Weschler Catalog

Page 1

TABLE OF CONTENTS CONTROLLERS 4 - 10 Temperature, Process, Proportional, PID, Fuzzy Logic, On/Off, Reverse Acting....

Panel, Switchboard, Bargraph, Power, Energy, Process, Multi-function, Counters.....

Transmitters, Isolators, Loop Splitters, Alarms, Programmable, Universal...

TRANSDUCERS / SENSORS 89 - 118

RECORDERS / DATA LOGGERS 119 - 126 Chart, Paper, Paperless, Process, Multi-channel, Temperature, Power.....

MISCELLANEOUS 127 - 138 Clocks, Timers, Switches, Displays, Enclosures, Power Supplies....

TECHNICAL REFERENCE 176 - 186 Application Notes, Tables, Formulas, Conversion Factors, Glossary...

Products by Manufacturer, Products by Type, General Information... Š 2009 Weschler Instruments

INDEX

INDEX 187 - 191

TECHNICAL REFERENCE

68 Years of Power and Process Measurements

Multimeters, Power Analyzers, Electrical Testers, Thermometers, Calibrators...

TEST EQUIPMENT

TEST EQUIPMENT 139 - 175

MISC.

Shunts, CTs, PTs, Temperature, Power, Pressure, Speed, Flow, Level, Humidity...

SIGNAL CONDITIONERS 80 - 88

TRANSDUCERS / RECORDERS / SENSORS DATA LOGGERS

Weschler Instruments distributes over 50 of the leading equipment brands. This catalog shows only a small portion of our total offering. Call, fax or email us for information on any models you don't see here. Our experienced sales team will be happy to assist you in selecting the best products for your application.

Switchboard, Edgewise, Panel, AC, DC, Power, Synchroscope, Meter Relays....

SIGNAL CONDITIONERS

ANALOG METERS 43 - 79

ANALOG METERS

This catalog also includes condensed information on the Weschler brand products manufactured at our Florida facility. Full specifications and application information for these products can be found on our website www.weschler.com. Also see our website for new products and reference information added since this catalog was printed.

DIGITAL METERS

DIGITAL METERS 11 - 42

CONTROLLERS

Welcome to the Weschler Instruments Product Catalog & Reference Guide. Here we present a selection of the more popular meters, sensors and test equipment available from our Measurement Specialists. This edition features many new products, as well as 'industry standard' models that have been used for many years.


Weschler Premo BarGraph Meter/Controller

The Premo Bargraph Controller is a full featured, high resolution meter for display and control of process parameters. A wide range of input modules measure electrical signals, sensors and transducers. Analog and digital outputs easily connect to remote indicators or a plant SCADA system. Up to 6 setpoints can be programmed to operate within the span of the selected input module. PID control is available from the first two setpoints.

PC

Specifications on next page.

ORDERING INFORMATION CONTINUED D

ORDERING INFORMATION

A

B

C D

A

B

C

D

E

F

G

H

I

Style C 4 1/2" Switchboard D 12" Edgewise Vertical G 6" Edgewise Vertical Bar Color R Red G Green T Tricolor Digital Display Color R Red G Green Input (partial list) DBQ DC, 20/50/100/200mV w/24V Excitation DCQ DC, 2/20/200mA w/24V Exc DGQ DC, 1A DDQ DC, 5A ABQ AC, 200mV/2V/20V, scaled RMS AAQ AC, 200/600V, scaled RMS AGQ AC, 200mV/2V/20V, True RMS AFQ AC, 200/600V, True RMS ACQ AC, 2/20/200mA, scaled RMS ADQ AC, 1 Amp, scaled RMS AEQ AC, 5 Amp, scaled RMS AHQ AC, 2/20/200mA, True RMS AJQ AC, 1A, True RMS AKQ AC, 5A, True RMS PDQ Process 2/5/10/20/200V/2mA/20mA/Custom TMP Thermocouple, J/K/R/S/T/B/N

PG

PD

To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: PCRGDCQ1A5CXXXX

PC

CONTROLLERS

Direct Measurement of: DC Current AC Current DC Voltage AC Voltage Frequency Power Process Loops Thermocouples RTDs Load Cells/ Strain Gauges LVDTs Pressure Speed Pickups/ RPM Resistance/Potentiometers Quadrature Event Counting

L

L

•Datalogging & PID control functions •Cross channel calculations with multi-channel input modules •Front panel & external dimming •Enhanced table calibration for tank level, square law & other non-linear measurements •Optional SD memory card for long term data logging •3 case styles

L

•101 segment red, green or tricolor bar •6 digit alpha-numeric readout •Rugged steel case, standard switchboard mounting •6 assignable relays with tracking, latching & manual reset functions •Single or dual analog retransmit •ASCII, Modbus Serial & Ethernet communications •Wide variety of input modules

NEW

J E F

G

H

I J

Input continued THP RTD, 100Ω Pt, 2/3/4-wire GHQ Direct Pressure, 30 psi differential/gage GKQ Direct Pressure, 100 psi differential/gage SBQ Pressure 5/10VDC Exc., 2/20 mV/V, 4/6-wire EAP Line Frequency, 50-500VAC FAP Universal Frequency / RPM / Up Down Counter CAP Quadrature Counter REP Resistance, 2/3/4-wire, 200/2k/20kΩ KAP Single Phase Power, 300V/1A from CT KBP Single Phase Power, 300V/5A from CT KCP DC Watts, 200V/50mV from shunt PAD Dual Process Loop, 4-20mA DCD Dual DC, 2mA DBD Dual DC, 2V TAD Dual Thermocouple, J/K/R/T FAD Dual Frequency FBD Dual Counter Power 1 85-265VAC/95-370VDC 2 15-48VAC/10-72VDC Retransmit (analog output) A Isolated 4-20mA or 0-20mA, scalable V Isolated 0-10VDC, scalable D Isolated Dual 0-10VDC, scalable X None Communications 2 Isolated ASCII Code RS-232 4 Isolated ASCII Code RS-485 5 Isolated ModBus Protocol RS-232 6 Isolated ModBus Protocol RS-485 8 Ethernet ACSII TCP/IP 9 Ethernet ModBus TCP/IP Relays (partial list) C Two 10A Form C D Two 10A Form C & Two 5A Form A H Six Form A X None Memory A 1M with Real time clock X Standard Options (2 digits) D Continuous external dimming W Spray tight front X None

4


Weschler Premo BarGraph Meter /Controller

Yokogawa Temperature Controllers

Continued from previous page

• On/Off, PID, Heat/Cool & Limit Control • Dynamic auto tune & "SUPER" overshoot suppression • Compact 1/16 DIN package • Large LED display • IP65 splash & dust-proof front panel • Optional analog retransmit of measured value UT130 • Timer function (UT150) • Optional heater burnout alarm & two alarm output relays • Optional 24V AC/DC power supply • Optional RS-485 MODBUS communication

SPECIFICATIONS CONTROLLERS

Digital Display Range:

-199999 to 999999

Decimal Point:

Five positions, front panel selectable

Update Rate:

3 to 10 times per second

Display Dimming:

8 level from front panel; continuous external option

A/D Converter:

Bipolar 17 bit (optional 23 bit)

Counter Functions:

Two built-in Up/Down counters

Data Logging:

Logging with date/time (Memory option A)

Trigger:

Time interval, setpoint, manual

Data storage:

Non-volatile EEPROM

Linearization:

4 selectable 32 point tables, cascadeable

Math Functions:

Sum, difference, ratio or the product of two inputs

Offset Functions:

Tare, compensation and calibration

Peak and Valley:

Min/Max storage with front panel recall

Digital Comm:

RS-232, RS-485, Ethernet

Setpoint Functions:

Hysteresis, on/off delays, one shot, pulse and repeat timers, latching, dual PID, setpoint tracking, logging trigger

Signal Processing: Timer: Totalalizer: Analog Output: Resolution: Compliance: Real Time Clock: Power: (DC to 400Hz) Operating Temperature: Software:

Averaging, smart filter, rounding, square root Time-up, time-down, or real-time clock modes Two, for Total and Batch Total Isolated 16-bit, accuracy 0.02% FS 0.4µA on current, 250µV on voltage 500Ω max. for current, 500Ω min. for voltage Optional, 15 yr Lithium battery backup 85-265VAC / 95-370VDC @ 5W max 15-48VAC / 10-72 VDC @ 5W max 0-50°C (32-122°F), <95% (non-condensing) at 40°C PC-based configuration utility

Style C Bar: Digits: Case: Size: Mounting: Style G Bar: Digits: Case: Size: Mounting: Style D Bar: Digits: Case: Size: Mounting:

5

7.25" length, 235° arc, ±60° viewing angle 0.43" (10.9mm) height Steel housing, molded front & rear bezel 4.43" square bezel, 4.75" behind panel Fits standard ANSI 4" switchboard cutout 10" length, ±60° viewing angle 0.31" (7.9mm) height Steel housing, molded rear bezel 1.7" x 6.04", 7" behind panel Fits standard ANSI 6" switchboard cutout 4" length, ±60° viewing angle 0.43" (10.9mm) height Steel housing, metal front, molded rear bezel 3.15" x 12.9", 7.8" behind panel Fits Bailey draft gauge cutout

L

SPECIFICATIONS Input: RTD: T/C (all models): T/C (UT15O models): DC In (UT15O models): Basic Accuracy: T/C: RTD: DC: Setpoints: Timer (UT15O models): Retransmit: Contact Input: Contact Output: Alarm: Display: Power: Approvals: Temperature: Dimensions:

3-wire Pt100 J, K, T, E, L, U R, S, B, N, platinel 0-100mV, 0-5V, 1-5V, 0-10V ±2°C ±1d ±1°C ±1d ±0.3% ±1d 1 on UT130, 2 on UT150 Up to 100 hours 4-20mA 2 points for SP select, run/stop or timer 2 for alarm, heater disconnect or timer 25 types UT130: single 0.7" 3-digit LED UT150: dual (red/green) 4-digit LED 100-240VAC, 8VA UL, CSA, CE 0-50°C operating 48x48x100mm

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number Example: UT130-RN/AL/RS A B C A

Model UT130 Temperature Controller UT150 Temperature & Voltage Controller UT150L Limit Controller B Control /RN Relay output /VN Pulse output3 /AN 4-20mA output (UT150 only)3 /RR Heat/cool relay outputs3 /VV Heat/cool pulse outputs3 /AA Heat/cool 4-20mA outputs (UT150 only)3 C Options /AL Alarm output (2 points) /V24 24V AC/DC power supply 3 /HBA Heater disconnect alarm 2 3 /RET Analog retransmit (UT150 only) /RS RS-485 Communications /EX Two contact input (UT150 only) 1 1 cannot be ordered with communications when heat/cool control specified 2 cannot be ordered with communcations 3 not available on UT150L


Extech PID Controller

Extech Temperature and Process Autotuning PID Controller

L

48VFL

Inputs Type K Type J Type B Type T Type E Type R, S Type N Type C Pt100 RTD (DIN) Pt100 RTD (JIS) Control/Alarm Relay DC Current Output Accuracy Sampling Time LED Status Control Modes

Front Panel Power Supply

-58 to 2498°F (-50 to 1370°C) -58 to 1832°F (-50 to 1000°C) 32 to 3272°F ( 0 to 1800°C) -454 to 752°F (-270 to 400°C) -58 to 1382°F (-50 to 750°C) 32 to 3182°F ( 0 to 1750°C) -58 to 2372°F (-50 to 1300°C) -58 to 3272°F (-50 to 1800°C) -328 to 1652°F (-200 to 850°C) -328 to 1202°F (-200 to 650°C) 5 Amp @ 110V, SPST (resistive load) 4-20mA (resistive); Impedance < 600 ohms T/C: ±1.8°F (1°C); RTD: ±0.36°F (0.2°C) 4 samples per second Alarm and Control output status Fuzzy Logic enhanced three-term PID with Auto Tune • Proportional Band 0 to 300.0% • Integral time 0 to 3600 seconds • Derivative time 0 to 900 seconds • Hysteresis 0.0 to 200.0 or 0.0 to 2000 • Cycle time 1 to 100 seconds Lexan, Drip/Dust proof, IP63 90 to 264 VAC; 50/60 Hz (< 5VA)

CONTROLLERS

SPECIFICATIONS

L

• Dual 4-digit LED displays for process & setpoint values • User-friendly menus and tactile keypad • Fuzzy Logic PID offers intuitive control • Manual mode overrides automatic control • One-touch Auto Tuning for quick setup and precise control • Single stage Ramp and Soak program with Ramp-to-Setpoint Limit • Soft Start feature for smooth process start-up • Accepts thermocouple and RTD inputs • Select input type from display menu – no hardware change • Two ‘Latching’ relays with 8 Alarm modes & advanced Timer modes

48VTR

• • • • •

1/16 DIN Size Dual Display of Process and Setpoint Value One-Touch Autotuning Single Stage Ramp Soak & Auto/Manual Control Modes Limit Alarm Relay with 8 Programmable Modes & Adjustable Deadband for Dual Control (Heat/Cool)

SPECIFICATIONS Temperature Inputs: RTD: DC Process Inputs: Accuracy: Control Action: Hysteresis: Ramp Rate: Limit Alarm Relay: Operating Temp: Panel Cutout: Power: Depth Behind Panel:

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 48VTR-1-3 A – B – C

A

Basic Unit 48VTR 1/16 DIN Ramp to Setpoint Controller Input 1 Thermocouple (J, K, T, B, E, R, S, N) R RTD (Pt100) A 4–20 mADC V 1–5 VDC Output 1 5A, 110 VAC Relay 2 Pulsed 24 VDC, Control Output 3 4–20 mADC, Control Output

B

C

ORDERING INFORMATION 48VFL11 48VFL13 96VFL11 96VFL13

1/16 DIN Temperature PID Controller with one relay output 1/16 DIN Temperature PID Controller with 4-20mA output 1/4 DIN Temperature PID Controller with two relay outputs 1/4 DIN Temperature PID Controller with 4-20mA output

J, K, T, B, E, R, S, N Pt 100 4–20 mA or 1–5 VDC 0.2% FS (indicating and setpoint) PID, ON/OFF 0.0 to 25.5% (for ON/OFF control) 0 to 100°C/min 5A at 110V 14 to 122°F (-10 to 50°C) 1/16 DIN: 1.77 x 1.77" (45 x 45 mm) 85 to 260 VAC 50/60 Hz 4" (102 mm) including screw terminals

ORDERING INFORMATION—ACCESSORIES 404216

1/16 DIN NEMA-4X Cover

6


Yokogawa Process Controllers UM330, UM350, UT320, and UT350 1/4 DIN, and 1/8 DIN Models Indicating Meter with Alarms (UM Series) Indicating Controller (UT Series) Retransmission Output and 15V DC Loop Power Supply are Provided as Standard • Universal Inputs • Communication Facility is Available Option

• • • •

UM330

The UM330 and UM350 Digital Indicator with Alarms are precision alarm instruments with universal input.

▲ UT320

All series models have exactly the same function and performance. Only the size and weights are different.

The UT320 and UT350 are highly accurate Digital Indicating Controllers, providing universal input/outputs. They have excellent monitoring operability with the Auto/Man switching key. In addition, heating/ cooling control, including PID control with auto-tuning, “Super” overshoot suppression function, and the “Super 2” hunting suppression are available as control functions.

UP350

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number Order Example: UT320-2-2 A – B – C

UP350 • • • •

Practical 2-Pattern Control Universal Input/Output Built–In Auto Tuning New Communication Method

The UP350 process controller is a precision controller, featuring two program profiles and universal input/output. Excellent control, auto-tuning, and PID control with a “Super”overshoot suppressor is available. Retransmission output and loop power supply for a sensor is also standard.

A

Basic Unit UM330 1/8 DIN Indicator with Alarms UM350 1/4 DIN Indicator with Alarms UT320 1/8 DIN Controller UT350 1/4 DIN Controller UT350L 1/4 DIN High Limit Controller UP350 1/4 DIN Program Controller Controls 0 General Purpose Model 2 Universal Heat/Cool (avail. UT only) 3 General Purpose w/ 24V DC Power Supply Options 0 None 1 RS-485 Port (all), plus 4th Alarm and Heater Break Alarm (UM only) 2 Heater Break Alarms (UT only) or 4th Alarm (UM only)

B

C

SPECIFICATIONS Inputs Thermocouple: RTD: Voltage: Input Accuracy: Retransmission Output:

Loop Pwr Supply: Event Output: Communication: Maximum Distance: Power:

K, J, T, B, S, R, N, E, L, U, W, Platinel 2, PR20-40, and W97Re3-W75Re25 JPt100, Pt100 DCV/mV ±0.1% (input period: 250 ms) Process variable and target setpoint; 4–20 mA output. NOTE: UM is 4–20 mA only. Sensor excitation (1.5 to 18.0V, approx. 21 mA) 21.6 to 28.0 VDC, 30 mA 2 PV event + 1-time event standard RS-485, 2- or 4-wire type 1200m, 31 units can be connected 100 to 240 VAC ±10%, 50/60 Hz

$ 410 $ 355 $ 495 N/C $ 100 $ 150 N/C $ 175 $ 65

ORDERING INFORMATION—ACCESSORIES 4859485C 4859X 4859BDC16 4859COV 4859COV8 4859LPS 4859100RES 4859250RES CTL-6P T9115YD T9115YE

RS-232 to RS-485 Port Powered Converter NEMA-3 Enclosure for Stand Alone Mount 16-Position Rotary BCD Switch NEMA-4 Rated Cover for 1/4 DIN NEMA-4 Rated Cover for 1/8 DIN 24 VDC, 100 mA Loop Power Supply—External .100Ω Precision Resistor 250Ω Precision Resistor 50 Amp CT for use with UT320/350 with Heater Break Alarm Terminal Cover for 1/4 DIN Green Series Terminal Cover for 1/8 DIN Green Series

6a


Fuji Temperature and Process Controllers • PID Plus Self Tuning and Fuzzy Control • Large LED Display

L

CONTROLLERS

• NEMA-4X/IP66 Waterproof Faceplate • Up to 16 Ramp/Soak Segments in Two 8Segment Patterns

PXR3

• Heating/Cooling Control • Timer Function • Dual Control Output Option • Digital Input Option • Analog Retransmission Option • Programmable Alarms Option • Heater Break Alarm Option • RS485 (Modbus™ Protocol) Option • Free Windows®- Based Software • Manufactured in an ISO 9001 Facility • 3-Year Warranty

L PXR5

L PXR9

L PXR4

SPECIFICATIONS Input Input signal:

Input filter: Input sampling cycle: Display Indication accuracy (at 23°C):

Control Function Control action: Control Outputs Relay contact:

SSR:

4 to 20 mA DC: Alarm (option) Alarm type:

Alarm ON-delay: Process alarm output:

Heater burnout option (not available on PXR3): Heater burnout alarm output:

7

TC: J, K, R, B, S, T, E, N, PL2. RTD: Pt100. Voltage, current. For 1 to 5V/4 to 20 mA DC, 0 to 5V/0 to 20 mA DC 0 to 900.0 sec set in 0.5 sec steps 0.5 sec TC: ±0.5% FS ± 1 digit ±1°C. TC R (0 to 500°C): ±1% FS ± 1 digit ±1°C. TC B (0 to 400°C): ±5% FS ± 1 digit ±1°C. RTD, Voltage, Current: ±0.5% FS ± 1 digit On/Off; PID control (with auto-tuning, selftuning); Fuzzy Control (with auto-tuning) PXR3 & Output 2: SPST contact, 220 VAC/30 VDC, 3A (resistive load). PXR4, 5, 9: SPDT, 220 VAC/30 VDC, 3A (resistive load) PXR3: 12 to 16 VDC PXR4, 5, 9: ON–17 to 25 VDC; OFF–0.5 VDC or less. Max. current: 20mA or less PXR3: Allowable load resistance 100 to 500Ω. PXR4, 5, 9: 600Ω or less Absolute alarm, deviation alarm, zone alarm with upper and lower limits for each; hold function available; alarm latch function provided 0 to 9999 sec in 1 sec steps Relay contact: SPST, 220 VAC/30 VDC, 1A (resistive load); Max. 2 points (PXR3), max. 3 points (PXR4, 5, 9) Alarm setting range: 1 to 50A. Available only when control output is relay or SSR drive Relay contact: SPST, 220 VAC/30 VDC, 1A (resistive load); 1 output point

Remote Setpoint (option) Input signal: 1 to 5 VDC, 1 point Accuracy: ±0.5% ±1 digit Input sampling cycle: 0.5 sec Input impedance: ≥1MΩ Digital Input (option) Points: 1 or 2; contact closure. 5 VDC, approx. 2mA Function (select one): Set value (SV, SV1 to 3) changeover, start/stop control action, start/reset ramp/soak action, start/stop auto-tuning, cancel alarm latch, start incorporated timer Retransmission Output (option) Output signal: 4-20 mA DC Load resistance: 500 ohms or less Output accuracy: ±0.3% FS Output selection: PV, SV, MV, DV (SV-PV) Timer Function (option) Start: By digital input option Setting: 0 to 9999 sec set in 1 sec steps Action: Event ON-delay or OFF-delay Signal output: Alarm output relays used; 2 points are available Communication Function (option) Physical specifications: EIA RS485 Protocol: Modbus (RTU). Free Windows®-based software, PXR-LITE included Connection aspect: Multi-drop up to 31 controllers Communication Total extension 500m or less distance: Operating Conditions and Structure Operating 14 to 122°F (-10 to 50°C) temperature: Mounting method: Panel flush mounting. PXR3 can be DIN-rail mounted using the optional adapter External terminal: Screw terminal


Fuji Temperature and Process Controllers SPECIFICATIONS, CONTINUED Power supply voltage: Power consumption:

Reference junction ±1°C at 23°C compensation accuracy: Dimensions (HxWxD): PXR3: 1/32 DIN (24 x 48 x 97mm). PXR4: 1/16 DIN (48 x 48 x 78.8 mm). PXR5: 1/8 DIN (96 x 48 x 78 mm). PXR9: 1/4 DIN (96 x 96 x 79.5 mm)

PXR3 ORDERING INFORMATION To order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PXR3-T-A-Y1-4-V-0A1

PXR4, 5, 9 ORDERING INFORMATION To order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PXR4-T-A-Y1-4-V-0A1

A - B - C - D - E - F - G

A - B - C - D - E - F - G

A

A

Front Panel Size PXR3 1/32 DIN (24x48mm) B Input Signal T Thermocouple (°C) R Thermocouple (°F) N RTD, Pt100 ohm, 3-wire type (°C) S RTD, Pt100 ohm, 3-wire type (°F) B 4-20mA DC, 1-5V DC A 0-20mA DC, 0-5V DC C Control Output 1 A Relay contact output C SSR or SSC drive output E 4-20mA DC output D Control Output 2 Y1 None A1 Relay contact output C1 SSR or SSC drive output E1 4-20mA DC output E Alarm Options 4 None 5 High/low alarm 1 point G High/low alarm 2 points1 F Power Supply V Standard (100-240 VAC, 50/60Hz) B 24V AC/DC (50/60Hz) G Additional Functions 0A1 None MA1 RS485 communication (Modbus) QA1 Retransmission + DI 1 point RA1 Retransmission (4-20mA DC) TA1 Digital Input (DI) x 2 VA1 RS485 communications (Modbus) + DI 1 point 1 High/low alarm 2 points not available when control output 2 is selected

B

C

D

E

F

G

ORDERING INFORMATION – ACCESSORIES CTL-6-S CTL-12 RSFC24 PXR3 Rail Adapter PXR4 Terminal Cover

Current transformer for 1-30A Current transformer for 20-50A RS485 to RS232 signal converter Mounting adapter for DIN rail installation for PXR3 Terminal block protective cover for PXR4

CONTROLLERS

100 (-15%) to 240V (+10%) AC, 50/60Hz; 24V (±10%) AC/DC PXR3: 6VA (100 V), 8VA (220V, 24V). PXR4: 8VA (100V), 10VA (220V), 12VA (24V). PXR5, 9: 10VA (100V), 12VA (220V, 24V)

Front Panel Size PXR4 1/16 DIN (48x48mm) PXR5 1/8 DIN (48x96mm) PXR9 1/4 DIN (96x96mm) Input Signal T Thermocouple (°C) R Thermocouple (°F) N RTD, Pt100 ohm, 3-wire type (°C) S RTD, Pt100 ohm, 3-wire type (°F) B 4-20mA DC, 1-5V DC A 0-20mA DC, 0-5V DC Control Output 1 A Relay contact output C SSR or SSC drive output E 4-20mA DC output1 Control Output 2 Y1 None A1 Relay contact output C1 SSR or SSC drive output E1 4-20mA DC output1 R1 Retransmission (4-20mA DC) Alarm Options 4 None 6 Heater break alarm1,2 G High/low alarm 2 points H High/low alarm 2 points + heater break alarm1,2 M Alarm 3 points D Remote setpoint3 P Remote setpoint + alarm 2 points3 Power Supply V Standard (100-240V AC, 50/60Hz) B 24V AC/DC (50/60Hz) Additional Functions 0A1 None MA1 RS485 communication (Modbus) SA1 Digital Input (DI) x 1 TA1 Digital Input (DI) x 21 VA1 RS485 communications (Modbus)+ DI1,3

1

Heater break option not available with 4-20mA output, or with 2 digital inputs, or with RS485 +1 digital input. 2 Current transformer needed with heater break option. 3 Remote setpoint option not available with RS485 +1 digital input.

8


Newport Humidity & Temperature Controllers • • • • • • • • • • •

Dual Loop Control High Accuracy ±0.5°C and ±2% RH 4 Popular DIN Sizes 2 Control or Alarm Outputs (optional) Choice of Relays, SSR, DC Pulse, Analog Voltage and Current Full Autotune PID Control Ethernet or RS-232/RS-485 (optional) User-friendly, Simple to Configure Programmable Ramp and Soak for Humidity and/or Temperature RH / Temperature Probe included NEMA 4, IP65 Front Bezel

The NEWPORT® iTH Series monitor and control both temperature and relative humidity. The meters accurately display humidity, temperature, or dew point. They also provide dual loop control for both humidity and temperature and are easily programmed for any control or alarming requirement from simple on-off to full autotune PID control. The LED displays can be programmed to change color between Green, Amber, and Red at any set point or alarm point. The iTH family is available in four true DIN sizes with NEMA 4, IP65 splash resistant bezels: the ultra compact 1/32 DIN, the popular midsize 1/16 DIN square bezel with dual display, the 1/8 DIN vertical, and the 1/8 DIN horizontal with the big bright 21mm digits.

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: NE/iTH - i8DH - 00 - 5 - C24 A – B – C – D – E – F A

SPECIFICATIONS Sensor Specifications Relative Humidity Accuracy/Range: ±2% for 10 to 90% RH 3% for 0 to 10% RH and 90 to 100% RH Non-Linearity: ±3%; Hysteresis: 1% RH Temperature Accuracy/Range*: ±0.5°C (±1°F) for 0 to 80°C (32 to 176°F) ±1°C (±2°F) for -40 to 0°C and 80 to 124°C (-40 to 32°F and 176 to 254°F) *Note: extended temperature range is for Probe only, the iTH’s operating temperature is 0-50°C. Resolution: 0.03%,12 bit for RH; 0.01°C 14 bit for Temperature Response Time: 4 sec for RH; 5 sec for Temp (63% slowly moving air) General A/D Conversion: Reading Rate: Digital Filter: Display:

12 bit RH and 14 bit Temp. 2 samples per second max. Programmable 4-digit, 9-segment LED • 10.2 mm (0.40"): i32, i16D, i8DV • 10.2 mm (0.40”) & 21 mm (0.83”): i8DH Red, green and amber programmable colors for process variable, set point and temp units Operating 0 to 50°C (32 to 122°F), Temperature: 90% RH non-condensing

8a

B

C D

E

F

Model # NE/iTH-i8DH NE/iTH-i8DV NE/iTH-i16D NE/iTH-i32 Outputs (2 digits) 0 0 2 2 2 3 2 4 3 3 4 2 4 3 4 4 5 2

Description Temperature and RH Input 1/8 DIN Dual Display Horizontal Temperature and RH Input 1/8 DIN Dual Display Vertical Temperature and RH Input 1/16 DIN Dual Display Temperature and RH Input 1/32 DIN Single Display

Monitor version, no control outputs. Two solid state relays (SSR's): 0.5 A @ 120/240 Vac continuous SSR and relay: Form “C” SPDT 3A @ 120Vac, 3A @ 240Vac SSR and pulsed 10 Vdc @ 20 mA (for use with external SSR) 2 Relays: Form “C” SPDT 3 A @ 120 Vac, 3 A @ 240 Vac Pulsed 10 Vdc @ 20 mA (for use with external SSR) and SSR Pulsed 10 Vdc @ 20 mA (for use with external SSR) and relay Two pulsed 10 Vdc @ 20 mA (for use with external SSR) Analog Output selectable as either control or retransmission of process value; 0 to 10 Vdc or 0-20 mA @ 500 ohm max. & SSR 5 3 Analog Output 0 to 10 Vdc or 0-20 mA @ 500 ohm max & Relay 5 4 Analog Out 0 to 10Vdc or 0-20mA @ 500 ohm max & Pulse 10Vdc RH/Temperature Probe (must select one) 2 2” (51mm) Probe for iTH with 3ft (0.9m) cable 5 5” (137mm) Probe for iTH with 20ft (6.1m) cable Power Supply * Standard power input: 90-240 Vac ±10%, 50-400 Hz, 110-375 Vdc, equivalent voltage (*no entry required) DC Low Voltage Power Option: 12 - 36 Vdc; 24 Vac ±10% Network Options EI Ethernet with Embedded Web Server C24 Isolated RS-232 and RS-485/422. (MODBUS & ASCII) C4EI Ethernet with Embedded Web Server + Isolated RS-485/422 hub for up to 31 devices Factory Setup FS Factory Setup and Configuration (requires Network Option)

*1 -C4EI or -EI option is not available on the 1/32 DIN. Consult Sales for other Ethernet devices that can connect to an iTH-i32xx-x-C24 .


KEP Batch Controller • Display Rate, Batch Size and Number of Batches or Grand Total • 5 Digit Scaling Factor • Pulse Input • 2 Relay Outputs • Analog Output or Serial/Modbus Options • NEMA 4X / IP65 Front Panel

• Graphical LCD Display • USB, RS485, Ethernet • Profiling & Datalogging Options • 1/4 DIN Size • Sensor Break Detection • 1-4 Relay Outputs • UL, cUL, CE

L ProVU 4

L

CONTROLLERS

West Temperature Controller

SPECIFICATIONS Input Accuracy: T/C: RTD: DC In: Sample Rate: Resolution: Aux DC In: Accuracy: Digital In: Relay Out: SSR Drive: Tuning: Protocol: LCD: Recorder: Profiler: Temperature:

±0.1% ±1d J, K, T, E, R, S, D, B, C, L, N 3-wire Pt100, Ni120 0-10V, 4-20mA 10/sec 16 bits 0-10V, 4-20mA optional ±0.25% ±1d TTL or Volt-free contact (24V max) 2A resistive 120/240VAC Dual relays have shared common >10V into >500Ω, non-isolated Pre-tune, auto pre-tune, self-tune, manual Modbus RTU or Modbus TCP Slave 160 x 80 pixel (66 x 38mm), red/green backlite 1Mb non-volatile memory 64 max, 255 segments total 0-55°C operating

ORDERING INFORMATION To Order- Insert Code for Each Letter. Example: V4-1- A – B – C – D – E – F A Type C Controller U Controller with USB D Controller/Recorder R Controller/Recorder w/USB B Profiler O None P Profiler C Supply O 100-240V AC 2 24-48V AC/DC D Option Slot 1 E, F O None O 1 Relay SPDT 1 2 DC SSR drive 2 L Linear DC output L 8 Triac Output 8 G Option Slot 4 9 O None S 1 Four SPST Relays T H Option Slot A O None 1 RS485 Serial Comm 3 Digital Input 4 Remote Setpoint 5 Ethernet I Option Slot B O None R Aux DCV, mA Input

9

V4-1-C-O-L-T-O-1-5-O-O1 – G – H – I – O1

MB2

The Mini-Batcher is a 6 digit totalizer and 4.5 digit ratemeter with two relay outputs. One output is dedicated to the batch amount (Preset A), the other can be activated for Prewarn or Batch/Grand Total. The unit can count up to the preset (reset to 0) or down from the preset (set to preset). Start, Stop and Reset functions can be activated from the front panel or remote inputs. Up to 247 units can communicate to a host computer using Modbus RTU protocol. Alternately, an analog output (assignable for Rate or Batch Amount) can be ordered for data logging.

SPECIFICATIONS Display: Input: Ratemeter Display: Accuracy: Sampling Rate: Scaling Factor: Presets: Front Panel Lockout: Relays: Relay B On Time: Power Consumption: Output Power: Operating Temperature: Memory: Dimensions: Cutout:

6 digit, 0.55" high LED Pulse, 50VDC max, 10kW resistance Units per second, minute or hour 0.01% FS (±1 digit) 2 to 24 seconds 0.0001 to 99999 (converts input pulses to engineering units) Two, 5 digits each Complete locked out (except Start/Stop) or the presets can remain accessible Two N.O. 5A, 120/240VAC or 28VDC. (N.C. contacts and NPN transistor output available with solder jumpers) 0.01 to 99.99 sec. or latched (0.00 setting) 6.5VA AC or 250mA DC max. +12VDC @ 50mA, unregulated -10 + 50% (AC powered units only) 0-54°C (32-130°F), <90% RH, non-condensing EEPROM stores data for 10 years if power is lost 4.44"W x 2.63"H x 4.25"D (113 x 67 x 108mm) 3.622" x 1.772" (92 x 45mm)

ORDERING INFORMATION Option Slot 2 & 3 None Relay SPDT DC SSR drive Linear DC output Triac Output Dual SPST Relays Dual SSR drive 24V Xmtr Power

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: KE/MB2C34 KE/MB2 A

A

B

Operating Voltage A B C

B

110 VAC ±15% or 12-15 VDC 220 VAC ±15% or 12-15 VDC 24 VAC ±15% or 12-15 VDC

Count Inputs 3 3M

C

C

4-30 VDC or 0-1VDC pulse, 10kHz max. 30mV mag. pickup, 5kHz max.

Options 1 2 3 4 A

RS232 Comm., KEP protocol RS422 Comm., KEP protocol RS232, Modbus RTU RS422/RS485, Modbus RTU Analog Output (4-20/0-20 mA)


Partlow DIN Controllers

L

• Dual 4 digit display • User selectable input type • Up to three outputs • 3 year warranty

1801+

SPECIFICATIONS Input:

SPECIFICATIONS Inputs:

Accuracy: Input Sample Rate: Impedance: Outputs:

Sensor Break Detect: Communications: Operating Temperature: Supply Voltage: Protection:

T/Cs: J, K, C, R, S, T, B, L, N, Pt 20% Rh vs. Pt40% Rh RTD: 3-wire Pt100, <50Ω per lead (balanced) DC (scalable –1999 to +9999): 0–5, 1–5, 0–10 or 2–10VDC; 0–50mV, 10–50mV; 0–20mA, 4–20mA ±0.1% of input range ±1 digit (T/C CJC better than 1°C) 4 per second; 14 bit resolution >10MΩ for T/C and mV ranges, 47kΩ for V ranges, 5Ω for mA ranges Relay: SPDT, 240VAC@2A resistive SSR Driver: >10VDC nominal into 500Ω min. DC Linear: 0–20, 4–20mA into 500Ω max.; 0–10, 1–5, 2–10, 0–5V into 500Ω min. Triac: 0.01-1A AC, 20-280Vrms, 47–63Hz <2 seconds 2-wire, RS-485, Modbus or ASCII 32–131°F (0–55°C), <95% RH non-condensing 100–240V, 50/60Hz or 20–48VAC / 22–65 VDC IP66, NEMA 4X (front panel)

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: PA/1160114300

A A

B

C

D

E

F

Basic Unit PA/1160 1160+ PID Controller (1/16 DIN) PA/1400 1400+ PID Controller (1/4 DIN) PA/1800 1800+ PID Controller (1/8 DIN) B–C–D Option Option Option Slot 1 Slot 2 Slot 3 0 0 0 None 1 1 1 Relay output 2 2 2 DC drive output for SSR 3 3 3 Linear DC output 4 4 24V Transmitter power supply* 8 8 8 Triac output* E Option Slot A 0 None 1 RS-485 serial comm 2 Green upper display 3 RS-485 & green upper display 4 Green lower display 5 RS-485 & green lower display 6 Green upper & lower display 7 RS-485 & two green displays 8 Digital input 9 Digital input & green upper display A Digital input & green lower display B Digital input & two green displays C Basic Remote Setpoint Input (RSP) D Basic RSP & green upper display E Basic RSP & green upper display F Basic RSP & two green displays F Power Supply 00 100-240VAC 02 24-48V AC/DC *max. one transmitter supply, two triac outputs per unit

CONTROLLERS

1160+

• 1/16, 1/8 & 1/4 DIN Sizes

L

• Dual setpoints with optional remote selection • Plug-in output modules • Customizable operator menus • Process and loop alarms • Full PID or ON/OFF control • Heat/Cool operation (with dual outputs) • Selectable pre-tune, self-tune, manual tune

Partlow Limit Controllers

Output:

Output Function: Control: Operating Temperature: Protection:

Thermocouple J, K, C, R, S, T, B, L, N 3 wire 100 ohm Pt RTD DC linear V (scalable –1999 to +9999) DC linear mA (0–20 or 4–20) DC linear mV (0–50 or 10–50) Relay SPDT 2A, 240VAC resisitive SSR drive >10VDC into 500Ω min Triac 0.01–1A, 20–280VAC Limit, alarm (process, deviation/band) High/low limit 0–55°C, 20–95% RH IP66, NEMA 4X front; IP20 behind panel

ORDERING INFORMATION To Order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PA/1161 010602 A

B

C

D

E

F

A Basic Unit PA/1161 1/16 DIN Limit Controller PA/1401 1/4 DIN Limit Controller PA/1801 1/8 DIN Limit Controller B Option Slot 1 0 Relay Output C Option Slot 2 0 None 1 Relay Output 2 DC drive output for SSR 3 Linear DC output 4 24V Transmitter power supply* 8 Triac output D Option Slot 3 0 None 1 Relay Output 2 DC drive output for SSR 3 Linear DC output 4 24V Transmitter power supply* 8 Triac output E Option Slot A 0 None 1 RS-485 serial comm 2 Green upper display 3 RS-485 & green upper display 4 Green lower display 5 RS-485 & green lower display 6 Green upper & lower display 7 RS-485 & two green display 8 Digital input 9 Digital input & green upper display A Digital input & green lower display B Digital input & two green displays F Power Supply 00 100–240VAC 02 24–48V AC/DC *One transmitter supply per unit

10


Newport Digital Indicator Controllers ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: Q2001-CVR6 A A

B

C

D

E F

B

C

D – E

F

Display Resolution and Case Style Q2 ±1999 Counts (31⁄2-digits) Q3 ±1999 with “Infinity™ Family Bezel and Adapter” Q9 ±9999 Counts (4-digits) Q8 ±9999 with “Infinity™ Family Bezel and Adapter” Display Type and Meter Power 0 LED, 120 VAC (49/440 Hz) (BQ20 or BQ90) 2 LED, 240 VAC (49/440 Hz) (BQ22 or BQ92) 4 LED, 9–32 VDC (isolated) (BQ24 or BQ94) 6 LED, 5 VDC** (BQ26 or BQ96) 8 LED, 24 VAC (BQ28 or BQ98) A LED, 26-–56 VDC (isolated) (BQ2A or BQ9A) **Not available with AC AVG or True RMS inputs Analog Output Adders Max one analog output in addition to recorder output 0 ±1 or ±2 V recorder output, non-isolated 1 0–5 VDC, non-isolated (BA01) 2 0–10 VDC, non-isolated (BA01) 3 0–1 mA, source or sink, non-isolated (BA01) 4 4–20 mA, source or sink, non-isolated (BA01) 6 4–20 mA, isolated (BA03) Control Output Adders 0 None 1 Dual-Setpoint 10A Relay (BDT1) 4 BCD (BDD2) 5 Single-Setpoint 10A Relay (BDS1) Signal Conditioning Input Adders ❑ Select from Input Table Green LEDs for Display G Green 0 None

INPUT TABLE Code Q2000/Q3000 Q8000/Q9000 DC Voltage Input AVR1 ±199.9 mV ±99.99 mV AVR2 ±1.999V ±999.9 mV AVR3 ±19.99V ±9.999V AVR4 ±199.9V ±99.99V DC Current Input BCR1 ±19.99 µA ±9.999 µA BCR2 ±199.9 µA ±99.99 µA BCR3 ±1.999 mA ±999.9 µA BCR4 ±19.99 mA ±9.999 mA BCR5 ±199.9 mA ±99.99 mA BCR6 ±1.999A ±999.9 mA AC AVG Voltage Input CVR2 199.9 mV 99.99 mV CVR3 1.999V 999.9 mV CVR4 19.99V 9.999V CVR5 199.9V 99.99V CVR6 650V 650.0V AC AVG Current Input DCR1 19.99 µA 9.999 µA DCR2 199.9 µA 99.99 µA DCR3 1.999 mA 999.9 µA DCR4 19.99 mA 9.999 mA DCR5 199.9 mA 99.99 mA DCR6 1.999A 999.9 mA DCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000, (4) 5A = 300, (5) 5A = 500

10a

Quanta® Standard Features • Field Selectable Input Ranges • Recorder Analog Output • Front-Panel Accessible Span Adjustment • Bright, 0.56" (14.2 mm) LED Display • Display Hold and Test • Screw-Terminal Barrier Strip • Optional Relay Outputs • 1⁄8 DIN Case Options • Analog Output for User-Selected Span • Single-Setpoint 10A SPDT Relay

• Dual-Setpoint with Two 10A SPDT Relays • Parallel BCD Output, Isolated

Quanta

INPUT TABLE (CONT’D) Code Q2000/Q3000 Q8000/Q9000 True-RMS Voltage Input FVR2 199.9 mV 99.99 mV FVR3 1.999V 999.9 mV FVR4 19.99V 9.999V FVR5 199.9V 99.99V FVR6 650V 650.0V True-RMS Current Input GCR1 19.99 µA 9.999 µA GCR2 199.9 µA 99.99 µA GCR3 1.999 mA 999.9 µA GCR4 19.99 mA 9.999 mA GCR5 199.9 mA 99.99 mA GCR6 1.999A 999.9 mA GCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000, (4) 5A = 300, (5) 5A = 500 Frequency/Rate Input (100 mV Hystersis): H 1000 Hz = 1000 1000 Hz = 0–9999 Type J Thermocouple Input JDC1 -40 to +760°C -40.0 to +760.0°C JDF1 -40 to +1400°F -40.0 to +999.9°F Type K Thermocouple Input KDC1 -40 to +1260°C -40.0 to +999.9°C KDF1 -40 to +1999°F -40.0 to +999.9°F Type T Thermocouple Input TDC1 -184 to +371°C -184.0 to +371.0°C TDF1 -300 to +700°F -300.0 to +700.0°F RTD (Pt 100) Input Alpha = 0.00385 MDC1 -200 to +830°C -200.0 to +830.0°C MDF1 -328 to +1526°F -328.0 to +999.9°F RTD Input, High Resolution Alpha = 0.00385 RDC1 -199.9 to +199.9°C Not available with Q8/Q9 RDF1 -199.9 to +199.9°F Not available with Q8/Q9 3-Wire Ratio Potentiometer Input NPR1 1000 = 1 kOhm 9999 = 1 kOhm NPR2 1000 = 5 kOhm 9999 = 5 kOhm 2- or 4-Wire Resistance Input OOR1 19.99 Ohm Not available with Q8/Q9 OOR2 199.9 Ohm Not available with Q8/Q9 OOR3 1999 Ohm Not available with Q8/Q9 OOR4 19.99 kOhm Not available with Q8/Q9 Process Signal Input P 4–20 mA = 0–100.0 4–20 mA = 0–99.99 Process Signal Input Excitation set to 15 VDC E 4–20 mA = 0–100.0 4–20 mA = 0–99.99 Strain-Gage/Microvolt Input Excitation set to 10 VDC (30 mA max) S ±100 mV = ±100.0 ±100 mV = ±99.99


Weschler Quatro BarGraph Meters • • • •

Direct Measurement of DC Current AC Current DC Voltage AC Voltage Frequency Process Loops

101 segment bargraph in red, green or tricolor 4-digit 10000 count LED display 6" edgewise & 9/64 DIN cases Vertical or horizontal orientation

Features

DIGITAL METERS

• • • • • •

Single & dual bar configurations Adjustable bargraph span Bargraph center zero mode Four programmable setpoints Front panel setpoint status indicators Up to 4 relay outputs for control and alarms • Analog retransmit option with adjustable span • Wide power supply range (AC & DC) • Sensor excitation to power 4-20mA transmitters or bridge type sensors

Bar & Digit al Style A combines a precision 4 digit LED display with a 101 segment bargraph. The bar can be set to display any part of the digital range, from a minimum of 100 counts to the full 12000 A/D counts. Higher bar resolution is useful for applications where the normal operating range is only a portion of the full scale input. Style A offers 4 levels of display brightness, which can be set from the front panel.

L Style A

Select desired code for each category to buiId the 15 digit part number. Example Part Number: MAVTRCXPD1AKXXX B

C

D

E

F

11

G

H

I

J

K

L

A

Sing le Bar Style C offers a 101 segment red, green or tricolor bar, without digital display. The bar can be set to grow from the bottom or the center of the scale. The center mode is normally used for center zero but can also show deviation around a half-scale value.

ORDERING INFORMATION

A Type L 4 digit, 9/64 DIN Case M 4 digit, 6" Edgewise Case B Style A Digital & bar C Single bar (no digtial) D Dual bar (no digital) C Orientation V Vertical H Horizontal D Bar Color R Red G Green T Tricolor (Style A or C only) E Digital Display Color R Red G Green X None (Style C or D) F Bar & Scale Position C Center bar (Style A) A Center bar, scale left or above E Cemter bar, scale right or below X Dual bar (Style D) G Second Bar Color (right or bottom bar) R Red (Style D only) G Green (Style D only) X None H Input (Partial list) AA AC Volts, scaled RMS, 200/600V AB AC Volts, scaled RMS, 200mV/2V/20V AC AC mA, scaled RMS, 2/20/200mA AD AC Amps, scaled RMS, 1A AE AC Amps, scaled RMS, 5A DE DC Volts, 2/20/200V/Custom w/Offset and 24V Excitation DF DC milliamp, 2/20/200mA w/Offset and 24V Excitation DG DC Amps, 1A DD DC Amps, 5A E1 Line Frequency, 60-500VAC, 199.9Hz, 400Hz optional (Style C or D) F2 Frequency, 50mV-30V w/24V Exc. 99.99/999.9/9999Hz (Style A) Inputs continued next column

Thermocouples RTDs Load Cells/Strain Gauges Speed Pickups/RPM Pressure Resistance/Potentiometers

XXX

Frequency, 60-500VAC 99.99/999.9/9999Hz (Style A) GF Direct Pressure, 15 psi differential (clean, dry gas) GH Direct Pressure, 30 psi diff. (dry) GK Direct Pressure, 100 psi diff (dry) M1 RPM, 99.99/999.9/9999Hz, 50mV-30V, w/24V Exc. (Style A) PD Universal Process, 2V/5V/10V/ 20V/200V/2mA/20mA PE Dual Process, (style D only) 2V/10V/20V/200V/2mA/20mA RD Resistance, 2kΩ SA Strain Gage, 5/10VDC Excitation, 20/2mV/V, 4/6-wire SD Pressure/Load Cell, 5/10V Excitation, 20/2mV/V, 4-wire TD Thermocouple, J Type (0-1400°F) (Style C or D) TE Thermocouple, K Type (0-1999°F) (Style C or D) W1 Thermocouple, J,K,R,T; Selectable °C/°F, 1°/0.1° (Style A) W2 RTD, 100Ω Pt Selectable 3/4-wire, °C/°F, 1°/0.1°, 385/392 (Style A) I Power 1 85-265VAC/95-370VDC 2 15-48VAC/10-72VDC J Retransmit A Isolated 16 Bit Output, 4-20mA V Isolated 16 Bit Output, 0-10VDC X None K Relays for Type L: 2 Two 10A Form C 4 Two 10A Form C & Two 5A Form A ** X None for Type M: B Two 10A Form C E Two 10A Form C & Two 5A Form A ** K Four 5A Form A T Four 400V 140ma AC/DC SSR X None

Style C

F3

** shared common between A & C

Dual Bar The dual bar configuration (Style D) can display two process variables, using the Dual Process input card (PE). Any combination of red and green bars can be specified. Two setpoints are available for each channel. The dual input card may also be used to display one process variable on the left bar and two tracking setpoints on the right bar. In this mode, setpoint 1 is determined by the channel 2 input signal. Setpoint 2 is offset from setpoint 1 by a fixed (user selectable) amount.

L

Style D

The dual bar style can be used with a single channel input module & 4 set points. The left bar displays the process signal; the right bar displays min/max.

SPECIFICATIONS Input Accuracy: DCV, DCA ACV, ACA Temperature Direct Pressure Frequency/RPM Strain/Load Process Resistance/Pots Bargraph Display: Bar Viewing Angle: Digital Display: Decimal Position: Relay Output: Form A (SPST) Form C (SPDT) Analog Output: mA out Volts out Power Supply: Sensor Excitation: Operating Temperature:

±(0.06% of reading + 2 counts) ±(0.07% of reading + 5 counts) ±(0.1% of reading + 3 counts) ±(1.0% of range + 3 counts) ±(0.06% of reading + 2 counts) ±(0.08% of reading + 3 counts) ±(0.06% of reading + 2 counts) ±(0.06% of reading + 2 counts) 4", 101 segment ±40° red or green, ±35° orange 4 digit LED, 0.31" (7.9mm) height Range -1999 to 9999 counts Front panel selectable n.nnn, nn.nn, nnn.n, nnnn. 5A@250VAC, 5A@30VDC (resistive) 10A@240VAC, 8A@24VDC (resistive) Isolated 16 bit, user scalable 4-20mA, 500Ω maximum loop resistance 0-10VDC, 500Ω minimum load resistance 85-265 VAC / 95-370 VDC @ 2.5W (4.2W) 18-48 VAC / 10-72 VDC @ 2.5W (4.2W) 24V @ 50mA (2-wire loop power) 10V @ 120mA (bridge excitation) 0 to 60°C, 95% RH (non-condensing)


Weschler Tri-Color Bargraph Meters • Large, bright display with 16 step dimming • 40, 50 or 100 segment Tri-Color Bar • Bar changes color at user adjustable setpoints — Red, Green, Amber • 5 or 6 digit resoluton • Versatile selection of inputs • Up to 6 form A or 4 form C relay outputs • Peak/Valley option • RS232, RS485 & Ethernet Communications • Analog retransmit option • AC or DC power • Rugged case DIGITAL METERS

Sizes to replace popular edgewise and circular analog meters.

CONFIGURATION OPTIONS SIZE BG252 BH252 BV5A BD101 BG241 BG261 BG281

6" Vertical BarGraph 6" Horizontal BarGraph 7 1/2" Vertical BarGraph 10" Vertical BarGraph 4 1/2" Square BarGraph 8 1/2" Square BarGraph 8" Circle BarGraph

INPUT DC Volts DC Amps AC Volts RMS AC Amps RMS Process

Over 10,000 combinations available.

L

BG261TC

COMMUNICATION RS232 RS485 Ethernet ModBus RETRANSMIT 4-20mA 0-1mA 1-5V DC 0-1V DC 10-50mA DC Excitation Power 24 VDC

L

Line Frequency MAG Pickup Thermocouple RTD Watts VARs Power Factor

50mV to 250V full scale 50µA to 5A full scale 50mV to 250V full scale 1mA to 5A full scale 4-20mA DC 1-5V DC 10-50mA DC 55-65 Hz 50Hz-20kHz J, K or T 100 ohm Pt or 10 ohm Cu Single & polyphase

POWER 120V AC 50/60Hz 240V AC 50/60Hz 12V DC 24V DC 28V DC 48V DC 125V DC 250V DC 120V AC / 125V DC

BD101TC

DIGITAL DISPLAY COLOR Green Amber Red

FIELD PROGRAMMABLE FUNCTIONS • Zero and full scale point location • Setpoint type (Hi or Low) • Hysteresis & latching • Setpoint time delay • 16 step dimming • Digital display for engineering units • Enable/disable front buttons • I.D. selection for communication • Bar form • Peak / Valley enable • Color zones • Over / Under range, flashing • Lamp test

L

BH252TC More information online at weschler.com/bargraph

12


Weschler Bargraph Meters • Precise digital & vivid proportional (bar) display • 101 segment single color bar, up to 10" high • 3 1/2, 4 1/2 or 5 1/2 digit resolution • Versatile selection of inputs • Up to 6 form A or 4 form C relay outputs • Peak/Valley option • Analog retransmit option • AC or DC power • Rugged case

INPUT DC Volts DC Amps AC Volts RMS AC Amps RMS Process

Line Frequency MAG Pickup Thermocouple RTD Watts VARs Power Factor

6" Vertical BarGraph 6" Horizontal BarGraph DIN Size Vertical BarGraph DIN Size Horizontal BarGraph DIN Size Dual BarGraph Single BarGraph Dual BarGraph 6" Vertical BarGraph 6" Vertical BarGraph 7 1/2" Vertical BarGraph 10" Vertical BarGraph 4 1/2" Square BarGraph 8 1/2" Square BarGraph 8" Circle BarGraph 6" Circle BarGraph

50mV to 250V full scale 50µA to 5A full scale 50mV to 250V full scale 1mA to 5A full scale 4-20mA DC 1-5V DC 10-50mA DC 55-65 Hz 50Hz-20kHz J, K or T 100 ohm Pt or 10 ohm Cu single & polyphase

POWER 120V AC 50/60Hz 240V AC 50/60Hz 5V DC 12V DC 24V DC 28V DC 48V DC 125V DC 250V DC 120V AC / 125V DC SETPOINTS Hi/Lo Hi/Hi-Hi Lo/Lo-Lo Hi-Hi/Hi/Lo/Lo-Lo COMMUNICATION RS232 RS485 Ethernet ModBus RETRANSMIT 4-20mA 0-1mA 1-5V DC 0-1V DC 10-50mA DC Excitation Power 24 VDC LED COLOR Green Amber Red BAR COLOR Green Amber Red

Over 10,000 combinations available. For more information see weschler.com/bargraph

13

L

BG241

L

SIZE BG252 BH252 PC101 PH101 PC202 PG101 PG202 BI1251 BW1316 BV5A BD101 BG241 BG261 BG281 BG251

BG252 PC202

L

DIGITAL METERS

CONFIGURATION OPTIONS


Dixson Bargraph Meters/Controllers • • • • •

Fit Standard Switchboard Cutouts Red, Green or Amber LED Bar Precise 4 Digit Readout Underrange/Overrange Indication On/Off Control via Setpoint Relays

• • • •

Isolated Retransmit Option Transducer Excitation Supply Minimum 88,000 hour MTBF Two Year Warranty

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number Order Example: BBVRR1RAY1VDL1BX

L

L

BW051P

BK051P

SPECIFICATIONS Input Ranges: 50mV to 250V

DC Current

50mA to 250mA

AC Volts

250mV to 250V

AC Current

1mA to 5A

Thermocouple

J, K, T, E

RTD

Pt 100

DC Accuracy:

±0.04% of span ±1d

AC Accuracy:

±0.5% of span, above 5% of range

Digital Display:

4 digit LED, 0.01% resolution

Enclosure:

Plastic, UL94 V0 or V1

Setpoint Relays:

Form C, 0.4A@125VAC, 2A@30VDC

Setability:

0.1%, with 1.0% hysteresis

Operating temperature: 0 to 60°C 115/230VAC, 50/60/400Hz, 4VA/channel DC power available Line Regulation:

±10%

BB101P, BB202P

Bar Segments: 101

BW051P

BK051P

C

D

E

F

G

H

I

J

K

Dimensions:

2.16"W x 6"H x 5.8"D

Panel Cutout:

1.77" x 5.7"

Orientation:

Vertical or horizontal

Bar Segments: 51 Dimensions:

4.625" x 4.625" x 6.7"D

Panel Cutout:

4" dia ANSI switchboard

Bar Segments: 51 Dimensions:

3.82"W x 11.25"H x 7.10"D

Panel Cutout:

1.77" x 5.7"

L

M

N

O

Basic Unit BW BW051P BK BK051P V

Vertical

R S

Red (Standard) Mixed (BW051/BK051 Only) Tricolor

T

DC Volts

Power:

B

DIGITAL METERS

A

A Basic Unit BB BB101P BC BB202P (101 Segements each side)* B Bargraph Orientation H Horizontal (BP101P Only) C Bargraph Color A Amber G Green

D 4-Digit Display X None G Green A Amber R Red (Standard) E Decimal Location 1 000.0 3 0.000 2 00.00 X 0000 F Setpoint Options (Must be ordered with Alarm Setpoint) (G) X None A Amber R Red (Standard) G Green G Alarm Setpoint (Must be ordered with Setpoint Option (F) X None L Low/Low H High/High A High/Low H Program Switches X None Y Yes (Standard) I Primary Power 1 115 VAC 4 24 VDC 2 230 VAC 6 12 VDC 5 5 VDC 8 48 VDC J Signal Inputs A Amperes M Milliamperes B Millivolts O Other C Degrees C U Microamperes F Degrees F V Volts K Signal Type A AC D DC O RTD or TC L Signal Linearity L Linear Q Square Root X Non-linear (TC, RTD, custom) M Special Options X None 1 Isolated 2-wire retransmit 3 Auxiliary supply A AC/DC converter (for AC in) B DC amp (for <1V FS in) R RTD in J Type J TC in K Type K TC in E Type E TC in S Combination of the above N Bar Start B Bottom C Center T Top O Terminals/Conformal Coating X Standard/none Y Standard/coated B Barrier strip terminals E End cap S Combination of the above *Specify both sides for BB202P

14


Texmate Intelligent Panel Meters Tiger Family Features

TIGER FAMILY

Intelligent Meter Controllers with Programmable Logic, Digital Signal Processing Capabilities & Serial Communication

L DI-50E

L DI-60AE

DIGITAL METERS

1/8 DIN 96X48mm

L DI-60E

L GI-50E

1/8 DIN 96X48mm

9/32 DIN 144x72mm

LEOPARD FAMILY

Smart, Programmable Meter Relays with Isolated Retransmit or Control Loop Outputs DL-40

L

1/8 DIN 96X48mm

• Intelligent and super-intelligent digital meters • Front-panel digital calibration and function selection • Built-in linearization function, 32 to 125 flexible points • Built-in sensor excitation voltage 5 V /10 V / 24 V DC • Six 5A relays or combinations of 10A relays and 5A relays • Built-in memory for maximum and minimum readings • Over 75 signal conditioners, single as well as dual inputs • Two high-resolution, independently programmable 16-bit analog outputs • Built-in timer and totalizer (signal integration) inputs, plus user-definable macros and real time clock • Choice of serial communications – RS232, RS485, Ethernet, ASCII, Modbus and direct drive printer output • Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC or 15-48 V AC / 10-72 V DC power supply • Digital “smart” filtering • Computer programmable • Data logging up to 7000 samples

Leopard Family Features • Smart 4-digit meters • Front-panel digital scaling, offset, and setpoints • Over 38 different signal conditioners • Dual 10 and 5-amp relays, 4 relays total plus analog output • 1/16 DIN meters have 2 or 3 relays or 1 relay plus analog output • Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC, or 15-48 V AC / 10-72 V DC power supply

L

Lynx Family Features

L

DL-40 LR

BL-40

1/16 DIN 96X24mm

• Basic indicator 3.5, 4 or 5 digit, 0.56” and 0.8” LED meters • Analog scaling and offset from rear • Over 24 single-input signal conditioners available • Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC, or 15-48 V AC / 10-72 V DC power supply

SPECIFICATIONS LYNX FAMILY

Configured for Direct Connection to Most Sensors and Process Signals, with Displays Scalable to Any Unit of Measure

1/8 DIN 96X48mm

L DX-35 LR

L DX-35

L DX-40 LR

L DX-45

L BX-35

L BX-45

1/16 DIN 96X24mm

15

Tiger Meter Specifications Accuracy: Built-in compensation and linearization functions enable system accuracies of the order of ±0.0001% of reading for analog inputs. Stop Start time resolution from ±1sec to ±0.7nsec. Digital input and pulse counts ±1 count. A/D Convertors: A Dual Slope, bipolar 17 bit A/D is provided as standard on the main board. SMART modules have 24 bit or 16 bit Delta-Sigma A/D convertors that utilize the internal I2C BUS. Temperature Coefficient: Typically 30ppm/˚C. Compensation can be utilized to achieve system temperature coefficients of 1ppm. Warm Up Time: Up to 10 minutes, depending on input module. Conversion Rate: Typically 10 samples per second. However, SMART input modules are available that can convert at 60, 240, 480 or 960 samples per second. Control Output Rate: Can be selected for 100msec or 10msec. Some SMART modules have SSR outputs that react within 1.2msec. Excitation Voltage: Depends on input module selected. Typically, 5V, 10V or 24VDC is provided. Operating Temperature: 0 to 50 ˚C (32 ˚F to 122 ˚F). Storage Temperature: -20 ˚C to 70 ˚C (-4 ˚F to 158 ˚F). Relative Humidity: <95% (non-condensing) at 40 ˚C (104 ˚F). Case Options: NEMA 4X Lens cover Metal case surround Panel Adapters


Texmate Intelligent Panel Meters LYNX FAMILY METER SELECTION

Leopard Meter Specifications A/D Converter: Accuracy: Temperature Coefficient: Warm Up Time: Conversion Rate: Operating Temperature: Storage Temperature:

14 bit single slope ±(0.05% of reading + 2 counts) 100 ppm/°C (Typical) 2 minutes 5 conversions per second (Typical) 0 to 60°C, <95% (non condensing) –20°C to 70°C

A

B

Lynx Meter Specifications 12 bit dual slope ±(0.05% of reading + 2 counts) 100 ppm/°C (Typical) 2 minutes 3 conversions per second (Typical) 0 to 60°C, <95% (non condensing) –20°C to 70°C

C D E

ORDERING INFORMATION

INPUT MODULE SELECTION

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: DI-50E-DR-PS1-IA01-IAC-S2-R1

Function

Basic Unit

AC

A – B – C – D – E – F – G

TIGER FAMILY METER SELECTION A B

C D E F

G

Intelligent Modular, 32 pt Linear, Analog out & relays DI-50E DI-60AE Intelligent Modular, Alpha Numeric 6 digit 0.56” LED DI-60E Intelligent Modular, Numeric 6 digit 0.56” LED GI-50E Intelligent Modular, w/ 5 digit 1” LED Display DR Red LED DG Green LED DB Super-bright Red LED Power Supply PS1 85-265VAC/95-370VDC PS2 15-48VAC/10-72VDC Input Modules – See Input Module List "T" Items Output Options AIC Isolated 4 to 20 mA Analog Output AIV Isolated 0 to 10 VDC Analog Output Serial Communications S2 Isolated RS-232 communication + ASCII S4 Isolated RS-485 communication + ASCII S5 Isolated ModBus Compatible + ASCII S9 Ethernet Modbus TCP/IP Relays R1 Single 5A Form A Relay R2 Two 5A Form A Relays Six 5A Form A Relays R6 R13 Two 10A Form C Relays, One 5A Form A Relay Two 10A Form C Relays, Two 5A Form A Relays R14

LEOPARD FAMILY METER SELECTION A

B

C D E F

BL-40 4.0 digit, Modular, Low Profile, Half Height Case BL-40H 4.0 digit, Thermocouple & RTD, Half Height Case DL-40 4.0 digit, Modular, 1/8 DIN case DL-40H 4.0 digit, Thermocouple & RTD, 1/8 DIN Case Display DR Red LED, 0.56 inch high DG Green LED, 0.56 inch high DB Super bright LED, 0.56 inch high LG Large Green LED, 0.8 or 1 inch high LR Large Red LED, 0.8 or 1 inch high Power Supply PS1 85-265VAC/95-370VDC PS2 15-48VAC/10-72VDC Input Modules – See Input Module List "L" Items Output Options AIC Isolated 4 to 20 mA Analog Output AIV Isolated 0 to 10VDC Analog Output Relays R1 Single 10A Form A Relay R2 Two 10A Form A Relay R3 Two 10A Form A Relays, One 5A Form A Relay Two 10A Form A Relays, Two 5A Form A Relays R4

DIGITAL METERS

A/D Converter: Accuracy: Temperature Coefficient: Warm Up Time: Conversion Rate: Operating Temperature: Storage Temperature:

BX-35 3.5 Digit Universal Power Supply, 1/16 DIN Case BX-45 4.5 Digit Universal Power Supply, 1/16 DIN Case DX-35 3.5 Digit Universal Power Supply, 1/8 DIN Case DX-40 4 Digit Universal Power Supply, 1/8 DIN Case DX-45 4.5 Digit Universal Power Supply, 1/8 DIN Case Display DR Red LED DG Green LED DB Super-bright Red LED LG Large Green LED, 0.8 inch high LR Large Red LED, 0.8 inch high Power Supply PS1 85-265VAC/95-370VDC PS2 15-48VAC/10-72VDC Input Modules – See Input Module List "LY" Items Output Options AIC Isolated 4 to 20 mA Analog Output AIV Isolated 0 to 10VDC Analog Output Module

For

AC 1A, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA04 . . . . . . . T,L,Ly AC 5A, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA05 . . . . . . . T,L,Ly AC 1A, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA09 . . . . . . . T,L,Ly AC 5A, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA11 . . . . . . . T,L,Ly AC 2/20/200mA, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA03 . . . . . . . T,L,Ly AC 2/20/200mA, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA08 . . . . . . . T,L,Ly AC 100mV, Scaled RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA10 . . . . . . . T,L,Ly AC 100mV, True RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA12 . . . . . . . T,L,Ly AC 200/600V, Scaled RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA01 . . . . . . . T,L,Ly AC 200mV/2V/20V, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA02 . . . . . . . T,L,Ly AC 200/600V, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA06 . . . . . . . T,L,Ly AC 200mV/2V/20V, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA07 . . . . . . . T,L,Ly

DC DC 5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID04. . . . . . . T,L,Ly DC 1A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID09. . . . . . . T,L,Ly DC 2/20/200mA w/ 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID03. . . . . . . T,L,Ly DC 2/20/200mA w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . ID07. . . . . . . T,L,Ly DC 20/50/100/200mV w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . ID02. . . . . . . T,L,Ly DC 2/20/200V/Custom w/ 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . . . ID01. . . . . . . T,L,Ly DC 2/20/200V/Custom w/ Ext. Decimal Select . . . . . . . . . . . . . . . . ID06 . . . . . . . . T DC 2/20/200V/Custom w/ External LIN Table Select . . . . . . . . . . . ID08 . . . . . . . . T DC 2/20/200V/Custom w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . ID05. . . . . . . T,L,Ly DC Watts, 200V & 50mV from shunt . . . . . . . . . . . . . . . . . . . . . . . . . IW03 . . . . . . . . T DC 2V and 3-wire RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT3. . . . . . . . . T Dual DC 2mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD3 . . . . . . . . T Dual DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD2 . . . . . . . . T Dual DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD1 . . . . . . . . T DC 50mV and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD6 . . . . . . . . T DC 2V and 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD5 . . . . . . . . T DC 2V and 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD4 . . . . . . . . T DC 50mV and J K R S T B N Thermocouple . . . . . . . . . . . . . . . . . . . . . IDT5. . . . . . . . . T DC 2V and J K R S T B N Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . IDT4. . . . . . . . . T DC 1-5V Process w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . IP03 . . . . . . . T,L,Ly DC 2/5/10/20V/2/20mA + 3 Digital Inputs. . . . . . . . . . . . . . . . . . . IP10. . . . . . . . . T Triple DC 50mV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD2. . . . . . . . . T Triple DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD1. . . . . . . . . T DC 50mV and 50mV and J K R S T B N T/C. . . . . . . . . . . . . . . . . . . . . ITT6 . . . . . . . . . T DC 50mV and 2V and J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . ITT9 . . . . . . . . . T DC 2V and 2V and J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . ITT7 . . . . . . . . . T DC 50mV and two J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . ITT5 . . . . . . . . . T DC 2V and two J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITT3 . . . . . . . . . T DC Volts and T/C and Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITTG . . . . . . . . . T Quad DC 50mV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD2 . . . . . . . . T Quad DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD1 . . . . . . . . T RTD + DC V + DC V + Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQT5. . . . . . . . . T Smart DC V, 16 bit, 1 to 800 Hz update rates . . . . . . . . . . . . . . . . . ISD1* . . . . . . . T Smart DC V, 16 bit, 1 to 960 Hz update rates . . . . . . . . . . . . . . . . . ISD2** . . . . . . T Smart DC V, 16 bit, 1 to 800 Hz w/dual SSRs . . . . . . . . . . . . . . . . . ISD3* . . . . . . . T Smart DC V, 16 bit, 1 to 960 Hz w/dual SSRs . . . . . . . . . . . . . . . . . ISD4** . . . . . . T Smart DC V, High Res & Acc, 24 bit 1-400Hz . . . . . . . . . . . . . . . . . . ISD5* . . . . . . . T Smart DC V, High Res & Acc, 24 bit 1-480Hz . . . . . . . . . . . . . . . . . . ISD6** . . . . . . T Smart DC V, High Res & Acc, 1-400Hz w/dual SSRs . . . . . . . . . . . . ISD7* . . . . . . . T Smart DC V, High Res & Acc, 1-400Hz w/dual SSRs . . . . . . . . . . . . ISD8** . . . . . . T Smart Dual 3-wire Potentiometer (50 Hz) . . . . . . . . . . . . . . . . . . . . . ISR3* . . . . . . . T Smart Dual 3-wire Potentiometer (60 Hz) . . . . . . . . . . . . . . . . . . . . . ISR4** . . . . . . T Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . . . . . . . . . . . . . . . . ISDA* . . . . . . . T Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . . . . . . . . . . . . . . . . ISDB** . . . . . . T Smart Load Cell and RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISSB. . . . . . . . . T DC Process 2/5/10/20/200V/2/20mA w/ 24V Exc.. . . . . . . . . . . . IP07 . . . . . . . . T,L DC Process 2/5/10/20/200V/2/20mA w/ 24V Exc & AutoCal . . . IP08. . . . . . . . . T

16


Texmate Intelligent Panel Meters Module For

COUNTER Quadrature Counter . . . . . . . . . . . . . . . . . . . . . . . . IC02 . . . T Quadrature Counter w/dual SSRs. . . . . . . . . . . . . IC03 . . . T Universal Freq./ RPM / Up Down Counter . . . . . . IF10 . . . T Dual UP/DOWN Counter. . . . . . . . . . . . . . . . . . . . . IDC1 . . . T Counter and T/C and 4-20mA . . . . . . . . . . . . . . . . ITTF . . . T Smart Dual Counter and Pressure Direct . . . . . . . ISP1 . . . T

DIGITAL METERS

DUAL INPUTS 3-wire RTD and DC V . . . . . . . . . . . . . . . . . . . . . . . IDT3 . . . T 3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T Dual DC 2mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD3. . . T Dual DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD2. . . T DC 50mV and 4-20mA . . . . . . . . . . . . . . . . . . . . . . IDD6. . . T DC 2V and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . IDD5. . . T DC 2V and DC 50mV . . . . . . . . . . . . . . . . . . . . . . . IDD4. . . T Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T Dual DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD1. . . T Dual Direct Pressure (Abs. or Differential/Gage). . . IGYY . . . T Dual Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDF2 . . . T Dual Pressure Input . . . . . . . . . . . . . . . . . . . . . . . . IDS2 . . . T Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T Dual Resistance Input . . . . . . . . . . . . . . . . . . . . . . IDR1. . . T Dual RTD Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT2 . . . T Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS5* . . T Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS6** . T Dual Strain Gage Input. . . . . . . . . . . . . . . . . . . . . . IDS1 . . . T Dual Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . IDT1 . . . T Thermocouple and 4-20mA . . . . . . . . . . . . . . . . . . IDP3 . . . T Thermocouple and DC mV . . . . . . . . . . . . . . . . . . . IDT5 . . . T Thermocouple and DC V . . . . . . . . . . . . . . . . . . . . IDT4 . . . T Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T Dual UP/DOWN Counter. . . . . . . . . . . . . . . . . . . . . IDC1 . . . T Smart Dual 3-wire Potentiometer . . . . . . . . . . . . . ISR3 . . . T Smart Load Cell and Process (4-20mA) . . . . . . . . . ISS9 . . . T Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . ISDA* . . T Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . ISD8**. T Smart Dual Photo Diode Input. . . . . . . . . . . . . . . . ISSE . . . T Smart Dual RTD (50Hz) . . . . . . . . . . . . . . . . . . . . . IST5* . . T Smart Dual RTD (60Hz) . . . . . . . . . . . . . . . . . . . . . IST6** . T

4 - 20mA 3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T DC 50mV and 4-20mA . . . . . . . . . . . . . . . . . . . . . . IDD6. . . T DC 2V and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . IDD5. . . T Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T Thermocouple and 4-20mA . . . . . . . . . . . . . . . . . . IDP3 . . . T Process Loop 4-20mA . . . . . . . . . . . . . . . . . . . . . . IP01 . T,L,Ly Process Loop 4-20mA w/ Ext. Lin Table . . . . . . . IP09 . T,L,Ly Process Loop 4-20mA w/ 24V Exc. & AutoCal . . IP06 . . . T Process Loop 4-20mA w/ 24V Exc. . . . . . . . . . . . IP02 . T,L,Ly Quad 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQP1 . . . T Smart Load Cell and Process 4-20mA . . . . . . . . . . ISS9 . . . T Triple 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITP1 . . . T 4-20mA and 4-20mA and T/C . . . . . . . . . . . . . . . . ITT8 . . . T T/C and 4-20mA and Counter . . . . . . . . . . . . . . . . ITTF . . . T T/C and 4-20mA and DC mV . . . . . . . . . . . . . . . . . ITTA . . . T T/C and 4-20mA and DC Volts . . . . . . . . . . . . . . . ITTB . . . T T/C and 4-20mA and Frequency . . . . . . . . . . . . . . ITTF . . . T T/C and T/C and 4-20mA . . . . . . . . . . . . . . . . . . . ITT4 . . . T

FREQUENCY / RPM Universal Freq./ RPM / Up Down Counter . . . . . . IF10 . . . T Universal Frequency / RPM . . . . . . . . . . . . . . . . . . IF05 . . . L Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF08 . . . L Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF06 . . . T Dual Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDF2 . . . T Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T T/C and 4-20mA and Frequency . . . . . . . . . . . . . . ITTF . . . T T/C and DC Volts and Frequency. . . . . . . . . . . . . . ITTG . . . T RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T

LVDT Smart Dual LVDT (50 Hz) . . . . . . . . . . . . . . . . . . . . ISL1* . . T Smart Dual LVDT (60 Hz) . . . . . . . . . . . . . . . . . . . . ISL2** . T

OXIDATION REDUCTION POTENTIAL Oxidation Reduction Potential (ORP). . . . . . . . . . . IOR1. . . T

pH pH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IH01 . . . T pH w/ Automatic Temperature Compensation . . . IH02 . . . T

17

Module For

3-wire Potentiometer 1kΩ min. . . . . . . . . . . . . . . . IR02 . T,L,Ly Linear Potentiometer 1kΩ min . . . . . . . . . . . . . . . IR03 . . T,L Smart Dual 3-wire Potentiometer (50 Hz). . . . . . . ISR3* . . T Smart Dual 3-wire Potentiometer (60 Hz). . . . . . . ISR4**. T Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T Smart Single 3-wire Potentiometer (50 Hz) . . . . . ISR1* . . T Smart Single 3-wire Potentiometer (60 Hz) . . . . . ISR2**. T

PRESSURE / LOAD CELL Universal Direct Pressure . . . . . . . . . . . . . . . . . . . . IGYZ . T,L,Ly Direct Pressure with 2 Digital Inputs . . . . . . . . . . IGYX . . . T Dual Direct Pressure (Abs. or Differential/Gage) . IGYY . . . T Dual Pressure Input . . . . . . . . . . . . . . . . . . . . . . . . IDS2 . . . T Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS5* . . T Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS6** . T Pressure/Load Cell 20/2mV/V, 5/10V Exc, 4-wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IS05 . T,L,Ly Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire. . IS06 . T,L,Ly Pressure/Load Cell Ext Exc., High Impedance . . . IS07 . . T,L Pressure/Load Cell Ext Exc., 4/6-wire. . . . . . . . . . IS04 . . T,L Pressure/Load Cell w/ AutoCal, 4-wire . . . . . . . . . IS03 . . . T Pressure/Load Cell, 4/6-wire. . . . . . . . . . . . . . . . . IS02 . . T,L Smart Pressure/Load Cell, Standard Res 16 bit . ISS1* . . T Smart Pressure/Load Cell, Standard Res 16 bit . ISS2** . T Smart Pressure/Load Cell, High Res & Acc 24 bit . ISS3* . . T Smart Pressure/Load Cell, High Res & Acc 24 bit . ISS4** . T Smart Quad Pressure/Load Cell (50 Hz) . . . . . . . ISS7* . . T Smart Quad Pressure/Load Cell (60 Hz) . . . . . . . ISS8** . T Smart Pressure Direct & Dual Counter. . . . . . . . . . ISP1 . . . T Smart Load Cell and Process 4-20mA . . . . . . . . . . ISS9 . . . T Smart Load Cell and RTD. . . . . . . . . . . . . . . . . . . . ISSB . . . T Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSC* . . T Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSD**. T Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T

PROCESS LOOP Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T Process Loop 4-20mA . . . . . . . . . . . . . . . . . . . . . . IP01 . T,L,Ly Process Loop 4-20mA w/ Ext. Lin Table . . . . . . . . . . IP09 . . . T Process Loop 4-20mA w/ 24V Exc. & AutoCal. . . . . . IP06 . . . T Process Loop 4-20mA w/ 24V DC Exc. . . . . . . . . IP02 . T,L,Ly

QUAD INPUTS Quad 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQP1 . . . T Quad DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD2. . . T Quad DC 2V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD1. . . T Quad RTD Platinum 2 wire connection. . . . . . . . . IQT2 . . . T Quad RTD Platinum 4 wire connection. . . . . . . . . IQT4 . . . T RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T Smart Quad Pressure/Load Cell (50 Hz) . . . . . . . ISS7* . . T Smart Quad Pressure/Load Cell (60 Hz) . . . . . . . ISS8** . T Smart Quad Thermocouple (50 Hz) . . . . . . . . . . . IST3* . . T Smart Quad Thermocouple (60 Hz) . . . . . . . . . . . IST4** . T

RESISTANCE Dual Resistance 0.2/2/20kΩ . . . . . . . . . . . . . . . . IDR1. . . T Resistance 200/2k/20kΩ, 2/3/4-Wire . . . . . . . . IR01 . . . T Resistance 2kΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . IR04 . . . L Resistance 2kΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . IR05 . . Ly Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T Smart Voltage and Resistance . . . . . . . . . . . . . . . ISD9 . . . T

RTD 3-wire RTD and DC V . . . . . . . . . . . . . . . . . . . . . . . IDT3 . . . T 3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T Dual RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT2 . . . T Quad RTD Platinum 2 wire. . . . . . . . . . . . . . . . . . . IQT2 . . . T Quad RTD Platinum 4 wire. . . . . . . . . . . . . . . . . . . IQT4 . . . T RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T RTD, 10Ω Copper 2/3/4-wire . . . . . . . . . . . . . . . . IT13 . . . T RTD, 100Ω Pt. 2/3/4-wire . . . . . . . . . . . . . . . . . . . IT02 . . . T RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9˚C). . IT14 . T,L,Ly RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9°F). . IT05 . T,L,Ly RTD, 100Ω Pt. 2/3/4-wire (-200 to 800°C) . . . . . IT03 . T,L,Ly RTD, 100Ω Pt. 2/3/4-wire (-200 to 1470°F) . . . . IT04 . T,L,Ly RTD, 100Ω Pt. 3/4-wire, °C/°F, 1°/0.1°. . . . . . . IT11 . . . L RTD, 120Ω Nickel 2/3/4-wire . . . . . . . . . . . . . . . . IT12 . . . T RTD, 1000Ω Pt. Select 3/4-wire, °C/°F, 1°/0.1° . IT15 . . . L Smart Load Cell and RTD. . . . . . . . . . . . . . . . . . . . ISSB . . . T Smart Dual RTD (50Hz) . . . . . . . . . . . . . . . . . . . . . IST5* . . T Smart Dual RTD (60Hz) . . . . . . . . . . . . . . . . . . . . . IST6** . T Smart 6 Input - 3 RTD, 2 Process, 1 Digital . . . . . IST1* . . T Smart 6 Input - 3 RTD, 2 Process, 1 Digital . . . . . IST2** . T Triple RTD Platinum 100Ω, 4-wire . . . . . . . . . . . . . ITTC . . . T

Function Module For Triple RTD Platinum 100Ω, 2-wire . . . . . . . . . . . . . ITT2 . . . T RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T

SINGLE PHASE POWER Single Phase Power, 300V/1A. . . . . . . . . . . . . . . . IW01 Single Phase Power, 300V/5A. . . . . . . . . . . . . . . . IW02 Single Phase Power, 600V/1A. . . . . . . . . . . . . . . . IW04 Single Phase Power, 600V/5A. . . . . . . . . . . . . . . . IW05

..T ..T ..T ..T

STRAIN GAGE Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T Dual Strain Gage. . . . . . . . . . . . . . . . . . . . . . . . . . . IDS1 . . . T Strain Gage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IS01 . . T,L

THERMOCOUPLE Dual Thermocouple J K R ST B N . . . . . . . . . . . . . . IDT1 . . . T T/C J K R ST B N and 4-20mA. . . . . . . . . . . . . . . . . IDP3 . . . T T/C J K R ST B N and DC 50mV . . . . . . . . . . . . . . . IDT5 . . . T T/C J K R ST B N and DC 2V . . . . . . . . . . . . . . . . . . IDT4 . . . T Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T Smart Quad Thermocouple (50 Hz) . . . . . . . . . . . IST3* . . T Smart Quad Thermocouple (60 Hz) . . . . . . . . . . . IST4** . T Thermocouple J K R ST B N . . . . . . . . . . . . . . . . . . . IT01 . . . T T/C, J K RT, Selectable°C/°F, 1°/0.1° . . . . . . . . IT10 . . . L T/C J K R ST B N , 4-20mA and 4-20mA . . . . . . . . . ITT8 . . . T T/C J K R ST B N , 4-20mA and Counter. . . . . . . . . . ITTF . . . T T/C J K R ST B N , 4-20mA and DC 50mV. . . . . . . . ITTA . . . T T/C J K R ST B N , 4-20mA and DC 2V. . . . . . . . . . . ITTB . . . T T/C J K R ST B N , DC 50mV and DC 50mV . . . . . . ITT6 . . . T T/C J K R ST B N , DC 2V and DC 50mV . . . . . . . . . ITT9 . . . T T/C J K R ST B N , DC 2V and DC 2V . . . . . . . . . . . . ITT7 . . . T T/C J K R ST B N , T/C and 4-20mA . . . . . . . . . . . . . ITT4 . . . T T/C J K R ST B N , T/C and DC 50mV . . . . . . . . . . . ITT5 . . . T T/C J K R ST B N , T/C and DC 2V . . . . . . . . . . . . . . ITT3 . . . T T/C, 4-20mA and Frequency . . . . . . . . . . . . . . . . . ITTF . . . T T/C, DC Volts and Frequency . . . . . . . . . . . . . . . . . ITTG . . . T Triple Thermocouple J K R ST B N . . . . . . . . . . . . . ITT1 . . . T

TRIPLE INPUTS Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSC* . . T Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSD**. T Smart Pressure Direct & Dual Counter . . . . . . . . . . ISP1 . . . T Triple 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITP1 . . . T Triple DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD2 . . . T Triple DC 2V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD1 . . . T Triple RTD Platinum 100Ω, 4-wire . . . . . . . . . . . . . ITTC . . . T Triple RTD Platinum 100Ω, 2-wire . . . . . . . . . . . . . ITT2 . . . T RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T T/C J K R ST B N , 4-20mA and 4-20mA . . . . . . . . . ITT8 . . . T T/C J K R ST B N , 4-20mA and Counter. . . . . . . . . . ITTF . . . T T/C J K R ST B N , 4-20mA and DC 50mV. . . . . . . . ITTA . . . T T/C J K R ST B N , 4-20mA and DC 2V. . . . . . . . . . . ITTB . . . T T/C J K R ST B N , DC 50mV and DC 50mV . . . . . . ITT6 . . . T T/C J K R ST B N , DC 2V and DC 50mV . . . . . . . . . ITT9 . . . T T/C J K R ST B N , DC 2V and DC 2V . . . . . . . . . . . . ITT7 . . . T T/C J K R ST B N , T/C and 4-20mA . . . . . . . . . . . . . ITT4 . . . T T/C J K R ST B N , T/C and DC 50mV . . . . . . . . . . . ITT5 . . . T T/C J K R ST B N , T/C and DC 2V . . . . . . . . . . . . . . ITT3 . . . T T/C, 4-20mA and Frequency . . . . . . . . . . . . . . . . . ITTF . . . T T/C, Volts and Frequency . . . . . . . . . . . . . . . . . . . . ITTG . . . T Triple Thermocouple J K R ST B N . . . . . . . . . . . . . ITT1 . . . T *Optimized for 50 Hz rejection. **Optimized for 60 Hz rejection.

