STORAGE CONTROLLERS
COMMON CABLES
ADAPTER CARDS
SYSTEM CABINET AND POWER
SHELF ENCLOSURES
DISK DRIVES
U01
U02
U03
U04
U05
U06
U07
U08
U09
U10
U11
U12
U13
U14
U15
U16
U17
U18
U19
U20
U21
U22
U23
U24
U25
U26
U27
U28
U29
U30
U31
U32
U33
U34
U35
U36
U37
U38
U39
U40
U41
U42
Fabric-Attached Storage (FAS) and V-Series Controllers
Model FAS/V6280 FAS/V6240 FAS/V6210 FAS/V3270 FAS/V3250 FAS/V32401FAS/V32201FAS/V3210 FAS2240-4 FAS2240-2 FAS2220
Front View
Max Capacity2
(7.3.x / 8.0.x / 8.1.x)
- / 4320TB3 /
4320TB3
- / 4320TB3 /
4320TB3
- / 3600TB3 /
3600TB3
960TB / 2880TB3
/ 2880TB3- / - / 2160TB3 600TB / 1800TB3
/ 1800TB3- / - / 1440TB3 240TB / 720TB3
/ 720TB3- / - / 432TB - / - / 374TB - / - / 180TB
Max Aggregate4
(7.3.x / 8.0.x / 8.1.x) - / 100TB / 162TB - / 100TB / 162TB - / 70TB / 162TB 16TB / 70TB /
105TB - / - / 105TB 16TB / 50TB /
90TB - / - / 90TB 16TB / 50TB / 75TB - / - / 60TB - / - / 60TB - / - / 60TB
Max FlexVol Size
(7.3.x / 8.0.x / 8.1.x) - / 100TB / 100TB - / 100TB / 100TB - / 70TB / 70TB 16TB / 70TB / 70TB - / - / 70TB 16TB / 50TB / 50TB - / - / 60TB 16TB / 50TB / 50TB - / - / 60TB - / - / 60TB - / - / 60TB
Max Shelves
(DS4486 / DS2246 /
DS4243 / DS14)
30 / 60 / 60 / 84 30 / 60 / 60 / 84 25 / 50 / 50 / 72 20 / 40 / 40 / 68 15 / 30 / 30 / 51 12.5 / 25 / 25 / 42 10 / 20 / 20 / 34 - / 10 / 10 / 17 - / 5 / 5 / 6 - / 5 / 5 / 6 - / 2 / 2 / -
Max Drive Quantity 1440 1440 1200 960 720 600 480 240 144
(24 Int + 120 Ext)
144
(24 Int + 120 Ext)
60
(12 Int + 48 Ext)
V-Series
Specifi cations
Max Backend
LUNs 1440 1440 1200 960 720 600 480 1009No V-Series Models
V-Series
Supported
Arrays
No V-Series Models
Environmental
HA Pair / Single Controller
Height
(HA / Single) 12U / 6U 12U / 6U 6U / 6U 6U / 3U 6U / 3U 6U / 3U 6U / 3U 3U / 3U 4U / 4U 2U / 2U 2U / 2U
Weight
(HA / Single)
251.4 (114 kg)
125.7 lbs (57 kg)
251.4 (114 kg)
125.7 lbs (57 kg)
130.1 lb. (59 kg)
99.2 lb. (45 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
79.5 lb. (36.1 kg)
67.3 lb. (30.5 kg)
107.1 lbs (48.7 kg)
102 lbs (46.4 kg)
55.4 lbs (25.2 kg)
50.4 lbs (22.9 kg)
62.4 lbs (28.3 kg)
57.8 lbs (26.2 kg)
AC Power5
(HA / Single)
19.2A / 9.6A @100V
9.4A / 4.7A @200V
18.6A / 9.3A @100V
9A / 4.5A @200V
- / 5A @100V
4.8A / 2.5A @200V
7.28A / 5.47A @100V
3.58A / 2.73A @200V
10.94A / 5.47A @100V
5.46A / 2.73A @200V
6.37A / 5.01A @100V
3.15A / 2.5A @200V
6.37A / 3.71A @100V
3.15A / 1.96A @200V
6.27A / 4.22A @100V
3.11A / 2.11A @200V
5.97A / 5.36A @100V
3.01A / 2.70A @200V
4.45A / 3.92A @100V
2.23A / 1.92A @200V
4.32A / 5.31A @100V
2.59A / 2.14A @200V
BTU/hr6
(HA / Single)
6486 / 3243 @100V
6212 / 3106 @200V
6280 / 3140 @100V
5974 / 2987 @200V
- / 1673 @100V
3174 / 1639 @200V
2485 / 1867 @100V
2413 / 1820 @200V
3734 / 1867 @100V
3640 / 1820 @200V
2168 / 1707 @100V
2116 / 1632 @200V
2168 / 1256 @100V
2116 / 1229 @200V
2137 / 1437 @100V
2089 / 1403 @200V
2031 / 1820 @100V
1775 / 1983 @200V
1536 / 1332 @100V
1434 / 1294 @200V
1806 / 1471 @100V
1751 / 1444 @200V
Platform Specifi cations
HA Pair / Single Controller
Processor
(HA / Single)
4 / 2
64-bit six-core
4 / 2
64-bit quad-core
4 / 2
64-bit quad-core
4 / 2
64-bit dual-core
4 / 2
64-bit quad-core
2 / 1
64-bit quad-core
2 / 1
64-bit quad-core
2 / 1
64-bit dual-core
2 / 1
64-bit dual-core HT
2 / 1
64-bit dual-core HT
2 / 1
64-bit dual-core HT
Memory
(HA / Single) 192GB / 96GB 96GB / 48GB 48GB / 24GB 40GB / 20GB10 40GB / 20GB10 16GB / 8GB10 24GB / 12GB10 10GB / 4GB10 12GB / 6GB10 12GB / 6GB10 12GB / 6GB10
NVRAM
(HA / Single) 8GB / 4GB 8GB / 4GB 8GB / 4GB 4GB / 2GB
NVMEM
4GB / 2GB
NVMEM
2GB / 1GB
NVMEM
3.2GB / 1.6GB
NVMEM
1GB / 512MB
NVMEM
1.5GB / 768MB
NVMEM
1.5GB / 768MB
NVMEM
1.5GB / 768MB
NVMEM
Exp Slots
(HA / Single) 24 / 12 PCIe 24 / 12 PCIe 8 / 4 PCIe 12 / 6 PCIe 12 / 6 PCIe 12 / 6 PCIe 12 / 6 PCIe 4 / 2 PCIe 2 / 1
mezzanine
2 / 1
mezzanine -
Ethernet
(HA / Single)
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
4 / 2
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
8 / 4 GbE RJ45
0-4 / 0-2 10GbE
8 / 4 GbE RJ45
0-4 / 0-2 10GbE 8 / 4 GbE RJ45
FC Ports
(HA / Single)
8-32 / 4-16
8Gb SFP+7
8-32 / 4-16
8Gb SFP+7
8-16 / 4-8
8Gb SFP+7
4 / 2
4Gb SFP
4 / 2
4Gb SFP
4 / 2
4Gb SFP
4 / 2
4Gb SFP
4 / 2
4Gb SFP
0-4 / 0-2
8Gb SFP+
0-4 / 0-2
8Gb SFP+ -
SAS Ports
(HA / Single)
0-24 / 0-12
6Gb QSFP8
0-24 / 0-12
6Gb QSFP8
0-8 / 0-4
6Gb QSFP8
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
Data ONTAP®
(Min Release) 8.0.1, 8.1 8.0.1, 8.1 8.0.1, 8.1 7.3.5, 8.0.1, 8.1 8.1.2 7.3.5, 8.0.1, 8.1 8.1.2 7.3.5, 8.0.1, 8.1 8.1 8.1 8.1.1
EMC
· VNX
· CX3,CX4
· VMAX
· DMX4
HP
· EVA x400, x100
· P6x00, P6x50
· XP24K, XP20K
3PAR
· P10000
· T400, T800
· F200, F400
HDS
· VSP
· AMS
· USP-V
· HUS
IBM
· DS8700, DS8800
· DS5xx0
· DS4700, DS4800
· XIV Gen2 & Gen3
Fujitsu
· DX8000
· DX4x0
· DX8700 S2
· DX4x0 S2
Refer to the NetApp Interoperability Matrix at
http://support.netapp.com/matrix for the
latest back-end storage array support information.
