast equivalent of 316L SST per ASTM- A351 grade<br />

CF3M.<br />

Table 29. Sanitary Tank Spud Spare Parts<br />

Part Number Description<br />

0<strong>1199</strong>-0526-0002 Clamp<br />

C53185-0070-0341 Ethylene Propylene O-ring<br />

A<br />

20° ± 1°<br />

5.22<br />

(133)<br />

37-01<br />

74<br />

R<br />

5.22<br />

(133)<br />

3.93<br />

(100)<br />

3.63<br />

(92)<br />

A<br />

1.10<br />

(28)<br />

20°<br />

77


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

78<br />

STW HYGIENIC THIN WALL TANK SPUD SEAL<br />

Table 30. STW Hygienic Thin Wall Tank Spud <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

STW (1) Thin Wall Tank Spud <strong>Seal</strong><br />

Process Connection Size, Pressure Rating<br />

Exp<strong>and</strong>ed<br />

B0 4-in. Tri-Clamp, 600 psi (41 bar)<br />

Diaphragm <strong>and</strong> Wetted, Extension Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Extension<br />

LA00 316L SST (WNr 1.4435) 316L SST<br />

BB00 Alloy C-276 Alloy C-276<br />

Options (Include with selected model number)<br />

Surface Finish<br />

Exp<strong>and</strong>ed<br />

G (2) 15 �in. (0.375 �m) diaphragm surface finish<br />

H 20 �in�(0.5 �m) diaphragm surface finish<br />

Non-Hygienic Fill Fluid<br />

Exp<strong>and</strong>ed<br />

P Non-Hygienic fill fluid (Does not conform to 3-A St<strong>and</strong>ard 74)<br />

Polishing<br />

Exp<strong>and</strong>ed<br />

6 Electro polishing<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 S STW B 0 LA 0 0<br />

(1) For tank walls up to 3 /16-in. thick. Clamp <strong>and</strong> Ethylene Propylene o-ring supplied.<br />

(2) Requires Option code 6, Electro polishing.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

EES HYGIENIC FLANGED TANK SPUD EXTENDED SEAL<br />

Table 31. EES Hygienic Flanged Tank Spud Extended <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

EES Flanged Tank Spud <strong>Seal</strong><br />

Process Connection Size, Pressure Rating<br />

Exp<strong>and</strong>ed<br />

GG DN 50, PN 40<br />

JG DN 80, PN 40<br />

Diaphragm <strong>and</strong> Wetted, Extension Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Extension<br />

LA 316L SST (WNr 1.4435) 316L SST<br />

LB Alloy C-276 316L SST<br />

Extension Length (1)<br />

Exp<strong>and</strong>ed<br />

10 25 mm (1-in.)<br />

Options (Include with selected model number)<br />

Surface Finish<br />

Exp<strong>and</strong>ed<br />

G (2) 15 µ-in. (0.375 µm) Ra surface finish<br />

H 20 µ-in. (0.50 µm) Ra surface finish<br />

Gasket Material<br />

Exp<strong>and</strong>ed<br />

1 Fluorocarbon (FMK) O-ring, instead of St<strong>and</strong>ard Ethylene Propylene O-ring (Conforms to 3-A St<strong>and</strong>ard 74)<br />

Cold Temperature Application<br />

Exp<strong>and</strong>ed<br />

B Extra Fill For Cold Temperature Application<br />

Polishing<br />

Exp<strong>and</strong>ed<br />

6 Electro polishing<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 S EES J G LA 1 0<br />

(1) Other extension lengths are available upon request.<br />

(2) Requires Option code 6, Electro polishing.<br />

79


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

80<br />

VCS TRI-CLAMP ® IN-LINE SEAL<br />

Table 32. VCS Tri-Clamp In-Line <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

VCS (1) In-Line Tri-Clover Style Tri-Clamp <strong>Seal</strong><br />

Process Connection Size<br />

Exp<strong>and</strong>ed<br />

20 (2) 1-in.<br />

30 (3)<br />

1½-in.<br />

50 2-in.<br />

70 3-in.<br />

90 4-in.<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

LA00 316L SST (WNr 1.4435) 316L SST<br />

Options (Include with selected model number)<br />

Surface Finish<br />

Exp<strong>and</strong>ed<br />

G (4) 15 �-in. (0.375 �m) Ra surface finish<br />

H 20 µ-in. (0.50 µm) Ra surface finish<br />

Non-Hygienic Fill Fluid<br />

Exp<strong>and</strong>ed<br />

P<br />

Polishing<br />

Exp<strong>and</strong>ed<br />

Non-Hygienic fill fluid (does not conform to 3-A St<strong>and</strong>ard 74)<br />

6 Electro polishing<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 S VCS 7 0 LA 0 0<br />

(1) Gasket <strong>and</strong> clamp are furnished by the user. The maximum working pressure is dependent upon the clamp pressure rating.<br />

(2) Consult factory for calibrated spans lower than 15 psi (1034 mbar).<br />

(3) Consult factory for calibrated spans lower than 5 psi (345 mbar).<br />

(4) Requires Option code 6, Electro polishing.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

SVS VARIVENT ® COMPATIBLE HYGIENIC CONNECTION SEAL<br />

Table 33. SVS Varivent ® Compatible Hygienic Connection <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

SVS Tuchenhagen Varivent Compatible <strong>Seal</strong><br />

Process Connection Size<br />

Exp<strong>and</strong>ed<br />

V0 (1) Varivent ® Type N DN 40-162<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

LA00 316L SST (WNr 1.4435) 316L SST<br />

Options (Include with selected model number)<br />

Non-Hygienic Fill Fluid<br />

Exp<strong>and</strong>ed<br />

P Non-Hygienic fill fluid (does not conform to 3-A St<strong>and</strong>ard 74)<br />

Cold Temperature Application<br />

Exp<strong>and</strong>ed<br />

B Extra Fill For Cold Temperature Application<br />

Polishing<br />

Exp<strong>and</strong>ed<br />

6 Electro polishing<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 S SVS V 0 LA 0 0<br />

(1) Consult factory for calibrated spans lower than 15 psi (1034 mbar).<br />

81


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

82<br />

SHP Hygienic Cherry-Burrell “I” LINE SEAL<br />

Table 34. SHP Hygienic Cherry-Burrell “I” Line <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

SHP (1) Cherry-Burrell “I” Line Style <strong>Seal</strong><br />

Process Connection Size<br />

Exp<strong>and</strong>ed<br />

50 (2) 2-in.<br />

70 3-in.<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

AA00 316L SST (WNr 1.4435) 316L SST<br />

Options (Include with selected model number)<br />

Non-Hygienic Fill Fluid<br />

Exp<strong>and</strong>ed<br />

P Non-Hygienic fill fluid (does not conform to 3-A St<strong>and</strong>ard 74)<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 S SHP 7 0 AA 0 0<br />

(1) Clamp <strong>and</strong> gasket furnished by user. Maximum working pressure is the lesser of either clamp pressure rating or 500 psi.<br />

(2) Consult factory for calibrated spans lower than 5 psi (345 mbar).<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

SLS DAIRY PROCESS CONNECTION - FEMALE THREAD SEAL PER DIN 11851<br />

Table 35. SLS Hygienic Dairy Process Connection Female Thread <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

S Hygienic <strong>Seal</strong> (Conforms to 3-A St<strong>and</strong>ard 74-03)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

SLS Dairy Process Connection - Female Thread<br />

Process Connection Size, Pressure Rating, Material<br />

Exp<strong>and</strong>ed<br />

F0 (1)<br />

DIN 11851 with coupling nut DN 40, PN 40, 304 SST<br />

G0 (2)<br />

DIN 11851 with coupling nut DN 50, PN 25, 304 SST<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

LA00 316L SST (WNr 1.4435) 316L SST<br />

Options (Include with selected model number)<br />

Polishing<br />

Exp<strong>and</strong>ed<br />

6 Electro polishing<br />

Typical Model Number: <strong>1199</strong> W HC 1 0 S SLS J 0 LA 0 0<br />

(1) Consult factory for calibrated spans lower than 15 psi (1034 mbar).<br />

(2) Consult factory for calibrated spans lower than 5 psi (345 mbar).<br />

83


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

WSP SADDLE SEAL<br />

Specialty <strong>Seal</strong>s<br />

Table 36. WSP Saddle <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

N Non-Industry St<strong>and</strong>ard<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

WSP Saddle <strong>Seal</strong><br />

Process Connection Size<br />

Exp<strong>and</strong>ed<br />

G 2-in. Pipe size<br />

7 3-in. Pipe size<br />

9 4-in. or larger Pipe size<br />

Pressure Rating<br />

Exp<strong>and</strong>ed<br />

1 1500 psig at 100 °F (103 bar at 38 °C); eight bolt holes<br />

0 1250 psig at 100 °F (86 bar at 38 °C); six bolt holes<br />

Diaphragm, Upper Housing Material<br />

Diaphragm<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

LA 316L SST 316L SST<br />

LB Alloy C-276 316L SST<br />

LC Tantalum 316L SST<br />

Lower Housing Material (1)(2)<br />

Exp<strong>and</strong>ed<br />

00 None<br />

L5 316L SST<br />

B5 Alloy C-276<br />

D5 Plated Carbon Steel<br />

Options (Include with selected model number)<br />

Gasket Material<br />

Exp<strong>and</strong>ed<br />

J PTFE gasket<br />

N Grafoil ® gasket<br />

Code Conformance<br />

Exp<strong>and</strong>ed<br />

T (3) Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

V (4) PTFE Coated Diaphragm for nonstick purposes (316L SST <strong>and</strong> Alloy C-276 diaphragms only)<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 N WSP 7 1 LA L N<br />

(1) St<strong>and</strong>ard pipe schedule 40/40S, for other pipe schedules consult the factory.<br />

(2) Supplied with C4401 Aramid fiber gasket.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(3) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(4) Not available with transmitter option code Q8, for Material Traceability per EN10204 3.1 of the transmitter / seal assembly. Only available on 316LSS <strong>and</strong><br />

Alloy C-276.<br />

84


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

UCP MALE THREADED PIPE MOUNT SEALS AND PMW PAPER MILL<br />

SLEEVE SEALS<br />

Table 37. UCP <strong>and</strong> PMW Threaded Pipe Mount <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Industry St<strong>and</strong>ard<br />

Exp<strong>and</strong>ed<br />

N Non-Industry St<strong>and</strong>ard<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

UCP Male Threaded Pipe Mount <strong>Seal</strong><br />

PMW Paper Mill Sleeve<br />

Process Connection Size, Pressure Rating<br />

Exp<strong>and</strong>ed<br />

30 (1) 11 /2-in., Threaded Knurled Nut, 600 psi at 100 °F (41 bar at 38 °C) (UCP only)<br />

50 (2) 1-in., Cap Screw Retainer, 300 psi at 100 °F (21 bar at 38 °C) (PMW only)<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

AA 316L SST 316L SST<br />

BB Alloy C-276 Alloy C-276<br />

Lower Housing Material<br />

Exp<strong>and</strong>ed<br />

00 None<br />

A0 316L SST<br />

B0 Alloy C-276<br />

Options (Include with selected model number)<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

V (3) PTFE coated diaphragm for nonstick purposes only<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 N UCP 3 0 AA A 0<br />

(1) Only available with UCP process connection size. Consult factory for calibrated spans lower than 50 psi (3,4 bar).<br />

(2) Only available with PMW process connection size. Consult factory for calibrated spans lower than 100 psi (6,9 bar).<br />

(3) Not available with transmitter option code Q8, for Material Traceability per EN10204 3.1 of the transmitter / seal assembly.<br />

85


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

86<br />

CTW CHEMICAL TEE SEAL<br />

Table 38. CTW Chemical Tee <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

N Non-Industry St<strong>and</strong>ard<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

CTW Chemical Tee <strong>Seal</strong><br />

Maximum Working Pressure (Flange Rating)<br />

Exp<strong>and</strong>ed<br />

20 300 psi (21 bar)<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

AA 316L SST 316L SST<br />

BB Alloy C-276 Alloy C-276<br />

Lower Housing<br />

Exp<strong>and</strong>ed<br />

00 None<br />

Options (Include with selected model number)<br />

Code Conformance<br />

Exp<strong>and</strong>ed<br />

T (1) Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103<br />

Diaphragm Coating<br />

Exp<strong>and</strong>ed<br />

V (2) PTFE coated diaphragm for nonstick purposes only<br />

Typical Model Number: <strong>1199</strong> W NC 1 0 N CTW 2 0 AA 0 0<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.<br />

(2) Not available with transmitter option code Q8, for Material Traceability per EN10204 3.1 of the transmitter / seal assembly.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

TFS WAFER STYLE IN-LINE SEAL<br />

Table 39. TFS Wafer Style In-Line <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code<br />

Exp<strong>and</strong>ed<br />

Industry St<strong>and</strong>ard<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers)<br />

D EN 1092-1 (European St<strong>and</strong>ard)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

TFS Wafer Style In-Line <strong>Seal</strong><br />

Process Connection Size<br />

ANSI/ASME B16.5<br />

Exp<strong>and</strong>ed<br />

EN 1092-1<br />

G 2-in. DN 50<br />

7 3-in. —<br />

J — DN 80<br />

9 4-in. —<br />

2 (1)<br />

1-in. —<br />

4 (2) 1½-in. —<br />

D (1) — DN 25<br />

F (2)<br />

— DN 40<br />

K — DN 100<br />

Pressure Rating<br />

Exp<strong>and</strong>ed<br />

0 <strong>Seal</strong> MWP based on customer supplied flange<br />

Diaphragm <strong>and</strong> Wetted, Upper Housing Material<br />

Diaphragm <strong>and</strong> Wetted<br />

Exp<strong>and</strong>ed<br />

Upper Housing<br />

LA 316L SST 316L SST<br />

LB Alloy C-276 316L SST<br />

Housing Body Length<br />

Exp<strong>and</strong>ed<br />

00 3.54-in. (90 mm)<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A TFS 7 0 LA 0 0<br />

(1) Consult factory for calibrated spans lower than 15 psi (1034 mbar).<br />

(2) Consult factory for calibrated spans lower than 5 psi (345 mbar).<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

87


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

88<br />

WFW FLOW-THRU FLANGED SEAL<br />

Table 40. WFW Flow-Thru Flanged <strong>Seal</strong> Ordering Information<br />

This seal is part of the Exp<strong>and</strong>ed offering <strong>and</strong> is subject to additional delivery lead time.<br />

Code Industry St<strong>and</strong>ard<br />

Exp<strong>and</strong>ed<br />

A ANSI/ASME B16.5 (American National St<strong>and</strong>ards Institute/American Society of Mechanical Engineers)<br />

Process Connection Style<br />

Exp<strong>and</strong>ed<br />

WFW (1) Flow-Thru Flanged <strong>Seal</strong><br />

Process Connection Size (2)<br />

Exp<strong>and</strong>ed<br />

G 2-in.<br />

7 3-in.<br />

2 1-in.<br />

Flange Rating (2)<br />

Exp<strong>and</strong>ed<br />

1 Class 150 (2)<br />

Diaphragm, Upper Housing Material<br />

Diaphragm Upper Housing (2)<br />

Exp<strong>and</strong>ed<br />

LA 316L SST 316L SST<br />

Lower Housing Material (1)<br />

Exp<strong>and</strong>ed<br />

L 316L SST<br />

Pipe Schedule (2)<br />

Exp<strong>and</strong>ed<br />

N 40/40S<br />

Options (Include with selected model number)<br />

Gasket Material<br />

Exp<strong>and</strong>ed<br />

J PTFE O-ring<br />

K Barium Sulfate filled PTFE gasket<br />

N Grafoil ® gasket<br />

R Ethylene Propylene gasket<br />

Bolt Material<br />

Exp<strong>and</strong>ed<br />

3 304 SST bolts<br />

Code Conformance<br />

Exp<strong>and</strong>ed<br />

T (3) Wetted Material Compliance per NACE MR 0175/ISO 15156, MR 0103<br />

Cold Temperature Application<br />

Exp<strong>and</strong>ed<br />

B Extra Fill For Cold Temperature Application<br />

Typical Model Number: <strong>1199</strong> W DC 1 0 A WFW 7 1 LA L N<br />

(1) Supplied with C4401 Aramid fiber gasket.<br />

(2) Consult factory for special process connection sizes, flange pressure ratings, diaphragm/lower housing materials, <strong>and</strong> pipe schedules.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(3) Materials of Construction comply with metallurgical requirements highlighted within NACE MR 0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest st<strong>and</strong>ard for details. Selected materials also conform to NACE MR 0103 for sour refining<br />

environments.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

LIQUID LEVEL TRANSMITTER<br />

SPECIFICATIONS<br />

Performance Specifications<br />

Specifications<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

For zero-based spans, reference conditions, silicone oil fill, glass-filled PTFE O-rings, SST materials, Coplanar flange (3051SMV, 3051S_C) or<br />

1 /2-in.- 14 NPT (3051S_T) process connections, digital trim values set to equal range points.<br />

Conformance to Specification (±3� (Sigma))<br />

Technology leadership, advanced manufacturing techniques, <strong>and</strong> statistical process control ensure measurement specification conformance to<br />

±3��or better.<br />

Reference Accuracy (1)<br />

Stated reference accuracy equations include terminal based linearity, hysteresis, <strong>and</strong> repeatability, but does not include analog output<br />

reference accuracy of ±0.005% of span.<br />

For FOUNDATION fieldbus <strong>and</strong> wireless devices, use calibrated range in place of span.<br />

3051SAL_C ±0.065% of span;<br />

For spans less than 10:1,<br />

3051L<br />

2051L<br />

�<br />

0.015 + 0.005<br />

�URL ------------- � % of span<br />

�span� All Ranges ±0.075% of span<br />

For spans less than 10:1, accuracy =<br />

�<br />

0.025 + 0.005<br />

� URL<br />

-------------- � % of Span<br />

�Span� Ranges 2-4 ±0.075% of span<br />

For spans less than 10:1, accuracy =<br />

�<br />

0.025 + 0.005<br />

� URL<br />

-------------- � % of Span<br />

�Span� (1) Stated reference accuracy equations include terminal based linearity, hysteresis, <strong>and</strong> repeatability, but does not include analog only reference accuracy of<br />

±0.005% of span.<br />

<strong>DP</strong> Reference Accuracy of 3051S ERS System (1)<br />

Two Coplanar Gage Sensors (3051SAM_ _G)<br />

Ultra Classic<br />

Ranges 2-4 ±0.035% of <strong>DP</strong> span ±0.078% of <strong>DP</strong> span<br />

Range 5 ±0.071% of <strong>DP</strong> span ±0.092% of <strong>DP</strong> span<br />

Two Coplanar (3051SAM_ _A)<br />

Ultra Classic<br />

Ranges 1-4 ±0.035% of <strong>DP</strong> span ±0.078% of <strong>DP</strong> span<br />

Two In-Line Gage Sensors (3051SAM_ _T)<br />

Two In-Line Absolute Sensors (3051SAM_ _E)<br />

Ultra Classic<br />

Ranges 1-4 ±0.035% of <strong>DP</strong> span ±0.078% of <strong>DP</strong> span<br />

Two Liquid <strong>Level</strong> Sensors (3051SAL)<br />

Ultra Classic<br />

Ranges 1-5 ±0.092% of <strong>DP</strong> span ±0.092% of <strong>DP</strong> span<br />

(1) <strong>DP</strong> Accuracy specifications for the 3051S ERS System assume that the configuration contains two sensors with identical ranges that are<br />

calibrated 0 – URL, <strong>and</strong> that the <strong>DP</strong> Span = 10% of each sensor’s URL.<br />

89


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Warranty (1)<br />

Models (1) Ultra Classic<br />

3051SAM <strong>and</strong> 3051SAL 12-year limited warranty (2) 1-year limited warranty (3)<br />

90<br />

(1) Warranty details can be found in Emerson Process Management Terms <strong>and</strong> Conditions of Sale, Document 63445, Rev G (10/06).<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(2) <strong>Rosemount</strong> Ultra <strong>and</strong> Ultra for Flow transmitter have a limited warranty of twelve (12) years from date of shipment. All other provisions of Emerson Process<br />

Management st<strong>and</strong>ard limited warranty remains the same.<br />

(3) Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by seller, whichever period<br />

expires first.<br />

Dynamic Performance<br />

<strong>Rosemount</strong> <strong>Level</strong> <strong>Transmitters</strong> - 3051SAL_C, 3051L, <strong>and</strong> 2051L models - have an 4 - 20 mA HART (1 - 5 Vdc HART Low Power) update rate<br />

of 22 updates per second. Electronic Remote Sensor <strong>Systems</strong> - 3051SAM, 3051SAL_P, <strong>and</strong> 3051SAL_S models - have an 4 - 20 mA HART (1<br />

- 5 Vdc HART Low Power) update rate of 11 updates per second. See page 94 for WirelessHART update rates.<br />

For total response time see Instrument Toolkit ® .<br />

Ambient Temperature Effect<br />

See Instrument Toolkit.<br />

Mounting Position Effects<br />

With liquid level remote mount seal in vertical plane, zero shift of up to ±1 inH2O (2,49 mbar); with remote mount seal in horizontal plane, zero<br />

shift of up to ±5 inH2O (12,45 mbar) plus extension length on extended units; all zero shifts can be zeroed; no span effect.<br />

Vibration Effect<br />

3051SAM<br />

3051SAL<br />

3051L<br />

2051L<br />

Power Supply Effect<br />

Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz<br />

0.21mm displacement peak amplitude / 60-2000 Hz 3g).<br />

For Housing Style codes 1J, 1K, 1L, 2J, <strong>and</strong> 2M:<br />

Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field with general application or pipeline with low<br />

vibration level (10-60 Hz 0.15mm displacement peak amplitude / 60-500 Hz 2g).<br />

Measurement effect due to vibrations is negligible except at resonance frequencies. When at resonance frequencies,<br />

vibration effect is less than ±0.1% of URL per g when tested between 15 <strong>and</strong> 2000 Hz in any axis relative to pipe-mounted<br />

process conditions.<br />

Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz<br />

0.21mm displacement peak amplitude / 60-2000 Hz 3g).<br />

Less than ±0.005% of calibrated span per volt.<br />

Electromagnetic Compatibility (EMC)<br />

Meets all relevant requirements of EN 61326 <strong>and</strong> NAMUR NE-21. (1)<br />

(1) NAMUR NE-21 does not apply to wireless output code X.<br />

Transient Protection (Option T1)<br />

3051SAM<br />

3051SAL<br />

3051L<br />

2051L<br />

Meets IEEE C62.41.2-2002, Location Category B<br />

6 kV crest (0.5 �s - 100 kHz)<br />

3 kA crest (8 × 20 microseconds)<br />

6 kV crest (1.2 × 50 microseconds)<br />

Meets IEEE C62.41, Category B<br />

6 kV crest (0.5 �s - 100 kHz)<br />

3 kV crest (8 × 20 microseconds)<br />

6 kV crest (1.2 × 50 microseconds)<br />

Meets IEEE C62.41, Category Location B<br />

6 kV crest (0.5 �s - 100 kHz)<br />

3 kV crest (8 × 20 microseconds)<br />

6 kV crest (1.2 × 50 microseconds)