ENHANCED TIGER FAMILY MODELS DI-503

Triple Display Meters

L DI-602A Dual Display Meters

Digital Meter with Annunciators

L

Function

Function

POTENTIOMETER

L

INPUT MODULE SELECTION - CONTINUED

DI-50/AN6

L DI-802X Dual Line Alphanumeric LCD


Texmate Application-Specific Meters BN-SERIES 1/16 DIN (96 x 24 mm) SHORT-DEPTH METERS Standard 24 VDC isolated power supply, option 12V or 15 V. 0.56" std. red or optn. green or super bright red LED display.

Process 4 to 20 mA BN-35CL BN-35I BN-45I

BN-35 ............DC Volts Selectable from 2V/20V/200V, 3.5-Digit BN-45 ............DC Volts Selectable from 2V/20V/200V, 4.5-Digit

BCD Remote Display BN-35BCD BN-40BCD

AC Voltage

DU-35AC ........AC Volts, Average, 199.9/700.0 VAC DU-35ACRMSAC Volts, True RMS 199.9V/700V DU-40AC ........AC Volts, Average, 700.0 VAC, 4-Digit

Dual AC Volts and Hertz, Signal Powered DD-40VHZ........3.5-Digit, 0.3" LED Display

MU-SERIES 1/32 DIN (48 x 24 mm) METERS AC/DC auto sensing isolated power supply 12 to 24 VAC/9 to 36 VDC power supply. 0.3" standard red or optional green or super bright red LED display. MU-35 ............DC Volts Selectable from 2V/20V/200V MU-35MV ..........DC mV Selectable from 50 mV/100 mV/200 mV MU-35CL ..........Process 4 to 20 mA

UM-SERIES—NEMA CASE LOW-COST UTILITY METERS

AC Line Frequency DU-35HZ ..........Line Frequency 199.9 or 500 Hz up to 700V AC input w/3.5-Digit

DC Voltage

DU-35 ............DC Volts Selectable from 2V/20V/200V, 3.5-Digit DU-35MV ........DC mV Selectable 50 mV/100 mV/200 mV, 3.5-Digit DU-45 ............DC Volts Selectable from 2 V/20V/200V, 4.5-Digit DU-45MV ........DC mV Selectable 50 mV/100 mV/200 mV 4.5-Digit

Process 4 to 20 mA

DU-35CL ........Process 4 to 20 mA, 3.5-Digit DU-35CLE ........Process 4 to 20 mA with 24 VDC Excitation, 3.5-Digit DU-45CL ........Process 4 to 20 mA, 4.5-Digit

Pressure

DU-35P............Strain Gauge, Load Cell, and Pressure, 4- and 6-Wire, 5 VDC Excitation, Selectable Sensitivity from 2 mV to 20 mV/V, 3.5-Digit, 0.56" LED Display

Temperature DDU-35JC………..Thermocouple J, °C, 3.5-Digit DU-35JF……….….Thermocouple J, °F, 3.5-Digit DU-35KC………....Thermocouple K, °C, 3.5-Digit DU-35KF……….…Thermocouple K, °F, 3.5-Digit DU-35RTDC….…..100Ω Pt RTD, 2/3/4-wire, °C, 3.5-Digit DU-35RTDF………100Ω Pt RTD, 2/3/4-wire, °F, 3.5-Digit

Metal Case Option for 96 x 48mm DIN Case OP-MTL96X48 Provides Extra Strength and Protection Against Fire OP-MTLCLIP Mounting clips

......Remote BCD Display 3.5-Digit ......Remote BCD Display 4-Digit

Meter below, AC/DC auto sensing isolated power supply 85 to 256 VAC/90 to 380 VDC power supply. 0.3" standard red or optional green or super bright red LED display.

Standard user selectable 100/120 VAC or 200/240 VAC power supply, option 24 VAC, or auto sensing isolated AC/DC 9 to 24 VAC, 12 to 36 VDC. 0.56" std. red or optional green or super bright red LED display. DU-35AC1….……..AC Amps, Average, 1A (built-in shunt), 3.5-Digit DU-35AC5……….. AC Amps, Average, 5A (built-in shunt), 3.5-Digit DU-35ACI1RMS….AC Amps, RMS, 1A (built-in shunt), 3.5-Digit DU-35ACI5RMS…AC Amps, RMS, 5A (built-in shunt), 3.5-Digit DU-40AC1….……..AC Amps, Average, 1A (built-in shunt), 4-Digit DU-40AC5……….. AC Amps, Average, 5A (built-in shunt), 4-Digit DU-40ACI1RMS….AC Amps, RMS, 1A (built-in shunt), 4-Digit DU-40ACI5RMS…AC Amps, RMS, 5A (built-in shunt), 4-Digit

..........DC Volts Selectable from 2V/20V/200V, 3.5-Digit ..........DC Volts Selectable from 2V/20V/200V, 4.5-Digit

Meters below, 5 VDC power supply. 0.56" standard red or optional green or super bright red LED display.

DU-SERIES 1/8 DIN (96 x 48mm) METERS

AC Current

........Process 4 to 20 mA, 3.5-Digit

DC Voltage

DIGITAL METERS

31/2 Digit, 41/2 Digit and Bargraph Meters LED and LCD Displays Variety of NEMA & DIN Case Sizes Down to 1/32 DIN AC, DC or Loop Powered Measure DC Volts AC Volts DC Current AC Current Process mA Temperature (Thermocouple, RTD) Line Frequency RPM Pressure

L

• • • • •

Optional 0.8" display

Standard user selectable 100/120 VAC or 200/240V AC power supply, optn. 24 VAC, or auto sensing isolated AC/DC 9 to 24 VAC, 12 to 36 VDC. 0.56" std. red or optn. 0.8" std. red (3.5-digit and UM-40AC only) or green or super bright red LED display.

AC Current UM-35ACI ........AC Amps, Average, 1A or 5A, 3.5-Digit Display

AC Voltage

UM-35AC ........700 VAC and 199.9 VAC Full Scale, 3.5-Digit Display UM-40AC ........700.0 VAC FS, 0.1V Resolution, 4-Digit Display

AC Line Frequency UM-35HZ

........40 Hz to 199.9 Hz or 40 Hz to 500 Hz, 3.5-Digit

DC Voltage

UM-35............±2/20 VDC or Optionally ±2/200 VDC, 3.5-Digit UM-35MV ........±50 mV and ±00 mV Inputs to Suit External DC Current Shunts, 3.5-Digit UM-45............±2/20 VDC or Optionally ±2/200 VDC, 4.5-Digit UM-45MV ........±50 mV, ±100 mV, or ±200 mV Inputs to Suit Standard DC Current Shunts, 4.5-Digit

Process 4 to 20 mA UM-35CL

........1.4V Loop Drop, Scalable in Engineering Units from

-1999 to +1999, 3.5-Digit UM-35CLE ......Built-In 24 VDC Loop Excitation UM-45CL ........4.5-Digit Version of UM-35CL as Above

Pressure

UM-35P ..........For Pressure Transducers with 2 mV/V to 20 mV/V Outputs with 5 VDC Exc., 3.5-Digit

Thermocouple, 3.5-Digit

UM-35J ..........Designed for J Thermocouple Input, 1° Resolution UM-35K ..........Designed for K Thermocouple Input, 1° Resolution UM-35RTD ......3-Wire, 100-Ohm RTD, 0.1° or 1° Resolution

Continued on next page

18


Texmate Application-Specific Meters Continued from previous page

MINI-METER DVM-5 SERIES, 1.378 x 0.5 x 1.375" CASE Loop-Powered, Process 4 to 20 mA DVM-5/CL

............3.5-Digits, 0.276" LED Display

Volt and RTD, 5 VDC Power DVM-5 ................200 mV to 200 VDC, 0.276" LED Display DVM-5/RTD ..........RTD Sensor Input, 0.276" LED Display

SD-SERIES 1/8 DIN (96 x 48 mm) ULTRA SHORT-DEPTH Only 1.2" depth behind panel, including connectors.

DC Voltage SD-35 ............3.5-Digit, 0.56" standard red LEDs (optional green or super bright red). 2/20/200/Custom DCV ranges, 5VDC power. Pin compatible with Asahi AP-501.

4-20mA Loop Powered

SM SERIES 3-WIRE DC INPUT

SD-50X ..........5-Digit 0.5" LCD. 3.5-27.5mA input span, -19999 to 30000 count display. 6th digit displays F, C, inactive 0 or blank.

DIGITAL METERS

20 mV to 2 VDC, 3.5-Digit LED/LCD, 5 VDC Power SM-35 ............2 to 20 VDC, 0.56" LED, Display Hold SM-35X ............2 to 20 VDC, 0.48" LCD, Display Hold SM-35MV ..........20 mV to 2 VDC LED Constant Current 5 VDC Power Supply Eliminates Ground Loop Problems SM-35XMV ........20 mV to 2 VDC LCD Constant Current 5 VDC Power Supply Eliminates Ground Loop Problems

AM-SERIES 1/16 DIN (96 x 24 mm) SHORT-DEPTH BARGRAPHS 5 VDC power supply. 30 segment standard red or optional green or amber LED display.

SLIM-BEZEL CASE LED AND LCD MINIATURE METERS Loop-Powered, Process 4 to 20 mA, 0.48" LCD CM-35XTL ............Less than 1 VDC Loop Drop and 1 Joule Energy

Selectable Process 4 to 20 mA or DC Voltage AM-30 ............6 Header Selectable DC Ranges Plus 4 to 20 mA AM-30R1 ........6 DC + 4 to 20 mA w/One 2A/120 VAC Relay AM-30R2 ........6 DC + 4 to 20 mA w/Two 2A/120 VAC Relays

Storage. Fully Scalable CM-35XT

............Economical Standard 6.5V Loop Drop

DC and AC 2-Wire Signal-Powered, 0.48" LCD SP-35X ..............±3.5 VDC to 199.9 VDC SP-35XRMS ........AC or DC 15.0V to 199.9V and 15.0V to 250V SP-35XMV ..........50 mV shunt/10 to 100 VDC Power

Low Cost DC Bargraph, 5 VDC Power AM-20

..............20 Segment, 200 mV to 200 VDC, 5 VDC Power

DC Volts, 4.5 Digit LED/LCD, 5 VDC Power PM-45X/45XU ........200 mV to 1200V BCD Output Option PM-45L ..............200 mV to 1200 VDC and BCD Output Option

J and K Thermocouple Meters LED/LCD Differential Input Configuration Allows Several Meters to be Operated with Grounded Thermocouples from the same 5VDC Power Supply. TM35JC……….……Type J, °C, LED display TM35JF……….……Type J, °F, LED display TM35KC……….…..Type K, °C, LED display TM35KF……….…..Type K, °F, LED display TM35XJC……….….Type J, °C, LCD display TM35XJF……….….Type J, °F, LCD display TM35XKC……….…Type K, °C, LCD display TM35XKF……..……Type K, °F, LCD display

RP AND PM SERIES METERS DC Input, 110/230 VAC Power RP-35U ............Economy DC inputs, 3.5-Digit, 0.56" LED Display RP-35A ............Precision Differential DC Input, 3.5-Digit, 0.56" LED RP-35AR ..........Auto Dual Ranging, 3.5-Digit, 0.56" LED Display RP-3500 ..........Single Ended Input 3.5-Digit, 0.56" LED Display RP-3500D2 ......3.5-Digit Differential Input with Optional BCD RP-4500 ..........Single Ended Input 4.5-Digit, 0.56" LED Display RP-4500D2 ......4.5-Digit Differential Input with Optional BCD

DC Input, 5 VDC Power PM-35U ..........Low Cost, 3.5-Digit, 0.3" LED Display PM-35A ..........Differential Inputs, 3.5-Digit, 0.56" LED Display PM-35AR ..........Auto Range, 3.5-Digit, 0.56" LED Display PM-35X ..........Low Power, 3.5-Digit, 0.48" LCD Display PM-35XAC110 ..........DC Input 110/220 VAC Power, 0.48" LCD Display PM-45 ............Single Ended 4.5-Digit, 0.3" LED Display

19

LOOP POWERED LED BARGRAPH 1/16 DIN 96x24mm, 31 segment red or green LEDs. Only 4V loop drop, 3" behind panel. Available in horizontal or vertical orientation

SB-B31 ..............4-20mA Loop Powered Bargraph

SLIM BEZEL CASE COUNTERS & TOTALIZERS PC-45……..... 4.5-Digit, 5V DC Power, LED PC-45X…....… 4.5-Digit, 5V DC Power, 0.48" LCD PC-45XCA…...4.5-Digit, 110VAC Power, 0.48" LCD

TACHOMETERS & LINESPEED METERS 90-260VAC Powered, 72x36mm Case LT-30……......3-Digit, 0.8" LED Tachometer LT-40……...…4-Digit, 0.56" LED Tachometer LT-50……......5-Digit, 0.56" LED Tachometer LT-T30….......3-Digit, 0.8" LED Linespeed/Tachometer LT-T40………4-Digit, 0.56" LED Linespeed/Tachometer LT-T50……..5-Digit, 0.56" LED Linespeed/Tachometer

ACCESSORIES OP-N4X/96x48….NEMA-4X Clear, Lockable Dust & Waterproof Cover (for DU & SD series only) OP-PSA/96x48….NEMA-4X Panel to Case Seal Adapter PS-2405…………..120V AC Adapter, 24VDC @ 0.5A PS-520…………….120V AC Adapter, 5VDC @ 2A


Simpson Digital Meters/Controllers Includes new temperature measurement models (H340) • All Parameters Set from Front Panel • 7 Segment 4-1/2 or 3-1/2 Digit Bright Red Display • Screw Terminals for Easy Installation • 1/8 DIN Shallow Depth Case • Peak/Valley and Password Lockout • Optional Plug-In Output and Excitation Cards • Optional Plug-In Cards for One, Two or Four 5 Amp Relays

ORDERING INFORMATION

SPECIFICATIONS Display Type: Quantity: Height: Decimal Point:

7 segment, red LED H335: 3 1/2 digit; H345: 4 1/2 digit; H340: 4 digit 0.56" (14.2 mm) H335 and H340: 4-position, user programmable H345: 5- position, user programmable 5 Levels, user programmable 4 LED indicators for up to four set points

Brightness: Alarm Indicators: Power Requirements AC Voltages: 120, 85-250 VAC @ 10VA DC Voltages: 9–36 VDC @ 10 VA Accuracy @ 25°C: DC: H335: 0.1% of input ±1 digit H345: 0.05% of input ±1 digit AC: H335: 0.2% ±2 digits H345: 0.1% ±2 digits Sensor Type Accuracy Temperature Range RTD Pt 100 0.2% of input ±2 count -200°C to +200°C J 0.2% of input ±2 counts -100°C to +760°C K 0.2% of input ±2 counts -200°C to +1250°C E 0.2% of input ±2 counts -100°C to +800°C T 0.2% of input ±2 counts -200°C to +400°C Mechanical Bezel: 3.93 x 2.04 x .52" (98.8 x 51.8 x 13.2 mm) Depth: 3.24" (82.33mm) behind panel 1 Panel Cut-out: /8 DIN 3.62 x 1.77" (92 x 45 mm) Case Material: PBT-ABS Weight: 10 oz (283.5g) Temperature: 0-50°C Sample Rate: 10/sec

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: H335-1-46-0-1-2 A – B – C – D – E – F A B

C

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. A

– B – C – D –

E –

A

Basic Temperature Meter H340 4 digit Red LED

D

B

Power Supply 1 120V AC 3 9-36V DC 4 85-250V AC

E

Function Range 91 J Thermocouple 92 K Thermocouple 93 RTD, Pt100, 3-wire 94 E Thermocouple 95 T Thermocouple

F

C

F Analog Output 0 None 1 4-20 mA DC 2 0-10V DC 5 Amp Relays 0 None 1 One 2 Two 4 Four Excitation Output 0 None 1 12V DC (30mA max) 2 24V DC (30mA max)

D

E

F

Basic Panel Meter H335 31/2 digit Red LED H345 41/2 digit Red LED Power Supply 1 120VAC (31/2 digit only) 2 85-250 VAC (41/2 digit only) 3 9–36 VDC 4 85-250 VAC (31/2 digit only) Function/Range 11 200mV DC 51 12 2V DC 52 13 20 VDC 53 14 200V DC 54 15 600V DC 55

200mV AC TRMS 2V AC TRMS 20V AC TRMS 200V AC TRMS 600 AC TRMS

21 22 23 24 25 26

200µA DC 2m ADC 20mA DC 200mA DC 2A DC 5A DC

61 62 63 64 65 66

200µA AC TRMS 2mA AC TRMS 20mA AC TRMS 200mA AC TRMS 2A AC TRMS 5A AC TRMS

31 32 33 34 35

200mV AC 2V AC 20V AC 200V AC 600V AC

71 72

4-20mA DC Process 0-10V DC Process

81 82 83 84

200 Ohm 2k Ohm 20k Ohm 200k Ohm

41 200µA AC 42 2mA AC 43 20mA AC 44 200mA AC 45 2A AC 46 5A AC Output Signal 0 None 1 4–20 mA DC Process 2 0–10 VDC Process 6 RS-485 (4 1/2 digit only) 5 Amp Relay Outputs 0 None 1 One 2 Two 4 Four Excitation Output (not available with Signal Output) 0 None 1 12V DC (30mA max) 2 24 DC (30mA max)

20

DIGITAL METERS

L H345

• NEMA 4X Rated Front Panel


L

Simpson Digital Panel Meters

DIGITAL METERS

• Case Size: Standard 1/8 DIN • Accuracy: ±0.2% (F35); ±0.05% (F45DC); ±0.5% (F45AC) • Auto-Zero • Choice of AC or DC Power Supplies • Broad Range Scaling and Adjustable Zero Offset for Process Inputs • User-Selectable Decimal Points • Optional Excitation Output 12 VDC or 24 VDC • Easy Installation Using Screw Terminals

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number Order Example: F35-1-12-1

L

F35

M235

• Case Size: Standard 3/64 DIN Dimensions • Accuracy: ±0.5% (M235); ±0.5% (M245) • Minimum Depth Indicator—Less Than 2.5" (60 mm) of Space • User-Selectable Decimal Point • Optional Negative Image, Bright Red Backlighting • Standard Screw Terminals • 85V to 250 VAC Power or 9V to 32 VDC Mini-Max—3/64 DIN, 31⁄2 and 41⁄2 Digit AC and Process Indicators Simpson’s Mini-Max AC Voltage/Current Indicators provide high quality, accuracy, and reliability in a compact 60 mm deep case.

SPECIFICATIONS

A – B – C – D Basic Unit F35 31/2-Digit Meter F45 41/2-Digit Meter B Power Supply 1 120 VAC 2 220 VAC 3 9–32 VDC C Input Range C Input Range DC Voltage AC Voltage 200 mV 11 31 2V 12 32 20V 13 33 200V 14 34 DC Current AC Current 200 µA 21 41 2 mA 22 42 20 mA 23 43 200 mA 24 44 2A 25 45 5A 26 46 Process 71 4–20 mADC 72 1–5 VDC 73 0–10 VDC Temperature (F45 only) 80 J T/C 84 E 81 K T/C 85 R 82 S T/C 86 mV 83 T T/C 90 RTD Frequency RMS (F35) 20–199.9 Hz 91 93 20–1999 Hz 92 94 D Excitation Output (DC Input Only) 0 None 1 12 VDC 2 24 VDC

Power: Size:

A

85V–250 VAC @ 40 Hz–440 Hz; or 9V–32 VDC 2.84W x 0.95 x 2.36" WHD (72 x 24 x 60 mm)

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: M235-1-0-11-0 AC RMS 51 52 53 54 AC RMS (F35 Only) 61 62 63 64 65 66

T/C T/C DC PT 100 Sq. Wave (F35)

A – B – C – D – E A Basic Unit M235 31/2-Digit LCD Meter M245 41/2-Digit LCD Meter B Display 0 Non-Backlit 1 Negative Red Backlight C Supply Voltage 0 85–250 VAC 2 9–32 VDC* D Function Range 11 200 mVDC 31 200 mVAC TRMS 12 2 VDC 32 2 VAC TRMS 13 20 VDC 33 20 VAC TRMS 14 200 VDC 34 200 VAC TRMS 21 200 µADC 36 270 VAC TRMS 22 2 mADC 41 200 µAAC TRMS 23 20 mADC 42 2 mAAC TRMS 24 200 mADC 43 20 mAAC TRMS 25 2 ADC 44 200 mAAC TRMS 26 5 ADC 45 2 AAC TRMS 71 4–20 mADC 46 5 AAC TRMS 72 1–5 VDC 81 20–199.9 Hz 73 0–10 VDC 82 20–1999 Hz 74 0–100 VDC 83 20–199.9 Hz Sq. Wave 84 20–1999 Hz Sq. Wave E Excitation Output (NA with Frequency) 0 None 1 12 VDC 2 24 VDC

* Not Available on Frequency (Hz) Meters

21


Laurel High Performance DPMs FEATURES • ±99999 Display Span • User Selectable Ranges • 60 Readings Per Second • Adaptive Digital Filter • 1/8 DIN, NEMA-4X Front • 5, 10, 24V DC Excitation Out

OPTIONS (all outputs isolated) • Dual Setpoint Relay Outputs • Linearized Isolated Analog Transmitter Outputs • USB, RS-232 & RS-485 Data I/O • Custom Curve Linearization • Datalogging PC Software

Laureate™ DPMs offer exceptional accuracy at high reading rates. Advanced programming features provide flexibility in measuring DCV, ACV, DCA, ACA, temperature, weight, strain, process & pot follower.

ORDERING INFORMATION Example: L10010DCV1 K Laureate Series K Main Board

K Input Type DC Volts

SPECIFICATIONS Five 14.2 mm (.56”) high LED digits

< 0.01% FS ±1 ct < 0.01% FS ±1 ct < 0.1% FS (10 Hz-10 kHz) CF = 3.0 at full scale (AC or DC coupled) < 0.2°C < 0.1°C

Thermocouple RTD Noise Rejection CMR, DC to 60 Hz 130 dB NMR to 50/60Hz line 90 dB with min filtering Transducer Excitation Output (std) Output 100 mA @ 5V, 120 mA @ 10V, 50 mA @ 24V Dual Relay Output (opt) Contact relays . 8A @ 250 Vac or 24 Vdc Solid state relays 0.13A @ 140 Vac or 180 Vdc Linerarized Analog Output (opt) Level 0-20 mA, 4-20 mA, 0-10 Vdc, ±10 V Resolution 16 bits (0.0015%) Environmental Operating temperature 0 – 55°C, 95% RH at 40˚C, non-condensing Data Communications (opt) Type USB, RS-232, RS-485 (2- or 4-wire) Protocol Modbus RTU, Modbus ASCII or Laurel ASCII

DC Amperes

CBL01 CBL02 CBL05

RJ11 TO DB9 Cable to PC Com port USB to DB9 Adapter USB Cable to PC USB Port

85-264 Vac/90-370 Vdc 10-48Vdc/12-30 Vac None Dual 8 A relays Dual solid state relays None 0-20 mA & 0-10 V None RS-232 (Isolated) RS-485 (Isolated) RS485 Modbus (Isolated) USB USB to RS-485 Converter

DCV1 DCV2 DCV3 DCV4 DCV5 DCA1 DCA2 DCA3 DCA4

200.00 mV 2.0000 V 20.000 V 200.00 V 600.0 V 2.0000 mA 20.000 mA 200.00 mA 5.000 A

Process Signals (4-20 mA, 0-5 V, etc.)

P P1 Strain Gage, Potentiometer (4-wire ratio) SG SG1

4-20 mA = 0-10000 Custom Scaling 0-200 mV = 0-20000 Custom Scaling

Note: The same DC signal conditioner board can be user configured for DC Volts, DC Amps, process, or strain.

100-Ohm Platinum RTDs P385C P385F P392C P392F Thermocouples JC -210 to 760°C JF -347 to 1400°F KC -244 to 1372°C KF -408 to 2501°F TC -257 to 400°C TF -430 to 752°F EC -240 to 1000°C

-202 to 850°C -331 to 1562°F -202 to 850°C -331 to 1562°F EF NC NF SC SF RC RF

-400 to 1830°F -245 to 1300°C -410 to 2370°F -46 to 1768°C -51 to 3214°F -45 to 1768°C -49 to 3213°F

Note: The same temperature signal conditioner board can be user configured for all T/C and RTD types

TRMS Volts

TRMS Amperes

ACCESSORIES

0 1 0 1 2 0 1 0 1 2 4 5 6

DIGITAL METERS

K Setpoint Output

K Digital Interface

60/s at 60 Hz, 50/s at 50 Hz 3.5/s at 60 Hz, 3/s at 50 Hz

Laureate Panel Meter Laureate Weight Meter DPM with green LEDs DPM with red LEDs Extended, green LEDs Extended, red LEDs

Note: Extended capability for DPMs is required for custom curve linearization.

K Power

K Analog Output

Display A-to-D Conversion A-to-D rate Display update Accuracy at 25°C DC, Process Strain, Load True RMS

L LW 1 2 3 4

RMV1 RMV3 RMV5 RMV6 RMA1 RMA3

200.00 mV RMV2 2.0000 V 20.000 V RMV4 200.00 V 600.0 V (Not Agency Approved) 300.0 V 2.0000 mA RMA2 20.000 mA 200.00 mA RMA4 5.000 A

Note: The same AC RMS signal conditioner can be user-configured for AC Volts or Amps

Load Cells (6-wire ratio) WM1

-99,999 to +99,999

Note: Excitation is 10V DC for up to four 350Ω load cells in parallel

22


Selco Digital Panel Meters Universal Type • Seven Output Choices • Front Panel Membrane Set Buttons • Eighteen Input Choices • Available Two Setpoint Displays

DIGITAL METERS

• 90-264VAC or 9-60VDC Power Supply • RS-232C/RS-485 Communications • Industry Standard 1/8 DIN Size

L A5000 Series

• 8-Amp Setpoint Contact Relays

SPECIFICATIONS Main display: Sub display: Conversion rate: Maximum display: Overrange indication:

4 Digit Red LED 14.2mm Dual, Green LED 8mm (Hi & Lo setpoints) 12.5 times/sec 9999 When input exceeds the maximum display, display OL or -OL Zero display: Leading zero suppression Decimal point: Settable to any digit position External control: Start/Hold, Peak Hold, Digital Zero Operating temperature: 0 to 50°C, 35 to 85% RH Storage temperature: -10 to 70°C less than 60% RH Power supply: AC 100 to 240V ±10% (AC main unit) DC 9 to 60V (DC main unit) Power consumption: Approx. 4VA (at 100V) Dimensions: 96mm x 48mm (H) x 147.5mm (D) DIN size Dielectric strength (AC): Power supply/input terminal/output terminal 2000VAC/1 min. Input terminal/output terminal 500VDC/1 min. Case/power supply/input terminal/output terminal 2000VAC/1 min. Dielectric strength (DC): Power supply/input terminal/output terminal 500VDC/1 min. Input terminal/output terminal 500VDC/1 min. Case/power supply/input terminal/output terminal 2000VAC/1 min. Insulation resistance: 500VDC more than 100MΩ at the above terminals Input: AC Voltage: 40Hz to 1kHz AC Current: 40Hz to 1kHz Frequency: 0.1Hz to 200kHz 30V p-p Max. Strain Gauge: Adjustment Span: 1 to 3 mV/V Excitation: 5V@15mA, 10V@30mA Analog Output: 0-1V, 0-10V, 1-5V, 4-20mA Setpoint Relays: 8A@240VAC, 30VDC Resistive

23

ORDERING INFORMATION Example SE/A51/25-03 SE/A5

A

B

C

-

D

A

Main Board 1 AC 100 - 240V (±10%) 2 DC 9 - 60V B Display Board 1 Single (Main Display Only) 2 Multiple (Main & Sub Displays) C Output 0 None 1 HI & LO setpoint 2 Analog output 3 RS-232C 4 RS-485 5 HI & LO setpoint + analog output 6 HI & LO setpoint + analog output + RS-232C 7 HI & LO setpoint + analog output + RS-485 D Input 01 DC voltage (±99.99mV) 02 DC voltage (±999.9mV to ±600V) 03 DC current (±9.999mA to ±999.9mA) 04 AC voltage AVG (99.99mV to 9.999V) 05 AC voltage AVG (99.99V to 600V) 06 AC voltage RMS (99.99mV to 9.999V) 07 AC voltage RMS (99.99V to 600V) 08 AC current AVG (9.999mA to 999.9mA) 09 AC current AVG (5A) 10 AC current RMS (9.999mA to 999.9mA) 11 AC current RMS (5A) 12 Resistance (99.99Ω to 99.99KΩ) 13 Temperature (Thermocouple) 14 Temperature (RTD) 15 Frequency (Open collector, Logic, Magnet) 16 Frequency (50 to 500Vrms) 17 Strain gauge 18 1 to 5V, 4 to 20mA

Ranges 1 4 3 3 2 3 2 3 1 3 1 4 JKTSRB Pt100 4


Newport Panel Meters/Controllers INFCAC Series 4-Digit, 14-Segment LED Display, Red or Green High ±0.1% of Reading Accuracy Wide Selection of AC Current and Voltage Ranges Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Pending) • Front Panel Configuration • Available with Dual 6 Amp Relays and/or Analog Output

INFCAC

• • • •

INFC Series IDP-0

INFCAC ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: INFCAC-0-0-1-0-V5

IDP Series • • • • • •

A – B – C – D – E – F

Easy Scaling 4-Digit LED Display Max or Min Recall Short Case 4.1" (104 mm) Red or Green LED Display Power 115 VAC, 230 VAC or 10–32 VDC

INFC ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: INFCP-5-1-2 A – B – C – D

A

B

C

D

23a

Basic Unit INFCP Process (DC Voltage and Current) INFCS Strain Input NIFCT Thermocouple INFCDT Dual/Differential Thermocouple INFCR RTD INFCDR Dual/Differential RTD INFCPH pH INFCOR ORP INFCOP pH/ORP Power and Display 0 115 VAC, Red LED Display 1 230 VAC, Red LED Display 2 115 VAC, Green LED Display 3 230 VAC, Green LED Display 4 10–32 VDC, Red LED Display 5 10–32 VDC, Green LED Display 6 25–56 VDC, Red LED Display 7 25–56 VDC, Green LED Display Relays 0 None 1 Two 6 Amp Form C Relays Analog Output 0 None 1 Non-Isolated Analog 2 Isolated Analog Output

• Process (DC Voltage and Current), Strain Gauge, Thermocouple, and RTD • Dual Differential Thermocouple and RTD • pH ORP • Relay Output Optional • Isolated or Non-Isolated Analog Output Optional

A INFCAC B 0 1 2 3 C 0 1 D 0 1 E 0 1 2 F V5 C5

Basic Unit AC Voltage and Current Controller Power and LED Color 115 VAC, Red LED Display 230 VAC, Red LED Display 115 VAC, Green LED Display 230 VAC, Green LED Display Control Output No Control Output Two 6A Form “C” Relays$ Analog Output No Analog Output 4 to 20 mA or 0 to 10 VDC$ Communications No Serial Output Isolated RS-232 Isolated RS-485 Half Duplex$ Input Signal 0–750 VAC User Programmable 0–5 AAC User Programmable

$ N/C N/C N/C N/C 70 N/C 80 N/C $110 110 N/C N/C

IDP ORDERING INFORMATION N/C

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: IDP-0 A – B

A

B N/C $ 70 N/C $ 80 $ 90

Basic Unit IDP 4-Digit Process Meter IDT 4-Digit Thermocouple Meter IDpH 4-Digit pH Meter Display/Power 0 Red/115 VAC 1 Red/230 VAC 2 Green/115 VAC 3 Green/230 VAC 4 Red/10–32 VDC 5 Green/10–32 VDC

$195 $225 $245 N/C


Newport Digital Panel Meters/Controllers

i8

These meters accept universal inputs—thermocouple, RTD, process voltage/current. Panel mounted, with NEMA-4 (IP65) front bezel, they offer multiple “firsts” for 1/8 DIN instruments:

• Display Changes Colors at Set Point (Yellow, to Green, to Red) • Fully Programmable Color Display and the Largest Display (21 mm LEDs) of Any 1/8 DIN Instrument • RS-232 and RS-485 Serial Communications (Optional) in One Instrument • Built-In Excitation (10 or 24 VDC) is standard Units also feature ±0.5°C accuracy, free Active X Controls software, extended 5-year warranty at no extra charge. Available as monitors only or with two control/alarm outputs.

ORDERING INFORMATION

▲ INFU • 6-Digits • NEMA-4 (IP65) Front Bezel • Four Isolated Open Collector Outputs • Peak and Valley Detection and Memory • Digital Tare • 1.5 to 11 or 24 VDC Sensor Excitation

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: INFP-0-2-1-0-C2 A – B – C – D – E – F – G

A

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: i8-2-0-DC A – B – C – D

A

B

C

D

Base Units i800 Monitor only (no control outputs) 1/8 DIN $ 240 i8C00 Monitor only (no control outputs) 1/8 DIN Short Case *2$ i8A00 Monitor with Isolated Analog Output 1/8 DIN $ 295 i8 Two control outputs 1/8 DIN $ 310 i8C Two control outputs 1/8 DIN Short Case *2 $ 355 i8A Isolated Analog Output with two control outputs *1 365 Control Output #1 & #2 Direct (Cool) or Reverse (Heat) Acting 22 Two solid state relays (SSR’s) N/C 23 SSR and relay: Form “C” SPDT N/C 24 SSR and pulsed 10 Vdc(for use with external SSR) 33 2 Relays: Form “C” SPDT N/C 34 Relay and pulsed (for use with external SSR) N/C 44 Two pulsed 10 Vdc (for use with external SSR) N/C 52 Analog Output (control or retransmission) N/C 53 Analog Output and Relay N/C 54 Analog Outputand Pulse N/C Network Options E1 Ethernet with Embedded Web Server $ 55 C24 Isolated RS-232 and RS-485 (MODBUS & ASCII) $0 C4EI Ethernet with Embedded Internet + Isolated RS-485 $ Power Supply AC Standard Power : 90 to 240 VAC/DC N/C DC 10-34 Vac/dc (optional) $ 25

*1 Not Available for the i8A Controller *2 Not Available in the Compact Case

B C

D

E

F

G

Basic Unit INFP Process (DC Voltage and Current) $ INFS Strain Gauge $ DINFW Weight $ INFT Thermocouple and RTD $ INFU Universal Input (Process, Strain and Temp.) $ Split Display–Insert Only If Required Z Split Display (insert “Z” after INF in basic unit) Power and Display 0 115 VAC, Red LED 1 230 VAC, Red LED 2 115 VAC, Green LED 3 230 VAC, Green LED 4 10–32 VDC, Red LED $ 5 10–32 VDC, Green LED $ Control Output 0 Four NPN Open Collectors 1 Isolated Parallel BCD $ 2 Two 7A Relays $ 3 Two 7A Relays and Two 1A Relay $ Analog Output 0 None 1 Isolated Analog Output $ Serial Output 0 None 1 Isolated RS-232 $ 2 Isolated RS-485 $ Input Signal Specify T/C, RTD, or DCV

545 545 595 595 645 $ N/C N/C N/C N/C 110 110 N/C 110 75 175 N/C 110 N/C 110 110 N/C

23b


NEW

London Electronics Programmable Meter

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: INT2-P-0-0-232-R-AC INT2- A – B – C – D – E – F A

B

Intuitive 2 • 1/8 DIN, IP65 Front • Large 0.55" LED Display • Simplified Setup – No Menus • Display Filtering • 10-Point Custom Linearization • 0.05% Basic DC Accuracy • Variable Brightness Display

L

C D

®

E

Input types to match common sensors & process signals.

F

Crompton Digital Metering System Measure & Display • System (average) volts • System (average) current • System (total) kW • System volts (average) THD% • System current (average) THD% • Volts L1 – N, L2 – N, L3 – N • Volts L1 – L2, L2 – L3, L3 – L1 • Volts L1 – N THD% • Volts L2 – N THD%

L

• • • • • • • • •

Volts L3 – N THD% Volts L1 – L2 THD% Volts L2 – L3 THD% Volts L3 – L1 THD% Current L1, L2, L3 Current line 1 THD% Current line 2 THD% Current line 3 THD% Neutral current

SPECIFICATIONS 1630

• 35 Measured Parameters • 0.2% Basic Accuracy • Field Selectable CT & PT Ratios • Ethernet or RS-485 Interface • 1/4 DIN Case The Integra 1630 has Modbus communication and field selectable system configuration: single-phase, three-phase threewire or three-phase four-wire.

Measur ing Ranges Voltage: 80-120% of nominal (functional 5-120%) Current: 5-120% of nominal Frequency: 45-66Hz Power Factor: 0.8 capacitive to 0.8 inductive THD: Up to 31st harmonic 0% - 40% Energy: 7 digit resolution Input PT Ratio (primary): up to 400kV ** CT Ratio: 9999:5A ** Outputs RS-485: Half duplex (2-wire) Baud rates: 4800, 9600, 19200, 38400 Pulsed: 1 or 2 Solid state relays Pulse duration: 60, 100 or 200 milliseconds Contact rating: 50mA max at 250V AC max. Auxiliar y Suppl y AC/DC supply: 85–287VAC, 85–312VDC, 45–66Hz DC supply: 10.2–60VDC Burden: 6VA ** 360MW max at 120% of relevant input

• • • • • • • • • •

Frequency Power factor (overall) kVAr, kVA, kW kW Hr import, export (7 digits) kVArh import, export (7 digits) kW demand Current demand Maximum kW demand Maximum current demand Hours run

ORDERING INFORMATION INT-1630 –Example INT-1630-M-5-M-110

A – B – C – D A

B

C

D

Input Voltage L 57.7-139 L-N (100-240 L-L) M 140-277 L-N (241-480 L-L) Input Current (CT secondary) 5 5A 1 1A Auxiliary Voltage L 12-48 V DC M 100–250V AC/DC Options 000 None 010 RS-485 Modbus RTU 100 One Pulse 200 Two Pulse 210 Two Pulse & Modbus 110 One Pulse & Modbus 070 Ethernet Modbus TCP

24

DIGITAL METERS

Input Type P DC Process: 0-10V, 1-5V, 0-10mA, 4-20mA M Millivolt Input for use with DC shunts T Temperature: J K T R S N & Pt100, °F & °C R 4-Wire Resistance: specify range to 20kΩ L Load Cell: 4/6-wire, w/ 10V excitation I Flow Integrator: 0-10V, 4-20mA H Clock/Timer, numeric or HH:MM:SS display C Counter/Frequency/RPM/Quadrature S Remote Display, serial ASCII data input Analog Output (Isolated) 0 None ANV 0–10V ANI 4–20 mA ANB -10 to +10V Relay Output (2A@250 VAC) 0 None AL4 4 Form A AL2 2 Form A SPCO 2 Form C Serial Data Output 0 None 232 RS-232 MB RS-485 ModBus RTU 485 RS-485, ASCII EN Ethernet Display Color R Red Y Yellow G Green Supply Voltage AC 100-240 VAC DC 11–30 VDC


Crompton Digital Metering Systems Integra 510

Integra 640

• 3 Line 4 Digit LCD Display • Self or Externally Powered • Programmable CT Ratios (1-8000A) • Setup Password Protection • IP54 Front Integra 510

• • • • • •

Display Voltage, Current & Frequency True RMS Measurement Fully Programmable PT and CT Ratios Simple Menu Driven Interface ANSI Case Bright LED Display

DIGITAL METERS

L

Integra 640

Display up to 12 electrical parameters on 4 screens:

Display up to 12 electrical parameters on 4 screens:

1 Current L1 Current L2 Current L3

3 Volts L1 – L2 Volts L2 – L3 Volts L3 – L1

1 System Volts System Current System Frequency

3 Volts L1 – L2 Volts L2 – L3 Volts L3 – L1

2 Volts L1 – N (4 wire only) Volts L2 – N (4 wire only) Volts L3 – N (4 wire only)

4 System Volts System Current System Frequency

2 Volts L1 – N (4 wire only) Volts L2 – N (4 wire only) Volts L3 – N (4 wire only)

4 Current L1 Current L2 Current L3

SPECIFICATIONS Max Input Voltage: Input Voltage Burden: Max Input Current: Input Current Burden: Auxiliary Supply Tolerance: Frequency Range: AC Supply Burden: Measuring Range Voltage (Self Powered): Voltage (Aux. Powered): Line-Line Voltage, 4 Wire: Current: Frequency Range: Accuracy Voltage: Current: Frequency: Operating Temperature: Storage Temperature: Enclosure: Terminals: Compliance: Dimensions: Panel Cut Out:

120% of nominal continuous, 2x for 1 sec. 0.2 VA per line, nominal 120% of nominal continuous, 20x for 1 sec. 0.6 VA per phase, nominal -10%, +20% of nominal range 45 - 66Hz 3VA 75 - 125% of nominal 2.5 -120% of nominal 0 - 10% difference in phase voltage 2.5 - 120% of nominal 45 - 66Hz 1.5% of nominal 1.5% of nominal 0.5% of mid frequency -10 to +70°C, <95% RH non-condensing -20 to +80°C Polycarbonate UL94V-0/V-2 M3.5 captive screw clamp UL3111-1, IEC1010-1 CAT III, IEC688:1992 96mm x 96mm x 112mm deep 92mm x 92mm (3.62" x 3.62")

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: CR/244-513W-10LS-10 A – B – C

A

Basic Unit CR/244-513W 3 phase 3 wire CR/244-514W 3 phase 4 wire B Measured Input Range 10LA 100-120V L-L (58-69V L-N), 1A CT 19LA 190-240V L-L (110-139V L-N), 1A CT 38LA 380-480V L-L (219-277V L-N), 1A CT 10LS 100-120V L-L (58-69V L-N), 5A CT 19LS 190-240V L-L (110-139V L-N), 5A CT 38LS 380-480V L-L (219-277V L-N), 5A CT C Auxiliary Supply SP Self powered 10 100 – 120V AC 19 190 – 240V AC 38 380 – 480V AC

25

L

SPECIFICATIONS Max Input Voltage: Input Voltage Burden: Max Input Current: Input Current Burden: System PT (primary): System CT: Auxiliary Supply AC Supply:

120% of nominal continuous, 2x for 1 sec. 0.2 VA per line, nominal 120% of nominal continuous, 20x for 1 sec. 0.6 VA per phase, nominal 400kV or 360MW max 9999:5A or 360MW max 100 – 250V AC or DC nominal (85 – 287V AC Absolute) (85 – 312V DC Absolute) 45 – 66 Hz 12 - 48V DC (10.2 – 60V DC Absolute) 6VA

Frequency Range: DC Supply: Supply Burden: Measuring Ranges Voltage: Current: Frequency: Accuracy Voltage: Current: Frequency: Operating Temperature: Storage Temperature: Enclosure: Terminals: Compliance: Dimensions: Panel Cut Out:

70 - 120% of nominal (functional 4 - 120%) 5 - 120% of nominal 45 - 66Hz ±0.1% of range ±0.4% of reading ±0.1% of range ±0.4% of reading 0.15% of mid frequency -20 to +70°C, <95% RH non-condensing -30 to +80°C Polycarbonate front and base, steel case Barrier terminal strip, 6-32 screw UL140758, IEC 1010, IP54 (front face) 4.31" high x 4.31" wide x 6.7" deep 4.06" (103mm) diameter, 4 stud positions

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: CR/INT-0643-MIV-5-L A – B – C – D

A B

C D

Basic Unit CR/INT–0644 CR/INT–0643 Input Voltage ELV LOV MIV HIV Input Current 5 Auxiliary Supply 10 19

Integra 0640, 3 phase 4 wire Integra 0640, 3 phase 3 wire 100 - 120 V L-L (57.7 - 69.3V L-N) 121 - 240 V L-L (70.1 - 139V L-N) 241 - 480 V L-L (140 - 277V L-N) 481 - 600 V L-L (278 - 346V L-N) 5A CT input 100 – 120V AC 190 – 240V AC


Electro Industries Power Meter L

Shark

SPECIFICATIONS System: Voltage Input: Max. Burden: Current Withstand: Max. Burden: Pass-thru Wire: Isolation: Operating Temp: Sampling: Update Rate: Power Supply: Communications: Protocol: Dimensions, Ratings:

3 Element Y, 2.5 Element Y, 2 Element ∆, 4 Wire ∆ 0-416VAC L-N, 0-721VAC L-L 0.36VA per phase at 600V, 0.014VA at 120V 100A for 10sec, 300A for 3sec, 500A for 1sec 0.005VA per phase at 11A 0.177" (4.5mm) max dia. All Inputs and Outputs are galvanically isolated to 2500VAC -30 to +70°C, <95% RH non-condensing 400+ Samples/Cycle, all channels measured simultaneously 1sec, except 100msec on Watts, VAr, VA 90-265VAC / 100-37-VDC, 10VA RS485 Port (rear), IrDA (faceplate) Modbus RTU, ASCII or DNP 3.0 4.85"H x 4.82"W x 4.25"D, NEMA12 FACE

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: EI/Shark100-60-10-V2-485-X EI/SHARK A – B – C A

– D – E – F

Model* 100 Power Meter/Transducer with LED Display 200 Advanced Power Meter/Transducer B Frequency 50 50Hz 60 60Hz C Current Input Class 10 0-11A (5A nominal) 2 0-2A (1A nominal) D Functions V1 Volts/Amps V2 V1 + Power & Frequency V3 V2 + Energy Counters, DNP3.0 V4 V3 + Harmonics & Limits E Communications X None 485 RS-485 F Mounting X ANSI DIN DIN mounting brackets * Add suffix T for Transducer only (DIN mount) without display

GIMA

G100 G200

Parameter Phase Amps Phase Volts Line Volts Per phase PF Per phase kW Per phase kvar Per phase kVA 3 Phase PF 3 Phase kW 3 Phase kvar 3 Phase kva Frequency kWh Capacitive kvarh Inductive kvarh Total kvarh Import kVah Current Demand Voltage Demand kW Demand Peak Amps Peak Phase Volts Peak Current Demand Peak Voltage Demand Neutral Current

G300

• • • • •

• • • • •

• • • • • •

• •

• •

• • •

• •

• • • • •

• •

• •

• • •

• •

• •

• •

G400 • • • • • • • • • • • • • • • • • • • • • • •

DIGITAL METERS

Parameter Accuracy Display Voltage L-L & L-N: 0.1% 0-9999 V or kV, scalable Current: 0.1% 0-9999 Amps or kAmps ± Watts 0.2% 0-9999 Watts, kWatts, MWatts ±Wh 0.2% 5 to 8 Digits Programmable ±VARs 0.2% 0-9999 VARs, kVARs, MVARs ±VARh 0.2% 5 to 8 Digits Programmable VA 0.2% 0-9999 VA, kVA, MVA VAh 0.2% 5 to 8 Digits Programmable PF 0.2% ±0.5 to 1.0 Frequency 0.01 Hz 45 to 65 Hz %THD 1.0% 0 to 100% % Load Bar 1-120% 10 Digit Resolution Scalable Real time measurements for all parameters; plus Min/Max for V, A, W, VAr, VA, PF, f, %THD: Average for A, W, VAr, VA, PF

• Measure up to 23 Parameters • Standard 1/4 DIN Case • Wide Backlit LCD Display • Four Keys Select All Parameters • Software Detection/Correction of Wiring Errors

L

• Multifunction TRMS Measurements • Meets ANSI C12.20 and IEC 687 0.2% Accuracy Class • Bright 0.56" 3 Line LED Display • % of Load Bar for Analog Perception • Programmable CT & PT Ratios • Modbus and DNP Protocol • RS-485, Ethernet or fiber communication

Simpson Digital Power Meters

SPECIFICATIONS System: Input Frequency: Harmonics: Operating Temperature: Accuracy:

3 phase, 3 or 4 wire, unbalanced load 0.5% to 120% of range 45-65Hz

up to 20th harmonic -10°C to 65°C, <75% RH Current: ±0.2% of full scale Voltage: ±0.3% of full scale Watts: ±0.4% of full scale

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: SI/G100–1–3–1–0 A – B – C – D – E A Basic Unit SI/G100 GIMA 100 Meter SI/G200 GIMA 200 Meter SI/G300 GIMA 300 Meter SI/6400 GIMA 400 Meter B Power 1 115VAC 2 230VAC C Voltage Input 1 120/208V 2 120/240V 3 277/480V 4 63/110V D Current Input 1 5 Amp E Other 0 None 1 ModBus Communication

26


Yokogawa AC Switchboard Meters

2493

L DIGITAL METERS

DIGITAL METERS

Single, dual, and triple displays • Field Configurable • Measures True RMS Current and Voltage • Accuracy: ±0.2% of Rdg. ±0.1% FS • Displays MIN/MAX Values • Scaling to 1250:1 for Potential Transformers, 5000:1 for Current Transformers • Available for Single- and Three-Phase Systems • High-Resolution, High-Intensity LED Display • Fits Standard Panel Cutouts • Non-Volatile Memory Stores All Setup Parameters • Options Include RS-485 Communications, Analog Outputs, DC Auxiliary Power Supply

AC WATT/VAR SINGLE FUNCTION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 2491-53-11-5-AHF-0 A – B – C – D – E – F A B

D

E

F

27

L 2491

L

C

2491 Single Function Function Connection 51 Watt 1P2W 52 Watt 1P3W 53 Watt 3P3W 54 Watt 3P4W (21/2 Element) 55 Watt 3P4W (3 Element) 61 Vars 1P2W 62 Vars 1P3W 63 Vars 3P3W 64 Vars 3P4W (21/2 Element) 65 Vars 3P4W (3 Element) 71 Power Factor 1P2W 72 Power Factor 1P3W 73 Power Factor 3P3W 74 Power Factor 3P4W (21/2 Element) 75 Power Factor 3P4W (3 Element) 91 Phase Angle 1P2W 92 Phase Angle 1P3W 93 Phase Angle 3P3W 94 Phase Angle 3P4W (21/2 Element) 95 Phase Angle 3P4W (3 Element) AC Input Rating 11 120 Volt/1 Amp 15 120 Volt/5 Amp 21 240 Volt/1 Amp 25 240 Volt/5 Amp 33 Special (Describe) Frequency 5 50/60 Hz 6 400 Hz 8 Special Calibration Analog Output AAA None AFA 0 to 1 mA AFB 0 to ±1 mA AHD 4 to 20 mA AHF 12 ±8 mA Communication 0 None 1 RS-485

2492

AC AMP/VOLT/FREQUENCY SINGLE FUNCTION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 2491-21-1-AHD-0 A – B – C – D – E A B

C

D

E

2491 Single Function Input Range 11 1 Amp AC 15 5 Amp AC 21 150 Volts AC 25 300 Volts AC 81 Frequency (150V) 83 Frequency (300V) Frequency 1 50/60 Hz 2 400 Hz 3 Special Calibration Analog Output AAA None AFA 0 to 1 mA AFB 0 to ±1 mA AHD 4 to 20 mA AHF 12 ±8 mA Communication 0 None 1 RS-485


Yokogawa AC Switchboard Meters

AC VOLT AND VOLT/FREQUENCY To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 2492-16-1-AHD-0-1 A – B – C – D – E – F

AC VOLT OR AMP To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 2493-03-1-AFA-0-1

A B

A – B – C – D – E – F A B

D

E F

C D

E F

DIGITAL METERS

C

2493 Triple Display Connections/Input Rating 01 3P3W 150 VAC 02 3P4W 150 VAC 03 3P3W 300 VAC 04 3P4W 300 VAC 05 3-Phase A, B, C 1 AAC 06 3-Phase A, B, C 5 AAC Frequency 1 50/60 Hz 2 400 Hz Analog Output AAA None AFA 0 to 1 mA DC AHD 4 to 20 mA DC Communication 0 None 1 RS-485 Auxiliary Power 1 120 VAC 2 240 VAC 3 24 VDC 4 48 VDC 5 125 VDC

2492 Dual Display Function Connection 12 150 Volt/1 Amp AC 13 300 Volt/1 Amp AC 16 150 Volt/5 Amp AC 17 300 Volt/5 Amp AC 22 150 Volt and 50/60 Hz 23 300 Volt and 50/60 Hz 26 150 Volt and 400 Hz 27 300 Volt and 400 Hz Frequency (NA For Frequency Units) 1 50/60 Hz 2 400 Hz Analog Output AAA None AFA 0 to 1 mA AHD 4 to 20 mA Communication 0 None 1 RS-485 Auxiliary Power Supply 1 120 Volt 50/60 Hz 2 240 Volt 50/60 Hz

AC WATT/VAR/POWER FACTOR To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 249247-13-5-AFA-0-1 A – B – C – D – E – F – G

AC VOLT/AMP/HERTZ To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 2493-08-1-1-AHD-0-1 A – B – C – D – E – F – G A B

C

D E

F G

2493 Triple Display Function/Connections 07 Volt/Amp/Hz 1P2W 08 Volt/Amp/Hz 3P3W 09 Volt/Amp/Hz 3P4W Volt/Amp Rating 1 150V/1 AAC 2 150V/5 AAC 3 300V/1 AAC 4 300V/5 AAC Frequency 1 50/60 Hz 2 400 Hz Analog Output AAA None AFA 0 to 1 mA DC AHD 4 to 20 mA DC Communication 0 None 1 RS-485 Auxiliary Power 1 120 VAC 2 240 VAC 3 24 VDC 4 48 VDC 5 125 VDC

A 2492 Dual Display 2493 B Function/Connection 40 Watt/VAR 1P2W 34 41 Watt/VAR 1P3W 35 42 Watt/VAR 3P3W 36 43 Watt/VAR 3P4W (21/2 Element) 37 44 Watt/VAR 3P4W (3 Element) 38 45 Watt/PF 1P2W 46 Watt/PF 1P3W 47 Watt/PF 3P3W 48 Watt/PF 3P4W (21/2 Element) 49 Watt/PF 3P4W (3 Element) C AC Input Rating 12 120 Volt/1 Amp 1 13 120 Volt/5 Amp 2 16 240 Volt/1 Amp 3 17 240 Volt/5 Amp 4 D Frequency 5 50/60 Hz 1 6 400 Hz 2 E Analog Output AAA None AFA 0 to 1 mA AFB 0 to ±1 mA AHD 4 to 20 mA AHF 12 ±8 mA (Dual display only) F Communication 0 None 1 RS-485 G Aux. Power Supply* 1 120 Volt 50/60 Hz 2 240 Volt 50/60 Hz

Triple Display Watt/VAR/PF 1P2W Watt/VAR/PF 1P3W Watt/VAR/PF 3P3W Watt/VAR/PF 3P4W (21/2 Element) Watt/VAR/PF 3P4W (3 Element)

120 Volt/1 Amp 120 Volt/5 Amp 240 Volt/1 Amp 240 Volt/5 Amp 50/60Hz 400Hz

* DC Power available on Triple Display meters

28


• Multiple Measured Parameters – Power and Energy (Active, Regenerative, Reactive, Apparent) plus Voltage, Current, Frequency, Power Factor and Demand • Selectable System Configurations – Single and Three Phase; Two, Three and Four Wire • Selectable Input Voltage Range – 120V, 240V, 480V • CT & PT Ratios Entered from the Front Panel • Standard RS-485 and Optional Ethernet Communications with Modbus Protocol • Analog and Pulse Outputs • Digital Input for Integration Start/Stop or Demand Alarm Release • ANSI 4" Round or DIN 96 Square Mounting A single unit replaces up to 11 analog meters, contributing to savings on cost, space and wiring.

Eight display screens are available on the PR300. The three parameters displayed in each screen are user selectable.

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: PR300-42203-6A-0 B C D E - F G - 0 PR300 - A A

B

C

D

E

F G

Basic Unit 3 Universal three-wire system (single-phase twowire, single-phase three-wire, three-phase three wire) 4 Universal four-wire system (single-phase two-wire, single-phase three-wire, three-phase three-wire, three-phase four-wire) 5 Three-phase four-wire (2.5 element) Input 1 Universal voltage (150/300/600V), 1A AC 2 Universal voltage (150/300/600V), 5A AC Additional Inputs & Outputs 0 1 digital input 1 1 digital input, 1 analog output 2 1 digital input, 1 pulse output 3 1 digital input, 1 analog input, 1 pulse output Communications 0 RS-485 (PC Link, Modbus ASCII & Modbus RTU protocols) 3 Ethernet (Modbus TCP protocol)* Optional Measuring Functions 0 None 3 Demand measurement (1 demand alarm output) Power Supply 6 100-240V AC (50/60Hz) or 130-300V DC Phase Indication A A, B, C R R, S, T

*Ethernet includes RS-485 for communication to other PR300 meters

29

L

DIGITAL METERS

Yokogawa Power and Energy Meters

PR300 POWERCERT

SPECIFICATIONS Accuracy:

Active energy ±0.5% Active power ±0.5% of FS Voltage, Current ±0.25% of FS Frequency ±0.5Hz Demand ±0.5% Max. Input Voltage: 150V, 300V, 600V Max. Input Current: 1.2X FS continuous, 2X for 10s, 10X for 3s Frequency: 45 to 65 Hz Digital Input: On level: 4.5-25V DC, Off level: within ±1VDC Demand Function: Average power or average current Demand Period: 1 to 60 minutes Analog Output: 4-20mA DC Load: <600Ω Measured Item: Active power, reactive power, apparent power, phase voltage, phase current, power factor or frequency Pulse Output: Pulse proportional to energy Measured Item: Active energy, regenerative energy, reactive energy (Lead/Lag) or apparent energy Units: 0.1 to 5000.0 kWh/pulse; set in 100Wh increments Signal: Open collector, 30V DC @ 200mA max. Alarm Output: Alarms when measured demand exceeds setpoint Signal: Open collector, 30V DC @ 200mA max. RS-485: 2-wire (half-duplex) Address: 01 to 99 (31 units max.) Buad Rate: 19200, 9600 & 2400 bps Protocol: PC Link (with or without checksum), Modbus (RTU, ASCII) Ethernet: IEEE802.3 compliant 10Base-T/100Base-TX IP Address: Set from front panel. Only one address required for each PR300 cluster. Gateway: RS-485 port on Ethernet meter communicates with RS-485 port on other PR300 meters Data Backup: Last integrated value of active energy, regenerative energy, reactive energy & apparent energy are stored in non-volatile memory Withstand Voltage: 2500V AC between V & A inputs, power and ground; 2500V AC from V & A inputs, power and ground to digital input, pulse output, analog output, communications port and alarm output Operating Temp.: 0 to 50°C, 20-90% RH non-condensing Temperature Effect: 0.01%/°C Display: Three 5-digit LEDs with unit & function annunciators Power: 100-240VAC ±10% (50/60Hz) , 130-300V DC ±15% Power Consumption: 10VA, 5W max. Case: Polycarbonate UL94-V0 Connections: Screw terminals (except Ethernet) Size: ANSI: 4.33" x 4.33" x 5.05" (110 x 110 x 128 mm) DIN: 96 x 96 x 126 mm


Electro Industries Multi-Function Power Monitor ▲

• Built-in Ethernet Connectivity (DMMS-350) • ANSI Footprint • True RMS .2% Accuracy (DMMS-300) • .3% Accuracy (DMMS-425) • Harmonic Distortion to 31st Order • Harmonic Waveform Capture (DMMS-300) • MIN/MAX Demand • 10 Channels of Analog Transducer Output • ModBus, DNP 3.0 • Utility Grade

DMMS-425

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: DMMS-300-R-2E-X-KV-KA-MW-120-115A-MODR-X A – B – C – D – E – F – G – H – I – J – K – L

A Basic Unit DMMS-300 Multi-Function Power Monitor DMMS-350 Multi-Function Power Monitor DMMS-425 Multi-Function Power Monitor B Reading Type (N/A for DMMS-425) X KVAH Reading R KVARH Reading C Connection 3E 3 Element–3-Phase 4-Wire Wye (3 PTs) 2.5E 2.5 Element–3-Phase 4-Wire Wye (2 PTs) 2E 2 Element–3-Phase 3-Wire Delta D Harmonic Capability (N/A for DMMS-425) X None H Harmonics to 31st Order E Volts Label V Volts Label KV Kilovolts Label F Amps Label A Amps Label KA Kiloamps Label G Power Label KW Kilowatts Label MW Megawatts Label H Operation Monitoring Voltage 120 120/208V (Direct Reading or PTs) G 277/480 (Direct Reading) I Operating Power 115A 115 VAC ±20%, 6 VA 230A 230 VAC ±20%, 6 VA D 24–48 VDC ±20%, 6 VA D2 125 VAC or DC ±20%, 6 VA Universal D4 12 VDC ±20%, 6 VA J COM Protocol MODR ModBus RTU MODA ModBus ASCII DNP DNP 3.0 EI EI-Bus K Relay Options X None NL 2 Relays–1 KYZ Pulse (DMMS-300 only) NL2 3 KYZ Pulses L Output Module Option SF485DB RS485 Output (Digital) SF532DB RS232 Output (Digital) SHNI-1 10 Channel 0-1mA (DMMS 300 only) SHNI-20 10 Channel 4-20mA (DMMS 300 only)

49

ORDERING INFORMATION

DMMS-300

The DMMS-300 is a four-quadrant multi-function power meter that measures: • • • •

3Ø Voltage (L-N, L-L) 3Ø Current Neutral Current Bi-directional KW (3Ø & Total)

• Bi-directional KVAR (3Ø & Total) • KVA (3Ø & Total) • PF (3Ø & Total) • Bi-directional KWh

• • • •

KVAh Frequency %THD K Factor

It replaces individual single-function meters by providing three parameter displays and an easy to use front panel interface, as well as digital and analog connections to a control or monitoring system. The DMMS-300 includes advanced power measurements and min/max storage for power analysis & control. User-defined setpoints are available for most measured values. The DMMS-350 adds a standard Ethernet TCP/IP connection. The meter is ideal for applications requiring real time metering or data streaming to a LAN or through the Internet. Information is reported using the industry standard Modbus TCP/IP protocol. Harmonic measurements are also standard in the DMMS-350. The DMMS-425 is an economical power monitor that measures and calculates over 80 electrical parameters, including maximum and minimum values for every reading. This full four-quadrant meter has separate positive and negative Watthour counters and complies with ANSI C12 revenue metering accuracy requirements.

SPECIFICATIONS Accuracy Volts: Amperes: KW: KVA: KVAR: PF: KW Hour: KVA Hour: KVAR Hour: Frequency: Harmonics: Input Voltage:

DMMS-300 DMMS-350 DMMS-425 0.2% of Full Scale 0.2% 0.3% 0.2% of Full Scale 0.2% 0.3% 0.4% of Full Scale 0.4% 0.6% 0.4% of Full Scale 0.4% 0.6% 0.4% of Full Scale 0.4% 0.6% 1.0% of Full Scale 0.4% 0.6% 0.4% of Full Scale 0.4% 0.6% 0.4% of Full Scale 0.4% 0.6% 0.4% of Full Scale 0.4% 0.6% 0.02 Hz 0.02 Hz 0.02 Hz 0.50% 0.50% NA 150V phase to neutral, 300V phase to phase–std. 300V phase to neutral, 600V phase to phase–G option 300V phase to neutral, 150V phase to phase–75 option Input Current: 5A at Full Scale, 10A maximum Burden: Voltage 0.1 VA maximum; Current 0.1 VA maximum Operating Temp.:-20°C to +70°C Sensing Method:True RMS sampling at 64 samples per cycle

29a


Electro Industries Utility Billing Meter • • • • • • • •

0.6% W/Hr Revenue Meter 20 Year Time of Use Loss Compensation Power Quality Data Logging & Event Recording Multiple Communication Paths Modbus, DNP3, Ethernet, Web Graphical LCD Display

• Normal Mode, Time of Use Mode, Diagnostic Mode • Two Historic Logs, Multiple Demand Windows • CBEMA/ITIC Log (Model 1270) • Setup Parameters Stored in Non-Volatile Memory • Dial Out on Alarm or Event

ORDERING INFORMATION To Order–Insert Number Code for Each Letter to Select Catalog Number. A – B – C – D – E – F – G

A

NEXUS 1270

B

SPECIFICATIONS Accuracy: Voltage Current Frequency kWh @1.0PF kWh @0.5PF kVAR kVA PF Sensing:

0.02% 0.05% 0.001Hz 0.06% 0.1% 0.1% 0.1% 0.1% 16 bit A/D inputs True RMS measurements 8 channel sample & hold Digital Inputs: 8 channels, self excited, dry contact Solid State Outputs (KYZ): 4 channels, form C, 350VDC/120mA Timing: Internal clock accurate to 1 min/month IRIG-B input for sync to external GPS signal Standard Communications: IR port Two RS-485 serial ports Modbus RTU, Modus ASCII, DNP3.0 protocols Data Speeds to 115kbps Eight high speed input channels Optional Communications: Internal modems with data buffering Internal Ethernet with multiple socket support & Modbus TCP/IP Operating Temperature: -40°C to 85°C Security: Hardware & Password Locks Standard Power (S): 96-550VAC 50/60Hz auto-ranging meter power from any of the 3 phases. External Power (SE): 96-275VAC 50/60Hz or 125VDC ±20% Dimensions: S case 6.96" dia x 6.0"deep SWB case 6.813"W x 9.188"H x 9.30"D Memory: Model Log1 Log2 CBEMA Event Waveform Output Input 1260S 80 days 32 days 1024 512 512 1260A 691 days 132 days 1024 512 512 1270S 97 days 132 days 1024 1024 64 512 512 1270A 602 days 132 days 1024 1024 96 512 512

51

C

D E F

G

Model 1260 1270

Nexus Utility Billing Meter Nexus Utility Billing Meter with Advanced Power Quality

Memory S A Form 9S 35S 36S SWB Class 02 020 Frequency 60HZ 50HZ Power Supply S SE DE LV Internal I/O X INP2 INP10 INP100 4IPO

Standard Advanced 120-277V L-N; 3E, 4W, Wye 120-480V L-N; 2E, 3W, Delta 120-277V L-N; 2 1/2 E, 4W, Wye 120-277V L-N; programmable (Amps) Class 2 (0 to 2 A ) Class 20 (0 to 20 A)

Standard Std External 18-60V DC 69V AC ±20% None Dial out Modem 10Mb Ethernet 10/100 Base T 4 Pulse Output Relays

EXTERNAL OPTIONAL MODULES External Modules EI/1MAON4 EI/20MAON4 EI/1MAON8 EI20MAON8 EI/8AI1 EI/8AI2 EI/8AI3 EI/8AI4 4RO1 4PO1 8DI1 MBIO PSIO Software NXDS1.0C AIREPORTS1

4 Channel Analog Outputs, 0-1mA 4 Channel Analog Outputs, 4-20mA 8 Channel Analog Outputs, 0-1mA 8 Channel Anaolgo Output, 4-20mA 8 Channel Analog Input, 0-1mA 8 Channel Analog Input, 4-20mA 8 Channel Analog Input, 0-5VDC 8 Channel Analog Input, 0-1VDC 4 Relay Outputs 4 Solid State Pulse Outputs 8 Digital Status Inputs I/O Module Mounting Brackets Additional I/O Power Supply Single User Dial-in Server License AIREPORTS Single User License

29b


L

E-Mon D-Mon Three Phase Energy Meters G208

• Direct-read 8-digit LCD display without multiplier displays accumulative kWh & "real-time" kW load • User entered cost per KWH provides to-date energy cost & projected hourly cost based on metered load • Displays total carbon (CO2) emissions in pounds (lbs.) & indicates hourly emissions based on metered load • Utility Grade metering accuracy • Split-core current sensors install without power interruption, promote enhanced safety and allow remote mounting up to 2000 feet from meter • Current sensor installation diagnostic indicator • Parallel up to three sets of current sensors for cumulative reading • Industrial-grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installations • Optional removable terminal block for pulse output • Non-volatile memory • UL Listed/CSA approved, made in USA • Certified to ANSI C12.1 and C12.16 electronic meter National Accuracy Standards • Certified to California metering standards Bureau of Weights and Measures • New York City approved, Con Edison approved for RSP program

Net Meter (GN Model) adds: • Direct-read 8-digit LCD display of: • Delivered kWh • Net kWh • Received kWh • Real-time kW load • Load profile data of delivered kWh, delivered kVARh and received kWh along with real-time readings of Power Factor, kW, kVA, kVAR, Amps per phase, Volts per phase and Frequency (available via E-Mon Energy software) • RS-232/RS-485 Communication • Optional Telephone Modem, Ethernet & Modbus • Listed as eligible system performance meter by Califorina Solar Initiative Emerging Renewables Program

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Example G208100R KIT

A A

B

C

D

B

C

D

E

Model G 3-phase Green Energy Meter GN 3-phase Green Energy Net Meter System Configuration 208 120/208-240V, 4W or 240V, 3W 480 277/480V, 4W or 480V, 3W Split-core Sensor Rating* 100 100A (7/8" x 1 1/2" window) 200 200A (7/8" x 1 1/2" window) 400 400A (1 1/2" x 2 3/4" window) 800 800A (3 1/4" x 4 1/2" window) 1600 1600A (3 1/4" x 4 1/2" window) 3200 3200A (6" x 8" window) Options M MMU mounting style (Model G only) M Telephone modem (Model GN only) R NEMA 4X Outdoor enclosure E Ethernet communications (Model GN only) RTU Modbus protocol (Model GN only)

E KIT

Includes meter & 3 split-core current sensors

*Current sensors can be installed up to 2000' from meter. Indoor enclosure is 7 1/4" H x 7" W x 3 1/4"D with 3/4"conduit knockout on bottom.

E-Mon D-Mon Multiple Meter Cabinets • Compact installation of multiple meters allows for easy and centralized reading. • Available in configurations for up to 8, 16, or 24 meters. Meters can be factory installed to speed system installation. • IDRs (Interval Data Recorders) can be factory installed along with the meters, for easy interface to the E-Mon Energy software. • Three-phase MMU cabinets include prewired voltage feeds.

Model MMU8 MMU16 MMU24

Capacity 8 meters 16 meters 24 meters

Arrangement 2 across, 4 down 4 across, 4 down 5 across, 5 down

Dimensions 24"H x 12"W x 7"D 24"W x 20"H x 7"D 30"W x 24"H x 7"D

L

ORDERING INFORMATION

MMU

30

DIGITAL METERS

LSplit-Core Sensor

NEW


E-Mon D-Mon Wireless Energy Meters

DIGITAL METERS

Class 2100 Three Phase Meters

L RWT

NEW

All E-Mon products are Made in USA.

• Direct-read 8-digit LCD displays kW load & accumulative kWh. • Demand option displays kW Demand & kW Peak date and time (15 min interval standard, 30 min available). • Certified to ANSI C12.1 & C12.16 for Utility Grade Metering Accuracy (±1% from 1-100% of rated load). • Built-in wireless transceiver is FCC certified not to interfere with existing infrastructure. • Operates in the 915 MHz frequency-hopping, spread-spectrum license-free band.

• Interfaces with E-Mon wireless gateways & software for in-building remote data collection. • Self-configuring wireless mesh network installs easily, without network management. • NEMA 4X outdoor enclosure has 3/4" conduit knockout on bottom. • Non-volatile Memory retains data during power interruption. • Meters can be mounted inside building (range ~500 feet line-of-sight, up to 200 feet through walls). • Split-core current sensors install without power interruption, up to 2000 feet from meter. • Current sensor diagnostics assist in installation

Dimensions: 71/2" H x 71/2" W x 4" D

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number.

Example: 208100RWT KIT A

A

B

C

D

B

C

D

E

System 208 120/208-240V, 4W or 240V, 3W 480 277/480V, 4W or 480V, 3W Split-core Sensor Rating 100 100A (7/8" x 11/2" window) 200 200A (7/8" x 11/2" window) 400 400A (11/2" x 23/4" window) 800 800A (31/4" x 41/2" window) 1600 1600A (31/4" x 41/2" window) 3200 3200A (6" x 8" window) Model RWT Three phase Wireless Energy Meter Options (omit if no options) D Demand

E KIT

Includes meter & 3 split-core current sensors

L

Class 4100 Single Phase Meters

WT

UL Listed. New York City approved. Con Edison approved for RSP program. Measurement Canada approved for revenue metering. California Bureau of Weights and Measures certified. Made in USA.

• Easy-to-read 6-digit electro-mechanical display for diagnostics. • Interfaces with E-Mon wireless gateways & software to automatically compile data. • Can be mounted inside buildings within ~ ~500 feet line-of-sight from each other (up to 200 feet through walls) • Revenue grade accuracy meets ANSI C12.1 and C12.16. • On-board data memory. • Split-core current sensors allow for safe installation up to 2,000 feet from meter. • Non-metallic enclosure is ideal for installation inside commercial and residential spaces. • Built-in wireless transceiver is FCC certified not to interfere with existing infrastructure. • Wireless mesh network operates in the 915 MHz license-free band. • Self-configuring network allows for easy installation - no network management required.

Dimensions: 7" H x 6" W x 2" D Split-core current sensors have 7/8" x 11/2" window

ACCESSORIES

ORDERING INFORMATION 2120100WT KIT 2120200WT KIT 3208100WT KIT 3208200WT KIT

31

120V, 1-Phase, 2W meter with one 100A split-core sensor 120V, 1-Phase, 2W meter with one 200A split-core sensor 120/208-240V, 1- or 2-Phase, 3W meter with two 100A split-core sensors 120/208-240V, 1- or 2-Phase, 3W meter with two 200A split-core sensors

WGATEWAY WRSOFT

Wireless Gateway Wireless Meter Reading Software


E-Mon D-Mon Single Phase KWH Meters Dimensions: 6 3/4" H x 5 3/16" W x 31/4" D Split-core current sensors have 7/8" x 11/2" window

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Example 2120100-SA KIT

L

A

Class 1000

A

C D 3

• Industrial grade JIC steel enclosure for indoor installations with /4" conduit knockout on bottom • UL/CUL Listed, made in USA • New York City approved, Con Edison approved for RSP program, Listed by the California Energy Commission

C

D

E

System 2120 120V, 2-Wire (1 sensor) 3208 120/208-240V 3-Wire (2 sensors) 2277 277V, 2-Wire (4 digit display, 1 sensor) Split-core Sensor Rating 25 25A 50 50A 100 100A 200 200A Model -SA Class 1000 Single phase KWH Meter Options (not available on 277V systems) M MMU mounting style R NEMA 4X outdoor enclosure

E KIT

Includes meter & split-core current sensor(s)

E-Mon D-Mon ENERGY™ Software E-Mon Energy software allows users to read and monitor energy consumption easily and effectively via on-site or off-site non-dedicated computers. Requires E-Mon meter with RS-485 or wireless interface. • Windows 2000, XP & Vista compatible • Graphic profiling provides analytical charts and graphs with demand profiling for 5-, 15-, 30- or 60-minute sampling rates • Generate and print itemized electric bills (using coincidental peak demand date and time). Software will generate bills from userspecific time periods via profile data • Reads up to 8 time periods, 4 seasons and multiple holidays for time-of-use (TOU) monitoring • Reads E-Mon D-Mon meters, either on-site or off-site, via modem (cellular or telephone), Ethernet or a directly connected computer • Exports data to spreadsheets for analysis (.csv files) • Exports data to MV-90 system (.hhf files) • Optional modem allows meters to be read anywhere in the world where telephone or cellular service is available. • Wireless metering option allows users to remotely read Class 2100 & Class 4100 E-Mon D-Mon meters via Internet, Ethernet or telephone communication.

ORDERING INFORMATION EMONENERGYSW WRSOFT IDR-8 IDR-16 RS232K USBK EKM-T EKM-E

Energy Monitoring Software* Wireless Option for Software 1-8 Meter IDR** 1-16 Meter IDR** E-Mon Energy Key USB Key Telephone Key/Modem Ethernet Key/Modem

*Software packages include RS-232K Key (RS-485 to RS-232 converter) ** Available with optional two-screw removable terminal blocks. Add suffix “ST” to the end of the model number. (i.e. IDR-8-ST)

32

DIGITAL METERS

B

• Direct-read kW & kWh (no multiplier) • 8 digit LCD readout • Revenue-grade accuracy: ±1% from 1-100% of rated load • Retains readings during power failure • Split-core sensors for safe & easy installation up to 2000 feet from meter • Parallel up to three (3) sets of current sensors for cumulative reading.

B


E-Mon D-Mon Three Phase kWh/Demand Meters Class 2000

Dimensions: 7¼" H x 7" W x 3¼" D

• Direct-read 8-digit LCD display of accumulative kWh and "real-time" kW load (no multiplier). • Demand option displays kW/Demand and kW Peak date and time (15 minute interval standard, 30 minutes available) • Utility Grade metering accuracy • Split-core current sensors install without power interruption and allow remote mounting up to 2000 feet from meter • Current sensor installation diagnostic indicator

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: 208100DR KIT B C D A A B

• Parallel up to three (3) sets of current sensors for cumulative reading • Use on 3Ø 4-Wire, 3Ø 3-Wire & 2Ø 3-Wire systems • Optional removable terminal block for pulse output • Industrial-grade steel enclosure standard (for indoor installation); MMU (Multiple-Meter Unit) cabinet & NEMA 4X raintight enclosure optional • Non-volatile memory

C

• UL Listed/CSA Approved, Made in USA D

KIT

Includes meter & 3 split-core current sensors

• Certified to California metering standards Bureau of Weights and Measures. Listed by the California Energy Commission. New York City approved, Con Edison approved for RSP program.

System 208 120/208-240V, 4W or 240V, 3W 480 277/480V, 4W or 480V, 3W Split-core Sensor Rating 100 100A (7/8"x1½" window) 200 200A (7/8"x1½" window) 400 400A (1½"x2¾" window) 800 800A (3¼"x4½" window) 1600 1600A (3¼"x4½" window) 3200 3200A (6"x8" window) Options (omit if no options) D Demand M MMU cabinet R Outdoor enclosure ST Removeable terminal block for pulse output

Class 2000

IDR

E-Mon D-Mon Interval Data Recorder • Reads & records up to 8 or 16 meters; read meters individually or in groups • Reads kWh (kilowatt-hours) and reads kW (Demand) in 15, 30 or 60-minute kW periods

Use wth any model E-Mon Energy Meter except wireless units. First meter (which supplies power to IDR) must be within 100 ft. Other meters can be up to 500 ft from IDR. Dimensions: 9½" H x 6¾" W x 3¾" D

• Internal data storage for 36 days of 15-minute intervals • RS-485 communications to computer and other IRDs. Baud rate selectable up to 19200 bps • Also supports up to 52 Class 3000 meters in either "daisy chain" or "star" configuration • Powered from E-Mon D-Mon meters (IDR-ST requires 120V power) • Non-volatile memory maintains data in case of power failure • Can be mounted on the inside back wall of the MMU cabinet • Industrial-grade JIC steel enclosure has padlocking hasp, mounting flanges & three ¾" conduit knockouts on bottom

32a

ORDERING INFORMATION IDR-8 IDR-16

Interval Data Recorder for up to 8 meters Interval Data Recorder for up to 16 meters

Options: For screw terminals in place of all RJ jacks, add suffix ST to the end of the model (e.g IDR-8-ST) For IDR-16 with 8 RJ Jacks and 8 screw terminals, add suffix RJST to the end of the model (IDR-16-RJST) For Built-In Telephone Modem, add suffix M For Modbus communication, add suffix RTU


Conzerv Power and Energy Meters

Multiple Parameters Measured Auto-Scrolling Display 3-Phase Wiring Check 1/8 DIN Dustproof Case User Selectable Star/Delta, 1A/5A CT, CT & PT Ratios • Wide Range Auxiliary Supply • 10 Year Backup of Integrated Energy Data

INTEG 3PH Energy

• • • • •

OLD 3PH Energy

DIGITAL METERS

L ELF 3200

RMS Total L1 L2 L3

RMS AVG L1 L2 L3

3259 Parameter V A %Load %Unbal F RPM W VA VAR PF Wh VAh VARh -VARh Wh VAh VARh -VARh

W

3234 3234-3 VA VAR PF W VA VAR

SPECIFICATIONS TRMS Sensing: Voltage Inputs: Current Inputs: Range: Burden: Frequency: Display: Sequence: Resolution: Accuracy CL 1.0:

4 quadrant power, 2 quad. energy 4, 80-500V L-L 3, field selectable 1A or 5A 50mA to 6A 0.2VA max per phase 45-65Hz 4 digit 0.55” LED Parameter, Value Energy 8 digits, all others 4 digits W, Wh & PF Class 1.0, VAR & VARh Class 2.0, all other parameters 1.0% of rdg. Accuracy CL 0.5: W, Wh & PF Class 0.5, VAR & VARh Class 1.0, all other parameters 0.5% of rdg Aux. Supply: 80-270V, 45-65Hz, 3VA Temperature: -10 to 60°C operating, <95% RH Dimensions: 96 x 48mm, 40mm behind panel

Notes: OLD are previous energy values. VA measurements selectable for 3D or Arithmetic.

