General Calogue 2013

Page 1

> 2013-2014

Product photos are purely indicative. Due to technical improvements and/or changes in regulatory standards, product specifications are subject to change without notice.

Follow us on Social Networks

CATGENX0Y13CREN

GENERAL CATALOGUE

RPS S.p.A. - Member of the Riello Elettronica Group Viale Europa, 7 - 37045 LEGNAGO (Verona) - Italy T +39 0442 635811 - F +39 0442 629098 www.riello-ups.com - riello@riello-ups.com

GENERAL CATALOGUE > 2013-2014



Reliable power for a sustainable world


Contents Key

4

Company

Uninterruptible power supplies (UPS) iPlug

26

iDialog

30

Riello Elettronica and Riello UPS

6

Net Power

32

Our roots and our history

8

Vision

34

Riello and Ducati

9

Dialog Vision

38

Vision Dual

42

Sentinel Pro

46

Sentinel Dual Low Power

50

Sentinel Dual High Power

54

Sentinel Power Green

60

Sentinel Power

64

Multi Sentry

68

Multi Guard

74

Multi Guard Industrial

78

Master MPS

82

Master HP

90

Master HP UL

94

Master Industrial

98

Riello UPS. Brand values

10

Quick references Guide to choosing a UPS

14

Options and accessories compatibility table

16

Areas / Scope SoHo Area

18

Data Centre Area

19

E-Medical Area

20

Industry Area

21

Transport Area

22

Emergency Area

23

Master FC400

100

Master Static Bypass

102

Multi Switch

106

Multi Switch ATS

108

Master Switch STS Single-phase

110

Master Switch STS Three-phase

112


Power solutions

Connectivity

SuperCaps UPS

116

Point to point

136

Master VDC

118

Multipoint

137

Power Box

122

UPS in parallel

137

Central Supply Systems CSS

124

Several systems in parallel and STS

138

Field bus over Ethernet

138

Modbus serial field bus

139

Profibus DP serial field bus

139

Software and accessories PowerShield3

128

PowerNetGuard

129

NetMan 101/102 Plus

130

Services and contacts

NetMan 202 Plus

130

Services and Consultancy

140

MultiCOM 301/302

131

Operating Offices

142

MultiCOM 351/352

131

MultiCOM 372

131

MultiCOM 382

132

MultiCOM 401

132

Multi I/O

132

I/O

133

Kit for AS400 and i-Series

133

GSM Modem

133

RTG 100

134

Multi Panel

134

Multi Pass 10, 16 & 16-R

135

MBB32A

135

MBB100A

135


Key 1:1

Single-phase input and output

UPS suitable for home - small office applications

1:3

Single-phase input, three-phase output

UPS suitable for data centre applications

3:1

Three-phase input, single-phase output

UPS suitable for electro-medical applications

3:3

Three-phase input and output

UPS suitable for industrial applications

1-3:1

Single-phase or three-phase input, single-phase output

UPS suitable for transport applications (railways, airports, naval)

1-3:3

Single-phase or three-phase input, three-phase output

UPS suitable for emergency applications

VI

TYPE

VFD TYPE

VFI TYPE

4

UPS Line Interactive (Voltage Independent)

UPS VFD (Voltage Frequency Dependent)

UPS Online (Voltage Frequency Independent)


1

UPS with UL certificate

UPS classification Eco Level = 1

UPS with GS Nemko certificate

2

UPS classification Eco Level = 2

UPS ready for use in smart grids UPS classification Eco Level = 3 3

Battery Swap. The batteries can be replaced during operation UPS classification Eco Level = 4 4

UPS that can be combined with a flywheel 5

UPS classification Eco Level = 5

UPS also available with supercaps instead of batteries 6

Energy share. The load supplied from these sockets is not battery supported.

UPS classification Eco Level = 6

Plug and play. The UPS can be installed without the need for qualified personnel Installation and initial start up should be carried out by qualified personnel

The device has a USB port

www.riello-ups.com

5


Riello Elettronica and Riello UPS A global force

Riello Elettronica, part of the Riello Industries group, represents an Italian model for a global company. The Riello UPS brand is now a world leader in the uninterruptible power supplies market.

Riello Elettronica Riello Elettronica is the parent company of a group of industrial companies. Founded in 1986, Riello Elettronica initially manufactured switching power supplies for information technology applications, before moving into the manufacture of uninterruptible power supplies (UPS). In 1995 Riello Elettronica took on its present structure, organised as a holding company for the shares of the Group's businesses. In the meantime, the core business was extended to include energy, automation and safety.

Energy: produce it, distribute it, store it Thanks to Riello UPS, Riello Elettronica is today one of the four largest manufacturers of uninterruptible power supplies in the 6

world, with a complete range of UPS able to satisfy any energy requirement, from individual personal computers to the large systems used in banks, hospitals and airports, where operational continuity is crucial. Of equal importance is Aros Solar Technology's contribution to the Group. This company designs, manufactures and sells solar inverters and solutions for photovoltaic energy. Most of the manufacturing takes place in the plants in Legnago (Verona) and Cormano (Milano). The direct monitoring of international markets allows the Group to operate a single global strategy, expressed locally in the form of coherent sales policies that are easily adaptable to the realities of individual markets. In addition, Riello Elettronica's strong grounding in European

and Asian marketplaces is fundamentally important to procurement, ensuring rapid, efficient and above all monitored selection and purchasing processes, especially with regards to the high quality electronic components used in the manufacturing process.

Not just energy The Riello Elettronica group is also very active in the civil and industrial safety sectors, from domotics to oil hydraulic applications, through other industrial companies such as AVS Electronics, Cardin, Innovatech, Gamma System, Ceimu and Telcoma, which often collaborate together on large projects. AVS Electronics, for example, is the national leader in the manufacture of alarm and anti-intrusion systems and it combines its


products with home automation systems made by Innovatech, offering a range of solutions able to communicate over a wireless network and interconnect the different domestic functions using intelligent terminals. Domotics and photovoltaic technology in particular are driving the Riello Elettronica group into the future, creating new solutions for environmental wellbeing and everyday comfort supplied by energy from sustainable sources. The Group's companies are making the home intelligent; turning it into a place that can also be remotely controlled via Internet. Using a tablet, a notebook or a smart phone, the solutions offered by the Riello Elettronica Group allow you to monitor energy consumption, prevent black outs, keep out intruders, adjust the ambient temperature, switch on lights, open doors and gates, locate and stop water and gas leaks, etc. Industrial safety and oil hydraulics are covered by Gamma System and Ceimu respectively. Gamma System manufactures electronic presence sensors and photoelectric barriers for monitoring access and for the safety of manufacturing machinery and systems in general. Ceimu manufactures servo controls, cylinders and oil hydraulic systems for general mechanical applications.

Riello Industries The Riello Industries group is the operating structure of the Riello family of companies.

Active since 1922, it includes the holding company Riello Elettronica and various other businesses in the Riello galaxy. The Riello family of companies distinguishes itself in Italy for its innovative entrepreneurial structure. Despite being structured according to Anglo-Saxon governance models, which allow for the effective and rapid coordination of a large number of companies operating in bordering technological and commercial areas, it also manages to exceed the boundaries of a classic holding company by remaining closely connected to the territory and to the individual companies. The Family Company Agreement is an

RIELLO ENERDATA

ENERGY Area

RIELLO TDL

important part of this; a single central force that defines and structures decisions related to both stock options and operational management. Riello Industries is governed by Pilade Riello. His sons Pierantonio, Andrea, Giuseppe and Nicola, each control their own core businesses and the remaining shares are divided equally between the other brothers. Each following their own independent orbit, the companies belonging to the group rotate around this centre. They are held together by the Family Company Agreement, but they still retain their own autonomy and specific sector.

RIELLO UPS

AROS

CPS MARM-UPS

Riello UPS

Riello PCI INDIA

Riello onduleurs

Riello UPS ASIA

RIELLO ELETTRONICA s.p.a.

RPS

ALARM INTERNATIONAL SYSTEM

GAMMA SYSTEM

SAFETY AND AUTOMATION Area

Ceimu Avs eLECTRONICS

Cardin ELETTRONICA

AUTOMATIC INTERNATIONAL Security

TELCOMA AUTOMATIONS Cardin ELETTRONICA France

www.riello-ups.com

7


Our roots and our history Riello Elettronica has been a solid point of reference on the industrial world stage for 25 years, gaining credibility as well as differentiating its presence in DIVERSIFIED markets.

Guided successfully by Pierantonio Riello since the company was first set up, Riello Elettronica is about to celebrate its 25th anniversary as the market leader in Italy and one of the top players internationally in the energy conversion sector and in the manufacture of uninterruptible power supplies (UPS), intelligent electronic devices that operate as electrical power reserves in the event of mains power black outs. Energy conversion is the group's core business area, this also includes new technologies for harvesting clean and renewable energy sources via the manufacture of solar

8

inverters, a sector in which Riello Elettronica has become a national player. Energy, but not only: the group has also been successfully investing in automation and civil and industrial safety for several years. The group owns five manufacturing sites in Italy, twenty subsidiaries in Europe, China, India and Australia, and is present in over 80 countries worldwide. This is the Riello Elettronica Group today, the expression of an entrepreneurial tradition focused on innovation, global challenges and the development of ‘made in Italy’ technologies in the international marketplace.


Riello UPS: Ducati sponsor since 2007

Perfect synergy

High performance Unlimited energy Italian technology

Riello UPS is the official sponsor of the Ducati Corse MotoGP Team. Our partnership with Ducati provides Riello UPS with high levels of visibility and worldwide prestige. The two companies share values and principles that unite them in perfect synergy.

This is what we have in common with Ducati

www.riello-ups.com

9


Riello UPS Brand values

“Reliable power for a sustainable world� - the Riello UPS philosophy condensed into a few simple words - a global brand constantly searching for the most innovative solutions

Innovation - the secret of an all-Italian success story Riello UPS offers a vast range of products, organised into 20 ranges of uninterruptible power supplies (UPS)based on several different state-ofthe-art technological architectures. Thanks to its two research centres in Legnago (Verona) and Cormano (Milan), world class centres of excellence for the design, development and testing of uninterruptible power supplies, Riello UPS can constantly innovate is product portfolio, keeping it at the top in terms of performance, reliability and competitivity. In addition, in the event of large tenders or commissions 10

Riello UPS often also provides bespoke solutions based on the specifications provided, demonstrating its attention to the customer's individual . Riello UPS designs and manufactures its UPS in Italy in order to maintain direct control over quality and reliability standards by closely following the entire manufacturing process, sales and aftersales service. This strategy allows for a process of continuous improvement, monitoring customers' opinions and using them to make rapid adjustments to optimise features as required by the market. This process of continuous improvement, as well as having a direct effect and benefit on sales and after-sales service,

helps to further consolidate Riello UPS's image as a reliable, dynamic and quality-oriented company. It doesn't stop here however: the solid results achieved by Riello UPS in the development of UPS solutions equipped with completely innovative and avant-guarde technologies such as the PowerBox, SuperCaps UPS, and Smart Grid Ready UPS, i.e. ready for intelligent power distribution grids which represent the future of energy supply, are the best demonstration that innovation and quality really are the secrets of Riello UPS's success.


Reliable power for a sustainable world Riello UPS manufactures effective and efficient solutions that ensure power quality and business continuity, guaranteeing power supply and the correct operation of systems even in the event of critical situations. Riello UPS is constantly implementing new solutions into its products that are aimed at reducing power consumption by increasing efficiency and actively participating in the promotion of sustainable development. To this end the company also sets up ecological projects and makes large investments in the development of new

technologies for harvesting clean and renewable energy sources. Riello UPS's social commitment aims to help the present as well as positively affecting the future, combining the inevitable need for energy with environmental protection. The environmental management system employed by Riello UPS is ISO14001 certified. Riello UPS has always been a strong supporter of the Code of Conduct on Energy Efficiency and Quality of AC Uninterruptible Power Systems, a document signed by the major European manufacturers of UPS addressed to the European Commission. It sets out the energy efficiency targets for power

ranges from 300 VA to >200 kVA, from 25% to 100% loads. Riello UPS is also the first European manufacturer to identify its products in terms of energy efficiency.

www.riello-ups.com

11


Eco Energy Levels

availability of the services provided. Equipment must operate at the highest possible levels of efficiency to reduce the strain on critical power supplies and minimise the effect on the installation area. Riello UPS models have always been compliant with the highest levels of efficiency in terms of energy protection and are classified according to a scale with 6 levels, corresponding with the efficiency value of the UPS with respect to the European Code of Conduct; this is known as the Eco Energy Level.

Riello UPS uninterruptible power supplies power some of the most critical data centres and servers in use today. Within these environments, energy management is critical. Running costs must be minimised without compromising resilience, i.e. the ability to adapt to adverse external conditions whilst ensuring complete

ECO Mode

ECo Mode

> standard CoC

ECo Mode

CoC level

= standard CoC

ECo Mode

< standard CoC 1

6 5

2 3

The human factor, added value The concepts of product quality and excellence are central to Riello UPS's corporate philosophy, but this is combined with a further concept: the value of people, whether they are customers, users or colleagues. At every staff level in Riello UPS, the sense of belonging to the company and respect for others has created an excellent working environment, which has been instrumental in achieving the great results enjoyed by Riello UPS. The team work that leads everyone to give their best every day, coordinating with colleagues to achieve the set results 12

4

is the result of the careful selection, management and training of staff, but also and above all thanks to a healthy attitude of sharing targets at all levels and an ethical belief in added value. One of the secrets of Riello UPS's success as a company is the reciprocal respect for each person's contributions and the shared effort to ensure the best levels of service and highest levels of customer satisfaction. Proof of this are the awards that Riello UPS has received and continues to receive, the latest from Frost & Sullivan, who nominated Riello UPS “Company of the Year 2012�.

The ECO Energy Level is a tool implemented by Riello UPS to help customers to identify the products with the highest levels of efficiency in terms of energy protection; the 6 levels have recently been updated to comply with the stringent new efficiency levels that the CoC requires for 2013-2014. In addition to this, the availability of the Smart Mode provides a further method for improving efficiency, improving the Eco Energy Levels assessment. Riello UPS ‘s Eco Energy Level is more than just a concept; it is a system that demonstrates how the UPS that get the highest marks (levels 4, 5 and 6) are more efficient, and therefore more beneficial economically and environmentally. The Eco Energy Level system demonstrates both how the most efficient UPS provide energy savings that allow the cost of their purchase to be recovered quickly with respect to standard efficiency UPS, as well as how their use leads to significant reductions in carbon emissions into the atmosphere. An Energy Saving Calculator is available at www.riello-ups.com to help calculate the energy and cost savings as well as the reduction in CO2 emissions that can be achieved by using Riello UPS Eco Energy Level products.


UPS Smart Grid Ready

ďżź The evolution of electrical power grids is a key element for achieving greater sustainability; particularly fundamental are the power management systems for balancing supply and demand, for using energy in the most sustainable and efficient way: smart grids. Smart grids are nothing more than power grids that efficiently integrate and manage the behaviour and actions of all the connected consumers (generators, output points, etc.), with the aim of ensuring the economically efficient operation of the electrical system, with

a high level of safety, continuity and quality of supply. Smart grids not only introduce new concepts to power grids but also new business opportunities with regards to installations with UPS: batteries of uninterruptible power supplies represent significant investments, but they are only partially used. Using these distributed power accumulators and generating business in power accumulation scenarios will become fundamentally important. Smart grids also mean the integration of different energy sources, two-way flow, information exchange grids and centralised management. In this new scenario installations with UPS can take on new roles, becoming virtual power plants, decentralised power accumulation

systems, variable power generators and above all they can be combined with renewable energy sources. In order to be “smart grid ready�, UPS must allow for the implementation of power accumulation solutions, and at the same time ensure extremely high levels of efficiency. They must also be able to independently select the most efficient operating method based on the status of the grid. They must be able to electronically interface with the energy manager using the smart grid communication network. Always open to technological innovation, Riello UPS has invested in research and technology to develop smart grid ready products, creating the Master HP, Master MPS and Multi Sentry ranges, the first smart grid ready UPS on the market.

SMART Meter

ENERGY MANAGER System

Photovoltaic Central

Battery set SMART Meter SMART Meter

UPS Riello

Server room SMART Meter

Power distribution grid

www.riello-ups.com

13


Guide to choosing a UPS Choose the main parameters required for your installation and discover which UPS in the Riello range can meet your needs. Further details are provided in the dedicated pages for each product.

T

-

iDIALOG

T

-

NET POWER

T

-

VISION

T T

opt 1 opt 1

R

DIALOG VISION

R

opt 1

SENTINEL PRO

T

opt 1

SENTINEL DUAL low power

T

SENTINEL DUAL high power

T

opt 1

R R

A

B

opt 1

SENTINEL POWER GREEN

T

C

D

opt 1

SENTINEL POWER

T

E

F

opt 1

MULTI SENTRY

T

opt 2

MULTI GUARD

M

opt 1

MULTI GUARD INDUSTRIAL

M

opt 2

MASTER MPS

T

MASTER HP

std

2

T

std

2

MASTER HP UL

T

std

2

MASTER INDUSTRIAL

T

std

2

EMERGENCY solution CSS 1 h

T

EMERGENCY solution CSS 3 h

T

MASTER FC400

T

G

G

opt 2 G H

std

2

std

2 2

MASTER STATIC Bypass

-

-

-

T

-

-

-

-

-

std

MULTI SWITCH

-

-

-

R

-

-

-

-

-

-

MULTI SWITCH ATS

-

-

-

R

-

-

-

-

-

std

1

MASTER SWITCH STS 1ph

-

-

-

R

-

-

-

-

-

std

1

MASTER SWITCH STS 3ph

-

-

-

T

-

-

-

-

-

std

Emergency

Transport

Industry

e-Medical

DataCentre

Soho

Areas

EPO

# Slot

Dry contact

RS232

USB

Transforbased

Transformerless

Parallelable

Internal batteries

Manual bypass

3-3

1/3 - 3

1/3 - 1

Connect

iPLUG

VISION DUAL

14

Specifications

1-1

Instal

UPS Online

UPS Line interactive

UPS VFD

Type

Tower / Rack / Modular

Parameters


A

3.3 - 4 - 5 - 6 - 8 - 10 kVA

E

5 - 6 kVA

J

1รท8 x 15 kVA

B

6.5 - 8 - 10 kVA

F

6.5 - 8 - 10 kVA

K

1รท8 x 20 kVA

C

6 kVA

G

3ph input only

D

8 - 10 - 15 - 20 kVA

H

Except 30 kVA

opt std

optional standard

info

400 VA 500 VA 600 VA 700 VA 800 VA 1000 VA 1100 VA 1200 VA 1500 VA 1600 VA 2000 VA 2200 VA 3000 VA 3300 VA 4000 VA 5000 VA 6000 VA 6500 VA 8000 VA 10 kVA 12 kVA 15 kVA 20 kVA 30 kVA 40 kVA 60 kVA 65 kVA 80 kVA 100 kVA 120 kVA 125 kVA 160 kVA 200 kVA 250 kVA 300 kVA 400 kVA 500 kVA 600 kVA 800 kVA

Power

UPS page

Key

26 30 32 34 38 42 46 50 54 60 64 68 74

J

78

K

82 90 94 98 124 124 100 102 106 108 110 112

www.riello-ups.com

15


Options and accessories compatibility table Identify the UPS that supports the software and accessories your installation requires.

iPLUG iDIALOG NET POWER VISION VISION DUAL DIALOG VISION SENTINEL PRO SENTINEL DUAL low power SENTINEL DUAL high power SENTINEL POWER GREEN SENTINEL POWER MULTI SENTRY MULTI GUARD MULTI GUARD INDUSTRIAL MASTER MPS MASTER HP MASTER HP UL MASTER INDUSTRIAL EMERGENCY solution CSS 1 h EMERGENCY solution CSS 3 h MASTER FC400 MASTER STATIC Bypass MULTI SWITCH MULTI SWITCH ATS MASTER SWITCH STS 1ph MASTER SWITCH STS 3ph 16

N

Box - Relay I/O Card & Modbus/Jbus interface

MULTI I/O

Box - Profibus DP interface

MULTICOM 401

Card - Relay I/O interface

MULTICOM 382

Card - RS232 interface

MULTICOM 372

Card - Interface duplexer

MULTICOM 352

Box - Interface duplexer

MULTICOM 351

Card - Modbus/Jbus interface

MULTICOM 302

Box - Modbus/Jbus interface

MULTICOM 301

Card - Ethernet - SNMP v3

NETMAN 202 PLUS

Card - Ethernet -SNMP

Box - Ethernet -SNMP

NETMAN 102 PLUS

Accessories

NETMAN 101 PLUS

POWERNETGUARD

POWERSHIELD3

Inventory manager software

Software

Shutdown software

Parameters


Key

L

3300 - 4000 VA

M

20 kVA 1:1, 40 kVA 3:3

N

Included only in version N

MANUAL Bypass 100 A MBB 100A

AUTOMATIC Bypass 16A RACK MBBR 16A

AUTOMATIC Bypass 16A MBB 16A L

L

M

M

UPS page

L

Other specific options can be found on the dedicated product pages

ACRONYMS

L

info

MANUAL Bypass 16A RACK MBBR 16A

MANUAL Bypass 16A MBB 16A

MODEM GSM

MODEM 56k

Modem GPRS

RTG 100

Remote Display interface

MULTIPANEL

INTERFACE KIT AS400

Accessories

iPLUG

IPG

26

iDIALOG

IDG

30

NET POWER

NPW

32

VISION

VST

34

VISION DUAL

VSD

38

DIALOG VISION

DVR

42

SENTINEL PRO

SEP

46

SENTINEL DUAL low power

SDH

50

SENTINEL DUAL high power

SDL

54

SENTINEL POWER GREEN

SPM / SPH

60

SENTINEL POWER

SPW / SPT

64

MULTI SENTRY

MCM / MSM / MCT / MST

68

MULTI GUARD

GMT

74

MULTI GUARD INDUSTRIAL

GMI

78

MPM / MPT

82

MHT

90

MHT UL

94

MIM

98

EMERGENCY solution CSS 1 h

C1T / C1M

124

EMERGENCY solution CSS 3 h

C3T / C3M

124

MASTER FC400

MFC

100

MASTER STATIC Bypass

MSB

102

MULTI SWITCH

MSW

106

MULTI SWITCH ATS

MTA

108

MASTER SWITCH STS 1ph

MMS

110

MASTER SWITCH STS 3ph

MTS

112

MASTER MPS MASTER HP MASTER HP UL MASTER INDUSTRIAL

www.riello-ups.com

17


RECOMMENDED PRODUCTS iPlug

Net Power

Vision

Vision Dual

Sentinel Pro

Sentinel Dual Low Power

SoHo Area

REFERENCES Italy

FEATURES

• • • •

Low energy consumption Small footprint Silent operation Advanced communication

APPLICATIONS

• Entertainment systems • Personal computers • xDSL connections • POS systems

• Consip • Carrefour • Dico / Coop

Sweden • Ikea

Germany

• Hilton Hotel • Mc Donald’s

UAE

• Royal Intern.

The SoHo market is becoming more and more important, covering the market sector that includes professionals, small businesses and freelance professionals working from home. No less important are domestic consumers, with the rise of entertainment devices and media centres requiring ever higher quality power supply and protection from interference and black-outs.

efficiency and lowest environmental impact, whilst still providing the best possible performance.

Low energy consumption

Silent operation

Reducing energy consumption has become an economical necessity as well as an environmental obligation. It is therefore essential to choose UPS that employ green technology such as those made by Riello UPS, designed to achieve the best energy

In the workplace and above all in the home, the silent operation of equipment is very important. This is why our UPS are equipped with a sophisticated microprocessor control system able to reduce the speed of the fans and switch

18

Small footprint The small footprint of Riello's UPS allow them to be easily installed anywhere in the office work space, without creating any interference with customer areas. There are also rack versions.

Portugal

• Intermarché

France

• Carrefour

Australia

• Toys “R” us • Lonely Planet

United Kingdom • ASDA

them off when not required. The entire Off-line range offers maximum silent operation thanks to the employment of high frequency components and the absence of moving parts, the noise level is equal to 0 dbA.

Advanced communication Riello UPS's UPS are equipped with USB and RS232 communication ports, allowing for full management and communication with the UPS to preserve data and make your IT systems secure. UPS with LI and OL technology are also equipped with expansion slots to house the various different communication options offered by Riello UPS.


RECOMMENDED PRODUCTS Multi Sentry

Master MPS

Master HP

Multi Guard

A UL

OD M R

Vision Dual

Sentinel Power

Datacenter Area

REFERENCES China

• China Mobile

FEATURES

• • • •

Extremely high availability Low energy consumption Small footprint Flexible configurations

APPLICATIONS

• Data centres • Server farms • Large databases • Telecommunications and IT • Banks and insurance companies

Data centres represent one of a company's most fundamental assets: a structure on which the entire organisation depends. This is why it is important to ensure these systems are both functional and reliable, starting from the correct electrical layout of the system and following precise quality criteria.

this level of availability can be achieved. The UPS must be versatile, compact and parallelable in order to provide the required flexibility; they should be able to adapt to all types of load, both inductive and capacitive, and should also be able to integrate with the other components in the system (e.g. electrical generators).

Availability

Energy consumption

According to the TIER standard, system availability should fall between 99.9 and 99.999%: downtime is not an option. Using high quality Riello UPS uninterruptible power supplies in a well-designed system,

Reducing energy consumption has become a necessity for all businesses as well as an environmental concern. It is therefore fundamental to choose a UPS supplier that offers green products designed to

Korea

• Telecom

Germany

• Sun Microsystems • German Government • Deutsche Bank • Allianz

India

• Samsung India Electronics • Sify

Italy • • • •

Poste Italiane Telecom Italia ENI Enel

Malaysia • CSF

Spain

• Globalswitch • Telefonica

United Kingdom

• ServerChoice • UniLever

provide the best energy efficiency and lowest environmental impact possible, with maximum performance. The Eco Energy Levels help identify the most highly efficient Riello UPS products.

Physical space It is critical to optimise the space available in data centres. Virtualising servers helps, but it is also useful to choose UPS with small footprints in order to avoid wasting space. The Multi Sentry and Master HP UPS ranges have some of the smallest footprints available on the market.

www.riello-ups.com

19


RECOMMENDED PRODUCTS Sentinel Pro

Sentinel Power Green

Multi Sentry

Master MPS

REFERENCES Austria

E-Medical Area

• Country Hospital Graz • Krankenhaus (LKH) Salzburg

France FEATURES

• Extreme protection for critical applications • High resilience • Compliant with specific standards

APPLICATIONS

• Back up of auxiliary power supply systems • Operating theatres • Hospital services

More and more sectors of the economy now rely on technology. Even medical and healthcare services now generally rely on digital technologies. Due to the critical nature of these applications, which are closely linked with personal well being, the services and infrastructure must be designed to ensure maximum levels of reliability and operating safety.

providing compatibility with: IP protection levels, input/output electrical isolation, the possibility of housing internal isolation transformers and auxiliary monitoring systems for electrical values. Riello UPS responds to all needs with products suited for all power and safety requirements connected with different applications.

SAFETY

RELIABILITY

According to the standards that apply to the sector, all medical equipment must adhere to stringent safety standards. based on the type of application, the UPS must ensure immunity from external influences,

In a medical context reliable services are critical and therefore the choice of UPS should favour the best technological solutions (on line dual conversion). These guarantee compatibility with all levels

20

• Clinique De La Sauvegarde Lyon • Tropical Medicine Centre - Marseille • Civil Hospital Lyon

Germany

• Klinikum Süd Nürnberg • Universitätklinikum Aachen

Italy

• Ospedale le Molinette - Turin • Ospedale Cardarelli Naples

Korea

• E-HWA University Hospital - Seoul

Spain

• Biomedical Research Park Barcelona

Sri Lanka

• Apollo Hospital - Colombo

of architecture aimed at increasing the availability and resilience of the system (parallelability and redundancy of power supply in accordance with the TIER standard). Electrical continuity cannot be guaranteed unless it is supported by suitable monitoring and control systems, which should be flexible and adaptable to the various systems and protocols installed in healthcare infrastructures. Riello UPS develops, tests and perfects its products as well as the different monitoring and control systems in-house, guaranteeing complete flexibility with different protocols and a rapid response to any interface problems.


RECOMMENDED PRODUCTS Sentinel Pro

Sentinel Power Green

Master MPS

Multi Guard Industrial

A UL

OD M R

SuperCaps UPS

Master Industrial

Industry Area REFERENCES Germany FEATURES

• Extremely high reliability and strength • Customisable • Compatible with long autonomy times • ModBus and Profibus support

Complex industrial installations are particularly critical and therefore require an exceptional level of resilience and reliability under all operating and environmental conditions. The UPS is a fundamental asset for guaranteeing service continuity and system safety. Riello UPS's industrial solutions have been protecting oil and gas infrastructures, power stations and other industrial installations for decades, making Riello UPS the industrial partner for every business in the sector.

RELIABILITY Operating continuity is fundamental in the industrial sector; a power shutdown or a breakdown in the supply of monitoring/

APPLICATIONS

• Oil & Gas • Power Generation, T&D • Water treatment • Instruments and process monitoring • Emergency systems

control information cannot be tolerated. This is why high quality Riello UPS uninterruptible power supplies are used: versatile, technologically advanced and suitable for operation in varied environmental conditions (temperature, humidity, vibrations, fluctuating power supplies, etc.).

STRENGTH In the industrial sector UPS are often required to provide a high level of compatibility with stringent mechanical standards (IP protection level > 21, protection against vibration, structural rigidity). In addition to this, in order to fulfil general requirements, the use of filters, isolated electrical connectors and

• Mannesmann • Audi • Adidas

India

• Metlon Industry

Italy

• Benetton Treviso • Pirelli Milano • Ilva • La Doria • Fincantieri

Spain

• Repsol

Sweden

• Ericsson • Saab

Russia • Ece

UK

• Glaxo Smith Kline • Corus

special wiring (halogen free, etc) is often required, as well as fastening components and systems that are highly resistant to mechanical stresses.

