Article

Permeability and Stability of Hydrophobic Tubular Ceramic Membrane Contactor for CO2 Desorption from MEA Solution

State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
*
Author to whom correspondence should be addressed.
Membranes 2022, 12(1), 8; https://doi.org/10.3390/membranes12010008
Submission received: 21 November 2021 / Revised: 15 December 2021 / Accepted: 16 December 2021 / Published: 22 December 2021
(This article belongs to the Section Membrane Processing and Engineering)

Abstract

:
Ceramic membrane contactors hold great promise for CO2 desorption due to their high mass transfer area as well as the favorable characteristics of ceramic materials to resist harsh operating conditions. In this work, a hydrophobic tubular asymmetric alpha-alumina (α-Al2O3) membrane was prepared by grafting a hexadecyltrimethoxysilane ethanol solution. The hydrophobicity and permeability of the membrane were evaluated in terms of water contact angle and nitrogen (N2) flux. The hydrophobic membrane had a water contact angle of ~132° and N2 flux of 0.967 × 10−5 mol/(m2∙s∙Pa). CO2 desorption from the aqueous monoethanolamine (MEA) solution was conducted through the hydrophobic tubular ceramic membrane contactor. The effects of operating conditions, such as CO2 loading, liquid flow rate, liquid temperature and permeate side pressure, on CO2 desorption flux were investigated. Moreover, the stability of the membrane was evaluated after the immersion of the ceramic membrane in an MEA solution at 373 K for 30 days. It was found that the hydrophobic α-Al2O3 membrane had good stability for CO2 desorption from the MEA solution, resulting in a <10% reduction of N2 flux compared to the membrane without MEA immersion.

1. Introduction

Carbon dioxide (CO2) capture plays a key role in reducing CO2 emissions. Among current technologies for CO2 capture, amine scrubbing is considered to be the most well-established one, dominating industrial application in the short-to-medium terms [1]. However, the most pressing issue in this technology is the regeneration of solvent, which represents approximately two-thirds of operating cost [2]. Thus, any improvement in reducing energy usage, such as employing an advanced stripping configuration, will contribute to lowering capture costs [3].
Current challenges associated with the conventional CO2 desorption (or solvent regeneration) process at least include two most significant ones: (I) the liberation of free CO2 molecules from their compound form and (II) the recovery of useful heat from evaporated water vapor. Specifically, a process of CO2 desorption from amine solutions undergoes the decomposition of unstable carbamate and/or bicarbonate species into CO2 and amine molecules and then the release of CO2 molecules from the liquid phase to the gas phase. Accompanied by the CO2 desorption process, a large amount of water in a reboiler needs to be evaporated to act as a stripping vapor due to low equilibrium CO2 partial pressure. Typically, a reboiler is operated at a high temperature allowed by solvent stability or by the available steam supply. Elevated temperature does increase CO2 desorption flux. However, it requires high heat duty. Even though part of the vapor from the reboiler is cooled down to condense water in the stripper, the overhead vapor contains 1–5 mol of water vapor per mol of CO2, depending on reboiler temperature and solvent employed [4]. This situation will cause a massive loss of latent heat in the overhead condenser. If an advanced separator is developed to greatly increase the mass transfer area for CO2, reboiler temperature (or mass transfer driving force) could be significantly reduced.
Membrane contactors are potential candidates applied for CO2 desorption given their advantages of high specific surface area and high operational flexibility as well as easy modularization [5,6]. To date, much fewer studies regarding membrane contactors have been conducted for membrane CO2 desorption compared with membrane CO2 absorption. Overall, one of the key obstacles that cause this situation is that CO2 desorption is usually carried out at elevated temperatures, e.g., at 100–120 °C for elevated-pressure desorption or at 70–100 °C for vacuum desorption [7,8]. High temperature and chemical conditions require membrane materials to exhibit excellent characterizes. In the past decades, some polymeric membranes, most notably polyvinylidene fluoride (PVDF) [5], polytetrafluoroethylene (PTFE) [9] and polypropylene (PP) [10], have been used for CO2 desorption. Despite these polymeric materials exhibiting advantages of high specific surface area for mass transfer, in general, they underperform on anti-chemical degradation, anti-thermal aging and mechanical strength [6]. These drawbacks of polymeric membranes make them easily susceptible to undesired variations in membrane structure and properties, such as in morphology, microstructure, hydrophobicity, etc., and even to liquid leakage after long-term exposure to the evaluated-temperature chemical solution. Thus, the employment of other promising membrane materials that can withstand long-term harsh conditions is essential.
Tubular ceramic membranes have higher mechanical strength and chemical and thermal stabilities than polymeric membranes as well as hollow ceramic membranes under harsh operating conditions [11]. They have been applied for different harsh conditions such as membrane reaction [12,13], membrane distillation [14,15], membrane desorption [16], water heat recovery [17] and other applications [18,19]. They are probably more suitable than polymeric membranes for membrane CO2 desorption. However, the permeability and stability of tubular ceramic membranes used for CO2 desorption from amine solutions can be rarely found in the open literature.
Generally, the materials used for membrane desorption are hydrophobic. The hydrophobic surface enables the creation of a high liquid entry pressure (LEP) to avoid the entrance of feed solution into pores. Consequently, only CO2 and water vapor are able to pass through the hydrophobic pores. The pores filled with gas and vapor usually have higher mass transfer performance for CO2 compared with those filled with liquid since membrane desorption processes are driven by temperature and pressure differences. Moreover, the hydrophobic pores without wetting will improve thermal and chemical resistance for long-term performance [6]. Original ceramic materials are hydrophilic because of the presence of massive hydroxyl groups (–OH) on their surface and pores [20]. Recently, extensive studies have confirmed that ceramic membranes can be endowed with stable hydrophobicity by grafting hydrophobic groups, such as organosilane, on the membrane interface [21]. Advances in hydrophobic modification increase the opportunities for the industrial application of ceramic membranes for CO2 desorption. In this work, hexadecyltrimethoxysilane (C16) ethanol solution was used for hydrophobic modification. The reasons for that are presented as follows. First, C16 is cheap, easy to store and less toxic compared to some commonly used modifiers, such as fluoroalkylsilanes (FAS). In addition, ethanol is a harmless and non-toxic solvent, can be considered as an environmentally friendly alternative to traditional grafting solvents such as acetone harmful solvents during the grafting process. Furthermore, the C16 ethanol solution had been used for the fabrication of hydrophobic zirconia (ZrO2) and alumina (Al2O3) membranes. The grafted ceramic membranes possessed high hydrophobicity and performed well in the processes of membrane absorption for gas separation [21], water–oil separation [22] and membrane distillation for desalination [14].
In this work, a hydrophobic tubular asymmetric alpha-alumina (α-Al2O3) ceramic membrane contactor for CO2 desorption from an aqueous monoethanolamine (MEA) solution was investigated in terms of mass transfer performance and stability. The mass transfer performance of the hydrophobic asymmetric ceramic membrane was experimentally evaluated in terms of the N2 flux and, more importantly, CO2 desorption flux under various conditions, including temperature, pressure and liquid flow rate. In addition, the stability of the original and hydrophobic membranes was evaluated in terms of the N2 flux, water contact angle and morphology before and after the immersion of the ceramic membrane in aqueous MEA solution at 373 K for 30 days.