ORDERING INFORMATION Optional Accessories: 96 x 96 Adapter Plate Clamp-on Current Probes Fused Voltage Probes (1, 3, 4)

CZ/ELF3259-xx CZ/ELF3234-xx CZ/ELF3234-3-xx

Digital Voltage, Current & Frequency Meter Digital Power & Energy Meter*: W & Wh; VA & VAh; VAR & VARh; PF Digital Power & Energy Meter*: W & Wh & PF; VA & VAh & PF; VAR & VARh & PF

xx specify either 1.0 or 0.5 Accuracy Class *ELF Power Meters are user programmable to display any one set of parameters separated by ;

SPECIFICATIONS Input: Range:

L DM32 Series • • • • • •

1 Phase, 3 Phase & DC Versions Accuracy Class 1.0 & 0.5 Compact 96 x 96 mm DIN Case Built-in Phase Selector Switch Screw Terminal Connections Super Bright 0.5" LED Display

Optional Accessories: 144 x 144 Adapter Terminal Block Cover Connection Leads (one/three pair) Fused Voltage Probes (1, 3, 4)

Frequency: Burden: Overload:

1ø 2-wire or 3ø 3-wire/4-wire Nominal Span 63.5V 51-76V 110V 80-130V 240V 170-270V 415V 330-470V 1A 0.05-1.2A 5A 0.25-6.0A 45-65Hz 0.2VA max per phase Volts: 800V for 5 sec. 5A: 6X for 10 sec., 20X for 1 sec. 1A: 1X for 10 sec., 30X for 1 sec.

Class 1.0: ±1% of FS ± 1 count Class 0.5: ±0.5% of FS ± 1 count Class 0.2: ±0.2% of FS ± 1 count Display: 3 digits (800 counts FS) for V & A 31/2 dgits (1600 counts FS) for Class 0.5 4 digits for Frequency (reads Aux Supply) Resolution: 1 count in 100 or better Temperature: 0 to 50°C operating, <95% RH non-condensing Aux. Supply: 110V Nom. 80-150V AC 240V Nom. 170-300V AC Dimensions: 96 x 96 mm bezel, 80 mm behind panel Warranty: 1 year

ORDERING INFORMATION Example: CZ/DM3252–1.0–110VAC–5A–1200:5 Model Input Aux. Supply CZ/DM3250 Single Phase Volts 63.5V** 110VAC CZ/DM3251 Single Phase kV 110V 240V** CZ/DM3256 Three Phase Volts 240VAC 415V CZ/DM3257 Three Phase kV CZ/DM3252 Single Phase Amps 1A 110VAC CZ/DM3259 Single Phase kA CZ/DM3258 Three Phase Amps 5A 240VAC CZ/DM3261 Three Phase kA CZ/DM3270 Single Phase Frequency Ext or Aux* 110VAC CZ/DM3290 DC Volts 10-500V* 240VAC 75 or 60mV* CZ/DM3291 DC Amps*** ** *input from shunt

33

Accuracy:

*specify

Accuracy

PT/CT Ratio

1.0 0.5

specify PT ratio

1.0 0.5

specify CT ratio

0.2 1.0 0.5

**single phase models only


Conzerv Power and Energy Meters

NEW

L

®

Simultaneous Sampling of Volts & Amps Programmable CT & PT ratios Built-in Phase Analyzer RS-485 Modbus Serial Port ‘One Touch’ Operation and Setup Measure 4 Quadrant Power & 2 Quadrant Energy Demand Monitoring (Optional) Auto-Scrolling 3 Line, 4 Digit LED Display Color-Coded Analog Load Bar (%A FS) Wide Range Auxiliary Supply

DIGITAL METERS

• • • • • • • • • • EM6400

SPECIFICATIONS EM6459 • Displays Volts, Amps, Frequency / PF simultaneously • Monitors generator speed • Monitors generator loading efficiency

EM6433 • Monitors load currents, active power & energy consumption • Displays Amps & Power simultaneously

EM6434 • Analyzes motor performance • Monitors loading characteristics of motors • Monitors motors efficiency 59

64

Par ame ter s V1, V2, V3, V12, V23, V31 A1, A2, A3 Freq % Load - Amps % Unbal - Amps Power Factor 1, 2, 3 RPM Phase Angle 1, 2, 3 W1, W2, W3 VA1, VA2, VA3 VAR1, VAR2, VAR3 THD% on V1, V2, V3 THD% on A1, A2, A3 Demand W or VA Rising demand, Max Demand Time remaining Hour of Max demand INT: Wh INT: VAh, VARh, -VARh INT: Run hours INT: Interruptions, On hours INT W I/E: Wh INT W I/E: VAh, VARh, -VARh INT W I/E: Run hours OLD: Wh OLD: VAh, VARh, -VARh OLD: Run hours

33

64

34

64

36 400 6

64

O O O O O O

O O O

O = optional

EM6436 • Monitors active power & energy consumption, system voltage, load current and PF • Displays Amps, Power, PF simultaneously EM6400 All of the above plus: • Optimizes demand utilization • Analyzes power quality • Helps energy balancing

Demand Parameters Option (EM6400) • Monitors Demand – Present, Rising & Maximum, Time remaining • VA & W demand is selectable through setup table • Demand may be Sliding window (auto) or Fixed window (User), selectable through setup mode • The time of occurrence for the Maximum Demand is based on “On hrs” of the system • Maximum Demand can be cleared independently or along with the integrators through the CLR function in the setup mode

Sensing: Measurement:

True RMS, 1 sec update time 4 quadrant Power & 2 quadrant Energy (4 quadrant optional) Input voltage: 4 Voltage inputs 110 or 415 V L-L nominal Range: 80 to 600V L-L Input current: 3 current inputs, field configurable 1A or 5A Range: 20mA – 6A Overload: 10A cont., 50A for 3 sec Burden: 0.2VA max per Volts/Amps input Frequency: 45-65Hz Aux supply: 44-300 V AC/DC, 3VA max Resolution: RMS 4 digit, INTEG 8 digit Communication: 2-wire RS-485, Modbus RTU Demand: Integration period 5-30 minutes in 5 minute increments Environment: -10°C to +60°C operating, 5-95% RH non condensing Dimensions: 96x96mm bezel, 80mm behind panel Measurement Accuracy (% Reading) Volts L-N, L-L per phase & Avg Amps per phase & Avg Amps phase angle per phase Frequency Real Power per phase & total Reactive Power per phase & total Apparent Power per phase & total Active Energy Import/Export Reactive Energy Apparent Energy RPM

CL1.0 1.0 1.0 2° 0.1 1.0 2.0 1.0 1.0 2.0 1.0 1.0

CL0.5 0.5 0.5 1° 0.1 0.5 1.0 0.5 0.5 1.0 0.5 0.5

These meters can be setup using the front panel or a free GUI based software utility.

ORDERING INFO CZ/EM6459-xx CZ/EM6434-xx CZ/EM6436-xx CZ/EM6400-xx CZ/EM6400-xxPlus

Programmable Multi-function Meter: V, A, F, PF Programmable Multi-function Power & Energy Meter Programmable Multi-function Meter: V, A, F, PF, Power & Energy Programmable Multi-function Meter Programmable Multi-function Meter with Demand, THD & Bi-directional

xx specify either 1.0 or 0.5 Accuracy Class

34


NEW

Conzerv Power and Energy Monitors • • • • • • •

Record and Analyze Power & Energy Data of Energy Intensive Loads Auto Scrolling Display of up to 16 User Selectable Parameters Separately Monitor Import/Export of Energy (optional) Store Previous Period Integrated Data Built-in Phase Analyzer Data Maintained During Power Failure 6 Digit Readout for Energy Parameters, 4 Digit Readout for Instantaneous Parameters User Programmable 60 80 60 33 34 34

Feature

EM3360

EM3360 • Offers comprehensive power and energy monitoring at feeders and individual loads • Retrieves previous energy reading to cross check utility meter readings or electricity bills • Analyzes loading patterns • Visualizes unbalances in system • Checks for wrong connection, reversed phase sequence, deteriorating power factor compensation on one of the phases, etc. EM3480

All benefits of EM3360 plus: • Offers Demand Monitoring • Ensures automatic synchronization of demand with utility meter • Displays Max demand along with date and time of occurrence • Helps to set realistic demand target

Voltage L-L per phase & average Voltage L-N per phase & average Voltage Neutral to earth Current per phase & average Neutral current Phase Angle %THD V1,V2,V3, I1,I2,I3 Line Frequency, Generator RPM kW, kVA, kVAR per phase & total PF per phase and 3 phase kWh, kVAh, KVARh, Ah; avg: PF, Hz, V Run hours & number of interruptions Demand: instantaneous & maximum Settable upper/lower limits & interval 3 Demand limit alarm outputs High/Lo data store High/Lo max. demand profile store 19 level Demand Target profile Real-time clock w. On/Off & run times Relay outputs for load control User settable demand targets

All benefits of EM3480 plus: • Predictive feature enables prior indication of crossing demand • Facilitates tripping of non essential loads • Analyzes electrical faults & planning of load schedules • Optimizes demand utilization • Improves system efficiency These meters can be setup using the front panel or a free GUI based software utility.

• EHT, HT or LT, Delta 2E or Star 3E measurement; PT & CT Ratios; kVA or kW Demand • VA measurement – 3D or Arithmetic • Demand Period (1 to 30 minutes) • Manual Synchronization (fixed window, to suit most popular EB meters) or sliding window. • Auto Synchronization: User programmable password for all Setup, Demand Synchronization and Clear Functions. From Software:

• TOU calendar

• Monthly auto reset date

SPECIFICATIONS Sensing:

EM3460

From Front Panel:

3 Phase, 3 Wire/4 Wire (field configurable) Measurement: True RMS Voltage Input: 110 to 415 VAC nominal Range: 80 – 500V Current Input: 5 or 1 Amp nominal (factory set) Maximum: 120% of nominal Burden: 0.2 VA Max. Frequency: 50 Hz ± 5%, 60 Hz ± 5% Auxiliary Supply: Factory Set, Single Phase, 240V (190-270V) or 110V (85-130V), 5VA max. Power Factor: 0.5 PF Lag – Unity – 0.8 PF Lead

Accuracy:

For V, A, PF, all Power & Energy parameters Class 1.0: ± (0.2% of Full Scale + 0.8% of reading + 1 digit) Class 0.5: ± (0.1% of Full Scale + 0.4% of reading + 1 digit) Accuracy of Hz: ± 0.2% of reading Accuracy of Ø: ± 1° (20% to 120% of Full Scale) Display: 7 digit, 0.56" LED, auto scaling (kilo/Mega) Temperature: 0° - 60°C operating Dimensions: Bezel 192 x 144mm, 110m behind panel Panel Cutout: 186 x 138mm (+ 1.0 mm)

ORDERING INFO Example: CZ/DM3360–1.0–5A–110–R–TOU–485–IE Model Accuracy CZ/EM3360 Power & Energy Monitor 1.0 CZ/EM3480 Trivector Monitor CZ/EM3460 Smart Demand Controller

34a

0.5 0.2

Input 1A 5A

Aux. Supply Enable VAC Auto Reset R=on 110 x=off 240

specify date & time

Enable TOU (x=off)

Comm Port Import/ (RS-485) Export

Energy Energy+MaxDM Energy+MaxDM+ DM Ctrl

485=install x=none

IE=on x=off


National Meter KW Hour Meters Three Phase Energy & Demand Meters

Displays kWhrs and kW Demand along with Volts, Amps and real time kW per phase.

K4000PM

SPECIFICATIONS

▲ KW4000

SPECIFICATIONS Accuracy: Burden: Operating Temperature: Relay Output: RS-485: Dimensions: Enclosure: Connections: Dimensions: Standards:

• Six Digit kWh LCD Display • L1, L2 & L3 Power Readings • Three Digit V, A & kW Readout • kWh Pulse Relay • RS-485 Modbus RTU Output • Use with CTs Rated to 10,000A

• 3Ø Revenue Class Meter • 9 Digit LED Display • Field Programmable • Memory Backup Without Batteries • Direct Energy Display – No Multipliers

ANSI C12.16 Isolated CT circuit, burden 0.06VA -10°F to 120°F, <95% RH non-condensing SPST Form A, 240VAC@10A resistive 4 wire 7.5"W x 8" H x 3.5" D Surface mount, ABS plastic, NEMA 1 Screw terminals 5.6" W x 8.1" H x 3.5" D UL61010B-1,CUL

Max Display: Accuracy: Burden: Operating Temperature: Relay Output: Contacts: Indicator: Enclosure: Dimensions: Standards:

999,999,999 kWh ±0.5% ±2d Isolated CT circuit, burden 0.75VA -10°C to 50°C Energy/alarm pulse, 1/sec max rate 440VAC, 10A, 2500VA resistive Front panel LED UL VO rated plastic, NEMA 1 3.78"W x 3.78" H x 3.3" D CAT III 300V, Class II double insulated

ORDERING INFORMATION CAT NO. NM/KW4240 NM/KW4480 NM/K4240PM NM/K4480PM

DESCRIPTION 120/208/240V 3Ø, 3 or 4 Wire, KWh/Demand Meter 277/480V 3Ø, 3 or 4 Wire, KWh/Demand Meter 120/208/240V 3Ø, 3 or 4 Wire, KWh Meter 277/480V 3Ø, 3 or 4 Wire, KWh Meter

400A solid core CTs included. Split core and larger sizes available. Single phase models also available.

34b


NLS Panel Meters ORDERING INFORMATION

MINIATURE PANEL METERS

DIGITAL METERS

L

PM349 • 0.1% Basic DC Accuracy • Small Stackable Case • Red, Green or Yellow Display • Presettable Decimal Point • MUX BCD Outputs Temperature: 0-50°C operating Case Size: 3.125"W x 1.375"H x 3.375"D

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: NL/PM349/L/G/CS/5/20V D Reading A – B – C – D – E – F – Normal S Scaled (specify value) A Model Z Offset (specify value) NL/PM349 31/2 digit DC Voltmeter CS Internal current shunt (specify range) 1 NL/PM352 3 /2 digit DC Voltmeter AC AC reading (PM352 only) 1 NL/PM452 4 /2 digit DC Voltmeter E Power B Dislay Option – Normal – 0.3" LED digit height 5 5VDC ±5%, 200mA L Large 0.4" digits 120 with 120VAC adapter C LED Display Color 240 with 240VAC adapter R Red F Range Rin Y Yellow 200mV 100MΩ (PM349 only) G Green 2V 1000MΩ 20V 1MΩ 20V 10MΩ 1000V 10MΩ

SHORT DEPTH DC VOLTMETERS

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: NL/X37/L/-/20V A – B – C – D – E A

X37

L

• Only /2" behind panel • 0.56" LED or 0.6" LCD • 0.1% or 0.2% Accuracy • Presettable Decimal Point

B

1

Power:

5VDC ±5%, 200mA (6mA for X37) Temperature: 0-50°C operating Case Size: 4"W x 1.9"H x 1.1"D 1/8 DIN PANEL METERS

L

RM350 • 0.1% or 0.2% Accuracy • Amps, AC, Ω, Ratio Options • Power Supply Options • MUX BCD Outputs Temperature: 0-50°C operating Case Size: 4.0"W x 1.9"H x 4.5"D

35

C

D

Model NL/X32 3 digit, LED (unipolar) NL/X34 31/2 digit, LED (bipolar) NL/X37 3 digit, LCD (bipolar) Dislay Option L Backlit LCD – Standard LCD or LED LED Display Color R Red LED Y Yellow LED G Green LED – LCD

E

Reading – S Z CS Range

Normal Scaled (specify value) Offset (specify value) Internal current shunt (specify range) X32 100mV 1V 10V 100V 1000V

X34, X37 200mV 2V 20V 200V 1000V

Rin 100MΩ 1MΩ 1MΩ 1MΩ 4MΩ

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: NL/RM350/TB/-/G/AC/120/20V E Reading A – B – C – D – E – F – G – Normal S Scaled (specify value) A Model Z Offset (specify value) NL/RM350 31/2 digit, 0.56" LED CS Internal current shunt (specify range) NL/RM351 31/2 digit, 0.6" LCD AC AC reading NL/RM452 41/2 digit, 0.56" LED Ohm Ohms reading F Power NL/RM453 41/2 digit, 0.4" LCD 5 5VDC ±5%, 200mA B Connector (mating connector included) 12 12VDC TB Terminal block 24 24VDC EC Edge connector 28 28VDC C Dislay Option 18 18-34VDC isolated – Standard 120 120VAC L 0.8" LED 240 240VAC (RM350 only) G Range Rin D Display Color R Red LED 200mV 100MΩ (RM3xx only) Y Yellow LED 2V 1000MΩ G Greeen LED 20V 1MΩ – LCD 20V 10MΩ 1000V 10MΩ


Martel Digital Panel Meters 700 Series

L

DPM950

DPM959

• 1/2" (or 2 x 1/4") Digit Height • LED Backlight • ±200mV A/D • IP67/NEMA 4X Bezel Option^

ORDERING INFORMATION Model Function Accuracy ±1d Supply VDC DPM950 DCV* ±0.05% 7.5-14 DPM950S DCV* ±0.05% 3.5-6.5 DPM595B DCV* ±0.05% 4.5-5.5 DPM942 4-20mA ±0.05% loop pwr DPM970 ACV* 0.5% 7.5-14 DTM910 °C/°F (Pt100 RTD) 1°C 4.5-5.5 DTM995 °C (Type K TC) 1% 7.5-24 *Specify input range or internal shunt for current measurement.

35/65 Series • Red LED, Green LED or LCD • Voltage or Process Inputs • Display Hold • 5V power

L

SPECIFICATIONS 35x Panel Cut-out: 35x Mounting: 65x Dimensions: 65x Panel Cut-out: 65x Mounting: Digit Height: Accuracy: Operating Temp: Power:

2.57" x 1.10” x 0.77" (64.0 x 28.0 x 16.8mm) 2.05" x 0.81” (52.1 x 20.6mm) Window or bezel 2.3" x 1.1” x 0.71" (59 x 29 x 18.1mm) 2.22" x 1.04” (56.5 x 26.5mm) Snap-in bezel 0.56" LED, 0.39" LCD ±0.05% ±1d typ. 0°C to 50°C 5VDC ±5%

ORDERING INFORMATION DPM35R DPM35G DPM65 DPM65S

SPECIFICATIONS -BL Dimensions: -BL Panel Cut-out: 702S Dimensions: 702S Panel Cut-out: Operating Temp: LCD Backlight:

2.57" x 1.39” x 1.36" (65.2 x 35.2 x 32.0mm) 2.38" x 1.20” (60.5 x 30.5mm) 2.54" x 1.36” x 0.45" (64.5 x 34.5 x 11.5mm) 2.44" x 1.26” (62.0 x 32.0mm) 0°C to 50°C 30mA@5V (except DPM702S)

ORDERING INFORMATION Model Function Accuracy ±1d Supply VDC DPM750S-BL DCV* ±0.1% 3-15 DPM702S DCV* ±0.05% 3.5-7 DPM742-BL 4-20mA ±0.1% loop pwr *Specify input range or internal shunt for current measurement. ^IP67 bezel not available on DPM702S

EM32 Series 35X

35x Dimensions:

DIGITAL METERS

Panel Cut-out: Operating Temp: LCD Backlight:

2.99" x 1.73” x 0.51" (76.0 x 44.0 x 15.0mm) 2.83" x 1.57” (72.0 x 40.0mm) 0°C to 50°C 50mA@5V (except DPM942)

DPM750S

DPM702S

SPECIFICATIONS Dimensions:

L

L

• LED or Backlit LCD • Large 0.75” Digit Height • ±200mV A/D • IP67/NEMA 4X Bezel Option

L

900 Series

Red LED DPM, differential input Green LED DPM, differential input LCD DPM, differential input LCD DPM, single-ended input

• 0.31" Digit Height • Metal Bezel • Mounts in 32.5mm (1.28") Cutout • IP67/NEMA 4X Front EM32

L

SPECIFICATIONS Dimensions: Accuracy: Input: Operating Temp: Power:

1.5" dia x 0.93" (38.0 x 23.5mm) excluding pins ±0.1% ±1d typ. ±200mV DC* 0°C to 50°C 5VDC ±5% @500microA (50mA for LED)

ORDERING INFORMATION EM32-1B Circular LCD DPM EM32-1B-LED Circular LED DPM *Specify other ranges or internal shunt for current measurement.

36


Martel Quick Mount LCD Panel Meters QM130M Wiper Type

QM100V40 2-Wire Voltage •Monitoring System Voltage •Powered from Measured Signal •Reverse Polarity Protected

DIGITAL METERS

• 9 Segment LCD • Color Scale

Input: Resolution: Supply:

0-1 VDC 125 mVDC 5–12 VDC @ 1.5 mA

Input: Accuracy: Max:

4.0-40.0 VDC 0.4V ± 1 count 50 VDC @ 3 mA

QM140V Voltage/Current

QM120C Elapsed Time

•200 mV Full Scale •Auto-zero, Auto-polarity •Optional Ranging Board

•9999.9 and 99999 Hour Ranges •Reset & Trip/Total Inputs •Pulse Output every 100 Hours

Ranges:

200mV, 2V, 20V, 200µa, 2ma, 20ma, 200ma Accuracy: 0.05% ± 1 count Supply: 7.5-15 VDC @ 150 µA

• Readout in Degrees C or F • Reads Internal Sensor or External 10kΩ NTC Thermistor

Resolution: Supply

5-27 VDC @ 2.5 µA

SPECIFICATIONS FOR ALL METERS

QM110T Temperature

Range:

Supply:

Internal Sensor -10 to +50°C -14 to +122°C 0.5° 4-28 VDC

Sample Rate:

3 sec.

Character Height:

0.5" (12.5mm) except 0.35"(9mm) on QM120C

External Sensor -20 to 220°C -4 to +428°F 1° 4-28 VDC

Operating Temperature:

0-50°C

Dimensions (W x H):

1.71" x 0.84" (43.0 x 21.4 mm)

Mounting:

7/32" (5.5 mm) hole

Sealing:

IP65 Front

Yokogawa Loop Powered Indicators L

• Explosion-Proof NEMA 4X Case • Analog and Digital Models • FM and CSA Approved Versions • Wall Mount or 2" Pipe Mount

MLD

SPECIFICATIONS Input Resistance:

Standard Scale: Accuracy: Operating Temperature: Electrical Classification:

Case and Cover: Electrical Connection:

100Ω (MLD 4-20mA) < 6.5Ω (MLA 4-20mA) < 13.5Ω (MLA 10-50mA) ~4kΩ (MLA 1-5V) 0-100.0% (MLD) 0-100% (MLA) ±0.05% of full scale [1999] ±1 digit (MLD) ±1.5% of full scale (MLA) 0 to 60°C (MLD), -20 to 60°C (MLA) FM, CSA, EXPLOSIONPROOF CL1, DIV1, GPS A,B,C,D, DUST-IGNITIONPROOF CLII / III, GPS E,F,G Die cast aluminum, baked polyurethane paint. Dark green; NEMA 4X 1 /2" NPT

For special analog scale, add /SC to catalog number and describe (i.e. 0-300 PSI). For special digital readout, add /ENG to catalog number and describe (i.e. 50.0-150.0 GPM).

37

ORDERING INFORMATION A

A

B

C

D

E

B

C

D

E

Example: MLD-A2/FF1/WHT

Model MLA Loop Indicator (Analog) MLD Loop Indicator (Digital) Input Signal -A 4 to 20 mA DC -B 10 to 50 mA DC (MLA only) -C 1 to 5 VDC (MLA only) Mounting 1 2" Horizontal Pipe 2 2" Vertical Pipe (or wall mount) Electrical Class /FF1 FM Explosion Proof /CF1 CSA Explosion Proof Options / WHT White scale or face plate /ENG Engineering Unit Calibration (MLD Only) / SC Scale in Engineering Units (MLA Only) / SST Stainless Steel Tag -Up to 8 Characters


London Electronics Large Display Meters Fusion • Analog & Digital Inputs • Large, Bright Digits • Setup Without Menus • Indoor & Outdoor Models • Choice of Mounting Position

Easy Reader

L

ER

SPECIFICATIONS

Counter Input: Signal Type:

Range: Excitation: Loadcell Input: Resistance: Excitation

Serial Input: RS232 or RS485 300-115200 baud Display: -1999 to 9999 (4d) -199999 to 999999 (6d) Accuracy: ±0.05% of range Analog Out: >1kΩ 16 bit resolution direct or inverse 250VAC isolation Relays: SPST 2A@250VAC resistive Selectable NO or NC Selectable energize or deenergize Temperature: 0-50°C operating Connectors: detachable screw terminals Power: 50VA max. Case: Black uPVC, 75mm depth

0-10V, ±13V, 4-20mA, ±24mA 1MΩ on V, 33Ω on mA 24V 60mA Type J, K, T, R, S, B 3 or 4 wire PT100 RTD 4 channels Logic level; AC tach; NPN, PNP pulses <24V; 100mV inductive pickup; Contact closure 0-40kHz 24V 60mA 4 or 6 wire >10MΩ 10V 120mA

ORDERING INFORMATION Example: Fusion2-F2-4N-P-0-AL2-232-B-AC-1-0 Fusion2 - A – B – C – D – E – F – G – H – A

B

C

D

Digit Height F2 F4 F6 F8 F12 F16 Digit Format 4N 4C 6N 6C 8N Function C H L M P S2 S4 T Analog Output 0 ANI ANV ANB

E 2" (57mm) 4" (102mm) 6" (150mm) 8" (200mm) 12" (300mm) 16" (400mm) 4 digit numeric 4 digit clock 6 digit numeric 6 digit clock 8 digit numeric Counter Clock/timer Loadcell Millivolt Process RS232 slave RS485 slave Temperature None 4-20mA 0-10V ±10V

F

G

H

I

0 AL2 AL4 SPCO DSS Serial Output 0 232 485 Display Color R G Y B W RDLV GDLV YDLV BDLV Supply AC DC Mounting 1 2 3 4 5 6

I -0 Alarm Outputs None 2 alarms 4 alarms 2 SPDT relays 2 solid state relays None RS232 RS485 Red Green Yellow Blue White Red bright Green bright Yellow bright Blue bright 95-265VAC 50/60Hz 11-30VDC Panel, IP65 front Wall, IP65 Top Suspension, IP65 Wall, IP54 Top Suspension, IP54 Rear Suspension IP54

A simple and affordable way to see and share important measurements over large distances: • 2" (57mm) digits for viewing up to 65ft (20m) • 4" (102mm) digits for viewing up to 130ft (40m) Available in 5 input types, these meters can be configured from the front panel.

SPECIFICATIONS Process Input (Type P): Accuracy: Display by: Count Input (Type C): Accuracy: Slave Input (Type S): Format: Addressing: Reset: Excitation: Operating Temperature: Power: Dimensions:

4-20mA, 0-10V, 1-5V, scalable ±0.1% range ±1d @25°C 1, 2, 5, 10, 20, 50 NPN, PNP or contact closure ±0.05% range ±1d @25°C RS232, RS422, RS485 or TTY ASCII data from 300-9600 baud 00 to FF Front panel or remote contact closure 24VDC, up to 30mA (except Slave) 0-50°C, <95% RH non-condensing 95-265VAC, 11-30VDC ER2 10.3x5.8x1.8" (260x140x45mm) ER4 16.4x7.7x1.8" (415x195x45mm) IP54 dust tight (IP65 optional)

Sealing:

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Example ER4P-2-O-O ER A B

C

D E

A

B – C – D – E Digit Size 2 4 Type P C S H T Mounting 1 2 3 6 Power 0 DC Brightness 0 DLV

2" 4" Process Input Count/rate Input Slave (ASCII) HH:MM Clock TC & PT100 RTD Flush Panel Wall Suspension Top of Cabinet 95 - 265VAC 11-30VDC Normal Ultrabright

38

DIGITAL METERS

Process Input: Resistance: Excitation Temperature Input:


Laurel Programmable Counters FUNCTIONS • • • • •

Rate, Frequency, Period Simultaneous Total & Rate Time Interval, Stopwatch Quadrature Position or Rate Ratio / Draw

DIGITAL METERS

FEATURES

• • • •

Batch Controller Analog Totalizer Phase Angle & Power Factor Duty Cycle

OPTIONS

• • ±999,999 Display Span • Scaling in Engineering Units • • • Crystal Time Base Error <0.001% • • Sensor Excitation Output • • 1/8 DIN, NEMA-4X Front Panel

Dual Relay Outputs Isolated Analog Outputs USB, RS-232 & RS-485 Data I/O Custom Curve Linearization Datalogging PC Software

Exceptional flexibility is provided by advanced programmable features and by modular architecture with a choice of main boards (basic or extended), signal conditioners (FR, VF or QD), power supplies, analog output, relay outputs, and serial data I/O. The FR module provides two independently scalable frequency/pulse input channels. These channels can be combined arithmetically to display the sum or difference of two flows, the ratio of two rates, etc. As a counter, each channel may be independently set and scaled to count up to or down from a preset value. The displayed channel (A or B) is selected via front panel pushbutton. The totals are stored in non-volatile memory & retained in the absence of power.

SPECIFICATIONS Display Six 14.2 mm (.56") high LED digits Conversion Technique Frequency measurement technique 1/period Rate Gate time + 30 ms + 0-2 input periods Gate time Selectable 0 to 199.99 sec Scale Factor ±10 -10 to ±106 Isolation 250V RMS working, 2.3kV RMS test FR Signal Conditioner (2 channels) Inputs AC, pulses from NPN or PNP transistors, contact closures, magnetic pickups Level ±12 mV min, 250 Vac max Frequency CH A: 0 Hz to 1 MHz; CH B: 0 Hz to 250 kHz VF Signal Conditioner Inputs 0-10 V, 0-1 mA, 4-20 mA Span error < 0.015% of full scale ±1 count Span tempco < 0.003% of reading/°C Zero tempco < 0.001% of full scale/°C QD Signal Conditioner Inputs Quadrature encoders to 250 kHz Polarity Differential or single-ended Error correction Zero index (z-channel) Transducer Excitation Output (std) Output 100 mA @ 5 V, 120 mA @ 10 V, 50 mA @ 24 V Isolation 50 Vdc to meter ground Data Communications (opt) Type USB, RS-232, RS-485 (2- or 4-wire) RS-485 Modbus RTU, Modbus ASCII, or Laurel ASCII Operating Temperature 0°C to 55°C

39

ORDERING INFORMATION Example: L50010FR KL Laureate™ with plug-in screw terminal connectors K Main Board 5 Meter with green LEDs 6 Meter with red LEDs 7 Extended, green LEDs 8 Extended, red LEDs K Power 0 85-264 Vac/90-300 Vdc 1 10-48 Vdc/12-30 Vac K Setpoint Output 0 None 1 Dual 8 A relays (250 Vac/24 Vdc) 2 Dual 130mA solid state relays (140 Vac/180 Vdc) K Analog Output 0 None 1 0-20 mA, 4-20 mA, 0-10 V, ±10 V K Digital Interface 0 None 5 USB 1 RS-232 (Isolated) 6 USB to RS-485 Converter 2 RS-485 (Isolated) 4 RS-485 Modbus (Isolated) K Input Type FR Frequency With main boards 5 & 6: Scalable to ±999,999 for frequency, period, up/down total, interval, rate or square root of rate. With main boards 7 & 8: Above plus rate and total simultaneously, custom curve linearization, atio, draw, arithmetic functions (A*B, A/B, A/B-1, A+B, A-B), phase angle, stopwatch, batch counting. VF1 4-20 mA VF2 0-1 mA VF3 0-10 V With main boards 5 & 6: V-to-F converter for rate or square root of rate from differential pressure or target type flow meters. With main boards 7 & 8: Above plus rate and total simultaneously, linearization of nonlinear inputs, batch counting, 1/rate (time). QD Quadrature With main boards 5 & 6: Scalable to ±999,999 for position from encoders. QDR Quadrature Rate With main boards 7 & 8; Scalable to ±999,999 for position or rate from encoders.

ACCESSORIES CBL01 CBL02 CBL05

RJ11 TO DB9 Cable to PC Com port USB to DB9 Adapter USB Cable to PC USB Port


Simpson 1/8 DIN Counter Totalizer, Rate/Totalizer/Batch

DIGITAL METERS

L S660 L

S664

• NEMA-4X Front Panel • Four Frequency Ranges Available (99 Hz, 999 Hz, 9 kHz, 35 kHz) • Easy to Use (Install/Wire/Mount, Select Range, and Go) • Bright Red LEDs for Easy Viewing • Minimum Mounting Depth Required • 120 or 240 VAC • Optional Excitation Output 12 VDC @ 100 mA • Modular Design • Screw Terminals for Easy Installation

SPECIFICATIONS Display Type: Power: Operating Temp: Size:

7 segment, bright red LED, 0.56" H 120/240 VAC 0 to 55°C 3.6" W x 1.8" H x 3.24" D (92 x 48 x 82 mm)

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: S664-1-1-0-0-0 A – B – C – D – E A B

C

D E

F

• • • • • • • •

NEMA-4X Front Panel Uses Words, Not Symbols for Easier Programming Bright Red LEDs for Easy Viewing Large, Tactile Buttons Can Be Pressed with Gloves On Standard 1/8 DIN Cutout Up to Two 5 Amp Relays Optional Optional Excitation Output 12 VDC Screw Terminals for Easy Installation

SPECIFICATIONS Display Type: Power: Operating Temp: NMRR: Size:

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: S660-1-2-2-1-0 A – B – C – D – E A

– F

Basic Unit S664 Frequency Counter Power Supply 1 120 VAC 2 240 VAC Input Type 1 Standard Pulse Input 2 Quadrature input Output Type 0 None Excitation Output 0 None 1 12 VDC Other 0 None

7 segment, bright red LED, 0.56" H 120/240 VAC 0 to 55°C 60 dB @ 50/60 Hz 3.6" W x 1.8" H x 3.24" D (92 x 48 x 82 mm)

B

C

D

E

F

– F

Basic Unit S660 Preset Up/Down Counter S661 Preset Rate Counter S662 Preset Totalizing/Batch Counter S663 Preset Totalizing/Rate Counter Power Supply 1 120 VAC 2 240 VAC Input Type 1 Standard Pulse Input 2 Quadrature Output Type 0 None 1 1 Mechanical Relay 2 2 Mechanical Relays Excitation Output 0 None 1 12 VDC Other 0 None

40


ATC Westcon Counters W3830 Series

DIGITAL METERS

6-Digit Indicator/Totalizer with Optional Outputs

W3870 Series

6-Digit Frequency Input Indicator/Totalizer with Optional Outputs

FEATURES • Automatic Square Root Extraction • Logic Controlled Up/Down Counter

SPECIFICATIONS

• Preset Up Counter • Preset Down Counter • FLUME 5/2 Calculation • WEIR 3/2 Calculation

SPECIFICATIONS MODEL: 3830-23 3830-25 3830-27 OPERATING TEMP: FRONT/CASE:

RANGE: ACCURACY: 0-5 VDC ±0.08% reading, ±0.05% FS 0-10 VDC ±0.08% reading, ±0.05% FS 4-20 mA ±0.08% reading, ±0.05% FS 0°C to 50°C (32°F to 122°F) NEMA 4X / Anodized Aluminum

RANGE: User programmable decimal, scale factors and insignificant zero blanking yield a display range of 0.00001 to 999999. INPUT RESPONSE: 0.0005 to 99,999 Hz PROTECTION: ±200 V peak SENSITIVITY: TTL, CMOS or contact compatible

PULSE WIDTH: 5 micro- seconds minimum TRIGGER MODE: Negative edge of input pulse INPUT IMPEDANCE: 12k ohms FILTER/DEBOUNCE: Front panel programmable digital filter FRONT/CASE: NEMA 4X / Anodized Aluminum

OPTIONAL OUTPUTS OPTIONAL OUTPUTS Option C:

Option H: Option P: Option T: Option V:

Option C:

3 Form-C 5 amp relay outputs activate when programmable high and low limits are exceeded. Permits on-off control of external circuitry, or alarm status communication with other equipment. 1-4 analog outputs, 0-5 VDC, ±5 VDC, 0-10VDC or 4-20 mA. Accuracy is 0.35% of scaled range. Output signals are proportional to meter display. Excitation 10VDC & 24VDC RS232C serial data communications interface at 9600 Baud rate. Totalizer pulse output. Solid-state relay (SSR). Operating range: ±80V peak. continuous load current: 150 mA. Pulse width: 60mS (consult factory if faster output is required).

Option G: Option H:

Option P: Option S: Option T: Option X:

ORDERING INFORMATION

ORDERING INFORMATION Model #:

41

3830

- XX

Input 23 25 27

0-5 VDC 0-10 VDC 4-20 mA

Options C H1 T V P

3 Relays 1 Analog Output RS232 Totalizer Pulse Output Excitation

XXXX

3 Form-C 5 amp relays activate when programmable high and low limits are exceeded. Permits on-off control of external circuitry, or alarm status communication with other equipment. Input amplifier, 30 mV peak input at 5 Hz to 99,999 Hz. 1-4 analog outputs, 0-5 VDC, ±5 VDC, 0-10VDC or 4-20 mA. Accuracy is 0.35% of operating range. Output signals are assignable to rate and total. Excitatin 10VDC & 24VDC 230 VAC Power. RS232C serial data communications interface at 9600 Baud rate. Screw terminal block connector. Accepts up to #14 AWG wire.

PRICE Model #: $ 225 $ 60 65 140 N/C 60 26

Options C G H1 S T X P

3870 Relay Outputs Input Amplifier 1 Analog Output 230 VAC Powered RS232 Screw Terminal Excitation

-

XXXXXX


KEP Counters & Timers KAL-D06 8 Digit Electronic Counter

LCD, digits 0.35" (9mm) high 8 digits with leading zero blanking Panel or external (can be disabled) Requires external 5V supply (20 mA) NPN sink; 18V, 10kHz max NPN sink or contact closure; 18V, 30Hz max NPN sink or push pull, 18V, 2.5kHz max >15ms NPN sink or contact closure; 18V max NPN sink or contact closure; 18V max (Lo=down) Count 10 pulses/sec max; opto-isolated 250VAC/120VDC max >15ms, opto-isolated 250VAC/120VDC max -10 to 60°C operating 24 x 48 x 52 mm

KAL-DTIME 8 Digit Electronic Timer • Electronic or contact closure input • Powered by 10 year lithium battery • High voltage input optional • NEMA 4X (IP65) front • UL Listed

SPECIFICATIONS Display: Readout:

Reset: Backlight: Timing Input: Reset Input: Direction Input: Hi-voltage Input: Hi-voltage Reset: Temperature: Case:

LCD, digits 0.35" (9mm) high 8 digits with leading zero blanking SECONDS: 99999999 MINUTES and SECONDS: 99999-59 HOURS and 1/100ths: 99999-99 HOURS and MINUTES: 99999-59 Panel or external (can be disabled) Requires external 5V supply (20 mA) NPN sink, negative edge trigger; 18V max >15ms NPN sink or contact closure; 18V max NPN sink or contact closure; 18V max (Lo=down) Opto-isolated 250VAC/120VDC max >15ms, opto-isolated 250VAC/120VDC max -10 to 60°C operating 24 x 48 x 52 mm

SPECIFICATIONS

924K Counter, Rate Meter & Timer • Displays actual value, presets, batch count or total count • 3 predefined parameter settings • Tracking presets • 4 stage RESET modes • 2 relay outputs • 3 stage key lockout

Display: Count Inputs: Switching Level: Count Modes Pulse:

2 line, 6 digit red LCD NPN/PNP, 5kΩ, 55 kHz max Low=0-4 VDC, High=12-30 VDC (924KA)

cnt.dir, up.dn, up.up, quad, quad 2, quad 4, A/B, (A-B)/A x 100% Frequency: A, A-B, A+B, quad, A/B, (A-B)/A x 100% Timer: FrErun, Auto, InpA.InpB., InpB.InpB. Monitor/Reset Inputs: MPI, lock, gate, reset Pulse Duration: 10 ms/1 ms min. Relay 1: Form A, programmable NO or NC Relay 2: Form C Max. Switching: 250 VAC / 110 VDC, 3 A, 750 VA / 90 W Sensor Supply: 24 VDC, 80mA Temperature: -20 to +65 °C operating Protection: IP65 (front) Case: 1/8 DIN (48 x 48 x 107mm)

ORDERING INFORMATION KAL-D06 KAL-DQUAD06 KAL-D06AC/DC

8 digit counter with 10 yr battery 8 digit counter with 10 yr battery & Quadrature Input 8 digit counter with 10 yr battery & High Voltage Input

KAL-DTIME KAL-DTIMEAC/DC 924KA* 924KB*

8 digit timer with 10 yr battery 8 digit timer with 10 yr battery & High Voltage Input Counter, Rate, Timer; 90-260 VAC power Counter, Rate, Timer; 10-30 VDC power

*Add suffix 0 for relay outputs, 1 for opto-coupler outputs

42

DIGITAL METERS

• Low speed input for contact closures • High speed input sinks 18V max • Optional quadrature & high voltage inputs • 10 year lithium battery – no external power needed • NEMA 4X (IP65) front • UL recognized

SPECIFICATIONS Display: Readout: Reset: Backlight: Hi-speed Input: Lo-speed Input: Quadrature Input: Reset Input: Direction Input: Hi-voltage Input: Hi-voltage Reset: Temperature: Case:


KEP Counter/Timer

KEP Totalizer/Rate Meter

LCD preset add/subtract counter, timer, frequency meter

Ratemeter/totalizer/process monitor from analog inputs

903K/904K Series • 6-Digit Counter, Timer or Frequency Meter • 2 Preset Values (Type 903K 1 Preset) • Input Scaling (0.0001 to 9.9999) Multiplier • 2-Line LCD Display • Count and Preset Range of -999999 to 999999

▲ INT69RT

• Add or Subtract Count Control • AC or DC Operation

▲ 904K

• Secondary Preset Batch Counter (904K) • 24 VDC to Power Peripherals

SPECIFICATIONS Display:

6-digit, 2-line, 7 segment LCD with sign

Preset:

Type 904 two preset values Type 903 one preset value

Supply voltage:

115 VAC, 230 VAC, 48 VAC or 24 VAC

Intellect-69 Series • High/Low Scaling from Front Panel • 2 Set Points Assignable To Rate or Total • Display Rate (Pressure, Level, Watts, Etc.), Peak and Valley and Integrated Total • 0–5V, 0–10V, 1–5V, 4–20 mA or 0–20 mA Analog Input • NEMA 4X/IP 65 Front Panel • +24V Output for Peripherals • RS-422/RS-232 Serial Communications • 4–20 mA Output • Square Root Extraction • Optional Rate Per Day Feature

ORDERING INFORMATION

(tolerance ± 10%) or 11 to 30 VDC Housing:

48 x 48 mm DIN

Protection:

IP 65 (front)

Power Supply:

24 VDC, 80 mA

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: INT69RT-A-L-1-A-C1 A – B – C – D – E

A

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number Order Example: 904K-A-0-A A – B – C – D

A

B

C

D

Basic Unit 903K Single Output 904K Dual Outputs Input Voltage A 115 VAC B 230 VAC C 11 to 30 VDC D 24 VAC E 48 VAC Outputs 0 Relay 1 Opto-Isolated collector and emitter Options — Blank if None A Backlit LCD Display (904K only)

B

C

D

E

Basic Unit INT69RT INT69R INT69PM2

Ratemeter/Totalizer Ratemeter Only Process Monitor Displays from -19999 to +49999 INT69T Totalizer Only Operating Voltage A 110 VAC ±15% or 12 to 24 VDC B 220 VAC ±15% or 12 to 24 VDC Inputs — Blank for INT69PM2 L Linear (standard) S Square Law (optional) Control Outputs 1 2-Open Collector Outputs (standard) 2 2–10 Amp Form C Relays (optional) Options (Multiple Options Available) A Analog Output (4–20 mA) D Rate per Day, Hour or Minute C1 RS-232 communications C2 RS-422 communications

42a


KEP Totalizer/Rate Meter

Newport 6-Digit Rate Meter/Totalizer

Low Cost, Pulse Input, Totalizer & Ratemeter

6-digit ratemeter/totalizer offers user programming via the 5 front-panel keys. Scale factor may be programmed from -99,999 to 999,999 (any decimal point, multiply or divide), while offset may be programmed from -99,999 to 999,999 (any decimal point).

Programs are stored in non-volatile memory, INFCTRA with three levels of program lockout for security. Optional features include Hi or Lo setpoints for control or alarm, plus RS-232 communication. Fixed decimal point or autoranging is standard.

SPECIFICATIONS MINItrol Series • CSA Approved • Separate Scaling Factors for A and B Inputs • Display Rate and Total • Pulse Input—10 kHz Maximum • Security Lockout • RS-422/RS-232 Serial Communication • NEMA-4X/IP65 Front Panel • Separate Add/Subtract Simultaneous Inputs • Quadrature and U/D Direction Control Inputs • 30 mV Magnetic Pickup Inputs • 4–20 mA or 0–20 mA Analog Output

▲ MRT

Functions: Display: Inputs Type:

Rate and totalize selected by menu 6-digit, 7-segment red LED display

Level: Frequency: Excitation:

A – B – C – D

Accuracy: Setpoints: Alarm Outputs: Communication: Power: Dimensions/Weight:

A

Panel Cutout:

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: MRT-A-3-1

Basic Unit MRT 6-Digits, Counter/Ratemeter MC2 6-Digits, Counter Only MR2 5-Digits, Rate Only B Operating Voltage A 110 VAC ±15% or 12 to 15 VDC B 220 VAC ±15% or 12 to 15 VDC C 24 VAC ±15% or 12 to 15 VDC C Count Inputs 3 Standard, 4–30 VDC Simultaneous Inputs 3M Mag. Input, Input A Only, 30mV Input (Input B, 4–30V) 3MB Mag. Input, Inputs A and B, 30 mV input 5 4–30V Pulses on Input A, 4–30V Direction Control Input on Input B 5M 30 mV Pulses on Input A, 4–30V Direction Control Input on Input B 9 Quadrature, Accepts 4–30V Pulses 9MB Quadrature, Accepts 30 mV Pulses (A and B) D Control Outputs 1 RS-232 Communications 2 RS-422 Communications A Analog Output (4–20/0–20 mA) CE CE Approved Version NOTE: RS-232/RS-422 and analog output options can not be combined.

42b

Single input. TTL, CMOS, NPN open collector, contact closure and magnetic pickup compatible; selected by dip switch. Non-isolated Max. 60V; min. 25 mV rms 30 kHz maximum Regulated, 5.0, 8.2, or 12.5V selected by DIP switch, 100 mA max ± 1/2 LSD of total; 0.01% of the rate ± 1/2 LSD Two, optional Optional RS-232, analog output, optional 230 ±15% VAC 1.9" H x 3.8" W x 6" D (48 x 96 x 152 mm)/16 oz (454g) 1.8" H x 3.6" W (45 x 92 mm)

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: INFCTRA-0-1-1-0-R A – B – C – D – E

A B

C

D

E

F

– F

Basic Unit INFCTRA Power and Display 0 115 VAC, Red LED 1 230 VAC, Red LED 2 115 VAC, Green LED 3 230 VAC, Green LED Control Output 0 None 1 Dual 6 Amp Analog Output 0 None 1 Analog Output Serial Output 0 None 1 RS-232 Configuration R Ratemeter T Totalizer


Weschler Analog Switchboard Meters • High accuracy, full view design • Volts, amps, watts, vars, speed, frequency and power factor • High overload capacity • Military and Nuclear versions • Ultimate in reliability and performance • Special scales and calibration • Formerly Westinghouse brand

Type K-241 & 261 instruments are designed to achieve the ultimate in reliability and performance. These instruments are recommended for use on electric utility switchboards and industrial process control panels. Commercial instruments comply with ANSI Standard C39.1 for 1% class switchboard instruments. The Hi-Shock versions were developed to meet the special needs of U.S. Navy shipboard applications. They are also suitable for commercial, marine and industrial applications subjected to humid conditions or severe mechanical shocks.

TAUT-BAND SUSPENSION

ANALOG METERS

Type K-241 & 261 instruments, except those which rotate continuously, use taut-band suspension. The taut-band suspension has unique advantages over the conventional pivot and jewel movement: • It eliminates friction, giving better accuracy and almost perfect repeatability. • It gives top performance under adverse conditions of shock and vibration. • It reduces maintenance, thereby saving money throughout the lifetime of the instrument. • It assures longer life, reducing annual depreciation and replacement costs. • It has greater sensitivity, reducing power burdens on circuits being measured.

L KA241

FULL VIEW DESIGN To facilitate quick, accurate reading, even under adverse conditions, all K-241 instruments feature the Westinghouse ‘full view’ 250° design. The window is flat, reducing light reflection to minimize the need for a non-glare surface. The dial scale is beveled for a 60° viewing angle.

MODIFICATIONS AVAILABLE DIALS: • Black • Dual Scale • Special Colors, Legends • Weather resistant Cover

Types Available Function DC Microammeter DC Milliameter DC Ammeter DC Millivoltmeter DC Voltmeter AC Milliammeter AC Ammeter AC Voltmeter AC Frequency AC Frequency AC Frequency AC Power Factor AC Power Factor AC Synchroscope AC Wattmeter AC Varmeter AC Varmeter Rectifier Milliammeter Rectifier Ammeter Rectifier Voltmeter Resistance Thermometer Speed Indicator Synchrotie

Ranges 50µA to 1mA 1mA to 1A 1A to 50A 50mV to 1V 1V to 800V 10mA to 1A 1A to 20A 10V to 750V 50, 60 & 400Hz 50, 60 & 400Hz 395-405Hz 0-1-0 0.5-1-0.5 -0.1 to 10A 0.1 to 10A 0.1 to 10A 1mA to 1A 1A to 17A 5V to 600V All Popular Ranges 0-25, up to 13000pps 0-360°

See more information online at weschler.com/analog

43

Type Designation KX-241 Com & HI, 241 Com KX-241 Com & HI, 241 Com KX-241 Com & HI, 241 Com KX-241 Com & HI, 241 Com KX-241 Com & HI, 241 Com KA-241 Com & HI, 261 Com KA-241 Com & HI, 261 Com KA-241 Com & HI, 261 Com KX-241 Com & HI KR3-241 Com KR4-241 HI KI-241 Com & HI, 261 Com KJ-241 Com KI-241 Com & HI, 261 Com KP-241 Com & HI, 261 Com & HI KP-241 Com & HI, 261 Com&HI KV-241 Com & HI, 261 Com & HI KC-241 Com & HI, 261 Com KC-241 Com & HI, 261 Com KC-241 Com & HI, 261 Com KX-241 Com & HI, 261 Com KX-241 Com & HI, 261 Com KS-241 Com, Unmounted Transmitter

ELECTRICAL: • Intermediate Ratings • Special Calibrations • Offset or Suppressed Zero • Multiple Rating • Special Sensitivity Mechanism Permanent-magnet moving coil Permanent-magnet moving coil Permanent-magnet moving coil Permanent-magnet moving coil Permanent-magnet moving coil Iron Vane Iron Vane Iron Vane With Separate Transducer Self Contained Transducer Self Contained Transducer Rotating Vane Self Contained Transducer Rotating Vane Self Contained Transducer With External Phase Shifter Self Contained Transducer Permanent-magnet moving coil Permanent-magnet moving coil Permanent-magnet moving coi Self Contained Bridge Self Contained Transducer Self-Synchronous


Yokogawa Mini Switchboard Meters • Compact Size 3" Case • Rugged, Durable Construction • No Shadows on Scale • Accurate and Readable, Even from Sharp Angles • Accurate to Within ±1.5% of Full Scale • Attractive, Uncluttered Scales • Taut-Band Suspension

L

L

Mini Switchboard Series

2185

2182

SPECIFICATIONS

SPECIFICATIONS ±1.5% of FS basic accuracy class ±1.5% @ 25°C calibrated on sine 0–40°C (32°F–104°F) 2,600 VAC for 1 minute between circuit & case Voltmeter or potential coils—1.2x continuous; AC ammeters—2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds Position of Use Vertical (scale) Full Scale Deflection Angle/Length 250°/5.5” Case ABS resin, black Size (H x W x D) 3.18" x 3.18" x 4.35" Barrel (cutout) 2.84" Dia.

ORDERING INFORMATION AC/DC Amps, Volts and Frequency To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 218200-A42 (0-150)

In accordance with ANSI Specifications C39.1 Accuracy: Power Factor ±5% of scale length Accuracy: Watts/VARS ±1.5% of FS value Operating Temperature Range 0–40°C (32°F–104°F) Dielectric Level 2,600 VAC for 1 minute between circuit & case NOTE: All units supplied with external transducers. Except balanced Power Factor Meter.

ORDERING INFORMATION Watt, Var & Power Factor To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 2185-34-W56 A – B – C

Basic Unit

A

2185 2186 2187

Function/Connection Watts

B

A – B A

B

31 34 35 36

Basic Unit 218100 218200 218830

DC Ammeters and Voltmeters AC Ammeters and Voltmeters Frequency Meters DC Voltmeter VNL 30 VDC VNT 50 VDC VPK 100 VDC VPZ 150 VDC VRX 300 VDC V01 1 mADC 3510-50 mADC 364-20 mADC 371-5 VDC

AC Ammeter

AC Voltmeter

AKG AKM ALA ALC ALS A42 AMF AMT ANL

VPK 100 VAC VPZ 150 VAC V12 150 VAC(for PT) VRX 300 VAC VSI 600 VAC V20 70-130 VAC* V21 140-260 VAC* * Expanded Scale

300 mAAC 500 mAAC 1 AAC 1.5 AAC 5 AAC 5 AAC (for CT) 7.5 AAC 10 AAC 30 AAC

Frequency Meter H40 H41 H42

115V 45-55 Hz 115V 55-65 Hz 115V 45-65 Hz

H60 H61 H62

230V 45-55 Hz 230V 55-65 Hz 230V 45-65 Hz

Single Phase Three Phase, Four Wire Three Phase, Three Wire-Unbalanced Three Phase, Four Wire-Unbalanced

Vars 31 33 34 35 36

Rating and Scale DC Ammeter AKM 500 mADC ALA 1 ADC ALS 5 ADC AMT 10 ADC AND 15 ADC ANG 20 ADC ANL 30 ADC A01 50 mVDC A05 100 mVDC

AC Wattmeters AC Varmeters AC Power Factor Meter

Single Phase Three Phase, Three Wire Three Phase, Four Wire Three Phase, Three Wire-Unbalanced Three Phase, Four Wire-Unbalanced

Power Factor 31 33 35 36 C

Single Phase Three Phase, Three Wire Three Phase, Three Wire-Unbalanced Three Phase, Four Wire-Unbalanced

Input Watts

W55 120V-1A AC W56 120V-5A AC W65 240V-1A AC W66 240V-5A AC

VARs M55 M56 M65 M66

120V-1A AC 120V-5A AC 240V-1A AC 240V-5A AC

Power Factor C55 C56 C65 C66

120V-1A AC 120V-5A AC 240V-1A AC 240V-5A AC

OPTIONS (WHERE APPLICABLE) Custom Scaling Nonstandard Ranges Adjustable Potentiometer (Voltmeters Only) Color Bands

44

ANALOG METERS

Accuracy Rectifier Instruments Operating Temperature Range Dielectric Level Overload Rating


Yokogawa DC Current and Voltage Switchboard Meters DB Series • No Shadows on Scale • Accurate and Readable • Accurate to Within ±1% FS • High-Shock Design Meets MIL-M-16034A and MIL-S-901 (DB-14) • Weathertight Construction Ideal for Adverse Conditions (DB-40) • Easy to Read Up to 30 Feet Away • Taut-Band Suspension DB-40

DC PROCESS INPUTS

ANALOG METERS

SPECIFICATIONS In accordance with ANSI Specifications C39.1 Input ±1% of FS basic accuracy class Rectifier Instruments ±112⁄ % @ 25°C calibrated on sine wave Operating Temperature Range 0–40°C (32°F–104°F) Dielectric Level 2,300 VAC for 1 minute between circuit and case Overload Rating Voltmeter or potential coils—1.2x continuous; AC ammeters—2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB-16) Position of Use Vertical (Scale) Full Scale Deflection Angle 250° Case Size 414⁄ " 414⁄ " 834⁄ " Model DB-14 DB-40 DB-16 Size (H x W x D) 4.33" x 4.33" x 4.85" 8.69" x 8.69" x 4.85" Barrel (cutout) 4.03" 4.03" Full Scale Length

6.9"

L

Scale and Rating

DB-14 Cat. No.

10-50 101 193 HX** 4-20 101 193 HE** 1-5 101 193 FY** DC Ammeters 0-1 101 113 LALA 0-5 101 113 LSLS 0-10 101 113 MTMT 0-15 101 113 NDND 0-20 101 113 NGNG 0-30 101 113 NLNL *Specify scale values

DB-40 Cat. No.

DB-16 Cat. No.

103 191 HX** 103 191 HE** 103 191 FY**

121 191 HX** 121 191 HE** 121 191 FY**

103 111 LALA 103 111 LSLS 103 111 MTMT 103 111 NDND 103 111 NGNG 103 111 NLNL

121 111 LALA 121 111 LSLS 121 111 MTMT 121 111 NDND 121 111 NGNG 121 111 NLNL

13.8"

DC AMMETERS - SHUNT RATED (50MVDC)

DC VOLTS Scale and Rating

DB-14 Cat. No.

DB-40 Cat. No.

DB-16 Cat. No.

Scale (Amps)

DB-14 Cat. No.

DB-40 Cat. No.

DB-16 Cat. No.

0-15 0-30 0-50 0-75 0-150 0-300 0-400 0-500 0-600 150-0-150 300-0-300 500-0-500 600-0-600

101 013 NDND 101 013 NLNL 101 013 NTNT 101 013 PBPB 101 013 PZPZ 101 013 RXRX 101 013 SCSC 101 013 SFSF 101 013 SJSJ 101 014 PZPZ 101 014 RXRX 101 014 SFSF 101 014 SJSJ

103 011 NDND 103 011 NLNL 103 011 NTNT 103 011 PBPB 103 011 PZPZ 103 011 RXRX 103 011 SCSC 103 011 SFSF 103 011 FJFJ 103 012 PZPZ 103 012 RXRX 103 012 SFSF 103 012 SJSJ

121 011 NDND 121 011 NLNL 121 011 NTNT 121 011 PBPB 121 011 PZPZ 121 011 RXRX 121 011 SCSC 121 011 SFSF 121 011 SJSJ 121 012 PZPZ 121 012 RXRX 121 012 SFSF 121 012 SJSJ

0-15 0-20 0-30 0-40 0-50 0-75 0-100 0-150 0-200 0-300 0-400 0-500 0-750 0-1000 0-1200 0-1500 0-2000 0-3000

101 123 CAND 101 123 CANG 101 123 CANL 101 123 CANP 101 123 CANT 101 123 CAPB 101 123 CAPK 101 123 CAPZ 101 123 CARL 101 123 CARX 101 123 CASC 101 123 CASF 101 123 CASM 101 123 CASS 101 123 CASV 101 123 CATC 101 123 CATM 101 123 CAUA

103 121 CAND 103 121 CANG 103 121 CANL 103 121 CANP 103 121 CANT 103 121 CAPB 103 121 CAPK 103 121 CAPZ 103 121 CARL 103 121 CARX 103 121 CASC 103 121 CASF 103 121 CASM 103 121 CASS 103 121 CASV 103 121 CATC 103 121 CATM 103 121 CAUA

121 121 ECND 121 121 ECNG 121 121 ECNL 121 121 ECNP 121 121 ECNT 121 121 ECPB 121 121 ECPK 121 121 ECPZ 121 121 ECRL 121 121 ECRX 121 121 ECSC 121 121 ECSF 121 121 ECSM 121 121 ECSS 121 121 ECSV 121 121 ECTC 121 121 ECTM 121 121 ECUA

OPTIONS Custom Scaling Nonstandard Ranges Adjustable Potentiometer (Voltmeters Only) Color Bands Illumination

45


Yokogawa AC Current Switchboard Meters SPECIFICATIONS

AB Series • Rugged, Durable Construction • No Shadows on Scale • Accurate and Readable Even from Sharp Angles • Accurate to Within ±1% of Full Scale • Attractive, Uncluttered Scales • High-Shock Design Meets MIL-M-16034A and MIL-S-901 (AB-14) • Weathertight Construction Ideal for Adverse Conditions (AB-40) • Easy to Read Up to 30 Feet Away (AB-16) • Taut-Band Suspension

In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ±112⁄ % @ 25°C calibrated on sine wave Operating Temperature Range 0–40°C (32°F–104°F) Dielectric Level 2,300 VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils— 1.2x continuous; AC ammeters— 2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB-16) Position of Use Vertical (scale) Full Scale Deflection Angle 250° Case Size 414⁄ " 414⁄ " 834⁄ " Model AB-14 AB-40 AB-16 Size (H x W x D) 4.33" x 4.33" x 4.85" 8.69" x 8.69" x 4.85" Barrel (cutout) 4.03" Full Scale Length 6.9" 13.8"

AB-16

AB-40

AB-14

OPTIONS Custom Scaling Nonstandard Ranges Color Bands Illumination

L

L

L

Photos not to scale

AB-14 Cat. No. 101 133 LALA 101 133 LCLC 101 133 LELE 101 133 LJLJ 101 133 LSLS 101 133 MFMF 101 133 MTMT 101 133 NDND 101 133 NGNG 101 133 NLNL

AB-40 Cat. No. 103 131 LALA 103 131 LCLC 103 131 LELE 103 131 LJLJ 103 131 LSLS 103 131 MFMF 103 131 MTMT 103 131 NDND 103 131 NGNG 103 131 NLNL

AB-16 Cat. No. 121 131 LALA 121 131 LCLC 121 131 LELE 121 131 LJLJ 121 131 LSLS 121 131 MFMF 121 131 MTMT 121 131 NDND 121 131 NGNG 121 131 NLNL

101 133 LSMT 101 133 LSND 101 133 LSNG 101 133 LSNJ 101 133 LSNL 101 133 LSNP 101 133 LSNT 101 133 LSPB 101 133 LSPK 101 133 LSPZ 101 133 LSRL 101 133 LSRS 101 133 LSRX 101 133 LSSC 101 133 LSSF 101 133 LSSJ 101 133 LSSN 101 133 LSSS 101 133 LSSV 101 133 LSTC 101 133 LSTM 101 133 LSTV 101 133 LSUA 101 133 LSUE 101 133 LSUJ 101 133 LSUP 101 133 LSUS 101 133 LSUW

103 131 LSMT 103 131 LSND 103 131 LSNG 103 131 LSNJ 103 131 LSNL 103 131 LSNP 103 131 LSNT 103 131 LSPB 103 131 LSPK 103 131 LSPZ 103 131 LSRL 103 131 LSRS 103 131 LSRX 103 131 LSSC 103 131 LSSF 103 131 LSSJ 103 131 LSSN 103 131 LSSS 103 131 LSSV 103 131 LSTC 103 131 LSTM 103 131 LSTV 103 131 LSUA 103 131 LSUE 103 131 LSUJ 103 131 LSUP 103 131 LSUS 103 131 LSUW

121 131 LSMT 121 131 LSND 121 131 LSNG 121 131 LSNJ 121 131 LSNL 121 131 LSNP 121 131 LSNT 121 131 LSPB 121 131 LSPK 121 131 LSPZ 121 131 LSRL 121 131 LSRS 121 131 LSRX 121 131 LSSC 121 131 LSSF 121 131 LSSJ 121 131 LSSN 121 131 LSSS 121 131 LSSV 121 131 LSTC 121 131 LSTM 121 131 LSTV 121 131 LSUA 121 131 LSUE 121 131 LSUJ 121 131 LSUP 121 131 LSUS 121 131 LSUW

46

ANALOG METERS

ORDERING INFORMATION Self-Contained, 40/70 Hz Rating Scale (amperes) (amperes) 1 0-1 1.5 0-1.5 2 0-2 3 0-3 5 0-5 7.5 0-7.5 10 0-10 15 0-15 20 0-20 30 0-30 Transformer-Rated, 40/70 Hz 5 0-10 5 0-15 5 0-20 5 0-25 5 0-30 5 0-40 5 0-50 5 0-75 5 0-100 5 0-150 5 0-200 5 0-250 5 0-300 5 0-400 5 0-500 5 0-600 5 0-800 5 0-1000 5 0-1200 5 0-1500 5 0-2000 5 0-2500 5 0-3000 5 0-4000 5 0-5000 5 0-6000 5 0-7000 5 0-8000


Yokogawa AC Voltage Switchboard Meters AB Series • Rugged, Durable Construction • No Shadows on Scale • Accurate and Readable, Even from Sharp Angles • Accurate to Within ±1% of Full Scale • Attractive, Uncluttered Scales • High-Shock Design Meets MIL-M-16034A and MIL-S-901 (AB-14) • Weathertight Construction Ideal for Adverse Conditions (AB-40) • Easy to Read Up to 30 Feet Away (AB-16) • Taut-Band Suspension

47

ANALOG METERS

AB-16 Cat. No. 121 021 PZPZ 121 021 RSRS 121 021 RXRX 121 021 SFSF 121 021 SJSJ 121 021 SMSM 121 021 PZRX 121 021 PZSJ 121 021 PZSM 121 021 PZUA 121 021 PZUL 121 021 PZUY 121 021 PZWZ 121 021 PZXE 121 021 PZXU 121 021 PZYR 121 021 RSSJ 121 071 PNPN 121 071 PN..+ + + + + + + 121 021 PZPZ 121 021 PZ..+ 121 021 RXRX 121 021 SJSJ

AB-16

L

SPECIFICATIONS In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ±112⁄ % @ 25°C calibrated on sine wave Operating Temperature Range 0–40°C (32°F–104°F) Dielectric Level 2,300VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils— 1.2x continuous; AC ammeters— 2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB-16) Position of Use Vertical (scale) Full Scale Deflection Angle 250° Case Size 414⁄ " 414⁄ " 834⁄ " Model AB-14 AB-40 AB-16 Size (H x W x D) 4.33" x 4.33" x 4.85" 8.69" x 8.69" x 4.85" Barrel (cutout) 4.03" Full Scale Length 6.9" 13.8"

OPTIONS Custom Scaling Nonstandard Ranges Adjustable Potentiometer (Voltmeters Only) Color Bands Illumination (Red or White)

L

* UL Version Not Available ** High Stock Version Not Available + Order by Description. Specify P.T. (Potential Transformer) Ratio if Used, and Scale Desired.

L

Photos not to scale

ORDERING INFORMATION Self-Contained, 50/60 Hz Rating Scale AB-14 AB-40 (volts) Volts Cat. No. Cat. No. 150 0-150 101 023 PZPZ 103 021 PZPZ 250 0-250 101 023 RSRS 103 021 RSRS 300 0-300 101 023 RXRX 103 021 RXRX 500 0-500 101 023 SFSF 103 021 SFSF 600 0-600 101 023 SJS 103 021 SJSJ 750* 0-750* ** 103 021 SMSM Transformer-Rated, 50/60 Hz 150 0-300 101 023 PZRX 103 021 PZRX 150 0-600 101 023 PZSJ 103 021 PZSJ 150 0-750 101 023 PZSM 103 021 PZSM 150 0-3000 101 023 PZUA 103 021 PZUA 150 0-5250 101 023 PZUL 103 021 PZUL 150 0-9000 101 023 PZUY 103 021 PZUY 150 0-15kV 101 023 PZWZ 103 021 PZWZ 150 0-18kV 101 023 PZXE 103 021 PZXE 150 0-45kV 101 023 PZXU 103 021 PZXU 150 0-150kV 101 023 PZYR 103 021 PZYR 250 0-600 101 023 RSSJ 103 021 RSS Expanded Scale Self-Contained, 50/60 Hz 110-130 110-130 ** 103 071 PNPN Expanded Scale Transformer-Rated, 50/60 Hz 110-130 + ** 103 071 PN..+ Rectifier-Type 1.5% 20-3000 Hz 15 0-15 ** + 30 0-30 ** + 150 0-150 ** + 150 + ** + 300 0-300 ** + 600 0-600 ** + Ground-Detector Type-Single-Phase 50/60 Hz 150 0-150 ** 103 021 PZPZ 150 + ** 103 021 PZ..+ 300 0-300 ** 103 021 RXRX 600 0-600 ** 103 021 SJSJ

AB-40

AB-40 with Red Illumination


Yokogawa AC Watt & VAR Switchboard Meters • • • • • • • •

Rugged, Durable Construction No Shadows on Scale Accurate and Readable, Even from Sharp Angles Accurate to Within ±1% of Full Scale Attractive, Uncluttered Scales Weathertight Construction Ideal for Adverse Conditions (AB-40) Easy to Read Up to 30 Feet Away (AB-16) Taut-Band Suspension

SPECIFICATIONS

VAR METER ORDERING INFORMATION Rating (Amperes) Rating (Volts) Scale AB-40 Cat. No. AB-16 Cat. No. Single Phase/2-Wire, 1-Element, Transformer Rated, 60 Hz 5 120 † 103 31KA… 121 31KA… 5 120 † 103 762 A…* 121 762A…* 3-Phase/3-Wire, 2-Element, Transformer Rated, 50/60 Hz (Cannot Use with External Phase Shifter) 5 120 † 103 28KA… 121 28KA… 5 120 † 103 812A…• 121 812A…• 3-Phase, 3-Wire, 2-Element, Transformer-Rated, 60 Hz for Use with External Phase Shifters 5 120 † 103 32KA… 121 32KA… 5 120 † 103 772A…* 121 772A…* 3-Phase/4-Wire, 21⁄2-Element, Transformer-Rated, 50/60 Hz (Cannot Use External Phase Shifter) 5 208$ † 103 29KB… 121 29KB… 5 208$ † 103 742B…L 121 742B…L 3-Phase/4-Wire, 21⁄2-Element, Transformer-Rated, 60 Hz for Use with External Phase Shifters 5 120 † 103 34KA… 121 34KA… 5 120 † 103 792A…* 121 792A…* † Order by description. Specify CT (Current Transformer) and/or PT (Potential Transformer) ratios if used and scale desired. * Used for 0-Center when calibrating watts are less than ±380. • Used for 0-Center when calibrating watts less than ±658. L Used for 0-Center when calibrating watts are less than ±760. $ The 21⁄2-element varmeters used on 4-wire 3-phase 120V L-N systems are rated 208V because they are connected line-to-line. K Sixth digit signifies pointer deflection (1-zero left, 2-zero center).

L

L

AB-16

AB-40 Photos not to scale

WATT METER ORDERING INFORMATION AC Wattmeters Non-Isolated (cannot be use with external phase shifter for VARs)

Single-Phase/2-Wire, 1-Element, Self-Contained, 50/60 Hz Rating Scale AB-40 AB-16 Amperes/Volts Cat. No. Cat. No. 1.25 120 0-125 Watts 103 211AARC7GCB 121 211AARC7GCB 2.50 120 0-250 Watts 103 211AAWP7CJB 121 211AAWP7CJB 5 120 0-500 Watts 103 211ARBU7CRB 121 211ARBU7CRB 10 120 0-1000 Watts 103 211AWDP7DAB 121 211AWDP7DAB Single-Phase/2-Wire, 1-Element, Transformer-Rated, 50/60 Hz 5 120 + 103 21KA…… 121 21KA…… 3-Phase/3-Wire, 2-Element, Transformer-Rated, 50/60 Hz 5 120 103 22KA…… 121 22KA…… 5 240 + 103 22KC…… 121 22KC…… 5 480* 103 22KD…… 121 22KD…… 5 600* 103 22KE…… 121 22KE…… 3-Phase/4-Wire, 21⁄2-Element, Transformer-Rated, 50/60 Hz (voltage balanced) 5 69 103 25KF…… 121 25KF…… 5 120 + 103 25KA…… 121 25KA…… 5 240 103 25KC…… 121 25KC…… + Order by Description. Specify CT (Current Transformer) and/or PT (Potential Transformer) Ratios if Used, and Scale Desired. * UL Version in Short Case, Non-UL Version in Long Case. K Sixth Digit Signifies Pointer Deflection (1-Zero Left, 2-Zero Center)

OPTIONS (WHERE APPLICABLE) Custom Scaling Nonstandard Ranges Zero-Center Color Bands Nonstandard Frequencies

48

ANALOG METERS

In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ±112⁄ % @ 25°C calibrated on sine wave Operating Temperature Range 0–40°C (32°F–104°F) Dielectric Level 2,300VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils—1.2x continuous; AC ammeters—2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB-16) Position of Use Vertical (scale) Full Scale 250° (360° for synchroscopes) Deflection Angle Case Size 414⁄ " 834⁄ " Model AB-40 AB-16 Size (H x W x D) 4.33" x 4.33" x 4.85" 8.69" x 8.69" x 4.85" Barrel (cutout) 4.03" Full Scale Length 6.9" 13.8"


Yokogawa Power Factor, Frequency & Synchroscope Meters • Rugged, Durable Construction • No Shadows on Scale • Accurate and Readable, Even from Sharp Angles • Accurate to Within ±1% of Full Scale • Attractive, Uncluttered Scales

L

• Weathertight Construction Ideal for Adverse Conditions (AB-40)

AB-16

• Easy to Read up to 30 Feet Away (AB-16)

ORDERING INFORMATION Power Factor AB-40 Amperes Volts Scale Cat. No. Single-Phase 2 Wire 60 Hz 5 120 .5-1-.5 103 412 FCAD 3-Phase 3 & 4 Wire, 50 & 60 Hz, Balanced System Only 5 120 .5-1-.5 103 402 FCAD 5 208* .5-1-.5 103 402 CCAD 5 240 .5-1-.5 103 402 FEAD 5 480 .5-1-.5 103 402 FFAD 5 600 .5-1-.5 103 402 FGAD 3-Phase 3 Wire, 50/60 Hz, Unbalanced Systems 5 120 .5-1-.5 103 462 FCAD 5 240 .5-1-.5 103 462 FEAD 3-Phase 4-Wire, 50/60 Hz, Unbalanced Systems 5 120+ .5-1-.5 103 472 FCAD 5 208+ .5-1-.5 103 472 CCAD 5 240++ .5-1-.5 103 472 FEAD Frequency Meters, 120V Rated Scale Center AB-40 (Hz) Freq, Hz Cat. No. 45-55 50 103 372 AGAG 45-65 55 103 372 AJAJ 48-52 50 103 372 AKAK 50-70 60 103 372 ALAL 55-65 60 103 372 ANAN 58-62 60 103 372 ATAT 59-61 60 103 372 ASAS 350-450 400 103 372 BHBH 390-410 400 103 372 BLBL Synchroscopes—Pivot and Jewel—120 Volt Rated Scale Normal AB-40 Freq. Cat. No. Slow-Fast 50 106 452 ABAA Slow-Fast 60 106 452 AAAA Slow-Fast 400 106 452 ACAA * Line to line 208V (120V line to neutral) + Line to line ++ Line to neutral

49

AB-16 Cat. No. 121412 FCAD 121 402 FCAD 121 402 CCAD 121 402 FEAD 121 402 FFAD 121 402 FGAD — — — — — AB-16 Cat. No. 121 372 AGAG 121 372 AJAJ 121 372 AKAK 121 372 ALAL 121 372 ANAN 121 372 ATAT 121 372 ASAS 121 372 BHBH 121 372 BLBL AB-16 Cat. No. 120 452 ABAA 120 452 AAAA 120 452 ACAA

L

ANALOG METERS

• Taut-Band Suspension Except Synchroscopes

AB-40

SPECIFICATIONS In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ±112⁄ % @ 25°C calibrated on sine wave Power Factor Meters ±1% of scale length Balanced system (20-100% rated current) Unbalanced system (±3% of scale length) Frequency Meters 45 Hz–55 Hz, ±0.15 Hz 55 Hz–66 Hz, ±0.15 Hz 58 Hz–62 Hz, ±0.093 Hz 350 Hz–450 Hz, ±1.5 Hz Operating Temperature Range 0–40°C (32°F–104°F) Dielectric Level 2,300 VAC for 1 minute between circuit and case Overload Rating Voltmeter or potential coils, 1.2x continuous AC ammeters, 2x continuous, 10x for 1 second. Current coils other than AC ammeters, 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB/DB-16) Position of Use Vertical (scale) Full Scale Deflection Angle 250° Case Size Model Size (H x W x D) Barrel (Cutout) Scale Length 414⁄ " AB-14 4.33" x 4.33" x 6.75" 4.03" 6.9" 414⁄ " AB-40 4.33" x 4.33" x 6.75" 4.03" 6.9" 834⁄ " AB-16 8.69" x 8.69" x 6.75" 4.03" 13.8"


Yokogawa Dual Display Meters

NEW ORDERING INFORMATION (CONT'D)

Dual-Vue • Taut Band Movement • 0.56" 31/2 Digit Display • High Intensity Red, Green or Blue LEDs • Switchboard Case with IP54 Front

SPECIFICATIONS Input Impedance: Input Burden:

Dial: Digital Display: Analog Accuracy: Digital Accuracy: Overload:

Operating Temperature: Storage Temperature: Size:

OPTIONS Custom scale Custom legend Black dial Digital scale different from analog 240VAC power supply DC power supply

Red LED Cat. No.

0-50mV 0-100mV 0-200mV 50-0-50mV 100-0-100mV 200-0-200mV 0-10V 0-100V 0-150V 0-300V 0-600V 10-0-10V 100-0-100V 150-0-150V 300-0-300V 600-0-600V

123011ABAB 123011AEAE 123011 AHAH 123012 ABAB 123012AEAE 123012AHAH 123011MTMT 123011PKPK 123011PZPZ 123011RXRX 123011SJSJ 123012MTMT 123012PKPK 123012PZPZ 123012RXRX 123012SJSJ

0-200uA 0-500uA 200-0-200uA 500-0-500uA 0-1mA 0-10mA 0-100mA 0-500mA 0-1A 1-0-1mA 10-0-10mA 100-0-100mA 500-0-500mA 1-0-1A 1-5mA 4-20mA 10-50mA

123111EAEA 123111EMEM 123112EAEA 123112EMEM 123111FAFA 123111GZGZ 123111JRJR 123111KMKM 123111LALA 123112FAFA 123112GZGZ 123112JRJR 123112KMKM 123112LALA 123191FYFY 123191HEHE 123191HXHX

0-150V 0-250V 0-300V 0-600V 0-150V/0-250V 0-150V/0-300V 0-150V/0-500V 0-150V/0-600V 0-150V/0-750V 0-150V/0-1500V 0-150V/0-3.00kV 0-150V/0-5.00kV 0-150V/0-5.25kV 0-150V/0-6.00kV 0-150V/0-9.00kV 0-150V/0-15.00kV 0-150V/0-18.00kV 0-150V/0-45.0kV 0-150V/0-150.0kV 0-150V/0-200kV 0-250V/0-600V 0-1A 0-5A

ORDERING INFORMATION Input Rating/ Scale

Red LED Cat. No.

Green LED Cat. No.

Blue LED Cat. No.

124011ABAB 124011AEAE 124011 AHAH 124012 ABAB 124012AEAE 124012AHAH 124011MTMT 124011PKPK 124011PZPZ 124011RXRX 124011SJSJ 124012MTMT 124012PKPK 124012PZPZ 124012RXRX 124012SJSJ

125011ABAB 125011AEAE 125011 AHAH 125012 ABAB 125012AEAE 125012AHAH 125011MTMT 125011PKPK 125011PZPZ 125011RXRX 125011SJSJ 125012MTMT 125012PKPK 125012PZPZ 125012RXRX 125012SJSJ

DCV

0-5A/0-10.00A 0-5A/0-15.00A 0-5A/0-20.0A 0-5A/0-25.0A 0-5A/0-30.0A 0-5A/0-40.0A 0-5A/0-50.0A 0-5A/0-75.0A 0-5A/0-100.0A 0-5A/0-150.0A 0-5A/0-200A 0-5A/0-250A 0-5A/0-300A 0-5A/0-400A 0-5A/0-500A 0-5A/0-600A 0-5A/0-800A 0-5A/0-1000A 0-5A/0-1200A 0-5A/0-1500A

Green LED Cat. No.

