  • Page 3: Electrical Safety And Emissions Standards

    U.S. Federal Communications Commission Interference Statement The AT-IS230-10GP and AT-IS130-6GP comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) These devices may not cause harmful interference, and (2) these devices must accept any interference received, including interference that may cause undesired operation.
  • Page 4: Safety

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide The regulatory approvals of the product are listed here: Safety IEC/EN/UL 60950-1 (only AT-IS230-10GP)  CAN/CSA-C22.2 No.60950-1 (only AT-IS230-10GP)  UL 61010-2-201 (only AT-IS230-10GP)  CAN/CSA-C22.2 No.61010-2-201 (only AT-IS230-10GP)  EN 61010-2-201 (only AT-IS230-10GP) ...
  • Page 5: Shock

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Shock IEC 60068-2-27  MIL-STD-810G 516.6  Freefall IEC 60068-2-31  Vibration IEC 60068-2-6  MIL-STD-810G 514.6  RoHS Comply with AT-Doc # 612-001876  Warning In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
  • Page 6 Translated Safety Statements Important: The  indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” on our web site at http://www.alliedtelesis.com/ support.
  • Page 7: Table Of Contents

    Shock .....................................5 Freefall ...................................5 Vibration ..................................5 RoHS ....................................5 Preface ....................................13 Safety Symbols Used in this Document ........................14 Contact Allied Telesis ..............................15 Chapter 1: Overview ................................17 Hardware Components ..............................18 DIN Rail Bracket..............................21 Screw Holes for Wall Brackets ..........................21 Features ..................................22 IS Series Common Features ..........................22...
  • Page 8 Status LEDs ................................. 40 Twisted-Pair Port LEDs ............................41 SFP Slot LEDs ..............................42 PoE Status LEDs..............................43 Power Supplies................................45 AT-IS230-10GP ..............................45 AT-IS130-6GP ..............................45 Power Supply Redundancy ..........................46 Power Supply Connections ..........................46 Chapter 2: Begin Installation ............................47 Review Safety Precautions............................
  • Page 9 Figure 13: AT-IS230-10GP PoE Status LEDs: Ports 1-8......................43 Figure 14: AT-IS130-6GP PoE Status LEDs: Ports 1 - 4......................43 Figure 15: Pre-installed Components on the AT-IS230-10GP Front Panel ................58 Figure 16: Pre-installed Components on the AT-IS130-6GP Front Panel ................59 Figure 17: Pre-installed Components on the Top Panel.......................60 Figure 18: Pre-installed DIN Rail Bracket on the Back Panel....................60...
  • Page 10 Figures...
  • Page 11 Tables Table 1: Maximum Power Levels ............................30 Table 2: PoE and PoE+ Powered Device Classes ......................31 Table 3: Maximum Installation Site Temperatures Versus SFP Temperature Ratings ............34 Table 4: Status LEDs ................................40 Table 5: Twisted-Pair Port LEDs: Ports 1-10 ........................41 Table 6: SFP Slot LED ................................43 Table 7: PoE Status LED Descriptions ..........................44 Table 8: Ground Resistivity Recommendations ........................57...
  • Page 12 Tables...
  • Page 13: Preface

    Preface This guide contains the hardware installation instructions for the AT-IS230-10GP and AT-IS130-6GP switches. The preface contains the following sections: “Safety Symbols Used in this Document” on page 14  “Contact Allied Telesis” on page 15 ...
  • Page 14: Safety Symbols Used In This Document

    Preface Safety Symbols Used in this Document This document uses the following conventions. Note Notes provide additional information. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury.
  • Page 15: Contact Allied Telesis

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Contact Allied Telesis If you need assistance with this product, you may contact Allied Telesis technical support by going to the Support & Services section of the Allied Telesis web site at www.alliedtelesis.com/support. You can find links for...
  • Page 16 Preface...
  • Page 17: Chapter 1: Overview