Data ONTAP Edge
Operating
System
CIFS
De-Dupe
FAS
FlexClone
FlexCache
FlexVol
iSCSI
NFS
ONTAP-V
SnapShot
SnapMirror
Snap Restore
SnapVault
Primary
SnapVault
Secondary
V-Series
5TB
Capacity
Data ONTAP
Edge
Data ONTAP
Edge-T
Cluster-Mode Switches
Model CN1610 CN1601
Supported
Modes Cluster Cluster
Management
Environmental HA Pair / Single Controller
Rack Units 1U 1U
Dimensions
H: 1.69 in (4.3 cm)
W: 17.5 in (44.5 cm)
D: 20 in. (50.8 cm)
H: 1.69 in (4.3 cm)
W: 17.5 in (44.5 cm)
D: 20 in. (50.8 cm)
Weight 22.5 lbs (10.2 kg) 12 lbs (5.45 kg)
Amps
(Worst-case)
1.28A @100-120V
.82A @200-240V
0.58A @100-120V
0.37A @200-240V
Watts
(Worst-case)
128W @100-120V
118W @200-240V
33W @100-120V
33W @200-240V
BTU/hr
(Worst-case)
403 @100-120V
403 @200-240V
113 @100-120V
113 @100-120V
Platform
Specifi cations
Ethernet 16 10GbE SFP+ 16 GbE RJ45
Data ONTAP®
(Min Release) 8.1.1 8.1.1
Optical Module Support for Onboard Ports
Model
FAS/V6280
FAS/V6240
FAS/V6210
FAS/V3270
FAS/V3250
FAS/V3240
FAS/V3220
FAS/V3210
FAS2240-4
FAS2240-2
CN1610
Eth-
ernet
X6589-R6
10Gb SFP+
Fibre
Channel
X6588-R6
8Gb SFP+
X6539-R6
4Gb SFP
HA
X1956-R6
QSFP
X6589-R6
10Gb SFP+
Ethernet Cables and Connectors
Part Number Begin End Length Notes
X6560-R6 RJ45 RJ45 0.5m CAT6
X6561-R6 RJ45 RJ45 2m CAT6
X6562-R6 RJ45 RJ45 5m CAT6
X6577-R6 RJ45 RJ45 30m CAT6
X6563-R6 SFP+ LC - X1107A Op Module
X6569-R6 SFP+ LC - X1117A Op Module
X6589-R6 SFP+ LC - FAS/V6200 10GbE Op Mod
X6592-R616 RJ45 RJ45 10m CAT6 - ACP
X6593-R616 RJ45 RJ45 20m CAT6 - ACP
X-SFP-H10GB-CU1M-R6 SFP+ SFP+ 1m Cisco Twinax
X-SFP-H10GB-CU3M-R6 SFP+ SFP+ 3m Cisco Twinax
X-SFP-H10GB-CU5M-R6 5m Cisco Twinax
X-TWX-0101-R6 SFP+ SFP+ 1m Brocade Twinax
X-TWX-0301-R6 SFP+ SFP+ 3m Brocade Twinax
X-TWX-0501-R6 SFP+ SFP+ 5m Brocade Twinax
HA Pair, Cluster Interconnect Cables and Connectors
Part Number Begin End Length Notes
X6558-R6 QSFP QSFP 2m FAS/V6200 NVRAM8 HA
X6559-R6 QSFP QSFP 5m FAS/V6200 NVRAM8 HA
X1956-R6 QSFP MTP - Op Mod FAS/V6200 NVRAM8
X1945A-R6 MTP MTP 5m -
X1946A-R6 MTP MTP 30m -
X1951A-R6 MTP SC 30m 4X to 1X path
X1952A-R6 MTP ST 30m 4X to 1X path
X1953A-R6 MTP LC 30m 4X to 1X path
X1954A-R6 MTP FC 30m 4X to 1X path
X1955A-R6 MTP MT-RJ 30m 4X to 1X path
X-SFP-H10GB-CU1M-R6 SFP+ SFP+ 1m FAS/V3200 HA
X-SFP-H10GB-CU3M-R6 SFP+ SFP+ 3m FAS/V3200 HA
X-SFP-H10GB-CU5M-R6 SFP+ SFP+ 5m FAS/V3200 HA
X6589-R6 SFP+ LC - Op Module FAS/V3200 HA
X6566-3-R6 QSFP QSFP 3m 10Gbe
X6566-2-R6 QSFP QSFP 2m 10Gbe
X6566-5-R6 QSFP QSFP 5m 10Gbe
X6566-05-R6 QSFP QSFP 0.5m 10Gbe
Fibre Channel Cable and Connectors
Part Number Begin End Length Notes
X6529-R6 SFP LC - Op Module (2Gb)
X6539-R6 SFP LC - Op Module (4Gb) FAS/V6080,
6040, 3200, 3100, and 2050
X6588-R6 SFP+ LC - FAS/V6200 and FAS2240
Op Module (8Gb)
X6530-R6 SFP SFP 0.5m 4Gb Shelf/Tape only
X6532-R6 SFP SFP 3m 2Gb Shelf/Tape only
X6556-R6 SFP SFP 5m 4Gb support
X6538-R6 SFP DB9 3m -
X6531-R6 SFP HSSDC2 0.5m -
X6533-R6 SFP HSSDC2 3m -
SCSI \ SAS Cables and Connectors
Part Number Begin End Length Notes
X6513-R6 HD-68 VHDCI 2m -
X6557-R6 QSFP QSFP 0.5m -
X6558-R6 QSFP QSFP 2m -
X6559-R6 QSFP QSFP 5m -
X6590-R6 QSFP QSFP 10m SAS16
X6591-R6 QSFP QSFP 20m SAS16
X6594-R6 QSFP QSFP 1m SAS
X6595-R6 QSFP QSFP 3m SAS
X6543A-R6 QSFP miniSAS 2m -
X6544A-R6 QSFP miniSAS 5m -
QSFP
0.72 in.