2. Experiment

2.1. Materials

The ceramic membrane, which was fabricated by coating an α-Al2O3 membrane layer on the internal surface of tubular α-Al2O3 support, was supplied by Membrane Industrial Park, (Jiangsu, China). Reagent grade MEA with a purity of ≥99% was purchased from Shanghai Ling Feng Chemical Reagent Co., Ltd. (Shanghai, China). Commercial grade N2 and CO2 were supplied by Nanjing Ning Wei Medical Oxygen, Co., Ltd., Nanjing, China. Reagent grade hexadecyltrimethoxysilane (C16) with a purity of ≥85% (GC) was purchased from Shanghai Aladdin Chemical Reagent Co. Ltd., (Shanghai, China).

2.2. Preparation and Characterization of the Hydrophobic Membrane

The surface modifier was prepared by mixing the concentrated C16 with ethanol and a certain amount of nitric acid (about 3 mL 0.1 mol/L HNO3 per 1 L solution) to 0.1 mol/L C16 at room temperature for 24 h. The raw tubular membranes were dried and immersed into the modifier solution at 30 °C for 12 h. In the modification process, the –OCH3 group in silane molecule undergoes hydrolysis reaction to form silanol (R–Si–(OH)3) to possess hydrophobicity (Figure 1). The modified membranes were taken out and rinsed with deionized water and then dried at 110 °C for 6 h for curing the silane-modified silica to improve the stability of the hydrophobic membrane. Roughly, 1 L modified solution can be used for 5 membrane tubes. The membranes were stored at room temperature. The properties of the tubular asymmetric α-Al2O3 membrane to be characterized include water contact angle, gas permeation and morphology. The water contact angle of the ceramic membranes was measured by a contact angle analyzer (Dataphysics-OCA20, DataPhysics Instruments GmbH Co., Ltd., Filderstadt, Germany). The porosity of the membrane was characterized by an ellipsometry device (Complete EASEM-2000U, J.A. Woolam, Lincoln, NE, USA). The tests of gas permeation were carried out to investigate the effect of hydrophobic modification on membrane microstructure. Pure N2 was used to investigate the gas permeation. The test module containing a ceramic membrane with 11 cm length was prepared to determine the N2 permeance of the membrane. The upstream pressure was increased at 0.05 MPa intervals up to 0.4 MPa. The N2 was fed into the lumen side of the module, and the permeation rates were measured at 25 °C in the shell side using a rotor flow meter. The morphology of the membrane was assessed using field emission scanning electron microscopy (FESEM, S-4800, Hitachi High-Tech, Tokyo, Japan).
The N2 permeance flux can be calculated as follows:
J N 2 = G V m × A × Δ P × T 273.15
where JN2 is the N2 permeance flux, mol∙m−2∙s−1∙Pa−1; G is the volume flow rate of N2 from the permeation side, L/s; Vm is the gas molar volume, 22.4 L/mol; A is the area of the membrane layer, m2; ΔP is the transmembrane pressure difference, Pa; T is the temperature, K.