    Chapter 1 Overview This chapter describes the hardware features for the AT-IS230-10GP and AT-IS130-6GP switches. This chapter’s sections are listed here: “Hardware Components” on page 18  “Features” on page 22  “10/100/1000Base-T Twisted-Pair Ports” on page 27  “Power over Ethernet” on page 30 ...
  • Page 18: Hardware Components

    Chapter 1: Overview Hardware Components The front panel of the AT-IS230-10GP switch is shown in Figure 1. Fiber System Status 1000Base-T LEDs twisted-pair ports Reset Button Console Management Fiber Port 1000Base-T twisted-pair PoE Status LEDs ports Figure 1. AT-IS230-10GP Switch Front Panel The front panel of the AT-IS130-6GP switch is shown in Figure 2.
  • Page 19: Figure 3: At-Is230-10Gp Switch Top Panel

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Figure 3 shows the components on the AT-IS230-10GP switch top panel. Grounding screw with Star washer DC PWR SUPPLY 2 Power/Alarm P-Fail Alarm Connector Contacts DC PWR SUPPLY 1 Figure 3. AT-IS230-10GP Switch Top Panel Figure 4 shows the components on the AT-IS130-6GP switch top panel.
  • Page 20: Figure 5: At-Is230-10Gp Switch Back Panel Features

    Chapter 1: Overview Figure 5 identifies the components on the AT-IS230-10GP switch back panel. Screw holes for wall bracket DIN rail bracket Screw holes for wall bracket Figure 5. AT-IS230-10GP Switch Back Panel Features...
  • Page 21: Din Rail Bracket

    Each switch comes with one DIN rail bracket pre-installed on the back panel. The bracket is compatible with DIN 35x7.5mm rails. Screw Holes for The AT-IS230-10GP back panel has six holes in the back panel for securing the two wall brackets. These brackets are included in the Wall Brackets accessory kit.
  • Page 22: Features

    “LEDs” on page 25  “Power/Alarm Connector” on page 25  “MAC Address Tables” on page 25  “AT-IS230-10GP Management Software” on page 25  “AT-IS230-10GP Management Methods” on page 25  “Installation Options” on page 25  “Additional Features” on page 26 ...
  • Page 23: At-Is230-10Gp Managed Features

    10/100/1000Base-T/TX RJ-45 Copper ports with  IEEE 802.3 af/at PoE. – AT-IS230-10GP switch - 8 ports with PoE. – AT-IS130-10GP switch - 5 ports total: 4 ports with PoE and 1 port without PoE. Two combo ports 100/1000Base-T/TX RJ-45/SFP for the ...
  • Page 24: Power Over Ethernet

    Port 5 of the AT-IS130-6GP switch does not support the PoE feature. SFP Slots The two SFP combo slots on the AT-IS230-10GP and the one SFP slot on the AT-IS130-6GP support 100M and 1000M optical transceivers. Note SFP transceivers must be purchased separately from the switch.
  • Page 25: Leds

    PoE Active status LEDs for each PoE twisted-pair port.  System Status LED (AT-IS230-10GP only).  Ring Master Active status LED (AT-IS230-10GP only).  Power/Alarm The switch has one connector on top of the switch which includes pins for the following functions:...
  • Page 26: Additional Features

    Chapter 1: Overview Additional Here are additional features for the IS Series switches: Features Reset button (AT-IS230-10GP only)  Two DC power supply input connections  Extended environmental range (Refer to “Environmental  Specifications” on page 99 for more information)
  • Page 27: 10/100/1000Base-T Twisted-Pair Ports

    The ports can operate at 10, 100, or 1000 Mbps. The switch can set the speeds automatically with Auto-Negotiation. Note In the case of the AT-IS230-10GP switch, you can manually set the speeds with the management software. The twisted-pair ports must be set to Auto-Negotiation to operate at 1000 Mbps. In the case of the AT-IS130-6GP switch, you cannot set the twisted-pair ports manually to 1000 Mbps.
  • Page 28: Maximum Cable Distance

    Chapter 1: Overview Note With the AT-IS230-10GP switch, you can disable Auto-Negotiation and set the duplex modes manually via the switch management. Speed and duplex mode settings can be set independently of each other on the ports. For example, the speed of a port can be configured manually while its duplex mode is established through Auto-Negotiation.
  • Page 29: Mdi/Mdix