(13.8 mm)
miniSAS
0.74 in.
(13.8 mm)
Optical Cables and Connectors
Part Number Begin End Length Notes
X6510A-R6 SC SC 5m OM2, 50u, 500MHz
X6511A-R6 SC SC 30m OM2, 50u, 500MHz
X6524-R6 2 x LC 2 x LC 2m OM2, 50u, 500MHz
X6553-R6 LC LC 2m OM3, 50u, 2000MHz
X6536-R6 LC LC 5m OM3, 50u, 2000MHz
X6554-R6 LC LC 15m OM3, 50u, 2000MHz
X6537-R6 LC LC 30m OM3, 50u, 2000MHz
X6523-R6 2 x LC 2 x SC 2m OM2, 50u, 500MHz
X6547-R6 LC SC 5m OM3, 50u, 2000MHz
X6546-R6 LC SC 30m OM3, 50u, 2000MHz
SC
0.91 in.
(23 mm)
LC
0.46 in.
(11.8 mm)
ST
ST
0.39 in.
(9.8 mm)
FC
0.39 in.
(9.9 mm)
MT-RJ
0.36 in.
(9.1 mm)
SFP/SFP+
0.53 in.
(13.7 mm)
HSSDC2
0.53 in.
(13.8 mm)
DB9
1.25 in.
(31.8 mm)
SFP/SFP+
Optical Module
0.53 in.
(13.7 mm)
0.53 in.
(13.7 mm)
DB9
SFP/SFP+
SFP/SFP+
Optical Module
MTP
0.49 in.
(12.5 mm)
0.53 in.
(13.7 mm)
SFP+
SFP+
0.72 in.
(13.8 mm)
QSFP
0.53 in.
(13.7 mm)
SFP+ RJ45
0.49 in.
(12.7 mm)
SFP+
Optical Module
0.53 in.
(13.7 mm)
0.53 in.
(13.7 mm)
Fabric-Attached Storage & V-Series
Card Type Part Number / Description Media
Optical Module FRU
(Mfr Part Number) Min Data ONTAP®6280 6240 6210 3270 3240 3210 2240
FIBRE CHANNEL
PCIe X1128A-R6
FCP TARGET 2-Port 4Gb Op - LC Fixed Optics
Non-removable 7.3, 8.0, 8.1 662
PCIe X1130A-R6
FCP TARGET 4-Port 4Gb Op - LC Fixed Optics
Non-removable 7.3, 8.0, 8.1 6 6 4 6 6 2
PCIe X1131A-R6
FCP TARGET 2-Port 8Gb Op - LC SFP module pre-installed (FTLF8528P2BCV-QL)
No optical FRU available 7.3, 8.0, 8.1 12 12 4 6 6 2
PCIe X1132A-R6
TARGET/DISK/TAPE 4-Port 8Gb Op - LC SFP module pre-installed (FTLF8528P3BCV-QL)
No optical FRU available 8.1.1 1211214662
PCIe X2053A-R6
TAPE 2-Port 4Gb Op - LC Fixed Optics
Non-removable 7.3, 8.0, 8.1 8 8 4 6 6 2
PCIe X2054A-R6
DISK/TAPE 4-Port 4Gb Op - LC Fixed Optics
Non-removable 7.3, 8.0 12 12 4 6 6 2
PCIe X2055A-R6
DISK 2-Port 4Gb Op - LC Fixed Optics
Non-removable 7.3, 8.0, 8.1 12 12 4 6 6 2
PCIe X2056-R6
TARGET/DISK/TAPE 4-Port 8Gb Op - LC X6588-R6
(AFBR-57D7APZ or FTLF8528P2BNV) 8.0.1, 8.1 3 3 1
Mezzanine X1150A-R6
TARGET/DISK/TAPE 2-Port 8Gb Op - LC X6588-R6
(AFBR-57D7APZ or FTLF8528P2BNV) 8.1 1
EHTERNET
PCIe X1038A-R6
NIC 2-Port GbE Op - LC Fixed Optics
Non-removable 7.3, 8.0, 8.1 1213 1213 4662
PCIe X1048A-R6
NIC 4-Port GbE Op - LC Fixed Optics
Non-removable 8.1.1 813 813 4662
PCIe X1049B-R6
NIC 4-Port GbE Cu - RJ45 -7.3.5, 8.0.2, 8.1 813 813 4 6 6 2
PCIe X1107A-R6
NIC 2-Port 10GbE Op - LC X6563-R6
(PLRXPL-SC-S43-42B or FTLX8571D3BCL) 7.3.2, 8.0, 8.1 6 6 2
PCIe X1117A-R6
NIC 2-Port 10GbE Op - LC X6569-R6
(FTLX8571D3BCV-IT) 8.0.1, 8.1 813 813 4614 614 214
PCIe X1139A-R6
Unifi ed Target 2-Port 10Gb Op - LC SFP module pre-installed
(PLRXPL-VC-S43-21-N) No optical FRU available 7.3.2, 8.0.1, 8.1 1013 1013 4 6 6 2
PCIe X1140A-R6
Unifi ed Target 2-Port 10Gb Cu - SFP+ Approved Twinax Cables 7.3.2, 8.0.1, 8.1 1013 1013 4 6 6 2
Mezzanine X1160A-R6
NIC 2-Port 10GbE Cu - SFP+ X6589-R6
(AFBR-703SDZ-NA2 or FTLX8571D3BCL-(NQ) 8.1 1
SCSI / SAS
PCIe X2028A-R6
TAPE 2-Port SCSI-LVD/SE
Cu - 68p
VHDCI -7.3, 8.0, 8.1 8 8 4 6 6 2
PCIe X2065A-R6
SAS, 4-Port, 6Gb Cu - QSFP -7.3.2, 8.0, 8.1 6 6 4 6 6 2
PCIe X2067-R6
SAS, 4-Port, 6Gb Cu - QSFP -8.0.1, 8.1 3 3 1
HA
PCIe X1927A-R6
MetroCluster FC-VI 2-Port 8Gb Op - LC SFP module pre-installed
(FTLF8528P2BCV-QL) No optical FRU available 8.0.1, 8.1 1 1 1 1 1 1
PCIe X3149-R6
NVRAM8 4GB Cu-QSFP X1956-R6 (optional) 8.0.1, 8.1 1 1 1
OTHER
PCIe X1142A-R6
SnapMirror® over FC 2-Port 8Gb Op - LC SFP module pre-installed
(FTLF8528P2BCV-QL) No optical FRU available 8.0.1, 8.1 4 4 3 1 1 1
PCIe X1970A-R5
Flash Cache - 256GB --7.3.5, 8.0.2, 8.1 2115
PCIe X1971A-R5
Flash Cache - 512GB --7.3.5, 8.0.2, 8.1 8 6 3 2 1
PCIe X1972A-R5
Flash Cache - 1TB --7.3.5, 8.0.2, 8.1 8 3 1 1
NEMA Plugs
IEC 60320 Plugs
C13
C14
IEC 60309 Plugs
32A
32A (red 5-pin)
L21-30P
L6-30P
L15-30P
60A (3-pin + PE)
System Cabinet Confi gurations
Confi guration PDUs
