14.07.2013 Views

Water Well Manual (USAID).pdf - The Water, Sanitation and Hygiene

Water Well Manual (USAID).pdf - The Water, Sanitation and Hygiene

Water Well Manual (USAID).pdf - The Water, Sanitation and Hygiene

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A PRAGTICAL GUIDE FOR LOCATI<br />

CONSTRUCTING WELLS FOR INDIVIDUAL<br />

AND SMALL COMMUNITY WATER SUPPLIES


GROUND WATER IS ONE OF MAN’S M’JST IMPORTANT<br />

NATURAL RESOURCES. ITS PROPER UEVELOPMENT<br />

BY MZ:ANS OF WELLS IS A MATTER OF INCREASING<br />

IMPORY’ANCE. THIS BOOK DISCUSSE 5 THE LOCATION,<br />

DESIGN, CONSTRUCTION, OPERATI~JN, AND MAINTE-<br />

NANCE OF SMALL WELLS USED PI:,MARILY FOR<br />

lNDlVlDUAL AND SMALL COMMUl’:ITY WATER<br />

SUPPLIES.<br />

THE AUTvlORS, WRITING IN A Cy,EAR AND EASY-TO-<br />

READ MANNER, PRESENT THE f’:lJNDAMENTALS OF<br />

WATER WELLS SO AS TO BE USEFUL TO INDIVIDUAL<br />

HOME OWNERS, FARMERS, ANI.:) STUDENTS AS WELL<br />

AS TO THOSE PRO’FESSIONALL Y INVOLVED SUCH AS<br />

WELL DRILLING CONTRACTD!ZS, ENGINEERS, AND<br />

GEOLOGISTS.<br />

MODERN TECHNIQUES FOR I.,EVELOPING GROUND<br />

WATER ARE COMPREHENSIVELY DESCRIBED -<br />

WHETHER THE WATER SUPPkIES ARE FOR AGRI-<br />

CULTURAL, INDUSTRIAL, Of,! HUMAN NEEDS. TO<br />

AID UNDERSTANDING THE r”iUTHORS HAVE IN-<br />

CLUDED MORE THAN 100 ILLUSTRATIONS THROUGH-<br />

OUT THE BOQK.<br />

THIS BOOK WAS ORIGINALLY PUBLISHED BY<br />

THE AGENCY FOR INTERNATIONAL DEVELOPMENT<br />

OF THE UNITED STATES GOVERNMENT TO ASSIST<br />

THE PEPPLE LIVING IN THE DEVELOPING COUNTRIES<br />

OF THE WORLD WHO ARE WITHOUT ADEQUATE<br />

SUPPLIES OF GOOD QUALITY WATER. THIS NEW<br />

EeblTlON HAS SEEN PREPARED SO THAT ALL PERSONS<br />

INTERESTED IN WATER RESOURCES MAY BENEFIT<br />

FROM THIS VALWABLE BOOK.


hmier Pwss<br />

Editorial Advisory Boani<br />

for <strong>Water</strong> Resources<br />

Harvey 0. Bat&T<br />

Charles E Meyer<br />

David K. Todd


A PRACTICAL GUlDE FOR LOCATING AND CONSTRUCTING WELLS<br />

FOR lNDh/lDUAL AND SMALL COMMUNITY WATER SUPPLIES<br />

Uhic P. Gibson<br />

Executive Engineer, <strong>Water</strong> Supply, Rural Areas<br />

Ministry of Works & Hydraulics, Guyana<br />

Rexford D. Singer<br />

Associate Professor of Environmental Health<br />

School of Public Health<br />

University of Minnesota<br />

PREMIER PRESS<br />

Berkeley, California


WATER<br />

EL1<br />

MANUAL<br />

Covers Copyright @ by Premier Press 197 !<br />

Published by the<br />

Agency for International<br />

Development of the U.S.<br />

Department of State under<br />

the title Small <strong>Well</strong>s Mamai,<br />

1969.<br />

Text reprinted i971 by<br />

PREMiER PRESS<br />

P. 0. Box 4428<br />

Berkeley, California 94704<br />

Library of Congress<br />

Catalog Card Number: 71-l 53696<br />

Printed in the United States of America<br />

Foul-t11 Printing, May 1977<br />

ii


<strong>The</strong> authors wkh to express their appreciation to the Health Service,<br />

Oftlce of Wt?r on Hunger. United States :lgtfi~q t‘or International Develop-<br />

ment for making the publkation of this manual poss\lble. We art’ particularly<br />

indebted to the UOP-Johnson Division, Universal Oil Products Company, St.<br />

Paul. %Iinnesota for their advice <strong>and</strong> assistance in preparing the tnanuscript<br />

<strong>and</strong> for their contribution of valuable inft)rmstion <strong>and</strong> illustrations <strong>and</strong> to Mr.<br />

Arpad Rumy for the preparation of man i’ of the illustrations. We also wish to<br />

express sincere gratitude to ail pcrs:ns who have offered comments,<br />

suggestions <strong>and</strong> assistance or who have given their time to critically review the<br />

manuscript.<br />

In preparing this manual. an attempt h;ts been made to bring together<br />

information <strong>and</strong> material from a variety of sources. We have endeavored to<br />

give proper credit for the direct use of material from these sources, <strong>and</strong> any<br />

omission of such credit is unintentional.<br />

It has been estimated that nearly two-thirds of the one <strong>and</strong> a half billion<br />

people living in the developing countries are without adequate supplies of<br />

safe water. <strong>The</strong> consequences of this deficiency are innumerable episodes of<br />

the debilitating <strong>and</strong> incapacitating enteric diseases whrch annually affect an<br />

estimated 500 million people <strong>and</strong> result in the deaths of as many as 10<br />

million about half of whom are children.<br />

Although there are many factors limiting the installation of small water<br />

systems, the lack of know!edge in repdd to the availability of ground water<br />

<strong>and</strong> effective means of extracting it fc-11 use by rural communities is a major<br />

element. It is anticipated that this manual will make a major contribution<br />

toward fiiling this need by providing the man in the field, not necessarily an<br />

engineer or hydrologist, with the information needed to locate, construct <strong>and</strong><br />

operate a small well which can provide good quality water in adequate quantities<br />

for small communities.<br />

<strong>The</strong> Agency for International Development takes great pride in cooperating<br />

with the University of Minnesota in making this manual available.<br />

Arthur H. Holloway<br />

Sanitary Engineer,<br />

Health Service, Office of War on Hunger<br />

Agency for International Development<br />

. . .<br />

111


Page<br />

ACKNOWLEDGEMENTS ii<br />

FOREWORD<br />

1. INTRODUCTION 1<br />

PURPOSE 1<br />

SCOPE 1<br />

PUBLIC HEALTH AND RELATED FACTORS 1<br />

Importance of <strong>Water</strong> Supplies. Ground-<strong>Water</strong>’s Impor-<br />

tance. Need for Proper Development <strong>and</strong> Management of<br />

Ground Watt-b Resources.<br />

*L.ORIGiN, OCCllRRENCE AND MOVEMENT OF GROUND<br />

WATER<br />

THE HYDROLOGIC CYCLE 4<br />

SUBSURFACE DISTRIBUTION OF WATER<br />

Zone of Aeration. Zone of Saturation.<br />

GEOLOGIC FORMATIONS AS AQUIFERS<br />

Rock Classification. ‘Role nf Geologic Processes in<br />

Aquifer Formation.<br />

GROUND-WATER FLOW AND ELEMENTARY WELL HY-<br />

DRAULICS 10<br />

Types of Aquifers. A,quifer Functions. Factors Affecting<br />

Permeability. Flow Toward <strong>Well</strong>s.<br />

QUALITY OF GROUND WATER ;72<br />

Physical Quality. Microbiological Quality. Chemical Qual-<br />

ity.<br />

3. GROUND-WATEREXPLORATION<br />

EEOLOGIC DATA<br />

Geologic Maps. Geologic Cross-Sections. Aerial Photo-<br />

graphs.<br />

INYENTORY OF EXISTING WELLS<br />

SURFACE EVIDENCE<br />

iv<br />

. . .<br />

111<br />

4<br />

4<br />

7<br />

28<br />

28<br />

30<br />

31


4. WATER WELL DESIGN<br />

CASED SECTION<br />

BUTARE SECTlON<br />

Type <strong>and</strong> Construction of Screen. Screen Length, Size of<br />

Openings <strong>and</strong> Diameter.<br />

SELECTION OF CASING AND SCREEN MATERIALS<br />

<strong>Water</strong> Quality. Strer&h Requirements. Cost. Miscel-<br />

laneous.<br />

GRAVELPACKING AND FORMATION STABILIZATION<br />

Gravel Packing. Formation Stabilization.<br />

SANITARY PROTECTION<br />

Upper Terminal. Lower Terminal of the Casing. Grouting<br />

<strong>and</strong> Sealing Casing.<br />

5. -#ELL CONSTRUCTION<br />

WELL DRILLING METHODS<br />

Boring. Driving. Jetting. Hydraulic Percussion. Sludger.<br />

Hydraulic Rotary. Cable-Tool Percussion.<br />

INSTALLING WELL CASING<br />

GROUTING AND SEALING CASING<br />

WELL ALIGNMENT<br />

Conditions Affecting <strong>Well</strong> Alignment. Measurement of<br />

<strong>Well</strong> Alignment.<br />

INSTALLATION OF WELL SCXEENS<br />

Pull-back Method. Open Hole Methr?d. Wash-down Meth-<br />

od. <strong>Well</strong> Points. Artificially Gravel-Packed <strong>Well</strong>s. Re-<br />

covering <strong>Well</strong> Screens.<br />

FISHING OPERATIONS<br />

Preventive Measures. Preparations for Fishing. Common<br />

Fishing Jobs <strong>and</strong> Tools.<br />

6. WELL COMPLETION<br />

WELL DEVELOPMENT<br />

Me&an&l Surging. Backwashing. Development of Grav-<br />

el-Packed <strong>Well</strong>s. Dispersing Agents.<br />

WELL DISINFECTION<br />

V<br />

Pi;ge<br />

33<br />

34<br />

34<br />

47<br />

50<br />

52<br />

55<br />

55<br />

69<br />

70<br />

73<br />

75<br />

86<br />

96<br />

96<br />

104


S. PUMPING EQUIPMENT 114<br />

CONSTANT DISPLACE>lE?ZT PLhlPS I17<br />

Reciprocating Piston Pumps. Rotary Pumps. Helical<br />

Rotor Pumps.<br />

VARIABLE DISPl.A(‘EMENl- PUMPS 120<br />

C’en trlfugal Ptuqx. Jet Pumps.<br />

DEEP WELL PUMPS 11-l<br />

Lineshaft Pumps. Subrnersibk P!lrnps.<br />

PRIMING OF PUMPS I 10<br />

PUMP SELECTION 137<br />

SELECTION OF POWER SOLrRCE 11x<br />

Man Power. Wind. Electricity. Internal Combustion<br />

Engine.<br />

4. SANITARY PROTECTION OF GROUND-WATER SUPPLIES 134<br />

POLLUTION TRAVEL IN SOILS<br />

WELL LOCATiON<br />

SEALING ABANDONED WELLS<br />

REFERENCES<br />

CWEDI’i FOR ILLUSTRATIONS<br />

APPENDICES<br />

APPENDIX A. MEASUREMENT OF PERMEABILITY<br />

138<br />

139<br />

14(!<br />

APPENDIX B. USEFUL TABLES AND FORMULAS 111<br />

INDEX 151<br />

vi


C PTER ‘I<br />

I CTI<br />

PURPOSE<br />

This manual is intended to serve as a basic introductory text book <strong>and</strong> to<br />

provide instruction <strong>and</strong> guidance to field personnel engaged in the construc-<br />

tion, operation <strong>and</strong> maintenance of small diameter, relatively shallow wells<br />

used primarily for individual <strong>and</strong> small community water supplies.<br />

it is aimed particularly at those persons who have had little or no<br />

experience in the subject. An attempt has been made to treat the subject<br />

matter as simply as possible in order that this manual may bF: of benefit not<br />

only to the engineer or other technically trained individual (inexperienced in<br />

this field) but also the individual home owner, farmer or non-technically<br />

trained community development officer. This manual should also prove<br />

useful in the training of water well drillers, providing the complementary<br />

background material for their field experience. <strong>The</strong> reader who is interested<br />

in pursuing the subject further, <strong>and</strong> with reference to larger <strong>and</strong> deeper wells,<br />

is referred to the list of references to be found at the end of this manual.<br />

SCOPE<br />

This. manual covers the exploration <strong>and</strong> development of ground-water<br />

sources in unconsolidated formations, primarily for the provision of small<br />

potabie water supplies. Its scope has been limited to the consideration of<br />

small tube wells up to 4 inches in diameter, a maximum of approximately<br />

100 feet in depth <strong>and</strong> with yields of up to about 50 U.S. gallons per minute<br />

(All references are to U.S. units. Conversion tables are to be found in<br />

Appendix B). <strong>The</strong> location, design, construction, maintenance <strong>and</strong> rehabilita-<br />

tion of such wells are among the various aspects discussed. <strong>The</strong> above<br />

limitation on well size (diameter) rules out the zonslderation of dug we!ls in<br />

favor of the much more efficient <strong>and</strong> easier to protect bored, driven, jetted or<br />

drilled tube wells. However, a method of converting existing dug wells to tube<br />

wells is discussed.<br />

PUBLIC HEALTH AND RELATED FACTORS<br />

hportance of <strong>Water</strong> Supplies<br />

<strong>Water</strong> is, with the exception of ai?, the most important single substance to<br />

man’s survival. Man, like all other forms of biological life, is extremely<br />

dependent upon water <strong>and</strong> can survive much longer without food than he can<br />

without water. <strong>The</strong> quantities of water directly required for the proper<br />

functioning of the body processes are relatively small but essential.<br />

1


While man has always recognized ihe importance of water for his internal<br />

bodily needs. his recognition of its importance to health is a more recent<br />

development. dating back oniy a century or so. Since that time, much has<br />

been learned about the role of inadequate <strong>and</strong> contaminated water supplies in<br />

the spread of water-borne diseases. Among the first diseases recognized to be<br />

water borne were cholera <strong>and</strong> typhoid fever. Later, dysentery, gastroenteritis<br />

<strong>and</strong> other diarrhea1 diseases were added to the list. More recently, water has<br />

also been shown to play an important role in the spread of certain viral<br />

diseases such as infectious hepatitis.<br />

<strong>Water</strong> is involved in the spread of conznunicable diseases in essentially two<br />

ways. <strong>The</strong> first is the well known direct ingestion of the infectious agent<br />

when drinking contaminated water (e.g. dysentery, typhoid <strong>and</strong> other<br />

gastrointestinal diseases). <strong>The</strong> second is due to a lack of sufficient water for<br />

personal hygiene purposes. Inadequate quantities of water for the maintenance<br />

of personal hygiene <strong>and</strong> environmental sanitation have been shown to<br />

be major contributing factors in the spread of such diseases as yaws <strong>and</strong><br />

typhus. Adequate supplies of water for personal hygiene also diminish the<br />

probability of transmitting some of the gastrointestinal diseases mentioned<br />

above. <strong>The</strong> latter type of interaction between water <strong>and</strong> the spread of disease<br />

has been recognized by various public health organizations in developing<br />

countries which have been trying to provide adequate quantities of water of<br />

reasonable, though not entirely satisfactory, quality.<br />

Health problems related to the inadequacy of water supplies are universal<br />

but, generally, of greater magnitude <strong>and</strong> significance in the underdeveloped<br />

<strong>and</strong> developing nations. It has been estimated that about two-thirds of the<br />

population of the developing countries obtain their water from contaminated<br />

?111!3rees. <strong>The</strong> World Health Organization estimates that each year 500 million<br />

people suffer from diseases associated with unsafe water supplies. Due largely<br />

to poor water supplies, an estimated S,OOO,OOO infants die each year from<br />

diarrheal diseases.<br />

In addition to the human consumption <strong>and</strong> health requirements, water is<br />

a!so needed for agricultural, industrial <strong>and</strong> other purposes. Though all of<br />

these needs are important, water for human consumption <strong>and</strong> sanitation is<br />

considered to be of greater social <strong>and</strong> economic importance since the health<br />

of the population influences all other activities.<br />

Ground-<strong>Water</strong>’s Importance<br />

It can generally be said that ground water has played a much less<br />

imporatnt role in the solution of the world’s water supply problems than its<br />

relative availability would indicate. Its outaf-sight location <strong>and</strong> the associated<br />

lack of knowledge with respect to its occurrence, movement <strong>and</strong> development<br />

have no doubt contributed greatly to this situation. <strong>The</strong> increasing acquisition<br />

<strong>and</strong> dissemination of knowledge pertaining to ground-water development will<br />

gradually allow the use of this source of water to approach its rightful’degree<br />

of importance <strong>and</strong> usefulness.<br />

More than 97 percent of the fresh wn:lter on our planet (excluding that in<br />

the polar ice-caps <strong>and</strong> glaciers) is to be found underground. While it is not<br />

2


practicable to extract all of this water because of economic tend other re;lsons.<br />

the recoverable quantities would. no doubt, esceed the available supplies of<br />

fresh surface water found in rivers <strong>and</strong> lakes.<br />

Ground-water sources also represent water that is essentially irl ;iorage<br />

while the water in rivers <strong>and</strong> lakes is generally i.n transit, being replaced<br />

several times a year. <strong>The</strong> available quantity of surface water at any given<br />

location is also more subject to seasonal fluctuations than is ground water. In<br />

many areas, the extraction of ground water can be continued long after<br />

droughts have completely depleteil rivers. Ground-water sources are, therefore,<br />

more rehable sources of water in many instances.<br />

As will be seen in Chapter 2. ground waters are usually of much better<br />

quality than surface waters. due to the benefits of percolation through the<br />

ground. Oftener than not, ground water is also mctre readily available where<br />

needed, requiring less transportation <strong>and</strong>, generally, costir?.g less to develop.<br />

Greater emphasis should, therefore, be placed on the development <strong>and</strong> use of<br />

the very extensive ground-water sources to be found throughout the world.<br />

Need for Proper Development <strong>and</strong> Management of Ground-<strong>Water</strong> Resources<br />

While some ground-water reservoirs are being repienished year after year<br />

by infiltration from precipitation, rivers, canals <strong>and</strong> so on, others are being<br />

replenished to much lesser degrees or not at all. Extraction of water from<br />

these latter reservoirs results in the continued depletion or mining of the<br />

water.<br />

Ground water aiso often seeps into streams, thus providing the low flow<br />

(base flow) that is sustained through the driest period of the year. Conversely,<br />

if the surface water levels in streams are higher than those in ground-water<br />

reservoirs, then seepage takes place in the opposite direction, from the<br />

streams into the ground-water reservoirs. Uncontrolled use of ground water<br />

can, therefore, affect the levels of streams <strong>and</strong> Iakes <strong>and</strong> consequen.tly the<br />

uses to which they are normally put.<br />

Ground-water development presents special problems. <strong>The</strong> lack of solu-<br />

tions to these problems have, in the past, contributed to the mystery that<br />

surrounded ground-water development <strong>and</strong> the limited use to which ground<br />

water has been put. <strong>The</strong> proper development <strong>and</strong> management of ground-<br />

water resources requires a knowiedge of the extent of storage, the rates of<br />

discharge from <strong>and</strong> recharge to underground reservoirs, <strong>and</strong> the use of<br />

economical means of extraction. It may be necessary to devise artificial<br />

means of recharging these reservoirs where no natural sources exist or to<br />

supplement the natural recharge. Research has, in recent years, considerably<br />

increased our knowledge of the processes involved in the origin <strong>and</strong><br />

movement of ground water <strong>and</strong> has provided us with better methods of<br />

development <strong>and</strong> conservation of ground-water supplies. Evidence of this<br />

increased knowledge is to be found in the greater emphasis being placed on<br />

ground-water development.


An underst<strong>and</strong>ing of the processes <strong>and</strong> fxtors affecting the origin,<br />

occurrence, <strong>and</strong> movement of ground water is essential to the proper<br />

development <strong>and</strong> use of ground-water resources. Of importance in determin-<br />

ing 2 satisfactory rate of extraction <strong>and</strong> suitable uses of the water are a<br />

knowledge of the quantity of water present, its origin. the direction <strong>and</strong> rate<br />

of movement to its poi:rt of discharge, the discharge rate <strong>and</strong> the rate at<br />

which it is being replenished, <strong>and</strong> the quality of the water. <strong>The</strong>se points are<br />

considered in this chapter in as simplified <strong>and</strong> limited a form as the aims <strong>and</strong><br />

scope of this manual permit.<br />

THE HYDROLQGIC CYCLE<br />

<strong>The</strong> hydrologic cycle is the name given to the circulation of water in its<br />

liquid, vapor, or solid state from the oceans to the air, air to l<strong>and</strong>, over the<br />

l<strong>and</strong> surface or undergrountl, <strong>and</strong> back to the oceans (Fig. 2.1).<br />

Evaporation, taking place at the water stirface of oceans <strong>and</strong> other open<br />

bodies of water, results in the transfer of water vapor to the atmosphere.<br />

Under certain conditions, this water vapor condenses to form clouds which<br />

subsequently release their moisture as precipitation in the form of rain, hail.<br />

sleet, or snow. Precipitation may xcur over the oceans retuning some of the<br />

water directly to them or over l<strong>and</strong> to which winds have previously<br />

transported the moisture-laden air <strong>and</strong> clouds. Part of the rain falling to the<br />

earth evaporates with immediate return of moisture to the atmosphere. Of<br />

the remainder, some, upon reaching the ground surface, wets it <strong>and</strong> runs off<br />

into surface streams finally discharging in the ocean while another part<br />

infiltrates into the ground <strong>and</strong> then percolates to the ground-water flow<br />

through which it later reaches the ocean. Evaporation returns some of the<br />

water from the wet l<strong>and</strong> surface to the atmosphere while plants extract some<br />

of that portion in the soil through their roots <strong>and</strong>, by a process known as<br />

transpiration, return it through their leaves to the atmosphere.<br />

SUBSURFACE DISTRIBUTION OF WATER<br />

Subsurface water found in the interstices or pores of rocks may be divided<br />

into two main zones (Fig . 2.2). <strong>The</strong>se are the zvtle of aeration <strong>and</strong> the .zo/re<br />

of saturation.<br />

Zone of Aeration<br />

<strong>The</strong> zone of aeration extends from the l<strong>and</strong> surface to the level at which<br />

all of the pores or open spaces in the earth’s materials are completely fiiled or<br />

4


I<br />

--<br />

---_-<br />

_<br />

_ - -; _ - .--<br />

. .<br />

t-%rcolarlon<br />

- -<br />

V Fresh ground water ~-1.w<br />

-- -.<br />

\ \I / /<br />

n<br />

- Sun -<br />

--- -.- -<br />

formotionr<br />

TJ .--<br />

7 --- ..-_ IF --‘-- -- - -c-- - -<br />

__ __ - -: tmpermeable<br />

- -_._- z --<br />

--- ___ - -z -..<br />

- --<br />

--<br />

.- - - -.<br />

---_ --___ -a. - -~ - - ----<br />

-- --- -~<br />

Fig. 2.1 THE HYDROLOGIC CYCLE.<br />

--<br />

1,.-1 nrnnn


Bsit of Soil <strong>Water</strong><br />

tntermediate Belt<br />

Capillary Fringe<br />

<strong>Water</strong>. Table t<br />

-- -<br />

Ground <strong>Water</strong><br />

Fig. 2.2 DIVISIONS OF SUBSUR-<br />

FACE WATER.<br />

.<br />

saturated with water. A mixture of<br />

air <strong>and</strong> water is to be found in the<br />

pores in this zone <strong>and</strong> hence its<br />

name. It may be subdivided into<br />

three belts. <strong>The</strong>se are (1) the belt of<br />

soil water, (3) the intermediate belt<br />

<strong>and</strong> (3) the capillary fringe.<br />

<strong>The</strong> be/r of soil wafer lizs im-<br />

mediately below the surface <strong>and</strong> is<br />

that region from which plants ex-<br />

tract, by their roots, the moisture<br />

necessary for growth. <strong>The</strong> thickness<br />

of the belt differs greatly with the<br />

type of soil <strong>and</strong> vegetation, ranging<br />

from a few feet in grass-l<strong>and</strong>s <strong>and</strong><br />

field crop areas to several feet in<br />

forests <strong>and</strong> l<strong>and</strong>s supporting deep-<br />

rooted plants.<br />

<strong>The</strong> qdlary ftitlge occupies the<br />

bottom portion of the zone of<br />

aerh:ion <strong>and</strong> lies immediately above<br />

the zone of saturation. Its name<br />

comes from the fact that the water<br />

in this belt is suspended by capil-<br />

iary forces similar to those which<br />

cause water to rise in a narrow or<br />

capillary tube above the level of the<br />

water in a larger vessel into which the tube has been placed upright. <strong>The</strong><br />

narrower the tube or the pores, the higher the water rises. Hence, the<br />

thickness of the belt depends upon the texture of the rock or soil <strong>and</strong> may be<br />

practically zero where the pores are large.<br />

<strong>The</strong> intemrediute belt lies between the belt of soil water <strong>and</strong> the capillary<br />

fringe. Most of its water reaches it by gravity drainage downward through the<br />

belt of soil water. <strong>The</strong> wster in this belt is called intermediate (vadose) water.<br />

Zone of Saturation<br />

Immediately below the zone of aeration lies the zone of saturation in<br />

which the pores are completely fdled or saturated with water. <strong>The</strong> water in<br />

the zone of saturation is known as ground water <strong>and</strong> is the only form of<br />

subsurface water that will flow readiiy into 3 well. <strong>The</strong> object of well<br />

construction is to penetrate the earth into this zone with a tube, the bottorn<br />

section of which has openings which are sized such as to permit the inflow of<br />

water from the zone of saturation but to exclude its rock particles.<br />

Formations which contain ground water <strong>and</strong> will readily yield it to wells are<br />

called aquifers.<br />

5<br />

6


IC FQRXA~NMIIS AS AQUIFERS<br />

For convenience, . :)iogists describe all earth materials as roclis. Rocks<br />

may be of the ~~onti.J ‘,-refl type (held firntiy together by compaction,<br />

cementation <strong>and</strong> otLe:, K A~.,P sut!~ :ts granite. s<strong>and</strong>r’,>r-* e;\d limestone or<br />

rtrncomoiidated type (IL, .-:aterials) such as clay, s<strong>and</strong> Jnd gravel. <strong>The</strong> terms<br />

hml <strong>and</strong> soft are also usr,~: r.o describe consolidated <strong>and</strong> unconsolidated rocky<br />

respectively.<br />

Aquifers may be composed of consolidated or unconsolidated rocks. <strong>The</strong><br />

rock materiais must be sufficiently porous (contain a reasonably high<br />

proportion of pores or other openings to solid material) <strong>and</strong> be sufficiently<br />

permeable (the openings must be interconnected to permit the travei of water<br />

through them).<br />

Rock Classification<br />

Rocks may be classified with respect to their or+;? into the three main<br />

categories cf sedimentary rocks, igneous rocks, <strong>and</strong> lxidmorphic rocks.<br />

Sedimentary rocks are the deposits of material derived from the<br />

weathering <strong>and</strong> erosion of other rocks. Though constituti;.; only about 5<br />

percent of the earth’s crust they contain an estimated 95 percent of the<br />

available ground water.<br />

Sedimentary rocks may be consolidated or unconsolidated depending<br />

upon a number of ?‘zctors such as the type of parent rock, mode of<br />

weathering, means of transport, mode of deposition, <strong>and</strong> the extent to which<br />

packing, compactiorl, <strong>and</strong> cementation have taken place. Harder rocks<br />

generally produce sediments of coarser texture than softer ones. Web;>erin;<br />

by mechanical disintegration (e.g. rock fracture due to temperature varlu<br />

tions) produces coarser sediments than those produced by chemical decom-<br />

position. Deposition in water provides more sorting <strong>and</strong> better packing of<br />

materials than does deposition directly onto l<strong>and</strong>. Chemical constituents in<br />

the parent rocks <strong>and</strong> the environment are responsible for the cemerltatioll of<br />

unconsolidated rocks into hard, consolidated ones. <strong>The</strong>se factors aiso<br />

influence the water-bearing capacity of sedimentary rocks. Disintegrated shale<br />

sediments are usually fine-grained <strong>and</strong> make poor aquifers while sediments<br />

derived from granite or other crystalline rocks usually form good s<strong>and</strong> <strong>and</strong><br />

gravel aquifers, particularly when considerable water transportation has<br />

resulted in well-rounded <strong>and</strong> sorted particles.<br />

S<strong>and</strong>, gravel, <strong>and</strong> mixtures of s<strong>and</strong> <strong>and</strong> gravel are among the unconsoli-<br />

dated sedimentary rocks that form aquifers. Granular <strong>and</strong> unconsolidated,<br />

they va.ry in particle size <strong>and</strong> in the degree of sorting <strong>and</strong> rounding of the<br />

particies. Consequently, their water-yielding capabilities vary considerably.<br />

However, they consitute the best water-bearing formations. <strong>The</strong>y are widely<br />

distributed throughout the world <strong>and</strong> produce very significant proportions of<br />

the water used in many countries.<br />

Other unconsolidated sedimentary aquifers include marine deposits,<br />

alluvial or stream deposits (including deltaic deposits <strong>and</strong> alluviai fans), glacial<br />

drifts <strong>and</strong> wind-blown deposits such as dune s<strong>and</strong> <strong>and</strong> loess [very fine silty<br />

deposits). Great variations in the water-yielding capabilities of these forma-<br />

tions can also be expected. For example, the yield from wells in s<strong>and</strong> dunes<br />

7


<strong>and</strong> loess may be limited by both the fineness of the material <strong>and</strong> the limited<br />

areal extent <strong>and</strong> thickness of the deposits.<br />

Limestone, essentially calcium carbonate. <strong>and</strong> dolomite or calcium-<br />

magnesium carbonate are examples of consolidated sedimentary rocks known<br />

to function as aquifers. Fractures <strong>and</strong> crevices caused by earth movement,<br />

<strong>and</strong> later enlarged into solution channels by ground-water flow through them,<br />

form the connected o:,enings through which flow takes place (Fig. 2.3).<br />

Flows may be considerable where solution channels have developed.<br />

A<br />

Fig.2.3 A.FRACXJRESlNDENSELIMESTONETHROUGHWHICHFLOWMAY<br />

OCCUR.<br />

B. SOLUTION CHANNELS IN LIMESTONE CAUSED BY GROUND-<br />

WATERFLOWTHROUGHFRACTURES.<br />

S<strong>and</strong>stone, usually formed by compactron of s<strong>and</strong> deposited by rivers near<br />

existing sea shores, is another form of consolidated sedimentary rock that<br />

performs as an aquifer. <strong>The</strong> cementing agents are responsible for the wide<br />

range of colors seen in s<strong>and</strong>stones. <strong>The</strong> water-yielding capabilities of<br />

s<strong>and</strong>stones vary with the degree of cementation <strong>and</strong> fracturing.<br />

Shales <strong>and</strong> other similar compacted <strong>and</strong> cemented clays, such as mudstone<br />

or siltstone, are usually not considered to be aquifers but have been known to<br />

yield small quantities of water to wells in localized areas where earth<br />

movements have substantially fractured such formations.<br />

Igneous rocks are those resulting from the cooling <strong>and</strong> solidification of<br />

hot, molten materials called magma which originate at great depths within the<br />

earth. When solidification takes place at considerable depth, the rocks are<br />

referred to as intrusive or plutonic while those solidifying at or near the<br />

ground surface are called extrusive or volcanic.<br />

Plutonic rocks such as granite are usually coarse-textured <strong>and</strong> non-porous<br />

<strong>and</strong> are not considered to be aquifer;. However, water has occasionally been<br />

found in crevices <strong>and</strong> fractures ol the upper, weathered portions of such<br />

rocks.<br />

Volcanic rocks, because of the relatively rapid cooling taking place at the<br />

surface, are usually fine-textured <strong>and</strong> glassy in appearance. Basalt or trap<br />

rock, one of tlze chief rocks of this type, can be highly porous <strong>and</strong><br />

permeable as a result of interconnected openings called vesicles formed by the<br />

development of gas bubbles as the lava (magma flowing at or near the surface)<br />

cools. Basaltic aquifers may also contain water in crevices <strong>and</strong> broken up or<br />

brecciated tops <strong>and</strong> bottoms of successive layers.<br />

8<br />

B


Fragmental materials discharged by volcanos. such as ash <strong>and</strong> cinders, have<br />

been known to form excellent aquifers where particle sizes are sufficiently<br />

large. <strong>The</strong>ir water-yielding capabilities vary considerably, depending on the<br />

complexity of stratification, the range of particle sizes, <strong>and</strong> shape of the<br />

particles. Examples of excellent aquifers of this type are to be found in<br />

Central America.<br />

Metanwrphic rock is the name given to rocks of all types, igneous or<br />

sedimentary, which have been altered by beat <strong>and</strong> pressure. Examples of<br />

these are quart&e or metamorphosed s<strong>and</strong>stone, slate <strong>and</strong> mica schist from<br />

shale, <strong>and</strong> gneiss from granite. Generally, these form poor aquifers with water<br />

obtained only from cracks <strong>and</strong> fractures. Marble, a metamorphosed lime-<br />

stone, can be a good aquifer when fractured <strong>and</strong> containing solution channels.<br />

With the above description of the three main rock types, it should now be<br />

easier to underst<strong>and</strong> why an estimated 95 percent of the available ground<br />

water is to be found in sedimentary rocks which constitute only about 5<br />

percent of the earth’s crust. <strong>The</strong> wells described in this manual will be those<br />

constructed in unconsolidated sedimentary rocks which are undoubtedly the<br />

most important sources of water for small community water supply systems.<br />

Role of Geologic Processes in Aquifer Formation<br />

Geologic processes are continually, though slowly, altering rocks <strong>and</strong> rock<br />

formations. So slowly are these changes taking place that they are hardly<br />

perceptible to the human eye <strong>and</strong> only barely measurable by the most<br />

sensitive instruments now available. Undoubtedly, however, mountains are<br />

being up-lifted <strong>and</strong> lowered, valleys filled or deepened <strong>and</strong> new ones created,<br />

sea shores advancing <strong>and</strong> retreating, <strong>and</strong> aquifers created <strong>and</strong> destroyed.<br />

<strong>The</strong>se changes are more obvious when referred to a geologic timetable with<br />

units measured in thous<strong>and</strong>s <strong>and</strong> ,millions of years <strong>and</strong> to which reference can<br />

be made .in almost any book on geology.<br />

Geologically old as well as young rocks may form aquifers but generally<br />

the younger ones which have been subjected to less compression <strong>and</strong><br />

cementation are the better producers. Geologic processes determine the<br />

shape, extent, <strong>and</strong> hydraulic or flow characteristics of aquifers. Aquifers in<br />

sedimentary rock formations for example vary considerably depending upon<br />

whether the sediments are terrestrial or marine in nature.<br />

Terrestrial sediments, or materials deposited on l<strong>and</strong>, include stream, lake,<br />

glacial, <strong>and</strong> wind-blown deposits. With but few exceptions they are usually of<br />

limited extent <strong>and</strong> discontinuous, much more so than are marine deposits.<br />

Texture variations both laterally <strong>and</strong> vertically are characteristic of these<br />

formations.<br />

AZZMaI or stream deposits are generally long <strong>and</strong> narrow. Usually<br />

SUbSUrface, or below the valley floor, they may also be in the form of terraces<br />

indicating the existence of higher stream beds in the geologic past. <strong>The</strong><br />

material in such aquifers may range in size from fine s<strong>and</strong> to gravel <strong>and</strong><br />

boulders. Ab<strong>and</strong>oned stream courses <strong>and</strong> their deposits are sometimes buried<br />

under wind-home or glacial depos,ts with no visible evidence of their<br />

existence. Where a rapidly flowing stream such as a mountain stream<br />

encounters a rapid reduction of slope, the decrease in velocity causes a<br />

9


deposition of large aprons of material known as alluvial fans. <strong>The</strong>se sediments<br />

range from coarser to finer material as one proceeds away from the<br />

mountains.<br />

Glacial deposits found in North Central U.S.A., Southern Canada, <strong>and</strong><br />

Northern Europe <strong>and</strong> Asia may bc extensive where they result from<br />

continental glaciers as compared to the more localized deposits of mountain<br />

glaciers. <strong>The</strong>se deposits vary in shape <strong>and</strong> thickness <strong>and</strong> exhibit a lack of<br />

interconnection because of the clay <strong>and</strong> silt accumulations within the s<strong>and</strong>,<br />

gravel <strong>and</strong> boulders. Outwash deposits swept out of the melting glacier by<br />

melt-water streams are granular in nature <strong>and</strong> similar to alluvial s<strong>and</strong>s. <strong>The</strong><br />

swifter melt-water streams produce the best glacial drift aquifers.<br />

Lake deposits are generally fine-textured, granular material deposited in<br />

quiet water. <strong>The</strong>y vary considerably in thickness, extent, <strong>and</strong> shape <strong>and</strong> make<br />

good aquifers only when they are of substantial thickness.<br />

GROUND-WATER FLOW AND ELEMENTARY WELL HYDRAULICS<br />

Types of Aquifers<br />

Ground-water aquifers may be classified as either water-table or artesian<br />

aquifers.<br />

A water-table aquifer is one which is not confined by an upper<br />

impermeable layer. Hence, it is also called an unconfined aquifer. <strong>Water</strong> in<br />

these aquifers is virtually at atmospheric pressure <strong>and</strong> the upper surface of the<br />

zone of saturation is called the water table (Fig. 2.2). <strong>The</strong> water table marks<br />

the highest level to which water will rise in a well constructed in a water-table<br />

aquifer. <strong>The</strong> upper aquifer in Fig. 2.4 is an example of a water-table aquifer.<br />

An artesian aquifer is one in which the water is confined under a pressure<br />

greater than atmospheric by an overlying, relatively impermeable layer.<br />

Hence, such aquifers are also called confined or pressure aquifers. <strong>The</strong> name<br />

artesian owes its origin to Artois, the northernmost province of France, where<br />

the first deep wells to tap confined aquifers were known to have been drilled.<br />

Unlike water-table aquifers, water in artesian aquifers will rise in wells to<br />

levels above the bottom of the upper confining layer. This is because of the<br />

pressure created by that confining layer <strong>and</strong> is the distinguishing feature<br />

between the two types of aquifers.<br />

<strong>The</strong> imaginary surface to which water will rise in wells located throughout<br />

an artesian aquifer is called the piezomettic surface. This surface may be<br />

either above or below the ground surface at different parts of the same<br />

aquifer as is shown in Fig. 2.4. Where the piezometric surface lies above the<br />

ground surface, a well tapping the aquifer will flow at ground level <strong>and</strong> is<br />

referred to as a flowing artesian well. Where the piezometric surface lies<br />

below the ground surface, a non$owing artesiarl well results <strong>and</strong> some means<br />

of lifting water, such as a pump, must be provided to obtain water from the<br />

well. It is worthy of note here that the earlier usage of the term artesian well<br />

referred only to the flowing type while current usage includes both flowing<br />

<strong>and</strong> non-flowing wells, provided the water level in the well rises above the<br />

bottom of the confming layer or the top of the aquifer.<br />

10


Ground<br />

surfuce7<br />

Nonflowing<br />

artesian<br />

Woter-<br />

Fig. 2.4 TYPES OF AQUIFERS.<br />

Flowing<br />

. .<br />

artesian<br />

Recharge area<br />

at autc?opping<br />

of formation<br />

<strong>Water</strong> usually enters an artesian aquifer in an area where it rises to the<br />

ground surface <strong>and</strong> is exposed (Fig. 2.4). Such an exposed area is called a<br />

rechmge area <strong>and</strong> the aquifer in that area, being unconfined, would be of the<br />

water-table type. Artesian aquifers may also receive water underground from<br />

leakage through the confining layers <strong>and</strong> at intersections with other aquifers,<br />

the recharge areas of which are at ground level.<br />

Aquifer Functions<br />

<strong>The</strong> openings <strong>and</strong> pores in a water-bearing formation may be considered as<br />

a network of interconnected pipes through which water flows at very slow<br />

rates, seldom more than a few feet per day, from areas of recharge to areas of<br />

discharge. This network of pipes, therefore, serves to provide both storage<br />

<strong>and</strong> flow or conduit functions in an aquifer.<br />

Stooge fin&on: Related to the storage function of an aquifer are two<br />

important properties known as porosity <strong>and</strong> specific yieZd.<br />

<strong>The</strong> porosiZy of a water-bearing formation is that percentage of the total<br />

volume of the formation which consists of openings or pores. For example,<br />

the porosity of one cubic foot of s<strong>and</strong> which contains 0.25 cubic foot of<br />

open spaces is 25 percent. It is therefore evident that porosity is an index of<br />

the amount of ground water that can be stored in a saturated formation.<br />

<strong>The</strong> amount of water yielded by, or that may be taken from, a saturated<br />

formation is less than that which it holds <strong>and</strong> is, therefore, not represented by<br />

11


the pc>:ti,sity. This quautity is related tu the property known 9s t+e ::pec*ijk<br />

yield <strong>and</strong> defined as the volume of water released front ;I unit volu:;~e of the<br />

aquifer material when allowed to drain freely by gravity (Fig. 7.5). TIK<br />

Static woter<br />

tese, - j’<br />

<strong>Water</strong> drotned by<br />

growtty from 1.0<br />

cu ft of s<strong>and</strong><br />

,f<br />

,,A!+--<br />

. ’ ft<br />

,“ ., .~::.~~:.~~~:~:<br />

.‘.‘. _._.(. 1:<br />

‘C ..,.,., ::>:.:.<br />

Fig. 2.5 VISUAL REPRESENTATION<br />

OF SPECIFIC YIELD. ITS<br />

VALUE HERE IS 0.10 CU<br />

L’IXXCAFT OF AQUIFER<br />

.<br />

rennaining vulunte uf water not re-<br />

moved by gravity drainage is held by<br />

cupiktry forces sucl~ as found in<br />

the capillary fringe <strong>and</strong> by other<br />

forces of attraction. It is called<br />

the specific’reterttiott <strong>and</strong>. like<br />

the specific yield. may be ex-<br />

pressed as a decimal fraction or<br />

percentage. As defined, porosity is<br />

therefore equal to the sum of the<br />

specific yield <strong>and</strong> the specific reten-<br />

tion. An aquifer with a porosity of<br />

0.25 or 25 percent <strong>and</strong> a specific<br />

yield of 0.10 or 10 percent would,<br />

therefore, have a specific retcnt ion<br />

of 0.1 S or IS percent. One million<br />

cubic feet of such an aquifel would<br />

contain 250,000 cubic feet ofwate~<br />

of which 100,000 cubic feet would<br />

be yielded by gravity drainage.<br />

Conduit jim.ticm: <strong>The</strong> property<br />

of an aquifer related to its conduit<br />

function is known as the perttw-<br />

ubility.<br />

PL-meability is a measure of the<br />

capacity of an aquifer to transmit<br />

water. It is related to the pressure<br />

difference <strong>and</strong> velocity of flow be-<br />

tween two points under laminar or<br />

non-turbulent c<strong>and</strong>itions by the following equation known as Darcy’s Law<br />

(after iierrry Darcy, the French engineer who developed it).<br />

where V<br />

h,<br />

hz<br />

P<br />

P<br />

is the velocity of flow in feet per day,<br />

(2. I)<br />

is the pressure at the point of entrance to the section of<br />

conduit unlder consideration in feet of water,<br />

is the pressure at the point of exit of the same section in feet<br />

of water,<br />

is the length of the section of conduit in feet, <strong>and</strong><br />

is a constant known as the coefficient of permeability but<br />

often referred to simply as the permeability.