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide MDI/MDIX The 10/100/1000 Mbps twisted-pair ports on the IS Series switches are IEEE 802.3ab compliant, with automatic MDI/MDIX detection. This feature automatically configures the ports to MDI or MDI-X depending on the wiring configurations of the end nodes.
  • Page 30: Power Over Ethernet

    Table 1 lists the switch ports that support PoE and the maximum power levels. The total available PoE power that the AT-IS230-10GP switch can supply from all the ports combined is 120 Watts. The total available PoE power that the AT-IS130-6GP switch can supply from all the ports combined is 90 Watts.
  • Page 31: Powered Device Classes For Poe And Poe

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Powered Device The PoE and PoE+ standards define five powered device classes. The classes are defined by the power requirements of the powered devices. Classes for PoE The classes are shown in Table 2. The IS Series switches support all five and PoE+ classes.
  • Page 32: Poe Budget

    If the total wattage requirements exceed the PoE budget on the AT-IS130-6GP switch, power will be delivered to the ports based on the sequence of being plugged in. In the case of the AT-IS230-10GP switch, power is delivered to specific ports using a mechanism referred to as port prioritization - refer to “Port Prioritization”...
  • Page 33: Port Prioritization

    AT-IS230-10GP Switch You can configure the port priority feature using the management software. There are three priority levels: Critical, High, and Low.
  • Page 34: Sfp Slots

    Chapter 1: Overview SFP Slots Each SFP slot supports Ethernet 100/1000Base fiber optic, MSA- compliant SFP transceivers. You can use the transceiver to connect the switch to other network devices over large distances, build a high-speed backbone network between network devices, or connect high-speed devices, such as servers, to your network.
  • Page 35: At-Is230-10Gp Console Port

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide AT-IS230-10GP Console Port The Console port is a serial RS-232 port offered on the AT-IS230-10GP switch only. You can access the management software to configure the features via the Console port. Management sessions conducted through the Console port are called local management sessions because you have to be at the location of the switch.
  • Page 36: At-Is230-10Gp Reset Button

    Chapter 1: Overview AT-IS230-10GP Reset Button The Reset button is only available on the AT-IS230-10GP switch and it resets the switch. You might reset the switch if it is experiencing a problem. The reset button is recessed in the chassis. To press it, use a straightened paper clip or similar object.
  • Page 37: Ground Screw

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Ground Screw The ground screw is used to connect the chassis to the earth ground at the installation site. The instructions for connecting the post are provided in the paragraph, “Connect Ground Wire” on page 78. Warning The switch must be connected to an earth ground.
  • Page 38: Power/Alarm Connector

    The power supply requirements for both the AT-IS230-10GP and AT-IS130-6GP models are described in “Power Supplies” on page 45. Allied Telesis does not sell or provide power supplies for these product. P-Fail Alarm You can specify the type of Alarm policy that will activate the P-Fail alarm relay contacts when the fault is detected.
  • Page 39: Figure 8: Example Of The P-Fail Alarm Relay Circuit

    LED on. When the switch detects that all its ports have links again, it opens the circuit, which turns off the LED. Note External alarm devices are not available from Allied Telesis. Circuit open - LED off Circuit closed - LED on...
  • Page 40: Leds

    “SFP Slot LEDs” on page 42  “PoE Status LEDs” on page 43  Status LEDs The status LEDs are defined in Table 4. Table 4. Status LEDs AT-IS230-10GP AT-IS130-6GP State Description Solid System is operating normally Green System is powered down, there is a system crash or an operation is initiating.
  • Page 41: Twisted-Pair Port Leds

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Twisted-Pair Port Twisted-pair ports have two LEDs. LEDs The AT-IS230-10GP twisted-pair port LEDs are identified in Figure 9. Link/Activity LED (L/A) Speed LED (SPD) Figure 9. AT-IS230-10GPTwisted-Pair Port LEDs: Ports 1-10 The AT-IS130-6GP twisted-pair port LEDs are identified in Figure 10.
  • Page 42: Sfp Slot Leds