Per Cabinet PDU Part # Plug Type Service
Outlet
Cords
Per Side
Amps
Per Side
Outlets
Per Side Approx Power Thermal
NEMA
30A Single-Phase 4X8712C-R6 NEMA L6-30P
(input cord tethered to PDU) 30A 2 48 24
IEC 60320-C13 10 kW @ 208V 34075
NEMA
30A 3-Phase Delta 2X8719A-R6 NEMA L15-30P
(input cord tethered to PDU) 30A 1 41.5 24
IEC 60320-C13 8.6 kW @ 208V 29461
NEMA
30A 3-Phase Delta 2X8720A-R6 NEMA L21-30P
(input cord tethered to PDU) 30A 1 41.5 24
IEC 60320-C13 8.6 kW @ 208V 29461
IEC
32A Single-Phase 4X8713C-R6 IEC 60309-32A P+N+E
(input cord tethered to PDU) 32A 2 64 24
IEC 60320-C13 14.7 kW @ 230V 50239
IEC
32A 3-Phase Wye 2X8718A-R6 IEC 60309-32A 3P+N+E
(input cord tethered to PDU) 32A 1 96 24
IEC 60320-C13 22.1 kW @ 230V 75359
IEC
60A 3-Phase Delta 2X8721A-R6 IEC 60309-60A 3P+PE
(input cord tethered to PDU) 60A 1 83.1 24
IEC 60320-C13 17.2 kW@ 208V 58991
Dimensions Weight Clearance
Height 78.7 in. (200 cm) Empty Weight 307 lb. (138 kg) Front 30 in. (76.3 cm)
Depth 44.3 in. (112.5 cm) Loaded Weight 1807 lb. (820 kg) Rear 30 in. (76.3 cm)
Width 23.6 in. (60 cm) Top 12 in. (30 cm)
System Cabinet Part Numbers
Empty Cabinet
(No PDUs/Rails) X870D-R6
Rail Kit X877B-R6
Rail Kit X8783A-R6
Blank Panel
(3rd party pass through) X8784-R6
Bolt-Down Kit X878-R6
Interconnect Kit X879B-R6
Mounting Bracket Tie-Down
(6U Controllers only) X8773-R6
Mounting Bracket Tie Down
(2020 Controllers only) X8775-R6
Mounting Bracket Tie Down
(3200 Controllers only) X8778-R6
Mounting Bracket Tie Down
(DS4486 only) X8779-R6
Cable Mgmt. / Velcro Ring X893A-R6
1U Blank Panel X8776B-R6
2U Blank Panel X8778B-R6
Mounting kit for use with
Cisco Management switches
(pn/ X1965-R5)
X5528A-R6
Power Distribution
27 in. IEC60320 C13 TO C14 X800-42U-R6
48 in. IEC60320 C13 TO C14 X1558A-R6
3rd Party Cabinet Rail Kits
2 or 4-Post Rackmount Kit X5515A-R6
2 or 4-Post Rackmount Kit
(FAS2020 & FAS2040) X5518A-R6
4-Post Rackmount Kit
(Round Hole 4 Post Cabinet) X5525A-R6
4-Post Rackmount Kit X5526A-R6
2-Post Rackmount Kit
(DS2246) X5527A-R6
4-Post Rackmount Kit
(Square Hole 4 Post Cabinet) X5529A-R6
NetApp Disk Shelves
Model DS14mk4 FC DS14mk2 AT DS4243 DS4246 DS2246 DS4486 FibreBridge
6500N
Front View
Maximum Drive Quantity 14 14 24 24 24 48 -
Environmental Specifi caitons
Rack Height 3U 3U 4U 4U 2U 4U 1U
Weight
(Empty / Loaded)
77 lb. (35 kg)
50.06 lb. (23 kg)
77 lb. (35 kg)
50.06 lb. (23 kg)
110 lb. (49.9 kg)
53.7 lb. (24.4 kg)
110 lb. (49.9 kg)
53.7 lb. (24.4 kg)
56 lb. (25.4 kg)
34.6 lb. (15.7 kg)
150 lb. (68 kg)
82 lb. (33 kg) 8.75 lb. (3.97 kg)
AC Power5
300GB 15K FC 4.43A
450GB 15K FC 4.43A
600GB 15K FC 3.44A
750GB SATA 2.72A
1.0TB SATA 2.51A
2.0TB SATA 2.50A
100GB SSD 1.96A
450GB SAS 6.00A
600GB SAS 5.98A
1.0TB SATA 4.41A
2.0TB SATA 4.72A
3.0TB SATA 4.95A
900GB SAS 3.30A
1.0TB SATA 4.41A
2.0TB SATA 4.72A
3.0TB SATA 4.95A
(mixed SSD
+ SATA support)
450GB SAS 4.41A
600GB SAS 4.22A
900GB SAS 4.22A
3.0TB SATA 8.71A 1.0A @100V
0.5A @200V
BTU/hr6
300GB 15K FC 1,512
450GB 15K FC 1,512
600GB 15K FC 1,166
750GB SATA 924
1.0TB SATA 853
2.0TB SATA 849
100GB SSD 699
450GB SAS 2,047
600GB SAS 2,028
1.0TB SATA 1,499
2.0TB SATA 1,599
3.0TB SATA 1,690
900GB SAS 1,127
1.0TB SATA 1,499
2.0TB SATA 1,599
3.0TB SATA 1,690
(mixed SSD
+ SATA support)
450GB SAS 1,461
600GB SAS 1,441
900GB SAS 1,441
3.0TB SATA 2,970 342 @100V
342 @200V
Disk Shelf Part Numbers
Empty Shelf
(with AC PSU) X553A-R5 X561-R5 X556A-R6 (2x PSU)
X557A-R6 (4x PSU)
X556A-R6 (2x PSU)
X557A-R6 (4x PSU) X559A-R6 -
The FibreBridge 6500N
provides bridging
between FC and SAS
protocols for Stretch
and Fabric MetroCluster
confi gurations enabling
backend connectivity
to DS2246 and DS424x
disk shelves. 2 Fibre-
Bridges are required to
support a single shelf
stack (4 FibreBridges
minimum per MetroClu-
ster). Each FibreBridge
provides 2x 8Gb FC
ports and 1x 6Gb SAS
port (second SAS portis
unused).