DCA 124111EAEA 124111EMEM 124112EAEA 124112EMEM 124111FAFA 124111GZGZ 124111JRJR 124111KMKM 124111LALA 124112FAFA 124112GZGZ 124112JRJR 124112KMKM 124112LALA 124191FYFY 124191HEHE 124191HXHX ACV 123021PZPZ 124021PZPZ 123021RSRS 124021RSRS 123021RXRX 124021RXRX 123021SJSJ 124021SJSJ ACV Transformer Rated (150V) 123021PZRS 124021PZRS 123021PZRX 124021PZRX 123021PZSF 124021PZSF 123021PZSJ 124021PZSJ 123021PZSM 124021PZSM 123021PZTC 124021PZTC 123021PZVJ 124021PZVJ 123021PZVT 124021PZVT 123021PZVV 124021PZVV 123021PZVX 124021PZVX 123021PZWJ 124021PZWJ 123021PZWZ 124021PZWZ 123021PZXE 124021PZXE 123021PZXU 124021PZXU 123021PZYR 124021PZYR 123021PZYU 124021PZYU 123021RSSJ 124021RSSJ ACA 123131LALA 124131LALA 123131LSLS 124131LSLS ACA Transformer Rated (5A) 123131LSMT 124131LSMT 123131LSND 124131LSND 123131LSNG 124131LSNG 123131LSNJ 124131LSNJ 123131LSNL 124131LSNL 123131LSNP 124131LSNP 123131LSNT 124131LSNT 123131LSPB 124131LSPB 123131LSPK 124131LSPK 123131LSPZ 124131LSPZ 123131LSRL 124131LSRL 123131LSRS 124131LSRS 123131LSRX 124131LSRX 123131LSSC 124131LSSC 123131LSSF 124131LSSF 123131LSSJ 124131LSSJ 123131LSSN 124131LSSN 123131LSSS 124131LSSS 123131LSSV 124131LSSV 123131LSTC 124131LSTC

Blue LED Cat. No. 125111EAEA 125111EMEM 125112EAEA 125112EMEM 125111FAFA 125111GZGZ 125111JRJR 125111KMKM 125111LALA 125112FAFA 125112GZGZ 125112JRJR 125112KMKM 125112LALA 125191FYFY 125191HEHE 125191HXHX 125021PZPZ 125021RSRS 125021RXRX 125021SJSJ 125021PZRS 125021PZRX 125021PZSF 125021PZSJ 125021PZSM 125021PZTC 125021PZVJ 125021PZVT 125021PZVV 125021PZVX 125021PZWJ 125021PZWZ 125021PZXE 125021PZXU 125021PZYR 125021PZYU 125021RSSJ 125131LALA 125131LSLS 125131LSMT 125131LSND 125131LSNG 125131LSNJ 125131LSNL 125131LSNP 125131LSNT 125131LSPB 125131LSPK 125131LSPZ 125131LSRL 125131LSRS 125131LSRX 125131LSSC 125131LSSF 125131LSSJ 125131LSSN 125131LSSS 125131LSSV 125131LSTC

50

ANALOG METERS

Input Frequency: Power Supply:

1MΩ on DCV & ACV <210mV for inputs <500mA DC, <510mV for inputs >500mA DC ACA <0.2VA @ 5AAC; ACV <0.5VA @ 600V 45Hz to 65Hz on ACV & ACA 120VAC ±15%, 50/60Hz ±2Hz, <3.5VA standard; White scale with black markings & black pointer (standard). -1999 to 1999 with selectable decimal ±1% of full scale deflection at 25°C AC ±0.1% of reading ±3 counts at 25°C. DC ±2 counts DCV & ACV: continuous 1.2x or 700V max.; 1.5x for 10sec DC Current: continuous 1.2x; 1.5x for 5sec AC Current: continuous 2x; 5x for 10sec 0°C to 60°C, <90% RH @40°C -20°C to 70°C 4.33" x 4.33" x 5.0"Deep

Input Rating/ Scale


Crompton Switchboard Meters • 250° Linear Scale • AC Instruments with True RMS Circuit • Oil Dampened Mechanisms

• IP54 Front • UL/CSA Approvals • Optional Terminal Cover (007 Case)

AC/DC SWITCHBOARD METER SPECIFICATIONS ±1% Full Scale Approx. 2.5 Seconds to Full Scale 250° Full Scale Deflection Vertical (Scale) 33% Maximum 2300 VAC for 1 Minute -20°C to 65°C 4.30" x 4.30" x 2.20" (007 case) 4.30" x 4.30" x 3.40" (077 case) 9.02" x 9.02" x 4.6" (079 case)

L

ANALOG METERS

Accuracy: Response Time: Scale Arc: Position Use: Overshoot: Dielectric Withstand: Operating Temperature: Size (H x W x D, including studs):

077

AC AMMETERS - RMS READING SELF CONTAINED 4 1/2" Square Flange Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 1A 0-1A K-05FA-LALA-C6 078-05FJ-LALA-C6 1.5A 0-1.5A K-05FA-LCLC-C6 078-05FJ-LCLC-C6 2A 0-2A K-05FA-LELE-C6 078-05FJ-LELE-C6 3A 0-3A K-05FA-LJLJ-C6 078-05FJ-LJLJ-C6 5A 0-5A K-05FA-LSLS-C6 078-05FJ-LSLS-C6 7.5A 0-7.5A K-05FA-MFMF-C6 078-05FJ-MFMF-C6 10A 0-10A K-05FA-MTMT-C6 078-05FJ-MTMT-C6 15A 0-15A K-05FA-NDND-C6 078-05FJ-NDND-C6 20A 0-20A K-05FA-NGNG-C6 078-05FJ-NGNG-C6 30A 0-30A K-05FA-NLNL-C6 078-05FJ-NLNL-C6 K Insert 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

4 1/2" Square Flange Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 150V 0-150V K-05GA-PZPZ-C6 078-05GJ-PZPZ-C6 250V 0-250V K-05GA-RSRS-C6 078-05GJ-RSRS-C6 300V 0-300V K-05GA-RXRX-C6 078-05GJ-RXRX-C6 500V 0-500V K-05GA-SFSF-C6 078-05GJ-SFSF-C6 600V 0-600V K-05GA-SJSJ-C6 078-05GJ-SJSJ-C6 750V 0-750V K-05GA-SMSM-C6 078-05GJ-SMSM-C6 K Insert 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

AC AMMETERS - RMS READING TRANSFORMER RATED

AC VOLTMETERS - RMS READING TRANSFORMER RATED

5A 0-10A K-05FA-LSMT-C6 078-05FJ-LSMT-C6 5A 0-15A K-05FA-LSND-C6 078-05FJ-LSND-C6 5A 0-20A K-05FA-LSNG-C6 078-05FJ-LSNG-C6 5A 0-25A K-05FA-LSNJ-C6 078-05FJ-LSNJ-C6 5A 0-30A K-05FA-LSNL-C6 078-05FJ-LSNL-C6 5A 0-40A K-05FA-LSNP-C6 078-05FJ-LSNP-C6 5A 0-50A K-05FA-LSNT-C6 078-05FJ-LSNT-C6 5A 0-75A K-05FA-LSPB-C6 078-05FJ-LSPB-C6 5A 0-100A K-05FA-LSPK-C6 078-05FJ-LSPK-C6 5A 0-150A K-05FA-LSPZ-C6 078-05FJ-LSPZ-C6 5A 0-200A K-05FA-LSRL-C6 078-05FJ-LSRL-C6 5A 0-250A K-05FA-LSRS-C6 078-05FJ-LSRS-C6 5A 0-300A K-05FA-LSRX-C6 078-05FJ-LSRX-C6 5A 0-400A K-05FA-LSSC-C6 078-05FJ-LSSC-C6 5A 0-500A K-05FA-LSSF-C6 078-05FJ-LSSF-C6 Note: Additional meters with scales up to 8,000A available K Insert 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

150V 0-300V K-05GA-PZRX-C6 078-05GJ-PZRX-C6 150V 0-600V K-05GA-PZSJ-C6 078-05GJ-PZSJ-C6 150V 0-750V K-05GA-PZSM-C6 078-05GJ-PZSM-C6 150V 0-3000V K-05GA-PZUA-C6 078-05GJ-PZUA-C6 150V 0-5250V K-05GA-PZUL-C6 078-05GJ-PZUL-C6 150V 0-6000V K-05GA-PZUP-C6 078-05GJ-PZUP-C6 150V 0-9000V K-05GA-PZUY-C6 078-05GJ-PZUY-C6 150V 0-15 KV K-05GA-PZWC-C6 078-05GJA-PZWC-C6 150V 0-18 KV K-05GA-PZWD-C6 078-05GJ-PZWD-C6 150V 0-45 KV K-05GA-PZWJ-C6 078-05GJ-PZWJ-C6 250V 0-600V K-05GA-RSSJ-C6 078-05GJ-RSSJ-C6 K Insert 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

AC VOLTMETERS- RMS READING SELF CONTAINED

FREQUENCY METERS 120V SELF CONTAINED Center Frequency 50 Hz 50 Hz 50 Hz 60 Hz 60 Hz 60 Hz 60 Hz

Accuracy Hz ±0.15 ±0.15 ±0.25 ±0.25 ±0.15 ±0.15 ±0.08

K Insert 077 for 41⁄2 " Case, 079 for 83 ⁄4 " Case

51

Scale 45-55 Hz 46-54 Hz 45-65 Hz 50-70 Hz 55-65 Hz 56-64 Hz 58-62 Hz

Frequency Meter Depth 4.6"

Standard Case Catalog Number K-41LA-PNAG-AG K-41LA-PNAH-AH K-41LA-PNAJ-AJ K-41LA-PNAL-AL K-41LA-PNAN-AN K-41A-PNAO-AO K-41A-PNAT-AT

41⁄2" Square Flange Hi-Shock Case Catalog Number 078-41LJ-PNAG-AG 078-41LJ-PNAH-AH 078-41LJ-PNAJ-AJ 078-41LJ-PNAL-AL 078-41LJ-PNAN-AN 078-41LJ-PNAO-AO 078-41LJ-PNAT-AT


Crompton Switchboard Meters

NEW

DC AMMETERS - SELF CONTAINED

41⁄2" Square Flange Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 50 mV 0-15A K-05AA-EYND 078-05AJ-EYND 50 mV 0-20A K-05AA-EYNG 078-05AJ-EYNG 50 mV 0-30A K-05AA-EYNL 078-05AJ-EYNL 50 mV 0-40A K-05AA-EYNP 078-05AJ-EYNP 50 mV 0-50A K-05AA-EYNT 078-05AJ-EYNT 50 mV 0-75A K-05AA-EYPB 078-05AJ-EYPB 50 mV 0-100A K-05AA-EYPK 078-05AJ-EYPK 50 mV 0-150A K-05AA-EYPZ 078-05AJ-EYPZ 50 mV 0-200A K-05AA-EYRL 078-05AJ-EYRL 50 mV 0-300A K-05AA-EYRX 078-05AJ-EYRX 50 mV 0-400A K-05AA-EYSC 078-05AJ-EYSC 50 mV 0-500A K-05AA-EYSF 078-05AJ-EYSF 50 mV 0-750A K-05AA-EYSM 078-05AJ-EYSM 50 mV 0-1000A K-05AA-EYSS 078-05AJ-EYSS 50 mV 0-1200A K-05AA-EYSU 078-05AJ-EYSU 50 mV 0-1500A K-05AA-EYTC 078-05AJ-EYTC 50 mV 0-2000A K-05AA-EYTM 078-05AJ-EYTM 50 mV 0-3000A K-05AA-EYUA 078-05AJ-EYUA K Insert 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

007

ANALOG METERS

DC AMMETERS - SHUNT RATED

L

Rating 200 uA 300 uA 500 uA 800 uA 1 mA 2 mA 5 mA 10 mA 20 mA 30 mA 50 mA 100 mA 200 mA 300 mA 500 mA 800 mA 1A 5A 10A 15A 20A 30A K Insert

41⁄2 " Square Flange Standard Case Hi-Shock Case Scale Catalog Number Catalog Number 0-200 uA K-05AA-EAEA 078-05AJ-EAEA 0-300 uA K-05AA-EEEE 078-05AA-EEEE 0-500 uA K-05AA-EMEM 078-05AA-EMEM 0-800 uA K-05AA-EWEW 078-05AA-EWEW 0-1 mA K-05AA-FAFA 078-05AA-FAFA 0-2 mA K-05AA-FGFG 078-05AA-FGFG 0-5 mA K-05AA-FXFX 078-05AA-FXFX 0-10 mA K-05AA-GZGZ 078-05AA-GZGZ 0-20 mA K-05AA-HFHF 078-05AA-HFHF 0-30 mA K-05AA-HMHM 078-05AA-HMHM 0-50 mA K-05AA-HYHY 078-05AA-HYHY 0-100 mA K-05AA-JRJR 078-05AA-JRJR 0-200 mA K-05AA-KAKA 078-05AA-KAKA 0-300 mA K-05AA-KGKG 078-05AA-KGKG 0-500 mA K-05AA-KMKM 078-05AA-KMKM 0-800 mA K-05AA-KWKW 078-05AA-KWKW 0-1A K-05AA-LALA 078-05AA-LALA 0-5A K-05AA-LSLS 078-05AA-LSLS 0-10A K-05AA-MTMT 078-05AA-MTMT 0-15A K-05AA-NDND 078-05AA-NDND 0-20A K-05AA-NGNG 078-05AA-NGNG 0-30A K-05AA-NLNL 078-05AA-NLNL 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

DC VOLTMETERS (SENSITIVITY 1000 OHMS PER VOLTS) 41⁄2" Square Flange Standard Case Hi-Shock Case Rating Scale Catalog Number Catalog Number 15V 0-15V K-05VA-NDND 078-05VJ-NDND 30V 0-30V K-05VA-NLNL 078-05VJ-NLNL 50V 0-50V K-05VA-NTNT 078-05VJ-NTNT 75V 0-75V K-05VA-PBPB 078-05VJ-PBPB 150V 0-150V K-05VA-PZPZ 078-05VJ-PZPZ 300V 0-300V K-05VA-RXRX 078-05VJ-RXRX 400V 0-400V K-05VA-SCSC 078-05VJ-SCSC 500V 0-500V K-05VA-SFSF 078-05VJ-SFSF 600V 0-600V K-05VA-SJSJ 078-05VJ-SJSJ 750V 0-750V K-05VA-SMSM 078-05VJ-SMSM 800V 0-800V K-05VA-SNSN 078-05VJ-SNSN K Insert 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

DC VOLTMETERS - ZERO CENTER (2000 OHMS PER VOLT) 41⁄2" Square Flange Standard Case Hi-Shock Case Rating &Scale Catalog Number Catalog Number 150-0-150V K-05NA-RXRX 078-05NJ-RXRX 300-0-300V K-05NA-SJSJ 078-05NJ-SJSJ 500-0-500V K-05NA-SSSS 078-05NJ-SSSS 600-0-600V K-05NA-SUSU 078-05NJ-SUSU K Insert 007 for 41⁄2 " Plastic Case, 077 for 41⁄2 " Metal Case, 079 for 83 ⁄4 " Metal Case

TRANSDUCER INDICATORS 1/5 mA DC (suppressed zero) 4/20 mA DC (suppressed zero) 10/50 mA DC (suppressed zero) 0/10 V DC 0/50 mA DC

Custom scale — Specify markings and legend

52


Crompton Switchboard Meters AC WATTMETER AND VARMETER SPECIFICATIONS Burden per element: Voltage Circuit: Accuracy Class: Scale Arc: Position Use: Overshoot: Dielectric Withstand: Operating Temperature: Size (H x W x D):

Current Circuit: 2 VA 1 VA 1.0 250° Full Scale Deflection Vertical (Scale) 33% Maximum 2600 VRMS for 1 minute 0 to 60°C (32 to 140°F) 4.30" x 4.30" x 5.19" (077 Case)

L 077-218A

ANALOG METERS

AC WATTMETERS Phase/ Wire

Amp/ Volt

Scale

Standard Case Catalog Number

AC WATT/WATT HOUR METERS (SELF CONTAINED)

41⁄2" Square Flange Hi-Shock Case Catalog Number

1 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 1/2 5/120 To Suit + K-215A-QQ** 078-215J-QQ** 1/2 5/120 To Suit K-215A-QQ** 078-215J-QQ** 2 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3/3 5/120 To Suit + K-218A-QQ** 078-218J-QQ** 3/3 5/208 To Suit K-218A-QR** 078-218J-QR** 3/3 5/240 To Suit K-218A-QS** 078-218J-QS** 3/3 5/380 To Suit K-218A-QX** 078-218J-QX** 3/3 5/480 To Suit K-218A-QT** 078-218J-QT** 3/3 5/600 To Suit K-218A-QY** 078-218J-QY** 21⁄2 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3/4 5/69 To Suit + K-219A-QL** 078-219J-QL** 3/4 5/120 To Suit + K-219A-QQ** 078-219J-QQ** 3/4 5/277 To Suit K-219A-QY** 078-219J-QY** 3/4 5/346 To Suit K-219A-QZ** 078-219J-QZ**

Phase/ Wire

Amp/ Volt

Amp/ Volt

Scale

Standard Case Catalog Number

2 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3/3 5/120 To Suit + K-31LA-QQ** 078-31LJ-QQ** 3/3 5/208 To Suit K31LA-QR** 078-31LJ-QR** 3/3 5/240 To Suit K-31LA-QS** 078-31LJ-QS** 3/3 5/380 To Suit K-31LA-QX** 078-31LJ-QX** 3/3 5/480 To Suit K-31LA-QT** 078-31LJ-QT** 3/3 5/600 To Suit K-31LA-VY** 078-31LJ-VY**

AC SYNCHROSCOPES PIVOT AND JEWEL - 360° Volts

Hz

120V 120V 120V

50 Hz SLOW FAST 60 Hz SLOW FAST 400 Hz SLOW FAST

K Use 077 for 412⁄ " Standard Case and 079 for 834⁄ " Standard Case ** Specify Current Transformer and Voltage Transformer and Preferred Scale + 077 UL Recognized and CSA Approved , 079 UL Recognized

53

Scale

41⁄2" Square Flange Standard Case Hi-Shock Case Catalog Number Catalog Number +K-145A-PRAE-C5 078-145J-QQAB-C5

+K-146A-PRAE-C5 078-146J-QQAB-C5 +K-144A-PRAE-C4 078-144J-QQAB-C4

K Use 077 for 41⁄2" Standard Case and 079 for 83⁄4" Standard Case + - 077 UL Recognized and CSA Approved , 079 UL Recognized

K Use 077 for 412⁄ " Case and 079 for 834⁄ " Case ** Specify Current Transformer and Voltage Transformer and Preferred Scale

212⁄ element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3/4 5/120 To Suit + K-31UA-QL** 078-31UJ-QL** 3/4 5/208 To Suit K-31UA-QR** 078-31UJ-QR** 3/4 5/480 To Suit K-31UA-QT** 078-31UJ-QT** 3/4 5/600 To Suit K-31UA-VY** 078-31UJ-VY**

Scale

** - Specify pulse rate and external power supply

AC VARMETERS Phase/ Wire

41⁄2" Square Flange Standard Case Hi-Shock Case Catalog Number Catalog Number

Single element, transformer rated, 50/60 Hz, Taut Band, integral transducer 1/2 5 / 120 To Suit 077-KHBU-QQ** 077-KHBJ-QQ** 2 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3/3 5 / 120 To Suit 077-KHEU-QQ** 078-KHEU-QQ** 3/3 5 / 208 To Suit 077-KHEU-QR** 078-KHEU-QR** 212⁄ element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3/4 5 / 69 To Suit 077-KHGU-QL** 078-KHGU-QL** 3/4 5 / 120 To Suit 077-KHEU-QQ** 078-KHEU-QQ** 3/4 5 / 277 To Suit 077-KHGU-QY** 078-KHGU-QY**

K Use 077 for 412⁄ " Standard Case and 079 for 834⁄ " Standard Case ** Specify Current Transformer and Voltage Transformer and Preferred Scale + 077 UL Recognized and CSA Approved , 079 UL Recognized

41⁄2" Square Flange Hi-Shock Case Catalog Number

L077-KH

AC LED 360° SYNCHROSCOPES Volts

Hz

Scale

Standard Case Catalog Number

120V

40/65 Hz

SLOW FAST

077-14AU-PQYY-FQ

240V

40/65 Hz

SLOW FAST

077-14AU-RRYY-FQ

480V

40/65 Hz

SLOW FAST

077-14AU-SEYY-FQ


Crompton Switchboard Meters Ana-Digi Meters: Rugged taut bank construction 3 1/2 digit LED display Wide selection of inputs Standard ANSI 4 1/2" switchboard mounting

L

• • • •

077-DI Ana-Digi Meter

AC AMMETERS TRANSFORMER RATED (40/2000Hz) Digital accuracy ±0.1% ±1 counts, analog accuracy ±1%.

Rating

Scaling*

Catalog No.

5A 5A 5A 5A 5A 5A 5A

0-20A 0-50A 0-100A 0-300A 0-400A 0-500A 0-1500A

077-DIBA-LSNG-C6-** 077-DIBA-LSNT-C6-** 077-DIBA-LSPK-C6-** 077-DIBA-LSRX-C6-** 077-DIBA-LSSC-C6-** 077-DIBA-LSSF-C6-** 077-DIBA-LSTC-C6-**

Direct reading AC Ammeters also available, 1A to 10A.

PHASE SHIFTING TRANSFORMERS

AC VOLTMETERS TRANSFORMER RATED (40/2000HZ)

Phase/ Wire

Amp/ Volt

Scale

3/3 3/4 3/4

120V 120V 69V

To Suit To Suit To Suit

Standard Case Catalog Number K-956-A-PR K-957-A-PR K-956-A-NZ

41⁄2" Square Flange Hi-Shock Case Catalog Number

857-956J-PR 857-957J-PR 857-956J-NZ

Rating

Scaling*

Catalog No.

150V 150V 150V 150V 150V

0-300V 0-600V 0-750V 0-3000V 0-6000V

077-DIWA-PZRX-C6-** 077-DIWA-PZSJ-C6-** 077-DIWA-PZSM-C6-** 077-DIWA-PZUA-C6-** 077-DIWA-PZUP-C6-**

ANALOG METERS

For use with Wattmeters, when VAR measurement with external phase shifter is required

Direct reading AC Voltmeters also available, 200mV to 600V.

AC FREQUENCY METERS

K Use 855 for 412⁄ " or 834⁄ " Case

Self contained 110/130 Volt rating. Integral transducer

AC POWER FACTOR METERS (BALANCED LOAD) 4 ⁄ " Square Flange Hi-Shock Case Catalog Number 1 2

Phase/ Wire

Amp/ Volt

Scale

1/2 1/2 3 / 3 or 4 3 / 3 or 4 3 / 3 or 4 3 / 3 or 4 3 / 3 or 4

5/120 5/240 5/120 5/208 5/240 5/480 5/600

0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5

Standard Case Catalog Number + K-425A-QQAD + K-425A-QSAD + K-427A-QQAD + K-427A-QRAD + K-427A-QSAD K-427A-QTAD K-427A-QVAD

078-425J-QQAD 078-425J-QSAD 078-427J-QQAD 078-427J-QRAD 078-427J-QSAD 078-427J-QTAD 078-427J-QVAD

K Use 077 for 412⁄ " Case and 079 for 834⁄ " Case + 077 UL Recognized and CSA Approved , 079 UL Recognized

AC POWER FACTOR METERS (UNBALANCED LOAD) Phase/ Wire

3/3 3/3

Amp/ Volt

5/120 5/120

Scale

Standard Case Catalog Number

N/A N/A

AC POWER FACTOR METERS – ROTATING IRON - 360° Amp/ Volt

Scale

3 / 3 or 4 3 / 3 or 4 3/3 3/3

5/120 5/280 5/120 5/280

0-1-0 0-1-0 0-1-0 0-1-0

Standard Case Catalog Number K-136A-QQAB K-136A-QRAB K-132A-QQAB K-132A-QRAB

Accuracy

Scaling*

Catalog No.

50Hz 55Hz 60Hz 60Hz 400Hz

±0.15 ±0.25 ±0.25 ±0.15 ±1.25

45-55Hz 45-65Hz 50-70Hz 55-65Hz 360-440Hz

077-DZLA-PNAG-AG 077-DZLA-PNAJ-AJ 077-DZLA-PNAL-AL 077-DZLA-PNAN-AN 077-DZLA-PNBI-BI

Direct reading AC Ammeters also available, 1A to 10A.

DC VOLTMETERS - DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%.

Rating

Scaling*

Catalog No.

200mV 1V 5V 50V 150V 300V

0-200mV 0-1V 0-5V 0-50V 0-150V 0-300V

077-DIVA-KAKA-** 077-DIVA-LALA-** 077-DIVA-LSLS-** 077-DIVA-NTNT-** 077-DIVA-PZPZ-** 077-DIVA-RXRX-**

41⁄2" Square Flange Hi-Shock Case Catalog Number

0.5-1- 0.5 077-TFUA-QQAD 0.5-1- 0.5 077-TFUA-QQAD

Phase/ Wire

Center

41⁄2" Square Flange Hi-Shock Case Catalog Number

078-136J-QQAB 078-136J-QQAB 078-136J-QQAB 078-136J-QQAB

K Use 077 for 41⁄2" Standard Case and 079 for 83 ⁄4 " Standard Case

DC AMMETERS – DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%.

Rating

Scaling*

Catalog No.

1mA 10mA 20mA 100mA 1A

0-1mA 0-10mA 0-20mA 0-100mA 0-1A

077-DIAA-FAFA-** 077-DIAA-GZGZ-** 077-DIAA-HFHF-** 077-DIAA-JRJR-** 077-DIAA-LALA-**

** POWER SUPPLY MU BD NR PR PS Z2

– – – – – –

12 Volts DC 24 Volts DC 48 Volts DC 120 Volts DC 125 Volts DC 130 Volts DC

PO – 115 Volts AC PQ – 120 Volts AC RR – 240 Volts AC Many standard ranges not shown. *Custom scales and custom ranges on request.

54


Weschler Analog Edgewise and Panel Meters Type 252 edgewise instruments were designed specifically for the nuclear power industry. Their ruggedness and reliability make them an excellent choice for any control panel. These instruments incorporate the same taut-band suspension system that is used in the Weschler switchboard meters. They are available for direct measurement of standard electrical quantities, or in combination with transducers for measuring any other electrical or mechanical quantity that can be converted into a proportional electrical quantity.

MODIFICATIONS AVAILABLE • Internal illumination • Non-glare window • Dual scale or rating • Straight fine tubular pointer • Offset, center, or suppressed zero • Gasketed construction

The V252 & H252 Meters exceed the requirements for the 2% class specified in ANSI C39.1, and may be calibrated to 1% initial accuracy. They meet the flammability requirements of IEEE Standard 420-1973 and they have passed the seismic qualification tests under IEEE Standard 344-1987. Accuracy 1 1/2% of full scale deflection, 1% on special order. Waveform Compensation to 15% of third harmonic content. Instantaneous Overload 35x AC rating, 100x DC rating Voltage to Ground 1200V dc or peak ac, 800 volts ac rms Shielding Magnetically shielded Net Weight 1 1/2 pound Input self-contained DC 50µA to 50A 50mV to 750V AC 10mA to 20A 5V to 600V

L 252 Edgewise

L

Transducer-type frequency meters, varmeter, wattmeters and power factor meters are available.

MECHANISM ALSO AVAILABLE:

351/371 panel

Airpax panel

L

The DC instrument is of the permanent magnet moving-coil type in a core magnet construction. For ac measurement the same mechanism is used, but rectifiers and an rms network are added. This design is practically immune to the effects of magnetic fields from adjacent conductors regardless of their orientation.

L

ANALOG METERS

SPECIFICATIONS

CONSTRUCTION All components are mounted on a plastic drawer which slides into a plastic case with a clear, curved window. The entire assembly is treated to be static free. The plastic is polycarbonate (ASTM D635) for impact strength and flame retardance. Pointer edge and dial markings are on the same arc so that there is no paralax error. Instruments may be stacked horizontally or vertically. See more information online at weschler.com/analog

L 20/20 panel

55

L 221/251


Yokogawa Edgewise Switchboard Meters SPECIFICATIONS Accuracy Class Standard:

L

±1.5% of FS span AC horizontal; ±2% for AC vertical Repeatability: ±2% of FS Operating Environment Temp.: -4°F to 150°F (-20°C to 65°C) Panel Mounting: Vertical or Horizontal Case Size: 2.294" H x 6.040" W x 5.765" D Panel Cutout: 1.791" x 5.695" AC Amperes Type: Iron-Vane Frequency: 40/70 Hz AC Volts Type: Iron-Vane Frequency: 60 Hz

ANALOG METERS

180

DC AMPERES ORDERING GUIDE Rating Scale Vertical 1-5 mA ** 180 183 FYAA 8ABA 4-20 mA ** 180 183 HEAA 8ABA 10-50 mA ** 180 183 HXAA 8ABA DC Amperes Scale/ Terminal Rating Resistance Vertical 0-50 µA 4735 180 113 CYCY 0-100 µA 1480 180 113 DRDR 0-500 µA 226 180 113 EMEM 0-1 mA 40 180 113 FAFA 0-10 mA 5.0 180 113 GZGZ 0-500 mA 0.10 180 113 KMKM 0-1A 0.05 180 113 LALA 0-5A 0.010 180 113 LSLS 0-10A 0.005 180 113 MTMT 0-30A 0.001 180 113 NLNL 0-50A 0.001 180 113 NTNT DC Ammeters-50mV Shunt Rated Scale/ Terminal Rating Resistance Vertical 0-10 12.5 180 123 ECMT 0-30 12.5 180 123 ECNL 0-60 12.5 180 123 ECNW 0-100 12.5 180 123 ECPK 0-300 12.5 180 123 ECRL 0-500 12.5 180 123 ECSC 0-1KA 12.5 180 123 ECVA DC Volts-1000 Ω/Volt Rating/ Terminal Scale Resistance Vertical 0-1 1000 180 013 LALA 0-5 5000 180 013 LSLS 0-15 15000 180 013 NDND 0-50 50000 180 013 NTNT 0-150 150000 180 013 PZPZ 0-300 300000 180 013 RXRX 0-600 6000000 180 013 SJSJ 150-0-150 150000 180 014 PZPZ 300-0-300 300000 180 014 RXRX

Horizontal 180 181 FYAA 8ABA 180 181 HEAA 8ABA 180 181 HXAA 8ABA

AC AMPERES ORDERING GUIDE Horizontal 180 111 CYCY 180 111 DRDR 180 111 EMEM 180 111 FAFA 180 111 GZGZ 180 111 KMKM 180 111 LALA 180 111 LSLS 180 111 MTMT 180 111 NLNL 180 111 NTNT

Horizontal 180 121 ECMT 180 121 ECNL 180 121 ECNW 180 121 ECPK 180 121 ECRL 180 121 ECSC 180 121 ECVA

Horizontal 180 011 LALA 180 011 LSLS 180 011 NDND 180 011 NTNT 180 011 PZPZ 180 011 RXRX 180 011 SJSJ 180 012 PZPZ 180 012 RXRX

AC Amperes—50/70 Hz, Iron Vane Scale Transformer ±2% Accuracy Rating Vertical 0-1A 180 143 LALA 0-5A Self180 143 LSLS 0-10A Contained 180 143 MTMT 0-20A 180 143 NGNG 0-30A 180 143 NLNL 0-50A 180 143 NTNT AC Amperes Transformer Rated, 5A 0-10A 10/5 180 143 LSMT 0-25A 25/5 180 143 LSNJ 0-50A 50/5 180 143 LSNT 0-75A 75/5 180 143 LSPB 0-100A 100/5 180 143 LSPK 0-150A 150/5 180 143 LSPZ 0-200A 200/5 180 143 LSRL 0-400A 400/5 180 143 LSSC 0-500A 500/5 180 143 LSSF 0-1 kA 1000/5 180 143 LSVA 0-1.2 kA 1200/5 180 143 LSVB 0-1.5 kA 1500/5 180 143 LSVC AC Voltmeters—60 Hz, Iron-Vane Type 0-150V 180 033 PZPZ 0-300V Self180 033 RXRX 0-500V Contained 180 033 SFSF 0-600V 180 033 SJSJ AC Voltmeters—Transformer-Rated, 150 Volt 0-300 240/120 180 033 PZRX 0-600 480/120 180 033 PZSJ 0-750 600/120 180 033 PZSM 0-3 KV 2400/120 180 033 PZVJ 0-5.25 KV 4200/120 180 033 PZVV 0-6 KV 4800/120 180 033 PZVX

±1.5% Accuracy Horizontal 180 141 LALA 180 141 LSLS 180 141 MTMT 180 141 NGNG 180 141 NLNL 180 141 NTNT 180 141 LSMT 180 141 LSNJ 180 141 LSNT 180 141 LSPB 180 141 LSPK 180 141 LSPZ 180 141 LSRL 180 141 LSSC 180 141 LSSF 180 141 LSVA 180 141 LSVB 180 141 LSVC 180 031 PZPZ 180 031 RXRX 180 031 SFSF 180 031 SJSJ 180 031 PZRX 180 031 PZSJ 180 031 PZSM 180 031 PZVJ 180 031 PZVV 180 031 PZVX

56


Yokogawa Edgewise Panel Meters • DC & AC Meters • Four Display Sizes: 1½", 2", 2½" and 3½" • Horizontal or Vertical Orientation • Meets ANSI C-39.1 • Shielded, Dust Tight Case (Model 185) • Stackable Mounting

185 - 3 Stack Mounted

280 Series - 3 Sizes

ORDERING INFORMATION

SPECIFICATIONS

Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Orientation in box 2 . DC Ammeters - Zero Left, self-contained 1 11 2 CYCY 50 μA 1 11 2 DRDR 100 μA 1 11 2 EAEA 200 μA 1 11 2 EMEM 500 μA 1 11 2 FAFA 1 mA 1 11 2 FXFX 5 mA 1 11 2 GZGZ 10 mA 1 11 2 HFHF 20 mA 1 11 2 HJHJ 25 mA 1 11 2 HYHY 50 mA 1 11 2 JRJR 100 mA 1 11 2 KDKD 250 mA 1 11 2 KGKG 300 mA 1 11 2 KMKM 500 mA 1 11 2 LALA 1 Amp 1 11 2 LCLC 1.5 Amp 1 11 2 LELE 2 Amp 1 11 2 L J L J 3 Amp 1 11 2 LSLS 5 Amp 1 11 2 MTMT ** 10 Amp DC Ammeters - Zero Center, self-contained 1 11 2 CYCY 50-0-50 μA 1 11 2 DRDR 100-0-100 μA 1 11 2 EMEM 500-0-500 μA 1 11 2 FAFA 1-0-1 mA 1 11 2 FXFX 5-0-5 mA 1 11 2 HYHY 50-0-50 mA 1 11 2 LSLS 5-0-5 Amp DC Ammeters - Zero Left, 50mV Shunt Rated (Lead Resistance: 0.05–0.07Ω) Scale: 1 12 2 ECLA 1 Amp 1 12 2 ECLS 5 Amp 1 12 2 ECMT 10 Amp 1 12 2 ECNG 20 Amp 1 12 2 ECNT 50 Amp 1 12 2 ECRX 300 Amp 1 12 2 ECSF 500 Amp DC Ammeters - Zero Left, 100mV Shunt Rated (Lead Resistance: 0.05–0.07Ω) Scale: 1 12 2 GBLA 1 Amp 1 12 2 GBLS 5 Amp 1 12 2 GBMT 10 Amp 1 12 2 GMNG 20 Amp 1 12 2 GBNT 50 Amp 1 12 2 GBRX 300 Amp 1 12 2 GBSF 500 Amp

Model 185 286 287 288 Nominal Size 2" 1½" 2½" 3½" Face Dimensions 0.92" x 2.258" 0.498" x 1.719" 0.673" x 2.645" 0.673" x 3.525" Bezel Dimensions 1.255" x 3.025" 0.77" x 2.075" 0.99" x 3.015" 0.99" x 3.89" Depth behind panel (incl studs) 3.3" 2.47" 3.42" 3.21" Cutout (single) 0.94" x 2.286" 0.5" x 1.650" 0.687" x 2.580" 0.687" x 3.460" Scale Length 1.78" 1.25" 1.93" 2.70" Dielectric Rating RMS 1800V 1500V 1500V 2600V Overshoot (max) 40% 25% 40% 40% Accuracy 2% DC, 3% AC @ 60Hz sine Response Time 2 sec for DC & 2.5 sec for AC, except 3 sec for μA Overload 185: Voltmeter 50% momentary, 20% sustained; Ammeter 900% momentary, 20% sustained 280 Series: DC Voltmeter 20% momentary & sustained; DC Ammeter 20% sustained DC Voltmeters - Zero Left 1000 Ω/ V 1 01 2 MTMT 10 Volts 1 01 2 NDND 15 Volts 1 01 2 NLNL 30 Volts 1 01 2 NTNT 50 Volts 1 01 2 PKPK 100 Volts 1 01 2 PZPZ 150 Volts 1 01 2 RLRL * 200 Volts 1 01 2 RXRX * 300 Volts DC Voltmeters - Zero Left, Rated 0-1mADC (for use with External Resistor—not included) Scale: 1 17 2 FASF 500 Volts 1 17 2 FASJ 600 Volts 1 17 2 FASM 750 Volts DC Voltmeters - Zero Center, self-contained (1000Ω/V except 2000Ω/V in Model 185) 1 01 2 NDND 15-0-15 Volts 1 01 2 NLNL 30-0-30 Volts 1 01 2 NTNT 50-0-50 Volts 150-0-150 Volts 1 01 2 PZPZ *

ORDERING CODE GUIDE 1

2

Insert Model Number: 185 286 287 288 Insert Orientation: Zero Left Meters: 1 3 Zero Center Meters: 2 4

2" Edgewise 1½" Edgewise 2½" Edgewise 3½" Edgewise Horizontal Vertical Horizontal Vertical

AC Voltmeters - Zero Left, Rectifier Type 1000 Ω/ V 1 05 2 MTMT 10 Volts 1 05 2 NDND 15 Volts 1 05 2 NLNL 30 Volts 1 05 2 NTNT 50 Volts 1 05 2 PKPK 100 Volts 1 05 2 PZPZ 150 Volts AC Ammeters - Zero Left, Rectifier Type 1 15 2 EMEM 500 μA 1 15 2 FAFA 1 mA 1 15 2 FXFX 5 mA 1 15 2 GZGZ 10 mA 1 15 2 HFHF 20 mA

* Not available in 1½" ** Model 185 only

OPTIONS Custom Scaling Non-standard Ranges Pointer Color Color Bands External Resistor Bezel Mounting Kit (Model 185) Stacked Mounting Bezel & mounting hardware included with 280 Series. Order separately for Model 185.

56a


International Instruments Edgewise Panel Meters 3 1/2" and 6" Switchboard Meters • • • • • •

Accuracy: ±1.5% (1151/1251) Single (1146/1151) or Dual Indicators (1246/1251) Rugged Construction Flush Stacking EMI Shielded Illumination Available

ANALOG METERS

Single/Dual Models 1151/1251 and 1146/1246 These meters were initially developed to meet the demanding specifications of the Atomic Energy Commission with respect to seismic qualifications, long-life and high accuracy. The resulting product line is the most rugged and reliable available. Models 1146 and 1246 are 3 1/2 inch meters, 1151 and 1251 6-inch models, both series of instruments manufactured of modern black plastic with a design compatibility that makes them perfectly suited for use together on the same panel board. Windows are tough clear Lexan®.

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 1151-V-B-ACA 0-5/0-300 1251-V-B-ACV 0-150/0-600/B-ACA 0-5/0-400 Single A-B-C-D Dual A-B-C-D-C-D-C-D

1151

L 1251

L

A – B – C – D

A

Model 1151 6" Single 1251 6" Dual 1146 3 1/2" Single 1246 3 1/2" Dual B Orientation H Horizontal V Vertical C Zero Position Horizontal Vertical L Left T Top C Center C Center R Right B Bottom D Standard Ranges, All Models AC Volts AC Amperes AC Milliamperes 0-10, 15, 25, 50, 150, 0-5 0-10, 100, 500 300, 500 DC Volts DC Amperes DC Microamperes DC Milliamperes 0-5, 10, 15, 0-1, 2, 5, 10, 0-50, 100, 200, 0-1, 2, 3, 4, 5, 25, 30, 50, 15, 25, 50, 300, 400, 500 10, 20, 50, 100, 100, 150, 200, 100*, 200* 200, 500, 4-20, 300, 500 10-50 *=50mV shunt rated

SPECIFICATIONS Accuracy (% of FS) Repeatability Overload Response Time (sec. max.) Dielectric Strength (VRMS 60 Hz/1 min) Overshoot (max) Terminals (variations available) Scale length-inches (mm) Zero adjustment Pointer (other colors available) Weight (oz)

1146/1246 1151/1251 DC:2 AC:3 DC:1.5 AC:2.5 In Accordance with ANSI C39.1 In Accordance with ANSI C39.1 3.0 2.5 2600 40% 20% Threaded stud (10-32) Threaded stud (1/4-28) 2.7(68.6) 4.5(114.3) Yes Yes Red Delta 1146.8/1246:10 1151:25/1251:30

OPTIONS Factory Scaling—Custom Scaling (Specify) Factory Ranging Illumination—1151 & 1251 Only Adjustable Potentiometer—Voltmeters Only Zero Center Colored Bands—Price Per Color

Also available: 1 1/2", 2 1/2" & 3 1/2" Edgewise Meters

57


International Instruments Thin Panel Meters ORDERING INFORMATION

4" Edgewise Meters

• Compact Design for High Density Installations • Rugged Construction • Flush Stacking • EMI Shielded • Vertical or Horizontal Styles 1140

SPECIFICATIONS Accuracy: Repeatability: Overload: Response Time: Dielectric Strength: Overshoot: Terminals: Scale length: Zero adjustment: Pointer: Enclosure: Dimensions: Panel Cutout:

57a

±2% of full scale In Accordance with ANSI C39.1 In Accordance with ANSI C39.1 2 sec. max. 500VRMS 60 Hz/1 min 20% max Solder terminals (variations available) 3.7" Optional Red standard, other colors on reqest Steel housing with internal magnetic shield 0.515"W × 5.094"H × 4.52" behind panel 0.54" × 4.75"

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 1140-V-B-DCmA 0-5/0-300 A – B – C – D / E A

Model 1140 4" Ultra-Thin Edgewise B Orientation H Horizontal V Vertical C Zero Position Horizontal Vertical L Left T Top C Center C Center R Right B Bottom D Standard Ranges DC Volts DC Amps DC Microamps DC Milliamps 0-5, 10, 15, 0-1, 2, 5, 10, 0-50, 100, 200, 0-1, 2, 3, 4, 5, 25, 30, 50, 15, 25, 50, 300, 400, 500 10, 20, 50, 100, 100, 150, 200, 100*, 200* 200, 500, 4-20 300, 500 E Scale No entry: Scale matches meter range Custom: Specify scale and legend *=50mV shunt rated AC Voltmeters and Ammeters also available


Yokogawa ToughMeter Analog Panel Meters Designed to Operate in Harsh Environments • Metal Case and Polycarbonate Window • Gasket Sealed Bezel • Dust & Moisture Protection on Terminals & Zero Adjust • IP66 Environmental Rating • Made in the USA

NEW

SPECIFICATIONS 2 1/2" 2.70" x 1.88" 2.23" 4-40 on 2.44" BCD x3 1 /4 - 28

Case Size Size (dia x depth) Cutout (dia) Mounting studs Terminals Accuracy Repeatability Overload Overshoot Response Time Vibration Sine Vibration Random Shock Operating Temperature

3 1/2" 3.50" x 1.88" 2.55" 4-40 on 3.16" BCD x3 1 /4 - 28

±2% DC, ±3% AC ±2% 120% continuous 10% max 2 sec max 3G 10-80 Hz 3G (P&J), 5G (TB) 10-1000 Hz 50G -45 to +70°C

Vibration, temperature and environmental specifications exceed ANSI C39.1 ANALOG METERS

ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Model Code in box Order Example: 270220LSLS is taut band, 21/2" meter, 5VDC DC Ammeters - Zero Left 20 µA 50 µA 100 µA 1 mA

L 270

1

2

1

2

1

2

1

2

00CFCF 00CYCY 00DRDR 00FAFA

DC Ammeters - Zero Left, 50 mV Shunt Rated (Lead Res .05-.07Ω) 1 2 24ECNG 20 A 1 2 24ECNL 30 A 1 2 24ECNT 50 A 1 2 24ECPB 75 A 1 2 24ECPK 100 A 1 2 24ECPZ 150 A 1 2 24ECRL 200 A 1 2 24ECRS 250 A 1 2 24ECRX 300 A 1 2 24ECSC 400 A 1 2 24ECSF 500 A 1 2 24ECSJ 600 A 1 2 24ECSN 800 A 1 2 24ECVA 1.0 kA 1 2 24ECVC 1.5 kA 1 2 24ECVE 2.0 kA DC Voltmeters – Zero Left 5V 10 V 15 V 30 V 50 V 80 V 100 V 150 V 200 V 300 V 500 V 600 V

1

and Case Sizes in box

AC Ammeters - Rectifier type 1 mA 500 mA AC Voltmeters – Rectifier type 150V 300V 500V 600V Frequency 45-55 Hz, 120 VAC 45-55 Hz, 208 VAC 45-55 Hz, 240 VAC 45-65 Hz, 120 VAC 45-65 Hz, 208 VAC 45-65 Hz, 240 VAC 55-65 Hz, 120 VAC 55-65 Hz, 208 VAC 55-65 Hz, 240 VAC 380-420 Hz, 120 VAC 380-420 Hz, 208 VAC 380-420 Hz, 240 VAC

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

.

10FAFA 00KMKM

30PZPZ 30RXRX 30SFSF 30SJSJ

50AGAG 50GGGG 50DGDG 50AJAJ 50GJGJ 50DJDJ 50ANAN 50GNGN 50DNDN 50BKBK 50HKHK 50EKEK

ORDERING CODE GUIDE 1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

20LSLS 20MTMT 20NDND 20NLNL 20NTNT 20PDPD 20PKPK 20PZPZ 20RLRL 20RXRX 20SFSF 20SJSJ

1

2

Insert Model Number 270 271 Insert Case Size 2 3

Taut Band Pivot & Jewel 2 1/2 inches 3 1/2 inches

OPTIONS UL & CUL Ratings Custom Scaling Non-standard Ranges Color Bands

58


Yokogawa DC Current & Voltage Meters

ORDERING INFORMATION

ANALOG METERS

Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 . DC Ammeters—Zero Left 1 2 00LALA 1 Amp 1 2 00LCLC 1.5 Amp 1 2 00LELE 2 Amp 1 2 00LJLJ 3 Amp 1 2 00LSLS 5 Amp 1 2 00MTMT 10 Amp 1 2 00NDND 15 Amp 1 2 00NGNG* 20 Amp 1 2 00NLNL* 30 Amp 1 2 00NTNT** 50 Amp DC Ammeters—Zero Center 1 2 01LALA 1-0-1 Amp 1 2 01LELE 2-0-2 Amp 1 2 01LSLS 5-0-5 Amp 1 2 01MTMT 10-0-10 Amp 1 2 01NDND* 15-0-15 Amp 1 2 01NGNG* 20-0-20 Amp 1 2 01NLNL* 30-0-30 Amp 1 2 01NTNT** 50-0-50 Amp DC Ammeters—Zero Left, 50mV, Shunt Rated (Lead Resistance Range: .05–.07 Ohm) Scale Only 1 2 24ECNG 20 Amp 1 2 24ECNL 30 Amp 1 2 24ECNT 50 Amp 1 2 24ECPB 75 Amp 1 2 24ECPK 100 Amp 1 2 24ECPZ 150 Amp 1 2 24ECRL 200 Amp 1 2 24ECRS 250 Amp 1 2 24ECRX 300 Amp 1 2 4ECSC 400 Amp 1 2 24ECSF 500 Amp 1 2 24ECSJ 600 Amp 1 2 24ECSN 800 Amp 1 2 24ECVA 1 Kiloamp 1 2 24ECVC 1.5 Kiloamp 1 2 24ECVE 2 Kiloamp * Not available in 11⁄2" ** Not available in 11⁄2" and 21⁄2"

59

ORDERING INFORMATION DC Voltmeters—Zero Left 1 2 20LALA 1.0 Volts 1 2 20LCLC 1.5 Volts 1 2 20LJLJ 3 Volts 1 2 20LSLS 5 Volts 1 2 20MJMJ 8 Volts 1 2 20MTMT 10 Volts 1 2 20NDND 15 Volts 1 2 20NLNL 30 Volts 1 2 20NPNP 40 Volts 1 2 20NTNT 50 Volts 1 2 20PDPD 80 Volts 1 2 20PKPK 100 Volts 1 2 20PZPZ 150 Volts 1 2 20RLRL 200 Volts 1 2 20RSRS 250 Volts 1 2 20RXRX 300 Volts 1 2 20SFSF** 500 Volts 1 2 20SJSJ** 600 Volts DC Voltmeters—Zero Left, Rated 0-1mADC (for use with External Resistor—not included) Scale Only 1 2 04FASF 500 Volts 1 2 04FASJ 600 Volts 1 2 04FASM 750 Volts DC Voltmeters—Zero Center 1 2 21LSLS 5-0-5 Volts 1 2 21MTMT 10-0-10 Volts 1 2 21NLNL 30-0-30 Volts 1 2 21NTNT 50-0-50 Volts 1 2 21PDPD 80-0-80 Volts 1 2 21PZPZ 150-0-150 V 1 2 21RXRX 300-0-300 V 1 2 21SFSF** 500-0-500 V 1 2 21SJSJ** 600-0-600 V ** Not available in 11⁄2" and 21⁄2"

Horizon 251/255

L

• Accuracy: ±2% of Full Scale • Meets ANSI C-39.1 • Four Display Sizes: 11⁄ 2", 21⁄ 2", 31⁄ 2", and 41⁄ 2" • Severe Duty Meters Optional (21⁄ 2" to 41⁄ 2") to Meet UL1437

SPECIFICATIONS Model 251/255 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.86" x 2.19" x 1.34" 2.66" x 3.12" x 1.81" 3.32" x 3.89" x 1.83" 4.18" x 4.73" x 1.83" Barrel (cutout) 1.53" 2.19" 2.72" 2.72" Window (cutout) 1.05" x 2.18" 1.45" x 3.11" 1.84" x 3.88" 2.22" x 4.72" Model 250/254 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.76" x 1.76" x 1.34" 2.69" x 2.69" x 1.85" 3.50" x 3.50" x 1.85" 4.41" x 4.85" x 1.85" Barrel (cutout) 1.53" 2.17" 2.72" 2.72" Scale Length 1.40" 2.06" 2.88" 3.93" Accuracy 2% Repeatability ±0.5% Response Time 2 sec. (3 sec. on µA) Operating Temperature 0–40°C Storage Temperature –10°C–50°C Dielectric 2600V for 1 min. (0therwise per ANSI except 112⁄ " size 1500V)

L

Horizon Line and Big Look Series

Big Look 250/254

ORDERING CODE GUIDE 1

2

Insert Model Number: 250 251 254 255 Insert Case Size: 1 2 3 4

CASE AND MOVEMENT Big Look - Taut Band Horizon - Taut Band Big Look - Pivot & Jewel Horizon - Pivot & Jewel DISPLAY SIZE 112⁄ " 212⁄ " 312⁄ " 412⁄ "

OPTIONS (WHERE APPLICABLE) Custom Scaling Non-standard Ranges 1% Accuracy Adjustable Potentiometer (Voltmeters Only) Zero-Center Color Bands Bezel Insulated Cap Nuts


Yokogawa DC Current & Voltage Meters Stylist Series • Accuracy: ±2% of Full Scale • Meets ANSI C-39.1 • Four Display Sizes: 11/2", 21/2", 31/2" and 41/2" • Severe Duty Meters Optional (21/2" to 41/2") to Meet UL1437 • Surface-Mount & Window-Mount Models

ORDERING INFORMATION

2% of full scale Voltmeters: 50% momentary, 20% sustained; Ammeters: 10x momenatry, 20% sustained 2 sec. max., except 3 sec. for microammeters 2600V for 1 min. except 11/2" size 1500V ANSI C-39.1 below 500V

Stylist 260

with custom color scale

DC Ammeter s—Zer o Lef t, 50mV, Shunt Rated (Lead Resistance Range: .05–.07 Ohm) Scale Only: 1 2 20 Amp 24ECNG 1 2 30 Amp 24ECNL 1 2 50 Amp 24ECNT 1 2 75 Amp 24ECPB 1 2 100 Amp 24ECPK 1 2 150 Amp 24ECPZ 1 2 200 Amp 24ECRL 1 2 250 Amp 24ECRS 1 2 300 Amp 24ECRX 1 2 500 Amp 24ECSF 1 2 750 Amp 24ECSM 1 2 1000 Amp 24ECSS 1 2 1500 Amp 24ECTC 1 2 2000 Amp 24ECTM

ORDERING CODE GUIDE Insert Model Number: CASE and MOVEMENT 260 Surface Mount - Taut Band 261 Window Mount - Taut Band 264 Surface Mount - Pivot & Jewel 265 Window Mount - Pivot & Jewel 2 Insert Case Size: 1 11/2" 2 21/2" 3 31/2" 4 41/2" Op tions: Color Bands, Mirrored Scale, Non-standard Ranges, Custom Scaling, Severe Duty, Bezel Mounting, Insulated Cap Nuts 1

DC Voltme ter s—Zer o Lef t 1 2 24ECEC 50 millivolts 1 2 24GBGB 100 millivolts 1 2 20LALA 1.0 Volts 1 2 20LCLC 1.5 Volts 1 2 20LJLJ 3 Volts 1 2 20LSLS 5 Volts 1 2 20MJMJ 8 Volts 1 2 20MTMT 10 Volts 1 2 20NDND 15 Volts 1 2 20NLNL 30 Volts 1 2 20NPNP 40 Volts 1 2 20NTNT 50 Volts 1 2 20PDPD 80 Volts 1 2 20PKPK 100 Volts 1 2 20PZPZ 150 Volts 1 2 20RLRL 200 Volts 1 2 20RSRS 250 Volts 1 2 20RXRX 300 Volts 1 2 20SFSF 500 Volts 1 2 20SJSJ 600 Volts 1 2 20SMSM 750 Volts 1 2 20SSSS 1000 Volts DC Voltme ter s—Zer o Lef t, Rat ed 0-1mADC (for use with External Resistor—not included) Scale Only: 1 2 04FASF 500 Volts 1 2 04FASJ 600 Volts 1 2 04FASM 750 Volts DC Voltme ter s—Zer o Cent er 1 2 25ECEC 50-0-50 millivolts 100-0-100 millivolts 1 2 25GBGB 1 2 21LSLS 5-0-5 Volts 1 2 21MTMT 10-0-10 Volts 1 2 21NLNL 30-0-30 Volts 1 2 21NTNT 50-0-50 Volts 1 2 21PDPD 80-0-80 Volts 1 2 21PZPZ 150-0-150 V 1 2 21RXRX 300-0-300 V 1 2 21SFSF 500-0-500 V 1 2 21SJSJ 600-0-600 V

60

ANALOG METERS

* Not available in 11/2"

Accuracy Overload Response Time Dielectric Standard

L

Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 . DC Amme ter s—Zer o Lef t 1 2 10 microamp 00BZBZ 1 2 20 microamp 00CFCF 1 2 50 microamp 00CYCY 1 2 100 microamp 00DRDR 1 2 200 microamp 00EAEA 1 2 500 microamp 00EMEM 1 2 1 milliamp 00FAFA 1 2 2 milliamp 00FGFG 1 2 5 milliamp 00FXFX 1 2 10 milliamp 00GZGZ 1 2 20 milliamp 00HFHF 1 2 50 milliamp 00HYHY 1 2 100 milliamp 00JRJR 1 2 200 milliamp 00KAKA 1 2 500 milliamp 00KMKM 1 2 1 Amp 00LALA 1 2 1.5 Amp 00LCLC 1 2 2 Amp 00LELE 1 2 3 Amp 00LJLJ 1 2 5 Amp 00LSLS 1 2 10 Amp 00MTMT 1 2 15 Amp 00NDND* 1 2 20 Amp 00NGNG* 1 2 30 Amp 00NLNL* 1 2 50 Amp 00NTNT* DC Amme ter s—Zer o Cent er 1 2 10-0-10 microamp 01BZBZ 1 2 25-0-25 microamp 01CJCJ 1 2 50-0-50 microamp 01CYCY 100-0-100 microamp 1 2 01DRDR 500-0-500 microamp 1 2 01EMEM 1 2 1-0-1 milliamp 01FAFA 1 2 5-0-5 milliamp 01FXFX 1 2 10-0-10 milliamp 01GZGZ 1 2 25-0-25 milliamp 01HJHJ 1 2 50-0-50 milliamp 01HYHY 1 2 100-0-100 milliamp 01JRJR 1 2 200-0-200 milliamp 01KAKA 1 2 500-0-500 milliamp 01KMKM 1 2 1-0-1 Amp 01LALA 1 2 3-0-3 Amp 01LJLJ 1 2 5-0-5 Amp 01LSLS 1 2 10-0-10 Amp 01MTMT 1 2 15-0-15 Amp 01NDND* 1 2 25-0-25 Amp 01NJNJ* 1 2 50-0-50 Amp 01NTNT*

SPECIFICATIONS Window Mount Models 261/265 Case Size 21/2" 31/2" 41/2" Size (H x W x D) 2.29" x 3.01" x 2.10" 2.90" x 3.73" x 2.13" 4.60" x 5.18" x 2.13" Zero cutout 0.228" dia. 0.228" dia. 0.228" dia. Window cutout 1.27" x 2.90" 1.595" x 3.61" 2.345" x 5.02" Surface Mount Models 260/264 Case Size 11/2" 21/2" 31/2" 41/2" Size (H x W x D) 1.75" x 1.75" x 1.55" 2.27" x 2.99" x 1.80" 2.87" x 3.70" x 1.80" 3.96" x 5.10" x 1.80" Barrel cutout 1.55" 2.22" 2.82" 2.82" Scale Length 1.66" 2.29" 2.85" 4.01"


Simpson Analog Panel Meters DC Voltage/Current SPECIFICATIONS Accuracy: Operating Temp: Overload (1 Sec): Overload (Continuous):

L 2123/2124

L 1327/1329

ANALOG METERS

Wide Vue Style: Models 1227, 1327 & 1329 • UL Recognized • Wide Angle Visibility • Plastic Case with Clear Acrylic Window • Additional Ranges Upon Request

Century Style: Models 2122, 2123 & 2124 • UL Recognized • Phenolic Case and Glass Window • Additional Ranges Upon Request DC Ammeters Model 1227 21⁄2" Range Scale Catalog # 0-1 0-1 02440 0-1.5 0-1.5 02450 0-2 0-2 02460 0-3 0-3 02470 0-5 0-5 02480 0-10 0-10 02490 0-15 0-15 02500 0-25 0-25 02510 0-30 0-30 02520 0-50 0-50 02530 0-50 mV 0-100 02540* 0-50 mV 0-150 02550* 0-50 mV 0-200 02552* 0-50 mV 0-300 02554* 0-50 mV 0-500 — 15-0-15 15-0-15 — 30-0-30 30-0-30 — 50-0-50 50-0-50 —

Model 1327 31⁄2" Catalog # 02640 02650 02660 02670 02680 02690 02700 02710 02720 02730 02740* 02750* 02760* 02770* 02780* 02790 02800 02810

Model 1329 41⁄2" Catalog # 02820 02830 02840 02850 02860 02870 02880 02890 02900 02910 02920* 02930* 02940* 02950* 02960* — — —

DC Ammeters Model 2122 21⁄2" Range Scale Catalog # 0-1 0-1 17400 0-1.5 0-1.5 17401 0-2 0-2 17402 0-3 0-3 17403 0-5 0-5 17404 0-10 0-10 17405 0-15 0-15 17406 0-25 0-25 17407 0-30 0-30 17408 0-50 0-50 17409 0-50 mV 0-100 17410* 0-50 mV 0-150 — 0-50 mV 0-200 17412* 0-50 mV 0-300 — 0-50 mV 0-500 — 15-0-15 15-0-15 — 30-0-30 30-0-30 —

Model 2123 31⁄2" Catalog # 17475 17476 17477 17478 17479 17480 17481 17482 17483 17484 17485* 17486* 17487* 17488* 17489* 17490 17491

Model 2124 41⁄2" Catalog # 17565 — 17567 17568 17569 17570 17571 17572 17573 17574 17575* 17576* 17577* 17578* 17579* — —

* DC Current meters are self-contained through 50 amps. Higher ranges are supplied as 50mV meters and require an external shunt.

Both WideVue and Century styles are available in 1 1/2" Sizes. Call for info.

61

Dimensions 1227 1327 1329 2122 2123 2124

± 2% of Full Scale -20 to 65°C 10 Times Full Scale Rating 1.5 Times Full Scale Rating

Height 2.47" 3.25" 4.68" 2.34" 3.00" 4.20"

Width 2.47" 3.25" 4.68" 2.38" 3.00" 4.66"

Housing 2.17" Dia. 2.73" Dia. 2.75" Dia. 2.16" Dia. 2.69" Dia. 2.69" Dia.

DC Millivoltmeters Model 1227 21⁄2" Range Scale Catalog # 0-50 0-50 07010 50-0-50 50-0-50 —

Model 1327 31⁄2" Catalog # 07020 07021

Model 1329 41⁄2" Catalog # 07030 07031

DC Millivoltmeters Model 2122 21⁄2" Range Scale Catalog # 0-50 0-50 17472 50-0-50 50-0-50 —

Model 2123 31⁄2" Catalog # 17540 17541

Model 2124 41⁄2" Catalog # 17636 17635

DC Voltmeters Range Scale 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-100 0-100 0-150 0-150 0-200 0-200 0-250 0-250 0-300 0-300 0-500 0-500 0-750 0-750

Model 1227 21⁄2" Catalog # 09550 09560 09570 09580 09590 09600 09610 09620 09622 09623 09630 09640 09650**

Model 1327 31⁄2" Catalog # 09720 09740 09750 09760 09770 09780 09790 09800 09810 09820 09830 09840 09850

Model 1329 41⁄2" Catalog # 09870 09890 09900 09910 09920 09930 09940 09950 09960 09970 09980 09990 10000

DC Voltmeters Range Scale 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-100 0-100 0-150 0-150 0-200 0-200 0-250 0-250 0-300 0-300 0-500 0-500 0-750 0-750

Model 2122 21⁄2" Catalog # 17445 17446 17447 17448 17449 17450 17451 17452 — — 17455 17456 —

Model 2123 31⁄2" Catalog # 17525 17527 17528 17529 17530 17531 17532 17533 17534 17535 17536 17537 17538

Model 2124 41⁄2" Catalog # 17618 17620 17621 17622 17623 17624 17625 17626 17627 17628 17629 17630 17631

DC Milliammeters Range Scale 0-1 0-1 0-3 0-3 0-5 0-5 0-10 0-10 0-25 0-25 0-50 0-50

Model 1227 21⁄2" Catalog # 06175 06180 06190 06200 06220 06230

Model 1327 31⁄2" Catalog # 06310 06320 06330 06340 06370 06380

Model 1329 41⁄2" Catalog # 06470 06480 06490 06495 06530 06540

DC Milliammeters Range Scale 0-1 0-1 0-3 0-3 0-5 0-5 0-10 0-10 0-25 0-25 0-50 0-50

Model 2122 21⁄2" Catalog # 17430 17431 17432 17433 17436 17437

Model 2123 31⁄2" Catalog # 17510 17511 17512 17513 17516 17517

Model 2124 41⁄2" Catalog # 17600 17601 17602 17603 17606 17607

**External Multiplier furnished


Jewell DC Current & Voltage Meters Modutec S & W Series • Five Display Sizes: 11/2", 21/2", 31/2", 41/2" and 51/2" • Shielded Taut-Band Movement • Surface-Mount or Window-Mount Models

L S Series

SPECIFICATIONS Model W Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.77 x 2.26 x 1.83" 2.29 x 3.01 x 2.10" 2.90 x 3.73 x 2.12" 4.06 x 5.18 x 2.17" 4.60 x 5.97 x 2.17" Window (cutout) 0.935 x 2.15" 1.27 x 2.90" 1.595 x 3.61" 2.345 x 5.02" 2.59 x 5.78" Model S Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.75 x 2.24 x 1.55" 2.27 x 2.99 x 1.80" 2.87 x 3.70 x 1.80" 3.96 x 5.10 x 1.80" 4.48 x 5.85 x 1.80" Barrel (cutout) 1.55" 2.22" 2.82" 2.82" 2.82" All Models: Scale Length 1.75" 2.41" 3.0" 4.22" 5.12" Accuracy ±2% of full scale Repeatability ±0.5% of full scale Response Time 1.5 sec. (except 3 sec. for <50µA full scale)

ORDERING CODE GUIDE

ORDERING INFORMATION

W Series

ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 and Model Code in box 2 . DC Millivoltme ter s – Zer o lef t, 200Ω/V 1 2 -DMV-050 0-50 1 2 -DMV-100 0-100 DC Millivoltme ter s – Zer o cent er, 200Ω/V 1 2 -DMV-50U50 50-0-50 1 2 -DMV-1H1 100-0-100 DC Voltme ter s – Zer o lef t, 1000Ω/V, except *10kΩ/V 1 2 -DVV-001 0-1 1 2 -DVV-0015 0-1.5 1 2 -DVV-002 0-2 1 2 -DVV-003 0-3 1 2 -DVV-005 0-5 1 2 -DVV-010 0-10 1 2 -DVV-015 0-15 1 2 -DVV-020 0-20 1 2 -DVV-025 0-25 1 2 -DVV-030 0-30 1 2 -DVV-040 0-40 1 2 -DVV-050 0-50 1 2 -DVV-075 0-75 1 2 -DVV-080 0-80 1 2 -DVV-100 0-100 1 2 -DVV-150 0-150 1 2 -DVV-200 0-200 1 2 -DVV-250 0-250 1 2 -DVV-300 0-300 1 2 -DVV-500 0-500 1 2 -DVV-600 * 0-600 1 2 -DVV-750 * 0-750 1 2 -DVV-1000 * 0-1000 DC Voltme ter s – Zer o cent er, 1000Ω/V, except *10kΩ/V 1 2 -DVV-5U5 5-0-5 1 2 -DVV-10U10 10-0-10 1 2 -DVV-15U15 15-0-15 1 2 -DVV-25U25 25-0-25 1 2 -DVV-50U50 50-0-50 1 2 -DVV-1H1 100-0-100 1 2 -DVV-1.5H1.5 150-0-150 1 2 -DVV-3H3 300-0-300 1 2 -DVV-5H5 500-0-500 1 2 -DVV-6H6 * 600-0-600

1 1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

-DUA-050 -DUA-100 -DUA-200 -DUA-500 -DUA-25U25 -DUA-50U50 -DUA-1H1 -DUA-5H5 -DMA-001 -DMA-002 -DMA-003 -DMA-005 -DMA-010 -DMA-015 -DMA-020 -DMA-025 -DMA-030 -DMA-050 -DMA-100 -DMA-150 -DMA-200 -DMA-300 -DMA-500 -DMA-750 -DMA-1U1 -DMA-5U5 -DMA-10U10 -DMA-25U25 -DMA-50U50 -DMA-1H1 -DMA-2H2 -DMA-5H5 -DAA-001 -DAA-001.5 -DAA-002 -DAA-003 -DAA-005 -DAA-010 -DAA-015 ** -DAA-020 ** -DAA-025 ** -DAA-030 ** -DAA-050 ** -DAA-1U1 -DAA-3U3 -DAA-5U5 -DAA-10U10 -DAA-15U15 ** -DAA-25U25 ** -DAA-50U50 **

2

Insert Size Code: 1 2 3 4 5 Insert Model Code: S W

CASE SIZE 11/2" 21/2" 31/2" 41/2" 51/2" STYLE Surface Mount Window Mount

ANALOG METERS

L

DC Micr oamme ter s - Zer o lef t 0-50 2600 0-100 640 0-200 220 0-500 135 DC Micr oamme ter s - Zer o cent er 25-0-25 2600 50-0-50 640 100-0-100 230 500-0-500 35 DC Milliamme ter s – Zer o lef t 0-1 35.0 0-2 12.5 0-3 7.2 0-5 3.8 0-10 2.2 0-15 3.3 0-20 2.5 0-25 2.0 0-30 1.7 0-50 1.0 0-100 .50 0-150 .33 0-200 .25 0-300 .166 0-500 .10 0-750 .066 DC Milliamme ter s - Zer o cent er 1-0-1 35.0 5-0-5 3.5 10-0-10 2.2 25-0-25 2.0 50-0-50 1.0 100-0-100 .50 200-0-200 .25 500-0-500 .10 DC Amme ter s - Zer o lef t, self-cont ained 0-1 .050 0-1.5 .033 0-2 .025 0-3 .0166 0-5 .010 0-10 .0050 0-15 .0033 0-20 .0025 0-25 .0020 0-30 .0015 0-50 .0010 DC Amme ter s - Zer o cent er, self cont ained 1-0-1 .050 3-0-3 .016 5-0-5 .010 10-0-10 .005 15-0-15 .003 25-0-25 .002 50-0-50 .001

OPTIONS Custom Scaling Mirror Scale High Torque Movement Suppressed Zero

Color Bands Illumination Sealed Case Bezel Mount Kit

ORDERING INFORMATION DC Amme ter s - Zer o lef t, 50mV, shunt r at ed 1 2 -DAA-075 0-75 1 2 -DAA-100 0-100 1 2 -DAA-150 0-150 1 2 -DAA-200 0-200 1 2 -DAA-300 0-300 1 2 -DAA-500 0-500 1 2 -DAA-750 0-750 1 2 -DAA-1000 0-1000 1 2 -DAA-1200 0-1200 1 2 -DAA-1500 0-1500 1 2 -DAA-2000 0-2000 DC Amme ter s - Zer o lef t, 100mv, shunt r at ed 0-75 E 1 2 -DAA-075 0-100 E 1 2 -DAA-100 0-150 E 1 2 -DAA-150 0-200 E 1 2 -DAA-200 0-300 E 1 2 -DAA-300 0-500 E 1 2 -DAA-500 0-750 E 1 2 -DAA-750 0-1000 E 1 2 -DAA-1000 0-1200 E 1 2 -DAA-1200 0-1500 E 1 2 -DAA-1500 0-2000 E 1 2 -DAA-2000 DC Amme ter s - Zer o cent er, 50mV, shunt r at ed 1 2 -DAA-75U75 75-0-75 1 2 -DAA-1H1 100-0-100 1 2 -DAA-2H2 200-0-200 1 2 -DAA-3H3 300-0-300 1 2 -DAA-4H4 400-0-400 1 2 -DAA-5H5 500-0-500 ** not available in 11/2" size

62


Jewell DC Current & Voltage Meters Modutec PB Series • Four Display Sizes: 1½", 2½", 3½", and 4½" • Shielded Taut-Band Movement • Large, Easy to Read Scale

SPECIFICATIONS Model Case Size Size (H x W x D) Barrel (cutout) Scale Length Accuracy Repeatability Response Time

1½" 1.75 x 1.75 x 1.39" 1.53" 1.26"

PB Series 2½" 3½" 2.70 x 2.70 x 1.77" 3.50 x 3.50 x 1.77" 2.20" 2.75" 2.10" 2.90"

4½" 4.41 x 4.85 x 1.84" 2.79" 4.00"

±2% of full scale ±0.5% of full scale 1.5 sec. (except 3 sec. for <50μA full scale)

The PB series industrial panel board meters meet or exceed the requirements of ANSI C39.1. The mounting stud configuration complies with ANSI standards. Number of studs varies by size: 1½" meters - 2 studs; 2½" & 3½" meters - 3 studs; 4½" meters - 4 studs.

ORDERING CODE GUIDE

ORDERING INFORMATION

PB Series

ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 . DC Millivoltmeters – Zero left, 200Ω/V 1 PB-DMV-050 0-50 1 PB-DMV-100 0-100 DC Millivoltmeters – Zero center, 200Ω/V 1 PB-DMV-50U50 50-0-50 1 PB-DMV-1H1 100-0-100 DC Voltmeters – Zero left, 1000Ω/V, except *10kΩ/V 1 PB-DVV-001 0-1 1 PB-DVV-0015 0-1.5 1 PB-DVV-002 0-2 1 PB-DVV-003 0-3 1 PB-DVV-005 0-5 1 PB-DVV-010 0-10 1 PB-DVV-015 0-15 1 PB-DVV-020 0-20 1 PB-DVV-025 0-25 1 PB-DVV-030 0-30 1 PB-DVV-040 0-40 1 PB-DVV-050 0-50 1 PB-DVV-075 0-75 1 PB-DVV-080 0-80 1 PB-DVV-100 0-100 1 PB-DVV-150 0-150 1 PB-DVV-200 0-200 1 PB-DVV-250 0-250 1 PB-DVV-300 0-300 1 PB-DVV-500 0-500 1 PB-DVV-600 * 0-600 1 PB-DVV-750 * 0-750 1 PB-DVV-1000 * 0-1000 DC Voltmeters – Zero center, 1000 Ω/V, except *10k Ω/V 1 PB-DVV-5U5 5-0-5 1 PB-DVV-10U10 10-0-10 1 PB-DVV-15U15 15-0-15 1 PB-DVV-25U25 25-0-25 1 PB-DVV-50U50 50-0-50 1 PB-DVV-1H1 100-0-100 1 PB-DVV-1.5H1.5 150-0-150 1 PB-DVV-3H3 300-0-300 1 PB-DVV-5H5 500-0-500 1 PB-DVV-6H6 * 600-0-600

DC Microammeters - Zero left 0-50 4000 Ω 0-100 900 0-200 306 0-500 203 DC Microammeters - Zero center 25-0-25 4000 50-0-50 900 100-0-100 305 500-0-500 41 DC Milliammeters – Zero left 0-1 43.0 0-2 16.7 0-3 8.3 0-5 3.8 0-10 2.2 0-15 3.3 0-20 2.5 0-25 2.0 0-30 1.7 0-50 1.0 0-100 .50 0-150 .33 0-200 .25 0-300 .166 0-500 .10 0-750 .066 DC Milliammeters - Zero center 1-0-1 35.0 5-0-5 3.4 10-0-10 1.8 25-0-25 2.0 50-0-50 1.0 100-0-100 .50 200-0-200 .25 500-0-500 .10 DC Ammeters - Zero left, self-contained 0-1 .050 0-1.5 .033 0-2 .025 0-3 .0166 0-5 .010 0-10 .0050 0-15 .0033 0-20 .0025 0-25 .0020 0-30 .0015 0-50 .0010 DC Ammeters - Zero center, self contained 1-0-1 .050 3-0-3 .016 5-0-5 .010 10-0-10 .005 15-0-15 .003 25-0-25 .002 50-0-50 .001

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

PB-DUA-050 PB-DUA-100 PB-DUA-200 PB-DUA-500 PB-DUA-25U25 PB-DUA-50U50 PB-DUA-1H1 PB-DUA-5H5 PB-DMA-001 PB-DMA-002 PB-DMA-003 PB-DMA-005 PB-DMA-010 PB-DMA-015 PB-DMA-020 PB-DMA-025 PB-DMA-030 PB-DMA-050 PB-DMA-100 PB-DMA-150 PB-DMA-200 PB-DMA-300 PB-DMA-500 PB-DMA-750 PB-DMA-1U1 PB-DMA-5U5 PB-DMA-10U10 PB-DMA-25U25 PB-DMA-50U50 PB-DMA-1H1 PB-DMA-2H2 PB-DMA-5H5 PB-DAA-001 PB-DAA-0015 PB-DAA-002 PB-DAA-003 PB-DAA-005 PB-DAA-010 PB-DAA-015 ** PB-DAA-020 ** PB-DAA-025 ** PB-DAA-030 ** PB-DAA-050 ** PB-DAA-1U1 PB-DAA-3U3 PB-DAA-5U5 PB-DAA-10U10 PB-DAA-15U15 ** PB-DAA-25U25 ** PB-DAA-50U50 **

Insert Size Code: 1 2 3 4

CASE SIZE 1½" 2½" 3½" 4½"

OPTIONS Custom Scaling Mirror Scale High Torque Movement

Suppressed Zero Color Bands Heavy Damping

ORDERING INFORMATION DC Ammeters - Zero left, 50mV, shunt rated 1 PBS-DAA-075 0-75 1 PBS-DAA-100 0-100 1 PBS-DAA-150 0-150 1 PBS-DAA-200 0-200 1 PBS-DAA-300 0-300 1 PBS-DAA-500 0-500 1 PBS-DAA-750 0-750 1 PBS-DAA-1000 0-1000 1 PBS-DAA-1200 0-1200 1 PBS-DAA-1500 0-1500 1 PBS-DAA-2000 0-2000 DC Ammeters - Zero left, 100mv, shunt rated 0-75 E 1 PB-DAA-075 0-100 E 1 PB-DAA-100 0-150 E 1 PB-DAA-150 0-200 E 1 PB-DAA-200 0-300 E 1 PB-DAA-300 0-500 E 1 PB-DAA-500 0-750 E 1 PB-DAA-750 0-1000 E 1 PB-DAA-1000 0-1200 E 1 PB-DAA-1200 0-1500 E 1 PB-DAA-1500 0-2000 E 1 PB-DAA-2000 DC Ammeters - Zero center, 50mV, shunt rated 1 PBS-DAA-75U75 75-0-75 1 PBS-DAA-1H1 100-0-100 1 PBS-DAA-2H2 200-0-200 1 PBS-DAA-3H3 300-0-300 1 PBS-DAA-4H4 400-0-400 1 PBS-DAA-5H5 500-0-500 ** not available in 1½" size

62a


Yokogawa AC Current and Voltage Meters

ORDERING INFORMATION

ANALOG METERS

Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 . AC Microammeters and Milliammeters, Rectifier Type, Accuracy ±3% (60 Hz Sinewave @ 25°C) 1 2 10EMEM 500 µA 1 2 10EWEW 800 µA 1 2 10FAFA 1 mA 1 2 10FDFD 1.5 mA 1 2 10FGFG 2 mA 1 2 10F NF N 3 mA 1 2 10F XF X 5 mA 1 2 10GZGZ 10 mA 1 2 10HFHF 20 mA AC Milliameters-Self Contained, 25-400 Hz, Iron Vane, Pivot and Jewel 1 2 40GZGZ* 10 mA 1 2 40HJHJ* 25 mA 1 2 40HYHY* 50 mA 1 2 40JRJR* 100 mA 1 2 40K AK A* 200 mA 1 2 40K MK M* 500 mA AC Ammeters-Self Contained, 25-400 Hz, Iron Vane, Pivot and Jewel 1 2 40LALA* 1 Amp 1 2 40L JL J* 3 Amp 1 2 40LSLS* 5 Amp 1 2 40MJMJ* 8 Amp 1 2 40MTMT* 10 Amp 1 2 40NDND* 15 Amp 1 2 40NGNG* 20 Amp 1 2 40NLNL* 30 Amp 1 2 40NTNT** 50 Amp 1 2 40PDPD** 80 Amp AC Ammeters-Transformer Rated, 0-5 Amperes, 25-400 Hz, Iron Vane, Pivot and Jewel (Scale Only) 1 2 40LSMT* 10 Amp 1 2 40LSND* 15 Amp 1 2 40LSNG* 20 Amp 1 2 40LSNL* 30 Amp 1 2 40LSNP* 40 Amp 1 2 40LSNT* 50 Amp 1 2 40LSPB* 75 Amp 1 2 40LSPD* 80 Amp 1 2 40LSPK* 100 Amp 1 2 40LSPZ* 150 Amp 1 2 40LSRL* 200 Amp 1 2 40LSRX* 300 Amp 1 2 40LSSC* 400 Amp 1 2 40LSSF* 500 Amp 1 2 40LSSJ* 600 Amp 1 2 40LSSN* 800 Amp 1 2 40LSVA* 1.0 kA 1 2 40LSVB* 1.2 kA 1 2 40LSVC* 1.5 kA 1 2 40LSVE* 2.0 kA 1 2 40LSVJ* 3.0 kA

63

AC Voltmeter-Self Contained, Rectifier Type, Accuracy ±3% (60 Hz Sinewave @ 25°C) 1 2 30MTMT 10 Volts 1 2 30NDND 15 Volts 1 2 30NGNG 20 Volts 1 2 30NJNJ 25 Volts 1 2 30NLNL 30 Volts 1 2 30NTNT 50 Volts 1 2 30PDPD 80 Volts 1 2 30PKPK 100 Volts 1 2 30PZPZ 150 Volts 1 2 30RLRL** 200 Volts 1 2 30RSRS** 250 Volts 1 2 30RXRX** 300 Volts AC Voltmeter-Expanded Scale, Rectifier Type, Accuracy ±0.5% of full scale 1 2 37PNPN** 110-130 Volts 1 2 37PTPT** 105-125 Volts AC Voltmeter-Self Contained, Iron Vane, Pivot and Jewel 60 Hz Available in 250 and 251 only 1 2 44LJLJ* 3 Volts 1 2 44LSLS* 5 Volts 1 2 44MTMT* 10 Volts 1 2 44NDND* 15 Volts 1 2 44NLNL* 30 Volts 1 2 44NTNT* 50 Volts 1 2 44PKPK* 100 Volts 1 2 44PZPZ* 150 Volts 1 2 44RXRX* 300 Volts 1 2 44SFSF** 500 Volts 1 2 44SJSJ** 600 Volts AC Voltmeter-Self Contained, Iron Vane, Pivot and Jewel 400 Hz Available in 250 and 251 only 1 2 45PZPZ* 150 Volts 1 2 45RXRX* 300 Volts AC Voltmeter-Transformer Rated, 0-150 Volts Iron Vane, Pivot and Jewel, 60 Hz Available in 250 and 251 only Scale 1 2 44PZSJ* 600 Volts 1 2 44PZSM* 750 Volts 1 2 44PZVJ* 3 kV * Not Available in 11⁄2" ** Not available in 11⁄2" and 21⁄2" *** Custom scale can be matched to any transformer primary voltage

L

• Accuracy: ±2% Iron Vane Type; ±3% Rectifier Type • Four Display Sizes: 11⁄ 2", 21⁄ 2", 31⁄ 2", and 41⁄ 2" • Severe Duty Meters Optional (21⁄ 2" to 41⁄ 2") to Meet UL1437

SPECIFICATIONS Model 251/255 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.86" x 2.19" x 1.34" 2.66" x 3.12" x 1.81" 3.32" x 3.89" x 1.83" 4.18" x 4.73" x 1.83" Barrel (cutout) 1.53" 2.19" 2.72" 2.72" Window (cutout) 1.45" x 2.18" 1.45" x 3.11" 1.84" x 3.88" 2.22" x 4.72" Model 250/254 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.76" x 1.76" x 1.34" 2.69" x 2.69" x 1.85" 3.50" x 3.50" x 1.85" 4.41" x 4.85" x 1.85" Barrel (cutout) 1.53" 2.17" 2.72" 2.72" Scale Length 1.40" 2.06" 2.88" 3.93" All Models: Accuracy 2% iron vane type, 3% AC rectifier type (60 Hz sinewave) Repeatability ±0.5% Response Time 2.5 sec. Operating Temperature 0–40°C

Big Look 250/254 Series

L

Horizon Line and Big Look Series

Horizon Line 251/255

ORDERING CODE GUIDE 1

2

Insert Model Number: CASE AND MOVEMENT 250 Big Look - Taut Band 251 Horizon - Taut Band 254 Big Look - Pivot & Jewel 255 Horizon - Pivot & Jewel Insert Case Size: DISPLAY SIZE 1 112⁄ " 2 212⁄ " 3 312⁄ " 4 412⁄ "

OPTIONS (WHERE APPLICABLE) Custom Scaling Non-standard Ranges 1% Accuracy Adjustable Potentiometer (Voltmeters Only) Zero-Center Color Bands Bezel Insulated Cap Nuts


Yokogawa AC Current and Voltage Meters Stylist Series • Accuracy: ±2% Iron Vane Type; ±3% Rectifier Type • Four Display Sizes: 11/2", 21/2", 31/2" and 41/2" • Severe Duty Meters Optional (21/2" to 41/2") to Meet UL1437 ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 .