    10 Mbps. SFP Slot LEDs Each SFP slot has one LED. The AT-IS230-10GP SFP LEDs for Combo ports 9 and 10 are shown in Figure 11. SFP LEDS Figure 11. AT-IS230-10GP SFP LEDs: Ports 9 and 10 The AT-IS130-6GP SFP LED for port 6 are shown in Figure 12.
  • Page 43: Poe Status Leds

    The PoE Status LEDs are shown in a separate group from the PoE ports themselves. The AT-IS230-10GP PoE Status LEDs are shown for twisted-pair ports 1 - 8 are shown in Figure 13. Figure 13. AT-IS230-10GP PoE Status LEDs: Ports 1-8 The AT-IS130-6GP PoE Status LEDs are shown for twisted-pair ports 1 - 4 are shown in Figure 14.
  • Page 44: Table 7: Poe Status Led Descriptions

    Chapter 1: Overview Table 7. PoE Status LED Descriptions State Description Solid Green PoE is active on the port and is delivering power to a powered device. This LED state indicates one of the following conditions: - The port is connected to a non-PoE device. - The PD is powered off.
  • Page 45: Power Supplies

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Power Supplies Allied Telesis does not sell power supplies for the IS Series products. Power supplies can be purchased from power supply manufacturers. Note See “Power Specifications” on page 100 for the DC power supply output requirements.
  • Page 46: Power Supply Redundancy

    Chapter 1: Overview Here are the power supply requirements for the AT-IS130-6GP switch: 48V, 2.5A (per port 15W) (+18.75%/-6.25%)  54V, 2A (per port 30W) (+5.55%/-5.55%) 48V, 2.5A (par port 15W) (+18.75%/-6.25%) 54V, 2A (par port 30W) (+5.55%/-5.55%) The DC power supply must be capable of supplying the above ...
  • Page 47: Chapter 2: Begin Installation

    Chapter 2 Begin Installation The chapter contains the following sections: “Review Safety Precautions” on page 48  “Safety Precautions With Electricity” on page 55  “Review Site Requirements” on page 56  “Verify Package Contents” on page 58 ...
  • Page 48: Review Safety Precautions

    Chapter 2: Begin Installation Review Safety Precautions Please review the following safety precautions before beginning the installation procedures. Note Safety statements that have the  symbol are translated into multiple languages in the Translated Safety Statements document at www.alliedtelesis.com/support. Caution CAUTION: FOR USE IN A CONTROLLED ENVIRONMENT ATTENTION: Pour utilisation dans un environnement contrôlé...
  • Page 49: Ground Connection

    Safety AT-IS230-10GP Instructions The AT-IS230-10GP switch can be powered by using SELV +24-48VDC. All circuits should be connected to a SELV circuit. 1. Make sure the voltage of the power source is correct before connecting the equipment to the power disconnect.
  • Page 50 Chapter 2: Begin Installation 2. Si l'équipement n'est pas utilisé pendant une longue période, retirez-le de la source d'alimentation pour éviter tout dommage dû à une surtension transitoire. 3. Pour une utilisation dans des environnements de degré de pollution 2 et à...
  • Page 51 IS Series Industrial Ethernet Layer 2 Switch Installation Guide 6. Utilisez uniquement des émetteurs-récepteurs à fibre optique certifiés EN 60825-1 dont la température de fonctionnement maximale est égale ou supérieure à 75° C. 7. Cet appareil ne doit pas être utilisé dans des endroits où se trouvent des enfants.
  • Page 52: Safety Statements

    Chapter 2: Begin Installation Safety Statements The following safety statements apply to the IS Series switch products: Warning Class 1 Laser product.  L1 Warning Do not stare into the laser beam.  L2 Warning Do not look directly at the fiber optic ends or inspect the cable ends with an optical lens.
  • Page 53 IS Series Industrial Ethernet Layer 2 Switch Installation Guide Note All Countries: Install product in accordance with local and National Electrical Codes.  E8 Warning Only trained and qualified personnel are allowed to install or replace this equipment.  E14 Caution Air flow around the unit and through the cooling fins must not be restricted.
  • Page 54 Note The equipment meets EN61000-4-5 Class 3 on the DC inputs and Ethernet ports. Warning Allied Telesis does not warrant against lightning or power surges causing damage the device. Such damage will be the responsibility of the equipment owner.
  • Page 55: Safety Precautions With Electricity