FLEXIBILITY AND CUSTOMISATION UPS Riello are flexible, i.e. they can be adapted to different power sources (single phase, three-phase, with or without neutral), they can be configured with isolation transformers not only at the output but also at the rectifier and bypass. They are compatible with various remote control communication protocols and can be customised to the specific requirements of any system.

www.riello-ups.com

21


RECOMMENDED PRODUCTS Master HP

Multi Guard Industrial

A UL

OD M R

Master MPS

Master FC400

REFERENCES Germany

• Munich airport • Hamburg railway station

Italy

• Underground railway Rome • Underground railway Turin • Malpensa Aiport

Transport Area

Spain FEATURES

• Protection for critical application • Adaptability to different environments • Flexibility of power supply • Extremely resilient The infrastructure used in the transport sector is increasingly technologically advanced and complex. At the same time however, it must also provide an exceptional level of resilience and reliability under all operating and environmental conditions. UPS and power continuity play a major role in guaranteeing continuity and excellence in the services provided.

FLEXIBILITY OF INSTALLATION Every application in the transport infrastructure sector has its own particular specifications and associated reference standards. It is therefore fundamental that the UPS are adaptable to different power sources (single phase, three-phase, with or without neutral),

22

APPLICATIONS

• Railway stations • Airports • Toll gates • Marinas

and compatible with various remote control communication protocols, which should be complete, rapid and effective.

GLOBAL STRENGTH The need to ensure service continuity requires high levels of compatibility with stringent mechanical standards (IP protection, vibrations, structural rigidity). The use of air filters, isolated electrical connectors and special wiring is often required in order to fulfil general requirements, as well as fastening components and systems that are highly resistant to mechanical stresses. Riello UPS is able to offer tailor-made solutions that satisfy the requirements of special standards or particular operating conditions.

• Barajas Airport, Madrid • High Speed Train A.V.E.

France

• CDG airport Paris • Underground railway Paris

United Arab Emirates

• Underground railway Dubai • Etihad Airway • Megacargo terminal Dubai

China

• Peking airport • Underground Railway Nanjing • Underground Railway Hong Kong

India

• Delhi underground railway

South Africa

• Johannesburg International Airport

RELIABILITY Operational continuity is strategic to the transport sector. Downtime with regards to power supply or monitoring/control information cannot be tolerated. Continuity can be guaranteed by using high quality UPS that are versatile, technologically advanced and parallelable, which are able to operate under critical environmental conditions (temperature, fluctuating power supplies, different types of load, etc.). Riello UPS with its range of transformer-less and transformer-based products is able to satisfy the most diverse and complex requirements to ensure operating continuity and reliability for users.


RECOMMENDED PRODUCTS Sentinel Pro

Sentinel Dual

Sentinel Power

Master MPS

High Power

CSS 1h e 3h

Emergency Area

FEATURES

• High reliability • Compliant with standard EN 50171 • Batteries with 10 year life (at 20°C) • Casing compliant with EN 60598-1 • Advanced diagnostics

Riello UPS centralised power supplies are designed for buildings subject to fire prevention safety standards. Designed and built in compliance with standard EN 50171 CPSS (Central Power Supply Systems) and other guidelines. These systems are designed mainly to provide emergency lighting in the event of a power blackout, however, they can also be used for other emergency systems, such as for example: • automatic fire prevention systems, • alarm units and emergency detection systems,

APPLICATIONS

• Hospitals • Railway stations • Stadiums and sports centres • Shopping centres • Schools • Public buildings

• smoke extraction equipment, • carbon monoxide detection systems, • specific safety systems in sensitive areas. The main features of Riello UPS solutions are summarised here: • Regulatory compliance • Autonomy of up to 3 h (and beyond on request) • Battery recharge time under 12 hours • Battery monitoring system • Galvanic isolation of input/output (optional)

REFERENCES Italy

• Juventus Stadium

Germany

• Allianz Arena

South Africa

• Ellispark Stadium • Loftus Stadium

Spain

• Barcelona Olympic Stadium

Czech Republic • Slavia Stadium Prague

• Advanced diagnostics (information on display panel) • Interface device to provide information remotely • High short circuit current. This is joined by Riello UPS's long term experience in emergency applications, with thousands of installations all over the world.

www.riello-ups.com

23



PRODUCT RANGE

www.riello-ups.com

25


VFD TYPE

UPS VFD

SOHO

iPlug 1:1 600-800 VA

5 USB plug

GS Nemko certified

Plug & Play installation

Highlights

• Compact • Versatile • Robust • Contemporary design • Auto restart • Battery swap 26

The iPlug series is the ideal solution for protecting household and small office systems. Its compact size and versatility (push-button operation, LED status panel and user replaceable batteries), make iPlug easy to install within a domestic environment to protect systems from surges and blackouts. When the mains fails, the load is powered from a pseudo-sine wave inverter, to provide sufficient runtime for computer system shutdown using PowerShield3 software,

which can be downloaded free from www.riello-ups.com

Versatile, robust and contemporary design The iPlug's compact and ergonomic design allow it to be easily installed in professional and domestic environments. iPlug is extremely versatile and its innovative cable management feature ensures a tidy, easy to manage installation.


Advanced communications PowerShield3 software allows for the safe shutdown of connected IT systems on mains power supply failure. PowerShield3 provides efficient and intuitive UPS management using bar chart displays for important operating information.

• Available with French (2P+T), British, Schuko and Italian outlets. • PowerShield3 supervision and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X and Sun Solaris • Plug and play function.

Auto restart

2-YEAR WARRANTY

Personal computers

250

LCD Monitors

70 200

Modems, TVs, DVD players, PlayStations, Hi-Fi systems, telephones, Faxes

50

Laser printers **

200

* Estimated average value. ** iPlug filtered output power supply is recommended.

Environmental protection ECO Line

Available sockets

AVAILABLE OPTIONS Software PowerShield3

Applications LCD monitors, personal computers, video terminals, printers, scanners and fax machines.

VA power rating *

Load type

Scanners, printers

The UPS automatically restarts upon the restoration of mains power after having shut down once the batteries have run out following a black out (Auto restart).

With energy savings in mind, the iPlug range features a shut-off button to reduce energy consumption during periods of prolonged inactivity.

configurator for model selection

SCHUKO SOCKET

FRENCH SOCKET

ITALIAN SOCKET

BRITISH SOCKET

CEE 7/7P

CEE 7/5

CEI 23/16

BS1363A

Features • Compact and ergonomic • 5 sockets protected against black-outs • 3 sockets protected against overvoltage for the supply of loads with larger absorption loads e.g laser printers • Ability to switch on the UPS without a mains power supply (Cold Start) • User replaceable batteries (Battery Swap) • USB interface • Floor-standing or desktop installation • Power-supply cable included • Built-in short circuit protection • Auto restart (when mains power is restored, after discharge of the batteries) • GS/Nemko safety seal

Details FILTERED SOCKETS: PROTECTED AGAINST OVERVOLTAGE ONLY

SOCKETS WITH UPS PROTECTION (NO BREAK IN POWER IF MAINS FAILS)

IEC SOCKETS WITH UPS PROTECTION

USB COMMUNICATION PORT

SAFETY FUSE

www.riello-ups.com

27


MODELS POWER

IPG 600

IPG 800

600 VA/360 W

800 VA/480 W

INPUT Nominal voltage

220-240 Vac

Input voltage tolerance frequency

230 Vac (+20/-25%)

Frequency

50/60 Hz with automatic selection

OUTPUT Voltage during mains operation

230 Vac (+20/-25%)

Voltage during battery operation

230 Vac (+/- 10%)

Frequency during battery operation

50 or 60 Hz (+/- 1%)

Waveform

Pseudo Sinusoidal

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

6-8 hours

OTHER FEATURES Net weight (kg) Gross weight (kg)

4.1

4

4.4

Dimensions (WxDxH) (mm)

185 x 313 x 99

Packaging dimensions (WxDxH) (mm)

260 x 380 x 140

Protections Communications Output sockets

Excessive low battery - overvoltage - short circuit USB 6 sockets (Schuko or Italian or French or British) + 2 IEC 320 C13

Standards

EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3 EN 62040-2 and Directive 2004/108 EC

Certificates

CE; GS/NEMKO on Schuko version

Operating temperature Colour Altitude and relative humidity Equipment provided

28

3.7

0 째C / +40 째C Black 6000 m max altitude, < 95% non-condensing power cable, user guide


www.riello-ups.com

29


VFD TYPE

UPS VFD

SOHO

iDialog 1:1 400-1600 VA

5 USB plug

Plug & Play installation

Highlights

• Compact • Silent operation • Contemporary design • Auto restart • Low power consumption

The iDialog range is the ideal solution for protecting PCs and peripherals in the home and office. iDialog is easy to install and economic to run for protecting: • IT equipment such as PCs, Media Centres and peripherals, TVs, Home Cinema systems, Satellite and Digital Terrestrial Receivers and DVD recorders and players; • xDSL modems and routers; • Small home appliances.

Silent operation The UPS is silent in operation (0dBA) thanks to its use of a fan-less design and high frequency components.

30

Advanced communications PowerShield3 software allows for the safe shutdown of connected IT systems on mains power supply failure. PowerShield3 provides efficient and intuitive UPS management using bar chart displays for important operating information.

Auto restart The UPS automatically restarts when the mains power supply is restored, after auto power.

ECO Line environmental protection With energy savings in mind, the iDialog range features a shut-off button to reduce


MODELS POWER

IDG 400

IDG 600

IDG 800

IDG 1200

IDG 1600

400 VA/240 W

600 VA/360 W

800 VA/480 W

1200 VA/720 W

1600 VA/960 W

INPUT Nominal voltage

220-240 Vac

Input voltage tolerance frequency

230 Vac (+20/-25%)

Frequency

50/60 Hz with automatic selection

OUTPUT Voltage during mains operation

230 Vac (+20/-25%)

Voltage during battery operation

230 Vac (+/- 10%)

Frequency during battery operation

50 or 60 Hz (+/- 1%)

Waveform

Pseudo Sinusoidal

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

6-8 h

OTHER FEATURES Net weight (kg)

3.2

3.4

6.6

6.9

Gross weight (kg)

3.7

4.1

8.1

8.6

Dimensions (WxDxH) (mm)

90 x 232 x 192

93 x 310 x 270

Packaging dimensions (WxDxH) (mm)

138 x 300 x 278

170 x 400 x 370

Protections

Excessive low battery - overvoltage - short circuit

Communications

USB

USB + RS232

4 IEC 320 C13

6 IEC 320 C13

Output sockets Standards

EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3 EN 62040-2 and Directive 2004/108 EC

Certificates

CE

Operating temperature

0 °C / +40 °C

Colour Altitude and relative humidity Standard equipment

energy consumption during periods of prolonged inactivity.

Features • Reduced energy consumption and 99% efficiency • Maximum reliability and protection of PCs thanks to PowerShield3 monitoring and shutdown software, which can be downloaded free at www.riello-ups.com • Can be installed on PCs with Windows 8, 7, 2008, Vista, 2003, Xp, Linux, Mac OSX and Sun Solaris operating systems • Small size: With its compact shape, iDialog can be placed anywhere on the desk or in the home.

Black 6000 m max altitude, <95% non-condensing 2 output power supply cables, 1 USB cable, user manual

• Silent: iDialog is also suitable for protecting your non-professional digital equipment such as home cinema systems, satellite and digital terrestrial receivers and DVD players/recorders.

2-YEAR WARRANTY

Details IDG 400 IDG 600 IDG 800

IDG 1200 IDG 1600

SOCKETS WITH UPS PROTECTION

(NO BREAK IN POWER IF MAINS FAILS)

SERIAL PORT RS232 USB COMMUNICATION PORT

SAFETY FUSE

AVAILABLE OPTIONS Software PowerShield3

FILTERED SOCKETS: PROTECTED AGAINST OVERVOLTAGE ONLY

MAINS INPUT PLUG

www.riello-ups.com

31


VI

TYPE

LINE INTERACTIVE

SOHO

Net Power 1:1 600-2000 VA

5 USB plug

Plug & Play installation

Highlights

• Automatic Voltage Regulation (AVR) • Advanced communications • Automatic battery test

The Net Power series is available in 6002000 VA models with digital technology: when available the load is supplied from the mains power supply, which is amplitudestabilised by the automatic voltage regulator (AVR) and filtered against overvoltages by EMI filters. When the mains fails, the load is powered from a pseudo-sine wave inverter, to provide sufficient runtime for computer system shutdown using PowerShield3 software, which can be downloaded free from www.riello-ups.com

Features • Stabilisation and filtering of the mains power supply using AVR and EMI filters for the suppression of atmospheric disturbances 32

• Ability to switch on the UPS in the absence of mains power (Cold Start) • High reliability with built-in battery test • Auto restart (when mains power is restored, after discharge of the batteries) • Supplied with two IEC cables for powering the loads.

Advanced communications • Advanced multi-platform communications for all operating systems and network environments: PowerShield3 supervision and shutdown software for Windows operating systems 7, 2008, Vista, 2003, XP, Linux, Mac OS X and Sun Solaris • Standard USB interface, RS232 on models 1000 - 1500 - 2000.

2-YEAR WARRANTY


MODELS POWER

NPW 600

NPW 800

NPW 1000

NPW 1500

NPW 2000

600 VA/360 W

800 VA/480 W

1000 VA/600 W

1500 VA/900 W

2000 VA/1200 W

INPUT Nominal voltage

220-230-240 Vac

Input voltage tolerance

230 Vac (±25%)

Frequency

50/60 Hz with automatic selection

OUTPUT Voltage during mains operation

230 Vac (-8%, +10%)

Voltage during battery operation

230 Vac (+/- 5%)

Frequency during battery operation

50 or 60 Hz (+/- 0.5%)

Battery waveform

Pseudo sinusoidal

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

6-8 h

2-4 h

OTHER FEATURES Net weight (kg)

4.3

4.9

8

11.1

11.5

Gross weight (kg)

5.6

6.3

10

13.5

14

Dimensions (WxDxH) (mm)

100 x 287 x 142

146 x 350 x 160

146 x 397 x 205

Packaged dimensions (WxDxH) (mm)

140 x 332 x 220

195 x 440 x 250

230 x 480 x 280

Protections Communications Output sockets

Excessive low battery - overvoltage - short circuit USB

USB + RS232

4 IEC 320 C13 sockets

6 IEC 320 C13 sockets

Standards

EN 62040-1-1 and Directive 2006/95/EC; EN 62040-2 category C2 and Directive 2004/108 EC

Certificates

CE

Operating temperature

0 °C / +40 °C

Colour

Black

Altitude and relative humidity

6000 m max altitude, <95% non-condensing

Standard equipment

Available options Software PowerShield3

2 cables for powering loads; user manual

Details

NPW 600 NPW 800

NPW 1000

NPW 1500 NPW 2000 SERIAL PORT RS232

USB COMMUNICATION PORT

OUTPUT SOCKETS

MAINS INPUT PLUG

www.riello-ups.com

33


VI

TYPE

LINE INTERACTIVE

SOHO

Vision 1:1 800-2000 VA

6

USB plug

Hot swap battery

Plug & Play installation

• Versatility

The Vision range is available in models from 800 VA to 2000 VA with sinusoidal digital technology. The Vision range, with its advanced communications and connectivity options, is the ideal solution for installations requiring superior protection and versatility in the power supply system. Vision is the ideal solution for the protection of peripheral network devices, servers, and network backup systems.

• LCD display

Superior protection

Highlights

• Superior protection • Compact and contemporary design • High availability

• Automatic Voltage Regulation (AVR)

34

The Vision range uses Line Interactive technology and provides a sinusoidal output. This technology provides efficiency levels of 98% and therefore reduced energy consumption. It also ensures a high level of protection against mains power disturbances. The automatic voltage regulator (AVR)

provides protection from surges, overvoltages and undervoltages, without battery intervention. Reduced battery usage ensures that the battery set is 100% available for mains power supply failures and is able to provide greater autonomy. EMI filters then provide further protection from voltage surges and transients. When the mains power supply fails, the load is powered by the inverter and receives a perfectly sinusoidal supply for maximum power continuity and reliability. With energy savings in mind, the Vision range features a shut-off button to reduce energy consumption to zero during periods of prolonged inactivity.

High availability An EnergyShare socket allows loadshedding and the shutdown of less sensitive


peripheral devices to extend battery runtime for critical loads. “Hot Swap” batteries can be removed via the front panel for easy and safe UPS maintenance. Battery test facility to detect deteriorating battery performance. Deep discharge protection to reduce battery ageing.

Versatility Cold Start function to allow the UPS to power up with no mains power supply present.

LCD display Vision models have a backlit LCD display providing UPS status information, load and battery performance.

Advanced communications • Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, VMWare ESX and other Unix operating systems • USB or RS232 serial port interface (selectable) • Expansion slot for interface boards • Status, measurements, alarms and input, output and battery parameters available on LCD display.

Features • EnergyShare socket • Ability to switch on the UPS in the absence of mains power (Cold Start) • Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap) • Maximum reliability and protection of PCs thanks to PowerShield3 monitoring and shutdown software, which can be downloaded free at www.riello-ups.com • Fully configurable using UPS Tools configuration software • Highly reliable batteries (automatic and manually-activated battery test) • Built-in short circuit protection • Auto restart (when mains power is restored, after discharge of the batteries) • GS/Nemko safety seal

Available options Software PowerShield3 PowerNetGuard

MULTICOM 351 MULTICOM 352 MULTICOM 372 MULTICOM 382 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302

Details VST 800 VST 1100

VST 1500 VST 2000

USB SERIAL RS232

slot for communications boards SAFETY FUSE OUTPUT SOCKETS

2-YEAR WARRANTY

INPUT PLUG energyshare

www.riello-ups.com

35


MODELS

VST 800

VST 1100

VST 1500

VST 2000

POWER

800 VA/640 W

1100 VA/880 W

1500 VA/1200 W

2000 VA/1600 W

INPUT Nominal voltage

220 - 230 - 240 V selectable

Voltage tolerance

162 V - 290 V

Frequency

50/60 Hz with automatic selection

Frequency tolerance

±5%

OUTPUT Nominal voltage

220 - 230 - 240 V selectable

Frequency

50 or 60 Hz with automatic selection

Waveform

Sinusoidal

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

4-6 h

OTHER FEATURES Net weight (kg)

10.5

11.3

16.5

18.5

Gross weight (kg)

12.2

13

18.4

20.4

Dimensions (WxDxH) (mm)

120 x 443 x 247

160 x 443 x 247

Packaging dimensions (WxDxH) (mm)

208 x 530 x 342

235 x 540 x 354

Protections Communications

Overload - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / RS232 / slot for communications interface

Input plugs Output sockets Standards

6 IEC 320 C13 EN 62040-1-1 and Directive 2006/95/EC EN 62040-2 and Directive 2004/108 EC

Operating temperature

0 °C / +40 °C

Storage temperature

-15 °C / 45 °C

Colour Relative humidity Noise

36

1IEC 320 C14 4 IEC 320 C13

Black <95% non-condensing < 40 dBA


www.riello-ups.com

37


VI

TYPE

SOHO

DATACENTER

LINE INTERACTIVE

Dialog Vision 1:1 500-1100 VA

5 USB plug

Hot swap battery

Plug & Play installation

Highlights

• Superior protection • High availability • Versatility • LCD display • Automatic voltage regulation (AVR)

The Dialog Vision range is available in models from 500 VA to 1100 VA with sinusoidal digital technology. The Dialog Vision range, with its advanced communications and connectivity options, is the ideal solution for installations requiring superior protection and versatility in the power supply system. Dialog Vision is the ideal solution for the protection of peripheral network devices, servers, and network back-up systems.

Superior protection The Dialog Vision range uses Line Interactive technology and provides a sinusoidal output

38

voltage. This technology provides efficiency levels of 98% and therefore reduced energy consumption. It also ensures a high level of protection against mains power disturbances. The automatic voltage regulator (AVR) provides protection from surges, overvoltages and undervoltages, without battery intervention. Reduced battery usage ensures that the battery set is 100% available for mains power supply failures and is able to provide greater autonomy. EMI filters then provide further protection from voltage surges and transients.


When the mains power supply fails, the load is powered by the inverter and receives a perfectly sinusoidal supply for maximum power continuity and reliability.

High availability An EnergyShare socket allows loadshedding and the shutdown of less sensitive peripheral devices to extend battery runtime for critical loads. “Hot Swap” batteries can be removed via the front panel for easy and safe UPS maintenance. Battery test facility to detect deteriorating battery performance. Deep discharge protection to reduce battery ageing.

VMWare ESX and other Unix operating systems • USB or RS232 serial port interface (selectable) • Expansion slot for interface boards • Status, measurements, alarms and input, output and battery parameters available on LCD display.

Features • EnergyShare socket • Ability to switch on the UPS in the absence of mains power (Cold Start) • User-replaceable battery set (Battery Swap)

• USB and RS232 interface • Slot for communications boards • Maximum reliability and protection of PCs thanks to PowerShield3 monitoring and shutdown software, which can be downloaded free at www.riello-ups.com • Highly reliable batteries (automatic and manually-activated battery test) • Built-in short circuit protection • Auto restart (when mains power is restored, after discharge of the batteries) • Emergency power off contact (EPO).

2-YEAR WARRANTY

Versatility Cold Start function to allow the UPS to power up with no mains power supply present.

Display Vision models have a backlit LCD display providing UPS status information, load and battery performance.

Advanced communications • Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux,

DETAILS DVR 500/800/1100

IEC MAINS INPUT PLUG TELEPHONE LINE / MODEM PROTECTION EPO USB PORT RS232 SERIAL INTERFACE IEC OUTPUT SOCKETS

OPTIONS Software PowerShield3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352

MULTICOM 372 MULTICOM 382 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 PRODUCT ACCESSORIES Universal rails for installation in rack cabinets

www.riello-ups.com

39


MODELS POWER

DVR 500

DVR 800

DVR 1100

500 VA/350 W

800 VA/540 W

1100 VA/740 W

INPUT Nominal voltage

230 Vac (200, 208, 220, 240 V selectable)

Voltage tolerance

160 V - 294 V

Frequency

50/60 Hz with automatic selection

Frequency tolerance

±5%

OUTPUT Nominal voltage

230 Vac (200, 208, 220, 240 V selectable)

Frequency

50 or 60 Hz with automatic selection

Waveform

Sinusoidal

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

4-6 h

OTHER FEATURES Net weight (kg)

12

13.5

15.6

Gross weight (kg)

16

18

20

Dimensions (WxDxH) (mm) Packaged dimensions (WxDxH) (mm) Protections Communications

605 x 623 x 200 Overload - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / RS232 / slot for communications interface

Input plugs

1 IEC 320 C14

Output sockets

4 IEC 320 C13

Standards

EN 62040-1-1 and Directive 2006/95/EC; EN 62040-2 and Directive 2004/108 EC

Operating temperature

0 °C / +40 °C

Storage temperature

-15 °C / 45 °C

Colour Relative humidity Noise

40

19” x 460 x 1U

Black <95% non-condensing < 50 dBA


www.riello-ups.com

41


VI

TYPE

SOHO

LINE INTERACTIVE

DATACENTER

Vision Dual 1:1 1100-3000 VA

6

USB plug

Energy share

Hot swap battery

Plug & Play installation

Highlights

• Automatic Voltage Regulation (AVR) • Superior protection • High efficiency • High availability • Versatility • Advanced communications 42

The Vision Dual range (tower and rack), includes models from 1100 VA to 3000 VA with sinusoidal digital technology. The Vision Dual range, with its advanced communications and connectivity options, is the ideal solution for installations requiring superior protection and versatility in the power supply system. Vision Dual is the ideal solution for the protection of peripheral network devices, conventional or rack servers, and network back-up systems. Vision Dual has a practical, modern design and includes several performance advantages over traditional on-line UPS. All developed by the Riello UPS research and development team.

The UPS provides efficiency levels of 98% and therefore reduced energy consumption. It has an output power factor of 0.9.

Superior protection The automatic voltage regulator (AVR) provides protection from surges, overvoltages and undervoltages, without battery intervention. Reduced battery usage ensures that the battery set is 100% available for mains power supply failures and is able to provide greater autonomy. EMI filters then provide further protection from voltage surges and transients. When the mains power supply fails, the load is powered by the inverter and receives a perfectly sinusoidal supply for maximum power continuity and reliability.


High availability

Versatility

An EnergyShare socket allows loadshedding and the shutdown of less sensitive peripheral devices to extend battery runtime for critical loads. “Hot Swap” batteries can be removed via the front panel for easy and safe UPS maintenance. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models (versions 2200 and 3000) fitted with more powerful battery chargers. Battery test facility to detect deteriorating battery performance. Deep discharge protection to reduce battery ageing.

Vision Dual can be installed as a tower or in 19” rack cabinets. The display panel can be easily removed and rotated to suit the type of installation required. Vision Dual is equipped with an emergency power off (EPO) contact that allows for remote shutdown in emergency situations. Cold Start function to allow the UPS to power up with no mains power supply present. Vision Dual models have a backlit LCD display providing UPS status information, load and battery performance.

and shutdown software included, with SNMP agent, for Windows operating systems 7, 2008, Vista, 2003, XP, Mac OS X, Sun Solaris, Linux, VMWare ESX and other Unix operating systems • USB or RS232 serial port interface (selectable) • Expansion slot for SNMP agent interface boards • Status, measurements, alarms and input, output and battery parameters available on LCD display.

Advanced communications

2-YEAR WARRANTY

1. REMOVE THE DISPLAY PANEL

for all operating systems and network environments: PowerShield3 monitoring

• Advanced multi-platform communications

2. ROTATE THE DISPLAY PANEL AND INSERT IT INTO POSITION

3. ROTATE THE UPS BY 90º

4. ATTACH THE RACK SUPPORTS

90°

90°

DETAILS VSD 1100/1500

BBX

INPUT SOCKET

INPUT THERMAL PROTECTION EMERGENCY SWITCH DEVICE (ESD) OUTPUT SOCKETS BATTERY EXPANSION SOCKET

VSD 2200/2200ER 3000/3000 ER

INPUT PLUG USB PORT

RS232 SERIAL

Software PowerShield3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 372 MULTICOM 382

BATTERY BOX MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 Manual Bypass 16 A Manual Bypass 16 A Rack Automatic Bypass 16 A Automatic Bypass 16 A Rack

BB sDH 72-A3 BB SDH 72-M1

modeLS

BB

Dimensions (mm)

450

OPTIONS

5 62 87

PRODUCT ACCESSORIES Universal rails for installation in rack cabinets

www.riello-ups.com

43


MODELS POWER

VSD 1100

VSD 1500

VSD 2200

VSD 2200 ER

VSD 3000

VSD 3000 ER

1100 VA/990 W 1500 VA/1350 W 2200 VA/1980 W 2200 VA/1760 W 3000 VA/2700 W 3000 VA/2400 W

INPUT Nominal voltage

220-230-240 Vac

Voltage range without battery intervention

162 Vac < Vin < 290 Vac

Maximum permitted voltage

300 V

Nominal frequency

50 or 60 Hz ±5Hz

Frequency range

50 Hz ± 5% / 60 Hz ± 5%

Power factor

> 0.98

Current distortion

≤7%

OUTPUT Voltage distortion with linear load / with non-linear load

< 3% / < 8%

Frequency

Selectable: 50 Hz or 60 Hz or self-learning

Waveform

Sinusoidal

Current crest factor

2.5 : 1

Efficiency ECO and Smart Active Modes

98.5%

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

2-4 hours

OVERLOAD TIMES 100% < Load < 110%

5 minutes

110% < Load < 150%

10 seconds

Load > 150%

1 second

OTHER FEATURES Net weight (kg) Gross weight (kg) Dimensions (WxDxH) (mm) Packaged dimensions (WxDxH) (mm)

16.5

17.5

28

15.5

31.5

16.5

20

21

33

20.5

36.5

21.5

87 x 450 x 425 (2U x 19” x 425)

87 x 450 x 625 (2U x 19” x 625)

240 x 500 x 600

240 x 600 x 760

Protection against overvoltages Protections Communications

Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / DB9 with RS232 and contacts / Slot for communications interface

Input plugs

1 iEC 320 C14

1 iEC 320 C20

Output sockets

8 iEC 320 C13

8 iEC 320 C13 + 1 iEC 320 C19

Standards Operating temperature Relative humidity Colour Noise level at 1 m Standard equipment provided

44

300 joules

Safety: EN 62040-1 and Directive 2006/95/EL; EMC: EN 62040-2 category C2 and Directives 2004/108/EL 0 °C / +40 °C <95% non-condensing Black < 40 dBA Power cable, serial cable, USB cable, safety manual, quick start guide, user manual on CD-ROM


www.riello-ups.com

45


VFI TYPE

SOHO

E-MEDICAL

INDUSTRY

EMERGENCY

ONLINE

Sentinel Pro 1:1 700-3000 VA

6

USB plug

Supercaps UPS

GS Nemko certified

Plug & Play installation

Highlights

• Operating flexibility • Emergency function • Battery optimisation • Runtime expandability • Low noise level

46

Sentinel Pro has a unique and modern design and improved performance developed by the Riello UPS research and development team. Sentinel Pro uses on-line double conversion technology, resulting in the highest levels of reliability and maximum protection for critical loads such as servers, and IT and voice/data applications. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models fitted with more powerful battery chargers. The front display panel has been entirely redesigned, adding an LCD display that

shows the input and output voltages, battery readings and UPS operating status information. The inverter and the microprocessor control stage has been completely redesigned to provide increased efficiency and greater configuration options. Maximum expandability: the Sentinel Pro is supplied as standard with a USB port and an expansion slot for protocol conversion or relay contacts boards. With energy savings in mind, Sentinel Pro is also fitted with a shut-off button to reduce energy consumption to zero during prolonged periods of inactivity (ECO LINE). Sentinel Pro is available in 700 VA, 1000 VA, 1500 VA, 2200 VA and 3000 VA models.


Operating flexibility Different operating modes that can be programmed according to on user requirements and the load to be powered have been introduced in order to reduce energy consumption. • On line: maximum load protection and output voltage waveform quality • Economy Mode: the UPS uses line interactive technology, with the load powered by the mains, reducing consumption and thus improving efficiency (up to 98%). • Smart Active Mode: the UPS automatically selects on-line or line interactive operation, depending on the quality of the mains supply, checking the number, frequency and type of disturbances present. • Stand by Off (emergency): The UPS supplies the load only when the mains fails. The inverter begins working with a progressive start-up sequence to prevent inrush currents. • Frequency converter operation (50 or 60 Hz).