Empty Shelf
(without PSU) X554A-R5 X562-R5 X558A-R6 X558A-R5 X567A-R6 X568A-R6
AC Power
Supply X511A-R5 X511A-R5 X518A-R6 X518A-R6 X519A-R6 X521A-R6
Quickship
Half Populated
DS4243-1504-12S-QS-R5 (300GB)
DS4243-1505-12S-QS-R5 (450GB)
DS4243-1507-12S-QS-R5 (600GB)
DS4243-0712-12A-QS-R5 (1.0TB)
DS4243-0724-12A-QS-R5 (2.0TB)
DS4243-0736-12A-QS-R5 (3.0TB)
DS4246-0712-12A-QS-R6 (1.0TB)
DS4246-0724-12A-QS-R6 (2.0TB)
DS4246-0736-12A-QS-R6 (3.0TB)
DS2246-1005-12S-QS-R5 (450GB)
DS2246-1007-12S-QS-R5 (600GB)
DS2246-1014-12S-QS-R5 (600GB)
DS2246-10.8TB-QS-R5 (900GB)
Quickship
Fully Populated
X54015A-ESH4-QS-R5 (450GB)
X64015A-ESH4-QS-R5 (600GB)
DSX-14.0TB-QS-R5 (1.0TB)
DSX-28.0TB-QS-R5 (2.0TB)
DS4243-SL02-24A-QS-R5 (100GB)
DS4243-1507-24S-QS-R5 (300GB)
DS4243-1511-24S-QS-R5 (450GB)
DS4243-1514-24S-QS-R5 (600GB)
DS4243-0724-24A-QS-R5 (1.0TB)
DS4243-0748-24A-QS-R5 (2.0TB)
DS4243-0772-24A-QS-R5 (3.0TB)
DS4246-0724-24A-QS-R6 (1.0TB)
DS4246-0748-24A-QS-R6 (2.0TB)
DS4246-0772-24A-QS-R6 (3.0TB)
DS4246-0772-24N-QS-R6 (3.0TB)
DS2246-1011-24S-QS-R5 (450GB)
DS2246-1014-24S-QS-R5 (600GB)
DS2246-1014-24N-QS-R5 (600GB) NSE
DS2246-21.6TB-QS-R5 (900GB)
DS4486-144TB-QS-R5
Disk Shelf Modules
ESH2
X5511A-R5 Supported ----- -
ESH4
X5512A-R5 Supported ----- -
AT-FCX
X5612A-R6 -Supported ---- -
IOM3
X5712A-R6 - - Supported - - - -
IOM6
X5713A-R6 ---Supported Supported Supported -
Minimum
Data ONTAP® Release 7.2.1, 7.3, 8.0, 8.1 7.0, 7.1, 7.2, 7.3, 8.0, 8.1 7.3.2, 8.0, 8.1 8.1.1 7.3.4, 8.0.1, 8.1.1 8.1.1 8.1
17
Get Involved With NetApp…
Join Tech OnTap
NetApp’s Tech OnTap program provides monthly IT insights plus
technical case studies, real-world best practices, behind the scenes
engineering interviews, exclusive invites to local user groups and
much, much more.
For more information, visit:
netapp.com/techontap/community
Feedback and questions can be sent to:
xdl-hardwareuniverse@netapp.com
TERMS AND ABBREVIATIONS
© 2012 NetApp, Inc. All rights reserved. Specifi cations are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
NA-035-1112
This document is subject to change without notice. Be sure to cross-reference the
online Hardware Universe web application at http://hwu.netapp.com for the most
current information. Hardware Universe is chartered under the NetApp Field Tech
Team and Pathway Enablement (FTTPE) organization.
The Hardware Universe Poster is printed on recycled paper. Please recycle after use.
Questions and feedback can be sent to xdl-hardwareuniverse@netapp.com.
Scan the QR Code to learn more about
the NetApp Hardware Universe site.
First, you need to have a smartphone or tablet equipped with a camera. It also has
to have a code-reading (QR) application.
To scan, simply open the app and hold your device’s camera up to the QR code.
Keep your hand steady and try to center the image of the QR code on your phone
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
data linked to the QR should automatically open up.
ACP – Alternate Control Path
BTU – British Thermal Unit
Cu – Copper Connector
EOA – End of Availability
EOS – End of Support
ESH – Electronically Switched Hub
FAS – Fabric-Attached Storage
FCP – Fibre Channel Protocol
FC – Ferrule Connector
FC – Fibre Channel
FRU – Field Replacement Unit
GbE – Gibabit Ethernet
HA – High Availability
HSSDC – High-Speed Serial
Data Connector
HT – Hyper-Threading
IB4X – Infi niBand 4X
IEC – International Electrotechnical
Commission
IOM3 – I/O Module 3Gbit per second
IOM6 – I/O Module 6Gbit per second
LC – Lucent Connector
LRC – Loop Resiliency Circuit
LUN – Logical Unit Number
MTP – Mechanical Transfer Pull-Off
NEMA – National Electrical Mfg.
Association
NIC – Network Interface Card
NVRAM – Nonvolatile RAM
Op – Optical Connector
PAM – Performance Acceleration Module
PSU – Power Supply Unit
QSFP – Quad Small Form-Factor Pluggable
RLM – Remote LAN Module
RPM – Revolutions Per Minute
SAS – Serial-Attached SCSI
SATA – Serial ATA
SC – Subscriber Connector
SFP – Small Form-Factor Pluggable
SSD – Solid State Drives
ST – Straight Tip Connector
TOE –TCP/IP Offl oad Engine
1 HA values shown refl ect a Controller+IOXM (CI) confi guration.
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000 bytes) and is derived based on the type,
size, and number of drives.
3 Max capacity shown can only be achieved using 3TB drives under
Data ONTAP 8.0.2 or greater.
4 Maximum aggregate size is calculated using base 2 arithmetic
(1TB = 240 bytes).
5 AC Power values shown are worst-case and refl ect system running on
one PSU, high fan speed, and power distributed over one power cord.
Please refer to the Site Requirements Guide on the NetApp Support site:
support.netapp.com for typical case values.
6 Thermal dissipation values shown are based on worst-case system
values. Please refer to the Site Requirements Guide on the NOW site
for more information.
7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on
the vertical FC boards, all are considered as on-board ports, can be
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
Operation at 1Gb speeds is not supported.
8 The number of onboard SAS ports differs based on the confi guration.
9 100 LUNs from one array using one array LUN group. Combined LUN
and NetApp disk can total 240 devices.
10 NVMEM on select FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
result in less memory for available to Data ONTAP.
11 Encrypted drive.
12 Double stack disk tray, 2 drives per tray.
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1, 20 in 8.0.2 and 8.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
14 Requires Data ONTAP 8.1 release or higher.
15 Flash Cache is not supported on the FAS3210 storage systems in
the Data ONTAP 8.1 release.
16 Minimum Data ONTAP Support - 7.3.5.1, 8.0.1P5, and 8.0.2 and later;
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS ports Storage Support - DS224x & DS424x.
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
17 The DS14mk2 AT disk shelf and disks will not be shipping in
Production starting 01/02/2013. The AT dongle that is not RoHS
2012 compliant (RoHS currently for Europe). Only spares of shelves
and spare hard drives FRUs can be shipped out in 2013.