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Safety Precautions With Electricity Please review the following additional safety guidelines before beginning the installation procedure. Disconnect all power by turning off the circuit breakers before  installing or removing the device or when working with the power supplies.
  • Page 56: Review Site Requirements

    Chapter 2: Begin Installation Review Site Requirements Please observe the following requirements and guidelines when choosing a site for the IS Series switch: You can install the switch on a concrete or masonry wall or  industrial panel or DIN 35x7.5mm rail. The DC power source should be located near the device and be ...
  • Page 57: Table 8: Ground Resistivity Recommendations

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide The switch and DC power source should be installed close to each  other so that the DC power cables are kept as short as possible to minimize voltage loss. The switch and power supply should be properly connected to a ...
  • Page 58: Verify Package Contents

    Figure 15 identifies the pre-installed components on the front panel of the switch. Eleven dust covers on the twisted- pair ports and Console port Two dust covers on the SFP slots Figure 15. Pre-installed Components on the AT-IS230-10GP Front Panel...
  • Page 59: Figure 16: Pre-Installed Components On The At-Is130-6Gp Front Panel

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Figure 16 identifies the pre-installed components on the front panel of the switch. One dust covers on the SFP slots Five dust covers on the twisted-pair ports and Console port Figure 16. Pre-installed Components on the AT-IS130-6GP Front Panel...
  • Page 60: Figure 17: Pre-Installed Components On The Top Panel

    Chapter 2: Begin Installation The Power/Alarm connector and the grounding screw locations are identified in Figure 17. One M4x8 Phillips-head grounding screw with star washer One 6-pin connector on the DC power PWR 1, PWR 2 and P-Fail connector Figure 17. Pre-installed Components on the Top Panel Figure 18 identifies the pre-installed DIN rail bracket on the back panel.
  • Page 61: Figure 19: At-Is230-10Gp Accessory Kit Components

    One 2 m (6.6 ft) local management cable with RJ-45 (8P8C) and DB-9 (D-sub 9-pin) connectors Figure 19. AT-IS230-10GP Accessory Kit Components Figure 19 lists the items included in the accessory kit that comes with the switch. Two wall brackets...
  • Page 62 Chapter 2: Begin Installation...
  • Page 63: Chapter 3: Install The Switch

    Chapter 3 Install the Switch The procedures in this chapter are listed here: “DIN Rail Installation” on page 64  “Install Switch On Concrete or Masonry Wall or Industrial Panel” on  page 66...
  • Page 64: Din Rail Installation

    Note Figure 21, Figure 22, and Figure 23 below illustrate the AT-IS230-10GP switch, but also apply to the AT-IS130-6GP switch. Figure 21 shows the proper orientation of the switch on a DIN rail. Do not install the switch horizontally or upside-down.
  • Page 65: Figure 22: Install Top Slot Of Din Rail Bracket Onto Din Rail

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide TOP Slot in DIN rail bracket Top edge of DIN rail Figure 22. Install Top Slot of DIN Rail Bracket onto DIN Rail 2. Press down against the spring within the bracket on the top back edge of the switch until you the bottom edge of the front faceplate of the switch can be pushed back and under the bottom edge of the DIN rail.
  • Page 66: Install Switch On Concrete Or Masonry Wall Or Industrial Panel

    Chapter 3: Install the Switch Install Switch On Concrete or Masonry Wall or Industrial Panel This section contains instructions on how to install the switch on a concrete or masonry wall or industrial panel. Warning The device is heavy. Always ask for assistance before moving or lifting it to avoid injuring yourself or damaging the equipment.
  • Page 67: Figure 24: Remove Din Rail Mounting Bracket

