IEFB-FB-PG-T10-LCD
* product series image displayed

IEFB-FB-PG-T10-LCD | Dwyer Instruments | Flow

INSRT ELEMAG ENERGY METER, HIGH ACC, 1" BSPT, 4" PIPE, 10 FT TEMP SENSOR , LCD DISP

Brand:Dwyer Instruments

MPN:IEFB-FB-PG-T10-LCD

SKU:IEFB-FB-PG-T10-LCD

List Price:

$11,023.00

Today's Price:

$5,731.96



Availability: Usually Ships in Less Than 10 Business Days
Available Inventory
Lead times are estimates based on our Memphis location and subject to change without notice based on customer demand.

Need more?
Just order your desired quantity and we'll ship the available inventory immediately while we source the remaining quantity to get you all the products you need as soon as possible.

We can also reserve the available inventory and ship once we acquire the remaining quantity from the supplier. Just choose "Ship Complete" at checkout.

product specifications

Supply Voltage

24 VDC

Type

Insertion Meter

Pipe Size

4 in

Max Pressure

400 PSI

product series specifications

    Service:
  • †Compatible clean or dirty non-coating, conductive liquids
    Range:
  • †0 to 20 ft/s (0 to 6 m/s).*
    Wetted Materials:
  • †Body shaft/fitting: 316 SS; Electrodes: 316 SS; Electrode cap: Polymer/polystyrene; O-ring:† †Silicone. Thermowells: 316 SS
    BTU Accuracy per EN1434/ASTM E3137/CSA C900.1-13:
  • †High Accuracy Units: Class 2 for 2 to 20 ft/s (0.6 to 6 m/s)**; Standard Accuracy Units: Class 3 for† †6.5 to 20 ft/s (2 to 6 m/s)**
    Flow Sensor†Accuracy:
  • †High Accuracy Units: ±0.5% of reading at calibrated velocity, ±1% of reading from 2 to 20 ft/s (0.6 to† †6 m/s) ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s); Standard Accuracy Units: ±1% FS
    Temperature Accuracy:
  • †Class B ±(0.30 + 0.005*t)°C per EN60751
    Differential†Temperature Accuracy†:
  • †Et = ±(0.5 +3*ŒîŒòmin/ŒîŒò) % per EN1434
    Calculator Accuracy:
  • †Ec = ±(0.5 +ŒîŒòmin/ŒîŒò) % per EN1434
    RTD Accuracy:
  • †Accuracy class: Class B ±(0.30 + 0.005*t)°C per EN60751 Accuracy: Et = ±(0.5 +3*ŒîŒòmin/ŒîŒò) %† †per EN1434†
    Temperature†Compensation†:
  • †140 to 220°F (60 to 104.4°C) < 2% error over ±30°F (-1.1 °C) change, 40 to 70°F (4.4 to 21.1°C)†

    † <2% error over ±10°F (-12.2°C) change

    Temperature Limits:
  • †Ambient: -20 to 160°F (-29 to 71°C);** Process: 32 to 250°F (0 to 121°C);†

    †Storage: -40 to 185°F (-40 to 85°C)†

    Process Connection:
  • †Flowmeter: 1Àù NPT or BSPT with accessory full port ball valve options; Thermowell: (2) 1/2Àù NPT or† †BSPT thermowell with full port ball valve option.
    Pressure Limit:
  • †400 psi (27.6 bar) @ 100°F (37.8°C)
    Pressure Drop:
  • †< 0.1 psi at 12 ft/s in 4Àù (<0.01 bar at 3.7 m/s in 100 mm) and larger pipe
    Outputs:
  • †(1) Analog: 4-20 mA, 0-5 V, 0-10 V or 2-10 V (display selectable); (1) Pulse/Frequency: 0-15 V† †peak pulse, 0-500 Hz or scalable pulse output (display selectable); (2) Alarm: Empty pipe detection† †or minimum/maximum velocity, (display selectable) & Reverse flow output indication
    Power Requirements:
  • †12-42 VDC, .25 A @ 24 VDC; 12-36 VAC
    Electrical Connection:
  • †Removable terminal blocks, (2) model selectable 1/2Àù female NPT conduit connection, (2) PG 16† †gland or (2) PG 16 gland with 10 ft (3 m) 9 conductor 22 AWG plenum rated cables, accessory† †cable lengths up to 200 ft (61 m) optional
    Display (-LCD option):
  • †2 x 2Àù (50 x 50 mm) graphic LCD with backlight
    Conductivity:
  • †>20 micro siemens
    Enclosure Material:
  • †Powder-coated die-cast aluminum
    Enclosure Ratings:
  • †NEMA 6P (IP68) (Non display models); NEMA 4X (IP66) (-LCD option)
    Approvals:
  • †BTL
    Notes::
  • †*For max flowrates >10 ft/s (3 m/s) order option -CC.

    †**Verified at standard temperature 73.4°F (23°C) refer to listed standards for detailed accuracy† † †formulations.

product series features

  • Flexible, field configurable setup displays (LCD integral option or remote accessory A-IEF-DSP) accommodate a variety application configurations. Application information is display selectable and includes pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication, outputs, damping, and calibration factor
  • High-performance accuracy is maintained through changes in temperature, density and/or viscosity
  • The Setup Wizard and installation tool are simple to use, providing quick and precise installation
  • Accessory setup kit A-IEF-KIT comes with a thickness gauge and measuring tape to ensure exact installation depth
  • The meter has no moving parts and electrodes that discourage fouling, which gives the meter a long lifecycle and minimizes the need for maintenance
  • Hot-tap isolation valve accessories allow for easy installation and removal in operational systems without system downtime

more information & related documents

Series Description

The Dwyer IEFB Series is a field-adjustable, insertion thermal energy meter that uses electromagnetic technology to accurately and reliably measure fluid velocity and energy consumption. The flowmeter is simple to install and is adjustable to fit pipe sizes from 4 to 10Ë (100 to 900 mm). The Dwyer IEFB Series incorporates a temperature meter and a calculator into a single unit. The LCD display provides clear readings of the meter's values, including temperature and energy consumption, making it ideal for installation on&nbsp;chillers, boilers, and other heating and cooling applications. In addition, it offers several output options, including selectable BACnet MS/TP or Modbus® RTU communications protocol over two-wire RS-485 and standard analog, frequency, and alarm outputs. Furthermore, the superior performance of the IEFB keeps annual operating costs at a minimum thanks to its combination of high measuring accuracy and long lifetime.

Kele Description

INSRT ELEMAG ENERGY METER, HIGH ACC, 1" BSPT, 4" PIPE, 10 FT TEMP SENSOR , LCD DISP