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Functional Specifications<br />

Range <strong>and</strong> Sensor Limits<br />

Table 41. 3051SAM_ _G, 3051SAL_ _D, 3051SAL_ _G Range <strong>and</strong> Sensor Limits<br />

Minimum Span Range Limits<br />

Range<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Ultra Classic Upper (URL)<br />

Lower (LRL)<br />

3051SAL_G (1)(2) 3051SAL_D (1)<br />

2 1.3 inH2O (3,11 mbar) 2.5 inH2O (6,23 mbar) 250.0 inH2O (0,62 bar) -250.0 inH2O (-0,62 bar) -250.0 inH2O (-0,62 bar)<br />

3 5.0 inH2O (12,4 mbar) 10.0 inH2O (24,9 mbar) 1000.0 inH2O (2,49 bar) -393.0 inH2O (-979 mbar) -1000.0 inH2O (-2,49 bar)<br />

4 1.5 psi (103,4 mbar) 3.0 psi (206,8 mbar) 300.0 psi (20,7 bar) -14.2 psig (-979 mbar) -300.0 psi (-20,7 bar)<br />

5 10.0 psi (689,5 mbar) 20.0 psi (1,38 bar) 2000.0 psi (137,9 bar) -14.2 psig (-979 mbar) - 2000.0 psi (-137,9 bar)<br />

(1) When specifying a 3051SAL Ultra, use Classic minimum span.<br />

(2) Assumes atmospheric pressure of 14.7 psig (1 bar).<br />

Table 42. 3051SAM_ _A, 3051SAL_ _A Range <strong>and</strong> Sensor Limits (1)<br />

Minimum Span Range <strong>and</strong> Sensor Limits<br />

Ultra Classic<br />

Upper (URL) Lower (LRL)<br />

1 0.3 psia (20,7 mbar) 0.3 psia (20,7 mbar) 30 psia (2,07 bar) 0 psia (0 bar)<br />

2 0.75 psia (51,7 mbar) 1.5 psia (0,103 bar) 150 psia (10,34 bar) 0 psia (0 bar)<br />

3 4 psia (275,8 mbar) 8 psia (0,55 bar) 800 psia (55,16 bar) 0 psia (0 bar)<br />

4 20 psia (1,38 bar) 40 psia (2,76 bar) 4000 psia (275,8 bar) 0 psia (0 bar)<br />

Range<br />

(1) When specifying a 3051SAL Ultra, use Classic minimum span.<br />

Table 43. 3051SAM_ _T, 3051SAM_ _E, 3051SAL_ _T, 3051SAL_ _E Range <strong>and</strong> Sensor Limits<br />

Minimum Span Range <strong>and</strong> Sensor Limits<br />

Ultra Classic Upper (URL) Lower (LRL) (Abs.) Lower (1) (LRL) (Gage)<br />

1 0.3 psi (20,7 mbar) 0.3 psi (20,7 mbar) 30 psi (2,07 bar) 0 psia (0 bar) -14.7 psig (-1,01 bar)<br />

2 0.75 psi (51,7 bar) 1.5 psi (0,103 bar) 150 psi (10,34 bar) 0 psia (0 bar) -14.7 psig (-1,01 bar)<br />

3 4 psi (275,8 mbar) 8 psi (0,55 bar) 800 psi (55,16 bar) 0 psia (0 bar) -14.7 psig (-1,01 bar)<br />

4 20 psi (1,38 bar) 40 psi (2,76 bar) 4000 psi (175,8 bar) 0 psia (0 bar) -14.7 psig (-1,01 bar)<br />

5 1000 psi (68,9 bar) 2000 psi (137,9 bar) 10000 psi (689,5 bar) 0 psia (0 bar) -14.7 psig (-1,01 bar)<br />

Range<br />

(1) Assumes atmospheric pressure of 14.7 psig (1 bar).<br />

Table 44. 3051L Range <strong>and</strong> Sensor Limits<br />

Upper<br />

Range <strong>and</strong> Sensor Limits<br />

Lower (LRL)<br />

Minimum Span<br />

(URL)<br />

3051L Differential 3051L Gage<br />

2 2.5 inH2O (6,2 mbar) 250 inH2O (0,62 bar) –250 inH2O (–0,62 bar) –250 inH2O (–0,62 bar)<br />

3 10 inH2O (24,9 mbar) 1000 inH2O (2,49 bar) –1000 inH2O (–2,49 bar) 0.5 psia (34,5 mbar abs)<br />

4 3 psi (0,20 bar) 300 psi (20,6 bar) –300 psi (–20,6 bar) 0.5 psia (34,5 mbar abs)<br />

5 20 psi (1,38 bar) 2000 psi (137,9 bar) NA NA<br />

Range<br />

Table 45. 2051L Range <strong>and</strong> Sensor Limits<br />

Range<br />

Range <strong>and</strong> Sensor Limits<br />

Lower (LRL)<br />

Minimum Span<br />

Upper (URL)<br />

2051L Differential 2051L Gage (1)<br />

2 2.5 inH2O (6,2 mbar) 250 inH2O (0,62 bar) –250 inH2O (–0,62 bar) –250 inH2O (–0,62 bar)<br />

3 10 inH2O (24,9 mbar) 1000 inH2O (2,49 bar) –1000 inH2O (–2,49 bar) –393 inH2O (–979 mbar)<br />

4 3 psi (0,207 bar) 300 psi (20,6 bar) –300 psi (–20,7 bar) –14.2 psig (–979 mbar)<br />

(1) Assumes atmospheric pressure of 14.7 psig.<br />

91


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Service<br />

Liquid, gas, <strong>and</strong> vapor applications<br />

Protocols<br />

4–20 mA (Output Code A)<br />

Output<br />

Two-wire 4–20 mA, user-selectable for linear or square root<br />

output. Digital process variable superimposed on 4–20 mA signal,<br />

available to any host that conforms to the HART protocol.<br />

Power Supply<br />

External power supply required. St<strong>and</strong>ard transmitter (4–20 mA)<br />

operates on 10.5 to 42.4 Vdc with no load. The 3051S ERS<br />

System operates on 16 - 42.4 Vdc with no load.<br />

Load Limitations<br />

Maximum loop resistance is determined by the voltage level of the<br />

external power supplied as described by:<br />

FOUNDATION fieldbus (output code F)<br />

Power Supply<br />

External power supply required; transmitters operate on 9.0 to<br />

32.0 Vdc transmitter terminal voltage.<br />

Current Draw<br />

17.5 mA for all configurations (including LCD display option)<br />

Indication<br />

Optional two line LCD Display<br />

92<br />

St<strong>and</strong>ard HART Transmitter<br />

Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 10.5)<br />

Load (Ohms)<br />

1387<br />

1000<br />

500<br />

0<br />

Operating<br />

Region<br />

10.5 20 30<br />

Voltage (Vdc)<br />

42.4<br />

The Field Communicator requires a minimum<br />

loop resistance of 250� for communication.<br />

3051S ERS System<br />

If supply voltage ≤ 16.74 Vdc:<br />

Maximum Loop Resistance = 277 * (Power Supply Voltage – 16.0)<br />

If supply voltage > 16.74 Vdc:<br />

Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 12.0)<br />

Load (Ohms)<br />

1322<br />

Operating<br />

206<br />

Region<br />

0<br />

16 16.74<br />

42.4<br />

Voltage (Vdc)<br />

The Field Communicator requires a minimum<br />

loop resistance of 250� for communication.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

FOUNDATION fieldbus Function Block Execution Times<br />

Block Execution Time (Milliseconds)<br />

3051SAL_C 3051L 2051L<br />

Resource - - -<br />

Transducer - - -<br />

LCD Block - - -<br />

Analog Input 1, 2 20 30 35<br />

PID 35 (1) 45 45<br />

Input Selector 20 30 30<br />

Arithmetic 20 35 35<br />

Signal Characterizer 20 40 40<br />

Integrator 20 35 35<br />

Output Splitter 20 N/A N/A<br />

Control Selector 20 N/A N/A<br />

(1) PID with Auto-tune.<br />

FOUNDATION fieldbus Parameters<br />

Schedule Entries 7 (max.)<br />

Links 20 (max.)<br />

Virtual Communications Relationships (VCR) 12 (max.)<br />

St<strong>and</strong>ard Function Blocks<br />

Resource Block<br />

Contains hardware, electronics, <strong>and</strong> diagnostic information.<br />

Transducer Block<br />

Contains actual sensor measurement data including the sensor<br />

diagnostics <strong>and</strong> the ability to trim the pressure sensor or recall<br />

factory defaults.<br />

LCD Block<br />

Configures the local display.<br />

2 Analog Input Blocks<br />

Processes the measurements for input into other function<br />

blocks. The output value is in engineering units or custom <strong>and</strong><br />

contains a status indicating measurement quality.<br />

PID Block<br />

Contains all logic to perform PID control in the field including<br />

cascade <strong>and</strong> feedforward.<br />

Backup Link Active Scheduler (LAS)<br />

The transmitter can function as a Link Active Scheduler if the<br />

current link master device fails or is removed from the segment.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Advanced Control Function Block Suite (Option Code A01)<br />

Input Selector Block<br />

Selects between inputs <strong>and</strong> generates an output using specific<br />

selection strategies such as minimum, maximum, midpoint,<br />

average, or first “good.”<br />

Arithmetic Block<br />

Provides pre-defined application-based equations including flow<br />

with partial density compensation, electronic remote seals,<br />

hydrostatic tank gauging, ratio control, <strong>and</strong> others.<br />

Signal Characterizer Block<br />

Characterizes or approximates any function that defines an<br />

input/output relationship by configuring up to twenty X, Y<br />

coordinates. The block interpolates an output value for a given<br />

input value using the curve defined by the configured<br />

coordinates.<br />

Integrator Block<br />

Compares the integrated or accumulated value from one or two<br />

variables to pre-trip <strong>and</strong> trip limits <strong>and</strong> generates discrete output<br />

signals when the limits are reached. This block is useful for<br />

calculating total flow, total mass, or volume over time.<br />

FOUNDATION fieldbus Diagnostics Suite (Option Code D01)<br />

The FOUNDATION fieldbus Diagnostics provide Abnormal<br />

Situation Prevention (ASP) indication. The integral statistical<br />

process monitoring (SPM) technology calculates the mean <strong>and</strong><br />

st<strong>and</strong>ard deviation of the process variable 22 times per second.<br />

The 3051S_L <strong>and</strong> 3051L use these values <strong>and</strong> highly flexible<br />

configuration options for customization to detect many<br />

user-defined or application specific abnormal situations (e.g.<br />

detecting plugged impulse lines <strong>and</strong> fluid composition change).<br />

Profibus PA (Output Code W)<br />

Profile Version<br />

3.02<br />

Power Supply<br />

External power supply required; transmitters operate on 9.0 to<br />

32.0 Vdc transmitter terminal voltage.<br />

Current Draw<br />

17.5 mA for all configurations (including LCD display option)<br />

Output Update Rate<br />

Four times per second<br />

St<strong>and</strong>ard Function Blocks<br />

Analog Input (AI Block)<br />

The AI function block processes the measurements <strong>and</strong> makes<br />

them available to the host device. The output value from the AI<br />

block is in engineering units <strong>and</strong> contains a status indicating the<br />

quality of the measurement.<br />

Physical Block<br />

The physical block defines the physical resources of the device<br />

including type of memory, hardware, electronics, <strong>and</strong> diagnostic<br />

information.<br />

Transducer Block<br />

Contains actual sensor measurement data including the sensor<br />

diagnostics <strong>and</strong> the ability to trim the pressure sensor or recall<br />

factory defaults.<br />

Indication<br />

Optional two line LCD display<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Local Operator Interface<br />

Optional external configuration buttons<br />

3051SAL_C Wireless Self-Organizing Networks<br />

Output<br />

IEC 62591 (WirelessHART), 2.4 GHz DSSS<br />

Radio Frequency Power Output from Antenna<br />

External Antenna (WK option): Maximum of 10 mW (10 dBm)<br />

EIRP<br />

Extended Range, External Antenna (WM option): Maximum of<br />

18 mW (12.5 dBm) EIRP<br />

High-Gain, Remote Antenna (WN option): Maximum of 40 mW<br />

(16 dBm) EIRP<br />

Local Display<br />

The optional seven-digit LCD can display primary variable in<br />

engineering units, percent of range, sensor module<br />

temperature, <strong>and</strong> electronics temperature. Display updates at<br />

update rate up to once per minute. The display updates based<br />

on the wireless update rate.<br />

Update Rate<br />

User selectable 1 sec. to 60 min.<br />

Power Module<br />

Field replaceable, keyed connection eliminates the risk of<br />

incorrect installation, Intrinsically Safe Lithium-thionyl chloride<br />

Power Module with polybutadine terephthalate (PBT)<br />

enclosure. Ten-year life at one minute update rate. (1)<br />

(1) Reference conditions are 70 °F (21 °C), <strong>and</strong> routing data for three<br />

additional network devices.<br />

NOTE: Continuous exposure to ambient temperature limits of<br />

-40 °F or 185 °F (-40 °C or 85 °C) may reduce specified life by less<br />

than 20 percent.<br />

Overpressure Limits<br />

Limit is 0 psia to the flange rating or sensor rating, whichever is<br />

lower.<br />

Table 46. 3051L <strong>and</strong> <strong>Level</strong> Flange Rating Limits<br />

St<strong>and</strong>ard Type CS Rating SST Rating<br />

ANSI/ASME Class 150 285 psig 275 psig<br />

ANSI/ASME Class 300 740 psig 720 psig<br />

ANSI/ASME Class 600 1480 psig 1440 psig<br />

At 100 °F (38 °C), the rating decreases<br />

with increasing temperature, per ANSI/ASME B16.5.<br />

DIN PN 10–40 40 bar 40 bar<br />

DIN PN 10/16 16 bar 16 bar<br />

DIN PN 25/40 40 bar 40 bar<br />

At 122 °F (50 °C), the rating decreases with increasing<br />

temperature per EN 1092-1 Annex F.<br />

93


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Temperature Limits<br />

Ambient<br />

-40 to 185 °F (-40 to 85 °C)<br />

With LCD display (1) : -40 to 175 °F (-40 to 80 °C)<br />

With option code P0: -20 to 185 °F (-29 to 85 °C)<br />

Storage<br />

94<br />

(1) LCD display may not be readable <strong>and</strong> LCD updates will be slower<br />

at temperatures below -4 °F (-20 °C).<br />

-50 to 185 °F (-46 to 85 °C)<br />

With LCD display: -40 to 185 °F (-40 to 85 °C)<br />

With Wireless Output: -40 to 185 °F (-40 to 85 °C)<br />

Table 48. Fill Fluid Specifications<br />

For more information on Fill Fluids please see technical note <strong>Rosemount</strong> <strong>1199</strong> Fill Fluid Specifications 00840-2100-4016.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 47. ERS Process Temperature Limits (Gage / Absolute Sensor)<br />

Coplanar Gage / Absolute Sensor In-Line Gage Sensor / Absolute Sensor<br />

Configuration<br />

(3051SAM_ _G, 3051SAM_ _A)<br />

(3051SAM_ _T, 3051SAM_ _E)<br />

Silicone Fill Fluid (1)<br />

- -40 to 250 °F (-40 to 121 °C) (3)<br />

with Coplanar Flange (1) -40 to 250 °F (-40 to 121 °C) (3) -<br />

with Traditional Flange (2)<br />

-40 to 300 °F (-40 to 149 °C) (3) -<br />

with <strong>Level</strong> Flange (2) -40 to 300 °F (-40 to 149 °C) (3)<br />

-<br />

with 305 Integral Manifold (1) -40 to 300 °F (-40 to 149 °C) (3) -<br />

Inert Fill Fluid (1)(4)<br />

-40 to 185 °F (-40 to 85 °C) (5)<br />

-22 to 250 °F (-30 to 121 °C) (3)<br />

(1) Process temperatures above 185 °F (85 °C) require de-rating the ambient limits by a 1.5:1 ratio. For example, for process temperature of 195 °F (91 °C),<br />

new ambient temperature limit is equal to 170 °F (77 °C). This can be determined as follows: (195 °F - 185 °F) x 1.5 = 15 °F, 185 °F - 15 °F = 170 °F.<br />

(2) Process temperatures above 185 °F (85 °C) require de-rating the ambient limits by a 1:1 ratio.<br />

(3) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures below 0.5 psia.<br />

(4) Not available with 3051SAM_ _A.<br />

(5) 160 °F (71 °C) limit in vacuum service.<br />

<strong>Seal</strong> Fill Fluid Specific<br />

Gravity<br />

at 77 °F<br />

(25 °C)<br />

Coeff. Of<br />

Therm. Exp.<br />

(cc/cc/°C)<br />

Viscosity at<br />

77 °F (25 °C)<br />

(Centistokes)<br />

Temperature Limits (1)<br />

No Extension 2-in. (50mm)<br />

Extension<br />

A Syltherm XLT 0.85 0.00<strong>1199</strong> 1.6 -102 to 293 °F<br />

(-75 to 145 °C)<br />

C Silicone 704 1.07 0.00095 44 32 to 401 °F<br />

(0 to 205 °C) (2)<br />

D Silicone 200 0.93 0.00108 9.5 -49 to 401 °F<br />

(-45 to 205 °C)<br />

H Inert<br />

(Halocarbon)<br />

G (3)(4) Glycerin <strong>and</strong><br />

Water<br />

N (4)<br />

1.85 0.000864 6.5 -49 to 320 °F<br />

(-45 to 160 °C)<br />

1.13 0.00034 12.5 5 to 203 °F<br />

(-15 to 95 °C)<br />

Neobee M–20 0.92 0.001008 9.8 5 to 401 °F (2)<br />

(-15 to 205 °C)<br />

P (3)(4) Proylene 1.02 0.00034 2.8 5 to 203 °F<br />

Glycol <strong>and</strong><br />

Water<br />

(-15 to 95 °C)<br />

(1) Temperature limits are reduced in vacuum service <strong>and</strong> may be limited by seal selection.<br />

-102 to 293 °F<br />

(-75 to 145 °C)<br />

32 to 464 °F<br />

(0 to 240 °C) (2)<br />

-49 to 401 °F<br />

(-45 to 205 °C)<br />

-49 to 320 °F<br />

(-45 to 160 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

5 to 437 °F<br />

(-15 to 225 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

4-in. (100mm)<br />

Extension<br />

102 to 293 °F<br />

(-75 to 145 °C)<br />

32 to 500 °F<br />

(0 to 260 °C) (2)<br />

-49 to 401 °F<br />

(-45 to 205 °C)<br />

-49 to 320 °F<br />

(-45 to 160 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

5 to 437 °F<br />

(-15 to 225 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

Thermal<br />

Optimizer<br />

102 to 293 °F<br />

(-75 to 145 °C)<br />

32 to 599 °F<br />

(0 to 315 °C)<br />

-49 to 401 °F<br />

(-45 to 205 °C)<br />

-49 to 320 °F<br />

(-45 to 160 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

5 to 437 °F<br />

(-15 to 225 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

Temperature<br />

Limits < 1<br />

bar-a<br />

Capillary Capillary<br />

102 to 293 °F<br />

(-75 to 145 °C)<br />

32 to 599 °F<br />

(0 to 315 °C)<br />

-49 to 401 °F<br />

(-45 to 205 °C)<br />

-49 to 320 °F<br />

(-45 to 160 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

5 to 437 °F<br />

(-15 to 225 °C)<br />

5 to 203 °F<br />

(-15 to 95 °C)<br />

(2) Maximum process temperature is limited by heat transfer to the transmitter electronics <strong>and</strong> must be further derated if ambient temperatures exceed 70°F (21°C).<br />

(3) Not suitable for vacuum applications.<br />

(4) This is a food grade fill fluid.<br />

—<br />

32 to 392 °F<br />

(0 to 200 °C)<br />

-49 to 212 °F<br />

(-45 to 100 °C)<br />

-49 to 176 °F<br />

(-45 to 80 °C)<br />

—<br />

5 to 248 °F<br />

(-15 to 120 °C)<br />


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 1. Thermal Optimizer with Silicone 704 Fill Fluid Temperature Limits<br />

Humidity Limits<br />

0–100% relative humidity<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Turn-On Time<br />

3051SAL_C Performance within specifications less than 2.0 seconds after power is applied to the transmitter.<br />

3051L Performance within specifications less than 2.0 seconds (10.0 s for Profibus protocol) after power is applied to the transmitter<br />

2051L Performance within specifications less than 2.0 seconds after power is applied to the transmitter.<br />

ERS<br />

System:<br />

Performance within specifications less than 6.0 seconds after power is applied.<br />

Volumetric Displacement<br />

Less than 0.005 in3 (0.08 cm3 )<br />

Damping (1)<br />

Software damping is in addition to sensor module response time.<br />

3051SAL_C Analog output response to a step change is user-selectable from 0 to 60 seconds for one time constant.<br />

3051L Analog output response to a step input change is user-selectable from 0 to 36 seconds for one time constant.<br />

2051L Analog output response to a step input change is user-selectable from 0 to 25.6 seconds for one time constant.<br />

ERS<br />

System:<br />

The PHI <strong>and</strong> PLO Pressure measurements <strong>and</strong> the <strong>DP</strong> calculation may be independently dampened from 0 – 60 seconds for<br />

one time constant.<br />

(1) Does not apply to wireless option code X.<br />

95


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Physical Specifications<br />