Accuracy Overload Response Time Dielectric

2% iron vane type, 3% AC rectifier type (60 Hz sinewave) Voltmeters: 50% momentary, 20% sustained; Ammeters: 10x momenatry, 20% sustained 2.5 sec. max. 2600V for 1 min. except 11/2" size 1500V

Stylist 260

with optional white on black scale

AC Amme ter s-Transf or mer Rat ed, 0-5 Amper es, 50-400 Hz, Ir on Vane*** Scale Only: 1 2 10 Amp 40LSMT* 1 2 15 Amp 40LSND* 1 2 20 Amp 40LSNG* 1 2 30 Amp 40LSNL* 1 2 40 Amp 40LSNP* 1 2 50 Amp 40LSNT* 1 2 75 Amp 40LSPB* 1 2 80 Amp 40LSPD* 1 2 100 Amp 40LSPK* 1 2 150 Amp 40LSPZ* 1 2 200 Amp 40LSRL* 1 2 300 Amp 40LSRX* 1 2 400 Amp 40LSSC* 1 2 500 Amp 40LSSF* 1 2 600 Amp 40LSSJ* 1 2 800 Amp 40LSSN* 1 2 1.0 kA 40LSVA* 1 2 1.2 kA 40LSVB* 1 2 1.5 kA 40LSVC* 1 2 2.0 kA 40LSVE* 1 2 3.0 kA 40LSVJ*

ORDERING CODE GUIDE 1

2

Insert Model Number: CASE and MOVEMENT 260 Surface Mount - Taut Band or Iron Vane 261 Window Mount - Taut Band or Iron Vane 264 Surface Mount - Pivot & Jewel 265 Window Mount - Pivot & Jewel Insert Case Size: 1 11/2" 2 21/2" 3 31/2" 4 41/2"

Op tions: Custom Scaling, Non-standard Ranges, Severe Duty, Color Bands, Bezel Mounting, Insulated Cap Nuts

AC Voltme ter-Self Cont ained, Rectif ier Type 1 2 30L JL J** 3 Volts 1 2 30LSLS** 5 Volts 1 2 30MTMT** 10 Volts 1 2 30NDND** 15 Volts 1 2 30NJNJ** 25 Volts 1 2 30NTNT** 50 Volts 1 2 30PKPK** 100 Volts 1 2 30PZPZ** 150 Volts 1 2 30RXRX** 300 Volts 1 2 30SFSF** 500 Volts 1 2 30SJSJ** 600 Volts AC Voltme ter-Expanded Scale, Rectif ier Type Accuracy ±0.5% FS 1 2 37PTPT* 105-125 Volts 1 2 37RRRR 210-250 Volts AC Voltme ter-Self Cont ained, 60 Hz Ir on Vane*** 1 2 44LSLS* 5 Volts 1 2 44MTMT* 10 Volts 1 2 44NDND* 15 Volts 1 2 44NLNL* 30 Volts 1 2 44NTNT* 50 Volts 1 2 44PKPK* 100 Volts 1 2 44PZPZ* 150 Volts 1 2 44RXRX* 300 Volts 1 2 44SFSF* 500 Volts 1 2 44SJSJ * 600 Volts AC Voltme ter-Transf or mer Rat ed, 0-150 Volts Scale Only 1 2 30PZSM** 750 Volts 1 2 30PZTC** 1500 Volts 1 2 30PZUA** 3000 Volts AC Voltme ter-Transf or mer Rat ed, 0-150 Volts Ir on Vane*** Scale Only: 1 2 44PZSJ* 600 Volts 1 2 44PZSM* 750 Volts 1 2 44PZVJ* 3 kV * Not Available in 11/2" ** 11/2" in surface mount only ***Use 260 for Surface Mount, 261 for Window Mount

64

ANALOG METERS

L

AC Milliamme ter s, Rectif ier Type , 60 Hz 1 2 10FAFA 1 mA 1 2 10FXFX 5 mA 1 2 10GZGZ 10 mA 1 2 10HJHJ 25 mA 1 2 10HYHY 50 mA 1 2 10JRJR 100 mA 1 2 10KAKA* 200 mA AC Milliame ter s-Self Cont ained, 50-400 Hz Ir on Vane*** 1 2 40GZGZ* 10 mA 1 2 40HJHJ* 25 mA 1 2 40HYHY* 50 mA 1 2 40JRJR* 100 mA 1 2 40KDKD* 250 mA 1 2 40KMKM* 500 mA AC Amme ter s-Self Cont ained, 50-400 Hz Ir on Vane*** 1 2 40LALA* 1 Amp 1 2 40LELE* 2 Amp 1 2 40L JL J* 3 Amp 1 2 40LSLS* 5 Amp 1 2 40MTMT* 10 Amp 1 2 40NDND* 15 Amp 1 2 40NGNG* 20 Amp 1 2 40NLNL* 30 Amp 1 2 40NTNT* 50 Amp AC Amme ter s-Self Cont ained, Rectif ier Type, 60 Hz 1 2 10LALA* 1 Amp 1 2 10LELE* 2 Amp 1 2 10L JL J* 3 Amp 1 2 10LSLS* 5 Amp 1 2 10MTMT* 10 Amp 1 2 10NDND* 15 Amp 1 2 10NGNG* 20 Amp 1 2 10NJNJ* 25 Amp 1 2 10NLNL* 30 Amp AC Amme ter s-Transf or mer Rat ed, 0-5 Amper es, Rectif ier Type, 60 Hz Scale Only: 1 2 10LSNT* 50 Amp 1 2 10LSPB* 75 Amp 1 2 10LSPK* 100 Amp 1 2 10LSPZ* 150 Amp 1 2 10LSRL* 200 Amp 1 2 10LSRX* 300 Amp 1 2 10LSSF* 500 Amp 1 2 10LSSJ* 600 Amp 1 2 10LSSN* 800 Amp 1 2 10LSSS* 1000 Amp 1 2 10LSTC* 1500 Amp 1 2 10LSTM* 2000 Amp

SPECIFICATIONS Window Mount Models 261/265 Case Size 21/2" 31/2" 41/2" Size (H x W x D) 2.29" x 3.01" x 2.10" 2.90" x 3.73" x 2.13" 4.60" x 5.18" x 2.13" Zero cutout 0.228" dia. 0.228" dia. 0.228" dia. Window cutout 1.27" x 2.90" 1.595" x 3.61" 2.345" x 5.02" Surface Mount Models 260/264 Case Size 11/2" 21/2" 31/2" 41/2" Size (H x W x D) 1.75" x 1.75" x 1.55" 2.27" x 2.99" x 1.80" 2.87" x 3.70" x 1.80" 3.96" x 5.10" x 1.80" Barrel cutout 1.55" 2.22" 2.82" 2.82"


Simpson Analog Panel Meters AC Voltage/Current L

SPECIFICATIONS

Century Style

L

Accuracy: Operating Temp: Overload (1 Sec): Overload (Continuous):

ANALOG METERS

Wide Vue

Wide Vue Style: Models 1247, 1257, 1347, 1357, 1349 & 1359

Century Style: Models 2142, 2143, 2152, 2153, 2144 & 2154

• UL Recognized • Wide Angle Visibility • Phenolic Case with Acrylic Window • Additional Ranges Upon Request

• UL Recognized • Phenolic Case and Glass Window • Additional Ranges Upon Request

AC Ammeters (Self-Contained) Range Scale 0-1 0-1 0-2 0-2 0-3 0-3 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-75 0-75

Model 1257 21⁄2"

Model 1357 31⁄2"

Model 1359 41⁄2"

Catalog # 02560 — 02575 02580 02590 02599 02609 02615 02619 —

Catalog # 03130 03150 03160 03170 03180 03190 03200 03205 03210 03215

Catalog # 03260 03280 03290 03300 03310 03320 03330 03335 03340 03345

AC Ammeters (Self-Contained) Range Scale 0-1 0-1 0-2 0-2 0-3 0-3 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-75 0-75

Model 2152 21⁄2"

Model 2153 31⁄2"

Model 2154 41⁄2"

Catalog # 17665 — 17667 17668 17669 17670 17671 17672 17673 —

Catalog # 17695 17697 17698 17699 17700 17701 17702 17703 17704 17710

Catalog # 17740 17742 17743 17744 17745 17746 17747 17748 17749 17755

AC Ammeters** (for use with CT) Range Scale 0-5 0-25 0-5 0-50 0-5 0-75 0-5 0-100 0-5 0-150 0-5 0-200 0-5 0-300

Model 1257 21⁄2"

Model 1357 31⁄2"

Model 1359 41⁄2"

Catalog # — — — 02622 02624 02626 02627

Catalog # 35074 35075 35076 03220 03230 03240 03250

Catalog # 35078 35079 35080 03350 03360 03370 03380

AC Ammeters** (for use with CT) Range Scale 0-5 0-25 0-5 0-50 0-5 0-75 0-5 0-100 0-5 0-150 0-5 0-200 0-5 0-300

Model 2152 21⁄2"

Model 2153 31⁄2"

Model 2154 41⁄2"

Catalog # — — — 176744 — — —

Catalog # 35082 35083 35084 17706 17707 17708 17709

Catalog # 35086 35087 35088 17751 17752 17753 17754

Dimensions 1247, 1257 1347, 1357 1349, 1359 2142, 2152 2143, 2153 2144, 2154

±2% of Full Scale (±3% Rectifier Type) -20 to 65°C 10 Times Full Scale Rating 1.5 Times Full Scale Rating

Height 2.47" 3.25" 4.68" 2.34" 3.00" 4.20"

Width 2.47" 3.25" 4.68" 2.38" 3.00" 4.66"

Housing 2.17" Dia. 2.73" Dia. 2.75" Dia. 2.16" Dia. 2.69" Dia. 2.69" Dia.

AC Voltmeters-Rectified Model 1247 21⁄2" Range Scale Catalog # 0-5 0-5 10015 0-10 0-10 10016 0-15 0-15 — 0-50 0-50 — 0-150 0-150 10017 0-300 0-300 10018

Model 1347 31⁄2" Catalog # 10020 10030 10040 10050 10060 10070

Model 1349 41⁄2" Catalog # 10090 10100 10110 10120 10130 10140

AC Voltmeters-Rectified Model 2142 21⁄2" Range Scale Catalog # 0-5 0-5 17460 0-10 0-10 — 0-15 0-15 — 0-50 0-50 — 0-150 0-150 17462

Model 2143 31⁄2"Catalog # 17542 17543 17544 17545 17546

Model 2144 41⁄2" Catalog # 17640 17641 17642 17643 17644

Voltmeters-Iron Vane Range Scale 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-50 0-50 0-100 0-100 0-150 0-150 0-250 0-250 0-300 0-300 0-500 0-500

Model 1257 21⁄2" Catalog # — 09670 09675 09680 09690 09695 09700 09705 09710 09715*

Model 1357 31⁄2" Catalog # 10160 10170 10180 10190 10200 10210 10220 10230 10240 10250*

Model 1359 41⁄2" Catalog # 10260 10270 10280 10290 10300 10310 10320 10330 10340 10350*

Voltmeters-Iron Vane Range Scale 0-10 0-10 0-15 0-15 0-25 0-25 0-50 0-50 0-100 0-100 0-150 0-150 0-250 0-250 0-300 0-300 0-500 0-500

Model 2152 21⁄2" Catalog # 17685 17686 17687 17688 — 17690 17691 17692 —

Model 2153 31⁄2" Catalog # 17726 17727 17728 17729 17730 17731 17732 17733 17734*

Model 2154 41⁄2" Catalog # 17771 17772 17773 17774 17775 17776 17777 17778 17779*

AC Milliammeters Range Scale 0-10 0-10 0-50 0-50 0-100 0-100 0-250 0-250 0-500 0-500

Model 1257 21⁄2" Catalog # 06294 06295 06296 06297 06300

Model 1357 31⁄2" Catalog # 06625 06630 06640 06650 06660

Model 1359 41⁄2" Catalog # 06665 06670 06680 06690 06699

AC Millammeters Range Scale 0-10 0-10 0-50 0-50 0-100 0-100 0-250 0-250 0-500 0-500

Model 2152 21⁄2" Catalog # 17680 17681 17682 17683 17684

Model 2153 31⁄2" Catalog # — 17716 17717 17718 17719

Model 2154 41⁄2" Catalog # 17760 17761 17762 17763 17764

* External multipliers are furnished on AC meters having a range of 500 volts or higher. ** These meters require an external current transformer.

65


Jewell AC Current and Voltage Meters SPECIFICATIONS

Modutec S & W Series

L

• Five Display Sizes: 11/2", 21/2", 31/2", 41/2" and 51/2" • Shielded Taut-Band Movement • Surface-Mount or Window-Mount Models

S Series

Model W Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.77 x 2.26 x 1.83" 2.29 x 3.01 x 2.10" 2.90 x 3.73 x 2.12" 4.06 x 5.18 x 2.17" 4.60 x 5.97 x 2.17" Window (cutout) 0.935 x 2.15" 1.27 x 2.90" 1.595 x 3.61" 2.345 x 5.02" 2.59 x 5.78" Model S Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.75 x 2.24 x 1.55" 2.27 x 2.99 x 1.80" 2.87 x 3.70 x 1.80" 3.96 x 5.10 x 1.80" 4.48 x 5.85 x 1.80" Barrel (cutout) 1.55" 2.22" 2.82" 2.82" 2.82" All Models: Scale Length (Rect/Iron) 1.75" 2.41"/2.15" 3.0"/2.7" 4.22"/3.8" 5.12"/--Accuracy ±2% iron vane type, ±3% AC rectifier type (60 Hz sinewave) Repeatability ±2% iron vane, ±0.5% rectifier type Response Time 1.5 sec. (except 3 sec. for <50µA full scale)

ORDERING CODE GUIDE

W Series

Custom Scaling Mirror Scale High Torque Movement Color Bands

Illumination Custom Artwork Sealed Case Bezel Mount Kit

Also Available: VU Meters & Elapsed Time Meters These meters are available in both moving coil (rectifier type) and iron vane versions. The iron vane construction is relatively insensitive to input distortion. The rectifier type is less affected by frequency variations.

ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 and Model Code in box 2 . AC Voltme ter s – Self-cont ained, r ectif ier type, 900Ω/V 1 2 0-3 -AVV-003 1 2 0-5 -AVV-005 1 2 0-10 -AVV-010 1 2 0-15 -AVV-015 1 2 0-25 -AVV-025 1 2 0-50 -AVV-050 1 2 0-100 -AVV-100 1 2 0-150 -AVV-150 1 2 0-300 -AVV-300 1 2 0-500 -AVV-500 1 2 0-600 -AVV-600 AC Voltme ter s – Transf or mer r at ed, 0-150V, r ectif ier type 1 2 0-750 -AVV-750 1 2 0-1500 -AVV-1500 1 2 0-3000 -AVV-3000 AC Voltme ter s – Ir on vane: self-cont ained, 60Hz nominal 1 2 0-3 -AVC-003 ** 1 2 0-5 -AVC-005 ** 1 2 0-10 -AVC-010 ** 1 2 0-15 -AVC-015 ** 1 2 0-30 -AVC-030 ** 1 2 0-50 -AVC-050 ** 1 2 0-100 -AVC-100 ** 1 2 0-150 -AVC-150 ** 1 2 0-300 -AVC-300 ** 1 2 0-500 -AVC-500 ** 1 2 0-600 -AVC-600 ** AC Voltme ter s – Ir on vane: tr ansf or mer r at ed, 0-150V, 60Hz 1 2 0-600 -AVCX-600 ** 1 2 0-750 -AVCX-750 ** 1 2 0-1500 -AVCX-1500 ** 1 2 0-3000 -AVCX-3000 **

ORDERING INFORMATION AC Milliamme ter s – Self-cont ained, r ectif ier type 1 2 0-1 1100W -AMA-001 1 2 0-5 260 -AMA-005 1 2 0-10 140 -AMA-010 1 2 0-25 90 -AMA-025 1 2 0-50 45 -AMA-050 1 2 0-100 6.0 -AMA-100 1 2 0-200 1.5 -AMA-200 * 1 2 0-500 .4 -AMA-500 * AC Milliamme ter s – Ir on vane: Self-cont ained, 60Hz nominal input (50-400Hz r ange) 1 2 0-10 2600 -AMC-010 ** 1 2 0-25 430 -AMC-025 ** 1 2 0-50 105 -AMC-050 ** 1 2 0-100 27 -AMC-100 ** 1 2 0-250 4.3 -AMC-250 ** 1 2 0-500 1.1 -AMC-500 ** AC Amme ter s – Self-cont ained, r ectif ier type 1 2 0-1 .07 -AAA-001 * 1 2 0-1.5 .05 -AAA-0015 * 1 2 0-2 .04 -AAA-002 * 1 2 0-3 .025 -AAA-003 * 1 2 0-5 .015 -AAA-005 * 1 2 0-10 .0075 -AAA-010 * 1 2 0-15 .005 -AAA-015 * 1 2 0-20 .004 -AAA-020 * 1 2 0-25 .0037 -AAA-025 * 1 2 0-30 .0025 -AAA-030 * 1 2 0-50 .0015 -AAA-050 * AC Amme ter s – Ir on vane: Self-cont ained, 60Hz nominal input (50-400Hz r ange) 1 2 0-1 .26 -AAC-001 ** 1 2 0-1.5 .12 -AAC-0015 ** 1 2 0-2 .07 -AAC-002 ** 1 2 0-3 .048 -AAC-003 ** 1 2 0-5 .022 -AAC-005 ** 1 2 0-10 .005 -AAC-010 ** 1 2 0-15 .003 -AAC-015 ** 1 2 0-20 .002 -AAC-020 ** 1 2 0-25 .002 -AAC-025 ** 1 2 0-30 .0015 -AAC-030 ** 1 2 0-50 .001 -AAC-050 **

Insert Size Code: CASE SIZE 1 11/2" 2 21/2" 3 31/2" 4 41/2" 5 51/2" 2 Insert Model Code: STYLE S Surface Mount W Window Mount 1

AC Amme ter s – Transf or mer r at ed, 0-5A , r ectif ier type 1 2 0-60 -AAAX-060 * 1 2 0-75 -AAAX-075 * 1 2 0-100 -AAAX-100 * 1 2 0-150 -AAAX-150 * 1 2 0-200 -AAAX-200 * 1 2 0-300 -AAAX-300 * 1 2 0-400 -AAAX-400 * 1 2 0-500 -AAAX-500 * 1 2 0-600 -AAAX-600 * 1 2 0-800 -AAAX-800 * 1 2 0-1000 -AAAX-1000 * 1 2 0-1500 -AAAX-1500 * 1 2 0-2000 -AAAX-2000 * AC Amme ter s – Ir on vane: Transf or mer r at ed, 0-5A , 60Hz nominal input (50-400Hz r ange) 1 2 0-60 -AACX-060 ** 1 2 0-75 -AACX-075 ** 1 2 0-100 -AACX-100 ** 1 2 0-150 -AACX-150 ** 1 2 0-200 -AACX-200 ** 1 2 0-300 -AACX-300 ** 1 2 0-500 -AACX-500 ** 1 2 0-600 -AACX-600 ** 1 2 0-800 -AACX-800 ** 1 2 0-1000 -AACX-1000 ** 1 2 0-1500 -AACX-1500 ** 1 2 0-2000 -AACX-2000 ** Frequency Me ter s – Point er Type Electr onic 1 2 45-65 Hz 120V -FRQ-55/120-20 ** 1 2 45-55 120 -FRQ-50/120-10 ** 1 2 55-65 120 -FRQ-60/120-10 ** 1 2 380-420 120 -FRQ-400/120-40 ** 1 2 45-55 230 -FRQ-50/230-10 ** 1 2 55-65 230 -FRQ-60/230-10 **

*not available in 11/2" size **not available in 11/2" or 51/2" sizes

66

ANALOG METERS

L

OPTIONS (WHERE APPLICABLE)


Jewell AC Current and Voltage Meters Modutec PB Series • Four Display Sizes: 1½", 2½", 3½", and 4½" • Shielded Taut-Band Movement • Large, Easy to Read Scale

SPECIFICATIONS Model Case Size Size (H x W x D) Barrel (cutout) Scale Length Accuracy Repeatability Response Time

1½" 1.75 x 1.75 x 1.39" 1.53" 1.26"

PB Series 2½" 3½" 2.70 x 2.70 x 1.77" 3.50 x 3.50 x 1.77" 2.20" 2.75" 2.10" 2.90"

4½" 4.41 x 4.85 x 1.84" 2.79" 4.00"

±2% iron vane type, ±3% AC rectifier type (60 Hz sinewave) ±2% iron vane, ±0.5% rectifier type 1.5 sec. (except 3 sec. for <50μA full scale)

The PB series industrial panel board meters meet or exceed the requirements of ANSI C39.1. The mounting stud configuration complies with ANSI standards. Number of studs varies by size: 1½" meters - 2 studs; 2½" & 3½" meters - 3 studs; 4½" meters - 4 studs.

ORDERING CODE GUIDE

OPTIONS (WHERE APPLICABLE)

PB Series

Custom Scaling Mirror Scale High Torque Movement

Color Bands Custom Artwork Heavy Damping

Also Available: VU Meters & Elapsed Time Meters These meters are available in both moving coil (rectifier type) and iron vane versions. The iron vane construction is relatively insensitive to input distortion. The rectifier type is less affected by frequency variations.

ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 . AC Voltmeters – Self-contained, rectifier type, 900Ω/V 1 PB-AVV-003 0-3 1 PB-AVV-005 0-5 1 PB-AVV-010 0-10 1 PB-AVV-015 0-15 1 PB-AVV-025 0-25 1 PB-AVV-050 0-50 1 PB-AVV-100 0-100 1 PB-AVV-150 0-150 1 PB-AVV-300 0-300 1 PB-AVV-500 0-500 1 PB-AVV-600 0-600 AC Voltmeters – Transformer rated, 0-150V, rectifier type 1 PB-AVVX-750 0-750 1 PB-AVVX-1500 0-1500 1 PB-AVVX-3000 0-3000 AC Voltmeters – Iron vane: self-contained, 60Hz nominal 1 PB-AVC-003 * 0-3 1 PB-AVC-005 * 0-5 1 PB-AVC-010 * 0-10 1 PB-AVC-015 * 0-15 1 PB-AVC-030 * 0-30 1 PB-AVC-050 * 0-50 1 PB-AVC-100 * 0-100 1 PB-AVC-150 * 0-150 1 PB-AVC-300 * 0-300 1 PB-AVC-500 * 0-500 1 PB-AVC-600 * 0-600 AC Voltmeters – Iron vane: transformer rated, 0-150V, 60Hz 1 PB-AVCX-600 * 0-600 1 PB-AVCX-750 * 0-750 1 PB-AVCX-1500 * 0-1500 1 PB-AVCX-3000 * 0-3000

1

Insert Size Code: 1 2 3 4

CASE SIZE 1½" 2½" 3½" 4½"

ORDERING INFORMATION AC Milliammeters – Self-contained, rectifier type 1 PB-AMA-001 0-1 1100 Ω 1 PB-AMA-005 0-5 260 1 PB-AMA-010 0-10 140 1 PB-AMA-025 0-25 90.0 1 PB-AMA-050 0-50 45.0 1 PB-AMA-100 0-100 6.0 1 PB-AMA-200 0-200 1.5 1 PB-AMA-500 0-500 .4 AC Milliammeters – Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) 1 PB-AMC-010 * 0-10 2600 1 PB-AMC-025 * 0-25 430 1 PB-AMC-050 * 0-50 105 1 PB-AMC-100 * 0-100 27 1 PB-AMA-250 * 0-250 4.3 1 PB-AMC-500 * 0-500 1.1 AC Ammeters – Self-contained, rectifier type 1 PB-AAA-001 * 0-1 .07 1 PB-AAA-0015 * 0-1.5 .05 1 PB-AAA-002 * 0-2 .04 1 PB-AAA-003 * 0-3 .025 1 PB-AAA-005 * 0-5 .015 1 PB-AAA-010 * 0-10 .0075 1 PB-AAA-015 * 0-15 .005 1 PB-AAA-020 * 0-20 .004 1 PB-AAA-025 * 0-25 .0037 1 PB-AAA-030 * 0-30 .0025 1 PB-AAA-050 * 0-50 .0015 AC Ammeters – Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) 1 PB-AAC-001 * 0-1 .20 1 PB-AAC-0015 * 0-1.5 .012 1 PB-AAC-002 * 0-2 .07 1 PB-AAC-003 * 0-3 .048 1 PB-AAC-005 * 0-5 .022 1 PB-AAC-010 * 0-10 .005 1 PB-AAC-015 * 0-15 .003 1 PB-AAC-020 * 0-20 .002 1 PB-AAC-025 * 0-25 .002 1 PB-AAC-030 * 0-30 .0015 1 PB-AAC-050 * 0-50 .001

ORDERING INFORMATION AC Ammeters – Transformer rated, 0-5A, rectifier type 1 PB-AAAX-060 0-60 1 PB-AAAX-075 0-75 1 PB-AAAX-100 0-100 1 PB-AAAX-150 0-150 1 PB-AAAX-200 0-200 1 PB-AAAX-300 0-300 1 PB-AAAX-400 0-400 1 PB-AAAX-500 0-500 1 PB-AAAX-600 0-600 1 PB-AAAX-800 0-800 1 PB-AAAX-1000 0-1000 1 PB-AAAX-1500 0-1500 1 PB-AAAX-2000 0-2000 AC Ammeters – Iron vane: Transformer rated, 0-5A, 60Hz nominal input (50-400Hz range) 1 PB-AACX-060 * 0-60 1 PB-AACX-075 * 0-75 1 PB-AACX-100 * 0-100 1 PB-AACX-150 * 0-150 1 PB-AACX-200 * 0-200 1 PB-AACX-300 * 0-300 1 PB-AACX-500 * 0-500 1 PB-AACX-600 * 0-600 1 PB-AACX-800 * 0-800 1 PB-AACX-1000 * 0-1000 1 PB-AACX-1500 * 0-1500 1 PB-AACX-2000 * 0-2000 Frequency Meters – Pointer Type Electronic 1 PB-55/120-20 * 45-65 Hz 120V 1 PB-50/120-10 * 45-55 120 1 PB-60/120-10 * 55-65 120 1 PB-400/120-10 * 380-420 120 1 PB-50/230-10 * 45-55 230 1 PB-60/230-10 * 55-65 230

*not available in 1½" size

66a


Yokogawa AC Motor Load and Frequency Meters Horizon Line and Big Look Series • Accuracy: ±2% of Full Scale, ±3% of span for Frequency • Meets ANSI C-39.1 • Four Display Sizes: 11⁄ 2", 21⁄ 2", 31⁄ 2", and 41⁄ 2" • Severe Duty Meters Optional (21⁄ 2" to 41⁄ 2") to Meet UL1437 • Surface-Mount or Window-Mount Models

SPECIFICATIONS

L

255

L

ANALOG METERS

250

Model Case Size Size (H x W x D) Barrel (cutout) Window (cutout) Model Case Size Size (H x W x D) Barrel (cutout) Scale Length Accuracy Repeatability Response Time Operating Temperature Storage Temperature Dielectric

251/255 21⁄2" 31⁄2" 41⁄2" 2.66" x 3.12" x 1.81" 3.32" x 3.89" x 1.83" 4.18" x 4.73" x 1.83" 2.19" 2.72" 2.72" 1.45" x 3.11" 1.84" x 3.88" 2.22" x 4.72" 250/254 21⁄2" 31⁄2" 41⁄2" 2.69" x 2.69" x 1.85" 3.50" x 3.50" x 1.85" 4.41" x 4.85" x 1.85" 2.17" 2.72" 2.72" 2.06" 2.88" 3.93" ±2% of Full Scale, ±3% of span for Frequency ±0.5% 2.5 sec. 0–40°C –10°C–50°C 2600V for 1 min. (0therwise per ANSI) except 112⁄ " size 1500V)

ORDERING INFORMATION AC Motors Load Indicators Rating Amps Scale Marking 5 0-150% motor load current, Red band: 100-150 5 0-150% motor load current Green band: 0-100, yellow: 100-125, red: 125-150 5 0-150% motor load current, Red band: 100-150 5 0-150% motor load current Green band: 0-100, yellow: 100-125, red: 125-150 AC Frequency Meters, Self Contained, Accuracy ±3% of Span Voltage Input Center Frequency Scale (Hz) 120 VAC 50 45-55 120 VAC 55 45-65 120 VAC 60 55-65 120 VAC 400 380-420 208 VAC 50 45-55 208 VAC 55 45-65 208 VAC 60 55-65 208 VAC 400 380-420 240 VAC 50 45-55 240 VAC 55 45-65 240 VAC 60 55-65 240 VAC 400 380-420 K Insert: 254 - for Big Look

255 - for Horizon Line

67

Type 250 250

21⁄2" 250240LSPZ7AAA 250240LSPZ7AAB

31⁄2" 250340LSPZ7AAA 250340LSPZ7AAB

41⁄2" 250440LSPZ7AAA 250440LSPZ7AAB

251 251

251240LSPZ7AAJ 251240LSPZ7AAK

251340LSPZ7AAJ 251340LSPZ7AAK

251440LSPZ7AAJ 251440LSPZ7AAK

K K K K K K K K K K K K

250AGAG 250AJAJ 250ANAN 250BKBK 250GGGG 250GJGJ 250GNGN 250HKHK 250DGDG 250DJDJ 250DNDN 250EKEK

K K K K K K K K K K K K

350AGAG 350AJAJ 350ANAN 350BKBK 350GGGG 350GJGJ 350GNGN 350HKHK 350DGDG 350DJDJ 350DNDN 350EKEK

K K K K K K K K K K K K

450AGAG 450AJAJ 450ANAN 450BKBK 450GGGG 450GJGJ 450GNGN 450HKHK 450DGDG 450DJDJ 450DNDN 450EKEK


Simpson Frequency Meters • Four Different Models • 21⁄2", 31⁄2" and 41⁄2" sizes Simpsons frequency meters are ideal for monitoring line frequency. They are used wherever fast, precise monitoring of complex circuits is essential. Segmental scale meters present a selected frequency range across the entire dial face in linear fashion, where other meters are squeezed into a quarter of an inch of space.

Wide-Vue

L

Century

L

SPECIFICATIONS 3% of span Pivot and Jewel Small Core Magnet

Rectangular

ANALOG METERS

Accuracy: Suspension: Movement:

L

L

Round

ORDERING INFORMATION Model: 1287, 21⁄2" WIDEVUE Cat # Frequency Voltage 35100 45-55 HZ 120V 35101 45-55 HZ 240V 35102 55-65 HZ 120V 35103 55-65 HZ 240V 35104 380-420 HZ 120V 35105 380-420 HZ 240V Model: 2182, 21⁄2" CENTURY Cat # Frequency Voltage 35118 45-55 HZ 120V 35119 45-55 HZ 240V 35120 55-65 HZ 120V 35121 55-65 HZ 240V 35122 380-420 HZ 120V 35123 380-420 HZ 240V Model: 187, 21⁄2" RECTANGULAR Cat # Frequency Voltage 35136 45-55 HZ 120V 35137 45-55 HZ 240V 35138 55-65 HZ 120V 35139 55-65 HZ 240V 35140 380-420 HZ 120V 35141 380-420 HZ 240V Model: 185, 21⁄2" ROUND Cat # Frequency Voltage 35154 45-55 HZ 120V 35155 45-55 HZ 240V 35156 55-65 HZ 120V 35157 55-65 HZ 240V 35158 380-420 HZ 120V 35159 380-420 HZ 240V

Model: 1387, 31⁄2" WIDEVUE Cat # Frequency 35106 45-55 HZ 35107 45-55 HZ 35108 55-65 HZ 35109 55-65 HZ 35110 380-420 HZ 35111 380-420 HZ Model: 2183, 31⁄2" CENTURY Cat # Frequency 35124 45-55 HZ 35125 45-55 HZ 35126 55-65 HZ 35127 55-65 HZ 35128 380-420 HZ 35129 380-420 HZ Model: 87, 31⁄2" RECTANGULAR Cat # Frequency 35142 45-55 HZ 35143 45-55 HZ 35144 55-65 HZ 35145 55-65 HZ 35146 380-420 HZ 35147 380-420 HZ Model: 85, 31⁄2" ROUND Cat # Frequency 35160 45-55 HZ 35161 45-55 HZ 35162 55-65 HZ 35163 55-65 HZ 35164 380-420 HZ 35165 380-420 HZ

Voltage 120V 240V 120V 240V 120V 240V Voltage 120V 240V 120V 240V 120V 240V Voltage 120V 240V 120V 240V 120V 240V

Model: 1389, 41⁄2" WIDEVUE Cat # Frequency 35112 45-55 HZ 35113 45-55 HZ 35114 55-65 HZ 35115 55-65 HZ 35116 380-420 HZ 35117 380-420 HZ Model: 2184, 41⁄2" CENTURY Cat # Frequency 35130 45-55 HZ 35131 45-55 HZ 35132 55-65 HZ 35133 55-65 HZ 35134 380-420 HZ 35135 380-420 HZ Model: 89, 41⁄2" RECTANGULAR Cat # Frequency 35148 45-55 HZ 35149 45-55 HZ 35150 55-65 HZ 35151 55-65 HZ 35152 380-420 HZ 35153 380-420 HZ

Voltage 120V 240V 120V 240V 120V 240V Voltage 120V 240V 120V 240V 120V 240V Voltage 120V 240V 120V 240V 120V 240V

Voltage 120V 240V 120V 240V 120V 240V

68


Crompton 31⁄2" Fiesta Panel Meters

L

016 Series

AC Ammeter

Introduction A range of shortscale and longscale panel meters. Their rugged design will suit demanding environmental applications.

• Dust and Water Jet Protected to IP55 (IEC529) • Withstands High Levels of Shock, Vibration, Dirt and Humidity • The Contoured Window Gives an Exceptionally Wide Viewing Angle • Complies with ANSI-C39 (IEC 51) • UL Approval for Short Scale Ammeters, Voltmeters, Frequency Meters and Elapsed Time Meters on Selected Ranges. File Number E87815 • Instruments Comply with BSEN61010-1 Meets IEC414 (BS5458) Dielectric Test (2600V for 1 min) • IP55 (NEMA 4)

L

ANALOG METERS

Features

AC Voltmeter

Options On request the following are available:

Supplementary Pointer Non-Reflecting Window Heavily Damped Movement Panel Gasket Clamp Band Fixing Colored Internal Gasket

ELAPSED TIME METER AND FREQUENCY METER Voltage: Frequency: Burden:

100/125V, 200/250V or 480 VAC 50 Hz or 60 Hz 4 VA Maximum

IRON VANE A.C. AMMETER & VOLTMETER Accuracy: Ratings Ammeters: Voltmeters: Overload Ammeters: Voltmeters: Burden Ammeters: Voltmeters:

69

Shortscale: 2.5%; Longscale: 1.5% Shortscale: 1 to 80A Longscale: 1 to 20A 10V to 600V x1.2 for 2 hours 10 x for 5 seconds x1.2 for 2 hours 2 x for 5 seconds Shortscale: 0.5 VA Long scale: 1.5 VA 4.5 VA Maximum

L

• • • • • •

DC Voltmeter

MOVING COIL D.C. AMMETER & VOLTMETER Accuracy Class: Rating Ammeters: Voltmeters: Overload Ammeters: Voltmeters: Impedance:

Shortscale: 1.5 Longscale: 1.5 200 mA to 30A (100 mA Shortscale) 50 mV to 600V x1.2 for 2 hours x10 for 5 seconds x1.2 for 2 hours x2 for 5 seconds Voltmeters: 1000 ohms per volt nominal

TEMPERATURE RANGE (ALL TYPES) Operating: Storage:

-20°C to 65°C (-4°F to 149°F) -30°C to 70°C (-22°F to 158°F)

Shortscale: Longscale:

90° scale arc 270° scale arc


Crompton 31⁄2" Fiesta Panel Meters 016 Series A.C. Ammeters - True RMS Reading Rating Self Contained 40/70Hz 5A 10A 15A 20A 30A 5A

Scaling

Shortscale Catalog No.

Longscale Catalog No.

0-5A 0-10A 0-15A 0-20A 0-30A Transformer Rated

• 016-02AA-LSLS 016-02AA-MTMT 016-02AA-NDND 016-02AA-NGNG 016-02AA-NLNL • 016-02AA-LS**

016-03AA-LSLS 016-03AA-MTMT 016-03AA-NDND 016-03AA-NGNG 016-03AA-NLNL 016-03AA-LS**

• • • •

016-02VA-PZPZ 016-02VA-RXRX 016-02VA-SJSJ 016-02VA-PZ**

016-03VA-PZPZ 016-03VA-RXRX 016-03VA-SJSJ 016-03VA-PZ**

D.C. Ammeters 0-50 mV 0-1 mA 0-5 mA 0-10 mA 0-20 mA

016-01AA-EC** • 016-01AA-FA** 016-01AA-FX** 016-01AA-HA** • 016-01AA-HF**

016-05AA-EC** 016-05AA-FA** 016-05AA-FX** 016-05AA-HA** 016-05AA-HF**

Milliammeters - Suppressed Zero no zero set unless specified 4/20 mA To Suit Requirements • 016-01RA-HG**

016-05RA-HG**

D.C. Voltmeters (Sensitivity 1000Ω/Volt) 0-15V 0-15V 0-30V 0-30V 0-50V 0-50V 0-150V 0-150V 0-300V 0-300V 0-600V 0-600V

016-01VA-NDND 016-01VA-NLNL • 016-01VA-NTNT • 016-01VA-PZPZ • 016-01VA-RXRX 016-01VA-SJSJ

016-05VA-NDND 016-05VA-NLNL 016-05VA-NTNT 016-05VA-PZPZ 016-05VA-RXRX 016-05VA-SJSJ

Frequency Meters, 120V* (Self Contained) Center Freq Hz Accuracy 50 Hz -0.15 50 Hz -0.25 60 Hz -0.15 60 Hz -0.25 400 Hz -1.25

Standard Case Scale 45-55 Hz 45-65 Hz 55-65 Hz 56-64 Hz 360-440 Hz

Catalog No. • 016-41SA-PNAG-AG • 016-41SA-PNAJ-AJ • 016-41SA-PNAN-AN • 016-41SA-PNAO-AO 016-41SA-PNBI-BI

Standard Case Scale — — — — — —

Catalog No. • 016-155A-PNZH-C5 • 016-155A-RNZH-C5 016-155A-SEZH-C5 • 016-156A-PNZH-C6 • 016-156A-RNZH-C6 016-156A-SEZH-C6

To Suit Requirements To Suit Requirements To Suit Requirements To Suit Requirements To Suit Requirements

Longscale AC Ammeter

L ANALOG METERS

A.C. Voltmeters - True RMS Reading 150V 0-150V 300V 0-300V 600V 0-600V 150V Transformer Rated

Frequency Meter

L

*Alternate voltage rating 200-250V use code RN instead of PN *Alternate voltage rating 380-480V use code SE instead of PN Elapsed Time Meters 99999.99 hours, non reset Voltage Frequency Range Hz 110/130V 50 Hz 200/250V 50 Hz 480V 50 Hz 110/130V 60 Hz 200/250V 60 Hz 480V 60 Hz • **

UL Recognized Specify Scale

Elapsed Time Meter

L

70


Crompton AC Overload Ammeters • X6 Overload Scaling for Motor Start Duty

DIN Panel Meters SPECIFICATIONS/ORDERING INFORMATION

• True RMS Reading, Self Contained 50/60Hz • 31/2", 3/16 DIN & 1

/4 DIN sizes

L

Fiesta

Fiesta 31/2" Panel Meter ANALOG METERS

SPECIFICATIONS/ORDERING INFORMATION Accuracy 2.5% shortscale, 1.5% longscale Burden 0.5VA shortscale, 1.5VA longscale Shortscale (90°) Rating Scaling Catalog # 5A 0-5-30A 016-026A-LSLS-C7 10A 0-10-60A 016-026A-MTMT-C7 15A 0-15-90A 016-026A-NDND-C7 20A 0-20-120A 016-026A-NGNG-C7 30A 0-30-180A 016-026A-NLNL-C7 60A 0-60-360A 016-026A-NWNW-C7 80A 0-80-480A 016-026A-PDPD-C7 5A Transformer rated 016-026A-LS**-C7

Longscale (240°) Catalog # 016-036A-LSLS-C7 016-036A-MTMT-C7 016-036A-NDND-C7 016-036A-NGNG-C7 016-036A-NLNL-C7 016-036A-LS**-C7

Class 1.5, Burden 0.5VA (specify 50 or 60Hz) 72x72 Shortscale Rating Scaling Catalog # 5A 0-5-30A E243-026A-LSLS-C7 10A 0-10-60A E243-026A-MTMT-C7 15A 0-15-90A E243-026A-NDND-C7 20A 0-20-120A E243-026A-NGNG-C7 30A 0-30-180A E243-026A-NLNL-C7 5A Transformer rated E243-026A -LS**-C7 96x96 Shortscale Rating Scaling Catalog # 5A 0-5-30A E244-026A-LSLS-C7 10A 0-10-60A E244-026A-MTMT-C7 15A 0-15-90A E244-026A-NDND-C7 20A 0-20-120A E244-026A-NGNG-C7 30A 0-30-180A E244-026A-NLNL-C7 5A Transformer rated E244-026A -LS**-C7 144x144 Shortscale Rating Scaling Catalog # 5A 0-5-30A 246-076-LSLS-C7 10A 0-10-60A 246-076-MTMT-C7 15A 0-15-90A 246-076-NDND-C7 20A 0-20-120A 246-076-NGNG-C7 30A 0-30-180A 246-076-NLNL-C7 5A Transformer rated 246-076-LS**-C7

DIN meters also available with X2 & X5 overload scaling ** state required scaling at time of order

Also available with X2 & X3 overload scaling

Crompton 4-IN-1 Panel Meters • 96mm 1/4 DIN case • Mixed functions

L

SPECIFICATIONS Frequency meter: AC ammeter: Hours run: Hours display: DC current: DC volts: Burden: Current:

110, 120, 200, 230, 240, 380, 400, 415, 440, 480V AC nominal. Maximum end scale 600 volts 45/55Hz, 55/65Hz, 45/65Hz, 360/440Hz 1 or 5A input (from CT) 110, 120, 220, 230, 240, 380, 400, 415, 440 volts; 50 or 60Hz 99999.99 hours 250µA - 1A DC including 1, 5, 10, 20 and 4-20mA DC for transducer inputs 50mV to 600V DC including 50, 60, 75 and 150mV for shunt inputs 0.75VA per phase Hours run: 2.5VA LCD hours run: 0.5VA Voltage: 0.5VA Frequency: 4VA

When ordering please specify the inputs for each parameter and the scaling required.

71

NEW ORDERING INFORMATION

244-80N

AC voltmeter:

72x72 Longscale Catalog # 243-036-LSLS-C7 243-036-MTMT-C7 243-036-NDND-C7 243-036-NGNG-C7 243-036-NLNL-C7 243-036-LS**-C7 96x96 Longscale Catalog # 244-036-LSLS-C7 244-036-MTMT-C7 244-036-NDND-C7 244-036-NGNG-C7 244-036-NLNL-C7 244-036-LS**-C7 144x144 Longscale Catalog # 246-036-LSLS-C7 246-036-MTMT-C7 246-036-NDND-C7 246-036-NGNG-C7 246-036-NLNL-C7 246-036-LS**-C7

Model 244-80C 244-80D 244-80G 244-80H 244-80I 244-80J 244-80K 244-80N 244-80P 244-80Q 244-80R 244-80S 244-80T 244-80U 244-80W 244-80X 244-80Y 244-80Z 244-802 244-803 244-804 244-806 244-807

Description ACV + DCI + ACA + DCA 3 x DCI + DC ETM (LCD) 3 x ACA 3 x ACV + FRQ 3 x ACA + ETM 3 x ACA + ETM (LCD) FRQ + ACV +DCI ACA + ACV + FRQ + ETM 3 x ACV ACV // FRQ // ETM + ACA ACV // ETM + 2 x ACV 2 x ACV + 2 x ACA FRQ // ETM + ACV 3 x ACA + ACV TM // FRQ + DCI + ACV 4 x DCI ETM // FRQ + DCI ACV + ACA + FRQ // ETM 2 x ACV + ACA + ETM ACV + FRQ + 2 x ACA 3 x ACA + DCI 3 x ACV + ACA V, Hz, ETM + SWITCH

ACV = Rectified AC voltmeter ACA = Rectified AC ammeter DCA = DC ammeter DCI = DC indicator ETM = Elapsed time meter ETM(LCD) = LCD elapsed time meter FRQ = Frequency meter // = In parallel with


Crompton DIN Panel Meters L

• 48, 72, 96 & 144mm Case Sizes • 1.5% Accuracy Class • 90° & 240° Versions Moving Coil DC Ammeters and Voltmeters The linear scale is calibrated down to zero & accuracy maintained down to 10%. Accuracy: Class 1.5 Impedance: Voltmeters: 1000Ω/V above 1V Millivolt meters use a 5mA movement. Ammeters: 75mV internal shunt above 60mA 72 x 72 mm

96 x 96 mm

144 x 144 mm

E243-01A E243-01C

E244-01A E244-01C

246-10A 246-10C

E243-01V E243-01N

E244-01V E244-01N

246-10V 246-10N

243-05A 243-05C

244-05A 244-05C

246-05A 246-05C

243-05V 243-05N

244-05V 244-05N

246-05V 246-05N

Suppressed zero (e.g. 4-20mA, 1-5V) models also available. Code EAEA EBEB EIEI EQEQ FAFA FDFD FKFK FXFX GCGC GZGZ HCHC HFHF HJHJ HSHS HZHZ KDKD K JK J KPKP LALA LCLC LFLF LLLL LSLS LWLW MTMT NDND NJNJ NLNL NPNP

DC Voltmeter Range 50 mV 60 mV 75 mV 100 mV 150 mV 250 mV 400 mV 600 mV 1V 1.5 V 2.5 V 4V 5V 6V 10 V 15 V 20 V 25 V 40 V 60 V 100 V 150 V 250 V 400 V 500 V 600 V

Code HYHY JCJC JDJD JRJR JX JX KDKD K JK J KPKP LALA LCLC LFLF LLLL LSLS LWLW MTMT NDND NGNG NJNJ NPNP NWNW PKPK PZPZ RSRS SCSC SFSF SJSJ

Moving Iron AC Ammeters and Voltmeters Meters indicate true RMS values, substantially independent of system waveform. Scales are calibrated down to 20%. Accuracy: Class 1.5 Frequency: 50 or 60Hz (specify) Burden: Ammeters: 0.5VA Voltmeters: 4.5VA maximum Model Code 48 x 48 mm Short Scale (90°) AC Ammeter E242-75A AC Voltmeter E242-75V Long Scale (240°) AC Ammeter 242-03A AC Voltmeter 242-03V AC Ammeter Range 1A 1.5 A 2.5 A 4A 5A 6A 10 A 15 A 20 A 25 A

72 x 72 mm

96 x 96 mm

144 x 144 mm

E243-02A E243-02V

E244-02A E244-02V

246-071A 246-07V

243-03A 243-03V

244-03A 244-03V

246-03A 246-03V

AC Voltmeter Range 150 V 300 V 400 V 600 V

Code LALA LCLC LFLF LLLL LSLS LWLW MTMT NDND NGNG NJNJ

Code PZPZ RXRX SCSC SJSJ

L

DC Ammeter Range 200 µA 250 µA 400 µA 600 µA 1 mA 1.5 mA 2.5 mA 5 mA 6 mA 10 mA 15 mA 20 mA 25 mA 40 mA 100 mA 250 mA 400 mA 600 mA 1A 1.5 A 2.5 A 4A 5A 6A 10 A 15 A 25 A 30 A 40 A

DIN Long Scale

DIN Frequency Frequency Meters Frequency meters use an integral electronic converter and a moving coil indicator. Accuracy: Class 0.5 Burden: 4VA maximum Model Code Short Scale (90°)

48 x 48 mm E242-41S

Range Code 100-125V AC 200-250V AC

55/65Hz PLAN-AN RNAN-AN

45/55Hz PLAG-AG RNAG-AG

72 x 72 mm E243-41S 45/65Hz PLAJ-AJ RNAJ-AJ

96 x 96 mm E244-41S 360/440Hz PLBI-BI RNBI-BI

ORDERING INFORMATION To Order: Specify Model Code followed by Range Code Example: E242-75V-PZPZ General Specifications: Environment: -20°C to +60°C Case: UL94VO polycarbonate case, glass window, IP52 Depth: 64mm Standard dials are white matte with black printed scales and bar knife-edge pointers. Black dials with white or yellow scales and pointers are also available.

72

ANALOG METERS

Model Code 48 x 48 mm Short Scale (90°) DC Ammeters E242-89A Ammeters E242-89C center zero DC Voltmeters E242-89V Voltmeters E242-89N center zero Long Scale (240°) DC Ammeters 242-05A Ammeters 242-05C center zero DC Voltmeters 242-05V Voltmeters 242-05N center zero

L

DIN Short Scale


Hoyt Industrial & Military Panel Meters ORDERING INFORMATION

Round Panel Meters

To Order—Insert Number Code for Each Letter to Select Catalog Number. • Metal or Phenolic Case • 21/2" - 41/2" Sizes • DC & AC Types

A – B – C – D – E

A

• Wide Variety of Options

L

• Military Qualified Versions (21/2" & 31/2") 17/3

B

C

Model 17/3 21/2" DC meter 552 21/2" AC meter 17/L 3" DC meter 560 3" AC meter 582 31/2" DC meter (phenolic case only) 584 31/2" AC meter (phenolic case only) 570 31/2" DC meter (metal case only) 580 31/2" AC meter (metal case only) 574 41/2" DC meter 617 41/2" AC meter Case P Phenolic case WR Wide rim metal case MM Sealed metal case Standard Ranges DC

Scale Specify range and legend

E

Options

250° DC Meters

ORDERING INFORMATION • High Impact Metal Case

To Order—Insert Number Code for Each Letter to Select Catalog Number.

• 2", 3" and 3 - 3/8 " Sizes

A – B – C – D – E Example: 250-20-BL-5mADC-5mADC-RP

• 2% Accuracy • Illumination Option

250

SPECIFICATIONS Movement: Highly damped pivot & jewel Deflection: 250 degrees Accuracy: 2% standard, 1% available Case: Iron case standard, brass case available Dimensions: 250-20 250-30 250-375 3.32" 3.80" Bezel diameter 2.29" Body diameter 2.05" 3.00" 3.36" Depth behind panel 2.51" 2.50" 2.50" Terminals: 10-32 studs Other options: Color bands, white on black dial, bezel style, pointer style.

73

20, 50, 100, 200, 500uA 1, 2, 5, 10, 20, 50, 100, 200, 500mA & 4-20mA 1, 2, 5, 10, 20, 50A 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 500, 750V 10, 20, 50, 100, 200, 500mA 1, 2, 5, 10, 20, 50A 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 600V

AC

D Also available: 6351/2 Series 31/2" Metal Case Sealed Meters for extreme duty applications.

L

ANALOG METERS

SPECIFICATIONS Movement: DC moving coil, AC repulsion Accuracy: 2% of full scale Case: Metal or phenolic, with glass front Dimensions: Bezel dia. Body dia. Depth behind panel 17/3-P, 552-P 2.69" 2.20" 1.88" 17/L-P, 560-P 3.22" 2.50" 1.88" 582-P, 584-P 3.50" 2.75" 1.89" 574P, 617P 4.50" 3.75" 1.95" 17/3-WR, 552-WR 2.55" 2.06" 1.83" 17/L-WR, 560-WR 3.22" 2.50" 1.94" 570-WR, 580-WR 3.66" 3.00" 2.09" 574-WR, 617-WR 4.50" 3.75" 1.89" Terminals: 10-32 studs Options: Color bands, white on black dial, wide or narrow bezel, straight side metal case, LED illumination, 1/4-28 studs, pointer style, pointer color.

Example: 17/3-P-5mADC-300GPM

A

B

C

Model 250-20 2" meter 250-30 3" meter 250-375 3-3/8" meter Bezel BL Black CHR Chrome Standard Ranges DC

D

20, 50, 100, 200, 500uA 1, 2, 5, 10, 20, 50, 100, 200, 500mA & 4-20mA 1, 2, 5, 10, 20, 50A 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 500, 750V

Scale Specify range and legend

E

Options RP BP IL

Red pointer Black pointer Illumination (specify 12 or 24 VDC)


LFE/API Analog Panel Meters Replacements for popular styles and sizes 7000 Series Phenolic case, glass window 21/2" 7025 31/2" 7035 41/2" 7045 51/2" 7055

Meteor Series Plastic window & case 21/2" 204 31/2" 304 41/2" 504 51/2" 604

Panelist Series Black phenolic case, glass window 31/2" 303 41/2" 503 51/2" 603 Clear plastic case & window 21/2" 202 31/2" 302 41/2" 502 51/2" 602

ANALOG METERS

Edgewise Series Plastic window & case 11/2" 1015 21/2" 1025 31/2" 1035 31/2" shielded 371

Ruggedized Series Sealed metal case 21/2" 255 31/2" 355 41/2" 455

Round Series Polycarbonate case, plastic or glass window 31/2" 1235

See more info online at weschler.com/LFE

A&M Ruggedized Panel Meters • Steel Case, Glass Window • Watertight • Magnetic Shielding (90° models) • Mounting per Mil-M-10304E

Style/Size 90° Round 21/2"

31/2"

90° Square 11/2" 21/2"

L

90° Accuracy 90°: 250°:

L

250°

2% DC & Iron Vane, 3% Rectifier Type 1% DC, 2% Rectifier Type

250° Round 21/2" 31/2" 41/2"

To order: specify model, input & scale

Model

Type

263 264 265 266 363 364 365 366

AC Rectifier Type RF Core Magnet DC Core Magnet AC Iron Vane AC Rectifier Type RF Core Magnet DC Core Magnet AC Iron Vane

133 135 233 235 236

AC Rectifier Type DC Core Magnet AC Rectifier Type DC Core Magnet AC Iron Vane

2432 2452 3432 3452 443 445

AC Rectifier Type RF Core Magnet AC Rectifier Type DC Self-shielding AC Rectifier Type DC Self-shielding

74


Hoyt Illuminated Meters Features bright white, even backlighting with no hot spots or shadowing. No holes to drill or bulbs to burn out. 3100 Series

5000 Series

• Window, Surface & Bezel Mount • Many Voltage & Current Ranges • UL Recognition Optional • Accuracy 2% of Full Scale

• Vibration & Harsh Environment Resistant • Many Voltage & Current Ranges • UL Recognition Optional • Accuracy 2%, except Rectifier Type 3%

Size 11/2"

ANALOG METERS

21/2" 31/2" 41/2"

Model 3115 3116R 3125 3126 3135 3136 3145 3146

Type DC Moving Coil AC Rectifier Type DC Moving Coil AC Repulsion DC Moving Coil AC Repulsion DC Moving Coil AC Repulsion

ELumination Lighting (Optional on 3100 & 5000 series meters) Light Intensity: 10–13 ft-L Power Required: 3–18VDC, 60mA max.

Size 11/2" 21/2" 31/2"

Model 5015 5016R 5025 5026 5035 5036

Line Frequency Meters also available To order: Specify model, input & scale

Triplett Analog Panel Meters Replacements for popular styles and sizes G Series Plastic window & case 11/2" 120-G 21/2" 220-G, 230-G 31/2" 320-G, 330-G 41/2" 420-G, 430-G 51/2" 520-G, 530-G

R Series Plastic window & case 41/2" 420-R, 430-R

GL Series Glass window, plastic case 21/2" 220-GL, 230-GL 31/2" 320-GL, 330-GL 41/2" 420-GL, 430-GL 51/2" 520-GL, 530-GL

Phenolic Series Glass window, phenolic case 21/2" rectangular 227-T, 237-S 31/2" rectangular 327-T, 337-S 41/2" rectangular 420, 430 61/2" rectangular 626, 636 21/2" round 221-T, 231-S 31/2" round 321-T, 331-S

GL/B Series Glass window, plastic case, integral bezel 31/2" 320-GL/B, 330-GL/B 41/2" 420-GL/B, 430-GL/B 51/2" 520-GL/B, 530-GL/B

Ruggedized Series Plastic window, steel case, sealed 11/2" rectangular 127-HR 21/2" round 221-HR 31/2" round 321-HR

See more info online at weschler.com/triplett

75

Type DC Moving Coil AC Rectifier Type DC Moving Coil AC Repulsion DC Moving Coil AC Repulsion


Simpson Analog Meter Relays • Commercially Sealed Moisture and Dust Proof • Single and Dual Set Points • Calibration not Affected by Steel Panel Mounting • Rugged Metal Case for Rigorous Environments • Wide Variety of Control, Alarm and Limit Use • Relays Can Be Set for Manual or Automatic Reset

Rugged Seal

ANALOG METERS

The 33 Series instruments offer a wide variety of applications in control, alarm and limit use. Photo conductor sensing eliminates all interference with the indicating meter. These relays incorporate an amplifier input which drives a rugged high torque pivot and jewel or taut-band meter. Metal cased construction withstands rigorous environmental conditions. The metal cover with a drawn steel rear case gives complete magnetic isolations. In addition, each meter is moisture, dust, and dirt proof and recommended for use in wash down areas.

L 33 Series

SPECIFICATIONS Calibration Accuracy: Control Point(s) Adjustment:

Switching: Differential: Frequency Response: Relay Contacts: Operation Temperature: Overload (1 second) Overload (Continuous) Power:

±2% of Full Scale (except ±3% for ACA) Single: 0–100% of arc Double, Low limit 0–95% of arc. High limit 5–100% of arc. Adjustable within 4° of each other Within 1% of indication “ON”, “Off” difference is within 0.5% of FS 50–1000 Hz 5 amps, 115 VAC 5° to 55°C 10 Times Full Scale Rating 1.5 Times Full Scale Rating 108–132 VAC, 50–400 Hz

SPECIFICATIONS Range DC Millivoltmeters 0–50 DC Volts 0–1 0–50 DC Milliammeters 0–1 AC Voltmeters 0–10 0–150 0–300 AC Ammeters 0–5

Scale

Model 3323 31⁄2" SSP Cat. #

Model 3323 31⁄2" DSP Cat. #

Model 3324 41⁄2" SSP Cat. #

Model 3324 41⁄2" DSP Cat. #

0–50

21663

21623

21670

21630

0–1 0–50

21664 21665

21624 21625

21671 21672

21631 21632

0–1

21661 Model 3343 31⁄2" SSP

21621 Model 3343 31⁄2" DSP

21668 Model 3344 41⁄2" SSP

21628 Model 3344 41⁄2" DSP

0–10 0–150 0–300

21675 21676 21681

21635 21636 21641

21679 21680 21682

21639 21640 21642

0–5

21673

21633

21677

21637

76


Crompton Meter Relays

ANALOG METERS

• Monitors and Controls Any Variable Which Can be Converted Into an AC or DC Signal • Rugged Shock and Vibration Resistant Design • Indicator, Relays and Power Unit in One Housing • Control Function Continues if the Indicator Becomes Damaged • Stable Electronic Switching Circuit Does Not Use Lamps, Photocells, Inductors or Capacitors • Taut Band, Fluid Damped Indicator • Isolated Input Signal • LED Relay State Indicators Series 239 and 077 meter relays combine a highly accurate indicator with High and Low set point relays. The relays can operate alarm and control devices when the monitored signal value moves outside the chosen set point limits shown by adjustable red index pointers. A single compact case houses the unit which requires only the input signal and power supply thus saving space and installation time.

239

L

SPECIFICATIONS External Power Supply An External AC or DC supply is required for operation of all Meter Relays and must be specified at the time of ordering. AC – Standard Unit will accept 120V or 240V, 60 Hz (Selectable internally at factory) DC – 12V, 24V, 48V and125V DC Note: External Supplies derived from rectified AC must be externally filtered to minimize Ripple Content.

Scales: Standard Scales may be selected from the 1, 1.5, 2, 3, 4, 5, 6, 8, 10 and multiples of 10 or 100 in standard face type. Any caption using standard face type may be specified. Center zero scales are standard where the end value is listed in the above series.

Input Signal Ratings Frequency Monitoring: DC Voltage: DC Current: AC Voltage: AC Current: Thermocouples: RTD Operation: Overloads: Damping Time: Operating Time: Relay Operation: Contact Rating:

Relay State Indicators: Red LED relay state indicators are fitted in dial as standard at no extra charge.

Ordering Information:

77

L

Due to the Versatility of this product it is difficult to list the complete part numbers for all the various functions. Please provide the basic catalog number listed above, along with input, scale, frequency, external power supply, and any options (see table below) you may require. We will then generate a complete part number.

077

45/65 Hz or 55/65 Hz 10 mV to 800V, 1K ohm/V 1 uA to 15A, 20 mV drop 10V to 600V 1K ohm/V 1A to 15A, 5A CT Operation Standard Outputs Min. 10 mV Span 10 Ohm Copper, 100 Ohm Platinum 1.2 x continuous, up to 200V or 100 mA 10 x for 10 seconds 1 Second 250 ms to 10 sec adjustable (077) 250 ms to 20 sec adjustable (239) SPDT contact on each setpoint (DPDT on 239) 5A, 250V, 1000W non-inductive


Crompton Meter Relays 239 SERIES ORDERING INFORMATION 239-302A 239-301A 239-307A 239-300A 239-30TA 239-30RA 239-304A 239-305A

2 Output Relays, 2 Set Points, High/Low Control 1 Output Relay, 1 Set Point, High Control Only 1 Output Relay, 1 Set Point, Low Control Only 1 Output Relay, 2 Set Points, High/Low Control 2 Output Relays, 2 Set Points, High/Low Control, Thermocouple Applications Fitted with Cold Junction Compensation Circuitry 2 Output Relays, 2 Set Points as 239-30TA but for RTD Applications 2 Output Relays, 2 Set Points, High Relay Downscale Energized, Low Relay Upscale Energized 2 Output Relays, 2 Set Points, both Relays Downscale Energized

Note: Specify Calibration Information (See below Ordering Information)

ANALOG METERS

239 Terminal Diagram

077 SERIES ORDERING INFORMATION 077-302A 077-301A 077-307A 077-300A 077-30TA 077-30RA 077-303A 077-304A 077-305A

2 Output Relays, 2 Set Points, High/Low Control 1 Output Relay, 1 Set Point, High Control Only 1 Output Relay, 1 Set Point, Low Control Only 1 Output Relay, 2 Set Points, High/Low Level Control 2 Output Relays, 2 Set Points, High/Low Control, Thermocouple Applications (Specify Type), Fitted with Cold Junction Compensation Circuitry 2 Output Relays, 2 Set Points, as 077-30TA, but for R.T.D. Applications (Specify 10 ohm Copper or 100 ohm Platinum) 2 Output Relays, 2 Set Points, both Relays Upscale Energized 2 Output Relays, 2 Set Points, High Relay, Downscale Energized, Low Relay Upscale Energized 2 Output Relays, 2 Set Points, both Relays Downscale Energized

077 Terminal Diagram

Note: Specify Calibration Information (See below Ordering Information)

OPTIONAL EXTRAS Description Code 4-20 mADC Suppressed Zero Input HG 5 AAC input - A 5A/10A internal CT is fitted permitting connection to the secondary of any of an external instrument transformer LS Latching on both relays (specify reset operation) Consult Mirror Dial Consult Thumb Screw Set Point Adjuster(s) FK Expanded Scale Off-Set Zero Scale Time Proportional Control-Models 239-30T and 239-30RA TP Extended Operating Temperature Range (-25 to +60째C) ET 12V, 24V, 48V External Power MU, BD, BE 125 VDC External Poewer BI Retrofit Mounting Plate Allows Model 239 to be mounted in place of Model 237 using same holes RP Double Pole, Double throw relays have 0.3 to 20 Second Adjustable Time Delay as Standard Other options and special features available upon request

Low relay activates when signal is below setpoint. High relay activates when signal is above high setpoint.

78


LFE Analog Optical Meter Relays • • • • •

31/2" & 41/2" Sizes Plug-In Control Module Plastic Front and Base Proven Optical Setpoints On/Off or Alarm Control

RANGES AVAILABLE

Plug-in control module mounts directly on rear of meter relay or may be remotely mounted with accessory cable.

DC Ranges DC Microamps DC Milliamps DC Amps DC Millivolts DC Volts Process Ranges DC Milliamps

L 195 Series

ANALOG METERS

SPECIFICATIONS Accuracy Ranges Power Setpoint Relay

Size (H x W x D)

DC Volts

±2% DC, ±3% AC see table 120V AC, 50/60Hz High, Low or Double DPDT per setpoint 5A @ 120VAC resistive 2A @ 28VDC resistive 1953: 3.5" x 3.5" x 2.9" 1954: 4.41" x 4.48" x 2.9" add 3.85" depth for control module

Hioki Meter Relays

AC Ranges (Rectifier type) AC Microamps AC Milliamps AC Amps AC Volts

NEW

• Illuminated Dial

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number . A A

• One or Two Form C (SPDT) Relays • Relay Operation Delayed at Power-up

L 2104 SPECIFICATIONS

Panel cutout:

79

100 to 1000 1 to 50 5 1 to 500

More information online at weschler.com/LFE

• Ultra-sensitive 1 µA, 10 mV DC Movements

Type: Minimum H/L interval: Relay power up delay: Relay output response: Contact rating: Power supply: Dimensions:

1-5 4-20 10-50 1-5 0-10

196 Series also available. Made in USA

• Electronic Design for High Accuracy and Repeatability

Meter class: Setting accuracy: Sensitivity:

50 to 1000 1 to 1000 1 to 50 20 to 1000 1 to 750

±2.5% class on 2103; ±1.5% class on 2104 ±1.5% of scale length DC & AC ammeters: 50mV DC Voltmeters: 10kΩ/V, except 100kΩ/V below 500mV FS AC Voltmeters: 1kΩ/V, excpet 10kΩ/V below 500mV FS AC meters are rectifier type Within 3% of scale length Approx. 2 second Approx. 0.5 second 5A@250V AC, 30V DC, resistance load 120 or 240V AC ±10% 2103: 3.31"W x 2.83"H x 4.63"D (84 x 72 x 118 mm) 2104: 4.12"W x 3.48"H x 4.63"D (105 x 89 x 118 mm) 2.8"W x 2.53"H (71 x 64mm)

B

C

D

B – C – D

Example: 2103HL-120-500mVDC

Model 2103 3" meter relay 2104 4" meter relay Contact Type H One relay, activate above setpoint L One relay, activate below setpoint HL One H relay and one L relay Power Supply 120 120VAC ±10% 12 12VDC 240 240VAC ±10% 24 24VDC Range (self-contained): DC 1, 10, 20, 50, 100, 200, 500µA 1, 2, 5, 10, 20, 50, 100, 200, 500mA & 4-20mA 1, 2, 5, 10, 20A 10, 30, 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300V & 1-5V AC 200, 500µA 1, 2, 5, 10, 20, 50, 100, 200, 500mA 1, 2, 5A 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300V

Full scale >300V available on request. For full scale >20A DC, use external shunt with 50mV DC meter. For full scale >5A AC, use external CT with 1A or 5A AC meter. Op tions: Zero center, expanded scale


LFE Analog Optical Meter Relays Series Analog Optical Meter-Relays 195 Series Optical Meter-Relays • • • • •

Plug-In Control Module Long Life Lamp Operation Plastic Front and Base Proven Optical Setpoints On/Off or Alarm Control

196 Series Optical Meter-Relays • • • •

Modern Rectangular Appearance Plug-In Control Module Proven Optical Setpoints Limit Lights & Manual Reset Switches Optional (Model 1967)

The 195 Series and 196 Series Meter-Relays contain an exclusive light sensitive transistor switch that provides the ultimate in control simplicity and reliability. This switch controls the load relays. There are no pointer contacts or mechanical interference in the meter mechanism. The controllers are supplied with a plug-in control module that mounts directly on the rear of the Meter-Relay or may be remotely mounted with an accessory cable.

OPTICAL METER-RELAYS—195 & 196 SERIES SPECIFICATIONS

Accuracy: Balance: Repeatability: Resistance Tolerance: Overload Capacity

1 Second

DC Ranges Current Voltage ±2% ±2% ±1% ±1% ±2% ±2% ±20% ±5% 1000%

AC Ranges (Rectifier Type) Current Voltage ±3% ±3% ±1% ±1% ±2% ±2% — <10V ±20% ≥10V ±5% 150% 150% 150% 150% 150% 60 Hz 60 Hz 20% 20% 3 sec 3 sec

≤100V 1000% >100V 200% Continuous 150% 120% Calibration Frequency: N/A N/A Overshoot (maximum): 20% 20% Response Time (maximum): 3 sec 3 sec Supply Power: 120 VAC 50/60 Hz 7 VA MAX Load Relay Rating: DPDT 5A @ 120 VAC Relative (Model 1967-SPDT only)

Effects of shock, vibration, humidity and temperature are equal to or better than ANSI C39.11981. Safety (dielectric test, leakage and other hazards): instruments are equal to or better than ANSI C39.5-1974. The above tolerance limits apply to the standard ranges listed in this bulletin. Special instruments may vary from these limits. Rated circuit to ground voltage=800 RMS (1100 Peak). *Depth = Front of Panels to End of Terminals

79a

196

DIMENSIONS 196 Series Dimensions Model Height Width Depth* 1963 (312⁄ ")3.006 3.756 2.897 1964 (412⁄ ")3.756 4.632 2.897 195 Series Dimensions Model Height Width Depth* 1953 (312⁄ ") 3.50 1954 (412⁄ ") 4.41

3.50 4.85

2.897 2.897

Depth w/Module* 6.745 6.745 Depth w/ Module* 6.745 6.745

OPTIONS (WHERE APPLICABLE) Setpoint Stop (Sgl or Dbl) Screwdriver Adjust Non-listed Ranges Suppressed Ranges Stabister Protection: DC (Left or right) DC (zero center) AC AC or DC Voltmeters w/cal. adjust pot One-time eng. charge for “customer specials” Double High or Double Low or Double Reversed


LFE Analog Optical Meter Relays AC Ranges On/Off Control, Single High Setpoint Range Part Number Micromperes 0-500 XX-14EM-EM00 0-800 XX-14EW-EW00 Milliamperes 0-1 XX-14FA-FA00 Amperes Transformer Rated 0-5 XX-14LA-LS00 0-10 XX-14LS-MT00 0-15 XX-14LS-ND00 0-20 XX-14LS-NG00 0-25 XX-14LS-NJ00 0-30 XX-14LS-NL00 0-40 XX-14LS-NP00 0-50 XX-14LS-NT00 0-75 XX-14LS-PB00 0-100 XX-14LS-PK00 0-150 XX-14LS-PZ00 0-200 XX-14LS-RL00 0-250 XX-14LS-RS00 0-300 XX-14LS-RX00 0-400 XX-14LS-SC00 0-500 XX-14LS-SF00 0-600 XX-14LS-SJ00 0-800 XX-14LS-SN00 Volts 1000 Ohms/Volt 0-10 to 0-300 (See Note) 0-150 XX-15PZ-PZ00 Note: Order by Description

DC Ammeters 50 mV Shunt-Rated On/Off Control, Single High Setpoint Scale Part Number Amperes 0-1 XX-11EC-LA00 0-2 XX-11EC-LE00 0-3 XX-11EC-LJ00 0-5 XX-11EC-LS00 0-7.5 XX-11EC-MF00 0-10 XX-11EC-MT00 0-15 XX-11EC-ND00 0-20 XX-11EC-NG00 0-30 XX-11EC-NL00 0-40 XX-11EC-NP00 0-50 XX-11EC-NT00 0-60 XX-11EC-NW00 0-75 XX-11EC-PB00 0-80 XX-11EC-PD00 0-100 XX-11EC-PK00 0-150 XX-11EC-PZ00 0-200 XX-11EC-RL00 0-250 XX-11EC-RS00 0-300 XX-11EC-RX00 0-400 XX-11EC-SC00 0-500 XX-11EC-SF00 0-600 XX--11EC-SJ00 0-800 XX--11EC-SN00 0-1000 XX--11EC-VA00 0-1200 XX--11EC-VB00 0-1500 XX--11EC-VC00 0-2000 XX--11EC-VE00

DC Ammeters 100 mV Shunt-Rated On/Off Control, Single High Setpoint Scale Part Number Amperes 0-1 XX-11GB-LA00 0-2 XX-11GB-LE00 0-3 XX-11GB-LJ00 0-5 XX-11GB-LS00 0-7.5 XX-11GB-MF00 0-10 XX-11GB-MT00 0-15 XX-11GB-ND00 0-20 XX-11GB-NG00 0-30 XX-11GB-NL00 0-40 XX-11GB-NP00 0-50 XX-11GB-NT00 0-60 XX-11GB-NW00 0-75 XX-11GB-PB00 0-80 XX-11GB-PD00 0-100 XX-11GB-PK00 0-150 XX-11GB-PZ00 0-200 XX-11GB-RL00 0-250 XX-11GB-RS00 0-300 XX-11GB-RX00 0-400 XX-11GB-SC00 0-500 XX-11GB-SF00 0-600 XX-11GB-SJ00 0-800 XX-11GB-SN00 0-1000 XX-11GB-VA00 0-1200 XX-11GB-VB00 0-1500 XX-11GB-VC00 0-2000 XX-11GB-VE00

ORDERING GUIDE Model Number 1953 1954 1963 1964

Part Number Prefix Change XX to V3 Change XX to V4 Change XX to W3 Change XX to W4

195 & 196 SERIES METER RELAY ACCESSORIES AND OPTIONS Accessories/Parts Description Part Number Control Module (Factory Style #3) High Setpoint 8889-0003 Low Setpoint 8889-2003 Double Setpoint 8889-3003 Control Modules (Factory Style #2) High Setpoint 8889-0001 Low Setpoint 8889-2001 Double Setpoints 8889-3001 Remote Mounting Kit Complete Kit 1125-426 Kit w/o cable 1125-425 New Style Lamp/Holder Assembly 1207-246 Current Transformers (20 mA AC Secondary) Primary Rating: 5A 2062-0150

ANALOG METERS

DC Ranges On/Off Control, Single High Setpoint Range Part Number Microamperes 0-50 XX-10CY-CY00 50-0-50 XX-16CY-CY00 0-100 XX-10DR-DR00 0-200 XX-10EA-EA00 0-500 XX-10EM-EM00 Milliamperes 0-1 to 0-800 (See Note) 0-1 XX-10FA-FA00 0-5 XX-10FX-FX00 0-10 XX-10GZ-GZ00 0-500 XX-10KM-KM00 Amperes 0-1 to 0-50 (See Note) 0-5 XX-10LS-LS00 0-20 XX-10NG-NG00 0-50 XX-10NT-NT00 Millivolts (Shunt Rated) 0-50 XX-11EC-EC00 0-100 XX-11GB-GB00 Millivolts (For Transducer Applications) 0-50 XX-12HY-HY00 0-100 XX-12JR-JR00 Volts 1000 Ohms/Volt 0-1 to 0-600 (See Note) 0-150 XX-12PZ-PZ00 0-300 XX-12RX-RX00 0-600 XX-12SJ-SJ00

195 & 196 OPTIONAL SETPOINTS Range Part Number Single Low Setpoint Same as Single Same as Single High High Setpoint Setpoint Models Except Models Change digit #3 from 1 to 2 Double Setpoint Same as Single Same as Single High High Setpoint Setpoint Models Except Models Change Digit #3 from 1 to 3 Models Manual Reset Pushbutton and Alarm Lights 4 1/2 inch Model Digit 1 & 2 changes 196 ONLY 1964 from W4 to W7 Changes to 1967

Same as Single High Setpoint Models

Single High Setpoint

Single Setpoint Double Setpoint

79b


WESCHLER INSTRUMENTS Reference Only - Call for Suitable Replacements

Beede Analog Meter Relays MR4—Versatile Relay in Rugged Housing for Hostile Environments • • • • • • • •

Display: Analog Pointer Style Case Size: Available in 3- or 4-Inch Case Optical, Noncontacting Setpoints Solid-State Optics—Completely Immune to Ambient Light Long-Life, Solid-state, Infrared LED Light Source Setpoint Control Knobs Designed for Rough Handling Optional, Remote Mounted Relays Available with High-Impact Resistant, Noryl Resin Cover or Clear Lexan • Single or Dual Setpoints • Wide Variety of Relay Logic Available

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: MR4-23-07-0/5 AAC-B-04-FS(0-150 AC Amperes) Model – Table A

Table A 3-Inch

Range/Scale – Table B

MR4

Options Table C

Model Style Setpoints MR4-13-07 Centurion 1 MR4-23-07 Centurion 2 MR4-13-13 QA-Lexan 1 MR4-23-13 QA-Lexan 2 4-Inch MR4-14-07 Centurion 1 MR4-24-07 Centurion 2 MR4-14-13 QA-Lexan 1 MR4-24-13 QA-Lexan 2 MR4-14-05 Motor Load 1 MR4-24-05 Motor Load 2 Table B Standard Ranges AC Milliamperes 0-50 mAAC, 0-100 mAAC, 0-500 mAAC AC Amperes 0-1 AAC, 0-2.5 AAC, 0-5 AAC AC Volts 0-150 VAC, 0-300 VAC, 0-600 VAC Frequency 45-55 Hz, 46-65 Hz, 55-65 Hz AC Motor Load** Adjustable from 0.5 AAC to 7.5 AAC Table C (Options) Single Double Setpoint Setpoint Power, 12 VDC to 24 VDC A-01 A-01 Power, 11 VAC to 30 VAC A-06 A-06 Relay Logic, High-High — B-02 Relay Logic, Low-Low B-04 B-04 Relay Logic, Delayed B-05 B-05 Relay, Dual Setpoint DPDT C-21 Relay, Delayed Latch* H-10 H-12 Alarm Lights* D-01 D-03 Manual Reset Switch* D-04 D-05 Setpoints, Screwdrive Adjust* F-01 F-01 Terminal Safety Cover F-07 F-07 Dustproof & Splashproof Resistant F-10 F-10 * Per Setpoint ** MR2 Style, 4-Inch Only S Standard (Input Range and Scale are the Same) FS Factory Scaling (custom-specify scaling)

SPECIFICATIONS Display Power Accuracy Coincidence Operating Temperature Relays

Failsafe Logic Mode Size Centurion Type (Noryl Resin) 3-inch 4-inch QA Type (Clear Lexan) 3-inch 4-Inch AC Milliamp AC Volts (Rectified) AC Motor Load Current AC Current Frequency

Analog pointer style 115/230 VAC @ 47 Hz–63 Hz, 12V–24 VDC optional ±2% of full scale ±1% of operating span -20°F–165°F 5A @ 115V–230 VAC, gold-plated contacts Single setpoint 1 DPDT Dual setpoint 2 SPDT Standard

3.13" H x 3.24" W x 5.245" D 4.21" H x 5.03" W x 5.245" D 2.90" H x 3.73" W x 5.58" D 4.07" H x 5.19" W x 5.58" D 0-50, 0-100, 0-500 0-150, 300 or 600 0.5A-7.5A 0-1, 0-5, 0-10 55 to 65 Hz

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com

79c


WESCHLER INSTRUMENTS Triplett Analog Panel Meters

Reference Only - Call for Suitable Replacements

G Series Models: 120-G (11⁄2"), 220-G/230-G (21⁄2"), 320-G (31⁄2"), 420-G/430-G (41⁄2")

320G • Four Stud Mounting • Taut Band Suspension Standard for Sensitive Ranges • Standard Indication Accuracy of ±2% for AC & DC • Customized Scales Available • 51⁄ 2" Models Available • Special Pointers and Other Options Also Available Range Res. (Ω) 230-G 330-G 430-G AC Milliammeters 0-10 4000 153-0142 153-0107 153-0114 0-50 120 153-0147 153-0112 153-0119 0-100 40 153-0149 153-0128 153-0135 0-250 5.9 153-0152 153-0131 153-0138 0-500 1.55 153-0155 153-0133 153-0140 AC Ammeters 0-1 .38 153-0001 153-0008 153-0015 0-2 .092 153-0003 153-0010 153-0017 0-3 .039 153-0005 153-0012 153-0019 0-5 .014 153-0006 153-0013 153-0020 0-10 .004 153-0065 153-0058 153-0044 0-15 .003 153-0066 153-0059 153-0045 0-25 .002 153-0068 153-0061 153-0047 0-30 .001 153-0069 153-0062 153-0048 0-50 .00035 153-0070 153-0063 153-0049 A basic 0-50 Ampere AC instrument; dial reads “AC Amperes”, transformer not included 0-75 — 53-1099 53-1248 53-1177 0-100 — 53-1363 53-1537 53-1464 0-150 — 53-1350 53-1538 53-1249 0-200 — 53-1529 53-1348 53-1534 0-300 — 53-1586 53-1315 53-1389 0-500 — 53-1814 53-1316 53-1371 AC Voltmeters (Ω/V) 0-10 10 153-0072 153-0051 153-0037 0-50 50 153-0077 153-0056 153-0042 0-100 91 153-0022 153-0027 153-0032 0-150 125 153-0023 153-0028 153-0033 0-250 144 153-0025 153-0030 153-0035 0-300 144 153-0026 153-0031 153-0036 0-500* 125 153-0214 153-0213 153-0166 *

Model 152-0977 152-0979 152-0981 152-0984 152-0992 152-0994

Res. (Ω) 4000 1170 400 210 2300 825

Range Res. (Ω) 120-G 220-G 320-G 420-G DC Microammeters (Pivot & Jewel) 152-0143 152-0072 152-0001 0-50 2300 152-0977* 0-100 825 152-0979* 152-0145 152-0074 152-0003 0-200 360 152-0981* 152-0147 152-0076 152-0005 0-500 156 152-0984* 152-0150 152-0079 152-0008 DC Microammeters (Taut Band) 0-5 15,000 — 152-1155 52-3071 52-3072 0-10 7,500 — 152-0226 152-0233 152-0240 0-20 2,500 — 152-0228 152-0235 152-0242 0-50 825 152-0992* 152-0231 152-0238 152-0245 0-100 360 152-0994* 152-0247 152-0254 152-0261 0-200 156 — 152-0249 152-0256 152-0263 0-500 40 — 152-0252 152-0259 152-0266 0-1000+ 12.5 — 152-1270 152-1290 152-1344 50-0-50 360 — 152-1236 152-0357 152-1239 DC Milliameters 0-1 55 152-0956 152-0152 152-0081 152-0010 0-5 8.5 152-0961 152-0157 152-0086 152-0015 0-10 3.1 152-0962 152-0159 152-0088 152-0017 0-25 2.0 152-0965 152-0162 152-0091 152-0020 0-50 1.0 152-0967 152-0164 152-0093 152-0022 0-100 .50 152-0969 152-0166 152-0095 152-0024 0-200 .25 152-0971 152-0168 152-0097 152-0026 0-500 .10 152-0974 152-0171 152-0100 152-0029 DC Ammeters 0-1 — 152-0938 152-0173 152-0102 152-0031 0-5 — — 152-0176 152-0105 152-0034 0-10 — — 152-0177 152-0106 152-0035 0-30 — — 152-0182 152-0110 152-0039 A basic 0-50 Millivolt DC instrument; dial reads “DC Amperes”, shunt not included 0-50 — — 52-4142 52-3156 52-4994 0-100 — — 152-1183 152-1294 152-1198 0-150 — — 152-1184 152-1293 152-1199 0-200 — — 152-1185 152-1299 152-1200 0-250 — — 152-1186 152-1312 152-1201 0-300 — — 152-1187 52-3095 152-1202 0-500 — — 152-1188 52-4426 152-1203 0-750 — — 152-1189 152-1345 152-1204 0-1000 — — 152-1190 152-1171 52-3845 DC Millivoltmeters 0-50 6.7 152-0927 152-0183 152-0112 152-0041 0-100 13.5 — — 152-0113 152-0042 0-150 20.2 — — 152-0114 152-0043 DC Voltmeters (Ω/V) 0-5 1000 152-0905 152-0193 152-0122 152-0051 0-10 1000 152-0906 152-0195 152-0124 152-0053 0-25 1000 152-0909 152-0198 152-0127 152-0056 0-30 1000 152-0910 152-0199 152-0128 152-0057 0-50 1000 152-0911 152-0200 152-0129 152-0058 0-100 1000 152-0913 152-0202 152-0131 152-0060 0-150 1000 152-0914 152-0203 152-0132 152-0061 0-200 1000 — — 152-0133 152-0062 0-250 1000 — — 152-0134 152-0063 0-300 1000 — — 152-0135 152-0064 0-500 1000 — — 152-0136 152-0065 0-1000** 2000 — — 152-0138 152-0067 0-5000** 2000 — — 152-0142 152-0071 +Dial Reads 0-1 DC Milliampere **External Multiplier Box - Included

79d WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com


WESCHLER INSTRUMENTS Triplett Analog Panel Meters • Two Stud Mounting (Except 220-GL, 230-GL, Four Stud Mounting). 4 Stud Mounting Available on 320-GL and 420-GL • Taut Band Suspension Standard for Sensitive Ranges • Standard Indication Accuracy of ±2% for AC & DC • Customized Scales Available • 51⁄2" Models Available • Special Pointers and Other Options Also Available

GL-Series

Range Res. (Ω) 230-GL 330-GL 430-GL AC Milliammeters 0-10 4000 53-1956 153-0614 153-0550 0-50 120 53-1957 153-0617 153-0553 0-100 40 53-1958 153-0618 153-0554 0-250 5.9 53-1959 153-0620 153-0556 0-500 1.55 53-1960 153-0621 153-0557 AC Ammeters 0-1 .38 53-1961 153-0605 153-0587 0-2 .092 53-1962 153-0606 153-0588 0-3 .039 53-1963 153-0607 153-0589 0-5 .014 53-1964 153-0608 153-0590 0-10 .004 53-2085 153-0609 153-0591 0-15 .003 53-2086 153-0610 153-0592 0-25 .002 53-2087 153-0611 153-0593 0-30 .001 — 153-0612 153-0594 0-50 .00035 53-2088 153-0613 153-0595 A basic 0-50 Ampere AC instrument; dial reads “AC Amperes”, transformer not included 0-75 — 53-1965 53-1617 53-1837 0-100 — 53-1966 53-1753 53-1610 0-150 — 53-1967 53-1578 53-1759 0-200 — 53-1968 53-1891 53-1915 0-300 — 53-1970 53-1755 53-1561 0-500 — 53-1971 53-1579 53-1603 AC Voltmeters (Ω/V) 0-10 10 53-1972 153-0583 153-0541 0-50 50 53-1973 153-0586 153-0544 0-100 91 53-1974 153-0528 153-0545 0-150 125 53-1975 153-0529 153-0546 0-250 144 — 153-0531 153-0547 0-300 144 — 153-0532 153-0548 0-500* 125 — 153-0680 153-0549 *Required Multiplier Box - Included

Reference Only - Call for Suitable Replacements

Range Res. (Ω) 220-GL DC Microammeters (Pivot & Jewel) 0-50 2300 52-7551 0-100 825 52-7552 0-200 360 52-7643 0-500 156 52-7644 DC Microammeters (Taut Band) 0-5 15,000 52-7645 0-10 7,500 52-7646 0-20 2,500 52-7647 0-50 825 52-7648 0-100 360 52-7649 0-200 156 52-7650 0-500 40 52-7651 0-1000+ 12.5 52-7652 50-0-50 360 52-7653 100-0-100 156 52-7654 500-0-500 12.5 52-7655 DC Milliammeters 0-1 55 52-7548 0-5 8.5 52-7656 0-10 3.1 52-7657 0-25 2.0 52-7658 0-50 1.0 52-7659 0-100 .50 52-7660 0-200 .25 52-7661 0-500 .10 52-7662 DC Ammeters 0-1 — 52-7663 0-5 — 52-7664 0-10 — 52-7665 0-30 — — 0-50 — —

320-GL

420-GL

152-2135 152-2136 152-2137 152-2138

152-2084 152-2085 152-2086 152-2087

152-2054 152-2055 152-2056 152-2057 152-2058 152-2059 152-2060 152-2061 152-2182 152-2183 152-2184

152-2039 152-2040 152-2041 152-2042 152-2043 152-2044 152-2045 152-2046 152-2250 152-2251 152-2252

152-2047 152-2050 152-2051 152-2053 152-2121 152-2123 152-2125 152-2129

152-2032 152-2035 152-2036 152-2038 152-2110 152-2112 152-2114 152-2118

152-2230 152-2232 152-2233 152-2236 152-2237

152-2242 152-2244 152-2245 152-2248 152-2249

A basic 0-50 Millivolt DC instrument; dial reads “DC Amperes”, shunt not included

0-50 — 0-100 — 0-150 — 0-200 — 0-250 — 0-300 — 0-500 — 0-750 — 0-1000 — DC Millivoltmeters 0-50 6.7 0-100 — 0-150 — DC Voltmeters (Ω/V) 0-5 1000 0-10 1000 0-25 1000 0-30 1000 0-50 1000 0-100 1000 0-150 1000 0-200 1000 0-250 1000 0-300 1000 0-500 1000 0-1000* 2000 0-5000* 2000

52-7666 52-7667 52-7668 52-7669 52-7670 52-7671 52-7672 52-7673 52-7674

52-7446 52-6110 52-6381 52-7447 52-7448 52-6108 52-6109 52-7449 52-7450

52-6259 52-6260 52-6261 52-5254 52-6262 52-6263 52-6264 52-7460 52-6266

52-7549 — —

152-2258 152-2259 152-2260

152-2076 152-2240 152-2241

52-7675 52-7676 52-7677 52-7678 52-7553 52-7679 52-7680 — — — — — —

152-2134 152-2077 152-2079 152-2080 152-2223 152-2224 152-2225 152-2226 152-2227 152-2228 152-2229 152-2254 152-2257

152-2097 152-2098 152-2100 152-2101 152-2102 152-2103 152-2104 152-2105 152-2106 152-2107 152-2108 152-2434 152-2437

+Dial Reads 0-1 DC Milliampere

79e WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com


Action Instruments™ DIN Rail Mount Signal Conditioners, Isolators, Alarms, and Power Supplies • Wide Ranging and Field Configurable for Maximum Flexibility • ASIC Based Design for Maximum Reliability • Lifetime Warranty • High Density DIN Rail Mount Saves Panel Space

Ultra SlimPak Ultra SlimPak offers a wide selection of functions, input types and ranges. These modules accept most process signals and output the commonly required voltages, current, and alarm trips.

SPECIFICATIONS Isolation: Humidity: Temperature Range Operating: Storage: Power Consumption: Range: Alarm Relays:

EG12: Agency Approvals:

0 to 55°C -25 to 70°C 1.5W typical, 2.5W Max. 9 to 30 VDC 5A @ 120 VAC or 28 VDC 2A @ 240 VAC SIGNAL CONDITIONERS

Housing: EG8:

1800 VDC between input, output, and power 15 to 95% (@45°C) Operating

0.5"W x 3.54"H x 4.34"D, including rail (12.6 x 90 x 110.2mm) 0.7"W x 3.54"H x 4.34"D, including rail (17.7 x 90 x 110.2mm) CSA per C22.2, UL per UL508, CE

SPECIFICATIONS AND ORDERING INFORMATION Cat # G408

Function Isolator

G108

Limit Alarm

G418

Isolator

G118

Limit Alarm

G428

Isolator

G438

Isolator

Input Span (Field Configurable) 10 mV to 100V DC Volt 1 mA to 100 mA DC Current 10 mV to 200V 1 mA to 100 mA Bipolar switch for ±100% span Platinum RTD RTD 25°C to 800°C Copper RTD 25°C to 468°C B: 500°C to 1820°C E: -150°C to 1000°C Thermocouple J: -200°C to 750°C K: -200°C to 1370°C R/S: 50°C to 1760°C T: -150°C to 400°C Pot 100 ohms to 100k ohms

G448*

Isolator

Strain Gauge

G468

Isolator

G168

Limit Alarm

G128

Limit Alarm

Input

AC Voltage AC Current

G478 Isolator Frequency WV905 Power Supply AC Power *Requires 18-30VDC power supply

0.5 mV/V to 50 mV/V Adjustable Excitation: 1–10 VDC, 120 mA 50 mVAC to 200 VAC 5 mA AC to 5 AAC** 2 Hz to 10 kHz 100 to 240 VAC; 50 to 60 Hz

Housing EG8 EG12

EG12

Output (Field Configurable) DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 0–20 mA, 4–20 mA) Alarm (Dual SPDT Relay)

EG12

DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 0–20 mA, 4–20 mA) Alarm (Dual SPDT Relay)

EG12

DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 0–20 mA, 4–20 mA)

EG12

Alarm (Dual SPDT Relay)

EG8

DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 0–20 mA, 4–20 mA) EG12 DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 0–20 mA, 4–20 mA) EG8 DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 0–20 mA, 4–20 mA) EG12 Alarm (Dual SPDT Relay) DC Voltage (0–5V, 0–10V) EG8 DC Current (0–1 mA, 0–20 mA, 4–20 mA) 17.5mm 24 VDC @ 500 mA **1 to 5AAC range requires C006 0.1Ω shunt

80


Action Instruments™ IQ Signal Conditioners • Multi-Channel DC, RTD, T/C Conditioners—Lower Cost/Point • Ideal for Large Numbers of Data Points • Extreme Operating Temperature—from -40 to 80°C • SnapLoc Terminal Blocks • Optional I/Q Rail Power Bus—Saves Installation Time • Interlocking Modules—Solid, Reliable Mounting

SPECIFICATIONS Isolation: Humidity: Operating Temperature: Power:

SIGNAL CONDITIONERS

HOW TO ORDER—Select the unit with the output of your choice and then add the code that identifies the input range to satisfy your application. Example: Q510-4004 is a 4-channel RTD Input, 2-wire transmitter, with a 0–250°C range and 4–20 mA output.

DC ORDERING INFORMATION 4-20 mA 1-Channel 2-Channel 4-Channel

Q500 -1000 -2000 -4000

DC ORDERING INFORMATION Input Range 4–20 mA 0–10V 0–5V 1–5V

Q501 (1 Ch) -1000 -1003 -1004 -1005

Q501 (2 Ch) -2000 -2003 -2004 -2005

Type J -0001 -0002 — — -0003 —

Type K -0004 — -0005 — — -0006

Q510 Q488

Q520 Q438 Q448

Input Type DC Current DC Current DC Volts 3-wire RTD Pt100Ω TC (B, C, E, J, K, N, R, S, T) Pt RTD (100, 200, 500, 1000), Cu RTD (9), Ni RTD (120), 90mV, 900mV, 4000Ω T/C (J,K,T) Potentiometer Bridge

81

Range 0–20/4–20 mA 4–20 mA 0–5V, 0–10V,1–5V See Below -270 to +1370°C (type K) -200 to +850°C (Pt 100) See Blow 100Ω to 100kΩ ±5mV to ±200mV

Output Channels 0–20/4–20 mA 1, 2 or 4 4–20 mA 1 or 2 4–20 mA 0-1mA, 4-20mA, 0–5V, 0-10V

4–20 mA 0-1mA, 4-20mA, 0–5V, Q478 Frequency 2Hz — 10kHz 0-10V T/C cold junction compensation (standard). Output linear to mV input.

Type T -0007 — — -0008 — —

ORDERING INFORMATION—ACCESSORIES Mounting Hardware MD02 MD03 IQRL-D002 IQRL-D004 IQRL-D008

Q488

ACTION I/Q SIGNAL CONDITIONERS Cat # Q500 Q501

Q520 (T/C) ORDERING INFORMATION Temp Range 0–500°F 0–1000°F 0–2000°F 0–250°C 0–500°C 0–1000°C

L

Response Time: Approvals:

From 1800 to 4000 VDC, input to output and channel to channel 15–90% @ 45°C 40 to 80°C (Q5XX Series) 0 to 55°C (Q4XX Series) 12 to 35 VDC output loop (Q5XX Series) 18 to 30 VDC output common (Q4XX Series) 100 mSec (10–90%) typical UL508, CSA C22.2, CE

TS32 DIN Rail (2m) Slotted (G-rail) TS35 x 7.5 DIN Rail (2m) Slotted (H-rail) IQ Rail for 2 Modules (Q488 only) IQ Rail for 4 Modules (Q488 only) IQ Rail for 8 Modules (Q488 only)

Circuit Type Input Loop Powered Isolated 2-Wire Transmitter

2 or 4 1

2-Wire Transmitter Isolated 2-Wire Transmitter (2, 3 or 4-wire input)

2 1 1

Isolated 2-Wire Transmitter 3-wire to 2-Wire Transmitter Isolated 4-wire to 2-Wire Transmitter Isolated 2-Wire Transmitter

1

Q510 (RTD) ORDERING INFORMATION Temp Range 0–100°C 0–150°C 0–200°C 0–250°C 0–500°C 0–200°F 0–300°F 0–400°F 0–500°F 0–1000°F

Q510 (2-Ch) -0001 -0002 -0003 -0004 -0005 -0006 -0007 -0008 -0009 -0010

Q510 (4-Ch) -4001 -4002 -4003 -4004 -4005 -4006 -4007 -4008 -4009 -4010

Other inputs & AC powered modules also available.


Action Instruments™ Isolating Action Instruments™ DC Input, Field Configurable Isolator Two-Wire Transmitter • Isolated, Linearized Current Loop Output with Math Functions for an RTD or Thermocouple Input • HART Compatible or Field Configurable with Optional Display • Intrinsically Safe Operation or with Display and EP Enclosure • Programmable for 11 T/C Types, 6 RTD Types, mV or Ohm inputs

• Multi-Function, Multi-Channel Input. • DC-Frequency or Frequency-DC Conversion for Totalization/ Integration Applications. • Math Capability Supports Many Process Control Functions. • Switch Selectable or PC Programmable Ranges.

L T79D

The model T798 is a programmable temperature transmitter that can be factory or field configured using the optional 1 or 2 line alphanumeric display. The model T798 is Highway Addressable Remote Transducer (HART) based, temperature transmitter that can be factory or field configured using an optional 1 or 2 line alphanumeric display, optional PC based modem and software. Alternatively an HC275 Hand-Held Communicator loaded with the Action T798 Device Description from the Hart Foundation Library can be used.

The Q498 can perform single or double input math calculations on the input values. The available operators are: +, -, *, /, Sq, Sqroot & Average. Process control functions include Hi/Lo Select, Rate of Change Limiter and Track & Hold. The frequency input can also have the math functions applied. A 25-point linearization function is available for Channel 1 Analog input only. All output math and process control functions require the C698 software.

SPECIFICATIONS Linearization: Thermocouple and RTD linearization to ±0.05°C. Output: Analog, two-wire 4-20 mA Transmitter Accuracy: ±0.05% of the millivolt or ohm equivalent input reading, or the value from the Accuracy Table, whichever is greater; plus ±0.05% of the span. For thermocouples, add ±0.5°C (0.9°F) for cold junction compensation. Output Analog Zero: 100% of Sensor range —Non-interacting Adjustments: Analog Full-scale: Normal or Reverse Acting Operating Temperature: Electronics & Display (with reduced visibility): -40°C to 85°C, (-40°F to +185°F) Display (full visibility): -20°C to +70°C, (-4°F to +158°F)

ORDERING INFORMATION T797-0000 T797-1000 T798-0000 T798-1000 Displays & Options T79D-2000 T79D-1000 T79E-1000 T79A-P000 T79A-D000 T79A-M000 T79A-MH00 T79A-C000

Temperature Transmitter, Non IS Temperature Transmitter, IS-FM/CSA Temperature Transmitter, Hart, Non IS Temperature Transmitter, Hart, IS-FM/CSA Two Line Alphanumeric Display One line alpha-numeric Display Weather Proof Head-Mount Enclosure Pipe Mount Bracket for T79E-0/D only DIN Rail Mounting Kit T797 Configuration Modem T798 Hart Configuration Modem Configuration Software for T797 & T798

SPECIFICATIONS Analog Input Ranges (Two Isolated Channels) Analog Maximum Overload (continuous) Analog Output Ranges Analog Output Drive

±150mV, ±1.5V, ±15V, ±150V ±2.5mA, ±25mA 200V DC for voltage inputs; 170mA DC and/or 60V DC maximum for current inputs (self-resetting fuse) 0-20mA, 0-10V, ±10V 0-20mA: 12VDC compliance. (600Ω maximum) Voltage ranges: 10mA drive (1000Ω load minumum) Analog Output Accuracy ±0.005% of the FS Input Range (±0.05% on 150 volts range), plus ±0.05% of the FS Output Range (±0.1% for output loads <200Ω) Analog Response Time 750msec max. (10-90%) Analog Input Impedance ≥100kΩ on voltage ranges > 1.5V, ≥10MΩ on voltage ranges <1.5V 70Ω typical (non-overload) on all current ranges Analog Output Impedance Less than 3Ω on voltage output ranges ≥ 500kΩ on current output ranges Frequency Input One channel with two voltage range inputs: 150mV to 50Vrms with 5Vp noise suppression, or 0.5V to 150Vrms with 20Vp noise suppression, 2Hz to 10kHz in software selectable ranges. Frequency Output ±0.1%, 2Hz to 10kHz in software selectable ranges Open collector pulled up through 20k to 18V, with 1mA drive.Sinks up to 20mA from 24V external supply. Discrete Input Input active to Common, with soft pull-up (1mA) to +18V CMR (DC to 60Hz) ≥90dB for 60Hz and 120dB @ DC Power Requirements 9-30VDC, 2.5 watts max Isolation Input to Input to Output to Power, 1800VDC Size DIN rail case (0.88" x 4.0" x 4.59") Operating Temperature 0°C to + 55°C (32 to 131°F)

ORDERING INFORMATION Q498-0000 C698-0000 H902 H910 H915

DC–Frequency Isolator Configuration Software & PC Serial Cable 0.2Amp, 24VDC Power Supply 1Amp, 24VDC Power Supply 2.3Amp, 24VDC Power Supply

82

SIGNAL CONDITIONERS

Both the T798 and T797 accept thermocouple (B, C, E, J, K, L, N, R, S, T, U & special) and 2, 3, or 4 wire Platinum RTDs (385 or 392 alpha) as well as millivolt (mV) and resistance inputs.

The Q498 is a DC powered, DIN rail mount, DC input signal conditioner. The unit is fully isolated to 1800V between input, output and power. Two isolated analog inputs each accept either a DC voltage or current. One analog output delivers either DC bi-polar voltage or uni-polar current. The Q498 also has a separated frequency input channel and a frequency output, as well as a discrete input and output channel.


NEW

Selco Transmitters INPUT RANGES

• Miniature Size

Input Type XA - DC Volts/mA

• Variety of Input Types • 1500V Isolation • AC or DC Powered • DIN Rail Mounting

TZ-1XA

SPECIFICATIONS Basic Accuracy: Load/supply variation: Temperature coefficient: Response time: Front adjustments: Insulation resistance: Dielectric strength: Power supply: Operating temperature: Case material: Dimensions (mm):

±0.1% of full scale, except ±0.2% of full scale on CA, DA & EA types ±0.06% of full scale each ±0.02% FS/°C <50ms (0 to 90%) except 500ms on CA type, 700ms on DA & EA types ±5% for zero & span >100MΩ at 500VDC, between input and output or power supply 1 min. at 1500VAC, between input and output or power supply 24VDC ±10% 100-240VAC ±10% -5 to 50°C, <90% RH (non-condensing) Black ABS, 94V-2 25 W x 99 H x 41 D

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: TZ-1XA-22L A A

B

C D

E

B

_

C

D

E

Basic Unit TZ-1 Transmitter, 100-240 VAC powered TZ-5 Transmitter, 24 VDC powered Input Type XA DC Volts/mA FA DC mV/μA EA AC Volts (TRMS, AC coupled, 40-1000Hz) DA AC Amps (TRMS, CT coupled, 40-1000Hz) AA RTD (Pt100, 3-wire, α=385) CA Thermocouple (J, K, R, S or T) BA Potentiometer LA mA loop (TZ-5 only) Input Range Select code from input table for type specified above Output Range Allowable Load 0 0 to 5 VDC >2kΩ 1 1 to 5 VDC 2 0 to 10 VDC >4kΩ for positive output, 3 -10 to +10 VDC >10kΩ for negative output 4 -2 to +2 VDC >2kΩ for positive output, 5 -2.5 to +2.5 VDC >10kΩ for negative output 6 -5 to +5 VDC 7 0 to 4 VDC >2kΩ A 4 to 20 mADC <550Ω B 0 to 20 mADC Response Time (XA & FA types only) L Normal (50 msec) H Fast (1 msec on type XA, 3msec on type FA)

Code 0 1 2 3 4 5 6 7 8 9 A B

Range 0 to 5 VDC 1 to 5 VDC 0 to 10 VDC -10 to +10 VDC 0 to 1 VDC 0 to 100 mVDC 0 to 60 mVDC 0 to 20 VDC -2 to +2 VDC -5 to +5 VDC 4 to 20 mADC 0 to 20 mADC

Input Resistance

>1MΩ

Maximum Input

-50 to +150% of full scale

250Ω

Input Type FA - DC mV/ μA Code 0 1 2 3 4 A B C

Range 0 to 5 mVDC 0 to 10 mVDC 0 to 50 mVDC 0 to 60 mVDC 0 to 100 mVDC 0 to 10 μADC 0 to 100 μADC 0 to 200 μADC

Input Resistance

>1MΩ

Maximum Input

-50 to +150% of full scale

1kΩ 500Ω

Input Type EA - AC Volts Code 1 2 3 4 5

Range 0 to 35 VAC 0 to 100 VAC 0 to 110 VAC 0 to 200 VAC 0 to 220 VAC

Input Resistance >200kΩ

>1MΩ

Maximum Input

150% of full scale or 300VAC

Input Type DA - AC Amps Code 1 2

Range 0 to 1 AAC 0 to 5 AAC

Input Resistance

<0.05Ω

Maximum Input

7.5 AAC

Input Type AA - RTD Code 0 1 2 3 4

Range -50 to +50 °C 0 to 100 °C 0 to 200 °C 0 to 300 °C -20 to +80 °C

Input Resistance

Maximum Input

Pt100 (3-wire)

-50% to 150% of full scale

Input Type CA - Thermocouple Code J0 K2 K3 K4 K5 R0 S0 T0 T1

TC J K K K K R S T T

Range 0 to 1000 °C -50 to +200 °C 0 to 200 °C -50 to +1200 °C 0 to 1200 °C 0 to 1700 °C 0 to 1700 °C -50 to +350 °C 0 to 350 °C

Input Res.

>1MΩ

Max. Input

±150%

Input Type BA - Potentiometer Code 1

Range 0 to 100%

Input Resistance 100Ω to 10kΩ

Input Type LA - mA loop Code A

Range 4 to 20 mADC

Input Resistance 250Ω

Custom ranges for any input type are available on special order.

82a


Selco Signal Conditioners Programmable Transmitter

Signal Isolators

• Change Input and Output Range by Front DIP Switches

• Small Size

• AC or DC Power

• AC or DC Powered (TH) Self-powered (TZ)

• Selectable Filter 50/500msec • Normal or Reverse Output

• Easy Connection • DIN Rail Mount

• DIN Rail Mount

L

TH-2X

TW-4M

SIGNAL CONDITIONERS

SPECIFICATIONS Basic Accuracy: Linearity: Temperature coefficient: Response time: Insulation resistance: Dielectric strength: Power supply: Power consumption: Operating temperature: Maximum input: Dimensions (mm): Connections: Input Range 0 to 5 VDC 0 to 10 VDC 0 to 60 mVDC 1 to 5 VDC -5 to +5 VDC -10 to +10 VDC 4 to 20 mADC 0 to 20 mADC Output Range 0 to 5 VDC 1 to 5 VDC -5 to +5 VDC 0 to 10 VDC -10 to +10 VDC 4 to 20 mADC 0 to 20 mADC

±0.25% FS Less than ±0.1% of full scale ±0.02% FS/°C <50ms (0 to 90%) with filter off >100MΩ at 500VDC, between input and output or power supply 1 min. at 2000VAC, between input and output or power supply 24VDC ±10% 100-240VAC ±10% <80mA (at 24VDC) <50mA (at 100-240VAC) -5 to 50°C, <95% RH (non-condensing) -50 to +150% of range 48 W x 98 H x 41 D M3.5 screw terminals Input Resistance

>1MΩ

250Ω Allowable Load Resistance >2kΩ >4kΩ <550Ω

ORDERING INFORMATION SE/TW-4M-1-N Programmable Transmitter, 100-240 VAC Power SE/TW-4M-4-N Programmable Transmitter, 24VDC Power SE/TZ-41 Signal Isolator, Self powered SE/TH-2X-**L Signal Isolator, AC powered (insert input/output codes) SE/TH-5X-**L Signal Isolator, DC powered (insert input/output codes) Example: SE/TH-5X-42L for 0-1V in and 0-10V out

83

L

TZ-41

L

TZ-41 SPECIFICATIONS Signal input: Signal output: Input current: Load: Voltage loss: Output ripple: Temperature coefficient: Accuracy: Additional error: Operating temperature: Insulation resistance: Dielectric strength: Dimensions (mm):

0 to 20mA, 4 to 20mA, 0 to 5mA Same as signal input (1:1 ratio) Max. 30mA Max. 1000Ω Approx. 3.3V between input and output <0.5% (20mA at 250W) Less than ±100PPM/°C ±0.1% (23 ±1°C) at 250W load +0.1%/100Ω at load <250Ω -0.1%/100Ω at load >250Ω & <600Ω -5 to +50°C, less than 90% RH >100MΩ at 500VDC (input to output) 1 min. at 2kVAC (input to output) 25 W x 98 H x 41 D

TZ-41 will also provide 0 to 5V or 1 to 5V output.

TH-2X & TH-5X SPECIFICATIONS Basic Accuracy: Load/supply variation: Temperature coefficient: Response time: Input resistance: Insulation resistance:

±0.1% of full scale ±0.06% of full scale each ±0.02% FS/°C <50ms (0 to 90%) >1MΩ on VDC, 250Ω on mADC >100MΩ at 500VDC, between input and output or power supply Dielectric strength: 1 min. at 1500VAC, between input and output or power supply Power supply: 24VDC ±10% 100-240VAC ±10% Power consumption: <50mA @ 24VDC, <20mA @ 100VAC Operating temperature: -5 to 50°C, <90% RH (non-condensing) Maximum input: -50 to +150% of range Dimensions (mm): 13 W x 99 H x 115 D In p u t C o d e Rang e In p u t C o d e Rang e 0 0 to 5 VDC 6 0 to 60 mVDC 1 1 to 5 VDC 7 0 to 20 VDC 2 0 to 10 VDC 8 -2 to +2 VDC 3 -10 to +10 VDC 9 -5 to +5 VDC 4 0 to 1 VDC A 4 to 20 mADC 5 0 to 100 mVDC B 0 to 20 mADC O u t p u t C o d e Rang e 0 0 to 5 VDC 1 1 to 5 VDC 2 0 to 10 VDC 3 -10 to +10 VDC A 4 to 20 mADC

Allo wable Load >2kΩ >4kΩ for posivite output, >10kΩ for negative output <550Ω


NEW

Laurel DIN Rail Transmitters • Analog and Pulse Inputs • Serial & Analog Outputs • RS-232 or RS-485 Communications • Dual Relay Outputs • Input/Digital/Analog/Relay Isolation • Free Setup Software The Laureate transmitters provide serial data conversion and analog retransmit for all popular industrial signals. These modules use the proven circuitry of the Laurel panel meters for exceptional accuracy at high update rates.

LTA

L

All Laureate transmitters are easily configured from a PC using the graphical Laurel Instrument Setup Software. The isolated analog output can be digitally scaled to any portion of the full range. Dual relay outputs add alarm and control capability. Programmable modes include operation above or below setpoint, latching or non-latching, hysteresis and band deviation. Each DC transmitter is precalibrated for all DCV & DCA ranges. The user can change the range without recalibration. On the temperature transmitter, thermocouple or RTD type is field selectable. Measurement range can be as wide as the entire span of the sensor type or as narrow as 15°. Cold junction compensation and open sensor detection are included. Standard functions on pulse input models are frequency, rate, period, A to B interval, up/down total to 999999. The extended model provides additional user-configurable functions.

SPECIFICATIONS Digital Output: Protocol: Baud Rate: Accuracy:

ACCESSORIES CBL04 RS-232 cable to PC serial port or USB adpator CBL02 USB to RS-232 cable adapter

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number Order Example: LTA200DCV1 A A

B

C D

B

C

D

Model LTA2 Standard analog inputs LTA4 Extended analog inputs* LTA6 Standard pulse/frequency input** LTA8 Extended pulse/frequency input** Power 0 85-264VAC ±10%, 90-300VDC 1 12-30VAC, 10-48VDC Setpoint Output 1 Dual isolated solid-state relays Input Type (LTA2 or LTA4) DCA4 DCV1 200mV DC RMV1 DCV2 2V DC RMV2 DCV3 20V DC RMV3 DCV4 200V DC RMV4 DCV5 600V DC RMV5 DCV6 300V DC RMV6 DCA1 2mA DC RMA1 DCA2 20mA DC RMA2 DCA3 200mA DC P P1 SG SG1 WM WM1 P385 P392

Process 4-20mA in/out Process Custom mA scaling Strain Gage 200mV Strain Gage Custom Load Cell 20mV Load Cell Custom 100Ω Pt RTD α=385 100Ω Pt RTD α=392

J K R S T E N

SIGNAL CONDITIONERS

RS-232 or RS-485 (2- or 4-wire) Modbus RTU, Modbus ASCII or Laurel ASCII 300-19200 DCV, mA: ±0.01% of FS ±2 counts ACV, mA: ±0.15% of FS ±2 counts (10Hz-10kHz) Strain gage, load cell: ±0.01% of FS ±2 counts RTD: 0.1°C Thermocouple: 0.2°C Update Rate: 50 or 60/sec for analog inputs Load Cell/Strain Gage: 20, 50, 100, 250, 500mV ranges Thermocouple: FS range is maximum for each sensor type Frequency/Pulse Input: AC, magnetic pickups, pulses from NPN or PNP transistors, contact closures, digital logic Channel A Frequency: 0.005Hz to 1MHz Channel B Frequency: 0.005Hz to 250kHz Time Base Accuracy: ±2ppm Signal Level: 12mV min, 250VAC max Update Rate: Gate time + 30ms + 1 period (20/sec at 60Hz) Gate Time: 0.01 to 199.99 sec (selectable) Curve Fitting: Square root extraction standard, Custom curve fitting with LTA8 Quadrature Input: Differential or single ended Transitions Monitored: x1, x2 or x4 Transitions/sec: 250k max. Error Correction: Zero index (Z-channel) Analog Output: 4-20mA, 0-20mA, 0-10V Compliance (mA): 10V (0-500Ω load) Compliance (V): 2mA (>5kΩ load) Accuracy: ±0.02% of span (analog inputs) ±0.01% of span (pulse inputs) Resolution: 16 bits (65536 steps) Power: DC or 47-63 Hz Relay Outputs: Two SPST-NO (Form A) solid-state relays 130mA@140VAC/180VDC Excitation Output: 5V@50mA, isolated 50V from signal gnd (DC, Process & FR 10V@60mA, isolated 50V inputs, jumper 24V@50mA, isolated 50V [DC & Process inputs] selectable) 15V@60mA, non-isolated [FR input] Isolation: 250Vrms power/analog/digital Temperature: 0-55°C operating Size: 120 x 101 x 22.5 mm Mounting: 35mm DIN rail Connections: Detachable screw terminal plugs

5A DC 200mV AC Trms 2V AC Trms 20V AC Trms 200V AC Trms 600V AC Trms 300V AC Trms 2mA AC Trms 20mA AC Trms Type J TC Type K TC Type R TC Type S TC Type T TC Type E TC Type N TC

D

Input Type (LTA6 or LTA8) FR Dual channel frequency/pulse** VF1 4-20mA (process totalizing) VF2 0-1mA (process totalizing) VF3 0-10V (process totalizing) QD Quadrature*** * LTA4 adds custom curve linearization & rate from successive readings. ** LTA6 scalable for frequency, rate, totalizing, timing. LTA8 adds phase angle, duty cycle, up/down counting, rate & total simultaneously, custom linearization, arithmetic functions (A+B, A-B, AxB, A/B, A/B-1). *** LTA6 scalable for position. LTA8 adds scalable rate.

84


Action Instruments™ Low Profile Signal Conditioners • Low Power • Higher Accuracy • Field Configurable • E-Mail Alarm Notification

L

SlimPak II

SPECIFICATIONS

SIGNAL CONDITIONERS

Output: Accuracy (In/Out): Isolation: Operating Temp: Power: Alarm: Size: Approvals:

0-10V, 0-20mA, 4-20mA ±0.015% rng / ±0.05% rng 1800V AC/DC, In/Out/Power 0 to 60°C, <95% RH 9-30VDC, 1W typ. 2 SPDT, 5A@120VAC 0.5" wide DIN rail case UL508, CSA C22.2, CE

ORDERING INFORMATION Model WV408-2000

Function DC

Range ±150mV, 1.5/15/150V, 2.5/25mA +reverse WV418-2000 RTD 2/3/4 wire: Pt100, Cu10 WV428-2000 T/C J,K,T,R,S,E,B,N,C,B WV438-2000 Potentiometer 100Ω to 100kΩ WV448-2000 Bridge ±5/10/20/50/100/200mV (1-10VDC, 120mA excitation) WV468-2000 AC ±50/150/500mV, 5/20/50/150/250V, 20/100mA +reverse (40-400Hz) WV478-2000 Frequency 0-10kHz (150mV-150V) WVC16-2000 Communication Up to 32 modules to Ethernet 10Base-T C650-2000 Software Includes serial cable WV905 Power Supply 24VDC @0.5A Also available as Limit Alarms with latching relays & reset switch

Pyragon Temperature Transmitter • T/C Head Mount • Wide Operating Temperature Range • Factory Configured, Ready to Install

L

2700T

SPECIFICATIONS Input:

T/C J,K,T,E,R,S,B,N,L,U,W RTD Pt, Ni, Cu; 2,3 or 4-wire DC -10 to 70mV, -0.1 to 1.1V Resistance 390Ω, 2200Ω Input Accuracy: 0.1°C (Pt100), 1°C (K T/C) Output: 2-wire, 4-20mA or 20-4mA Output Accuracy: 0.1% of span Resolution: Input 16 bit, Output 12 bit Supply: 8-35VDC Operating Temp: -40 to 85°C, <98% RH condensing Dimensions: 1.73" dia x 1.04" (44x26.3mm) Isolation: 3.75kV AC

ORDERING INFORMATION PY/2700T PY/2750T

Temperature Transmitter (specify input type & range) 2700T with Hart® protocol

NLS Series 8000 Signal Conditioners

L

• Input, Output, Isolation, Power Supply and Special Functions Combined into One Low Cost Modular Unit • Field-Settable Range and Span and Field Configuration • Fuse Protected Linear Power • UL Recognized 8000-1-1 • High Impact, Flame Retardant Polycarbonate Case The Series 8000 signal conditioners are designed with a modular architecture to allow full input, output, and special function selectability and interchangeability. They can also be used as isolators, signal amplifiers, and transmitters. See more information online at weschler.com/nls

85


NLS Series 8000 Signal Conditioners ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 8000-1-1-01(0-27.2V)-60(4-20mADC) A – B – C – D – E A

B

C

Basic and Power—See Base Style Selection Chart 8000-1-1 8–Pin, 120 VAC Power 8000-2-1 11–Pin, 120 VAC Power 8000-3-1 20–Pin, 120 VAC Power 8000-2-2 11–Pin, 240 VAC Power 8000-3-2 20–Pin, 240 VAC Power 8000-1-3 8–Pin, 9–30 VDC Power 8000-2-3 11–Pin, 9–30 VDC Power 8000-3-3 20–Pin, 9–30 VDC Power Input Code 01 DC: Voltage to 300, Current to 100 mA— Specify Range 02 Potentiometer: Any Value from 0–100Ω to 100 kΩ 03 AC: Voltage to 250 V, Current to 100 mA— Specify Range 04 Thermocouple: non-linearized J, K, T, E, R, S, or B— Specify Type and range. See special function "43"for Linearization 05 RTD: Pt100Ω (∝00385), Cu10Ω or Ni120Ω—Specify Type and Range 06 DC Millivolts: 0–200 (8 mV min span)—Specify Range 08 LVDT: 50 mV/V to 800 mV/V RMS—Specify Range 09 Strain Gauge: 2 mV/V to 20 mV/V—Specify Range 10 Frequency: 0–50 kHz (50 Hz min span)—Specify Range 11 Ramp/Soak Programmer 12 High Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range 13 Low Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range 14 Add/Subtract: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range 15 Multiply (A x B)—Specify # of inputs and type 16 Divide (A x B)—Specify # of inputs and type Output Code 60 DC: 0–12V (100 mV min) or 0–50 mA (1 mA min)—Specify Range 70 Frequency: 5V (TTL), 0–50 kHz (11 pulses/hour min)—Specify Range 71 Frequency: Contact Closure 0–2 Hz (11 pph min)—Specify Range 72 Frequency: 24V pulse 0–50 kHz (11 pph min)—Specify Range 73 Valve Positioner: Pot 100-9.9 kΩ, 10k–100 kΩ; 4–20 mADC, 0–1 VDC or 0–10 VDC—Specify feedback type 80 Single Alarm Setpoint: Single Turn Pot. Screwdriver Adj.

D

E

81 Single Alarm Setpoint: Remote 4–20 mADC 82 Single Alarm Setpoint: Remote 1–5 VDC 83 Single Alarm Setpoint: Remote 0–1 VDC 84 Single Alarm Setpoint: Remote 0–10 VDC 85 Single Alarm Setpoint: Multi-turn Pot., Screwdriver Adj. 86 Single Alarm Setpoint: Plus Top Mounted Knob, 0–100% 87 Single Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ 90 Dual Alarm Setpoint: Single Turn Pot. Screwdriver 91 Dual Alarm Setpoint: Remote 4–20 mADC 92 Dual Alarm Setpoint: Remote 1–5 VDC 93 Dual Alarm Setpoint: Remote 0–1 VDC 94 Dual Alarm Setpoint: Remote 0–10 VDC 95 Dual Alarm Setpoint: Multi-turn Pot., Screwdriver Adj. 96 Dual Alarm Setpoint: Plus Top Mounted Knob, 0–100% 97 Dual Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ Special Functions 00 None 40 Square Root 41 Power Term: Nth Power 42 Nth Root: Adjustable root 0.5 to 5 43 Thermocouple Linearization (type/range specified by input code) 44 Curve Fit Linearization: Curve or formula must be provided 45 Ramp Buffer: Delays signal action (adj. 1 sec To 20 min) 46 Peak/Valley Sample Hold: Specify Peak or Valley 48 Rate of Change Processor: (Specify time base, 1 sec etc.) Options for Alarm Setpoints 00 None 01 Low or Low/Low relay sense (Single or dual alarms) 02 High/High relay sense (Dual alarms) 03 Fail-Safe Operation (Dual alarms) 04 Transmitter Output 0–1V output for process, Setpoint #1 and Setpoint #2 (Setpoint output not avail. with strain gage, add/subtract, or high/low select 05 Latching relay(s): Jumper selectable for Latch/Non-Latch 07 Voltage Output (24V @ 15 mA) replaces relay contacts Options for Temperature Inputs 06 Down scale burnout for thermocouple input 08 Differential RTD input: Specify differential range 09 Differential thermocouple input: Specify differential range

BASE STYLE SELECTION CHART Output Code

Type

60

80, 85, 86 90, 95, 96

73, 81, 82, 83, 70 71 60 70, 71 84, 91, 92, 93 72 72 w/46 94; or 80, 85, 86 Input Code 90,95, 96 w/ 07 01/03/04/06/10 DC, AC, Frequency 8 11 20 8 11 11 20 02 Potentiometer 8 20 20 8 20 20 20 05 RTD 20 20 20 8 20 20 20 09 Strain Gauge 11 20 20 11 11 — — 08 LVDT 11 20 — 20 20 — — 15/16 Multiply/Divide 8 20 20 8 20 20 20 12/13/14 High/Low 20 20 20 20 20 — — 11 Ramp/Soak 20 20 — — 20 — — To determine the number of pins required for the signal conditioner, select input code and output code and read across and down. Make sure to order mounting socket.

ACCESSORIES Mounting Sockets—Required and Sold Separately DR011 11–Pin Barrier Terminal Socket for DIN Rail or Flush Mount DR014 Din Rail—Three Foot Length Metal Channel Track DR018 8–Pin Barrier Terminal Socket for DIN Rail or Flush Mount SM004 DIN Rail—Four Foot Length Plastic Channel Track

SM008 SM011 SM020 SX008

8–Pin Barrier Terminal Socket for Channel Track 11–Pin Barrier Terminal Socket for Channel Track 20–Pin Barrier Terminal Socket for Channel Track Explosion Proof Housing (Meets Class1, Group D, Class II, Group E, F, and G)

85a


Pyragon Loop Isolator • Signal Powered CMOS Circuitry • Precise Duplication of Input Signals • 4–20 or 10–50 mA, Same Unit

• High Common Mode Rejection • 1500 VRMS Isolation • Mounts on Bulkhead or in 3" Conduit Box

Provides the Necessary Signal Isolation for Noisy Process Circuits If your process signals are influenced by ground loops, high common mode noise, or other interference, you need the Transmation Model 10 Auto-Isolator. Requiring no separate power supply, Auto-Isolator operates efficiently from input signal current, and precisely retransmits the current applied to the input with an accuracy of ±0.1% of span.

Usable with milliamp signal ranges of 4–20, 10–50, or other ranges between 4 and 50 mA. The instrument can be bulkhead-mounted or installed in a 3-inch cast conduit box. A trim potentiometer, accessible through the instrument’s top plate, permits precise adjustment of current transfer as a function of load resistance up to 500 ohms at 20 mA, and 250 ohms at 50 mA.

10AI

L

SPECIFICATIONS Input: Output Ratings:

ORDERING INFORMATION 10AI 10AI-EXP

Model 10 Auto-Isolator Model 10 in Explosion Proof Housing SIGNAL CONDITIONERS

Accuracy: Size/Weight:

4–20 mA, 10–50 mA, or other spans within range of 4–50 mA 4–20 mA with loads from 0–500 ohms 10–50 mA with loads from 0–250 ohms ±0.1% of span 2.95" diameter, 1.88" high/6 oz

Pyragon Universal Temperature Transmitters • Configurable for Eight T/Cs, 12 RTDs, Millivolts, Ohms • Unmatched Programmability: Input Type, Range, Zero, Span, Linear Output, Engineering Units; Calibration Runs • Exceptionally Economical: Reduces Inventory and Maintenance Costs • Built for Reliability: RFI Protected, Isolated, Environmentally Tough, Five-Year Warranty

SPECIFICATIONS Input Types Thermocouple: RTD:

2800T

L

Types J, K, T, E, R, S, N, B Pt DIN 43760 (50, 100, 200, 500Ω); Pt JIS C 1604 (100Ω); Pt Burns 0.003902α (100, 200, 500Ω); Ni Bristol’s 7NA (110Ω); Ni Minco (120Ω); Cu Minco (10Ω); Cu China 0.00428α (50Ω) mV: -100 to + 100 mV Resistance: 0 to 1000Ω Accuracy: ±0.05% of span ±1 digit Input Span Limits: Any span within range limits Input Resolution: 0.1°, 1 µV, 0.005Ω Output Range: 4 to 20 mA, calibrated; 3.7 to 22 mA, maximum Output Resolution: 0.002 mA RTD Excitation Current: 200 µA, typical Temperature Effect T/C and mV: ±0.2 µV/°C max ±0.005% of input reading/°C RTD and Ω: ±0.002 Ω/°C max ±0.005% of input reading/°C Loop Supply Voltage: 13V + (load resistance x 20 mA), min; 48V, max Size 3.10 x 1.75 x 3.77" HWD

ORDERING INFORMATION 2800T 2800T-EXP 2850T 100665-651 100665-652

Universal Temperature Transmitter, Digital Display (NI FM Approved) 2800T in Explosion Proof Housing 2800T with HART Protocol 32 mm DIN Rail Adaptor—2800T 35 mm DIN Rail Adaptor—2800T

86


Weschler Process Loop Splitter • Three Separate 4 mA to 20 mA Outputs

• DIN Rail Mounting • Screw Terminal Connections • Low Input Resistance

• Flexible and Simple Scaling • Excitation Output • Wide Power Supply Range • Narrower Case than Previous Model

SIGNAL CONDITIONERS

SPECIFICATIONS Input Input Signal: Input Resistance: Excitation Voltage: Output Number of Outputs: Output Range: Adjustability: Accuracy: Speed of Response: Isolation: Drive Capacity: Power Consumption: Operating Temperature: Size (mm): Mounting: Sealing:

The TIM-018 allows one 4 to 20 mA signal to be split into three separate loops. Each output has its own zero and span adjustments, which are accessible from the front panel.

4 mA–20 mA, 0–10 mA 50Ω 20 VDC nominal, 28mA max 3 4 mA–20 mA, 0–10 mA Zero ±1 mA, span ±9 mA ±0.1% of span 200 milliseconds 380V to earth and power 600Ω per loop 3W max 0–50°C, <90% RH non-condensing 22.5 W x 99 H x 111 D DIN rail EN50 022 IP40

All loops are load isolated so an open or short on one loop will not affect the other loops. An internal 20V supply provides sensor excitation.

L

Note: All loop + terminals are internally connected.

TIM018-Mk2

ORDERING INFORMATION TIM018-Mk2-AC TIM018-Mk2-DC

Process Loop Splitter for 95-265VAC operation Process Loop Splitter for 11-30VDC operation

Pyragon Universal Process I/O Module • • • • •

Direct Replacement for Transmation 3000 Series Modules Universal Input Includes TC, RTD, mADC, mVDC 4 Digit Alpha-Numeric LED Display Input Isolated from Output and Power 4 Year Warranty

ORDERING INFORMATION Alarm/Transmitter in Metal Case Alarm/Transmitter w/o case Transmitter Only

L

P3100 P3100-WOC P3100T

The P3100 accepts a wide variety of inputs. The 4 digit display provides a local readout. Use the P3100 in a new installation or to replace existing 3000 series units.

P3100

SPECIFICATIONS Models Replaced: 3510A, 3520A, 3530A, 3540A, 3610A, 3620A, 3630A, 3640A, 3650A, 3660A, 3510DRA, 3520DRA, 3530DRA, 3540DRA, 3610DRA, 3620DRA, 3630DRA, 3640DRA, 3650DRA, 3660DRA, 3510T, 3530T, 3610T, 3630T, 3650T, 3900F, 3909F Input Types J, K, T, E, R, S, B, L, U, N Thermocouple: RTD (2 or 3 wires): 100Ω Pt (α.00385, .00392, .003916); 200, 500 & 1000Ω Pt (α.00385); 120Ω Ni and 10Ω Cu Current: ±20 & ±50mA DC ranges Voltage: ±1 & ±10V DC ranges Millivolts: ±70mV Potentiometer (3 wire) & Resistance (2 wire): 50, 200 & 2000 ranges Frequency: Counts/minute, Hz & kHz ranges

87

4-20mA DC (600Ω Load) or 1-5V DC, 10-50mA DC optional LED Display: 4-Digit Alphanumeric, Decimal Point configurable for 0, 1st, 2nd or 3rd place Front Panel Buttons: Relay Trip & Recovery parameters, Relay states override, Latch reset and output manual mode Analog Accuracy: 0.1% of Span or 10mV referred to input Loop Power: 24VDC supply to power input mA signals up to 21mA DPDT Relay: Configurable delay & latching Working Voltage: 300VAC Input to Output to Input Power Isolation: 1000VDC Input to Output to Input Power Configuration Interface: RS232, 1200 baud, ASCII half duplex Operating Temperature: 0-50°C Power (jumper selectable): 100–240VAC, 50/60Hz and 24VDC ±10% Signal Output:


Laurel Serial to Analog Transmitter

L

• RS-232 & RS-485 Input • Isolated 4-20mA or 0-10V Output • ASCII & Modbus Protocols • AC or DC Power • DIN Rail Mount TS6 • Dual Relay Outputs

NEW

The Laureate serial-to-analog transmitter is able to retrieve digital data from long character strings. You can specify character positions, start and stop ASCII characters, how many characters to skip and how many characters to pass. Modbus RTU, Modbus ASCII and Laurel ASCII protocols are supported. The 16 bit analog output is isolated from the power and digital sections. Span is field adjustable using the Laurel setup software. Update rate to 60/sec provides rapid response.

SPECIFICATIONS Serial Input: Baud Rate: Analog Out: Compliance (mA): Compliance (V): Accuracy: Resolution: Isolation: Relay Outputs:

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: TS602 TS6 A

B

A

B Power 0 85-264VAC ±10%, 90-300VDC 1 12-30VAC, 10-48VDC Setpoint Output 0 None 1 Dual isolated solid-state relays

Accessories: CBL04 CBL02

RS-232 cable to PC serial port or USB Adapter USB to RS-232 cable adapter

SIGNAL CONDITIONERS

Temperature: Size: Mounting: Connections:

ORDERING INFORMATION

RS-232 or RS-485 (2- or 4-wire) 300-19200 4-20mA, 0-20mA or 0-10VDC (selectable) 10V (0-500Ω load) 2mA (>5kΩ load) ±0.02% of span 16 bits 250Vrms power/analog/digital Two SPST-NO (Form A) solid-state relays 130mA@140VAC/180VDC 0-55°C operating 120 x 101 x 22.5 mm 35mm DIN rail Detachable screw terminal plugs

API Frequency to DC Transmitters

L

• 0-1mA, 4-20mA, 0-1V or ±10V Output • 2000V Isolation • Simple field setup (7580) • Input & Output Status LEDs • Functional Test Button 7580 • Lifetime Warranty

These API transmitters accept a frequency input and provide an optically isolated DC voltage or current output that is linearly proportional to the input.

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: API 7010GDU A A

B

B Model API 7010G API 7580G Options A230 D U HC M09 EXTSUP

Accessories: API 008 API 008FS API TK36

Frequency to DC Transmitter, 115VAC, factory ranged Frequency to DC Transmitter, 115VAC, field rangeable Powered by 230VAC ±10%, 50/60Hz, 2.5W max Powered by 9-30VDC, 2.5W typical Conformal coating for moisture resistance High current output to 50mA (7010G only) High voltage output to 24VDC (7010G only) Open collector [sink] output (7010G only) 8-pin octal socket Finger safe 8-pinoctal socket 35mm DIN rail, 39” long, aluminum

Plug-in API transmitters/isolators are available for most sensors & process signals.

Full three-way isolation makes these modules useful for ground loop elimination, common mode signal rejection and noise pickup reduction. The input and output ranges on the 7580 are field configured via switches - no software required. Ranges on the 7010 are factory set and must be specified when ordered. The internal loop supply can be used to power external devices, often eliminating the need for a separate supply.

SPECIFICATIONS 7010 Input Range:

Factory set - specify on order Minimum 0-25Hz, maximum 0-20kHz 7580 Input Range: Field selectable via rotary switches and tables Low range: Min 0-100Hz, max 0-1500Hz High range: Min 0-2kHz, max 0-30kHz Input Voltage: 100mVrms - 150Vrms Input Impedance (min): 10kΩ (7580), 100kΩ (7010) Input Sensitivity: 25mV to 2.5V (pot adjustable) Output Ranges: 0-1V min, 0-10V max, ±1V min, ±10V max (bipolar mode), 0-2mA min, 0-20mA max (current mode). Factory set on 7010 - specify on order, Field settable on 7580 Compliance (mA): 20V, 1000W Output Zero Adjust: ±15% of span Output Span Adjust: ±10% of span Accuracy: Better than ±0.2% of span Response Time (typ): 70msec (7010), 110msec (7580 hi range), 600msec (7580 lo range) Isolation: 2000Vrms power/input/output Loop Supply: 18VDC unregulated, 25mA max. Power (standard): 115VAC ±10%, 50/60Hz, 2.5W max Temperature: -10 to 60°C operating Status Indicators: Variable brightness LEDs indicate level & status Connections: 8-pin octal socket (order separately)

88


Action Instruments Plug-In Signal Conditioners, Isolators and Alarms ENVIRONMENTAL SPECIFICATIONS Isolation Between Input, Output and Power Limit Alarms: 1000 VDC Signal Conditioners: 1500 VDC Temperature Range: Operating: 0 to 60°C Signal Conditioners: 1500 VDC Humidity: 15 to 95% (@45° C) Power: 120 VAC ±10%, 50/60 Hz Consumption: 30W Typical, 5W Max Agency Approvals: CSA per C22.2 and UL per UL508 ActionPak

SPECIFICATIONS AND ORDERING INFORMATION Model # AP4380 AP4390 AP4382 AP1080 AP1090

Function Isolator Single Isolator Dual Isolator (Bipolar Output) Limit Alarm Single Limit Alarm Dual

AP4351

Isolator

AP1280 AP1290

Limit Alarm Single Limit Alarm Dual

AP4081

Conditioner

AP6380

Conditioner

Input DC Volt DC Current

Input Span (Field Configurable) 10 mV to 100V 1 mA to 100 mA

DC Volt DC Current

Bridge

10 mV to 200V 1 mA to 100 mA B: 500°C to 1820°C E: -150°C to 1000°C J: -200°C to 750°C K: -200°C to 1370°C R/S: 50°C to 1760°C T: -150°C to 400°C 10 mV to ±200 mV 50 mV to 200 VAC 5 mA to 100 mA AC 10mA to 100 mA AC 2 Hz to 10 kHz

Thermocouple

AP1690 AP7380

Limit Alarm Single Conditioner

AC Voltage AC Current Frequency

AP7500

Conditioner

DC (Fixed Range)

AP7501

Conditioner

DC (Fixed Range)

AP4003

Conditioner

Potentiometer (Wide Ranging)

Specify: 4–20 mA, 0–10V, 1–5V, 0–5V, 0–10V, or 10–50 mA Specify: 4–20 mA, 0–10V, 1–5V, 0–5V, 0–10V, or 10–50 mA Specify: 0–100% pot 100Ω to 100Ω pots

Output (Field Configurable) DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 4–20 mA) DC Voltage (±5V, ±10V) Single Trip (DPDT, 5A) Single/Dual Trip (2 SPDT, 5A) DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 4–20 mA) Single Trip (DPDT, 5A) Single/Dual Trip (2 SPDT, 5A) DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 4–20 mA) DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 4–20 mA) Single/Dual Trip (2 SPDT, 5A) DC Voltage (0–5V, 0–10V) DC Current (0–1 mA, 4–20 mA) Frequency (0–9 ppm up to 0–10 kHz) TTL: 0/6V Frequency (0–0.12 ppm up to 0–130 ppm) DPDT Relay: 5A Max DC 0-20mA, 4–20 mA, 0–5V, 0–10V

MOUNTING ACCESSORIES FOR ACTION PRODUCTS Mounting Hardware (for ActionPak IQ and SlimPak) MD02 TS32 DIN Rail, 2 Meters, Slotted (G-Rail) MD03 TS35 x 7.5 DIN Rail, 2 Meters, Slotted (H-Rail) Mounting Hardware (for Action Pak Only) MD08 8-Pin DIN Rail Socket (Surface or Rail Mountable) MD11 11-Pin DIN Rail Socket (Surface or Rail Mountable) These sockets mount on standard DIN Rails MD02 or MD03

88a

84


Weschler DC Ammeter Shunts L

MLA

L

Type HA — 1 Through 500 Amperes

HA Type

Lightweight Types

ORDERING INFORMATION Amp 1 2 5 10 20 50 100 200 300 500

Length 6.0" 6.0" 6.0" 6.0" 6.0" 6.0" 6.0" 6.0" 6.0" 6.0"

Width 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25"

C-C Mounting 5.25" 5.25" 5.25" 5.25" 5.25" 5.25" 5.25" 5.25" 5.25" 5.25"

Type HA—50 mV Order Code HA-1-50 HA-2-50 HA-5-50 HA-10-50 HA-20-50 HA-50-50 HA-100-50 HA-200-50 HA-300-50 HA-500-50

L

Type Lab — 10 Through 1000 Amperes

Type HA—100 mV Order Code HA-1-100 HA-2-100 HA-5-100 HA-10-100 HA-20-100 HA-50-100 HA-100-100 HA-200-100 HA-300-100 HA-500-100

Lab Type

TRANSDUCERS / SENSORS

ORDERING INFORMATION Amp 10 15 25 50 100 150 200 250 300 400 1000

Type Lab — 50 mV Length Width 5.0" 1.25" 5.0" 1.25" 5.0" 1.25" 5.0" 1.25" 5.0" 1.25" 5.0" 1.25" 5.0" 1.25" 6.75" 1.87" 6.75" 1.87" 6.75" 1.87" 6.75" 2.37"

Order Code LAB-10-50 LAB-15-50 LAB-25-50 LAB-50-50 LAB-100-50 LAB-150-50 LAB-200-50 LAB-250-50 LAB-300-50 LAB-400-50 LAB-1000-50

Length 6.25" 6.25" 6.25" 6.25" 6.25" 6.25" 6.25" 8.0" 8.0" 8.0" 8.0"

Type Lab — 100 mV Width Order Code 1.25" LAB-10-100 1.25" LAB-15-100 1.25" LAB-25-100 1.25" LAB-50-100 1.25" LAB-100-100 1.25" LAB-150-100 1.25" LAB-200-100 1.875" LAB-250-100 1.875" LAB-300-100 1.875" LAB-400-100 2.375" LAB-1000-100

Type MLC — 800 Through 1200 Amperes

ORDERING INFORMATION– MLC-50 MV Order Code MLC-800-50 MLC-1000-50 MLC-1200-50

Amp 800 1000 1200

Length 4.5" 4.5" 4.5"

Width 2.5" 2.5" 2.5"

Type MLA — 5 Through 150 Amperes

ORDERING INFORMATION– MLC-50 MV Order Code MLA-5-50 MLA-10-50 MLA-15-50 MLA-20-50 MLA-30-50 MLA-50-50 MLA-75-50 MLA-80-50 MLA-100-50 MLA-150-50

Amp 5 10 15 20 30 50 75 80 100 150

Length 2.0" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0"

Width 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25"

Type MLB — 170 Through 600 Amperes

ORDERING INFORMATION– MLB-50 MV Order Code MLB-170-50 MLB-200-50 MLB-250-50 MLB-300-50 MLB-400-50 MLB-500-50 MLB-600-50

Amp 170 200 250 300 400 500 600

Length 3.25" 3.25" 3.25" 3.25" 3.25" 3.25" 3.25"

Width 1.75" 1.75" 1.75" 1.75" 1.75" 1.75" 1.75"

NK Technologies DC Current Transducers SPECIFICATIONS

• Hall-effect sensor and signal conditioner in a single package • Jumper selectable input ranges to 400 A

Output Signal: Output Limit:

L

DT4

ORDERING INFORMATION Order Code DT1-005-24U-U DT1-420-24U-U DT2-005-24U-U DT2-420-24U-U DT3-005-24U-U DT3-420-24U-U DT4-005-24U-U DT4-420-24U-U

89

Description 50, 75, and 100 A Range 50, 75, and 100 A Range 100, 150, and 200 A Range 100, 150, and 200 A Range 150, 225, and 300 A Range 150, 225, and 300 A Range 200, 300, and 400 A Range 200, 300, and 400 A Range

Output 0–5 VDC 4–20 mA 0–5 VDC 4–20 mA 0–5 VDC 4–20 mA 0–5 VDC 4–20 mA

Output Polarity: Accuracy: Power Supply: Power Consumption: Loading: Linearity: Current Ranges: Sensing Aperture: Case: Environmental:

4–20 mA, 0–5 VDC or 0–10 VDC 4-20 mA: 23 mA 0–5 VDC: 5.75 VDC 0–10 VDC: 11.5 VDC Unipolar, Bipolar available 1.0% FS Universal 20–50 VDC, 22–38 VAC, 2VA Max. Power Input and Output Signal are Not Isolated 2 VA 4–20 mA: 650Ω Maximum 0-5VDC: 25kΩ Min. 0-10VDC: 50kΩ Min. 0.75% FS Jumper Selectable 0–400A 0.85" (21.5 mm) Sq UL 94V–0 Flammability Rated -4 to 122°F (-20 to 50°C), 0–95% RH Non-Condensing


Empro Shunts Type A — 20 Through 600 Amperes

ORDERING INFORMATION

Type A

L

Amp 20 50 75 100 125 150 175 200 250 300 375 400 500 600

Type A — 50 mV Length Width 4.125" 0.675" 4.125" 0.675" 4.125" 0.675" 4.125" 0.675" 4.125" 0.813" 4.125" 0.938" 4.125" 0.75" 4.125" 0.813" 4.125" 1.063" 4.125" 1.25" 4.625" 0.938" 4.625" 1.00" 4.625" 1.25" 4.625" 1.50"

Order Code A-20-50 A-50-50 A-75-50 A-100-50 A-125-50 A-150-50 A-175-50 A-200-50 A-250-50 A-300-50 A-375-50 A-400-50 A-500-50 A-600-50

Type A — 100 mV Length Width

Order Code

5.75" 5.75" 5.75"

0.675" 0.675" 0.675"

A-50-100 A-75-100 A-100-100

5.75"

0.93"

A-150-100

5.75" 5.75" 5.75" 6.25" 6.25" 6.25" 6.25"

0.813" 1.063" 1.25" 0.938" 1.00" 1.25" 1.50"

A-200-100 A-250-100 A-300-100 A-375-100 A-400-100 A-500-100 A-600-100

Type B — 300 Through 1000 Amperes

ORDERING INFORMATION Type B

L

Order Code B-300-50 B-400-50 B-500-50 B-600-50 B-750-50 B-800-50 B-1000-50 B-1200-50

Type B — 100 mV Length Width 7.75" 1.75" 7.75" 2.00" 7.75" 2.00" 7.75" 2.00" 7.75" 2.25" 7.75" 2.375" 7.75" 2.50" 7.75" 3.00"

Order Code B-300-100 B-400-100 B-500-100 B-600-100 B-750-100 B-800-100 B-1000-100 B-1200-100

Type C — 1000 Through 2000 Amperes

ORDERING INFORMATION Type C

L

Amp 1000 1200 1500 2000

Type C — 50 mV Length Width 9.063" 2.625" 9.063" 3.00" 9.063" 3.00" 9.063" 3.25"

Order Code C-1000-50 C-1200-50 C-1500-50 C-2000-50

Type C — 100 mV Length Width 10.875" 2.625" 10.875" 3.00" 10.875" 3.00" 10.875" 3.25"

Order Code C-1000-100 C-1200-100 C-1500-100 C-2000-100

Type E — 1500 Through 2000 Amperes

ORDERING INFORMATION Amp 1500 2000

Type E — 50 mV Length Width 9.625" 3.00" 9.625" 4.00"

Order Code E-1500-50 E-2000-50

Type E — 100 mV Length Width 11.25" 3.00" 11.25" 4.00"

Order Code E-1500-100 E-2000-100

Type WT — 600 Through 10000 Amperes Type E

L

Type WT

L

ORDERING INFORMATION Amp 600 750 800 1000 1200 1500 2000 2500 3000 4000 5000 6000 7500 8000 10000

Type WT — 50 mV Length Width Order Code

9.063" 9.063" 9.063" 9.063" 15.625" 15.625" 15.625" 15.625" 15.625" 15.625" 15.625" 16.0"

3.0" 3.0" 3.0" 4.0" 4.0" 4.0" 5.0" 5.0" 6.0" 6.0" 6.0" 8.0"

WT-1000-50 WT-1200-50 WT-1500-50 WT-2000-50 WT-2500-50 WT-3000-50 WT-4000-50 WT-5000-50 WT-6000-50 WT-7500-50 WT-8000-50 WT-10000-50

Type WT — 100 mV Length Width 12.0" 3.0" 12.0" 3.0" 12.0" 3.0" 12.0" 3.0" 12.0" 4.0" 18.5" 4.0" 18.5" 4.0" 18.5" 5.0" 18.5" 5.0" 18.563" 5.0" 18.563" 5.0" 18.563" 6.0"

Order Code WT-600-100 WT-750-100 WT-800-100 WT-1000-100 WT-1200-100 WT-1500-100 WT-2000-100 WT-2500-100 WT-3000-100 WT-4000-100 WT-5000-100 WT-6000-100

90

TRANSDUCERS / SENSORS

Amp 300 400 500 600 750 800 1000 1200

Type B — 50 mV Length Width 5.875" 1.75" 5.875" 2.00" 5.875" 2.00" 5.875" 2.00" 5.875" 2.25" 5.875" 2.375" 5.875" 2.50" 5.875" 3.00"


Instrument Transformer AC Split Core Current Transformers Model 613 – Window 0.8 x 1.95" Model 606 Weatherproof - Window 2.7 x 2.75" Model 608 Weatherproof – Window 2.6 x 6.25" 601

• 50-400 Hz • 0.6kV, BIL 10kV FW

• 50-400 Hz. • 0.6 kV, BIL 10 kV FW

L

606

Leads (613) #16 AWG, 24" Secondary Cable (606, 608) #16 AWG, 6ft

TRANSDUCERS / SENSORS

Leads (600, 601, 604) #16 AWG, 24"

ORDERING INFORMATION - MODEL 600 ORDERING INFORMATION – MODEL 600 ANSI Metering Order Current Class @ 60 Hz VA @ 1% Code Ratio B0.1 B0.2 B0.5 Class 600-401 400:5 2.4 4.8 1.5 600-501 500:5 2.4 4.8 2.0 600-601 600:5 2.4 2.4 2.5 600-801 800:5 1.2 1.2 2.4 5.0 600-102 1000:5 1.2 1.2 2.4 7.5 600-122 1200:5 0.6 1.2 1.2 15.0 600-152 1500:5 0.6 0.6 1.2 20.0 600-162 1600:5 0.6 0.6 1.2 20.0 600-202 2000:5 0.6 0.6 0.6 30.0 ORDERING INFORMATION - MODEL 601 Order Code 601-401 601-501 601-601 601-801 601-102 601-122 601-152 601-162 601-202

Current Ratio 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5

ANSI Metering Class @ 60 Hz B0.1 B0.2 B0.5 4.8 – – 4.8 4.8 – 2.4 4.8 – 1.2 2.4 4.8 1.2 1.2 4.8 1.2 1.2 2.4 1.2 1.2 1.2 1.2 1.2 1.2 0.6 0.6 1.2

VA @ 1% Class 1.0 1.5 2.0 2.5 5.0 10.0 15.0 15.0 20.0

ORDERING INFORMATION - MODEL 604 Order Code 604-101 604-1250 604-151 604-1750 604-201 604-251 604-301 604-401 604-1000T

91

613

L

600

L

L

Model 600 – Window 2 x 5.5" Model 601 – Window 4.5 x 4.5" Model 604 – Window 1.42 x 1.53"

Current Ratio 100:5 125:5 150:5 175:5 200:5 250:5 300:5 400:5 100:0.1

Burden VA 1 1 2 2 2 2 2 2.5 –

Accuracy ±5% ±5% ±4% ±3% ±2% ±2% ±1.5% ±1.5% ±3%

ORDERING INFORMATION - MODEL 613 Order Code 613-101 613-1250 613-151 613-1750 613-201 613-251 613-301 613-401

Current Ratio 100:5 125:5 150:5 175:5 200:5 250:5 300:5 400:5

Burden VA 1 1.25 1.5 1.75 2.5 2.5 3 3

Accuracy 60Hz 5% 5% 5% 5% 4% 4% 2% 2%

ORDERING INFORMATION - MODEL 606 Order Code 606-201 606-251 606-301 606-351 606-401 606-501 606-601 606-751 606-801 606-102 606-122

Current Ratio 200:5 250:5 300:5 350:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5

Burden VA 2.5 3 3.5 4 5 6 8 10 12 15 20

Accuracy 60Hz 2% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%

ORDERING INFORMATION - MODEL 608 Order Code 608-501 608-601 608-801 608-102 608-122 608-152 608-162 606-202 608-252 608-302 608-322

Current Ratio 500:5 600:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 3000:5 3200:5

Burden VA 6 8 12 13 16 25 27 33 42 50 54

Accuracy 60Hz 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%


Weschler AC Voltage Transformers L

460

• Seven Opening Sizes • 1 or 5 Amp Secondaries • 0.333V or 1.0V Secondaries • Indoor or Outdoor Use Flexible split-core opens with a twisting motion. Silicone rubber encapsulation protects against moisture, dirt, oil and corona. Remains flexible from -45° to +200°C.

• 600V Insulation Level, 10kV BIL • Accuracy Class 0.6W, 1.2x at 60Hz • 150VA at 30°C, 100VA at 55°C • 60Hz

L

Turns Ratio 0.58:1 1:1 1.73:1 2:1 2.4:1 2.5:1 4:1 5:1 3.15:1 for 50 Hz

L

467

ORDERING INFORMATION

A – B – C

C

Model FC Split core CT FCL UL Listed (Indoor use only) File E186575 Ratio See chart for available sizes Inside Diameter (inches) 4, 6, 8, 11, 18, R, R411 (R= 2-3/4 x 6-5/8, R411= 4 x 11)

AVAILABLE SIZES

ORDERING INFORMATION Voltage Rating (line to line) 69.3:120 120:120 208:120 240:120 288:120 300:120 480:120 600:120 380:120

4% 3% 2% 1% 12 feet long with spade connectors, Black wire = X1, White wire = X2

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: FC-1000/5-8

B

• 600V Insulation Level, 10kV BIL • ±1% Accuracy Class up to 5VA Burden • 40VA at 30°C, 27VA at 55°C • 60Hz

0.6kV, BIL 10kV Full Wave 50-400Hz 1.25 at 30°C, 1.0 at 55°C

Turns Ratio 0.58:1 1:1 1.73:1 2:1 2.4:1 2.5:1 4:1 5:1 3.17:1 for 50 Hz

Ratio 200/5 250/5 300/5 400/5 500/5 600/5 800/5 1000/5 1200/5 1500/5 1600/5 2000/5 2400/5 2500/5 3000/5 3500/5 4000/5 5000/5 6000/5

4" X X X X X X X X X X X X – – – – – – –

6" – – X X X X X X X X X X X X X X X X X

8" – – – – – – – X X X X X X X X X X X X

11" – – – – – – – – – X X X X X X X X X X

18" – – – – – – – – – – – X X X X X X X X

R – – – X X X X X X X X X X X X X X X X

R411 – – – – – – – – – X X X X X X X X X X

Burden 2VA 2VA 2VA 2VA 3VA 5VA 5VA 5VA 5VA 15VA 15VA 25VA 30VA 35VA 45VA 45VA 45VA 45VA 45VA

92

TRANSDUCERS / SENSORS

Voltage Rating (line to line) 69.3:120 120:120 208:120 240:120 288:120 300:120 480:120 600:120 380:120

Insulation Level: Frequency: Thermal factor: Accuracy: 200:5 thru 300:5 400:5 thru 500:5 600:5 thru 800:5 1000:5 thru 6000:5 Leads:

A

Order Code 467-069 467-120 467-208 467-240 467-288 467-300 467-480 467-600 467-380

FC

SPECIFICATIONS

ORDERING INFORMATION Order Code 460-069 460-120 460-208 460-240 460-288 460-300 460-480 460-600 460-380

Flexcore Split Core CT


L

Weschler AC Current Transformers RBL Case Style

• Solid Core • 0.6kV Insulation Class, BIL 10kV Full Wave • 50-400 Hz • 8-32 Studs or 24" Leads

DRL Case Style

L

SHT Case Style

L

LSFT Case Style L

L RL Case Style

RT Case Style

Models 2SFT and 2SHT—Window Dia. 1.13" Model 2RL—Window Dia. 1.05" Model 2DRL—Window Dia. 1"

ORDERING INFORMATION

TRANSDUCERS / SENSORS

2SFT, 2SHT, 2RL, 2DRL

Catalog # 2**-500 2**-600 2**-750 2**-800 2**-101 2**-121 2**-1250 2**-151 2**-201 2**-251 2**-301 2**-401

Current Ratio 50:5 60:5 75:5 80:5 100:5 120:5 125:5 150:5 200:5 250:5 300:5 400:5

Model 2S, 2R Accuracy Burden @ 60 Hz VA@ 60 Hz ±3% 2.0 ±2% 2.0 ±2% 2.0 ±2% 2.0 ±1% 2.0 ±1% 2.5 ±1% 2.5 ±1% 4.0 ±1% 4.0 ±1% 6.0 ±1% 8.0 ±1% 10.0

Model 2DRL Accuracy Burden @ 60 Hz VA @ 60 Hz ±2% 1.5 ±1% 2.5 ±1% 3.5 ±1% 4.0 ±1% 5.0 ±1% 5.0 ±1% 5.0 ±1% 8.0 ±1% 10.0 ±1% 12.5 ±1% 15.0 ±1% 20.0

Model 5—Window Dia. 1.56"

Model 7—Window Dia. 2.50"

ORDERING INFORMATION Model 7SFT, 7SHT, 7RT, 7RBT, 7RL, 7RBL Current Accuracy Burden Catalog # Ratio at 60 Hz at 60 Hz 7**-101 100:5 ±2% 2.5 7**-151 150:5 ±1% 5.0 7**-201 200:5 ±1% 5.0 7**-251 250:5 ±1% 5.0 7**-301 300:5 ±1% 12.5 7**-401 400:5 ±1% 15.0 7**-501 500:5 ±1% 25.0 7**-601 600:5 ±1% 30.0 7**-751 750:5 ±1% 30.0 7**-801 800:5 ±1% 35.0 7**-102 1000:5 ±1% 30.0 7**-122 1200:5 ±1% 35.0 7**-152 1500:5 ±1% 40.0 7**-162 1600:5 ±1% 45.0

Model 76—Window Dia. 3.00"

ORDERING INFORMATION Model 5SFT, 5SHT, 5RT, 5RBT, 5RL, 5RBL Current Accuracy Catalog # Ratio @ 60 Hz 5**-500 50:5 ±2% 5**-750 75:5 ±2% 5**-101 100:5 ±2% 5**-151 150:5 ±1% 5**-201 200:5 ±1% 5**-251 250:5 ±1% 5**-301 300:5 ±1% 5**-401 400:5 ±1% 5**-501 500:5 ±1% 5**-601 600:5 ±1% 5**-751 750:5 ±1% 5**-801 800:5 ±1% 5**-102 1000:5 ±1% 5**-122 1200:5 ±1%

L

RBT Case Style

Burden VA @ 60 Hz 1.0 1.5 2.0 5.0 5.0 10.0 12.5 12.5 20.0 25.0 25.0 25.0 25.0 30.0

ORDERING INFORMATION Model 76SFT, 76SHT, 76RT, 76RBT, 76RL, 76RBL Current Accuracy Burden Catalog # Ratio at 60 Hz at 60 Hz 76**-201 200:5 ±1% 5.0 76**-251 250:5 ±1% 5.0 76**-301 300:5 ±1% 6.0 76**-401 400:5 ±1% 10.0 76**-501 500:5 ±1% 10.0 76**-601 600:5 ±1% 10.0 76**-751 750:5 ±1% 10.0 76**-801 800:5 ±1% 12.5 76**-102 1000:5 ±1% 10.0 76**-122 1200:5 ±1% 10.0 76**-152 1500:5 ±1% 12.5 76**-162 1600:5 ±1% 12.5 76**-202 2000:5 ±1% 15.0

NOTE: **Insert case style when ordering

See CT Application Note in Technical Reference Section.

93


Weschler AC Current Transformers ORDERING INFORMATION Model 3P3 — Window Dia. 0.97"

L

3P

Model 8 — Window Dia. 3.25"

ORDERING INFORMATION Model 8SHT, 8RL V.A. for ±1% Class

8**-201 8**-251 8**-301 8**-401 8**-501 8**-601 8**-751 8**-801 8**-102 8**-122 8**-152 8**-162 8**-202 8**-252 8**-302 8**-352 8**-402

200:5 5.0 250:5 7.5 300:5 15.0 400:5 25.0 500:5 35.0 600:5 50.0 750:5 50.0 800:5 60.0 1000:5 75.0 1200:5 75.0 1500:5 90.0 1600:5 100.0 2000:5 120.0 2500:5 50.0 3000:5 60.0 3200:5 70.0 4000:5 80.0

ANSI Metering Class @ 60 Hz B0.1 B0.2 B0.5 B0.9

B1.8

1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

— — — — — 2.4 1.2 1.2 1.2 0.6 0.6 0.6 0.3 — — — —

1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

— 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

— — 2.4 1.2 1.2 1.2 0.6 0.6 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3

Model 170 — Window Dia. 4.25"

ORDERING INFORMATION

Current Ratio 50:5 60:5 75:5 80:5 100:5 120:5 125:5 150:5 200:5 250:5 300:5

Accuracy @ 60 Hz ±3% ±2% ±2% ±2% ±1% ±1% ±1% ±1% ±1% ±1% ±1%

Burden VA@60Hz 2.0 2.0 2.0 2.0 2.0 2.5 2.5 4.0 5.0 7.5 10.0

ORDERING INFORMATION Model 3P4 — Window Dia. 1.44" Catalog # 3P4–500 3P4–101 3P4–151 3P4–201 3P4–251 3P4–301 3P4–401 3P4–501 3P4–601 3P4–751 3P4–801 3P4–102

Current Ratio 50:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5

B0.1 4.8 1.2 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3

ANSI Metering Class @ 60 Hz B0.2 B0.5 B0.9 B1.8 – – – – 2.4 – – – 1.2 2.4 – – 0.6 1.2 2.4 – 0.6 1.2 2.4 2.4 0.3 0.6 1.2 2.4 0.3 0.6 1.2 1.2 0.3 0.6 0.6 1.2 0.3 0.6 0.6 1.2 0.3 0.6 0.6 0.6 0.3 0.6 0.6 0.6 0.3 0.3 0.6 0.6

TRANSDUCERS / SENSORS

Catalog #

Current Ratio Amperes

Catalog # 3P3–500 3P3–600 3P3–750 3P3–800 3P3–101 3P3–121 3P3–1250 3P3–151 3P3–201 3P3–251 3P3–301

Model 170SHT, 170RL

Catalog #

170**-201 170**-251 170**-301 170**-401 170**-501 170**-601 170**-751 170**-801 170**-102 170**-122 170**-152 170**-162 170**-202 170**-252 170**-302 170**-352 170**-402

Current V.A. for Ratio ±1% Amperes Class

ANSI Metering Class @ 60 Hz B0.1 B0.2 B0.5 B0.9

200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 3000:5 3200:5 4000:5

1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

5.0 5.0 12.5 25.0 25.0 25.0 40.0 50.0 75.0 100.0 80.0 90.0 105.0 130.0 165.0 190.0 215.0

1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

— — 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

— — 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.6 0.6 0.3 0.3 0.3 0.3 0.3

NOTE: **Insert case style when ordering

Model 180/181 — Window Dia. 2.5" B1.8

— — — 2.4 2.4 1.2 0.6 0.6 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3

ORDERING INFORMATION Model 180RL, 180SHT, 181RL, 181SHT

Catalog #

Current V.A. for Ratio ±1% Amperes Class

ANSI Metering Class @ 60 Hz B0.1 B0.2 B0.5 B0.9 B1.8

180**-101 180**-151 180**-201 180**-251 180**-301 180**-401 180**-501 180**-601 180**-751 180**-801 180**-102 180**-122 180**-152 180**-162

100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 1600:5

1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

2.5 5.0 12.5 12.5 25.0 50.0 50.0 50.0 50.0 75.0 100.0 125.0 160.0 175.0

2.4 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

— — 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

— — — — 1.2 0.6 0.6 0.6 0.3 0.3 0.6 0.6 0.3 0.3

— — — — 2.4 1.2 1.29 0.6 0.6 0.3 0.6 0.6 0.3 0.3

94


Instrument Transformer AC Current Transducers

NK Technologies Ground Fault Sensor

• Large Window Area

• 0.5% FS accuracy

• 4-20mA DC Output

• 120VAC or 24VDC Power

The PCL is a 4 terminal device with separate connections for power and load. The PCM is a two terminal device. 24V is applied between the + terminal and ground. The output load may be inserted in either the – line for negative ground systems or the + line for positive ground systems.

TRANSDUCERS / SENSORS

Output Load: Size (LxWxH, inches) PCL-5 thru 75 PCL-100 & up PCM-5 thru 20 PCM-30 & up

SPECIFICATIONS Setpoint:

Average responding, RMS calibrated 0-120% of rated current (typical) 50/60Hz -30 to 60°C 600V, 10kV BIL full wave 30mA DC 1% max peak PCL 120VAC ±10% PCM 24VDC ±10% PCL <1000 ohms PCM <600 ohms Window dia 0.94" 2.13" 0.93" 1.25"

2.7 x 2.4 x 4.5 4.5 x 4.7 x 4.9 2.7 x 2.4 x 2.75 4.5 x 4.7 x 4.9

ORDERING INFORMATION Model PCL-5 PCL-20 PCL-75 PCL-100 PCL-150 PCL-200 PCL-300 PCL-400 PCL-600 PCM-5 PCM-10 PCM-20 PCM-30 PCM-50 PCM-75 PCM-100 PCM-150 PCM-200 PCM-300 *Switch selectable

Rated Current 5A 10A, 15A, 20A* 25A, 50A, 75A* 100A 150A 200A 300A 400A 600A 5A 10A 20A 30A 50A 75A 100A 150A 200A 300A

• Fixed or selectable setpoint • Solid-state or relay output • Green LED Power-On indication Detects ground fault (earth leakage) conditions by monitoring all currentcarrying conductors in a grounded single or three phase system.

SPECIFICATIONS Output Signal: Linear Range: Frequency: Operating Temperature: Insulation Level: Maximum Output: Output Ripple: Supply Voltage:

Connections #8 screws #8 studs

#10 screws

#8 studs

AG1, AG2: factory calibrated AG3: field jumper selected Solid-state Output: Isolated dry contact AC Switch: 1A @ 240VAC DC Switch: 0.15A @ 30VAC Leakage <10 micro Amps (N.O.), <2.5mA (N.C.) Mechanical Output: Single pole relay Auto Reset: SPDT, 1A @ 125VAC, 2A @ 30VDC Latching: SPST, 1A @ 125VAC, 2A @ 30VDC Response Time: 200ms @ 5% above trip point 60ms @ 50% above trip point 15ms @ 500% above trip point Isolation: 5kVAC (tested) Frequency: 50–400 Hz (monitored circuit) Power Supply: 66-132VAC 19.2-28.8VAC/DC Loading: 2VA max. Case: UL94 V0 Flammability Rated Environment: -4 to 122°F (-20 to 50°C), < 95% RH, non-condensing Size: 3.9"W x 3.0"H x 1.5"D (99x76x38mm) Listings: UL 1053, Class 1 Recognized, CE

ORDERING INFORMATION To Order Insert Code for Each Letter to Select Catalog Number Example: AG1-NOAC-120-FS-005 AG A – B – C – D – E A Se tpoint 1 5–100mA factory set 2* 80–950mA factory set 3 5/10/30mA jumper set (TR3 only) B Output Type NOAC Normally Open solid state, 1A @ 240VAC NCAC Normally Closed solid state, 1A @ 240VAC NODC Normally Open solid state, 0.15A @ 30VDC NCDC Normally Closed solid state, 0.15A @ 30VDC NCR1 Normally Closed SPST Relay (requires LA option) NOR1 Normally Open SPST Relay (requires LA option) SDT1 SPDT Relay (Form C) with autoreset (requires DEN or ENE option) C Power Suppl y 120 120VAC 24U* 24VAC/VDC D Op tions FS Normally Energized (solid state output only) NF Normally De-energized (solid state output only) ENE Normally Energized, auto-reset (SDT1 output only) DEN Normally De-energized, autoreset (SDT1 output only) LA Latching (NOR1 and NCR1) E Se tpoint TR3 Tri-set (5/10/30mA) nnn Factory set trip point in mA

*Not UL recognized.

95

NEW


Weschler Transducers AC & DC Transducers—Metal Case

L

• Accuracy: ±0.2% or 0.5% • Wide Variety of Input and Output Options • Rugged Metal Can Construction • 5 kV Transient Protection • Sizes: Can size 1: 3.976" L x 2.012" W x 4.096" H Can size 2: 5.236" L x 3.769" W x 4.717" H

CLD001J

AC CURRENT TRANSDUCER Output 0–1 mADC 4 mA–20 mADC 0–1 mADC 4 mA–20 mADC 0–1 mADC 4 mA–20 mADC 0–1 mADC 0–1 mADC 4 mA–20 mADC

Transducer Type Single (average sensing) Single (average sensing) Single (average sensing) Single (average sensing) Single (average sensing) Single (average sensing) 3 Inputs (average sensing) 3 Inputs (average sensing) Single (TRMS sensing) Single (TRMS sensing) Single (TRMS sensing) Single (TRMS sensing)

Input 0–150 VAC 0–300 VAC 0–600 VAC 0–150 VAC 0–300 VAC 0–600 VAC 0–150 VAC 0–300 VAC 0–150 VAC 0–300 VAC 0–150 VAC 0–300 VAC

Output 0–1 mADC 0–1 mADC 0–1 mADC 4 mA–20 mADC 4 mA–20 mADC 4 mA–20 mADC 0–1 mADC 0–1 mADC 0–1 mADC 0–1 mADC 4 mA–20 mADC 4 mA–20 mADC

Frequency 45-55 Hz 45-65 Hz 55-65 Hz 375-425 Hz 45-55 Hz 45-65 Hz 55-65 Hz 375-425 Hz

Input 120V 120V 120V 120V 120V 120V 120V 120V

Aux. Power None 120 VAC 120 VAC 120 VAC None 120 VAC None 120 VAC 120 VAC

Can Size 1 2 2 2 1 2 2 2 2

Part # ±0.5% CTA100JA CTD100JA CTA100JT CTD100JT CTA500JA CTD500JA CTA503JA CTA500JT CTD500JT

Part # ±0.2% CTA100ZA CTD100ZA CTA100ZT CTD100ZT CTA500ZA CTD500ZA CTA503ZA CTA500ZT CTD500ZT

Specifications on PAGE 98.

TRANSDUCERS / SENSORS

Input 0–1 AAC 0–1 AAC 0–1 AAC 0–1 AAC 0–5 AAC 0–5 AAC 0–5 AAC 0–5 AAC 0–5 AAC

L

Transducer Type Single (average sensing) Single (average sensing) Single (TRMS sensing) Single (TRMS sensing) Single (average sensing) Single (average sensing) Triple (average sensing) Single (TRMS sensing) Single (TRMS sensing)

AC VOLTAGE TRANSDUCER Can Size 1 1 1 2 2 2 2 2 2 2 2 2

Part # ±0.5% ETA150JA ETA300JA ETA600JA ETD150JA ETD300JA ETD600JA ETA153JA ETA303JA ETA150JT ETA300JT ETD150JT ETD300JT

Part # ±0.2% ETA150ZA ETA300ZA ETA600ZA ETD150ZA ETD300ZA ETD600ZA ETA153ZA ETA303ZA ETA150ZT ETA300ZT ETD150ZT ETD300ZT

L

Aux. Power None None None 120 VAC 120 VAC 120 VAC None None 120 VAC 120 VAC 120 VAC 120 VAC

Specifications on PAGE 98.

AC FREQUENCY TRANSDUCER—CAN SIZE “2” Part # ±1.0% FQA050J FQA055J FQA060J FQA400J FQD050J FQD055J FQD060J FQD400J

Part # ±0.1% FQA050Z FQA055Z FQA060Z FQA400Z FQD050Z* FQD055Z* FQD060Z* FQD400Z*

L

Output 0-1 mA 0-1 mA 0-1 mA 0-1 mA 4-12-20 mADC 4-12-20 mADC 4-12-20 mADC 4-12-20 mADC

Specifications on PAGE 98.

*Accuracy is 0.2%

96


Weschler Transducers AC WATT TRANSDUCER—CAN SIZE "2" Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire

No. of Elements 1 element 2 element 21/2 element 3 element 1 element 2 element 21/2 element 3 element

Rating 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A

Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire

No. of Elements 1 element 2 element 21/2 element 3 element 1 element 2 element 21/2 element 3 element

Rating 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A

Output 0–1 mADC 0–1 mADC 0–1 mADC 0–1 mADC 4 mA–20 mADC 4 mA–20 mADC 4 mA–20 mADC 4 mA–20 mADC

Aux. Power None None None None None None None None

Part # ±0.5% WTB010J WTB020J WTB025J WTB030J WTD010J WTD020J WTD025J WTD030J

Part # ±0.2% WTB010Z WTB020Z WTB025Z WTB030Z WTD010Z WTD020Z WTD025Z WTD030Z

Part # ±0.5% VTB010J VTB020J VTB025J VTB030J VTD010J VTD020J VTD025J VTD030J

Part # ±0.2% VTB010Z VTB020Z VTB025Z VTB030Z VTD010Z VTD020Z VTD025Z VTD030Z

AC VAR TRANSDUCER—CAN SIZE "2" Output ±1 mADC ±1 mADC ±1 mADC ±1 mADC 4-12–20 mADC 4-12–20 mADC 4-12–20 mADC 4-12–20 mADC

Aux. Power None None None None None None None None

TRANSDUCERS / SENSORS

AC WATT/VAR TRANSDUCER—CAN SIZE "2" Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire

No. of Elements 1 element 2 element 21/2 element 3 element 1 element 2 element 21/2 element 3 element

Rating 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A

Output ±1 mADC x 2 ±1 mADC x 2 ±1 mADC x 2 ±1 mADC x 2 W: 4–20mA, VAR: 4-12–20 mA W: 4–20mA, VAR: 4-12–20 mA W: 4–20mA, VAR: 4-12–20 mA W: 4–20mA, VAR: 4-12–20 mA

Part # ±0.5% WVB010J WVB020J WVB025J WVB030J WVD010J WVD020J WVD025J WVD030J

Part # ±0.2% WVB010Z WVB020Z WVB025Z WVB030Z WVD010Z WVD020Z WVD025Z WVD030Z

Part # STD TC PFB010J PFB020J PFB030J PFF010J PFF020J PFF030J

Part # Low TC PFB010Z PFB020Z PFB030Z PFF010Z PFF020Z PFF030Z

Part # ±2° PAB010J PAB020J PAB030J PAF010J PAF020J PAF030J

Part # ±1° PAB010Z PAB020Z PAB030Z PAF010Z PAF020Z PAF030Z

AC POWER FACTOR—CAN SIZE "2" Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire

Lag—Lead -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5

Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire

Phase Angle 60°–0–60° 60°–0–60° 60°–0–60° 60°–0–60° 60°–0–60° 60°–0–60°

Output 1–0–1 mADC 1–0–1 mADC 1–0–1 mADC 4 –12–20 mADC 4 –12–20 mADC 4 –12–20 mADC

AC PHASE ANGLE—CAN SIZE "2"

NOTE: Also available in plastic foot-mounted or DIN rail. For ranges not listed, contact Weschler.

97

Output 1–0–1 mADC 1–0–1 mADC 1–0–1 mADC 4–12–20 mADC 4–12–20 mADC 4–12–20 mADC


Weschler Transducers POWER FACTOR TRANSDUCERS

SPECIFICATIONS - ALL AC MODELS Output Response Time Output Ripple Isolation

External Span Adjustment Surge Withstand Insulation Resistance Operating Temperature

0-1 or ±1mADC into 10kΩ max., 10VDC compliance 4-20mADC into 750Ω max., 15VDC compliance <400ms (0-99% of output) 0.5% of span, peak-to-peak max 2500VAC input to output, power & case 2000VAC aux. power to output & case 500VAC output to case Zero: ±1% min; Span: ±2% min IEEE472/ANSI C37.90.1-1989, JIS C111 (5kV, 1.2 x 50µs) >10MΩ@500VDC input/output/power/case -20°C to 60°C; 0-90% RH non-condensing

Specifications same as Combined Watt/VAR Models except: Accuracy ±0.01 power factor Temperature Drift ±500ppm/°C of span, suffix J models ±150ppm/°C of span, suffix Z models Low Current Detect <4% Influences (% of span) <1% for voltage, <2% for current Options for PF Models 1 AAC Current Rated 120VAC, 240VAC, 24VDC or 48VDC Auxiliary Power

AC PHASE ANGLE TRANSDUCERS

AC CURRENT & VOLTAGE TRANSDUCERS Current Models Input Burden Overrange

<0.2VA 200% of rated input continuous; 1000% of rated input for 5 sec

Voltage Models Input Burden

150VAC: <0.8VA; 300 VAC: <1.6VA (TRMS) 150VAC: <1.8VA; 300 VAC: <3.6VA (Avg. Sensing) Overrange 120% of rated input continuous Temperature Drift ±250ppm/°C of span, 0.5% models ±140ppm/°C of span, 0.2% models Options (specify when ordering) 50Hz, 50/60Hz or 400Hz operation (60Hz standard) 230VAC, 24VDC* or 48VDC* Auxiliary Power (*average sensing models only)

Input Burden Voltage Input Range

Voltage Overrange Current Input Range Current Overrange Output Calibration Temperature Drift Influences (% of span)

Voltage: <0.5VA per element @120V Current: <0.2VA per element 100-135VAC, input powered 0.5% models 85-135VAC, input powered 0.2% models 0-120% of rated input, auxiliary powered models 150% of rated input continuous (aux. powered only) 10-200% of rated input with accuracy 200% continuous, 1000% for 5 seconds 120VAC/1A = 0-100 watts/element 120VAC/5A = 0-500 watts/element ±250ppm/°C of span, 0.5% models ±80ppm/°C of span, 0.2% models <0.5% for PF, phase interaction or current imbalance

COMBINED AC WATT/VAR TRANSDUCERS Input Burden Voltage Input Range

Voltage Overrange Current Input Range Current Overrange Temperature Drift Influences (% of span)

Voltage: <0.5VA per element Current: <0.2VA per element 100-135VAC, input powered 0.5% models 85-135VAC, input powered 0.2% models 0-120% of rated input, auxiliary powered models 150% of rated input continuous (aux. powered only) 10-200% of rated input with accuracy 200% continuous, 1000% for 5 seconds ±250ppm/°C of span, 0.5% models ±80ppm/°C of span, 0.2% models <0.5% for PF, phase interaction or current imbalance

Options for Watt, VAR & Watt/VAR Models 50Hz or 400Hz operation (60Hz standard) 1AAC Current Rated 240VAC Voltage Rated 480 VAC Voltage Rated (not available on 0.2% units) 120VAC, 240VAC, 24VDC or 48VDC Auxiliary Power Special Calibration to Customer PT & CT

Options for Phase Angle Models 50Hz or 400Hz operation (60Hz standard) 1AAC Current Rated 120VAC, 240VAC, 24VDC or 48VDC Auxiliary Power Full Scale = Lagging Phase Angle ±90° Phase Angle

FREQUENCY TRANSDUCER Input Burden Voltage Input Range

TRANSDUCERS / SENSORS

AC WATT & VAR TRANSDUCERS

Specifications same as Combined Watt/VAR Models except: Temperature Drift ±500ppm/°C of span, suffix J models ±80ppm/°C of span, suffix Z models Influences <0.5° for voltage, <1° for current

<0.1VA @120V 100-135VAC, input powered models ±20% of rated voltage, aux. powered models ±250ppm/°C of span, suffix J models ±50ppm/°C of span, suffix Z models Fundamental through 9th harmonic

Temperature Drift Harmonics

Options for Frequency Models 240 Volt Input 24VDC or 48VDC Aux. Power (0.2% models only) 1-0-1 mADC Output

DC TO DC ISOLATION TRANSDUCERS Input Burden Output Compliance Accuracy (<10% of range) Response Time Calibration Adjustments Temperature Range Isolation

Surge Withstand Auxiliary Power

<1 mA 10VDC ±0.5% of FS 500ms (0-99%) ±5% (zero & FS) 0-40°C, 20-90% RH non-condensing 2600VAC input to output, power & case 1000VAC aux power to output & case 1000VAC output to case IEEE472/ANSI C37.90.1-1989 SWC 120VAC ±10%, 2VA

DC TO DC ORDERING INFO Input 0-1mADC 0-1mADC 0-1mADC 0-50mVDC 0-50mVDC 0-50mVDC

Output 4-20mADC 0-1mADC 0-10VDC 4-20mADC 0-1mADC 0-10VDC

Aux. Power 120VAC 120VAC 120VAC 120VAC 120VAC 120VAC

Case Size 2 2 2 2 2 2

Part # CLD001J CLD002J CLD003J CLD101J CLD102J CLD103J

98


NK Technologies AC Current Transducers AT and ATP current transducers combine a current transformer and signal conditioner in a single package. These transducers offer jumper selected current input ranges with proportional industry standard 4-20 mA, 0-5 VDC and 0-10 VDC outputs. The AT and ATP series are designed for application on “linear” or sinusoidal AC loads. Available in a split core or two types of solid core cases.

ATR and ATPR transducers combine a current transformer and True RMS signal conditioner in a single package. The ATR and ATPR series provide True RMS outputs on distorted waveforms found on VFD and SCR outputs or on linear loads in “noisy” power environments. Available in a solid or split core case.

AT & ATP SPECIFICATIONS

ATR & ATPR SPECIFICATIONS

-005 Models -010 Models -420 Models 0–5 VDC 0–10 VDC 4–20 mA 10 VDC 15 VDC 40 mA 1.0% FS 1.0% FS 0.5% FS 50–60 Hz 50–60 Hz 20–100 Hz Self or External Self or External Loop or External UL Listed to 1270 VAC, Tested to 5 kV -FF Case: 0.55" (14 mm) Diameter -FT Case: 0.75" (19 mm) Diameter -SP Case: 0.85" (21.5 mm) Sq. UL 94V-0 Flammability Rated -4 to 122˚F (-20 to 50˚C), 0–95% RH, Non-Condensing UL 508 Industrial Control Equipment (USA and Canada), CE

Output Signal: Output Limit: Accuracy: Frequency Range: Power Supply: Isolation Voltage: Sensing Aperture:

L

Case: Environmental: Listings:

TRANSDUCERS / SENSORS

FL Style Case

Output Signal:

4–20 mA, Loop-Powered, True RMS

Output Limit:

23 mA

Accuracy:

0.8% FS (1.0% on ATR3 & 4)

Frequency Range: 10–400 Hz Power Supply:

24VDC Nom., 40 VDC Max., 120 VAC

Isolation Voltage:

UL Listed to 1270 VAC, Tested to 5 kV (600 VAC on ATR3 & 4)

Sensing Aperture: -FT Models: 0.75" (19 mm) Dia. -FL Models: 3.0" (76 mm) Dia. -SP Models: 0.85" (21.5 mm) Sq. Case:

UL 94V-0 Flammability Rated

Environmental:

-4 to 122˚F (-20 to 50˚C), 0–95% RH, Non-Condensing

FT Case Style

Listings:

UL 508 Industrial Control Equipment (USA and Canada)

L

Loading (All Models)

L

SP Case Style

FF Case Style

Loop Power:

RL <500Ω

External Power:

RL >50kΩ Accuracy for RL >1ΜΩ,

Self Powered:

add 1.3% for RL = 100 kΩ

L ORDERING INFORMATION

A B

C

D E

99

Model AT Average sensing, loop or self-powered Input Ranges 0 0–2/5A 1 0–10/20/50A 2 0–100/150/200A 3 0–375/500/750A 4 0–1000/1333/2000A Output 420 4–20mA 005 0–5 VDC (0,1,2 only) 010 0–10 VDC (0,1,2 only) Power 24L 24 VDC Loop Powered (4–20mA only) 000 Self powered (DC output only) Case FF Fixed core, front terminals (0,1,2 only) FT Fixed core, top terminals (0,1,2 only) SP Split core FL Fixed core (3 & 4 only)

A B

C

D E

Model ATP Average sensing, ext. powered ATPR True RMS sensing, ext. powered Input Ranges 0 0–2/5A (ATP only) 1 0–10/20/50A (ATP only) 2 0–100/150/200A (ATP only) 3 0–375/500/750A 4 0–1000/2000A Output 420 4–20mA 005 0–5 VDC 010 0–10 VDC Power 24U 24V AC/DC, isolated output 120 120VAC Case FF Fixed core, front terminals (0,1,2 only) FL Fixed core (3 & 4 only) SP Split core (0,1,2 only)

A B C D E

Model ATR Input 3 4 Output 420 Power 24L Case FL

TRMS sensing, loop powered 0–375/500/750A 0–1000/1333/2000 4–20mA 24VDC, loop powered Fixed core


Crompton AC Current and Voltage Transducers

• CE Compliant (CE Marked) • Flexible Design with up to Three Transducers in One Housing • UL Approved • Enclosure to IEC529 (IP50) • Flame Retardant • 35 mm DIN Rail Mount or Key Hole Slots

AC Current, Voltage, Frequency and DC • Average Sensing and True RMS • Self Powered and Auxiliary • Current Measuring to 0.5% Accuracy • Isolated Input and Output

L

253

FREQUENCY Frequency 45–55 Hz 55–65 Hz 45–65 Hz 360–440 Hz

Output 0–1 mADC 0–1 mADC 0–1 mADC 0–1 mADC

Catalog Number 253-THZU-PQFA-AG 253-THZU-PQFA-AN 253-THZU-PQFA-AJ 253-THZU-PQFA-BI

TRANSDUCERS / SENSORS

Input 120 VAC 120 VAC 120 VAC 120 VAC

AC CURRENT Input AC Current—Average Sensing, Single-Phase 5A AC/60 Hz 5A AC/60 Hz AC Current—Average Sensing, 3-Phase, 3 DC Outputs 5A AC/60 Hz 5A AC/60 Hz AC Current—True RMS Sensing, Single-Phase 5A AC/60 Hz AC Current—True RMS Sensing, 3-Phase, 3 DC Outputs 5A AC/60 Hz AC Current—Bi-Directional 5A AC/60 Hz

Auxiliary Power Self 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC Self (120 VAC)

Output 0–1 mADC 4–20 mADC 0–1 mADC 4–20 mADC 0–1 mADC 0–1 mADC ±1 mADC

Catalog Number 253-TAAU-LSFA-C6 253-TALU-LSHG-C6-DG 256-TASU-LSFA-C6-DG 256-TALU-LSHG-C6-DG 253-TARU-LSFA-C6-DG 256-TARU-LSFA-C6-DG 256-TABU-LSM1-C6-PQ-T3

AC VOLTAGE Input Auxiliary Power Output AC Voltage—Average Sensing, Single-Phase 120 VAC/60 Hz Self 0–1 mADC 120 VAC/60 Hz 120 VAC 4–20 mADC AC Voltage—True RMS Sensing, Single-Phase 120 VAC/60 Hz 120 VAC 0–1 mADC AC Voltage—True RMS Sensing, 3-Phase, 3 DC Outputs 120 VAC/60 Hz 120 VAC 0–1 mADC Input System Output AC Voltage—Average Sensing, 3-Phase, 3 DC Outputs 120 VAC/60 Hz 3-Phase, 3-Wire 4–20 mADC 120 VAC/60 Hz 3-Phase, 4-Wire 0–1 mADC Input Auxiliary Power Output AC Voltage—Suppressed Zero AC, Expanded Scale 108–132 VAC Self 0–1 mADC

Catalog Number 253-TVAU-PQFA-C6 253-TVLU-PQHG-C6-DG 253-TVRU-PQFA-C6-DG 256-TVRU-PQFA-C6-DG Catalog Number 256-TVLU-PQHG-C6-DG 256-TVSU-PQFA-C6-DG Catalog Number 253-TVZU-A9FA-C6

100


Crompton Transducers AC Power Transducers • Wide Range of Transducers to Measure All Forms of Power • Available in Single-Phase, 3-Phase 3- or 4-Wire • Self Powered Units Permit Voltage Variations Up to 20% of Nominal Input • Measures both Import and Export Power • Accuracy Class 0.5

DC/DC & TEMPERATURE Input

Auxiliary Power

Output

Catalog Number

DC Current

120 VAC

0–1 mADC

256-TTAU-**FA-DG

DC Millivolts

120 VAC

0–1 mADC

256-TTMU-**FA-DG

DC Voltage

120 VAC

0–1 mADC

256-TTVU-**FA-DG

K Thermocouple

120 VAC

0–1 mADC

256-TTNU-KTFA-DG

T Thermocouple

120 VAC

0–1 mADC

256-TTCU-TTFA-DG

J Thermocouple

120 VAC

0–1 mADC

256-TTFU-JTFA-DG

AC POWER TRANSDUCERS / SENSORS

System

Input

Type

Output

Catalog Number

1 Ph, 2 Wire

120V/5A

1 Element

0-1 mADC

256-TWKU-QQFA-C6-**

1 Ph, 3 Wire

240V/10A

1 Element

0-1 mADC

256-TWKU-Q8FA-C6-**

3 Ph, 3 Wire

120V/5A

2 Element

0-1 mADC

256-TWMU-QQFA-C6-**

3 Ph, 4 Wire

120V/5A

2 /2 Element

0-1 mADC

256-TWNU-QQFA-C6-**

AC Watts (Active Power)

1

** Specify Range AC VARS (Reactive Power) 1 Ph, 2 Wire

120V/5A

1 Element

0-1 mADC

256-TXKU-QQFA-C6-**

1 Ph, 3 Wire

240V/10A

1 Element

0-1 mADC

256-TXKU-Q8FA-C6-**

3 Ph, 3 Wire

120V/5A

2 Element

0-1 mADC

256-TXMU-QQFA-C6-**

3 Ph, 4 Wire

120V/5A

2 /2 Element

0-1 mADC

256-TXNU-QQFA-C6-**

1 Element

0-1 mADC

256-TYKU-QQFA-C6-**

1

** Specify Range AC VA (Apparent Power) 1 Ph, 3 Wire

120V/10A

3 Ph, 3 Wire

120V/5A

2 Element

0-1 mADC

256-TYMU-QQFA-C6-**

3 Ph, 4 Wire

120V/5A

2 1/2 Element

0-1 mADC

256-TYNU-QQFA-C6-**

** Specify Range Power Factor (Suits Analog Meters) - Accuracy Class 0.2

101

1 Ph, 2 Wire

120V/5A

0-1-0

1-0-1 mADC

256-XFSU-QQFA-C3-Z1-DG

1 Ph, 2 Wire

120V/5A

1-0-1-0-1

1-0-1 mADC

256-XFAU-QQFA-C3-E4-DG

3 Ph, 3 Wire

120V/5A

0-1-0

1-0-1 mADC

256-XFWV-QQFA-C3-Z1-DG

3 Ph, 3 Wire

120V/5A

1-0-1-0-1

1-0-1 mADC

256-XFGU-QQFA-C3-E4-DG

3 Ph, 4 Wire

120V/5A

0-1-0

1-0-1 mADC

256-XFVU-QQFA-C3-Z1-DG

3 Ph, 4 Wire

120V/5A

1-0-1-0-1

1-0-1 mADC

256-XFDU-QQFA-C3-E4-DG


Crompton Power & Energy Transducer Systems L

• Replaces multiple single function transducers • Measures up to 50 electrical parameters • True 3 and 4 wire measurement • Power, energy & power quality data • Pulsed, analogue and digital outputs • Programmable VT and CT ratios • Local or remote configuration & monitoring • DIN rail or base mounted styles

1560

Up to 50 electrical and power quality parameters can be measured and communicated into building management systems or viewed through the PC configuration software.

ORDERING INFORMATION To Order: Insert Code for Each Letter to Select Catalog Number.

These transducers can be programmed using the configuration software or the optional Integra display unit. The display unit can be permanently mounted near the transducer, or connected when configuration or status information is required.

Example INT-1563-M-5-M-013-1 INT- A – B – C – D – E A

SPECIFICATIONS Volt age 120% nominal 2x for 1 sec. < 0.2 VA up to 400kV ** 9999:5A **

Cur rent 120% nominal 20x for 1 sec. < 0.6 VA B

Two wire half duplex 2400, 4800, 9600, 19200 Clean contact SPNO, 100V DC 0.5A max 60, 100 or 200 milliseconds 85-287 V AC / 85-312 V DC Absolute,45-66 Hz 10.2-60 V DC Absolute 6VA 80-120% of nominal (functional 5-120%) 5-120% of nominal 45-66Hz 0.8 capacitive to 0.8 inductive Up to 31st harmonic 0% - 40% 7 digit resolution ±0.17% of range 0.15% of mid frequency ±0.2% of range 1% of unity ±0.5% of range ±0.2% of range ±1% ±0.95% of range KWh 1% IEC1036 2% ±0.2% -20 to +60°C, <90% RH Polycarbonate 5.5"H x 3.72"W x 3.72"D (140 x 95 x 95mm) 5.2"H x 3.74"W x 5.24"D (132 x 95 x 134mm) 4.31"H x 4.31"W x 2.9"D(110 x 110 x 74mm) 4.06" (103mm) diameter, 4 studs

C D

E

F

Model 1561 single phase 5A CT input, DIN Rail 1562 single phase 3 wire 5A CT input, DIN Rail 1563 3 phase 3 wire 5A CT input, DIN Rail 1564 3 phase 4 wire 5A CT input, DIN Rail 1581 single phase 5A CT input, Base mount 1582 single phase 3 wire 5A CT input, Base mount 1583 3 phase 3 wire 5A CT input, Base mount 1584 3 phase 4 wire 5A CT input, Base mount Input Volt age L 57.7 – 139V L-N (1561 & 1581) 114 - 278 V L-L, 57.7 – 139V L-N (1562 & 1582) 100 – 240 V L-L, 57.7 – 139V L-N (1563,4 & 1583,4) M 140 – 277 V L-N (1561 & 1581) 279 – 480 V L-L, 140 – 240V L-N (1562 & 1582) 241 – 480 V L-L, 140 – 277V L-N (1563,4 & 1583,4) Input Cur rent 5 5A (CT secondary) Auxiliar y Suppl y L 12 – 48V DC M 100 – 250V AC/DC Communications Op tions 010 1 Modbus 012 1 Modbus, 2 analog 013 1 Modbus, 3 analog 014 1 Modbus, 4 analog 110 1 pulse/relay, 1 Modbus 112 1 pulse/relay, 1 Modbus, 2 analog 113 1 pulse/relay, 1 Modbus, 3 analog 114 1 pulse/relay, 1 Modbus, 4 analog 210 2 pulse/relay, 1 Modbus 212 2 pulse/relay, 1 Modbus, 2 analog 410 4 pulse/relay, 1 Modbus 412 4 pulse/relay, 1 Modbus, 2 analog 610 6 pulse/relay, 1 Modbus 612 6 pulse/relay, 1 Modbus, 2 analog Analog Output Range 0 No output 1 0-20 mA, 10V compliance, user configurable as 4-20 mA (3 channels max) 2 0-1 mA, 10V compliance 3 -1/0/+1 mA, 10V compliance 4 0-5 mA, 10V compliance 6 0-10 mA, 10V compliance

** 360MW max at 120% of relevant input

102

TRANSDUCERS / SENSORS

Input Max Continuous: Max Short Duration: Burden: PT Ratio (primary): CT Primary: Outputs RS485: Baud Rate: Pulsed: Pulse Duration: Auxiliar y Suppl y AC/DC: DC: Supply Burden: Measur ing Ranges Voltage: Current: Frequency: Power Factor: THD: Energy: Accur acy Voltage, Current: Frequency: Power: Power Factor: Reactive Power (VAr): Apparent Power (VA): THD: Neutral Current: Energy: KVArh: Analog Output: Operating Temperature: Enclosure DIN Transducer: Base Mount Transducer: Display: Panel Cut Out (Display):

– F


Veris Split Core KW Transducers ORDERING INFORMATION

®

• Meter electronics and current transformers in a single package • Split-core system eliminates the need to remove conductors • Automatic compensation for CT orientation • Continuous TRMS Readings

TRANSDUCERS / SENSORS

SPECIFICATIONS Input Primary Voltage Number of Phases Monitored Internal Isolation Insulation Class Temperature Range Humidity Range Accuracy Output Supply Power (current loop) CT Opening

208-480VAC rms, 50/60Hz One or Three 2000VAC rms 600VAC rms 0 to 60°C, 50°C for 2400A 0 to 95% non-condensing ±1% 4-20mA 9-30VDC; 30mA max. Small 1.5" x 1.25" (38x32mm) Medium 2.9" x 2.45" (73x62mm) Large 5.5" x 2.45" (140 x 62mm) Models with Modbus and Pulse Outputs also available.

Single CT Models for Use w/ Balanced 3Ø Loads or 1Ø 2 Wire Installations Max. Model Voltage Amps CT Size VE/H8041-0100-2 208/240 100 small VE/H8041-0300-2 208/240 300 small VE/H8041-0400-3 208/240 400 medium VE/H8041-0800-3 208/240 800 medium VE/H8041-0800-4 208/240 800 large VE/H8041-1600-4 208/240 1600 large VE/H8041-2400-4 208/240 2400 large VE/H8042-0100-2 480 100 small VE/H8042-0300-2 480 300 small VE/H8042-0400-3 480 400 medium VE/H8042-0800-3 480 800 medium VE/H8042-0800-4 480 800 large VE/H8042-1600-4 480 1600 large VE/H8042-2400-4 480 2400 large Three CT Models for Use with Any 3Ø Load or 1Ø 3 Wire Installations Max. Model Voltage Amps CT Size VE/H8043-0100-2 208 100 small VE/H8043-0300-2 208 300 small VE/H8043-0400-3 208 400 medium VE/H8043-0800-3 208 800 medium VE/H8043-0800-4 208 800 large VE/H8043-4600-4 208 1600 large VE/H8043-2400-4 208 2400 large VE/H8044-0100-2 480 100 small VE/H8044-0300-2 480 300 small VE/H8044-0400-3 480 400 medium VE/H8044-0800-3 480 800 medium VE/H8044-0800-4 480 800 large VE/H8044-1600-4 480 1600 large VE/H8044-2400-4 480 2400 large

Veris Current Switch & Relay • Independent switch & relay operation • Command & status in one device • Adjustable setpoint • Relay & switch status LEDs simplify setup

®

SPECIFICATIONS Current Range: Sensor Power: Insulation Class: Frequency Range: Temperature Range: Humidity Range: Setpoint Adjustable: Hysteresis: Dimensions: Sensor Opening:

1-135A Induced 600VAC rms 50/60Hz. -15° to 60°C 0-95% non-condensing 1-135A 10% Typical 2.95" x 2.68" x 1.04" 0.75" (19mm) Dia.

ORDERING INFORMATION

H735

L

Model Relay Contacts* VE/H735 Form A (SPST) 5(3)A@250VAC, 30VDC, 1/6HP VE/H738 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP VE/H739 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP VE/H748 Form C (SPDT) 8(3.5)A@250VAC, 30VDC, 1/4HP VE/H749 Form C (SPDT) 8(3.5)A@250VAC, 30VDC, 1/4HP VE/H758 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP VE/H759 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP * Resistive load (inductive load).

Also available in split core style (H930 series)

103

Coil 24VAC/DC 10mA 24VAC/DC 10mA 24VAC/DC 10mA 24VAC/DC 10mA 24VAC/DC 10mA 9-12VDC 10mA 9-12VDC 10mA

Solid State Output 0.1A@30VAC/DC N.O. 1.0A@30VAC/DC N.O. 0.2A@120VAC/DC N.O. 1.0A@30VAC/DC N.O. 0.2A@120VAC/DC N.O. 1.0A@30VAC/DC N.O. 0.2A@120VAC/DC N.O.


NK Technologies AC Current Switches

AS and ASX current switches combine a current sensor, signal conditioner, and limit alarm in a single package. AS1 series are well suited to automation systems of all kinds with their universal solid-state outputs and a wide frequency response. AS3 series have a high current output that works well with relay logic control schemes. ASX series combine the AS3 design with a built in adjustable time delay. All models feature high visibility LED indication and rugged construction. AC monitoring models are available in solid and split core cases.

FF Case Style

L

If you control or monitor electric powered loads, you need current switches. Monitor fans, pumps, lights, and heaters for proper operation. Current switches give positive feedback that the load is operating and are much easier to install than alternatives like pressure switches, optical sensors, or zero speed switches.

L FT Case Style

SP Case Style

L

SPECIFICATIONS Power Required: Setpoint Range:

Frequency Range: Outputs Solid State N.O.: Solid State N.C.: Solid State -15 Option: Off State Leakage: Response Time: Hysteresis: Sensing Aperture: Case: Environmental: Listings:

AS3 Series None — Self Powered 1–6, 6–40, 40–175A (fixed core) 1–6, 6–40, 40–200A (split core) UL Listed to 1270 VAC

6–100 Hz

6–100 Hz

UL Listed (pending) to 1270 VAC 50-100 Hz

0.2A @ 240 VAC/VDC 0.2A @ 135 VAC/VDC N/A None 0.120 Second 5% of Setpoint 0.55", 14 mm Dia. (FF Case) 0.75", 19 mm Dia. (FT Case) 0.85", 21.5 mm Sq. (SP Case) UL 94V-O Flammability Rated -58 to 149° F (-50 to 65° C) 0–95% RH, Non-condensing UL and ULC 508 Listed, CE

1A @ 240 VAC 1A @ 240 VAC 15A @ 120 VAC, 10A @240 VAC NC only: 2.5 mA 0.120 Second 5% of Setpoint 0.55", 14 mm Dia. (FF Case) 0.85", 21.5 mm Sq. (SP Case)

1.0A @ 240 VAC 1.0A @ 240 VAC N/A NC only: 2.5 mA 0.1 Second 5% of Setpoint 0.75”, 19 mm Dia. (FT Case) 0.85”, 21.5 mm Sq. (SP Case)

UL 94V-O Flammability Rated -58 to 149° F (-50 to 65° C) 0–95% RH, Non-condensing UL and ULC 508 Listed, CE

UL 94V-0 Flammability Rated 5 to 158 ° F (-15 to 70 ° C)

TRANSDUCERS / SENSORS

Isolation Voltage:

NEW ASX Series None — Self Powered 1.5-12, 12-55, 50-200 A

AS1 Series None — Self Powered 1–150A (fixed core) 1.5–150A (split core) UL Listed to 1270 VAC

UL and ULC 508, CE (pending)

ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number.

Example: AS1 - NCU-FT A – B – C – D

A B

Basic Model AS1 AS3, ASX Output NOU NCU NOAC NCAC

C AC Sensing, Single Range AC Sensing, 3 Ranges AS1 Normally Open AS1 Normally Closed AS3, ASX, Normally Open AS3, ASX, Normally Closed

D

Case and Connection FF Fixed Core, Front Connection FT Fixed Core, Top Connection (AS1, ASX only) SP Split Core Options GO Fixed GO/No-GO Setpoint (AS1 only) (blank) Adjustable Setpoint NL No LED (AS1, AS3 only) 15 15A @ 120 VAC Output (AS3 only)

104


Noshok Pressure Transducers and Transmitters

FM

L

TRANSDUCERS / SENSORS

615/625

Series 1800 Attachable Loop Indicator

105


L

Noshok Pressure Transducers and Transmitters

100

TRANSDUCERS / SENSORS

106


Noshok Pressure Transmitter • Up to 20:1 Span Turn Down • Proven D iffused S emiconductor or Sputt ered T hin Film Stra in Gage T echnology • Built-in Process T emperature D isplay • Built-in S electable Process D igital Filtering • Welded 316 S /S Pressure Chamber • 32 Point Process Linearization • Adjustable D isplay for Easy Viewing • 12 D ifferent Measurement Un its • CE Compliant The NOSHOK Series 750 digital pressure transmitter combines the reliability and long life of diffused semiconductor and sputtered thin film strain gage sensors with digital electronics for outstanding performance and value. With up to 20:1 span turn down and -2.5 to 99% zero point adjustment there is maximum flexibility to meet the most unusual application requirements. Additional features including 32 point process linearization, adjustable display orientation and integral process temperature measurement give the Series 750 an advantage over many other pressure transmitters.

106a

▲ 750

106


Ashcroft Digital Pressure Gauges • 4 1/2" Digit Display, 1/2" Character Height • Maximum Pressure Indication • Selectable Engineering Units • Chemical Resistant Case • Optional Weatherproof Boot The D1005PS is a versatile and economical choice for general pressure applications. Stainless steel wetted parts are suitable for dry air and many other media. Popular features such as backlight, peak hold and engineering units display are standard on the D1005PS.

• 1/4% Full Scale Accuracy • Extra Large 5 Digit Display • 4-20mA & Switch Outputs in One Unit (2274) • NEMA4, IP65 Case • Selectable Damping, Update Rate, Engineering Units, Auto-Off • Min/Max (Peak Hold) Display

L D1005PS

SPECIFICATIONS 2 1/2", Noryl® /2% FS standard, 1/4% available 1 /4 NPT, bottom 2 AAA batteries 4 level battery indicator in display -10°C to 60°C (14-140°F) 200%, up to 1000psi 150%, 3000 & 5000psi 120%, 9999psi

Case Size: Accuracy: Connection: Power:

TRANSDUCERS / SENSORS

Keypad Functions: Auto/Off: Backlight: Max (Peak Hold): Zero/Clear: Engineering Units:

Never, 5, 10, 20 minutes 4 auto off options Displays peak value Zeroes display or clears max value psi, in.H2O, cmHg, mmHg, kPa, mPa, Bar, kg/cm2, ft.H2O Zero and span

Field Calibration:

ORDERING INFORMATION To Order - Insert Range Code and Units to Complete Catalog Number. AS/D1005PS02L–30psi AS/D1005PS02L – A Range (include units suffix) psi 30 60 100 200 300 500 1000 3000 5000 9999 10000 15000 19999

L

SPECIFICATIONS

1

Temperature: Proof Pressure:

A

Specify these multi-function digital gauges when any combination of local indication, 4-20mA output and switching is 2174 required. Easy menu configuration speeds installation & setup. All points between zero and full scale remain within stated accuracy even after rezeroing.

ftH20 70 140 230 460 700

Also available: kPa, MPa, bar, kg/cm2 pressure ranges; kPa, mmHg, cmHg, bar, kg/cm2 vacuum ranges; kPa, bar, kg/cm2, ftH20 compound ranges.

inH20 -30/0 (vacuum)

inHg/psi -30/30 -30/60 -30/100 -30/150 -30/300 (compound)

Options: ±0.25% of span accuracy Protective boot 3, 9, 12 o'clock connections

(3") 0.6”, (41/2") 0.88" 10 segment % of range 10-60°C (14-140°F) 200% 12-36 VDC (3") Two AA, (41/2") Two C 30VDC/1A, 25VAC/0.5A CE, FM, CSA

Digit Height: Bargraph: Temperature: Proof Pressure: Loop Power: Battery: Switch Rating: Approvals:

ORDERING INFORMATION To Order - Insert Code for Each Letter to Select Catalog Number. Example AS/302274SD02L –100psi–XU1BL AS/

A

B

C

D – E – F

A Case 30 3" stainless steel 45 41/2" thermoplastic B Model 2074 Battery powered 2174 Loop powered, 4-20mA output 2274 Line powered (12-36 VDC, 2VA) C Wetted Parts SD 316 stainless steel (socket) 17-4 stainless steel (sensor) D Connection 1 02L /4 NPT 1 04L /2 NPT (41/2" case only)

E Range (include units suffix) psi 30 60 100 160 200 300 600 800 1000 1500 2000 3000 5000 8000 10000 15000 20000

ftH20 30 60 160 200 200 300 400 600 1000

inH20* 800 1000

mmH2O 60 100 160 200 300 400 600 800 1000

* 20°C, 60°C & 4°C reference options

107

F Options X followed by one or more 2 digit codes: AY Black aluminum case for 41/2" size EC Electro polished case for 3" size U1 One SPDT switch (2274 only) U2 Two SPDT switch (2274 only) AO 4-20mA output for 2274 EN Flying leads for 41/2" case (terminal blocks std for 41/2" case, flying leads std for 3" case) BL Display backlight BK Battery backup for 2174 & 2274 S7 Weatherproof carry case (3" only) B1 Black rubber boot (3" only) B2 Orange rubber boot (3" only) PP Protective front cover (3" only) inHg 60 100 160 200 300 400 600 800 1000 1600 2000 3000 6000

mmHg 1500 2000 3000

compound 15#/vac 30#/vac 60#/vac


Ashcroft Pressure Gauges • 4 1/2", Grade 2A (±0.5% FS) • Long Life, Teflon Coated Movement • Adjustable, Self-Locking Pointer • Temperature Compensated • Liquid-Filled Performance in a Dry Gauge (option XLL)

• 4 1/2", Grade 2A (±0.5% FS) • 4-20 mA, 2-Wire Output • Adjustable Zero & Span • Hermetically Sealed Phenolic Case • FM Approved to 10,000psi Reliable Duragauge® construction provides the analog pressure indication. An isolated optical sensor drives the transmitter output.

L

The 1279 series is designed for long life in harsh industrial applications. The phenolic case provides superior chemical and heat resistance. Five bourdon tube systems handle a wide range 1279 Duragauge® of pressures and a variety of media. The Plus!™ Performance option (XLL) reduces the effects of pulsations and vibrations without the maintenance problems of liquid filling.

2279 Duratran®

L

ORDERING INFORMATION To Order - Insert Code for Each Letter to Select Catalog Number. Example: AS/1279BS02LXLLSG-0/3000psi AS/451279

A

B

C

D – E

psi 0/15 0/30 0/60 0/100 0/160 0/200 0/300 0/400 0/600

0/800 0/1000 0/1500 0/2000 0/3000 0/5000 0/10000 0/20000 0/30000

Compound 30"Hg/15psi 30"Hg/30psi 30"Hg/60psi 30"Hg/100psi 30"Hg/150psi 30"Hg/300psi

Vacuum 30/0 inHg 34/0 ftH20

-40°F to 160°F 130% of range w/o damage to tube 12-40VDC 500Ω max at 24V, 1kΩ max at 36V Transmitter span & zero adjustment on dial, Gauge zero adjustment on pointer Phenolic, hermetically sealed Laminated safety glass 30" leads, 1/2" liquid tight conduit fitting

Case: Lens: Electrical:

ORDERING INFORMATION To Order - Insert Code for Each Letter to Select Catalog Number. Example AS/452279P04LXFMLL – 0/3000psi AS/452279

A

B

C

TRANSDUCERS / SENSORS

AS/451279 41/2" Duragauge, grade 2A A Tube/Socket Material (max. psi) A Phosphor bronze/brass (1000) B 4130 steel/1019 steel(5000) R 316 stainless/1019 steel (20000) S 316SS/ 316SS (20000) P K Monel/Monel 400 (30000) B Case S Solid front SH Solid front, hermetic seal SL Solid front, liquid fill C Connection 1 /4 NPT, lower 02L 1 04L /2 NPT, lower 1 02B /4 NPT, back 1 04B /2 NPT, back D Options X followed by 1 or more 2 digit codes LL Dynamic dampening OS Overload stop TS Throttle screw SG Safety glass PD Plastic window NN Paper tag NH Stainless steel tag GV Silicone filled E Range (include units suffix)

SPECIFICATIONS Operating Temperature: Overpressure: Power Supply: Loop Resistance: Adjustments:

D – E

1

AS/ 2279 4 /2" Duratran, grade 2A A Tube/Socket Material S 316SS / 316SS P K Monel / Monel 400 B Case SH Solid front, hermetic seal C Connection 1 04L /2 NPT, bottom D Options X followed by 1 or more 2 digit codes: LL Dynamic damping FM FM approval PD Plastic window NN Paper tag NH Stainless steel tag GB Oxygen cleaned E Range ( add psi suffix) psi 0/12 0/15 0/30 0/60 0/100 0/160 0/200 0/300 0/400

0/600 0/800 0/1000 0/1500 0/2000 0/3000 0/5000 0/10000 0/20000

Metric, vacuum, compound, dual scale & receiver gauge dials available on request. Use 2288 series for lower ranges

Metric ranges also available. Other features and options available on request. Call for information on other Ashcroft dial gauges, including: • Type 1009 2 1/2" & 3 1/2" Process Gauges, with ranges from vacuum to 15000 psi (Grade 1A, ±1% FS) • Type 1083 3" Test Gauges, with ranges from vacuum to 1000 psi (Grade 2A, ±0.5% FS)

108


Ashcroft Test Gauges

Ashcroft Pressure Switches

• Rugged & Portable • 0.05% FS Total Error Band • 0.66" Display Characters • NEMA 4, IP65 Stainless Steel Case • Selectable Damping, Update Rate, Engineering Units, Languages • Meets ASME B40.7

• Long Life Sensor & Relay (>10 million operations) • Watertight Metal Enclosure • Deadband Adjustable to 0.5% • Bright Local Display (optional)

These Precision Digital Test Gauges are available with 0.05%, 0.1% or 0.25% total error band (TEB) accuracy. TEB accuracy includes the effects of linearity, hysteresis, repeatibility and 2089 temperature from 0 to 150°F. Ashcroft uses the conservative terminal point accuracy method for TEB. This allows rezeroing to eliminate sensor offset. All points between zero and full scale remain within stated accuracy.

This electronic pressure switch will outlast mechanical switches in high cycle applications. The pressure sensor is a stable thin film transducer with proven reliability and long life. The adjustable, narrow deadband solves many pipeline and elevated NPI tank applications that cannot be satisfied with mechanical products. An optional LED display provides local pressure indication and simplifies switchpoint setup.

SPECIFICATIONS SPECIFICATIONS Dial: Case: Proof pressure: Display: Bargraph: Temperature: Battery: EMI:

3" 300 series stainless steel, electroplated, weatherproof 2X gauge pressure 41/2" digit backlit LCD 10 segment % of range -18 to 63°C (0-150°F) 3 AAA, >1000 hours CE EN50082-1 (1997)

Keypad Functions Engineering Units:

psi, "Hg, "H2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O, mmH2O, kg/cm2 10/sec, 5/sec, 2/sec, 1/sec 2, 5, 15, 30 min, never None, 2, 4, 6, 8 readings Stores min/max values when dispalyed Zeroes display or clears min/max values on/off, 10 sec., 30 sec., 1 min., 5 min. English, Spanish, French, Italian, German, Portuguese, Dutch Seven levels 10 points, password protected Scroll thru menu & option choices

Update Rate: Auto off: Dampening: Min/Max: Zero/Clear: Backlight: Language: Contrast: Calibration: Configuration:

ORDERING INFORMATION To Order - Insert Code for Each Letter to Select Catalog Number. Example AS/302089SD0L–100psi–XDB1 AS/30 A

B C D

A

B

C – D – E

Model 2089 0.05% FS accuracy 2086 0.10% FS accuracy 2084 0.25% FS accuracy Wetted Parts SD 316 stainless steel Connection 02L 1/4 NPT, lower Range (include units suffix) psi 10 15 30 60 100 160 200 (2) 300 500

600 800 1000 1500 2000(2) 2500(1) 3000 5000 7000

Compound psi (absolute) 15#/vac 15 30#/vac 25(1) 50

E

Options XD 3 o’clock connection XE 9 o’clock connection B1 Black rubber boot B2 Orange rubber boot NH Metal Tag NN Paper Tag CD1 Certificate of Conformance C4 Certified Calibration data (standard w. 2089)

Temperature options 4°C, 20°C, 60°F. Metric units available on request. (1) 2086 and 8084 only. (2) Accuracy meets ASME B40.7 resolution requirements through 199.9 psi (200 psi) and 1999.9 psi (2000 psi).

Enclose:

Display: Status Lights: Output: Life:

Epoxy coated aluminum NEMA 3, 4, 4X, 13 & IP66 Optional NEMA 7, 9 & Div I or II hazardous locations 14-4 PH stainless steel diaphragm AISI 316 stainless steel fitting 31/2 digit LED indicates process pressure ±1% Process pressure, set pressure, reset pressure, relay output SPDT Relay rated 10A @250VAC/30VDC >10 million operations at rated load

Electrical:

3/ 4

Wetted Parts:

NPT connection

ORDERING INFORMATION To Order – Insert Number Code for Each Letter to Select Catalog Number. Example: AS/NPAN7DCS02-100psi AS/

A

B

C

D

E

F – G

A Function G Range NPA Single setpoint, adjustable deadband psi NPI Single setpoint, adjustable deadband, process and 60 setpoint display 100 B Enclosure N4 Watertight NEMA 3,4, 4X, 200 13 & IP66 N7 Explosion proof NEMA 3, 4, 4X, 300 13, 7, 9 & IP66 (NPA only) 500 C Output D SPDT Relay 750 D Power Equipment L 110VAC, 50/60Hz 1000 C 24VDC 2000 V 250VAC, 50/60Hz E Pressure Port 3000 1 S01 /8 NPT Male 1 S02 /4 NPT Male 5000 1 S03 /8 NPT Female 1 S04 /4 NPT Female 7500 7 1 S05 /16 –20 SAE – /4 SAE 1 1 10000 S06 /2 NPT Male & /4 NPT Female 1 S07 /4 AMINCO – Female 15000 F Option XEA External Setpoint Adjustment 20000 — None

Setpoint Limits

psi Proof

psi Burst

3-60

120

480

5-100

200

800

10-200

400

1600

15-300

600

2400

25-500

1000

4000

35-750

1500

6000

50-1000

2000

8000

100-2000

4000

16000

150-3000

4500

20000

250-5000

7500

22500

375-7500

9000

25000

500-10000

12000

30000

750-15000

18000

45000

1000-20000 24000

60000

108a


Kobold Temperature Transmitters L

• 4-20mA Output • Hermetically Sealed Electronics • Easily Re-Programmable via PC • Low Cost and Easy Installation

TST

The TST transmitter fits in a low profile housing which is only 2" long. PC calibration software allows temperature range, offset, burnout options and other features to be field selected without recalibration.

SPECIFICATIONS Maximum Pressure: Threaded Version: Tri-clamp Version: Probe Material: Power Required: RTD Type: Output Accuracy: Ambient Temperature:

1500 PSIG 500 PSIG 316 Stainless Steel 9-30 VDC loop powered Pt100, class B ±0.1% of Span -40°F to 158°F

• 4-20mA Output, Loop Powered • Rugged 316 SS Construction • -200 to 600°C Range • Adjustable Zero & Span The TMA series is factory calibrated. Zero and span potentiometers are accessible at the connector for recalibration.

SPECIFICATIONS Ambient Temperature: Max. Pressure: Probe: Power Required: RTD Type: Output Accuracy: Connector: Protection:

L

TMA with optional AUF display

ORDERING INFORMATION

ORDERING INFORMATION

TRANSDUCERS / SENSORS

-40°C to +70°C 1450 PSIG 316 SS, 1/4" dia 12-36 VDC Pt100, class B ±0.1% of Span Hirshmann plug NEMA 4X, IP65

To Order - Insert Code for Each Letter to Select Catalog Number.

To Order - Insert Code for Each Letter to Select Catalog Number.

Example KO/TST-A4-040-PV-06-C

Example KO/TMA-S2514A-025-05

KO/TST - A – B – C – D – E

KO/TMA - A – B – C

A Fitting Style 1 A2 /4" NPT, Adjustable immersion depth 1 A4 /2" NPT, Adjustable immersion depth 1 F2 /4" NPT, fixed immersion depth 1 F4 /2" NPT, fixed immersion depth T15 1 1/2" Tri-clamp T2 2" Tri-clamp T25 2 1/2" Tri-clamp T3 3" Tri-clamp B Available Immersion Depth 025 2.5" 040 4" 060 6" 090 9" 120 12" 180 18" 240 24" EP Custom (specify) C Cable (6' standard length) PV PVC jacket (220°C process max) TF Teflon jacket TA 316 SS armored TB 316 SS braided 0 None (use for option H)(BELOW) D Available Measuring Range 02 0 to 120°F 04 0 to 200°F 06 0 to 300°F 08 0 to 400°F 10 0 to 500°F 12 0 to 750°F 14 0 to 950°F 16 0 to 1100°F 18 -58 to 120°F E Custom scaling (specify) E Options C 1/2" NPT conduit hub H DIN43650 Hirshmann Plug in place of cable EC Extended cable length, specify length KO/TST-PKIT Field calibration kit includes 9pin serial cable, 110VAC power pack & Windows software

A Fitting Style 1 S2514F /4" NPT, Fixed immersion depth 1 S2512F /2" NPT, Fixed immersion depth 1 S2514A /4" NPT, Adjustable depth 1 S2512A /2" NPT, Adjustable depth B Available Immersion Depth 025 2.5" 040 060 6" 090 120 12" C Available Measuring Range 05 0 to 50°C (32/122 °F) 10 0 to 100°C (32/212°F) 15 0 to 150°C (32/302°F) 20 0 to 200°C (32/392°F) 40 0 to 400°C (32/752°F) 60 0 to 600°C (32/1112°F) 55 -50 to 50°C (-58/122°F) 51 -50 to 150°C (-58/302°F) 24 -200 to 400°C (-328/752°F) 26 -200 to 600°C (-328/1112°F) E Custom (specify)

The AUF display can be added to any 4-20 mA output that uses the Hirshmann connector. Installed between the transmitter and the cable, the AUF is fully scalable through two control buttons. Power is provided by the 4-20 mA loop, so no additional power supply is required.

SPECIFICATIONS Display: 4-digit red LED 5/16" tall Range: -1999 to 9999 Loop Voltage Load: 5 volts

Sampling Rate: 0.33-20s, adjustable Switch: Open Collector, 60mA max.,PNP Protection: NEMA 4

ORDERING INFORMATION KO/AUF1000

109

4" 9"

Local Digital Display

KO/AUF1001

Local Display w/Alarm


Raytek Infrared Temperature Sensors CI Series Compact Infared Sensor

MI Series Miniature Infrared Sensors

• • • •

• Adjustable Emissivity, Peak/Valley Hold & Averaging • 1% Accuracy from –40 to 600°C (-40 to 1112°F) • 10:1 Optics • Sensing Head Accessible for Cleaning • RS-232 Communications (RS-485 optional)

Type J or K, or 0-5 V Output IP 65 (NEMA-4) Stainless Steel Electronics Housing 4:1 Optics at 90% Energy Powered by 12-24VDC at 20mA

Replaces traditional probes with J-type or K-type thermocouple output. Functions accurately when used in conjunction with the thermocouple break protection circuitry in most controllers, displays, and transmitters.

SPECIFICATIONS 7 to 18 µm ±2% or ±3°C 0.5°C 350ms (95%) fixed at 0.95 4:1 1m (3.3') standard 50Ω 50kΩ 12–24VDC ±5%, 20mA 0 to 70°C up to 90°C up to 260°C 10 to 95%, non-condensing 0.75" dia. x 3.4" long

SPECIFICATIONS Resolution Temperature Range Outputs Output Impedance (T/C) Minimum Load Impedance (mV) Maximum Loop Impedance Power Environmental Rating Ambient Temperature: MID Sensing Head MIC Sensing Head MIH Sensing Head With air cooling Electronics housing Temperature Coefficient Size

ORDERING INFORMATION RA/CI-1A RA/CI-2A RA/CI-3A RA/CI-1B RA/CI-2B RA/CI-3B

IR Temperature Sensor, J T/C, 0-155°C IR Temperature Sensor, K T/C, 0-155°C IR Temperature Sensor, 10mV/°C Linear Voltage, 0-155°C IR Temperature Sensor, J T/C, 100-500°C IR Temperature Sensor, K T/C, 100-500°C IR Temperature Sensor, 10 mV/°C Linear Voltage, 100-500°C

OPTIONS / ACCESSORIES -10L -W RA/CIADJB RA/CIACFB RA/CIACRA RA/CIAP RA/CI1CON RA/CI2CON RA/CIACCB10H RA/CIACCB5OH

3m (10') Cable, 105°C Air/water cooled jacket with lens purge & 1m (3.3') 260°C cable Adjustable mounting bracket Fixed mounting bracket Right angle mirror Air purge collar Thermocouple cable extension connector kit for CI1 Thermocouple cable extension connector kit for CI2 3 Meter (10', 260°C) extension cable 15 Meter (50', 260°C) extension cable

Spectral Response: System Accuracy: LT Thermocouple output Repeatability System Response Time Emissivity Transmission

0.3°C or 0.5°F -40°C to 600°C (-40°F to 1112°F) -25°C to 600°C for J T/C Output 4-20mA, 0-20mA, 0-5V (scaleable) J or K thermocouple 10 mV/°C head ambient signal 20Ω 100kΩ (mA output) 500Ω with 24VDC power supply 11-26VDC, 100mA IP65 (NEMA-4) 0 to 85°C (32 to 185°F) 0 to 125°C (32 to 257°F) 0 to 180°C (32 to 356°F) up to 200°C 0 to 65°C MID 0.15K/K or 0.15%/K MIC, MIH 0.05K/K or 0.05%/K Sensor 0.55" dia x 1.1" long Housing 3.2" x 2.4" x 1.0" 8 to 14 µm (18-28°C ambient) ±1% or ±1°C ±1% or ±2.5°C ±0.5% or ±0.5°C 150ms (95%) 0.100 to 1.100 digitally adjustable

ORDERING INFORMATION RA/MID-10LT Univ. Output, 10:1 optics, 1m cable, 85°C max sensor ambient RA/MIC-10LT Univ. Output, 10:1 optics, 1m cable, 125°C max sensor ambient RA/MIH-10LT Univ. Output, 10:1 optics, 1m cable, 185°C max sensor ambient

OPTIONS/ACCESSORIES -4 - CB3 - CB8 - CB15 -V RA/XXXMIACFB RA/XXXMIACAB RA/XXXMIACAJ RA/XXXMIACCJ RA/XXXCIDCPS

RS485 Multidrop Communication 3m (10') Cable 8m (26') Cable 15m (49') Cable Display window in electronic housing Fixed Mounting Bracket Adjustable Mounting Bracket Air Purge Collar Air Cooling and Purge System (includes 2.8' insulated air hose) Power Supply, 24VDC

110

TRANSDUCERS / SENSORS

Spectral Response Accuracy Resolution Response Time Emissivity D:S Ratio Cable Output Impedance (J/K) Minimum Load (mV) Power Ambient Temperature: Sensing head With air cooling With water cooling Relative Humidity Size

Two-piece infrared temperature measurement system with a miniature sensing head and die-cast electronics housing.


Raytek Programmable IR Sensors

Kobold Ultrasonic Level Transmitter • Measuring ranges to 23 feet in liquids, 11.5 feet in solids • Narrow 5.5° beam angle • PVDF wetted parts • Accuracy 0.25% of full scale • 2-wire and 4-wire versions

L CM

TRANSDUCERS / SENSORS

• • • • • • •

-20 to 500°C (-4 to 932°F) Range 13:1 Optics at 90% Energy 150ms (95%) Response Time RS-232 Digital Communications Adjustable Signal Processing DataTemp® Multidrop Software Compatible Sensor status indicator LED

Designed for easy integration, the CM sensor with J-type or K-type thermocouple output can easily replace traditional contact probes. A user scalable 0-5 volt output is available for applications susceptible to noise. This rugged, single piece NEMA4 sensor has silicon optics to provide excellent optical resolution.

SPECIFICATIONS Accuracy (mV): Accuracy (T/C): Spectral Response: Resolution: Emissivity: Transmissivity: Signal Processing: Output: Self-diagnostics: Power Supply: Digital Output: Alarm Output: Ambient Temperature: Housing: Size: Cable:

± 1.5% of reading or ± 2ºC ± 1.5% of reading or ± 4ºC 8 to 14 microns 0.1°C 0.10 to 1.10 (adjustable) 0.10 to 1.00 (adjustable) Peak hold, valley hold, variable averaging 100Ω Zout (TC types) 50kΩ min load (Voltage type) Alarm, out of range, unstable, fault 12–24 VDC ±20% @ 10mA Two-way RS232 digital output Transistor, 24VDC ±20% <20mA 0-70°C (32-160°F) IP 65 (NEMA-4) stainless steel 0.75" dia x 3.7" long, 3/4-16 UNF thread 1m (3.3 ft) standard, 3m available

ORDERING INFORMATION RAYCMLTV RAYCMLTJ RAYCMLTK Add suffix 3 for 3m (9.8') cable

111

CM sensor, 0-5V user-scalable output CM sensor, Type J TC output CM sensor,Type K TC output

The NUS series Ultrasonic Level Transmitter is ideal for continuous, non-contact level measurement in liquids and coarse grained or pelletized solids. This sensor allows reliable measurement of dirty, viscous, and coating medium. The NUS boasts an extremely narrow beam to minimize problems due to obstructions in tall tanks. In addition to the 4-20mA output, a front panel LED readout is available.

L 2083

The NUS series offers many advanced features including 11 point linearization, fixed echo suppression, automatic stirrer echo suppression and output dampening. These features allow the NUS series to be used in applications which render most other ultrasonics useless. Calibration and setup is a simple task performed using a push-button driven menu.

SPECIFICATIONS Maximum Pressure: Process Temperature: Accuracy: Resolution: Beam Cone Angle: Maximum Loop Load: Optional Display: Case: Protection: Electrical Connection: Measuring Range 2" NPT Models: 1 1/2" NPT Models:

40 PSIG -40°F to 176°F 0.25% of Max. Range ±0.12" 5.5° 600Ω 4 digit LED Epoxy coated Aluminum NEMA 4X, IP65 1 /2" NPT 1.3 to 23.0 ft in liquids, 1.3 to 15 ft in solids 0.8 to 13.1 ft in liquids, 0.8 to 6.6 ft in solids

ORDERING INFORMATION KO/NUS-1053N KO/NUS-1051N KO/NUS-2053N KO/NUS-2051N KO/NUS-1083N KO/NUS-1081N KO/NUS-2083N KO/NUS-2081N

1 1/2" fitting, 12-36VDC, 2-wire Transmitter 1 1/2" fitting, 90-127VAC, 4-wire Transmitter 1 1/2" fitting, 12-36VDC, 2-wire with Display 1 1/2" fitting, 90-127VAC, 4-wire with Display 2" fitting, 12-36VDC, 2-wire Transmitter 2" fitting, 90-127VAC, 4-wire Transmitter 2" fitting, 12-36VDC, 2-wire with Display 2" fitting, 90


Alaron Vibration Transmitter Alaron Vibration Transmitters • Two Wire, Loop Powered • 4–20 mA Output • Easily Interface To Panel Meter, Data Logger, PLC or PC • Rugged PZT Sensor • NEMA 4X Stainless Steel Housing The VT100 series is ideal for use with all types of rotating machinery. Continuously monitor machine vibration levels and locate problems before catastrophic failures occur. The transmitter easily mounts with a 1/4–28 stud (included).

Kobold Low Flow Sensor • 0.4 to 400 GPH sizes • Compact Size, Low Cost • Resistant to Aggressive Media The DPL Series is ideal for applications requiring accurate flow measurement of transparent liquid media. A paddle wheel turbine interrupts an internal infra-red beam to generate a frequency output proportional to flow. The sapphire axle and bearing system assures long service life.

SPECIFICATIONS Accuracy Sensitivity Frequency Range Supply Voltage Isolation Electrical Connector Temp. Range Shock Case Size

Better than 5% <0.003"/ sec 5 Hz to 1500 Hz 12 to 40 VDC unregulated 800V circuit to case Microfast high temp. & oil resistant -10 to 100°C 500G NEMA 4X Hermetically Sealed 1.8" long x 1.1" dia.

ORDERING INFORMATION VT100 VT200 VT500 WKB3T-3 KB3T-3

Vibration Transmitter, 0 to 1"/sec. velocity w/o cable Vibration Transmitter, 0 to 2"/sec. w/o cable Vibration Transmitter, 0 to 5"/sec. w/o cable 10' cable with right angle connector 10' cable with straight connector

Alaron Machine Condition Monitor

SPECIFICATIONS Detector Power: Output Sink: Pull-up: Output Signal: Emitter LED: Supply: Forward Voltage: Wiring: Accuracy: Wetted Parts Body: Seals:

Fittings: Max. Pressure: Temperature: Protection:

4.6-16 VDC, 15mA max. 18mA max. Internal 10kohm Frequency 15-50mA, 1.2-1.5VDC 6 ft. PVC cable ±5% of full scale

Polypropylene, sapphire, polysulfone Buna-N standard, Viton, EPDM optional

/2" bsp standard, hose-barb 1/2" PVC optional 145 PSIG -40°F to 160°F NEMA 4X 1

ORDERING INFORMATION

The VDS104 measures 4 channels of vibration, temperature or any 4-20mA sensor output. Each channel includes a 0-5V analog retransmit, 2 status LEDs, and 2 relay outputs with adjustable setpoint & delay. Unit is housed in a 12"x8"x6" NEMA 4X case with 4 line LCD display. Powered from 120/220VAC, the VDS104 will provide loop power to all 4 channels.

ORDERING INFORMATION VDS104 Machine Condition Monitor

111a

Model KO/DPL-1005 KO/DPL-1018 KO/DPL-1060 KO/DPL-1120 KO/DPL-1250

Range GPH 0.4 - 8.0 0.8 - 28 3.0 - 95 6.0 - 190 16 - 400

oz/sec 0.014 - 0.28 0.028 - 1.0 0.11 - 3.4 0.21 - 6.8 0.57 - 14

Nom Freq. at max flow (Hz) 272 471 528 300 399

OPTIONS -V -E -S -F2 -F4 -F8 -C

Viton seals EPDM seals Hose Barb fittings, 1/2" PVC 1/2 frequency 1/4 frequency 1/8 frequency ±1.5% accuracy calibration

Max DP (PSI) 11 11 10 15 19


Pyromation Insulated Thermocouples The thermocouple element is encased in a metal sheath that can be formed and bent. Extension leadwire of the same thermocouple material connects to remote panel meters or transmitters. Sheath fittings can be specified to mount the probe in thermowells with NPT threads. Standard or Miniature Thermocouple Plugs are available to simplify field installation. These can be ordered with or without extension leadwire.

SPECIFICATIONS

Thermocouple Extension Wire Ext. Wire Temperature Type Range KX 0 to 200°C (32 to 392°F) JX 0 to 200°C (32 to 392°F) EX 0 to 200°C (32 to 392°F) TX 0 to 100°C (32 to 212°F) NX 0 to 200°C (32 to 392°F)

Reference Junction 0°C (32°F) Limits of Error Standard Special ± 2.2°C (4°F) ± 1.1°C (2°F) ± 0.75% ± 0.4% ± 2.2°C (4°F) ± 1.1°C (2°F) ± 0.75% ± 0.4% ± 1.7°C (3°F) ± 1°C (2°F) ± 0.5% ± 0.4% ± 1° C (2°F) ± 0.5°C (1°F) ± 0.75% ± 0.4% ± 2.2°C (4°F) ± 1.1°C (2°F) ± 0.75% ± 0.4% Reference Junction 0°C (32°F) Limits of Error Standard Special ± 2.2°C (4°F) -----± 2.2°C (4°F) ± 1.1°C (2°F) ± 1.7°C (3°F) -----± 1.0°C (2°F) ± 0.5°C (1°F) ± 2.2°C (4°F) ------

* For sheathed thermocouples without leadwire or plug, part number ends with H

Example

Sheath Terminations 10(1) Sheath stripped 1" 10(2) Sheath stripped 2" 10(3) Sheath stripped 3" PM/J43GM-012-00-10(1)

To Order: Insert Code for Each Letter to Select Catalog Number Order Example PM/J43GM-012-10B-15-F3-036-2 ABCDE-F-G-H-I-J-K A Thermocouple Type PM/J Type J PM/K Type K PM/E Type E PM/T Type T PM/N Type N B Sheath Diameters 1 1/16" (0.063) 2 1/8" (0.125) 3 3/16" (0.188) 4 1/4" (0.250) 6 3/8" (0.375) C Sheath Material 8 316 stainless steel (type J, K, E, T) 3 Inconel 600 (type J, K, E, T) 9 304 stainless steel (type J, K, N) D Junction Type G Grounded U Ungrounded E Limits of Error Standard M Special F Sheath Length nnn Three digit sheath length in inches G Re-Adjustable Compression Fitting 00 None 10B 1/4" NPT SS for 1/4", 3/8" sheath OD 10C 1/2" NPT SS for 3/16", 1/4" 11B 1/4" NPT Brass for 1/8", 3/16", 1/4", 3/8" 11C 1/2" NPT Brass for 1/4", 3/8" H Leadwire Transition* 15 Relief spring (400°F rating) 13 Same size transition 00 None I Extension Leadwire F3 Fiberglass (stranded) F3B Fiberglass with stainless steel overbraid (stranded) T3 Teflon (stranded) T3B Teflon with stainless steel overbraid (stranded) 00 None J Leadwire Length nnn Lead length in inches using 3 digits K Wire Terminations 2 2" split leads 3 2" split leads w/ spade lugs 4 Standard male plug 6 Miniature male plug 4MC Standard male plug with mating connector 6MC Miniature male plug with mating connector Other types and configurations available on request

112

TRANSDUCERS / SENSORS

Thermocouples and Thermocouple Wire T/C Temperature Type Range J 0 to 293°C (32 to 559°F) 293 to 750°C (559 to 1382°F) K 0 to 293°C (32 to 559°F) 293 to 1250°C (559 to 2282°F) E 0 to 340°C (32 to 644°F) 340 to 900°C (644 to 1652°F) T 0 to 133°C (32 to 270°F) 133 to 350°C (270 to 662°F) N 0 to 293°C (32 to 559°F) 0 to 1250°C (559 to 2282°F)

ORDERING INFORMATION


Pyromation Platinum RTD’s • • • •

Low and High temperature ranges 3 or 4 wire elements Accuracy exceeds DIN class B requirements Rugged 316 stainless sheath

These high accuracy platinum RTDs are built to DIN specifications, with α=0.00385 and accuracy of ±0.1% @ 0°C. Call for other resistance values or configurations To Order: Insert Code for Each Letter to Select Catalog Number Order Example PM/R1T185H483-12-00-15-T3-048-2 PM/ABCDE-F-G-H-I A

B

C

TRANSDUCERS / SENSORS

D

E

Temperature Range R1T185L Low-temp -200°C to 204°C R1T185H Hi-temp -200°C to 600°C Sheath Diameters 28 1/8” (0.125) 38 3/16” (0.188) 48 1/4” (0.250) 68 3/8” (0.375) RTD Element 3 3 wire 4 4 wire Sheath Length nn Two digit sheath length in inches

Vaisala Transmitters

F

G

H I

Re-Adjustable Compression Fitting 00 none 10B 1/4" NPT SS for 1/4", 3/8" sheath OD 10C 1/2" NPT SS for 3/16", 1/4" 11B 1/4" NPT Brass for 1/8", 3/16", 1/4", 3/8" 11C 1/2" NPT Brass for 1/4", 3/8" Leadwire Transition 15 Relief spring (400°F rating) 13 Same size transition Extension Leadwire T3 3 conductor teflon insulation T3A 3 conductor teflon insulation with stainless steel flex armor F3 3 conductor fiberglass insulation F3A 3 conductor fiberglass with flex stainless steel armor Leadwire Length nnn Lead length in inches using 3 digits Wire Terminations 2 Leads split 2" with 1/4" strip 3 Leads split 2" with spade lugs

NEW

CO2 Transmitters • • • •

Silicon-Based NDIR Sensor NEMA 4X enclosure Interchangeable Probes Easy Installation

• LCD Display Option • Analog Retransmit • Two Alarm/Relay Outputs

The GMT Series Transmitters measure CO2 in harsh and humid environments. A patented sensor provides outstanding time and temperature stability. The case is sealed and corrosion resistant. Choose from 10 measurement ranges: 2%, 3%, 5%, 10%, 20% full scale versions in the GMT221. 2000, 3000, 5000, 7000 or 10000 ppm versions in the GMT222.

Humidity Transmitter • Durable HUMICAP sensor • Fixed or remote probe • Quick-change probe • Optional LCD display • Full 0-100% RH measurement • NEMA 4X, IP65 case The HMT100 Series Transmitters are designed for humidity & temperature monitoring in demanding environments. The patented humidity sensor is resistant to dust & most chemicals. Single channel models transmit humidity or dewpoint. Dual channel models also transmit temperature. Measurement range is 0-100% RH, -40 to 80°C temperature, -20 to 80°C dew point temperature. Units with 4-20mA output(s) are loop powered. Voltage output models require an external 9-24VAC or 10-36VDC power supply.

113

SPECIFICATIONS Dimensions: Housing: Operating Temperature (transmitter without display): Probe Cable:

4.7 x 4.7 x 1.3" + 4" sensor or remote probe ABS plastic -40 to 60°C (HMT100), -20 to 60°C (GMT220)

Cable lengths to 39ft (10m) available


Vaisala Humidity & Temperature Transmitters • Measure humidity, temperature, dew point, mixing ratio, absolute humidity and wet bulb temperature • Small sensor head for use in tight spaces • Small sensor mass for fast response • Graphical display shows trends & 1 year history • Analog & alarm relay outputs • Corrosion resistant NEMA 4 (IP65) housing • Single point field calibration

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: HMT333 E0B201BCDC1B01AABC

HMT333 A

B

C

D

L

M

N

O

A

B

HMT333

L

The HMT333 Transmitter is a full featured front end for industrial and commercial humidity measurements. The HMT333 sensor provides accurate reading with excellent long-term stability, over the entire temperature range. The sensor is immune to particle contamination and most chemicals. A chemical purge to clean the sensor (via heating) can be initiated manually or at set intervals. Two analog outputs easily connect to meters, controllers, recorders and other equipment. The RS-232 interface simplifies setup and calibration. RS-485 & Ethernet options permit networking the HMT333 with other devices. Windows software is available to download and display the measurement data.

C D

E

F

Datalogger option records up to 4 years of data.

Optional:

Temperature Range: Accuracy at 20°C: Temperature dependence: Temperature sensor: RH Accuracy: 0-90 %RH: 90-100 %RH: Response time: Accuracy of analog output: External loads: Current outputs: 0-1V output: 0-5V & 0-10V outputs: Power consumption @24VDC: Operating temperature: with local display: Keypad: Display menus: Alarm relays: RS 485/422 interface: Dimensions: Housing: Probe:

Relative Humidity (RH) Temperature (T) Dewpoint Temperature (Td) Absolute Humidity g/m3 (a) Wet Bulb Temperature (Tw) Mixing Ratio g/Kg (x) Enthalpy (h) -40 to 80°C (176 °F) ±0.2°C ±0.0025°C/°C Pt100 class B ±2% RH ±1.7% RH 8 sec. in still air ±0.05% full scale <500Ω >2kΩ >10kΩ 110mA max, 220ma during purge -40 to 60°C (-40 to 140°F) 0 to 60°C (32 to 140°F) Sealed pushbuttons English, Spanish, French, German, 0.5A@250VAC, SPDT Full or half duplex, 9600 baud

G H I

J K

L M

N

7.2x4.7x3.0" (183x119x77mm) 3.5" x 0.5"dia (89x 12mm) O

Additional HMT330 models available for high temperature (180°C), high pressure, vacuum, high humidity and other applications. Also available: HMT360 Series Intrinsically Safe Transmitters.

F

G

H

I

J

K

Cable Length E0 2m (6.5ft) F0 5m (16.3ft) G0 10m (32.5ft) Transmitter Type A RH+T B RH+T+Td+Tdf+a+Tw+x+ppm+pw+pws+h+dT Display 0 No display 1 Graphic LCD with keypad Power Supply, Alarm Output 0 10-35 VDC, 24 VAC 1 10-35 VDC, 24 VAC isolated 3 100-240 VAC with 115V cord Analog Output Level 1 4-20 mA 2 0-20 mA 3 0-1 V 4 0-5 V 5 0-10 V Analog Output Signal (3 digits: Ch1, Ch2, Ch3) B RH 0 to 100%RH C T D Td -20 to +100 °C (-4 to +212 °F) E Tdf -20 to +100 °C (-4 to +212 °F) F a 0 to 600 g/m3 (0 to +262 gr/ft3) G Tw 0 to +100 °C (32 to 212 °F) H x 0 to 500 g/kg d.a. (0 to 3500 gr/lb d.a.) J h -40 to 1500 kJ/ kg (-17.2 to 644.9 Btu/lb) K ppm 0 to 5000 L pw 0 to 1000 hPa (0 to 14.5 psi) M pws 0 to 1000 hPa (0 to 14.5 psi) N dT -10 to 50 °C (14 to 122 °F) Analog Output Range for Temperature C -40 to +80 °C (-40 to +176 °F) D -40 to +120°C (-40 to +248°F) Output Units 1 Metric 2 Non-metric Options (2 Digits: Slot 1, Slot 2) 1 Relay Output 2 RS-485 4 Ethernet (requires external power) 6 Datalogger 0 None Cable Fitting A Cable gland M20*1.5 1 B /2 NPT conduit fitting Mounting 0 Normal 1 Wall plate 4 DIN rail Humidity Sensor 1 General purpose, Humicap180 2 with sensor purge, Humicap180C Sensor Protection A PPS grid & stainless steel netting (14 microns) B PPS plastic grid C Sintered stainless filter Installation Kit AB None BB Duct PC Accessories A None B Serial cable C Software & cable

114

TRANSDUCERS / SENSORS

SPECIFICATIONS Parameters: Standard:

E


Kobold Digital Temperature Sensor Programmable Features • Lockout Code • Dampening • Transmitter Span

L

• Measuring Range -58 to 250°F • Semiconductor Sensor • Scalable 4-20mA Output • Easy-to-Read LED Display • All Stainless Steel Construction

SPECIFICATIONS Display Type: Display Resolution: Accuracy:

TRANSDUCERS / SENSORS

Pressure: Process Temp: Ambient Temp: Material: Remote Probe Cable: Power: Output: Sample Rate: Dampening: Electrical Connection: Electrical Protection:

ORDERING INFORMATION

TDA

3-digit red LED 0.5° from -10° to +100°, 1° below -10 and above 100° 14 to 185°F: ±0.9°F 14 to -58°F: ±3.6°F 185 to 250°F: ±3.6°F 1150 PSIG max. 250°F max. 120°F max. 316L Stainless Steel housing & probe Teflon, 8ft. std. 24 VDC ±20% @ 20 mA 4-20 mA, 3-wire, 500Ω max. load 0.5 Sec./sample Averaging 2, 4,8, 16, 32, or 64 samples 4-Pin Micro-DC male plug or PVC jacketed cable NEMA 4/IP 65

To Order: Insert Code for Each Letter to Select Catalog Number TDA -15 – A – B – C – D A

B

C

D

Process Connection N4 1/2" NPT N5 3/4" NPT R4 1/2" BSP R5 3/4" BSP D6 Remote Probe (Smooth Shank) Measuring Range F2 0 to 250°F F3 -58 to 250°F (only available with Remote Probe) H2 -20 to 120°C H3 -50 to 125°C (only available with Remote Probe) Probe Length 0 12mm / 1/2" (not Available with Remote Probe) 1 100mm / 4" 2 185mm / 7.25" (not Available with Remote Probe) Electrical Connection L3M Micro-DC plug, 4-Pin male L3P 3 Ft. PVC cable L3S Custom length PVC cable

Kobold Magneto-Inductive Flowmeters

L

• Flow Rates from 0.26 GPM to 200 GPM • Use with Conductive Liquids, Acids & Caustic • No Moving Parts • Digital Display Option • Frequency or mA Output MIK-C34

Conductivity >30 µS/cm ±2.0% of full scale ±1% of full scale Requires 3X dia. upstream, 2X downstream 32–176°F (140°F max. with PVC fittings) 145 PSIG max @ 70°F 3.6 PSI max @ 100% rated flow NEMA 4X/IP 65 24 VDC ±20% required Micro-DC male, 4-pin (5-pin on C34) PNP open collector, 200 mA max. 4–20 mA, 3-wire, 500Ω max. PNP or NPN open collector, 300 mA max.