    AT-IS130-6GP Figure 24. Remove Din Rail Mounting Bracket 3. On the AT-IS130-6GP top and bottom panel and the AT-IS230-10GP back panel, align and install the two wall mounting brackets (provided) with the bracket mounting screws (provided). Refer to Figure 25.
  • Page 68: Figure 26: Mark Wall Bracket Hole Locations

    Chapter 3: Install the Switch 4. Hold the switch on the concrete or masonry wall or industrial panel at the selected location for the device while you use a pencil or pen to mark the locations of the four screw holes in the two wall brackets. Refer to Figure 26.
  • Page 69: Figure 27: Install Switch Using Wall Brackets

    – Prior to drilling, set the drill to hammer and rotation mode. The modes break up the concrete and clean out the hole. – Allied Telesis recommends cleaning out the holes with a brush or compressed air. b. Insert anchors (not provided) into the four holes.
  • Page 70 Chapter 3: Install the Switch...
  • Page 71: Chapter 4: Install Twisted-Pair Ports Cables

    Chapter 4 Install Twisted-Pair Ports Cables This chapter contains the following procedures: “Twisted-Pair Port Cables” on page 72  “Install SFP Transceivers and Fiber Cables” on page 73 ...
  • Page 72: Twisted-Pair Port Cables

    The Twisted-Pair Standard Cable Requirements for non-PoE and  PoE wiring are given in Table 17 on page 102 and Table 18 on page 103. Note The default setting for the AT-IS230-10GP switch PoE ports is enabled. The AT-IS130-6GP switch PoE ports are always enabled.
  • Page 73: Install Sfp Transceivers And Fiber Cables

     E86 The illustrations in the following procedure show a transceiver with a duplex LC connector installed in a AT-IS230-10GP switch. The connectors on your transceivers may be different. To install SFP transceivers in the chassis, perform the following procedure: 1.
  • Page 74: Figure 29: Install Sfp Transceiver

    Figure 29. Install SFP Transceiver Note If you are ready to attach the fiber optic cable to the transceiver, continue with the next step. Otherwise for the AT-IS230-10GP switch, repeat steps 1 to 3 to install the other transceiver in the switch.
  • Page 75: Figure 31: Connect Fiber Optic Cable To Sfp Transceiver

    This space is reserv Figure 31. Connect Fiber Optic Cable To SFP Transceiver 6. For the AT-IS230-10GP switch, repeat this procedure to install and connect the cable to the other SFP transceiver if required. 7. Go to Chapter 5, “Power On Switch” on page 77.
  • Page 76 Chapter 4: Install Twisted-Pair Ports Cables...
  • Page 77: Chapter 5: Power On Switch

    Chapter 5 Power On Switch This chapter contains the following procedures: “Connect Ground Wire” on page 78  “Power/Alarm Connector Cables” on page 81  “Apply Power To Switch” on page 86  “Start Management Session” on page 87 ...
  • Page 78: Connect Ground Wire

    Chapter 5: Power On Switch Connect Ground Wire Here are the guidelines for the ground wire: Warning Take into consideration the following guidelines before wiring the device. Attention Tenez compte des directives suivantes avant de câbler l'appareil. The terminal block (CN1) is suitable for 12-18 AWG (7A). Torque ...
  • Page 79: Figure 33: Loosen Grounding Screw

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide 2. Loosen the grounding screw several turns with a #2 Phillips-head screwdriver. Refer to Figure 33 on page 79. Figure 33. Loosen Grounding Screw 3. Wrap the grounding wire clockwise around the base of the grounding screw beneath the star-lock washer provided.
  • Page 80 Chapter 5: Power On Switch 5. Connect the other end of the ground wire to an earth-ground point at the installation site. 6. Go to “Power/Alarm Connector Cables” on page 81.
  • Page 81: Power/Alarm Connector Cables

    #1 flat-head screwdriver  Wire insulation stripper  Take into consideration the following guidelines before wiring the device: The AT-IS230-10GP switch support dual +24-48VDC power  inputs. The AT-IS130-6GP switch support dual +48-54VDC power inputs.  Tighten wire-clamps to a torque value 7 lb-in. to prevent the DC ...
  • Page 82: Figure 37: Wrap Wire Strands