NOTES
Interface (Gb/Sec) DS14 Model
Part No. Capacity RPM EOA/EOS
Minimum
Data ONTAP®1 2 4 mk2 mk4
FIBRE CHANNEL
X274B-R5 144GB 10K 05.2008
06.2013 6.4.5, 7.X, 8.0
X278A-R5 144GB 15K 11.2009
12.2014 6.4.5, 7.X, 8.0
X276A-R5 300GB 10K 03.2009
04.2014 7.2.1, 7.3, 8.0
X279A-R5 300GB 15K 01.2013 7.2.1, 7.3, 8.0, 8.1
X291A-R5 450GB 15K -7.2.5, 7.3, 8.0, 8.1
X292A-R5 600GB 15K -7.3.2, 8.0, 8.1
Storage Chassis
Part No. Capacity RPM EOA/EOS
Minimum
Data ONTAP®2220
2240
2U
2240
4U 4243 4246 2246
SAS
X309A-R6 3TB
encrypted 7K -8.1.1 11 11 11
X410A-R5 300GB 15K -7.3.2, 8.0, 8.1
X421A-R5 450GB 10K -7.3.4, 8.0.1, 8.1
X411A-R5 450GB 15K -7.3.2, 8.0, 8.1
X486A-R5 450GB 10K -8.1.1
X414A-R5 600GB
encrypted 15K -8.1 11
X416A-R5 600GB
encrypted 10K 8.1.1 11 11
X422A-R5 600GB 10K -7.3.4, 8.0.1, 8.1
X412A-R5 600GB 15K -7.3.2, 8.0, 8.1
X487A-R5 600GB 10K -8.1.1
X494A-R5 600GB
encrypted 10K -8.1.1 11
X423A-R5 900GB 10K -7.3.5, 8.0.2, 8.1
X488A-R5 900GB 10K -7.3.5, 8.0.2, 8.1
Interface (Gb/Sec) DS14 Model
Part No. Capacity RPM EOA/EOS
Minimum
Data ONTAP®1 2 4 mk2 mk4
FIBRE CHANNEL
X274B-R5 144GB 10K 05.2008
06.2013 6.4.5, 7.X, 8.0
X278A-R5 144GB 15K 11.2009
12.2014 6.4.5, 7.X, 8.0
X276A-R5 300GB 10K 03.2009
04.2014 7.2.1, 7.3, 8.0
X279A-R5 300GB 15K 01.2013 7.2.1, 7.3, 8.0, 8.1
X291A-R5 450GB 15K -7.2.5, 7.3, 8.0, 8.1
X292A-R5 600GB 15K -7.3.2, 8.0, 8.1
Storage Chassis
Part No. Capacity RPM EOA/EOS Minimum
Data ONTAP®2220
2240
2U
2240
4U 4243 4246 4486 mk2AT
SATA
X262B-R5 250GB 7.2K 05.2008
06.2013
7.1.1, 7.2, 7.3,
8.0 17
X267A-R5 500GB 7.2K 08.2010
09.2015
7.1, 7.2, 7.3, 8.0,
8.1 17
X310A-R5 500GB 7.2K 08.2010
09.2015 7.3.2, 8.0, 8.1
X268A-R5 750GB 7.2K 11.2009
12.2014
7.2.1, 7.3, 8.0,
8.1 17
X269A-R5 1TB 7.2K 05.2012
06.2017
7.2.3, 7.3, 8.0,
8.1 17
X302A-R5 1TB 7.2K - 7.3.2, 8.0, 8.1
X294A-R5 2TB 7.2K 05.2012
06.2017 7.3.2, 8.0, 8.1 17
X306A-R5 2TB 7.2K - 7.3.2, 8.0, 8.1
X308A-R5 3TB 7.2K - 8.0.2, 8.1
X478A-R5 3TB 7.2K - 8.1.1
X480A-R6 8TB
(2x4TB) 7.2K - 8.1.2 12
Storage Chassis
Part No. Capacity RPM EOA/EOS
Minimum
Data ONTAP®2220
2240
2U
2240
4U 4243 4246 2246
SAS
X309A-R6 3TB
encrypted 7K -8.1.1 11 11 11
X410A-R5 300GB 15K -7.3.2, 8.0, 8.1
X421A-R5 450GB 10K -7.3.4, 8.0.1, 8.1
X411A-R5 450GB 15K -7.3.2, 8.0, 8.1
X486A-R5 450GB 10K -8.1.1
X414A-R5 600GB
encrypted 15K -8.1 11
X416A-R5 600GB
encrypted 10K 8.1.1 11 11
X422A-R5 600GB 10K -7.3.4, 8.0.1, 8.1
X412A-R5 600GB 15K -7.3.2, 8.0, 8.1
X487A-R5 600GB 10K -8.1.1
X494A-R5 600GB
encrypted 10K -8.1.1 11
X423A-R5 900GB 10K -7.3.5, 8.0.2, 8.1
X488A-R5 900GB 10K -7.3.5, 8.0.2, 8.1
Storage Chassis
Part No. Capacity RPM EOA/EOS Minimum
Data ONTAP®2220
2240
2U
2240
4U 4243 4246 2246
SSD
X441A-R5 100GB N/A -8.1.1
X442A-R5 100GB N/A 08.2011 8.0.1
X446A-R6 200GB N/A -8.1.1
DS14mk2 AT 2TB SATA17
DS424x 600GB SAS
DS4486 6TB SATA (2 x 3TB)DS4486 8TB SATA (2 x 4TB)
DS14mk4 FC 600GB FC
DS424x 3TB SATA
DS2246
SAS
900GB
DS424x
200GB
SSD
2013
NETAPP
HARDWARE
UNIVERSE
DS4243/DS4246
7 in.
(17.8 cm)
17.7 in. (45 cm)
Depth: 24 in. (61 cm)
P
P
P
P
Depth DS14mk2 AT: 22 in. (55.2 cm) Depth DS14mk4 FC: 20 in. (50.8 cm)
5.25 in.
(13.3 cm)
17.6 in. (44.7 cm)
DS14mk4 FC
Depth: 9.9 in. (25.1 cm)
1.69 in.
(4.3 cm)
17.31 in. (43.97 cm)
+ +
6500N
FibreBridge
FAS/V6200
(Single controller show)
10.2 in.
(25.86 cm)
NVRAM8 adapter is placed in slot 2 in a FAS6200 series controller (as shown). FAS6210 model does not support IOXM.
Q
Q
Slot 3
Slot 6
Slot 5
Slot 4
Slot 13
Slot 16
Slot 14
Slot 15
Slot 7
Slot 10
Slot 9
Slot 8
Slot 1
Slot 11
Slot 12
+++++
P+++
Depth: 29 in. (73.66 cm)
17.53 in. (44.52 cm)
7 in.
(17.8 cm)
FAS2240-4
(HA confi guration show)
Depth: 24 in. (61 cm)
17.7 in. (44.9 cm)
P
P
M
M
5.12 in.
(13 cm)
FAS/V3200
(Single contoller shown)
P
Slot 1
Slot 2
Slot 5
Slot 3
Slot 6Slot 4
+
+
Depth: 24 in. (60.7 cm)
17.61 in. (44.7 cm)
3.4 in.
(8.6 cm)
P
Depth: 23.1 in. (58.7 cm)
FAS2240-2
(HA confi guration shown)
17.6 in. (44.7 cm)
M M P
3.4 in.
(8.6 cm)
P
FAS2220
(HA confi guration shown)
P
MM
Depth: 24.1 in. (61.2 cm)
17.6 in. (44.7 cm)
Depth: 20 in. (50.8 cm)
1.69 in.