Electrical Connections<br />

1 /2–14 NPT, PG 13.5, G 1 /2, <strong>and</strong> M20 × 1.5 conduit. HART interface<br />

connections fixed to terminal block.<br />

Non-Wetted Parts<br />

Capillary Armor is SST.<br />

96<br />

Electrical Housing<br />

Coplanar Sensor Module<br />

Housing<br />

Bolts<br />

Sensor Module Fill Fluid<br />

Process Fill Fluid<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

3051SAL 3051L 2051L<br />

Low-copper aluminum alloy or<br />

CF-8M (Cast 316 SST)<br />

NEMA 4X, IP 66, IP 68 (66 ft (20<br />

m) for 168 hours)<br />

Note: IP 68 not available with<br />

Wireless Output.<br />

CF-3M (Cast version of 316L<br />

SST, material per ASTM-A743)<br />

Plated carbon steel per ASTM<br />

A449, Type 1<br />

Austenitic 316 SST per ASTM<br />

F593<br />

ASTM A453, Class D, Grade 660<br />

SST<br />

ASTM A193, Grade B7M alloy<br />

steel<br />

ASTM A193, Class 2, Grade<br />

B8M SST<br />

Alloy K-500<br />

Silicone or inert halocarbon (Inert<br />

is not available with 3051S_CA).<br />

In-Line series uses Fluorinert ®<br />

FC-43.<br />

Syltherm XLT, Silicone 704,<br />

Silicone 200, inert, glycerin <strong>and</strong><br />

water,<br />

Neobee M-20, propylene glycol<br />

<strong>and</strong> water.<br />

Low-copper aluminum or CF-3M<br />

(Cast version of 316L SST,<br />

material per ASTM-A743). NEMA<br />

4X, IP 65, IP 66<br />

CF-3M (Cast version of 316L<br />

SST, material per ASTM-A743)<br />

ASTM A449, Type 1 (zinc-cobalt<br />

plated carbon steel)<br />

ASTM F593G, Condition CW1<br />

(Austenitic 316 SST)<br />

ASTM A193, Grade B7M (zinc<br />

plated alloy steel)<br />

Alloy K-500<br />

Silicone 200 or Fluorocarbon oil<br />

(Halocarbon or Fluorinert ® FC-43<br />

for 3051T)<br />

Syltherm XLT, Silicone 704,<br />

Silicone 200, inert, glycerin <strong>and</strong><br />

water, Neobee M-20 or propylene<br />

glycol <strong>and</strong> water<br />

Paint for Aluminum Housing Polyurethane Polyurethane Polyurethane<br />

Low-copper aluminum or CF-8M<br />

(Cast version of 316 SST).<br />

Enclosure Type 4X, IP 65, IP 66,<br />

IP 68<br />

CF-3M (Cast version of 316L<br />

SST, material per ASTM-A743)<br />

ASTM A449, Type 1 (zinc-cobalt<br />

plated carbon steel)<br />

ASTM F593G, Condition CW1<br />

(Austenitic 316 SST)<br />

ASTM A193, Grade B7M (zinc<br />

plated alloy steel)<br />

Silicone 200 or Fluorocarbon oil<br />

(Halocarbon or Fluorinert ® FC-43<br />

for 2051T)<br />

Syltherm XLT, Silicone 704,<br />

Silicone 200, inert, glycerin <strong>and</strong><br />

water, Neobee M-20 or propylene<br />

glycol <strong>and</strong> water<br />

Cover O-ring Nitrile butadiene (NBR) Nitrile butadiene (NBR) Nitrile butadiene (NBR)<br />

Wireless Antenna<br />

External Antenna (WK1 / WM1):<br />

PBT/ PC integrated<br />

omnidirectional antenna<br />

Remote Antenna (WN1):<br />

Fiberglass omnidirectional<br />

antenna<br />

N/A N/A<br />

Power Module<br />

Field replaceable, keyed<br />

connection eliminates the risk of<br />

incorrect installation, Intrinsically<br />

Safe Lithium-thionyl chloride<br />

Power Module with PBT<br />

enclosure<br />

N/A N/A


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

NOTE<br />

If a lower housing is supplied, then the following<br />

gaskets are the default gaskets for each seal.<br />

Wetted Materials<br />

<strong>Seal</strong> Gaskets<br />

FFW ThermoTork TN-9000 gasket<br />

FCW No gasket is supplied<br />

FUW No gasket is supplied<br />

FVW No gasket is supplied<br />

RCW C-4401 gasket<br />

RFW C-4401 gasket<br />

RTW C-4401 gasket<br />

PFW ThermoTork TN-9000 gasket<br />

PCW No gasket is supplied<br />

Transmitter flange is CF-3M (Cast version of 316L SST, material per ASTM-A743)<br />

Shipping Weights<br />

Table 49. 3051SAL Weights Without SuperModule Platform, Housing, or Transmitter Options<br />

Flange Flush<br />

lb. (kg)<br />

2-in. Ext.<br />

lb (kg)<br />

4-in. Ext.<br />

lb (kg)<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

6-in. Ext.<br />

lb (kg)<br />

2-in., 150 9.5 (4,3) — — —<br />

3-in., 150 15.7 (7,1) 16.4 (7,4) 17.6 (8,0) 18.9 (8,6)<br />

4-in., 150 21.2 (9,6) 20.9 (9,5) 22.1 (10,0) 23.4 (10,6)<br />

2-in., 300 11.3 (5,1) — — —<br />

3-in., 300 19.6 (8,9) 20.3 (9,2) 21.5 (9,8) 22.8 (10,3)<br />

4-in., 300 30.4 (13.8) 30.3 (13,7) 31.5 (14,3) 32.8 (14,9)<br />

2-in., 600 12.8 (5,8) — — —<br />

3-in., 600 22.1 (10,0) 22.8 (10,3) 24.0 (10,9) 25.3 (11,5)<br />

DN 50 / PN 40 11.3 (5,1) — — —<br />

DN 80 / PN 40 16.0 (7,3) 16.7 (7,6) 17.9 (8,1) 19.2 (8,7)<br />

DN 100 / PN 10/16 11.2 (5,1) 11.9 (5,4) 13.1 (5,9) 14.4 (6,5)<br />

DN 100 / PN 40 12.6 (5,7) 13.3 (6,0) 14.5 (6,6) 15.8 (7,1)<br />

Table 50. 3051SAM <strong>and</strong> 3051SAL Transmitter Option Weights<br />

Option Code Option Add lb (kg)<br />

1J, 1K, 1L SST PlantWeb Housing 3.5 (1,6)<br />

2J SST Junction Box Housing 3.4 (1,5)<br />

7J SST Quick Connect 0.4 (0,2)<br />

2A, 2B, 2C Aluminum Junction Box Housing 1.1 (0,5)<br />

1A, 1B, 1C Aluminum PlantWeb Housing 1.1 (0,5)<br />

M5 LCD Display for Aluminum PlantWeb Housing (1) ,<br />

LCD Display for SST PlantWeb Housing (1)<br />

0.8 (0,4)<br />

1.6 (0,7)<br />

Aluminum St<strong>and</strong>ard Cover 0.4 (0,2)<br />

SST St<strong>and</strong>ard Cover 1.3 (0,6)<br />

Aluminum Display Cover 0.7 (0,3)<br />

SST Display Cover 1.5 (0,7)<br />

Wireless Extended Cover 0.7 (0,3)<br />

LCD Display (2)<br />

0.1 (0,04)<br />

Junction Box Terminal Block 0.2 (0,1)<br />

PlantWeb Terminal Block 0.2 (0,1)<br />

Power Module 0.5 (0,2)<br />

(1) Includes LCD display <strong>and</strong> display cover.<br />

(2) Display only.<br />

97


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 51. 3051L Weights without Options<br />

98<br />

Flange<br />

Flush<br />

lb. (kg)<br />

2-in. Ext.<br />

lb (kg)<br />

4-in. Ext.<br />

lb (kg)<br />

6-in. Ext.<br />

lb (kg)<br />

2-in., 150 12.5 (5,7) — — —<br />

3-in., 150 17.5 (7,9) 19.5 (8,8) 20.5 (9,3) 21.5 (9,7)<br />

4-in., 150 23.5 (10,7) 26.5 (12,0) 28.5 (12,9) 30.5 (13,8)<br />

2-in., 300 17.5 (7,9) — — —<br />

3-in., 300 22.5 (10,2) 24.5 (11,1) 25.5 (11,6) 26.5 (12,0)<br />

4-in., 300 32.5 (14,7) 35.5 (16,1) 37.5 (17,0) 39.5 (17,9)<br />

2-in., 600 15.3 (6,9) — — —<br />

3-in., 600 25.2 (11,4) 27.2 (12,3) 28.2 (12,8) 29.2 (13,2)<br />

DN 50/PN 40 13.8 (6,2) — — —<br />

DN 80/PN 40 19.5 (8,8) 21.5 (9,7) 22.5 (10,2) 23.5 (10,6)<br />

DN 100/<br />

PN 10/16<br />

17.8 (8,1) 19.8 (9,0) 20.8 (9,5) 21.8 (9,9)<br />

DN 100/<br />

PN 40<br />

23.2 (10,5) 25.2 (11,5) 26.2 (11,9) 27.2 (12,3)<br />

Table 52. 3051L Transmitter Options Weights<br />

Option Add<br />

Code<br />

lb (kg)<br />

J, K, L, M Stainless Steel Housing (T) 3.9 (1,8)<br />

J, K, L, M Stainless Steel Housing (C, L, H, P) 3.1 (1,4)<br />

M5 LCD display for Aluminum Housing 0.5 (0,2)<br />

M6 LCD display for SST Housing 1.25 (0,6)<br />

Table 53. 2051L Weights without Options<br />

Flange<br />

Flush<br />

lb. (kg)<br />

2-in. Ext.<br />

lb (kg)<br />

4-in. Ext.<br />

lb (kg)<br />

6-in. Ext.<br />

lb (kg)<br />

2-in., 150 12.5 (5,7) — — —<br />

3-in., 150 17.5 (7,9) 19.5 (8,8) 20.5 (9,3) 21.5 (9,7)<br />

4-in., 150 23.5 (10,7) 26.5 (12,0) 28.5 (12,9) 30.5 (13,8)<br />

2-in., 300 17.5 (7,9) — — —<br />

3-in., 300 22.5 (10,2) 24.5 (11,1) 25.5 (11,6) 26.5 (12,0)<br />

4-in., 300 32.5 (14,7) 35.5 (16,1) 37.5 (17,0) 39.5 (17,9)<br />

DN 50/PN 40 13.8 (6,2) — — —<br />

DN 80/PN 40 19.5 (8,8) 21.5 (9,7) 22.5 (10,2) 23.5 (10,6)<br />

DN 100/<br />

PN 10/16<br />

17.8 (8,1) 19.8 (9,0) 20.8 (9,5) 21.8 (9,9)<br />

DN 100/<br />

PN 40<br />

23.2 (10,5) 25.2 (11,5) 26.2 (11,9) 27.2 (12,3)<br />

Table 54. 2051L Transmitter Options Weights<br />

Option Add<br />

Code<br />

lb (kg)<br />

J, K, L, M Stainless Steel Housing 3.9 (1,8)<br />

M5 LCD display for Aluminum Housing 0.5 (0,2)<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

SEAL SPECIFICATIONS<br />

Functional Specifications<br />

Hygienic <strong>Seal</strong> Approvals<br />

Hygienic <strong>Seal</strong>s: Tri-Clamp, tank spud, thin wall tank spud,<br />

Tri-Clamp inline, <strong>and</strong> Cherry Burrell “I” line seal conform to 3-A<br />

Hygienic St<strong>and</strong>ards for Sensor <strong>and</strong> Sensor Fittings <strong>and</strong><br />

Connections used on Milk <strong>and</strong> Milk Product Equipment, Number<br />

74-03.<br />

Hygienic Fill Fluids: The hygienic fill fluids glycerin & water <strong>and</strong><br />

Propylene Glycol & water meet United States Pharmacopeia<br />

(USP) <strong>and</strong> Food Chemical Codex (FCC) requirements <strong>and</strong> is<br />

Generally Recognized as Safe (GRAS) in accordance with the<br />

FDA Code of Federal Regulations Title 21. The hygienic fill fluid<br />

Neobee M-20 is approved under 21CFR 172.856 as a direct food<br />

additive <strong>and</strong> under 21 CFR 174.5 as an indirect food additive.<br />

Hygienic O-rings: The EPDM, Fluorocarbon (FMK), <strong>and</strong> Nitrile<br />

butadiene (NBR) O-rings for the SSW Tank Spud <strong>Seal</strong> meet 3-A<br />

Hygienic St<strong>and</strong>ard Number 18 Class 1 requirements. The EPDM<br />

O-ring also meets USP class VI approval requirements.<br />

Surface Finish Certification (Q16 Option)<br />

When ordering the Q16 option in the pressure transmitter model<br />

number, the surface finish of the seal diaphragm is certified per<br />

BPE 2002 requirements. This surface finish certification is<br />

available for Tri-Clamp, Tri-Clamp Inline, Tank Spud, <strong>and</strong> Thin Wall<br />

Tank Spud seal types.<br />

NACE St<strong>and</strong>ard (T Option)<br />

NACE (National Association of Corrosion Engineers) st<strong>and</strong>ard<br />

MR0175/ISO 15156 defines metallic material requirements for<br />

resistance to sulfide stress cracking when applied on petroleum<br />

production, drilling, gathering <strong>and</strong> flow line equipment, <strong>and</strong> field<br />

processing facilities to be used in H2S bearing hydrocarbon<br />

service. MR0103 provides material requirements exclusive to sour<br />

petroleum refining environments. Compliance guidelines are<br />

intended to include “wetted” materials as recommended by both<br />

NACE st<strong>and</strong>ards. The option code T in several of the general<br />

purpose seal types limits the wetted material offering.<br />

Metallurgical requirements for alloys used are virtually identical for<br />

the two st<strong>and</strong>ards, but application conditions enforced are different<br />

<strong>and</strong> can limit material acceptance. Contact an Emerson Process<br />

Management representative to aid in selecting the proper<br />

materials to meet the NACE st<strong>and</strong>ard.<br />

Material Traceability (Q8 Option)<br />

Material traceability is provided for the seal, upper housing, <strong>and</strong> if<br />

applicable, lower housing/flushing connection or diaphragm<br />

extension, upon selecting the option code Q8 in the pressure<br />

transmitter model number. Material traceability for the<br />

transmitter/seal system is provided per the DIN EN10204 3.1<br />

st<strong>and</strong>ard, <strong>and</strong> is only available for general purpose seal types.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Performance Specifications<br />

Instrument Toolkit calculates the remote seal system performance<br />

<strong>and</strong> validates model number configuration.<br />

Remote <strong>Seal</strong> System Performance Calculation<br />

Report (QZ Option)<br />

When the QZ option code is specified within the pressure<br />

transmitter model structure, Emerson will generate a remote seal<br />

system calculation report for the given application. This report<br />

quantifies all aspects of remote seal system performance including<br />

seal temperature effects, head temperature effects, seal response<br />

time, <strong>and</strong> transmitter total probable error.<br />

Physical Specifications<br />

Material of Construction<br />

Remote seal materials of construction (diaphragm, upper housing,<br />

flange, lower housing/flushing connection, bolts, <strong>and</strong><br />

gaskets/O-rings) are listed for each remote seal type. Fill fluids<br />

specifications are listed in Table 48.<br />

Tagging<br />

The <strong>1199</strong> remote seal model number is marked on the transmitter<br />

nameplate (neck or top label). The pressure transmitter will be<br />

tagged in accordance with customer requirements. The st<strong>and</strong>ard<br />

stainless steel tag is wired to the transmitter. Tag is 0.02-in. (0.051<br />

cm) thick with 0.125-in. (0.318 cm) high letters. A permanently<br />

attached tag is available upon request.<br />

Calibration<br />

<strong>Transmitters</strong> are factory calibrated to customer’s specified range.<br />

If calibration is not specified, then the transmitters are calibrated at<br />

maximum range. Calibration is performed at ambient temperature<br />

<strong>and</strong> pressure.<br />

Custom Configurations<br />

<strong>Rosemount</strong> 3051S, 3051, <strong>and</strong> 2051 (Option<br />

Code C1)<br />

If code C1 is ordered, the customer may specify the following<br />

data in addition to the st<strong>and</strong>ard configuration parameters.<br />

Refer to the respective configuration data sheet within the<br />

device PDS.<br />

Descriptor: 16 alphanumeric characters.<br />

Message: 32 alphanumeric characters.<br />

Date: Day, month, year.<br />

Damping: Sec.<br />

99


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

100<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> 3051S Liquid <strong>Level</strong> Certifications<br />

Approved Manufacturing Locations<br />

<strong>Rosemount</strong> Inc. — Chanhassen, Minnesota USA<br />

Emerson Process Management GmbH & Co. — Wessling,<br />

Germany<br />

Emerson Process Management Asia Pacific Private Limited —<br />

Singapore<br />

Beijing <strong>Rosemount</strong> Far East Instrument Co., LTD — Beijing, China<br />

Emerson Process Management LTDA — Sorocaba, Brazil<br />

Emerson Process Management (India) Pvt. Ltd. — Mumbai, India<br />

Emerson Process Management, Emerson FZE — Dubai, United<br />

Arab Emirates<br />

Ordinary Location Certification for FM<br />

As st<strong>and</strong>ard, the transmitter has been examined <strong>and</strong> tested to<br />

determine that the design meets basic electrical, mechanical, <strong>and</strong><br />

fire protection requirements by FM, a nationally recognized testing<br />

laboratory (NRTL) as accredited by the Federal Occupational<br />

Safety <strong>and</strong> Health Administration (OSHA).<br />

European Directive Information<br />

The EC declaration of conformity for all applicable European<br />

directives for this product can be found at www.rosemount.com. A<br />

hard copy may be obtained by contacting an Emerson Process<br />

Management representative.<br />

ATEX Directive (94/9/EC)<br />

Emerson Process Management complies with the<br />

ATEX Directive.<br />

European Pressure Equipment Directive (PED) (97/23/EC)<br />

Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option)<br />

Pressure <strong>Transmitters</strong> — QS Certificate of Assessment -<br />

EC No. 59552-2009-CE-HOU-DNV, Module H Conformity<br />

Assessment<br />

All other Model 3051S Pressure <strong>Transmitters</strong><br />

— Sound Engineering Practice<br />

Transmitter Attachments: Diaphragm <strong>Seal</strong> - Process Flange -<br />

Manifold — Sound Engineering Practice<br />

Primary Elements, Flowmeter<br />

— See appropriate Primary Element QIG<br />

Electro Magnetic Compatibility (EMC) (2004/108/EC)<br />

EN 61326-1:2006<br />

EN 61326-2-3:2006<br />

HART & FOUNDATION Fieldbus<br />

Hazardous Locations Certifications<br />

North American Certifications<br />

FM Approvals<br />

E5 Explosion-proof for Class I, Division 1, Groups B, C, <strong>and</strong> D,<br />

T5 (Ta = 85 °C); Dust Ignition-proof for Class II <strong>and</strong> Class III,<br />

Division 1, Groups E, F, <strong>and</strong> G, T5 (Ta = 85 °C); hazardous<br />

locations; enclosure Type 4X, conduit seal not required<br />

when installed according to <strong>Rosemount</strong> drawing<br />

03151-1003.<br />

I5/IE Intrinsically Safe for use in Class I, Division 1, Groups A, B,<br />

C, <strong>and</strong> D, T4 (Ta = 70 °C for output options A or X; Ta = 60<br />

°C for output option F or W); Class II, Division 1, Groups E,<br />

F, <strong>and</strong> G; Class III, Division 1; Class I, Zone 0 AEx ia IIC T4<br />

(Ta = 70 °C for output options A or X; Ta = 60 °C for output<br />

option F or W) when connected in accordance with<br />

<strong>Rosemount</strong> drawing 03151-1006; Non-Incendive for Class I,<br />

Division 2, Groups A, B, C, <strong>and</strong> D; T4 (Ta = 70 °C for output<br />

options A or X;<br />

Ta = 60 °C for output option F or W) Enclosure Type 4X<br />

For entity parameters see control drawing 03151-1006.<br />

Canadian St<strong>and</strong>ards Association (CSA)<br />

All CSA hazardous approved transmitters are certified per<br />

ANSI/ISA 12.27.01-2003.<br />

E6 Explosion-proof for Class I, Division 1, Groups B, C, <strong>and</strong> D;<br />

Dust Ignition-proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G; suitable for Class I, Division 2, Groups<br />

A, B, C, <strong>and</strong> D, when installed per <strong>Rosemount</strong> drawing<br />

03151-1013, CSA Enclosure Type 4X; conduit seal not<br />

required; Dual <strong>Seal</strong>.<br />

I6/IF Intrinsically Safe for Class I, Division 1, Groups A, B, C, <strong>and</strong><br />

D when connected in accordance with <strong>Rosemount</strong> drawings<br />

03151-1016; Dual <strong>Seal</strong>.<br />

For entity parameters see control drawing 03151-1016.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

European Certifications<br />

I1/IA ATEX Intrinsic Safety<br />

Certificate No.: BAS01ATEX1303X II 1G<br />

Ex ia IIC T4 (Ta = -60 °C to 70 °C) -HART/Remote<br />

Display/Quick Connect/HART Diagnostics<br />

Ex ia IIC T4 (Ta = -60 °C to 70 °C) -FOUNDATION fieldbus<br />

Ex ia IIC T4 (Ta = -60 °C to 40 °C) -FISCO<br />

1180<br />

Input Parameters<br />

Loop / Groups<br />

Power<br />

Ui = 30 V HART / FOUNDATION fieldbus/ Remote Display /<br />

Quick Connect / HART Diagnostics<br />

Ui = 17.5 V FISCO<br />

Ii = 300 mA HART / FOUNDATION fieldbus/ Remote Display /<br />

Quick Connect / HART Diagnostics<br />

Ii = 380 mA FISCO<br />

Pi = 1.0 W HART / Remote Display / Quick Connect /<br />

HART Diagnostics<br />

Pi = 1.3 W FOUNDATION fieldbus<br />

Pi = 5.32 W FISCO<br />

Ci = 30 nF SuperModule Platform<br />

Ci = 11.4 nF HART / HART Diagnostics / Quick Connect<br />

Ci = 0 FOUNDATION fieldbus / Remote Display / FISCO<br />

Li = 0 HART / FOUNDATION fieldbus/ FISCO / Quick<br />

Connect / HART Diagnostics<br />

Li = 60 µH Remote Display<br />

RTD Assembly (3051SFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63 W<br />

Special conditions for safe use (x)<br />

1. The apparatus, excluding the Types 3051 S-T <strong>and</strong> 3051<br />

S-C (In-line <strong>and</strong> Coplanar SuperModule Platforms<br />

respectively), is not capable of withst<strong>and</strong>ing the 500 V test<br />

as defined in Clause 6.3.12 of EN 60079-11. This must be<br />

considered during installation.<br />

2. The terminal pins of the Types 3051 S-T <strong>and</strong> 3051 S-C<br />

must be protected to IP20 minimum.<br />

N1 ATEX Type n<br />

Certificate No.: BAS01ATEX3304X II 3 G<br />

Ex nL IIC T4 (Ta = -40 °C TO 70 °C)<br />

Ui = 45 Vdc max<br />

Ci = 11.4 nF (Transmitter Output Option A)<br />

Ci = 0 (Transmitter Output Option F)<br />

Li = 0<br />

For remote display, Ci = 0, Li = 60 μH<br />

IP66<br />

Special conditions for safe use (x)<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by Clause 6.8.1 of EN 60079-15.<br />

This must be taken into account when installing the apparatus.<br />

NOTE<br />

RTD Assembly is not included with the 3051SFx Type n Approval.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

ND ATEX Dust<br />

Certificate No.: BAS01ATEX1374X II 1 D<br />

Ex tD A20 IP66 T105°C (-20 °C � Tamb � 85 °C)<br />

Vmax = 42.4 volts max<br />

IP66<br />

1180<br />

Special conditions for safe use (x)<br />

1. Cable entries must be used which maintain the ingress<br />

protection of the enclosure to at least IP66.<br />

2. Unused cable entries must be filled with suitable blanking<br />

plugs which maintain the ingress protection of the<br />

enclosure to at least IP66.<br />

3. Cable entries <strong>and</strong> blanking plugs must be suitable for the<br />

ambient range of the apparatus <strong>and</strong> capable of<br />

withst<strong>and</strong>ing a 7J impact test.<br />

4. The 3051S SuperModule must be securely screwed in<br />

place to maintain the ingress protection of the enclosure.<br />

(The 3051S SuperModule must be properly assembled to<br />

the 3051S housing to maintain ingress protection.)<br />

E1 ATEX Flameproof<br />

Certificate No.: KEMA00ATEX2143X II 1/2 G<br />

Ex d IIC T6 (-50 °C � Tamb � 65 °C)<br />

Ex d IIC T5 (-50 °C � Tamb � 80 °C)<br />

Vmax = 42.4 V<br />

1180<br />

Special conditions for safe use (x)<br />

1. The Ex d blanking elements, cable gl<strong>and</strong>s, <strong>and</strong> wiring<br />

shall be suitable for a temperature of 90 °C.<br />

2. The 3051S SuperModule contains a thin wall diaphragm.<br />

Installation, maintenance <strong>and</strong> use shall take into account<br />

the environmental conditions to which the diaphragm will<br />

be subjected. The manufacturer's instructions for<br />

maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

3. In case of repair, contact the manufacturer for information<br />

on the dimensions of the flameproof joints.<br />

Japanese Certifications<br />

E4 TIIS Flameproof<br />

Ex d IIC T6<br />

Certificate Description<br />

TC15682 Coplanar with Junction Box Housing<br />

TC15683 Coplanar with PlantWeb Housing<br />

TC15684 Coplanar with PlantWeb Housing<br />

<strong>and</strong> LCD Display<br />

TC15685 In-Line SST with Junction Box Housing<br />

TC15686 In-Line Alloy C-276 with Junction Box Housing<br />

TC15687 In-Line SST with PlantWeb Housing<br />

TC15688 In-Line Alloy C-276 with PlantWeb Housing<br />

TC15689 In-Line SST with PlantWeb Housing<br />

<strong>and</strong> LCD Display<br />

TC15690 In-Line Alloy C-276 with PlantWeb Housing<br />

<strong>and</strong> LCD Display<br />

TC17102 Remote Display<br />

TC17099 3051SFA/C/P SST/Alloy C-276 with<br />

PlantWeb Housing <strong>and</strong> LCD Display<br />

TC17100 3051SFA/C/P SST/Alloy C-276 with<br />

Junction Box Housing<br />

TC17101 3051SFA/C/P SST/Alloy C-276 with<br />

PlantWeb Housing <strong>and</strong> Remote Display<br />

101


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

China Certifications<br />

E3 China Flameproof, Dust Ignition-proof<br />

NEPSI Certificate No. (manufactured in Chanhassen, MN):<br />

GYJ091035<br />

Certificate No. (manufactured in Beijing, China <strong>and</strong><br />

Singapore): GYJ111400X<br />

Certificate No. (3051SFx RTC, BMMC, SMMC): GYJ071086<br />

Ex d IIC T5/T6<br />

DIP A20 Ta 105C IP66<br />

NOTE<br />

Refer to Appendix B of the 3051S Reference Manual (document<br />

number 00809-0100-4801) for Special Conditions for Safe Use.<br />

I3 China Intrinsic Safety, Dust Ignition-proof<br />

NEPSI Certificate No. (manufactured in Chanhassen, MN):<br />

GYJ081078<br />

Certificate No. (manufactured in Beijing, China <strong>and</strong><br />

Singapore): GYJ111401X<br />

Certificate No. (3051SFx RTC, BMMC, SMMC): GYJ071293<br />

Ex ia IIC T4<br />

DIP A21 T A T4 IP66<br />

NOTE<br />

Refer to Appendix B of the 3051S Reference Manual (document<br />

number 00809-0100-4801) for Special Conditions for Safe Use.<br />

Input Parameters<br />

Loop /<br />

Power<br />

Groups<br />

Ui = 30 V HART / FOUNDATION fieldbus / Remote Display /<br />

Quick Connect / HART Diagnostics<br />

Ii = 300 mA HART / FOUNDATION fieldbus / Remote Display /<br />

Quick Connect / HART Diagnostics<br />

Pi = 1.0 W HART / Remote Display / Quick Connect /<br />

HART Diagnostics<br />

Pi = 1.3 W FOUNDATION fieldbus<br />

Ci = 38 nF SuperModule Platform<br />

Ci = 11.4 nF HART / HART Diagnostics / Quick Connect<br />

Ci = 0 FOUNDATION fieldbus / Remote Display<br />

Li = 0 SuperModule Platform / FOUNDATION fieldbus<br />

Li = 2.4 µH HART / Quick Connect / HART Diagnostics<br />

Li = 58.2 µH Remote Display<br />

RTD Assembly (3051SFx Option T or R)<br />

U i = 5 Vdc<br />

I i = 500 mA<br />

P i = 0.63 W<br />

102<br />

N3 China Type n - Energy Limited<br />

NEPSI Certificate No.: GYJ101112X<br />

Ex nL IIC T5 (-40 °C ≤ Ta ≤ 70 °C)<br />

IP66<br />

Loop /<br />

Power<br />

Transmitter Output<br />

Ui = 30 V HART / FOUNDATION fieldbus<br />

Ii = 300 mA HART / FOUNDATION fieldbus<br />

Pi = 1.0 W HART<br />

Pi = 1.3 W FOUNDATION fieldbus<br />

Ci = 11.4 nF HART<br />

Ci = 0 nF FOUNDATION fieldbus<br />

Li = 0 µH HART (1) / FOUNDATION fieldbus<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

(1) For remote meter option (M7, M8, M9), L i = 60 µH.<br />

NOTE<br />

Refer to Appendix B of the 3051S Reference Manual (document<br />

number 00809-0100-4801) for Special Conditions for Safe Use.<br />

Brazil Certifications<br />

I2 INMETRO Intrinsic Safety<br />

Certificate number: CEPEL-EX-0722/05X<br />

(manufacturing in Chanhassen, MN <strong>and</strong> Singapore)<br />

Certificate number: CEPEL-EX-1414/07X<br />

(manufacturing in Brazil)<br />

INMETRO Marking: BR-Ex ia IIC T4 IP66W<br />

Special conditions for safe use (x)<br />

The apparatus, excluding the Types 3051S-T <strong>and</strong> 3051S-C<br />

(In-line <strong>and</strong> Coplanar SuperModule Platforms respectively),<br />

is not capable of withst<strong>and</strong>ing the 500 V test as defined in<br />

Clause 6.3.12 of IEC60079-11. This must be considered<br />

during installation.<br />

E2 INMETRO Flameproof<br />

Certificate number: CEPEL-EX-140/2003X<br />

(manufacturing in Chanhassen, MN <strong>and</strong> Singapore)<br />

Certificate number: CEPEL-EX-1413/07X<br />

(manufacturing in Brazil)<br />

INMETRO Marking: BR-Ex d IIC T5/T6 IP66W<br />

Special conditions for safe use (x)<br />

1. This device contains a thin wall diaphragm. Installation,<br />

maintenance, <strong>and</strong> use shall take into account the<br />

environmental conditions to which the diaphragm will be<br />

subjected. The manufacturer’s instructions for installation<br />

<strong>and</strong> maintenance shall be followed in detail to assure<br />

safety during its expected lifetime.<br />

2. For ambient temperature above 60 ºC, cable wiring must<br />

have minimum isolation temperature of 90 ºC, to be in<br />

accordance to equipment operation temperature.<br />

3. The accessory of cable entries or conduit must be<br />

certified as flameproof <strong>and</strong> needs to be suitable for use<br />

conditions.<br />

4. Where electrical entry is via conduit, the required sealing<br />

device must be assembled immediately close to<br />

enclosure.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

IECEx Certifications<br />

E7 IECEx Flameproof <strong>and</strong> Dust (each listed separately)<br />

IECEx Flameproof<br />

Certificate No.: IECExKEM08.0010X<br />

Ex d IIC T5 or T6 Ga/Gb<br />

T6 (-50 °C � Tamb � 65 °C)<br />

T5 (-50 °C � Tamb � 80 °C)<br />

Vmax = 42.4 V<br />

Special conditions for safe use (x)<br />

1. The Ex d blanking elements, cable gl<strong>and</strong>s, <strong>and</strong> wiring<br />

shall be suitable for a temperature of 90 °C.<br />

2. The 3051S SuperModule contains a thin wall diaphragm.<br />

Installation, maintenance, <strong>and</strong> use shall take into account<br />

the environmental conditions to which the diaphragm will<br />

be subjected. The manufacturer's instructions for<br />

maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

3. In case of repair, contact the manufacturer for information<br />

on the dimensions of the flameproof joints.<br />

IECEx Dust<br />

Certificate No. IECExBAS09.0014X<br />

Ex tD A20 IP66 T105 °C (-20 °C ≤ Ta ≤ 85 °C)<br />

Vmax = 42.4 V<br />

A = 22 mA<br />

IP66<br />

Special conditions for safe use (x)<br />

1. Cable entries must be used which maintain the ingress<br />

protection of the enclosure to at least IP66.<br />

2. Unused cable entries must be filled with suitable blanking<br />

plugs which maintain the ingress protection of the<br />

enclosure to at least IP66.<br />

3. Cable entries <strong>and</strong> blanking plugs must be suitable for the<br />

ambient range of the apparatus <strong>and</strong> capable of<br />

withst<strong>and</strong>ing a 7J impact test.<br />

4. The 3051S SuperModule must be securely screwed in<br />

place to maintain the ingress protection of the enclosure.<br />

(The 3051S SuperModule must be properly assembled to<br />

the 3051S housing to maintain ingress protection.)<br />

I7/IG IECEx Intrinsic Safety<br />

Certificate No.: IECExBAS04.0017X<br />

Ex ia IIC T4 (Ta = -60 °C to 70 °C) -HART/Remote<br />

Display/Quick Connect/HART Diagnostics<br />

Ex ia IIC T4 (Ta = -60 °C to 70 °C) -FOUNDATION fieldbus<br />

Ex ia IIC T4 (Ta = -60 °C to 40 °C) -FISCO<br />

IP66<br />

Input Parameters<br />

Loop / Power Groups<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Ui = 30 V HART / FOUNDATION fieldbus/ Remote<br />

Display / Quick Connect / HART<br />

Diagnostics<br />

Ui = 17.5 V FISCO<br />

Ii = 300 mA HART / FOUNDATION fieldbus/ Remote<br />

Display / Quick Connect / HART<br />

Diagnostics<br />

Ii = 380 mA FISCO<br />

Pi = 1.0 W HART / Remote Display / Quick<br />

Connect / HART Diagnostics<br />

Pi = 1.3 W FOUNDATION fieldbus<br />

Pi = 5.32 W FISCO<br />

Ci = 30 nF SuperModule Platform<br />

Ci = 11.4 nF HART / HART Diagnostics / Quick<br />

Connect<br />

Ci = 0 FOUNDATION fieldbus / Remote Display /<br />

FISCO<br />

Li = 0 HART / FOUNDATION fieldbus/ FISCO /<br />

Quick Connect / HART Diagnostics<br />

Li = 60�H Remote Display<br />

RTD Assembly (3051SFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63 W<br />

Special conditions for safe use (x)<br />

1. The 3051S HART 4-20 mA, 3051S FOUNDATION fieldbus,<br />

<strong>and</strong> 3051S FISCO are not capable of withst<strong>and</strong>ing the 500<br />

V test as defined in clause 6.3.12 of IEC 60079-11. This<br />

must be taken into account during installation.<br />

2. The terminal pins of the Types 3051S-T <strong>and</strong> 3051S-C must<br />

be protected to IP20 minimum.<br />

N7 IECEx Type n<br />

Certificate No.: IECExBAS04.0018X<br />

Ex nC IIC T4 (-40 °C ≤ Ta ≤ +70 °C)<br />

Ui = 45 Vdc Max<br />

IP66<br />

Special conditions for safe use (x)<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by Clause 8 of IEC 60079-15:1987.<br />

Combinations of Certifications<br />

Stainless steel certification tag is provided when optional approval<br />

is specified. Once a device labeled with multiple approval types is<br />

installed, it should not be reinstalled using any other approval<br />

types. Permanently mark the approval label to distinguish it from<br />

unused approval types.<br />

K1 Combination of E1, I1, N1, <strong>and</strong> ND<br />

K2 Combination of E2 <strong>and</strong> I2<br />

K5 Combination of E5 <strong>and</strong> I5<br />

K6 Combination of E6 <strong>and</strong> I6<br />

K7 Combination of E7, I7, <strong>and</strong> N7<br />

KA Combination of E1, I1, E6, <strong>and</strong> I6<br />

KB Combination of E5, I5, I6, <strong>and</strong> E6<br />

KC Combination of E5, E1, I5, <strong>and</strong> I1<br />

KD Combination of E5, I5, E6, I6, E1, <strong>and</strong> I1<br />

103


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

104<br />

3051S ERS System Certifications<br />

Approved Manufacturing Locations<br />

<strong>Rosemount</strong> Inc. – Chanhassen, Minnesota, USA<br />

Emerson Process Management GmbH & Co. – Wessling,<br />

Germany<br />

Emerson Process Management Asia Pacific Private Limited –<br />

Singapore<br />

Beijing <strong>Rosemount</strong> Far East Instrument Co., LTD – Beijing, China<br />

Ordinary Location Certification for FM<br />

Approvals<br />

As st<strong>and</strong>ard, the transmitter has been examined <strong>and</strong> tested to<br />

determine that the design meets basic electrical, mechanical, <strong>and</strong><br />

fire protection requirements by FM, a nationally recognized testing<br />

laboratory (NRTL) as accredited by the Federal Occupational<br />

Safety <strong>and</strong> Health Administration (OSHA).<br />

European Directive Information<br />

The EC declaration of conformity for all applicable European<br />

directives for this product can be found at www.rosemount.com. A<br />

hard copy may be obtained by contacting an Emerson Process<br />

Management representative.<br />

ATEX Directive (94/9/EC)<br />

Emerson Process Management complies with the<br />

ATEX Directive.<br />

European Pressure Equipment Directive (PED) (97/23/EC)<br />

Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option)<br />

Pressure <strong>Transmitters</strong> — QS Certificate of Assessment -<br />

EC No. 59552-2009-CE-HOU-DNV, Module H Conformity<br />

Assessment<br />

All other Model 3051S Pressure <strong>Transmitters</strong><br />

— Sound Engineering Practice<br />

Transmitter Attachments: Diaphragm <strong>Seal</strong> - Process Flange -<br />

Manifold — Sound Engineering Practice<br />

Primary Elements, Flowmeter<br />

— See appropriate Primary Element QIG<br />

Electro Magnetic Compatibility (EMC) (2004/108/EC)<br />

EN 61326-1:2006<br />

EN 61326-2-3:2006<br />

Hazardous Locations Certifications<br />

North American Certifications<br />

FM Approvals<br />

E5 Explosion-proof for Class I, Division 1, Groups B, C, <strong>and</strong> D;<br />

Dust Ignition-proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G; hazardous locations; enclosure Type<br />

4X, conduit seal not required.<br />

I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B,<br />

C, <strong>and</strong> D; Class II, Division 1, Groups E, F, <strong>and</strong> G; Class III,<br />

Division 1; Class I, Zone 0 AEx ia IIC when connected in<br />

accordance with <strong>Rosemount</strong> drawing 03151-1306;<br />

Non-Incendive for Class I, Division 2, Groups A, B, C, <strong>and</strong> D<br />

Enclosure Type 4X<br />

For entity parameters see control drawing 03151-1306.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Canadian St<strong>and</strong>ards Association (CSA)<br />

All CSA hazardous approved transmitters are certified per<br />

ANSI/ISA 12.27.01-2003.<br />

E6 Explosion-proof for Class I, Division 1, Groups B, C, <strong>and</strong> D;<br />

Dust Ignition-Proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G; suitable for Class I, Division 2, Groups<br />

A, B, C, <strong>and</strong> D, CSA Enclosure Type 4X; conduit seal not<br />

required; Dual <strong>Seal</strong>.<br />

I6 Intrinsically Safe for Class I, Division 1, Groups A, B, C, <strong>and</strong><br />

D when connected in accordance with <strong>Rosemount</strong> Drawings<br />

03151-1316; Dual <strong>Seal</strong>.<br />

For entity parameters see control drawing 03151-1316.<br />

European Certifications<br />

I1 ATEX Intrinsic Safety<br />

Certificate No.: BAS01ATEX1303X II 1G<br />

Ex ia IIC T4 (Ta = -60 °C to 70 °C)<br />

1180<br />

Table 55. Input Parameters<br />

Loop / Power<br />

Ui = 30 V<br />

Ii = 300 mA<br />

Pi = 1 W<br />

Ci = 12 nF<br />

Li = 33 �<br />

H<br />

Special Conditions for Safe Use (X)<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V test<br />

as defined in Clause 6.3.12 of EN 60079-11. This must be<br />

considered during installation.<br />

N1 ATEX Type n<br />

Certificate No.: BAS01ATEX3304X II 3 G<br />

Ex nL IIC T4 (Ta = -40 °C TO 70 °C)<br />

Ui = 45 Vdc max<br />

IP66<br />

Special conditions for safe use (x)<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by Clause 6.8.1 of EN 60079-15.<br />

This must be taken into account when installing the apparatus.


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

ND ATEX Dust<br />

Certificate No.: BAS01ATEX1374X II 1 D<br />

Ex tD A20 IP66 T105 °C (-20 °C � Tamb � 85 °C)<br />

Vmax = 42.4 V max<br />

IP66<br />

1180<br />

Special Conditions for safe use (X):<br />

1. Cable entries must be used which maintain the ingress<br />

protection of the enclosure to at least IP66.<br />

2. Unused cable entries must be filled suitable blanking<br />

plugs which maintain the ingress protection of the<br />

enclosure to at least IP66.<br />

3. Cable entries <strong>and</strong> blanking plugs must be suitable for the<br />

ambient range of the apparatus <strong>and</strong> capable of<br />

withst<strong>and</strong>ing a 7J impact test.<br />

4. Each 3051S ERS transmitter must be securely screwed<br />

in place to maintain the ingress protection of the<br />

enclosure. (The 3051S Super Module must be properly<br />

assembled to the 3051S housing to maintain ingress<br />

protection.)<br />

E1 ATEX Flameproof<br />

Certificate No.: KEMA00ATEX2143X II 1/2 G<br />

Ex d IIC T6 (-50 °C � Tamb � 65 °C)<br />

Ex d IIC T5 (-50 °C � Tamb � 80 °C)<br />

Vmax = 42.4 V<br />

1180<br />

Special Conditions for safe use (X):<br />

1. The Ex d blanking elements, cable gl<strong>and</strong>s <strong>and</strong> wiring<br />

shall be suitable for a temperature of 90 °C.<br />

2. Transmitter Model 3051S contains a thin wall diaphragm.<br />

Installation, maintenance, <strong>and</strong> use shall take into account<br />

the environmental conditions to which the diaphragm will<br />

be subjected. The manufacturer's instructions for<br />

maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

3. In case of repair, contact the manufacturer for information<br />

on the dimensions of the flameproof joints.<br />

Japanese Certifications<br />

E4 TIIS Flameproof: Consult factory for availability<br />

INMETRO Certifications<br />

E2 INMETRO Flameproof: Consult factory for availability<br />

I2 INMETRO Intrinsic Safety: Consult factory for availability<br />

China Certifications<br />

E3 China Flameproof, Dust Ignition-proof<br />

NEPSI Certificate No. (manufactured in Beijing, China):<br />

GYJ101345X<br />

Ex d II CT5/T6<br />

T5 (-50 °C � T a � 80 °C)<br />

T6 (-50 °C � T a � 65 °C)<br />

NOTE<br />

Refer to Appendix B of the 3051S ERS Reference Manual<br />

(document number 00809-0100-4804) for Special Conditions for<br />

Safe Use.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

I3 China Intrinsic Safety, Dust Ignition-proof<br />

NEPSI Certificate No. (manufactured in Beijing, China):<br />

GYJ111265X<br />

Ex ia IIC T4<br />

Maximum<br />

input<br />

voltage:<br />

U i (V)<br />

Maximum<br />

input<br />

current:<br />

I i (mA)<br />

Maximum<br />

input<br />

power:<br />

P i (W)<br />

Maximum internal<br />

parameters:<br />

Ci (nF) Li ( � H)<br />

30 300 1 12 33<br />

NOTE<br />

Refer to Appendix B of the 3051S ERS Reference Manual<br />

(document number 00809-0100-4804) for Special Conditions for<br />

Safe Use.<br />

IECEx Certifications<br />

I7 IECEx Intrinsic Safety<br />

Certificate No.: IECExBAS04.0017X<br />

Ex ia IIC T4 (Ta = -60 °C to 70 °C) -HART/Remote<br />

Display/Quick Connect/HART Diagnostics<br />

IP66<br />

Table 56. Input Parameters<br />

Loop / Power<br />

Ui = 30 V<br />

Ii = 300 mA<br />

Pi = 1 W<br />

Ci = 12 nF<br />

Li = 33 �<br />

H<br />

Special conditions for safe use (X)<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V test<br />

as defined in clause 6.3.12 of IEC 60079-11. This must be<br />

taken into account during installation.<br />

N7 IECEx Type n<br />

Certificate No.: IECExBAS04.0018X<br />

Ex nC IIC T4 (-40 °C ≤ T a ≤ +70 °C)<br />

U i = 45 Vdc Max<br />

IP66<br />

Special conditions for safe use (x)<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by Clause 8 of IEC 60079-15:1987.<br />