Emergency function This configuration ensures the operation of emergency systems that must be supplied in the event of a mains power failure, such as emergency lighting, fire detection/ extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive startup (Soft Start) in order to prevent overload. Sentinel Pro is compliant for installation in medium-voltage transformer rooms in accordance with applicable legislation, for the power supply with reserve charge of medium-voltage coils.

Battery optimisation

Low noise level

The Sentinel Pro range has a deep discharge protection device to optimise battery life. Periodically the UPS carries out a battery efficiency test (which can also be manually activated); its wide input voltage tolerance range helps to reduce battery usage and maintain performance over time.

Thanks to the use of high frequency components and load-based fan speed control, the noise produced by the UPS is less than 40 dBA.

Runtime expandability Optional battery extension packs can be connected to increase UPS runtime. In addition the Sentinel Pro range includes ER versions with no internal batteries and more powerful battery chargers for longer runtimes.

Features • Filtered, stabilised and reliable voltage: double conversion on-line technology (VFI compliant with IEC 62040-3) with filters for the suppression of atmospheric disturbances. • High overload capability (up to 150%) • Programmable Auto-restart when mains is restored • Battery start-up (cold start)

DETAILS SEP 2200 SEP 2200 ER

SEP 3000 SEP 3000 ER USB PORT

SEP 700 SEP 1500

SEP 1000 SEP 1000 ER

SERIAL INTERFACE

COMMUNICATIONS SLOT

BATTERY EXPANSION CONNECTOR

OUTPUT SOCKETS

INPUT SOCKET

www.riello-ups.com

47


• Multi-platform communication for all operating systems and network environments: PowerShield3 supervision and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, VMware ESX and other Unix operating systems. • UPS Tools configuration and customisation software supplied as standard • RS232 serial port and opto-isolated contacts • USB port • Slot for communications boards.

2-YEAR WARRANTY

48

Software PowerShield3 PowerNetGuard

MULTICOM 382 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 Manual Bypass 16 A Automatic Bypass 16 A

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 372

BATTERY BOX MODELS

BB SEP 36-A3 / BB SEP 36-M1

BB SEP 72-A3 / BB SEP 72-M1

333

Advanced communications

OPTIONS

Dimensions (mm)

235

• Power factor correction (UPS input power factor, close to 1) • Wide input voltage tolerance range (from 140 V to 276 V) without battery intervention. • Runtime extendable up to several hours • Fully configurable using UPS Tools configuration software • Highly reliable batteries (automatic and manually-activated battery test) • High level of UPS reliability (total microprocessor control) • Low impact on the mains (sinusoidal take up).

BB 15 8

2 42

BB 19 0

6 44


MODELS POWER

SEP 700

SEP 1000 SEP 1000 ER

SEP 1500

SEP 2200 SEP 2200 ER SEP 3000 SEP 3000 ER

700 VA/560 W

1000 VA/800 W

1500 VA/1200 W

2200 VA/1760 W

3000 VA/2400 W

INPUT Nominal voltage

220-230-240 Vac

Voltage range without battery intervention

140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD

Maximum permitted voltage

300 Vac

Nominal frequency

50/60 Hz

Frequency range

50 Hz ± 5% / 60 Hz ± 5%

Power factor

> 0.99

Current distortion

≤7%

BYPASS Voltage tolerance

180 - 264 Vac

Frequency tolerance

Frequency selected (from ±1.5Hz to ±5Hz configurable)

OUTPUT Voltage distortion with linear load / with non-linear load

< 2% / < 4%

Frequency

Selectable: 50 Hz or 60 Hz or self-learning

Static variation

± 1%

Dynamic variation

≤ 5% in 20 msec.

Waveform

Sinusoidal

Current crest factor

3:1

Efficiency ECO and Smart Active Modes

98%

BATTERIES Type Recharge time

VRLA AGM maintenance-free lead based; Supercaps 2-4 hours

N.A.

2-4 hours

N.A.

2-4 hours

N.A.

OVERLOAD TIMES 100% < Load < 110%

2 minutes

110% < Load < 150%

5 seconds

Load > 150%

1 second

OTHER FEATURES Net weight (kg)

10,9

13,3

7

14,8

25,6

10,6

28

14

Gross weight (kg)

12,5

14,9

8,6

15,5

28,8

13,8

31,2

17,2

Dimensions (WxDxH) (mm)

158 x 422 x 235

190 x 446 x 333

Packaging dimensions (WxDxH) (mm)

245 x 500 x 340

325 x 585 x 470

Protection against overvoltage Protections Communications Input plugs Output sockets Standards Operating temperature Relative humidity Colour Noise level at 1 m Standard equipment provided

300 joules Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / DB9 with RS232 and contacts / Slot for communications interface 1 iEC 320 C14

1 iEC 320 C20

4 iEC 320 C13

8 iEC 320 C13

8 iEC 320 C13 + 1 iEC 320 C19

Safety: EN 62040-1 and Directive 2006/95/EL; EMC: EN 620040-2 category C2 and Directives 2004/108/EL 0 °C / +40 °C < 95% non-condensing Black < 40 dBA Power cable, IEC-IEC cable, USB cable, safety manual, quick start guide

www.riello-ups.com

49


VFI TYPE

Sentinel Dual

SOHO

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

Low Power

1:1 1-3 kVA

6

USB plug

Energy share

Hot swap battery

Plug & Play installation

Highlights

• Simplified installation • Installation versatility • Reduced running costs • Runtime expandability • Low noise level

50

Sentinel Dual is the new range of high density double conversion online UPS, suitable for powering a wide range of devices such as servers, storage systems, telephony - VoIP equipment, network and medical systems as well as industrial applications. It is also ideal for powering and protecting Blade Server systems with high input power factor. At only 2U, Sentinel Dual is ideal for 19” rack cabinet installations. Sentinel Dual has a practical, modern design and includes several performance advantages over traditional on-line UPS. All developed by the Riello UPS research and

development team. The newly-designed inverter is one of the best energy conversion systems on the market, with a 0.9 output power factor and 92% operating efficiency in on-line mode. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models fitted with more powerful battery chargers. With energy savings in mind, Sentinel Dual is also fitted with a shut-off button to reduce energy consumption to zero during prolonged periods of inactivity.


1. REMOVE THE DISPLAY PANEL

2. ROTATE THE DISPLAY PANEL AND INSERT IT INTO POSITION

3. ROTATE THE UPS BY 90º

4. ATTACH THE RACK SUPPORTS

90°

90°

Simplified installation • Sentinel Dual can be installed as a tower or in 19” rack cabinets, by simply removing and rotating the display panel • Low noise (<40 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan. • Operation guaranteed up to 40°C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures) • On Sentinel Dual models, the output sockets can be programmed to disconnect less critical loads during blackouts (EnergyShare function).

Installation versatility Sentinel Dual can be used in a tower or rack format, by simply turning the display and adding the supplied handles or optional runners.

Reduced running costs The UPS is highly flexible and easy to configure. Programmable functions can be set via software or manually via the front display panel. Sentinel Dual can be configured in the following operating modes: • On Line, maximum load protection and output voltage waveform quality • ECO Mode, to increase efficiency (up to to 98%); allows you to select Line Interactive technology • Smart Active, the UPS automatically decides the operating mode based on the mains power quality • Emergency, the UPS can be selected to function only when the mains power supply fails (emergency only mode) • Frequency converter operation (50 or 60 Hz).

Advanced communications Sentinel Dual offers maximum flexibility for integration with all types of communication systems.

• Multi-platform communication for all operating systems and network environments: PowerShield3 supervision and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, VMware ESX and other Unix operating systems. • UPS Tools configuration and customisation software supplied as standard • RS232 serial port and opto-isolated contacts • USB port • Slot for communications boards such as Modbus/Jbus, TCP/IP-SNMP and relay contacts.

Emergency function This configuration ensures the operation of emergency systems that must be supplied in the event of a mains power failure, such as emergency lighting, fire detection/ extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive start-up (Soft Start) in order to prevent overload. Sentinel Dual is compliant for installation in medium-voltage transformer rooms in accordance with applicable legislation, for the power supply with reserve charge of medium-voltage coils.

High quality output voltage • Even with non-linear loads (IT loads with a crest factor of up to 3:1) • High short circuit current on bypass • High overload capacity: 150% by inverter (even with mains failure) • Filtered, stabilised and reliable voltage (On-line double conversion technology (VFI compliant with EN62040-2 class C2) with filters for the suppression of atmospheric disturbances • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

High battery reliability • Automatic and manual battery test • Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap) • Unlimited extendible runtime using matching battery boxes.

Low noise level Thanks to the use of high frequency components and load-based fan speed control, the noise produced by the UPS is less than 40 dB.

Other features • Output voltage can be selected via software (220-230-240 V) • Auto-restart when mains power is restored (programmable via software) • Stand-by on bypass: when the machine is switched off, it automatically goes into bypass and battery charge mode • Minimum load switch-off • Battery discharge warning • Start-up delay • Total microprocessor control • Automatic bypass without interruption • Status, measurements and alarms available on standard backlit display • UPS firmware updating via PC • Input protection via resettable thermal switch (versions up to 1500VA) • Back-feed protection standard: to prevent energy from being fed back to the network • Manual switching to bypass.

2-YEAR WARRANTY

www.riello-ups.com

51


DETAILS INPUT SOCKET

SDH 1000

SDH 1500

INPUT THERMAL PROTECTION

output sockets USB PORT RS232 SERIAL

SDH 2200/2200ER 3000/3000 ER

BB

BATTERY EXPANSION SOCKET

INPUT PLUG EMERGENCY SWITCH DEVICE (ESD)

OPTIONS Software PowerShield3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301

MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 372 MULTICOM 382 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL

RTG 100 Manual Bypass 16 A Manual Bypass 16 A Rack Automatic Bypass 16 A Automatic Bypass 16 A Rack PRODUCT ACCESSORIES Universal rails for installation in rack cabinets

BATTERY BOX

BB

87

52

5 42

BB SDH 72-A3 / BB SDH 72-M1

BB

450

Dimensions (mm)

BB SDH 36-A3 / BB SDH 36-M1

450

MODELS

5 62

87


MODELS POWER

SDH 1000

SDH 1500

SDH 2200

SDH 2200 ER

SDH 3000

SDH 3000 ER

1000 VA/900 W 1500 VA/1350 W 2200VA/1980 W 2200VA/1760 W 3000 VA/2700 W 3000 VA/2400 W

INPUT Nominal voltage

220-230-240 Vac

Voltage range without battery intervention

140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD

Maximum permitted voltage

300 V

Nominal frequency

50/60 Hz ±5Hz

Frequency range

50 Hz ± 5% / 60 Hz ± 5%

Power factor

> 0.98

Current distortion

≤7%

BYPASS Voltage tolerance

200 - 253 Vac

Frequency tolerance

Frequency selected (from ±0.5Hz to ±5Hz configurable)

OUTPUT Voltage distortion with linear load / with non-linear load

< 2%

Frequency

Selectable: 50 Hz or 60 Hz or self-learning

Static variation

± 1%

Dynamic variation

≤ 5% in 20 msec.

Waveform

Sinusoidal

Current crest factor

3:1

Efficiency ECO and Smart Active Modes

98%

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

2-4 hours

OVERLOAD TIMES 100% < Load < 110%

1 minute

110% < Load < 150%

4 seconds

Load > 150%

0.5 seconds

OTHER FEATURES Net weight (kg) Gross weight (kg) Dimensions (WxDxH) (mm) Packaged dimensions (WxDxH) (mm)

17.5

18

30.5

15

31

15

21

21.5

35

19.5

35.5

19.5

(T- 87 x 425 x 450) (R- 19” x 425 x 2U)

(T- 87 x 625 x 450) (R- 19” x 625 x 2U)

550 x 600 x 245

600 x 760 x 245

Protection against overvoltages Protections Communications

300 joules Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / DB9 with RS232 and contacts / Slot for communications interface

Input plugs

1 iEC 320 C14

1 iEC 320 C20

Output sockets

8 iEC 320 C13

8 iEC 320 C13 + 1 iEC 320 C19

Standards Operating temperature Relative humidity Colour Noise level at 1 m Standard equipment provided

Safety: EN 62040-1 and Directive 2006/95/EL; EMC: EN 620040-2 category C2 and Directives 2004/108/EL 0 °C / +40 °C < 95% non-condensing Black < 40 dBA Power cable, serial cable, USB cable, safety manual, quick start guide

www.riello-ups.com

53


VFI TYPE

Sentinel Dual

SOHO

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

High Power

1:1 3:1 3,3-10 kVA

6

USB plug

Hot swap battery

Energy share

Highlights

• Simplified installation • Operating mode selection • High quality output voltage • High battery reliability • Emergency function

54

Sentinel Dual is the best solution for powering mission critical applications and electro-medical devices requiring maximum power reliability. Flexibility of installation and use (digital display, user-replaceable battery set), as well as the many communication options available, makes Sentinel Dual suitable for many different applications from IT to security. Sentinel Dual can be installed on the floor or in rack cabinets for networking applications. The Sentinel Dual range is available in 3.3-4-5-6-8-10 kVA models with on-line double conversion technology (VFI): the

load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of voltage, form and frequency. In addition, the input and output filters significantly increase the load’s immunity to mains disturbances and lightning strikes. Technology and performance: selectable Economy Mode and Smart Active Mode functions. Diagnostics: Standard digital display, RS232 and USB interfaces with PowerShield3 software included, communications slot for connectivity accessories.


1. Release the display panel by applying pressure to the catches

2. Rotate the display panel counter clockwise and then secure it back in place

3. ROTATE THE UPS BY 90º

4. ATTACH THE RACK SUPPORTS

90°

90°

Simplified installation • Can be installed on the floor (tower version) or in rack mount cabinets (rack version). The display panel can be rotated (using the key supplied) • Low noise (<40 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan. • External bypass option for maintenance with interruption-free switching (5-6-8-10 kVA SDL) • Operation guaranteed up to 40°C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures) • Two built-in IEC output sockets with thermal protection (5-6-8-10 kVA SDL) • On the 5-6-8-10 kVA models, it is also possible to program two 10 A output sockets when the mains power supply fails (PowerShare function).

Operating mode selection Functions can be programmed via software or manually via the front display panel. • On line • Economy Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply • Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply • Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode). • Frequency converter operation (50 or 60 Hz).

High quality output voltage • Even with non-linear loads (IT loads with a crest factor of up to 3:1) • High short circuit current on bypass • High overload capacity: 150% by inverter (even with mains failure) • Filtered, stabilised and reliable voltage (double conversion on-line technology

(VFI compliant with EN62040-3)), with filters for the suppression of atmospheric disturbances. • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

High battery reliability • Automatic and manual battery test • Reduced ripple component (detrimental to the batteries) using a low ripple current discharge (LCRD) system • Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap) • Unlimited extendible runtime using matching Battery Boxes • The batteries do not cut in during mains failures of <40 ms (high hold up time) or when the input supply is between 84 V to 276 V.

Emergency function This configuration ensures the operation of those emergency systems that require continuous, reliable and long-lasting power supply in the event of a mains power failure, such as emergency lighting, fire detection/ extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive startup (Soft Start) in order to prevent overload.

Battery optimisation The wide input voltage range and a high hold-up time minimise battery usage and increase efficiency and battery life; for smaller power breaks, energy is drawn from a group of appropriately-sized capacitors.

Other features • Selectable output voltage (220-230-240 V) • Auto-restart when mains power is restored (programmable via software) • Bypass on: when the machine is switched off, it automatically goes into bypass and battery charge mode • Minimum load switch-off • Low battery warning • Start-up delay • Total microprocessor control • Automatic bypass without interruption • Use of IMS modules (Insulated Metallic Substrates) • Status, measurements and alarms available on standard backlit display • UPS digital updating (flash upgradeable) • Input protection via resettable thermal switch • Back-feed protection standard: to prevent energy from being fed back to the network • Manual switching to bypass.

Advanced communications • Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, VMWare ESX and other Unix operating systems • Plug and play function • USB port • RS232 serial port • Slot for installation of communications boards.

2-YEAR WARRANTY

EnergyShare (5-10 kVA versions) Two 10 A configurable IEC output sockets allow for runtime optimisation by programming the switching off of low priority loads on mains failure; alternatively, emergency loads that are normally not powered when mains is present can be activated.

www.riello-ups.com

55


BATTERY BOX

BB 17 5

19 ”

BB 0 66

17 5

0 52

DETAILS

SDL 3300 SDL 4000

USB PORT

SDL 5000 SDL 6000

SDL 8000 SDL 10000 SDL 6500 TM SDL 8000 TM SDL 10000 TM

SERIAL PORT COMMUNICATIONS SLOT

INPUT THERMAL PROTECTION

INPUT SOCKET

OUTPUT SOCKETS

BATTERY EXPANSION CONNECTOR INPUT CABLE ACCESS OUTPUT CABLE ACCESS

OPTIONS

56

Software PowerShield3 PowerNetGuard

MULTI I/O Interface kit AS400 MULTIPANEL RTG 100

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 372 MULTICOM 382 MULTICOM 401

Manual Bypass 16 A L Manual bypass 16 A Rack  L Automatic bypass 16 A  L Automatic bypass 16 A Rack  L PRODUCT ACCESSORIES Universal rails for installation in rack cabinets Note: 

L 3300-4000 VA

BB 19 ”

0 52

BC SDL 108-B1

630

BB

455

455

Dimensions (mm)

BB SDL 192-A3/ BB SDL 192-A6

4U

BB SDL 108-A4 / BB SDL 108-M1

4U

MODELS

BB

0 66

21 5

5 65


MODELS POWER

SDL 3300

SDL 4000

SDL 5000

SDL 6000

3300 VA/2300 W

4000 VA/2400 W

5000 VA/3500 W

6000 VA/4200 W

SDL 8000

SDL 10000

8000 VA/7200 W 10000 VA/9000 W

INPUT Nominal voltage

220-230-240 Vac

Minimum voltage

164 Vac @ 100% load / 84 Vac @ 50% load

Nominal frequency

50/60 Hz ±5Hz

Power factor

> 0.98

Current distortion

≤7%

BYPASS Voltage tolerance

180 - 264 Vac (selectable in Economy Mode or Smart Active Mode)

Frequency tolerance

Selected frequency ±5% (selectable by user)

OUTPUT Nominal voltage

220-230-240 Vac selectable

Voltage distortion

< 3% with linear load / < 6% with non-linear load

Frequency

50/60 Hz selectable

Static variation

1,5%

Dynamic variation

≤ 5% in 20 ms

Waveform

Sinusoidal

Crest factor

3:1

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

4-6 hours

OVERLOAD TIMES 100% < Load < 110%

1 minute

110% < Load < 150%

4 seconds

Load > 150%

0.5 seconds

OTHER FEATURES Net weight (kg) Gross weight (kg) Dimensions (WxDxH) (mm) Packaged dimensions (WxDxH) (mm)

38

40

62

64

94

95

42.5

44.5

70

72

102

103

175 x 520 x 455 tower 19” x 520 x 4U rack

175 x 660 x 455 tower 19” x 660 x 4U rack

2 x (175 x 660 x 455) tower 2 x (19” x 660 x 4U) rack

540 x 620 x 280

720 x 530 x (270+15)

780 x 555 x (270+15)

Efficiency Line-interactive/Smart Active Protections

98% Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery

Communications Input plugs Output sockets Standards

USB / RS232 + slot for communications interface 1 iEC 320 C20

Terminal board

2 IEC 320 C13 + 1 iEC 320 C20

Terminal board + 2 IEC 320 C13

EN 62040-1 EMC EN 62040-2 Directives 73/23 - 93/68 - 2004/108 EC EN 62040-3

Operating temperature

0 °C / +40 °C

Relative humidity

< 95% non-condensing

Colour Noise level at 1 m

Dark grey RAL 7016 < 40 dBA

2 10 A cables; 1 IEC-16 A plug; Standard equipment provided software; serial cable; keys for releasing display panel; handles kit

< 45 dBA 2 cable guides; cable tips; software; serial cable; keys for releasing display panel; handles kit

www.riello-ups.com

57


MODELS POWER

SDL 6500 TM

SDL 8000 TM

SDL 10000 TM

6500 VA/5850 W

8000 VA/7200 W

10000 VA/9000 W

INPUT Nominal voltage

400 Vac three-phase + N

Minimum voltage (F + N)

164 Vac @ 100% load / 84 Vac @ 50% load

Nominal frequency

50/60 Hz ±5 Hz

Power factor

> 0.95

BYPASS Voltage tolerance

180 - 264 Vac (selectable in Economy Mode or Smart Active Mode)

Frequency tolerance

Selected frequency ±5% (selectable by user)

OUTPUT Nominal voltage

220-230-240 Vac selectable

Voltage distortion

< 3% with linear load / < 6% with non-linear load

Frequency

50/60 Hz selectable

Static variation

1,5%

Dynamic variation

≤ 5% in 20 ms

Waveform

Sinusoidal

Crest factor

3:1

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

4-6 hours

OVERLOAD TIMES 100% < Load < 110%

1 minute

110% < Load < 150%

4 seconds

Load > 150%

0.5 seconds

OTHER FEATURES Net weight (kg)

91

94

95

Gross weight (kg)

99

102

103

Dimensions (WxDxH) (mm) Packaged dimensions (WxDxH) (mm)

780 x 555 x (270+15)

Smart Active efficiency

up to 98%

Protections Communications Input plugs Output sockets Standards Operating temperature Relative humidity Colour Noise level at 1 m Standard equipment provided

58

2 x (175 x 660 x 455) tower / 2 x (19” x 660 x 4U) rack

Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / RS232 + slot for communications interface Terminal board Terminal board + 2 IEC 320 C13 EN 62040-1 EMC EN 62040-2 Directives 73/23 - 93/68 - 2004/108 EC EN 62040-3 0 °C / +40 °C < 95% non-condensing Dark grey RAL 7016 < 45 dBA 2 cable guides; cable tips; software; serial cable; keys for releasing display panel; handles kit


www.riello-ups.com

59


VFI TYPE

Sentinel Power Green

SOHO

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

1:1 6 kVA 1:1 3:1 8-20 kVA

6

USB plug

Energy share

Service 1st start

Highlights

• Small footprint • Power factor 0.9 • High efficiency 97% • Parallelable 1+1 • Simplified installation • High quality output voltage

60

Sentinel Power Green is the ideal solution for protecting IT systems, telecommunications equipment and mission critical systems such as safety devices, ensuring maximum power reliability. Sentinel Power Green is designed and built using state-of-the-art technology and components to provide maximum protection to the powered loads with no impact on downstream systems and optimised energy savings. The series includes 6 kVA single/singlephase and 8-20 kVA single/single-phase and three/single-phase models with online double conversion technology (VFI):

the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of form and frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology and performance, Sentinel Power Green is one of the best UPS available on the market today: selectable Economy Mode and Smart Active Mode functions; custom diagnostics LCD display, RS232 and USB interfaces with Powershield3 software, ESD input, interface slot with optional boards.


High UPS reliability • Total microprocessor control. • Interruption-free static and manual bypass. • Specifications guaranteed up to 40°C (the components are designed to work at high temperatures and thus are subject to less stress at normal temperatures).

Parallelable Parallel configuration of 2 units for (1+1) redundant or power parallel system. The UPS continue to operate in parallel even if the connection cable is interrupted (Closed Loop).

Operating mode selection The operating mode can be programmed via software or manually via the front display panel. • On line: double conversion Mode: for critical applications. • Economy Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply. • Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply. • Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode). • Frequency converter operation (50 or 60 Hz).

High quality output voltage • Even with non-linear loads (IT loads with a crest factor of up to 3:1). • High short circuit current on bypass. • High overload capacity: 150% by inverter (even with mains failure). • Filtered, stabilised and reliable voltage (double conversion on-line technology - VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances. • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible. • Unlimited extendible runtime using matching Battery Boxes. • The batteries do not cut in during mains failures of <40 ms (high hold up time) or when the input supply is between 84 V to 276 V.

Low impact on the mains Sinusoidal uptake of input current on singlephase/single-phase series.

Other features • Advanced diagnostics: status, measurements and alarms available on custom LCD display. • Low noise (<40 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan (>20 kHz, value above audible range).

• Auto restart (automatic when mains supply is restored, programmable via software or display panel). • Emergency function: the UPS can be selected to function only when the mains power supply fails (emergency lights). • Back-feed protection standard: to prevent energy from being fed back to the network. • UPS digital updating (flash upgradeable).

Advanced communications • Compatible with Riello UPS TeleNetGuard remote monitoring. • Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, VMWare ESX and other Unix operating systems. • RS232 serial and USB ports. • Plug and play function. • Slot for installation of communications boards.

Simplified installation • UPS can be installed on a single-phase or three-phase distribution network. • Output terminal board + 2 IEC sockets for powering local consumers (computers, modems, etc.). • Simplified positioning (built-in castors).

High battery reliability • Automatic and manual battery test. • Proper battery care is critical to ensuring www.riello-ups.com

61


OPTIONS

DETAILS SPM 6 - SPH 8

Software PowerShield3 PowerNetGuard

SPH 10 - SPH 15 - SPH 20

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 372 MULTICOM 382 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 Manual Bypass MBB 100 A

USB PORT

PRODUCT ACCESSORIES Isolation transformer module (hlp) mm/kg: 500 x 400 x 265 / 80 (only for 5000-6000 VA models)

terminal board

RS232 SERIAL PORT COMMUNICATIONS INTERFACE SLOT PARALLEL COMMUNICATIONS PORT BATTERY EXPANSION CONNECTOR IEC SOCKETS INPUT SWITCH (SWIN) MAINTENANCE BYPASS (SWMB)

OUTPUT SWITCH (SWOUT) EMERGENCY SWITCH DEVICE (ESD)

BATTERY BOX BB SPM 180-A3 / BB SPM 180-M1 BB SPH 240-a3 / BB SPh 240 M1

708

Dimensions (mm)

BB MST 1320 480

1320

MODELS

BB

BB 26 2

62

4 65

40 0

5 81


MODELS POWER

SPM 6

SPH 8

SPH 10

SPH 10 ER

SPH 15

SPH 20

SPH 20 ER

6000 VA/ 5400 W

8000 VA/ 6400 W

10000 VA/ 9000 W

10000 VA/ 9000 W

15000 VA/ 13500 W

20000 VA/ 18000 W

20000 VA/ 18000 W

INPUT Nominal voltage

220-230-240 Vac 1 ph

220-230-240 Vac 1 ph / 380-400-415 Vac 3 ph + N

Minimum voltage without battery intervention

176 Vac @ 100% load / 110 Vac @ 50% load

Maximum operating voltage

276 Vac

Nominal frequency

50/60 Hz ±10 Hz

BYPASS Voltage tolerance

160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)

Frequency tolerance

Selected frequency ±10%

OUTPUT Nominal voltage

220-230-240 Vac selectable

Voltage distortion

< 2% with linear load / < 5% with non-linear load

Current distortion

3%

Frequency

50/60 Hz selectable or with automatic selection

Static variation

± 1,5 %

Dynamic variation

≤ 5% in 20 ms

Waveform

Sinusoidal

Crest factor

≥3:1

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

6-8 hours

Recharge current (only for ER versions)

n.a.

8A

n.a.

8A

OVERLOAD TIMES 100% < Load < 110%

5 min

110% < Load < 130%

1 min

130% < Load < 150%

10 sec

Load > 150%

0.1 sec

OTHER FEATURES Net weight (kg)

63

78

84

88

140

157

48

Gross weight (kg)

77

92

92

42

164

175

66

Dimensions (WxDxH) (mm)

262 x 654 x 708

350 x 731 x 818

Packaged dimensions (WxDxH) (mm)

720 x 428 x 970

870 x 475 x 1075

Smart Active efficiency Protections Communications Parallel Input plugs Output sockets Standards Operating temperature Relative humidity Colour Noise level at 1 m Moving the UPS

up to 98% Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / RS232 + slot for communications interface max. 2 units in parallel with optional kit Terminal board Terminal board + 2 IEC 320 C13 EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3 0 °C / +40 °C < 95% non-condensing Dark grey RAL 7016 < 70 dBA castors

www.riello-ups.com

63


VFI TYPE

Sentinel Power

SOHO

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

1:1 5-6 kVA 1:1 3:1 6,5-10 kVA

6

USB plug

Energy share

Supercaps UPS

Service 1st start

Highlights

• High UPS reliability • Operating mode selection • High quality output voltage • Simplified installation • High battery reliability • Low impact on the mains 64

Sentinel Power is the ideal solution for powering sensitive, mission critical systems such as safety devices (electro-medical devices), ensuring maximum power reliability. The series includes 5-6 kVA single/singlephase and 6.5-8-10 kVA single/single-phase and three/single-phase models with on-line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of voltage, form and

frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology, performance (selectable Economy and Smart Active Modes) and diagnostics (LCD custom display, RS232 and USB interfaces with Powershield3 software included, ESD input, interface slot for optional boards), Sentinel Power is one of the best UPS available on the market.


High UPS reliability

Energy-share

• Total microprocessor control. • Interruption-free static and manual bypass. • Specifications guaranteed up to 40 °C (the components are designed to work at high temperatures and thus are subject to less stress at normal temperatures).

Two 10 A configurable IEC output sockets allow for runtime optimisation by programming the switching off of low priority loads on mains failure; alternatively, emergency loads that are normally not powered when mains is present can be activated.

Operating mode selection

Low impact on the mains

The operating mode can be programmed via software or manually via the front display panel. • On line. • Economy Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply. • Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply. • Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode). • Frequency converter operation (50 or 60 Hz).

Sinusoidal uptake of input current on singlephase/single-phase series.

High quality output voltage • Even with non-linear loads (IT loads with a crest factor of up to 3:1). • High short circuit current on bypass. • High overload capacity: 150% by inverter (even with mains failure). • Filtered, stabilised and reliable voltage (double conversion on-line technology - VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances. • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

Other features • Advanced diagnostics: status, measurements and alarms available on custom LCD display • Low noise (<40 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan (>20 kHz, value above audible range) • Auto restart (automatic when mains supply is restored, programmable via software or display panel) • Emergency function: the UPS can be selected to function only when the mains power supply fails (emergency lights) • Back-feed protection standard: to prevent energy from being fed back to the network • UPS digital updating (flash upgradeable).

