Product Information:

The SC-2062 is a board that can be used with various accessories and modules. It is recommended to refer to Chapter 8 of the SC-205X User Manual for information on the signals associated with each connector. The SC-2040 Series Boards should not be used with the SC-2056. Although you can use more than one SC-2042-RTD or SC-2043-SG with a single SC-2056, you can specify only one board when configuring your NI-DAQ driver software with WDAQCONF or the NI-DAQ Control Panel. Using both an SC-2042-RTD and an SC-2043-SG at the same time results in erroneous data from one of the boards. The AMUX-64T Board and BNC-2081/BNC-2082 Adapter Boards are not compatible with the SC-2056 and should not be used.

Product Usage Instructions:

When using the SC-2062 board, it is important to refer to Chapter 8 of the SC-205X User Manual for information on the signals associated with each connector. The SC-2040 Series Boards should not be used with the SC-2056. If you want to use multiple SC-2042-RTD or SC-2043-SG boards, you can only specify one board when configuring your NI-DAQ driver software with WDAQCONF or the NI-DAQ Control Panel. It is recommended not to use both an SC-2042-RTD and an SC-2043-SG at the same time as this will result in erroneous data from one of the boards.
The AMUX-64T Board and BNC-2081/BNC-2082 Adapter Boards are not compatible with the SC-2056 and should not be used. Ensure that you are using compatible accessories and modules with the SC-2062 board to avoid any issues.
This note contains information on the use of various accessories with the SC-2056 board. Refer to Chapter 8, SC-2056 Board, of the SC-205X User Manual, for information on the signals associated with each connector.

SC-204X Series Boards
  • SC-2040
    Using the SC-2040 with the SC-2056 is not recommended.
  • SC-2042 and SC-2043-SG
    You can connect up to four SC-2042-RTDs or four SC-2043-SG boards to connectors J4–J7 of the SC-2056. Connectors J4–J7 and J8 share digital signals so you must be careful not to double-drive these shared signals. Although you can use more than one SC-2042-RTD or SC-2043-SG with a single SC-2056, you can specify only one board when configuring your NI-DAQ driver software with WDAQCONF or the NI-DAQ Control Panel.
    When you are using more than one SC-2043-SG with the SC-2056, the board connected to J4 (analog channels 0–15 of the AT-MIO-64E-3) scales data correctly using NI-DAQ but your application program must scale the data in the remaining SC-2043-SG boards.
    Note:
    Do not connect both an SC-2042-RTD and an SC-2043-SG to the SC-2056. Using the SC-2042-RTD requires that you put your DAQ board in differential (DIFF) mode while your SC-2043-SG requires that you put your DAQ board in nonreferenced single-ended (NRSE) mode. Your DAQ board can only operate in one mode at a time so using the SC-2042-RTD and the SC-2043-SG boards simultaneously results in erroneous data from one of the boards.
SC-206X Series Boards

You can connect the SC-2060, SC-2061, or SC-2062 to connector J8 of the SC-2056. Connectors J4–J7 and J8 share digital signals so you must be careful not to double-drive these shared signals.
SC-207X Series Breadboards
You can connect the SC-2070 or SC-2072 to connectors J4–J7 of the SC-2056. Connectors J9–J13 and J4–J7 share analog signals so you must be careful not to double-drive these shared signals.
NI-DAQ® is a trademark of National Instruments Corporation. Product and company names are trademarks or trade names of their respective companies.
371204A-01 © Copyright 1995 National Instruments Corporation. All rights reserved. December 1995

SSR Series Modules

You can connect the SSR Series modules and the eight-channel SSR backplane to connector J8 of the SC-2056. Connectors J4–J7 and J8 share digital signals so you must be careful not to double-drive these shared signals.
5B Series Modules
You can connect the 5B Series modules and backplane to connectors J9–J13 of the SC-2056.
Connectors J9–J13 and J4–J7 share analog signals so you must be careful not to double-drive these shared signals
AMUX-64T Board
Using the AMUX-64T with the SC-2056 is not recommended.
BNC-208X Series Adapter Boards

  • BNC-2080
    You can connect the BNC-2080 to connectors J4–J7 of the SC-2056. Connectors J4–J7 and J9–J13 share analog signals so you must be careful not to double-drive these shared signals.
  • BNC-2081 and BNC-2082
    The BNC-2081 and BNC-2082 are not compatible with the SC-2056 and should not be used.

CB-50 Connector Block
You can connect the CB-50 to connectors J4–J7 of the SC-2056. Connectors J4–J7 and J8 share digital signals so you must be careful not to double-drive these shared signals.
SCB Connector Blocks

  • SCB-68
    You can connect the SCB-68 to connectors J4–J7 of the SC-2056 with the appropriate cable and adapter. Connectors J4–J7 and J8 share digital signals so you must be careful not to double-drive these shared signals.
  • SCB-100
    You can connect the SCB-100 to connectors J4–J7 of the SC-2056 with the appropriate cable and adapter. Connectors J4–J7 and J8 share digital signals so you must be careful not to double-drive these shared signals.

COMPREHENSIVE SERVICES

We offer competitive repair and calibration services, as well as easily accessible documentation and free downloadable resources.
SELL YOUR SURPLUS
We buy new, used, decommissioned, and surplus parts from every NI series.
We work out the best solution to suit your individual needs.
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
1-800-915-6216
www.apexwaves.com
sales@apexwaves.com

Documents / Resources

NATIONAL INSTRUMENTS SC-2056 Relay [pdf] Owner's Manual
SC-2062, SC-2056, SC-2040, SC-2042-RTD, SC-2043-SG, SC-207X, SSR Series Modules, 5B Series Modules, AMUX-64T Board, BNC-2081, BNC-2082, CB-50 Connector Block, SCB Connector Blocks, SC-2056 Relay, Relay

References

Leave a comment

Your email address will not be published. Required fields are marked *