2.3. Sample Analysis

The solutions were prepared by mixing concentrated MEA with deionized water to desired concentrations. The MEA concentration was verified by titration against 1.0 mol/L hydrochloric acid (HCl) using methyl orange as an indicator. The liquid phase CO2 loading was determined in a Chittick apparatus by the standard method presented by the Association of Official Analytical Chemists (AOAC) apparatus [23]. The CO2 concentration in the gas phase was determined by a CO2 analyzer (COZIRTM Wide Range, CO2 Meter, Ormond Beach, FL, USA). A gas flow totalizer (D07-19B, Beijing Sevenstar Electronics Co., Ltd., Beijing, China) was used to measure the accumulated flow rate of the stripping CO2.

2.4. Experimental Apparatus and Procedure for Membrane CO2 Desorption

The schematic diagram of the experimental setup for CO2 desorption is shown in Figure 2. A hydrophobic tubular asymmetric α-Al2O3 membrane was encapsulated in a 304 stainless module to form the membrane contactor. The characteristics of the membrane contactor are presented in Table 1. The CO2-rich aqueous MEA solution in a heating tank was continuously pumped into the lumen side of the membrane contactor and then recycled back to the tank. The liquid flow rate was controlled by a rotameter (accuracy: ±2%). The temperatures and pressures of the solvent at the inlet and outlet of the membrane contactor were monitored using PT100-type thermal sensors (0−200 °C) and SIN-P300 pressure transmitters (0−0.6 MPa), respectively. In addition, the reduced pressure of the permeable side of the membrane contactor is generated by a vacuum pump and is determined by a pressure transmitter (−0.1–0 MPa). The vaporized H2O was extracted from the membrane contactor and then was condensed. The condensate was determined by a precise graduated cylinder. The stripped CO2 was online measured by a gas flow totalizer (D07-19B, Beijing Sevenstar Electronics Co. Ltd., Beijing, China), which enables converting it into the standard state by automatic temperature calibration and connecting to a computer to collect instantaneous and cumulative flow rates once per second.
The CO2 permeancec flux can be calculated as follows:
J C O 2 = F V m × A
where JCO2 is the CO2 permeance flux, mol∙m−2∙s−1; F is the flow rate measured by mass flowmeter, L/s.

2.5. Stability Study of the α-Al2O3 Membrane

The thermal and chemical stability of the membranes was studied as follows: the asymmetric α-Al2O3 membranes were immersed in a 5.0 mol/L MEA solution at 373 K for 30 days, as shown in Figure 3. After the 30 days of immersion, the membranes were taken out and washed with distilled water, then dried at room temperature. Then, the membrane samples were studied via FESEM analysis and gas permeation.