VMWare ESX and other Unix operating systems • RS232 serial port • Plug and play function • Slot for installation of communications boards.

Advanced communications • Compatible with Riello UPS TeleNetGuard remote monitoring • Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux,

Simplified installation • UPS can be installed on a single-phase or three-phase distribution network • Output terminal board + 2 IEC sockets for powering local consumers (computers, modems, etc.) • Simplified positioning (built-in castors).

High battery reliability • Automatic and manual battery test • Reduced ripple component (detrimental to the batteries) using a low ripple current discharge (LCRD) system • Unlimited extendible runtime using matching Battery Boxes • The batteries do not cut in during mains failures of <40 ms (high hold up time) or when the input supply is between 84 V to 276 V. www.riello-ups.com

65


BATTERY BOX

Dimensions (mm)

BB SPW 240-A3 / BB SPW 240-A6 BC SPW 240-M1/ BC SPW 240-M4

615

MODELS

OPTIONS

BB 5 78 28 2

Software PowerShield3 PowerNetGuard

MULTICOM 382 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 Manual Bypass MBB 100 A

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 372

PRODUCT ACCESSORIES Isolation transformer module (hlp) mm/kg: 500 x 400 x 265 / 80 (only for 5000-6000 VA models)

DETAILS SPW 5000 - SPW 6000 SPW 6500 - SPT 8000 - SPW 10000 ON/OFF SWITCHES

COMMUNICATIONS INTERFACE SLOT EMERGENCY SWITCH DEVICE (ESD)

RS232 SERIAL PORT IEC SOCKETS

INPUT SWITCH (SWIN)

BATTERY FUSE PORT (SWBT)

66

USB PORT

MAINTENANCE BYPASS (SWMB)

OUTPUT SWITCH (SWOUT)


MODELS POWER

SPW 5000

SPW 6000

SPT 6500

SPT 8000

SPT 10000

5000 VA/4000 W

6000 VA/4800 W

6500 VA/5200 W

8000 VA/6400 W

10000 VA/8000 W

INPUT Nominal voltage

220-230-240 Vac single-phase

Minimum voltage without battery intervention

220-230-240 Vac single-phase or 380-400-415 Vac three-phase + N

170 Vac @ 100% load / 140 Vac @ 50% load

Nominal frequency

50/60 Hz ±5 Hz

BYPASS Voltage tolerance

180 - 264 Vac (selectable in Economy Mode or Smart Active Mode)

Frequency tolerance

Selected frequency ±5%

OUTPUT Nominal voltage

220 - 230 - 240 Vac selectable

Voltage distortion

< 3% with linear load / < 6% with non-linear load

Frequency

50/60 Hz selectable or with automatic selection

Static variation

± 1,5 %

Dynamic variation

≤ 5% in 20 ms

Waveform

Sinusoidal

Crest factor

≥3:1

BATTERIES Type

VRLA AGM maintenance-free lead based

Recharge time

6-8 hours

OVERLOAD TIMES 100% < Load < 125%

1 minute

125% < Load < 150%

4 seconds

Load > 150%

0.5 seconds

OTHER FEATURES Net weight (kg)

91

Gross weight (kg)

99

Dimensions (WxDxH) (mm) Packaged dimensions (WxDxH) (mm) Smart Active efficiency Protections Communications Input plugs Output sockets Standards Operating temperature Relative humidity Colour Noise level at 1 m Moving the UPS

92

105

106

100

110

111

282 x 785 x 615 863 x 388 x (650+15) up to 98% Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery USB / RS232 + slot for communications interface Terminal board Terminal board + 2 IEC 320 C13 EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3 0 °C / +40 °C < 95% non-condensing Dark grey RAL 7016 < 45 dBA castors

www.riello-ups.com

67


VFI TYPE

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

Multi Sentry 1:1 3:1 10-20 kVA 3:3 10-120 kVA

6

Supercaps UPS

USB plug

SmartGrid ready

Energy share

Service 1st start

Highlights

• Complete range 10-120 kVA • Small footprint • High efficiency up to 96.5% • Zero impact source • Flexibility of use • Advanced communications 68

The Multi Sentry series is ideal for protecting data centres and telecommunications systems, IT networks and critical systems in general, where the risks connected with poor energy supply can compromise the continuity of activities and services. The Multi Sentry series is available in 10-12-15-20 kVA models with three-phase/ single-phase input and single-phase output, and 10-12-15-20-30-40-60-80-100-120 kVA models with three-phase input and output and on-line double conversion technology in accordance with VFI-SS-111 classification (as set out in standard IEC EN 62040-3).

Multi Sentry is designed and built using state-of-the-art technology and components. It is controlled by a DSP (Digital Signal Processor) microprocessor, to provide maximum protection to the powered loads with no impact on downstream systems, and optimised energy savings. Its highly flexible design allows full compatibility with both three-phase and single-phase power supplies, thus eliminating problems in connecting the UPS to the system.

Zero impact source Multi Sentry solves installation problems in systems where the power supply has limited


High output State-of-the-art three-level NPC inverters are used to achieve an operating efficiency of 96.5%. This technology halves (50%) the energy dissipated in a year by traditional UPS, with an efficiency level of 92%. Its exceptional performance makes it possible to recover the capital investment cost in less than three years of operation.

Battery care system Proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible. Battery recharging: Multi Sentry is suitable for use with hermetically sealed lead-acid (VRLA), AGM and GEL batteries and Open Vent and Nickel Cadmium batteries. Depending on the battery type, different charging methods are available: • One-level voltage recharge, typically used for widely available VRLA AGM batteries • Two-level voltage recharge according to IU specification • Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries. Recharge voltage compensation based on temperature in order to prevent excessive battery charges or overheating. Battery tests to diagnose in advance any reduction in performance or problems with the batteries. Deep discharge protection: during extended low-load discharges, the end-of-discharge voltage is increased - as recommended by battery manufacturers - to prevent damage or reduced battery performance.

MST 40 UPS 40 kVA conventional

Efficiency %

power available, where the UPS is supported by a generator or where there are compatibility problems with loads that generate harmonic currents; Multi Sentry has a zero impact on its power source, whether this is the mains power supply or a generator: • input current distortion < 3% • input power factor 0.99 • power walk-in function that ensures progressive rectifier start up • start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system. In addition, Multi Sentry plays a filtering and power factor correction role in the power network upstream of the UPS, as it eliminates harmonic components and reactive power generated by the power utilities.

100 98 96 94 92 90 88 86 84 82 80 78 76 0 20 30 40

Ripple current: recharge ripple current (residual AC component) is one of the main causes of reduced reliability and battery life. Using a high frequency battery charger, Multi Sentry reduces this value to negligible levels, prolonging battery life and maintaining high performance over a long period of time. Wide voltage range: the rectifier is designed to operate within a wide input voltage range (up to - 40% at half load), reducing the need for battery discharge and thus helping to extend battery life.

Maximum reliability and availability Distributed parallel configuration of up to 6 units per redundant (N+1) or power parallel

60

80

100

120

Load %

system. The UPS continue to operate in parallel even if the connection cable is interrupted (Closed Loop).

Low running costs Advanced technology and use of high performance components, allows Multi Sentry to provide exceptional performance and efficiency, with a compact size: • the smallest overall footprint is only 0.26 sqm for Multi Sentry 20 kVA with batteries • the type of input stage (IGBT rectifier) ensures an input power factor close to 1 with low current distortion, avoiding the need for bulky and expensive filters • output power factor of 0.9 providing up to 15% more active power than a traditional UPS, guaranteeing a greater margin when

www.riello-ups.com

69


sizing UPS for potential future load increases.

Flexibility With its flexible configuration, performance, accessories and options, Multi Sentry is suitable for use in a wide range of applications: • suitable for powering capacitive loads, such as blade servers, without any reduction in active power from 0.9 lead to 0.9 lag • On-line, Eco, Smart Active and Stand By Off operating modes - compatible with centralised power systems (CSS) applications. • frequency converter mode • configurable EnergyShare sockets to preserve (% PA UPS) P Q

CAPACITIVE

100 80

cosfi 0.9

60

e.g.: 10 kVA UPS supplies 9 kW load

40

cosfi 1

20

e.g.: 10 kVA UPS supplies 9 kW load

% PA 0 25

50

75

100

(% P UPS) P

20 40 60

cosfi 0.9

e.g.: 10 kVA UPS supplies 9 kW load

neutral earthing (separate power sources), or for galvanic isolation between the input and output • 220 V three-phase IN/OUT version and 50/60 Hz frequency for 10-40 kVA power ratings • different sized battery cabinets and capacities, for extended runtimes • with the MST 60-100 the UPS can be raised up to 25 cm from the ground to allow the cables to pass more freely to/ from the UPS terminal board.

Advanced communications Multi Sentry is equipped with a back-lit graphic display (240x128 pixels) providing UPS information, measurements, operating states and alarms in different languages. It can also display wave forms and voltage/ current forms. Multi Sentry Compact (MCM/MCT)

network adapters, potential free contacts, etc. • REPO Remote Emergency Power Off for switching off the UPS via a remote emergency button • Input for the connection of the auxiliary contact of an external manual bypass • Input for synchronisation from an external source • Graphic display panel for remote connection.

80

INDUCTIVE 100

(% PA UPS) P Q

runtime for the most critical loads or to be activated only when mains power fails • Cold Start to switch on the UPS even when there is no mains power present • MST/MSM version: cabinet (1320 x 440 x 850mm HxWxD) for optimised solutions when medium to long-term runtimes are required. • optional temperature sensor for external battery cabinets, to assist recharge voltage compensation • high power battery chargers to optimise charge time in the event of long runtimes • optional dual input mains power supply • isolation transformers for modifying the MST 60-100 with Socle box (h: 1850 mm) 70

The default screen displays UPS status, graphically indicating the status of the various assemblies (rectifier, batteries, inverter, bypass). • Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software included for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, VMWare ESX and other Unix operating systems • Compatible with TeleNetGuard remote monitoring service • RS232 serial and USB ports • 3 slots for the installation of optional communications accessories such as


BATTERY BOX BB 1600 480-S5 / AB 1600 480-S5

BB 1900 480-V6 / BB 1900 480-V7 BB 1900 480-V8 / BB 1900 480-V9 AB 1900 480-V9

up to 60 kVA

up to 80 kVA

up to 120 kVA

Dimensions (mm) 1320

BB

40 0

BB

5 81

65 0

0 75

BB

1900

UPS models

BB 1320 480-T4 / BB 1320 480-T5 BB 1320 480-T2 / AB 1320 480-T5

1600

MODELS

86 0

0 80

DETAILS MST 120 (front) PARALLEL CONNECTORS Connectors repo - AS400 USB - RS232 COMMUNICATIONS INTERFACE SLOT ENERGYSHARE SOCKET

MST / MSM 10 รท 20 (back)

MST 60 - 80 - 100 (front) COMMUNICATIONS INTERFACE SLOT

MSM 10 - 20 MST 10 - 40 (front)

SLOT FOR MULTICOM 382/392 BOARD

ENERGYSHARE SOCKETS

Connectors repo - AS400 USB - RS232 PARALLEL SLOTS

MST 30 รท 40 (back) Connectors repo - AS400 USB - RS232

SLOT FOR MULTICOM 382/392 BOARD

SWBATT ENERGYSHARE SOCKETS

SWBYP SWMB

SWOUT

SWMB SWOUT

MST 60 รท 100 (back)

SWBYP

SLOT FOR MULTICOM 382/392 BOARD

SWMB SWIN SWBYP SLOT FOR MULTICOM 382/392 AUXILIARY BOARD

ENERGYSHARE SOCKETS

SWIN

OPTIONS Software PowerShield3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351

MULTICOM 352 MULTICOM 372 MULTICOM 382 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 56K Modem GSM Modem MBB 100 A

PRODUCT ACCESSORIES Battery temperature sensor Powerful battery charger Programmable relay board MULTICOM 392 UPS with internal isolation transformers (10-40 kVA) UPS 220 V in/out IP rating IP31/IP42 Socle Box for MST 60-100 Energyshare sockets

www.riello-ups.com

71


MODELS

MCM/MSM 10 BAT

MCM/MSM 12 BAT

MCM/MSM 15 BAT

MCM/MSM 20 BAT

INPUT Nominal voltage

380-400-415 Vac three-phase + N / 220-230-240 Vac single-phase + N

Nominal frequency

50/60 Hz

Frequency tolerance

40 - 72 Hz

Power factor at full load

0.99

Current distortion

thdi ≤ 3%

BYPASS Nominal voltage

220-230-240 Vac single-phase + N

Number of phases

1

Voltage tolerance

180 - 264 V (selectable)

Nominal frequency

50 or 60 Hz (selectable)

Frequency tolerance

±5 (selectable)

OUTPUT Nominal power (kVA) Active power (kW)

10

12

15

20

9

10.8

13.5

18

Power factor

0.9

Number of phases

1

Nominal voltage (V)

220-230-240 Vac single-phase + N (selectable)

Static variation

± 1%

Dynamic variation

± 3%

Crest factor

3 : 1 Ipeak/Irms

Voltage distortion

≤ 1% with linear load / ≤ 3% with non-linear load

Frequency

50/60 Hz

Frequency stability during battery operation Overload at Pf 0.8

0.01% 115% unlimited, 125% for 10 minutes, 150% for 1 minute, 168% for 5 seconds

BATTERIES Type

VRLA AGM/GEL/NiCd/Li-ion/Supercaps

Recharge time

6 hours

INFO FOR INSTALLATION Weight without batteries (kg) (MCM/MSM) Dimensions (WxDxH) (mm) Communications Operating temperature Relative humidity Colour Noise level at 1 m IP rating Smart Active efficiency

Standards

Moving the UPS BAT

72

Also available with internal batteries

80/105

82/110

90/115

95/120

320 x 840 x 930 (MCM version) / 440 x 850 x 1320 (MSM version) 3 slots for communications interface / USB / RS232 0 °C / +40 °C 90% non-condensing Dark grey RAL 7016 < 52 dBA IP20 up to 98% European Directives: L V 2006/95/CE low voltage Directive EMC 2004/108/CE electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111 castors


MODELS

MCT/MST MCT/MST MCT/MST MCT/MST MST 30 BAT MST 40 BAT MST 60 12 BAT 15 BAT 20 BAT 10 BAT

MST 80 MST 100 MST 120

INPUT Nominal voltage

380-400-415 Vac three-phase + N

Nominal frequency

50/60 Hz

Frequency tolerance

40 - 72 Hz

Power factor at full load

0.99

Current distortion

thdi ≤ 3%

BYPASS Nominal voltage

380-400-415 Vac three-phase + N

Number of phases

3+N

Voltage tolerance

180 - 264 V (selectable)

Nominal frequency

50 or 60 Hz (selectable)

Frequency tolerance

±5 (selectable)

OUTPUT Nominal power (kVA) Active power (kW)

10

12

15

20

30

40

60

80

100

120

9

10.8

13.5

18

27

36

54

72

90

108

Power factor

0.9

Number of phases

3+N

Nominal voltage

380-400-415 Vac three-phase + N (selectable)

Static variation

± 1%

Dynamic variation

± 3%

Crest factor

3 : 1 Ipeak/Irms

Voltage distortion

≤ 1% with linear load / ≤ 3% with non-linear load

Frequency

50/60 Hz

Frequency stability during battery operation

0.01%

Overload at Pf 0.8

115% unlimited, 125% for 10 minutes, 150% for 1 minute, 168% for 5 seconds

BATTERIES Type

VRLA AGM/GEL/NiCd/Li-ion/Supercaps

Recharge time

6 hours

INFO FOR INSTALLATION Weight without batteries (kg) (MCT/MST)

80/105

Dimensions (WxDxH) (mm)

82/110

90/115

320 x 840 x 930 (MCT version) 440 x 850 x 1320 (MST version)

Communications

Standards

Moving the UPS BAT

440 x 850 x 1320

190

200

220

380 750 x 855 x 1900

500 x 850 x 1600

90% non-condensing

Colour

Smart Active efficiency

145

0 °C / +40 °C

Relative humidity

IP rating

135

3 slots for communications interface / USB / RS232

Operating temperature

Noise level at 1 m

95/120

Dark grey RAL 7016 < 52 dBA

< 48 dBA

< 56 dBA

< 58 dBA

< 70 dBA

IP20 up to 99% European Directives: L V 2006/95/CE low voltage Directive EMC 2004/108/CE electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111 castors (10 - 100 kVA) / transpallet (120 kVA)

Also available with internal batteries

www.riello-ups.com

73


VFI TYPE

DATACENTER

ONLINE

E-MEDICAL

Multi Guard 3:3 1-8 x 15 kVA

5 Service 1st start

Highlights

• Power flexibility 15-120 kVA • UPS module with hot-swap function • Modular power and runtime • Intelligent battery charging system • High MTBF and low MTTR 74

The Multi Guard modular UPS is a scalable three-phase / three-phase uninterruptible power supply system with double conversion technology. Its power capacity ranges from 15kVA to 120kVA, delivering the best combination of reliability, functionality and flexibility. The Multi Guard N+X parallel architecture adopts a highly intelligent modular design to achieve maximum power availability and redundancy. It is specially designed to meet the protection demands of mission critical

loads in data centres or other important applications. Each module has an individual power capacity of 15 kVA, and a standard cabinet can be fitted with up to 8 modules to reach 120 kVA. If the load is within permitted limits, modules can be hot-swapped to enable true power continuity without any interruptions.

System features • Maximum 120kVA capacity in a 19“ rack. • Input power factor >0.99


THDi <2% and output voltage distortion equal to 1.5%. • 15 kVA per module with hot-swap function. • The LCD display on the front panel displays unit status and important information such as input and output nominal values, capacity, temperature and autonomy. • Communication port for standard Ethernet and relay contact board. • DSP technology, IGBT input. • 36 Ampere battery charge current on a 120 kVA system.

Further advantages • The Multi Guard UPS power modules use the latest DSP microchip technology. This reduces hardware components, increases UPS reliability and also makes it easier to update and maintain the software. • The UPS operates with load sharing technology. Should any of the UPS modules fail, the load will be taken over by the rest of the modules without interruption. This increases the real time operation and power availability compared to other standby UPS. • The Multi Guard UPS is designed to connect to external battery banks in order to ensure the required battery run time.

Advanced Modular Design The Multi Guard system contains UPS modules, a LCD Display module, the PDU and other accessories. Each UPS module is a fully independent 15kVA UPS. Thanks to the advanced wireless parallel control technology and smart communication, the UPS modules and LCD display modules can be easily replaced at any time without affecting UPS operation. The user friendly “plug & play” design simplifies UPS servicing and maintenance. The Multi Guard de-centralises the control units in each UPS Module. The LCD Display module is for display and communication purposes only. If the LCD Display module fails, the UPS system still functions and supports the load without any interruption.

• Minimise downtime; • Reduce the number of stored spare parts; • Avoid the need for specialised technicians

Intelligent recharging system The Multi Guard UPS system applies a twostep intelligent charging system. The first stage is a constant charging current that can recharge the battery capacity to 90% very quickly. The system then transfers to a constant voltage mode to guarantee the battery can stay fully charged all the time. This intelligent charging system not only reduces the battery recharging time but also extends battery life, saving on battery replacement costs.

Modular Autonomy The Multi Guard 30 and 60 versions are designed to build up internal run time using a single battery module for all power and autonomy requirements. The same battery module is also used to build up the required autonomy in an external cabinet.

Low total Cost of Ownership (TCO): − Lower system set-up costs − Lower energy costs − Lower cooling costs − Lower expansion costs − Lower maintenance costs.

GMT 60 kVA

UPS power selection The Multi Guard can be configured from 1 up to 8 modules in its cabinet to form the most suitable N + X configuration for the application. Multi Guard grows as your needs grow by simply adding further UPS modules and

battery modules to the existing frame. The initial investment is recuperated in cost savings. New power supply requirements can be satisfied without complex and costly replacement operations.

Redundancy Easy maintenance

High capacity MTBF System MTBF for two modules in parallel is more than 1,000,000 hours and power availability is above 99.999%. Each 15-120 kVA redundant configuration guarantees correct operation even in the event of the failure of one of the UPS modules. The module replacement procedure only takes 5 minutes for full system recovery. This solution allows you to:

Scalability www.riello-ups.com

75


OPTIONS PRODUCT ACCESSORIES Modular battery cabinet (9 shelves, 36 battery modules) Relay alarm board Battery cabinets for any autonomy requirements

MULTI GUARD 30 Multi Guard 30 is the entry level to the range. It is the ideal solution for supplying medium-power loads that require one level of redundancy. The solution is very compact and allows the possibility to expand autonomy up to one and a half hours for a 15 kVA model in a N+1 configuration. The power rating ranges from 15 kVA to 30 kVA with 1 or 2 UPS modules in a 19’’ rack cabinet, which is able to house up to 4 battery shelves.

No. OF POWER MODULES

kVA

Typical autonomy (min)(*)

1

15

90

2

30

42

(*) The autonomy refers to the max. number of installed batteries inside the UPS

OPTIONAL

MULTI GUARD 60 The Multi Guard 60 system allows you to install from one to four UPS modules (15 kVA to 60 kVA) in a 19” rack cabinet, which is able to house up to 5 battery shelves. If redundancy is required (N+1 modules) the max. output power will be 45 kVA.

No. OF POWER MODULES

kVA

Typical autonomy (min)(*)

1

15

113

2

30

54

3

45

30

4

60

21

(*) The autonomy refers to the max. number of installed batteries inside the UPS

OPTIONAL

MULTI GUARD 120 The Multi Guard 120 system allows you to install from one to eight UPS modules (15 kVA to 120 kVA) in a 19” rack cabinet, with batteries housed in an external cabinet. This cabinet houses the same battery modules as those used for the GMT 30/60 versions, up to a maximum of 9 battery shelves.

No. OF POWER MODULES

kVA

Typical autonomy (min)(*)

1

15

217

2

30

103

3

45

65

4

60

49

5

75

36

6

90

30

7

105

22

8

120

10

(*) The autonomy refers to the max. number of installed batteries inside the modular battery cabinet (9 shelves).

76


MODEL

GMT - from 15 kVA to 120 kVA

INPUT Voltage

380-400-415 Vac, three-phase + N

Voltage tolerance

from 294 Vac to 520 Vac

Frequency tolerance

between 40 Hz and 70 Hz

Power factor

>0.99

thdi

< 2%

BYPASS Voltage Voltage tolerance Transfer time from on-line to off-line or vice versa

380-400-415 Vac, three-phase + N from 323 Vac to 437 Vac 0 sec

OUTPUT Voltage Voltage stability Frequency

380-400-415 Vac, three-phase + N (selectable) ≤ 1.5% 50 Hz / 60 Hz

UPS MODULE Power Output power

15 kVA / 13.5 kW 15 kVA x number of modules, up to a maximum of 8

SPECIFICATIONS Noise level at 1 m Operating temperature Humidity Storage temperature

from ≤ 60 dBA to ≤ 62 dBA O °C / +40 °C 20% - 90% non-condensing -15 °C +55 °C

UPS module weight (kg)

35

UPS module dimensions (WxDxH) (mm)

440 x 700 x 131

GMT 30 cabinet dimensions (WxDxH) (mm)

600 x 1000 x 1500

GMT 60 cabinet dimensions (WxDxH) (mm)

600 x 1000 x 2000

GMT 120 cabinet dimensions (WxDxH) (mm)

600 x 1000 x 2000

Modular battery cabinet dimensions (WxDxH) (mm) Eco Mode efficiency Standards Moving the UPS

9 battery shelves, 36 battery modules 597x1003x2000 up to 99% Safety: IEC 62040-1 EMC: IEC 62040-2 transpallet

www.riello-ups.com

77


VFI TYPE

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

ONLINE

Multi Guard Industrial 1-3:1 1-8 x 20 kVA 1-3:3 1-8 x 20 kVA

6

USB plug

SmartGrid ready

Service 1st start

Highlights

• High adaptability to input voltage • Zero impact source • Compatible with industrial environments • Modular Plug & Play solution • Complete flexibility 78

The Multi Guard Industrial range was specially developed to ensure power continuity in all sectors deemed critical due to the specific environmental conditions or industrial processes requiring protection. Multi Guard Industrial is available in a 20 kVA stand alone version and in modular versions from 20 to 160 kVA. The two versions are available in both single-phase and three-phase output configurations. This high level of flexibility allows Multi Guard Industrial to accept both single-phase and three-phase inputs with no need for special set ups or operator intervention, ensuring full compatibility with any power supply network.

High adaptability to input voltage Multi Guard Industrial is available in two versions: single-phase and three-phase output, whilst the input stage accepts both a triplet of three-phase supplies out-ofphase by 120° (three-phase 400 V+N) or a triplet of power supplies in phase (singlephase 230 V+N). Thanks to its power supply recognition function the UPS is able to adapt to the input power supply with no need for additional configuration, ensuring the same performance under both applied voltage conditions.

Zero impact source Thanks to the technology it employs,


Parallel configuration and programmable relay contacts board

Multi Guard Industrial solves all problems connected with insertion into power supply grids with limited power, where the UPS is supplied by a generator and where the same network includes single-phase (e.g. railway voltage) and three-phase (e.g. emergency power supply from a generator) supplies. Multi Guard Industrial has zero impact on the power supply source, whether it is a mains grid or generator set, single-phase or three-phase: • power supply voltage recognition (single/ three-phase), with no need for setting up or reconfiguring parameters • input current distortion < 3% • input power factor 0.99 • power walk-in function that ensures progressive rectifier start up • start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system. • ‘cold start’ function for starting the UPS from the battery. In addition, Multi Guard Industrial plays a filtering and power factor correction role in the power network upstream of the UPS as it eliminates harmonic components and reactive power generated by utility suppliers.

Compatible with industrial environments The mechanical structure of Multi Guard Industrial makes it particularly versatile for use in many different sectors. The basic building blocks are 20 kVA UPS. The cabinet is able to house up to four 20 kVA modules and up to two cabinets can be connected in parallel for a total of eight UPS modules and 160 kVA of power. The module connection clamps are laid

Harting connectors

out so that the communication signal connections are segregated and separated from the power connections (input, output, bypass line, battery), thus ensuring complete immunity from interference generated by the power supply grid, which is typically disturbed in industrial environments. Both versions (single-phase and threephase output) are provided with a bypass line separated from the power supply line. This ensures greater availability in that the customer may have a preferential line for the bypass that is not restricted by the potential interference or interruptions that the UPS power supply line may be subject to. The UPS module has a front to back air flow, allowing the UPS to be installed in any environment and preventing the types of ingress problems associated with topvented circulations cabinets. Every UPS module in the Multi Guard Industrial range can be equipped with a parallel board, a relay board with eight programmable outputs and three inputs (one of which is programmable), and two slots for housing communications interface boards from the MultiCOM range, making the UPS compatible with the various types of protocols and supervision systems typical of the industrial environment. The cabinet is designed to house up to four UPS modules. I t has an area that contains all the protection devices and disconnectors for the individual modules (4 input disconnectors, 4 battery disconnectors, 4 bypass line disconnectors and 4 output disconnectors), as well as a manual bypass for isolating the four modules and guaranteeing power continuity in the event of the complete failure of all the UPS units or in the event of scheduled system overhaul.

The cabinet is also equipped with an area that can be used for the insertion of a whole range of accessories for monitoring power that the user can request (surge arresters, energy meters, earth discharge detectors, output distribution, release coils, etc), making the solution compact and optimised for any field of use.

Modular Plug & Play solution Multi Guard Industrial can be purchased as a single 20 kVA UPS module and installed in any cabinet or mechanical support provided by the user. The power terminals (input, output, battery) are connected by Harting connectors, ensuring simplicity and operating safety during insertion/removal, protection against electrical contacts and immunity from environmental conditions typical of industrial environments (dust, humidity, suspended chemical particles). The removal and replacement of a faulty module or the addition into the system of a further UPS module to increase available power or redundancy can be carried out easily by the operator responsible for the system.

Complete flexibility Multi Guard Industrial is the ideal solution for industrial environments in which the UPS must adapt to the various requirements typical of this application. Aside from the distinction between single-phase and threephase output voltages, the UPS module can be used as a stand-alone unit or in a parallel configuration; by simply adding the parallel configuration board in the slot on the front of the module, the UPS can grow as requirements demand (from 20 to 160 kVA). Multiguard Industrial ensures horizontal www.riello-ups.com

79


scalability that minimises the system footprint, the user can thus have power capabilities from 20 to 80 kVA without increasing the footprint. This is particularly advantageous when the system is installed in environments with space limitations (e.g. containers, historic buildings, sites spread out over a territory). Each UPS is equipped with a graphic display, a programmable relay board slot and two slots for communications interfaces, all situated at the front for quick and organised installation. Every UPS module in the Multi Guard Industrial range is completely independent with regards to the control and management of the operator interfaces; this facilitates all monitoring, control and fault-detection operations, ensuring increased reliability in that any malfunctions in parts or accessory will not propagate through the entire system. Multi Guard Industrial is a UPS that uses many components also used in the Multi Sentry range; in particular the display and navigation menus are the

Detail of protective devices and disconnectors

same: this allows for rapid and intuitive access to information as well as simplified management of the spare parts in storage.

Stand-alone version: Different from the cabinet version, the stand alone system is supplied with input, bypass line, output and battery connectors with loose cables three metres in length and filter

OPTIONS Software PowerShield3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 382

boards that the installation technician must position inside the destination cabinet or near the module.