    Allied Telesis recommends that you also tin the wires with solder as added protection against loose strands. This guide does not provide instructions on how to tin wires. 3. On the AT-IS230-10GP switch, loosen the two fastening screws on the sides of the Power/Alarm connector. Note The AT-IS130-6GP switch Power/Alarm connector does not have connector fastening screws.
  • Page 83: Figure 39: Loosen Power/Alarm Connector Wire Retaining Screws

    - pins 3 and 4. There is no polarity for the alarm wires. Refer to Figure 40. PWR V2+/- PFail PWR V1+/- AT-IS230-10GP PWR V1+/- PFail PWR V2+/- AT-IS130-6GP Figure 40. Insert Power Supply and Alarm Wires into Power/Alarm Connector 7.
  • Page 84: Figure 41: Verify Wire Installation

    Chapter 5: Power On Switch Warning Check to see if there are any exposed copper strands coming from the installed wires. When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block. Any exposed wiring can conduct harmful levels of electricity to persons touching the wires.
  • Page 85: Figure 43: Insert The Power/Alarm Connector

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Figure 43. Insert the Power/Alarm Connector 14. On the AT-IS230-10GP switch, tighten the two connector fastening screws on the ends of the power/alarm connector to the chassis as shown in Figure 44.
  • Page 86: Apply Power To Switch

    The PoE LEDs should be solid green on ports that are connected  to PoE or PoE+ devices. The PoE LEDs are identified in Figure 13 on page 43. If you have a AT-IS230-10GP switch, go to “Start Management Session” on page 87.
  • Page 87: Start Management Session

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Start Management Session The initial management session for the AT-IS230-10GP switch may be conducted via a local session by connecting to the Console port or a over a network connection on any of the Ethernet ports of the switch.
  • Page 88: Network Management Session

    This prompt represents the User Exec mode in the command line interface in the switch. Refer to the AT-IS230-10GP switch Reference Guide for the available CLI commands. Network This section contains the procedure for starting the AT-IS230-10GP management session via a network connection.
  • Page 89 IS Series Industrial Ethernet Layer 2 Switch Installation Guide The login screen displays. c. Enter the default username (manager) and password (friend). Note The user name and password are case sensitive. d. Click OK on the login screen to log in. The main web interface window is displayed.
  • Page 90 Chapter 5: Power On Switch...
  • Page 91: Chapter 6: Troubleshooting

    “PWR 1 and PWR 2 LEDs” on page 92  “Twisted-Pair Ports” on page 93  “SFP Slots” on page 94  “Power Over Ethernet” on page 95  Note For further assistance, please contact Allied Telesis Technical Support at www.alliedtelesis.com/support.
  • Page 92: Pwr 1 And Pwr 2 Leds

    Chapter 6: Troubleshooting PWR 1 and PWR 2 LEDs Problem: A DC power supply is connected to the switch, but the corresponding PWR 1 or PWR 2 LED on the front panel is off. Solutions: The unit is not receiving power from the power supply or the power is outside the operating range of the switch.
  • Page 93: Twisted-Pair Ports

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Twisted-Pair Ports Problem: A twisted-pair port on the switch is connected to a network device but the port’s LINK/ACT LED is off. Solutions: The port is unable to establish a link to a network device. Try the following: Verify that the port is connected to the correct twisted-pair cable.
  • Page 94: Sfp Slots

    If the port is able to establish a link, then the problem is with the cable or with the other network device. On the AT-IS230-10GP switch, use the switch’s management  software to verify that the port is enabled.
  • Page 95: Power Over Ethernet

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Power Over Ethernet Problem: The AT-IS230-10GP switch is not providing power to a PoE or PoE+ device. Solutions: Try the following: Check that the device’s power requirements do not exceed those ...
  • Page 96 Chapter 6: Troubleshooting...
  • Page 97: Appendix A: Technical Specifications

    Appendix A Technical Specifications This appendix contains the following sections: “Physical Specifications” on page 98  “Environmental Specifications” on page 99  “Power Specifications” on page 100  “Certifications” on page 101  “RJ-45 Twisted-Pair Ethernet Port Pinouts” on page 104 ...
  • Page 98: Physical Specifications

    Physical Specifications Dimensions Table 9 lists the dimensions of the products. Table 9. Product Dimensions AT-IS230-10GP 74 x 105 x 152 mm (W x D x H) switch (2.91 x 4.13 x 5.98 in.) AT-IS130-6GP 30 x 95 x 140 mm (W x D x H) switch (1.18 x 3.74 x 5.51 in.)
  • Page 99: Environmental Specifications

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Environmental Specifications Table 12 lists the IS Series environmental specifications. Table 12. Environmental Specifications ° ° ° ° Operating Temperature Range C to 75 C (-40 F to 167 ° ° °...
  • Page 100: Power Specifications

    2W (Full port load w/o PoE) Table 14 lists the external power supply DC output specifications. Table 14. External Power Supply DC Output Specifications AT-IS230-10GP PS DC Output 24 - 48VDC, 7.0A AT-IS130-6GP PS DC Output 48VDC, 2.5A OR 54V, 2A °...
  • Page 101: Certifications

    Certifications The regulatory approvals of the product are listed in Table 16. Table 16. Regulatory Approvals Safety IEC/EN/UL60950-1 (only AT-IS230-10GP) CAN/CSA-C22.2 No.60950-1 (only AT-IS230-10GP) UL61010-2-201 (only AT-IS230-10GP) CAN/CSA-C22.2 No.61010-2-201 (only AT-IS230-10GP) EN 61010-2-201 (only AT-IS230-10GP) IEC/EN/UL 62368-1 (only AT-IS130-6GP) CSA C22.2 No.62368-1 (only AT-IS130-6GP)
  • Page 102: Standard Cable Requirements

    Standard Cable Requirements The standard cable requirements for the ports on the IS Series switches are listed in Table 17. Table 17. Twisted-Pair Standard Cable Requirements Cable Type 10Mbps 100Mbps 1000Mbps Standard TIA/EIA 568-B- compliant Category 3 shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz.
  • Page 103: Cabling For Poe Devices

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Cabling for PoE Devices The cable requirements for the PoE twisted-pair ports on the IS Series switches for powered devices are given in Table 18. For cable requirements for ports connected to non-PoE devices, refer to Table 17 on page 102.
  • Page 104: Rj-45 Twisted-Pair Ethernet Port Pinouts

    RJ-45 Twisted-Pair Ethernet Port Pinouts Figure 45 identifies pin 1 on an RJ-45 twisted-pair port. Figure 45. RJ-45 Port Pin Layout (Front View) Table 19 lists the pin signals for a port when it is operating at 10 or 100 Mbps.
  • Page 105: Table 20: Pin Signals For 1000 Mbps

    IS Series Industrial Ethernet Layer 2 Switch Installation Guide Table 20 lists the pin signals for a port when it operating at 1000 Mbps. Table 20. Pin Signals for 1000 Mbps Pinout Pair Pair 1 + Pair 1 - Pair 2 + Pair 3 + Pair 3 - Pair 2 -...
  • Page 106: Rj-45 Style Serial Console Port Pinouts

    RJ-45 Style Serial Console Port Pinouts Table 21 lists the AT-IS230-10GP Console port RJ-45 pin signals. Table 21. Console Port Pin Signals Signal Open Open Transmit Data Ground Ground Receive Data Open Ground...
  • Page 107: Power/Alarm Connectors

    P-Fail Alarm fault V2 + PWR Supply 2 V+ V2 - PWR Supply 2 V- AT-IS230-10GP AT-IS130-6GP Figure 46. IS Series Power/Alarm Connectors Note For details of the power supply requirements, refer to “Power Supplies” on page 45. P-Fail Alarm...

This manual is also suitable for:

Is seriesAt-is130-6gpIs230-10gpIs130-6gp

Table of Contents