3. Results and Discussion

3.1. Characterization Results of the Hydrophobic Ceramic Membrane

To characterize the hydrophobic membrane, Fourier transform infrared spectrum (FTIR) determination was firstly conducted to see the bond variation. It can be observed in Figure 4 that the asymmetric stretching vibration peaks and symmetric stretching vibration peaks of –CH2– appeared at 2921 cm−1 and 2853 cm−1 on the modified spectrum, indicating that the silane molecules have been successfully grafted to the surface of the ceramic membrane. Subsequently, the cross-sectional and surface roughnesses of the original membrane and the modified membrane are determined via FESEM and AFM, as presented in Figure 5 and Figure 6, respectively. No obvious change can be observed from the FESEM and AFM images of the membranes before and after hydrophobic modification, indicating that the effect of the hydrophobic modification using C16 on membrane microstructure was insignificant.
The hydrophobicity of the grafted ceramic membrane was tested in terms of water contact angle. The water contact angle of the original membrane decreased sharply from 40° to 0° in a few seconds due to the presence of hydroxyl groups (−OH) on the membrane surface, as shown in Figure 7. By contrast, the contact angle of the grafted membrane kept stably greater than 130°, indicating the modifier had been satisfactorily grafted and the surface of the ceramic membrane was hydrophobic.
The N2 permeances of the original and grafted ceramic membranes at the transmembrane pressure of N2 ranging from 0.05 to 0.40 MPa, with the highest permeation fluxes of 1.01 × 10−5 and 0.967 × 10−5 mol/(m2∙s∙Pa), respectively, as shown in Figure 8. It indicates that the grafted ceramic membranes exhibited high hydrophobicity concurrently without causing much reduction of gas permeation. It was likely due to that the grafted C16 layer on the inner surface of pore channels was very thin. The thickness of the grafted layer was only a few nanometers (<3 nm) [24,25], which was much smaller than the pore sizes (0.1 μm for the top layer and 1.0 μm for the support layer). Therefore, the hydrophobic modification had an insignificant effect on the gas permeation.

3.2. Effects of Key Operating Conditions

Operating conditions are important to CO2 desorption performance. To investigate the effects of several key operating parameters on the membrane CO2 desorption performance, experiments were conducted at an MEA concentration of 5.0 mol/L, liquid temperature ranging from 363.15 to 373.15 K, CO2 loading ranging from 0.2 to 0.45 mol CO2/mol MEA, liquid flow ranging from 200 to 400 mL/min and permeate pressure ranging from 50 to 80 kPa.
The effect of CO2 loading on the CO2 stripping flux can be seen in Figure 9. With the decrease of CO2 loading, the CO2 stripping flux decreased significantly. This is because the decrease in CO2 loading would lower the CO2 equilibrium partial pressure, reflecting the smaller driving force for CO2 mass transfer. Meanwhile, an increase in liquid flow was of great benefit to improving the CO2 stripping flux. This is because as the liquid velocity increased, the liquid temperature and CO2 loading were little changed and maintained at high levels, thus keeping high mass transfer performance. In addition, an increase in the liquid flow resulted in reduced liquid phase mass transfer resistance which had a great effect on the overall mass transfer resistance. It should be noted that a high liquid flow means a fast circulation rate for liquid solution circulating between the membrane contactor and the reboiler, which will consume more pump energy. Therefore, it is important to choose an optimized liquid flow.
An increase in liquid temperature was of great benefit to increasing the CO2 stripping flux, as shown in Figure 10. This is because temperature directly affects CO2 equilibrium solubility and diffusion coefficients. The CO2 solubility in the MEA solution decreases exponentially with temperature [26], and the diffusivity increases in multiples of 4 by increasing the temperature by 10 K [27,28]. Thus, an increase in operating temperature leads to increases in both driving force and mass transfer coefficient for CO2 stripping. Moreover, an increase in the feed flow rate enabled reducing the temperature difference between the liquid bulk and the liquid–membrane interface, resulting in increased transmembrane pressure difference. The 363 K curve tended to a maximum as the feed flow rate further increased. This might be because the mass transfer in the feed side was negligible, and the transport in pore sizes governed the overall mass transfer process.
Regeneration pressure also impacts CO2 desorption flux. Lowering permeate side pressure enhanced the CO2 desorption flux, as shown in Figure 11. It can be explained that the decrease in the permeate side pressure is favorable for decreasing the CO2 partial pressure in the gas phase, thus improving the CO2 stripping driving force. However, a too low permeate side pressure will lead to the considerably high energy consumption of the vacuum pump. A moderate degree of vacuum condition is in favor of improving the CO2 membrane stripping performance, facilitating the CO2 transport in the permeate side, concurrently will not cost too much energy.
Compared to other studies reported on membrane contactors for CO2 desorption using MEA solution, the hydrophobic tubular asymmetric α-Al2O3 membrane exhibited competitive mass transfer performance, as shown in Table 2.