DETAILS MULTICOM 401 MULTI I/O MULTIPANEL RTG 100

Right front panel (UPS MODULE) RS232 PORT USB PORT SLOT FOR MULTICOM 382/392 BOARD

PRODUCT ACCESSORIES Battery temperature sensor Powerful battery charger Programmable relay board Multicom 392 IP rating IP31/IP42 Internal batteries MST range battery cabinets

AS400 PORT R.E.P.O BATTERY TEMPERATURE SENSOR COMMUNICATIONS BOARD SLOT SLOT FOR PARALLEL BOARD cold start switch

Left front panel (UPS MODULE)

OUT

BYPASS

BATTERIES

INPUT

80


MODEL

GMI single-phase output (GMI M) from 20 kVA to 160 kVA

GMI three-phase output (GMI T) from 20 kVA to 160 kVA

INPUT Voltage

380-400-415 Vac, three-phase + N and 220-230-240 Vac single-phase + N (input voltage recognition function)

Voltage tolerance Frequency tolerance

-40/+20% * between 40 Hz and 72 Hz

Power factor

>0.99

thdi

< 3%

BYPASS Voltage Voltage tolerance

220-230-240 Vac, single-phase + N

380-400-415 Vac, three-phase + N

180 - 264 V (selectable) referring to neutral phase

OUTPUT Voltage Voltage stability Frequency

220-230-240 Vac, single-phase + N (selectable)

380-400-415 Vac, three-phase + N (selectable) ≤ 1%

50 Hz / 60 Hz

UPS MODULE Power Output power

20 kVA / 18 kW 20 kVA x number of modules, up to a maximum of 8 (max. 160 kVA)

BATTERIES Layout Type Recharge time

independent batteries for each UPS module or shared by the UPS system VRLA AGM/GEL 6 hours

SPECIFICATIONS Noise level at 1 m Operating temperature Humidity Storage temperature

from ≤ 52 dBA to ≤ 70 dBA O °C / +40 °C 20% - 90% non-condensing -15° +55°

UPS module weight (kg)

64

UPS module dimensions (WxDxH) (mm)

620 x 745 x 320

GMI cabinet weight 80 (kg)

200 (UPS modules excluded)

GMT 80 cabinet dimensions (WxDxH) (mm)

850 x 850 x 2060

Modular battery cabinet dimensions (WxDxH) (mm) Eco Mode efficiency Standards Moving the UPS

9 battery shelves, 36 battery modules 597 x 1003 x 2000 up to 99% Safety: IEC 62040-1 EMC: IEC 62040-2 transpallet (UPS cabinet) - 2 operators (UPS module)

* conditions applied NOTE : The GMI UPS is also compatible with the battery cabinets in the Multi Sentry range (MST)

www.riello-ups.com

81


VFI TYPE

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

Master MPS 3:1 10-100 kVA 3:3 10-800 kVA

4

Supercaps UPS

SmartGrid ready

Flywheel compatible

Service 1st start

Highlights

• Efficiency Control System (ECS) • Robust and reliable • Galvanic isolation • High overload capacity • Extensive parallel configurations 82

Total protection Master MPS series UPS provide maximum protection and power quality for mission critical loads, including data centres, industrial processes, telecommunications, security and electro-medical systems. Master MPS is an on-line double conversion UPS (VFI SS 111 - IEC EN 62040-3) with a transformer isolated inverter. The Master MPS range includes three-phase input and single-phase output versions from 10 to 100 kVA, and three-phase input and

output versions from 10 to 800 kVA. All versions are provided with a 6-pulse thyristor-based rectifier, with or without optional harmonic filters. A 12-pulse thyristor-based rectifier is available on request for the 60 and 80 kVA versions (provided as standard for MPT 800), with or without optional harmonic filters.

Easy source Master MPS makes supplying the UPS from generator sets and MT/BT transformers


simpler and more efficient, reducing power loss in the system and coils, correcting the power factor and eliminating current harmonics created by the loads supplied by the UPS. In addition to this, the progressive rectifier start-up (power walk-in) and the option to reduce battery charging currents, allow for a reduction in the input current uptake. This means less demand on the source, which is particularly useful when the source is a generator set.

Power continuity For years, Riello UPS has developed and supplied solutions for dealing with the different requirements and the problems that inevitably arise in critical applications. Riello UPS offers flexible, high-availability, solutions that are able to adapt to different system structures and critical levels. Riello UPS creates UPS systems that can tolerate a number of component or subsystem failures, while continuing to operate normally, providing power without interruption. This is achieved by careful design, installing redundant elements, eliminating common failure points, scheduling maintenance activities and controlling and supervising the system operating parameters and environment. The TEC service team is ready to provide guidance and advice on projects.

Flexibility Master MPS is suitable for a wide range of applications including IT and the most demanding industrial environments and processes. With several operational configurations including On-Line, Eco, Smart Active, Stand By, Frequency Converter and Voltage Stabiliser. A broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the Riello UPS Group Synchroniser (UGS) and Parallel Systems Joiner (PSJ), sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability.

Battery care system: maximum battery care Normally the batteries are kept charged by the rectifier; when mains power fails, the UPS uses this energy source to power the consumers. Proper battery care is therefore critical to ensuring correct UPS operation under emergency conditions. The Riello UPS battery care system consists of a series of

Detail of connection area

functions designed to optimise battery management and achieve the best performance and operating life possible: • Dual level charging regime to optimise recharge currents and reduce charge times • Temperature compensation and deep discharge protection to reduce battery ageing and improve battery life • Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries • Battery tests to diagnose, in advance, any reduction in performance or problems with the batteries. Master MPS is also compatible with different battery technologies: vented open lead acid, VRLA AGM, Gel, NiCd, Flywheels, Supercaps and Lithium.

• Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software included, with SNMP agent, for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, Novell and other Unix operating systems • The UPS is provided with a cable for direct connection to a PC (Plug and Play) • Double RS232 serial port • Communications slot for network adapter installation; ESD contact (Emergency Switching Device) for switching off the UPS by remote emergency button • Remote display panel with graphic display.

Easy installation

• Distributed or centralised parallel configuration of up to 8 units per redundant (N+1) or power parallel system. Parallel configurations using models with different power ratings are also possible. • Hot System Expansion (HSE): allows the addition of a further UPS into an existing system, without the need to switch off the existing UPS or transfer them to bypass mode. This guarantees maximum load protection, even during maintenance and system expansion. • Maximum levels of availability, even in the event of an interruption to the parallel bus cable: the system is “FAULT TOLERANT”. It is not affected by connection cable faults and continues powering the load without disruption, signalling an alarm condition. • Efficiency Control System (ECS): a system to optimise the operating efficiency of parallel systems, according to the power required by the load. N +1 redundancy is

Master MPS requires a very small space for installation (only 0.64 m2 for a 200kVA system); in addition, front access allows for the servicing of all major components from the front panel, making side access unnecessary. In addition, front access allows servicing of all major components from the front panel, making side access unnecessary. Master MPS requires minimal space for access, utilising top-cabinet ventilation and front panel access.

Specific solutions The UPS can be adapted to meet the most specific requirements. Contact our TEC team to discuss specific solutions and options not listed in this catalogue.

Advanced communications • Compatible with TeleNetGuard for remote monitoring.

Maximum reliability and availability

www.riello-ups.com

83


guaranteed, with every UPS working in parallel at the best load level possible to achieve higher overall efficiency.

that is independent and of a different power rating. • Parallel Systems Joiner (PSJ) Allows two groups of UPS to be connected in parallel whilst operating, in the event of maintenance (with no interruption to the output), using a power coupling switch. Should one of the UPS in one of the parallel groups fail, it is automatically excluded. The PSJ connects the remaining UPS, to

Options • UPS Group Synchroniser (UGS) Allows two or more non-parallel UPS devices to remain synchronised even during mains power failure. The UGS also enables a Riello UPS to be synchronised with another power source

the other parallel group via an external bypass, in order to continue to guarantee load redundancy.

Parallel configuration of up to 8 UPS units with distributed bypass

Parallel configuration of up to 8 UPS units with common bypass

Parallel architecture to ensure redundancy of the power source. + Flexibility and modularity and no single point of failure.

Parallel architecture to ensure redundancy of the power source, with autonomous bypass management. + Selectivity of downstream faults in bypass mode

Bypass mains Mains UPS2

Battery

Battery

UPS1

Mains UPS3...

UPS8

Common BY PASS

Battery

Mains

UPS3... UPS8

Battery

UPS2

Battery

UPS1

Mains

Battery

Mains

Mains

Bypass mains

Maintenance Bypass Cabinet

Load

Load

DYNAMIC DUAL BUS configuration

DUAL BUS SYSTEM configuration

Solution to ensure redundancy up to the distribution of the power supply to the loads and improved STS operation. + Downstream fault discrimination

Solution to ensure redundancy of the power supply even during maintenance. + High availability and redundancy

Mains

Mains

System B Mains

UPS1A

UPS2B

Battery

UPS1B

Bypass 1

Mains

UPS2A

UGS

Bypass 2 Mains

UPS1B

Sinchroniser

PSJ

Static Transfer SWITCH

SWITCH

UPS2B

Battery

UPS2A

System A

Battery

Mains

Battery

UPS1A

Bypass 2

Battery

Mains

Mains

Battery

System B

Battery

Bypass 1

Battery

System A

Load 3 Load 1

Static Transfer SWITCH

Load 4

84

Load 2

Load 1

Load 2


DIMENSIONS

555

0 74

0 74

825

0 74

800

0 80

MPM 100HC MPT 100HC÷200HC

1070

0 74

1900

MPT 800D

1900

1900 1400

MPM/MPT 60HC÷80HC MPT 60D÷80D MPT 60DHC÷80DHC

1900

1400 800

MPM 100 MPT 100÷200

MPM/MPT 10HC÷40HC

1400

MPM/MPT 60÷80

1400

MPM/MPT 10÷40

1070

0 80

00 10

4400

HC= Version with filtering of 5th or 11th harmonics D= Twelve-phase version

OPTIONS Software PowerShield3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352

MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 56K Modem GSM Modem MBB 100 A

Isolation transformer Synchronisation device (UGS) Hot connection device (PSJ) Generator interface Parallel configuration kit (Closed Loop) Battery cabinets empty or for extended runtimes Top Cable Entry cabinets IP rating IP31/IP42

PRODUCT ACCESSORIES Twelve-phase version (D) Filtering of 5th and 11th harmonics (HC)

DETAILS MPS (detail of front) RS232-REPO Connectors Dry CONTACTS COMMUNICATIONS INTERFACE SLOT

SWIN SWBYP FAN FUSES SWMB SWOUT

PARALLEL INTERFACE

UGS INTERFACE

MULTI I/O MODEM INTERFACE

REMOTE ALARM

MPT 200 open

www.riello-ups.com

85


BATTERY BOX BB 1400 384-B2 / BB 1400 384-B3 BB 1900 396-L6 / BB 1900 396-L7 BB 1900 480-V6 / BB 1900 480-V7 BB 1400 384-B4 BB 1900 396-L8 / BB 1900 396-L9 BB 1900 480-V8 / BB 1900 480-V9

MPT 10-60

BB

BB

86 0

0 74

CABINETS WITH TOP ACCESS FOR CABLES

TC E

27 0

0 80

0 80

TC E

40 0

0 0 74 74

64 64 0 0

0 85

TBX 100 M MPM 100

TC E

40 0

00 10

1900

Dimensions (mm)

TBX 10 M - TBX 80 M MPM 10-80

1900

MODELS UPS MODELS

1900

TCE MPT 100-200 MPT 100-200 / MPM 100

1400

Dimensions (mm)

86 0

0 74

SINGLE-PHASE ISOLATION TRANSFORMERS

1900

MODELS UPS MODELS

MPT 800

BB

1400

55 5

MPT 100-200 / MPM 100

1900

Dimensions (mm)

MPT 10-80

1400

UPS MODELS

1900

BB 1400 384-B1

1400

MODELS

0 0 80 80

64 64 0 0

THREE-PHASE ISOLATION TRANSFORMERS

1400

Dimensions (mm)

64 0

86

TBX 100 T - TBX 160 T MPT 100-160

0 74

TBX 200 T - TBX 250 T MPT 200

64 0

0 80

1900

TBX 10 T - TBX 80 T MPT 10-80

1900

MODELS UPS MODELS

80 0

0 80


MODELS

MPM 10 BAT MPM 15 BAT MPM 20 BAT

MPM 30

MPM 40

MPM 60

MPM 80

MPM 100

INPUT Nominal voltage

380 - 400 - 415 Vac three-phase

Voltage tolerance

400 V + 20% /- 25%

Frequency

45 - 65 Hz

Soft start

0 - 100% in 120’’ (selectable)

Permitted frequency tolerance

± 2% (selectable from ± 1% to ± 5% from front panel)

Standard equipment provided

Back Feed protection; separable bypass line

BYPASS Nominal voltage

360-400-420 Vac three-phase + N

Nominal frequency

50 or 60 Hz (selectable)

OUTPUT Nominal power (kVA) Active power (kW)

10

15

20

30

40

60

80

100

9

13,5

18

27

36

54

72

90

Number of phases

1

Nominal voltage

220 - 230 - 240 Vac single-phase + N (selectable)

Static stability

± 1%

Dynamic stability

± 5% in 10 ms

Voltage distortion

< 1% with linear load / < 3% with non-linear load

Crest factor

3:1 lpeack/lrms

Frequency stability on battery

0.05%

Frequency

50 or 60 Hz (selectable)

Overload

110% for 60’; 125% for 10’; 150% for 1’

BATTERIES Type

VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels

Residual ripple voltage

< 1%

Temperature compensation

-0.5 Vx°C

Typical charge current

0.2 x C10

INFO FOR INSTALLATION Weight without batteries (kg)

200

220

230

Dimensions (WxDxH) (mm)

270

302

555 x 740 x 1400

Remote signals

440

500

800 x 740 x 1400 dry contacts

Remote controls

ESD and bypass

Communications

Double RS232 + dry contacts + 2 slots for communications interface

Operating temperature

0 °C/ +40 °C

Relative humidity

<95% non-condensing

Colour Noise level at 1 m IP rating Smart Active efficiency Standards Classification in accordance with IEC 62040-3 Moving the UPS BAT

580 800 x 800 x 1900

Dark grey RAL 7016 60 dBA

62 dBA IP20 up to 98%

Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3 (Voltage Frequency Independent) VFI - SS - 111 transpallet

Also available with internal batteries

www.riello-ups.com

87


MODELS

MPT 10 BAT

MPT 15 BAT

MPT 20 BAT

MPT 30

MPT 40

MPT 60

MPT 80

INPUT Nominal voltage

380 - 400 - 415 Vac three-phase

Voltage tolerance

400 V + 20% /- 25%

Frequency

45 - 65 Hz

Soft start

0 - 100% in 120’’ (selectable)

Permitted frequency tolerance

± 2% (selectable from ± 1% to ± 5% from front panel)

Standard equipment provided

Back Feed protection; separable bypass line

BYPASS Nominal voltage

360-400-420 Vac three-phase + N

Nominal frequency

50 or 60 Hz (selectable)

OUTPUT Nominal power (kVA)

10

15

20

30

40

60

80

Active power (kW)

9

13,5

18

27

36

54

72

460

540

Number of phases

3+N

Nominal voltage

380 - 400 - 415 Vac three-phase + N (selectable)

Static stability

± 1%

Dynamic stability

± 5% in 10 ms

Voltage distortion

< 1% with linear load / < 3% with non-linear load

Crest factor

3:1 lpeack/lrms

Frequency stability on battery

0.05%

Frequency

50 or 60 Hz (selectable)

Overload

110% for 60’; 125% for 10’; 150% for 1’

BATTERIES Type

VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels

Residual ripple voltage

< 1%

Temperature compensation

-0.5 V/°C

Typical charge current

0.2 x C10

INFO FOR INSTALLATION Weight without batteries (kg) Dimensions (WxDxH) (mm)

228

241

256

335

800 x 740 x 1400

Remote signals

dry contacts

Remote controls

ESD and bypass

Communications

Double RS232 + dry contacts + 2 slots for communications interface

Operating temperature

0 °C / +40 °C

Relative humidity

<95% non-condensing

Colour Noise level at 1 m IP rating Smart Active efficiency Standards Classification in accordance with IEC 62040-3 Moving the UPS BAT

88

315

555 x 740 x 1400

Also available with internal batteries

Dark grey RAL 7016 60 dBA

62 dBA IP20 up to 98%

Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3 (Voltage Frequency Independent) VFI - SS - 111 transpallet


MODELS

MPT 100

MPT 120

MPT 160

MPT 200

MPT 800

INPUT Nominal voltage

380 - 400 - 415 Vac three-phase

Voltage tolerance

400 V + 20% /- 25%

Frequency

45 - 65 Hz

Soft start

0 - 100% in 120’’ (selectable)

Permitted frequency tolerance

± 2% (selectable from ± 1% to ± 5% from front panel)

Standard equipment provided

Back Feed protection; separable bypass line

BYPASS Nominal voltage

360-400-420 Vac three-phase + N

Nominal frequency

50 or 60 Hz (selectable)

OUTPUT Nominal power (kVA)

100

120

160

200

800

Active power (kW)

90

108

144

180

640

Number of phases

3+N

Nominal voltage

380 - 400 - 415 Vac three-phase + N (selectable)

Static stability

± 1%

Dynamic stability

± 5% in 10 ms

Voltage distortion

< 1% with linear load / < 3% with non-linear load

Crest factor

3:1 lpeack/lrms

Frequency stability on battery

0.05%

Frequency

50 or 60 Hz (selectable)

Overload

110% for 60’; 125% for 10’; 150% for 1’

BATTERIES Type

VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels

Residual ripple voltage

< 1%

Temperature compensation

-0.5 V/°C

Typical charge current

0.2 x C10

INFO FOR INSTALLATION Weight (kg)

600

Dimensions (WxDxH) (mm)

610

690

790

800 x 800 x 1900

Remote signals

dry contacts

Remote controls

ESD and bypass

Communications

Double RS232 + dry contacts + 2 slots for communications interface

Operating temperature

0 °C / +40 °C

Relative humidity

<95% non-condensing

Colour Noise level at 1 m IP rating Smart Active efficiency Standards Classification in accordance with IEC 62040-3 Moving the UPS

5300 4400 x 1000 x 1900

Dark grey RAL 7016 65 dBA

68 dBA

77 dBA

IP20 up to 98% Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3 (Voltage Frequency Independent) VFI - SS - 111 transpallet

www.riello-ups.com

89


VFI TYPE

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

Master HP 3:3 100-600 kVA

6

SmartGrid ready

Supercaps UPS

Flywheel compatible

Service 1st start

Highlights

• High efficiency (up to 98.5%) • IGBT-based rectifier technology • Compact and reliable • Galvanic isolation • High overload capacity • LCD Display 90

The Master HP series from 100 to 600 kVA is the Riello UPS solution for installations requiring high energy efficiency and maximum power availability. Master HP Series provides maximum protection and power quality for data centres and industrial loads. The UPS has an IGBT-based rectifier, DSP (Digital Signal Processors) technology and provides true On-line, double conversion power protection, (VFI SS 11 - Voltage and Frequency Independent in accordance with IEC EN 62040-3).

Maximised cost savings The build specifications offered by the Master HP range and the exceptional level of efficiency help to absorb the TCO, from the installation stage to daily operation, reducing power costs for the UPS and air conditioning system and installation area costs thanks to its reduced size and weight. Thanks to the ability to monitor the mains input quality and to select the best operating mode based on the interference present (Smart Active mode) or circular redundancy (Parallel Energy Saving mode, which allows the UPS to regulate available


capacity based on the immediate demands of the load, automatically switching to standby in the event of excess capacity), the Master HP offers high levels of efficiency also for partial loads, resulting in reduced operating costs.

Power continuity For years, Riello UPS has developed and supplied solutions for dealing with the different requirements and problems that inevitably arise in critical applications. Riello UPS offers flexible, high-availability solutions that are able to adapt to different system structures and critical levels. Riello UPS creates UPS systems that can tolerate a number of component or subsystem failures, while continuing to operate normally, providing power without interruption. This is achieved by careful design, installing redundant elements, eliminating common failure points, scheduling maintenance activities and controlling and supervising the system operating parameters and environment. The TEC service team is ready to provide guidance and advice on projects.

Complete galvanic isolation Master HP UPS feature an output isolation transformer (on the inverter), inside the UPS cabinet, providing galvanic isolation of the load towards the battery and improved versatility in system configuration, allowing: • Complete galvanic isolation for medical applications and critical infrastructures • two truly separate network inputs (main and emergency), coming from two different power sources (with different neutrals); this is particularly well suited to parallel systems in order to ensure selectivity between the two sources, thus improving the reliability of the entire installation; • Installation in networks without neutral. Housing the transformer inside the cabinet allows for a significant reduction in the footprint, providing space savings.

• input power factor 0.99 • power walk-in function that ensures progressive rectifier start up • start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system. This provides savings in installation costs via: • a smaller electrical infrastructure. • smaller circuit protection devices • less wiring. Master HP also performs the role of a filter and power factor corrector, protecting the upstream power supply from any harmonics and reactive power generated by the consumers.

Flexibility Master HP is suitable for a wide range of applications including IT and the most demanding industrial environments and processes. With several operational configurations including On-Line, Eco, Smart Active, Stand By, Frequency Converter and Voltage Stabiliser. A broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the Riello UPS Group Synchroniser (UGS) and Parallel Systems Joiner (PSJ), sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability.

Master MPS models, which optimises battery performance in order to extend the battery life for as long as possible.

Main features • High efficiency (up to 98.5%) • Compact size: e.g.: only 0.85 m2 for the Master HP 250 kVA • Reduced weight • Double load protection, both electronic and galvanic, towards the battery. The entire Master HP range is suitable for use in a wide range of applications. Thanks to the flexibility of configuration, available options and accessories, it is suitable for supplying any type of load, e.g. capacitive loads such as blade servers etc. Power supply reliability and availability are ensured for critical applications by distributed or centralised parallel configurations of up to 8 units, for redundant (N+1) or power parallel configurations and all the different configurations offered by the Master MPS range.

Smart Grid Ready Being smart grid ready, Master HP allows for the implementation of power accumulation solutions, and at the same time ensures extremely high levels of efficiency. It is also able to independently select the most efficient operating method based on the status of the grid. Master HP UPS are also able to electronically interface with the energy manager using the smart grid communication network.

Specific solutions The UPS can be adapted to meet your requirements. Contact our TEC team to discuss specific solutions and options not listed in this catalogue.

Battery care system: maximum battery care The Master HP range uses the sophisticated Battery Care System, also available on the

Zero impact source

DIMENSIONS

800

0 85

MHT 300 MHT 400

MHT 500 MHT 600

1900 1000

0 85

1900

MHT 160 - MHT 200 MHT 250

1900

MHT 100 MHT 120

1900

The Master HP series features the added advantages of the Zero Impact Source formula offered by an IGBT-based rectifier assembly. This eliminates problems connected with installation in networks with limited power capacity, where the UPS is supplied by a generator set or anywhere there are compatibility problems with loads that generate current harmonics. Master HP series UPS have zero impact on the power supply source, whether it is a mains grid or generator set: • input current distortion < 3%

1500

00 10

2100

00 10

www.riello-ups.com

91


OPTIONS

DETAILS

Software PowerShield3 PowerNetGuard

MHT (detail of front) SWIN SWBYP

RS232-REPO Connectors Dry CONTACTS

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 56K Modem GSM Modem

FAN FUSES SWMB

COMMUNICATIONS INTERFACE SLOT

SWOUT

PARALLEL INTERFACE

UGS INTERFACE

MULTI I/O MODEM INTERFACE

REMOTE ALARM

PRODUCT ACCESSORIES Isolation transformer Synchronisation device (UGS): see Master MPS on page 84

Hot connection device (PSJ): see Master

NOTE : The layout of controls and connectors may vary based on the size of the UPS

MPS on page 84

Generator interface Parallel configuration kit (Closed Loop) Battery cabinets empty or for extended runtimes Top Cable Entry cabinets IP rating IP31/IP42

BATTERY BOX

CABINETS WITH TOP ACCESS FOR CABLES

UPS MODELS

MHT 100-600

Dimensions (mm)

BB

86 0

MODELS

TCE MHT 100-250

TCE MHT 300-600

MHT 100-250

MHT 300-600

Dimensions (mm) 1900

1900

UPS MODELS

TC E

0 80

27 0

0 80

TC E

40 0

0 85

1900

BB 1900 480-V6 / BB 1900 480-V7 BB 1900 480-V8 / BB 1900 480-V9

1900

MODELS

TC E

40 0

00 10

THREE-PHASE ISOLATION TRANSFORMERS

1900

Dimensions (mm)

64 0

92

TBX 200 T - TBX 250 T MPT 200 / MHT 200-250

0 80

TBX 300 T - TBX 600 T MHT 300-600

80 0

0 80

1900

TBX 100 T - TBX 160 T MPT 100-160 / MHT 100-160

1900

MODELS UPS MODELS

120 0

00 10


MODELS

MHT 100 MHT 120 MHT 160 MHT 200 MHT 250 MHT 300 MHT 400 MHT 500 MHT 600

INPUT Nominal voltage

380 - 400 - 415 Vac three-phase

Frequency

45 - 65 Hz

Power factor

> 0,99

Harmonic current distortion

<3% THDi

Soft start

0 - 100% in 120’’ (selectable)

Frequency tolerance

± 2% (selectable from ± 1% to ± 5% from front panel)

Standard equipment provided

Back Feed protection; separable bypass line

BYPASS Nominal voltage

360-400-420 Vac three-phase + N

Nominal frequency

50 or 60 Hz (selectable)

OUTPUT Nominal power (kVA) Active power (kW)

100

120

160

200

250

300

400

500

600

90

108

144

180

225

270

360

450

540

2100

2400

Number of phases

3+N

Nominal voltage

380 - 400 - 415 Vac three-phase + N (selectable)

Static stability

± 1%

Dynamic stability

± 5% in 10 ms

Voltage distortion

< 1% with linear load / < 3% with non-linear load

Crest factor

3:1 lpeack/lrms

Frequency stability on battery

0.05%

Frequency

50 or 60 Hz (selectable)

Overload

110% for 60’; 125% for 10’; 150% for 1’

BATTERIES Type

VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels

Ripple current

Zero

Recharge voltage compensation

-0.5 Vx°C

INFO FOR INSTALLATION Weight (kg)

656

700

Dimensions (WxDxH) (mm)

800 x 850 x 1900

800

910

1000

1000 x 850 x 1900

Remote signals

1400

1700

1500 x 1000 x 1900

2100 x 1000 x 1900

dry contacts (configurable)

Remote controls

ESD and bypass (configurable)

Communications

Double RS232 + dry contacts + 2 slots for communications interface

Operating temperature

0 °C / +40 °C

Relative humidity

<95% non-condensing

Colour Noise level at 1 m IP rating Smart Active efficiency Standards Classification in accordance with IEC 62040-3 Moving the UPS

Dark grey RAL 7016 63 - 68 dBA

70 - 72 dBA IP20 (others on request) up to 98.5%

Safety: EN 62040-1-1 (Directive 2006/95/EC); EMC: EN 62040-2 (Directive 2004/108/EC) (Voltage Frequency Independent) VFI - SS - 111 transpallet

www.riello-ups.com

93


VFI TYPE

DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY

ONLINE

Master HP UL 3:3 65-250 kVA

6

Flywheel compatible

UL certified

SmartGrid ready

Supercaps UPS

Service 1st start

Highlights

• High efficiency (up to 98.5%) • IGBT-based rectifier technology • Compact and reliable • Galvanic isolation • High overload capacity • North American voltage 94

The incredible levels of quality, reliability and energy savings offered by the Master HP range of UPS have been extended to include a 480 Vac - 60 Hz version, certified as UL, with power ratings from 65 to 250 kVA. IT department managers, facility managers and CTOs are under increasing pressure to achieve zero downtime and to size data centre or industrial installations to be flexible in the face of continuous changes and expansion. As the search for the most reliable and efficient power supply system becomes ever-increasingly critical, Riello UPS has been continuously investing in power solutions to meet the demands of a range of our clients; a commitment that resulted in the Master HP UL range.

More than just an innovative and technologically-advanced UPS, it is a leap into the future of three-phase technology. Thanks to its double conversion on-line technology based entirely on IGBT and digital signal processors (DSP), the Master HP UL range ensures maximum power supply protection and quality for any type of load, IT or industrial, in particular for mission critical applications, with VFI SS 111 classification (Voltage and Frequency Independent) in accordance with IEC EN 62040-3. This range was designed using a new configuration that includes an IGBT sinusoidal input rectifier instead of the conventional thyristor system.


Differently from other UPS technologies available on the market, double conversion technology with galvanic isolated output guarantees a quality power supply that is completely protected from all electrical anomalies at the input. Even in the event of serious power supply problems, the output power remains stable.

Zero impact source

Flexibility The output isolation transformer ensures the galvanic isolation of the load towards the battery and improved versatility in system configuration: it allows for two truly separate network inputs (main and emergency), coming from two different power sources; this is particularly suited to parallel systems in order to ensure selectivity between the two sources, thus improving the reliability of the entire installation.

56K MODEM GSM MODEM PRODUCT ACCESSORIES Isolation transformer

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100

Synchronisation device (UGS): see Master MPS on page 84

Hot connection device (PSJ): see Master MPS on page 84

Generator interface Parallel configuration kit (Closed Loop) Battery cabinets empty or for extended runtimes Top Cable Entry cabinets IP rating IP31/IP42

Dimensions MHT UL 65 - MHT UL 80 MHT UL 100 - MHT UL 125

MHT UL 160 - MHT UL 200 MHT UL 250

800

0

85

including manual bypass

MHT UL 160 - MHT UL 200 MHT UL 250

100

0

0

85

excluding manual bypass

1900

Master HP UL uses the Battery Care System, which optimises battery performance in order to extend the battery life for as long as possible.

Software PowerShield3 PowerNetGuard

1900

Battery Care System: maximum battery care

OPTIONS

1900

Master HP UL features the added advantages of the Zero Impact Source formula offered by an IGBT-based rectifier assembly. This eliminates problems connected with installation in networks with limited power capacity, where the UPS is supplied by a generator set or in any case anywhere there are compatibility problems with loads that generate current harmonics. Master HP UL has zero impact on the power supply source, whether it is a mains grid or generator set: • input current distortion < 3% • input power factor 0.99 • power walk-in function that ensures progressive rectifier start up • start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system. Master HP UL also performs the role of a filter and power factor corrector, protecting the upstream power supply from any harmonics and reactive power generated by the consumers.