(4.3 cm)
CN1601
17.5 in. (44.5 cm)
Depth: 20 in. (50.8 cm)
17.5 in. (44.5 cm)
1.69 in.
(4.3 cm)
CN1610
3.4 in.
(8.5 cm)
DS2246
Depth: 19.1 in. (48.4 cm)
17.6 in. (44.7 cm)
P PP P
6.87 in.
(17.4 cm)
17.6 in. (44.7 cm)
Depth: 27 in. (68.6 cm)
DS4486
P
P
P
P
Expansion Slot
PCIe
Gigabit Ethernet
RJ45
4Gb Fibre Channel
SFP
Serial-Attached SCSI
QSFP
Serial Console
RJ45
HA Interconnect
IB4X
Expansion Slot
PCI-X
10 Gigabit Ethernet
SFP+ +8Gb Fibre Channel
SFP+ +Alternate Control Path
RJ45 PRemote Management
RJ45
HA Interconnect
QSFP Q
Expansion Slot
Mezzanine MHA Interconnect
SFP+ +
Get Involved With NetApp…
Join Tech OnTap
NetApp’s Tech OnTap program provides monthly IT insights plus
technical case studies, real-world best practices, behind the scenes
engineering interviews, exclusive invites to local user groups and
much, much more.
For more information, visit:
netapp.com/techontap/community
Feedback and questions can be sent to:
xdl-hardwareuniverse@netapp.com
TERMS AND ABBREVIATIONS
© 2012 NetApp, Inc. All rights reserved. Specifi cations are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
NA-035-1112
This document is subject to change without notice. Be sure to cross-reference the
online Hardware Universe web application at http://hwu.netapp.com for the most
current information. Hardware Universe is chartered under the NetApp Field Tech
Team and Pathway Enablement (FTTPE) organization.
The Hardware Universe Poster is printed on recycled paper. Please recycle after use.
Questions and feedback can be sent to xdl-hardwareuniverse@netapp.com.
Scan the QR Code to learn more about
the NetApp Hardware Universe site.
First, you need to have a smartphone or tablet equipped with a camera. It also has
to have a code-reading (QR) application.
To scan, simply open the app and hold your device’s camera up to the QR code.
Keep your hand steady and try to center the image of the QR code on your phone
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
data linked to the QR should automatically open up.
ACP – Alternate Control Path
BTU – British Thermal Unit
Cu – Copper Connector
EOA – End of Availability
EOS – End of Support
ESH – Electronically Switched Hub
FAS – Fabric-Attached Storage
FCP – Fibre Channel Protocol
FC – Ferrule Connector
FC – Fibre Channel
FRU – Field Replacement Unit
GbE – Gibabit Ethernet
HA – High Availability
HSSDC – High-Speed Serial
Data Connector
HT – Hyper-Threading
IB4X – Infi niBand 4X
IEC – International Electrotechnical
Commission
IOM3 – I/O Module 3Gbit per second
IOM6 – I/O Module 6Gbit per second
LC – Lucent Connector
LRC – Loop Resiliency Circuit
LUN – Logical Unit Number
MTP – Mechanical Transfer Pull-Off
NEMA – National Electrical Mfg.
Association
NIC – Network Interface Card
NVRAM – Nonvolatile RAM
Op – Optical Connector
PAM – Performance Acceleration Module
PSU – Power Supply Unit
QSFP – Quad Small Form-Factor Pluggable
RLM – Remote LAN Module
RPM – Revolutions Per Minute
SAS – Serial-Attached SCSI
SATA – Serial ATA
SC – Subscriber Connector
SFP – Small Form-Factor Pluggable
SSD – Solid State Drives
ST – Straight Tip Connector
TOE –TCP/IP Offl oad Engine
1 HA values shown refl ect a Controller+IOXM (CI) confi guration.
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000 bytes) and is derived based on the type,
size, and number of drives.
3 Max capacity shown can only be achieved using 3TB drives under
Data ONTAP 8.0.2 or greater.
4 Maximum aggregate size is calculated using base 2 arithmetic
(1TB = 240 bytes).
5 AC Power values shown are worst-case and refl ect system running on
one PSU, high fan speed, and power distributed over one power cord.
Please refer to the Site Requirements Guide on the NetApp Support site:
support.netapp.com for typical case values.
6 Thermal dissipation values shown are based on worst-case system
values. Please refer to the Site Requirements Guide on the NOW site
for more information.
7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on
the vertical FC boards, all are considered as on-board ports, can be
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
Operation at 1Gb speeds is not supported.
8 The number of onboard SAS ports differs based on the confi guration.
9 100 LUNs from one array using one array LUN group. Combined LUN
and NetApp disk can total 240 devices.
10 NVMEM on select FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
result in less memory for available to Data ONTAP.
11 Encrypted drive.
12 Double stack disk tray, 2 drives per tray.
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1, 20 in 8.0.2 and 8.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
14 Requires Data ONTAP 8.1 release or higher.
15 Flash Cache is not supported on the FAS3210 storage systems in
the Data ONTAP 8.1 release.
16 Minimum Data ONTAP Support - 7.3.5.1, 8.0.1P5, and 8.0.2 and later;
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS ports Storage Support - DS224x & DS424x.
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
17 The DS14mk2 AT disk shelf and disks will not be shipping in
Production starting 01/02/2013. The AT dongle that is not RoHS
2012 compliant (RoHS currently for Europe). Only spares of shelves
and spare hard drives FRUs can be shipped out in 2013.
NOTES
Get Involved With NetApp…
Join Tech OnTap
NetApp’s Tech OnTap program provides monthly IT insights plus
technical case studies, real-world best practices, behind the scenes
engineering interviews, exclusive invites to local user groups and
much, much more.
For more information, visit:
netapp.com/techontap/community
Feedback and questions can be sent to:
xdl-hardwareuniverse@netapp.com
TERMS AND ABBREVIATIONS
© 2012 NetApp, Inc. All rights reserved. Specifi cations are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
NA-035-1112
This document is subject to change without notice. Be sure to cross-reference the
online Hardware Universe web application at http://hwu.netapp.com for the most
current information. Hardware Universe is chartered under the NetApp Field Tech
Team and Pathway Enablement (FTTPE) organization.
The Hardware Universe Poster is printed on recycled paper. Please recycle after use.
Questions and feedback can be sent to xdl-hardwareuniverse@netapp.com.
Scan the QR Code to learn more about
the NetApp Hardware Universe site.
First, you need to have a smartphone or tablet equipped with a camera. It also has
to have a code-reading (QR) application.
To scan, simply open the app and hold your device’s camera up to the QR code.
Keep your hand steady and try to center the image of the QR code on your phone
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
data linked to the QR should automatically open up.
ACP – Alternate Control Path
BTU – British Thermal Unit
Cu – Copper Connector
EOA – End of Availability
EOS – End of Support
ESH – Electronically Switched Hub
FAS – Fabric-Attached Storage
FCP – Fibre Channel Protocol
FC – Ferrule Connector
FC – Fibre Channel
FRU – Field Replacement Unit
GbE – Gibabit Ethernet
HA – High Availability
HSSDC – High-Speed Serial
Data Connector
HT – Hyper-Threading
IB4X – Infi niBand 4X
IEC – International Electrotechnical
Commission
IOM3 – I/O Module 3Gbit per second
IOM6 – I/O Module 6Gbit per second
LC – Lucent Connector
LRC – Loop Resiliency Circuit
LUN – Logical Unit Number
MTP – Mechanical Transfer Pull-Off
NEMA – National Electrical Mfg.