3.3. The Stability of the Modified Ceramic Membrane

In industrial applications, membrane stability is an important issue in the membrane process for CO2 desorption from amine solutions. It determines how long a membrane can be operated. Therefore, not only permeate flux but also the thermal and chemical stability is critical for a membrane to be employed in CO2 desorption. Here, the hydrophobically modified α-Al2O3 membrane after 30 days’ immersion in MEA solution was characterized and compared with that without immersion.
In this work, the contact angle, gas permeance and morphology of the immersed α-Al2O3 membrane were evaluated in order to investigate its thermal and chemical stability. As shown in Figure 12, the water contact angle of the immersed membrane was very close to that of the membrane without immersion. It means that the immersed membrane maintained good hydrophobicity. In addition, the gas permeation of immersed membrane the performance of unimmersed membrane at the transmembrane pressure of N2 ranging from 0.05 to 0.40 MPa, as shown in Figure 13. They had permeation fluxes of 0.932 × 10−5 and 0.847 × 10−5 mol/(m2∙s∙Pa), respectively. These results indicate that the MEA solution has a small effect on the stability of the modified membrane; however, the effect was acceptable.
The microstructure of the hydrophobic membranes before and after immersion was presented in Figure 14 to observe the effect of MEA solution on the stability of the modified membrane. As shown in Figure 14a,c, no obvious variation can be found between the surface morphology of the hydrophobic ceramic membrane before and after the immersion in MEA solution. From the cross-sectional FESEM images, it can be found that the near-surface of the ceramic membrane was partially corroded after immersion in MEA solution at 100 °C for 30 days, which explained why the N2 flux of the immersed membrane showed a little decrease. In the membrane desorption process, a hydrophobic membrane can prevent the permeation of reactive MEA into pores; thus, it is an effective way to reduce corrosion.

4. Conclusions

A hydrophobic ceramic membrane was fabricated via grafting a hexadecyltrimethoxysilane ethanol solution and tested in terms of water contact angle, pure N2 permeability and CO2 desorption performance. The results showed that the modification strategy enables the grafted ceramic membranes to exhibit hydrophobicity higher than 130° concurrently without causing much reduction of gas permeability (less than 5%) compared to the original membrane without modification. CO2 desorption from MEA solution was conducted through the tubular asymmetric membrane. The results demonstrated that the CO2 loading, liquid flow rate, liquid temperature and permeate pressure were the key parameters on the CO2 desorption flux. The CO2 flux was found to be 1.17 × 10−3 (mol·m−2·s−1) at feed temperature of 373 K, permeate side pressure of 60 kPa, MEA concentration of 5.0 mol/L, CO2 loading of 0.41, feed flow rate of 400 mL/min. Moreover, stability tests of immersing the membrane into a 5.0 mol/L aqueous MEA solution at 373 K for 30 days were also performed to investigate the stability of the hydrophobic α-Al2O3 membrane. The experimental results showed that the MEA solution did affect the membrane stability, however, was acceptable (less than 10%).

Author Contributions

Conceptualization, K.F. and Y.G.; methodology, Y.G., W.Q. and K.F.; software, Y.G.; validation, K.F., X.C., M.Q. and Y.F.; formal analysis, Y.G.; investigation, Y.G. and W.Q.; resources, K.F.,X.C., M.Q. and Y.F.; data curation, Y.G. and W.Q.; writing—original draft preparation, Y.G.; writing—review and editing, Y.G., W.Q., K.F.,X.C., M.Q. and Y.F.; visualization, Y.G., W.Q. and K.F.; supervision, K.F.; project administration, K.F.; funding acquisition, K.F., X.C., M.Q. and Y.F. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Key Research and Development Program of China (2020YFB0704502), the National Natural Science Foundation of China (21706114), and the Project of Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD).

Institutional Review Board Statement

Not Applicable.

Informed Consent Statement

Not Applicable.

