Service Center 800-441-8246
  1. Products
  2. Sensors
  3. Magnetic sensors
  4. All magnetic sensors
  5. M9H212

Position sensor

M9H212

M9B3002-BPKG/B/AM/0,5M/ZH/US

Position sensor

M9H212

M9B3002-BPKG/B/AM/0,5M/ZH/US

  • Pressure-resistant up to 350 bar
  • Designed for use in plunger detection
  • Compact and robust stainless steel housing
  • Spanner flat for easy mounting
  • High shock and vibration resistance for mobile applications
  • ce
  • ukca
  • e1r
Product characteristics
Electrical design PNP
Output function normally open
Dimensions [mm] M11 x 1 / L = 56.5
Application
Application lubricant distributor with plunger
Media Detects ferrous metals
Pressure rating [bar] 350
Electrical data
Operating voltage [V] 10...60 DC
Rated insulation voltage [V] 60
Current consumption [mA] < 20
Protection class III
Reverse polarity protection yes
Max. power-on delay time [ms] 300
Outputs
Electrical design PNP
Output function normally open
Max. voltage drop switching output DC [V] 2.5
Max. leakage current [mA] 0.1
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 50
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Monitoring range
Real sensing range Sr [mm] 2 ± 10 %
Operating distance [mm] 0...1.62
Accuracy / deviations
Hysteresis [% of Sr] 3...15
Operating conditions
Ambient temperature [°C] -25...70
Note on ambient temperature
Operating voltage: <60V
Ambient temperature [°C] -40...85
Note on ambient temperature
Operating voltage: <45V
for flexibly laid cable: -25 °C
firmly laid cable: -40 °C
Protection IP 65; IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m 80...2000 MHz
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V 0,15...80 MHz
EN 61000-4-8 30 A/m
EN 55011 class B
Noise emission and noise interference according to the automotive directive 95/54/EC E1 type approval
conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4)
pulse 1 2a 2b 3a 3b 4
Severity level III III III III III III
Failure criterion C B C A A C
Vibration resistance
EN 60068-2-6 Fc 50x 20 g / 10...3000 Hz -20 °C
EN 60068-2-6 Fc 50x 20 g / 10...3000 Hz +50 °C
Shock resistance
EN 60068-2-27 Ea 3 x 100 g 11 ms / -25 °C
EN 60068-2-27 Ea 3 x 100 g 11 ms / +85 °C
Continuous shock resistance
EN 60068-2-27 Ea 4000 x 40 g 6 ms / -20 °C / 50 °C
MTTF [years] 1181
Mechanical data
Weight [g] 78.9
Mounting flush mountable
Dimensions [mm] M11 x 1 / L = 56.5
Thread designation M11 x 1
Material sensing face: stainless steel (1.4404 / 316L); housing: stainless steel (1.4404 / 316L); end cap: TPU (urethane)
Tightening torque [Nm] < 18
Process connection threaded connection M11 x 1 external thread
Displays / operating elements
Display
Switching status LED, yellow
Remarks
Pack quantity 1 pcs.
Electrical connection
Cable: 0.5 m, PUR
Connector: 1 x M12; coding: A