1400

0

85

including manual bypass Top Cable Entry cabinets

www.riello-ups.com

95


MODELS

MHT UL 65

MHT UL 80 MHT UL 100 MHT UL 125 MHT UL 160 MHT UL 200 MHT UL 250

INPUT Nominal voltage

480 Vac three-phase + N

Frequency

45 - 65 Hz

Power factor

> 0.99

Harmonic current distortion

<3% THDi

Soft start

0 - 100% in 30’’ (selectable)

Frequency tolerance

± 2% (selectable from ± 1% to ± 5% from front panel)

Standard equipment provided

Back Feed protection; separable bypass line

BATTERIES Type

VRLA AGM / GEL; NiCd; Li-ion; Supercaps and Flywheel

Ripple current

Zero

Recharge voltage compensation

-0.5 Vx°C

OUTPUT Nominal power (kVA) Active power (kW)

65

80

100

125

160

200

250

58.5

72

90

112.5

144

180

225

Number of phases

3+N

Nominal voltage

480 Vac three-phase + N

Static stability

± 1%

Dynamic stability

from ± 5% to ± 1% in 20 ms

Voltage distortion

< 1% with linear load / < 3% with non-linear load

Crest factor

3:1 lpeack/lrms

Frequency stability on battery

0.05%

Frequency

60 Hz

Overload

110% for 60’; 125% for 10’; 150% for 1’

INFO FOR INSTALLATION Weight (lbs [kg]) Weight without manual bypass (lbs [kg])

1213 [550]

1433 [650]

1544 [700]

-

-

-

1984 [900]

2205 [1000]

2425 [1100]

Dimensions (WxDxH) (inches [mm])

31.5 x 33.5 x 75 [800 x 850 x 1900]

55 x 33.5 x 75 [1400 x 850 x 1900] *

Dimensions without manual bypass ‑(WxDxH) (inches [mm])

-

39 x 33.5 x 75 [1000 x 850 x 1900]

Remote signals

dry contacts (configurable)

Remote controls

ESD and bypass (configurable)

Communications

Double RS232 + dry contacts + 2 slots for communications interface

Operating temperature

0 °C / +40 °C

Relative humidity

<95% non-condensing

Colour Noise level at 1 m IP rating Smart Active efficiency Standards Classification in accordance with IEC 62040-3 Moving the UPS * with Top Cable Entry

96

2326 [1055] * 2546 [1155] * 2767 [1255] *

Dark grey RAL 7016 65 dBA

68 dBA IP20 (others on request) up to 98.5%

UL Standard 1778: 2nd edition from 65 to 125 kVA, 4th edition from 160 to 250 kVA; National Electrical Code (NFPA-70); NEMA PE-1; CUL - CSA C22.2; ASME; ASA-C-39.1-1984; FCC section 15 subsection J class A; NEC; OSHA; IEEE 587; ANSI C 62.41-1980; ISO 9000 (Voltage Frequency Independent) VFI - SS - 111 transpallet


www.riello-ups.com

97


VFI TYPE

INDUSTRY

ONLINE

TRANSPORT

Master Industrial 3:1 30-80 kVA

DC BUS 220 Vdc

4

Service 1st start

Highlights

Industrial application protection

• High short-circuit current

Master Industrial series UPS provide maximum protection and power quality for any type of load, especially industrial applications, such as manufacturing and petrochemical processes, electrical distribution and power plants. Master Industrial is an on-line double conversion UPS (class VFI SS 111 in accordance with IEC EN 62040-3) with input and output isolation transformers.

• Redundant ventilation

Industrial environment

• Battery voltage: 220 Vdc • Galvanic isolation of input and output

Master Industrial is suited to the most demanding installation environments where there are vibrations, mechanical stresses, dust 98

and in general where operating conditions are unfavourable to products created for the standard UPS market.

High ICC The high short-circuit current (ICC = 3) makes it suitable for loads that require high current peaks during switch-on or during normal operation.

DC voltage 220 V The input and inverter transformers guarantee the isolation of the batteries, which are sized for a voltage of 220 Vdc (from 108 to 114 elements), the standard industrial value.


OPTIONS

DIMENSIONS MIM 30 - MIM 40

Software & ACCESSORIES See Master MPS PRODUCT ACCESSORIES Isolation transformer Synchronisation device (UGS) Hot connection device (PSJ) Generator interface Parallel configuration kit (Closed Loop)

MIM 60 - MIM 80

1900

Redundant ventilation at 100% load is standard, ensuring operation with a normal load with half of the fans operating; in addition, each fan is monitored and an alarm signal is provided in the event of failure. The Easy Source input features, the Battery Care System, and the flexibility and communications capabilities are the same as those of the conventional Master MPS range (page 82).

1900

Redundant ventilation

Battery cabinets empty or for extended runtimes

0 80

800

1200

0 80

Top Cable Entry cabinets IP rating IP31/IP42

MODELS

MIM 30

MIM 40

MIM 60

MIM 80

INPUT Nominal voltage

380 - 400 - 415 Vac three-phase

Voltage tolerance

400 V ± 20%

Frequency

45 - 65 Hz

Power factor

> 0.93

Current distortion

< 6%

Soft start

0 ÷ 100% in 120’’ configurable

Permitted frequency tolerance

± 2% (selectable from ± 1% to ± 5% from front panel)

Standard equipment provided

Back Feed protection; separable bypass line; battery isolation

BATTERIES Type

VRLA AGM / GEL; NiCd

Number of cells

108/114

Maximum charging voltage

274 V

Temperature compensation

-0.5 Vx°C

OUTPUT Nominal power (kVA)

30

40

60

80

Active power (kW)

24

32

48

64

Nominal voltage

230 Vac single-phase

Static stability

± 1%

Dynamic stability

± 5%

Voltage distortion

< 1% with linear load / < 3% with non-linear load

Frequency

50 or 60 Hz (selectable)

Crest factor

3:1 lpeack/lrms

Overload

110% for 60’; 125% for 10’; 150% for 1’

Short-circuit current

3 I nom.

INFO FOR INSTALLATION Weight (kg) Dimensions (WxDxH) (mm)

640

650

910

800 x 800 x 1900

940 1200 x 800 x 1900

Remote signals

dry contacts

Remote controls

ESD and bypass

Communications

Double RS232 + dry contacts + 2 slots for communications interface

Operating temperature Relative humidity Colour Noise level at 1 m Ventilation IP rating Efficiency Standards Classification in accordance with IEC 62040-3 Moving the UPS

0 °C / +40 °C <95% non-condensing Light grey RAL 7035 68 ÷ 70 dBA Redundant fans (front-top) IP20 up to 94% Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3 (Voltage Frequency Independent) VFI - SS - 111 transpallet www.riello-ups.com

99


VFI TYPE

TRANSPORT

ONLINE

Master FC400 3:3 30-120 kVA

4

Service 1st start

Highlights

• Frequency converter 50/400 Hz • Output voltage: 208 V - 3F • Galvanic isolation • Applications: airport, military and naval

100

Master FC400 series static frequency converters are available from 30 to 120 kVA, with 50 or 60 Hz input and 400 Hz output. The result of extensive experience acquired in the UPS industry, the Master FC 400 series is distinguished by the use of technologically advanced components and for excellent reliability, ease of maintenance and ease of operation. The Master FC400 series uses double conversion technology (VFI SS 111 voltage and frequency independent compliant with IEC EN 62040-3), with an integrated output transformer to ensure the galvanic isolation of the load from mains disturbances under all conditions. The output voltage is 208 Vca three-phase

(200/115V versions upon request). Thanks to high frequency IGBT technology and digital control, Master FC400 frequency converters are ideal for airport, military and naval applications.

Minimum impact on mains – easy source The Master FC400 was designed to reduce to a minimum the impact on the mains or generator located upstream, thanks to the low harmonic content input and the progressive start of the rectifier. These features make the Master FC400 frequency converters especially compatible with generators.


DIMENSIONS

Applications Master FC400 provides additional protection for a wide range of applications, including: • Powering airplanes in airports • Radar and flight-control systems • Naval applications • Military applications • Power for test benches.

MFC 60 - MFC 80 MFC 100 - MFC 120

555

MFC 60 D - MFC 80 D MFC 100 D

0 74

0 80

800

0 80

1070

1900 0 80

1200

OPTIONS Software & ACCESSORIES See Master MPS

IP rating IP31/IP42 Parallel configuration kit (Closed Loop) Twelve-phase version (D) Filtering of 5th and 11th harmonics (HC) Top Cable Entry cabinets Generator interface

PRODUCT ACCESSORIES Input isolation transformer

MODELS

MFC 120 D

1900

MFC 30

1900

The Master FC400 requires a small space for installation (only 0.86m2 for a 120kVA model). The main assemblies of the UPS can be easily accessed for maintenance, via the removable front panel. Fans located in the top of the UPS cabinet, eliminate the need for side or rear access, and allow the UPS to be placed against a wall.

1400

Easy installation and maintenance

MFC 30

MFC 60

MFC 80

MFC 100

MFC 120

INPUT Nominal voltage

380 - 400 - 415 Vac three-phase

Voltage tolerance

400 V ± 20%

Frequency

45 - 65 Hz

Current distortion

< 5% C (HC Version)

Soft start

0 - 100% in 120’’ configurable

OUTPUT Nominal power (kVA)

30

60

80

100

120

Active power (kW)

24

48

64

80

96

Nominal voltage

208 Vac three-phase + N

Static stability

± 1%

Dynamic stability

± 5%

Voltage distortion

< 3% with linear load / < 4% with non-linear load

Frequency

400 Hz

Crest factor (lpeack/lrms)

3/1

Overload

110% for 60’; 125% for 10’; 150% for 1’

INFO FOR INSTALLATION Weight (kg) Dimensions (WxDxH) (mm)

330

480

555 x 740 x 1400

500

530 800 x 800 x 1900

Remote signals

dry contacts

Remote controls

ESD and ON/OFF

Communications

Double RS232 + dry contacts + 2 slots for communications interface

Operating temperature

0°C / +40°C (50°C @ 75% load)

Relative humidity

<95% non-condensing

Colour Noise level at 1 m IP rating

Light grey RAL 7036 62 dBA

65 dBA

68 dBA

70 dBA

72 dBA

IP20 (others on request)

Efficiency

up to 92%

Standards

Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3

Classification in accordance with IEC 62040-3 Moving the UPS

560

(Voltage Frequency Independent) VFI - SS - 111 transpallet www.riello-ups.com

101


DATACENTER

INDUSTRY

TRANSPORT

Master Static Bypass 3:3 800-3000 kVA

Service 1st start

Highlights

• Flexibility • The ideal solution for installations with UPS in parallel greater than 1 MVA • High system reliability • Centralised diagnostics

102

The centralised bypass is an alternative to the distributed bypass. Technically the two solutions fulfil the same purpose, i.e. to guarantee power continuity, but have different architectures. Whilst it is true that distributed bypass solutions are the most common due to their flexibility of use and low initial cost, it is also true that in the medium/large data centre market centralised bypass solutions are preferable in terms of technical performance, footprint and sometimes cost, above all in large installations where the number and type of protections as well as system wiring have an impact. The data centre and data-storage market in general is destined for large growth. It is therefore important to respond to the

various requirements with flexible solutions that are able to adapt to the growing demands of the market in terms of the levels of power and performance required.

Flexibility The Riello UPS centralised bypass (named MSB) is available in four standard power ratings: 800, 1200, 2000 and 3000 kVA. Intermediate solutions within this range can be made, as well as solutions greater than 3000 kVA based on the requirements of the customer or application. The MSB centralised bypass can be integrated with the Master HP range; in fact it can be associated with up to 7 UPS modules in the range, obviously without static bypass and associated bypass line


(named MHU). Based on requirements, MSB can also be compatible with the Master MPS range, thus ensuring complete flexibility aimed at satisfying all power and power supply requirements. Riello UPS provides the same flexibility as the Master HP for the battery bus, so that the MHU units can operate with both shared or separate batteries. The 800 kVA MSB is supplied with a comprehensive cabinet including bypass line input switch (SWBY), system output switch (SWOUT) and manual bypass (SWMB). The 1200 kVA model is supplied as standard without any switches but can be equipped with the same, suitably proportioned, switches provided for the 800 kVA model (SWBY, SWOUT, SWMB). The more powerful models are supplied with no switches; the bulky sizes of disconnection devices at these power levels are such as to favour tailor-made engineering solutions as an additional part of the system attestation and distribution cabinets where the centralised bypass and MHU modules are fitted.

the common points. Even minimal variations in the line impedances of the individual bypasses can cause current equipartition problems between the UPS and associated overcurrent in the cables whenever they supply from the bypass. This can lead to the inappropriate cut-in of protection devices and can generate heat, with the end result of minimising power continuity and increasing power consumption for cooling the system. The Riello UPS centralised bypass (MSB) is the ideal solution for eliminating all critical issues connected with power distribution over bypass lines. When activated, all power flows through a single static bypass module, ensuring: • High reliability • Improved energy efficiency • Exceptional ability to withstand shortcircuits downstream of the system • Centralised system control both with regards to accessibility to system information and with regards to manoeuvrability since the system is equipped with a single manual system bypass. By opting for the solution with a centralised bypass, the individual MHU units are provided without integrated static bypasses, thus eliminating critical components (static circuit and associated line protections such as disconnectors and/or fuses). This translates into a lower installation cost by eliminating the cables for the auxiliary power supply lines to the individual modules. These advantages grow exponentially as the power levels at play and number of modules increase. This is why the centralised bypass solution is technically and economically

The ideal solution for installations with UPS in parallel greater than 1 MVA Medium-high power systems are often comprised of N UPS of small-medium power ratings arranged in parallel. It is clear that the larger the size of the individual UPS modules or the number of units configured in parallel, the more complex and extensive the system wiring shall be. Particular attention should be paid to the length of the power lines for the individual UPS bypasses, so that they are equidistant from

preferable for power levels above one megawatt.

High system reliability When compared to a solution with a distributed bypass and a considerable number of UPS modules arranged in parallel (more than 4), the MSB solution significantly reduces the amount of components (SCR, switches, control elements for individual static bypasses, coupling inductances), consequently increasing system reliability.

Power supply from bypass line: “On Line” mode Recent design philosophies for data centres are pushing towards making systems operate on bypass lines not only in the event of an emergency, but as an alternative to “ON-Line” mode, thus improving system efficiency. For this reason power circulation through a single line (centralised bypass), eliminates all problems connected with current distribution, which must be ensured in the event of the operation of UPS modules in parallel with distributed by‑passes. The greater the power rating of the UPS, the exponentially greater the risk of minimal impedance differences in the bypass lines generating large imbalances in current circulation, with a serious risk of protection cut-in, compromising power supply continuity. With the centralised bypass the static circuit is single and independent and the current flows through a single channel, ensuring immunity from interaction problems between individual UPS units.

Parallel configuration of up to 8 UPS units with distributed bypass

Parallel configuration of up to 7 MHU units with CENTRALISED bypass

Parallel architecture to ensure redundancy of the power source. + Flexibility and modularity and no single point of failure.

Parallel architecture to ensure redundancy of the power source, with autonomous bypass management. + Selectivity of downstream faults in bypass mode Bypass mains

Bypass mains

Battery

MHU2

Mains MHU3...

MHU7

CENTRALIZED STATIC BY PASS (MSB)

Battery

MHU1

UPS3... UPS8

Battery

UPS2

Battery

Battery

UPS1

Mains

Mains

Mains

Battery

Mains

Mains

Maintenance Bypass Cabinet

Load

Load

www.riello-ups.com

103


DETAILS

Software PowerShield3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 56K Modem GSM Modem PRODUCT ACCESSORIES Top Cable Entry cabinets IP rating IP31/IP42 Manoeuvring switches

MHU (detail of front)

MSB (detail of front)

SWOUT SWOUT

SWMB SWBYP

see master HP

SWIN

DIMENSIONS MSB 1200

MSB 2000

1900

MSB 800

1000

104

The use of the MSB centralised bypass centralises the diagnostics and control of the bypass line. The display provides information concerning the voltage and current supplied and the status of the individual UPS modules (MHU). Differently from a system with distributed bypass, the centralised bypass is equipped with a single disconnection device for the bypass line and can be provided with an integrated manual bypass. The single disconnection device guarantees that the manoeuvres are carried out quickly and with a minimum margin of error, guaranteeing once again improved system reliability. The MSB bypass provides dedicated housings for the various remote control systems such as: three-contact relay board (standard), two communications slots and full compatibility with the communications interfaces in the Riello UPS range for UPS in the MHT / MPT ranges.

0 85

1400

00 10

MSB 3000

1900

OPTIONS

Centralised diagnostics

1900

The static bypass is a support device aimed at ensuring power continuity in the event of inverter failure. In the event of N UPS configured in parallel the failure of a single inverter module should automatically exclude it from the parallel system, ensuring the correct operation of the other units and the reliability of the system. For this reason automatic switching to bypass lines takes place only when there is a serious fault with the inverter or due to external forces, such as a short circuit downstream of the system. These events are both rapid and unpredictable and, based on the power available on the line, can generate short circuit currents that can be extremely high. In the event of distributed parallel configurations where N static by‑passes are arranged in parallel, minimal differences (even in the order of fractions of a millisecond), can generate uncontrolled transients and current flow between UPS units such as to trigger protection devices or

even damage the bypass thyristors. Riello UPS are equipped with sophisticated parallel control logics that ensure synchronism between the various units arranged in parallel under all operating conditions. The Riello MSB centralised bypass in any case ensures complete immunity from any problem connected with switching synchronism between modules even in the most extreme cases as long as the static module is single and independent. In addition, differently from a distributed parallel configuration of the same power rating, the centralised bypass can be oversized to guarantee increased overload capacity and the ability to withstand short circuits. The ventilation system for the MSB static bypass is designed to guarantee operation even in the event of the failure of several fans. In order to constantly monitor the status of the fans, a control circuit can be provided to control the operation of each individual ventilation fan.

1900

Power supply from bypass line: in an emergency

2600

00 10

3400

00 10


MODELS

MSB 800

MSB 1200

MSB 2000

MSB 3000

800

1200

2000

3000

OPERATING SPECIFICATIONS Nominal power (kVA) Nominal voltage

380 - 400 - 415 Vac three-phase + N

Input voltage tolerance

± 15% (selectable from ± 10% to ± 25% from front panel)

Frequency

50/60 Hz

Frequency tolerance

± 2% (selectable from ± 1% to ± 6% from front panel)

Standard equipment provided

Back Feed protection

Permitted overload*

110% for 60 min; 125% for 10 min; 150% for 1 min

ENVIRONMENTAL SPECIFICATIONS Noise at 1 m from front (from 0 to full load)

< 65 dBA

Storage temperature

-10 °C up to +50 °C

Operating temperature

O °C - 40 °C

Relative humidity

95% non-condensing

Max. installation height

1000 m at nominal power (-1% power for every 100 m above 1000 m) - Max 4000 m

Reference standard

EN 62040-1 general safety requirements; IEC 62040-2 electromagnetic compatibility

INFO FOR INSTALLATION Weight (kg) Dimensions (WxDxH) (mm) Communications

570 1000 x 850 x 1900

800

1200

2000

** 1400 x 1000 x 1900

2600 x 1000 x 1900

3400 x 1000 x 1900

Double RS232 + dry contacts + 2 slots for communications interface

Colour

Dark grey RAL 7016

IP rating

IP20 (others on request)

Moving the UPS * under certain conditions

transpallet ** 1800 mm version with switches

www.riello-ups.com

105


DATACENTER

Multi Switch 1:1 16 A

Plug & Play installation

Highlights

Ouput 1 Max 4 A

• Redundant power supply

Ouput 2 Max 4 A

• Load protection

Ouput 3

• Versatile to use

Max 4 A

Ouput 4 Input 1

Max 4 A

Ouput 5 Input 2

Max 4 A

Ouput 6 Max 4 A

Ouput 7

Multi Switch is a rackmount source transfer switch that can supply up to eight loads from two AC power sources. Should one source fail, the other automatically powers the load. The sources can be two separate AC sources including mains power and UPS, or a combination of the two.

Operating principle The Multi Switch provides electrical distribution and remote management for up to eight network users, powered from two direct mains supplies or UPS or a combination of both. The Multi Switch can connect each load (up to eight, each with a maximum power demand not greater than 4A), to either of the two power sources (1 and 2). Load demand is shown on the LCD.

Max 4 A

Protection against load faults Ouput 8 Max 4 A

106

If one of the two loads fails (i.e. due to a short circuit or overload), Multi Switch will disconnect the load to protect the operation


of the other loads (i.e. in the event of poor selectivity of the protection devices).

Protection against power supply faults

DETAILS MSW (2 inputs - 8 outputs) FRONT

OUTPUT SOCKETS

If one of the two power sources falls outside tolerance levels, Multi Switch will transfer the consumers to the second power source (switching is instantaneous if the two sources are in phase).

Features

version “N” ETHERNET

version “S” SerialE RS232 INPUT THERMAL PROTECTION

REAR

• Full protection for consumers against mains and load failures • Versatile to use: can be powered with 2 different power supplies (2 UPS even of different sizes/types) • 19” cabinet installation • LCD display for monitoring measurements / alarms / status • Can be connected to PowerNetGuard supervision software (Ethernet version) • No signal connection between the Multi Switch and the power sources or consumers is necessary • Display software • Network interface.

MODELS

INPUT SOCKETS

OPTIONS Software PowerNetGuard ACCESSORIES NETMAN 102 PLUS (only with version N)

MSW-S

MSW-N

CURRENT

16 A

INPUT Nominal voltage

180 - 276 Vac

Nominal frequency

50/60 Hz

Max. load for each input

16 A

Input sockets

2 IEC 320 (16 A)

OUTPUT Nominal voltage

choice of one of the two input power sources

Max. load for each output

4A

Output sockets

8 IEC 320 10 A

INFO FOR INSTALLATION Weight (kg)

10

Dimensions (WxDxH) (mm)

19” x 360 x 2U

Operating temperature

0 °C / +40 °C

Relative humidity Protections

<95% non-condensing Overcurrent - overvoltage - undervoltage - protection against energy back-feed

Max. altitude

3000 m

Max. altitude (in storage conditions) Communications Colour IP rating Noise level at 1 m

6000 m; 45 °C RS232 port

Ethernet port Dark grey RAL 5004 IP20 < 35 dBA www.riello-ups.com

107


DATACENTER

Multi Switch ATS 1:1 16 A

Plug & Play installation

• Redundant power supply

Multi Switch ATS provides installations with power supply continuity. Its operating principle ensures higher reliability than a single UPS, (with or without its own internal bypass).

• Load protection

Operating principle

Highlights

• Versatile to use

Multi Switch ATS provides direct distribution of eight 10 A IEC consumers or one 16 A IEC consumer in a system with two input power lines (two mains inputs, or two UPS). Multi Switch ATS is able to connect to either of the two input power lines, whilst simultaneously monitoring the power uptake.

Protection against load faults If one of the loads fails (e.g. short circuit), Multi Switch ATS disconnects the group of sockets where the load is connected, thus 108

Ouput 1 Max 10 A

Input 1

Input 2

Ouput 2 Max 10 A

Ouput 3 Max 10 A


preventing other loads from being switched off (i.e. in the event of poor selectivity of the protection devices).

Protection against power supply faults

DETAILS MTA

ON/OFF SWITCHES

FRONT

OUTPUT THERMAL PROTECTION

If one of the two power sources falls outside tolerance levels, Multi Switch ATS will transfer the consumers to the second power source (switching is instantaneous if the two sources are in phase).

Features • Full protection for consumers against mains and load failures • Versatile to use: Multi Switch ATS can be powered with 2 different power supplies (2 UPS even of different sizes/types) • 19” cabinet installation • Display panel • Can be connected to PowerNetGuard supervision software • No signal connection between the Multi Switch ATS and the power sources or consumers is necessary • Compatible with PowerShield3 software • Slot for communications boards.

COMMUNICATIONS INTERFACE SLOT RS232 SERIAL USB

REAR

TERMINAL BOARD OUTPUT SOCKETS

INPUT SOCKETS

OPTIONS Software PowerShield3

NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS

MODELS

MTA

CURRENT

16 A

INPUT Nominal voltage Nominal frequency Max. load for each input Input sockets

180 - 276 Vac 50/60 Hz 16 A 2 IEC-320 C20 (16 A)

OUTPUT Nominal voltage Max. load for each output Output sockets

choice of one of the two input power sources 10 A on IEC-320 C13 - 16 A on IEC-320 C19 4+4 IEC-320 C13 (10 A) + 1 IEC-320 C19 (16 A)

INFO FOR INSTALLATION Weight (kg) Dimensions (WxDxH) (mm) Operating temperature Relative humidity Protections Max. altitude Max. altitude (in storage conditions) Communications Colour IP rating Noise level at 1 m

6 19” x 330 x 1U 0 °C / +40 °C <95% non-condensing Overcurrent - overvoltage - undervoltage - protection against energy back-feed 3000 m 6000 m; 45 °C DB with RS232 and USB ports, slot for communications interface, relay contact port Dark grey RAL 5004 IP20 < 35 dBA www.riello-ups.com

109


DATACENTER

E-MEDICAL

INDUSTRY

TRANSPORT

Master Switch STS Single-phase 1:1 32-63-120 A

Plug & Play installation

• Complete diagnostics

Master Switch Single-phase (MMS) is part of the Master Switch range and offers solutions suitable for protecting single-phase loads with different power ratings. MMS is available in three sizes - 32, 63 and 120 A - and is therefore able to satisfy various requirements for the protection of singlephase loads.

• Hot Swap function

Flexibility of use

Highlights

• Operating flexibility • Load protection

All MMS versions are designed with criteria that facilitate on-site installation as well as diagnostics, control and maintenance operations. All models are equipped with a manual bypass and the hot swap function allows for rapid corrective interventions by non-specialised personnel in the event of faults.

Load protection With MMS transfer switch loads are protected against critical environmental situations and mains power interference. Microprocessor control and the use of thyristor static switches ensure continuous 110

monitoring of the power supply sources and reduced switching times between the two sources in the event of a fault. The constant monitoring of the output current allows for the rapid identification of any short circuit currents in the consumers, preventing short circuits from propagating to other loads. MMS is equipped with thermal-magnetic protection for the two sources, ensuring rapid intervention in the event of faults and integrated back feed protection. MMS ensures switching times between the two power sources of less that a quarter of a cycle, both in the event of manual switching and in the event automatic switching triggered by a fault in the power source.

Complete diagnostics All MMS versions are equipped with 32-character LCD displays and control panels with multi-function keys. This allows for rapid and intuitive monitoring of supply readings, switch status and environmental conditions. MMS is equipped with three standard programmable dry contacts, an


MODELS NOMINAL CURRENT (A)

MMS 32

MMS 63

MMS 120

32

63

120

INPUT Nominal voltage - sources S1/S2

220 - 230 - 240 Vac single-phase + N

Input voltage tolerance

180-264 Vac (selectable)

Switched input phases

ph+N (two poles)

Nominal frequency

50/60 Hz

Input frequency tolerance range

+/-10% (selectable)

Distribution compatibility

IT, TT, TNS, TNC

OPERATING SPECIFICATIONS Transfer type

“Break Before Make” (no overlapping sources)

Intervention method in the event of failure

hot swap function

Available transfer methods

Automatic / Manual / Remote

Transfer time following source failure

< 4 msec (S1/S2 synchronised) 10 msec (S1/S2 non synchronised)

ENVIRONMENTAL SPECIFICATIONS Efficiency at full load

> 99%

Noise at 1 m from front (from 0 to full load)

< 40 dBA

Storage temperature

-10 °C up to +50 °C

Operating temperature

O °C - 40 °C

Relative humidity Max. installation height

90% non-condensing 1000 m at nominal power (-1% power for every 100 m above 1000 m) - Max 4000 m

Reference standard

EN 62310-1 (safety) EN 62310-2 (electro-magnetic compatibility)

INFO FOR INSTALLATION Weight (kg) Dimensions (WxDxH) (mm)

10

12 19” x 520 x 2U

Colour

IP 20

DIAGRAM SERIAL RS232

FRONT

ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352

REPO CONNECTORS WITH Dry CONTACTS LED MIMIC PANEL

OPTIONS Software PowerShield3 PowerNetGuard

19” x 520 x 3U RAL 7016

IP rating

input for emergency shutdown, a 232 serial connection and a slot for housing the expansion board, thus ensuring complete availability of interface solutions for remote control and monitoring.

20

MAINTENANCE BYPASS

COMMUNICATIONS INTERFACE SLOT

BACK

INPUT SWITCH (SWIN) S1 INPUT SWITCH (SWIN) S2

IN/OUT TERMINAL BOARD

www.riello-ups.com

111


DATACENTER

E-MEDICAL

TRANSPORT

EMERGENCY

Master Switch STS Three-phase 3:3 100-600 A

Service 1st start

Highlights

• High reliability • Hot Replacement function • 3- or 4-pole version • Advanced communications

112

Installing a Master Switch static transfer switch provides additional resilience and protection from the disruption that can be caused by the failure of a single power source. The result is the absolute protection of industrial utilities and critical information technology against power supply and load faults.

Operating principle Master Switch guarantees a source of redundant power, allowing the load to be switched between to alternative and independent power sources. Switching can be automatic (when a supply source falls outside of acceptable

tolerances) or manually done by an operator from the front panel or remotely.

Protection against power supply faults If one of the two power sources falls outside tolerance levels, Master Switch will transfer the consumers to the second power source (switching is instantaneous if the two sources are in phase).

Protection against environmental disturbances Overloads and load faults In the event of an overload, the user can decide the level of intervention of the internal protection devices in order to block


Redundant design Power is supplied to the internal logic by two physically separate supply circuits that are fully independent and that can be replaced in “hot replacement” mode without causing power supply interruptions to the load. In the event that the power supplied by both sources fails, full system operation is guaranteed by the “Power Supply back up” function, which provides auxiliary power supply to the circuits from an external, independent power source. Master Switch is equipped with a dual redundant ventilation system known as: “fan redundance plus”. Thanks to this feature, and in the unlikely event that two fans fail at the same time, those remaining would still be able to dissipate the heat generated at nominal load and with an ambient temperature of up to 40° C. Also the fans can be replaced in “hot replacement” mode, ensuring continuity during the replacement operation.