Data Availability Statement

All the data supporting the findings of this study are available within the article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Vega, F.; Baena-Moreno, F.M.; Gallego Fernández, L.M.; Portillo, E.; Navarrete, B.; Zhang, Z. Current status of CO2 chemical absorption research applied to CCS: Towards full deployment at industrial scale. Appl. Energy 2020, 260, 114313. [Google Scholar] [CrossRef]
  2. Rochelle, G.T. Amine scrubbing for CO2 capture. Science 2009, 325, 1652–1654. [Google Scholar] [CrossRef] [PubMed]
  3. Oyenekan, B.A.; Rochelle, G.T. Alternative stripper configurations for CO2 capture by aqueous amines. AlChE J. 2007, 53, 3144–3154. [Google Scholar] [CrossRef]
  4. Jassim, M.S.; Rochelle, G.T. Innovative absorber/stripper configurations for CO2 capture by aqueous monoethanolamine. Ind. Eng. Chem. Res. 2006, 45, 2465–2472. [Google Scholar] [CrossRef]
  5. Rahim, N.A.; Ghasem, N.; Al-Marzouqi, M. Stripping of CO2 from different aqueous solvents using PVDF hollow fiber membrane contacting process. J. Nat. Gas Sci. Eng. 2014, 21, 886–893. [Google Scholar] [CrossRef]
  6. Vadillo, J.M.; Gomez-Coma, L.; Garea, A.; Irabien, A. Hollow fiber membrane contactors in CO2 desorption: A review. Energy Fuel 2021, 35, 111–136. [Google Scholar] [CrossRef]
  7. Qi, G.; Liu, K.; Frimpong, R.A.; House, A.; Salmon, S.; Liu, K. Integrated bench-scale parametric study on CO2 capture using a carbonic anhydrase promoted K2CO3 solvent with low temperature vacuum stripping. Ind. Eng. Chem. Res. 2016, 55, 12452–12459. [Google Scholar] [CrossRef]
  8. Ahn, H.; Kim, J.; Kim, J.H. Low-temperature vacuum stripping of CO2 from aqueous amine solutions using thin-film silicalite-filled PDMS composite membranes. Int. J. Greenh. Gas Control 2013, 18, 165–172. [Google Scholar] [CrossRef]
  9. Khaisri, S.; de Montigny, D.; Tontiwachwuthikul, P.; Jiraratananon, R. CO2 stripping from monoethanolamine using a membrane contactor. J. Membr. Sci. 2011, 376, 110–118. [Google Scholar] [CrossRef]
  10. Kosaraju, P.; Kovvali, A.S.; Korikov, A.; Sirkar, K.K. Hollow fiber membrane contactor based CO2 absorption-stripping using novel solvents and membranes. Ind. Eng. Chem. Res. 2005, 44, 1250–1258. [Google Scholar] [CrossRef]
  11. Chen, X.; Chen, T.; Li, J.; Qiu, M.; Fu, K.; Cui, Z.; Fan, Y.; Drioli, E. Ceramic nanofiltration and membrane distillation hybrid membrane processes for the purification and recycling of boric acid from simulative radioactive waste water. J. Membr. Sci. 2019, 579, 294–301. [Google Scholar] [CrossRef]
  12. Smart, S.; Liu, S.; Serra, J.M.; Diniz da Costa, J.C.; Iulianelli, A.; Basile, A. 8-Porous ceramic membranes for membrane reactors. In Handbook of Membrane Reactors; Basile, A., Ed.; Woodhead Publishing: Sawston, UK, 2013; pp. 298–336. [Google Scholar]
  13. Hussain, A.; Seidel-Morgenstern, A.; Tsotsas, E. Heat and mass transfer in tubular ceramic membranes for membrane reactors. Int. J. Heat Mass Transf. 2006, 49, 2239–2253. [Google Scholar] [CrossRef]
  14. Chen, X.F.; Gao, X.Y.; Fu, K.Y.; Qiu, M.H.; Xiong, F.; Ding, D.; Cui, Z.L.; Wang, Z.H.; Fan, Y.Q.; Drioli, E. Tubular hydrophobic ceramic membrane with asymmetric structure for water desalination via vacuum membrane distillation process. Desalination 2018, 443, 212–220. [Google Scholar] [CrossRef]
  15. Pagliero, M.; Bottino, A.; Comite, A.; Costa, C. Silanization of tubular ceramic membranes for application in membrane distillation. J. Membr. Sci 2020, 601, 117911. [Google Scholar] [CrossRef]
  16. Cui, Q.; Liu, S.; Xu, L.; Tu, T.; He, Q.; Yan, S. Modification of rich-split carbon capture process using ceramic membrane for reducing the reboiler duty: Effect of membrane arrangements. Sep. Purif. Technol. 2020, 235, 116148. [Google Scholar] [CrossRef]
  17. Tu, T.; Cui, Q.F.; Liang, F.H.; Xu, L.Q.; He, Q.Y.; Yan, S.P. Water recovery from stripping gas overhead CO2 desorber through air cooling enhanced by transport membrane condensation. Sep. Purif. Technol. 2019, 215, 625–633. [Google Scholar] [CrossRef]
  18. Gude, U.; Baumann, S.; Meulenberg, W.A.; Muller, M. Towards the development of materials for chemically stable carbonate- ceramic membranes to be used for CO2 separation in water-gas-shift reactors. Sep. Purif. Technol. 2019, 215, 378–383. [Google Scholar] [CrossRef]