Equation (2.1) may be modified to read<br />

h1 - hz<br />

. where I = -, P<br />

c<br />

Slope equals hydmulic<br />

. .<br />

. .<br />

gradient<br />

.---.<br />

-7,<br />

‘.<br />

Direction of flow<br />

from I to 2<br />

v = PI<br />

<strong>and</strong> is called the hydraulic gradient.<br />

-<br />

‘.. ,, ,:.<br />

,, _, . . ,. ..,‘, ‘.<br />

::<br />

.<br />

;. . ...,.,. “.<br />

,...;..~ :.-. . _ ‘.‘..‘...‘. ,: ‘:. . ) .;. ., :::<br />

Fig 2.6 SECTiON THROUGH<br />

WATER-BEARING SAND<br />

SHOWING THE PRESSURE<br />

DIFFERENCE thl- hd<br />

CAUSING FLOW BETWEEN<br />

POINTS 1 AND 2. THE HY-<br />

DRAULIC GRADIEhTIS<br />

EQUAL TO TME PRESSURE<br />

DIFFERENCE DIVIDED BY<br />

THE DISTANCE, i!, BE-<br />

TWEEN THE POINTS.<br />

(2.2)<br />

<strong>The</strong> quantity of flow per unit of<br />

time through a given cross-sectional<br />

area may be obtained from equation<br />

(2.2) by multiplying the velocity of<br />

flow by that area. Thus,<br />

Q=AV=PIA (2.3)<br />

where Q is the quanity of flow<br />

per unit of time<br />

<strong>and</strong> A is the cross-sectional<br />

area.<br />

Based on equation (2.3) the co-<br />

efficient of perrneubility may,<br />

therefore, be defined as the quan-<br />

tity of hater that will flow through<br />

a unit cross-sectional area of porous<br />

material in unit time under a hy-<br />

draulic gradient of unity (or I = 1 .O)<br />

at a specified temperature, usually<br />

taken as 60°F. In ground-water<br />

problems, Q is usually expressed in<br />

gallons per day (gpd), A in square<br />

feet (sq ft) <strong>and</strong> P, therefore, in<br />

gallons per day per square foot<br />

(gpd/sq ft). <strong>The</strong> coefficient of per-<br />

meability can also be expressed in<br />

the metric system using units of liters per day per square meter under a<br />

hydraulic gradient of unity <strong>and</strong> at a temperature of 15S”C.<br />

It is important to note that Darcy’s Law in the form shown in equation<br />

(2.3) states that the quantity of water flowing under iaminar or non-turbulent<br />

conditions varies in direct proportion to the hydraulic gradient <strong>and</strong>,<br />

therefore, the pressure difference (hI - h2) causing the flow. This means that<br />

doubling the pressure difference will result in doubling the flow through the<br />

same cross-sectional area. By definition, the hydraulic gradient is seen to be<br />

equivalent to the slope of the water table for a water-table aquifer or of the<br />

piezometric surface for an artesian aquifer.<br />

Considering a vertical cross-section of an aquifer of unit width <strong>and</strong> having<br />

a total thickness, m, a hydraulic gradient, I, <strong>and</strong> an average coefficient of<br />

13


permeability, P, we see from equation (2.3) that the rate of flow, q, through<br />

this cross section is given by<br />

q=PmI (2.4)<br />

<strong>The</strong> product Pm of equation (2.4) is termed the coejficient of transntissi-<br />

bility or transmissivity, T, OI the aquifer. By further considering that the total<br />

width of the aquifer is W, then the rate of flow, Q, through a vertical<br />

cross-section of the aquifer is given by<br />

Q=qW=TIW (2.5)<br />

<strong>The</strong> coej@ient of trunsmissibility is, therefore, defined as the rate of flow<br />

through a vertical cross-section of an aquifer of unit width <strong>and</strong> whose height<br />

is the total thickness of the aquifer when the hydraulic gradient is unity. It is<br />

expressed in gallons per day per foot (gpd/ft) <strong>and</strong> is equivalent to the product<br />

of the coefficient of permeability <strong>and</strong> the thickness of the aquifer.<br />

Factors Affecting Permeability<br />

Porosity is an important factor affecting the permeability <strong>and</strong>, therefore,<br />

the capacity of an aquifer for yielding water. This is clearly evident since an<br />

aquifer can yield only a portion of the water that it contains <strong>and</strong> the higher<br />

the porosity, the greater is the volume of water that can be stored. Porosity<br />

must, however, be considered together with other related factors such as<br />

particle size, arrangement <strong>and</strong> distribution, continuity of pores, <strong>and</strong> forma-<br />

t ion stratification.<br />

<strong>The</strong> volume of voids or pores associated with the closest packing of<br />

uniformly&zed spheres (Fig. 2.7) will represent the same percentage of the<br />

total volume (solids <strong>and</strong> voids) whether the spheres were all of tennis ball size<br />

or all l/l000 inch in diameter. However, the smaller pores between the latter<br />

spheres would offer greater resistance to flow <strong>and</strong>, therefore, cause a decrease<br />

Fii. 2.7 UNIFORMLY SIZED<br />

SPHERES PACKED IN<br />

RHOMBOHEDRAL ARRAY.<br />

14<br />

Fig. 2.8 UNIFORMLY SIZED<br />

SPHERES PACKED IN CU-<br />

BICAL ARRAY.


in permeability even though the porosity is the same.<br />

<strong>The</strong> packing of tile spheres displajred in Fig. 2.7 is referred to as the<br />

rhombohedral packing. <strong>The</strong> porosity for such a packing can be shown to be<br />

0.26 or 26 percent. <strong>The</strong> spheres may also assume a cubical array as shown in<br />

Fig. 2.8 for which the porosity is 0.476 or 47.6 percent. <strong>The</strong>se porosities<br />

apply only to perfectly spherical particles <strong>and</strong> are included here to give the<br />

order of magnitude of the porosities that naturally occurring uniform s<strong>and</strong>s<br />

<strong>and</strong> gravels may approach. A loose uniform s<strong>and</strong> may, for example. have a<br />

porosity of 46 percent. Clays, on the other h<strong>and</strong>, exhibit much fligher<br />

porosities ranging from about 37 percent for stiff glacial clays to as high as 84<br />

percent for soft bentonite clays.<br />

Consideration of the effects of particle size <strong>and</strong> arrangement on<br />

permeability would be incomplete without simultaneously considering the<br />

effect of particle distibution or grading. A uniformly graded s<strong>and</strong>, that is,<br />

one in which all the particles are about the same size, wilt have a higher<br />

porosity <strong>and</strong> permeability than a<br />

less uniform s<strong>and</strong> <strong>and</strong> gravel mix-<br />

ture. This is so because the finer<br />

s<strong>and</strong> fills the openings between the<br />

gravel particles resulting in a more<br />

compact arrangement <strong>and</strong> fess pore<br />

volume (Fig. 2.9). Here, then, is an<br />

example of a finer material having a<br />

higher permeability than a coarser<br />

one due to the modifying effect of<br />

particle distribution.<br />

Flow cannot take place through<br />

porous material unless the passages<br />

Fig. 2.9 NON-UNIFORM MI XT URE<br />

OF SAND AND GRAVEL in the material are interconnected,<br />

WITH LOW POROSITY AND that is to say, there is continuity of<br />

PERh%tBII.ITY.<br />

the pores. Since permeability is a<br />

measure of the rate of flow under stated conditions through porous material,<br />

then a reduction in the continuity of the pores would result in a reduction in<br />

the permeability of the material. Such a reduction could be caused by silt,<br />

clay, or other cementing materials partially or completely filiing the pores in<br />

a s<strong>and</strong>, thus making it almost impervious.<br />

An aquifer is said to be stratiflied when it consists of different layers of<br />

fine s<strong>and</strong>, coarse s<strong>and</strong>, or s<strong>and</strong> <strong>and</strong> gravel. Most aquifers are stratified. While<br />

some strata contain silt <strong>and</strong> clay, others are relatively free from these<br />

cementing materials <strong>and</strong> are said to be clean. Where stratification is such that<br />

even a thin layer of clay separates two layers of clean s<strong>and</strong>, this results in the<br />

cutting off of the vertical movement of water between the s<strong>and</strong>s. Permeability<br />

may also vary from layer to layer in a stratified aquifer.<br />

A brief discussion on the measurement of permeability is to be found in<br />

Appendix A.<br />

15


Flow Toward <strong>Well</strong>s<br />

Converging j&w: When a well is at rest, that is, when there is no flow<br />

taking place from it, the water pressure within the well is the same as that in<br />

the formation outside the well. <strong>The</strong> level at which water st<strong>and</strong>s within the<br />

well is known as the static water level. This level coincides with the water<br />

table for a water-table aquifer or the piezometric surface for an artesian<br />

aquifer. Should the pressure be lowered within the well, by a pump for<br />

example, then tire greater pressure in the aquifer on the outside of the well<br />

would force water into the well <strong>and</strong> flak thereby results. This lowering of the<br />

pressure within the well is also acz$ *nanied by a lowering of the water level<br />

in <strong>and</strong> around the well. <strong>Water</strong> fl,j~ Through the aquifer to the well from all<br />

directions in what is known as ~0 ergingflow. This flow may be considered<br />

to take place through successit lindrical sections which become smaller<br />

<strong>and</strong> smaller as the we!1 is ap y’ ied (Fig. 2.10). This means that the area<br />

across which t&e flow takes r also becomes successively smaller as the<br />

R, -2R, A, = 2A2<br />

v, ‘2V,<br />

Fig. 2.10 F L 0 W CONVERGES TO-<br />

WARD A WELL, PASSING<br />

THROUGH IMAGINARY<br />

CYLINDRKAL SURFACES<br />

THAT ARE SUCCESSIVELY<br />

SMALLER AS THE WELL IS<br />

APPROACHED.<br />

well is approached. With the same<br />

quantity of water flowing across<br />

these sections, it follows from equa-<br />

tion (2.3) that the velocity in-<br />

creases as the area becomes smaller.<br />

Darcy’s Law, equation (2.2),<br />

tells us that the hydraulic gradient<br />

varies in direct proportion to the<br />

velocity. <strong>The</strong> increasing velocity to-<br />

wards the well is, therefore, ac-<br />

companied by an increasing hy-<br />

draulic gradient. Stated in other<br />

terms, the water surface or the<br />

piezometric surface develops an in-<br />

creasingly steeper slope toward the<br />

well. In an aquifer of uniform shape<br />

<strong>and</strong> texture, the depression of the<br />

water table or piezonetric surface<br />

in the vicinity of a pumped or<br />

freely flowing well takes the form<br />

of an inverted cone. This cone,<br />

known as the cone of depression<br />

(Fig. 2.1 l), has its apex at the water level in the well during pumping, <strong>and</strong> its<br />

base at the static water level. <strong>The</strong> water level in the well during pumping is<br />

known as the pumping water level. <strong>The</strong> difference in levels between the static<br />

water level <strong>and</strong> the surface of the cone of depression is known as the<br />

drawdown. Drawdown, therefore, increases from zero at the outer limits of<br />

the cone of depression to a maximum in the pumped weft. <strong>The</strong> radius of<br />

influence is the distance from the center of the well to the outer limit of the<br />

cone of depression.<br />

Fig. 2.12 shows how the transmissibility of an aquifer affects the shape of<br />

the cone of depression. <strong>The</strong> cone is deep, with steep sides, a large drawdown,<br />

16


-- Rodlus of Influence --+<br />

Static water level<br />

_------ --<br />

.--<br />

T<br />

Drowdown<br />

in we8<br />

C--<strong>Well</strong> Screen<br />

Fig. 2.11 CONE OF DEPRESSION IN<br />

VICINITY OF PUMPED<br />

WELL.<br />

FRadius =IS,OCO ft--<br />

<strong>and</strong> a small radius ot‘ influence<br />

when the aquifer transmissibility is<br />

low. With a high transmissibility,<br />

the cone is wide <strong>and</strong> shallow, rhe<br />

drawdown being small, <strong>and</strong> the<br />

radius of influence large.<br />

Rechg~ md bortndar-y ejfects:<br />

When pumping commences at ‘I<br />

well. the initial quantity of water<br />

discharged comes from the aquifer<br />

storage immediately surrounding<br />

the well. <strong>The</strong> cbne of depression is<br />

then small. As pumping continues,<br />

the cone exp<strong>and</strong>s to meet the in-<br />

creasing dem<strong>and</strong> for water from the<br />

aquifer storage. <strong>The</strong> radius of in-<br />

fluence increases <strong>and</strong>, with it, the<br />

drawdown in the well in order to<br />

provide the additional pressure<br />

head required to move the water<br />

through correspondingly greater<br />

distances. If the rate of pumping is<br />

kept constant, then the rate of<br />

Transmissibility - IO.OCO gpd/ft<br />

Radius = 40,000 ft<br />

Transmissibi!ity - IOO.000 gpd/ft<br />

- -<br />

Fig. 2.12 EFFECT OF DIFFERING COEFFICIENTS OF TRANSMISSIRILITY UPON<br />

THE SHAPE, DEPTH AND EXTENT OF THE CONE c)F DEPRESSION,<br />

PUMPING RATE AND OTHER FACTORS BEING THC SAME IN BOTH<br />

CASES.<br />

17


expansion <strong>and</strong> deepening of the cone of depression decreases with time. This<br />

is illustrated in Fig. 2.13 where C1 , C2 <strong>and</strong> C3 represent cones of depression<br />

at hourly intervals. <strong>The</strong> hourly increases in radius of influence, R, <strong>and</strong><br />

drawdown, s, become smaller <strong>and</strong> smaller until the aquifer supplies a quantity<br />

of water equal to the pumping rate. <strong>The</strong> cone no longer exp<strong>and</strong>s or deepens<br />

<strong>and</strong> equilibrium is said to have been reached. This state may occur in any one<br />

or more of the following situations.<br />

Fig. 2.13 CHANGES IN RADIUS AND<br />

DEWTH OF CONE OF DE-<br />

PRESSION AFTER EQUAL<br />

INTERVALS OF TIME, AS-<br />

~I$W&ONShUUT PUMP-<br />

.<br />

1. <strong>The</strong> cone enlarges until it in-<br />

tercepts enough of the natural<br />

discharge from the aquifer to<br />

equal the pumping rate.<br />

2. <strong>The</strong> cone intercepts a body of<br />

surface water from which<br />

water enters the aquifer at a<br />

,rate equivalent to the pump-<br />

ing rate.<br />

3. Recharge equal to the pump-<br />

ing rate is received from pre-<br />

cipitation <strong>and</strong> vertical infiltra-<br />

tion within the radius of in-<br />

fluence.<br />

4. Recharge equal to the pump-<br />

ing rate is obtained by leak-<br />

age through adjacent forma-<br />

tions.<br />

Where the recharge rate is the same from all directions around the well the<br />

cone remains symmetrical (Fig. 2.12). If, however, it occurs main!y from one<br />

direction, as may be the case with a surface stream, then the surface of the<br />

cone is higher in the direction from which the recharge takes place than in<br />

other directions (Fig. 2.14). Conversely, the surface of the cone is relatively<br />

depressed in the direction of an imperrnea&le boundary intercepted by it (Fig.<br />

2.15). No recharge is obtained from such a boundary while that received from<br />

other directions maintains the higher levels in those directions. Recharge areas<br />

to aquifers, such as surface streams are, therefore, often referred to as positive<br />

boundaries while impermeable areas are known as negative boundaries.<br />

Mdtiple well system: Under some conditions the construction of a single<br />

large well may be either impractical or very costly while the installation of a<br />

group of small wells may be readily <strong>and</strong> economically accomplished. Factors<br />

such as the inaccessibility of the area to the heavy equipment required for<br />

drilling the large well <strong>and</strong> the high cost of transporting large diameter pipes to<br />

the site may be among the important considerations in a situation such as<br />

this. Small wells can be grouped in a proper pattern to give the equivalent<br />

performance of a much larger single well.<br />

<strong>The</strong> grouping of wells, however, presents problems due to interference<br />

among them when operating simultaneously. Interference between two or<br />

more wells occurs when their cones of depression overlap, thus reducing the<br />

18


Discharging well<br />

Fig. 2.14 SYMMETRY OF CONE OF DEPRESSION AFFECJ.‘ED BY RECHARGE<br />

FROM STREAM.<br />

r Discharging well<br />

Fig. 2.15 CONE OF DEPRESSION IN VICINITY OF IMPERMEABLE BOUNDARY.<br />

19


yield of the individual wells (Fig . 2.16). <strong>The</strong> drawdowrl at any point on tile<br />

composite cone of depression is equal to the sum of ihe drawdowns ai that<br />

point due to each of the wells being pumped separately. In particular, the<br />

drawdown for ;I specific disclltlrge ill<br />

Static water level I -_ a well affected by interference is<br />

greater fllA11 llit unaffected value b?<br />

the amount of drawdown ait that<br />

well contributed by the interfering<br />

wells. In other words, the discharge<br />

per unit of drawdown commonly<br />

called the specific capacit), of the<br />

well is reduced. This means that<br />

pumping must take place from a<br />

greater depth in the well, at a greater<br />

cost, to produce the same qaan:ity<br />

of water from the well if it were not<br />

Fig. 2.16 INTERFERENCE BETWEEN subject to interference.<br />

ADJACENT WELLS TAi’-<br />

PING THE SAME AQUIFER. Ideally, the solution would be to<br />

space the wells far enough apart to<br />

avoid the mutual interference of one ok the other. Very often this is not<br />

practic,tJ for economic reasons <strong>and</strong> the wells are spaced far enough apart. not<br />

to eliminate interference. but to reduce it to acceptable proportions. For<br />

wells use3 for water supply purposes, spacings of 115 to 50 feet between wells<br />

have bee11 found to be satisfactory. Spacings may be less in fine s<strong>and</strong><br />

formations, in thin aquifers or when the drawdowrt is not likely to exceed 5<br />

feet. Greater spacings may be used where the depth <strong>and</strong> thickness of the<br />

aquifer are such as to permit the use of screen lengths in excess of IO feet.<br />

<strong>The</strong>re arc many patterns which may be used when grouping weils (Fig.<br />

2.17). Where the aquifer extends considerable distances in all directions from<br />

the site of a proposed wetI field, the most desirable arrangement is one in<br />

which the wells are locaf!:d at equal distances on the circumference of a<br />

circle. This pattern equalizes the amount of interference suffered by each<br />

well. It should be obvious that a well placed in the center of such a ring of<br />

wells would suffer greater interference than any of the others when all are<br />

pumped simultaneously. Such centrally placed wells should be avoided in well<br />

field layouts.<br />

Where a known source of recharge exists near a proposed site the wells<br />

may be located m a semi-circle or along a line roughly parallel to the source.<br />

<strong>The</strong> latter arrangement is the one often used to induce recharge to an aquifer<br />

from an adjacent stream with which it is connected. This is a very useful<br />

technique in providing an adequate water supply to a small community long<br />

after the stream level becomes so low that only an inadequate quantity of<br />

poor quality water can be obtained directly from the stream. This is possible<br />

since the use of wells perrnirs the withdrawal of water from the permeable<br />

river bed <strong>and</strong> the quality is enhanced by the filtering action of the aquifer<br />

materials.<br />

‘0


Fig. 2.17 LAI’OUT PATTERNS FOR MULTIPLE WELL SYSTEMS USED AS WATER<br />

SUPPLY SOURCES. CENTRALLY LOCATED PUhlP EQUAL.iZES SUCTION<br />

LIFT.<br />

I<br />

<strong>Well</strong>-point System<br />

Saturated s<strong>and</strong> A<br />

Sub-soil<br />

<strong>Water</strong> level<br />

while pumping<br />

Fig. 2.18 WELL-POINT DEWATERING SYSTEM.<br />

‘I<br />

ID)<br />

\ ‘\ \


Multiple well or well-point systems are also used OJI engineering construo-<br />

tion sites for de-watering purposes, i.e. to extract water from an area to<br />

provide dry working conditions (Fig. 2.18). <strong>The</strong> significant difference<br />

between this use <strong>and</strong> that for water supplies is the fact that it is JIOW<br />

important to create interference in order to lower water levels as much as<br />

possible. Closer well spacings than those recommended for water supply<br />

purposes are, therefore, necessary. <strong>Well</strong> spacings for de-watering systems<br />

usually range from 2 to 5 feet depending upon the permeability of the<br />

saturated s<strong>and</strong>, the depth to which the water table is to be lowered <strong>and</strong> the<br />

depth to which the well points can be installed in the formation. It is<br />

important to note that the de-watering process may require as much as a day<br />

of pumping before excavation can begin <strong>and</strong> must be continued throughout<br />

the excavation. Nevertheless, de-watering has often proved more economical<br />

than pumping from within a sheet pile surrounded working area.<br />

QUALITY OF GROUND WATER<br />

Generally, the openings through which water flows in the ground are very<br />

small. This considerably restricts the rate of flow while at the same time<br />

providing a filtering action against particles originally in suspension in the<br />

water. <strong>The</strong>se properties, it will be seen, considerably affect the physical,<br />

chemical, <strong>and</strong> microbiological qualities of ground water.<br />

Physical Quality<br />

Physically, ground water is generally clear, colorless, with little or no<br />

suspended matter, <strong>and</strong> has a relatively constant temperature. This is<br />

attributable to its history of slow percolation through the ground <strong>and</strong> the<br />

resulting effects earlier mentioned. In direct contrast, surface waters are very<br />

often turbid <strong>and</strong> contain considerable quantiiies of suspended matter,<br />

particularly when these waters are found near populous areas. Surface walers<br />

are also subject to wide variations of iemperature. From the physical point of<br />

view, ground water is, therefore, more readily usable than surface water,<br />

seldom requiring treatment before use. <strong>The</strong> exceptions are those ground<br />

waters which are hydraulically connected to nearby surface waters through<br />

large openings such as fissures <strong>and</strong> solution chamlels <strong>and</strong> the interstices of<br />

some gravels. <strong>The</strong>se openings may permit suspended matter to enter into the<br />

aquifer. In such cases, tastes <strong>and</strong> odors from decaying vegetation may also be<br />

noticeable.<br />

Microbiological Quality<br />

Ground waters are generally free from the very minute organisms<br />

(microbes) which cause disease <strong>and</strong> which are normally present in large<br />

numbers in surface waters. This is another of the benefits that result from the<br />

slow filtering action provided as the water flows through the ground. Also,<br />

the lack of oxygen <strong>and</strong> nutrients in ground water makes it an unfavorable<br />

environment for disease-producing organisms to grow <strong>and</strong> multiply. <strong>The</strong><br />

exceptions to this rule are again provided by the fissures <strong>and</strong> solution<br />

channels found in some consolidated rocks <strong>and</strong> in those shallow s<strong>and</strong> <strong>and</strong><br />

73<br />

--


gravel aquifers where water is extracted in close proximity to pollution<br />

sources, such as privies <strong>and</strong> cesspools. This latter problem has been dealt with<br />

in more detail in Chapter 9, where the sanitary protection of ground-water<br />

supplies is discussed. Poor well construction can also result in the<br />

contamination of ground waters. <strong>The</strong> reader is referred to the section in<br />

Chapter 4 dealing with the sanitary protection of wells.<br />

<strong>The</strong> solution of the potable water supply problems of Nebraska City,<br />

Nebraska, U.S.A. in 1957 bears striking testimony to the benefits derived<br />

from percolation of water through the ground <strong>and</strong> the general advantages of’a<br />

ground-water supply over one from a surface source. For more than 100 years<br />

prior to 1957, Nebraska City depended upon the Missouri River for its<br />

domestic water supply. <strong>The</strong> quality of the water in the river deteriorated as<br />

the years went by due to the use of the river for sewage <strong>and</strong> other forms of<br />

waste disposal. To the old problems of high concentrations of suspended<br />

matter, dark coloration from decayed vegetation <strong>and</strong> highly variable<br />

temperatures (too warn in summer <strong>and</strong> too cold in winter) was added<br />

bacterial pollution. So bad was this sittration that the Missouri River, in this<br />

region, soon beczrre recognized as a virtual open sewer <strong>and</strong> the water no<br />

longer met the requirements of the United States Public Health Service<br />

Drinking Watei- St<strong>and</strong>ards for waters suitable to be treated for municipal use.<br />

<strong>The</strong> search for a new source of supply for Nebraska City led to the use of<br />

wells drilled into the s<strong>and</strong>s that underlie the flood plain of the Missouri River<br />

at depths up to 100 feet. <strong>Well</strong>s drilled a mere 75 feet from the river’s edge<br />

<strong>and</strong> drawing a considerable percentage of their water from the river yielded a<br />

very high quality, clear water that showed no evidence of bacterial pollution<br />

or noticeable temperature variation. <strong>The</strong> lessons of Nebraska City can be put<br />

to beneficiai use in many other areas of the world.<br />

Chemical Quality<br />

<strong>The</strong> chemical quality of ground water is also considerably influenced by its<br />

relatively slow rate of travel through the ground. <strong>Water</strong> has always been one<br />

of the best solvents known to man. Its relatively slow rate of percolation<br />

through the earth provides more than am


10 ppm of iron means that in every million pounds (or kilograms) c,i‘ the<br />

water examined there will be found 10 pounds (or kilograms) of iron.<br />

Another very common form of expression is that of milligrams per liter (mg/l<br />

or mg per 1) which is the number of milligrams of the mineral found in one<br />

liter of water. This latter unit differs so little from the former that ihey are,<br />

for all practical purposes, considered equal <strong>and</strong> are ~on~n~only used<br />

interchangeably.<br />

<strong>The</strong> following are among the more important chemical substances <strong>and</strong><br />

properties of ground waters which are of interest to the owners of small<br />

wells: iron, manganese, chloride, fluoride, nitrate, sulfate, hardness. total<br />

dissolved solids, pH, <strong>and</strong> dissolved gases such as oxygen, hydrogen sulfide,<br />

<strong>and</strong> carbon dioxide.<br />

Zrorz <strong>and</strong> nlarzgarlese are usually considered together because of their<br />

resemblances in chemical behavior <strong>and</strong> occurrence in ground water. It is<br />

important to note that iron <strong>and</strong> manganese, in the quantities usually found in<br />

ground water, are objectionable because of their nuisance values rather than<br />

as a threat to man’s health. <strong>The</strong>y both cause staining (reddish brown in the<br />

case of iron <strong>and</strong> black in the case of manganese) of plumbing fixtures <strong>and</strong><br />

clothes during laundering. Iron deposits may accumulate in well screens <strong>and</strong><br />

pipes, restricting the flow oi water through them. Iron-containing waters also<br />

have a characteristic taste which some people find unpleasant. Such waters,<br />

when first drawn from a tap or pump, may be clear <strong>and</strong> colorless, but upon<br />

allowing the water to st<strong>and</strong>, the iron settles out of solution giving a cloudy<br />

appearance to the water <strong>and</strong> later accumulating in the bottom as a<br />

rust-colored deposit.<br />

Chlorides occur in very high concentrations in sea water, usually of the<br />

order of 20,000 mg/l. Rainwater, however, contains much less than I mg/l of<br />

chloride. Aquifers containing large chioride concentrations are usually coastal<br />

ones directly connected to the sea or which were so connected some time in<br />

the past. Excessive pumping of wells in aquifers directly connected to the sea<br />

or to brackish-water rivers will cause these high chloride-containing waters to<br />

move into the otherwise fresh water zones of the aquifers. Expert technical<br />

advice should be sought on the possibility of such an occurrence.<br />

<strong>Water</strong> with a high chloride content usually has an unpleasant taste <strong>and</strong><br />

may be objectionable for some agricultural purposes. <strong>The</strong> level at which the<br />

taste is noticeable varies from person to person but is generally of the order<br />

of 350 mg/l. A great deal depends, however, on the extent to which people<br />

have been accustomed to using such waters. Animals usuaily can drink water<br />

with much more chloride than humans can tolerate. Cattle have, reportedly,<br />

been known to consume water with a chloride content ranging from 3000<br />

mg/l to 4000 mg/l.<br />

FZunride concentrations in ground water are usually small <strong>and</strong> mainly<br />

derived from the leaching of igneous rocks. Notable among the few cases of<br />

high concentrations is the reported 32 mg/l from a flowing well near San<br />

Simon, Arizona, U.S.A. High concentrations have also been reported in some<br />

parts of India, Pakistan <strong>and</strong> Africa.<br />

24


dissolved solids content would therefore be expected to present rhe taste,<br />

laxative <strong>and</strong> other problems associated with the individual minerals. Such<br />

waters are usually corrosive to well screens <strong>and</strong> other parts of the well<br />

structure.<br />

pH is a measure of the hydrogen ion ccncentration in water <strong>and</strong> indicates<br />

whether the water is acid or alkaline. It ranges in value from 0 to 14 with a<br />

value of 7 indicating a neutral water, values between 7 <strong>and</strong> 0 increasingly acid<br />

<strong>and</strong> between 7 <strong>and</strong> 14 increasingly alkaline waters. Most ground waters in the<br />

United States have pH values ranging fr0.m about 5.5 to 8. Determination of<br />

the pH value is important in the control of corrosion <strong>and</strong> many processes in<br />

water treatment.<br />

<strong>The</strong> dissolved ox-vgen content of ground wsters is usually low particularly<br />

in waters found at great depths. Oxygen speeds up the corrosive attack of<br />

water upon iron, steel, galvanized iron, <strong>and</strong> brass. <strong>The</strong> corrosive process is aLc,<br />

more rapid when the pH is low.<br />

Hydrogen sulfide is recognizable by its characteristic odor of rotten eggs.<br />

It is very often found in ground waters which also contain iron. In addition to<br />

the odor, which is noticeable at as low a concentration as 0.5 mg/l, hydrogen<br />

;r sulfide combines with oxygen to produce a corrosive condition in wells <strong>and</strong><br />

also combines with iron to form a scale deposit of iron sulfide in pipes. Most<br />

of the hydrogen sulfide can be removed from ground water by spraying it<br />

into the air or allowing it to cascade in thin layers over a series of trays.<br />

Carbon dioxide enters water in appreciable quantities as the water<br />

percolates through soil in which plants are growing. Dissolved in water, it<br />

forms carbonic acid which, together with the carbonates <strong>and</strong> bicarbonates,<br />

controls the pH value of most ground waters. A reduction of pressure, such as<br />

caused by the pumping of a well, results in the escape of carbon dioxide <strong>and</strong><br />

an increase in the pH value of the water. Testing of ground-water samples for<br />

carbon dioxide content <strong>and</strong> pH, therefore, requires the use of special<br />

techniques <strong>and</strong> should be done at the well site. <strong>The</strong> escape of carbon dioxide<br />

from a water may also he accompanied by the settling out of calcium<br />

carbonate deposits.<br />

While the above list includes those chemical substances that are likely to<br />

be of greatest general concern to owners of small wells, it is by no means an<br />

exhaustive one nor intended to be such. Conditions peculiar to specific areas<br />

may require analyses of ground waters for other substances. <strong>The</strong> group of<br />

elements often referred to as the trace elements because of the very low<br />

concentrations in which they are usually found in water are here worth<br />

mentioning. Among these are arsenic, barium, cadmium, chromium, lead <strong>and</strong><br />

selenium, all of which are considered toxic to man at very low levels of intake<br />

(the order of a fraction of 1 mg/l). Since the rate of passage of some of these<br />

elements through the body is very slow, the effects of repeated doses are<br />

additive <strong>and</strong> chronic poisoning occurs.<br />

Trace elements generally are not present in objectionable concentrations in<br />

ground waters but may be so in a few specific areas. It has been reported for<br />

example, that arsenic has been found in sufficiently high concentrations in<br />

26


ground waters in some parts of Argentina <strong>and</strong> Mexico to be considered<br />

injurious to health. Problems are most likely to arise in areas where waste<br />

discharges from industries, such as electro-plating, <strong>and</strong> overl<strong>and</strong> runoff<br />

containing high concentrations of pesticides (insecticides <strong>and</strong> herbicides)<br />

enter aquifers.<br />

‘<strong>The</strong> presence of these trace elements in drinking water are generally not<br />

detectable by taste or smell or physical appearance of the water. Proper<br />

chemical analyses are required for their detection. Health departments,<br />

laboratories, geological survey departments, <strong>and</strong> other competent agencies<br />

should be consulted in areas where waste disposal is likely to increase the<br />

natural content of these elements in ground water or where the natural levels<br />

are likely to be high because of the local geology.<br />

27


<strong>Water</strong> can be found almost anywhere under the earth’s surface. <strong>The</strong>re is,<br />

however, much more to ground-water exploration than the mere location of<br />

subsurface water. <strong>The</strong> water must be in large quantities, capable of sustained<br />

flow to wells over long periods 7-t reasonable rates, <strong>and</strong> of good quality. To be<br />

reliable, ground-water explorat!on must combine scientific knowledge with<br />

experience <strong>and</strong> common sense. It cannot be achieved by the mere waving of a<br />

magic forked stick as may be claimed by those who practrce what is variously<br />

referred to as water witching, water dowsing, or water divining.<br />

Finding the right location for a well that produces a good, steady water<br />

supply all the year round is usually the job of scientists trained in hydrology.<br />

<strong>The</strong>se scientists are called hydrologists. <strong>The</strong>ir help may be sought from<br />

geological survey departments, governmental <strong>and</strong> private engineering organi-<br />

zations. <strong>and</strong> universities if <strong>and</strong> when available. <strong>The</strong>se experts should always be<br />

consulted for large scale ground-water development schemes because of the<br />

great capital expenditures usually involved. However, it should be apparent<br />

from the remaining sections of this chapter that a sufficient number of the<br />

tools of the hydrologist is based upon. the application of common sense,<br />

intelligence <strong>and</strong> good judgement to permit their reasonably successful use by<br />

the average individual interested in the location of small wells. <strong>The</strong><br />

interpretation of geologic data may present problems though, with some help,<br />

these need not be totally insurmountable to some of our readers. <strong>The</strong> use of<br />

well inventories <strong>and</strong> surface evidence of ground water location should be<br />

much less difficult <strong>and</strong> find greater general application.<br />

<strong>The</strong> following sections describe the simpler tools of the hydrologist <strong>and</strong> his<br />

use of them. <strong>The</strong> more sophisticated methods of exploration involving the use<br />

of geophysics are considered beyond the scope of this manual <strong>and</strong>, therefore,<br />

have been excluded. It is sufficient to note that they are available to the<br />

hydrologist to provide him with additional information on which to base his<br />

selection.<br />

GEOLOGIC DATA<br />

Before visiting the area to be investigated, the hydrologist seeks out <strong>and</strong><br />

studies all available geologic data relating to it. <strong>The</strong>se would include geologic<br />

maps, cross-sections <strong>and</strong> aerial photographs.


Geologic Maps<br />

Geologic maps, of which Fig. 3.1 is an example, show where the different<br />

rock formations, consolidated or unconsolidated, come to the l<strong>and</strong> surface or<br />

outcrop, their strike or the direction in which they lie, <strong>and</strong> their dip or the<br />

angle at which they are inclined to the horizontal. Other useful information<br />

Legend<br />

Alluvwm, Includes<br />

unconsolidated s<strong>and</strong>,<br />

grovel, slit <strong>and</strong> cloy<br />

Char formotlon<br />

hmestone<br />

j-q<br />

Looml;bremotwx<br />

I<br />

Sontos formotlon<br />

shale<br />

I<br />

Osoge hmest0ne<br />

I<br />

hternom s<strong>and</strong>stone<br />

Strike <strong>and</strong> Dip<br />

.<br />

Test hole<br />

Fig. 3.1 EXAMPLE OF A GEOLOGIC MAP SHOWING TEST HOLE LOCATIONS.<br />

shown would include the location of faults <strong>and</strong> contour lines indicating depth<br />

to bedrock throughout the area. Faults are lines of fracture about which the<br />

rock formations are relatively dislocated. <strong>The</strong>y are the result of forces acting<br />

in the earth to cause lateral thrust, slippage or uplift. <strong>The</strong> hydrologist can<br />

determine the location <strong>and</strong> area1 extent of aquifers from the type <strong>and</strong><br />

location of rock outcrops <strong>and</strong> the location of faults. Faults are also likely<br />

sites for the occurrence of springs. <strong>The</strong> width of the outcrop <strong>and</strong> angle of dip<br />

indicate to him the approximate thickness of an aquifer <strong>and</strong> the depths to<br />

which it can be found. <strong>The</strong> combination of strike <strong>and</strong> dip tell him in which<br />

direction he should locate a well to obtain the maximum thickness of the<br />

aquifer. <strong>The</strong> surface outcrops also indicate the possible areas of recharge to an<br />

aquifer <strong>and</strong>, by deduction, the direction of flow in the aquifer. <strong>The</strong> bedrock<br />

contours indicate the maximum depth to which d well should be drilled in<br />

search of water.<br />

Geologic Cross-Sections<br />

Geologic cross-sections provide some of the main clues to the ground-<br />

water conditions of a locality. <strong>The</strong>y indicate the character, thickness, <strong>and</strong><br />

succession of underlying formations <strong>and</strong>, therefore, the depths <strong>and</strong> thick-<br />

nesses of existing aquifers. <strong>The</strong> main sources of information for the<br />

preparation of these sections are well records <strong>and</strong> natural exposures where the<br />

rock faces have not been greatly altered by weathering. Examples of the latter


may be seen in some river valleys <strong>and</strong> gorges. <strong>The</strong>se sections may also indicate<br />

whether water-table or artesian conditions exist in an aquifer. <strong>The</strong> cross-<br />

sections of Fig. 3.2, drawn from the geologic map of Fig. 3.1, illustrate many<br />

of the important features mentioned above.<br />

Fig. 3.2 GEOLOGIC CROSSSECTIONS FROM THE MAP OF FIG. 3.1.<br />

<strong>Water</strong> surface<br />

Aerial Photographs<br />

Aerial photographs, skillfully interpreted, provide valuable information on<br />

terrain characteristics which have considerable bearing on the occurrences of<br />

ground water. Features which indicate subsurface conditions such as<br />

vegetation, l<strong>and</strong> form <strong>and</strong> use, erosion, drainage patterns, terraces, alluvial<br />

plains, <strong>and</strong> gravel pits are apparent on aerial photographs. <strong>The</strong> skillful<br />

interpreter of aerial photographs can determine the most promising areas for<br />

ground-water development.<br />

INVENTORY OF EXISTING WELLS<br />

<strong>The</strong> hydrologist next makes a study of all available information on existing<br />

wells.<br />

<strong>Well</strong> logs which are records of information pertaining to the drilling <strong>and</strong><br />

construction of wells would be the main sources of information. From these<br />

logs he may obtain such information as the location <strong>and</strong> depth of the well;<br />

30


depth. thickness. <strong>and</strong> description of rock fornrarions penetrated: water level<br />

variations as successive strata are penetrated; yields from water-bearing<br />

formations penetrated <strong>and</strong> the corresponding drawdowns; the form of well<br />

construction; <strong>and</strong> the vield <strong>and</strong> drawdown of the well upon completion.<br />

Many drilling orgsnizaiions also keep samples of rocks from the various<br />

formations penetrated. Associated with the well log should be a record of the<br />

water quality (physical <strong>and</strong> chemical characteristics) of water-bearing strata<br />

encountered. Of further interest to the hydrologist would be records of any<br />

tests making use of the well or materials from the well to determine the<br />

hydraulic characteristics such as permeability <strong>and</strong> transmissibility of the<br />

aquifer. To compiete the picture. he would be interested in records of the<br />

v&ations in yield <strong>and</strong> water quality <strong>and</strong> a history of any problems associated<br />

with the well since its completion. <strong>The</strong> hydrologist may wish to have new<br />

checks made on some aspecrs of ihese records sush as rhe water quality <strong>and</strong><br />

yield.<br />

A!1 these records may not be available from any single source. In addition<br />

to the various agencies already mentioned. the hydrologist may have to<br />

consult well owners <strong>and</strong> drilling organizations.<br />

With records from a sufficient number of wells, the hydrologist would now<br />

be in 3 position to make a contour map of the water-table or upper surface of<br />

the zone of saturation. To do this. he uses the measured depths from Iihnd<br />

surface to the water table at wells <strong>and</strong> the height of the l<strong>and</strong> surf’ace relative<br />

to sea level which he obtains front topographic maps or a site survey. He then<br />

connects ail points of equa! elevation of the water table on a map. This<br />

contour map shows the shape of the water surface. It is a very important map<br />

in tltat it shows not only the depth below which ground water is stored but<br />

also, from the slope of the water table, the direction in which the water<br />

moves.<br />

SURFACE EVIDENCE<br />

<strong>The</strong> hydrologist is now ready to visit the area <strong>and</strong> take a closer look at any<br />

surface evidence of ground-water occurrence. He will exantine in greater<br />

detail the important superficial features hc had noted on the topographic<br />

maps <strong>and</strong> aerial photographs. Among the features that would provide valuable<br />

clues would be l<strong>and</strong> forms, stream patterns. springs, lakes, <strong>and</strong> vegetation.<br />

Ground water is likely to occur in larger quantities under valleys than<br />

under hills. Valley fills containing rock waste washed down from mountain<br />

sides are often found to be very productive aquifers. <strong>The</strong> material may have<br />

been deposited by streams or sheet floods with some of the finer material<br />

getting into lakes to form stratified lake beds. Some of these deposits may<br />

afso be found to have been transported by wind <strong>and</strong> redeposited as s<strong>and</strong><br />

dunes. All these <strong>and</strong> other factors intluence the rate at which the valley fill<br />

will yield water. Coastal terraces, formed by the sinking <strong>and</strong> raising of coastal<br />

areas relative to sea level in the geologic past. <strong>and</strong> coastal <strong>and</strong> river plains are<br />

other l<strong>and</strong> forms that wouid indicaie the presence of good aquifers.<br />

Any evidence of surface water such as streams. springs. seeps, swamps, or<br />

lakes is a good indication of the presence of some ground water, though not<br />

31


necessarily in usable quantity. <strong>The</strong> s<strong>and</strong> <strong>and</strong> gravel deposits found in river<br />

beds may very often ext .end laterally into the river bdanks which may be<br />

penetrated by shallow. highly product&e wells.<br />

Vegetation, particularly water-loving types when found in arid regions,<br />

provides good clues to shallow ground-water occurrence. Evidence of<br />

unusually thick overgrowth is generally a sure pointer to the presence of<br />

streams <strong>and</strong> other surface waters, the vicinities of which would be likely sites<br />

for ground-water investigations. Fig. 3.3 demonstrates the application of<br />

some of the principles outlined above in the selection of possible well sites.<br />

Fig. 3.3 SURFACE EVIDENCE OF GROUND-WATER OCCURRENCE. (Adapted<br />

from Fig. 4, Wafer Supply For Rural Areas And Small Communities. WHO<br />

Monograph Series No. 4.., 1959.)<br />

I - Dense vegetation indicating possible shallow water table <strong>and</strong> proximity<br />

to surface stream.<br />

2 - River plains: possible sites for wells in water-table aquifer.<br />

3 - Flowing spring where ground water outcrops. Springs may also be<br />

found at the foot of hills <strong>and</strong> river banks.<br />

4 - River beds cut into water-bearing s<strong>and</strong> formation. Indicate possibility<br />

of river banks as good well sites.<br />

In many areas, some of the records, maps, <strong>and</strong> other relevant information<br />

so far discussed will not be available to the hydrologist. Where the size of the<br />

project warrants it, he will arrange to fill in the information as far as is<br />

practicabie. in other situations, very likely the case for the size of weiis herein<br />

considered, he will simply use his best judgement based on the readily<br />

available information.<br />

32


CHAPTER 4<br />

Generally, the aim of engineering design is to achieve the best possible<br />

combination of performance, useful life <strong>and</strong> reasonable cost. <strong>The</strong> designer of<br />

small wells will often find that his optimum solutions involve a variety of<br />

compromises <strong>and</strong> that he must adopt a flexible approach to each problem.<br />

Among these compromises is the need to sacrifice performance or efficiency<br />

in order to reduce costs. For example, in the situation where a small yield is<br />

required from a very thick <strong>and</strong> permeable aquifer, a less efficient type of<br />

intake section such as slotted pipe may justifiably be used in a small well to<br />

save the extra cost of a more efficient factory-manufactured screen. Here, the<br />

limited yield relative to the highly productive nature of the aquifer makes<br />

cost <strong>and</strong> availability of funds assume a more important role than hydraulic<br />

efficiency. It may also be considered worthwhile to compromise the useful<br />

life of a small well with respect to its cost. With stainless steel <strong>and</strong> other<br />

non-corrosive materials costing two to three times as much as ordinary steel, a<br />

designer may use well casing of the latter mat,,rial under corrosive conditions,<br />

fully expecting to replace it, perhaps in one-half the time he would have had<br />

he used stainless steel. He may very well have based his decision on the fact<br />

that at the end of the shorter useful life, extra funds might be available for a<br />

replacement of the existing well.<br />

For design purposes, a well to be constructed in unconsolidated materials<br />

may be considered as consisting of two main parts. <strong>The</strong> upper part or cased<br />

section of the well serves as housing for the pumping equipment <strong>and</strong> as a<br />

vertical conduit through which water flows from the aquifer to the pump or<br />

to the discharge pipe of a flowing artesian well. It is usually of water-tight<br />

construction <strong>and</strong> extends downward from the surface to the impervious<br />

formation immediately above an artesian aquifer or to a safe depth below the<br />

anticipated pumping water level (see the later section of this chapter dealing<br />

with sanitary protection of wells). It is also referred IO as the well casing.<br />

<strong>The</strong> lower or intake section of the well is that part of the well st-ucture<br />

where water from the aquifer enters the well. <strong>The</strong> intake section may be<br />

simply the open lower end of the well casing, though this would be a most<br />

unsatisfactory arrangement in unconsolidated formations. <strong>The</strong> disadvantages<br />

are the large well diameters required for the natural seepage of water into the<br />

well <strong>and</strong> the tendency for aquifer material to heave into the well casing<br />

as the well is being pumped. A screening devze known as a well screen<br />

should be used instead. Such a screen permits the use of techniques aimed at<br />

increasing the natural seepage rate into the we!! (see later section on well<br />

33


development), thus making a much smaller well practicable. In addition to<br />

ensuring the relatively free entry of water into the well at low velocity, the<br />

screen must provide structural support against the collapse of the unconsoli-<br />

dated formation material <strong>and</strong> prevent the entry of this material with water<br />

into the well.<br />

CASED SECTION<br />

<strong>The</strong> selection of the well casing dimerer is usually controlled by the type<br />

<strong>and</strong> size of the pump that is expected to be required for the desired of<br />

potential yield of the well. <strong>The</strong> well casing must be large enough to<br />

accommodate the pump with s)lfficient clearance for easy installation <strong>and</strong><br />

efficient opera?ion. For larger wells, such as those used for municipal <strong>and</strong><br />

industrial suppiies, the casing diameter should be chosen as two nominal sizes<br />

(never :ess than one nominal size) larger than that of the pump bowls. For<br />

wells of 4 inches <strong>and</strong> less in diameter it is satisfactory to select a casing<br />

diameter which is one nominal size larger than that of the pump bowls, pump<br />

cylinder or pump body. <strong>The</strong> above assumes the use of a deep-well type of<br />

pump which is usually suspended by pipe column <strong>and</strong>/or shaft within the well<br />

casing. A pump having a bowl diameter (see Fig. 8.11) greater than 3 inches<br />

should not, according to this rule, be installed in a $-inch diameter casing.<br />

In small wells where pumping water levels below ground surface are known<br />

to be within the practical suction limits (15 feet or less) of most surface-type<br />

pumps, such pumps are either directly connected to the top of the well casing<br />

or connected to a suction pipe suspended inside the well casing. <strong>The</strong> well<br />

casing diameter may then be selected in relation to the diameter of the<br />

suction or inlet of the pump, bearing in mind that it is not good practice to<br />

restrict the suction capacity of the pump by using pipe of a smaller diameter<br />

than that of the suction side of the pump.<br />

In larger <strong>and</strong> deeper wells than those being considered, it is sometimes<br />

advantageous for economic <strong>and</strong> other reasons to reduce the casing diameter at<br />

levels below the lowest anticipated pumping depth. This is done by<br />

telescoping one or more smaller sized casing sections through the uppermost<br />

one. This saves the extra cost of extending the large diameter casing all the<br />

way down to the aquifer when a smaller size of pipe would be sufficient to<br />

accommodate the anticipated flow with reasonable head loss. However, there<br />

is little justification for this type of design in wells of 4 inches <strong>and</strong> less in<br />

diameter <strong>and</strong> not more than 100 feet deep.<br />

INTAKE SECTION<br />

Type <strong>and</strong> Construction of Screen<br />

<strong>The</strong> single factor with greatest influence on the efficient performance of a<br />

well is the design <strong>and</strong> construction of the well screen. A properly designed<br />

screen combines a high percentage of open area for relatively unobstructed<br />

flow into the well with sufficient strength to resist the forces to which the<br />

screen may be subjected both during <strong>and</strong> after installation in the well. <strong>The</strong><br />

screen openings should preferably be shaped so as to facilitate flow into the<br />

well while making it difficult for small particles to become permanently<br />

34


lodged in them <strong>and</strong> thus restrict flow. A discussion of various types of WPII<br />

screens <strong>and</strong> their uses is presented in the following paragraphs.<br />

<strong>The</strong> corrtimmts-slot type of well screen shown in Fig. 4. I is made with<br />

cold-drawn wire, appro,ximately triangular in section, wound spirally around a<br />

circular array oflongitcldinal rods. <strong>The</strong> wire is welded to the rods at all points<br />

Fig.4.1 FABRICATION OF A CONTINUOUS-SLOT TYPE OF WELL SCREEN.<br />

at which they cross. <strong>The</strong> resulting cylindrical well screen becomes a one-peice.<br />

rigid unit.<br />

<strong>The</strong> stronger the material used in construction, the smaller would be the<br />

dimensions of the wire rods <strong>and</strong> hence the greater the ratio of open area to<br />

solid area of the screen surface. <strong>The</strong>se screens are being made of metals such<br />

as galvanized iron, steel, stainless steel <strong>and</strong> various types of brass. Experi-<br />

.ments are also in progress with the use of plastic materials.<br />

<strong>The</strong> percentage of open area is the factor exerting the greatest influence on<br />

the efficiency of a screen. As will be shown later, the size of the well screen<br />

opening is determined from the size of the particles of the material<br />

composing the aquifer. With this size fixed, the aim of screen design is to<br />

obtain the maximum possible total open area in a given length of screen, <strong>The</strong><br />

greater the total open area, the lesser is the resistance to flow into the well.<br />

<strong>The</strong> entrance velocity through the larger intake area is also lower <strong>and</strong> so is the<br />

resulting head loss for flow through the screen. Hence we have a more<br />

efficient well screen. <strong>The</strong> greater the percentage of open area in a screen, the<br />

greater is the total open area in a given length of screen.<br />

Looking at it in another way, the greater the percentage open area of a<br />

screen, the shorter is the length of screen required for a given rate of flow at a<br />

given velocity. This means that a saving in construction costs can be made<br />

throtigh the use of a shorter length of screen. <strong>The</strong> continuous-slot type of<br />

screen provides more intake area per square foot of screen surface or per unit<br />

length of screen than any other known type <strong>and</strong>, therefore, can result in<br />

savings when used.


Along with maximum open area in a well screen, the design must also be<br />

such that the openings do not become clogged by smd particles after the<br />

screen is placed in the aquifer. This is achieved by the use of V-shaped<br />

openings formed by the triangular shaped wire as shown in Fig. 4.2. III Fig.<br />

4.3 is shown a s<strong>and</strong> grain entering <strong>and</strong> passing through a V-shaped opening,<br />

never clogging it, while remaining in other known types of openings to clog<br />

them. This property of the V-shaped opening is of special importance when<br />

developing the well. as the developing process is based on passing the smaller<br />

sizes of s<strong>and</strong> particles through the screen <strong>and</strong> removing them from the well.<br />

This process, a necessary one for the completion<br />

in this chapter.<br />

of the well, is described later<br />

Fig. 4.2 SECTtON OF CONTLNSIOL6-<br />

SLOT TYPE SCREEN SHOW-<br />

ING V-SHAPED OPENINGS.<br />

Another notable feature of the<br />

continuous-slot type of screen is<br />

the fact that the slot openings can<br />

be easily varied in size even bvithin<br />

the same section of screen if the<br />

geologic conditions so require. This<br />

is done simply by altering the set<br />

spacing at which the adjacent wires<br />

are wrapped. Thus a single section<br />

of screen can be made with one or<br />

more different sizes of siot open-<br />

ings. <strong>The</strong> width oi‘ slot openings can<br />

also be held to close tolerances.<br />

Continuous-slot well screens are<br />

made with practically any width of<br />

(opening 0.006 inch <strong>and</strong> larger. <strong>The</strong><br />

slot openings are designated by<br />

II umbers corresponding to the<br />

width of the opening in thou-<br />

s<strong>and</strong>ths of 911 inch. Thus a screen<br />

with a No. IO slot has openings 0.0 IO inch wide.<br />

I,oI~I~= or sl2uttcr-type well screens have rows of openings in the form of<br />

shutter!; (Fig. 4.4). Manut’ucturers can <strong>and</strong> do arrange the optnings either at<br />

right arlgles or parallel to the axis ot’ the scrw1. ‘<strong>The</strong> openings arc produced in<br />

the wal,l of a welded tube by ;I stamping operation using a die. <strong>The</strong> range of<br />

sizes of openings is limited by the sizes of the set of dies used by each<br />

manufacturer. An unlimited range of die sizes would not be practical. This is<br />

one deficiency of this type of screen by comparison with the continuous-slot.<br />

Another important deficiency is the much lower percentage of open area in<br />

shutter-type screens. This is so because sizeable blank spaces must be left<br />

between adjacent openings if the metal is not to be torn In the stamping<br />

process.<br />

Yet another shortcoming of the shutter-type screen is the tendency of the<br />

openings to become blocked during the development of wells (Fig. 4.3) where<br />

the aquifer material contains an appreciable proportion of s<strong>and</strong>. This type of<br />

screen is. therefore, best used in artif‘ic;tlly gravel-packed wells. ;I description<br />

of which is presented later iI1 this &pter.


Fig. 4.3 THE Y-SHAPED OPENINGS<br />

OFTHECONTINUOUSSLOT<br />

TYPE OF SCREEN (RIGHT)<br />

ALLOWS SAN D GRAINS<br />

BARELY SMALLER THAN<br />

THE WIDTH OF THE OPEN-<br />

INGS TO PASS FREELY<br />

WITHOUT CLOGGING.<br />

OPENINGS WITHOUT THE<br />

TAPER TEND TO HOLD<br />

PARTICLES JUST SMALL<br />

ENOUGH TO ENTER THEM.<br />

-<br />

<strong>The</strong> pipe-base well screen is<br />

another type of screen in use. It<br />

consists of a jacket around a perfo-<br />

rated metal pipe. <strong>The</strong> jacket may be<br />

in the form of a trapezoidal-shaped<br />

wire wound directly onto <strong>and</strong><br />

around the pipe (called a wrapped-<br />

on-pipe screen). Alternatively the<br />

wire may be wound over a series of<br />

longitudinal rods spaced at fixed<br />

intervals around the circumference<br />

of the pipe. <strong>The</strong> latter is a more<br />

efficient type of screen as the rods<br />

hold the wire away from the pipe<br />

surface to reduce the blocking of<br />

the screen openings. A stronger<br />

screen can be obtained by using a<br />

slip-on jacket made of an integral<br />

unit of welded well screen.<br />

<strong>The</strong> perforations or holes in the<br />

pipe <strong>and</strong> the spaces between adja-<br />

cent turns of the wrapping wire form two sets of openings in this type of<br />

screen. Usuahy the total open area of the holes in the pipe is less than that<br />

between the wrapping wire. It is, therefore, the holes in the pipe that control<br />

the performance of the screen. Tire percentage open area in the pipe is usually<br />

low <strong>and</strong> hence this type of screen is relatively inefficient.<br />

Very often this type of construction is used in order to avoid making a<br />

screen entirely of the costly noncorrosive alloys such as stainless steel,<br />

bronze or brass. Such alloys are then used only in the jacket while the pipe is<br />

of steel. A screen so constructed with two or more metals would be subject to<br />

failure from galvanic corrosion. Construction of the screen entirely of one of<br />

the noncorrosive alloys, while being more costly, will solve this problem <strong>and</strong><br />

result in a more durable screen.<br />

Drive points or well points, as they are commonly known, are short<br />

lengths of well screen which are attached to successive lengths of pipe <strong>and</strong><br />

driven by repeated blows to the desired position in an aquifer or in a<br />

formation to be dewatered. A forged steel point is usually attached to the<br />

lower end to facilitate penetration into the ground.<br />

<strong>Well</strong> points are made in a variety of types <strong>and</strong> sizes. Most commonly, they<br />

are designed for direct attachment to either l%inch or ‘L-inch pipe. <strong>The</strong>y can<br />

be made of the continuous-slot type of well screen (Fig. 4.9, thus benefitting<br />

from all the desirable features of that type of screen. Such screens will<br />

withst<strong>and</strong> hard driving, but care should be taken to avoid twisting them while<br />

driving.<br />

A common type of well point is the brass jacket type. It consists of a<br />

perforated pipe covered with bronze wire mesh which is, in turn, covered<br />

with a perforated brass sheet to protect it from damage. <strong>The</strong> pointed lower<br />

37


Fig.4.4 LOUVER- OR SHUTTER-<br />

TYPE WELL SCREEN, BEST<br />

USED IN ARTIFIClALLY<br />

GRAVEL-PACKED WELLS.<br />

(From Layne <strong>and</strong> Bowler, inc.,<br />

Memphis, Tennessee.)<br />

end, made of forged steel, carries a<br />

wider shoulder to protect the<br />

screen from damage by gravel or<br />

stones while being driven. <strong>The</strong> lim-<br />

itations of pipe-base screens also<br />

apply to this type of well point.<br />

Another type of well-point con-<br />

struction is the brass tube type<br />

consisting of a slotted brass tube<br />

slipped over perforated pipe. It has<br />

an advantage over the wire-mesh<br />

jacket type in that it is not as easily<br />

ripped or damaged.<br />

<strong>The</strong> sizes of openings for the<br />

continuous-slot type of well points<br />

are designated as described for the<br />

continuous-slot well screens. Mesh-<br />

covered well point openings are<br />

designated by the mesh size in<br />

terms of the number of openings<br />

per linear inch. <strong>The</strong> common sizes<br />

are 40,50,60,70 ;rnd 80 mesh.<br />

Slotted pipe is sometimes used<br />

as a substitute for well screens<br />

particularly in the smaller sized<br />

wells under consideration in this<br />

manual. <strong>The</strong> openings or slots in<br />

the pipe are usually cut with a<br />

sharp saw, electrically operated if<br />

possible, to maintain accuracy <strong>and</strong><br />

regularity in size. Several other<br />

methods have been used, however,<br />

such as cutting with an oxyacetylene torch <strong>and</strong> punching with a chisel <strong>and</strong> die<br />

or casing perforator.<br />

<strong>The</strong> method of construction immediately suggests a number of important<br />

limitations to the use of slotted pipe as well screens. <strong>The</strong>se are: (1) structural<br />

strength requires wide spacing of slots, resulting in a low percentage of open<br />

area; (2) openings may be inaccurate, varying in size throughout the length of<br />

each slot; (3) openings narrow enough to control fine s<strong>and</strong>s are difficult, if<br />

not impossible, to produce; (4) the lack of continuity of the openings reduces<br />

the efficiency of the process of well development; <strong>and</strong> (S) the slotting <strong>and</strong><br />

perforation of steel pipe makes it more readily subject to corrosion, particu-<br />

larly at the jagged edges <strong>and</strong> surfaces.<br />

Slotted plastic pipe has been finding increasing use in small diameter wells<br />

in recent years. Its light weight <strong>and</strong> ease of h<strong>and</strong>ling make it suitable for use<br />

in remote areas not easily reached by motor driven vehicles. It is<br />

noncorrosive <strong>and</strong> less costly than steel pipe in sizes 4 inches in diameter <strong>and</strong><br />

38


Fig. 45 CONTBNUOUSSLOT T Y P E<br />

OF WELL POINT AND EX-<br />

TENSION SECTION.<br />

smaller. In addition, the slots can<br />

be easily made on location with a<br />

sharp saw within reasonable limits<br />

of accuracy. Slots cut spirally<br />

around the circumference of the<br />

pipe in the manner shown in Fig.<br />

4.6 will result in less weakening of<br />

the pipe <strong>and</strong> closer spacing of the<br />

slots than if they were made at<br />

right angles to the axis. Conse-<br />

quently, the percentage of open<br />

area is greater. Slots made at right<br />

angles to the a-xis of plastic pipe are<br />

subject to tearing at both ends if<br />

the slotted pipe is bent when han-<br />

dling it during installation, This<br />

tendency is reduced by the use of<br />

the spiral design.<br />

<strong>The</strong> most convenient type of<br />

joint for use with small diameter<br />

plastic pipe in well construct ion is<br />

the spigotted joint. For these joints,<br />

the manufacturers supply a quick-<br />

setting cement which provides more<br />

than adequate <strong>and</strong> lasting strength.<br />

<strong>The</strong> slotted plastic-pipe screen can<br />

be lowered into a previously drilled<br />

hole on the end of casing of the<br />

same material. Steel clamps are<br />

used to suspend the string of pipes<br />

while adding new lengths. It may<br />

also be washed, open ended, with d jet of water into a previously drilled<br />

hole. Suitable drilling mud should be used during rotary drilling op-<br />

erations to prevent the open hole from collapsing while the string of<br />

plastic pipe is being placed in position. Cart should be taken to wash the<br />

hole clear of all cuttings before placing the pipe. Plastic pipe generally requires<br />

the use of greater care during h<strong>and</strong>ling <strong>and</strong> installation operations than do<br />

metal pipes.<br />

It cannot be contended that slotted plastic pipe will be as efficient a well<br />

screen as the continuous-slot type. However, when only small quantities of<br />

water are required from relatively thick (20 feet <strong>and</strong> greater) s<strong>and</strong> <strong>and</strong> gravel<br />

or gravel aquifers, efficiency loses some of its importance to economy <strong>and</strong><br />

ease of construction. Under these conditions, together with the ones already<br />

mentioned, slotted plastic pipe is an attractive alternative to the continuous-<br />

dot or other manufactured type of well screen. it is particularly suited to the<br />

provision of individual water supplies in remote <strong>and</strong> inaccessible areas.<br />

39


Screen Length, Size of Openings <strong>and</strong><br />

Diameter<br />

<strong>The</strong> length, size of openings <strong>and</strong><br />

diameter of the well screen are the<br />

remaining design features which<br />

influence the efficiency of flow<br />

into a well. Together, they deter-<br />

mine the entrance velocity of flow<br />

through the screen into the well.<br />

This entrance velocity in turn in-<br />

fluences the head or pressure loss<br />

required for maintaining the flow<br />

<strong>and</strong>, as a consequence, also in-<br />

fluences the efficiency of the screen<br />

for that rate of flow.<br />

If designing a well to obtain the<br />

maximum yield from an aquifer,<br />

then the procedure would first be<br />

to select the screen length <strong>and</strong> size<br />

of openings based on the natural<br />

characteristics of the aquifer. <strong>The</strong><br />

screen diameter would then be<br />

selected so as to provide enough<br />

total area of screen openings that<br />

the entrance velocity does not<br />

exceed the chosen design st<strong>and</strong>ard.<br />

Usua!ly, however, small wells are<br />

designed to provide a certain limited<br />

yield, well below the maximum<br />

possible yield, <strong>and</strong> the screen<br />

diameter is first chosen essentially<br />

with a view to keeping costs down<br />

to a minimum. <strong>The</strong> diameter se-<br />

Fig. 4.6 SLOTTED E’LASTIC PIPE. lected would then be the smallest<br />

practicable one, consistent with the<br />

expected yield <strong>and</strong> the diameter of the casing. Normally, it is not considered<br />

good practice to use a well screen of larger diameter than that of the casing.<br />

<strong>The</strong> size of the screen openings is, as before, fixed by the aquifer<br />

characteristics, but the screen length is, in this case, determined by the total<br />

area of screen openings required to keep the entrance velocity at or below the<br />

design st<strong>and</strong>ard. Should the screen length determined on this basis be greater<br />

than the thickness <strong>and</strong> other characteristics of the aquifer would permit, then<br />

the screen length is chosen as the maximum consistent with these limitations.<br />

Following this, a suitable diameter is chosen to be consistent with the design<br />

st<strong>and</strong>ard for entrance velocity into the screen. A more detailed discussion of<br />

the design st<strong>and</strong>ard for the entrance velocity follows discussions of the effects<br />

of aquifer characteristics on the selection of screen length <strong>and</strong> size of<br />

openings.<br />

40


Manufacturers make well screens in two series of sizes, the telescope-size<br />

<strong>and</strong> the pipe-size or ID-size. Telescope-size screens are designed to be<br />

“telescoped” or lowered through the well casing to the final position. <strong>The</strong><br />

diameter of each screen is just sufficiently smaller than the inside diameter of<br />

the corresponding size of st<strong>and</strong>ard pipe to permit the screen to be freely<br />

lowered through the pipe.<br />

<strong>The</strong> pipe-size or ID-size series of well screens have the same inside diameter<br />

as the corresponding size of st<strong>and</strong>ard pipe. This type of screen is used when it<br />

is desired to maintain the same diameter throughout the full depth of the<br />

well. <strong>The</strong>y are provided, in the small sizes under consideration, with either<br />

welded or threaded end connections.<br />

Screen length: <strong>The</strong> screen length selection can be influenced by the thickness<br />

of the aquifer. While definite rules may be set, based on this relationship, for<br />

large wells it would be unwise to do so for small ones. A farmer or home-<br />

owner should not be burdened with a long <strong>and</strong> costly well screen in a thick<br />

aquifer when his requirements are so small as not to warrant it. <strong>The</strong> screen<br />

length should be sufficient to meet his needs with a reasonable drawdown in<br />

the well. As already stated, a compromise must be made between well cost<br />

<strong>and</strong> well efficiency. <strong>The</strong> other ex.treme must also be avoided. Economization<br />

should not be taken to the point where the length of screen provided is such<br />

that the yield barely meets the owner’s present needs. A reasonable allowance<br />

should be made for his future ne:eds. Failure to do so may, in the long run,<br />

prove to be far more costly to the: owner.<br />

It is important to note that in a thick aquifer, well yield is much more<br />

effectively increased by increasing the screen length than by proportionately<br />

increasing the screen diameter. Doubling the screen diameter, for instance,<br />

will only result in an increase of 10 to 15 percent in the yield. In most cases,<br />

however, doubling the screen length will result in the yield being almost<br />

doubled. It is, therefore, much better to use screen length as a controlling<br />

factor on well yield rather than screen diameter in thick aquifers.<br />

<strong>The</strong> role played by aquifer characteristics in screen length selection is best<br />

demonstrated with the use of a few examples. Where a thick layer of coarse<br />

s<strong>and</strong> or gravel underlies a layer of fine s<strong>and</strong> as shown in Fig. 4.714, the screen<br />

length should be at least one-third the thickness of the coarse s<strong>and</strong> layer. For<br />

the sitatuions shown in Fig. 4.7B <strong>and</strong> Fig. 4.7C, almost the entire thickness of .,<br />

the lower layer of coarse s<strong>and</strong> should be screened. Should this prove<br />

inadequate for the desired yield, then it would be necessary to extend the<br />

screen a short distance into the overlying finer s<strong>and</strong>. Where a coarse s<strong>and</strong><br />

overlies a fine s<strong>and</strong> as in Fig. 4.7D, it should normally be sufficient to place<br />

the screen in the coarse s<strong>and</strong> layer with the length being equal to about<br />

one-half the thickness of that layer.<br />

In thin aquifers confined by clays, particularly clays that tend to be easily<br />

eroded when exposed to water, screen lengths should be chosen so as to avoid<br />

the possibility of placing screen openings opposite these clays. Screening of<br />

clay layers could result in their collapse during the well development process<br />

with the well forever producing a muddy water.<br />

41


(A) Coarse port of form&ion is thick (8) Coarse pwt of formotion is thin<br />

(Cl Alternate kyere of coaree <strong>and</strong> fine s4md (0) Coarse material obova fine sond<br />

Fig. 4.7 RECOMMENDED POSITIONING OF WELL SCREENS IN VARIOUS STRA-<br />

TIFIED, WATER-BEARING SAND FORMATIONS.<br />

Screen slot operzirzg: An underst<strong>and</strong>ing of the method of selecting the size of<br />

screen slot openings first of all requires an underst<strong>and</strong>ing of the process <strong>and</strong><br />

objectives of well development. As previously stated, fine material occupies<br />

part of the otherwise larger pore spaces of water-bearing formations, thus in-<br />

creasing the head losses due to friction <strong>and</strong> reducing the quantity of water<br />

yielded per unit of drawdown in a well (specific capacity). <strong>The</strong> object of well<br />

devehpment is to remove as much of this finer material as possible from a zone<br />

around the well to improve the specific capacity <strong>and</strong> efficiency of the well.<br />

<strong>The</strong>re are a variety of methods that are used for inducing the flow of this fine<br />

material through the well screen <strong>and</strong> then extracting it by pumping or bailing.<br />

Some of these methods are described in Chapter 6. It is sufficient to note at<br />

this point that well development involves the removal of the finer aquifer<br />

material in the vicinity of a well <strong>and</strong> that this removal takes place through the<br />

screen <strong>and</strong> out of the casing.<br />

42


<strong>The</strong> limiting size of material to be removed, therelL)re, fixes the size of the<br />

screen slot openings. To determine this limiting size. ;I particlc sir.e ;tnalysis of<br />

the aquifer material must first be undertaken. About 3 cup ut‘ dry, thoroughly<br />

mixed aquifer material is passed through ;I st;indard set of sieves (Fig. 4.X)<br />

<strong>and</strong> the weight of the fractions retained OH each sieve is recorded. <strong>The</strong>se<br />

wei&ts are then expressed as percerltages of the total weight of sample <strong>and</strong> a<br />

SAND AND GRAVEL<br />

---<br />

.\Jl” t 6 mesh)<br />

093” ( Bmesh)<br />

,065” ( IO-mesh)<br />

046” (14 mesh)<br />

,033” I20 mesh)<br />

,023” (28.mesh)<br />

,016” (35 mesh1<br />

,012” (48.mesh1<br />

8ottom oan<br />

--<br />

tl COARSt SAND<br />

,046” f 14 mesh)<br />

033” (20.mesh)<br />

.0X’ (28 mesh)<br />

,016” (35.mesh)<br />

,012” (48.mesh)<br />

.OOB” 165mesh)<br />

Bottom pan<br />

FOR FINE SAND<br />

.023” I 28.mesh)<br />

.016” I 35 mesh)<br />

,012” ( 48 mesh)<br />

.008” ( 65.mesh)<br />

.006” (100.mesh)<br />

Bottom p.m<br />

Fig.43 RECOMMENDED SETS OF<br />

STANDARD SlEVES FOR<br />

ANALYZING SAMPLES OF<br />

WATEK-BEARING SAND OR<br />

GRAVEL.<br />

graph is plot ted of the cumula: ive<br />

percent of tilt‘ sampk retained OII ;I<br />

given sieve <strong>and</strong> all the other sieves<br />

above it versus the size of the given<br />

sieve expressed in th~~us<strong>and</strong>ths of<br />

an inch (Fig. 4.9). A smooth curve<br />

is drawn througil the points on the<br />

graph. This curve shows at a glance<br />

how much of the material is smaller<br />

or larger than 9 given particle size.<br />

For example, the curve in Fig. 4.9<br />

shws tiut 90 percent of the<br />

sample consists of s<strong>and</strong> grains larger<br />

than 0.010 inch or that 10 percent<br />

is smaller than this size. Expressed<br />

in another way, we may say that<br />

the 90 percent size of the s<strong>and</strong> is<br />

0.010 inch.<br />

Before describing the use of’<br />

these sieve-analysis curves for the<br />

selection of screen slot openings it<br />

is desirable to point out another<br />

important use to which they are<br />

put. Reference here is to the use of<br />

the shape <strong>and</strong> location of the curve<br />

to determine the uniformity in size<br />

of the material <strong>and</strong> the ciassifica-<br />

tion of the material in such types as<br />

fine s<strong>and</strong>s, coarse s<strong>and</strong>s <strong>and</strong> gravels.<br />

For example, a narrowly spread,<br />

almost vertical type of curve indi-<br />

cates a uniform type of materia!. If<br />

such a curve occupies the left h<strong>and</strong><br />

corner of the graph sheet (Fig. 4.10A) in the region of the small sieve sizes,<br />

then it represents a fine uniform s<strong>and</strong>. On the other h<strong>and</strong>, a curve widely<br />

spread across the graph sheet, as in Fig. 4.10D, indicates a s<strong>and</strong> <strong>and</strong> gravel<br />

mixture containing very little fine s<strong>and</strong>. An aquifer of such material would<br />

have a higher permeability <strong>and</strong> should be a much better producer of water<br />

than one containing the fine s<strong>and</strong> of Fig. 4.1 OA.<br />

Examinmg Fig. 4.1OD closely shows that removing all the material finer<br />

than the 40 percent size would leave only material coarser than 0.050 inch in<br />

43


100<br />

90<br />

‘p<br />

,ij 80<br />

0<br />

5 70<br />

E 60<br />

& 50<br />

CL<br />

em<br />

=<br />

; 30<br />

E<br />

a 20<br />

IO<br />

0<br />

102030405060708090100<br />

Grain size-in thous<strong>and</strong>ths of an inch<br />

size of Sieve Cumulative Weights CumulotivePer<br />

Opening Retained Cent Retained<br />

0.046” 65 grams I 7%<br />

0.033” IO6 grams 28%<br />

0.023” 179 grams 47%<br />

0.0 16” 266 grams 70%<br />

0.0 12” 3 I2 grams 8 2 %<br />

0.008” 357 grams 94%<br />

Pan 380gran.s 100%<br />

Original weight = 382 grams<br />

Fig. 4.9 TYPICAL SIEVE-ANALYSIS CURVE SHOWS DISTRIBUTION OF GRAIN<br />

SIZES IN PER CENT BY WEIGHT.<br />

the formation. This relatively coarse material would have large pore spaces<br />

through which flow would be relatively free. A well constructed in aquifer<br />

material of this type with a screen carrying 0.050-inch slot openings or a No.<br />

50 slot screen would have a high efficiency after proper development to<br />

remove the fine material.<br />

Generally, well slot openings are designed to retain from 30 to SO percent<br />

of the formation material depending upon the aquifer conditions. <strong>The</strong><br />

selection should tend toward the higher value for fine, uniform s<strong>and</strong>s<br />

containing corrosive waters <strong>and</strong> toward the lower value for coarse s<strong>and</strong> <strong>and</strong><br />

gravel formations. For e;:ample, the 40 percent size is recommended for a<br />

fine, uniform s<strong>and</strong> if the water is noncorrosive. If the water were corrosive,<br />

however, this would cause a gradual enlarging of the slot openings with time<br />

<strong>and</strong> a resulting steady flow of s<strong>and</strong> into the well. <strong>The</strong> designer must be more<br />

conservative under such circumstances <strong>and</strong> select the smaller opening that<br />

would be given by the use of the 50 percent size. In a coarse s<strong>and</strong> <strong>and</strong> gravel<br />

formation, however, the enlarging of the selected slot opening by a few<br />

thous<strong>and</strong>ths of an inch would not create a perpetual s<strong>and</strong>ing problem <strong>and</strong> the<br />

30 percent size may be chosen for the slot opening.<br />

<strong>The</strong> selection of a 30 percent size of opening means that 70 percent of the<br />

formation in the vicinity of the well will be removed in the developing<br />

process. Similarly, 60 percent of the formation is removed with a 40 percent<br />

size of slot opening. Selecting the 30 percent size as against the 50 percent<br />

size means that more material is removed, thus causing the development of a<br />

larger zone in the material surrounding the screen. This usually increases the<br />

specific capacity of the well <strong>and</strong> hence its efficiency in sufficient proportion to<br />

offset the extra cost of development. This is only permissible if the formation<br />

conditions are such as to indicate the use of the larger 30 percent size of slot<br />

opening. A more conservative selection of slot size is recommended whenever<br />

there is doubt about the reliability of the samples provided for analysis.<br />

44


too<br />

90<br />

E 60<br />

z<br />

t 50<br />

:<br />

.L 40<br />

2 30<br />

E<br />

(=j 20<br />

10<br />

0<br />

IO 203040 5060708090100<br />

Groin size, in thousondtns of on inch<br />

A. Fine, uniform s<strong>and</strong> that<br />

yields water at limited<br />

rates.<br />

lO2030405060708090100<br />

Grain size, in thous<strong>and</strong>ths of an inch<br />

C. Fine s<strong>and</strong> with 10 to 20<br />

percent coarse particles<br />

”<br />

10203040506070809010(?<br />

Groin size.in thousondths of on inch<br />

B. Medium <strong>and</strong> coarse s<strong>and</strong><br />

mixture with good per-<br />

meability.<br />

IO 20 30 40 50 60 70 80 90 100<br />

Grain size. in thous<strong>and</strong>ths of on inch<br />

D. S<strong>and</strong> aud gravel mixture<br />

with good permeability.<br />

Fig. 4.10 WICAL SIEVE-ANALYSIS CURVES FOR WATER-BEARING SANDS<br />

AND GRAVELS.<br />

45


Most geologic formations are stratified, having layers of varying particle<br />

size distribution. In such cases, slot size openings should be sejected for<br />

different sections of screen to suit the particle size distribution of the<br />

different strata. TWO more rules should be followed in aquifers where a fine<br />

s<strong>and</strong> overlies coarse material.<br />

1. <strong>The</strong> screen with the slot size designed for the finer material should be<br />

extended at least 2 feet into the coarse material.<br />

2. <strong>The</strong> slot size of the screen designed for the coarse material should never<br />

be greater than twice the slot size for the overlying finer material.<br />

<strong>The</strong>se rules are aimed at reducing the possibility of the well perpetually<br />

producing s<strong>and</strong> from the fine upper layer. Fig. 4.11 illustrates how this<br />

possiiility may arise. It should also be remembered that depths to formation<br />

changes are not always accurately measured <strong>and</strong> it is not always possible to<br />

set screens at the exact levels intended. <strong>The</strong> observation of these rules Thor;<br />

assumes greater importance.<br />

<strong>The</strong> method of selecting screen slot openings so far outlined assumes<br />

Fig. 4.11 SEQUENCE ILLUSTR’iTES POSSIBILITY OF FINE SAND ENTER&NC UP-<br />

PERPARTOF LOWER :‘\ECI’ION OF SCREEN AFTER DEVELOPMENT OF<br />

WELL IF THE LARGLR OPENINGS OF THIS LOWER SECTION OF<br />

SCREEN EXTEND TO THE TOP OF THE COARSE MATERIAL.<br />

conditions that make it practicable to ;Irder well screens after doing sieve<br />

ma?yses of formation materials. In many countries <strong>and</strong> in the remote parts of<br />

~-xx others this procedure would result in costly delays while awaiting an<br />

imported screen. <strong>The</strong> desigxrer oi small wells under such conditions would be<br />

$tnfied jn seheciing a slot opening(s) based upon previous experience with<br />

existing roils in the same aquifer even before drilling operations begin. It<br />

WOU::J ~fi;lso be advisable to select a st<strong>and</strong>yard size of slot opening for a<br />

multipk-well program in the same aquifer in order to benet from the<br />

resultjug xduced costs <strong>and</strong> time saving. This may, however, entail gravel<br />

packing of some of the wells to prevent them from producing fine s<strong>and</strong>. <strong>The</strong><br />

efficiency of other wells may be less than optimum. This, however, is not a<br />

46


prime concern in small we!ls. Generally, the benefits of st<strong>and</strong>ardization of<br />

slot openings of small wells under the above stated conditions would offset<br />

the disadvantages.<br />

<strong>The</strong> entrance velocity is determined by dividing the expected or desired<br />

yield of the well expressed in cubic feet per second by the total area of the<br />

screen openings expressed in square feet.<br />

<strong>The</strong> total area of screen openings is the area of openings provided per foot<br />

of screen multiplied by the selected length of screen expressed in feet. Most<br />

manufacturers provide tables showing the open area per foot of screen for<br />

each size of screen diameter <strong>and</strong> for various widths of slot openings. Table 4.1<br />

is an example of one of these. From this table it is seen that a No. 40 slot,<br />

3-inch diameter telescope-size screen of this type contains 42 square inches of<br />

open area per foot of screen length. A IO-foot length of such a screen would,<br />

therefore, contain 420 square inches of total open area.<br />

<strong>The</strong> design st<strong>and</strong>akd for the entrance velocity is chosen such that the<br />

friction losses in the screen openings will be negligible <strong>and</strong> the rate of<br />

incrustation <strong>and</strong> corrosion will be minimum. Laboratory tests <strong>and</strong> field<br />

TABLE 4.1<br />

INTAKE AREAS FOR SELECTED WIDTHS OF SLOT OPENINGS, (Square Inches per<br />

Lineal Foot of Screen).<br />

Nominal<br />

Screen<br />

Size<br />

2” TS<br />

I $4” PS<br />

2” Ps<br />

3” TS<br />

2w Ps<br />

3” Ps<br />

4” TS<br />

4” PS<br />

Actual Slot No. 10<br />

OD (0.010”)<br />

of Screen (0.25 mm)<br />

l-3/4” 10<br />

2-318” 13<br />

2-5 18” 14<br />

2-314” 15<br />

3-l 18” 17<br />

3-5 18” 20<br />

3-314” 21<br />

4-S IS” 25_<br />

Slot No. 20<br />

(0.020”)<br />

(0.50 mm)<br />

16<br />

22<br />

25<br />

26<br />

30<br />

34<br />

35<br />

44<br />

-<br />

I<br />

Slot No. 40<br />

(0.040”)<br />

(1 .OO mm)<br />

26<br />

36<br />

41<br />

42<br />

48<br />

54<br />

56<br />

68<br />

-<br />

T<br />

-.<br />

Slot No. 60<br />

(0.060”)<br />

(1 SO mm)<br />

32’-. -<br />

45<br />

50<br />

52<br />

59<br />

68<br />

71<br />

I 86<br />

(Courtesy UOP-Johnson Division, Universal<br />

Oil Products Company, St. Paul, Minnesota)<br />

Notes: TS means telescope-size well screen<br />

PS means pipe-size well screen<br />

experience have shown that these objectives are achieved if the screen en-<br />

trance velocity is equal to or less than 0.1 ft per sec. <strong>The</strong> screen length<br />

preferably, or the diameter as is practicable, should be increased if this<br />

velocity is greater than 0.1 ft per sec. On the other h<strong>and</strong>, if the entrance<br />

velocity is appreciably less than 0.1 ft per set - say 0.05 ft per set - the<br />

screen length may be reduced until the entrance velocity more nearly<br />

approaches the st<strong>and</strong>ard of 0.1 ft per sec.<br />

SELECTION OF CASING AND SCREEN MATERIALS<br />

<strong>The</strong> choice of materials that go into the construction of a well is a very<br />

important aspect of water well design. A well constructed of materials with<br />

47


little or no resistance to corrosion can be destroyed beyond usefulness by Y<br />

highly corrosive water within a few months of completion. This will be the<br />

case no matter how cxceknt the other aspects of design. A poor seiec‘tion 1Jf<br />

materials can also result in collapse ot‘ the well due to inadequate strength.<br />

<strong>The</strong> above are factors which hrive considerable intluence urn what is cAled the<br />

useful life of a well. In addition to these influences, the selection of materials<br />

also has considerabie bearing on the cvst of a well. <strong>The</strong> corrusic!n resistant<br />

met& for example. are much mure costly than ordinary steel. <strong>The</strong> choice of<br />

a suitable metal or the provision of a greater thickness of the same metal to<br />

meet strength requirements invuriably results in higher costs. <strong>The</strong>se considera-<br />

tions. therefore. indicate that the designer must exercise great cart’ in the<br />

selection of materials for a well.<br />

<strong>The</strong> designer usually makes his decision on the choice of materials after<br />

considering three main Factors. <strong>The</strong>se are brtater qrtalirrr, strmgth reqrtirements<br />

<strong>and</strong> cyst.<br />

<strong>Water</strong> Quality<br />

<strong>Water</strong> quality. in this context, refers primarily to the mim~ral corltwt of<br />

the water that will be produced by the well. Its effects on metal may be of<br />

two basic types. It may cause wrrc~sim or iwmstatic~t~. Some waters cause<br />

both corrosion tend incrustaticln. Chemical analyses of water samples can<br />

indicate to the skilied interpreter whether a water is likely to be corrosive,<br />

incrusting, or both. Unless knowledge is already available on the nature of the<br />

water in the aquifer, it would be wise to seek the advice of a chemist with<br />

relevant experience before selecting materials for use in a welt.<br />

Grrusic~ is a process which results in the destruction of metals. Corrosive<br />

waters are usually acid <strong>and</strong> mdy contain relatively high concentrations of<br />

dissolved oxygen which is often necessary for <strong>and</strong> increases the rate of<br />

corrosion. Higll concentrations of carbon dioxide, total dissolved solids <strong>and</strong><br />

hydrogen sulfid e with its characteristic odor of rotten eggs are other<br />

indications of a likely corrosive water.<br />

Besides water quality, there are other factors such as velocity offlow <strong>and</strong><br />

dissirr&ritmv oj‘metn[s which contribute to the corrosion process. <strong>The</strong> greater<br />

the velocity of flow, the greater is the removal of the protective corrosion end<br />

products from the surface of’ the metal <strong>and</strong> hericc the cxposurc of that<br />

surf~e to further corrosion. This is another important reason for Xeeping the<br />

velocity through screen openings within acceptable limits. <strong>The</strong> use of two or<br />

more different types of metals such as stainless steel <strong>and</strong> ordinary steel, or<br />

steel <strong>and</strong> brass or bronze should be avoided whenever possible. Corrosion is<br />

usually greatest at the points of contact or closest proximity of the metals.<br />

Corrosion may occur in well screens as welt as casings. It can bc tnore<br />

critical in screens because it can reach damaging proportions much earlier<br />

than in casings. This is because only LI small enlargement of the screen<br />

openings is required for t!ie entry of s<strong>and</strong> through the screen, while the full<br />

thickness of the casing metal must be penetrated for failure of a well through<br />

corrosion of the casing. This is. however, no reason for ignoring the effect 01<br />

corrosion in casings. Casing frtiture by corrosion equally ruins a well as does<br />

failure of the screen. It c;tn cause the intrc~duction of clay <strong>and</strong> potjilted or


otherwise unsatisfactory water into the well. Corrosive well waters have been<br />

observed to destroy steel casings in less than c3 months in Guyana, thus<br />

ruining many wells.<br />

Ordinary stee! <strong>and</strong> iron are not corrosion resistant. <strong>The</strong>re are. however, a<br />

number of metal alloys available with varying degrees of corrosion resistance.<br />

Among these are the stainless steels which combine nickel <strong>and</strong> chromium<br />

with steel <strong>and</strong> also the various copper-based alloys such as brass <strong>and</strong> bronze<br />

which combine traces of silicon, zinc <strong>and</strong> manganese with copper. Manufacturers,<br />

supplied with water analyses, can be expected to provide advice on<br />

the type of metal or metal alloys to be used.<br />

Plastic pipe of the polyvtilyl chloride (pvc) type is an attractive alternative<br />

to the use of metals in small wells, partickllarly under corrosive conditions. It<br />

combines corrosion resistance with adequate strength <strong>and</strong> economy.<br />

Irzcnrsration, unlike corrosion. results not in the destruction of metal, but<br />

in the deposition of minerals on it <strong>and</strong> in the aquifer immediately around a<br />

well. Physical <strong>and</strong> chemical changes in the water in the well <strong>and</strong> the adjacent<br />

formation cause dissolved minerals to change to their insoluble states <strong>and</strong><br />

settle out as deposits. <strong>The</strong>se deposits cause the blocking of screen openings<br />

<strong>and</strong> the formation pore spaces immediately around the screen with a resulting<br />

reduction in the yield of the well.<br />

Incrusting wsters are usually alkaline or the opposite to corrosive waters,<br />

which are acid. Excessive carbonate hardness is a common source of<br />

incrustation in wells. Scale deposits of calcium carbonate (lime scale) occur in<br />

pipes carrying hard waters. Iron <strong>and</strong> manganese, to a lesser extent, are other<br />

common sources of incrustation in wells. Iron causes characteristic reddishbrown<br />

deposits while those of manganese are black.<br />

Often associated with ironcontaining ground waters are iron bacteria.<br />

<strong>The</strong>se minute ‘living organisms are non-injurious to health, but, while aiding<br />

the deposition of iron, produce accumulations of slimy, jelly-like material<br />

which block well screen openings <strong>and</strong> aquifer pore spaces.<br />

Strong solutions of hydrochloric acid are often used in treatment processes<br />

for the removal of all the above-mentioned incrusting deposits. <strong>The</strong> corrosive<br />

effect of this acid treatment, which must be repeated as the need. arises,<br />

makes it necessary to use screens made of corrosion-resistant materials.<br />

Unplasticized polyvinyl chioride pipe would &o withst<strong>and</strong> such treatment .<br />

Further discussion on rehabilitating incrusted wells is presented in Chapter 7.<br />

Strength Requirements<br />

Strength requirements are important in both casing <strong>and</strong> screens but are<br />

generally of mor e concern in screens. Screens must be strong enough to<br />

withst<strong>and</strong> the external radial pressures that could cause their collapse as well<br />

as the vertical loading due to the weight of the casing above them.<br />

Some metals have greater strength characteristics than others. Stainless<br />

steel, for example, can be twice as strong as some copper alloys. Screens <strong>and</strong><br />

casings of adequate strength can be made from any of the metals <strong>and</strong> alloys<br />

commonly used in well construction. Manufacturers usually specify condi-<br />

tions under which their pipes <strong>and</strong> screens can be satisfactorily used. It is often<br />

49


helpful to consult with them on the selection of suitable materials for use in a<br />

well.<br />

cost<br />

Cost considerations may often be the deciding factor in the selection of<br />

construction materials used in small wells. <strong>The</strong> situation may arise, for<br />

instance, where stainless steel would be the most suitable material for use,<br />

combining corrosion resistance with excellent strength <strong>and</strong> a long, useful life.<br />

However, its cost may cause the designer to recommend the use of some<br />

other less suitable material after weighing the benefits *.>f extra useful life<br />

against lower initial cost, the cost of replacement at a later date <strong>and</strong> the<br />

owner’s financial capacity.<br />

h%scelianeous<br />

Other miscellaneous factors also play important roles in the selection of<br />

casing <strong>and</strong> screen materials. Chief among these, with reference to small wells,<br />

would be site accessibility, ease of h<strong>and</strong>ling, availability, <strong>and</strong> on-site<br />

fabrication. !n areas not accessible by motor vehicles <strong>and</strong> necessitating the use<br />

of air transportation, wei$t of materials could be the most decisive<br />

consideration. <strong>The</strong> lighter plastic-type materials would then gain preference<br />

over metals. Ease of h<strong>and</strong>ling, both for transportaiton <strong>and</strong> construction<br />

purposes, would also favor the use of plastic-type material.<br />

<strong>The</strong> above are on!y some of the major considerations in the selection of<br />

materials, Solutions cannot be blindly transferred from one geographic area<br />

to another. Each set of conditions, <strong>and</strong> the advantages <strong>and</strong> disadvantages of<br />

each possible solution, must be carefully considered before making a final<br />

selection.<br />

GRAVEL PACKING AND FORMATION STABILIZATION<br />

Both gravel packing <strong>and</strong> formation stabilization are aids to the process of<br />

well development described earlier in this chapter. A further similarity is the<br />

addition of gravel in the case of gravel packing, <strong>and</strong> coarse s<strong>and</strong> 01 s<strong>and</strong> <strong>and</strong><br />

gravel in the case of fori,tirton stabilization to the annular space between the<br />

screen <strong>and</strong> water-bearing formation. This, however, is where the similarities<br />

end. <strong>The</strong> differences between gravel packing <strong>and</strong> formation stabilization are<br />

indeed very fundamental <strong>and</strong> should be thoroughly grasped.<br />

It will be recalled that the development process in a naturally deveioped<br />

well removes the finer material from the vicinity of the well screen, leaving a<br />

zone of coarser graded material around the well. This cannot be achieved in a<br />

formation consisting of a fine uniform s<strong>and</strong> due to the absence of any coarser<br />

material. <strong>The</strong> object of gravel packing a well is to artificially provide the<br />

graded gravel or coarser s<strong>and</strong> that is missing from the natural formation. A<br />

well treated in this manner is referred to as an artificially gravel-packed well<br />

to distinguish it from the natura!ly developed well.<br />

Drilling by the rotary method through an unconsolidated water-bearing<br />

formation of necessity results in a hole somewhat larger than the outside<br />

diameter of the well screen. This provides the necessary clearance to permit<br />

the lowering of the screen to the bottom of the hole without interference.<br />

50


<strong>The</strong> object of formation stabilization is to fill the annuiar space around the<br />

screen (possibly 2 inches <strong>and</strong> more in width) at least partially, to prevent the<br />

silt <strong>and</strong> clay materials above the aquifer from caving or slumping when the<br />

development work is started. By avoiding such caving, proper development of<br />

the well may be carried out with less time <strong>and</strong> effort. Note that the<br />

development process here is a natural one, with the graded coarse material<br />

coming from the aquifer itself <strong>and</strong> not from the added stabilizing material.<br />

<strong>The</strong> objectives of gravel packing <strong>and</strong> formation stabilization, therefore,<br />

provide the major difference between the two processes. <strong>The</strong>se differences in<br />

objectives also form the basis for the differences in the design features of the<br />

two processes.<br />

Gravel Packing<br />

<strong>The</strong>re are essentially two conditions in unconsolidated formations which<br />

tend to favor artificial gravel-pack construction.<br />

<strong>The</strong> first of these, fine uniform s<strong>and</strong>, has already been mentioned. Such a<br />

s<strong>and</strong> would require a screen with very small slot openings <strong>and</strong>, even so, the<br />

development process would not be satisfactory because of the uniformity of<br />

the s<strong>and</strong> particles. Also, screens with very small slot openings have low<br />

percentages of open area because of the relative thickness of the metal wires<br />

that must be used to provide strength. By artificially gravel packing wells in<br />

such formations, screens with larger slot openings may be used <strong>and</strong> the<br />

improved development results in greater well efficiency. <strong>The</strong> use of artificial<br />

gravel-pack construction is recommended in formations where the screen slot<br />

opening, selected on the basis of.a naturally developed well, is smaller than<br />

0.010 inch (No. 10 slot).<br />

Extensively laminated for&ions provide the second set of conditions for<br />

which gravel pack construction is recommended. This refers to those aquifers<br />

that consist of thin, alternating layers of fine, medium, <strong>and</strong> coarse s<strong>and</strong>. In<br />

such aquifers it is difficult to accurately determine the position <strong>and</strong> thickness<br />

of each individual layer <strong>and</strong> to choose the proper length of each section of a<br />

multiple-slot screen. <strong>The</strong> use of artificial gravel packing in such formations<br />

reduces the chances of error that would result from natural development.<br />

Selection of gravel-pack material: <strong>The</strong> selection of the grading of<br />

gravel-pack material is usually based on the layer of finest material in an<br />

aquifer. <strong>The</strong> gravel-pack material should be such that (1) its 70 percent size is<br />

4 to 6 times the 70 percent size of the material in the finest layer of the<br />

aquifer, <strong>and</strong> (2) its uniformity coefficient is less than 2.5, <strong>and</strong> the smaller the<br />

better. Unifurmi@ coefficient is the number expressing the ratio of the 40<br />

percent size of the material to its 90 percent size. it is well to recall here that<br />

the sizes refer to the percentage retained on a given sieve.<br />

<strong>The</strong> first condition usually ensures that the gravel-pack material will not<br />

restrict the flow from the layers of coarsest material, the permeability of the<br />

pack being several times that of the coarsest stratum. <strong>The</strong> second condition<br />

ensures that the losses of pack material during the development work will be<br />

minimal. To achieve this goal. the screen openings are chosen so as to retain<br />

90 percent or more of the gravel-pack material.<br />

51<br />

.


Gravel-pack material should consist of clean, well rounded, smooth grains.<br />

Quartz <strong>and</strong> other silica-based materials are preferable.<br />

are undesirable in gravel-pack material.<br />

Lirnestorle <strong>and</strong> shale<br />

Tlzickrzess of gravel-pack ewelopes: Gravel-pack envelopes ltre usually 3 to<br />

8 inches thick. This is not out of necessity as tests lime shown that ~1 fraction<br />

of an ~IX!I would satisfactorily retain <strong>and</strong> control the formation s<strong>and</strong>. <strong>The</strong><br />

greater thicknesses are used in order to ensure tllat the well screen is<br />

completely surrounded by the gravel-pack material.<br />

Forzdor. Stabilization<br />

<strong>The</strong> quantity of formation stabilizer should be sufficient to fill the annular<br />

space around the screen <strong>and</strong> casin, u to a level about 30 feet. or as much as is<br />

practicable, above the top of the screen. Ttlis would allow for settlement <strong>and</strong><br />

losses of the materia! +h- ItlIou~ the screen during development. If necessary,<br />

more material should be added as development proceeds to prevent its top<br />

level from falling below that of the screen. <strong>The</strong> settlement of the material is<br />

beneficial in eroding the mud wall formed in boreholes drilled by the rotary<br />

method, thus making well development much easier.<br />

<strong>The</strong> typical concrete or mortar s<strong>and</strong> is widely used as a formation<br />

stabilizer. <strong>The</strong> aquifer conditions under which it IS suitable range from those<br />

requiring a No. 20 (0.020-inch) to those of a No. SO (O.OSO-incll) slot<br />

opening. A specially graded material is not necessary.<br />

SANITARY PROTECTION<br />

It has been stated in Chapter 2 that ground waters are generally of good<br />

sanitary quality <strong>and</strong> safe for drinking. <strong>Well</strong> design should be aimed at the<br />

extraction of this high quality water without contaminating it or making it in<br />

any way unsafe for human consumption. <strong>The</strong> penetration of a water-bearing<br />

formation by a well provides two main routes for possible contamination of<br />

the ground water. <strong>The</strong>se are the open. top end of the casing <strong>and</strong> the annular<br />

space between the casing <strong>and</strong> the borellole. <strong>The</strong> designer must concern<br />

himself with the prevention of contamination througli tliese two routes.<br />

Upper Terminal<br />

<strong>Well</strong> casing should extend at least I foot above the general level of the<br />

surrounding l<strong>and</strong> surface. It sflould be surrounded at the ground surt’ace by a<br />

4-inch thick concrete slab extending at least 2 feet in all directions. <strong>The</strong> upper<br />

surface of this slab <strong>and</strong> its immediate surroundings should be gently sloping<br />

so as to drain water away from the well. as shown in Fig. 4.12. It is also good<br />

practice to place a drain around the outer edge of the sldb <strong>and</strong> extend it to a<br />

discharge point at some distance from the well. A sanitary well seal should be<br />

provided at the top of the well to prevent the entrance of contaminated<br />

water or other objectionable material directly into the well. Examples of<br />

these are shown in Fig. 4.13.<br />

Lower Terminal of the Casing<br />

For artesian aquifers. the water-tight casing should be extended down-<br />

wards into tlie impermeable formation (sucl1 ;f~ a clay) which caps the


Pump unit<br />

Sanitary well seal<br />

I<br />

/<br />

,Relnfarced concrete<br />

‘Cover slab sloped away from pump<br />

-%<br />

--- -<br />

--<br />

-<br />

. -<br />

-1<br />

-<br />

--<br />

-<br />

--,r<br />

L-I:<br />

- ----<br />

-L-F<br />

I<br />

-<br />

-_<br />

--<br />

-<br />

---<br />

Fig. 4.12 S:\NlThKY PKO’I‘ti”fION OF l’PPt;.K ‘i‘ER31IN~\tL. Ok WCI.1..<br />

Drop pope Soft rubber ex-<br />

p<strong>and</strong>lng gasket<br />

<strong>Well</strong> casing<br />

k.A<br />

\<br />

I OroDtme -7 Soft rubber ex-<br />

p<strong>and</strong>ing gasket<br />

<strong>Well</strong> casing<br />

\


In water-table aquifers the casing should be extended at least 5 feet below<br />

the lowest expected pumping level. This limiting distance should be increased<br />

to 10 feet where the pumping level is less than 25 feet from the surface.<br />

<strong>The</strong> above are general rules which should be applied with some flexibility<br />

where geologic conditions so require.<br />

Grouting <strong>and</strong> Sealiug Casii<br />

<strong>The</strong> drilled hole must of necessity be larger than the pipe used for the well<br />

casing. This results in the creation of an &regularly shaped annular space<br />

around the casing after it has been placed in position. It is important to fill<br />

this space in order to prevent the seepage of contaminated surface water<br />

down along the outside of the casing into the well <strong>and</strong> also to seal out water<br />

of unsuitable quality in strata above the desirable water-bearing formation.<br />

In caving material, such as s<strong>and</strong> or s<strong>and</strong> <strong>and</strong> gravel, the annular space is<br />

soon filled as a result of caving. In such cases, therefore, no special<br />

arrangements need be made for filling the annular space. However, where the<br />

material overlying the water-bearing formation is of the non-caving type, such<br />

as clay or shale, then the annular space should be grouted with a cement or<br />

clay slurry to a minimum depth of 10 feet below the sirface. Where the<br />

thickness of the clayey materials permit it, increasing the depth of grout to<br />

about 15 feet would provide added safety. <strong>The</strong> diameter of the drilled hole<br />

should be 3 to 6 inches larger than the permanent well casing to facilitate the<br />

placing of the grout. It is important to remove temporary casing when<br />

grouting rather than simply filing the space between the two casings as<br />

vertical seepage can readily occur down the outside of any unsealed casing.<br />

Methods of mixing <strong>and</strong> placing the grout are discussed in Chapter 5.<br />

54


<strong>The</strong>re are four basic operations involved in the construction of tubular<br />

wells. <strong>The</strong>se are the drilling operation, casing instailation, grouting of the<br />

casing when necessary <strong>and</strong> screen installation.<br />

WELL DRILLING METHODS<br />

<strong>The</strong> term well drilling methods is being used here to include ail methods<br />

used in creating holes in the ground for well construction purposes. As such,<br />

it includes methods such as boring <strong>and</strong> driving which are not drilling methods<br />

in a pure sense. <strong>The</strong> classification is one of convenience in the absence of a<br />

better descriptive term. <strong>The</strong> limitations on well diameter (4 inches <strong>and</strong> less)<br />

exclude the dug well from consideration. <strong>The</strong> sections that follow describe<br />

the bored <strong>and</strong> driven, the percussion, hydraulic rotary <strong>and</strong> jet drilled wells.<br />

Boring<br />

Boring of small diameter wells is commonly undertaken with h<strong>and</strong>-turned<br />

earth augers, though power-operated augers are sometimes used. Two com-<br />

mon types of h<strong>and</strong> augers are shown in Fig. 5.1. <strong>The</strong>y each consist of a shaft<br />

Fig. 5.1 HAND AUGLRS. (From Fig. 6, <strong>Well</strong>o. Department of the Army Technical<br />

<strong>Manual</strong> TM5297, 1957.)<br />

with wooden h<strong>and</strong>le at the top <strong>and</strong> a bit with curved blades at the bottom.<br />

<strong>The</strong> blades are usually of the fixed type, but augers with blades that are<br />

adaptabie to different diameters are also available. Shafts are usually made up<br />

of S-ft sections with easy latching couplings.<br />

<strong>The</strong> hole is started by forcing the blades of the bit into the soil with a<br />

turning motion. Turning is continued until the auger bit is full of material.<br />

<strong>The</strong> auger is then lifted from the hole, emptied <strong>and</strong> returned to use. Shaft<br />

s5


extensions are added as needed to bore to the desired depth. <strong>Well</strong>s shallower<br />

than 15 ft ordinarily require no other equipment than the auger. Deeper<br />

wells. however. require the use of a light tripod with a pulley at the top, or a<br />

raised platform, so that the auger shaft can be inserted <strong>and</strong> removed from the<br />

hole without disconnecting all shaft sections.<br />

<strong>The</strong> spiral auger shown in Fig. 5.2 is used in place of the normal cutting bit<br />

to remove stones or boulders en-<br />

countered during boring operations.<br />

When turned in a clockwise direc-<br />

tion, the spiral twists around a<br />

stone so that it can be lifted to the<br />

surface.<br />

<strong>The</strong> method is used in boring to<br />

depths of about 50 ft in clay, sift<br />

<strong>and</strong> s<strong>and</strong> formations not subject to<br />

caving. Boring in caving formations<br />

may be done by lowering casing to<br />

the bottom of the hole <strong>and</strong> boring<br />

ahead little by little while forcing<br />

the casing down.<br />

Fig. 5.2 SPIRAL AUGER.<br />

Driving<br />

Driven wells are constructed by<br />

driving into the ground a well point<br />

fitted to the lower end of tightly<br />

connected sections of pipe. <strong>The</strong><br />

well point must be sunk to some<br />

depth within the aquifer <strong>and</strong> below<br />

the water table. <strong>The</strong> riser pipe<br />

above the well point functions as<br />

the well casing.<br />

Equipment used includes a drive<br />

hammer, drive cap to protect the<br />

top end of the riser pipe during<br />

driving, tripod, pulley <strong>and</strong> strong<br />

rope with or without a winch. A<br />

light drilling rig may be used instead<br />

of the tripod assembly. <strong>Well</strong><br />

points can be driven either by h<strong>and</strong><br />

methods or with the aid of machines. Fig. 5.3 shows the assembly for a<br />

purely h<strong>and</strong>-driven method. <strong>The</strong> drive-block assemblies commonly operated<br />

by a drilling rig or by h<strong>and</strong> with the aid of a tripod <strong>and</strong> tackle are shown in<br />

Fig. 5.4.<br />

Whatever the method of drivin g, a starting hole is first made by boring or<br />

digging to a depth of about Z feet or more. As driving is generally easier in a<br />

saturated formation, the starting hole should be made deep enough to<br />

penetrate the water table if the latter is sufficiently shallow. <strong>The</strong> starting hoie<br />

should be vertical <strong>and</strong> slightly larger in diameter than the well point. <strong>The</strong> well<br />

56


Ham? driver ----k-<br />

Htle backfilled<br />

with pudd.ed clay<br />

- Drive cap<br />

Fig. 5.3 SlMPLE TOOL FOR DRIV-<br />

ING WELL POINTS TO<br />

DEPTHS OF 15 TO 30 FT.<br />

point is inserted into this hole dnd<br />

driven to the desired depth, S-ft<br />

lengths of riser pipe being added as<br />

necessary. Pipe couplings should<br />

have recessed ends <strong>and</strong> tapered<br />

threads to provide stronger connec-<br />

tions than ordinary plumbing<br />

couplings. <strong>The</strong> pipe <strong>and</strong> coupling<br />

threads should be coated with pipe<br />

thread compound to provide air-<br />

tight joints. <strong>The</strong> well-point assem-<br />

bly should be guided as vertically as<br />

possible <strong>and</strong> the driving tool, when<br />

suspended, should be hung directly<br />

over the center of the well. <strong>The</strong><br />

weight of the driving tool may<br />

range from 75 to 300 pounds.<br />

Heavier tools require the use of a<br />

power hoist or light drilling rig. <strong>The</strong><br />

spudding action of a cable-tool<br />

drilling machine (Fig. 5.14) is well<br />

suited for rapid well point driving.<br />

Slack joints should be periodically<br />

tightened by turning the pipe light-<br />

iy with a wrench. Violent twisting<br />

oi‘ the pipe mikes driving no easier<br />

<strong>and</strong> can result in damage to the well<br />

point. Thus must, therefore, be<br />

avoided.<br />

Dr%en wells can be installed<br />

only ln unconsolidated formations<br />

relatively free of cobbles <strong>and</strong><br />

boulders. H<strong>and</strong> driving can be<br />

undertaken to depths up to about<br />

30 feet; machine driving can<br />

achieve depths of 50 feet <strong>and</strong><br />

greater.<br />

Jetting<br />

<strong>The</strong> jetting method of well drilling uses the force of a high velocity stream<br />

or jet of fluid to cui a hole into the grourrd. <strong>The</strong> jet of fluid loosens the<br />

subsurface materials <strong>and</strong> transports them upward <strong>and</strong> out of the hole. <strong>The</strong><br />

rate of cutting can be improved with the use of a drill Si.t (Fig. 5.5) which can<br />

be rotated as well as moved in an up-<strong>and</strong>down chopping manner.<br />

<strong>The</strong> fhrid circulation system is similar to that of conventional rotary drilling<br />

described later in this chapter. indeed the equipment can be identical with<br />

that used for rotary drilling, with the exception of the drill bit. Simple<br />

equipment for jet drilling is shown in Fig. 5%. A, tripod made of ‘I-inch<br />

57


Fig. 5.4 DRIVE-BLOCK ASSEMBLIES<br />

FOR DRIVING WELL<br />

POINTS.<br />

Fig.55 BITS FOR JET DRILLING.<br />

(From Fig. 17, We&s, Depart-<br />

ment of the Army Technical<br />

<strong>Manual</strong> TMS-297, 1957.)<br />

58<br />

galvanized iron pipe is used to<br />

suspend the galvanized iron drill<br />

pipe <strong>and</strong> the bit by means of a U-<br />

hook (at the apex of the tripod),<br />

single-pulley block <strong>and</strong> manila rope.<br />

A pump having a capacity of ap-<br />

proximately 150 gallons per minute<br />

at a pressure of 50 to 70 pounds<br />

per square inch is used to Li-;:e the<br />

drilling tluid through suitable hose<br />

<strong>and</strong> ;1 small swivel on through the<br />

drill pipe <strong>and</strong> bit. <strong>The</strong> fluid, on<br />

emsrging from the drilled hole,<br />

tra:iels in a narrow ditch to a settling<br />

pit where the drilled materials (cut-<br />

tings) settle out <strong>and</strong> then to a stor-<br />

age pit where it is again picked up<br />

by the pump <strong>and</strong> recirculated. <strong>The</strong><br />

important features of settling <strong>and</strong><br />

storage pits are described in the<br />

later section of this chapter dealing<br />

with hydraulic rotary drilling. A<br />

piston-type reciprocating pump<br />

would be preferred to a centrifugal<br />

one because of the greater mainte-<br />

nance required by the latter as a<br />

result of! leaking seals <strong>and</strong> worn<br />

impellers <strong>and</strong> other moving parts.<br />

<strong>The</strong> ::pudding percussion act ion<br />

can be imparted to the bit either by<br />

means of a hoist or by workmen<br />

alternately pulling <strong>and</strong> quickly re-<br />

leasing the free end of the manila<br />

rope on the other side of the block<br />

from’ the swivel. This may be done<br />

while other workmen rotate the<br />

drib pipe. <strong>The</strong> drilling fluid may be<br />

<strong>and</strong> is very often plain water.<br />

Depths of the order of 50 feet may<br />

be achieved in some formations<br />

using water as drilling ff uid without<br />

undue caving. When caving d3es<br />

occur, then a drilling mud as<br />

described in the later section on<br />

hydraulic rotary drilling should be<br />

used.<br />

<strong>The</strong> jetting method is particular-


single wlley block<br />

: /Tripod<br />

Fig. 5.6 SIMPLE EQUIPMENT FOR JET OR ROTARY DRILLING.<br />

ly successful in s<strong>and</strong>y formations. Under these conditions a high rate of<br />

penetration is achieved. Hard clays <strong>and</strong> boulders dv present problems.<br />

Hydraulic Percussion<br />

<strong>The</strong> hydraulic percussion method uses a similar string of drill pipe to that<br />

of the jelting method; <strong>The</strong> bit is also similar except for the ball check valve<br />

placed between the bit <strong>and</strong> the lower end of the drill pipe. <strong>Water</strong> is intro-<br />

duced continuously into the borehole outside of the drill pipe. A recipro-<br />

cating, up-<strong>and</strong>-clown motion applied to the drill pipe forces water with<br />

suspended cuttings through the check vaPvc <strong>and</strong> into the drill pipe on the<br />

down stroke. trapping it a~ the valve closes on the up stroke. Continuous<br />

reciprocating motion produces a pumping action, lifting the fluid <strong>and</strong> cuttings<br />

to the top of the drill pipe where they are discharged into a settling tank. <strong>The</strong><br />

cycle of circulation is then complete. Casing is usually driven as drilling<br />

proceeds.<br />

<strong>The</strong> method uses a minimum of equipment <strong>and</strong> provides accurstc samples<br />

of formations penetrated. It is well suited for use in clay <strong>and</strong> s<strong>and</strong> forma-<br />

tions that are relatively free of ccbbles or boulders.<br />

Sludger<br />

<strong>The</strong> sludger method is the name given to a forerunner of the hydraulic<br />

percussion method described in the previous section. It is accomplished en-<br />

tirely with h<strong>and</strong> tools. makes use of locally available materials. such as


amboo for scaffoiding, <strong>and</strong> is particularly suited to use in inaccessible areas<br />

where labor is plentiful <strong>and</strong> cheap. <strong>The</strong> first description of the method is<br />

believed to have come from East Pakistan where it has been used extensively.<br />

In the sludger method, as used in East Pakistan. scaffolding is erected as<br />

shown in Fig. 5.7. <strong>The</strong> reciprocating, up-<strong>and</strong>down motion of the driil pipe is<br />

provided by means of the manually<br />

operated bamboo lever to which the<br />

drill pipe is fastened with a chain. A<br />

sharpened coupling is used as a bit<br />

at the lower end of the drill pipe.<br />

<strong>The</strong> man shown seated on the scaffolding<br />

uses his h<strong>and</strong> to perfortn<br />

the functions of the check valve as<br />

used in the hydraulic percussion<br />

method, though. in this .case at the<br />

top instead of the bottom of t!le<br />

drill pipe. A pit, approximately 3<br />

Fig. 5.7 BAMBOO SCAFFOLDING,<br />

PIVOT AND LEVER USED<br />

IN DRILLING BY THE SLUD-<br />

GER METHOD. (From “Jctting<br />

S m a I 1 Tubewells By<br />

H<strong>and</strong>.” Wafer Supple <strong>and</strong> Sanitaiion<br />

in Develop& Counfeet<br />

square <strong>and</strong> 2 feet deep, around<br />

the drill pipe, is filled with water<br />

which enters the borehole as drilling<br />

progresses. On the upstroke of<br />

the drill pipe its top end is covered<br />

by the h<strong>and</strong>. <strong>The</strong>. h<strong>and</strong> is removed<br />

on the downstroke (Fig. C.8), thus<br />

allowing some of the fluid <strong>and</strong> cuttings<br />

sucked into the bottom of the<br />

drill pipe to rise <strong>and</strong> overflow. Continuous<br />

repetition of the process<br />

fries. AID-LiNC/IPSED Item<br />

causes the penetration of the drill<br />

No. IS. June 1967.) pipe into the formation <strong>and</strong> creates<br />

a similar pumping action to that of<br />

the hydraulic percussion method. New iengths of drill pipe are added as<br />

necessary. <strong>The</strong> workman whose h<strong>and</strong> operates as the flap valve changes posi-<br />

tion up md down the scaffolding in accordance with the position of the top<br />

of the drill pipe. <strong>Water</strong> is added to the pit around the drill pipe as the level<br />

drops. When the hole has been drilled to the desired depth, the drill pipe is<br />

extracted in sections;care being taken to prevent caving of the borehole. <strong>The</strong><br />

screen <strong>and</strong> casing are then lowered into position.<br />

<strong>Well</strong>s up to250 feet deep have been drilled by this method in fine or s<strong>and</strong>y<br />

formations. Reasonably accurate formation samples can be obtained during<br />

drilling. Costs are confined to labor <strong>and</strong> the cost of pipe, <strong>and</strong> can therefore,<br />

be very low. <strong>The</strong> method requires no great operating skills.<br />

Hydraulic Rotary<br />

Hydraulic rotary drilling combines the use of a rotating bit for cutting the<br />

borehole with that of continuously circulated drilling fluid for removal of the<br />

cuttings. <strong>The</strong> basic parts of a conventional rotary drilling machine or rig are a<br />

derrick or mast <strong>and</strong> hoist: a power operllted revolving table rhat rotates the


Fig,..8 MAN ON SCAFFOLDING<br />

RAISES HAND OFF PIPE<br />

ALLOWING DRILL FLUID<br />

AND CUTTINGS TO ESCAPE.<br />

(From “Jetting Small Tube-<br />

weiis By H<strong>and</strong>,” <strong>Water</strong> Supply<br />

<strong>and</strong> <strong>Sanitation</strong> in Developing<br />

Countries, AID-UNC/IPSED<br />

Item No. 15, June, 1957.)<br />

drill stem <strong>and</strong> drill bit below it; a<br />

pump for forcing drilling fluid via a<br />

length of hose <strong>and</strong> a swivel on<br />

through the drill stem <strong>and</strong> bit: <strong>and</strong><br />

a power unit or engine. <strong>The</strong> drill<br />

stem is in effect a long tubular shaft<br />

consisting of three parts: the kelly;<br />

as many lengths of drill pipe as re-<br />

quired by the drilling depth; <strong>and</strong><br />

one or more lengths of drill collar.<br />

<strong>The</strong> kelly or the uppermost sec-<br />

tion of the drill stem is made a few<br />

feet longer <strong>and</strong> of greater wall<br />

thickness than a length of drill pipe.<br />

Its outer shape is usually square<br />

(sometimes six-sided or round with<br />

lengthwise grooves), fitting into a<br />

similarly shaped opening in the<br />

rotary table such that the kelly can<br />

be freely moved up or down in the<br />

opening even while being rotated.<br />

At the top end of the kelly is the swivel which is suspended from the hook of<br />

a traveling hoist block.<br />

Below the kelly are the drill pipes, usually in joints about 20 feet long.<br />

Extra heavy lengths of drill pipe called drill collars are connected immediately<br />

above the bit. <strong>The</strong>se add weight to the lower end of the drill stem <strong>and</strong> so help<br />

the bit to cut a straight, vertical hole.<br />

<strong>The</strong> bits best suited to use in unconsolidated clay <strong>and</strong> s<strong>and</strong> formations are<br />

drag bits of either the fishtail or three-way design (Fig. 5.9). Drag bits have<br />

short blades forged to thin cutting edges <strong>and</strong> faced with hard-surfacing metal.<br />

<strong>The</strong> body of the bit is hollow <strong>and</strong> carries outlet holes or nozzles which direct<br />

the fluid flow toward the center of each cutting edge. This flow cleans <strong>and</strong><br />

cools the blades as drilling progresses. <strong>The</strong> three-way bit performs smoother<br />

<strong>and</strong> faster than the fishtail bit in irregular <strong>and</strong> semi-consolidated formations<br />

<strong>and</strong> has less tendency to be deflected. It cuts a little slower than the fishtail<br />

bit, however, in truly unconsolidated clay <strong>and</strong> s<strong>and</strong> formations.<br />

Coarse gravel formations <strong>and</strong> those containing boulders may require the<br />

use of roller-type bits shown in Fig. 5.10. <strong>The</strong>se bits exert a crushing <strong>and</strong><br />

chipping action as they are rotated, thus cutting harder formations effective-<br />

ly. Each roller is provided with a nozzle serving the same purpose with respect<br />

to the rollers as those on the drag bits with respect to their blades.<br />

<strong>The</strong> pump forces the drilling fluid through the hose, swivel, rotating drill<br />

stem <strong>and</strong> bit into the drilled hole. <strong>The</strong> drill fluid, as it flows up <strong>and</strong> out of the<br />

drilled hole, lifts the cuttings to the ground surface. At the surface the fluid<br />

flows in a suitable ditch to a settling pit where the cuttings settle out. From<br />

here it overflows to a storage pit where it is again picked up by the pump <strong>and</strong><br />

recirculated. <strong>The</strong> settling pit should be of volume equal to at least three times<br />

61


Three-way Fishtail<br />

Fig. 5.9 ROTARY DRILL BITS. (From<br />

Fig. 41, <strong>Well</strong>s. Department of<br />

the Army Technical <strong>Manual</strong><br />

TMS-297, 1957.)<br />

Fig. 5.10 ROLLER-TYPE ROTARY<br />

DRILL BIT.(From Reed Drill-<br />

ing Tools. Houston, Texas.)<br />

the volume of the hole being<br />

drilled. 1 t should be relatively shai-<br />

low (a depth of 2 feet to 3 feet<br />

usually proving satisfactory) <strong>and</strong><br />

About twice as long in the direction<br />

of flow 3s it is wide <strong>and</strong> deep. In<br />

accordance with fhe above rules a<br />

settling pit 6 feet long, 3 feet wide<br />

<strong>and</strong> 3 feet deep would be suitable<br />

for the drilling of 4-inch wells (hole<br />

diameter of’ 6 inches) 100 feet in<br />

depih, A system of baffles may also<br />

be used to provide extra travel time<br />

in the pit <strong>and</strong> ih:ls improve the<br />

settling.<br />

<strong>The</strong> storage pit is inteilded<br />

mainly to provide enough vo!ume<br />

from which to pump. A pit 3 feet<br />

square <strong>and</strong> 3 feet deep would be<br />

satisfactory. It may either be com-<br />

bined with the settling pit to form a<br />

single, larger pit or separated from<br />

the settling pit by a connecti!lg<br />

ditch. Drill hole cuttings should be<br />

periodically removed from the pits<br />

<strong>and</strong> ditches as is necessary.<br />

<strong>The</strong> drilling fluid performs other<br />

important functions in the drilled<br />

hole besides those already men-<br />

tioned. <strong>The</strong>se are discussed later in<br />

this chapter.<br />

Fig. 5.1 I shows a number of the<br />

component parts of a rotary drilling<br />

rig. <strong>The</strong> ch,ain pulldowns shown are<br />

used mainly for applying greater<br />

do\,lnward force to the drill pipe<br />

<strong>and</strong> bit but are not normally re-<br />

quired for the drilling of small wells<br />

in unconsolidated format ions.<br />

Rotary drilling equipment for<br />

small diameter shallow wells can be<br />

much simpler <strong>and</strong> less sophisticated than that just described. <strong>The</strong> truck,<br />

.<br />

trailer or skid mounted derrick or mast can be substituted by a tripod made<br />

of Z-inch or 3-inch galvanized iron pipe. A small suitable swivel can be suspended<br />

by rope through a single-pulley block from a (J-hook fLved by a pin at<br />

the apex of the tripod. Drill pipe <strong>and</strong> bits both made from galvanized iron


Cutting edges<br />

Galvanized iron pipe<br />

Outlet for direct-<br />

ing drill fluid onto<br />

cutlmg edge<br />

collapse. In addition, tjle drilling<br />

mud forms ;I mud cake or rubbery<br />

sort of lining on the wail of the<br />

borehoic. This mud aice holds the<br />

loose part icies of the forma tioti in<br />

place, protects the wail from being<br />

eroded by the upward strem uf<br />

fluid <strong>and</strong> scais the wall tu prevent<br />

ic~ss c)f fluid into permeable forma-<br />

tions such ;1s s<strong>and</strong>s <strong>and</strong> gravels.<br />

Drillers must be careful mt to in-<br />

crease the pumpirig rate to the<br />

puint where it c;lcszs destruction ot<br />

the mud czke <strong>and</strong> cming of the<br />

hole.<br />

<strong>The</strong> drilling rluid must aisv be<br />

such that the clay doesn’t sett!e c~ut<br />

of t he mixture when pumping<br />

ce;mx but rcmins somewhat eias-<br />

tic, thus keeping the Cuttings in sus-<br />

pensm. Ail rlaturul clays do nut<br />

exhibit this property. k ncwtl ;is<br />

gdirr:. Beiitonitc clays do cxiiihit<br />

satisfuctory gel strength <strong>and</strong> tire<br />

added to uaturltl clays to improve<br />

their gel properties to desired Icvcis.<br />

<strong>The</strong> driller must 111so use his<br />

good judgernerlt iu arrivilig tit ;i suit-<br />

ubie tluid thickness. TW thin ;I<br />

tluid rc-suits in caving 01 tile hole<br />

und loss of tluid into permeable i‘or-<br />

maths. 011 tilt‘ other h<strong>and</strong>. tluid<br />

slmuid bc no rilickcr rhn is IICWS-<br />

sary to nlairltrtin 3 .


-.<br />

- -<br />

-^ - - z-


inexperienced driller because of the differential rate of tr;insport 01‘ tht~ cuttings<br />

out of the borehole. <strong>The</strong> need for proper drilling mud c‘or\trcA ~1s~~<br />

requires considertlbie experience on the part of the rotary driilcr. Ti~c training<br />

of rotary drillers can be more time consuming und dit‘tkult. lkspitc ~hcsc‘<br />

disadvantages the method finds considtx~bic appiic;lt iorl in the coust ruct ioll<br />

of wells in al! types of formations<br />

t ions.<br />

Cable-Tool Percussion<br />

tend p;lrticuiarly url~ollsolidvttd t‘orma-<br />

Cable-tool percussion is one of the oldest methods used il: well construetion.<br />

It employs the pfincipie of 3 frtx-fulii:lg heavy bit delivering blows<br />

against the bottom of ri hole auci thus penetrating inttj the ground. C’uttings<br />

are periodically rerncved by rt bailer or s:md punlp. ‘I‘ool~ ti)r drillin:: aid<br />

bairing tire carried on separate fines or cttblcs spuoied cjn independent hoisting<br />

drums.<br />

<strong>The</strong> basic components of ;t cable-tool drilling rig are ;1 power unit for<br />

driving the bull reel (carrying the drilling csbie) <strong>and</strong> the s<strong>and</strong> reel (carrying<br />

the bailing cable). 2nd ;I spudding btxm tar impart in, (1 the drilling motiuu tu<br />

the drill tools. alf mounted on ;I t‘r;mx which carries ;I derrick or mat ut<br />

suitable height for the USC of ;I striug of drilling<br />

cable-tool drilling rig on ioctttiun.<br />

tools. Fig. 5.14 shahs ;I<br />

Fig. 5.14 STAR 7 1 CABLE-TOOL DRILLING RIG.


- Drill line<br />

.Rope et hzket<br />

Drilling jars<br />

- Drill s item<br />

-Drill bit<br />

Fig. 5.15 COMPONENTS OF A STRING<br />

OF DRILL TOOLS FOR<br />

CABLE-TOOL PERCUSSION<br />

METHOD. (-From Ac‘mt‘ Fib<br />

ing Tool Cornpan)-. Parkrr~<br />

burg. We\t Virginia.)<br />

Four items comprise ;1 full string<br />

of drilling tools. <strong>The</strong>se are the drill<br />

bit. drill stem. drilling jars <strong>and</strong> rope<br />

socket (Fig. 5.15 ). <strong>The</strong> chisel-shaped<br />

drill bit is used to loosen unconsolidated<br />

rock materials <strong>and</strong> with its<br />

reciprocating action mis these materials<br />

into a slurry which is later removed<br />

by baiimg. When drilling in<br />

dry formations water must be added<br />

to the hole to form the slurry. <strong>The</strong><br />

water course on the bit permits the<br />

movement of the slurry relative to<br />

the bit <strong>and</strong>. therefore, aids in the<br />

free-failing reciprocating motion of<br />

the bit. <strong>The</strong> drill stem immediately<br />

above the bit merely gives additional<br />

weight to the bit <strong>and</strong> added length<br />

0 the ;tring of tools to help mainain<br />

a straight hole.<br />

<strong>The</strong> jars consist of a pair ot<br />

1 inked steel bars which can be moved<br />

il n avertical direction relative to each<br />

other. <strong>The</strong> gap or stroke of the drilling<br />

jars is 6 to 0 inches. Jars are used<br />

to provide upward blows when necessary<br />

to free a string of tools stuck<br />

or wedged in the drill hole. Drilling<br />

jars are to be differentiated t’rom<br />

similarly constructed fishing jars<br />

which have ;1 stroke of 18 to 36<br />

inches <strong>and</strong> art‘ used in fishing or recovering<br />

tools which have come<br />

loose from the string of drilling<br />

tools in Ihe hole.<br />

<strong>The</strong> rope socket connects the<br />

string of tools to the cable. its con-<br />

struction is such as to provide a<br />

slight clockwise rotation of the<br />

drilling tools relative to the cable.<br />

This rotation of the tools ensures<br />

the drilling of ;1 round hole. Another<br />

function of the rope socket is to<br />

provide. by its weight. part of the<br />

energy of the upward blows of the<br />

jars.<br />

<strong>The</strong> components of the tool


string are usually joined together by tool joints of the box <strong>and</strong> pin type with<br />

st<strong>and</strong>ard American Petroleum institute (API) designs <strong>and</strong> dimensions.<br />

<strong>The</strong> bailer is simply a length elf pipe with ;I check valve at the bottom. <strong>The</strong><br />

v&e may be either the tlat-pattern or bell-<strong>and</strong>-tongue type called the dart<br />

valve. Fig. 5.16 shows a dart valve bailer being discharged by resting the<br />

tongue of the valve on a timber block.<br />

<strong>The</strong> s<strong>and</strong> pump (Fig. 5.17) is a<br />

bailer fitted with a plunger whicfl,<br />

when puiled upwards, creates a vac-<br />

uum that opens the check valve <strong>and</strong><br />

sucks the slurried cuttings into the<br />

bailer. S<strong>and</strong> pumps are always made<br />

with flat-pattern check valves.<br />

it is important that the drilling<br />

motion be kept in step with tile fail<br />

of the string of tools for good opera-<br />

tion. <strong>The</strong> driller must see to it that<br />

the engine speed has the same tim-<br />

ing as the I’41 of the tools <strong>and</strong> the<br />

stretch of the cable. This is a skill<br />

that can only be provided by an ex-<br />

perienced driller.<br />

Drilling by the cable-tool Fer-<br />

cussion method in unconsolidated<br />

format ions requires that the casing<br />

Fig.5.16 DISCHARGING DART cfosefy follows the drilling bit as tile<br />

VALVE BAILER. hole is deepened. This is necessary<br />

to prevent caving. <strong>The</strong> usual pro-<br />

cedure is to dig a starting hole into which is placed the first section of casing.<br />

<strong>The</strong> casing is driven one to several feet into the formation. water added <strong>and</strong><br />

the material within the casing drilled to a slurry <strong>and</strong> removed by bailing. <strong>The</strong><br />

casing is then driven again <strong>and</strong> the material within it watered if necessary.<br />

drifted <strong>and</strong> removed by b:tifing. <strong>The</strong> procedure is repeated, adding lengths ot<br />

casing until the desired depth is reached<br />

<strong>The</strong> pipe dliviug op i-iiiiiiiii iCcjLiiiCS ikit iI12 IoWcr C;:d of the first section<br />

of the casing be fitted wit11 a protective casing shoe (Fig. 5.18). Tile top of<br />

the casing is fitted with a drive head which serves as an anvil. Drive clamps<br />

made of two heavy steel forgings <strong>and</strong> clamped to the upper wrench square of<br />

the drill stem are used as the hammer (Fig. 5.19). <strong>The</strong> string of tools. which pro-<br />

vide the necessary weight for drivin g. is lifted <strong>and</strong> dropped repeatedly by the<br />

spudding action of the drilling machine. thus driving the casing into the<br />

ground. An alternative method of driving small diameter well casing uses a<br />

drive block assembly as prL>viousfy shown in Fig. 5.4. <strong>The</strong> drive block is raised<br />

<strong>and</strong> dropped onto the drive head by means of manila rope wound on a cat head.<br />

It is important that the first 40 to 60 feet of casing be driven vertically.<br />

Proper aiignment of the string of tools centrally within the casing. when the<br />

tools are allowed to hang freely. is a necessary precaution. Periodic checks


should be made with a plumb bob or carpenter’s level used along the pipe at<br />

two positions approximately at right angles to each other to ensure that a<br />

straight <strong>and</strong> vertical hole is being drilled.<br />

Cable-tool percussion drilling can be used successfully in all types of for-<br />

mations. It is. however. better suited than other methods to drilling in uncon-<br />

solidated formations containing large rocks <strong>and</strong> boulders.<br />

<strong>The</strong> main disadvantages of the cable-tool percussion method are its slow<br />

rate of drilling <strong>and</strong> the need to case the hole as drilling progresses. <strong>The</strong>re are.<br />

however, a number of advantages that account for its widespread use. Reason-<br />

ably accurate sampling of formation material can be readily achieved. Rough<br />

checks on the water quality <strong>and</strong> yield from each water-bearing stratum can<br />

readily be made as drilling proceeds. Much less water is needed for drilling<br />

than for the hydraulic rotary <strong>and</strong> jetting methods. This can be an important<br />

Fig. 5.17 SAND PUMP BAILER WITH<br />

FLAT VALVE BOTTOM.<br />

69<br />

consideration in arid regions. Any<br />

encounter with water-bearing for-<br />

mations is readily noticed as the<br />

water seeps into the hole. <strong>The</strong><br />

driller, therefore, need not be as<br />

skilled as his rotary counterpart in<br />

some respects.<br />

INSTALLING WELL CASING<br />

Some well drilling methods such<br />

as the cable-tool percussion method<br />

require that the casing closely fol-<br />

lows the drill bit as drilling pro-<br />

ceeds. In wells constructed by those<br />

methods, the casing is usually driven<br />

into position by any of the methods<br />

already described. This section deals<br />

with the setting of casing in an<br />

open borehole drilled by the hy-<br />

draulic rotary, jetting, hydraulic per-<br />

cussion or sludger methods.<br />

It is first necessary to ensure<br />

that the borehole is free from ob-<br />

structions throughout its depth be-<br />

fore attempting to set the casing. In<br />

the hydraulic rotary <strong>and</strong> jetting<br />

methods, the driller may ensure a<br />

clean hole by maintaining the fluid<br />

circulation with the bit near the<br />

bottom of the hole for a long<br />

enough period to bring all cuttings<br />

to the surface. At times, the driller<br />

may also drill the hole a little<br />

deeper than necessary so that any<br />

caving-material fills the extra depth


.I<br />

Fig. 5.18 CAStbiG DRIVE SHOE.<br />

of the hole without affecting the<br />

settirkg ui‘ the casing at the dcsircd<br />

depth.<br />

In setting casing. it may be sus-<br />

pended from witllin a coupling at<br />

its top end by means of an adapter<br />

called a sub which is attached to a<br />

hoisting plug (Fig. 5.X), a casing<br />

elevator (Fig. 5.2 1) or a pipe clamp<br />

placed around the casing below the<br />

coupling. <strong>The</strong> first length of casing<br />

is lowered until the coupling. casing<br />

elevator or pipe clamp rests on the<br />

rotary table or other support placed<br />

on the ground around the casing. If<br />

lifting by means of a sub. the sub on the first length of casing is unscrewed<br />

<strong>and</strong> attached to the second length of casing. If lifting by elevators or pipe<br />

clamps, then the elevator bails or their equivalent are released from the casing<br />

in the hole <strong>and</strong> fixed to another elevator or pipe clamp on the second length<br />

of casing. This length of casing is then lifted into position <strong>and</strong> screwed into<br />

the coupling of the first length. <strong>The</strong> threads of the casing <strong>and</strong> coupling should<br />

be lightly coated with a thin oil. Joints should be tightly screwed together to<br />

prevent leakage. <strong>The</strong> elevator or otfler support for the casing is then removed<br />

<strong>and</strong> the string of casing lowered <strong>and</strong> supported at its uppermost coupling. <strong>The</strong><br />

procedure is repeated for as many successive lengths of casing as are to bc<br />

installed. Should caving be such as to prevent the lowering of the casing, the<br />

swivel may be attached to the casing with a sub <strong>and</strong> by circulating tluid<br />

through the casing wash it down. Alternatively, the c:~ing may be driven.<br />

;#j$$<br />

”<br />

,,__ _,‘ ,/Y, _<br />

Fig.219 DRIVING CASING WITH<br />

DRIVE CLAMPS AS HAM-<br />

MER AEiD DRIVE HEAD AS<br />

ANVIL.<br />

70<br />

GROUTING AND SEALING<br />

CASING<br />

Grolitil2g is the name given to<br />

the process by which a slurry or<br />

watery mixture of cement or clay is<br />

used to fill the annular space between<br />

the casing <strong>and</strong> the wall of the<br />

borehole to seal out contaminated<br />

waters from the surface <strong>and</strong> other<br />

strata above the desirable aquifer.<br />

Should the well be constructed<br />

with both an inner <strong>and</strong> outer permanent<br />

casing, then the space between<br />

the casings as well as that between<br />

the wall of the borehole <strong>and</strong><br />

the outer casing should be grouted.<br />

Puddled native cluy of the type<br />

suitable for use as drilling fluid can


Fig. 5.20 HOKTING PLUG. (From Fig.<br />

5 1 Wk. Dcpartmcnt of the<br />

Army I cchnical <strong>Manual</strong> TM5-<br />

297. 19.57.)<br />

Fig. 5.2 I CASING ELEVATOR.<br />

71<br />

be used for glcruting <strong>and</strong> may be<br />

placed by pumicing with the mud<br />

circulation pundit nvrmally used for<br />

drifting purpose\ 1 I should he used<br />

at depths belt)\\ the first few feet<br />

from the surtlli< where it would<br />

not be subject to drying <strong>and</strong> shrinkage.<br />

It should 11kbt he used at depths<br />

where water nncjc,ement is likely to<br />

wash the clay p,;!iicfes away.<br />

ctv?ltw t p-t ) i l is the type most<br />

commonly ust.~~ irld is the subject<br />

of the renisind~ 01‘ this section. It<br />

is made by rlxslng water <strong>and</strong><br />

cement in the I;I~IO of 5 to 6 gaitons<br />

of water to a cU-tb sack of portl<strong>and</strong><br />

cement. This mixture is usually<br />

fluid enough to tlvw through grout<br />

pipes. Quant ir Ic’\ ot‘ water 1nuc11 in<br />

excess of h gallons per sack of cenient<br />

result in the settling out ot<br />

the cement. wll1~11 is undesirable. It<br />

is better toaim t‘or the drier mixture<br />

based on the Io~ver quurltity of‘ 5<br />

gallons of water peg- sack ot‘ c‘ement.<br />

A better tloiving tnisture may be<br />

obtained by uddtng 3 to 5 pounds<br />

of bentonite cla>. per sack ot‘ cement.<br />

in which case about 6.5 gallons<br />

of water 1’;‘;’ sack should be<br />

used. Where tl1.i ,!~ce to be filled is<br />

large. s<strong>and</strong> 111.l he added to the<br />

slurry to provli cstra bulk. This,<br />

however. incrc.t \ the difficulty 01<br />

placing <strong>and</strong> 11. iifirlg. <strong>The</strong> water<br />

used in tfle m~\~l.~rc should be free<br />

of oil or other oIg2nic material sucfi<br />

as plant leaves dnd bits of wood.<br />

Cement of either the regular or<br />

rapid-hardening r>.pe would be satisfactory.<br />

llse ot‘ r/12 latter perrnits an<br />

earlier resump’ of drilling operat<br />

ions.<br />

Mi3iug of rl~ I out may be done<br />

in a concietc hxr, if available,<br />

<strong>and</strong> batches stir’ _i temporarily until<br />

enough is nli ted for the job at<br />

h<strong>and</strong>. <strong>The</strong> quanlit ies normally re-


Fig. 5.22 A GRAVITY PLACEMENT<br />

METHOD OF CEMENT<br />

GROUTING WELL CASING.<br />

PLUGGED CASING LOWER-<br />

ED INTO CEMENT SLURRY<br />

FORCES SLURRY lNT0 AN-<br />

NULAR SPACE.<br />

quired for small wells can, however,<br />

be adequately mixed in a clean<br />

SO-gallon oil drum. To 20 gallons of<br />

water in the drum should be slowly<br />

sifted 4 sacks of cetnent while the<br />

water is being vigorously stirred<br />

with a paddle.<br />

Placirzg of the grout should be<br />

carried out in one continuous oper-<br />

ation before the initial set of the<br />

cement occurs. Regardless of the<br />

method of placing employed, the<br />

grout should be introduced at the<br />

bottom of the hole so that bY<br />

working its way up the annular<br />

space fil!s it completely without<br />

leaving any gaps. <strong>Water</strong> or drilling<br />

mud should be pumped through the<br />

casing <strong>and</strong> up the annular space to<br />

clear it of any obstructions before<br />

placing the cement grout. To do<br />

this. the top of the casing must be<br />

suitably capped. If the borehole has<br />

been drilled much deeper than the<br />

depth to which the casing is being<br />

set. then the extra depth below the<br />

casing tnlty be back-filled with a<br />

fine s<strong>and</strong>. <strong>The</strong>re are several methods<br />

of placing grout. of which ;1 few of<br />

the simpler ones are described be-<br />

low. Suitable pumps. air or water<br />

pressure may be used to force the grout into the annular space. However,<br />

grout may also be placed in shallow boreholes by gravity.<br />

A gruvit~~ p~accrmwt m~tiwd is indicated in Fig. 5.22. A quantity of slurry<br />

in excess of that required to fill the annular space is introduced into the hole.<br />

<strong>The</strong> casing with its lower end plugged with easily drillable material (soft wood<br />

for example) <strong>and</strong> with centering guides is then lowered into the hole, forcing<br />

the slurry upwards through the annular space <strong>and</strong> out at the surface. <strong>The</strong><br />

casing can be filled with water or weighted by other means to help it sink <strong>and</strong><br />

displace the slurry. If temporary outer casing is used. it should be withdrawn<br />

while the grout is still fluid.<br />

<strong>The</strong> imide-trrbir~g method for grouting well casing is shown in Fig. 5.23.<br />

<strong>The</strong> grout is placed in the bottom of the hole through ;1 grout pipe set inside<br />

the casing <strong>and</strong> is forced up the annular space either by gravity. or preferably<br />

by pumped pressure in order to complete the operation before the initial set<br />

of the cement occurs. Grouting must be continued until the slurry overflows


Fig. 5.23 INSIDE-TUBING METHOD<br />

OF CEMENT GROUTING<br />

WELL CASING.<br />

the top of the borehole. A suitable<br />

packer or cement plug fitted with a<br />

ball valve is provided to the bottom<br />

end of casing to prevent leakage of<br />

the grout up the inside of the<br />

casing. This packer too must be<br />

made of easily drillable materials.<br />

<strong>The</strong> grout pipe should be -% inch or<br />

larger in diameter <strong>and</strong> the casing<br />

filled with water to prevent it from<br />

float in:. <strong>The</strong> diameter of the drilled<br />

hole should be at least 2 inches<br />

larger than that of the well casing.<br />

<strong>The</strong> outside-tuhitzg method<br />

shown in Fig. 5.24 requires a bore-<br />

hole 4 to 6 inches larger in diameter<br />

than the well casing. <strong>The</strong> casing<br />

must be centered in the hole <strong>and</strong><br />

allowed to rest on the bottom of it.<br />

<strong>The</strong> grout pipe, of similar size to<br />

that used in the inside-tubing<br />

method, is initially extended to the<br />

bottom of the annular space <strong>and</strong><br />

should remain submerged in the slurry throughout the placing operations.<br />

This pipe may be gradually withdrawn as the slurry rises in the annular space.<br />

Should grouting operations be interrupted for any reason, the grout pipe<br />

should be withdrawn above the placed grout. Before lowering the pipe into<br />

the slurry again, grout should be used to displace any air <strong>and</strong> water in the<br />

pipe. <strong>The</strong> slurry is best placed by pumping, though it can be done by gravity<br />

flow. <strong>The</strong> casing may be plugged <strong>and</strong> weighted with water to prevent it from<br />

floating. <strong>The</strong> we@ of the drilling tools may also be used to keep the casing<br />

in place.<br />

After cement grout has been placed, no further work should be done on<br />

the weIl until the grout has hardened. <strong>The</strong> time required for hardening may<br />

be determined by placing a sample of the grout in an open can <strong>and</strong> sub-<br />

merging it in a bucket of water. When the sample has firmly hardened, work<br />

may proceed. Generally, a period of at least 72 hours should be allowed for<br />

cement grout to harden. If rapid-hardening cement is used, the time may be<br />

reduced to about 36 hours.<br />

WELL ALIGNMENT<br />

Alignment is being used here to include both the concepts of plumbness<br />

<strong>and</strong> straightness of a well. It is important to underst<strong>and</strong> these concepts <strong>and</strong><br />

how they differ. Plumbness refers to the variation with depth of the center<br />

line of the well from the vertical line drawn through the center of the well at<br />

the top of the casing. Straightness, however, melely considers whether the<br />

center line of the weli is straight or otherwise. Thus, a well may be straight<br />

73


Fig. 5.24 OUI’SIDE-TUBING METHOD<br />

OF CEMENT GROUTING<br />

WELL CASING.<br />

but not plumb, since its alignment<br />

is displaced in some direction or<br />

other from the vertic;il.<br />

Plumbness <strong>and</strong> straightness of a<br />

well are important cr)nsiderations<br />

of well construction because they<br />

determine whether a vertical<br />

turbine or subtnersible put~ip of a<br />

givert size can be installed in the<br />

well at a given depth. In this re-<br />

spect, straightness is the more im-<br />

portant fsctor. While 3 vertical<br />

pump can be installed in a reason-<br />

ably straight well that is not plumb,<br />

it cannot be insta!led in a well that<br />

is crooked beyond a certain limit.<br />

Plumbness must, however. be con-<br />

trolled within reasonable limits.<br />

since the deviation tram the vertical<br />

can affect the operation <strong>and</strong> life of<br />

some pumps. Most well construc-<br />

tion codes <strong>and</strong> drilling contracts<br />

specify limits for the alignment of<br />

large diameter, deep wells. Gener-<br />

ally, these limits cannot be practi-<br />

cably applied to stnall diameter,<br />

shallow wells. <strong>The</strong>se latter wells<br />

should merely be required to be<br />

sufficiently straight <strong>and</strong> piumb to permit the installation <strong>and</strong> operation of<br />

the pumping equipment.<br />

Conditions Affecting <strong>Well</strong> Alignment<br />

While it is desirable that a well be absolutely straight <strong>and</strong> plumb, this ideal<br />

is not usually achievable. Various conditions such as the character of the<br />

subsurface material being drilled, the trueness or straightness of the drill pipe<br />

<strong>and</strong> the well casing, <strong>and</strong> the pulldown force on the drill pipe in rotary drilling<br />

combine to cause variations from true straightness <strong>and</strong> plutnbness. Varying<br />

hardness of materials being penetrated can deflect the bit from the vertical.<br />

So can boulders encountered in glacial drift formations. A straight hole can-<br />

not be drilled with crooked drill pipe. Too much force applied at the top end<br />

of the rotary drill stem will bend the slender column of drill pipe <strong>and</strong> cause a<br />

crooked hole. Weight. in the form of drill collars, placed at the lower end of<br />

the drill stem just above the bit, however. will help to overcome the tendency<br />

to drift away from the vertical. Even after the borehole is drilled, bent or<br />

crooked casing pipes <strong>and</strong> badly aligned threads on them can result in a well<br />

with appreciable variations from thz vertical <strong>and</strong> straight lines.<br />

74


Measurement of <strong>Well</strong> .4lignment<br />

hleasurement of alignment is usuall>~ .dune in the cased b~~rehc~it;. Wll~r~<br />

drilling has been b>, the rotary method these 1ne;1surc1nc1~ts sh~~uld be made<br />

before the casing is grouted dl:d sealrd. For the txbl~-tool pcrcnssion <strong>and</strong><br />

orhcr methods in which the casing follows the bit as drilling progresses. peri-<br />

odic checks can be made on tfle plurnbrress <strong>and</strong> strsiglltness during drilling.<br />

Whena cable-tool hole has been started with the pools suspended directly ovei<br />

the center of the top of the c‘;lsin g. then any subsequent deviation ot‘ the cable<br />

from the center indicates 3 deviation of the hole from the vertical. <strong>The</strong> wear-<br />

irlg of the.corners of the cable-tool percussion bit on one side only also serves<br />

to indicate that 3 crooked hole is being drilled. <strong>The</strong>se early indications help a<br />

driller to take steps to correct the fault. He may find it necessary to change<br />

the position of the drillilig rig or backfill ;t portion of the hole <strong>and</strong> redrill it.<br />

A plumb bob suspended by wire cable from the derrick of the drilling rig<br />

or from ;1 tripod is usually used to measure both straightness <strong>and</strong> plumbness<br />

of ;L weit. <strong>The</strong> plumb bob should be in the form of 3 cvlinder 4 to h inches<br />

long with outside diameter about ‘4 inc*h smaller than t-he inside dittmeter of<br />

the casing. !t should be heave enough to stretch the wire cable taut. A guide<br />

block is fixed to the derrick ;r tripod so that the center of its small sheave L)I<br />

pulley is 10 feet above the top of the asin g <strong>and</strong> adjusted so that the plumb<br />

bob hangs exactly in the center of tile casing. <strong>The</strong> wire cable should be ac-<br />

curately marked at IO-ft. intervals.<br />

When the plumb bob is lowered to ;I particular IO-ft mark below the top<br />

of the casing the measured deviation of the wire line from the center of the<br />

top of the casing multiplied by 3 number that is one unit larger than that of<br />

the number of IO-ft sections of able in the casing gives the deviation at the<br />

depth 01‘ the plumb bob. For example. if the deviation from the center at the<br />

lop c:t rhe casing is !/X inch when the plumb bob is 3C feet be!ow the top of<br />

the casing. then the deviation from the vertical at 30 feet depth in the casing<br />

is three plus one. or four. times l/S inch. that is I/J inch. Similarly. with the<br />

plumb bob 40 feet in .the hole. the multiplier is five, <strong>and</strong> when 100 feet, the<br />

multiplier is eleven.<br />

7‘0 determine the straightness. the deviation is measured at I ‘3-ft intervals<br />

in the wc1I. If the deviation from the vertical increases by the UIIIC amount<br />

for each succeeding IO-ft interval. then the well is straight as CJr as the last<br />

depth checked. <strong>The</strong> calculated deviation or drift from the vertical may be<br />

plotted against depth to give a graph of the position of the axis or center line<br />

of the well. Such a graph can be used to determine whether ;I pump of given<br />

length <strong>and</strong> diameter can be placed at a given depth in the well. This can also<br />

be checked on site by lowering inro rhe well a “dummy” length of pipe ot<br />

the same dimensions ;IS the pump.<br />

INSTALLATION OF WELL SCREENS<br />

<strong>The</strong>re are several methods of installing well screens, some of which are<br />

described below. <strong>The</strong> choice of method for ;1 pxficular well Inay be intluenced<br />

by the design of the well, the drillin g method <strong>and</strong> the tvpe of problems en-<br />

countered in the drilling operrltion.<br />

75


Pull-back Method<br />

<strong>The</strong> pull-back method is by far the safest <strong>and</strong> simplest method used. While<br />

it is commonly used in wells drilled by the cable-tool percussion method, it is<br />

equally applicable in rotary drilled wells. <strong>The</strong> screen is lowered within the<br />

casing, which is then pulled back a sufficient distance to expose the screen.<br />

<strong>The</strong> screen must be the telescope type with outside diameter sized just sufficiently<br />

smaller than the inside diameter of the casing to permit the telescoping<br />

of the screen through the casing. <strong>The</strong> top of the screen is fitted with a<br />

lead packer which is swedged out to make a s<strong>and</strong>-tight seal between the top<br />

of the screen <strong>and</strong> the inside of the casing.<br />

<strong>The</strong> basic operations in setting a well screen by the pull-back method are<br />

indicated in the series of illustrations in Fig. 5.25. <strong>The</strong> casing is first sunk to<br />

the depth at which the bottorn of the screen is to be set. Any s<strong>and</strong> or other<br />

cuttings in the casing must be removed by bailing or washing. <strong>The</strong> screen is<br />

then assembled. suspended within the casing, following which the hook<br />

shown in Fig. 5.26 is caught in the bail h<strong>and</strong>le at the bottom of the screen.<br />

<strong>The</strong> whole assembly is then lowered on the hoist line to the bottom of the<br />

hole. If the depth to water level in the hole is less than 30 feet, however, the<br />

assembled screen may simpi,w _ he dropped in the casing. Having checked to<br />

Fig. 5.25 PULL-BACK METIIGD OF SETTING WELL SCREENS.<br />

A. Casing is sunk to full depth of well.<br />

B. <strong>Well</strong> screen is lowered inside casing.<br />

C. Casing is pulied back to expose screen in water-bearing formation.<br />

76


Fig. 5.26 LOWERING HOOK.<br />

Fig. 5.27 B U M PI N G BLOCK BEING<br />

USED TO PULL WELL CAS-<br />

ING.(From Bergerson-Caswell,<br />

Inc. , Minneapolis, Minnesota.)<br />

ascertain the exact positron of<br />

screen, the hook is released <strong>and</strong><br />

withdrawn. A string of small pipe is<br />

then run into <strong>and</strong> allowed to rest<br />

on the bottom of the screen to hold<br />

it in place white the casing is being<br />

pulled back to expose the screen. If<br />

the casing has been driven by the<br />

cable-tool percussion method, then<br />

it may be pulled by jarring with the<br />

drilling tools or with a bumping<br />

block, the latter of which is shown<br />

in Fig. 5.27. It may even be pos-<br />

sible in some instances to pull the<br />

casing with the casing line on the<br />

drilling machine. I’vlechanicd or<br />

hydraulic jacks (Fig. 5.38) may also<br />

be used in combination with a pull-<br />

ing ring or spider with wedges or<br />

slips. <strong>The</strong> casing should be pulled<br />

back far enough to leave its bottom<br />

end 6 inches to 1 foot below the<br />

lead packer. <strong>The</strong> pipe holding the<br />

screen in place is removed <strong>and</strong> a<br />

swedge block (Fig. 5.29) used to<br />

exp<strong>and</strong> the lead packer <strong>and</strong> create a<br />

s<strong>and</strong>-tight seal against the inside of<br />

the casing. To do this. two or three<br />

iengths of small diameter pipe are<br />

screwed to the sliding bar which<br />

passes through the swedge block.<br />

<strong>The</strong> assembly is lowered into the<br />

well until the swcdge block rests on<br />

the lead packer. <strong>The</strong> weight pro-<br />

vided by the pipe attached to the<br />

sliding bar is then lifted 6 to 8<br />

inches <strong>and</strong> dropped several times.<br />

<strong>The</strong> swedge block itself should not<br />

be lifted off the lead packer. It<br />

should be simply forced down into<br />

the packer by the repeated blows<br />

of the weighted sliding bar.<br />

Open Hole Method<br />

<strong>The</strong> open hole method illustrated in Fig. 5.30 involves the setting of the<br />

screen in an open hole drilled below the previously installed casing. <strong>The</strong><br />

method is applicable to rotary drilled wells. .<br />

77


Wash line-<br />

.Cemsnt grout ,’<br />

Exo<strong>and</strong>ed .?:i<br />

leab pucker<br />

Drilling mud<br />

Wrtially<br />

washing L<br />

Fig. 5.30 SETTING WELL SCREEN IN OPEN HOLE DRILLED BELOW THE WELL<br />

CASING.<br />

Fig. 5.31 LEAD SHOT AND LEAD WOOL FOR PLUGGING OPEN BOTTOM END OF<br />

WELL SCREEN.<br />

r


maintaining such 3 “dean” hole. ;1 short extension pipe may be attached to the<br />

bottom of 311 open-ended screen to permit washing it down with drilling fluid.<br />

<strong>The</strong> bottom of the extension pipt’ is then plugged with lead shot, lead wool<br />

( Fig. 5.3 I ) or cement grout <strong>and</strong> the lead pucker exp<strong>and</strong>ed after circulating wa-<br />

ter to wash some of the drillins mud out of the hole. Lead wool or cement<br />

grout should be tamped ifor comprtction. If lead shot is used. it is simply poured<br />

in sufficient qu:tntity to form ;I 4 to ti-inch thick layer inside the extension pipe.<br />

Wash&w Method<br />

<strong>The</strong> wash-down method of instttllation (Fig. 5.32) uses a high velocity jet<br />

of Ii&t-weight drilling mud or water issuing from a special washdown<br />

bottom fit ted to the end of the screen to loosen the s<strong>and</strong> :md create ;1 hole in<br />

which the screen is lowered.<br />

<strong>The</strong> washdown bottom is a self-closing ball valve. A string of wash pipe is<br />

connected to it <strong>and</strong> used to lower the entire screen assembly through the<br />

casing which has been previously cemented. As the screen is washed into<br />

position. the loosened s<strong>and</strong> rises around the screen <strong>and</strong> up through the asing<br />

Fig. 5.32 WASH-DOWN METHOD OF<br />

SETTING WELL SCREEN.<br />

X0<br />

<strong>Well</strong> rcrrrn<br />

Coupling on uaah pipe<br />

fun18 In conkot aoat<br />

Combination back-<br />

Fig. 5.33 JETTING WELL SCREEN IN-<br />

TO POSITION.


to the surface with the return flow. S<strong>and</strong> particles which inevitably accumu-<br />

late in the well screen must be washed out of it once the screen is in final<br />

position. <strong>Water</strong> should later be circulated at a reduced rate to remove any<br />

wall cake formed in the hole during the jetting operation. This causes the<br />

formation to cave around the screen <strong>and</strong> grip it firmly enough for the wash<br />

line to be disconnected.<br />

it is common practice in jetted <strong>and</strong> rotary drilled small wells to set a<br />

combined string of casing <strong>and</strong> screen, permanently attached. in one IJperation.<br />

A jetting method for setting such a combined string is illustrated in Fig. 5.33.<br />

<strong>The</strong> scheme employs the use of a temporary wash pipe assembled inside the<br />

well screen before attaching the screen to the bottom length of casing. A<br />

coupling attached to the lower end of the wash pipe rests in the conical seat<br />

in the wash-down bottom. A close-fitting ring seal made of semi-rigid plastic<br />

material or wood faced with rubber is fitted over the top end of the wash<br />

pipe <strong>and</strong> kept in position by the coupling above it. <strong>The</strong> seal prevents any re-<br />

turn flow of the jetting water in the space between the wash pipe <strong>and</strong> the<br />

screen. All the return flow from the washing OL jetting operation, therefore,<br />

takes place outside of the screen <strong>and</strong> casing. A little leakage of the jetting wa-<br />

ter takes place around the bottom of the wash-pipe <strong>and</strong> out through the<br />

screen, thus preventing the entry of fine s<strong>and</strong> into the screen. Maintaining<br />

this small outward flow through the screen is important, since it reduces the<br />

possibility of s<strong>and</strong>-locking the wash pipe in the screen.<br />

With the casing <strong>and</strong> screen assembly washed into final position, fluid circu-<br />

lation is stopped. <strong>The</strong> plastic ball then floats up into the seat, thus effectively<br />

closing the valve opening in the washdown bottom. A tapered tap, overshot<br />

or some other suitable fishing tool (see later section of this chapter on fishing<br />

tools) is then used to fish the wash pipe <strong>and</strong> ring seal out of the screen. It<br />

may also be possible to recover the wash pipe assembly by tapping the<br />

coupling with pipe carrying regular pipe threads instead of a tapered tap. <strong>The</strong><br />

well is then ready for development.<br />

Satisfactor> penetration by this method requires continuous circulation<br />

when water is used as the jetting fluid. This may limit the use of the method<br />

to the penetration of only as much screen <strong>and</strong> casing as it is physically pos-<br />

sibie to assemble as a single string in an upright position with the available<br />

drilling equipment. Subsequent additions of casing will require interruptions<br />

of the circulation that can lead to the collapse of the drill hole (particularly<br />

in water-bearing s<strong>and</strong>s <strong>and</strong> gravels) around the combined string of screen <strong>and</strong><br />

casing thus preventing further penetration. This problem may be avoided by<br />

the use of a suitable driIling mud. <strong>The</strong> method is very often used for washing<br />

screens into position below previously drilled boreholes. If the borehole has<br />

already been drilled into the aquifer to the full depth of the well, then the<br />

wash-down bottom may be u3ed on the screen without the wash pipe.<br />

<strong>Well</strong> Points<br />

<strong>Well</strong> points can be <strong>and</strong> are often installed in drilled wells by some of the<br />

methods just described in this section. <strong>The</strong> pull-back <strong>and</strong> open hole methods<br />

would be particularly applicable. Where, because.of excessive friction on the<br />

casing or a heaving s<strong>and</strong> formation. the pull-back method is impracticable, a


well point may be driven into the formation below the casing by either of the<br />

methods shown in Fig. 5.34 or Fig. 5.35. In the method of Fig. 5.35 the driv-<br />

ing force is transmitted through the driving pipe directly onto the solid poitlt<br />

of the screen. This method is preferable, therefore, when driving relatively<br />

long well points. In both cases the hole is kept full of water while the screen<br />

is being set in heaving s<strong>and</strong> formations.<br />

ttrtificially Gravel-Packed <strong>Well</strong>s<br />

<strong>The</strong> methods of screen installation so far described apply primarily to<br />

wells to be completed by natural development of the s<strong>and</strong> formation. One<br />

of &ese, the pull-back method, can, with little modification, be used in<br />

artificiaiiy gravel-packed wells.<br />

An artificidil!y gravel-packed well has an envelope of specially graded s<strong>and</strong><br />

Fig.5.34 DRIVING WELL POINT<br />

WITH SELF-SEALING PACK-<br />

ER INTO WATER-BEARING<br />

FORMATION.<br />

<strong>Well</strong> casing -\ ’ ‘Q/I<br />

Drlvlng pipe<br />

Fig. 5.35 DRIVING BAR USED TO DE-<br />

LIVER DRIVING FORCE<br />

DIRECTLY ON SOLID BOT-<br />

TOM OF WELL POINTS 5 Fi-<br />

OR MORE IN LENGTH.


-Inner Carm~<br />

Fig. 5.36 DOUBLE-CASING METHOD<br />

OF ARTIFICIALLY GRAVEL<br />

PACK!,% A WELL. GRAVEL<br />

IS ADDED AS THE OUTER<br />

CASING IS PULLED BACK<br />

FRO:4 THE FULL DEPTH<br />

OF I-HE WELL;<br />

or gravel placed around the well<br />

screen in a predetermined thick-<br />

zess. This envelope takes the piace<br />

of the hydraulically graded zone of<br />

highly permeable material produced<br />

by conventionti development pre-<br />

cedures. Conditions that requil-c the<br />

use of artificial gravel packing have<br />

been described in the previous<br />

chapter.<br />

<strong>The</strong> modified pull-back method<br />

known as the double-casing method<br />

involves centering a string of casing<br />

<strong>and</strong> screen of equal diameter within<br />

an outer casing of a size corre-<br />

sponding to the outside diameter of<br />

the gravel pack (Fig. 5.36). This<br />

outer casing is first set to the full<br />

depth of the well. <strong>The</strong> inner casing<br />

<strong>and</strong> screen should be suspended<br />

from the surface until the place-<br />

ment of the gravel pack is com-<br />

plcted. <strong>The</strong> selected gravel is put<br />

in place in the annular space<br />

around the screen in bax!?es of a<br />

few feet. following each of which<br />

the outer casing is pulled hack an<br />

appropriate distance <strong>and</strong> the pro-<br />

cedure repeated until the level of<br />

the gravel is well above the top of<br />

the screen. <strong>The</strong> well may then be<br />

developed to remove any fine s<strong>and</strong><br />

from the gravel <strong>and</strong> any mud cake that may have formed on the surface<br />

between the gravel <strong>and</strong> the natural formation, <strong>The</strong> method can be used in both<br />

cable-tool percussion <strong>and</strong> rotary drilled wells.<br />

Care must be taken in placing the gravel to avoid separation of the coarse<br />

<strong>and</strong> fine particles of the graded mixture. Failure to do so could result in a<br />

well that continually produces fine s<strong>and</strong> even though properly graded ma-<br />

terial has been used in the gravel pack. This tendency towards separation of<br />

particles of different sizes can be overcome by dropping the material in small<br />

batches or slugs through the confined space of a small diameter conductor<br />

pipe or tremie (Fig. 5.37). Under these confined conditions there is less ten-<br />

dency for the grains to fAl individually. <strong>Water</strong> is added with the gravel to avoid<br />

bridging in the tremie. <strong>The</strong> tremie. usually about _ ’ inches in diameter. is raised<br />

as the level of material builds up around the well screen. <strong>Water</strong> circulated in a<br />

reverse direction to that of normal rotary drilling that is down the annular<br />

space between the casings, through the gra\A <strong>and</strong> screen <strong>and</strong> up through the<br />

inner casing to the pump suction ~~ helps prevent bridging in the annular


Fig. 5.37 PLACING GRAVEL-PACK<br />

MATERiAL THROUGH PIPE<br />

USEDASTREMIE.<br />

Fig.538 LEAD SLIP-PACKER IN PO-<br />

SITION ON EXTENSION<br />

PIPE BEFORE EXPANSION<br />

TO SEAL THE ANNULAR<br />

SPACE.<br />

space as the gravel is being de-<br />

posited.<br />

Some settlement of the gravel<br />

will occur during the development<br />

process. More gravel must, there-<br />

fore. be added as is necessary to<br />

keep the top level of the gravel<br />

several feet above that of the<br />

screen. <strong>The</strong> entire length of the<br />

inner casing need not be le ‘t per-<br />

manently in the well if the outer<br />

one is intended to be permanent.<br />

Towards this end, a convenient<br />

joint in the inner casing can be<br />

loosely made up while assembling<br />

the string. After development of<br />

the well the upper portion of casing<br />

is then unscrewed at this joint <strong>and</strong><br />

withdrawn, leaving enough pipe (at<br />

least one length) attached to the<br />

screen to provide an overlap of a<br />

few feet within the outer CilSillg.<br />

Another technique would be to<br />

set the inner casing to the full<br />

depth of the well <strong>and</strong> telescope the<br />

screen <strong>and</strong> an appropriate length of<br />

extension pipe attached to the top<br />

of the screen into? that casing. <strong>The</strong><br />

entire string of inner casing nrrly<br />

then be removed as ths gravel is<br />

placed. !eaving the extension pipe<br />

overlapping inside the outer casing.<br />

Centering guides must be provided<br />

on the temporary inner casing.<br />

Cement grout, lead shot or pellets of lead wool can be llscd to seal the<br />

annular space immediately above the top of the gravel. A mechanical type ot<br />

seal known as a lead slip-packer (Fig. 5.38) is also often used. <strong>The</strong> packer. a<br />

lead ring of similar shape to a casing shoe, sits on top of the extension pipe<br />

<strong>and</strong> is of the proper diameter <strong>and</strong> wall thickness to form an effective seal<br />

when exp<strong>and</strong>ed by a swedge block against the outer casing.<br />

Recovering <strong>Well</strong> Screens<br />

It may sometimes be necessary to recover an encrusted screen for cleaning<br />

<strong>and</strong> return to the well, a badly corroded one for replacement or a good one<br />

from an ab<strong>and</strong>oned weil for reuse elsewhere. C‘onsiderable force may have to<br />

be applied to the screen to overcome the grip of the water-bearing s<strong>and</strong><br />

around it. <strong>The</strong> s<strong>and</strong>-joint method provides one of the best ways of transmitting<br />

this force to the screen, dislodging <strong>and</strong> recovering it without daE,aging it. <strong>The</strong><br />

x4


Lead packer<br />

Pulhg pipe<br />

S<strong>and</strong> join1<br />

Sacking<br />

wired on pipe<br />

<strong>Well</strong> screen<br />

Ball<br />

Fig. 5.39 ELEMENTS OF SAND-JOINT<br />

METHOD USED FOR PUL-<br />

LiNG WELL SCREENS.<br />

method, however, cannot be used<br />

in screens smaller than 4 inches in<br />

diameter.<br />

<strong>The</strong> s<strong>and</strong>-joint method uses s<strong>and</strong><br />

carefully placed in the annular<br />

space between a pulling pipe <strong>and</strong><br />

the inside of the well screen +o<br />

form a s<strong>and</strong> lock or s<strong>and</strong> joint<br />

which serves ‘is the structural con-<br />

nection between the pulling pipe<br />

<strong>and</strong> the screen (Fig. 5.39). <strong>The</strong><br />

necessary upward force may then<br />

be applied to the pulling pipe by<br />

means of jacks working against pipe<br />

ciamps or a pulling ring with slips as<br />

shown in Fig. 5 28.<br />

<strong>The</strong> size of the pulling pipe<br />

varies with the diameter of the<br />

scrl:en <strong>and</strong> the force wnich may be<br />

required. As a general rule, how-<br />

ever, the size of pipe is chosen at<br />

one-half the nominal inside diam-<br />

eter of the screen. For example, a<br />

4-inch screen with nominal inside<br />

diameter of 3 inches would require<br />

1 ?&inch pipe. Extra heavy pipe<br />

should be used. <strong>The</strong> pipe couplings<br />

<strong>and</strong> threads should be of the<br />

highest quality in order to with-<br />

st<strong>and</strong> the pullin, 0 force. <strong>The</strong> s<strong>and</strong><br />

should be clean, sharp <strong>and</strong> uniform<br />

material of medium to moderately tine size.<br />

<strong>The</strong> first step in the preparation of the s<strong>and</strong> joint is the tying of Z-inch<br />

strips of sacking to the lower end of the pulling pipe immediately above<br />

a coupling or ring welded to the pipe (Fig. 5.40). <strong>The</strong> sacking forms a socket<br />

to retain the s<strong>and</strong> fill around the pulling pipe. <strong>The</strong> pipe <strong>and</strong> sacking with both<br />

ends tied to the pipe are then lowered into the casing until only the upper<br />

ends of the strips remain above the top of the casing. <strong>The</strong> string which holds<br />

the upper ends of the sacking to the pipe is then cut <strong>and</strong> the strips of sacking<br />

arranged evenly around the top of the casing as shown in Fig. 5.41.<br />

Next the pulling pipe is towered to a point near the botttim of the screen,<br />

care being taken to keep it as well centered as possible. <strong>The</strong> s<strong>and</strong> is then<br />

poured slowly into the annular space between the pulling pipe <strong>and</strong> the casing.<br />

An even distribution of the s<strong>and</strong> around the circumference of the pipe is de-<br />

sirable. <strong>The</strong> pulling pipe should be moved gently backward <strong>and</strong> forward at the<br />

top while pouring the s<strong>and</strong> to avoid bridging above couplings. A small stream<br />

of water playing onto the s<strong>and</strong> would also help in preventing bridging. Enough<br />

85


s<strong>and</strong> sflould be used to fill at least two-thirds bur not the entire IcIlgth oft hi\<br />

screen. <strong>The</strong> level of the s<strong>and</strong> in the screen an he ,hxked with ;I string ot‘<br />

small dismcter pipe used as a sounding rod.<br />

I:$. 5.40 STRlPS OF SACKlNG BElNG<br />

TIED TO LOWER END OF<br />

THE PULLING PIPE USED<br />

IN THE SAND-JOINT<br />

METHOD.<br />

<strong>The</strong> proper clu;intity of sdnd<br />

having been piaced, tt:e pulling pipe<br />

is then gradually lifted to a~rnpaut<br />

the s<strong>and</strong> <strong>and</strong> develop ;I fit-t*: + it, ~)II<br />

the inside surface of the screen.<br />

Additi!mal tension is applied until<br />

the screen begins tu mc)ve. <strong>The</strong><br />

screen may then he pulled steadily<br />

without difficulty until it is out ot<br />

the well. <strong>The</strong> s<strong>and</strong> joint can be<br />

broken at the surfxc by washing<br />

out the s<strong>and</strong> with a stream ot<br />

waler.<br />

Prc-fwatrtwt!t 01‘ the szrt‘cn with<br />

hydrochluric or muriut ic acid serves<br />

to loosen encrusting materials <strong>and</strong><br />

thus reduce the force rcctuired to<br />

obtain initial movement of the<br />

screen. Fur this purpose the sc‘reen<br />

is filled with a mixture of cqual<br />

amounts of acid ard water which is<br />

left IO st<strong>and</strong> for several hours, eve


saving that sb<strong>and</strong>unmcnt ot‘ the borehole or well \vuuld altail. Only :tf’ter<br />

such careful cctnsidcrtlt ion should t’islljrl~ operations be undcrtakcn. For<br />

smttll dirimeter, rclativelv shallow wells it wtbuld often be t’wnd t’co~~o~~wd<br />

<strong>and</strong> othcxwise bexitci 11 tLj drill 3 I~CW ~vell rather than attempt fislling<br />

opcrtltions in OIW under construction. This is particul;lrly true prior to the<br />

placing <strong>and</strong> cement Eng of the permtlnent casing. It should also bc borne in<br />

mind that fishing operations require :I great deal of skill, rnucl~ more so than<br />

drilling operation s <strong>and</strong> the driller rnrty be inexperienced in such work.<br />

Preventive Measures<br />

As is the crtst’ with all other forms ofxcidents. prevention is always bc: ter<br />

than curt. Towards this end, the necessity to exercise the greatest care <strong>and</strong><br />

attention at all times <strong>and</strong> throughout<br />

all stages of drilling operations<br />

cannot be over-stressed. While the<br />

utmost cat-e <strong>and</strong> attention will not<br />

completely eliminate the need for<br />

fishing. it will consider;rbly reduce<br />

the number <strong>and</strong> frequency of fishing<br />

optxrt ions.<br />

Among the precautions that<br />

should be undertaken is the propel<br />

care <strong>and</strong> use of drilling touls <strong>and</strong><br />

equipment. This includes the propel<br />

cleuning und brtxking-in of new<br />

tool joints. the proper cleaning<br />

<strong>and</strong> setting of joints at all times,<br />

the correct dressing <strong>and</strong> hardening<br />

of bits. the regular maintenance <strong>and</strong><br />

inspection of all wire rope. the regular<br />

inspection of all components<br />

of’ the drilling string for the development<br />

uf fatigue cracks <strong>and</strong> the<br />

discarding of worn out tools. Above<br />

all. cart! tnust be taken nevc’r tu<br />

overload equipment nor LLSC tools<br />

for purposes other than those for<br />

which they have been designed.<br />

<strong>The</strong> manut‘Hcturer’s limitations set<br />

UPPER END OF SACKING<br />

STRIPS ARRANGED EVEN-<br />

LY AROUND TOP OF WELL<br />

CASING AS THE PULLING<br />

PIPE IS LOWERED INTO<br />

THE. WELL.<br />

011 the use of equipment <strong>and</strong> tools<br />

should not be exceeded.<br />

<strong>The</strong> care of wire rope should be<br />

given special considerat ion. Many<br />

manufacturer’s catalogs contain detailed<br />

instructions. Among the most<br />

import ant of these is the need t,r<br />

regular lubrication with a good<br />

grade of lubricant. free from acid or<br />

x7


alkali <strong>and</strong> which will penetrate <strong>and</strong> adhere to the rope. <strong>The</strong> ust’ ot‘ crude<br />

oil or other material likely to be injurious to steel or ruse deterioratiorl<br />

or brittleness of the wires must be avoided. Failure to properly lubric’utt’<br />

wire rope results in the wires becomm~ brittle. corroded, subject to excessive<br />

friction wear <strong>and</strong> ultimatt4y the sud& fracturmg of the rope. <strong>The</strong> rope<br />

should be tightly <strong>and</strong> evenly wound on winding drums <strong>and</strong> should not be<br />

allowed to st<strong>and</strong> in mud. dirt or other such medium which is h~rmt‘ul to steel.<br />

Only proper P&sterling clamps that do nut kink. flatten or crush the rope<br />

should be used. <strong>The</strong> fracturing CJf loaded wire rope, it should be remem-<br />

bered, can cause serious injury tu workmen as well as create fishing problems.<br />

lrnscrewed tool joints are ihe causes of many fishing operations. <strong>The</strong>se can<br />

be avoided by the proper matirlg of the box <strong>and</strong> pin components of the<br />

joints. Both the pin shoulder <strong>and</strong> the box fi!ce should be thoroughly cleaned<br />

<strong>and</strong> free of imperfections that prevent a full <strong>and</strong> even contact. <strong>The</strong> threads<br />

<strong>and</strong> shoulders of the component parts should be thinly coated with a light<br />

machine oil before mttking up the joint. Joints should be firmly made up<br />

though not with excessive pressure as this cm result in broken boxes <strong>and</strong><br />

pins.<br />

Tools. carelessly left on the rotary table or at some such point. nwy be<br />

accidentally tipped into a borehole. One half of 9 pipe clamp entering ;I well<br />

in this manner has been known to become wedged iu the well sc’recn<br />

just above a juint in the wash pipe being used in the development pr~xxss<br />

<strong>and</strong> result not only in the ab<strong>and</strong>onment of the well but also the loss<br />

of several hundred feet of drill stern with it. All tools should be removed<br />

immediately after use to a convenient point of storage at ;I safe distance t’rom<br />

the borehole or well.<br />

Certain conditions such as slanting or caving formations. crooked holes<br />

<strong>and</strong> the presence of boulders often contribute to drilling troubles that may<br />

result in fishing operations. <strong>The</strong> utmost care must be exercised by drillers<br />

operating under these conditions.<br />

Prepmat ions for Fishing<br />

<strong>The</strong> nature of all operations (construction <strong>and</strong> maintenance) or1 wells is<br />

such that accidents do occur even under the supervision of the most capable<br />

<strong>and</strong> careful drillers. <strong>The</strong>refore, the driller in anticipation of the inevitable<br />

fishing job should record or have access to the exact dimensions of everything<br />

used in or around the well. This facilitates the selection <strong>and</strong> design of a<br />

suitable fishing tooi when necessary. All tools brought to the site should be<br />

accurately measured <strong>and</strong> the measurements properly recorded. Some of the<br />

important measurements are: the outside diameter <strong>and</strong> length of the rope<br />

socket; the diameter, length <strong>and</strong> stroke of the drill jars; the diameter <strong>and</strong><br />

length of the drill stem; the size of tool joints <strong>and</strong> the outside diameter <strong>and</strong><br />

length of the pin <strong>and</strong> box collars; the body size <strong>and</strong> length of bits; the length<br />

of pin collars on the bits. A careful record of the depth or the hole <strong>and</strong> the<br />

ovemil length of the drilling string is also essential for successful fishing<br />

operations.<br />

<strong>The</strong> drill hole must of necessity be larger than any tools placed in it. As a


esult, tools lost in a hole do not often remain in the vertical or upright<br />

position but become wedged in sloping positions across the hole. In addition,<br />

material from a caving formation may fall onto <strong>and</strong> cover the tool. No<br />

amount of measurement at the surface could teli the driller exactly what<br />

position the lost tool has assumed in the hole or. in some cases, whether the<br />

top portion of it is free from obstruction. It is, therefore. considered good<br />

practice to use what is known as a n impression block to obtain an impression<br />

of the top of the tool before at-<br />

- Drill pipe tempting any fishing operations.<br />

This is particularly necessary in<br />

rotary drilled, uncased holes. Impression<br />

blocks are of many forms<br />

<strong>and</strong> designs, one of which is shown<br />

in Fig. 5.32. A short block of wood<br />

(preferably soft wood) turned on a<br />

f-- Box pin<br />

lathe to a diameter about one inch<br />

less than that of the drilled hole <strong>and</strong><br />

with the upper portion shaped in<br />

the form of a pin, is driven to fit<br />

tightly into a drill pipe box collar.<br />

For added security. the wooden<br />

block should be wired or pinned<br />

securely to the collar. <strong>The</strong> wooden<br />

block may aiternative!y be bolted<br />

to the dart of a dart valve bailer. A<br />

quantity of small headed nails is<br />

driven into the bottom of the circular<br />

block, leaving an extension of<br />

about */4 inch. Sheet metal ir temporarily<br />

nailed around the block<br />

with a protrusion of a few inches<br />

over the lower end of the block.<br />

Warm paraffin wax, yellow soap or<br />

other plastic material is poured to<br />

fill thus protrusion <strong>and</strong> then left to<br />

cool <strong>and</strong> solidify. <strong>The</strong> nail heads<br />

help to hold the plastic material<br />

onto the block. After the sheet<br />

metal is removed <strong>and</strong> the lower end<br />

of the plastic material carefully<br />

smoothed, the impression block is<br />

ready for use. <strong>The</strong> block should be<br />

lowered carefully <strong>and</strong> slowly into<br />

Fig. 5.42 IMPRESSION BLOCK.<br />

the hole until the object is reached.<br />

It is then raised to the surface where<br />

the impression made in the wax or<br />

soap can be examined. By careful<br />

89


interpretation of the impression, a driller can determine fhc’ position of the<br />

fish <strong>and</strong> the best means of retrieving it.<br />

Common Fishing Jobs <strong>and</strong> Tools<br />

It is often said, with considerable justificatiun. that no IIVO fishing jobs are<br />

alike. While fishing jobs may be classified into various type-\, individual jobs<br />

within these types are usually quite different. Fishing jobs. ;IS ;L result. test the<br />

skill <strong>and</strong> ingenuity of the driller to the fullest extent. <strong>The</strong> driller relies on a<br />

number of basic principles in his attack on fishing problemh. A great variety<br />

of special tools have been devised to assist him in this work. Many of these<br />

toois are used very infrequently <strong>and</strong> it is not uncommon to i‘ind a tvol made<br />

for a particular job <strong>and</strong> never used again. Only large-scale drilling operators<br />

can afford to have more than a limited stock of fishing tooI>. Whenever pos-<br />

sible. small operators usually rent took as the>, are needed Q‘rum suppliers. It<br />

would be impractical to attempt a discussion of all types ot‘ fishing jobs <strong>and</strong><br />

the too!5 used on them. Instead, the discussion that follows centers on some<br />

of the more common types of fishing jobs <strong>and</strong> tools.<br />

t I ) Parted &ill pipe: One of the most frequent fishingjc&s in rotary drill-<br />

ing is that for the recovery of drill pipe twisted off in the hole. <strong>The</strong> break<br />

may either be due to shearing of the pipe or failure of a threaded joint.<br />

An impression block should first be used to determine the exact depth <strong>and</strong><br />

position of the top of the pipe. whether there has been any caving of the up-<br />

per formation material onto the top of the pipe or whether the pipe has be-<br />

come embedded into the wall of the hole. If the top of rhe pipe is unob-<br />

structed. then either the rapereclfishiqg tap or die o~~slzor could be effective<br />

if used before the cuttings in the hole settle <strong>and</strong> “freeze” the drill pipe. <strong>The</strong><br />

kwlatitg-slip overshot. which permits the circulation of drilling fluid, would<br />

be the best tooi to use after the pipe has been frozen by the settling of cut-<br />

tings around it. <strong>The</strong>se tools dre all illustrated in Fig. 5.43.<br />

<strong>The</strong> tapered fishing rap, made of heat-treated steel, tapers approximately 1<br />

inch per foot from a diameter somewhat smaller than the inside diameter of<br />

the coupling to a diameter equal to the outside diameter of the drill stem.<br />

<strong>The</strong> tapered portion is threaded <strong>and</strong> fluted the full length of the taper to<br />

permit the escape of chips cut by the tap. <strong>The</strong> tap is lowered slowly on the<br />

drill stem until it engages the lost pipe. the circulation being maintained at a<br />

low rate through the hole in the tap during this period. Having engaged the<br />

lost pipe, the circulation is stopped <strong>and</strong> the tap turned sltiwly by the rotary<br />

mechanism or by h<strong>and</strong> until the tap is threaded inio the pipe. An attempt<br />

should then be made to reestablish the circulation through the entire drill<br />

string before pulling the lost pipe.<br />

<strong>The</strong> de over&t is a long-tapered die of heat-treated steel designed to fit<br />

over the top end of the lost drill pipe <strong>and</strong> cut its own thread as it is rotated. It<br />

is fluted to permit iiIr: ~SLL~Z UT merai cu~ti~~gs. Circuiation cannot be corn-<br />

pleted to the bottom of the hole through the lost pipe since the flutes also<br />

allow the fluid to escape. <strong>The</strong> upper end of the tool has a box thread designed<br />

to fit the drill pipe.<br />

<strong>The</strong> circrdatirzg-slip overshot is a tubular tool approximately 3 feet long<br />

with inside diameter slightly larger than the outside diameter of the drill pipe.


Tapered Tap<br />

Die Overshot<br />

Circulating Slip Overshot<br />

<strong>The</strong> belled+ut lower portinjn ot‘ the tool helps to icntruliz <strong>and</strong> guide the top<br />

of the lost drill pipe into the slip shown fitted in tllc tapcrcd slcevc. <strong>The</strong> slot<br />

cut through one side ot‘ the slip cnahlcs it to ~syarld ;IS the tucrl is II)wered<br />

over the drill pipe. As the tol,l is raised the slip is pu!M rlowtl into the<br />

tapered sleeve, thus tightening tllc slop against the pipe. i’iruulatiorl ot’ tluid<br />

can then be established through ~he pipe. freeing it for recovery.<br />

A wall Izooli shown in Fig. 5.44 cm be used to set the lost drill pipe erect<br />

in the hole in preparation for the trip or overshot tools. Tile wall ho~~k is ;I<br />

simple tool that can be made from 2 suitable size of steel casing cut to shape<br />

with a cutting torch. A reducing sub must then be used to connect the top<br />

end of the tool to the drill stem. To operate the wall h~\jk, it is lowered until<br />

it engages the pipe. ,then slowly rotated until the pipe is fully within the<br />

hook. <strong>The</strong> hook is then raised slowly to set the pipe in art uptight positicjn.<br />

later disengaging itself from the pipe.<br />

It is also possible to pin a tapered fishing tap into the upper portion of 3<br />

wall hook made from steel casing. With such a combined tool. the hook may


e used to realign the lost drill pipe <strong>and</strong> then. while being lowered, guide the<br />

tap into the drill pipe to cunlpkte both operations in tine run ot‘ tools into<br />

the hole. This method is particularly desirable when the drill pipe ttm& to fall<br />

over against the wall of a much Larger hole rather than remain erect.<br />

(1) &chken wire Ike: Wheli the<br />

drilling line or s<strong>and</strong> line of ;i cable-<br />

tool drilling rig breaks, leaving the<br />

drilling tools or bailer in the hole<br />

with a substantial amount of wire<br />

line on top of the t00is, the wire<br />

live cerrter spew ( Fig. 5.4.5 ) is the<br />

recommended fishing tool. This tool<br />

consists of a single prong with a<br />

number of upturned spikes project-<br />

ing from it. <strong>The</strong> spikes have sharp<br />

inside corners that permit the spear<br />

to catch even a single str<strong>and</strong> of wire.<br />

If the lost tools are stuck in the<br />

ide md cltnrwt be pulled, the sharp<br />

spikes will shear the win! line.<br />

<strong>The</strong> shoulder of the spear should<br />

be about the same sire as the bore-<br />

!lole in order to prevent the broken<br />

wiie line from getting past the spear<br />

as it is lowered <strong>and</strong> causing it to bc-<br />

come stuck in the hole. Far the<br />

range of boreholc sizes being con-<br />

sidered, center spears are tnade for<br />

specific siLes of hole.<br />

<strong>The</strong> spear is used with a set of<br />

fishing jars. short sinker <strong>and</strong> wire<br />

line socket above it. It should be<br />

carefully eased down the Me to the<br />

point where it is expected to cngagc<br />

the broken cable. It is then pulled<br />

to see if it has a hitch. In the ab-<br />

sence of a hitch it is lowered below<br />

t!le first point <strong>and</strong> again tested f


If the hold is secure, continue<br />

lifting the tools out of the hole until<br />

the broken wiresappear. Stop lifting<br />

<strong>and</strong> tie the wires together <strong>and</strong> then<br />

to the prongs of the grab to prevent<br />

the loose ends from unfolding <strong>and</strong><br />

causing the hold to break. <strong>The</strong> tie<br />

itself does not carry the load but<br />

holds the broken lines in position.<br />

Continue lifting until the lost tools<br />

are recovered.<br />

If the string of lost tools is not<br />

free, then sufficient line should be<br />

let out to bring the jars into use.<br />

Jarring should be continued until<br />

the lost tools come loose or the<br />

broken cable parts.<br />

(3) Fishing for the neck of a<br />

rope<br />

object<br />

socket, 0 t her cy Iindrical<br />

or the pin of a tool: <strong>The</strong><br />

combination socket (Fig. 5.46) is<br />

one of several tools used to catch<br />

the neck of a wire-line socket after<br />

broken line has been cleared away,<br />

or the pin of a bit or drill stem that<br />

has become unscrewed in the hole.<br />

<strong>The</strong> tool can also be used to fish for<br />

any cyhndrical object such as a drill<br />

stem or tubing st<strong>and</strong>ing upright in<br />

the hole, providing the bore of the<br />

socket is at least l/8 inch larger<br />

than the diameter of the fish. <strong>The</strong><br />

fishing string should consist of a<br />

rope socket, stem, long-stroke<br />

fishing jars <strong>and</strong> combination socket.<br />

Combination sockets are pro<br />

vided with two sets of slips, one set<br />

of which is used to engage the<br />

threads of the pin on a bit, stem or<br />

other tool <strong>and</strong> the second set to<br />

take hold of the neck of the rope<br />

socket. <strong>The</strong> proper set of slips must<br />

be selected for the particular fishing<br />

Fig. 5.45 CENTER SPEAR.<br />

job in accordance with knowledge of<br />

the exact size of the fish. It is also<br />

good practice to determine if the socket can go over the fish by first running<br />

the socket with its inner parts removed. <strong>The</strong> re-loaded combination socket is<br />

93


then slowly iowered on the fishing string with the fishing jars adjusted for<br />

shortest stroke. Upon contact with the-fish. a light downward jar is used to<br />

secure a hitch. Tension is then taken on the line <strong>and</strong> the fishing job completed<br />

if the tools are not stuck.<br />

If the tools are stuck, then a slow spudding action should first be tried to<br />

release them. Should this fail. then sufficient line is let out to bring the jars ill-<br />

to use. Short <strong>and</strong> rapid jarring should cause the freeing of the tools <strong>and</strong> is pre-<br />

ferabie to hard long-stroke jarring even ihoaug!~ several hours of work my be<br />

necessary-. Long-stroke jarring could result in break.ing of the hitch on the lost<br />

tools or in broken fishing tools. Alternate up-jarring <strong>and</strong> down-jarring would<br />

release the hitch on the lost tools, should it become obvious that they cannot<br />

be freed <strong>and</strong> recovered.<br />

After successful completion of a fishing job. the hitch is broken by remov-<br />

ing the wooden block above the spring in the combination socket <strong>and</strong> so re-<br />

lieving the pressure on the spring <strong>and</strong> slips.<br />

(4) Releasijrg locked jars: Jars sometimes becorxe stuck or tools above the<br />

jars wedged in the hole by a piece of rock or other material. A jar bumper (Fig.<br />

5.47) is the tool normally used under such circumstances. <strong>The</strong> following pro-<br />

cedure should be followed. A strain is first taken on the drilling cable. <strong>The</strong> jar<br />

bumper is then lowered on the s<strong>and</strong> line, using the drilling cable as a guide,<br />

until the bumper reaches the string of tools. <strong>The</strong> bumper is then raised IO or<br />

12 feet <strong>and</strong> dropped. repeating this as often as necessary to loosen the jars or<br />

string of tools. A few blows are usually sufficient for this purpose. Too many<br />

blows might batter the neck of the rope socket <strong>and</strong> should be avoided. Should<br />

the bumper fail to release the tools, cut the cable <strong>and</strong> use a combination<br />

socket.<br />

95


CHAPTER 6<br />

WE11 C6MPLETION<br />

<strong>Well</strong> completion is the term u\ed to describe the two basic processes which<br />

are undertaken after a well has been constructed in order to ensure a good<br />

yield of water that is clear <strong>and</strong> relatively free of suspended matter <strong>and</strong> dis-<br />

ease-producing organisms. <strong>The</strong>se processes are called well development <strong>and</strong><br />

well disinfection.<br />

WELLDEVELOPMENT<br />

<strong>The</strong> object of well development is the removal of silt, fine s<strong>and</strong> <strong>and</strong> other<br />

such materials from a zone immediately around the well screen, thereby<br />

creating larger passages in the formation through which water can tlow more<br />

freely towards the well.<br />

In addition to the above, well development produces two other beneficial<br />

results. Firstly, it corrects any clogging or compacting of the water-bearing<br />

formation which has occurred during drilling. Clogging is particularly evident<br />

in wells drilled by the, rotary method where the drilling mud effectively seals<br />

the face of the borehole. Driving casing in the cable-tool percussion method<br />

vibrates the unconsolidated particles, thus compacting them. <strong>The</strong>se are not<br />

the only drilling methods that damage the formation in one way or the other.<br />

All drilling methods do to different degrees of magnitude, <strong>and</strong> well develop-<br />

ment is needed to correct this damage.<br />

Secondly, well development grades the material in the water-bearing for-<br />

mation immediately around the screen in such a way that a stable condition<br />

in which the welt yields s<strong>and</strong>-free water at maximum capacity is achieved. In<br />

a zone just outside the screen, ail particles smaller than tl-:e size of the screen<br />

openings are removed by development, thus leaving only ihe coarsest material<br />

in place. A little farther away some medium-sized grains remain mixed with<br />

the coarser ones. This grading of coarse through successively less coarse ma-<br />

terial continues as distance from the screen increases until material of the<br />

original character of the water-bearing formation is reached. This marks the<br />

end of the developed zone around the well. <strong>The</strong> succession of graded zones of<br />

material around the screen stabilizes the formstion so that no further s<strong>and</strong><br />

movement will take place. Tlie extent of the envelope depends upon the<br />

formation characteristics, the well screen design <strong>and</strong> the skill of the well<br />

driller. Fig. 6.1 illustrates the principle of well development described above<br />

<strong>and</strong> which applies to naturally developed wells. Gravel-packed wells present a<br />

somewhat different problem which is discussed later in the chapter.<br />

96<br />

4


Fig.6.t HIGHLY YEIEMEABLE DEVELOPED ZONE AROUND WELL SCREEN.<br />

ALL !~IATERL(AL I-1kk.K IHAN Ikit SCKttN Wk’tl\rlNbS HAS BLkl\r<br />

REMOVED. REMAINING MATERiAL GRADED FROM COARSER TO<br />

FINER SIZES WITH DISTANCE FROM THE SCREEN.<br />

<strong>The</strong> development operation, to be effective. must cause reversais ot‘ tlow<br />

t!trough the screen openings <strong>and</strong> the furmatiun immediately around the well<br />

(Fig. 6.2). This is necessary to rtvuid the bridgirig of openings by groups of


‘N<br />

E<br />

L<br />

VI<br />

E<br />

L


A solid-fj*pe surge plwger is shown in Fig. 0.4. it is of simple WIIstrut<br />

ion. consisting ut‘ two Icather<br />

or rubber-belt discs s<strong>and</strong>wiched between<br />

wooden discs. all assembled<br />

3ver ;L pipe nipple with steel plates<br />

selxing ;IS washers under the end<br />

couplings. <strong>The</strong> leather or rubber<br />

discs shuuld fc)rm :J reasc,nubly<br />

close fit in the well casing. This is<br />

by no means the only way of<br />

making ;t s4id-type surge plunger.<br />

It is only one of several ways of so<br />

doing but serves to illustrate the<br />

essential features of this tool. Vuristions<br />

could include the use of<br />

cupped leather or rubber fazing on<br />

the wooden discs instead of the flat<br />

leuther or rubber-belt discs. A<br />

simple form of plunger can also be<br />

made for use in small diameter<br />

fW”l]< . . . . b;, -. securely tying enough<br />

Fig.6.4 TYPICAL SOLID-TYPE<br />

SURGE PLUNGER.<br />

strips of sacking around the drill<br />

pipe (preferably at ;I joint) to ob-<br />

tain ;1 close fit in the well casing.<br />

Before surging. the weI1 should bc washed with ;I jet of water <strong>and</strong> bailed or<br />

pumped to remove some of the mud cake w the face of the borehoic <strong>and</strong> any<br />

s<strong>and</strong> that may have settled in the screen. This ensures that ;I sufficiently free<br />

flow of water will take place from the aquifer into the well to permit the<br />

plunger to run smoothly <strong>and</strong> freely. <strong>The</strong> surge plunger is then lowered into<br />

the well (Fig. (3.5) to 3 depth It) tu I4 feet under the water but zbuve the top<br />

of the screen. A spudding motion is then applied. repeatedly raising <strong>and</strong><br />

dropping the plunger through ;I distance of 2 to 3 feet. If ;t cable-tool drilling<br />

rig is used. it should be oper:,ted on tk Ion, (I-stroke spudding motion. It is<br />

important that enough weight bc at txhcd to the surge plunger to make it<br />

drop readily on the downstroke . A drill stem or hc~y string of pipe is usu;~IIy<br />

found adequate for this purpose.<br />

Surging should be started s!owly. gradually increasing the s,eed but<br />

keeping within the limit at which the plunger will rise <strong>and</strong> fill smoothly.<br />

Surge for several minutes. noting the speed. stroke <strong>and</strong> time for this initial<br />

operation. Withdraw the plunger. lower the bailer or s<strong>and</strong> pump into the well<br />

<strong>and</strong> after checking the depth of s<strong>and</strong> xxumulatcd in the screen. bail the s<strong>and</strong><br />

out. Repeat the surging operation. compxin, u the quantity of s<strong>and</strong> with that<br />

hr,\,.nirt<br />

v.\tui;l., in ini:ial!y. Bail W: the s<strong>and</strong> <strong>and</strong> repeat the surging <strong>and</strong> bdiling<br />

operaitons until little or IIU s<strong>and</strong> is pulled into the well. <strong>The</strong> time should be<br />

increased for each successive period of surging as the rate of entry ~)t‘ s<strong>and</strong><br />

into the well decreases. <strong>The</strong> s<strong>and</strong>-pump typt‘ of bailer dcscribcd earlier in Chapter<br />

5 is generally Pdvored fix rt‘movin, ~1 s<strong>and</strong> _ during dcvrtopment work.


Static water :evel<br />

-m----.-e<br />

Solid surge plunger<br />

+- <strong>Well</strong> casing<br />

+- <strong>Well</strong> screen<br />

- S<strong>and</strong> <strong>and</strong> silt<br />

in water<br />

Fig. 6.5 SOLID-TYPE SURGE PLUNG<br />

ER READY FOR USE IN DE-<br />

VELOPING A -gELi.. D&X<br />

STROKE FORCES WATER<br />

OUTWARD INTO SAND FOR-<br />

MATION. UPSTROKE PULLS<br />

IN WATER, SILT AND FINE<br />

SAND THROUGH SCREEN.<br />

100<br />

T he valve-type surge phryer<br />

differs from the solid-type surge<br />

plunger in that the former carries 2<br />

number of small portholes through<br />

the plunger which are covered by<br />

soft valve leather. In Fig. 6.6 the<br />

valve leather is raised to indicate<br />

one of the six portholes which are<br />

spaced at equal distances around<br />

the circumference of the plunger.<br />

Valve-type surge plungers are op<br />

erated in a similar manner to solid<br />

plungers. <strong>The</strong>y pull water frum the<br />

aquifer ;,lto the well on the up-<br />

stroke <strong>and</strong>, by allowing some of the<br />

water in the well to press upward<br />

through the valves on the down-<br />

stroke. produce a smaller reverse<br />

flow in the aquifer. This creation of<br />

a greater in-rush of water to the<br />

well than out-rush during the<br />

surging operation is the principal<br />

<strong>and</strong> most important feature of this<br />

type of plunger. <strong>The</strong> valve-type<br />

surge plunger. because of this fea-<br />

ture, is particularly suited to use in<br />

developing wells in formations with<br />

low permeabilities, since it ensures<br />

a net flow of water into the well<br />

rather than out of it. A net outward<br />

flow can result in the water moving<br />

upwards to wash around the out-<br />

side of the casing since the low<br />

permeability of the aquifer will not<br />

permit flow read.ily into it. Washing<br />

around the outside of the casing<br />

could cause caving of the upper<br />

formations <strong>and</strong> thus create very dif-<br />

ficult problems.<br />

An incidental benefit gained<br />

from the use of this type of plunger<br />

is the accumulation of water above<br />

the plunger ;;:ith the eventual dis-<br />

charge of some water, silt <strong>and</strong> s<strong>and</strong><br />

over the top of the well. <strong>The</strong> valves<br />

in effect produce a sort of pumping<br />

action in addition to the surging of


the well <strong>and</strong> thus reduce the<br />

number of times it is necessary to<br />

remove the plunger to bail s<strong>and</strong> out<br />

of the well.<br />

Surge plungers can also be op<br />

erated within the screen. This may<br />

be desirable in developing wells with<br />

long screens. By operating the phmger<br />

within the screen, the surging<br />

action can be concentrated at chosen<br />

levels until the well is fully developed<br />

throughout the entire length<br />

of the screen. <strong>The</strong> surge plungers<br />

should. for iuch use, be sized to pass<br />

freely through the screen <strong>and</strong> its<br />

Fig. 6.6 TYPICAL ?!!!z!~-T~!$<br />

SURGE PL! JNtiEK WIIH<br />

VALVE LEATHER RAISED<br />

TO SHOW ONE OF SIX PORT-<br />

HOLES.<br />

fittings <strong>and</strong> not form a close fit in<br />

them, as is the case when operating<br />

within the well casing. Special care<br />

must be exercised when surging<br />

within the screen to prevent the<br />

plunger from becoming s<strong>and</strong>-locked<br />

by the settling of s<strong>and</strong> above it. For<br />

this reason the use of plungers within<br />

experienced drillers.<br />

screens should only be attempted by<br />

Care must also be exercised when using surge plungers to develop wells in<br />

aquifers containing many clay streaks or clay balls. <strong>The</strong> action of the plunger<br />

can, under such conditions, cause the clay to plaster over the screen surface<br />

with a consequent reduction rather than increase in yield. In addition, surging<br />

of the part]y or wholly plugged screen can produce high differential<br />

with a resulting collapse of the screen.<br />

pressures,<br />

Backwashing<br />

Hjg~-ve/~city jetting or the backwashing of an aquifer with high velocity<br />

jets of water directed horizontally through the screen openings is generally<br />

the most effective method of well development. <strong>The</strong> principal items of equipment<br />

required are a simple jetting tool . a high pressure pump, the necessary<br />

hose, piping, swivel <strong>and</strong> water tank or other source of water supply.<br />

A simple form ofjetting tool for use in small Web is shown in Fig. 6.7, An<br />

appropriately sized coupling with a steel plate welded over one end is screwed<br />

to a I-, l-1/2- or 2-inch pipe. Two to four 3/ 16- or l/4-inch diameter holes,<br />

equally spaced around the circumference are drilled through the full thicknesses<br />

of the coupling <strong>and</strong> the jetting pipe at a fixed distance along the<br />

coupling<br />

i,;iir:,lp~ -c.,---from<br />

the near surface of the steel plate. Better results would be<br />

_- $I ‘~ nn,LJerl-b~ ‘ + =ixy- -‘---gd nozzles are used instep,’ + .’ .I_*.: ‘.I::...:<br />

* “. l ..W “.Laih.,L u.v,ru<br />

ho& shown but the latter are acceptably effective. Any of the above mentioned<br />

sizes -would be suitable for use in a 4-inch well but the 2-inch or<br />

T-T/2$rch tooi would be preferable. <strong>The</strong> I-l/Zinch tool can also be used in a<br />

3~mch web while the l-inch tool is recommended for use in a 2-inch well.<br />

101


<strong>The</strong> procedure is to lower the tool on the jetting pipe to a poini near the<br />

botrom of the screen. <strong>The</strong> upper end of the pipe is c’onnt’cttxl through a<br />

swivel <strong>and</strong> host to the dis&ttrge end of a high prtxure pump such 2s the mud<br />

pump used for hydrtmlic rotary drilling. <strong>The</strong> pump should hc capable of<br />

opsratin~ at 3 pressure of at least IW pounds per squart‘ inch (psi) <strong>and</strong><br />

preferably at about 150 psi while delivering II) to 12 gallons per minute<br />

(gpm) for each Z/ 1 h-inch nozr.te or lh tu 20 gpm for each I /it-inch nuzzle on<br />

the tool. For example. :L tool with two .S/ I Gnch diamttter nozzles would<br />

require a pumping rate of about 20 to 24 gprn. while ;i tr;ol with three<br />

l/4-inch diameter nozzles would require ;i pumping rate of 4X to hO gpm.<br />

While pumpin, u water through the nozzles <strong>and</strong> screen into the formation, t hc<br />

jetting tiara is slowly rotttted. thus washing ;mcl developing the formation near<br />

the bottum of the well screen. <strong>The</strong> jet tin, 0 tool is then raised at intervals of a<br />

few inches <strong>and</strong> the process repeated ur?til the entire length of screen has been<br />

backwashed <strong>and</strong> fully developed.<br />

Where possible. it is very desirable to pump the well at the same time as<br />

the jetting operation is in progress. This may be done in a 4-inch well if ;I<br />

/<br />

Jetting pipe<br />

Coupling<br />

sja!i” or IA”<br />

holes<br />

. Steel plate,<br />

welded to<br />

coupling<br />

i-g* 6:7 SIMPLE TOOL FOR DEVEL-<br />

OPING WELL BY HICH-<br />

VELOCITY JETTING METH-<br />

I-I/_‘-inch jetting pipe is used. thus<br />

permitting 9 small suet ion pipe to<br />

be lowered alc:ng side of it in the<br />

well. <strong>The</strong> static water level must bc<br />

near enough :o the surface to per-<br />

mit pumping by suction lift. By<br />

pumping more water out ~1‘ the<br />

well than is added by jetting. flow<br />

will bt induced into the well from<br />

the aquifer, thus bringing the for-<br />

marion material. loosened by the<br />

jetting, into the well <strong>and</strong> out of it<br />

with the discharged water. This<br />

speeds up the development process<br />

<strong>and</strong> makes it more efficient.<br />

<strong>The</strong> high-velocity jetting method<br />

is more effective in wells con-<br />

structcd with continuous-slol type<br />

well screens. <strong>The</strong> greater percentage<br />

of open area of tl;is type of screen<br />

permits a more effective use of the<br />

energy of the jet in disturbing <strong>and</strong><br />

loosening formation material rather<br />

than in being dissipated by merely<br />

impinging upon the solid areas of<br />

slotted pipe (Fig. 6.X).<br />

Jetting is the inoFt cl‘l‘t&ive of<br />

development methods because the<br />

energy of the jets is concentrated<br />

over small areas at any particular


Fig.6.8 GREATER PERCENTAGE OF OPEN AREA IN CONTINUOUS-SLOT<br />

SCREENS PERMIT3 BETTER DEVELOPMENT BY HIGH-VELOCITY JET-<br />

TING THAN IS POSSIBLE WITH SLO’ITED PIPE.<br />

time <strong>and</strong> every part of the screen can be selectively treated. Thus uniform <strong>and</strong><br />

complete development is achieved throughout the length of the screen. <strong>The</strong><br />

method is also relatively simple to apply <strong>and</strong> not too likely to cause trouble<br />

as a result of over-application.<br />

Another backwashing method ojf deveiopment suitable for use in small<br />

wells is one which uses a centrifugal pump with the suction hose connected<br />

directly to the top of the well casing <strong>and</strong> carrying a gate valve on the dis-<br />

charge end. <strong>The</strong> procedure simply involves the periodic opening <strong>and</strong> closing<br />

of the discharge valve while the pump is in operation. This creates a surging<br />

effect on the well. <strong>The</strong> process is continued until the discharge is clear <strong>and</strong><br />

s<strong>and</strong>-free. <strong>The</strong> method is only applicable where static water levels are such as<br />

to permit pumping by suction lift. Some damage can be caused to the pump<br />

through the wearing of its parts by the s<strong>and</strong> pumped through it. particularly<br />

if in large quantities. <strong>The</strong> use of the pump to be pe:manently installed at the<br />

well is, therefore, not recommended for use in development of a well by this<br />

method.<br />

Development of Gravel-Packed <strong>Well</strong>s<br />

Development of gravel-packed wells is aimed at removing the thin skin of<br />

relatively impervious material which is plastered on the wall of the hole <strong>and</strong><br />

s<strong>and</strong>wiched between the natural water-bearing formation <strong>and</strong> the artificially<br />

placed gravel.<br />

<strong>The</strong> presence of the gravel envelope creates some difficulty in accom-<br />

plishing the job. Success depends upon the grading of the gravel, the method<br />

of development <strong>and</strong> the avoidance of an excess thickness of gravel pack. <strong>The</strong><br />

jetting method, because of its concentration of energy over smaller areas, is<br />

usually more effective than the other methods in developing gravel-packed<br />

I03


wells. <strong>The</strong> thinner the gratlel pack, the more likely is the removal of all of the<br />

undesirable material, including any fine s<strong>and</strong> <strong>and</strong> silt. <strong>The</strong> use of dispersing<br />

agents (described immediately below) such as polyphosphates effectively<br />

assist in loosening sift <strong>and</strong> clay.<br />

Dispersing Agents<br />

Dispersing agents, mainly polyphosphates, are added to the drilling fluid,<br />

backwashing or jetting water, or water st<strong>and</strong>ing in the well to counteract the<br />

tendency of mud to stick to s<strong>and</strong> grams. <strong>The</strong>se agents act by destroying the<br />

gel-like properties of the drilling mud <strong>and</strong> dispersing the clay particles, thus<br />

making their removal easier. Sodium hexametaphosphate is probably the best<br />

known of these chemical agents. though tetra sodium pyrophosphate, sodium<br />

tripolyphosphate <strong>and</strong> sodium septaphosphate are also effectively used in<br />

well development. <strong>The</strong>se agents work effectively when applied at the rate of<br />

half a pound of the chemical to every LOO gallons of water in the well. <strong>The</strong><br />

mixture should be allowed to st<strong>and</strong> for about one hour before starting devel-<br />

opment operations.<br />

WELL DISINFEC-HON<br />

Disinfection is the fmal step in the completion of a well. Its aim is the<br />

destruction of ah disease-producing organisms introduced into the well during<br />

the variotis construction operations. Entry of these organisms into the well<br />

can occur through contaminated drilling water, on equipment, materials or<br />

through surface drainage into the well. All newly constructed wells with the<br />

possible exception uf flowing artesian wells should. therefore, be disinfected.<br />

WeIls should also be disinfected after repair <strong>and</strong> before being returned to use.<br />

<strong>The</strong> water from flowing artesian wells is generally free from contamination by<br />

disease-producing organisms after being allowed to flow to waste for a short<br />

while. If. however, analyses show persistent contamination, then the well<br />

should be disinfected as described later in this chapter.<br />

Because of the problems of testmb for specific disease-producing orga-<br />

nisms, of which there may be several types present in water, coliform bacteria<br />

are used as indicators of the possible presence of disease-producing organisms<br />

of human or animal origin in water. Disinfection is, therefore, considered<br />

complete when sampling :tnd testing of water show the presence of no<br />

coliform bacteria. Sampling <strong>and</strong> testing should be undertaken by experienced<br />

personnel from a health agency or recognized laboratory.<br />

<strong>The</strong> well should be cleaned. as thoroughly as possible, of foreign sub-<br />

stances such as soil, grease <strong>and</strong> oi! before disinfection. Disinfection is most<br />

conveniently achieved by the addition of a strong solution of chlorine to the<br />

well. <strong>The</strong> contents of the weLl should then be thoroughly agitated <strong>and</strong> al-<br />

lowed to st<strong>and</strong> for several hours <strong>and</strong> preferably overnight. Care should also be<br />

taken io wash all surfaces above the water level in the well with the disin-<br />

fecting solution. Foliowing this. the well zhould be pumped icrtg enough to<br />

change its contents several times <strong>and</strong> so flush the excess chlorine out of it.<br />

Calcium hypochlorite is the most popular source of chlorine used in the<br />

disinfection of wells. It is sold in chemical supply <strong>and</strong> some hardware stores<br />

in the granular <strong>and</strong> tablet form containing 70 percent of available chlorine by<br />

104


weight. It is fairiy siable when dry, retaining 90 percent of its original<br />

chlorine content after one year’s storage. When moist, it loses its strength <strong>and</strong><br />

becomes quite corrosive. It should, therefore, be stored under cool, dry con-<br />

ditions. Enough calcium hypochlorite should be added to the water st<strong>and</strong>ing<br />

in the well to produce a solution of strength ranging from 50 to 200 parts per<br />

million (ppmj by weight <strong>and</strong> usually about 100 ppm. A solution of approx-<br />

imately 100 ppm chlorine can bc obtained by adding 2 ounces or 4 heaped<br />

tablespoons of calcium hypochlorite (containing 70 percent of available<br />

chlorine) to every 100 gallons of water st<strong>and</strong>ing in the well. Usually for<br />

convenience of application, a stock solution is made by mixing the caicium<br />

hypochlorite with a small amount of water to form a smooth paste <strong>and</strong> then<br />

adding the remainder of 2 quarts of water for every ounce of the chemical.<br />

Stir the mixture thoroughly for 10 to 15 minutes before allowing to settle.<br />

<strong>The</strong> clearer liquid is then poured off for use in the well. A gallon of this<br />

solution. when added to 100 gallons of water in the well, produces a solution<br />

of strength approximately equal to 100 ppm of chlorine. <strong>The</strong> stock solution<br />

should be prepared i!~ a thoroughly cleaned glass, crockery or rubber lined<br />

container. Metd containers become corroded <strong>and</strong> should be avoided. Stock<br />

solutions should be prepared to meet immediate needs only since they lose<br />

strength rapidly unless properly stored in tightly covered dark glass or plastic<br />

containers. Storage of the chemical in the dry form is much more desirable.<br />

Sodium hypochlorite may be used in the absence of calcium hypochlorite.<br />

This chemical is available only in liquid form <strong>and</strong> can be bought in strengths<br />

of up to about 20 percent available chlorine. In its most common form,<br />

household laundry bleach, it has a stJ-c?ngth of about 5 percent of available<br />

chlorine. A stock solution of equivalent strengh to that made from calcium<br />

hypochlorite <strong>and</strong> described in the previous paragraph can be made by dilcting<br />

commercial bleach with twice as much water. This stock solution should also<br />

be added to the well at the rate of one gallon to every 100 gallons of water in<br />

the well.<br />

Flowing artesian wells are disinfected, when necc;zT, hy !cJwering a per-<br />

forated container, such as a short length of tubing capped at both ends, Zlzi?<br />

with an adequate quantity of dry calcium hypochlorite to the bottom of the<br />

well. <strong>The</strong> natural up flow of water in the well will distribute the dissolved<br />

chlorine throughout the full depth of the well. A stuf’ig box can be used at<br />

the top of the well to partially or completely restrict the flow <strong>and</strong> so reduce<br />

the chiorine losses.<br />

105


<strong>Well</strong>s, like all other engineering structures. need regular, routine main-<br />

tenance in the interest of a continuous high level of performance <strong>and</strong> a<br />

maximum useful life. <strong>The</strong> general tendency towards the maintenance of wells<br />

is one that can best be described as “out of sight - out of mind.” Con-<br />

sequently, very little or no attention is paid to wells after completion until<br />

problems reach crisis levels, often resulting in the complete loss of the well.<br />

<strong>The</strong> importance of a routine maintenance program to the prevention, early<br />

detection <strong>and</strong> correction of problems that reduce well performance <strong>and</strong> use-<br />

ful life cannot be overemphasized. A routine maintenance program can pay<br />

h<strong>and</strong>some dividends to a well owner <strong>and</strong> will certainly result in long-term<br />

benefits that exceed its cost of implementation.<br />

FACTORS AFFECTING THE MAINTENANCE OF WELL PERFORMANCE<br />

<strong>The</strong> factors affecting the maintenance of well performance or yield are<br />

numerous. Care should be taken to differentiate between those factors asso-<br />

ciated with the normal wearing of pump parts <strong>and</strong> those directly associated<br />

with changing conditions in <strong>and</strong> around the well. A perfectly functioning<br />

well, for example, can show a reduced yield because of a reduction in the<br />

capacity of the pump due to excessively worn parts. On the other h<strong>and</strong>, the<br />

excessive wearing of pump parts may be due to the pumping of s<strong>and</strong> entering<br />

the weII through a corroded weli screen. It is also possible for corrosion to<br />

affect only the pump, reducing its capacity, but to have little or no effect on<br />

a properly designed well.<br />

<strong>The</strong> hydrologic conditions of some aquifers are such that the static water<br />

level drops graduaIly when. wells are pumped continuously. While this results<br />

in reduced yields unless pumping levels are also correspondingly lowered, it is<br />

not an indication of a failure of the well itself, necessitating repairs or treat-<br />

ment of any forin.<br />

Most commonIy, a decrease in the capacity of a well results from the<br />

clogging of the well screen openings <strong>and</strong> the water-bearing formation imme-<br />

diately xound the well screen by incrusting deposits. <strong>The</strong>se incrusting depos-<br />

its (Fig. 7.1) may be of the hard cement-like form typical of the carbonates<br />

<strong>and</strong> sulfates of calcium <strong>and</strong> magnesium, the soft sludge-like forms of the iron<br />

<strong>and</strong> manganese hydroxides or the geIatinous slimes of iron bacteria. Iron may<br />

also be deposited in the form of ferric oxide with a reddish-brown, scale-like<br />

appearance. Less common is the deposition of soil materials such as silt <strong>and</strong><br />

cIay.<br />

106


A B C<br />

Fig. 7.1 FORMS OF INCRUSTATION.<br />

__ L<br />

A. Hard cement-like deposits of calcium <strong>and</strong> magnesium carbonates.<br />

B. Gelatinous slime deposits typical of iron b~t4~<br />

C. Scale-like deposits of iron oxide completely plugging screen openings.<br />

<strong>The</strong> deposition ot ctlrbomrtes <strong>and</strong> the compounds of iron <strong>and</strong> munganese<br />

can often be traced to the release of carbon dioxide from the water. <strong>The</strong><br />

capacity of water to frofd carbon dioxide varies directly with the pressure<br />

the higher the pressure. the greater tfre quantity of carbon dioxide fleld.<br />

Pumping of a we11 reduces the pressure in <strong>and</strong> near the well. thus allowing the<br />

escape of carbon dioxide to the atmosphere <strong>and</strong> altering tire chemical quality<br />

of the water in such ;t manner as to cause the precipitation of carbonate <strong>and</strong><br />

iron deposits.<br />

A change in velocity is another factor that can result in the precipitation<br />

of iron <strong>and</strong> manganese hydroxides. This too occurs at 2nd near the well<br />

screen where the velocity of the slowly flowing water is suddenly increased<br />

on entry to the well.<br />

PLANNING<br />

<strong>The</strong> pianning of well maintenance procedures should be based on a system<br />

of good record keeping. <strong>The</strong> preceding paragraphs have indicated that the<br />

problems that result in reduced well yields occur at <strong>and</strong> around the well<br />

screen <strong>and</strong> very much out of sight. <strong>The</strong> analysis of good records must, therefore,<br />

be relied upon as the source of problem detection in weflc. <strong>The</strong>re can be<br />

no substitute for the keeping of good records.<br />

Among the records kept sfroufd be pumping rates. drawdown. total hours<br />

-_-._<br />

d opcrztion, puwt~r consumption <strong>and</strong> water quafity analyses. Pumping rates<br />

<strong>and</strong> drawdown are particularly useful in determining the specific capacity (discharge<br />

per foot of drawdown) which is the best indicator of existing problems<br />

in a well. <strong>The</strong> specific capacities of wells should be checked periodically <strong>and</strong><br />

compared with previous values including those immediately after completion<br />

107


of the wells to determine whether significant reductions have taken place. A<br />

significant reduction in the specific capacity of a well could often be traced to<br />

blockage of the well screen <strong>and</strong> the formation around it, most likely by<br />

incrusting deposits. As stated earlier. a reduction in the pump discharge<br />

would not by itself be evidence of a reduced capacity of the well. If, however,<br />

the drawdown in the well does not show an equal reduction, then the specific<br />

capacity will be reduced, thus indicating the probability of an incrustation<br />

problem.<br />

Power consumption records also provide valuable evidence of the existence<br />

of problems in wells. Should there be an increase in power consumption, not<br />

accompanied by a corresponding increase in the quantity of water pumped,<br />

then a problem is possible in either the pump or the well. Should an mvesti-<br />

gation show no problems in the pump nor appreciable increase in the dynam-<br />

ic head against which the pump has been operating, then it is most likely that<br />

a problem exists in the well <strong>and</strong> that the problem is causing an increased<br />

drawdown. A check on the drawdown should then be undertaken to verify<br />

the deduction <strong>and</strong> the well checked for incrustation.<br />

Since there would be no incrustation in the absence of incrusting chem-<br />

icals in the water. the value of chemical analyses of well water is self-evident.<br />

Such analyses are more useful as problem indicators if undertaken regularly.<br />

<strong>The</strong>y indicate the type of incrustation that might occur <strong>and</strong> the expected rate<br />

of deposition in the well <strong>and</strong> its vicinity. <strong>The</strong> quality of some well waters<br />

changes slowly with time <strong>and</strong> orl!y regular routine analyses would indicate<br />

such changes.<br />

In wells, the waters of which are known to be incrusting, the frequency of<br />

observations of all types should be as high as possible <strong>and</strong> consistent with the<br />

use to which the water is being put. Observations should be made muzh more<br />

frequently at wells serving a community than at a private home-owner’s well,<br />

since more people are dependent on the community wells. Power con-<br />

sumption. well discharge, drawdown, operating hours <strong>and</strong> other such observa-<br />

tions are often made daily on community wells <strong>and</strong> may even be done on a<br />

continuous basis. Chemical analyses on such wells may be done on an annual,<br />

semi-annual or quarterly basis, as conditions warrant them. Observations on<br />

home-owner’s weils are usually much less frequent but should, nevertheless,<br />

be undertaken regularly.<br />

MAINTENANCEOPERATIONS<br />

Maintenance operations should not be deferred until problems assume<br />

major proportions as rehabilitation then becomes more difficult <strong>and</strong> some-<br />

times impossible or impracticable. incrustation not treated early enough can<br />

so clog the well screeri <strong>and</strong> the formation around it that it becomes extremely<br />

difficult <strong>and</strong> even impossible to diffuse a chemical solution to all affected<br />

points in the formation. Any attempts at rehabilitation would then prove<br />

unsuccessful.<br />

No methods have yet tzen developed for the complete prevention of<br />

incrustation in wells. Various steps 2zn be taken to delay the process <strong>and</strong><br />

reduce the magnitude of its effects. Among these are the proper design of


well screens <strong>and</strong> the reduction of pumping rates, both aimed at reducing<br />

entrance velocities into screens <strong>and</strong> drawdown in wells. For example, it may<br />

be worthwhile to share the pumping load among a larger number of wells in<br />

order to reduce the rate of incrustation. Howel:er, the ultimate or fmal solu-<br />

tion will be in a regular cleaning program. incrusting wells are usually treated<br />

with chemicals which either dissolve the incrusting deposits or loosen them<br />

from the surfaces of the well screen <strong>and</strong> formation materials so that the<br />

deposits may be easily removed by bailing.<br />

Acid Treatment<br />

Acid treatment refers to the treatment of a well with an acid, usually<br />

hydrochloric (muriatic) acid or sulfamic acid for the removal of incrusting<br />

deposits. Both of these acids readily dissolve calcium <strong>and</strong> magnesium carbon-<br />

ate, though hydrochloric acid does so at a faster rate. Strong hydrochloric<br />

acid solutions also dissolve iron <strong>and</strong> manganese hydroxides. <strong>The</strong> simultaneous<br />

use of an inhiiitor serves to slow up the tendency of the acid to attack steel<br />

casing.<br />

<strong>Well</strong>s are sometimes treated with acid in preparation for the withdrawal of<br />

a screen either for re-use elsewhere or in the same well. For example, it may<br />

be desirable to recover a screen that is in good condition from a well whose<br />

casing has been corroded beyond usefulness. Or, a screen may be recovered<br />

for more effective treatment against incrustation thBn can be achieved in the<br />

well. In either case, a preliminary acid treatment to dissolve some of the<br />

incrusting deposits will make it much easier to pull the screen.<br />

Hydrochloric acid is usually available in three grades from chemical supply<br />

shops. <strong>The</strong> strongest grade, designated as the 27.92 percent grade, should be<br />

used. It is sold in either glass or plastic carboys containing about 12 gallons<br />

each. If inhibited acid cannot be obtained, unflavored gelatin added at the<br />

rate of 5 to 6 pound? ?o every 100 gallons of acid will prevent serious damage<br />

to steel casing.<br />

Hydrochloric acid should be used at full strength. Each treatment us&&y<br />

requires l-112 to 2 times the volume of water in the screen. This provides<br />

enough acid to fill the screen <strong>and</strong> additional acid to maintain adequate<br />

strength as the chemical reacts with the incrusting materials. Fig. 7.2 illus-<br />

trates a method of placing acid in a well. Acid is introduced within the screen<br />

by means of a wide-mouthed funnel <strong>and</strong> 3/4- or l-inch black iron or plastic<br />

pipe. Acid is heavier than water which it tends to displace but with which it<br />

also mixes readily to become diluted. When used in long screens, acid should<br />

be added in quantities sufficient to fill 5 feet of the screen <strong>and</strong> the conductor<br />

pipe raised 5 feet after pouring each quantity.<br />

<strong>The</strong> acid solution in the well should be agitated by means of a surge<br />

plunger or other suitable means for 1 to 2 hours following which the well<br />

should be bailed until the water is relatively clear. <strong>The</strong> driller usually can<br />

detect an improvement in the yield of the well while running the bailer. <strong>The</strong><br />

well may, however, be pumped to determine the extent of improvement. If<br />

this is not as expected, then the treatment may be repeated using a longer<br />

period of agitation before bailing. A third treatment may even be undertaken.<br />

<strong>The</strong> procedure is sometimes varied to alternate acid treatment <strong>and</strong> chlorine<br />

109


Black iron or plastic<br />

pipe<br />

<strong>Well</strong> screen<br />

Acid placed inslde<br />

well screen<br />

Fig.7.2 ARRANGEMENT FOR<br />

INTRODUCING ACID IN-<br />

SIDE WELL SCREEN FROM<br />

BOTTOM UPWARDS.<br />

treatment (described later in this<br />

chapter,), repeating the alternate<br />

treatments as many times as it<br />

appears that beneficial results are<br />

being obtained. <strong>The</strong> chlorine helps<br />

to remove the slime deposited by<br />

iron bacteria.<br />

Sulj~mk acid can be obtained as<br />

a dry granular material which pro-<br />

duces a strong acid solution when<br />

dissolved in water. It offers a num-<br />

ber of advantages over hydrochloric<br />

acid as a means of treating incrusta-<br />

tion in wells. It can be added to a<br />

well in either its original granular<br />

form or as an acid solution mixed on<br />

site. Granular sulfamic acid is non-<br />

irritating to dry skin <strong>and</strong> its solution<br />

gives off no fumes except when<br />

reacting with incrusting materials.<br />

Spillage, therefore, presents no haz-<br />

ards <strong>and</strong> h<strong>and</strong>ling is easier, cheaper,<br />

<strong>and</strong> safer. It also has a markedly<br />

less corrosive effect on well casing<br />

<strong>and</strong> pumping equipment <strong>and</strong> is safe<br />

for use on Everdur <strong>and</strong> type 304<br />

stainless steel well screens. <strong>The</strong>se<br />

advantages tend to offset its higher<br />

cost than inhibited hydrochloric<br />

acid. Sulfamic acid dissolves calcium<br />

<strong>and</strong> magnesium carbonates to pro-<br />

duce very soluble products. <strong>The</strong><br />

reaction is, however, slower than<br />

that using hydrochloric acid <strong>and</strong> a<br />

somewhat longer contact period<br />

in the well is required.<br />

Sulfamic acid is usually added to<br />

wells in solution form using a black<br />

iron or plastic pipe as described for<br />

the application of hydrochloric acid.<br />

Ten gallons of water dissolve 14 to<br />

20 pounds of the granules depending<br />

upon the temperature of the water.<br />

<strong>The</strong> granular material itself can,<br />

however, be poured into <strong>and</strong> mixed<br />

with the water st<strong>and</strong>ing in the well.<br />

<strong>The</strong> water must be agitated to en-


sure complete solution of the acid. <strong>The</strong> quantity of acid added in this case<br />

should be based on the total volume of-water st<strong>and</strong>ing in the well <strong>and</strong> not on<br />

that in the screen only. as is the case if the acid is applied in solution form. An<br />

excess of the granular material may be added to keep the solution up to<br />

maximum strength while it is being used up through reaction with the tncrust-<br />

mg material. <strong>The</strong> addition of a low-foaming, non-ionic wetting agent im-<br />

proves the cleansing action to some extent.<br />

A number of precatctims must be exercised in using any strong acid solu-<br />

tion. Goggles <strong>and</strong> water-proof gloves should be worn by all persons h<strong>and</strong>ling<br />

the acid. When preparing an acid solution, always pour the acid slowly into<br />

the water. In view of the variety of gases, some of them very to.xic, produced<br />

by the reaction of acid with incrusting materials, adequate ventilation should<br />

be provided in pump houses or other confined spaces around treated wells.<br />

Personnel should not be allowed to st<strong>and</strong> in a pit or depression around the<br />

well during treatment because some of the toxic gases such as hydrogen<br />

sulfide are heavier than air <strong>and</strong> will tend to settle in the lowest areas. ,Zfter a<br />

well has been treated, it should be pumped to waste to ensure the complete<br />

removal of all acid before it is returned to normal service.<br />

Chlorine Treatment<br />

Chlorine treatment of wells has been found more effective tha:: acid treat-<br />

ment in loosening bacterial growths <strong>and</strong> slime deposits which often<br />

accompany the deposition of iron oxide. Because of the very high concen-<br />

trations required. 100 to 200 ppm of available chlorine, the process is often<br />

referred to as shock treatmetrt with chlorine. Calcium or sodium hypochlorite<br />

may be used as the source of cfllorine as described for the disinfection of<br />

wells in Chapter 6. <strong>The</strong> chlorin e soltuion in the well must be agitated. This<br />

may be done by using the high-velocity jetting technique (see “<strong>Well</strong> Develop<br />

ment,” Chapter 6) or by surging with a surge plunger or other suitable<br />

techniques. <strong>The</strong> recirculation provided with the use of the jetting technique<br />

greatly Improves the effectiveness of the treatment.<br />

<strong>The</strong> treatment shotild be repeated 3 or 4 times in order to reach every part<br />

of the formation thet may be affected, <strong>and</strong> it may also be alternated with<br />

acid treatmeni, the latter being performed first.<br />

Dispersing Agents<br />

Polyphosphates, or glassy phosphates as they are commonly called, effec-<br />

tively disperse silts, clays <strong>and</strong> the oxides <strong>and</strong> hydroxides of iron <strong>and</strong> man-<br />

ganese. <strong>The</strong> dispersed materials can be easily removed by pumping. In addi-<br />

tion, the polyphosphates are safe to h<strong>and</strong>le. <strong>The</strong>y find considerable applica-<br />

tion, therefore, in the chemical treatment of wells.<br />

For effective treatment, 15 to 30 pounds of polyphosphate are added lo<br />

every 100 gallons of water in the well. A solution is usually made by SUJ-<br />

pending a wire basket or burlap bag containing the polyphosphate in a tank<br />

of water. Abo,ut a pound of calcium h; pochlorite should be added for every<br />

IOU gallons of water in the well in order to facilitate the removal of iron<br />

bacteria <strong>and</strong> their slimes <strong>and</strong> also for disinfection purposes. After pouring this<br />

polyphosphate <strong>and</strong> Eypochlorite solution into the well, a surge plunger or the


,&ting technique is used to agitate the water in the well. <strong>The</strong> recirculation of<br />

the solution with the use of the high-velocity jetting technique greatly im-<br />

proves the effectiveness of the treatment. Two or more successive treatments<br />

may be used for better results.<br />

WELLPOINTINSTALLATPONINDUGWELLS<br />

Dug wells are holes or pits dug by h<strong>and</strong> or machine tools into the ground<br />

to tap the water table. <strong>The</strong>y are ususclly 3 to 20 feet in diameter, IO to 40<br />

/<br />

Asphaltic seal<br />

Fig. 7.3 DUG WELL. Fig. 7.4 DUG WELL OF FIG. 7.3<br />

CONVERTED TO SAFER<br />

AND MORE PRODUCTIVE<br />

TUBULAR WELL WlTH<br />

DRIVEN WELL POINT AS<br />

SCREEN.<br />

feet deep <strong>and</strong> lined with brick, jiune, tile. wood cribbing or steel rings to pre-<br />

vent the walls from caving (Fig. 7.3). <strong>The</strong>y depend entirely on natural seepage<br />

from the penetrated portion of water-bearing formations for their yield of<br />

water.


This type of well is at a disadvantage on two scores when compared with<br />

tubular wells of the type so far described. Firstly, dug wells are much more<br />

diffcu!t to maintain in a sanitary condition. Secondly, their yields are very<br />

low, because they do not penetrate very far into the water-bearing formation<br />

<strong>and</strong> cannot be developed in a similar manner to screened wells.<br />

Dug wells usually can be made much safer <strong>and</strong> more productive by driving<br />

well points into the water-bearing formation <strong>and</strong> thus converting them into<br />

tubular wells. A properly developed well with a short length of 2” drive-<br />

point screen will usually produce water at 3 much higher rate than can be had<br />

from a dug well several feet in diameter. <strong>The</strong> annular space between the casing<br />

of the driven well <strong>and</strong> the wall of the existing well shouid be back-filled with<br />

a puddled clay or other suitable material. <strong>The</strong> sanitary precautions with re-<br />

spect to the completion of the upper terminal of 3 well (described in Chapter<br />

4) should be observed. <strong>The</strong> wall of the existing dug well may be cemented<br />

prior to back-filling. A converted dug well is illustrated in Fig. 7.4.<br />

113


Drilling <strong>and</strong> completing a well form only part of a solution to the<br />

problem of getting water in sufficient quantity where it is desired for use.<br />

Small wells are generally used for supplying water to a horn&:, a group of<br />

homes or other such limited consumers of water as a small factory. <strong>The</strong> water<br />

is usually required for use at elevations somewhat higher than tkose at which<br />

the water is found in the well <strong>and</strong>, often, some appreciable distance from the<br />

well. <strong>The</strong>refore, some means must be found of lifting the water from a well<br />

<strong>and</strong> forcing it through pipes at suitable velocities to the points <strong>and</strong> elevations<br />

of use. Tfke exception to this general statement is the case of the flowing<br />

artesian well, which has a sufficiently high discharge at an adequate pressure<br />

to meet the limited dem<strong>and</strong>s of one or a few small holmes without any<br />

external help. Generally, however, help is needed, <strong>and</strong> this is provided in the<br />

form of a suitable pump. It is important that the pump be a suitable cjne,<br />

selected on the basis of the dem<strong>and</strong> to be fulfilled <strong>and</strong> the capacity of the<br />

well to yield water. It cannot <strong>and</strong> must not be just any pump, as it is then<br />

unlikely that the needs will be met. Pump selection is discussed later in this<br />

chapter.<br />

Pumps do not develop power of their own. Some ex!ernal source of power<br />

must be provided to drive a pump <strong>and</strong> so cause it to lift <strong>and</strong> force water from<br />

one point to another. <strong>The</strong> source of power may be the man who uses his h<strong>and</strong><br />

to operate 3 lever upward <strong>and</strong> downward or forward <strong>and</strong> backward or who<br />

turns a wheel connected to the pump. In this case, the pump is said to be<br />

manually operated or h<strong>and</strong> driven. <strong>The</strong> power source may also be a windmill,<br />

an electric motor or an engine which burns a fuel such as gasoline or diesel<br />

oil. A very common error is not being able to distinguish between a pump <strong>and</strong><br />

its motive or driving force, particularly when that force is an engine or motor<br />

directly coupled to the pump. Care should be taken to avoid this, 3s the<br />

problems of pumps, engines <strong>and</strong> motors are very different <strong>and</strong> need different<br />

approaches to solve them.<br />

<strong>The</strong> action of most pumps can be divided into two parts. <strong>The</strong> first is the<br />

lifting of the water from some lower level to the pump intake or suction side<br />

of the pump. <strong>The</strong> second is concerned with applying pressure to the water in<br />

the pump to force the water to its destination,<br />

SU&MZ lift: Consider an openended tube which is suspended vertically in<br />

a large container of water (Fig. 8.IA). Since the water both within <strong>and</strong><br />

without the tube is exposed to the atmosphere, the only external force acting<br />

114


Atmospheric<br />

pressure<br />

?-<br />

A<br />

Atmospheric<br />

Zero pressure<br />

(absolute)<br />

Fig. 8.1 A. ATMOSPHERIC PRESSURE THROUGHOUT. NO DIFFERENCE IN<br />

WATER LEVELS.<br />

B. PRESSURE IN TUBE REDUCED TO ZERO ATMOSPHERES (TOTAL<br />

VACUUM). WATER LEVEL W TUBE RISES TO APPROXIMATELY<br />

34 FT.<br />

on both surfaces is that due to atmospheric pressure. <strong>The</strong> pressure on the<br />

water surface being the same within <strong>and</strong> without the tube, there will be no<br />

difference in the water levels (assuming a wide enough tube that capil!ary<br />

forces may be neglected). if, however, the pressure on the water surface<br />

within the tube is reduced below atmospheric pressure while that outside of<br />

the tube remains at atmospheric pressure, then water will rise in the tube<br />

until th,? weight of the column of water inside the tube exerts a pressure<br />

equal to the original pressure difference on the water surfaces within <strong>and</strong><br />

without the tube. <strong>The</strong> maximum height to which this column wilt rise occurs<br />

when the pressure on the water surface within the tube is reduced to zero<br />

atmospheres (absolute). <strong>The</strong> water column will then be exerting a downward<br />

pressure equal to the atmospheric pressure (Fig. 8.1B). Atmospheric pressure<br />

at sea level is approximately equivalent to a column of water 34 feet high,<br />

<strong>and</strong> this is the height to which the water will rise in the tube. Atmospheric<br />

pressure decreases as the altitude or height above sea level increases.<br />

Accordingly, the maximum height to which the water column can be made to<br />

rise also decreases with increase of altitude.<br />

<strong>The</strong> term SUCY~M is used to describe ihc amount by which the pressure in<br />

the tube is reduced below atmospheric pressure. Suction can be applied to the<br />

tube by operating a pump attached to the top end of the tube. <strong>The</strong> level to<br />

which the water rises within the tube above the water surface in the large


container is termed the srrctiorl hji. AL pump. in order to pump water. must be<br />

able to create enough suction to lift the water in the tube to the level of the<br />

suction end of the pump. In Fig. 8.2, t!le well casing represents the larger<br />

container while the suction pipe of the pump takes the place of the tube.<br />

I-<br />

Pump<br />

/ 4 I<br />

Atmospheric w<br />

PI I<br />

./ Wall casing<br />

water bfsl<br />

<strong>Well</strong> screen<br />

Fig.8.2 PRINCIPLES OF PL'MPINC<br />

AWATERWELL.<br />

Note- that the lifting of the water in<br />

the suet ion pipe must be ;ICCOII~-<br />

parlied by ;1 lowering of the water<br />

level in the well casing. <strong>The</strong> water<br />

level within the casing :lild the<br />

suction pipe before the pump<br />

created the suction lift is called the<br />

stuck rryater IwA <strong>The</strong> level in the<br />

well txing during pumping is the<br />

privrpirlg bvater level.<br />

In theory then, a pump, by<br />

creating zero pressure (absolute) or<br />

9 total vacuum within its suction<br />

pipe. should be capable of ;1 suction<br />

lift of ~ppruximately 34 feet of<br />

water at sea level <strong>and</strong> somewhat less<br />

3t higher altitudes. In practice,<br />

however. this is not achieved. as<br />

pumps are not 101) percent efficient.<br />

<strong>and</strong> other fxtors such ;LS<br />

water temperature <strong>and</strong> friction or<br />

resistance to flow in the suction<br />

pipe reduce the suction lift. At sea<br />

level. the best designed pu171ps usually<br />

achieve ;I suction lift of about<br />

-- ‘5 feet. while the suction lift of an<br />

average pump varies from 15 to<br />

about IX feet. Should it be neces-<br />

sary to lift water in ;t well from a<br />

level 25 feet or more below ground<br />

surfxe. some mc;ms must bc found<br />

of lowering the pump into the well<br />

<strong>and</strong> ::ither completely submerging<br />

the pump in the water or taking it<br />

near enough to the water surface to<br />

pertnit suction lifting of the water.<br />

This iimitiq suction lift is used to classify pumps into surface-type or shalPow<br />

well pumps <strong>and</strong> deep well pumps. SurjIzce-type pumps are those pumps which<br />

are placed at or above ground jurfrtce rind are iimited to lifting water by<br />

suction fronl a dzpth . . ..-...II-. -.. .--- l L . .._. . .<br />

uxkmy IIU ;;lvdtCi iihui LL b iiiit 25 fe?i belo’* the ground<br />

surface. Deep \treI! prmps are those pumps which arc placed within the well<br />

<strong>and</strong> are used for extracting<br />

I.elow the ground surface.<br />

water frotn depths generally in L’XWSS of 25 feet


.4nother very common classification of pumps divides them into two main<br />

types based on the mechanical principles involved. <strong>The</strong>se two types are<br />

comtant dispkemertt tend wriable displacemerlt pumps.<br />

CONSTANT DISPLACEMENT PUMPS<br />

Constant displacement pumps are so designed that they deliver substan-<br />

tially the same quantity of water regardless of the pressure head against which<br />

they are operating. That is to say. the rate of discharge is essentially the same<br />

at low or high pressures. However, the input power or driving force varies<br />

directly in proportion to the pressure in the system <strong>and</strong> must be doubled ii<br />

the pressure is doubled. <strong>The</strong>re are three main designs of this type of pump<br />

which are commonly used in water wells. <strong>The</strong>se are reciprocatirlg piston<br />

pumps, rotaop pumps <strong>and</strong> helical rotor pumps.<br />

Reciprocating Piston Pumps<br />

Reciprocating piston pumps, the most common type of constant displace-<br />

mcnt pump. use the up <strong>and</strong> down or forward <strong>and</strong> backward (reciprocating)<br />

movement of a piston or plunger to displace water in a cylinder. <strong>The</strong> flow in<br />

<strong>and</strong> out of the cylinder is controlled by valves. <strong>The</strong> basic principles <strong>and</strong> steps<br />

in the operation of a single-acting piston pump are illustrated in Fig. 8.3. <strong>The</strong><br />

Forward Stroke<br />

Reverse Stroke<br />

Closed<br />

II<br />

Dischargei<br />

‘Open<br />

Forward Stroke<br />

Fig. 8.3 PRlNCIPLES OF A SINGLE-ACTING RECIPROCATING PISTON PUMP.<br />

(Adapted from Fig. 38, <strong>Water</strong> Supply For Rural Areas And Small Communi-<br />

fies, WHO !+Ionograph Series No. 42, 1959.)


plunger on the tijrward stroke p~~shes writer t‘rw~~ the c‘ylittdcr through tllc<br />

open dischye vltlve into the dischxge pipt‘ u tlilc at 111~ suw timt’ crcatins ;I<br />

suction behind it thttr ~~p~nj the foot valw ;md pc’rmits water to tlobv tllrou$1<br />

the suction pipe into the cylinder. ‘l‘hc ~‘t’vt’rst St:-ohc ctwtes ;I prcssurt2<br />

behind the piston in the cylinder. thus chin, 11 the foot valve <strong>and</strong> opcnilig the<br />

bucket vrtlves in the piston tu let water through to ttlt‘ discharge side ot‘ tllc<br />

piston. Continuous repetition of the for\i,xd <strong>and</strong> rcvc’lsc strokes of the piston<br />

results in 9 steady tlow at watt‘r out of the dishargc pipe. ‘fhc amount 01’<br />

pressure developed by such ;t pump depetlds upw the power applied in<br />

operating the piston. Tht~se pumps art‘ manufxtured irl both the surt’vce (Fig.<br />

S-4) <strong>and</strong> deep well (Fig. S.5) typ t‘s <strong>and</strong> may be manually or enpinc operated.<br />

.4 m;~nutllly operated.<br />

pitcher pump.<br />

surP>c+type piston pump is c~~rnnnc~nly known ;1s ;I<br />

Fig. 8.5 DEEP WELL SINGLE-ACT-<br />

ING PISTON PUMP.<br />

<strong>The</strong> basic principle of the single-acting piston pump can be modified to<br />

cause water to be pumped on both the forward <strong>and</strong> the reverse strokes.<br />

Pumps thus modified are known a:$ double-acting piston pumps. 0 ther


I I‘)<br />

Helical Rotor Pumps<br />

Tilt helical rcjtor or screw-type<br />

purup is ;I Itlc~~it’i~a~i~~Il 01’ tilt2<br />

rotary type i)t’ cotlslaII t dispiscc-<br />

111cnt purrlp. <strong>The</strong> Iil;iitl clcllIctIls 01’<br />

tllc purllp ;trc lllc IIiglIly !~~~iisitcd<br />

nletlli rotor or screw it1 the fort11 ot<br />

3 Ileiicai. sin& thread worr11 <strong>and</strong><br />

the outer stritor nlade of rubber.<br />

Flexible 171ountinps allow tile rotor<br />

to rotate eccentrically within the<br />

st:ltor. prthng ;I corltitluc)us !;trel,r:I<br />

01 water forward alo~lg rhc cavities<br />

jr1 tilt2 stator. <strong>The</strong> water ;1iso acts as<br />

3 lubricant bctwecn the ti:‘;) clc-<br />

melItS of tile pump. Hclic;;! rotor<br />

puIllpS cm hc citficr 01’ tllc surt’licc


or deep well type <strong>and</strong> are usually driven by engines or electric motors. Fig. 8.8<br />

illustrates a deep well, helical rotor pump.<br />

VARIABLE DISPLACEMENT PUMPS<br />

<strong>The</strong> distinguishing characteristic of variable displacement pumps is the in-<br />

verse relationship between their discharge rates <strong>and</strong> the pressure heads against<br />

which they pump. That is to say, the pumping rate decreases as the pressure<br />

head increases. <strong>The</strong> opposite is also true, the pumping rate increases as the<br />

pressure head reduces. <strong>The</strong> two main types ot’ variable displacemer:t pumps<br />

used in small wells .are centrif~rlgal <strong>and</strong>@ pumps.<br />

Discharge<br />

Discharga 1<br />

Fig. 8.7 DOUBLE-ACTING, SEMI-ROTARY HAND PUMP. (From Deming Division<br />

of Crane Company. Salem. Ohio.)<br />

Centrifugal Pumps<br />

Centrifugal pumps are the most common types of pumps in general use.<br />

<strong>The</strong> basic principles of their operation can be illustrated by considering the<br />

effect of swinging a pail of water around in a circle at the end of a rope. <strong>The</strong><br />

force that causes the water to press outward against the bottom of the pail<br />

rather than run out at the open end is known as the centrifugal force. If a


hole were cut in the bottom of the pail. water would be discharged through<br />

the opening at a velocity which is related to the centrifugal force. Further,<br />

should an intake pipe be connected to an air-tight cover on the pail, a partial<br />

vacuum would be created inside the pail as waier is discharged. This vacuum<br />

could bring additional water into the pail from ;! supply placed at the other<br />

end of the intake Flpe within the 1imii of the suction lift created by the<br />

vacuum. Thus a continuous ilow of water could be maintained in a manner<br />

similar to that operating in a cen-<br />

trifugal pump. <strong>The</strong> pail <strong>and</strong> cover<br />

correspond to ihe casing of the<br />

pump, the discharge hole <strong>and</strong> in-<br />

take pipe correspond to the pump<br />

outlet <strong>and</strong> intake respective&,<br />

while the rope <strong>and</strong> arm perform the<br />

functions of the pump impeller.<br />

Centrifugal pumps used on small<br />

statw bmldod<br />

Fig.8.8 BEEP WELL ttEL.lc ;$?.<br />

‘ROTOR PUMP.<br />

weUs can be subdivided into two<br />

r,;ain types based on their design<br />

features. <strong>The</strong>se are volute pumps<br />

<strong>and</strong> tttrbirte or diffuser pumps. <strong>The</strong><br />

impellers of volute pumps are<br />

housed in spirally shaped casings<br />

(Fig. X.9) in which the velocity of<br />

the water is reduced upon leaving<br />

the impeller with a resulting in-<br />

crease in pressure. In turbine pumps<br />

the impellers are surrounded by<br />

diffuser vanes (Fig. 8. IO). <strong>The</strong>se<br />

vanes provide gradually enlarging<br />

passages through whic!l the velocity<br />

of the water leaving the impeller is<br />

gradually reduced, thus trans-<br />

forming the velocity head into pres-<br />

sure head.<br />

<strong>The</strong> conditions of use dcterminc<br />

the choice between volute <strong>and</strong> tur-<br />

bine pumps. <strong>The</strong> volute design is<br />

very commonly x+ed in surface-Lype pumps where pump size is not a limiting<br />

factor <strong>and</strong> design heads are low to medium. Deep wetl centrifugal pumps are,<br />

however, of the turbine type of design which is better suited to use where the<br />

diameter of the pump must be limited, in this case by the diameter of the<br />

well casing.<br />

<strong>The</strong> performance of a centrifugal pump depends greatly upon the design of<br />

its impeller. For example. the pump discharge against a given head can be<br />

increased by enlarging the diameter of the inlet eye agd the width of the<br />

impe%x. it is also customary to use a larger number of guide vanes (up to 12)<br />

in turbine pumps when a higher pressure head is desired. <strong>The</strong> extent to which


Fig. 8.9 VOLUTE-TYPE C’ENTRIFU-<br />

CAL PUMP.<br />

Dtffuser vane<br />

k:ig. 8.10 TURBINE-TYPE C’ENTRIFU-<br />

CAL PlJMP SHOWING (‘HAR-<br />

A~TERISTIC D I F 1; I! SE R<br />

VANES.<br />

operation. however. increase in direct proportion to the number of stages or<br />

impellers. For fxampte. the pressure tied uf 3 4-stage pump, me stage ot<br />

which devztops a pressure ot. 40 feet head of water, would be 4 times 40 or<br />

IhO feet of water. Fig. X.1 I shows a section through a Sstage deep well<br />

turbine pump which is, in effect. three pumps assembled in series with flow<br />

passing from one to the next <strong>and</strong> the head being increased with passage<br />

throug!i each stage.<br />

Jet Pumps<br />

Jet pumps, in reality. combine centrifugal pumps <strong>and</strong> ejectors to lift water<br />

from greater depths in wells than is possible through the use of surface-type<br />

centrifugal pumps when acting alone. <strong>The</strong> basic components of ejectors are a<br />

nozzle 2nd a venturi tube shown in Fig. S.l 2. <strong>The</strong> operating principles are as<br />

follows. <strong>Water</strong> under pressure is delivered by the centrifugal pump (mounted<br />

at ground level) through the nozzle of the ejector. <strong>The</strong> sudden increase in the<br />

velocity of the water as it passes through the tapered nozzle causes a reduc-<br />

tion in pressure as the water leaves the nozzle <strong>and</strong> enters the venturi tube. <strong>The</strong><br />

higher the water velocit y through the nozzle, the greater is the reduction in<br />

pressure at the entrance to the venturi tube. This reduction in pressure can,<br />

therefore, be made great enough to create a partial vacuum <strong>and</strong> so suck water<br />

from the welt through the intake pipe of the ejector <strong>and</strong> into the venturi tube.<br />

<strong>The</strong> gradual enlargement of the venturi tube reduces the velocity of flow with<br />

a minimum of turbulence <strong>and</strong> so causes a recovery of almost all of the water


Sboft<br />

Stage<br />

Impeller<br />

Strainer<br />

Fig. 8.1 I THREE-STAGE LINESHAFT<br />

DEEP WELL TURBINE<br />

PUMP.<br />

I 23<br />

Venturi -<br />

Screen-<br />

-<br />

I- Grout<br />

seal<br />

-Return pipe<br />

- Ejector<br />

~ Foot valve<br />

t------<strong>Well</strong> casing<br />

Fig. 8.12 JFT PUMP. (Adapted from<br />

Fig. 13. MQFZUQ~ of Individual<br />

<strong>Water</strong> Supply Systems. Pub lit<br />

Health Service Publication No.<br />

24. 1962.)


pre y.,,:~ 1; +-.b to, rourT the nozzle. <strong>The</strong> centrifugal pump then picks up the<br />

flow,sendirlgpart ot’i! :1,-::


epas possible without removing the whole pump assembly from the well.<br />

Greater flexibility can also be achieved by the use of a dual right-angle drive<br />

head to which two engines, two electric motors or one engine <strong>and</strong> an electric<br />

motor can be coupled. This arrangement permits the use of a st<strong>and</strong>-by power<br />

/<br />

Drive head assembly<br />

\<br />

, Gasoline engine<br />

\<br />

Flexible shaft coupling<br />

Prelubricatiori tube connected I<br />

to dimharoa aim \<br />

Pipe column assembly<br />

Air line<br />

Pump bowl assembly<br />

Stages<br />

u<br />

Filler gage<br />

Discharge<br />

pipe<br />

Fig. 8.13 ENGINE DRIalEN, LINESHAFT DEEP WELL TURBINE PUMP. (Adapted<br />

y;5..Pig. 116, <strong>Well</strong>s, Deptiment of the Army Technical <strong>Manual</strong> TMS-297,<br />

source <strong>and</strong> continuous operation of the pump by one source while the other<br />

is being serviced or repaired.<br />

Lineshaft pump installations must, however, be enclosed in pump houses<br />

<strong>and</strong>, partly as a result of this, are usually more costly than submersible pump<br />

installations. <strong>The</strong> shafts <strong>and</strong> bearings of lineshaft pumps also provide many more<br />

125


Check valve<br />

Radial bearing<br />

lmpetfers<br />

Pump intake<br />

Seat<br />

Electric motor<br />

Pressure equal-<br />

izing tube<br />

Thrust <strong>and</strong> radial<br />

bearing<br />

Fluid chamber<br />

Fig.8.14 CLJT-AWAYVIEWOFASUB-<br />

MERSIBLE PUMP. Wrorn F.<br />

E. Myers & Bra. Company.<br />

Ashl<strong>and</strong>, Ohio.)<br />

moving parts which are subject to<br />

both normal wear <strong>and</strong> that xcelera-<br />

ted by corrosion <strong>and</strong> abrasive s<strong>and</strong><br />

particles.<br />

Submersible Pumps<br />

Submersible pumps, though<br />

built during the past SO yetus. have<br />

only been extensively used over the<br />

last IS years. <strong>The</strong> increase in use<br />

coincided with design impLove-<br />

ments in the submersible motors,<br />

electric cables <strong>and</strong> water-tight seals.<br />

<strong>The</strong>se improvements made it possi-<br />

ble to achieve efficiencies compara-<br />

ble with those obtained from hne-<br />

shaft pumps <strong>and</strong> also long periods<br />

of trouble-free operation. <strong>The</strong> elin-<br />

ination of the long drive shaft (<strong>and</strong><br />

multip!e bearings with it) has not<br />

only eliminated the wearing <strong>and</strong><br />

maintenance problems associated<br />

with lineshaft pumps but has also<br />

reduced the problems created by<br />

deviations in the vertical alignment<br />

of a well. <strong>The</strong> use of submersible<br />

pumps also results in savings in in-<br />

stallation costs since pump houses<br />

are not usualiy required. <strong>The</strong> opera-<br />

tion of the motor at a depth of sev-<br />

eral feet in the well also considerably<br />

reduces noise levels. <strong>The</strong> entire pump<br />

<strong>and</strong> motor must, however, be with-<br />

drawn to effect repairs <strong>and</strong> to ser-<br />

vice the motor. <strong>The</strong> riced to do so,<br />

however, arises very infmquently.<br />

PRIMING OF PUMPS<br />

Friming is the name given to the process by which water is added to a<br />

pump in order to displace any air trapped in the pump <strong>and</strong> its suction pipe<br />

during shutdown periods. In other words, priming results in a continuous<br />

body of water from the inlet eye of the pump impeller downward through<br />

the suction pipe. Without this continuous body of water a centrifugal pump<br />

will not deliver water after the engine or motor has been started. Positive displacement<br />

types of pumps are less affected <strong>and</strong> need priming only to the extent<br />

necessary to seal Ieakage past pistons, valves <strong>and</strong> other working parts.<br />

<strong>The</strong> many devices <strong>and</strong> procedures used in obtaining <strong>and</strong> maintaining, a<br />

primed condition in pumps generally involve one or a combinaticn of the<br />

126


following: ( I) a foot-valve to retair water in the pump during shut-down<br />

periods, (2) a vent to perntit the t~aptt tit‘ trapped air. (-3) an ausilialy pump<br />

or other devics( pipe front an overhead tank) to fill the pump with water. (-I)<br />

use of a self-primin g tj,pe o1‘ construction ill the pump. Self-pl’inlirlg pumps<br />

usually have an ausiliary chamber integrated itlt~ the pump structure in selctt<br />

a way that the trapped air is exhausted as flte pump circulates the priming<br />

water.<br />

PUMP SELECTION<br />

<strong>The</strong> proper selection of a pump for installation ai a well involves the con-<br />

sideration of several factors. <strong>The</strong> followittg discusslon presents some c,f the<br />

more important factors<strong>and</strong> particularly those which are very often overlooked<br />

ahd need to be emphasized.<br />

<strong>The</strong> first factor to be considered must of necessity be the yield of the well.<br />

So logical as this may seem. it is a Factor that is often overlooked in pbntp<br />

selection for small wells. Tltere is no way ot’ extracting more M2ter fiOlll a<br />

well than that determined by its maximum yield. It is, therefore. foolhardy<br />

to select a pump of greater discharge capacity t!tatl the w:ll will yield. Maxi-<br />

mum we/i yields are usually determined by test pumping. For small wells,<br />

test pumping need not involve more than tlte pumping of the well at a specific<br />

rate or series of rates for a period of time in excess of :lte likely service re-<br />

quirements. <strong>The</strong> records of the test catt then be used :u determine the specific<br />

capacity.<br />

With the knowledge of the specific capacity <strong>and</strong> tlie estimated water de-<br />

m<strong>and</strong>s a suitable pumping rate can then be selected taking into consideration<br />

the provision of storage. Consideration may be given to the use of several hours<br />

of storage capacity <strong>and</strong> a high pumping rate in order to keep the number of<br />

pumping hours as low as possible. <strong>The</strong> advantages of so doing should be<br />

weighed against the use of a lower pumping rate for extended hours of pump-<br />

ing <strong>and</strong> the provision of lower storage capacity. <strong>The</strong> availability of electric<br />

power only for limited periods of the day or night would also influettce the<br />

decision. Having chosen a pumping rate, the expected drawdowtt in the well<br />

for that rate can then be estimated by dividing it by the specific capacit;l of the<br />

well. For example, a pumping rate of 30 gpm in a well with a specific capacity<br />

of 5 gpm/ft would create a drawdown of 30 divided by 5, that is. 6 feet. Adding<br />

the drawdown to the depth of the static water level below the ground surface<br />

gives the depth to the expected pumping water level. This dey:h to the pump<br />

ing water level is then used to choose between a surface-type ;Tump <strong>and</strong> a deep<br />

well pump. In so doing, it must be remembered Ihat :*easr)r-?; vari:ltions in the<br />

water table, extended pumping <strong>and</strong> interference from orher welis could cause<br />

the lowering of the pumping water level. Allowances should, therefore, be<br />

made for such possibilities where they are likely to occur. <strong>The</strong> use oi‘ deep<br />

well pumps would be indicated where the depth to the ptimping water level<br />

is 25 feet or more <strong>and</strong> the well is deep enough <strong>and</strong> large enough in diameter<br />

to accommodate a suitable pump. Surface-type pumps would otherwise be<br />

used with limited pumping rates if necessary.<br />

197


To storage<br />

ha<br />

I<br />

3 Power unit<br />

- Static udtkt level<br />

- <strong>Water</strong> kvel when<br />

pumping<br />

Submerged-intake<br />

installation<br />

Fig. 8.15 TOTAL PUMPING HEAD OF<br />

WATER WELL PUMP IN-<br />

CLUDES VERTICAL LIFT,<br />

h , PLUS FRICTION LOSSES<br />

IIt PIPE, hf, AND VELOCITY<br />

HIAD (may usually be neglect-<br />

.<br />

<strong>The</strong> next logical step is the<br />

estimation of the total pumping<br />

head which, with the pumping rate,<br />

determines the capaciry of the<br />

pump to be selected. <strong>The</strong> total<br />

pumping head, ht, can be estimated<br />

by adding the total vertical lift, he,<br />

from the pumping water level to<br />

the point of delivery of the water<br />

(Fig. 8.15) <strong>and</strong> the total friction<br />

losses, hf, occurring in the suction<br />

<strong>and</strong> delivery pipe. This estimate<br />

ignores the velocity head or head<br />

required to produce the flow<br />

through the system since this head<br />

can be expected to be negligible in<br />

most installations using small wells.<br />

<strong>The</strong> total vertical lift, he, includes<br />

the suction lift <strong>and</strong> the delivery<br />

head or head above the pump<br />

impeller when a surface-type pump<br />

is used (Fig. 8.2). <strong>The</strong> total friction<br />

losses, h , can be estimated with the<br />

use of f able B.10 in Appendix B.<br />

Pump manufacturers or their<br />

agents can then be consulted on the<br />

selection of a suitable pump to<br />

meet the estimated pumping capac-<br />

ity <strong>and</strong> suction conditions, where<br />

applicable. A number of other<br />

factors would affect the final selec-<br />

tion. Among these are the purchase<br />

price <strong>and</strong> cost of operating the<br />

pump; the extent of maintenance<br />

required <strong>and</strong> reliability of the main-<br />

tenance service available; the availability of spare parts; the ease with which<br />

repairs can be effected; the sanitary features of the pump; <strong>and</strong> the desirability<br />

to st<strong>and</strong>ardize on the use of a particular type <strong>and</strong> make of pump in order to<br />

reduce the diversity of spare parts. A guide to pump selection is provided in<br />

Table 8.1. In it is summarized the conditions under which the various types<br />

of pumps discussed in this chapter would normally be used <strong>and</strong> the<br />

advantages <strong>and</strong> disadvantages of each type. It must be emphasized that the<br />

table is designed for use only as a general guide to pump selection.<br />

SELECTION OF POWER SOURCE<br />

<strong>The</strong> zest of power can <strong>and</strong> often does constitute a major part of the cost<br />

of pumping. In view of the limited economic resources usually available to<br />

128


Fin. 8.16 W I N D M I L L . (<strong>Manual</strong><br />

operation of pump also pos-<br />

sible.)<br />

those persoIls <strong>and</strong> communities<br />

using small wells, it is very important<br />

that careful considerutioll be<br />

given to the selection of a power<br />

source. <strong>The</strong> type of power available<br />

will, in many cases, be the determining<br />

factor in the design of a<br />

small pumping installation. <strong>The</strong>re is<br />

normally a choice of four sources<br />

of power for operating Puntps on<br />

small wells. <strong>The</strong>se sources are man<br />

power, wind. electric motors <strong>and</strong><br />

internal combustion engines.<br />

Man Power<br />

Man power is. in many places,<br />

not only a cheap source, but, sometimes,<br />

the only one available for<br />

operating pumps on wells. It is, of<br />

course, the oldest known source. Its<br />

use is suited to individual water<br />

supply systems with small, intermittent<br />

dem<strong>and</strong>s. Sometimes elevated<br />

storage is provided to maintain<br />

a continuous supply. <strong>The</strong> use<br />

of man power would, normally, be<br />

restricted to pumping rates not<br />

exceeding about 10 gpm <strong>and</strong> suction<br />

lifts of no more than about 20<br />

feet. H<strong>and</strong> pumps, subject to repeated<br />

use by the general public,<br />

can often have abnormal maintenance<br />

problems due to the fracturing<br />

of thP !:<strong>and</strong> lever <strong>and</strong> cylinder,<br />

<strong>and</strong> 1:~ .,,,.,:,ive wear of the<br />

inner wall s.: i i ! !e cylinder, particularly<br />

when the water contains s<strong>and</strong>. <strong>The</strong> most sturdy Lypes of pumps should<br />

be used under such conditions. Manufacturers have been experimenting with<br />

various types of nletal construction of the levers, cylinders <strong>and</strong> cylinder<br />

linings in order to mlr;;mize the maintenance problems.<br />

Wind<br />

Wind is another very cheap source of power worthy of careful consideration<br />

in individual <strong>and</strong> small community water supply systems. Windmills (Fig.<br />

8.16) usually require the availability of winds at sustained speeds of more<br />

than 5 miles per hour. Towers are normally used to raise the windmills 15 to<br />

20 feet above the surrounding obstacles in order to provide a clear sweep of<br />

wind to the mills. Windmills usually drive reciprocating pumps through a<br />

connection of the pump rod from the mill to the piston rod of the pump.


Provision may also be made for pumping by h<strong>and</strong> during long periods of relti-<br />

tive calm. It is good prsctice to provide adequate clevrtted storage tu maintain<br />

the water supply during periods when there is insufficient wind. Windmills<br />

are normally manufxtured in siLes expressed in terms ot‘ the diameters ot<br />

their wheels. When ordering a windmill t‘wrn ;f mnut‘tlcturer. he must be<br />

supplied with information on the average wind velocity in addition to the<br />

required capacity <strong>and</strong> other relevant informut ion NI the pump. <strong>The</strong> operation<br />

<strong>and</strong> maintenance costs of windmills ;Lre usutllly very negiigible <strong>and</strong> strongly<br />

influence their use in communities wiiose financitil resources are inadequate<br />

to operate <strong>and</strong> maintain motor or engine driven pumps.<br />

Electricity<br />

Electricity. where available from a central supply at reasonable cost.<br />

is to be preferred over other sources of power. It would, however, be unwise<br />

tb mstall electric generators simply to provide a supply for operating a small<br />

pump. Electricity‘s great advantage is the fact that it can be used to provide a<br />

continuous. automatically controlled supply of water. <strong>The</strong> power source must<br />

be reliable <strong>and</strong> not subject to significant vol;age variations. Small electric<br />

motors are usually low in initial cost. require little maintenance <strong>and</strong> are cheap<br />

to operate.<br />

lnternd Combustion Engine<br />

Internal combustion engines (gasoline, diesel or kerosene) are o!‘ten used in<br />

areas where electric power is not available <strong>and</strong> winds are Infrequent or<br />

inadequate to meet the water supply dem<strong>and</strong>s. Qiesel engines, though usually<br />

the most costly to purchas c, are generally the best from the point of view of<br />

operation <strong>and</strong> maintenance. Internal combustion engines require more<br />

maintenance than electric motors <strong>and</strong> must always be attended by an<br />

operator. Good service is obtained if a regular routine tnaintenancc program is<br />

followed <strong>and</strong> a supply of spare parts always available.<br />

130


Type of Pump<br />

Reciprocating:<br />

1. Surface<br />

2. Deep <strong>Well</strong><br />

Rotary:<br />

1. Surface<br />

(gear or<br />

vane)<br />

2. Deep <strong>Well</strong><br />

(helical<br />

zotor)<br />

TABLE8.1~GUIDE TO PUMP SELECTION<br />

(Adapted from Table 7hforrnation on Pumps. <strong>Manual</strong> of Individual <strong>Water</strong> Supply Systems, U.S. Dept. of Health,<br />

Education & Welfare, Public Health Service Pub. No. 24, Revised 1962 j<br />

Practical<br />

Suction<br />

lift* (CO<br />

21<br />

L~suallv<br />

submerged<br />

Usual<br />

Pumpin<br />

lcpth I P t)<br />

Usual Pressure<br />

Heads .!ft of<br />

water)<br />

50-200<br />

Up to 600<br />

above the<br />

cylinder.<br />

50-150<br />

100-500<br />

Advantages<br />

1. Positive action.<br />

2. Discharge constam un-<br />

der variahlc hcadr.<br />

3. &cat fltxbility in<br />

mecling variable de-<br />

m<strong>and</strong>s.<br />

1. Pumps wlter containing<br />

s<strong>and</strong> <strong>and</strong> silt..<br />

5. Especially adapted to<br />

low capacity <strong>and</strong> high<br />

lifts.<br />

I. Positive action.<br />

2. Discharge constant un-<br />

der variable heads.<br />

3. Efficient operation.<br />

I. Same as surface-type<br />

rotary.<br />

2. Only one moving pump<br />

part in the well.<br />

Disadvantages<br />

I. Pulsating discharge.<br />

! Subject I ibration<br />

;rllJlloirc.<br />

I. Maintenance cost5 may<br />

be high.<br />

I. Llay cause destructive<br />

pressure if operated<br />

againht a closed valve.<br />

I. Subject to rapid \vear<br />

if wat:r contains s<strong>and</strong><br />

or silt.<br />

1. Wear of gears reduces<br />

efficiency.<br />

1. Subject to rapid wear<br />

if waler contains s<strong>and</strong><br />

or silt.<br />

Remarks<br />

. Best suited for capacities<br />

of S-25 gpni against<br />

modcratc to high head\.<br />

. AdaptablL to IlllIld<br />

operation.<br />

Best stnled for ION<br />

sprtd operation.<br />

. Semi-rotary type<br />

adaptahlc to h<strong>and</strong><br />

operation.<br />

. A cutless rubber<br />

stator incrcastis life<br />

of pump.<br />

I. Best suited for IOH,<br />

capacity <strong>and</strong> high hcadr.<br />

,-


132


Type of Pump<br />

b. Submersible<br />

turbine<br />

(multi-stage)<br />

Jet:<br />

1. Deep <strong>Well</strong><br />

Practical<br />

sue tion<br />

Lift* (ft)<br />

Pump <strong>and</strong><br />

motor sub.<br />

merged.<br />

20-I 00<br />

below the<br />

ground.<br />

(Ejector<br />

submerged<br />

5 t-t).<br />

usual<br />

Pumpin<br />

Depth ( B t)<br />

> 25<br />

> 25<br />

Usual Pressure<br />

Heads (ft of<br />

water)<br />

so-150<br />

Advantages --<br />

1. Same as surface-type<br />

turbine.<br />

2. Short pump shaft to<br />

motor.<br />

3. Plumbness <strong>and</strong> align-<br />

ment of well less cri-<br />

tical than for line-<br />

shaft type.<br />

4. Less maintenance<br />

problems due to wear-<br />

ing of moving parts<br />

than for lineshaft<br />

type.<br />

5. Lower installation <strong>and</strong><br />

housing costs than for<br />

lineshaft type.<br />

6. Lower noise levels<br />

during operation than<br />

for lineshaft type.<br />

1. Simple in operation.<br />

2. Does not have to be<br />

installed over the<br />

well.<br />

3. No moving parts in the<br />

well.<br />

4. Low purchase price <strong>and</strong><br />

maintenance costs.<br />

*Practical suction lift at sea level. Reduce lift 1 foot for each 1000 ft above level.<br />

Disadvantages<br />

I. Repair to motor or<br />

pump requires removal<br />

from well.<br />

2. Repair to motor may<br />

require shipment to<br />

manufacturer or his<br />

agent.<br />

3. Subject to abrasion<br />

from s<strong>and</strong>.<br />

I. Generally inefficient.<br />

!. Capacity reduces as<br />

lift increases.<br />

3. Air in suction or re-<br />

turn line will stop<br />

pumping.<br />

-<br />

Remarks<br />

I. Relatively recent<br />

design improvements for<br />

sealing of electrical<br />

equipment make long<br />

p% ciods of troubletree<br />

service possible.<br />

2. Motor should be pro-<br />

tected by suitable<br />

device against power<br />

failures.<br />

I. <strong>The</strong> amount of water<br />

returned to the<br />

ejector mcreases _. . with<br />

Increased lit t 5 I)“:<br />

of total water pumped<br />

at 51) ft lift <strong>and</strong> 7S?G<br />

at 100 ti lift.<br />

2. Generally rimitzd to<br />

discharge of about 20<br />

gpm against 159 ft<br />

maximum head.


OF<br />

Too great stress can never be placed on the need to provide sanitary<br />

protection for all known ground-water sources, whether in immediate use or<br />

not, since such sources may some time in the future be of great importance to<br />

the development of their 1o;alities.<br />

Small wells, of the type being considered in this manual, very often have<br />

relatively shallow aquifers as their sources of water. <strong>The</strong>se sources, in many<br />

cases, are merely a few feet below the ground surface <strong>and</strong> can often be<br />

reached without great difficulty by pollution from privies, cesspools, septic<br />

tanks, barnyard manure. <strong>and</strong> industrial <strong>and</strong> agricultural waste disposal. It also<br />

very often happens that privies <strong>and</strong> septic tanks are the only economically<br />

practicable means of sewage disposal in a small <strong>and</strong> sparse community which<br />

must for various reasons depend entirely upon a shallow ground-water source<br />

for its potable water supply. Such dependence may be due to the inability of<br />

a small community to meet the costs of 3 sophisticated treatment plant for<br />

available surface water. Many rural areas are also subjected to annual<br />

extended periods of drought when strearrs become completely dry <strong>and</strong><br />

shallow ground-water aquifers provide the only reliable sources of potable<br />

water. It is, therefore, of great importance that such sources be adequately<br />

protected.<br />

POLLUTION TRAVEL IN SOILS<br />

<strong>The</strong> sanitary protection of ground-water supplies must be based on an<br />

underst<strong>and</strong>ing of the basic facts relating to the travel of polluted substances<br />

thiough soils <strong>and</strong> water-bearing formations. It must be remembered that all<br />

water seeping into the ground is polluted to some degree, yet this water can<br />

later be retrieved in 3 completely satisfactory condition for domestic <strong>and</strong><br />

other human uses. Some purifying processes must be taking place within the<br />

soil 3s the water travels through il. Several studies have been made of<br />

“nature’s purifying action” by research workers in many parts of the world,<br />

particularly in Europe, India <strong>and</strong> the United States of America. <strong>The</strong>se studies<br />

have contributed very much to our knowledge of the processes involved in<br />

the natural purification of ground waters <strong>and</strong> the patterns <strong>and</strong> extent of flow<br />

of pollution in them. <strong>The</strong> basic findings are summarized in the succeeding<br />

paragraphs.<br />

<strong>The</strong> natural processes occurring in soils to purify water travelling through<br />

them are essentially three in number. <strong>The</strong> first two of these are the<br />

134


I<br />

mechanical removal of microorganisms (including disease-producing bacteria)<br />

<strong>and</strong> other suspended matter by fi‘ltration <strong>and</strong> sedimentation or settling.<br />

Filtration depends upon the relative sizes of the pore spaces of the soil<br />

particles <strong>and</strong> those of the microorganisms <strong>and</strong> other filterable material. <strong>The</strong><br />

finer the soil particles <strong>and</strong> the smaller the pore spaces between them, the<br />

more effective is the filtration process. Filtered material also tends to clog the<br />

pore spaces <strong>and</strong> thus help to improve the filtration process. Sedimentatron<br />

depends upon the size of the suspended material <strong>and</strong> the rate of flow of the<br />

water through the pore spaces. <strong>The</strong> larger the particles of suspended matter<br />

<strong>and</strong> the slower the rate of flow through the soil, the more efficient would be<br />

the sedimentation process. It is, therefore, seen that the porosity <strong>and</strong><br />

permeability of the soil are very important factors in the operation of the<br />

fdtration <strong>and</strong> sedimentation processes <strong>and</strong>, 3s 3 result, in the extent of travel<br />

of bacterial pollution in soils.<br />

<strong>The</strong> third factor is what is often termed the natural die-away of bacteria in<br />

soils. Bacteria which produce disease in man live for only limited periods of<br />

time outside of their natural host which is generally man or animals. <strong>The</strong>ir life<br />

spans are usually short in the unfavorable conditions found in soils. This<br />

property contributes considerably to the self-purification of ground water<br />

during its movement <strong>and</strong> storage in s<strong>and</strong> <strong>and</strong> gravel aquifers.<br />

<strong>The</strong> effect of filtration is, of course, completely lost <strong>and</strong> sedimentation<br />

somewhat reduced in ground waters travelling through large crevices <strong>and</strong><br />

solution channels in limestone <strong>and</strong> other such consolidated rocks, This<br />

explains the generally better microbiological quality of ground water<br />

obtained from s<strong>and</strong>s, gravels <strong>and</strong> other unconsolidated formations 3s against<br />

those obtained from the larger crevices, fissures <strong>and</strong> solution channels in<br />

consolidated rocks.<br />

While the above mentioned processes are effective against the travel of<br />

bacterial pollution in ground water <strong>and</strong> usually within short distances <strong>and</strong><br />

periods of time, they are not nearly 3s effective against the travel of chemical<br />

pollution. Chemical pollution, it will be seen later, persists much longer <strong>and</strong><br />

travels much faster in ground waters than does bacterial pollution. Chemical<br />

reactions with soil material do play some part in restricting the travel of<br />

chemical pollution but require more time than the other processes do in<br />

controlling bacterial pollution.<br />

Pollution (bacterial <strong>and</strong> chemical) in soils usually moves downward from<br />

the source until it reaches the water table <strong>and</strong> then along with the<br />

ground-water flow in a path which first gradually increases in width to 3<br />

limited extent <strong>and</strong> then reduces to final disappearance. Downward travel of<br />

bacteria through homogeneous soil above the water table has seldom been<br />

found to be more than about 5 feet. Upon reaching the water table, no<br />

pollution travel takes place against the natural direction of ground-water flow<br />

unless induced by the pumping of a well upstream of the pollution source <strong>and</strong><br />

with a circle of influence (upper surface of the cone of depression) that<br />

includes the pollution source. <strong>The</strong> horizontal path of the flow of bacterial<br />

pollution in s<strong>and</strong> formations from a point source, such as 3 well used to<br />

recharge an aquifer, has been found to reach 3 maximum width of about 6


feet before final disappearance at a distance \jf about 101) feet from the<br />

source. <strong>The</strong> corresponding distances for pit latrine sources have per~rally<br />

been smaller. <strong>The</strong> maximum distance of bacterial po:iution tlow is ot‘tcn<br />

reached several !lours (often less than 2 days) after ihe introduction of the<br />

pollution. Filtration <strong>and</strong> the natural die-aw:jy processes then cause a rapid<br />

reduction in the numbers of bacteria found <strong>and</strong> the extent of the path until<br />

eventually only the immediate vic-nity of the pollution source is found to be<br />

affected.<br />

Chemical poliutkrn follows a similar but much b;ider <strong>and</strong> longer path than<br />

that of bacterial pollution. Maximum widths of about 25 to XI feet <strong>and</strong><br />

lengths of about 300 feet flave been observed. Investigations have indicated<br />

that chemicsl pollution travels twice as fast as bacterial pollution.<br />

<strong>The</strong> above fmdings serve to emphasize the importance of the proper<br />

location of wells with respect to sources of pollution if contamination is to be<br />

avoided. <strong>The</strong>y also form the basis for the general rules which are applied in<br />

well location <strong>and</strong> construction <strong>and</strong> the siting of pit latrines. cesspools <strong>and</strong><br />

other such means of waste disposal in relation to ground-water sources.<br />

WELL LOCATION<br />

<strong>Well</strong>s should be located on the highest practicable sites <strong>and</strong> certainly on<br />

ground higher than nearby sources of pollution. <strong>The</strong> ground surface in the<br />

immediate vicinity of the well should slope away from it <strong>and</strong> be well drained.<br />

If necessary, the site should be built up to achieve this end. A special drainage<br />

system should be provided for waste water from public weils. It is good<br />

practice, whenever practicable, to off-set the pump installation <strong>and</strong> discharge<br />

pipe as far as possible from 3 public well. This. together with a good drainage<br />

system, ensures that no waste water accumulates in the immediate vicinity of<br />

the well to become 3 possible source of pollution or unsightly pools <strong>and</strong><br />

mosquito breeding grounds. if a well must be located down-hill from 3<br />

pollution source, then it should be placed at a reasonably safe distance away,<br />

depending upon the source <strong>and</strong> the soil conditions. Recommended minimum<br />

distances from various types of pollution sources are listed in Table 9.1.<br />

TABLE 9.1<br />

Pollution Source I Recommended Minimum Distance<br />

Cast iron sewer with leaded or I 10 ft.<br />

mechanical joints<br />

Septic tank or sewer of tightly<br />

join ted tile<br />

Earth-blit privy, seepage pit or<br />

drain field<br />

so ft.<br />

75 ft.<br />

Cesspool receiving r3w sewage 100 ft.<br />

136


<strong>The</strong>se minimum distances are meant to be no more than guides to good<br />

practice <strong>and</strong> may be varied its soil <strong>and</strong> other conditions require. <strong>The</strong>y should<br />

be applied only where the soil has filtering capacity equal to, or better than<br />

that of s<strong>and</strong>.<br />

WeiS location should also take into consideration accessibility for pump<br />

repair. cleanin g. treatment, testing <strong>and</strong> inspection. <strong>Well</strong>s located adjacent to<br />

buildings should be at least 2 feet clear of any projections such as<br />

over-hanging eaves.<br />

Chapters 4: 5 <strong>and</strong> 6 should be consulted for information concerning the<br />

design, construction <strong>and</strong> compietion aspects, respectively. of the sanitary<br />

protection of wells.<br />

SEALING ABANDONED WELLS<br />

<strong>The</strong> objectives of sealing ab<strong>and</strong>oned wells are ( i) the prevention of the<br />

contamination of the aquifer by the entry of poor quality water <strong>and</strong> other<br />

foreign substances through the well, (2) the conservation of the aquifer yield<br />

<strong>and</strong> artisean head where there is one, <strong>and</strong> (3j the elimination of physical<br />

hazard.<br />

<strong>The</strong> basic concept of proper seaiing of an ab<strong>and</strong>oned well is the<br />

restoration, as far as practicable, of the exis5ng geologic conditions. IJnder<br />

water-table conditions sealing must be effective to prevent the percolation of<br />

surface water through the well bore or along the outside of the casing to the<br />

water table. Sealing under artesian conditions must be effective in confining<br />

water to the aquifer in which it occurs.<br />

Sealing is usually achieved by grouting with puddled clay, cement or<br />

concrete. When grouting under water, the grouting material should be placed<br />

from the bottom 11p by methods that would avoid segregation or excessive<br />

dilution of the material. Grouting methods have been described in Chapter 5.<br />

It may be necessary; in some cases, to remove well casing opposite<br />

water-bearing zones to assure an effective seal. Where the upper 15 or 20 feet<br />

of the well casing was not carefully cemented during the original con-<br />

struction, this portion of the casing should be removed before final grouting<br />

for ab<strong>and</strong>onment.<br />

137


REFERENCES<br />

Acme Fishing Tool Company. Ac772e. Greutest IVUl?li’ irl Cubltj ‘Tools Sirm<br />

IYOU. Catalog. Parkersburg, West Virginia.<br />

American <strong>Water</strong> Works Association. National <strong>Water</strong> <strong>Well</strong> Association. .4 Ct’lt’A<br />

St<strong>and</strong>ard j&- Deep <strong>Well</strong>s. AWWA AIOO-hh. New York: AWA 111~~. lC)hb.<br />

Anderson. Keith E. (ed.). <strong>Water</strong> lt’e11 Harrdhook. Rolla, Missouri: Missouri<br />

<strong>Water</strong> <strong>Well</strong> Drillers Association. 1966.<br />

Baldwin. Helene L.. <strong>and</strong> C. L. McGuinness. A Primer ml Grourlti <strong>Water</strong>.<br />

United States De artment of the Interior, Geological Survey. Washington:<br />

Government Prin P ing Office. 1963.<br />

Bowman, Isaiah. <strong>Well</strong>-Driliitlg Methods. Geological Survey <strong>Water</strong>-Supply Paper<br />

257. Washington: Government Printing Office. 191 1.<br />

Decker. Merle G. Cable Tool FiMzg. <strong>Water</strong> <strong>Well</strong> Journal. Series of articles<br />

commencing Vol . 21,No. l.(Jan., 1967). pp. 14-lh,S9.<br />

Departments of the Army <strong>and</strong> the Air Force. <strong>Well</strong>s. TMS-297. AFM X5-23.<br />

Washington: Government Printing Office, 1957.<br />

Edward E. Johnson, Inc. Ground <strong>Water</strong> <strong>and</strong> Weils. St. Paul. Minnesota. 1906.<br />

Gordon, Raymond W. <strong>Water</strong> <strong>Well</strong> Drillirlg \tYth Cuhle Tools. Sourly Milwau-<br />

kee, Wisconsin: Bucyrus-El-ie Company, 195X.<br />

Harr, M. E. Groundwater aHd Seepage. New York: McGraw-Hill Book<br />

Company Inc., 1962.<br />

Livingston, Vern. Frown: Too-Thin-to-Plough Missouri. To: Just-Right-to-<br />

Drink <strong>Well</strong> <strong>Water</strong>, <strong>Water</strong> Works Engineering (May, 1957), pp. 493495,<br />

521.<br />

McJunkin, Frederick E. (ed.). International Program in Sanitary Engineering<br />

Design. Jetting Small Tubewells b-y H<strong>and</strong>. AID-UNC/IPSED Series Item<br />

No. 15. University of North Carolina, 1967.<br />

Meinzer, 0. E. Occurrence of Ground <strong>Water</strong> in the United States. Geological<br />

Survey <strong>Water</strong>-Supply Paper 4S9. Washington: Government Printing Office,<br />

1959.<br />

Outline of Ground-<strong>Water</strong> Hydrology. Geological Survey <strong>Water</strong>-<br />

Supply Paper 494. Washington: Government Printing Office, 1965.<br />

Miller, Arthur P. <strong>Water</strong> <strong>and</strong> Man’s Health. Washington: Department of State,<br />

Agency for International Development, 1962.<br />

New York State Department of Health. Rural <strong>Water</strong> Supply. Albany, New<br />

York, 1966.<br />

13s


State of Illinois. Department of Public Health, Division of Sanitary<br />

Engineering. I,‘lirmis li’afer WcN Cousfnrc-tiorl Cih. Springfield, Illinois,<br />

19h7.<br />

Todd, David Keith. Crort~lci I4’~rrr H_rxi~o/o~~. New York: John Wiley & S,ms,<br />

Inc., 1960.<br />

U. S. Department of Health. Education, <strong>and</strong> Welt‘tlre. Dri~lkiug h’arer<br />

St<strong>and</strong>ards. Public Health Service Publication No. 956. Washington:<br />

Government Printing Office. 19h2.<br />

. hlarrual of htlividual <strong>Water</strong> Supp[v LSystenls. Public Health<br />

Service Publication No. J-1. Washington: Government Printing Office.<br />

1963.<br />

U. S. Department of the Interior. lnterdepartmenlal Committee on <strong>Water</strong> for<br />

Peace. <strong>Water</strong> fur Peace. A Report of Backgrotmd Consideratiorzs <strong>and</strong><br />

Recol?lr)ZelldatiOtls on the <strong>Water</strong> for Peace Program Washington : Govern-<br />

ment Printing Office. 1967.<br />

Wagner, E. G., <strong>and</strong> J. N. Lanoix. <strong>Water</strong> Supp[v jiu Rural Areas <strong>and</strong> Small<br />

C~mtwmities. Geneva: World Health Organkation. 19s~).<br />

Wisconsin State Board of Health. Wisconsitl <strong>Well</strong> Corastntctiorl ami Pump<br />

tnsrallatim C&e. Madison, Wisconsin, I95 1.<br />

CREDIT FOR ILLUSTRATIObJS<br />

<strong>The</strong> authors wish to give credit to UOP-Johnson Division, Universal Oil<br />

Products Company. St. Paul, Minnesota for the use <strong>and</strong> adaptation of the fol-<br />

lowing illustrations: Figures 2.3.2.5,2.9,2.10,~.12.2.13,2.17.3.1.3.2.4.1.<br />

4.2, 4.3, 4.5, 4.7, 4.8, 4.10, 4.1 1, 5.16, 5.22, 5.23, 5.24, 5.25, 5.26. 5.29,<br />

5.30, 5.31, 5.32, 5.33, 5.34, 5.35, 5.36, 5.37, 5.38, 5.39, 5.40, 5.41, 6.1, 6.2,<br />

6.4, 6.5, 6.6,6.8, 7.1, 7.2, 8.2, <strong>and</strong> A.l.<br />

139<br />

f


T OF PE ICITY<br />

<strong>The</strong> coefficient of permeability, or permeability as it is usually referred to<br />

in practice, can be determined by both laboratory <strong>and</strong> fie!d experiments.<br />

<strong>The</strong> field experiments, or pumping tests as they are called, have the advantage<br />

over laboratory experiments in that they are performed on the aquifer<br />

matcrlals in their natural, undisturbed state. <strong>The</strong>y are, however, more<br />

complicated, time consuming, costly <strong>and</strong> beyond iLe scope of this book.<br />

Permeameters are used for laboratory determinations of permeability. <strong>The</strong><br />

simplest laboratory method for the determination of permeability uses a<br />

Fig. A.1<br />

-1o-<br />

ir:z<br />

-I-<br />

-s-<br />

-57<br />

-.-<br />

:,-L<br />

fz-.<br />

-a-<br />

-0<br />

.i<br />

--<br />

f”’<br />

.e ;<br />

r=.*<br />

constant head permeameter iiS<br />

follows. Flow under constant head<br />

or pressure is maintained through a<br />

chosen length, C, of the sample of<br />

aquifer material placed between<br />

porous plates !.n a tube of cross<br />

sectiona! area. A (Fig. A.l). <strong>The</strong><br />

device at the upper left of the<br />

figure is used to provide the flow<br />

under constant head. <strong>The</strong> rate of<br />

flow, Q, through ibe sample is<br />

obtained by measu.;. ,:, .he volume,<br />

V, of water discharged I:iio a grad-<br />

uated cylinder in a given time. t.<br />

<strong>The</strong> manometer tubes to the riglIt<br />

of the figure are used to measure<br />

the head loss, hI- h2, as the water<br />

flows through the length, f, of the<br />

sample. Care must be taken to<br />

expel any air trapped in the satnple<br />

before taking measurements.<br />

<strong>The</strong>n Qz-=<br />

V P(hl -h2)A<br />

CONSTANT-HEAD PERMEA-<br />

METER FOR LABORATORY<br />

DETERMINATlON OF COEFt<br />

II<br />

FECIENTS<br />

ITY.<br />

QF PERMEABIL-<br />

VV<br />

Giving P =<br />

\ (h, -h2) A t<br />

To obtain P in units of gallons per day per square foot (gpd/sq ft), V must<br />

be expressed in gallons, II, hl , <strong>and</strong> h2 in feet, A in square feet, <strong>and</strong> t in days.<br />

140


Unit<br />

USEFUL TABLES A<br />

-<br />

1 Centimeter 1<br />

1 hleter 100<br />

1 Kilometer 100,000<br />

1 Inch 2.54<br />

1 Foot 30.48<br />

1 Yard 91.44<br />

1 Mile 160,935<br />

Unit<br />

1 sq.<br />

centimeter<br />

1 sq.<br />

Meter<br />

1 sq.<br />

Inch<br />

1 sq.<br />

Foot<br />

1 sq.<br />

Yard<br />

1 Acre<br />

1 sq.<br />

Mile<br />

-<br />

-<br />

r Equivdents<br />

Square<br />

Zentimeters<br />

10,000<br />

TABLE B.l LENGTH<br />

Equivaleuts of First Column<br />

T -*-<br />

I<br />

Centi-<br />

Kilo-<br />

Meters<br />

Inches Feet Yards<br />

meters<br />

meters<br />

1<br />

6.452<br />

929<br />

8,361<br />

40,465,284<br />

-<br />

.9144 .00091-?<br />

1,609.3 1.6093<br />

Square Square<br />

Meters Inches<br />

.OOOl<br />

1<br />

.000645<br />

.0929<br />

.836<br />

4,047<br />

!,5 89,998<br />

TABLE B-2 AREA<br />

of First Column<br />

I<br />

.155<br />

1,550<br />

1<br />

144<br />

1,296<br />

5,272,640<br />

-<br />

I<br />

-<br />

141<br />

.3937 .0328 .u109<br />

39.37 3.2808 1.0936<br />

39,370 3,280.8 1,093.6<br />

1 .c)833 .0278<br />

12 1 .3333<br />

36 3 1<br />

63,360 5,280 1,7&o<br />

Square<br />

Feet<br />

.00108<br />

10.76<br />

.!I0694<br />

1<br />

‘9<br />

43,560<br />

27,878,400<br />

Square<br />

Yards<br />

.00012<br />

1.196<br />

.00077 2<br />

.I1 1<br />

1<br />

4,840<br />

3,097.600<br />

Acres<br />

: .(<br />

Miles<br />

DO00062<br />

.000621<br />

.621<br />

.05)0016<br />

.000189<br />

.0010568<br />

1<br />

1<br />

-<br />

Square<br />

Miles<br />

- -<br />

.000247<br />

-<br />

- -<br />

.000023<br />

.000207 -<br />

1 30156<br />

640<br />

-


Unit<br />

TABLE B.3 VOLUME<br />

Equivalents of First Column<br />

Cubic Cubic U.S. Imperial Cubic Cubic<br />

Centimeters Meters Liters Gallons Gallons Inches Feet<br />

1 Cu. Centimeter 1 .000001 .OOl .000264 .00022 .061 .0000353<br />

1 Cu. Meter 1 ,ooo.ooo 1 1,000 264.17 220.083 61.0:!3 35.314<br />

I Liter 1,000 .OOl 1 .264 .220 61.023 .0353<br />

1 U.S. Gallon 3.785.4 .00379 3.785 I .833 231 .I34<br />

1 Imperial Gallon 4,542.5 .00454 4.542 1.2 1 277.274 .I60<br />

1 cu. Inch 16.39 .0000164 .0164 .00433 .00361 I .000579<br />

1 Cu. 12oot 28,317 .0283 28.317 7.48 6.232 1,728 1<br />

1 Cu. Foot per Day<br />

1 U.S. Gallon per Min.<br />

1 Imp. Gallon per Min.<br />

1 U.S. Gallon per Day<br />

1 Imp. Gallon per Day<br />

TABLE B.4 FLOW<br />

U.S. Gallons<br />

Per Minute<br />

448.83<br />

.00519<br />

1<br />

1.2<br />

.000694<br />

.000833<br />

226.28<br />

Equivalents of First Column<br />

Imp. Gallons U.S. Gallons<br />

Per Minute Per Day<br />

374.03 646,323<br />

.00433 7.48<br />

.833 1,440<br />

1 1,728<br />

.000579 : 1<br />

.0006”3 ’ !.2<br />

188.57 j 125,850<br />

.c i.C:-~~<br />

-. -<br />

538.860 1.983<br />

6.233 .00002 3<br />

1,200 .00442<br />

1,440 .oos3<br />

.833 .00000307<br />

1 .0000036,8<br />

271,542 I


Unit<br />

Grams Kilograms<br />

1 Gram 1 .oo 1<br />

1 Kilogram 1000 1<br />

1Ounce<br />

(Avoirdupois) 28.349 .0283<br />

1 Pound<br />

(Avoirdupois) 453.592 .454<br />

1 Ton (Short) 907.184.8 907.185<br />

1 Ton (Long) 1.016.046.98 1.016.047<br />

Unit<br />

1 Watt<br />

1 Kilowatt<br />

1 Horsepower<br />

1 Foot Pound<br />

Per Minute<br />

1 Joule<br />

Per Second<br />

=i=<br />

Watts<br />

1<br />

1000<br />

746<br />

TABLE B.5 WEIGHT<br />

Equivalents of I‘izst Column<br />

Ounces / Pounds /<br />

(Avoir-<br />

dupois)<br />

I<br />

TABLEB.6 POWER<br />

Equivalents of First Column<br />

!<br />

Kilowatts Horsepower<br />

Foot Pounds Joules<br />

Per Minute Per Second<br />

TABLEB.7 VOLUMESANDWEIGHT EQUIVALENTS(<strong>Water</strong>at39.2"F)<br />

Unit<br />

1 Cu. Meter 1 1,000<br />

1 Liter .OOl 1<br />

1 U.S. Gallon .00379 3.785<br />

1 Imp. Gallon .00454 4.542<br />

1 Cu. inch .0000164 .0164<br />

1 Cu. Foot .0183 28.317<br />

1 Pound .00045 .154<br />

-<br />

1=<br />

I-<br />

Cubic<br />

Meters<br />

I<br />

Liters<br />

Equivalents of First ::olumn<br />

UIS.<br />

Gallons<br />

264.17<br />

.264<br />

1<br />

I’ .-<br />

.00433<br />

7.48<br />

. 17 -<br />

143<br />

Imp.<br />

Gallons<br />

-.-<br />

220.083<br />

.-- “0<br />

.833<br />

1<br />

.00361<br />

6.232<br />

.I<br />

-<br />

Cubic Cubic<br />

Inches Feet<br />

61.033 35.314<br />

61.023 .035 3<br />

‘31 .I34<br />

177.774 .I60<br />

1 .000579<br />

1,728 1<br />

17.72 .016<br />

1<br />

1,000<br />

746<br />

.0226<br />

1<br />

Pounds<br />

-.- ' 700.83<br />

-.- ’ ‘01<br />

8.333<br />

IO<br />

.0361<br />

62.32<br />

1


-<br />

B-8 PRESSURE<br />

1 Atmosphere = 760 mibreters of mercury at 32°F.<br />

29.921 inches of mercury at 32°F.<br />

14.7 pounds per square inch.<br />

2,116 pounds per square foot.<br />

1.033 kilograms per square centimeter.<br />

33.947 feet of water at 6:!“F.<br />

B.9 TEMPERATURE<br />

Degrees C = 5/9 x (F - 32) Degrees F = 9/5 C t 32<br />

Flow Rate in<br />

Gallons per Miwte<br />

TABLE B-10 FRICTION LOSS IN SMOOTH PIPE<br />

(approximate<br />

I<br />

head loss in feet per 1000 feet of pipe1<br />

1%<br />

10 20<br />

15 44<br />

20 79<br />

25 123<br />

30 178<br />

40<br />

50<br />

Nominal Pipe Size in Inches<br />

TABLE B-11 PIPE, CYLINDER OR HOLE CAPACITY<br />

Diameter (Inches) Gallons Per Foot<br />

2%<br />

1% 0.09<br />

2 0.16<br />

2% 0.25<br />

3 0.37<br />

4 0.67<br />

6 1.47<br />

8 2.61<br />

10 4.08<br />

12 5.86<br />

16 10.45<br />

18 12.20<br />

20 16.35<br />

24 23.42<br />

144<br />

4<br />

6<br />

9<br />

16<br />

25<br />

I<br />

2


B-1 2 DISCHARGE MEASUREMENT USING SMALL CONTAINER<br />

Discharge (Gallons per minute) =<br />

(Oil Drums. Stock Tanks. etc.)<br />

Volume of container (Gallons) x 60<br />

Time (Seconds) to fill container<br />

TABLE B.13 ESTIMATING DISCHARGE FROM A HORIZONTAL<br />

PIPE FLOWING FULL<br />

Horizontal<br />

Distance, x<br />

(Inches)<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

- 4<br />

DISCHARGE RATE (Gallons Per Minute)<br />

Nominal Pipe Diameter (Inches)<br />

1 1% 1 ‘h 2<br />

5.7 9.8 13.3 22.0<br />

7.1 12.2 16.6 27.5<br />

8.5 14.7 20.0 33.0<br />

10.0 17.1 23.2 38.5<br />

11.3 19.6 26.5 44.0<br />

12.8 22.0 29.8 49.5<br />

14.2 24.5 33.2 55.5<br />

15.6 27.0 36.5 60.5<br />

17.0 29.0 40.0 66.0<br />

18.5 31.5 43.0 71.5<br />

20.0 34.0 46.5 77.0<br />

21.3 36.3 50.0 82.5<br />

22.7 39.0 53.0 88.0<br />

145<br />

-<br />

2Y2<br />

31.3<br />

39.0<br />

47.0<br />

55.0<br />

62.5<br />

70.0<br />

78.2<br />

86.0<br />

94.0<br />

102.0<br />

109.0<br />

117.0<br />

125.0


TABLE B-14 ESTIMATING DISCHARGE FROM VERTICAL<br />

PIPE OR CASING<br />

Height, H<br />

(Inches)<br />

1%<br />

2<br />

3<br />

4<br />

5<br />

6<br />

8<br />

10<br />

12<br />

15 .<br />

18<br />

21<br />

24<br />

DISCHARGE RATE (Gallons Per Minute)<br />

Nominal Pipe Diameter, D (Inches)<br />

2 3 4<br />

23 43 68<br />

26 55 9?<br />

33 74 130<br />

38 88 155<br />

44 99 175<br />

48 110 190<br />

56 125 225<br />

62 140 255<br />

69 160 280<br />

78 175 315<br />

85 195 350<br />

93 210 380<br />

100 230 400<br />

146


TABLE B.15 ROPE CAPACITY OF DRUM OR REEL<br />

Rope Capacity (feet) = K (A+B)AxC<br />

Nominal Rope Diarnet er<br />

(IncheyF<br />

i/4 4.4<br />

I 2.8<br />

(Wire Rope Evenly Spooled)<br />

Outer layer of rope<br />

2.0<br />

1.4<br />

i/2 1.1<br />

147<br />

where A,B,C are in inches<br />

--<br />

<strong>and</strong> K<br />

has. values in table below<br />

Nominal Rope Diameter<br />

(Inches)<br />

K<br />

9116 .9


-z-<br />

TABLE B.16 DRILLING CABLE ROPE CAPACITIES<br />

Rope<br />

Diameter<br />

(Inches)<br />

(Left Laid - Mild Plow Steel - 6x19 Hemp Center)<br />

112<br />

9/16<br />

Approximate Recommended<br />

Working Load<br />

(Pounds)<br />

3,200<br />

4,200<br />

513 .66 5,000<br />

-314 .95 7,200<br />

;<br />

713 1.29 9,800<br />

1 1.68 - 12,600<br />

TABLE B.17 SAND LINE CABLE ROPE CAPACITIES<br />

Rope<br />

Diameter<br />

(Inches)<br />

(Coarse Laid - Plow Steel - 6x7 Hemp Center)<br />

Approximate<br />

Weight Per Foot<br />

(Pounds)<br />

Recommended<br />

Working Load<br />

(Pounds)<br />

114 .09 800<br />

S/l6 .15 1,200<br />

313 .21 1,800<br />

7/16 .29 2,400<br />

112 .38 3,200<br />

148


TABLE B.18 CASING LINE CABLE ROPE CAPACITIES<br />

(Non Rotating - Plow Steel - 18 x 7 Hemp Center)<br />

Rope Approximate<br />

Diameter Weight Per Foot<br />

(Inches) (Pounds)<br />

Recommended<br />

Working Load<br />

(Pounds)<br />

513 .hS 5,400<br />

314 1; 7,600<br />

713<br />

10,200<br />

TABLE B. 19 MANILA ROPE CAPACITIES (3-STRAND)<br />

Rope<br />

Diameter<br />

(Inches)<br />

318<br />

7116<br />

1:‘2<br />

!a/16<br />

518<br />

314<br />

7/3<br />

1<br />

Approximate Recommended<br />

Weight Per Foot<br />

(Pounds)<br />

Working Load<br />

(Pounds)<br />

.04 270<br />

.05 350<br />

.08 530<br />

.lO 690<br />

.13 880<br />

.17 1,080<br />

.23 1,540<br />

.27 1,800<br />

149


A<br />

Ab<strong>and</strong>oned well, I37<br />

Acid. hydrochloric. 49, 86, 109f.<br />

-, precautions in using, I I 1<br />

-, sulfamic, 109ff.<br />

- treatment, (see <strong>Well</strong> maintenance<br />

operations)<br />

Aerial photographs. 28. 30<br />

Agricultural wastes. effects on ground-<br />

water quality. 25. I34<br />

- water needs. 2<br />

- - use. 24<br />

Alignment. (see <strong>Well</strong> alignment)<br />

Alluvial plains, 30<br />

Altitude, effect on suction lift, I I s<br />

Aquifer, coastal, 24<br />

-, definition, 6<br />

-, depth of, 29<br />

-. extent of. 9<br />

- functions. I Ift’.<br />

-. hydrltulic cnnracteristics, 9<br />

-. shape of. 9<br />

-. stratified, definition, IS<br />

-. thickness of, IO. 13, 20. 29, 41<br />

-, t,ypes of. I Of.. (also see Artesian<br />

aquifer <strong>and</strong> <strong>Water</strong>-table aquifer)<br />

-m. width of, I4<br />

Area. cross-sectional. I3<br />

Artesian aquifer. 10. 13. 16. 30, 33. 52<br />

- head. I37<br />

- well, flowing, IO, 33. IO4<br />

- -.. non-flowing, IO<br />

Auger. h<strong>and</strong>, SS<br />

-, spiral. 56<br />

Bacteria, coliform. 104<br />

-. disease-producing, I 35<br />

-. iron, 49, 106. I IOf.<br />

bacterial growths, I I 1<br />

Bailers, 66. 68, 89, 99, 104<br />

Barnyard, 2S<br />

- manure, 134<br />

Basalt, 8<br />

-, breociated. 8<br />

Belt. intermediate. 6<br />

--, soil water, 6<br />

bits. (see Drilling methods)<br />

borehole. depth of, 88<br />

boring. (see Drilling methods)<br />

boulders. 9. 74, 88<br />

Boundary. effects. I7<br />

-, impermeable. 18<br />

-, negative. 18<br />

-. positive, 18<br />

Brackish-water rivers, 2-1<br />

Cable. (see Wire rope)<br />

- -tool percussion drilling, (see Drill-<br />

ing methods)<br />

Calcium hypochlorite, l04f., I1 I<br />

- -. stock solution, POS<br />

- -. storage of. 105<br />

Capillary forces, 6<br />

- fringe, 6<br />

- tube, 6<br />

B<br />

C<br />

151<br />

Carbon dioxide. 26, 48, 107<br />

Carbonate. 106, 109<br />

Casing, (see <strong>Well</strong> casing)<br />

- elevator, 70<br />

-shoe 68<br />

Cementation, 7, 1 S<br />

Cementing agents, 8. 1 S<br />

Cesspools, 23. 25, 134, 136<br />

Chemical analysis, 48, 108<br />

- constituents, 7<br />

- decomposition, 7<br />

- treatment of wells, (see <strong>Well</strong> maintenance<br />

operations)<br />

Chloride, 24<br />

Chlorination, (see <strong>Well</strong> disinfection)<br />

Chlorine treatment, (see <strong>Well</strong> maintenance<br />

operations)<br />

Circle of influence, 135<br />

Clay, 7, 106, 11 1<br />

-, bentonite, 7 1<br />

cemented, 8<br />

=: grouting with, 7Of.. I 13, I37<br />

-, screening of, 41<br />

Compaction, 7f.<br />

Concrete, 52, 137<br />

Conduit functiou of aquifers, I I ff.<br />

Cone of depression, 16ff., 135<br />

--- composite, 20<br />

--- : definition, 16<br />

Confined aquifer, 10<br />

Contaminated sources, 2<br />

- water, 2.70, 104<br />

Contamination, 23. 104, 136f.<br />

-+ routes of, through wells, 52<br />

Contour lines, 29<br />

- map of water table, 31<br />

Corrosion. 26, 37f.. 48f.<br />

-, control of, 26<br />

-, dissimilarity of metals, 48<br />

-., galvanic, 37<br />

- resistant materials, 33, 48ff.<br />

Corrosive waters, 26, 44, 48<br />

Cost, effects on pump selection, 126<br />

-- selection of power source,<br />

-2 8ff.<br />

- - well design, 33, 35. 40, so<br />

=: fishing operations, 86<br />

Crevices, 8. 135<br />

Cyanosis. 25<br />

Darcy’s Law, 12. 16<br />

Dental fluorosis, 25<br />

Deposition, 7<br />

Deposits, alluvial, 7, 9f.<br />

-, area1 extent of, 8<br />

-, deltaic. 7<br />

-, glacial, 7, 10<br />

-, lake, 9f.<br />

-, marine, 7, 9<br />

-, scale, 2Sf., 49<br />

-, slime, 11 I<br />

-, stream, 7,9<br />

-, thickness of, 8<br />

-, w%d-blown, 7, 9<br />

Design, well, 33ff., 75<br />

Development of wells, 36, 38, 42, SOf.,<br />

96ff.<br />

D


Development, artificially gravel-pazked<br />

wells, 103f.<br />

-, backwashing, high-vehxif” jetting,<br />

10lff.<br />

-. -, --- jetting tool, IOlf.<br />

-7 object of, 96 ’<br />

-, surging, 98ff.<br />

De-watering, well-point systems for,<br />

22<br />

Diameter, casing, 34, ~4<br />

-, driiled hole. 1, 54. 7 3<br />

Dip of formation. 29<br />

Discharge, natural, of aquifer. 18<br />

f&eases, communicable, 2<br />

-, diarrheal, 2<br />

-. gastrointestinal, 2<br />

-, viral. 2<br />

-, water-borne. 2<br />

Disinfection, (see <strong>Well</strong> disinfection)<br />

Disintegration. mechanical, 7<br />

Dispersing agents, 164, 1 11 f.<br />

Dolomite, 8<br />

Drawdown, 16f.. 31. 41, 107ff.<br />

-. definition, 16<br />

Drill bits, (see Drilling methods)<br />

- col!ar. 6 1. 74<br />

- stem. 61<br />

Drilling equipment, (see Drilling methods)<br />

- -, care <strong>and</strong> use of. 87ff.<br />

- fluid, functions of, blff., 78, 80<br />

- methods, SSff., 75<br />

- -, boring, SSf.<br />

- -. cable-tool percussion. 66ff.. 76<br />

-- -_-- advantages <strong>and</strong> disadvantages.<br />

69 ’<br />

-- . -_- , drill bit, 67<br />

--.-.--- 9 drilling jr&r,, 67<br />

-- -_- - rig, 66, 99<br />

c- ----<br />

l : fishing jars, 67<br />

- -, - - --. rope socket, 67, 93,<br />

(also see Wire line socket)<br />

--t----<br />

string of drilling<br />

tools. 66f. ’<br />

-- , driving, SSf.<br />

-- -. equipment, 56<br />

- ---I hydraulic percussion, ~9<br />

-- , - rotary, 39, SO, 60ff.<br />

--.--<br />

advantages <strong>and</strong> disadvantages,<br />

65f.’<br />

-- % - -, drill bit (simple), 63<br />

- -* -- -, - ms, 61<br />

-- -- . - collar. 6 I, 74<br />

- -, - -. - stem, 61<br />

--.- -, drilling equipment,<br />

simule. 62f.<br />

-- -- -- fluid, functions of,<br />

61ff: ’<br />

-_ -- - mud, properties of,<br />

63ff.’ ’<br />

- -. - - - rig, 6Off.<br />

-- 7 -_ : mud pump. 61, 102<br />

-- , - -, settling pit, 61f.<br />

-- -- storage pit. 6 1 f.<br />

- --I jetting,’ 57ff.<br />

-- , -, drill bit, 57f.<br />

--,--- equipment, S7f.<br />

- -, sludger, 59f.<br />

-- mud, 58,78. 81,96, 104<br />

- -, gelling property. 64, 104<br />

- -, properties of, 63ff.<br />

- -. thickness of, 64<br />

- string, length of, record keeping. 88<br />

- tools, (see Drilling methods)<br />

- -, care <strong>and</strong> use of, g?ff.<br />

Drilling tools, record of dimensions, 88<br />

- ---, storage, 88<br />

- -. tool joints, making up, 88<br />

Dti*:king water st<strong>and</strong>ards, United States<br />

Pu3lic Health Service. 2 3<br />

Dri;,e head, right-angle, 124f.<br />

- point, (see <strong>Well</strong> point)<br />

- shoe, (see Casing shoe)<br />

Driven wells, (see Drilling methods)<br />

Driving well casing, 68<br />

- - point, 56f., 82<br />

Drought, 3<br />

Dug well, 1 l2f.<br />

Electric motor, I 14, 120. 124<br />

- -, submersible, 126<br />

Engine. 114. 120, 124<br />

-, diesel. 130<br />

-, gasoline, 130<br />

-, kerosene, 130<br />

Equilibrium, definition. IS<br />

Erosion, 30<br />

Faults. 29<br />

Filtration, effects on ground-water qual-<br />

ity, 22, r35ff.<br />

Fish, definition, 85<br />

-. position of, 90<br />

Fishing jobs, 90ff.<br />

- -. broken wire line, 92f.<br />

- -, cylindrical objects, 93ff.<br />

- -, neck of rope socket. 93ff.<br />

- -, parted drill pipe, 90ff.<br />

- -, pin of tool, 93ff.<br />

-- , releasing locked jars, 95<br />

- operations, 86ff. -<br />

- --, preparations for. 88ff.<br />

- --.-preventive measures, 87f.<br />

- tools, circulating-slip overshot, 90f.<br />

- -, combination socket, 93ff.<br />

- - , die overshot. 81, 90<br />

- -, fishing jars, 67, 92ff.<br />

- -, imoression block. 89f.<br />

- -, jar’bumper. 95<br />

- -, sinker, 92<br />

- -. tapered fishing tap, 8 I, 9 I f.<br />

- --. wall hook, 9 I f.<br />

- -, wire line center spear. 92f.<br />

Fissures, 22, I35<br />

Flow, base, 3<br />

-, converging. I6f.<br />

-, direction of, 29<br />

-, rate of, 13f., 22f., 135<br />

-. resistance to, 14<br />

- toward wells. I6ff.<br />

Fluoride, 24f.<br />

Formation. consolidated, 7<br />

-, impermeable, 52<br />

-, laminated, 5 1<br />

-. penetrated, record of. 3 I, 6Sf.<br />

-. samples of. 59, 65f.<br />

- stabilization, 50ff.<br />

- -, material used, Slf.<br />

-, unconsolidated. I, 7, 34. 57, 66. I35<br />

Fractures, 8f.<br />

Friction, I I6<br />

- lossrs, I 28<br />

E<br />

F


Gelling, 64<br />

Geologic cross-sections. 2aff.<br />

- data, 28ff.<br />

- formations, 7ff.<br />

- maps, 29<br />

- processes, 9f.<br />

Geology, effect on water quality, 27<br />

Geo hysics, 28<br />

c,:“,, -g. 12% formation stabilization mate-<br />

-, haveI-pack material, Slf., 103<br />

-, uniform, of particles. definition, 1 s<br />

Granite, 7f.<br />

Gravel, 7, 9, 78<br />

--pack envelope, thickness of, 52,<br />

103f.<br />

- - material. grading of, Slf., 103<br />

--- , selection of, 5 1<br />

- packing of wells, soff., szff.<br />

- pits, 30<br />

Ground water, availability of, 3. 7<br />

- -, definition, 6<br />

-- -, depletion of, 3<br />

- -, discharge rate, 3,4<br />

- -, flow of, 4, 1Off.<br />

- -. importance of, 2f.<br />

- -, mining of, 3<br />

- -, natural purification process,<br />

134f.<br />

- -, origin, occurrence <strong>and</strong> move-<br />

ment, 2. 4ff.<br />

- -. quality of, 3. 4<br />

- -, rate of extraction, 4<br />

- -. rate of recharge (replenishment),<br />

3.4<br />

Ground-water development. 2, 2 8<br />

- --, exploration, 28ff.<br />

- - resources, development of, 3, 4<br />

- - --I management of, 3<br />

- - sources, 3. 134, 136<br />

-- - sapplies. sanitary protection of.<br />

134ff.<br />

Grout, cement, 7lff.. do, 84<br />

-7 -7 mixing, 7 1 f.<br />

-. -, placing, 54, I2f.<br />

-,--, time to hari;en, 73<br />

-. clay, puddled, /Of., 113. 137<br />

- pipe, 72f.<br />

Grouimg methods, 72f.<br />

- -, gravity placement, 72<br />

- -, inside-tubing, 72f.<br />

- -, outside-tubing, 73<br />

H<br />

Hardness, 2 5<br />

Herbicides. 27<br />

Hoisting p&, 70<br />

Hydraulic characteristics of aquifers,<br />

IOff.. 31<br />

- gradient, 13f., 16<br />

- percussion drilling, (see Drilling<br />

met hods)<br />

- rotary drilling, (see Drilling methods)<br />

Hydrogen sulfide, 26, 48<br />

Hydrologic cycle, 4<br />

Hydrologist, 28<br />

c<br />

I<br />

Impermeable layer, 10<br />

Incrustation, 48f., 108<br />

153<br />

Incrustation, reduction of, 1 osf.<br />

Incrusting deposits. I06ff.<br />

- waters, 49<br />

Industrial water heeds, 2<br />

Infiltration, 4. 18<br />

Insecticides, 27<br />

Interference, 18ff.. 127<br />

- , defimtion, 18<br />

Intermediate water, 6<br />

Interstices, 22<br />

Iron. 24, 26, 49<br />

- bacteria, 49, 106, I 10f.<br />

- hydroxide, 106f., 100, 11 I<br />

.I<br />

Jars, drilling, (see Drilling met hods)<br />

-, fishing, (see Fishing tools)<br />

Jetting, (see Drilling methods)<br />

-, high-velocity, well development,<br />

10 1 ff.<br />

-3 - -, with chlorine treatment. I 11<br />

-7 - -, with dispersing agents, 104<br />

L<br />

Lakes, 31<br />

Laminar flow, 13<br />

L<strong>and</strong> forms, 30f.<br />

- use. 30<br />

Lava. 8’<br />

Laxative effects. causative chemicals in<br />

water, 25f.<br />

Lead packer, 76<br />

- shot, 80, 84<br />

- slip-packer, 84<br />

- wool, 80, 84<br />

Leakage, 18<br />

Limestone, 7f.<br />

Location of wells. 2Off.. 25, 28, 30.<br />

136f.<br />

Loess. 7<br />

M<br />

Magma, 8<br />

Maintenance of wells, (see <strong>Well</strong> maintenance)<br />

Manganese, 24,49<br />

- hydroxide, 107. 109, 11 1<br />

Marble I 9<br />

Marsh funnel, 64f.<br />

- - viscosity, 65<br />

Methemoglobinemia, 25<br />

Mineral content of water, 23ff.. 48<br />

Minerals, solution in water, 23<br />

Mud balance. 64<br />

- cake, 64, 83. 99<br />

- wall, in boreholes, 52<br />

Mudstone, 8<br />

Multiple well systems, 18ff.<br />

N<br />

Natural purification processes in soils,<br />

134f.<br />

Nitrate, 25<br />

Nozzle, jetting tool, 10lf.<br />

Odors in ground water., 22, 26f.<br />

Organisms, disease-producmg, 22, 104,<br />

135<br />

Outcrop, 29<br />

Oxygen, dissolved, 26, 48<br />

0


P<br />

Particle classification, 43<br />

size analysis, (see Sieve analysis)<br />

Gicles, arrangement of, 14f.<br />

-, distribution of, 14f., 46<br />

-, packing of, 7, 14f.<br />

-, rounding of, 7<br />

-9 shape of, 9<br />

-, size of, 9, 14f.<br />

sorting of, 7<br />

&cent size, definition, 43<br />

Percolation, benefits of, 3, 2 3<br />

Percussion drilling, (see Drilling Met h-<br />

P%?eabiIity 12ff 31 43, 100. 135<br />

-, coefficiem of,“1 2ff.<br />

-. factors affecting. 14f.<br />

Permeable, 7f. -<br />

Pesticides. 27<br />

pII,<br />

PyTmetric surface, definition, 10, 13,<br />

Pipe, black iron, l09f.<br />

- clamp, 70, 85<br />

- joints, spigoted, 39<br />

-, plastic, 38f., 49f., 109f.<br />

-, polyvinyl chloride (PVC), 49<br />

- , slotted, 33, 38f.. 102<br />

Pit latrine, 136<br />

Pl.ains, coast al, 3 1<br />

-, river, 31<br />

Pollution, bacterial, 23, 135f.<br />

-, chemical, 135f.<br />

-. rate of travel, 136<br />

-, sources of, 23, 134ff.<br />

- travel in soils, 134ff.<br />

Polyphosphates, 104, 111<br />

Pore, 4ff., 11, 135<br />

Pores, continuity of, 14f.<br />

-, volume of, 14<br />

Porosity, 14f., 135<br />

-, definition, 11<br />

Porous, 7f.<br />

Power consumption, 107f.<br />

Precipitation, 4, 18<br />

Pressure, 12f., 16f., 26, 40, 101, 107,<br />

114ff., 121<br />

- aquifer, 10<br />

-. atmospheric, 1 15<br />

- differences, 13<br />

Privies, 23, 25, 134<br />

Public health, l<br />

Pulling ring, 77, 85<br />

Pump, 1 o, 114ff.<br />

-, capacity of, 127f., 13lff.<br />

-, centrifugal, 120ff.. 132f.<br />

-, -, turbine, l?lf., 132<br />

-, volute, 12l. 132<br />

=I constant displacement, 117ff., 131<br />

- -, helical rotor, 117, 1 19f.,<br />

TS4.131<br />

- -, reciprocating piston, 117,<br />

li4, 129f.<br />

-, --s-- discharge rate, 119<br />

- -,rotary,‘ll7 119 131<br />

=: deep well, 116, 1 18: 1 Zdff., 127,<br />

132f.<br />

-1 - -$ lineshaft, 124ff., 132<br />

-3 - -, submersrble, 74, 124, 126,<br />

133<br />

-. driving force, 114, 117<br />

-) h<strong>and</strong>-driven, 114, 119, 13 1, (also see<br />

manually-operated)<br />

- house, 125<br />

154<br />

Pump impeller, 12 If., 126, 128<br />

-, jet, 120, 122ff., 133<br />

-, Iineshaft., 124ff., 132<br />

-, manually-operated, 114, 118<br />

-, multi-stage, l22ff.<br />

-, pitcher, 118<br />

-, positive displacement, 124, 126,<br />

131, (also see constant displacement)<br />

-, power so:uce, electricity, 127, 129f.<br />

- --9 internal combustion engine,<br />

129f.<br />

-9 - -, man power, 129<br />

-9 - -, selection of, 128ff.<br />

-1 - -, wind, 129f.<br />

-, priming of? 126f.<br />

-, reduction m capacity, 106<br />

-, selection of, 127f.<br />

-, self-priming, 127<br />

-, st<strong>and</strong>ardization, 128<br />

-, submersible, 74, 124, 126, 133<br />

---I surface-type, 1 16, l 1 Sff., 127f.,<br />

13lf.<br />

--, variable displacement, 117, 1 ZOff.,<br />

132f.<br />

-1 - -, centrifugal, 1 ZOff., 132f.<br />

-,-- -, jet, 120, 122ff., 133<br />

-, vertical turbine, 74<br />

Pumping equipment, 33f., 114ff.<br />

-, hours of operation, record keeping,<br />

107<br />

- water level, 54, 116, 127<br />

Tif;;es of, 107, 109, 119f., 124,<br />

- test., 127<br />

Q<br />

Quality, ground water, 3f., 20, 22ff., 31,<br />

54<br />

_- 7 - -, chemical, 23ff., 48f.<br />

-- compared with surface<br />

Gter, 22f.<br />

--9 - -> microbiological, 22f., 135<br />

-1 - -, physical, 22<br />

R<br />

Radius of influence, 16<br />

Recharge. 17f.. 20<br />

-area, il, 18, 29<br />

- -, definition, 11<br />

- effects, 17f.<br />

River beds, 32<br />

Rocks, classification, 7ff.<br />

-, consolidated, 7, 22, 29, 135<br />

-, definition, 7<br />

-, deposition of, 7<br />

-, erosion of, 7<br />

-, extrusive, 8<br />

-, hard, 7<br />

-, igneous, 7ff., 24<br />

-, intrusive, 8<br />

-, metamorphic, 7, 9<br />

-, plutonic, 8<br />

--, sedimentary, 7ff.<br />

-, soft, 7<br />

-, transport of, 7<br />

-, unconsolidated, 1, 7, 29<br />

-, volcanic, 8f.<br />

-, weathermg of, 7<br />

Rope socket, 67, 93, (also see Wire line<br />

socket)<br />

Rotary drilling, (see Drilling methods)


s<br />

S<strong>and</strong>, 7,9? 119, 126, 129, 137<br />

-- anaylsn, (see Sieve analysis)<br />

- dune, 7, 31<br />

- pump, 68<br />

- pumping from a well, 46<br />

S<strong>and</strong>stone, 7f.<br />

Sanitary protection, ground-water<br />

supplies, 134ff.<br />

-- -, wells, S2ff.. 136f.<br />

- well seal, 52<br />

Screen, (see <strong>Well</strong> screen)<br />

Sediments, terrestrial, 9<br />

!%$II tganks, I34<br />

Sieve inalysis, 43, 46<br />

Sieve-analysis curves, 43ff.<br />

Sieves, st<strong>and</strong>ard sets of, 43<br />

Silt, 106, 111<br />

Siltstone, 8<br />

Site accessibility, effect on selection<br />

of well materials, 50<br />

Slotted pipe, 33, 38f., 102<br />

Sludger, drilling method, 59f.<br />

Sodium hypochlorite, 105, 111<br />

Solution channels, 8f., 22, 135<br />

Solvent, water as, 2 3<br />

Spacing of wells, 20ff.<br />

Specific capacity, 20, 42, 44, 107f., 127<br />

- retention, 12<br />

- yield, 12<br />

Spring, 29, 31<br />

Static water level, 16, 103, 106, 116<br />

Storage, aquifer, 3, 17<br />

- function of aquifers, 1 If.<br />

Stratification, 9, 14f., 46<br />

Stream patterns, 31f.<br />

Strike of formation, 29<br />

Subsurface water, 4ff.<br />

Suction, 11 Sf., 128<br />

- lift, 103, 114ff., 121, 128<br />

- -, definition, 114ff.<br />

Sulfate, 25, 106<br />

Surface drainage, contamination of<br />

wells, 104<br />

- evidence, ground-water exploration,<br />

28, 31f.<br />

- water, 3, 18, 134<br />

Surge block, 98<br />

- plunger, 98ff.. 109, 111<br />

- -. operation within well screen,<br />

101<br />

- -. solid-type, 99<br />

- -. valve-type, lOOf.<br />

Surging, chlorine treatment, 11 1<br />

-, well development, 98ff.<br />

Suspended matter in ground water, 22<br />

Swamps, 31<br />

Swedge block, 77, 84<br />

T<br />

Tastes in ground water, 22, 24, 26f.<br />

Temperature, 13, 2 2f., 116<br />

Terraces, 9, 30f.<br />

Texture of rocks, 7f.<br />

Total dissolved solids, 25f., 48<br />

Toxic chemicals in water, 26f.<br />

Trace elements, 26f.<br />

Transmissibility-, 14, 16f., 31<br />

coefficient of, definition 14<br />

Tra;lsmissivity, coefficient of: 14<br />

Transport, rock, 7<br />

Treatment, water, 22f., 26<br />

155<br />

U<br />

Unconfined aquifer, 10<br />

Uniform grading of particles, IS<br />

Uniformity coefficient, definition, 5 1<br />

V<br />

Vacuum, 116, 121f.<br />

Vadose water, 6<br />

Valley fill, 31<br />

Valleys, 9, 30f.<br />

Vegetation, 6, 30ff.<br />

Velocity, 12f., 16, 34,48, 107, 114,<br />

121f.<br />

- head, 128<br />

Vesicles, 8<br />

Volcanic rocks, 8f.<br />

W<br />

Wash-down bottom, 80f.<br />

Wastes, effects on ground-water quality,<br />

agricultural, 25, 134<br />

-, ----- , animal. 25, 134<br />

-9 - - - - -, human, 25<br />

-9 ----- , industrial, 27,<br />

134<br />

<strong>Water</strong> analysis, 48<br />

--bearing capacity, 7<br />

- - formation, clogging of, 96, 106<br />

-- - -9 compaction of, 96<br />

- - -9 pollution travel in, 134ff.<br />

- - -, stabilization by well development,<br />

96<br />

- level, pumpirg, 54, 116, I27<br />

- ‘-1-P definition, 16<br />

- -1 -I estimation of, 127<br />

- -, static, 16, 103, 106, 116<br />

- -9 ,, definition, 16<br />

- quahty, (see Quality)<br />

- supplies, importance of, If.<br />

- table, 13, 16, 56, 112, 127, 135,<br />

137<br />

- - contour map, 31<br />

- 2, definition, 10<br />

---table aquifer, 1 Of.., 13, 16, 30, 54<br />

--yielding capabilittes of rocks, 7ff.<br />

Weat hering of rocks, 2 9f.<br />

<strong>Well</strong> alignment, 73ff., 126<br />

- -9 checks on, 75<br />

- -, conditions affecting, 74<br />

- --, measurement of, 71<br />

- -, plumbness, 73ff.<br />

- -, straightness, 73ff.<br />

artificially gravel-packed, 36, 46,<br />


<strong>Well</strong> development, (see Development of<br />

wells)<br />

- disinfection. 96. 104f.. 1 11<br />

-- --I chlorine solution for, 104f.<br />

- -, flowing artesian wells, 105<br />

- drilling methods, (see Drilling<br />

rret hods)<br />

1: %%ia~~~of, 42. 44, 46, 51<br />

- hydraulics, IOff.<br />

-, intake section of, 33ff.<br />

- inventories, 28, 30f.<br />

- location, 2Off., 25, 28, 30<br />

--, relative to pollution sources,<br />

136f.<br />

- logs, 30f.<br />

- maintenance, 106ff.<br />

- - operations, 108ff.<br />

- - -, acid treatment, 109ff.<br />

- - -3 - -, placing acid, 109<br />

--- - -, precautions, 111<br />

- - -% ’ chlorine treatment, 109ff.<br />

--- dispersing agents, I 1 lf.<br />

- -, plrLning of, 107f.<br />

- -, record keeping, 107f.<br />

--. - -, frequency of observations,<br />

108<br />

- materials, corrosion resistant, 33,<br />

48ff.<br />

- -. selection of, J7ff.<br />

- -, strength requirements, 48, 49f.<br />

- performance, 33, 106<br />

- -, maintenance of, 106f.<br />

- point, installing. driving, 56f.. 82<br />

- -9 - in dug well, 112f.<br />

--.- . open hole method. 81<br />

-- -9 -9 pull-back method,‘81<br />

- -, types of, 37f.<br />

- pumd,-(see Pump)<br />

- rehabilitation, 106ff.<br />

-, s<strong>and</strong> producmg, 46<br />

- screen, 33ff., 102f.<br />

- -, continuous-slot type, 35f., 102f.<br />

- ---, design, influence of aquifer charactertstics,<br />

40ff.<br />

- - -9 - on well development, 96,<br />

102<br />

- -, oiameter of, 4Of., 47<br />

156<br />

<strong>Well</strong> screen, entrance velocity, 35, 40,<br />

47f.. 109<br />

-- l, installina. 75ff.<br />

- -9 -- in gr&el-packed wells, pull-<br />

back mtr hod. 82ff.<br />

-- -. - ‘etting method for setting<br />

COT ’ , .. ,.i :dsing <strong>and</strong> screen, 8 1<br />

- -, - iowering hook, 76f.<br />

- -, -, open hole method, 77ff.<br />

- -, -, pull-back method. 76f.. 81f.<br />

- -* -, wash-down met hod, SO’f.<br />

- -, length of, 4Of., 47<br />

- -, louver- or shutter-type, 36<br />

- -, open area, 34ff., 47<br />

- - openings, clogging of, 106<br />

- - -9 shape of, 34ff.<br />

- - -9 size of, 42ff.<br />

- - -9 st<strong>and</strong>ardization of sizes, 46<br />

- --, pipe-base, 37<br />

- -, pipe-size, 41, 47<br />

- -, recovering, s<strong>and</strong>-joint method,<br />

84ff.<br />

- - slots, plastic pipe, 38f.<br />

- -, telescope-size, 41, 47, 76<br />

- spacing, 20ff.<br />

-, upper terminal of, 52, 113<br />

-, useful life of, 33, 106<br />

<strong>Well</strong>s, arrangement of, 20ff.<br />

Wetting agent, 111<br />

Wind, 31, 129f.<br />

Windmill, 114, 129f.<br />

-, wind speed requirement, 129<br />

Wire line socket, 9 2 (also see RcJpe<br />

socket)<br />

- rope, care of, 87f.<br />

Y<br />

Y;::“; 8i X&, 31, 40f., 49, 106, 109, 113,<br />

.I<br />

-, specific: 1 If.<br />

-9 -, definition, 12<br />

Z<br />

Zone of aeration, 4ff.<br />

- - saturation, 4ff.<br />

a

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!