Superior protection In the event of an output short circuit, Master Switch blocks the transfer between the two power sources, eliminating the risk of propagating the short circuit and its effects to the other loads. A back feed control circuit ensures the

LEDs

Input MCCB 1

Accessibility

Input MCCB 2

S2

The layout of the moving components and parts is designed to ensure easy frontal access: • power cable connections that are easily accessed with entry from below • boards housed in a dedicated area for rapid diagnosis / replacement • all parts subject to monitoring, maintenance and/or replacement.

S1

Maintenance Switch 2

Maintenance Switch 1

S4-2

SS2

SS1

S4-1

Output Switch 1

S3

Advanced communications

3P + N Output

Master Switch provides information, measurements, statuses, and alarms via the LCD display. The STS is compatible with PowerShield3 supervision and shutdown software for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X and Sun Solaris.

OPTIONS Software PowerShield3

PRODUCT ACCESSORIES RS232 serial duplicator “no neutral on input” kit IP rating IP31

ACCESSORIES NETMAN 101 PLUS multicom 301 multicom 351

DIMENSIONS MTS 100 MTS 150

MTS 200 - MTS 250 MTS 300 - MTS 400

685

0 53

MTS 600

1900

Microprocessor control logic ensures: • Fast and safe switching between power sources • Monitoring of all parameters via LCD display • Constant monitoring of SCR operation • Advanced remote diagnostics (RS232 and TCP/IP).

3P + N Source 2 Input

1770

Total microprocessor control

3P + N Source 1 Input

automatic intervention of the protection devices when a return of power to one of the two Master Switch inputs is detected.

1500

the power supply. In the extreme case of a downstream short circuit, Master Switch disconnects the load in order to avoid jeopardising the operation of the other loads (i.e. in the event of poor selectivity of the protection devices).

685

0 58

950

0 73

FUNCTION

L1

S1 Priority Source

L2

S2 Priority Source

L3

S1 Present

L4

S2 Present

L5

Static transfer switch SS1 closed

L6

Static transfer switch SS2 closed

L7

Alarm indicator

L8

Output selector ON/OFF

5 function keys and LCD operation www.riello-ups.com

113


MASTER SWITCH in REDUNDANT mode The secondary power source [AS], although highly reliable, only powers the load in the event of a failure with the priority power source [PS], ensuring maximum redundancy and power quality to the loads.

[PS]

[AS]

USER 1

[AS] = Secondary [PS] = Priority

MASTER SWITCH in CROSS FEEDING Mode The two sources power critical loads using Master Switches configured to selected one of the two power sources as the priority source [PS]. In case of a failure in one of two sources, the other will be able to supply power to all the loads connected to the system).

[PS]

[AS]

USER 1 [AS]

[PS]

[AS] = Secondary [PS] = Priority

USER 2

MASTER SWITCH in BACK-UP mode Independent separate lines

Master Switches power utilities via the priority energy source [PS]; the secondary energy source [AS] is made up of independent, separate power sources and to make up for any faults in the priority power source [PS].

[PS]

[AS]

USER 1 [PS]

[AS]

[AS] = Secondary [PS] = Priority

USER 2

DYNAMIC DUAL BUS CONFIGURATION Bypass 1

System B Mains

Mains

UPS2A

UPS2B

UGS Sinchroniser

Static Transfer SWITCH

Load 3 Load 1

Static Transfer SWITCH

Load 4

114

Mains

UPS1B

Battery

UPS1A

Bypass 2

Battery

Mains

Battery

System A

Battery

The Riello UPS solution guarantees maximum reliability and ensures continuity of power supply under all operating conditions thanks to the UGS option that keeps the two systems, A and B, perfectly synchronised. The flexibility of the UGS system ensures synchronism between the sources even when one of the two systems is not a Riello UPS model, but made by another manufacturer, or when the input sources are not from uninterruptible power supplies.

Load 2


MODELS NOMINAL CURRENT

MTS 100

MTS 150

MTS 200

MTS 250

MTS 300

MTS 400

MTS 600

100 A

150 A

200 A

250 A

300 A

400 A

600 A

55 dBA

57 dBA

INPUT Nominal voltage - sources S1/S2

380 - 400 - 415 Vac three-phase + N

Input voltage tolerance

180-264 Vac (selectable)

Switched input phases

3+N (4-pole) - 3 (3-pole)

Nominal frequency

50/60 Hz

Input frequency tolerance range

+/-10% (selectable)

Distribution compatibility

IT, TT, TNS, TNC

OPERATING SPECIFICATIONS Transfer type

“Break Before Make” (no overlapping sources)

Available transfer methods

Automatic / Manual / Remote

Transfer time following source failure

< 4 msec (S1/S2 synchronised) 10 msec (S1/S2 non synchronised)

ENVIRONMENTAL SPECIFICATIONS Efficiency at full load Noise at 1 m from front (from 0 to full load)

> 99% 55 dBA

55 dBA

55 dBA

Storage temperature

55 dBA

55 dBA

-10 °C up to +50 °C

Operating temperature

O °C - 40 °C

Relative humidity

95% non-condensing

Max. installation height

1000 m at nominal power (-1% power for every 100 m above 1000 m) - Max 4000 m

Reference standard

EN 62310-1 (safety) EN 62310-2 (electro-magnetic compatibility)

INFO FOR INSTALLATION Weight (kg) Dimensions (WxDxH) (mm) Colour IP rating Moving the STS

155

160

685 x 530 x 1500

205

210

235

685 x 580 x 1770

240

375 950 x 730 x 1900

RAL 7016 IP 20 transpallet

www.riello-ups.com

115


Power solutions SuperCaps UPS Solutions with supercaps

DATACENTER

E-MEDICAL

INDUSTRY

Highlights Extended lifecycle Thanks to the high number of chargedischarge cycles provided by the supercapacitors (millions or more with respect to the 200 or 300 of lead batteries), the lifecycle is similar to that of a UPS, making this an eco-friendly solution.

Reduced footprint and weight 1/4 size of conventional UPS.

High cycling efficiency Extremely low internal resistance (ESR) with consequent high cycling efficiency (95% or more) and low heat emission.

High temperature resistance UPS SuperCaps are suitable for installation in particularly hot and cold environments without the need for air conditioning.

SuperCaps module

Riello SuperCaps UPS are designed to provide complete power supply protection for sensitive and mission-critical loads, protecting them from mains disturbances and providing sufficient power to compensate for interruptions in mains supply. SuperCaps UPS are a type of uninterruptible power supply developed by Riello UPS , which use super capacitors to accumulate energy instead of conventional batteries. Traditionally UPS rely on batteries for accumulating energy, but at least 87% of power supply interruptions last for less than a second(1). SuperCaps UPS provide greater energy efficiency, lower costs and reduced footprints – ideal for installations where floor space is at a premium. At the heart of the Riello SuperCaps UPS is a sophisticated control system that manages the charge-discharge cycle of the supercapacitors and optimises their lifecycle, which may exceed a million cycles. Their back-up time is dependent on the load but is sufficient to supply it until the mains power is restored or until reserve power from a generator starts automatically.

(1)

116

Electric Power Research Institute study

Most UPS are installed as standard with batteries lasting 5-10 minutes to protect the load against generator start up failure. For modern data centres, electro-medical and industrial applications, an efficient generator set supported by a UPS with a relatively brief autonomy offers the most efficient and effective power continuity solution, with conventional batteries providing sufficient runtime to cover most power interruptions. However, SuperCaps UPS do not have batteries and therefore provide long term savings in terms of battery installation, monitoring, maintenance, replacement and recycling costs. In addition, when compared to the 5-7 year lifecycle of standard batteries, SuperCaps UPS have a theoretically infinite lifecycle. These cost savings, along with the reduced footprint make SuperCaps UPS the ideal solution for critical installations that are particularly sensitive to short power supply interruptions.


SENTINELPROSC MODELS INPUT

SEP 700 SC

SEP 1000 SC

Nominal voltage

220-230-240 Vac 1ph

Nominal frequency

50/60 Hz

Power factor

> 0.99 ≤7%

Current distortion OUTPUT

Nominal power (VA)

700

Power (W)

560

Autonomy

16 s

2200

800

1780

11 s

Recharge time (min)

DATA

1000

220-230-240 Vac 1ph

Nominal voltage BACKUP

SEP 2200 SC

11 s

15-30 min

Expandability

no

yes

yes

Net weight (kg)

8

8,1

17,6

Dimensions (WxDxH) (mm)

422 x 235 x 158

446 x 333 x 190

SENTINELPOWERSC MODELS INPUT

SPW 6000 SC Nominal voltage

SPT 8000 SC

220-230-240 Vac 1ph or 380-400-415 Vac 3ph

220-230-240 Vac 1ph

Nominal frequency

50/60 Hz

Power factor

> 0.99 ≤5%

Current distortion OUTPUT

Nominal power (VA)

6000

8000

10000

Power (W)

4800

6400

8000

220-230-240 Vac 1ph

Nominal voltage BACKUP

Autonomy

11 s

9s

7s

15-30 min

Recharge time DATA

SPT 10000 SC

Net weight (kg)

61

62

Dimensions (WxDxH) (mm)

64

785 x 615 x 282

MULTISENTRYSC MST 10 SC

MODELS INPUT

MST 12 SC

Nominal voltage

MST 15 SC

MST 20 SC

0.99

Current distortion

≤ 3%

MST 80 SC

MST 100 SC

MST 120 SC

Nominal power (VA)

10

12

15

20

30

40

60

80

100

120

Power (W)

9

10.8

13.5

18

27

36

54

72

90

108

Autonomy

220-230-240 Vac 1ph / 380-400-415 Vac 3ph 19 s

15 s

12 s

9s

14 s

123

128

133

138

171

Recharge time DATA

MST 60 SC

50/60 Hz

Power factor

Nominal voltage BACKUP

MST 40 SC

220-230-240 Vac 1ph / 380-400-415 Vac 3ph

Nominal frequency

OUTPUT

MST 30 SC

Net weight (kg) Dimensions (WxDxH) (mm)

9s

5s

7s

15 s

12 s

190*

200*

220*

380*

6-8 min

850 x 1320 x 440

163

850 x 1600 x 500

855 x 1900 x 750

* Supercaps are not included in the UPS cabinet

MASTERHPSC

contact our TEC service for configurations.

www.riello-ups.com

117


Power solutions Master VDC Flywheel solutions

3:3 100-600 kVA modular

DATACENTER

E-MEDICAL

TRANSPORT

EMERGENCY

Flywheel compatible

INDUSTRY

Service 1st start

Highlights CLEAN ENERGY An eco-friendly, battery-free uninterruptible power system.

High efficiency innovative technology Modular expansion options for more power and runtime.

Long operating life 20 year design life for the flywheel component compared with 7 years for a typical battery.

Low maintenance costs Easy to install and maintain.

118

Master VDC is a scaleable system comprised of one or more UPS units and VDC or VDC-XE flywheels. Master VDC is ideal for modern ECO targeted data centres looking to achieve the lowest possible PUE ratios and highest levels of reliability. Master VDC UPS provide a number of advantages over more traditional batteryequipped systems including: up to 99% efficiency, a compact footprint (up to 50% reduction), lower Total Cost of Ownership (TCO) and almost instantaneous recharge times. A single flywheel module provides sufficient runtime for the start-up of a local standby generator to power the UPS, which then provides a continuous quality power supply. The entire system can be scaled for reliable power (N+x) and increased runtime via the parallel operation of several UPS and/or flywheel modules (and a small battery pack if required, for additional reliability). In a standard configuration (1 x UPS and 1 x flywheel), the runtime available is more than sufficient to allow the UPS to ride through short breaks in mains power.

Flywheel VDC and VDC-XE Thanks to their extremely high levels of reliability, the VDC series of flywheel energy storage systems provide UPS with a secure and reliable source of power that forms the first line of defence against interruptions to the mains power supply; a fundamental defence for all mission critical applications. The VDC flywheel systems are fully independent standalone devices. They are designed for applications such as data centres, hospitals and industrial installations. They provide a clean source of back up power by converting the kinetic energy stored within a rotating mass into electrical power using a built-in IGBT-based converter. VDC flywheel systems are available in two models, VDC standard and VDC-XE, which is able to provide superior performance for very short and very high power discharges. VDC series flywheels store kinetic energy in the form of a rotating mass (spinning at 36,000 RPM) within a vacuum-sealed container. The VDC build technology includes a rotor made from aerospace-grade steel,


Master VDC CONFIGURATIONS MODULARITY 100kVA UPS

VDC FLYWHEEL

+

MHF 100

Autonomy: example with load at 100% :

+ VDC-XE FLYWHEEL

300kVA UPS

+

MHF 300

VDC FLYWHEEL

30s, 1xVDC 1m, 2xVDC

VDC-XE FLYWHEEL

Autonomy: example with load at 50% :

+

25s, 1xVDC-XE 52s, 2xVDC-XE

redundancy (parallel configurations n+1) 300kVA UPS

300kVA UPS

+

MHF 300P

VDC-XE FLYWHEEL

VDC-XE FLYWHEEL

+

+

Autonomy: example with load at 50% : 52s, 2xVDC-XE or 25s, 1xVDC-XE

N+1 Parallel UPS Configuration

BATTERY HARDENING

+

MHF 300

BATTERY BOX

VDC-XE FLYWHEEL

300kVA UPS

+

BB

Autonomy: example with load at 50% : 25s, 1xVDC-XE Plus 10 minutes from an additional battery set

a high speed permanent magnet motor/ generator and contact-free magnetic bearings that levitate and sustain the rotor during operation with no mechanical friction. These technical features allow VDC models to achieve very high levels of efficiency.

DIMENSIONS

1872

VDC / VDC-XE

762

2 76

www.riello-ups.com

119


Master VDC: UPS MODULE SPECIFICATIONS MODELS INPUT Nominal voltage Frequency Power factor Harmonic current distortion Soft start Frequency tolerance Standard equipment provided BATTERIES Type Ripple current Recharge voltage compensation OUTPUT Nominal power (kVA) Active power (kW) Number of phases Nominal voltage Static stability Dynamic stability Voltage distortion Crest factor Frequency stability on battery Frequency Overload INFO FOR INSTALLATION Weight (kg) Dimensions (WxDxH) (mm) Remote signals Remote controls Communications Ambient temperature Relative humidity Colour Noise level at 1 m IP rating Smart Active efficiency Standards Classification in accordance with IEC 62040-3 Moving the UPS

MHF 100 MHF 120 MHF 160 MHF 200 MHF 250 MHF 300 MHF 400 MHF 500 MHF 600 380 - 400 - 415 Vac three-phase 45 - 65 Hz > 0.99 <3% THDi 0 - 100% in 120’’ (selectable) ± 2% (selectable from ± 1% to ± 5% from front panel) Back Feed protection; separable bypass line Flywheels Zero -0.5 Vx°C 100 90

120 108

160 144

656 700 800 x 850 x 1900

800

200 180

250 300 400 225 270 360 3+N 380 - 400 - 415 Vac three-phase + N ± 1% ± 5% in 10 ms < 1% with linear load / < 3% with non-linear load 3:1 lpeack/lrms 0.05% 50 or 60 Hz (selectable) 110% for 60’; 125% for 10’; 150% for 1’

500 450

600 540

910 1000 1400 1700 2100 2400 1000 x 850 x 1900 1500 x 1000 x 1900 2100 x 1000 x 1900 dry contacts (configurable) ESD and bypass (configurable) Double RS232 + dry contacts + 2 slots for communications interface 0°C / +40°C <95% non-condensing Dark grey RAL 7016 63 - 68 dBA 70 - 72 dBA 70 dBA 70 dBA IP20 (others on request) up to 98.5% Safety: EN 62040-1-1 (Directive 2006/95/EC); EMC: EN 62040-2 (Directive 2004/108/EC) (Voltage Frequency Independent) VFI - SS - 111 transpallet

Master VDC: Flywheel MODULE SPECIFICATIONS MODEL POWER Maximum power Max. energy storage Flywheel rotation speed INPUT Recharge voltage Recharge current Efficiency OUTPUT Discharge voltage Voltage stability Voltage ripple INFO FOR INSTALLATION Ambient temperature Relative humidity Colour Noise level at 1 m Dimensions (WxDxH) (mm) Weight (kg) IP rating Standards 120

VDC

VDC-XE

215 kW 3000 kWsec @ 100 kW from 18500 to 36000 rpm

300 kW 4000 kWsec @ 100 kW from 14500 to 36750 rpm 400-600 Vdc 15-50 A (adjustable)

99.2% at max. power

99.4% at max. power 400-520 Vdc (adjustable) +/- 1% ≤ 2%

-2O°C / +40°C 95% non-condensing Dark grey RAL 7016 ≤ 68dBA 762 x 762 x 1872 705 IP 20 EMC EN 61000-6-4:2001; EMC EN 61000-6-2:2001; Safety EN 60204-1; Directives: 2004/108/EC; 98/37/EC


Master VDC: (Flywheel only) runtime IN seconds VDC 215 kW

MHF 100 MHF 120 MHF 160 MHF 200 MHF 250 MHF 300 MHF 400 MHF 500 MHF 600

Number of FLYWHEELS

Power

100

120

160

200

250

300

400

500

600

1

100%

30

22

13

7

-

-

-

-

-

2

60

50

37

29

20

14

7

-

-

3

89

74

55

44

35

29

18

11

6

4

118

98

73

58

46

39

29

19

13

5

147

123

92

73

58

48

36

29

20

100

120

160

200

250

300

400

500

600 -

Number of FLYWHEELS

Power

1

75%

41

34

22

15

9

-

-

-

2

80

66

50

39

31

24

14

8

-

3

119

99

74

59

47

39

29

20

14

4

157

131

98

78

62

52

39

31

23

5

197

164

123

98

78

65

48

39

32

100

120

160

200

250

300

400

500

600

Number of FLYWHEELS

Power

1

50%

62

51

38

30

21

15

7

-

-

2

120

100

75

60

47

39

29

20

14

3

179

149

112

89

71

59

44

35

29

4

263

197

147

118

94

78

58

46

38

5 Number of FLYWHEELS

Power

1

25%

295

246

184

147

118

98

73

58

48

100

120

160

200

250

300

400

500

600

29

101

76

60

48

40

29

16

14

2

263

196

147

118

94

78

58

46

38

3

350

292

219

175

140

116

87

69

57

4

461

385

289

231

185

154

115

92

76

5

576

481

361

289

231

192

144

115

95

VDC-XE 300 kW

MHF 100 MHF 120 MHF 160 MHF 200 MHF 250 MHF 300 MHF 400 MHF 500 MHF 600

Number of FLYWHEELS

Power

100

120

160

200

1

100%

250

300

400

500

600 -

40

33

22

15

9

5

-

-

2

79

65

49

39

30

24

14

8

-

3

118

98

73

58

46

38

28

20

14

4

156

129

97

77

61

51

38

30

23

5

195

162

121

97

77

60

48

38

31

100

120

160

200

250

300

400

500

600

Number of FLYWHEELS

Power

1

75%

54

45

33

25

17

11

5

-

-

2

106

88

65

52

41

34

24

16

10

3

157

131

98

78

62

51

38

30

23

4

208

173

129

103

82

68

51

40

33

5 Number of FLYWHEELS

Power

1

50%

260

217

162

129

103

86

64

51

42

100

120

160

200

250

300

400

500

600

82

68

51

40

32

25

11

5

4

2

159

132

99

79

63

52

39

30

23

3

237

197

147

118

94

78

58

46

38

4

313

260

195

156

124

103

77

61

51

5

391

326

244

195

156

129

97

77

64

100

120

160

200

250

300

400

500

600

39

135

101

80

64

53

39

26

23

2

313

260

195

156

124

103

77

61

50

3

465

387

290

232

185

154

115

92

76

4

614

511

383

306

245

204

152

122

101

5

767

639

479

383

306

255

191

152

126

Number of FLYWHEELS

Power

1

25%

All runtimes refer to UPS with 0.9pf and 94% efficiency for 100%, 75% and 50% load, and 92% efficiency for 25% load. With no battery connected.

www.riello-ups.com

121


Power solutions Power Box Container solutions

Highlights Eco-compatible UPS Very high efficiency, providing energy savings and reducing operating costs.

Compact and Efficient The use of flywheels in place of conventional batteries allows for a footprint reduction of 50-75%.

Reliable and resilient modules High reliability is synonymous with UPS with transformers such as the Master HP. Scalable and modular architecture (N+1) of up to 8 UPS arranged in parallel to ensure maximum reliability.

Reduced running costs Reduced footprint, fast ROI and high operating efficiency with very low running costs.

Easy maintenance A simple annual inspection accompanied by a minimum amount of preventative maintenance is all that is required to ensure optimum operation.

122

The PowerBoxes provide a continuous quality power supply wherever and whenever it is needed. Each PowerBox can be configured based on individual project specifications. PowerBox is a solution in a fully equipped container that can be sent, installed and deployed in the space of a few hours. Each PowerBox contains all of the necessary switches and protective devices to deliver uninterruptible power from a combination of apparatus that includes: a Riello UPS, a flywheel energy storage system, and a diesel generator. Master HP is one of the most flexible and efficient UPS on the market. In the event that the mains power supply fails, a conventional UPS makes use of a battery set. In this case

clean energy is provided from a flywheel. The uninterruptible power supplies available can be configured in modular blocks from 200 kVA to 600 KVA, which can be set up in parallel to reach up to 4 MW of clean energy. The backup time can be extended via the use of flywheels set up in parallel or by traditional battery sets (Battery Hardening). This architecture is useful for using flywheels as the first source of backup power, thus protecting batteries from unnecessary discharges. Flywheels also provide all the advantages of an auto transfer switch, as well as the advantages of practically instantaneous recharge compared with the hours or days required to recharge conventional batteries.


Power Solution in Container

Master HP UPS

Flywheel and/ or Battery Box

Auto Transfer Switch

Diesel generator with built in tank

Easy to move and transport, connect and power, the Riello PowerBox is a highly efficient solution ideal for: • Modular data centres requiring modular uninterruptible power supplies • Data centres in urban areas requiring additional power • Public events requiring extra power for short periods • Remote and military installations.

PowerBox is available in different combinations. Below are two examples of installations in 20 and 40-foot containers, with Riello UPS, a flywheel and a diesel generator.

MODELS

PowerBox 60,200,300

PowerBox 121.500.600

Features

UPS + Flywheel + Generator

UPS + Flywheel + Generator

UPS power

1 x 200 kVA

1 x 500 kVA

Flywheel

1 x 300 kW

1 x 600 kW

275 kVA

700 kVA

Input

400 A

1,000 A

UPS input

317 A

794 A

Batteries^

Optional Battery Boxes

Optional Battery Boxes

UPS output

289 A

724 A

Dimensions

[WxDxH] 605 x 243 x 253

[WxDxH] 1210 x 243 x 253

20 feet

40 feet

8,000 kg

15,000 kg

Diesel generator*

Container Weight

Note: * 8 hour fuel tank, optional 20 hour tank, ^ from 5-10 minutes or more to provide extra resilience

www.riello-ups.com

123


Power solutions Central Supply Systems 1:1 3:1 6-15 kVA 3:3 10-100 kVA EN50171

COMPLIANT

Highlights Compliant with standard EN 50171 Ideal for emergency lighting and alarm systems.

Dual Input Simplicity and safety for the periodical system operation check.

Protection against battery inversion Protection for emergency services and safety for operators.

High recharge current Reduced recharge times.

Continuous overload of 120%

The CSS (Central Supply System) range by Riello UPS is designed in compliance with standard EN 50171 and is therefore the ideal solution for installation in buildings subject to fire safety regulations and in particular for the power supply of emergency lighting systems. In addition the CSS range by Riello UPS is also suitable for supplying power to other emergency systems such as automatic fire extinguishing systems, alarm systems and emergency detection systems, smoke extraction equipment and carbon monoxide detection devices as well as dedicated security systems in sensitive areas. The use of centralised supply systems (CSS) ensures a significant reduction in system set-up and maintenance costs as well as making periodical checks simpler and faster to perform.

Large power reserve.

Casing compliant with standard EN 60598-1 High mechanical protection.

Batteries with 10 year life Long battery life.

124

DUAL INPUT The Riello UPS CSS range is equipped with DUAL INPUT as standard on all models. This important feature allows the mandatory scheduled checks on system operation and autonomy to be carried out with extreme

ease and in complete safety by simply operating an input switch. This switch interrupts the power supply to the machine without interrupting the bypass line, which is able to support the load in the event of test failure.

HIGH RECHARGE CURRENT AND BATTERY CARE SYSTEM Proper battery care is critical to ensuring correct CSS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities designed to obtain the best performance, extend operating life and satisfy the recharge times imposed by the standard. The Riello UPS CSS range is designed in compliance with standard EN 50171 and ensures high current levels are available for the batteries, allowing recharge of up to 80% of full autonomy within 12 hours. Riello UPS CSS are suitable for use with hermetically sealed lead-acid (VRLA), AGM and GEL batteries and Open Vent and Nickel Cadmium batteries. Different charging


methods are available depending on the battery type. The recharge voltage compensation function based on temperature prevents excessive battery charges and overheating. The deep discharge protection prevents reduced battery performance and battery damage.

HIGH OVERLOAD CAPACITY As required by standard EN 50171, the Riello UPS CSS range is designed and sized to support continuous overloads (with no time limits) of up to 120% of the machine's nominal power rating.

GENERAL FEATURES In addition to the features mentioned here, the Riello UPS CSS range has all the features of reliability and flexibility common to the UPS range it derives from, as well as offering compatibility with the main options and accessories.

MODELS The Riello UPS CSS range is based on both single-phase and three-phase models divided into two product families, 1h and 3h, optimised to offer maximum runtimes of 1

hour and 3 hours respectively at nominal load in accordance with the parameters set out in standard EN 50171. In particular the models in the 3h range feature transformer-based technology and provide maximum protection for the connected load. The models in the 3h range are based on transformer-less technology, therefore providing improved efficiency and reduced footprints.

PROTECTION AGAINST BATTERY INVERSION Mandatory in line with standard EN 50171, protection against battery inversion ensures the safety of those carrying out maintenance operations on the devices and at the same time prevents damage to the system in the event that the batteries are inadvertently connected with the wrong polarity.

OPERATING MODE Every Riello CSS model supports all the operating modes set out and described in standard EN50171, as below:

A Changeover mode The load is supplied via the CSS bypass line (always supplied output “AS”). In the event of power supply failure the internal automatic device (ATSD) transfers the load to the inverter. The battery provides power to the inverter, ensuring the required ASDT runtime.

B Mode without interruption The load is supplied constantly by the CSS inverter (always supplied output “AS”). In the event of power supply failure the battery provides power to the inverter, ensuring the required runtime with no interruptions at all.

C Changeover mode with additional control switching device for control switching of the load In addition to that described in points A and B, the equipment includes one or more switching devices (CSD), which rely on the availability of the normal power supply. On power supply failure the CSD device connects the load that up until that moment was not supplied (emergency ASDT only output “EO”). CSD

EOS optional accessory The EOS (Emergency Only Switch) accessory is required whenever one part of the load must always be supplied (always supplied output “AS”), and one part must be supplied only when mains power fails (emergency only

D Changeover mode with additional control switching device for partial switching of the load

ASDT

Differently to that described in point C, part of the load is supplied without interruption whilst the remaining part is only supplied upon power supply failure thanks to the CSD device (always supplied + emergency only output “AS+EO”).

CSD*

*Requires EOS optional accessory

output “EO”), in order to create the operating mode described in point D. By connecting several EOS accessories in a cascade configuration it is also possible to provide for the sequential delayed switching on of loads in order to reduce inrush switching on currents.

www.riello-ups.com

125


CSS 1h models

6

1 ph

10

1 ph

15

1 ph

10

3 ph

15

3 ph

20

3 ph

30

40

3 ph

3 ph

60

3 ph

80

100

3 ph

3 ph

INPUT Nominal voltage

220 - 230 - 240 Vac 1 ph 380 - 400 - 415 Vac 3 ph + N

380 - 400 - 415 Vac 3 ph + N

Nominal frequency

50/60 Hz

Frequency tolerance

40 - 72 Hz

BYPASS Nominal voltage

220 - 230 - 240 Vac 1 ph

380 - 400 - 415 Vac 3 ph + N

1

3+N

Number of phases Voltage tolerance

180 - 264 V (selectable)

Nominal frequency

50 or 60 Hz (selectable)

Frequency tolerance

±5 (selectable)

OUTPUT Nominal power (kVA) Active power (kW)

6

10

15

10

15

20

30

40

60

80

100

5,4

9

13,5

9

13,5

18

27

36

54

72

90

Power factor

0.9

Number of phases Nominal voltage

1

3+N

220 - 230 - 240 Vac 1 ph

380 - 400 - 415 Vac 3 ph + N

Static variation

± 1%

Dynamic variation

± 3%

Crest factor

3 : 1 Ipeak/Irms

Voltage distortion

≤ 1% with linear load / ≤ 3% with non-linear load

Frequency

50/60 Hz

Frequency stability during battery operation

0.05%

Overload

120% continuous @ Pf 0.9

BATTERIES Type

VRLA AGM/GEL 10 years (external)

Recharge time

80% of full autonomy in 12 hours

Typical recharge current

0.2 x C10

Temperature compensation

-0.5 V/°C

INFO FOR INSTALLATION Weight without batteries (kg) Dimensions (WxDxH) (mm)

105

110

120

Operating temperature

Standards

Moving the CSS

126

145

190

200

220

500 x 850 x 1600

380 750 x 855 x 1900

0°C / +40°C 90% non-condensing

Colour

Smart Active efficiency

135

3 slots for communications interface / USB / RS232

Relative humidity

IP rating

120

440 x 850 x 1320

Communications

Noise level at 1 m

110

Dark grey RAL 7016 < 52 dBA

< 48 dBA

< 56 dBA

< 58 dBA < 70 dBA

IP20 up to 99% EN 50171 - European Directives: L V 2006/95/CE low voltage Directive EMC 2004/108/CE electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111 castors (6 - 80 kVA) / transpallet (100 kVA)


CSS 3h models

6

1 ph

10

1 ph

15

1 ph

10

3 ph

15

3 ph

20

3 ph

30

40

3 ph

3 ph

60

3 ph

80

100

3 ph

3 ph

INPUT Nominal voltage

380 - 400 - 415 Vac three-phase

Nominal frequency

50/60 Hz

Frequency tolerance

40 - 72 Hz

BYPASS Nominal voltage

220 - 230 - 240 Vac 1 ph

380 - 400 - 415 Vac 3 ph + N

1

3

Number of phases Voltage tolerance

± 5% ÷ ± 25%

Nominal frequency

50 or 60 Hz (selectable)

Frequency tolerance

± 1% ÷ ± 6%

OUTPUT Nominal power (kVA) Active power (kW)

6

10

15

10

15

20

30

40

60

80

100

5,4

9

13,5

9

13,5

18

27

36

54

72

90

600

610

Power factor

0.9

Number of phases Nominal voltage

1

3+N

220 - 230 - 240 Vac 1 ph

380 - 400 - 415 Vac 3 ph + N

Static variation

± 1%

Dynamic variation

± 3%

Crest factor

3 : 1 Ipeak/Irms

Voltage distortion

≤ 1% with linear load / ≤ 3% with non-linear load

Frequency

50/60 Hz

Frequency stability during battery operation

0.05%

Overload

120% continuous @ Pf 0.9

BATTERIES Type

VRLA AGM/GEL; NiCd; Li-ion 10 years (external)

Recharge time

80% of full autonomy in 12 hours

Typical recharge current

0.2 x C10

Temperature compensation

-0.5 V/°C

INFO FOR INSTALLATION Weight without batteries (kg)

200

220

230

241

256

315

335

460

540

Dimensions (WxDxH) (mm)

555 x 740 x 1400

Communications

2 slots for communications interface / 2 RS232 / dry contacts

Operating temperature

90% non-condensing

Colour

IP rating Smart Active efficiency

Standards

Moving the CSS

800 x 800 x 1900

0°C / +40°C

Relative humidity

Noise level at 1 m

800 x 740 x 1400

Dark grey RAL 7016 60 dBA

62 dBA

65 dBA

68 dBA

IP20 up to 98% EN 50171 - European Directives: L V 2006/95/CE low voltage Directive EMC 2004/108/CE electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111 transpallet

www.riello-ups.com

127


Software and accessories PowerShield3 SHUTDOWN Software

PowerShield3 is available for download at www.riello-ups.com

Highlights GRAPHIC MONITORING OF UPS AND ENVIRONMENTAL SENSOR STATUS

PowerShield3 is a simple but powerful UPS management tool. A graphic version is available for all operating systems.