  19. Xu, P.; Huang, Y.; Kong, X.; Gong, D.; Fu, K.; Chen, X.; Qiu, M.; Fan, Y. Hydrophilic membrane contactor for improving selective removal of SO2 by NaOH solution. Sep. Purif. Technol. 2020, 250, 117134. [Google Scholar] [CrossRef]
  20. Qiu, M.; Chen, X.; Fan, Y.; Xing, W. 1.11 Ceramic Membranes. In Comprehensive Membrane Science and Engineering, 2nd ed.; Drioli, E., Giorno, L., Fontananova, E., Eds.; Elsevier: Oxford, UK, 2017; pp. 270–297. [Google Scholar]
  21. Qiu, M.H.; Kong, X.L.; Fu, K.Y.; Han, S.X.; Gao, X.Y.; Chen, X.F.; Fan, Y.Q. Optimization of microstructure and geometry of hydrophobic ceramic membrane for SO2 absorption from ship exhaust. AlChE J. 2019, 65, 409–420. [Google Scholar] [CrossRef] [Green Version]
  22. Gao, N.; Li, M.; Jing, W.; Fan, Y.; Xu, N. Improving the filtration performance of ZrO2 membrane in non-polar organic solvents by surface hydrophobic modification. J. Membr. Sci. 2011, 375, 276–283. [Google Scholar] [CrossRef]
  23. Horwitz, W. Association of Official analytical Chemists (AOAC) Methods, 12th ed.; George Banta Company: Menasha, WI, USA, 1975. [Google Scholar]
  24. Tillman, N.; Ulman, A.; Penner, T.L.J.L. Formation of multilayers by self-assembly. Langmuir 1989, 5, 101–111. [Google Scholar] [CrossRef]
  25. Meth, S.; Sukenik, C.N. Siloxane-anchored thin films on silicon dioxide-modified stainless steel. Thin Solid Films 2003, 425, 49–58. [Google Scholar] [CrossRef]
  26. Weiland, R.H.; Rawal, M.; Rice, R.G. Stripping of carbon dioxide from monoethanolamine solutions in a packed column. AlChE J. 1982, 28, 963–973. [Google Scholar] [CrossRef]
  27. Versteeg, G.; Van Swaaij, W.P.M. Solubility and diffusivity of acid gases (carbon dioxide, nitrous oxide) in aqueous alkanolamine solutions. J. Chem. Eng. Data 1988, 33, 29–34. [Google Scholar] [CrossRef] [Green Version]
  28. Ko, J.J.; Tsai, T.C.; Lin, C.Y.; Wang, H.M.; Li, M.H. Diffusivity of nitrous oxide in aqueous alkanolamine solutions. J. Chem. Eng. Data 2001, 46, 160–165. [Google Scholar] [CrossRef]
  29. Khaisri, S.; Demontigny, D.; Tontiwachwuthikul, P.; Jiraratananon, R. Comparing membrane resistance and absorption performance of three different membranes in a gas absorption membrane contactor. Sep. Purif. Technol. 2009, 65, 290–297. [Google Scholar] [CrossRef]
  30. Scholes, C.A.; Kentish, S.E.; Stevens, G.W.; Demontigny, D. Asymmetric composite PDMS membrane contactors for desorption of CO2 from monoethanolamine. Int. J. Greenh. Gas Control 2016, 55, 195–201. [Google Scholar] [CrossRef]
  31. Lee, H.J.; Kim, M.K.; Park, J.H. Decompression stripping of carbon dioxide from rich monoethanolamine through porous hydrophobic modified ceramic hollow fiber membrane contactor. Sep. Purif. Technol. 2020, 236, 116304. [Google Scholar] [CrossRef]
  32. Fang, M.; Wang, Z.; Yan, S.; Cen, Q.; Luo, Z. CO2 desorption from rich alkanolamine solution by using membrane vacuum regeneration technology. Int. J. Greenh. Gas Control 2012, 9, 507–521. [Google Scholar] [CrossRef]
Figure 1. Schematic diagram of the hydrophobically modification process.
Figure 1. Schematic diagram of the hydrophobically modification process.
Membranes 12 00008 g001
Figure 2. Schematic diagram of the membrane CO2 stripping process.
Figure 2. Schematic diagram of the membrane CO2 stripping process.
Membranes 12 00008 g002
Figure 3. Schematic diagram of stability test.
Figure 3. Schematic diagram of stability test.
Membranes 12 00008 g003
Figure 4. Fourier transform infrared spectrum (FTIR) of the α-Al2O3 membrane before and after modification.
Figure 4. Fourier transform infrared spectrum (FTIR) of the α-Al2O3 membrane before and after modification.
Membranes 12 00008 g004
Figure 5. Scanning electron microscope (SEM) images of the α-Al2O3 membrane (a) before and (b) after modification.
Figure 5. Scanning electron microscope (SEM) images of the α-Al2O3 membrane (a) before and (b) after modification.
Membranes 12 00008 g005
Figure 6. Atomic force microscope (AFM) images of the α-Al2O3 membrane (a) before and (b) after modification.
Figure 6. Atomic force microscope (AFM) images of the α-Al2O3 membrane (a) before and (b) after modification.