Association
NIC – Network Interface Card
NVRAM – Nonvolatile RAM
Op – Optical Connector
PAM – Performance Acceleration Module
PSU – Power Supply Unit
QSFP – Quad Small Form-Factor Pluggable
RLM – Remote LAN Module
RPM – Revolutions Per Minute
SAS – Serial-Attached SCSI
SATA – Serial ATA
SC – Subscriber Connector
SFP – Small Form-Factor Pluggable
SSD – Solid State Drives
ST – Straight Tip Connector
TOE –TCP/IP Offl oad Engine
1 HA values shown refl ect a Controller+IOXM (CI) confi guration.
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000 bytes) and is derived based on the type,
size, and number of drives.
3 Max capacity shown can only be achieved using 3TB drives under
Data ONTAP 8.0.2 or greater.
4 Maximum aggregate size is calculated using base 2 arithmetic
(1TB = 240 bytes).
5 AC Power values shown are worst-case and refl ect system running on
one PSU, high fan speed, and power distributed over one power cord.
Please refer to the Site Requirements Guide on the NetApp Support site:
support.netapp.com for typical case values.
6 Thermal dissipation values shown are based on worst-case system
values. Please refer to the Site Requirements Guide on the NOW site
for more information.
7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on
the vertical FC boards, all are considered as on-board ports, can be
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
Operation at 1Gb speeds is not supported.
8 The number of onboard SAS ports differs based on the confi guration.
9 100 LUNs from one array using one array LUN group. Combined LUN
and NetApp disk can total 240 devices.
10 NVMEM on select FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
result in less memory for available to Data ONTAP.
11 Encrypted drive.
12 Double stack disk tray, 2 drives per tray.
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1, 20 in 8.0.2 and 8.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
14 Requires Data ONTAP 8.1 release or higher.
15 Flash Cache is not supported on the FAS3210 storage systems in
the Data ONTAP 8.1 release.
16 Minimum Data ONTAP Support - 7.3.5.1, 8.0.1P5, and 8.0.2 and later;
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS ports Storage Support - DS224x & DS424x.
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
17 The DS14mk2 AT disk shelf and disks will not be shipping in
Production starting 01/02/2013. The AT dongle that is not RoHS
2012 compliant (RoHS currently for Europe). Only spares of shelves
and spare hard drives FRUs can be shipped out in 2013.
NOTES
Get Involved With NetApp…
Join Tech OnTap
NetApp’s Tech OnTap program provides monthly IT insights plus
technical case studies, real-world best practices, behind the scenes
engineering interviews, exclusive invites to local user groups and
much, much more.
For more information, visit:
netapp.com/techontap/community
Feedback and questions can be sent to:
xdl-hardwareuniverse@netapp.com
TERMS AND ABBREVIATIONS
© 2012 NetApp, Inc. All rights reserved. Specifi cations are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
NA-035-1112
This document is subject to change without notice. Be sure to cross-reference the
online Hardware Universe web application at http://hwu.netapp.com for the most
current information. Hardware Universe is chartered under the NetApp Field Tech
Team and Pathway Enablement (FTTPE) organization.
The Hardware Universe Poster is printed on recycled paper. Please recycle after use.
Questions and feedback can be sent to xdl-hardwareuniverse@netapp.com.
Scan the QR Code to learn more about
the NetApp Hardware Universe site.
First, you need to have a smartphone or tablet equipped with a camera. It also has
to have a code-reading (QR) application.
To scan, simply open the app and hold your device’s camera up to the QR code.
Keep your hand steady and try to center the image of the QR code on your phone
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
data linked to the QR should automatically open up.
ACP – Alternate Control Path
BTU – British Thermal Unit
Cu – Copper Connector
EOA – End of Availability
EOS – End of Support
ESH – Electronically Switched Hub
FAS – Fabric-Attached Storage
FCP – Fibre Channel Protocol
FC – Ferrule Connector
FC – Fibre Channel
FRU – Field Replacement Unit
GbE – Gibabit Ethernet
HA – High Availability
HSSDC – High-Speed Serial
Data Connector
HT – Hyper-Threading
IB4X – Infi niBand 4X
IEC – International Electrotechnical
Commission
IOM3 – I/O Module 3Gbit per second
IOM6 – I/O Module 6Gbit per second
LC – Lucent Connector
LRC – Loop Resiliency Circuit
LUN – Logical Unit Number
MTP – Mechanical Transfer Pull-Off
NEMA – National Electrical Mfg.
Association
NIC – Network Interface Card
NVRAM – Nonvolatile RAM
Op – Optical Connector
PAM – Performance Acceleration Module
PSU – Power Supply Unit
QSFP – Quad Small Form-Factor Pluggable
RLM – Remote LAN Module
RPM – Revolutions Per Minute
SAS – Serial-Attached SCSI
SATA – Serial ATA
SC – Subscriber Connector
SFP – Small Form-Factor Pluggable
SSD – Solid State Drives
ST – Straight Tip Connector
TOE –TCP/IP Offl oad Engine
1 HA values shown refl ect a Controller+IOXM (CI) confi guration.
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000 bytes) and is derived based on the type,
size, and number of drives.
3 Max capacity shown can only be achieved using 3TB drives under
Data ONTAP 8.0.2 or greater.
4 Maximum aggregate size is calculated using base 2 arithmetic
(1TB = 240 bytes).
5 AC Power values shown are worst-case and refl ect system running on
one PSU, high fan speed, and power distributed over one power cord.
Please refer to the Site Requirements Guide on the NetApp Support site:
support.netapp.com for typical case values.
6 Thermal dissipation values shown are based on worst-case system
values. Please refer to the Site Requirements Guide on the NOW site
for more information.
7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on
the vertical FC boards, all are considered as on-board ports, can be
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
Operation at 1Gb speeds is not supported.
8 The number of onboard SAS ports differs based on the confi guration.
9 100 LUNs from one array using one array LUN group. Combined LUN
and NetApp disk can total 240 devices.
10 NVMEM on select FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
result in less memory for available to Data ONTAP.
11 Encrypted drive.
12 Double stack disk tray, 2 drives per tray.
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1, 20 in 8.0.2 and 8.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
14 Requires Data ONTAP 8.1 release or higher.
15 Flash Cache is not supported on the FAS3210 storage systems in
the Data ONTAP 8.1 release.
16 Minimum Data ONTAP Support - 7.3.5.1, 8.0.1P5, and 8.0.2 and later;
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS ports Storage Support - DS224x & DS424x.
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
17 The DS14mk2 AT disk shelf and disks will not be shipping in
Production starting 01/02/2013. The AT dongle that is not RoHS
2012 compliant (RoHS currently for Europe). Only spares of shelves
and spare hard drives FRUs can be shipped out in 2013.
NOTES

Navigation menu