DETAILED DISPLAY OF ALL UPS AND ENVIRONMENTAL SENSOR PARAMETERS

PowerShield3 provides all the information required for first level diagnostics.

EVENTS LOG AND GRAPHIC DISPLAY OF MAIN PARAMETERS

All changes in UPS operating states are logged, as well as the main physical values and parameters. These constantly recorded values are displayed in graphic format.

UPS CONTROL PROGRAMMING

This allows you to automate all the actions normally carried out by the user: turning the server on and off, UPS battery test, etc.

GRAPHIC MONITORING OF UPS STATUS VERSION FOR MAC OS X

PowerShield3 software is the only control and shutdown software able to run on a Macintosh system with a client-server cross-platform architecture. It allows integration in TCP/IP networks with Windows, Novell, and the most widely used UNIX operating systems. It supports the NetMan series of network agents for UPS management via network. Multi-lingual support.

BLOCK DIAGRAM OF OPERATION

A display of UPS operation in the form of a block diagram makes the analysis of UPS operating states more intuitive.

NOTIFICATION OF ALARMS VIA E-MAIL, SMS, FAX AND VOICE MESSAGE

PowerShield3 can be configured to automatically forward alarm warning messages via e-mail, SMS, fax and voice message.

PowerShield provides efficient, userfriendly UPS management, displaying all major operational information such as input voltage, applied load and battery charge. The software also provides detailed information on fault conditions and UPS operating states. Developed with a client/ server architecture, it is the ideal tool for managing multi-platform network systems. 3

128

Features • PowerShield3 free version: supports a single UPS for the operating systems highlighted in green. • PowerShield3 full version: supports up to maximum of 32 UPS for all operating systems. • With sequential and priority-based shutdown, PowerShield3 provides unattended shut-down of all networked PCs, saving any active work on the most widely used applications. Users can define the shutdown priorities for the various computers in the network and can also customise the procedure. • With multi-platform compatibility, PowerShield3 uses the TCP/IP communications protocol to achieve standardised management and monitoring across the widest possible range of platforms. This makes it possible to monitor computers with different operating systems from a single console, for example monitoring a UNIX server from a PC running Windows and also connecting to UPS located in different geographical areas using dedicated networks (intranets) or the Internet. • With event scheduling, PowerShield3 users can program their own shutdown procedures, detailing power-off and power-up scenarios to increase system security and save energy. • With messages management, PowerShield3 keeps users constantly informed about the status of UPS and environmental sensors, either locally or via network messages.

A list can also be defined of users who should receive e-mails, faxes, voice messages and SMS messages when faults or sudden mains power supply failures occur. • Integrated SNMP agent: PowerShield3 features an integrated SNMP agent for UPS management which can send all the information required and generate traps using the RFC1628 standard, and environmental sensors. • Secure, easy to use and connect; communication is now password protected to ensure UPS system security. Using the new discovery/ browsing function, all UPS connected to a protected computer and/or LAN can be displayed in a list format for monitoring. In the absence of a LAN connection, support is provided for modem-based communication.

Supported operating systems • Windows 2000, 2003 Server, XP, Vista, 2008 Server, 7, 8, on X86, X86_64 and IA64 processors • Linux on X86, X86_64 and IA64 processors • Novell Netware 3.x, 4.x, 5.x, 6 • Mac OS X • VMWare ESX, VSPHERE. • The most common UNIX operating systems such as: IBM AIX, HP, SUN Solaris INTEL and SPARC, SCO Unixware and Open Server, Silicon Graphics IRIX, Compaq Tru64 UNIX and DEC UNIX, Open BSD UNIX and FreeBSD UNIX, NCR UNIX • HP OPEN VMS.


PowerNetGuard Inventory manager software

PowerNetGuard is available for download at www.riello-ups.com

Highlights GRAPHIC MONITORING OF UPS AND ENVIRONMENTAL SENSOR STATUS

PowerNetGuard is a simple but powerful UPS management and display tool. A graphic version is available for all operating systems.

DETAILED DISPLAY OF ALL UPS AND ENVIRONMENTAL SENSOR PARAMETERS

PowerNetGuard provides all the information required for first level diagnostics.

EVENTS LOG AND GRAPHIC DISPLAY OF MAIN PARAMETERS

All changes in UPS operating states are logged, as well as the main physical values and parameters. These constantly recorded values are displayed in graphic format.

CENTRALISED MANAGEMENT

PowerNetGuard is the ideal solution for managing all UPS in an infrastructure using a single application. With this one application you can monitor and manage all your UPS, ensuring prompt warnings in the event of faults or malfunctions.

PowerNetGuard software centralises UPS management using network interface (SNMP) communications. It is ideal for Data Centre EDP managers and medium to large-sized networks. Using the RFC1628 Management Information Base (MIB), it ensures standardised management for all UPS compliant with this worldwide standard.

Features • Centralised control of remote UPS via Ethernet with SNMP protocol • Multi-level display of geographical areas, building plans, maps, etc.

• Multi-user access with various security levels • Compatible with NetMan and RFC1628 standard SNMP agents • Creation of graphs of input and output values and data back-up to file • Alarm notifications via e-mail and SMS • Integrated Wap Server for alarm display • For Windows operating systems (2008 Server, Vista, 2003 and XP), Linux, Solaris 8, 9 and 10, and Silicon Graphics IRIX

SUPPORT FOR THIRD PARTY UPS

PowerNetGuard also allows you to manage UPS made by other manufacturers via SNMP using their own network boards. This allows you to centralise the management of the UPS fleet into a single system without the need for many different applications, simplifying management and use.

www.riello-ups.com

129


NetMan 101/102 Plus Box - Ethernet - SNMP The NetMan plus network agent allows UPS management across a LAN 10/100 Mb direct connection using any of the main network communication protocols (TCP/IP, HTTP and SNMP). It was developed to integrate UPS into medium-sized and large networks, to provide a high level of reliability in communication between the UPS and associated management systems.

Features • Compatible with 10/100 Mbps Ethernet • Compatible with PowerShield3 and TeleNetGuard • SNMP with RFC1628 for PowerNetGuard and NMS connection • SNMP with RFC3433 for managing environmental sensors • HTTP for UPS control via web browser • SMTP for alarm notifications and UPS status updates via email • Serial port for UPS control

• Modem management for TeleNetGuard and PowerShield3 • Events log management • Wake-on-LAN management for starting computers via TCP/IP network • Other standards: DHCP, DNS, RARP, FTP, NTP, ICMP, IGMP • Configurable via Telnet multi-sessions or serial terminal with data import/export • Firmware upgradeable via serial port and TFTP server.

NetMan 202 Plus Card - Ethernet - SNMP The NetMan 202 plus network agent allows UPS directly connected over LAN 10/100 Mb connections to be managed using the main network communication protocols (TCP/IP, HTTP and SNMP). It is the ideal solution for the integration of UPS over Ethernet networks with Modbus/TCP protocols. It was developed to integrate UPS into medium-sized and large networks, to provide a high level of reliability in communication between the UPS and associated management systems.

Features • 32bit RISC processor • Compatible with 10/100 Mbps Ethernet and IPv4/6 networks • Compatible with PowerShield3 and TeleNetGuard • SNMP v1 and v3 with RFC1628 for PowerNetGuard and NMS connection • SNMP v1 and v3 with RFC3433 for the management of environmental sensors • HTTP for UPS control via web browser • SMTP for alarm notifications and UPS status updates via email • Modbus/TCP • Maximum expandability • USB host for Pendrive USB connection • Events log and data management • Wake-on-LAN management for starting computers via TCP/IP network • Other standards: DHCP, DNS, RARP, FTP, NTP, ICMP, IGMP • Management of environmental sensors • Configurable via Telnet or SSH sessions, and serial terminal with data export/import • Firmware upgradeable via USB port, FTP and http. 130

Environmental sensors For netman 101, 102 and 202 plus The NetMan plus environmental sensors are able monitor and record environmental conditions as well as activities in protected areas and the area where the UPS is installed. The environmental sensors allow management and control to be extended to cover the area around the UPS, monitoring the temperature and humidity and driving cooling fans or locks. Values are provided via Internet, SNMP and via PowerShield3 software. PowerShield3 can be used to manage sensor operating states in order to send messages. Refer to PowerShield3 software documentation for further information. NetMan plus can manage up to 6 separate sensors. Environmental sensors are quick to

UPS operating environment control system

UPS Riello

install thanks to their small footprint, and they do not require a separate external power supply. Thanks to the self-learning sensors, configuration is also rapid and intuitive.

The following sensors are available: - -55 +125 °C Temperature Sensor - -55 +125 °C Temperature and 0-100% humidity Sensor - -55 +125 °C Temperature and I/O digital 0-12 Vdc In, 1A max Out at 48 Vdc Sensor.

Temperature sensor Conditioner

Netman Temperature sensor

+ digital control

Smoke detector


MultiCOM 301/302 Box/CARD - Modbus/Jbus interface The MultiCOM 301/302 protocol converter allows UPS monitoring using the MODBUS/ JBUS protocol over RS232 or RS485 serial lines. In addition, it also manages a second independent RS232 serial line that can be used to connect to other devices such as the Netman 101 or a PC running PowerShield3 software.

Features • Port configuration for MODBUS/JBUS as RS232 or RS485 • Management of two independent serial lines • Suitable for integration with the main BMS management programs.

MultiCOM 351/352 Box/CARD - Interface duplexer The MultiCOM 351/352 serial duplicator is an accessory that allows two devices to be connected to a single communication serial port on the UPS. It can be used anywhere where several serial connections are required for multiple polling of the UPS. It is ideal for LAN networks with firewalls, where a high level of security is required, or for the management of separate LAN networks supplied by a single UPS.

Features • Cascading configuration giving a maximum of 4 serial communication ports • LED communication flow indicator • Firmware upgradeable via serial port.

MultiCOM 372 Card - RS232 interface The MultiCOM 372 allows an additional communication port to be added to the UPS to control and monitor the UPS via the RS232 serial line. The board is supplied with an ESD (UPS Emergency Shutdown) input and an RSD (Remote Shutdown) input, both available on a removable terminal board and directly connectible to emergency buttons or other buttons.

Features • Management of ESD input and UPS Shutdown • Ability to supply devices at 12 V 80 mA max. For compatibility, refer to the Table on page 16

www.riello-ups.com

131


MultiCOM 382 Card - Relay I/O interface The MultiCOM 382 provides a set of relay contacts for managing UPS alarm notifications and operating states. The board has two removable terminal boards. One of these terminal boards includes the ESD (UPS Emergency Shut Down) and RSD (Remote Shut Down) signals. The board also provides the possibility of associating Battery Working, Bypass, Alarm

and Battery Low warnings with potential free changeover or normally open contacts.

Features • Max. current 3A at 250Vac • Signal-contact customisation. For compatibility, refer to the Table on page 16

MultiCOM 401 Box - Profibus DP interface The MultiCOM 401 is an accessory that allows UPS to be connected to a Profibus DP network. The device integrates UPS management and monitoring in a control system based on a field bus that is among the most widely used in the industrial sector for communication between control / automation systems and distributed I/O.

Features • Profibus DP-V1 protocol • Configurable addresses from 0 to 99 • Data format: Profidrive V2 PP05 • Communication speed configurable from 9.6 kBit/s to 12 MBit/s • LED displaying the communication flow.

Multi I/O Box - Relay I/O Card & Modbus/Jbus interface The Multi I/O is a device that integrates UPS into a control system using fully configurable input and output relay signals. It can be used to connect two devices to a single UPS serial communication port. It can be used anywhere where several serial connections are required for multiple polling of the UPS. It can also communicate on RS485 lines using the MODBUS/JBUS protocol.

132

Features • 8 analogue/digital inputs • 8 relay outputs (3A at 250Vac) that can be configured using UPS and input operating states • Can communicate with UPS via RS232 • It can control two independent RS232/ RS485 serial lines to monitor the UPS and its operating states using the MODBUS/ JBUS protocol • Firmware upgradeable via serial port.


I/O EXPANSION BOARD The I/O expansion board for the Master range is equipped with: • 6 outputs with NC/NO potential-free contacts (250 V/5 A), electrically isolated from each other and from other circuits • 2 self-powered inputs.

Each output or input can be configured with different meanings, using the associated menu. For compatibility, refer to the Table on page 16

Kit for AS400 and i-Series Communications kit The IBM AS/400 system has a single-level memory management feature that makes it almost compulsory for the system to be connected to a UPS. This is because a momentary loss of power with consequent anomalous shutdown can lead to lengthy or even extremely lengthy reboot periods.

Also, even simple interference in the power supply can lead to hardware damage. The AS/400 interface kit allows the OS/400 operating system to initiate an orderly system shutdown on mains failure.

Features • Compatible with all AS/400 and i-Series systems • Supports all UPS in the Riello UPS range.

Modem GSM modem The GSM modem is able to send SMS messages detailing operating states and alarm warnings for devices monitored by PowerShield3 control software and PowerNetGuard supervision software.

www.riello-ups.com

133


RTG 100 GPRS MODEM The GPRS RTG 100 terminal is able to manage UPS connected directly to the GSM mobile telephone network. It was developed to integrate UPS into the TeleNetGuard remote control system for complete control of UPS and diagnostics in the event of failure without the need for landline connections. The RTG 100 is able to communicate constantly with UPS to provide the TeleNetguard remote control system

Multi Panel Remote Display interface The Multi Panel is a remote monitoring device that can provide a detailed UPS status overview in real time. This device is able to display mains power, output and battery readings as well as UPS operating states. The high visibility graphic display supports English, Italian, German, French, Spanish, Russian, Chinese and many other languages. It has 3 independent serial ports, one of which allows for UPS monitoring via the MODBUS/JBUS protocol (on either an RS485 or RS232 serial line). The other independent serial lines can be used to connect devices such as the Netman 101 Plus or a PC running PowerShield3 software.

Features • High visibility LCD with graphic functions • Management of three independent serial lines • Port configuration for MODBUS/JBUS as RS232 or RS485 • Suitable for integration with the main BMS management programs • Firmware upgradeable via serial port.

134

or PowerShield3 software with a valid alternative to connection systems employing communication cables.

Features • Ability to send SMS messages detailing UPS operating states and alarms • Compatible with PowerShield3 and TeleNetGuard • Events log management • Firmware upgradeable via GSM.


Multi Pass 10, 16, and 16-R MAINTENANCE BYPASS The Multi Pass manual bypass cuts out UPS in the event of malfunction or breakage. Multi Pass ensures that the connected consumers are automatically switched to mains power if a UPS is switched off or goes into blocked status. Multi Pass is available for rack or wall installations (box).

Features • 16 A rack version • 10 A and 16 A wall version • Standard back-feed protection • Automatic switching during mains failure • Mains power present LED indicator • Available with different socket standards (IEC, British socket, terminal boards).

MBB32A MAINTENANCE BYPASS Available in a 32 A single-phase configuration, enables UPS servicing up to 6kVA in a quick and safe manner ensuring power continuity. Equipped with a metal bracket for wall mounting.

MBB100A MAINTENANCE BYPASS Available in a single configuration that allows for manual bypass operations on any singlephase UPS from 10-20 kVA and three-phase UPS from 10-40 kVA. The device is equipped with three disconnect switches as shown in the attached diagram to allow for the complete isolation of the UPS in the event of maintenance or removal, whilst guaranteeing power supply continuity to the consumers. The device is equipped with a manual

bypass closure warning micro-switch to be connected to the dedicated input on the UPS in order to prevent simultaneous supply from the manual bypass and inverter. RIELLO UPS offers a wide range of external bypasses and static switches for UPS up to 800 kVA, and for parallel systems up to 6.4 MVA.

www.riello-ups.com

135


Connectivity Index of configurations Connecting a UPS to other devices, sensors, computers and other specific devices, means on the one hand allowing the user to monitor UPS operating parameters and prevent critical situations, and on the

other hand provides the UPS with input parameters from the working environment. By processing these parameters the UPS is able to activate/deactivate itself, communicate its status and much more.

• Point to point connections • Multipoint connection • Connection for UPS in parallel setup • Connection with several systems in parallel setup and STS

This brief overview summarises some of the basic connectivity configurations, grouped according to the end purpose and situation surrounding each case.

• Field bus connections • Bus connections over Ethernet • Field bus connections • Serial bus connections

POINT TO POINT CONNECTIONS Controlling the UPS from 1 workstation 1 2

UPS Riello

UPS connected to load Local computer with PowerShield3 version FREE USB or RS232

1

2

Controlling the UPS from different workstations

4

1 2

UPS Riello 3 1

UPS connected to load Local computer with PowerShield3 version FREE

3

Local computer with PowerShield3 software version FULL

4

MultiCOM 372 board RS232

2

USB or RS232

UPS control from several workstations, using 2 serial ports

4

1 2

UPS Riello 3 1

UPS connected to load Local computer with PowerShield3 version FREE

3

Local computer with PowerShield3 version FREE

4

MultiCOM 352 board RS232

2

136


Distributed connection (multipoint) Connection with more than 1 UPS. The FULL version of PowerShield3 software is required as well as a NetMan 101/102 communication board on each UPS.

2

UPS Riello 1

3

5

2

UPS Riello 1

1 2 3 4 5 6 7

UPS connected to load

8

UPS connected to load

4

NetMan 102 board Firewall Switch Remote computer connected via web Local computer Local computer that controls the UPS (8) via USB or RS232, and UPS (1) via LAN and Ethernet USB or RS232 Ethernet World Wide Web

6

UPS Riello 2

1

UPS Riello 8

7

CONNECTION FOR UPS IN PARALLEL SETUP The FULL version of PowerShield3 software should be used for managing setups with several UPS installed in parallel, and each UPS must have a NetMan 102 plus (or box 101 plus) board installed.

1

2

5

3 1

1

UPS in parallel setup connected to the load

2 3 4 5 6

NetMan 102 board Firewall Switch Remote computer connected via web Local computer Ethernet World Wide Web

2

Parallel setup bus 4

1

2

6

www.riello-ups.com

137


CONNECTION WITH SEVERAL SYSTEMS IN PARALLEL AND STS The FULL version of PowerShield3 software should be used for managing setups with several UPS installed in parallel, and each UPS must have a NetMan 102 plus (or box 101 plus) board installed.

8 1

2 5

4

2

2

7

1

2

1

UPS arranged in parallel connected to an STS channel

2 3

NetMan 102 board

4 5 6 7 8

Switch

9

3

UPS arranged in parallel connected to an STS channel Firewall STS connected to load UGS Local computer with PowerShield3 software version FULL Remote computer connected via web, running PowerShield3 software version FULL UGS management of parallel setup

2

Parallel setup bus Ethernet 6

World Wide Web

6

Parallel setup bus Power connection

9

2 3

FIELD BUS CONNECTION OVER ETHERNET For UPS management in industrial or civil environments requiring Modbus protocol communication over Ethernet.

1

1 2 3 4

2

UPS connected to load NetMan 202 board SCADA management system Switch Ethernet Modbus / TCP over Ethernet

3 4 1

2

138


MODBUS SERIAL FIELD BUS CONNECTION For UPS management in industrial or civil environments requiring Modbus protocol communication over RS 485 line.

1

1 2 3

2

UPS connected to load NetMan 302 board SCADA management system Ethernet Modbus RS485

1 2

3

1

1 2

PROFIBUS DP SERIAL FIELD BUS CONNECTION For UPS management in industrial or civil environments requiring communication via Profibus DP protocol.

1

1 2 3

2

UPS connected to load NetMan 401 board SCADA management system Ethernet Profibus DP

1 2

3

1

1 2

www.riello-ups.com

139


Services Pre-sales consultancy

RENTING

tec@riello-ups.com

The TEC team

Technical seminars

Why rent?

Consultancy on standards

The TEC team can provide technical assistance concerning the choice, sizing and installation of our products and solutions.

Design support

Our TEC (Technical Energy Consultant) experts have been working in the power sector for years, and come from backgrounds with technical experience in industry and power plants.

Regulatory standard consultancy concerning: • Products and portfolio solutions • Batteries, flywheels, super capacitors • Installation and configuration • Applications (emergency lighting, electro-medical, data centres, railways etc.)

Work tools Training and information

• • • • • •

UPS sizing Official technical guides Installation requirements TEC newsletters Technical specifications Online tools (TEC area, UPS configurator, runtime calculation, etc.)

Seminars can be requested by engineering firms or end customers directly and can also be proposed by TEC for sector associations and colleagues.

Help Desk

The TEC service is available by phone, fax or e-mail to answer your requests immediately.

Witness test

The witness test service is provided for checking solutions before transport to the installation site.

Advantages

• • • • •

Immediate UPS availability. Maintenance and assistance for the entire duration of the rental lease. Variable and flexible rental contracts: from 36 to 60 months. Increased reliability thanks to the presence of constantly updated UPS. Fully comprehensive insurance.

Guaranteed services

• • • • • •

140

Renting a UPS system from Riello is an ideal way to protect your investment from the risks of technological obsolescence and the limitations of ownership Renting does not require any minimum duration obligations and the fees are considered as operating costs and are therefore tax deductible. By renting a UPS, the customer enjoys the benefits of using the latest technologies without the disadvantages of ownership.

Dedicated freephone number. Dedicated e-mail address. Guide for choosing a UPS. Priority intervention thanks to the extensive network of Riello Service Centres. Remote monitoring. Removal of old UPS.


Telenetguard Remote monitoring 24/7

Technical assistance service@riello-ups.com

The Service team

Our technical assistance facility uses highly trained engineers to provide a reliable and competent technical support and efficient after-sales service.

The services

Service can provide customers with: • a dedicated call-centre for direct contact with the Service organisation. Service personnel are always available and ready to provide advice and assistance regarding UPS installation and maintenance. • The new free swap assistance service • an on-site support service for larger UPS that cannot be transported, whether or not they are covered by the warranty. A fast repair on site is guaranteed through the use of state-of-the-art UPS technology, the professionalism of the Service personnel and Authorised Assistance Centres nationwide. Service guarantees that any spare parts used are original, tested and up-to-date.

Service can provide assistance during the installation and initial start-up of the products and train on-site personnel. Technical Service engineers can also Service 1st start verify site suitability, analyse and advise on rental solutions and disconnect and relocate equipment Maintenance contracts can be provided by Service to minimise the risks and costs connected with UPS breakdowns. Many types of maintenance contract are available, ranging from periodic inspections to comprehensive cover including labour and materials. Service regularly organises technical training courses for technicians at the Riello UPS training centre.

Remote monitoring

The remote monitoring service consists of a modem connection (GSM or dedicated telephone line) between your UPS and the Riello UPS Service Centre. In the event of failure your UPS will automatically call the Service Centre, which assesses the parameters sent and determines the priority of the call (distinguishing between a real failure and a simple alarm), and simultaneously transmits the alarm via fax, email or SMS to the customer.

Advantages

With TeleNETGuard, our Service Centres are able to intervene, already knowing the nature of the problem and thus shortening the time required to resolve the fault. The system also regularly transmits more than 500 UPS parameters to the Service Centre to help prevent any issues arising from the ageing of individual electronic components. With this service your UPS is monitored 24 hours a day, 7 days a week.

www.riello-ups.com

141


Operating Offices RPS S.p.A. LEGNAGO (VR) Registered office Viale Europa, 7 ZAI 37045 Legnago (Verona) Tel +39 0442 635811 Fax +39 0442 629098 www.riello-ups.com riello@riello-ups.com CORMANO (MI) Sales Office Via Somalia, 20 20032 Cormano (Milano) Tel +39 02 663271 Fax +39 02 66327351 ROME Sales Office Via Fosso della Magliana, 34/G 00148 Rome Tel +39 06 65192125 Fax +39 06 65192247

142

PRE-SALES SUPPORT (TEC) tec@riello-ups.com

AFTER-SALES SUPPORT (UPService) service@riello-ups.com


RIELLO UPS Ltd. (UK) Unit 50 Clywedog Road North Wrexham Industrial Estate Wrexham LL13 9XN Tel +44 (0)800 269 394 Fax +44 (0)1978 729 290

RIELLO ENERDATA s.l.u. (ESPAÑA) C/ Labradores, 13 Parque Empresarial Prado del Espino 28660 Boadilla del Monte - Madrid Tel +34 916 333 000 Fax +34 916 321 793

Riello PCI India Pvt. Ltd. (INDIA) Prime Group Building, 11/5B, Pusa Road, New Delhi - 110 005 Tel +91 11 41 888 999 (30 lines), Tel +91 11 41 888 888 Fax +91 11 2575 5815

CONSTANT POWER SERVICES Ltd. (UK) Unit 3 - Trust Industrial Estate, Wilbury Way - Hitchin, Herts, SG4 0UZ Tel +44 (0)1462 422 955 Fax +44 (0)1462 422 754

Delegacion Andalucia C/ Aviación 18, P. I. Calonge, Edificio Morera y Vallejo 1, 1ª Planta 41007 Sevilla Tel +34 955 040 044 Fax +34 955 040 041

Riello UPS (Asia) Co., Ltd. (PEOPLE’S REPUBLIC OF CHINA) 28F, 500, Fute Dong Er Road, Waigaoqiao Free Trade Zone, Pudong District - 200131 Shanghai Tel +86 21 50464748 Fax +86 21 50464648

RIELLO UPS GmbH (DEUTSCHLAND) Siemensstraße 12 21465 Reinbek bei Hamburg Tel +49 (0)40 727 57-06 Fax +49 (0)40 727 57-189 AROS GmbH (DEUTSCHLAND) Neufahrner Str. 12b D-85375 Neufahrn/Grüneck Tel +49 8165 / 9458-0 Fax +49 8165 / 9458-26

RIELLO TDL s.l. (ESPAÑA) C/Berguedà, 6 bis Pol. Ind. Plà de la Bruguera 08211 Castellar del Vallès, Barcelona Tel +34 (0)93 74 71 210 Fax +34 (0)93 71 46 562 RIELLO ONDULEURS S.a.r.l. (FRANCE) 2/4 Rue du Bois Chaland, ZAC du Bois Chaland – 91090 Lisses Tel +33 (0)1 60 875454 Fax +33 (0)1 60 875450 Agence Rhone Alpes - Sud 147 Avenue M. Mérieux, Parc de Sacuny, Park Avenir 1 69530 Brignais Tel +33 (0)4 72 177108 Fax +33 (0)4 78 351422

Sales office Beijing No.418, 4F, Block A, Gaode Platza, 10 Huayuan Dong Road, Haidian District - Beijing Tel +86 10 82038861 / 8862 Fax +86 10 82038863 Sales office Guangzhou Address Unit 1507 East Building, Dongshan Square, No. 65, Xianlie Zhong Road, Yuexiu District 510095, Guangzhou Tel +86 20 28848001 Fax +86 20 28848002 Singapore Rep. office (ASIA PACIFIC) 138, Robinson Road The corporate office #14-06 068906 Singapore Tel +65 6323 4131 Fax +65 6323 4212 MARM-UPS Pty Ltd. (AUSTRALIA) Unit 22/80 Box Road Taren Point NSW 2229 Tel +61 2 9531 1999 Fax +61 2 9531 1988 Unit 17/810-818 Princes Hwy Springvale VIC 3171 Tel +61 3 9574 6922 Fax +61 3 9574 6933 PO Box 2251 Yokine South WA 6060 Tel +61 1300 138,709

Follow us on Social Networks

www.riello-ups.com

143


Reliable power for a sustainable world



> 2013-2014

Product photos are purely indicative. Due to technical improvements and/or changes in regulatory standards, product specifications are subject to change without notice.

Follow us on Social Networks

CATGENX0Y13GREN

GENERAL CATALOGUE

RPS S.p.A. - Member of the Riello Elettronica Group Viale Europa, 7 - 37045 LEGNAGO (Verona) - Italy T +39 0442 635811 - F +39 0442 629098 www.riello-ups.com - riello@riello-ups.com

GENERAL CATALOGUE > 2013-2014


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.