105


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

E7 IECEx Flameproof <strong>and</strong> Dust (each listed separately)<br />

IECEx Flameproof<br />

Certificate No.: IECExKEM08.0010X<br />

Ex d IIC T6 (-50 °C � Tamb � 65 °C)<br />

Ex d IIC T5 (-50 °C � Tamb � 80 °C)<br />

Vmax = 42.4 V<br />

Special conditions for safe use (X)<br />

1. The Ex d blanking elements, cable gl<strong>and</strong>s <strong>and</strong> wiring<br />

shall be suitable for a temperature of 90 °C.<br />

2. Transmitter Model 3051S contains a thin wall diaphragm.<br />

Installation, maintenance, <strong>and</strong> use shall take into account<br />

the environmental conditions to which the diaphragm will<br />

be subjected. The manufacturer's instructions for<br />

maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

3. In case of repair, contact the manufacturer for information<br />

on the dimensions of the flameproof joints.<br />

106<br />

IECEx Dust<br />

Certificate No. IECExBAS09.0014X<br />

Ex tD A20 IP66 T105°C (-20 °C ≤ T amb ≤ 85 °C)<br />

Vmax = 42.4 V<br />

A = 22 mA<br />

IP66<br />

Special conditions for safe use (x)<br />

1. Cable entries must be used which maintain the ingress<br />

protection of the enclosure to at least IP66.<br />

2. Unused cable entries must be filled with suitable blanking<br />

plugs which maintain the ingress protection of the<br />

enclosure to at least IP66.<br />

3. Cable entries <strong>and</strong> blanking plugs must be suitable for the<br />

ambient range of the apparatus <strong>and</strong> capable of<br />

withst<strong>and</strong>ing a 7J impact test.<br />

4. Each 3051S ERS sensor must be securely screwed in<br />

place to maintain the ingress protection of the enclosure.<br />

(Each sensor module must be properly assembled to the<br />

housing to maintain ingress protection.)<br />

Combinations of Certifications<br />

Stainless steel certification tag is provided when optional approval<br />

is specified. Once a device labeled with multiple approval types is<br />

installed, it should not be reinstalled using any other approval<br />

types. Permanently mark the approval label to distinguish it from<br />

unused approval types.<br />

K1 Combination of E1, I1, N1, <strong>and</strong> ND<br />

K2 Combination of E2 <strong>and</strong> I2<br />

K5 Combination of E5 <strong>and</strong> I5<br />

K6 Combination of E6 <strong>and</strong> I6<br />

K7 Combination of E7, I7, <strong>and</strong> N7<br />

KA Combination of E1, E6, I1, <strong>and</strong> I6<br />

KB Combination of E5, E6, I1, <strong>and</strong> I6<br />

KC Combination of E5, E1, I5, <strong>and</strong> I1<br />

KD Combination of E5, E6, E1, I5, I6, <strong>and</strong> I1<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Approved Manufacturing Locations<br />

<strong>Rosemount</strong> Inc. — Chanhassen, Minnesota USA<br />

Emerson Process Management GmbH & Co. — Wessling,<br />

Germany<br />

Emerson Process Management Asia Pacific<br />

Private Limited — Singapore<br />

Beijing <strong>Rosemount</strong> Far East Instrument Co., LTD — Beijing, China<br />

European Directive Information<br />

The EC declaration of conformity for all applicable European<br />

directives for this product can be found on the <strong>Rosemount</strong> website<br />

at www.rosemount.com. A hard copy may be obtained by<br />

contacting an Emerson Process Management representative.<br />

ATEX Directive (94/9/EC)<br />

All 3051 transmitters comply with the ATEX Directive.<br />

European Pressure Equipment Directive (PED) (97/23/EC)<br />

3051CA4; 3051CG2, 3, 4, 5; 3051CD2, 3, 4, 5<br />

(also with P9 option); 3051HD2, 3, 4, 5; 3051HG2, 3, 4, 5;<br />

3051PD2, 3; <strong>and</strong> 3051PG2, 3, 4, 5 Pressure <strong>Transmitters</strong><br />

— QS Certificate of Assessment -<br />

EC No. 59552-2009-CE-HOU-DNV<br />

Module H Conformity Assessment<br />

All other 3051/3001 Pressure <strong>Transmitters</strong><br />

— Sound Engineering Practice<br />

Transmitter Attachments: Diaphragm <strong>Seal</strong> - Process<br />

Flange - Manifold<br />

— Sound Engineering Practice<br />

Electro Magnetic Compatibility (EMC) (2004/108/EC)<br />

All 3051 Pressure <strong>Transmitters</strong> meet all of the requirements of<br />

EN61326-1:2006 EN61326-2-3: 2006 <strong>and</strong> NAMUR NE-21<br />

Ordinary Location Certification for Factory Mutual<br />

As st<strong>and</strong>ard, the transmitter has been examined <strong>and</strong> tested to<br />

determine that the design meets basic electrical, mechanical,<br />

<strong>and</strong> fire protection requirements by FM, a nationally recognized<br />

testing laboratory (NRTL) as accredited by the Federal<br />

Occupational Safety <strong>and</strong> Health Administration (OSHA).<br />

3051L Product Certifications<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

3051L HART PROTOCOL<br />

Hazardous Locations Certifications<br />

North American Certifications<br />

FM Approvals<br />

E5 Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II, Division 1, Groups E, F, <strong>and</strong><br />

G. Dust-Ignition-Proof for Class III, Division 1.<br />

Factory <strong>Seal</strong>ed, Enclosure Type 4X<br />

I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B,<br />

C, <strong>and</strong> D; Class II, Division 1, Groups E, F, <strong>and</strong> G; Class III,<br />

Division 1 when connected per <strong>Rosemount</strong> drawing<br />

03031-1019; Non-incendive for Class I, Division 2, Groups<br />

A, B, C, <strong>and</strong> D.<br />

Temperature Code:T4 (Ta = 40 °C), T3 (Ta = 85 °C),<br />

Enclosure Type 4X<br />

For input parameters see control drawing 03031-1019.<br />

Canadian St<strong>and</strong>ards Association (CSA)<br />

All CSA hazardous approved transmitters are certified per<br />

ANSI/ISA 12.27.01-2003.<br />

E6 Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G. Suitable for Class I, Division 2 Groups<br />

A, B, C, <strong>and</strong> D for indoor <strong>and</strong> outdoor hazardous locations.<br />

Enclosure type 4X, factory sealed<br />

C6 Explosion-Proof <strong>and</strong> intrinsically safe approval. Intrinsically<br />

safe for Class I, Division 1, Groups A, B, C, <strong>and</strong> D when<br />

connected in accordance with <strong>Rosemount</strong> drawings<br />

03031-1024. Temperature Code T3C.<br />

Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G. Suitable for Class I, Division 2 Groups<br />

A, B, C, <strong>and</strong> D hazardous locations. Enclosure type 4X,<br />

factory sealed<br />

For input parameters see control drawing 03031-1024.<br />

European Certifications<br />

I1 ATEX Intrinsic Safety <strong>and</strong> Dust<br />

Certification No.: BAS 97ATEX1089X II 1 GD<br />

Ex ia IIC T4 (–60 � T a � +70 °C)<br />

Dust Rating: Ex tD A20 T80 °C (–20 � T a � 40 °C) IP66<br />

1180<br />

Table 57. Input Parameters<br />

Ui = 30 V<br />

Ii = 200 mA<br />

Pi = 0.9 W<br />

Ci = 0.012 µF<br />

Table 58. RTD Assembly (3051CFx Option T or R)<br />

U i = 5 Vdc<br />

I i = 500 mA<br />

P i = 0.63 W<br />

107


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing the<br />

500 V insulation test required by Clause 6.3.12 of<br />

EN60079-11. This must be taken into account when<br />

installing the apparatus.<br />

The enclosure may be made of aluminium alloy <strong>and</strong> given a<br />

protective polyurethane paint finish; however, care should<br />

be taken to protect it from impact or abrasion if located in<br />

Zone 0.<br />

N1 ATEX Type n <strong>and</strong> Dust<br />

Certification No.: BAS 00ATEX3105X II 3 GD<br />

Ui = 55 Vdc max<br />

Ex nA nL T5 (–40 °C � Tamb � 70 °C)<br />

Dust rating: Ex tD A22 T80 °C (–20 � Ta � 40 °C) IP66<br />

108<br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing a 500<br />

V r.m.s. test to case. This must be taken into account on any<br />

installation in which it is used, for example, by assuring that<br />

the supply to the apparatus is galvanically isolated.<br />

E8 ATEX Flame-Proof <strong>and</strong> Dust<br />

Certification No.: KEMA 00ATEX2013X II 1 /2 GD<br />

Ex d IIC T6 (–50 � Ta � 65 °C)<br />

T5 (–50 � Ta � 80 °C)<br />

Dust rating: Ex tD A20/A21 T90 °C, IP66<br />

1180<br />

Vmax = 55 Vdc<br />

Special Conditions for Safe Use (X):<br />

This device contains a thin wall diaphragm. Installation,<br />

maintenance, <strong>and</strong> use shall take into account the<br />

environmental conditions to which the diaphragm will be<br />

subjected. The manufacturer’s instructions for installation<br />

<strong>and</strong> maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

In case of repair, contact <strong>Rosemount</strong> for dimensions of the<br />

flameproof joints.<br />

Japanese Certifications<br />

E4 TIIS Flame-Proof<br />

Ex d IIC T6<br />

Certificate Description<br />

C15850 3051C/D/1 4–20 mA HART<br />

— no display<br />

C15851 3051C/D/1 4–20 mA HART<br />

— with display<br />

IECEx Certifications<br />

I7 IECEx Intrinsic Safety<br />

Certification No.: IECEx BAS 09.0076X<br />

Ex ia IIC T4 (–60 °C � T a � 70 °C)<br />

IP66<br />

TABLE 59. Input Parameters<br />

Ui = 30 V<br />

Ii = 200 mA<br />

Pi = 0.9 W<br />

Ci = 0.012 µF<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

TABLE 60. RTD Assembly (3051CFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63 W<br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing the<br />

500 V insulation test required by Clause 6.3.12 of IEC<br />

60079-11. This must be taken into account when installing<br />

the apparatus.<br />

The enclosure may be made of aluminium alloy <strong>and</strong> given a<br />

protective polyurethane paint finish; however care should be<br />

taken to protect it from impact or abrasion located in Zone 0.<br />

E7 IECEx Explosion-Proof (Flame-Proof)<br />

Certification No.: IECEx KEM 09.0034X<br />

Ga/Gb Ex d IIC T6 or T5<br />

Ex tD A20/A21 IP66 T90 °C<br />

IP66<br />

Special Conditions for Safe Use (X):<br />

This device contains a thin wall diaphragm. Installation,<br />

maintenance, <strong>and</strong> use shall take into account the<br />

environmental conditions to which the diaphragm will be<br />

subjected. The manufacturer's instructions for installation<br />

<strong>and</strong> maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

For information on the dimensions of the flameproof joints<br />

the manufacturer shall be contacted.<br />

N7 IECEx Type n<br />

Certification No.: IECEx BAS 09.0077X<br />

Ex nA nL IIC T5 (–40 °C � Ta � 70 °C)<br />

IP66<br />

Special Conditions for Safe Use (X):<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by clause 6.8.1 of IEC 60079-15.<br />

This must be taken into account when installing the<br />

apparatus.<br />

Combinations of Certifications<br />

Stainless steel certification tag is provided when optional approval<br />

is specified. Once a device labeled with multiple approval types is<br />

installed, it should not be reinstalled using any other approval<br />

types. Permanently mark the approval label to distinguish it from<br />

unused approval types.<br />

K5 E5 <strong>and</strong> I5 combination<br />

KB K5 <strong>and</strong> C6 combination<br />

KD K5, C6, I1, <strong>and</strong> E8 combination<br />

K6 C6, I1, <strong>and</strong> E8 combination<br />

K8 E8 <strong>and</strong> I1 combination<br />

K7 E7, I7, <strong>and</strong> N7 combination


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

3051L FIELDBUS PROTOCOL<br />

Hazardous Locations Certifications<br />

North American Certifications<br />

FM Approvals<br />

E5 Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II, Division 1, Groups E, F, <strong>and</strong><br />

G. Dust-Ignition-Proof for Class III, Division 1. Factory<br />

sealed. Enclosure Type 4X.<br />

I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B,<br />

C, <strong>and</strong> D; Class II, Division 1, Groups E, F, <strong>and</strong> G; Class III,<br />

Division 1 when connected per <strong>Rosemount</strong> drawing<br />

03031-1019; Non-incendive for Class I, Division 2, Groups<br />

A, B, C, <strong>and</strong> D.<br />

Temperature Code: T4 (Ta = 60 °C), Enclosure Type 4X<br />

For input parameters see control drawing 03031-1019.<br />

Canadian St<strong>and</strong>ards Association (CSA)<br />

All CSA hazardous approved transmitters are certified per<br />

ANSI/ISA 12.27.01-2003.<br />

E6 Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G. Suitable for Class I, Division 2 Groups<br />

A, B, C, <strong>and</strong> D for indoor <strong>and</strong> outdoor hazardous locations.<br />

Enclosure type 4X, factory sealed<br />

C6 Explosion-Proof <strong>and</strong> intrinsically safe approval. Intrinsically<br />

safe for Class I, Division 1, Groups A, B, C, <strong>and</strong> D when<br />

connected in accordance with <strong>Rosemount</strong> drawings<br />

03031-1024. Temperature Code T3C.<br />

Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G. Suitable for Class I, Division 2 Groups<br />

A, B, C, <strong>and</strong> D hazardous locations. Enclosure type 4X,<br />

factory sealed<br />

For input parameters see control drawing 03031-1024.<br />

European Certifications<br />

I1 ATEX Intrinsic Safety <strong>and</strong> Dust<br />

Certification No.: BAS 98ATEX1355X II 1 GD<br />

Ex ia IIC T4 (Tamb = –60 to +60 °C)<br />

Dust Rating: Ex tD A20 T70 °C (Tamb –20 to 40 °C) IP66<br />

1180<br />

Table 61. Input Parameters<br />

U i = 30 V<br />

I i = 300 mA<br />

P i = 1.3 W<br />

C i = 0 µF<br />

Table 62. RTD Assembly (3051CFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63 W<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Special Conditions for Safe Use (X):<br />

The device is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by Clause 6.3.12 of EN60079-11.<br />

This must be taken into account when installing the<br />

apparatus.<br />

The enclosure may be made of aluminium alloy <strong>and</strong> given a<br />

protective polyurethane paint finish; however, care should<br />

be taken to protect it from impact or abrasion if located in<br />

Zone 0.<br />

IA ATEX FISCO Intrinsic Safety<br />

Certification No.: BAS 98ATEX1355X II 1 G<br />

Ex ia IIC T4 (Tamb = –60 to +60 °C)<br />

IP66<br />

1180<br />

Table 63. Input Parameters<br />

U i = 17.5 V<br />

I i = 380 mA<br />

P i = 5.32 W<br />

C i = � 5 µF<br />

L i = ��10 µH<br />

Special Conditions for Safe Use (X):<br />

The device is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by Clause 6.3.12 of EN60079-11.<br />

This must be taken into account when installing the<br />

apparatus.<br />

The enclosure may be made of aluminium alloy <strong>and</strong> given a<br />

protective polyurethane paint finish; however, care should<br />

be taken to protect it from impact or abrasion if located in<br />

Zone 0.<br />

N1 ATEX Type n <strong>and</strong> Dust<br />

Certification No.: BAS 98ATEX3356X II 3 GD<br />

Ui = 40 Vdc max<br />

Ex nL IIC T5 (Ta = –40 °C to 70 °C)<br />

Dust rating: Ex tD A22 T80 °C (Tamb = –20 to 40 °C) IP66<br />

Special Conditions for Safe Use (X):<br />

The device is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by Clause 6.8.1 of EN60079-15. This<br />

must be taken into account when installing the apparatus.<br />

E8 ATEX Flame-Proof <strong>and</strong> Dust<br />

Certification No.: KEMA 00ATEX2013X II 1 /2 GD<br />

Ex d IIC T6 (Tamb = –50 to 65 °C)<br />

T5 (Tamb = –50 to 80 °C)<br />

Dust rating: Ex tD A20/21 T90 °C, IP66<br />

1180<br />

Vmax = 55 Vdc<br />

Special Conditions for Safe Use (X):<br />

This device contains a thin wall diaphragm. Installation,<br />

maintenance, <strong>and</strong> use shall take into account the<br />

environmental conditions to which the diaphragm will be<br />

subjected. The manufacturer’s instructions for installation<br />

<strong>and</strong> maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

In case of repair, contact <strong>Rosemount</strong> for dimensions of the<br />

flameproof joints.<br />

109


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Japanese Certifications<br />

E4 TIIS Flame-Proof<br />

Ex d IIC T6<br />

IECEx Certifications<br />

I7 IECEx Intrinsic Safety<br />

Certification No.: IECEx BAS 09.0076X<br />

Ex ia IIC T4 (–60 °C � Ta � 60 °C)<br />

IP66<br />

110<br />

Certificate Description<br />

C15852 3051C/D/1 FOUNDATION Fieldbus<br />

— no display<br />

C15853 3051C/D/1 FOUNDATION Fieldbus<br />

— with display<br />

TABLE 64. Input Parameters<br />

Ui = 30 V<br />

Ii = 300 mA<br />

Pi = 1.3 W<br />

Ci = 0 µF<br />

Li = 0 µH<br />

TABLE 65. RTD Assembly (3051CFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63W<br />

Special Conditions for Safe Use (X):<br />

1. If the apparatus is fitted with an optional 90 V transient<br />

suppressor, it is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by clause 6.3.12 of IEC 60079-11.<br />

This must be taken into account when installing the<br />

apparatus.<br />

2. The enclosure may be made of aluminium alloy <strong>and</strong> given<br />

a protective polyurethane paint finish; however, care<br />

should be taken to protect it from impact or abrasion if<br />

located in Zone 0.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

E7 IECEx Explosion-Proof (Flame-Proof)<br />

Certification No.: IECEx KEM 09.0034X<br />

Ga/Gb Ex d IIC T6 or T5<br />

Ex tD A20/A21 IP66 T90 °C<br />

IP66<br />

Special Conditions for Safe Use (X):<br />

This device contains a thin wall diaphragm. Installation,<br />

maintenance, <strong>and</strong> use shall take into account the<br />

environmental conditions to which the diaphragm will be<br />

subjected. The manufacturer's instructions for installation<br />

<strong>and</strong> maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

For information on the dimensions of the flameproof joints<br />

the manufacturer shall be contacted.<br />

N7 IECEx Type n<br />

Certification No.: IECEx BAS 09.0077X<br />

Ex nA nL IIC T5 (–40 °C � Ta � 70 °C)<br />

IP66<br />

Special Conditions for Safe Use (X):<br />

The apparatus is not capable of withst<strong>and</strong>ing the 500 V<br />

insulation test required by clause 6.8.1 of IEC 60079-15.<br />

This must be taken into account when installing the<br />

apparatus.<br />

Combinations of Certifications<br />

Stainless steel certification tag is provided when optional approval<br />

is specified. Once a device labeled with multiple approval types is<br />

installed, it should not be reinstalled using any other approval<br />

types. Permanently mark the approval label to distinguish it from<br />

unused approval types.<br />

K5 E5 <strong>and</strong> I5 combination<br />

KB K5 <strong>and</strong> C6 combination<br />

KD K5, C6, I1, <strong>and</strong> E8 combination<br />

K6 C6, I1, <strong>and</strong> E8 combination<br />

K8 E8 <strong>and</strong> I1 combination<br />

K7 E7, I7, <strong>and</strong> N7 combination


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Approved Manufacturing Locations<br />

<strong>Rosemount</strong> Inc. — Chanhassen, Minnesota USA<br />

Emerson Process Management GmbH & Co. — Wessling,<br />

Germany<br />

Emerson Process Management Asia Pacific<br />

Private Limited — Singapore<br />

Beijing <strong>Rosemount</strong> Far East Instrument Co., LTD — Beijing, China<br />

European Directive Information<br />

The EC declaration of conformity for all applicable European<br />

directives for this product can be found on the <strong>Rosemount</strong> website<br />

at www.rosemount.com. A hard copy may be obtained by<br />

contacting an Emerson Process Management representative.<br />

ATEX Directive (94/9/EC)<br />

All 2051 transmitters comply with the ATEX Directive.<br />

European Pressure Equipment Directive (PED) (97/23/EC)<br />

2051CG2, 3, 4, 5; 2051CD2, 3, 4, 5 (also with P9 option)<br />

— QS Certificate of Assessment -<br />

EC No. 59552-2009-CE-HOU-DNV<br />

Module H Conformity Assessment<br />

All other 2051 Pressure <strong>Transmitters</strong><br />

— Sound Engineering Practice<br />

Transmitter Attachments: Diaphragm <strong>Seal</strong> - Process<br />

Flange - Manifold<br />

— Sound Engineering Practice<br />

Electro Magnetic Compatibility (EMC) (2004/108/EC)<br />

All 2051 Pressure <strong>Transmitters</strong> meet all of the requirements of<br />

EN61326:2006 <strong>and</strong> NAMUR NE-21.<br />

Ordinary Location Certification for Factory Mutual<br />

As st<strong>and</strong>ard, the transmitter has been examined <strong>and</strong> tested to<br />

determine that the design meets basic electrical, mechanical,<br />

<strong>and</strong> fire protection requirements by FM, a nationally recognized<br />

testing laboratory (NRTL) as accredited by the Federal<br />

Occupational Safety <strong>and</strong> Health Administration (OSHA).<br />

2051L HART PROTOCOL<br />

Hazardous Locations Certifications<br />

North American Certifications<br />

FM Approvals<br />

E5 Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II, Division 1, Groups E, F, <strong>and</strong><br />

G. Dust-Ignition-Proof for Class III, Division 1.<br />

T5 (Ta = 85 °C), Factory <strong>Seal</strong>ed, Enclosure Type 4X<br />

2051L Product Certifications<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B,<br />

C, <strong>and</strong> D; Class 1, Zone 0 AEx ia T4; Class II, Division 1,<br />

Groups E, F, <strong>and</strong> G; Class III, Division 1 when connected<br />

per <strong>Rosemount</strong> drawing 02051-1009; Non-incendive for<br />

Class I, Division 2, Groups A, B, C, <strong>and</strong> D.<br />

Temperature Code:T4 (Ta = 70 °C),<br />

Enclosure Type 4X<br />

For input parameters see control drawing 02051-1009.<br />

Canadian St<strong>and</strong>ards Association (CSA)<br />

All CSA hazardous approved transmitters are certified per<br />

ANSI/ISA 12.27.01-2003.<br />

E6 Explosion-Proof for Class I, Division 1, Groups B, C, <strong>and</strong> D.<br />

Dust-Ignition-Proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G. Suitable for Class I, Division 2 Groups<br />

A, B, C, <strong>and</strong> D for indoor <strong>and</strong> outdoor hazardous locations.<br />

Enclosure type 4X, factory sealed<br />

I6 Intrinsically safe approval. Intrinsically safe for Class I,<br />

Division 1, Groups A, B, C, <strong>and</strong> D when connected in<br />

accordance with <strong>Rosemount</strong> drawing 02051-1008.<br />

Temperature Code T3C; Ex ia IIC T3C.<br />

Dust-Ignition-Proof for Class II <strong>and</strong> Class III, Division 1,<br />

Groups E, F, <strong>and</strong> G. Suitable for Class I, Division 2 Groups<br />