Membranes 12 00008 g006
Figure 7. The water contact angle of the ceramic membrane before and after modification.
Figure 7. The water contact angle of the ceramic membrane before and after modification.
Membranes 12 00008 g007
Figure 8. The N2 flux of the ceramic membrane before and after modification.
Figure 8. The N2 flux of the ceramic membrane before and after modification.
Membranes 12 00008 g008
Figure 9. The effect of CO2 loading on CO2 flux at different liquid flow rates. Experimental conditions: T = 373 K, P = 60 kPa, CMEA = 5.0 mol/L.
Figure 9. The effect of CO2 loading on CO2 flux at different liquid flow rates. Experimental conditions: T = 373 K, P = 60 kPa, CMEA = 5.0 mol/L.
Membranes 12 00008 g009
Figure 10. The effect of feed flow rate on CO2 flux at different temperatures. Experimental conditions: P = 60 kPa, CMEA = 5.0 mol/L, CO2 loading = 0.45 mol CO2/mol MEA.
Figure 10. The effect of feed flow rate on CO2 flux at different temperatures. Experimental conditions: P = 60 kPa, CMEA = 5.0 mol/L, CO2 loading = 0.45 mol CO2/mol MEA.
Membranes 12 00008 g010
Figure 11. The effect of permeate pressure on CO2 flux at different liquid flow rate. Experimental conditions: T = 373 K, CMEA = 5.0 mol/L, CO2 loading = 0.45 mol CO2/mol monoethanolamine (MEA).
Figure 11. The effect of permeate pressure on CO2 flux at different liquid flow rate. Experimental conditions: T = 373 K, CMEA = 5.0 mol/L, CO2 loading = 0.45 mol CO2/mol monoethanolamine (MEA).
Membranes 12 00008 g011
Figure 12. The water contact angle of the ceramic membrane after 30 day of immersion.
Figure 12. The water contact angle of the ceramic membrane after 30 day of immersion.
Membranes 12 00008 g012
Figure 13. The N2 flux of the ceramic membrane after 30 day of immersion.
Figure 13. The N2 flux of the ceramic membrane after 30 day of immersion.
Membranes 12 00008 g013
Figure 14. Field emission scanning electron microscope (FESEM) images of the α-Al2O3 membrane before and after immersion in MEA solution. (a) surface and (b) cross-section of the unimmersed membrane; (c) surface and (d) cross-section of the immersed membrane.
Figure 14. Field emission scanning electron microscope (FESEM) images of the α-Al2O3 membrane before and after immersion in MEA solution. (a) surface and (b) cross-section of the unimmersed membrane; (c) surface and (d) cross-section of the immersed membrane.
Membranes 12 00008 g014
Table 1. Characteristics of the membrane contactor.
Table 1. Characteristics of the membrane contactor.
Membrane PropertiesValues
Membrane LayerSupport Layer
Mean pore size0.1 (μm)1.0 (μm)
Thickness40 (μm)2.0 (mm)
Porosity0.40.4
Tortuosity factor2.52.5
Membrane tube (OD/ID)12/8 (mm)
Module (ID)22 (mm)
Length600 (mm)
Note: OD and ID are outer and inner diameters, respectively.
Table 2. Performance of several kinds of membranes for CO2 desorption from MEA solution.
Table 2. Performance of several kinds of membranes for CO2 desorption from MEA solution.
MaterialCO2 Flux
(mol·m−2·s−1)
Absorbent Concentration
(mol/L)
CO2-Loading
(mol CO2/mol Absorbent)
Feed Temperature (K)Permeate Side Pressure (kPa)Ref.
PVDF3 × 10−45.00.45373100[29]
PDMS + Psf1 × 10−35.00.49373120[30]
PTFE5 × 10−45.00.45373100[9]
Al2O32.56 × 10−35.00.4535361[31]
PP2.2 × 10−43.40.5334352[32]
α-Al2O31.17 × 10−35.00.4137360This work
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Guo, Y.; Qi, W.; Fu, K.; Chen, X.; Qiu, M.; Fan, Y. Permeability and Stability of Hydrophobic Tubular Ceramic Membrane Contactor for CO2 Desorption from MEA Solution. Membranes 2022, 12, 8. https://doi.org/10.3390/membranes12010008

AMA Style

Guo Y, Qi W, Fu K, Chen X, Qiu M, Fan Y. Permeability and Stability of Hydrophobic Tubular Ceramic Membrane Contactor for CO2 Desorption from MEA Solution. Membranes. 2022; 12(1):8. https://doi.org/10.3390/membranes12010008

Chicago/Turabian Style

Guo, Yunzhao, Wenbo Qi, Kaiyun Fu, Xianfu Chen, Minghui Qiu, and Yiqun Fan. 2022. "Permeability and Stability of Hydrophobic Tubular Ceramic Membrane Contactor for CO2 Desorption from MEA Solution" Membranes 12, no. 1: 8. https://doi.org/10.3390/membranes12010008

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop