E-Mon E10579

(E-MPS-400-43-SPL) Split-Core Current Sensor, 400A, 1.7" X 1.3" Inner Diameter, One Piece

E10579
E10579

E-Mon E10579

(E-MPS-400-43-SPL) Split-Core Current Sensor, 400A, 1.7" X 1.3" Inner Diameter, One Piece

E10579
E10579
  • Split-Core Sensor
  • 400 Amp
  • 1.7" X 1.3" Inner Diameter
$162.25 Price $169.02
This item ships FREE
  • Split-Core Sensor
  • 400 Amp
  • 1.7" X 1.3" Inner Diameter
  • For use with Multi-Mon & PowerSmart+ Meters
  • E-Mon's patented 0-2V output split-core current sensors allow users to easily monitor energy usage in new or retrofit applications
  • Sensors are sized according to the meter they are installed with and are sized to fit the typical wire size for that amperage
  • E-Mon current sensors are installed inside the electrical panel and "snap" around the load wires to be monitored
  • The sensors can monitor anything from a single branch circuit, to multiple circuits, to the entire building
  • E-Mon current sensors can be installed up to 2,000 feet away from the meter (500 feet on Class 3x00 & Class 5000 meters) by extending the current sensor leads using #14-22 AWG wire (stranded/twisted not required)
  • 3' leads are supplied from the factory, consult local electrical costs for proper wiring size requirements
  • Current sensors can be installed around multiple load wires from the same source to provide a cumulative reading of usage for all of the loads
  • Note: Phase correspondence is required, and all loads must be from the same voltage source/transformer
  • Multiple sets of current sensors can be installed on one meter to provide a cumulative reading of multiple loads from different panels
  • Up to 3 sets of sensors can be installed on one meter
  • Note: Phase correspondence is required, all loads must be from the same voltage source/transformer, and all current sensors must be of the same amperage rating
  • Current sensors can be used for subtractive metering: an example of subtractive metering is one set of current sensors installed around the main load wires in a panel; a second set of current sensors is installed around the load wires going to a subpanel, but the current sensors are reversed during installation -- this will provide a net reading of the total panel less the sub panel
  • Note: Phase correspondence is required, all loads must be from the same voltage source/transformer, and all current sensors must be of the same amperage rating
  • Optional solid-core current sensors are available in 100 & 200 amp configuration, specify when ordering

The EMon E10579 is a 400A Split Core Current Sensor with a 1.7" X 1.3" Inner Diameter. The E10579 works with the Multi-Mon and PowerSmart+ meters.

More Information
Country of OriginUnited States
BrandE-Mon D-mon
ConditionNEW