A, B, C, <strong>and</strong> D hazardous locations. Enclosure type 4X,<br />

factory sealed<br />

For input parameters see control drawing 02051-1008.<br />

European Certifications<br />

I1 ATEX Intrinsic Safety<br />

Certification No. Baseefa08ATEX0129X II 1 G<br />

Ex ia IIC T4 (–60 � T a � +70 °C)<br />

IP66 IP68<br />

1180<br />

Table 66. Input Parameters<br />

U i = 30 V<br />

I i = 200 mA<br />

P i = 1.0 W<br />

C i = 0.012 µF<br />

L i = 10 µH<br />

Table 67. RTD Assembly (2051CFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63 W<br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing the<br />

500 V insulation test required by Clause 6.3.12 of<br />

EN60079-11. This must be taken into account when<br />

installing the apparatus.<br />

111


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

N1 ATEX Type n<br />

Certification No. Baseefa08ATEX0130X II 3 G<br />

Ex nAnL IIC T4 (–40 � T a � +70 °C)<br />

U i = 42.4 Vdc max<br />

IP66<br />

112<br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing a 500<br />

V r.m.s. test to case. This must be taken into account on any<br />

installation in which it is used, for example by assuring that<br />

the supply to the apparatus is galvanically isolated.<br />

E1 ATEX Flame-Proof<br />

Certification No. KEMA 08ATEX0090X II 1 /2 G<br />

Ex d IIC T6 (–50 � Ta � 65 °C)<br />

Ex d IIC T5 (–50 � Ta � 80 °C)<br />

IP66<br />

1180<br />

Vmax = 42.4 Vdc<br />

Special Conditions for Safe Use (X):<br />

This device contains a thin wall diaphragm. Installation,<br />

maintenance, <strong>and</strong> use shall take into account the<br />

environmental conditions to which the diaphragm will be<br />

subjected. The manufacturer’s instructions for installation<br />

<strong>and</strong> maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

The Ex d blanking elements, cable gl<strong>and</strong>s, <strong>and</strong> wiring shall<br />

be suitable for a temperature of 90 °C.<br />

In case of repair, contact the manufacturer for information on<br />

the dimensions of the flameproof joints.<br />

ND ATEX Dust<br />

Certification No. Baseefa08ATEX0182X II 1 D<br />

Dust Rating: II 1 D Ex tD A20 T115 °C (-20 °C ��Ta � 85 °C)<br />

IP66 IP68<br />

Vmax = 42.4 Vdc<br />

A = 22 mA<br />

1180<br />

Special Conditions for Safe Use (X):<br />

1. The user must ensure that the maximum rated voltage<br />

<strong>and</strong> current (42.4 V, 22 mA, DC) are not exceeded. All<br />

connections to other apparatus or associated apparatus<br />

shall have control over this voltage <strong>and</strong> current equivalent<br />

to a category “ib” circuit according to EN 60079-1.<br />

2. Cable entries must be used which maintain the ingress<br />

protection of the enclosure to at least IP66.<br />

3. Unused cable entries must be filled with suitable blanking<br />

plugs which maintain the ingress protection of the<br />

enclosure to at least IP66.<br />

4. Cable entries <strong>and</strong> blanking plugs must be suitable for the<br />

ambient range of the apparatus <strong>and</strong> capable of<br />

withst<strong>and</strong>ing a 7J impact test.<br />

IECEx Certifications<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

I7 IECEx Intrinsic Safety<br />

Certification No. IECExBAS08.0045X II 1 G<br />

Ex ia IIC T4 (–60 � T a � +70 °C)<br />

1180<br />

Table 68. Input Parameters<br />

Ui = 30 V<br />

Ii = 200 mA<br />

Pi = 1.0 W<br />

Ci = 0.012 µF<br />

Li = 10 µH<br />

Table 69. RTD Assembly (2051CFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63 W<br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing the<br />

500 V insulation test required by Clause 6.3.12 of<br />

IEC60079-11. This must be taken into account when<br />

installing the apparatus.<br />

E7 IECEx Explosion-Proof (Flame-Proof)<br />

Certification No. IECEx KEM 08.0024X II 1 /2 G<br />

Ex d IIC T6 (–50 � Ta � 65 °C)<br />

Ex d IIC T5 (–50 � Ta � 80 °C)<br />

1180<br />

Vmax = 42.4 Vdc<br />

Special Conditions for Safe Use (X):<br />

This device contains a thin wall diaphragm. Installation,<br />

maintenance, <strong>and</strong> use shall take into account the<br />

environmental conditions to which the diaphragm will be<br />

subjected. The manufacturer’s instructions for installation<br />

<strong>and</strong> maintenance shall be followed in detail to assure safety<br />

during its expected lifetime.<br />

The Ex d blanking elements, cable gl<strong>and</strong>s, <strong>and</strong> wiring shall<br />

be suitable for a temperature of 90 °C.<br />

In case of repair, contact the manufacturer for information on<br />

the dimensions of the flameproof joints.<br />

N7 IECEx Type n<br />

Certification No. IECExBAS08.0046X II 3 G<br />

Ex nAnL IIC T4 (–40 � Ta � +70 °C)<br />

Ui = 42.4 Vdc max<br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing a 500<br />

V r.m.s. test to case. This must be taken into account on any<br />

installation in which it is used, for example by assuring that<br />

the supply to the apparatus is galvanically isolated.<br />

TIIS Certifications<br />

E4 TIIS Flame-Proof<br />

Ex d IIC T6<br />

TC18872 Coplanar with Display<br />

TC18873 Coplanar no display


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Inmetro Certifications<br />

E2 Flame-Proof<br />

Certificate No. CEPEL EX-1767/09X<br />

BR-Ex d IIC T6/T5<br />

I2 Intrinsic Safety<br />

Certificate No. CEPEL EX-1768/09X<br />

BR-Ex ia IIC T4<br />

Table 70. Input Parameters<br />

U i = 30 V<br />

I i = 200 mA<br />

P i = 1.0 W<br />

C i = 0.012 µF<br />

L i = 10 µH<br />

Table 71. RTD Assembly (2051CFx Option T or R)<br />

Ui = 5 Vdc<br />

Ii = 500 mA<br />

Pi = 0.63 W<br />

Special Conditions for Safe Use (X):<br />

When the optional transient protection terminal block is<br />

installed, the apparatus is not capable of withst<strong>and</strong>ing the<br />

500 V insulation test required by Clause 6.3.12 of<br />

IEC60079-11. This must be taken into account when<br />

installing the apparatus.<br />

GOST - Russia Certifications<br />

IM Intrinsic Safety<br />

Consult factory for availability<br />

EM Flame-Proof<br />

Consult factory for availability<br />

China (NEPSI) Certifications<br />

NOTE<br />

Refer to Appendix B of the 3051S Reference Manual (document<br />

number 00809-0100-4801) for Special Conditions for Safe Use.<br />

E3 Flame-Proof<br />

Certificate No.: GYJ081230<br />

Ex d IIC T5/T6<br />

I3 Intrinsic Safety<br />

Certificate No.: GYJ081231X<br />

Ex ia IIC T4<br />

Table 72. Input Parameters<br />

U i = 30 V<br />

I i = 200 mA<br />

P i = 1.0 W<br />

C i = 0.012 µF<br />

L i = 10 µH<br />

CCoE Certifications<br />

IW Intrinsic Safety<br />

Ex ia IIC T4<br />

EW Flame-Proof<br />

Ex d IIC T5 or T6<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Combinations of Certifications<br />

Stainless steel certification tag is provided when optional approval<br />

is specified. Once a device labeled with multiple approval types is<br />

installed, it should not be reinstalled using any other approval<br />

types. Permanently mark the approval label to distinguish it from<br />

unused approval types.<br />

K1 E1, I1, N1, <strong>and</strong> ND combination<br />

K4 E4 <strong>and</strong> I4 combination<br />

K5 E5 <strong>and</strong> I5 combination<br />

K6 I6 <strong>and</strong> E6 combination<br />

K7 E7, I7, <strong>and</strong> N7 combination<br />

KA E1, I1, E6, <strong>and</strong> I6 combination<br />

KB E5, I5, E6, <strong>and</strong> I6 combination<br />

KC E1, I1, E5, <strong>and</strong> I5 combination<br />

KD E1, I1, E5, I5, E6, <strong>and</strong> I6 combination<br />

113


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

114<br />

Dimensional Drawings<br />

Figure 2. <strong>Rosemount</strong> 3051S ERS Measurement Transmitter (Measurement in inches (millimeters))<br />

5.21 (132)<br />

4.55 (116)<br />

<strong>Rosemount</strong> 3051S ERS Measurement Transmitter - Coplanar Style<br />

<strong>Rosemount</strong> 3051S ERS Measurement Transmitter - In-Line Style<br />

4.20 (107)<br />

8.22<br />

(209)<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

3.45 (88)


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 3. <strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with FF <strong>Seal</strong> (Measurement in inches (millimeters))<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with FF (1)(2) - Coplanar Style<br />

+ Direct Mount<br />

Extension Length<br />

(1) FF (FFW) seal dimensions <strong>and</strong> pressure ratings can be found on page 125.<br />

(2) Lower housing (flushing ring) is available with FFW style flange.<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with FF (1)(2) - In-Line Style<br />

115


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 4. <strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with EF <strong>Seal</strong> (Measurement in inches (millimeters))<br />

116<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with EF (1) - Coplanar Style<br />

+ Direct Mount<br />

Extension Length<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with EF (1) - In-Line Style<br />

(1) EF (EFW) seal dimensions <strong>and</strong> pressure ratings can be found on page 131.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 5. <strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with RF <strong>Seal</strong> (Measurement in inches (millimeters))<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with RF (1) - Coplanar Style<br />

+ Direct Mount<br />

Extension Length<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with RF (1) - In-Line Style<br />

(1) RF (RFW) seal dimensions <strong>and</strong> pressure ratings can be found on page 127.<br />

117


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 6. <strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with RT <strong>Seal</strong> (Measurement in inches (millimeters))<br />

118<br />

(1) RT (RTW) seal dimensions can be found on page 138.<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with RT (1) - Coplanar Style<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with RT (1) - In-Line Style<br />

116<br />

+ Direct Mount<br />

Extension Length<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 7. <strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with SS <strong>Seal</strong> (Measurement in inches (millimeters))<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with SS (1) - Coplanar Style<br />

+ Direct Mount<br />

Extension Length<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with SS (1) - In-Line Style<br />

(1) SS (SSW) seal dimensions <strong>and</strong> pressure ratings can be found on page 128.<br />

119


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 8. <strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with SC <strong>Seal</strong> (Measurement in inches (millimeters))<br />

120<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with SC (1) - Coplanar Style<br />

+ Direct Mount<br />

Extension Length<br />

<strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter with SC (1) - In-Line Style<br />

(1) SC (SCW) seal dimensions <strong>and</strong> pressure ratings can be found on page 139.<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 9. Wireless Antenna on a Wireless PlantWeb Housing (1)(2) with FF <strong>Seal</strong> (Measurement in inches (millimeters))<br />

(1) Wireless 3051SAL_C transmitters require wireless transmitter output (option code X), the wireless PlantWeb housing (option codes 5A, 5B), an external<br />

antenna option (option codes WK, WM), as well as a SmartPower supply (option code 1).<br />

(2) Antenna rotation <strong>and</strong> dimensions are equal for both Inline <strong>and</strong> Coplanar styles of transmitters.<br />

121


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 10. <strong>Rosemount</strong> 3051L <strong>Level</strong> Transmitter with FF or EF <strong>Seal</strong> (Measurement in inches (millimeters)) (1)<br />

122<br />

“A”<br />

(1) FF (FFW) <strong>and</strong> EF (EFW) seal <strong>and</strong> flange diameter dimensions can be viewed on page 125 <strong>and</strong> page 131.<br />

Transmitter Direct Mount Extension<br />

Flange Rating Transmitter Flange Extension Extension Dimension (“A”)<br />

ANSI/ASME B16.5 Class 600 2-in. 7.65 in. (194,3 mm)<br />

All others 0-in. 5.65 in. (143,5 mm)<br />

Figure 11. <strong>Rosemount</strong> 2051L <strong>Level</strong> Transmitter with FF or EF <strong>Seal</strong> (Measurement in inches (millimeters)) (1)<br />

(1) FF (FFW) <strong>and</strong> EF (EFW) seal <strong>and</strong> flange diameter dimensions can be viewed on page 125 <strong>and</strong> page 131.<br />

,<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 12. Tuned System Assembly (Measurement in inches (millimeters))<br />

Tuned System Assembly (1)(2) shown with <strong>Rosemount</strong> 3051S Scalable <strong>Level</strong> Transmitter<br />

(116)<br />

(1) Tuned System Assemblies require specification of capillary length <strong>and</strong> addition <strong>1199</strong> Remote <strong>Seal</strong>.<br />

(2) Tuned System Assemblies are available on all <strong>Level</strong> <strong>Transmitters</strong>.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

<strong>Rosemount</strong> <strong>1199</strong> Remote <strong>Seal</strong> System Assembly shown with <strong>Rosemount</strong> 3051S Scalable Transmitter<br />

Capillary Connects<br />

to <strong>1199</strong> Remote <strong>Seal</strong>s<br />

(116)<br />

123


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 13. Thermal Optimizer (D5) with FFW (Measurement in inches (millimeters))<br />

124<br />

(116)<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 14. FFW Flush Flanged <strong>Seal</strong> - Two-Piece Design (shown with flushing ring)<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 73. Dimensional Table for FFW Flush Flanged Raised Face <strong>Seal</strong>s Two Piece (Upper Housing <strong>and</strong> Flange) Design (1)<br />

ANSI/ ASME<br />

EN1092-1<br />

JIS<br />

Pipe Size Class Flange<br />

Diameter<br />

“A”<br />

Flange<br />

Thickness<br />

“B”<br />

Bolt<br />

Circle<br />

“C”<br />

# of Bolts Bolt Hole<br />

Diameter<br />

“D”<br />

St<strong>and</strong>ard<br />

Diaphragm<br />

Diameter<br />

“F”<br />

Raised Face<br />

Outer<br />

Diameter<br />

“G”<br />

2-in. 150 lb. 6.00 (152) 0.69 (18) 4.75 (121) 4 0.75 (19) 2.30 (58) 3.62 (92)<br />

300 lb. 6.50 (165) 0.81 (21) 5.00 (127) 8 0.75 (19) 2.30 (58) 3.62 (92)<br />

600 lb. 6.50 (165) 1.00 (25) 5.00 (127) 8 0.75 (19) 2.30 (58) 3.62 (92)<br />

3-in. 150 lb. 7.50 (191) 0.88 (22) 6.00 (152) 4 0.75 (19) 3.50 (89) 5.00 (127)<br />

300 lb. 8.25 (210) 1.06 (27) 6.62 (168) 8 0.88 (22) 3.50 (89) 5.00 (127)<br />

600 lb. 8.25 (210) 1.25 (32) 6.62 (168) 8 0.88 (22) 3.50 (89) 5.00 (127)<br />

4-in. 150 lb. 9.00 (229) 0.88 (22) 7.50 (191) 8 0.75 (19) 3.50 (89) 6.20 (157)<br />

300 lb. 10.0 (254) 1.19 (30) 7.88 (200) 8 0.88 (22) 3.50 (89) 6.20 (157)<br />

600 lb. 10.75 (273) 1.50 (38) 8.50 (216) 8 1.00 (25) 3.50 (89) 6.20 (157)<br />

DN 50 PN 40 6.50 (165) 0.79 (20) 4.92 (125) 4 0.71 (18) 2.30 (58) 4.00 (102)<br />

PN 63 7.09 (180) 1.02 (26) 5.31 (135) 4 0.87 (22) 2.30 (58) 4.00 (102)<br />

PN 100 7.68 (195) 1.10 (28) 5.71 (145) 4 1.02 (26) 2.30 (58) 4.00 (102)<br />

DN 80 PN 40 7.87 (200) 0.94 (24) 6.30 (160) 8 0.71 (18) 3.50 (89) 5.43 (138)<br />

PN 63 8.46 (215) 1.10 (28) 6.69 (170) 8 0.88 (22) 3.50 (89) 5.43 (138)<br />

PN 100 9.06 (230) 1.26 (32) 7.09 (180) 8 1.02 (26) 3.50 (89) 5.43 (138)<br />

DN 100 PN 16 8.66 (220) 0.79 (20) 7.09 (180) 8 0.71 (18) 3.50 (89) 6.20 (157)<br />

PN 40 9.25 (235) 0.94 (24) 7.48 (190) 8 0.87 (22) 3.50 (89) 6.20 (157)<br />

PN 63 9.84 (250) 1.18 (30) 7.87 (200) 8 1.02 (26) 3.50 (89) 6.20 (157)<br />

50A 10K 6.10 (155) 0.63 (16) 4.72 (120) 4 0.75 (19) 2.30 (58) 3.62 (92)<br />

20K 6.10 (155) 0.71 (18) 4.72 (120) 8 0.75 (19) 2.30 (58) 3.62 (92)<br />

40K 6.50 (165) 1.02 (26) 5.12 (130) 8 0.75 (19) 2.30 (58) 4.00 (102)<br />

80A 10K 7.28 (185) 0.71 (18) 5.91 (150) 8 0.75 (19) 3.50 (89) 5.00 (127)<br />

20K 7.87 (200) 0.87 (22) 6.30 (160) 8 0.91 (23) 3.50 (89) 5.00 (127)<br />

40K 8.27 (210) 1.26 (32) 6.69 (170) 8 0.91 (23) 3.50 (89) 5.43 (138)<br />

100A 10K 8.27 (210) 0.71 (18) 6.89 (175) 8 0.75 (19) 3.50 (89) 6.20 (157)<br />

20K 8.86 (225) 0.95 (24) 7.28 (185) 8 0.91 (23) 3.50 (89) 6.20 (157)<br />

40K 9.84 (250) 1.42 (36) 8.07 (205) 8 0.98 (25) 3.50 (89) 6.20 (157)<br />

(1) Dimensions are in inches (millimeters).<br />

125


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

126<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 57. Dimensional Table for FFW Flush Flanged Raised Face <strong>Seal</strong>s Two Piece (Upper Housing <strong>and</strong> Flange) Design (1)<br />

ANSI / ASME<br />

EN1092-1<br />

JIS<br />

Pipe Size INNER DIAMETER<br />

“K”<br />

BEVELED EDGE “L” THICKNESS WITH<br />

1 /4-NPT F.C. “M”<br />

THICKNESS WITH<br />

1 /2-NPT F.C. “M”<br />

MINIMUM GASKET<br />

I.D. “N”<br />

2-in. 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

3-in. 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

4-in. 3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

DN 50 2.40 (61) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

2.40 (61) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

2.40 (61) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

DN 80 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

DN 100 3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

50A 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

2.40 (61) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

80A 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

100A 3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

3.60 (91) — 0.97 (25) 1.30 (33) 4.50 (113)<br />

(1) Dimensions are in inches (millimeters).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 15. FFW Flush Flanged <strong>Seal</strong> - One-Piece Design (shown with flushing ring)<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Table 58. Dimensional Table for FFW Flush Flanged <strong>Seal</strong>s One Piece (Upper Housing <strong>and</strong> Flange) Design (Option code E) (1)<br />

ANSI / ASME<br />

EN1092-1<br />

JIS<br />

Pipe Size Class Flange<br />

Diameter<br />

“A”<br />

Flange<br />

Thickness<br />

“B”<br />

Bolt<br />

Circle<br />

“C”<br />

# of<br />

Bolts<br />

Bolt Hole<br />

Diameter<br />

“D”<br />

St<strong>and</strong>ard<br />

Diaphragm<br />

Diameter<br />

“F”<br />

Raised<br />

Face<br />

Diameter<br />

“G”<br />

Raised<br />

Face<br />

Height<br />

“J”<br />

MINIMUM<br />

GASKET<br />

I.D. “N”<br />

2-in. 150 lb. 6.00 (152) 0.69 (18) 4.75 (121) 4 0.75 (19) 2.30 (58) 3.62 (92) 0.06 (1.5) 2.62 (67)<br />

300 lb. 6.50 (165) 0.81 (21) 5.00 (127) 8 0.75 (19) 2.30 (58) 3.62 (92) 0.06 (1.5) 2.62 (67)<br />

600 lb. 6.50 (165) 1.00 (25) 5.00 (127) 8 0.75 (19) 2.30 (58) 3.62 (92) 0.25 (6.4) 2.62 (67)<br />

3-in. 150 lb. 7.50 (191) 0.88 (22) 6.00 (152) 4 0.75 (19) 3.50 (89) 5.00 (127) 0.06 (1.5) 3.82 (97)<br />

300 lb. 8.25 (210) 1.06 (27) 6.62 (168) 8 0.88 (22) 3.50 (89) 5.00 (127) 0.06 (1.5) 3.82 (97)<br />

600 lb. 8.25 (210) 1.25 (32) 6.62 (168) 8 0.88 (22) 3.50 (89) 5.00 (127) 0.25 (6.4) 3.82 (97)<br />

4-in. 150 lb. 9.00 (229) 0.88 (22) 7.50 (191) 8 0.75 (19) 3.50 (89) 6.20 (157) 0.06 (1.5) 4.50 (114)<br />

300 lb. 10.00 (254) 1.19 (30) 7.88 (200) 8 0.88 (22) 3.50 (89) 6.20 (157) 0.06 (1.5) 4.50 (114)<br />

600 lb. 10.75 (273) 1.50 (38) 8.50 (216) 8 1.00 (25) 3.50 (89) 6.20 (157) 0.25 (6.4) 4.50 (114)<br />

DN 50 PN 40 6.50 (165) 0.67 (17) 4.92 (125) 4 0.71 (18) 2.30 (58) 4.00 (102) 0.12 (3.0) 2.62 (67)<br />

PN 63 7.08 (180) 0.91 (23) 5.31 (135) 4 0.87 (22) 2.30 (58) 4.00 (102) 0.12 (3.0) 2.62 (67)<br />

PN 100 7.68 (195) 0.99 (25) 5.71 (145) 4 1.02 (26) 2.30 (58) 4.00 (102) 0.12 (3.0) 2.62 (67)<br />

DN 80 PN 40 7.87 (200) 0.83 (21) 6.30 (160) 8 0.71 (18) 3.50 (89) 5.43 (138) 0.12 (3.0) 3.82 (97)<br />

PN 63 8.46 (215) 0.99 (25) 6.69 (170) 8 0.88 (22) 3.50 (89) 5.43 (138) 0.12 (3.0) 3.82 (97)<br />

PN 100 9.06 (230) 1.15 (29) 7.09 (180) 8 1.02 (26) 3.50 (89) 5.43 (138) 0.12 (3.0) 3.82 (97)<br />

DN 100 PN 16 8.66 (220) 0.67 (17) 7.09 (180) 8 0.71 (18) 3.50 (89) 6.20 (157) 0.12 (3.0) 4.50 (114)<br />

PN 40 9.25 (235) 0.83 (21) 7.48 (190) 8 0.87 (22) 3.50 (89) 6.20 (157) 0.12 (3.0) 4.50 (114)<br />

PN 63 9.84 (250) 1.07 (27) 7.87 (200) 8 1.02 (26) 3.50 (89) 6.20 (157) 0.12 (3.0) 4.50 (114)<br />

50A 10K 6.10 (155) 0.63 (16) 4.72 (120) 4 0.75 (19) 2.30 (58) 3.62 (92) 0.08 (2.0) 2.62 (67)<br />

20K 6.10 (155) 0.71 (18) 4.72 (120) 8 0.75 (19) 2.30 (58) 3.62 (92) 0.08 (2.0) 2.62 (67)<br />

40K 6.50 (165) 1.02 (26) 5.12 (130) 8 0.75 (19) 2.30 (58) 3.62 (92) 0.08 (2.0) 2.62 (67)<br />

80A 10K 7.28 (185) 0.71 (18) 5.91 (150) 8 0.75 (19) 3.50 (89) 5.00 (127) 0.08 (2.0) 3.82 (97)<br />

20K 7.87 (200) 0.87 (22) 6.30 (160) 8 0.91 (23) 3.50 (89) 5.00 (127) 0.08 (2.0) 3.82 (97)<br />

40K 8.27 (210) 1.26 (32) 6.69 (170) 8 0.91 (23) 3.50 (89) 5.00 (127) 0.08 (2.0) 3.82 (97)<br />

100A 10K 8.27 (210) 0.71 (18) 6.89 (175) 8 0.75 (19) 3.50 (89) 6.20 (157) 0.08 (2.0) 4.50 (114)<br />

20K 8.86 (225) 0.95 (24) 7.28 (185) 8 0.91 (23) 3.50 (89) 6.20 (157) 0.08 (2.0) 4.50 (114)<br />

40K 9.84 (250) 1.42 (36) 8.07 (205) 8 0.98 (25) 3.50 (89) 6.20 (157) 0.08 (2.0) 4.50 (114)<br />

(1) Dimensions are in inches (millimeters).<br />

127


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 16. FFW Flush Flanged <strong>Seal</strong> - Flushing Connection Ring (Lower Housing)<br />

Table 1. Dimensional Table for FFW Flushing Connection Ring (Lower Housing) (1)<br />

ANSI / ASME<br />

EN1092-1<br />

JIS<br />

128<br />

Pipe Size Raised Face<br />

Diameter “G”<br />

2-in.<br />

3-in.<br />

4-in.<br />

DN 50<br />

DN 80<br />

DN 100<br />

(1) Dimensions are in inches (millimeters).<br />

K<br />

L<br />

G<br />

Inner Diameter “K” Beveled Edge “L” Thickness with<br />

1 /4–NPT F.C. “M”<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Thickness with<br />

1 /2–NPT F.C. “M”<br />

3.62 (92) 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33)<br />

3.62 (92) 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33)<br />

3.62 (92) 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

4.00 (102) 2.40 (61) — 0.97 (25) 1.30 (33)<br />

4.00 (102) 2.40 (61) — 0.97 (25) 1.30 (33)<br />

4.00 (102) 2.40 (61) — 0.97 (25) 1.30 (33)<br />

5.43 (138) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

5.43 (138) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

5.43 (138) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

50A 3.62 (92) 2.12 (54) — 0.97 (25) 1.30 (33)<br />

3.62 (92) 2.12 (54) — 0.97 (25) 1.30 (33)<br />

3.62 (92) 2.12 (54) — 0.97 (25) 1.30 (33)<br />

80A 5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

100A 6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

6.20 (157) 3.60 (91) — 0.97 (25) 1.30 (33)<br />

Dimensions are in inches (millimeters)<br />

M


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 17. RFW Flanged <strong>Seal</strong> St<strong>and</strong>ard Design<br />

Table 2. RFW Flanged <strong>Seal</strong> St<strong>and</strong>ard Design Dimensions (1)(2)<br />

ANSI / ASME<br />

EN 1092-1<br />

JIS<br />

Pipe Size Class Flange<br />

Diameter<br />

“A”<br />

Flange<br />

Thickness<br />

“B”<br />

(1) Dimensions are in inches (millimeters).<br />

(2) Lower housing is loose on st<strong>and</strong>ard design, consult factory for retained lower housing options.<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Overall Height “C” Bolt Circle<br />

Diameter<br />

“D”<br />

No or 1 /4-in.<br />

NPT flush<br />

connection<br />

1 /2-in. NPT<br />

flush<br />

connection<br />

Bolt Hole<br />

Diameter<br />

“E”<br />

Lower<br />

Housing<br />

Diameter “F”<br />

1<br />

/2-in. 2500 lb. 5.25 (133) 1.19 (30) 2.45 (62) 2.79 (71) 3.50 (89) 0.88 (22) 2.62 (67)<br />

3<br />

/4-in. 300/600 lb. 4.62 (117) 0.62 (16) 2.45 (62) 2.79 (71) 3.25 (83) 0.75 (19) 2.62 (67)<br />

1-in. 150 lb. 4.25 (108) 0.50 (13) 2.45 (62) 2.79 (71) 3.12 (79) 0.63 (16) 2.62 (67)<br />

300 lb. 4.88 (124) 0.62 (16) 2.45 (62) 2.79 (71) 3.50 (89) 0.75 (19) 2.62 (67)<br />

600 lb. 4.88 (124) 0.69 (18) 2.45 (62) 2.79 (71) 3.50 (89) 0.75 (19) 2.62 (67)<br />

1 1 /2-in. 150 lb. 5.00 (127) 0.62 (16) 2.45 (62) 2.79 (71) 3.88 (99) 0.63 (16) 2.88 (73)<br />

300 lb. 6.12 (155) 0.75 (19) 2.45 (62) 2.79 (71) 4.50 (114) 0.88 (22) 2.88 (73)<br />

600 lb. 6.12 (155) 0.88 (22) 2.45 (62) 2.79 (71) 4.50 (114) 0.88 (22) 2.88 (73)<br />

DN 25 PN 40 4.53 (115) 0.71 (18) 2.45 (62) 2.79 (71) 3.35 (85) 0.55 (14) 2.68 (68)<br />

DN 40 PN 40 5.91 (150) 0.71 (18) 2.45 (62) 2.79 (71) 4.33 (110) 0.71 (18) 3.47 (88)<br />

20A 40K 4.72 (120) 0.79 (20) 2.45 (62) 2.79 (71) 3.35 (85) 0.75 (19) 2.62 (67)<br />

25A 10K 4.92 (125) 0.55 (14) 2.45 (62) 2.79 (71) 3.54 (90) 0.75 (19) 2.62 (67)<br />

20K 4.92 (125) 0.63 (16) 2.45 (62) 2.79 (71) 3.54 (90) 0.75 (19) 2.62 (67)<br />

40K 5.12 (130) 0.87 (22) 2.45 (62) 2.79 (71) 3.74 (95) 0.75 (19) 2.76 (70)<br />

40A 10K 5.51 (140) 0.63 (16) 2.45 (62) 2.79 (71) 4.13 (105) 0.75 (19) 3.19 (81)<br />

20K 5.51 (140) 0.71 (18) 2.45 (62) 2.79 (71) 4.13 (105) 0.75 (19) 3.19 (81)<br />

40K 6.30 (160) 0.94 (24) 2.45 (62) 2.79 (71) 4.72 (120) 0.91 (23) 3.54 (90)<br />

129


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 18. RFW Flanged <strong>Seal</strong> Stud Bolt Design<br />

Table 3. RFW Flanged <strong>Seal</strong> Stud Bolt Design Dimensions (1)<br />

ANSI / ASME<br />

EN 1092-1<br />

JIS<br />

130<br />

Pipe Size Class Overall Height “A” Stud Circle<br />

Diameter “B”<br />

No or 1 /4-in.<br />

NPT flush<br />

connection<br />

1 /2-in. NPT<br />

flush<br />

connection<br />

(1) Upper <strong>and</strong> lower housing installed bolt torque with CS or SST bolts is 23 ft-lbs. (31 Nm).<br />

Stud (Size,<br />

Length) “C”<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Lower Housing<br />

Diameter “D”<br />

Raised Face<br />

Diameter “E”<br />

1 /2-in. 150 lb. 2.52 (64) 2.82 (72) 2.38 (61) 1 /2-13NC, 2.5-in. 3.74 (95) 1.38 (35)<br />

1 /2-in. 300/600 lb. 2.77 (70) 2.87 (73) 2.62 (67) 1 /2-13NC, 2.5-in. 3.75 (95) 1.38 (35)<br />

3<br />

/4-in. 150 lb. 2.52 (64) 2.82 (72) 2.75 (70)<br />

1<br />

/2-13NC, 2.5-in. 3.88 (99) 1.69 (43)<br />

DN 15 PN 40 2.52 (64) 2.82 (72) 2.56 (65) M12x1.75, 60mm 3.74 (95) 1.77 (45)<br />

DN 15 PN 100/160 2.52 (64) 2.82 (72) 2.95 (75) M12x1.75, 60mm 4.13 (105) 1.77 (45)<br />

DN 20 PN 40 2.52 (64) 2.82 (72) 2.95 (75) M12x1.75, 60mm 4.13 (105) 2.28 (58)<br />

10A 10K 2.52 (64) 2.82 (72) 2.56 (65) M12x1.75,60mm 3.74 (95) 1.81 (46)<br />

20K 2.52 (64) 2.82 (72) 2.56 (65) M12x1.75,60mm 3.74 (95) 1.81 (46)<br />

40K 2.52 (64) 2.82 (72) 2.95 (75) M16x2.00,70mm 4.33 (110) 2.05 (52)<br />

15A 10K 2.52 (64) 2.82 (72) 2.76 (70) M12x1.75,60mm 3.74 (95) 2.01 (51)<br />

20K 2.52 (64) 2.82 (72) 2.76 (70) M12x2.00,60mm 3.74 (95) 2.01 (51)<br />

40K 2.52 (64) 2.82 (72) 3.15 (80) M16x2.00,70mm 4.53 (115) 2.17 (55)<br />

20A 10K 2.52 (64) 2.82 (72) 2.95 (75) M12x1.75,60mm 3.94 (100) 2.21 (56)<br />

20K 2.52 (64) 2.82 (72) 2.95 (75) M12x1.75,60mm 3.94 (100) 2.21 (56)


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 19. EFW Extended Flanged <strong>Seal</strong> - Extended Flanged Assembly<br />

Table 4. EFW Extended Flanged <strong>Seal</strong> Dimensions (1)<br />

ANSI / ASME<br />

EN 1092-1<br />

JIS<br />

Pipe Size Class Flange Diameter “A” Flange Thickness<br />

“B”<br />

(1) Dimensions are in inches (millimeters).<br />

Bolt Circle “C” # of<br />

Bolts<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Bolt Hole<br />

Diameter “D”<br />

Raised Face<br />

Diameter “F”<br />

11 150 lb. 5.00 (127) 0.62 (16) 3.88 (99) 4 0.63 (16) 2.88 (73)<br />

/2-in. 300 lb. 6.12 (156) 0.75 (19) 4.50 (114) 4 0.88 (22) 2.88 (73)<br />

600 lb. 6.12 (156) 0.88 (22) 4.50 (114) 4 0.88 (22) 2.88 (73)<br />

150 lb. 6.00 (152) 0.69 (18) 4.75 (121) 4 0.75 (19) 3.62 (92)<br />

2-in. 300 lb. 6.50 (165) 0.82 (21) 5.00 (127) 8 0.75 (19) 3.62 (92)<br />

600 lb. 6.50 (165) 1.00 (25) 5.00 (127) 8 0.75 (19) 3.62 (92)<br />

150 lb. 7.50 (191) 0.88 (22) 6.00 (152) 4 0.75 (19) 5.00 (127)<br />

3-in. 300 lb. 8.25 (210) 1.06 (27) 6.62 (168) 8 0.88 (22) 5.00 (127)<br />

600 lb. 8.25 (210) 1.25 (32) 6.62 (168) 8 0.88 (22) 5.00 (127)<br />

150 lb. 9.00 (229) 0.88 (22) 7.50 (191) 8 0.75 (19) 6.20 (158)<br />

4-in. 300 lb. 10.00 (254) 1.19 (30) 7.88 (200) 8 0.88 (22) 6.20 (158)<br />

600 lb. 10.75 (273) 1.50 (38) 8.50 (216) 8 1.00 (25) 6.20 (158)<br />

PN 40 6.50 (165) 0.79 (20) 4.92 (125) 4 0.71 (18) 4.02 (102)<br />

DN 50 PN 63 7.08 (180) 1.02 (26) 5.31 (135) 4 0.87 (22) 4.02 (102)<br />

PN 100 7.68 (195) 1.10 (28) 5.71 (145) 4 1.02 (26) 4.02 (102)<br />

PN 40 7.87 (200) 0.94 (24) 6.30 (160) 8 0.71 (18) 5.43 (138)<br />

DN 80 PN 63 8.46 (215) 1.10 (28) 6.69 (170) 8 0.88 (22) 5.43 (138)<br />

PN 100 9.06 (230) 1.26 (32) 7.09 (180) 8 1.02 (26) 5.43 (138)<br />

PN 16 8.66 (220) 0.79 (20) 7.09 (180) 8 0.71 (18) 6.20 (158)<br />

DN 100 PN 40 9.25 (235) 0.94 (24) 7.48 (190) 8 0.87 (22) 6.20 (158)<br />

PN 63 9.84 (250) 1.18 (30) 7.87 (200) 8 1.02 (26) 6.20 (158)<br />

50A 10K 6.10 (155) 0.63 (16) 4.72 (120) 4 0.75 (19) 3.62 (92)<br />

20K 6.10 (155) 0.71 (18) 4.72 (120) 8 0.75 (19) 3.62 (92)<br />

40K 6.50 (165) 1.02 (26) 5.12 (130) 8 0.75 (19) 4.00 (102)<br />

80A 10K 7.28 (185) 0.71 (18) 5.91 (150) 8 0.75 (19) 5.00 (127)<br />

20K 7.87 (200) 0.87 (22) 6.30 (160) 8 0.91 (23) 5.00 (127)<br />

40K 8.27 (210) 1.26 (32) 6.69 (170) 8 0.91 (23) 5.43 (138)<br />

100A 10K 8.27 (210) 0.71 (18) 6.89 (175) 8 0.75 (19) 6.20 (158)<br />

20K 8.86 (225) 0.94 (24) 7.28 (185) 8 0.91 (23) 6.20 (158)<br />

40K 9.84 (250) 1.42 (36) 8.07 (205) 8 0.98 (25) 6.20 (158)<br />

131


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

132<br />

Process Connection Size (1) Diameter “E”<br />

ANSI B16.5 EN 1092-1 JIS B2238<br />

3-in. DN 80 80A 2.58 (66)<br />

4-in. DN 100 100A 3.50 (89)<br />

1 ½-in. DN 40 40A 1.45 (37)<br />

2-in. DN 50 50A 1.90 (48)<br />

3-in. Headbox DN 80 Headbox — 2.88 (73)<br />

4-in. Headbox DN100 Headbox — 3.78 (96)<br />

(1) Dimensions are in inches (millimeters).<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 20. PFW Pancake <strong>Seal</strong><br />

Table 5. PFW Pancake <strong>Seal</strong> Dimensions (1)<br />

ANSI / ASME<br />

EN1092-1<br />

Pipe<br />

Size Class<br />

(1) Dimensions are in inches (millimeters).<br />

Flange Diameter<br />

“A”<br />

Flange Thickness<br />

“B”<br />

# of<br />

Bolts<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Bolt Circle<br />

“C”<br />

Bolt Hole<br />

Diameter “D”<br />

St<strong>and</strong>ard<br />

Diaphragm<br />

Diameter “F”<br />

2-in. 150 lb. 6.00 (152) 0.69 (18) 4 4.75 (121) 0.75 (19) 2.30 (58)<br />

300 lb. 6.50 (165) 0.81 (21) 8 5.00 (127) 0.75 (19) 2.30 (58)<br />

600 lb. 6.50 (165) 1.00 (25) 8 5.00 (127) 0.75 (19) 2.30 (58)<br />

900/1500 lb. 8.50 (216) 1.50 (38) 8 6.50 (165) 1.00 (25) 2.30 (58)<br />

2500 lb. 9.25 (235) 2.00 (51) 8 6.75 (172) 1.13 (29) 2.30 (58)<br />

3-in. 150 lb. 7.50 (191) 0.88 (22) 4 6.00 (152) 0.75 (19) 3.50 (89)<br />

300 lb. 8.25 (210) 1.06 (27) 8 6.62 (168) 0.88 (22) 3.50 (89)<br />

600 lb. 8.25 (210) 1.25 (32) 8 6.62 (168) 0.88 (22) 3.50 (89)<br />

900 lb. 10.50 (267) 1.50 (38) 8 8.00 (203) 1.25 (32) 3.50 (89)<br />

1500 lb. 10.50 (267) 1.88 (48) 8 8.00 (203) 1.25 (32) 3.50 (89)<br />

2500 lb 12.00 (305) 2.62 (67) 8 9.00 (229) 1.38 (35) 3.50 (89)<br />

DN 50 PN 40 6.50 (165) 0.67 (17) 4 4.92 (125) 0.71 (18) 2.30 (58)<br />

PN 63 7.09 (180) 0.91 (23) 4 5.31 (135) 0.87 (22) 2.30 (58)<br />

PN 100 7.68 (195) 0.98 (25) 4 5.71 (145) 1.10 (28) 2.30 (58)<br />

DN 80 PN 40 7.87 (200) 0.83 (21) 8 6.30 (160) 0.71 (18) 3.50 (89)<br />

PN 63 8.46 (215) 0.98 (25) 8 6.69 (170) 0.87 (22) 3.50 (89)<br />

PN 100 9.06 (230) 0.98 (25) 8 7.09 (180) 1.10 (28) 3.50 (89)<br />

133


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

ANSI / ASME<br />

EN1092-1<br />

134<br />

Pipe Size<br />

Outer Diameter<br />

“G”<br />

Inner<br />

Diameter<br />

“K”<br />

Beveled<br />

Diameter “L”<br />

Thickness<br />

with 1 /4-NPT<br />

F.C. “M”<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Thickness with<br />

1 /2-NPT F.C. “M” Minimum Gasket I.D. “N”<br />

2-in. 3.62 (92) 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

3.62 (92) 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

3.62 (92) 2.12 (54) 2.48 (63) 0.97 (25) 1.30 (33) 2.62 (67)<br />

3.62 (92) 2.12 (54) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

3.62 (92) 2.12 (54) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

3-in. 5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33) 2.82 (97)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33) 2.82 (97)<br />

5.00 (127) 3.60 (91) — 0.97 (25) 1.30 (33) 2.82 (97)<br />

DN 50 4.00 (102) 2.40 (61) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

4.00 (102) 2.40 (61) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

4.00 (102) 2.40 (61) — 0.97 (25) 1.30 (33) 2.62 (67)<br />

DN 80 5.43 (138) 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

5.43 (138) 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)<br />

5.43 (138) 3.60 (91) — 0.97 (25) 1.30 (33) 3.82 (97)


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 21. FCW Flush Flanged <strong>Seal</strong> – Ring Type Joint (RTJ) Gasket Surface Two-Piece Design (shown with flushing ring)<br />

Table 6. Dimensional Table for FCW 2-Piece Flange Type Flush Diaphragm <strong>Seal</strong> (1)<br />

ANSI / ASME<br />

ANSI / ASME<br />

Pipe Size Class Flange<br />

Diameter “A”<br />

Flange<br />

Thickness “B”<br />

Bolt Circle<br />

Diameter “C”<br />

Bolt Hole<br />

Diameter “D”<br />

Overall Height<br />

“H”<br />

Raised Face<br />

Height “J”<br />

2-in. 150 lb. 6.00 (152) 0.69 (18) 4.75 (121) 0.75 (19) 2.43 (62) 0.68 (17)<br />

300 lb. 6.50 (165) 0.82 (21) 5.00 (127) 0.75 (19) 2.43 (62) 0.68 (17)<br />

600 lb. 6.50 (165) 1.00 (25) 5.00 (127) 0.75 (19) 2.43 (62) 0.68 (17)<br />

1500 lb. 8.50 (216) 1.50 (38) 6.50 (165) 1.00 (25) 2.57 (65) 0.82 (21)<br />

2500 lb. 9.25 (235) 2.00 (51) 6.75 (171) 1.14 (29) 3.07 (78) 0.82 (21)<br />

3-in. 150 lb. 7.50 (191) 0.88 (22) 6.00 (152) 0.75 (19) 2.43 (62) 0.68 (17)<br />

300 lb. 8.25 (210) 1.06 (27) 6.62 (168) 0.88 (22) 2.43 (62) 0.68 (17)<br />

600 lb. 8.25 (210) 1.25 (32) 6.62 (168) 0.88 (22) 2.43 (62) 0.68 (17)<br />

900 lb. 9.50 (241) 1.50 (38) 7.50 (191) 1.00 (25) 2.57 (65) 0.82 (21)<br />

1500 lb. 10.50 (267) 1.88 (48) 8.00 (203) 1.25 (32) 3.07 (78) 0.82 (21)<br />

2500 lb. 12.00 (305) 2.62 (67) 9.00 (229) 1.38 (35) 4.07 (103) 0.82 (21)<br />

(1) Dimensions are in inches (millimeters).<br />

Pipe Size RTJ Diameter<br />

“E”<br />

Diaphragm<br />

Diameter “F”<br />

Raised Face<br />

Diameter “G”<br />

Inner Diameter<br />

“K”<br />

Thickness with<br />

1 /4-NPT F.C. “L”<br />

Thickness with<br />

1 /2-NPT F.C. “L”<br />

2-in. 3.25 (83) 2.30 (58) 4.00 (102) 2.12 (54) 1.40 (36) 1.70 (43)<br />

3.25 (83) 2.30 (58) 4.25 (108) 2.12 (54) 1.40 (36) 1.70 (43)<br />

3.25 (83) 2.30 (58) 4.25 (108) 2.12 (54) 1.40 (36) 1.70 (43)<br />

3.75 (95) 2.30 (58) 4.88 (124) 2.12 (54) 1.40 (36) 1.70 (43)<br />

4.00 (102) 3.50 (89) 5.25 (133) 2.12 (54) 1.40 (36) 1.70 (43)<br />

3-in. 4.50 (114) 3.50 (89) 5.25 (133) 3.60 (91) 1.50 (38) 1.80 (46)<br />

4.88 (124) 3.50 (89) 5.75 (146) 3.60 (91) 1.50 (38) 1.80 (46)<br />

4.88 (124) 3.50 (89) 5.75 (146) 3.60 (91) 1.50 (38) 1.80 (46)<br />

4.88 (124) 3.50 (89) 6.12 (155) 3.60 (91) 1.50 (38) 1.80 (46)<br />

5.38 (137) 3.50 (89) 6.62 (168) 3.60 (91) 1.50 (38) 1.80 (46)<br />

5.00 (127) 3.50 (89) 6.62 (168) 3.60 (91) 1.50 (38) 1.80 (46)<br />

135


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 22. RCW Flanged Remote <strong>Seal</strong> Ring Type Joint (RTJ) <strong>and</strong> Flushing Connection Ring<br />

Table 7. RCW Flanged Remote <strong>Seal</strong> Dimensions (1)<br />

ANSI / ASME<br />

136<br />

Flange<br />

Diameter<br />

“A”<br />

(1) Dimensions are in inches (millimeters).<br />

Flange<br />

Thickness<br />

“B”<br />

Bolt Circle<br />

Diameter<br />

“C”<br />

Bolt Hole<br />

Diameter<br />

“D”<br />

Lower<br />

Housing<br />

Inner<br />

Diameter<br />

“E”<br />

RTJ<br />

Groove<br />

Diameter<br />

“F”<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Lower<br />

Housing<br />

Outer<br />

Diameter<br />

“G”<br />

Pipe<br />

Overall Height<br />

Size Class<br />

“H”<br />

No or<br />

1<br />

/4-in. NPT<br />

1<br />

/2-in. NPT<br />

flush<br />

flush<br />

connection<br />

connection<br />

1<br />

/2-in. 2500 lb. 5.25 (133) 1.19 (30) 3.50 (89) 0.88 (22) 0.62 (16) 1.69 (43) 2.64 (67) 2.88 (73) 3.18 (81)<br />

3<br />

/4-in. 300/600 lb. 4.62 (117) 0.62 (16) 3.25 (83) 0.75 (19) 0.82 (21) 1.69 (43) 2.64 (67) 2.88 (73) 3.18 (81)<br />

3<br />

/4-in. 900/1500 lb. 5.12 (130) 1.00 (25) 3.50 (89) 0.88 (22) 0.82 (21) 1.75 (45) 2.64 (67) 2.88 (73) 3.18 (81)<br />

3<br />

/4-in. 2500 lb. 5.50 (140) 1.25 (32) 3.75 (95) 0.88 (22) 0.82 (21) 2.00 (51) 2.90 (74) 2.88 (73) 3.18 (81)<br />

1-in. 150 lb. 4.25 (108) 0.50 (13) 3.12 (79) 0.63 (16) 1.05 (27) 1.88 (48) 2.64 (67) 2.88 (73) 3.18 (81)<br />

1-in. 300 lb. 4.88 (124) 0.62 (16) 3.50 (89) 0.75 (19) 1.05 (27) 2.00 (51) 2.77 (70) 2.88 (73) 3.18 (81)<br />

1-in. 600 lb. 4.88 (124) 0.69 (18) 3.50 (89) 0.75 (19) 1.05 (27) 2.00 (51) 2.77 (70) 2.88 (73) 3.18 (81)<br />

1-in. 900/1500 lb. 5.88 (149) 1.12 (29) 4.00 (102) 1.00 (25) 1.05 (27) 2.00 (51) 2.83 (72) 2.88 (73) 3.18 (81)<br />

1-in. 2500 lb. 6.25 (159) 1.38 (35) 4.25 (108) 1.00 (25) 1.05 (27) 2.38 (60) 3.27 (83) 2.88 (73) 3.18 (81)<br />

1 1 /2-in. 150 lb. 5.00 (127) 0.62 (16) 3.88 (98) 0.63 (16) 1.61 (41) 2.56 (65) 3.27 (83) 2.88 (73) 3.18 (81)<br />

1 1 /2-in. 300 lb. 6.12 (156) 0.75 (19) 4.50 (114) 0.88 (22) 1.61 (41) 2.69 (68) 3.58 (91) 2.88 (73) 3.18 (81)<br />

1 1 /2-in. 600 lb. 6.12 (156) 0.88 (22) 4.50 (114) 0.88 (22) 1.61 (41) 2.69 (68) 3.58 (91) 2.88 (73) 3.18 (81)<br />

1 1 /2-in. 900/1500 lb. 7.00 (178) 1.25 (32) 4.88 (124) 1.12 (28) 1.61 (41) 2.69 (68) 3.64 (93) 2.88 (73) 3.18 (81)<br />

1 1 /2-in. 2500 lb. 8.00 (203) 1.75 (45) 5.75 (146) 1.25 (32) 1.61 (41) 3.25 (83) 4.52 (115) 2.88 (73) 3.18 (81)


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 23. FUW Flush Flanged Type <strong>Seal</strong> - EN1092-1 Type D<br />

Table 8. FUW Flush Flanged Type <strong>Seal</strong> Dimensions (1)<br />

EN 1092-1<br />

Pipe<br />

Size<br />

Class Flange<br />

Diameter<br />

“A”<br />

Flange<br />

Thickness<br />

“B”<br />

Bolt<br />

Circle<br />

“C”<br />

Bolt Hole<br />

Diameter<br />

“D”<br />

Figure 24. FVW Flush Flanged Type <strong>Seal</strong> - EN1092-1 Type C<br />

# of<br />

Bolts<br />

St<strong>and</strong>ard<br />

Diaphragm<br />

Diameter<br />

“F”<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Raised<br />

Face<br />

Diameter<br />

“G”<br />

Groove<br />

O.D.<br />

“J”<br />

Groove<br />

I.D.<br />

“K”<br />

Groove<br />

Depth<br />

“L”<br />

DN 50 PN 40 6.50 (165) 0.79 (20) 4.92 (125) 0.71 (18) 4 2.30 (58) 4.00 (102) 3.46 (88) 2.83 (72) 0.16 (4.0)<br />

DN 80 PN 40 7.87 (200) 0.94 (24) 6.30 (160) 0.71 (18) 8 3.50 (89) 5.43 (138) 4.76 (121) 4.13 (105) 0.16 (4.0)<br />

(1) Measurement in inches (millimeters).<br />

Table 9. FVW Flush Flanged Type <strong>Seal</strong> Dimensions (1)<br />

EN 1092-1<br />

Pipe<br />

Size<br />

Class Flange<br />

Diameter<br />

“A”<br />

Flange<br />

Thickness<br />

“B”<br />

Bolt Circle<br />

“C”<br />

Bolt Hole<br />

Diameter<br />

“D”<br />

# of<br />

Bolts<br />

St<strong>and</strong>ard<br />

Diaphragm<br />

Diameter “F”<br />

Groove<br />

O.D.<br />

“J”<br />

Tongue<br />

I.D.<br />

“K”<br />

Tongue<br />

Depth<br />

“L”<br />

DN 50 PN 40 6.50 (165) 0.79 (20) 4.92 (125) 0.71 (18) 4 2.30 (58) 3.43 (87) 2.87 (73) 0.18 (4.5)<br />

DN 80 PN 40 7.87 (200) 0.94 (24) 6.30 (160) 0.71 (18) 8 3.50 (89) 4.72 (120) 4.17 (106) 0.18 (4.5)<br />

(1) Measurement in inches (millimeters).<br />

137


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 25. RTW Threaded <strong>Seal</strong><br />

Table 10. RTW Threaded <strong>Seal</strong> Dimensions (1)<br />

Figure 26. HTS Male Threaded <strong>Seal</strong><br />

138<br />

(1) Dimensions are in inches (millimeters).<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Rating Overall Diameter 'A' Overall Height “B”<br />

No or 1 /4-in. NPT flush connection 1 /2-in. NPT flush connection<br />

2500 psi (173 bar) 3.74 (95) 2.47 (63) 2.82 (72)<br />

5000 psi (345 bar) 3.74 (95) 1.95 (50) 2.31 (59)<br />

10000 psi (690 bar) 4.00 (102) 1.95 (50) —<br />

Table 11. HTS Male Threaded <strong>Seal</strong> Dimensions (1)<br />

Process Type Connection Size Outer Diameter<br />

“A”<br />

Diaphragm Diameter “B” Length “C” Overall Height “D”<br />

ANSI NPT 1-in. NPT 2.03 (51.6) 1.09 (27.9) 1.24 (31.5) 2.50 (63.5)<br />

11 /2-in. NPT 2.36 (59.9) 1.70 (43.2) 1.24 (31.5) 2.50 (63.5)<br />

2-in. NPT 2.74 (69.6) 1.90 (48.3) 1.24 (31.5) 2.50 (63.5)<br />

EN 10226 BSP G1 BSP 2.03 (51.6) 1.09 (27.9) 0.87 (22.0) 2.15 (54.6)<br />

G11 /2 BSP 2.36 (59.9) 1.70 (43.2) 0.98 (24.9) 2.24 (56.9)<br />

G2 BSP 2.74 (69.6) 1.90 (48.3) 1.24 (31.5) 2.50 (63.5)<br />

(1) Dimensions are in inches (millimeters).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 27. SCW Tri-Clamp <strong>Seal</strong><br />

Table 12. SCW Tri-Clamp <strong>Seal</strong> Dimensions (1)<br />

Dimensions are in inches (millimeters)<br />

Pipe Size Outer Diameter “A” O-rIng Groove Diameter “B” Diaphragm Diameter “C”<br />

1 1 /2-in. 2.00 (51) 1.72 (44) 1.21 (31)<br />

2-in. 2.50 (64) 2.22 (56) 1.68 (43)<br />

2 1 /2-in. 3.05 (77) 2.78 (71) 2.07 (53)<br />

3-in. 3.58 (91) 3.28 (83) 2.58 (66)<br />

4-in. 4.68 (119) 4.35 (110) 3.66 (93)<br />

(1) Dimensions are in inches (millimeters).<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

139


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 15. SSW Tank Spud <strong>Seal</strong><br />

Table 71. SSW Tank Spud <strong>Seal</strong> Dimensions (1)<br />

140<br />

Dimensions are in inches (millimeters)<br />

Pipe Size Extension Length “A”<br />

4-in. SCH 5 2-in. Long 2.10 (53)<br />

6-in. Long 6.10 (155)<br />

(1) Dimensions are in inches (millimeters).<br />

Figure 16. STW Hygienic Thin Wall Tank Spud <strong>Seal</strong><br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 17. EES Hygienic Flanged Tank Spud Extended <strong>Seal</strong><br />

Table 72. EES Hygienic Flanged Tank Spud Extended <strong>Seal</strong> Dimensions (1)<br />

Pipe Size Flange<br />

Diameter “A”<br />

Figure 18. VCS Tri-clamp In-Line <strong>Seal</strong><br />

Flange<br />

Thickness “B”<br />

# of Bolts Bolt Circle<br />

Diameter “C”<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

St<strong>and</strong>ard<br />

Diaphragm<br />

Diameter “D”<br />

Extension<br />

Diameter “E”<br />

Bolt Hole<br />

Diameter “F”<br />

DN50 (1) 6.50 (165) 0.79 (20) 4 4.92 (125) 2.99 (76) 3.24 (82) 0.55 (14)<br />

DN80 7.87 (200) 0.94 (24) 8 6.30 (160) 4.04 (102) 4.24 (108) 0.55 (14)<br />

(1) Dimensions are in inches (millimeters).<br />

Table 73. VCS Tri-clamp In-Line <strong>Seal</strong> Dimensions (1)<br />

Pipe Size Inner Diameter “A” Groove Diameter “B” Flange Diameter “C” Outer Diameter “D”<br />

1-in. (1) 0.87 (22) 1.72 (44) 1.99 (51) 2.33 (59)<br />

1½-in. 1.37 (35) 1.72 (44) 1.99 (51) 2.73 (69)<br />

2-in. 1.87 (48) 2.22 (56) 2.52 (64) 3.19 (81)<br />

3-in. 2.87 (73) 3.28 (83) 3.58 (91) 4.14 (105)<br />

4-in. 3.82 (97) 4.35 (110) 4.69 (119) 5.06 (129)<br />

(1) Dimensions are in inches (millimeters).<br />

141


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 19. SVS Varivent Compatible Connection <strong>Seal</strong><br />

Figure 20. SHP Cherry-Burrell “I” Line <strong>Seal</strong><br />

Table 74. SHP Cherry-Burrell “I” Line <strong>Seal</strong> Dimensions (1)<br />

Size Outer Diameter “A” Extension Diameter “B”<br />

2-in. (1) 2.64 (67) 2.24 (57)<br />

3-in. 3.88 (98) 3.31 (84)<br />

Figure 21. SLS Hygienic Dairy Process Connection Female Thread <strong>Seal</strong> per DIN 11851<br />

142<br />

(1) Dimensions are in inches (millimeters).<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Table 75. SLS Hygienic Dairy Process Connection Female Thread <strong>Seal</strong> per DIN 11851 Dimensions<br />

Female Process Size / Hub Diameter “A” “B” Thread Diameter Hub Height “D” “E”<br />

Thread Rating<br />

“C”<br />

DIN 11851 DN 40 PN 40 1.89 (48) (1) 2.20 (56) Rd 65 X 1 /6-in. 1.18 (30) 0.39 (10)<br />

DN 50 PN 25 2.40 (61) 2.70 (69) Rd 78 X 1 /6-in. 1.22 (31) 0.43 (11)<br />

(1) Dimensions are in inches (millimeters).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 22. WSP Saddle <strong>Seal</strong><br />

Table 76. WSP Saddle <strong>Seal</strong> Dimensions (1)<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Size Overall Height “A” Inner Diameter “B” Outer Diameter<br />

Bolt Circle Diameter “D”<br />

“C”<br />

6 Bolts 8 Bolts<br />

2-in. (1)<br />

2.72 (69) 1.50 (38) 2.50 (64) 2.99 (76) 2.91 (74)<br />

3-in. 2.46 (63) 2.01 (51) 3.02 (77) 2.99 (76) 2.91 (74)<br />

4-in. <strong>and</strong> larger 2.60 (66) 2.01 (51) 3.00 (76) 2.99 (76) 2.91 (74)<br />

(1) Dimensions are in inches (millimeters).<br />

143


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 23. UCP <strong>and</strong> PMW Threaded Pipe Mount <strong>Seal</strong>s<br />

Table 77. UCP <strong>and</strong> PMW Threaded Pipe Mount <strong>Seal</strong>s Dimensions (1)<br />

144<br />

UCP<br />

PMW<br />

Dimensions are in inches (millimeters)<br />

Size Overall Diameter “A” Diameter “B” Diaphragm<br />

Diameter “C”<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Sleeve Inner<br />

Diameter “D”<br />

Sleeve 1-in. Pipe 1.50 (38) 1.32 (34) 0.84 (21) 1.04 (26) 1<br />

Threaded M44 X 1.25 2.37 (60) 1.38 (35) 1.32 (32) — —<br />

(1) Dimensions are in inches (millimeters)<br />

1.06<br />

# of Bolts


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Figure 24. CTW Chemical Tee <strong>Seal</strong><br />

Figure 25. TFS Wafer Style In-Line <strong>Seal</strong><br />

Table 78. TFS Wafer Style In-Line <strong>Seal</strong> Dimensions (1)<br />

Dimensions are in inches (millimeters)<br />

Pipe Size Flange Face Diameter “A” Outer Diameter “B” Inner Diameter “C”<br />

1-in. (1)<br />

2.00 (51) 2.64 (67) 1.090 (28)<br />

1 1 /2-in. 2.88 (73) 3.23 (82) 1.61 (41)<br />

2-in. 3.62 (92) 3.74 (95) 2.07 (52)<br />

21 /2-in. 4.12 (105) 4.21 (107) 2.48 (63)<br />

3-in. 5.00 (127) 5.00 (127) 3.07 (78)<br />

4-in. 6.19 (157) 6.19 (157) 4.00 (102)<br />

DN25 2.68 (68) 2.72 (69) 1.09 (28)<br />

DN40 3.46 (88) 3.46 (88) 1.61 (41)<br />

DN50 4.02 (102) 4.09 (104) 1.99 (51)<br />

DN80 5.43 (138) 5.47 (139) 3.24 (82)<br />

DN100 6.38 (162) 6.46 (164) 4.22 (107)<br />

(1) Dimensions are in inches (millimeters).<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

145


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

Figure 26. WFW Flow-Thru Flanged <strong>Seal</strong><br />

Table 79. WFW Flow-Thru Flanged <strong>Seal</strong> Dimensions (1)<br />

Class Nominal<br />

Pipe Size<br />

146<br />

Overall Length<br />

“A”<br />

Dimensions are in inches (millimeters)<br />

Upper to<br />

Centerline Height<br />

“B”<br />

Bolt Circle<br />

Diameter “C”<br />

Outside Diameter<br />

“D”<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Bolt Hole<br />

Diameter “E”<br />

Flange<br />

Thickness “F”<br />

150 lb. 1-in. 7.00 (178) (1)<br />

2.40 (61.0) 3.12 (79) 4.25 (108) 0.62 (16) 0.50 (13)<br />

2-in. 9.00 (229) 3.31 (84) 4.75 (121) 6.00 (152) 0.75 (19) 0.69 (18)<br />

3-in. 11.00 (279) 3.61 (92) 6.00 (152) 7.50 (191) 0.75 (19) 0.88 (22)<br />

(1) Dimensions are in inches (millimeters).


Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

147


<strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong><br />

St<strong>and</strong>ard Terms <strong>and</strong> Conditions of Sale can be found at www.rosemount.com\terms_of_sale<br />

The Emerson logo is a trade mark <strong>and</strong> service mark of Emerson Electric Co.<br />

<strong>Rosemount</strong> , Instrument Toolkit, <strong>and</strong> the <strong>Rosemount</strong> logotype are registerd trademarks of <strong>Rosemount</strong> Inc.<br />

Coplanar <strong>and</strong> Tuned-System Assemblies are trademarks of <strong>Rosemount</strong> Inc.<br />

Instrument Toolkit is a registered trademark of Emerson Process Management.<br />

Varivent is a registered trademark of Tuchenhagen GmbH.<br />

Flourocarbon (FMK) <strong>and</strong> Teflon are registered trademarks of E.I. duPont de Nemours & Co.<br />

Syltherm, <strong>and</strong> D.C. are regiastered trademarks of Dow Corning Corp.<br />

Tri-Clamp is a registered trademark of Tri-Clover, Inc. of the Alfa-Laval Group.<br />

Thermo-Tork is a registered trademark of Armstron World Industries, Inc.<br />

Neobee M-20 is a registered trademark of Stepan Chemical Co.<br />

Windows is a registered trademark of Microsoft Corp.<br />

Cherry-Burrell is a trademark of the United Dominion Industries.<br />

The 3-A symbol is a registered trademark of the 3-A Sanitary St<strong>and</strong>ards Symbol Council.<br />

Many other special order transmitter/seal configurations, materials <strong>and</strong> fill fluids are available that are not covered in this document. Contact<br />

your Emerson Process Management representative or consult factory for additional information.<br />

Emerson Process Management<br />

<strong>Rosemount</strong> Measurement<br />

8200 Market Boulevard<br />

Chanhassen MN 55317 USA<br />

Tel (USA) 1 800 999 9307<br />

Tel (International) +1 952 906 8888<br />

Fax +1 952 906 8889<br />

00813-0100-4016 Rev MB, 9/12<br />

<strong>Rosemount</strong> <strong>Level</strong> Solutions<br />

Emerson provides a complete range of <strong>Rosemount</strong> products for level measurement applications.<br />

Pressure – <strong>Level</strong> or Interface Measurement<br />

Flexible mounting for liquid tank levels, including those with wide<br />

temperature <strong>and</strong> pressure requirements. Can be isolated by<br />

valves. Unaffected by: vapor space changes, surface conditions,<br />

foam, corrosive fluids, internal tank equipment. Optimize<br />

performance with direct mount, Tuned-System Assemblies:<br />

• <strong>Rosemount</strong> <strong>DP</strong> <strong>Level</strong> <strong>Transmitters</strong> <strong>and</strong> Remote <strong>Seal</strong>s<br />

• <strong>Rosemount</strong> 3051SAL, 3051L, <strong>and</strong> 2051L Liquid <strong>Level</strong><br />

<strong>Transmitters</strong><br />

Vibrating Fork Switches – Point <strong>Level</strong> Detection<br />

The <strong>Rosemount</strong> 2100 Series is developed for reliable point level<br />

detection of liquids <strong>and</strong> consists of:<br />

• <strong>Rosemount</strong> 2110 Compact Vibrating Fork Liquid <strong>Level</strong> Switch<br />

• <strong>Rosemount</strong> 2120 Full-featured Vibrating Fork Liquid <strong>Level</strong><br />

Switch<br />

Guided Wave Radar – <strong>Level</strong> <strong>and</strong> Interface Measurement<br />

Multivariable, loop-powered Guided Wave Radar transmitters<br />

with a wide range of probe styles to fit different liquids <strong>and</strong> solids<br />

applications. The product line consists of:<br />

• <strong>Rosemount</strong> 3300 Series – Versatile <strong>and</strong> easy-to-use<br />

transmitter with proven reliability<br />

• <strong>Rosemount</strong> 5300 Series – Accurate, superior performance<br />

transmitter with FOUNDATION fieldbus support<br />

Emerson Process Management<br />

Blegistrasse 23<br />

P.O. Box 1046<br />

CH 6341 Baar<br />

Switzerl<strong>and</strong><br />

Tel +41 (0) 41 768 6111<br />

Fax +41 (0) 41 768 6300<br />

Emerson FZE<br />

P.O. Box 17033<br />

Jebel Ali Free Zone<br />

Dubai UAE<br />

Tel +971 4 811 8100<br />

Fax +971 4 886 5465<br />

Product Data Sheet<br />

00813-0100-4016, Rev MB<br />

September 2012<br />

Non-contacting Radar – <strong>Level</strong> Measurement<br />

The <strong>Rosemount</strong> non-contacting radar family consists of:<br />

• <strong>Rosemount</strong> 5400 Series <strong>Transmitters</strong> – Loop-powered superior<br />

performance transmitter with a wide range of antennas, for<br />

liquid level measurement in most applications <strong>and</strong> process<br />

conditions<br />

• <strong>Rosemount</strong> 5600 Series <strong>Transmitters</strong> – Power of 4-wire give<br />

maximum sensitivity <strong>and</strong> performance for solids, challenging<br />

reactors, rapid level changes <strong>and</strong> excessive process<br />

conditions.<br />

Non-contacting Ultrasonic – <strong>Level</strong> Measurement<br />

The <strong>Rosemount</strong> 3100 Series ultrasonic level transmitters provide<br />

continuous non-contacting level measurement of liquids. The<br />

range consists of:<br />

• <strong>Rosemount</strong> 3101 for simple continuous level measurement<br />

• <strong>Rosemount</strong> 3102 for continuous measurement with two integral<br />

relays for local control functionality<br />

• <strong>Rosemount</strong> 3105 Intrinsically safe certified version for<br />

hazardous areas<br />

Emerson Process Management Asia Pacific<br />

Pte Ltd<br />

1 P<strong>and</strong>an Crescent<br />

Singapore 128461<br />

Tel +65 6777 8211<br />

Fax +65 6777 0947<br />

Service Support Hotline : +65 6770 8711<br />

Email : Enquiries@AP.EmersonProcess.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!