Compact electronic units (C34 Output Type) have a digital display and programmable switch setpoint, reset point, switch logic, 4–20 mA span/zero, dampening & lockout code. Set via 2-button keypad. Models with Integral Totalizer & Batch Controller electronics are also available.

NEW

ORDERING INFORMATION MIKA

B

SPECIFICATIONS Liquid: Accuracy: Repeatability: Straight Pipe: Operating Temp.: Pressure: Pressure Drop: Electrical Protection: Power Supply: Connector: Frequency Output Analog Output Switch Output

Example TDA-15-N4-F2-0-L3M

C

D

A – B – C – D

Example MIK-5NAU4NL343

Body Mat er ial 5NA Ryton with Buna-N Seal, 316L Electrode 5VA Ryton with FKM Seal, 316L Electrode 6FC PVDF with FFKM Seal, Hastelloy C4 Electrode Range Fitting Set Size (") GPM N P M U1 0.013-0.26 1/4 1/2 -U2 0.04-0.8 U4 0.13-2.6 3/8 3/4 3/8 U5 0.2-4.0 U7 0.4-8.0 1/2 1 1/2 U8 0.65-13 UA 0.8-16 1 -1 UB 1.3-26 UD 2.0-40 1-1/2 -1-1/2 UE 4.0-80 UG 6.5-130 2 -2 UH 10-200 Fitting Se t* N NPT female PVC P PVC hose barb M PVC glue socket A BSPP male Output F300 Frequency 0-500Hz F390 User Specified 50-1000Hz full scale L343 4-20mA C34N 4-20mA & NPN switch C34P 4-20mA & PNP switch

A 1/2 1/2 1 1-1/2 2 2-3/4

* PVDF butt weld tube & polypro NPT female fittings also available for some ranges.

115


Kobold Differential Pressure & Thermal Flow Sensors • 1-7 through 100-600 GPM Rates • Bronze or Stainless Housing • 4-20mA Process Output • Rugged 316 Stainless Steel Bellows The RCD series uses an orifice technique to generate a differential pressure which varies with flowrate but is unaffected by system pressure fluctuations. The single measuring bellows is coupled to a high accuracy hall effect detector.

SPECIFICATIONS Maximum Pressure: Maximum Temperature: Seals: Display: Output: Output Accuracy: Input Power: Optional Switch: Electronics Housing: Electrical Connection:

580 PSIG 176°F Buna-N 3 digit LED 4-20mA, 3 wire ±3% of full scale 24VDC ±20%, 80mA PNP or NPN open collector, 80mA max. 304 SS, NEMA 4x Micro-DC male, 5 pin

Temperature Independent Output 8 Segment LED Flow Rate Bar Optional Setpoint Relay Wide Viscosity Range No Moving Parts Extremely Low Pressure Loss NPT & Sanitary Fittings

The KAL-A uses the calorimetric principle to continuously monitor the flow of both viscous and non-viscous media. Flow rate is transmitted via a 4-20mA output, while an optional switch provides an alarm function. A single RTD element is used to both heat the probe tip and measure temperature. The internal microprocessor compensates for media temperature changes. An absence of protrusions prevents contaminants from building up on the probe tip.

SPECIFICATIONS Sensing Range Water: Oils (approx.): Response Time: Maximum Pressure:

0.05 - 2 m/s 0.1 - 4 m/s 5.6s typ. 1450 PSIG (Sanitary 600 PSIG) Ambient Temperature: 0°F to 176°F CIP Temperature: 280°F Housing: NEMA 4 Nylon, Explosion Proof (Al) optional Output: 4-20mA, 3-wire into 500Ω max. Linearity: ±10% of full scale Zero Adjustment: 0-75% of range Span Adjustment: 25-100% of range Power: 24±2VDC, 300mA max Switch Option: Adjustment: by Potentiometer Output: PNP open collector, 24V, 400mA max. Status Indicator: Bi-colored LED

ORDERING INFORMATION KO/KAL-7215 KO/KAL-7315 KO/KAL-7320 KO/KAL-7340S

304 SS Sensor, 1/2" NPT fitting 316-Ti SS Sensor, 1/2"" NPT fitting 316-Ti SS Sensor, 3/4" NPT fitting 316-Ti SS Sensor, 1 1/2" Tri-Clamp fitting

OPTIONS -P PNP Switch -M12 6’ cable & Micro DC connector Also available with switch output in place of 4-20mA output.

116

TRANSDUCERS / SENSORS

ORDERING INFORMATION KO/RCD- ABCD Example KO/RCD-1105GN4C34P A Material 11 Bronze 12 Stainless Steel B Flow Rate & Fitting Size 05GN4 1-7.2 GPM, 1/2" NPT 10GN4 2-11.2 GPM, 1/2" NPT 15GN5 2-17.6 GPM, 3/4" NPT 20GN5 2.5-22.5 GPM, 3/4" NPT 25GN6 5-35 GPM, 1" NPT 30GN6 8-44.5 GPM, 1" NPT 35GN8 10-73 GPM, 1 1/2" NPT 40GN8 20-114 GPM, 1 1/2" NPT 45GN9 20-184 GPM, 2" NPT 50GN9 25-240 GPM, 2" NPT 55GNB 30-280 GPM, 3" NPT 60GNB 50-410 GPM, 3" NPT 65GNB 100-620 GPM, 3" NPT C Type C3 Compact Electronics D Output 4P 4-20mA and 1 PNP switch 4N 4-20mA and 1 NPN switch 0R 2 PNP switches 0M 2 NPN switches Options -C Calibrate for specific gravity other than water (<0.95 or >1.05) -V Calibrate for viscous liquids ( viscosity >10cSt) Gas flowmeters also available.

• • • • • • •


Kobold Target-Type Flow Sensor • • • • •

1.5-8 to 225-500 GPM Water, Bronze and Stainless Bodies Variety of Wetted Materials Line Sizes 3/8" to 3" NPT Compact LED display with switch and 4-20 mA flow transmitter

SPECIFICATIONS Flow Range, Liquids: Accuracy: Repeatability: Straight Pipe Required: Operating Temperature: Maximum Pressure: Wetted Materials: Bronze Versions: Stainless Versions: Programmable Functions:

Standard Ranges (specify bronze or stainless body): Fitting 3/8" NPT

GPM wat er 1.5-8 3-12.5 1.5-8 3-18 1.7-15 5-25 5-20 20-35 15-45 25-60 25-120 40-200 175-400 225-500

1/2" NPT 3/4" NPT 1" NPT 11/2" NPT 2" NPT 3" NPT

DPT-C

L

Input Power: Display: Switch Type: Switch Rating: Analog Output:

1.5-8 GPM through 225-500 GPM water ±3% of full scale ±1% of full scale Inlet: 10 X Diameter Outlet: 5 X Diameter -10 to 176°F 580 PSIG @ 70°F Bronze, 316-Ti stainless steel, buna-N, ceramic 316-Ti stainless steel, viton, ceramic Lockout code, switch logic, switch setpoint and hysteresis, dampening 24 VDC ±20%, 80 mA Max. 3 digit LED PNP open collector 300 mA Max. short circuit protected 4-20 mA, 3-wire, RL=500 Ohms Max.

Westcon Photoelectric Sensors TRANSDUCERS / SENSORS

• • • •

L

• Designed to

W7703

NEMA 6 / IP67 Visible Narrow Beam for Small Object Detection Input 10-30 VDC, Dual Output (PNP & NPN) Separate Power and Signal LEDs PICO Style Quick Disconnect or 6" Pig Tail Available

• Designed to NEMA 6 / IP67 • Background Suppression • Light-ON and Dark-ON

• Small footprint, M18 Compatible Housing • Visible Narrow Beam for Small

Operate (Switch Selectable) • Highly visible Power and Output LEDs • Small Object Detection • Maximum Sensing Distance: 4", 6" or 8"

• Easy Setup • Separate

Object Detection

W7706

SPECIFICATIONS OPERATION

Polarized Retroreflective (Model 3BR) Retroreflective or Diffuse (Model 3AR) DETECTION RANGE Up to 160 ft. (48.8m) - Retroreflective Up to 12" (30.5cm) - Diffuse OUTPUT Bi-Polar PNP/NPN RESPONSE TIME/ <2mS / >500Hz FREQUENCY VOLTAGE 10 to 30 VDC REQUIREMENTS

ORDERING INFORMATION 770 3AR

04 N 3 B QP

BASIC MODEL 3AR Retro-reflective/Diffuse 3BR Polarized OPERATION 04 Switch selectable (light on/dark on) POWER N 10 - 30 VDC BEAM TYPE 3 Laser OUTPUT B Bi-Polar (NPN & PNP) FEATURES QP Quick Disconnect Standard (PICO M8 4 Pin) K Special PT Pig Tail 6" standard (Micro 4 Pin)

117

Power and Signal LED’s • Retroreflective or Diffuse

L

SPECIFICATIONS

SPECIFICATIONS Polarized Retroreflective Retroreflective or Diffuse DETECTION RANGE Up to 160 ft. (48.8m)- Retroreflective Up to 12" (30.5cm)- Diffuse OUTPUT Bi-Polar PNP/NPN RESPONSE TIME/ <2mS / >500Hz FREQUENCY VOLTAGE 10 to 30 VDC REQUIREMENTS

ORDERING INFORMATION

ORDERING INFORMATION 04 N 3

L

OPERATION

OPERATION Convergent Beam DETECTION RANGE 4 in., 6 in., 8 in. (10.16, 15.2, 20.3cm) OUTPUT Bi-Polar PNP/NPN RESPONSE TIME/ <2mS / >500Hz FREQUENCY 10-30 VDC VOLTAGE REQUIREMENTS

770 6AD

W7708

B

BASIC MODEL 6AD Diffuse OPERATION 04 Switch selectable (light on/dark on) POWER N 10 - 30 VDC BEAM TYPE 3 Laser (Convergent) OUTPUT B Bi-Polar (NPN & PNP) FEATURES QP Quick Disconnect Standard (PICO M8 4 Pin) K Special

QP

770 8AR

04 N 3 B QP

BASIC MODEL 8AR Retroreflective 8BR Polarized Retroreflective OPERATION 04 On/Off POWER REQUIREMENTS N 10 - 30 VDC BEAM TYPE 3 Laser OUTPUT B Bi-Polar (NPN & PNP) FEATURES QP Quick Disconnect Standard (PICO M8 4 Pin) K Special PT Pig Tail 6 in. Standard (micro 4 pin)


ATC Westcon Tach Generators • Corrosion-Resistant • 15,000 Hour Running Time

MODEL 758 AC GENERATORS

• Watertight Housings (Optional) • Explosion-Proof—UL Listed (Type E)

SPECIFICATIONS OUTPUT Model 750: 6 VDC per 1000 RPM (5000 RPM max) Model 758: 10 VAC per 1000 Frequency Responsive Speed Ranges F86 Series: 500 RPM-20,000 RPM F44 Series: 500 RPM-40,000 RPM F25: 40,000 RPM-100,000 RPM

L

L

AB

A

L

J2/M2

L

L

K3

W/E

758-9901000 758-9901001

Type JB2 Type JBF2 Type JB5 Type JBF5

758-9905000 758-0133477-902 Type W 758-9905001 Type WF 758-0134030-901 Type E 758-9907000 Type EF 758-9911000 758-9908000

Type K3 Type K30

750-9903000 750-9905000

Type J2 Type J2R Type M2

Type W

750-9905002

Type E

750-9905001

750-9906000 750-9906002 750-9906001

Type KB3 Type KBF3 Type KB6

Type KBF6 Type KB30 Type KBF30

758-0136522-902 758-0134277-901 758-0134277-903 758-9910002 758-0133484-902 758-9910001 758-0131483-902

BEARINGLESS AC GENERATORS Type XF86 Type XPF86 Type GF86 Type GPF86

758-9989002 758-0077533 758-9912002 758-0300008

Type XF44 Type GF44 Type GP44

758-0088466 758-0049982 758-0084866

Monarch Speed Sensors ROS-W Optical (1 to 250,000 RPM). Remote Optical Sensor with visible Red LED light source and Green LED on-target indicator. Complete with mounting bracket and 8' cable. Operates up to 3 feet and 45° from reflective target. Stainless Steel Sensor .625" dia. By 2.9".

P5-11

L

P5-11 Proximity (1 to 60,000 RPM). Probe style inductive sensor for use up to .2 inches from a .5" metallic target. Can work with one pulse per revolution from bolt head, keyway, etc. Sensor Dimensions: M14X1 thread, 1.26" long.

ROS-W

L MT-190W

L

MT-190W Magnetic Sensor with Amplifier (1 to 100,000 RPM). Recommended for use with 60 tooth gear, .25" gap, .106" pole piece dia., Sensor Dimensions: 5/8 x 18 UNF thread, 2" long.

IRS-W Infrared (1 to 999,990 RPM). Infrared Sensor with 8' cable. Use without Reflective Tape at .5" sensing gap from target. Senses white to black contrasting marks or beam can be interrupted by solid objects. Dimensions: 0.625"DIA x 2.9"L.

L IRS-5W ORDERING INFORMATION ROS-W MT-190W P5-11 IRS-W Accessories T-5

Remote Optical Sensor Magnetic Sensor Proximity Sensor Infrared Sensor Reflective Tape (5' x 12⁄ ")

118

TRANSDUCERS / SENSORS

Type A 750-9901000 Type A140R 750-282799

KB3

Type AB Type ABF

MODEL 750 DC GENERATORS

L

L

JB2


Newport Load Cells Miniature Compression Load Cell SPECIFICATIONS

ORDERING INFORMATION Capacity (lb.) 0-25 0-50 0-100 0-250 0-500 0-1000 0-2000 0-5000 0-10,000 0-50,000

Excitation: Output: Accuracy Class: Material: Linearity: Hysteresis: Repeatability: Safe Overload:

Model Number LCGD-25 LCGD-50 LCGD-100 LCGD-250 LCGD-500 LCGD-1K LCGD-2K LCGD-5K LCGD-10K LCGD-50K

10 VAC/ DC 2 mV/ V nominal 0.25% Stainless Steel ±0.25% FSO ±0.20% FSO ±0.10% FSO 150% FSO

LCGD-500

▲ LCGD-50

Cantilever Beams

3 mV/ V ±0.0075 mV/ V 10 VDC (15 VDC max) 0.03% FSO 0%, 50%, 100%, 50%, 0% 0.03% FSO 0.02% FSO 0.02% FSO ±1% FSO 150% FSO Stainless Steel

Model LC501

ORDERING INFORMATION

SPECIFICATIONS Output: Excitation: Accuracy: Calibrated Air: Linearity: Hysteresis: Repeatability: Zero Balance: Safe Overload: Material:

• Tension/Compression • Load Button, Rod End and Base Plate Mounting Accessories

Accessories for LC501 Series Capacity (lb.) ±100 ±200 ±500 ±1000 ±2000 ±5000 ±10,000

Model Number LC501-100 LC501-200 LC501-500 LC501-1K LC501-2K LC501-5K LC501-10K

Load Button Model LBC-012 LBC-012 LBC-012 LBC-012 LBC-012 LBC-012 LBC-034

Rod End Model REC-012M REC-012M REC-012M REC-012M REC-012M REC-012M REC-034M

Base Plate Model BP-10 BP-10 BP-10 BP-15 BP-15 BP-15 BP-20

Low Profile Load Cells ORDERING INFORMATION Capacity (lb.) 0-50 0-100 0-250 0-500 0-1000 0-3000 0-5000 0-10,000 0-20,000 0-50,000

Compression Cable Style Connector Style Model No. Model No. LC401-50 LC411-50 LC401-100 LC411-100 LC401-250 LC411-250 LC401-500 LC411-500 LC401-1K LC411-1K LC401-3K LC411-3K LC401-5K LC411-5K LC401-10K LC411-10K LC401-20K LC411-20K LC401-50K LC411-50K

Tension/Compression Capacity ±50 ±100 ±500 ±1K ±3K ±5K ±10K ±20K ±30K ±50K

Model No. LCHD-50 LCHD-100 LCHD-500 LCHD-500 LCHD-3K LCHD-5K LCHD-10K LCHD-20K LCHD-30K LCHD-50K

▲ Model LC411

SPECIFICATIONS Output (FSO):

3 mV/ V ±0.25%

Excitation:

10 VDC (15 VDC max)

Calibrated at:

0%, 50%, 100%, 50%, 0%

Zero Balance:

±1% FSO

Safe Overload:

150% FSO

Linearity: Hysteresis: Repeatability:

≥3000 lb: <3000 lb: ≥3000 lb: <3000 lb:

Compression 0.10% FSO 0.13% FSO 0.10% FSO 0.12% FSO 0.05% FSO

Tension/Compression 0.10% FSO 0.10% FSO 0.08% FSO 0.08% FSO 0.03% FSO

118a


Hioki Chart Recorders 2 or 4 Channel Memory Recorder

SPECIFICATIONS

High-speed electronic recorders with powerful trigger functions. Use for low-speed/long-term continuous recording or capturing high-speed transients.

L

8807

ORDERING INFORMATION 2 Channel Memory Recorder 4 Channel Memory Recorder Detachable Printer (requires AC adapter) Analog Input Leads (1 channel, 1.5m, alligator clips) Clamp-on Probe 10-500A, 40Hz-3kHz 100-240V AC Adapter (50/60 Hz) for 8807/8 Rechargeable Battery (3 hour use) Carrying Case RS-2332 Cable (1.5m)

• 4/8 analog + 16 logic inputs • 6.4-inch color TFT liquid crystal display • 4M word memory • Built-in printer uses 110mm paper • RS-232, LAN & GPIB interfaces

8835

2 analog, isolated + 8 logic (8807-01) 4 analog, isolated + 8 logic (8808-01) Range: 10 mV to 100 V/division, 13 ranges (10 division f.s.) Max. Voltage: 450V differential, 450V common mode Accuracy, BW: ±0.5%, DC to 50 kHz ± 3 dB Input: 1MΩ, isolated BNC conncetor Trigger Source: Analog in, logic in, A-B, external, timer, manual, logical AND/OR Analog Trigger: Level, window, voltage drop, RMS level, waveform Functions Memory recorder, recorder, RMS & memory recorder (DC & 50/60 Hz only) Memory Time Axis: 200 µs to 5 minutes/division, 19 settings (1 division =80 samples) Memory Capacity: 256 k words/ch (using CH1) 128 k words/ch (using CH1 & CH2) Data storage: Type II PC card slot (for SRAM cards to 32 MB, flash ATA cards to 528 MB) Interfaces: RS-232C, PC card fax modem Display: 5.7-inch STN color LCD Printer Option: 112 mm (4.4 in) x 18 m (59.06 ft), thermal paper roll Other functions: DMM function (numeric display), Scaling, Parameter calculations, Cursor readout, etc. Power: AA batteries, AC adapter, rechargeable battery Dimensions: 8.0" x 6.7" x 2.1" (203x170x52mm) Supplied with AA batteries, shoulder belt & Waveform viewer software High Speed Memory Recorder • Up to 20M samples/second • Expandable to 64 channels • Large internal memory • 10.4-inch high resolution color TFT display

L

RECORDERS / DATA LOGGERS

4 or 8 Channel Memory Recorder

L

HI/8807-01 HI/8808-01 HI/8922 HI/9197 HI/9018-10 HI/9418-10 HI/9447 HI/9391 HI/9612

Input:

8860

SPECIFICATIONS

SPECIFICATIONS Measurement Range:

10 mV to 50 V/div., 12 ranges (10 div. f.s.) with 8936 Analog Input Frequency: DC to 400 kHz ± 3 dB (with 8936 Analog Input) Memory Time Axis: 100 µs to 5 minutes/division, 20 settings (1 division =100 samples); external sampling (500 kS/s, minimum sampling period 2 µs) Measurement Memory recorder, Recorder, Functions: RMS recorder (50/60 Hz or DC only) Memory Capacity 4 M words x 1 channel to 500 k words x 8 channels Data Storage: FD drive, Type III PC card slot (SRAM/flash ATA/hard disk card) Other Functions: FFT, waveform parameter calculations, memory segmentation, cursor readouts, etc Power: 100-120 V AC (50/60 Hz), 10-28 V DC using the 9439 DC Power Adapter Dimensions: 11.2" x 8.7" x 5.2" (285x220x132mm) Supplied with Power cord, Recording paper(1 roll), Dust cover, Roll paper attachment(2), PC card protector, Wave viewer software. Order input modules (voltage, temperature, FFT, strain, F/V, charge), input leads, probes, data storage & interface separately.

119

Measurement Range: Input Options:

5 mV to 20 V/division, 12 ranges (20 divisions f.s.) 2ch, 12-bit, 20MS/s; 2ch, 16-bit, 2MS/s; 1ch Voltage/RMS, 12-bit, 1MS/s; 16ch Voltage/TC Trigger Types: Level, window, period, glitch, slope, logic pattern, voltage drop, external Memory Time Axis: 5ms to 5min/div, 25 settings or external sampling Memory Resolution: 100 points/div; zoom X2, X10 Memory Capacity: 32M word, expandable to 1G word Data Storage: FD drive, MO drive, HDD drive, Type II PC card slot (flash ATA) External Interfaces: USB1.1, Ethernet 10/100T, GPIB, HTTP, FTP, SVGA monitor Other Functions: FFT, waveform comparison, waveform calculations, clock, memory backup, sync out Power: 100-240 VAC, 140VA (300VA with A4 printer option) Dimensions: 13.0" x 10.75" x 7.25" (330x273x185mm) Specify up to four input modules, memory, data storage, interface & printer options. Test Leads and Carrying Case available separately.


Amprobe Power Quality Recorder

L DM-4

• TRMS measurements on single phase (2 or 3 wire) and three phase (Y or delta) systems • Easy to setup and operate • Measures Volts, Amps, Watts, VARs, VA, PF, energy and peak demand • Records all parameters simultaneously • Captures voltage sags and surges • Records voltage spikes down to 100nsec

• Battery or line powered (50/60Hz) • Protected against unauthorized setup changes • User selectable data sampling rate • Manual or programmable recording start • Remote user interface for field data analysis • Extract data to PC (Windows) or PDA (Palm OS)

SPECIFICATIONS Includes carrying case, CTs, test leads, PC software & RS-232 cable, remote user interface with protective hard case & interface cable, instruction manual.

ORDERING INFORMATION AB/DM-4

Descr ip tion 1000A clamp CT, 2" internal diameter Standard CT (DM-CT-HTA): 5 - 1000A Optional small CT (DM-CT-100): 1 – 100A AC Voltage, including Sags and Surges 20 - 1000V Voltage Transients 200 - 6000Vpp, duration >100nS Harmonics (Voltage and Current) THD, DC and individual up to 51th Power Energy Peak Demand Power Factor (True and Displacement) Phase Sequence Selectable Fundamental Available Recording Time

DM-4 Power Quality Recorder with 1000A clamp-on CTs

Accessor ies AB/DM-CT-100 AB/USB AB/MTL-501

Function Supplied Current Transducer AC Current

100A Compact Clamp USB to RS-232 adapter Advanced Electrical Test Lead Kit

Working (W), Reactive (VAR) & Apparent (VA) Working (kWh), Reactive (VARh) & Apparent (VAh) kW 0.00 – 1.00 1-2-3 50/60 Hz Several hours to several years depending on setup

Accur acy Input accuracy: ±(2% Rdg + 2 LSD) ±(3% Rdg + 2 LSD) ±10% Rdg ±(5% Rdg + 2 LSD), DC to 25th harmonic ±(3.0% Rdg + 2 LSD) ±(3.0% Rdg + 2 LSD) ±(3.0% Rdg + 2 LSD) ±3%

NEW

Yokogawa Portable Data Logger

• 1 pulse and 2 digital logic inputs • 100msec to 1 hour sample interval • Ethernet, USB, RS232 & RS485 • Web server, FTP client and email functions

SPECIFICATIONS Input

L XL122 SP1 Kit includes mating screw terminal block, US power cord, rechargeable battery, protective rubber boot, carrying case, utility software & manual. Utility sof twar e for Windows XP displays data & waveforms, copies data, converts to CSV, saves settings & files. Accessor ies YE/90060 YE/93037 YE/94009 YE/91029 YE/91011 YE/93039 YE/XL900

Type K thermocouple, 48” length with mini-plug Carrying case Lithium ion battery, 2.4Ah, 7V Digital I/O cable, 3m RS232 cable to PC (9 pin) Stand for tilted desktop, wall or DIN rail mounting Datum-LOGGER PC data analysis software (WinXP)

Maximum Input Measurement Interval Data Storage Functions Display Screens Communication Operating Temperature Storage Temperature Size Weight Safety

Type Accur acy Resolution DCV: ±100/500mV, ±1/5/10/50V, 1-5V F.S. ±0.1% F.S. 10µV TC: K,E,J,T,L,U,N ±0.05% F.S. ±1°C 0.1°C TC: W,R,S,B ±0.05% F.S. ±2°C 1°C 3-wire RTD: Pt100, JPt100 ±0.05% F.S. ±0.5°C 0.1°C Pulse: Instantaneous value, integration, revolution Logic: Voltage, contact ±50V 100/200/500ms, 1/2/5/10/20/30s, 1/2/5/10/20/30/60min (8 ch max for 100ms) 16MB internal memory, External storage: Compact flash memory card (Type II), SD card, USB memory (copy function only) Alarm output (4ch), Trigger function (pre-trigger/triggerdelay), Calculation (inter-channel calculation, linear scaling,statistical operation), Average, Automatic Measurement Waveform, digital, bargraph, waveform + digital, alarm summary, log 10Base-T/100-BaseTX Ethernet (SMTP, HTTP, FTP, TCP/IP, SNTP protocols) USB 1.1 ( Windows XP) RS-232 @2.4-38.4kbps, RS-485 @2.4-115.2kbps half-duplex (ASCII or Modbus RTU protocols) 0 to 50°C, 5 to 85%RH (non-condensing) -20 to 60°C, <90%RH (non-condensing) 6.1" x 6.1" x 2.2" (155 x 155 x 55mm), without projecting parts or rubber boot 1.8 lbs (800g), without battery or rubber boot EN61010-1: Measurement Category I, Pollution degree 2, Rated transient 350Vp-p

ORDERING INFORMATION YE/XL121-D/SP1 YE/XL122-D/SP1 YE/XL124-D/SP1

8 channel Portable Data Station Kit. Plug-in screw terminal block accepts wires 16 channel Portable Data Station Kit. Plug-in screw terminal block accepts wires 16 channel Portable Data Station Kit. M3 screw terminal block accepts wires or lugs. [no RTD inputs]

120

RECORDERS / DATA LOGGERS

• 8 or 16 isolated analog input channels • Supports direct TC, RTD and DCV inputs • 16MB internal memory + flash card capability • Wide viewing angle 3.5" color LCD • Trigger and alarm functions


Hioki Strip Chart Recorders

Partlow Chart Recorder • 1 or 2 Trend Pen Versions (optional)

• Up to 2 Process or Limit Alarms for Each Pen • Simple Operation and Set-Up

L

• Universal Inputs and Power Supply

8206-10

RECORDERS / DATA LOGGERS

8205-10 SPECIFICATIONS Input: DC /AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories:

Voltage or current, 1 channel 0.1-500V f.s., 12 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 20Hz - 30kHz, ±3dB 20cm/minute to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads

8206-10 SPECIFICATIONS Input: AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories:

Voltage and current, 2 channels alternate recording 100/200/500V extended scale, 3 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 30Hz to 30kHz, ±3dB 60cm/hour to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads

ORDERING INFORMATION HK/8205-10 HK/8206-10 HK/9650 HK/9651 HK/9668 HK/9235 HK/9236-01

121

One Channel Micro HiCorder Two Channel Micro HiCorder Clamp-on Sensor, 100A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 500A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 1000A f.s., 40Hz-1kHz, 3m length Recording paper (15m, 10 rolls) Recording paper, Climate-resistant (15m, 10 rolls)

• Optional PC Configuration Port • RS-485 Communications Option • Two Year Warranty

L

• AC or DC voltage to 500V • AC current to 1000A • 1 or 2 channels • 5 paper speeds • View input level on analog LCD display

• NEMA 3 Standard (NEMA 4X Option)

MRC5000

SPECIFICATIONS Input Range:

TC: J, K, T, R, S RTD: 100Ω Platinum, 0.00385 Ω/Ω/°C Current DC: 0 to 20mA, 4 to 20mA Voltage DC: 0 to 25mV, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V 10” User-configured: 8 hr, 12 hr, 24 hr, 48 hr, 7 day 0.5% of chart span reference accuracy 90 –264VAC 50/60Hz. 18VA max. consumption 14” x 14” x 3.8” (355.6 x 355.6 x 96.5mm)

Chart Size: Chart Rotation: Recording Accuracy: Power Requirements: Dimensions (WxHxD):

ORDERING INFORMATION To Order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PA/51 110211 A

B

C

D

E

F

G

A Pen 1 PA/51 Recorder only PA/52 Recording Controller B Pen 2 0 None 1 Recorder only C Pen 1 Outputs 0 None 1 One Relay D Pen 2 Outputs 0 None 1 One Relay E Digital Communications 0 None 1 Configurator Port F Case 1 Standard-NEMA3 2 Door Lock G Voltage 1 Standard (90–264V AC) 3 Standard, with 24V DC Transmitter Power Supply H Option Suffix Blank None

H

PA/54

High/Low Limit

2 4

Recording Controller High/Low Limit

2

Two Relays

2

Two Relays

2 3

RS-485 Com (Modbus RTU) Configurator Port & RS-485 Com

3

NEMA 4X

5 7

Standard, with CE Approval Standard, with CE and Transmitter Power Supply

AA

Alarms and communications connectivity option One hundred 0-100°F, 24-hour charts are provided with each instrument.


Fuji Strip Chart Recorders ORDERING INFORMATION

• Inkjet printing technology without physical contact with the paper • Low-cost • Lightweight, durable, and trouble-free 100mm recorder

To Order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PHE1-X-Y-32-5Y-OEV

• Available in one- or two-channel continuous trace

A - B - C - D - E - F

• Continuous analog trending on the same axis

A

• Prints periodic data, scale line, alarm condition, burnout, and parameter data • Manufactured in an ISO 9001 Facility • Three-year warranty

B

PHE

C

SPECIFICATIONS Input Points: Input Signals:

Max. Allowable Input Voltage:

Recording Method: Recording Points: Chart Paper: Recording Cycle: Recording Accuracy: Chart Speed: Power Supply: Dimensions (WxHxD):

121a

1 or 2 continuous recording TC: B, R, S, K, E, J, T, N, W, L, U, PN RTD: Pt 100Ω DC Voltage: 50mV, 500mV, 5V, 50V range DC Current: 4 to 20mA, converted into voltage with 10Ω or 250Ω shunt resistor TC, RTD and DC Voltage: ±10V DC or less (50mV, 500mV range) DC Voltage Input: ±100V DC or less (5V, 50V range) Inkjet type, 3 colors 1 or 2 continuous Effective width: 100mm, Z-folding type, length–15.08m 2 sec. minimum (chart speed dependent) Indicating accuracy ±0.2% 10, 20, 24, 30, 50, 120, 200, 300, 400, 1000, 1200, 1500mm/hour, set from the keyboard 100 to 120 VAC or 200 to 240 VAC, 50/60Hz 5.67 x 5.67 x 6.89in. (144 x 144 x 175mm)

D

E

F

Recording Points PHE1 1 continuous recording point PHE2 2 continuous recording points Input Signal for Ch. 1 X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100Ω RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Input Signal for Ch. 2 Y None X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100Ω RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Power Supply 32 100V/120V AC, 50/60Hz 42 200V/240V AC, 50/60Hz Scale Range 5Y One channel 55 Two channels Alarm Output 0EV None 1EV 1-ch. recorder, 2-point/no external control AEV 1-ch. recorder, 2-point/with external control 2EV 2-ch. recorder, 4-point/no external control BEV 2-ch. recorder, 4-point/with external control


• Web-based visualization & configuration • 4, 8 or 12 universal 16-bit inputs • Up to 12 relay outputs • Channel visualization in up to 8 groups • USB memory stick data storage • Ethernet interface for configuration • RS-485 Modbus master/slave • Mathematical functions in realtime • IP 65 / NEMA 4X front

L VU3

J, K, T, R, S, E, N, B, L Pt100, Ni120 mV: 0-50, 10-50 V: 0-5, 1-5, 0-10, 2-10 mA: 0-20, 4-20

Math function option: up to 12 additional channels can be defined with general arithmetic calculations, logic operations, statistical functions, reporting functions & triggering of automatic sequences.

ORDERING INFORMATION To Order, Insert Code for Each Letter to Select Catalog Number. Example VU3-400-000-A0-0 VU3 - A - B - C - D

B

C

D

Inputs 400 4 channels 440 8 channels 444 12 channels Outputs 000 None A00 12 relays Transducer Power 00 None A0 12 supply outputs Special Functions 0 None 1 Batch report 2 Math functions 3 External channels

Model Temperature HK/3632-20

Range

Memory* Feature

-20 to 70.0°C

16k

HK/3633-20

-40 to 180.0°C

16k

Temperature & Humidity HK/3641-20 -40 to 85.0°C, 0-100.0% RH

16k

Current HK/3634-20 HK/3636-20

0-20.00mA DC 0-50.00/500.0A AC RMS

16k 32k

HK/3638-20

AC Leakage Current

32k

±500.0mVDC ±5.000VDC ±50.00VDC 0-600.0VAC RMS ±50.00mV/500.0mV/ 5.000V/50.00DC 9,999count/ interval 2000/20000/200000 lux

16k 16k 16k 32k 32k

Voltage HK/3635-24 HK/3635-25 HK/2635-26 HK/3637-20 HK/3645-20 HK/3639-20 HK/3640-20

32k 32k

Waterproof with built-in sensor External/internal sensor, waterproof Alternately record on two channels

2ch with optional clamp sensor 2ch with optional clamp-on sensor

Multi-range logger with preheat signal function Pulse Totalizer (1ch) Illumination (1ch)

*16k readings unit have record interval of 2/5/10/15/20/30 seconds, 1/2/5/10/15/20/30/60 minutes. Models with 32k readings also have a 1sec record interval.

SPECIFICATIONS Accuracy 3632-20: 3633-20: 3641-20: 3634-20: 3636-20: 3638-20: 3635-24/-25/-26: 3637-20: 3645-20: 3639-20: 3640-20:

±1.0°C, except ±0.5°C from 0-35.0°C ±0.5°C (0-35.0°C) ±0.5°C (0-35.0°C), ±5 % RH (at 25 °C) ±0.8% rdg ±5d ±1% rdg ±5d (main unit only) ±1% rdg ±5d (main unit only) ±0.8 % rdg ±5d ±1% rdg ±5d ±0.5% rdg ±5d ±1d ±4% rdg ±5d

Data Transfer: Power Supply: Dimensions: Environment:

500 data elements/second via infrared link 2 AAA batteries 2.24"W x 2.91"H x 0.77"D Indoors, 0°C to 50°C, <80% RH

The Communication Base is used to transfer data from a Data Logger to PC. It can collect data on up to 16 channels. Data from multiple Data Loggers that are installed in fixed positions can be collected and then transferred to a PC via RS-232 or USB for analysis and processing.

4 5 6 7

Batch + Math Batch + Ext channels Math + Ext channels Batch + Math + Ext ch

Settings that can be made through the main unit: recording interval, recording start/stop. Settings that can be made through the Communication Base: current time, recording interval, recording start time, recording method, comment. HK/3911-20 HK/3920-20

RS-232 Communications Base USB1.1 Communications Base

122

RECORDERS / DATA LOGGERS

Basic Accuracy T/C ±0.1% of span ±0.3°C RTD ±0.1% of span ±0.3°C DC ±0.1% of span ±1d Scan Rate 200ms minimum Outputs Relays 3A@250VAC, 0.1A@250VDC resistive Analog Six 0-20 or 4-20ma, 12-bit Communications (both included) Ethernet Modbus TCP RS-485 Modbus RTU Display 640x480 color TFT Memory 150Mb internal flash Temperature 0-55°C operating Power 100-240VAC, 50/60Hz Dimensions 5.375"H x 5.44"W x 7.0"D

A

• Miniature size • 16,000 or 32,000 reading storage • Data is retained even when the batteries are dead • Power saving function

3641-20

SPECIFICATIONS Inputs T/C RTD DC

Hioki Data Loggers

L

West Paperless Recorder NEW • 6.4" color TFT display


Hioki Portable Recorder

NEW SPECIFICATIONS

• Ideal for transient capture & long-period recording • Compact, easy to carry • 4.3" color LCD display • 2 analog & 4 logic inputs • Sample rates up to 1M/sec • Analog inputs isolated to 300V • Simple USB PC interface Wave application software displays & prints waveforms, converts data to CSV format. Includes report templates with figure annotation & comments. XP/Vista compatible. PRO Kit includes 8870-20, 2 pair alligator clip voltage leads, AC adapter, rechargeable battery, hard carrying case, 256M flash card, USB cable, Wave software.

Input Range Accuracy Bandwidth Trigger Trigger Mode Time Axis Record Length Record Time Sample Rate Pre-trigger Resolution Zoom Display Volts Display

2 isolated BNC, 300V max 10mV - 50V/div ±0.5% of full scale DC-50kHz (-3dB) Level, logic, manual, ext. Single, continuous 100ms - 5min/div 20-20000 div, 10 settings 2s to 69 days 1ms to 3s 0-100% of record length 1/100 div, both axis x2, x10; both axis 4.3" TFT color LCD, 480x272 4 digit, autoranging

Calculation Types Screen Capture PC Interface Battery AC Adapter DC Power Temperature Dimensions

12 bits x 2Mwords/ch 1GB flash card, Type1 4 simultaneous, saved to flash card Avg, peak, min/max, RMS, freq, period Saved to flash card USB 2.0 mini-B Rechargeable, 2 hr life with continuous use 100-240VAC, also charges battery 10-16VDC, 10W max 0-40°C operating, <80% RH 7x4x1.6" (176x101x41mm)

ACCESSORIES

ORDERING INFORMATION HK/8870-20PRO

Memory Expansion Calculations

Portable Memory Recorder Kit

HK/9018-50 HK/9132-10 HK/9320-01 HK/9321-01 HK/9322

Clamp-on Current Probe, 10-500A Clamp-on Current Probe, 20-1000A 4 Channel Logic Probe, 50V DC max. 4 Channel Logic Probe, 250V AC/DC max. 1000:1 Differential Probe, 1kVAC/2kVDC max.

RECORDERS / DATA LOGGERS

AEMC Voltage & Current Data Loggers

SDL Sentinel®

• 3 or 4 Channels • True RMS measurements • Low-cost, self-contained, portable • Differential three-phase voltage inputs • Integral flexible current probe • Programmable storage modes & rates • Records up to 480,000 points • 64 samples per cycle • Optically isolated USB 2.0 communication • Includes DataView® software for real time display, data storage, analysis & report generation

SPECIFICATIONS Sample Rate Storage Rate Record Modes Memory Capacity Communications Controls Indicators Protection Rating Dimensions

64 samples/cycle 250ms to 12 hours, programmable Stop when full, FIFO, XRM* 1MB, 480,000 readings Optically isolated USB 2.0 One button for on/off & start/stop Red, yellow & green status LEDs IP50, except BNC models 600V CAT III 6.73 x 4.76 x 2.17" (171 x 121 x 55mm)

* In XRM, each time the memory fills, every other of the oldest data samples is discarded to make room for new samples.

M MODEL

SDL V301

SDL A301

SDL A302

SDL A303

SDL A304

SDL A401

SDL A402

No. of Channels Input Termination

Three Recessed banana jacks AC/DC Volts 0 to 600VAC 0 to 850VDC

Three Hard-wired flexible CTs AC Amps —

Three Hard-wired flexible CTs AC Amps —

Three Hard-wired flexible CTs AC Amps —

Three Hard-wired flexible CTs AC Amps —

Four BNC

Four BNC

AC Amps —

AC/DC Amps —

15 to 3000A

5 to 1000A

15 to 3000A

0.1V ±0.25% of rdg±0.6V from 85-600V ±1.0% of rdg±0.6V from 5-85V Alkaline batteries

0.1A ±1% of rdg ±1.5A

0.25A ±1% of rdg ±1.5A

0.1A ±1% of rdg ±1.5A

0.25A ±1% of rdg ±1.5A

5 to 1000A or 15 to 3000A, sensor development 0.25A ±1% of rdg ±1.5A

Probe with voltage output req’d (order separately) Probe dependent Probe dependent

Alkaline batteries

Alkaline batteries

100 hours to 90 days Six color-coded leads, batteries,

100 hours to 45 days Three hard-wired flexible CTs, batteries

100 hours to 45 days Three hard-wired flexible CTs, batteries

AC power/ NiMH batteries Power ride through 10 hours Batteries, 120V wall charger

AE/2134.15

AE/2134.16

AC power/ NiMH batteries Power ride through 10 hours Three hard-wired flexible CTs, batteries, 120V wall charger AE/2134.18

AC Power/ NiMH batteries Power ride through 10 hours Batteries, 120V wall

AE/2134.10

AC power/ NiMH batteries Power ride through 10 hours Three hard-wired flexible CTs, batteries, 120V wall charger AE/2134.17

AE/2134.19

AE/2134.20

Input Type Voltage Range Current Range

Resolution Accuracy Power Source Battery Life Hardware Included

Catalog Number

123


NEW

AEMC Simple Logger® ll Data Loggers

MODEL Channels Input Connector Measurement Range Resolution Accuracy (50/60Hz)

Sample Rate Storage Rate CAT III Rating MODEL Channels

L101 One

L322

Resolution Accuracy (50/60Hz) Measurement Input Sample Rate Storage Rate CAT III Rating

L

L642

L111 L261 One One BNC Recessed banana jacks 0-1V AC (probe dependent) 0-1A AC (probe dependent) 0-600V AC/DC 0.1mV 0.1mA 0.1V 10-50mV: ±0.5% of Rdg ±1mV 10-50mA: ±0.5% of Rdg ±1mA 5-50V: ±0.5% of Rdg ±1V 50-1000mV: ±0.5% of Rdg ±0.5mV 50-1000mA: ±0.5% of Rdg ±0.5mV 50-600V: ±0.5% of Rdg ±0.5mV 64 samples/cycle Programmable from 125mS to 1 day 50V 300V

Current Channel Voltage Channel BNC Banana jacks 0 to 1VAC 0 to 600VAC/DC (use current probes with a voltage output) 0.1mA 0.1V 10-50mV: ±0.5% of Rdg ±1mV 5-50V: ±0.5% of Rdg ±1V 50-1000mV: ±0.5% of Rdg ±0.5mV 50-600V: ±0.5% of Rdg ±0.5V 5Vrms (±7.07V pk-pk max) 1000V 64 samples/cycle Programmable from 125mS to 1 day 600V

240,000 measurements (512KB) 15 minutes to 8 weeks, programmable using DataView® Start/Stop, FIFO and Extended Recording Mode (XRM™) USB 2.0 optically isolated 2 x 1.5V AA-cell Alkaline batteries 100 hrs to >45 days, depending on storage rate 5.38 x 2.75 x 1.28" (136 x 70 x 32mm) -10 to 50°C operating

ORDERING INFORMATION AE/2126.02 AE/2126.03 AE/2126.04 AE/2126.05 AE/2126.06 AE/2126.07 AE/2126.35 AE/2126.08 AE/2126.01

Simple Logger ® II Model L101 (TRMS, 0 to 1VAC, 1 channel) Simple Logger ® II Model L102 (TRMS, 0 to 1VAC, 2 channel) Simple Logger ® II Model L111 (TRMS, 0 to 1AAC, 1 channel) Simple Logger ® II Model L261 (TRMS, 0 to 600VAC/DC, 1 channel) Simple Logger ® II Model L322 (4-20mA DC) Simple Logger ® II Model L432 (±100mV,1V,10VDC, 2 channel) Simple Logger ® II Model L562 (TRMS Voltage & Current) Simple Logger ® II Model L642 (Thermocouple Temperature) Simple Logger® II Model CL601 (Clamp-On, TRMS Current, 0 to 600A, 1.65" jaw opening)

AE/1201.51 AE/2115.82 AE/1200.72 AE/1200.73 AE/2113.49 AE/ 2110.90 AE/2140.62

AC/DC Current Probe Model SL261 (10A@100mV/A, 100A@10mV/A, BNC) AC Current Probe Model MN261 (24A@100mV/A, 240A@10mV/A, BNC) AC Current Probe Model MR461 (60A@10mV/A, 600A@1mV/A, BNC) AC Current Probe Model MR561 (150A@10mV/A, 1500A@1mV/A, BNC) AC Current Probe Model SR661 (10A@100mV/A, 100A@10mV/A, 1000A@1mV/A, BNC) AC Current Probe Model JM861 (30A@10mV/A, 300A@1mV/A, 3000A@0.1mV/A, BNC) Test Lead Pair, 5 ft w alligator clips, 600V CAT IV, 15A

ACCESSORIES

MODEL Channels Input Connection Measurement Range J K T N E R S Resolution Accuracy Sample Rate Max. Storage Rate CAT III Rating

L322 L432 One Two Removeable screw term block ±20mA DC ±100mV/±1V/±10V 0.01mA 0.1mV/1mV/10mV ±0.25% of ±0.5% of Rdg ±1mV Rdg ±0.05mA

Max. 8 samples at storage interval 50V

L642 Two Mini TC °F (°C) -346 to +2192 (-210 to + 1200) -328 to +2501 (-200 to + 1372) -418 to +752 (-250 to + 400) -328 to +2372 (-200 to + 1300) -238 to 1742 (-150 to + 950) 32 to 3212 (0 to 1767) 32 to 3212 (0 to 1767) 0.1° C/F up to 1000° C/F, 1° above 1000° C/F 0.1% to 0.2% + 0.6° to 1°, depending on the range & T/C type 8 samples at storage interval Programmable from 5 sec to 1 day 50V

CLAMP-ON AC LOGGER Simply clamp-on and start recording, no exposed wires to connect. • 50/400/600A TRMS ranges • One button operation • Alarm function • 5 LED indicators display logger status • Optically isolated USB 2.0 output • Includes DataView® software for data storage, real-time display, analysis & report generation • 300V CAT IV, 600V CAT III

L

CL601

Each Simple Logger® II includes USB cable, Dataview CD, batteries & manual.

124

RECORDERS / DATA LOGGERS

SPECIFICATIONS Memory Recording Length Storage Modes Communication Power Battery Life Dimensions Temperature

L562

L102 Two

L562 Two

Input Connection Input Range*

L

Compact size, battery operated Easily installed, operational in seconds TRMS measurement for accuracy on distorted waveforms Programmable alarm setpoints & triggers 5 LED indicators display logger status Choice of data storage modes Stores >240k measurements in non-volatile memory DataView software displays & analyzes real-time data on a PC

L

• • • • • • • •


Extech Temperature & Humidity Dataloggers Thermocouple Datalogger

Chart Recorder

• Dual & differential temperature measurements • Time stamped datalogging • 7 thermocouple types • Pushbutton or timer triggering • 3 to 355 second sample rate • Large 41/2 digit backlit display • Min/Max/Avg or Min/Max with elapsed time

• Graphical & digital display • 49000 reading memory • Programmable resolution • Audible & visual alarms • Wall or benchtop mounting

EA15

L RH520

L

SPECIFICATIONS

SPECIFICATIONS Range: J K T E R S N

-200 to 1994°F -200 to 1999.9°F -200 to 752°F -200 to 1598°F 35 to 1999.9°F 35 to 1999.9°F -200 to 1999.9°F

Temperature RH Accuracy: Dimensions:

-150 to 1090°C -150 to 1370°C -150 to 400°C -150 to 870°C 2 to 1767°C 2 to 1767°C -150 to 1300°C

Supplied with 3' probe, stand, RS-232 cable, AA batteries & AC adapter.

Resolution: Basic Accuracy:

0.1° ±0.05% rdg (+1.5°F/+0.75°C) Types J,K,E,T,N ±0.05% rdg (+4°F/+2°C) Types R,S Dimensions: 6" x 2.8" x 1.5" (152x72x37mm) Supplied with 2 Type K probes, PC software, RS-232 cable, holster, case & AAA batteries. EX/EA15 EX/EA15-NIST

EasyView™ Temperature Datalogger EasyView™ Temperature Datalogger w/ NIST Certificate Type K General Purpose Temperature Probe Bead Wire Temperature Probe Soft Vinyl Pouch Carrying Case

Hygro-Thermometer Datalogger • Dual display of RH, temperature, dew point & wet bulb • Store up to 15,000 readings • Sample rates from 1 to 86000 seconds • Data hold, Relative & Min/Max • Programmable power off timer

L

RECORDERS / DATA LOGGERS

EX/871515 EX/872501-S EX/409996

EA25

EX/RH520 EX/RH520-NIST EX/SL123 EX/SL124

125

EasyView Hygro-Thermometer Datalogger EasyView Hygro-Thermometer Datalogger w/ NIST certificate

Humidity + Temperature Chart Recorder Humidity + Temperature Chart Recorder w/ NIST certificate AC Alarm Relay Module with 9' (3m) cable DC Alarm Relay Module with 9' (3m) cable

Datalogger Kits • Log temperature or temperature/humidity • Store 8000 readings for each parameter • Log data for days, weeks or months • Sample rates from 1sec to 2hrs • Start on schedule, immediate or magnetic trip • Program & download multiple modules from one docking station

L 42275

SPECIFICATIONS Temperature: Humidity: Accuracy:

Resolution: Battery: Module:

-40°F to 185°F (-40°C to 85°C) 0 to 100%RH ±1°F (-4 to 122°F), ±2°F (-40 to -4°F, 122 to 185°F) ±0.6°C (-20 to 50°C), ±1.2°C (-40 to 20°C, 51 to 85°C) ±5%RH 0.1°, 0.1% Lithium, 1 yr life 3" x 2.3" x 0.88" (76x57.2x22.3mm)

EX/42275 EX/42270 EX/42265 EX/42260

Temperature/Humidity Datalogger Kit Temperature/Humidity Datalogger Temperature Datalogger Kit Temperature Datalogger for 42265

SPECIFICATIONS Range: Dew Point -91.1 to 139.8°F (-68.4 to 59.9°C) Wet Bulb 21.7 to 140°F (-5.7 to 60.0°C) Temperature -4 to 122°F (-20 to 50°C) Humidity 0-95% RH Resolution: 0.1°, 0.1% Accuracy: ±0.9°F (±0.5°C), ±3% RH Dimensions: 6"x2"x1.4" (152x72x35mm) Supplied with probe, stand, protective cover, PC software, RS-232 cable, holster, case & AAA batteries. EX/EA25 EX/EA25-NIST

-20.0 to 140.0°F (-28.0 to 60.0°C) 10.0 to 95.0% ±1.8°F (±1°C), ±3% RH 5" x 7.7" x 0.9" (129x195x22mm)

Datalogger kits include docking station & software.


Extech Sound Meters Datalogging Sound Level Meter

L

• ANSI Type 2 meter with 16000 record memory • Large LCD with fast 50 segment bargraph • Time stamped data, Max Hold function • RS-232 & recorder outputs • Tripod mounting

407764

SPECIFICATIONS 30-130dB ±1.5dB A&C Fast, slow 10.4 x 2.8 x 0.8" (265x72x21mm)

ORDERING INFORMATION

• 1000A Clamp measures 1Ø & 3Ø power to 600kW • Display True Power, Apparent Power, Power Factor, True RMS Voltage & Current, Resistance and Frequency • Dual display of kW+PF, kVA+PF, V+A, A+Hz or V+Hz • Clamp jaws open to 1.8" (46mm) • Data Hold and Auto Power Off • Built-in recorder datalogs up to 4000 readings • 25 point data memory viewable on the LCD display • Full function display on large 4-digit LCD with fast 40 segment bargraph, Peak Hold and Min/MAX 382068 • CAT III-600V; CE • Includes 9V battery, alligator clips, test leads, case, RS-232 module, Windows compatible software and cable

L

Range: Basic Accuracy: Weighting: Response Time: Dimensions:

Extech Clamp-On Power Datalogger

Complete with microphone, wind cover, Windows software, serial cable, AA batteries & carrying case. EX/407764 EX/144117 EX/407764-EXT EX/407744 EX/407766

Datalogging Sound Level Meter 120V AC Adapter Microphone Extension Cable, 15ft (4.7m) 94dB Sound Calibrator 94/114dB Sound Calibrator

Sound Level Monitor

NEW

SPECIFICATIONS Frequency: Ranges: Resolution: Weighting: Response Time: Dimensions:

31.5Hz – 8kHz 30-80dB, 60-110dB, 80-130dB 0.1dB A&C Fast (125ms), Slow (1s) 8.75 x 7.1 x 1.25" (22x18x3.2mm)

True Power: Apparent Power: Peak Current: Peak Voltage: AC Current (40-500Hz): DC Current: AC Voltage (40-500Hz): DC Voltage: Frequency: Resistance: Continuity: Dimensions/ Weight:

ORDERING INFORMATION EX/382068

EX/382068-NIST

EX/480172

ORDERING INFORMATION

Clamp-on Power Datalogger kit with software Clamp-on Power Datalogger kit with software & NIST certificate AC Line Splitter, 3-prong plug with x1 & x10 postions, live voltage indicator

L

Complete with swivel microphone, wind cover, AA batteries EX/SL130G Sound Level Monitor with 110V AC Adapter EX/SL125 Microphone Extension Cable, 15ft (4.7m) EX/SL123 AC Alarm Relay Module, 9ft cable EX/SL124 DC Alarm Relay Module, 9ft cable EX/TR100 Tripod

Range Resolution Basic Accuracy 600kW 10W ±(2%rdg+5d) 1000kVA 10VA ±(2%rdg+5d) 1000A 0.1A ±(6%rdg+10d) 600V 0.1A ±(6%rdg+10d) 1000A 0.1A ±(1.5%rdg+5d) 1000A 0.1A ±(1.5%rdg+5d) 600V 100mV ±(0.5%rdg+5d) 600V 100mV ±(0.5%rdg+5d) 5kHz 0.1Hz ±(0.5%rdg+5d) 10kΩ 1Ω ±(1%rdg+5d) Beeper when <50Ω 10.2x3.7x1.8" (260x93x45mm)/ 15.9oz (450g)

480172

126

RECORDERS / DATA LOGGERS

L

• Extra large display with bargraph • Adjustable high or low limit • OVER display • External alarm output • Time stamped Max reading memory • Meets ANSI Type 2 SL130 • Wall, bench or tripod mounting

SPECIFICATIONS


Extech Thermal Imagers NEW Simpson Elapsed Time Meters L

Affordable i5 InfraRed Camera

112ET

L

Pocket sized and fully automatic 2% accuracy, 0.1°C sensitivity Large 2.8" color LCD i5 80 x 80 pixel image >4 hour continuous operation IP43 dust/splashproof housing MiniSD™ card stores up to 5000 images

109ET

L

L

• • • • • • •

2153ET

Battery Charging System AC Operation Operating Temp Dimensions Weight

MISC.

Complete with 512MB miniSD™ Card, Li-Ion rechargeable battery, 100-260V AC adaptor/charger, QuickReport™ software, USB Mini-B cable, built-in manual lens shutter, and hand strap.

Deluxe InfraCam™ SD Thermal Camera

L

• 14 to 662°F (-10 to 350°C) temperature range • 3.5" (89mm) color LCD • 120 x 120 pixel image resolution • IP54 dust/splashproof housing • Built-in laser pointer • Removable 128MB SD Memory Card (1000 images) • Rechargeable 7 hour battery IRC57

ORDERING INFORMATION EX/IRC40 EX/IRC57

127

EXTECH i5 Thermal Imaging Infrared Camera InfraCAM™ SD Thermal Imaging InfraRed Camera

55ET

L

Spectral range Display Image Controls Set-up Controls Measurement Modes

32-482°F (0-250°C) 5000 images (mini SD card memory) Emissivity table; 0.1 to 1.0 adjustable 17° x 17° 0.6m (2 ft.) min., focus free Focal plane array (FPA) uncooled microbolometer 7.5 to 13µm 2.8" color LCD Palettes (Iron, Rainbow, and Black/White) Date/time, °C/°F, 21 languages Spot (corrected for emissivity and reflected temperature) 4 hour Li-ion, rechargeable In camera, AC adapter; 3 hours to 90% capacity AC adaptor 90-260VAC, 50/60Hz 32-122°F (0-50°C), 20-80% RH, non-condensing 8.8x3.1x3.3" (223x79x83mm) <12oz. (340g), including battery

57ET

L

Temperature Range Image Storage Emissivity Field of View Focus Distance Detector Type

L

SPECIFICATIONS

1357ET

• 6 Digit Readout • No Reset Capability (Virtually Tamper-proof) • Six Case Styles • 11/2" and 31/2" sizes • AC and DC Models • Phenolic cases with glass windows Accumulate running time and monitor life of AC or DC powered equipment. Synchronous motor provides accurate hour indication (to 99,999.9 hours). Connect in parallel with the equipment being monitored.

ORDERING INFORMATION Model

Size

Catalog #

Voltage

109ET

11/2"

SI/03618

10-80 VDC

112ET

11/2"

SI/03622

120 VAC

55ET

31/2"

SI/03580

120 VAC

57ET

31/2"

SI/03590

120 VAC

1357ET

31/2"

SI/03595

120 VAC

2153ET

31/2"

SI/17720

120 VAC

55ET

31/2"

SI/03600

240 VAC

57ET

31/2"

SI/03610

240 VAC

1357ET

31/2"

SI/03615

240 VAC

2153ET

31/2"

SI/17721

240 VAC


Yokogawa AC Elapsed Time Meters • Meets ANSI C-39.1 • Five Case Styles • Wide Selection of Ranges

• Weather Resistance • UL Recognized

SPECIFICATIONS Accuracy Vibration Shock Materials Presentation Insulation Level Motor

Matches frequency control of power system Meets ANSI Specification C39.1 Case of clear LEXAN®, frame of Noryl®, brass terminal studs, Lucite® front covers 6-digit counter in hours and tenths of hours or minutes and tenths of minutes Operating at 120, 208, 240 or 480 volts AC, will pass Hi-pot of 2000 VRMS for one minute 3 Watts typical

Round Case

ORDERING INFORMATION Insert:

31⁄2" Size 24031 1 24031 1 24031 1 24031 1 24031 1

AAAB ADAB ABAB AEAB ACAB

24071 24071 24071 24071 24071

1

AAAD ADAD ABAD AEAD ACAD

24073 24073 24073 24073 24073

1

1 1 1 1

1 1 1 1

• Reset & Non-Reset Versions

L Switchboard Case

L

AAAE ADAE ABAE AEAE ACAE

Square Case

L

* NOTE: Conduit mount available in non-reset versions ONLY.

Back of Panel Unmounted

Yokogawa Hour Meters • ANSI Switchboard Case • UL recognized

New Big Look Panel Mounted

MISC.

1 - for Register in Hours and Nonresetable 2 - for Register in Hours and Resetable 3 - for Register in Minutes and Nonresetable 4 - for Register in Minutes and Resetable AC Elapsed Time Meters-Type 240 Big Look Voltage/Freq. 21⁄2" Size 120V-60 Hz 24021 1 AAAB 120V-50 Hz 24021 1 ADAB 208/240V-60 Hz 24021 1 ABAB 208/240V-50 Hz 24021 1 AEAB 480V-60 Hz 24021 1 ACAB AC Elapsed Time Meters-Type 240 Square Case 120V-60 Hz 24061 1 AAAD 120V-50 Hz 24061 1 ADAD 208/240V-60 Hz 24061 1 ABAD 208/240V-50 Hz 24061 1 AEAD 480V-60 Hz 24061 1 ACAD AC Elapsed Time Meters-Type 240 Round Case 120V-60 Hz 24063 1 AAAE 120V-50 Hz 24063 1 ADAE 208/240V-60 Hz 24063 1 ABAE 208/240V-50 Hz 24063 1 AEAE 480V-60 Hz 24063 1 ACAE AC Elapsed Time Meters-Type 240 Back of Panel (One Size Only) Voltage/Freq. Catalog No. 120V-60 Hz 24000 1 AAAA 120V-50 Hz 24000 1 ADAA 208/240V-60 Hz 24000 1 ABAA 208/240V-50 Hz 24000 1 AEAA 480V-60 Hz 24000 1 ACAA AC Elapsed Time Meters-Conduit Mounted Case and 21⁄2" Round Meter* Voltage/Freq. Catalog No. 120V-60 Hz 24025 1 AAAF 208/240V-60 Hz 24025 1 ABAF 480V-60 Hz 24025 1 ACAF 1

L

L

ORDERING INFORMATION SPECIFICATIONS

Readout: Material: Vibration/Shock: Motor: Bezel: Depth:

99,999.9 hours. Steel case, polycarbonate cover ANSI C39.1 3W synchronous 4.33" square 4.3" behind panel

Reset requires removal of front cover.

Voltage/Freq. 120V-60Hz 120V-50Hz 208V-60Hz 208V-50Hz 240V-60Hz 240V-50Hz 480V-60Hz 480V-50Hz

Non–Reset 103811 AAAB 103811 ADAB 103811 AGAB 103811 AHAB 103811 ABAB 103811 AEAB 103811 ACAB 103811 AFAB

Reset 103822 AAAB 103822 ADAB 103822 AGAB 103822 AHAB 103822 ABAB 103822 AEAB 103822 ACAB 103822 AFAB

128


ENM Hour Meters & Counters • • • • •

6 digit LCD Display Non-volatile Memory Up/down Counting Resettable Shock Resistant

SPECIFICATIONS Display:

Digit Height: Power: Count Speed: Terminals: Temperature:

99999.9 (hour meter) 0 to 999999 (up counter) 999999 to 0 (down counter) 5mm 8-28VDC 100/second max. 3/16" male quick connects -40 to 85°C

L

Electronic LCD Hour Meter/Counter

T1121A

ORDERING INFO Example T1121AB A Type T C D B Style 1121A 1131A 1141A C Finish B S

Timer Up Counter Down Counter Screw Mount Clip Mount Rectangular Clip Mount Black Stainless T1131A

• • • •

L

Hour Meter & Battery Discharge Gauge

L

T1141A

6 Digit LCD Hour Display 10 Segment LED Battery Charge Indicator Fits 2" Diameter Hole -10 to 65°C Temperature Range

ORDERING INFO Voltage 12/24VDC 24/36VDC 36/48VDC 70/80VDC

L

Model PT271AB1 PT272AB1 PT273AB1 PT274AB

T51D

MISC.

PT271AB1

L L

Electromechanical Hour Meters • • • • • •

Low Power Consumption Solid State Drive Circuit Mechanical Indicator Retains Reading Quartz Crystal Timing Quiet Operation Sealed, Tamperproof Plastic Case

SPECIFICATIONS Display: Digit Height: Temperature: Terminals:

129

99999.9 hours, auto recycle to zero 0.125" -30 to 65°C 1/4" male quick connects

T41E

ORDERING INFO Example T51D4 A Type T41 T51 B Style D E F C Power 1 2 4 45

DC powered hour meter AC powered hour meter Front panel mount (clips) Back of panel mount (screw holes) 48x48mm panel mount (clips) 230VAC 50/60Hz 115VAC 50/60Hz 24VAC 50/60Hz 10-80VDC

T41F

L


ATS Large Digital Displays • Run Time Accumulators • Analog Input Displays • Production Monitors • Counters • GPS Clock Systems • Timers

L AE46S–373

L AE2412

BRIGHT RUN TIME ACCUMULATORS AT/AE24-373 2.3 Inch, Four Digit, MM:SS AT/AE26-373 2.3 Inch, Six Digit, HH:MM:SS AT/AE44S-373 4 Inch, Six Digit, MM:SS AT/AE46S-373 4 Inch, Six Digit, HH:MM:SS Other sizes and configurations available

ANALOG INPUT DISPLAYS AT/AE24-341 AT/AE2412-341 AT/AE26-341 AT/AE24F-341 AT/AE2412F-341 AT/AE42S-341 AT/AE43S-341 AT/AE44S-341 AT/AE45S-341 AT/AE46S-341 Four Digit Resolution

2.3 Inch, Four Digit, 4-20 mA 2.3 & 1 Inch, Six Digit, 0-5VDC 2.3 Inch, Six Digit, 0-10VDC 2.3 Inch, Four Digit, Flush Mount 2.3 & 1 Inch, Six Digit, Flush Mt. 4 Inch, Two Digit, 4-20mA 4 Inch, Three Digit, 0-5VDC 4 Inch, Four Digit, 0-10VDC 4 Inch, Five Digit, 4-20mA 4 Inch, Six Digit, 0-10VDC

PRECISION TIMERS

POWER OPTIONS 12VAC 12V3 24VAC 220V1 PC8

12 VAC, 60HZ 12 VDC to 15 VDC 24 VAC, 60 Hz, 5VA 220 VAC, 60 Hz, 12.6 VA Add 120 VAC Power Cord, 8’ long

L AE44–503

Large Bright Red LED Displays with digit sizes from 1” to 12” high. Visible from 25 feet to 500 feet. Display temperature, pressure, flow and other process variables. Accumulate machine cycle time, run time or downtime. Monitor production counts. Synchronized clock systems with GPS accuracy. Count-up or countdown elapsed time. Custom units available. SYNCHRONIZED CLOCK SYSTEMS AT/MC4181LV

Master Clock to synchronize Clocks, Bells, Time & Attendance System with Computer AT/GPS-TR3 GPS Master Clock Interface, includes Antenna/Receiver and Interface. AT/CC2002 Four digit, four inch red LED Clock Single sided, wall mount, 24 VAC AT/CC2002W2 Four digit, four inch red LED Clock Double sided, wall mount, 24 VAC AT/CC2002C2 Four digit, four inch red LED Clock Double sided, ceiling mt, 24 VAC AT/CC2002 Four digit, four inch red LED Clock Single sided, flush mount, 24 VAC AT/8901–1821 24VAC, 200VA, (8 Amp) Power Supply. 12” x 12” x 4”

COUNTER OPTION OPT-230 Input signals:

Event Counter (To 25Hz Speed) 12-120V AC or DC, >20ms duration

PRODUCTION MONITORS AT/AE44-503J AT/AE44-503C AT/AE-503DX1

Monitor GOAL and ACTUAL counts Two lines of four digits, four inch Designed for use with Remote Controller. Controller for AE44-503C above

ENCLOSURE OPTIONS OPT-N12A OPT-N12B OPT-N4XA

NEMA 12 rated, 16”W x 8”H x 6”D NEMA 12 rated, 24”W x 8”H x 6”D NEMA 4X rated Stainless Steel, 16”W x 8”H x 6”D OPT-N4XB NEMA 4X rated Stainless Steel 24”W x 8”H x 6”D NEMA enclosures available on selected models

DIGIT SIZE 2.3" 4" 8" 12"

VIEWING DISTANCE Typical 70 ft 120 ft 240 ft 360 ft

Maximum 110 ft 200 ft 400 ft 600 ft

130

MISC.

AT/STD-11-2 Measure & Display Accurate Elapsed Time: 0.000 – 9999.999 Seconds AT/STD-525T Measure Accurate Elapsed Time Minutes, Seconds, Tenths and Hundredths of seconds AT/2171-2 Handheld Pendant Control

L STD–525


Crompton Protector Trip Relays • Phase Loss, Reversal or Sequence • Under and Over Current or Voltage Protection • Load Detection • Monitoring of Systems The Crompton Protectors provide continuous surveillance of the monitored circuit. When the current moves outside the set point limit, the relay operates. An illuminated LED indicates when the relay is energized. For 3 phase systems, the sequence of connection is not important. Standard overcurrent relays will energize on trip when the nominal input current plus the user adjustable “over nominal value” is exceeded, after the preset additional delay period if set. The relay will automatically reset to de-energize when the input current is lowered past the setpoint minus the hysteresis (differential) value.

L 252-PHU

Standard undercurrent relays will de-energize on trip when the input current is below the nominal value minus the user adjustable “under nominal value” after the preset additional delay period if set. The relay will automatically reset to energize when the input current is raised past the setpoint plus the hysteresis value. On request, any product can be manufactured with the energize/de-energize functions reversed.

MISC.

ORDERING INFORMATION System Input Aux. Power Protection AC Current (Adjustable time delay 0-10 sec., fixed hysteresis 1%) Single Phase 5A 120V Under current 40-120% Single Phase 5A 120V Over current 40-120% Single Phase 5A 120V Under & over current 3 Phase 3 or 4 Wire 5A 120V Under current 3 Phase 3 or 4 Wire 5A 120V Over current System Protection AC Voltage (Adjustable hysteresis 1-15%) Single Phase L-N Under Voltage 75-100% Over Voltage 100-125% Over and Under Voltage 3 Phase, 3 Wire L-L Under Voltage 75-100% Over Voltage 100-12% Over and Under Voltage 3 Phase, 4 Wire L-N Under Voltage 75-100% Over Voltage 100-12% Over and Under Voltage AC Voltage (Adjustable time delay 0-10 sec., fixed hysteresis 1%) Single Phase L-N Under Voltage 75-100% Single Phase L-N Over Voltage 100-12% 3 Phase, 3 Wire L-L Under Voltage 75-100% 3 Phase, 3 Wire L-L Over Voltage 100-12% 3 Phase, 4 Wire L-N Under Voltage 75-100% 3 Phase, 4 Wire L-N Over Voltage 100-12% System Input Protection Frequency (Adjustable hysteresis 0.1-3.0Hz) Single Phase 120 VAC Under Frequency 55-65 Hz Single Phase 120 VAC Over Frequency 55-65 Hz Single Phase 120 VAC Under & Over (2 output relays) Combined Under/Over Voltage and Under/Over Frequency Single Phase 120V / 60 Hz Over & Under Voltage Over & Under Frequency (50-70 Hz) (4 Independent Double Pole change over relays)

131

Catalog Number 252-PAUU-LSBX-C6-DG-D1-EB 252-PAOU-LSBX-C6-DG-D1-EA 253-PADU-LSBX-C6-DG-D1-EC 253-PAVU-LSBX-C6-DG-D1-EB 253-PAPU-LSBX-C6-DG-D1-EA Catalog Number 252-PVUU-PQBX-C6-EB 252-PVOU-PQBX-C6-EA 253-PVBU-PQBX-C6-EC 252-PVKU-PQBX-C6-EB 252-PVAU-PQBX-C6-EA 253-PVMU-PQBX-C6-EC 252-PVVU-PQBX-C6-EB 252-PVPU-PQBX-C6-EA 253-PVEU-PQBX-C6-EC 252-PVZU-PQBX-C6-EB-T1 252-PVHU-PQBX-C6-EA-T1 252-PVJU-PQBX-C6-EB-T1 252-PVCU-PQBX-C6-EA-T1 252-PVXU-PQBX-C6-EB-T1 252-PVSU-PQBX-C6-EA-T1 Catalog Number 252-PHUU-PQBX-C6-EB 252-PHOU-PQBX-C6-EA 253-PHDU-PQBX-C6-EC 256-PHUV-PQBX-C6

L 252-PVR


Crompton Protector Trip Relays ORDERING INFORMATION Input

Protection

120V L-L 60 Hz

Phase Sequence, Under Voltage

120V L-L 60 Hz 480V L-L 60 Hz 120V L-L 60 Hz 480V L-L 60 Hz

Phase Loss & Unbalance Phase Loss & Unbalance Phase Loss, Unbalance, Under Voltage Phase Loss, Unbalance, Under Voltage

5A, 120V, 60 Hz 5A, 120V, 60 Hz 5A, 120V, 60 Hz 5A, 120V, 60 Hz Input 120V/60 Hz 120V/60 Hz Input 18-20V* 18-20V* 24V Input

Catalog Number

Reverse Power 2-20% Reverse Power 2-20% Reverse Power 2-20% Reverse Power 2-20% Protection BUS Phase Angle & Voltage Phase Angle & Voltage Protection

Live BUS Dead BUS

Under Voltage External Time Delay Under Voltage Differential 1-15% Over & Under Voltage (2 relays) Protection Aux Power

252-PVRU-PQBX-C6 252-PSFU-PQBX-C6 252-PSFU-SEBX-C6 252-PSGU-PQBX-C6-T1-1A 252-PSGU-SEBX-C6-T1-1A 256-PASU-LSBX-PQ-C6-EA 256-PATU-LSBX-PQ-C6-EA 256-PAQU-LSBX-PQ-C6-EA 256-PARU-LSBX-PQ-C6-EA Catalog Number 256-PLLU-PQBX-C6 256-PLDU-PQBX-C6 Catalog Number 252-PDUU-NABX-T1-EB 252-PDEU-NABX-EB 253-PDCU-BDBX-T1-EC-BD Catalog Number

50 mV 50 mV 100 mV 100 mV J,K,T,S,T J,K,T,S,T

High Trip Low Trip High Trip Low Trip High Trip Low Trip

120V 120V 120V 120V 120V 120V

252-PBTU-ECBX-DG-T1-EA 252-PBSU-ECBX-DG-T1-EA 252-PBTU-GBBX-DG-T1-EA 252-PBSU-GBBX-DG-T1-EA 252-PTOU-T*BX-DB-T1-EA 252-PTUU-T*BX-DB-T1-EB

1 mADC 1 mADC 1 mADC 4-20 mADC 4-20 mADC 4-20 mADC 10 VDC 10 VDC 10 VDC Protection

Low Trip 0-80% Hip Trip 40-120% Low/High, 2 relays Low Trip 0-80% Hip Trip 40-120% Low/High, 2 relays Low Trip 0-80% Hip Trip 40-120% Low/High, 2 relays DC Aux. Power

120V 120V 120V 120V 120V 120V 120V 120V 120V

252-PBAU-FABX-DG-T1-EB 252-PBBU-FABX-DG-T1-EA 252-PBVU-FABX-DG-T1-EC 252-PBAU-HGBX-DG-T1-EB 252-PBBU-HGBX-DG-T1-EA 252-PBVU-HGBX-DG-T1-EC 252-PBAU-MTBX-DG-T1-EB 252-PBBU-MTBX-DG-T1-EA 252-PBVU-MTBX-DG-T1-EC Catalog Number

3 Trip Points 3 Trip Points

12 VDC 24 VDC

MISC.

System Phase Sequence & Phase Failure 3 Phase 3 or 4 Wire Phase Balance 3 Phase 3 or 4 Wire 3 Phase 3 or 4 Wire 3 Phase 3 or 4 Wire 3 Phase 3 or 4 Wire Reverse Power 1 ph or 3 ph, 4w 3 Phase, 3 Wire 1 ph or 3 ph, 4w, Push 3 ph 3w Push System Synchro-Check (Paralleling) 1ph or 3ph, 3w or 4w 1ph or 3ph, 3w or 4w System DC Voltage Relay DC Relay DC Relay DC Relay System DC Millivolts/Thermocouple DC Millivolt DC Millivolt DC Millivolt DC Millivolt Thermocouple** Thermocouple** DC Transducer Trip Transducer Transducer Transducer Transducer Transducer Transducer Transducer Transducer Transducer System Speed Sensing 5V to 75V peak to peak

253-PH3U-BGBX-FS-V2 253-PH3U-BGBX-FS-V4

* 20-30V also available ** Specify TC Type and Temperature Range

SPECIFICATIONS Relay Contacts: Temperature: Enclosure: Dimensions:

DPDT, 5A@240VAC/24VDC (resistive) 0-60째C operating (0-40째C for UL) Flame retardant polycarbonate/ABS, IP50 252: 2.2" x 2.8" x 4.4" (55 x 70 x 112 mm) 253: 2.9" x 2.8" x 4.4" (75 x 70 x 112 mm)

132


Crompton System Protection Relay • • • •

Monitor 3Ø Voltage & Current 12 Protective Relay Functions 8 or 12 User Programmable Relays True RMS Measurements

Power Metering

• • • •

Voltage L1-N (L1-L2) Voltage L2-N (L2-L3) Voltage L3-N (L3-L1) Current L1 Current L2 Current L3 Neutral Current Ground Current System Watts System VA System VAr Power Factor Phase Angle Gen Frequency Bus Frequency Gen-Bus Angle

Sync-Check Dead Bus Under Voltage Reverse Power Phase Voltage Sequence

Applications Voltage Unbalance Time Overcurrent

Neutral Ground Fault

AND OR NAND NOR XOR

Over Frequency Under Frequency

ORDERING INFORMATION 4W – PQ LS – C6 – BD – 08 – MB ▲

Nominal Voltage 4W = 4 Wire

Nominal Voltage 3W = 3 Wire

Current

Auxiliary Power

Communications

LS = 5 Amp

BD = 24 Vdc

MB = Modbus RTU

NU = 57.7 Volts L/N NX = 63.5 Volts L/N P7 = 127 Volts L/N PA = 69 Volts L/N PK = 100 Volts L/N PM = 110 Volts L/N PQ = 120 Volts L/N R4 = 220 Volts L/N RQ = 230 Volts L/N RR = 240 Volts L/N RS = 250 Volts L/N R6 = 277 Volts L/N

PK = 100 Volts L/L PM = 110 Volts L/L PO = 115 Volts L/L PQ = 120 Volts L/L RM = 208 Volts L/L RU = 380 Volts L/L RW = 400 Volts L/L SB = 415 Volts L/L SD = 440 Volts L/L SE = 480 Volts L/L

132a

• • • • • • •

General Purpose Protection Generator Protection Motor Protection Cable Protection Feeder Protection Distribution Protection Automatic Transfer Switches

SPECIFICATIONS

Over Voltage

Logic Functions

CR/SPR – 01

High Contrast LCD Display Simple Menu Driven User Interface RS485 Modbus Communications Watchdog Relay

Sync-Check

Voltage Restrained Time Overcurrent

• • • • •

• • • •

ANSI Trip Functions

Up to 34 true RMS power measurements can be made • • • • • • • • • • • • • • • •

Non Volatile Real Time Memory Trip Event History Log Time and Date Stamping Front of Panel Mounting

Current Maximum Primary CT Value Continuous Current Rating Short Duration Current Maximum CT Burden Voltage Maximum Primary PT Value Continuous Voltage Rating Short Duration Voltage Maximum PT Burden Relays Contact Rating Max Breaking Capacity Auxiliary Supply Working Range Power Communications

Frequency

Relays

C5 = 50 Hz C6 = 60 Hz

08 = Eight Relays 12 = Twelve Relays

Operating Temp. Relative Humidity Dimensions Panel Cutout Standards

Isolated 5A CT inputs 10 kA AC 2 x Nominal 20 x Nominal (1 sec) < 0.6 VA Direct or PT inputs 400kV AC 1.2 x Nominal 2 x Nominal (1 sec) < 0.2 VA Form C (NO + NC) 250 V AC, 5 A 2000 VA 24 VDC 9 to 36 VDC < 20 VA 2 wire RS485, Modbus RTU protocol. Includes all features and functions available through the front panel. 0° to +50°C 95% non condensing 7.87”W x 4.17” H x 6.93” D (200 x 106 x 176 mm) 7.36” x 3.66” (187 x 93 mm) ANSI/IEEE C37.90, UL508

138


L

Martel Process Power Supplies STS-3

ORDERING INFORMATION

L

24V loop Power Pack 24V Linear Power Supply 5V Loop Power Supply 12V Loop Power Supply 24V Loop Power Supply

MECPS

L

24.75STS-3 MEC24-1000 MECPS-5 MECPS-12 MECPS-24

For DIN Rail Power Supplies, see Action Instruments Signal Conditioners

MEC24-100

MEC24-1000

MECPS

STS-3

Linear power supply drives up to fifty 4-20mA process loops or power transducers, display devices and other process instruments.

Loop power supply for transmitters, DC operated peripherals and input/output modules on PLCs.

General purpose power supply drives up to eight 4-20mA process loops.

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

Input:

120 VAC or 220 VAC ±10% , user selectable Output: 24VDC ±5% @ 1A (max.) Regulation: Line ±0.2%, Load ±0.2% Input Protection: 0.5A fuse Output Protection: Current limit & Thermal limit Operating Temp.: -20 to +60°C Size: 7.625" x 3.0" x 2.52"

Input: Output: MECPS-5 MECPS-12 MECPS-24 Size:

115VAC ±5%, 60Hz 5V ±0.2 VDC @ 300mA 12V ±0.5 VDC @ 200mA 24V ±1 VDC @ 100mA 3" x 2.2" x 1.4"

Input:

105-125 VAC or 210-250 VAC, user selectable Output: 24VDC @ 0.175mA (max.) Regulation: Line ±0.1%, Load ±0.1% Operating Temp.: -20 to +70°C Size: 3" x 2.7" x 1"

Extech DC Power Supplies • 6 Models, up to 900W Out

• Constant Voltage or Constant Current

• Analog or Digital Display

L

• Single, Triple & Quad Outputs

NEW 382213

Analog 0-30V / 0-3A with fixed 5V/0.5A & 12V/1A outputs Digital 0-30V / 0-3A with fixed 5V/0.5A & 12V/1A outputs 80W three range, single output power supply Quad output power supply Precision 200W single output supply with RS-232 interface 0-30V / 0-30A single output 900W switching supply

382260

L

EX/382203 EX/382213 EX/382260 EX/382270 EX/382280 EX/382290

L

MISC.

ORDERING INFORMATION

382280

SPECIFICATIONS Model Adjustable Outputs: DC Voltage & Current Output Resolution: Basic Accuracy: Ripple and Noise: Line Regulation: Load Regulation: Aux Outputs: Display: Other Features:

133

382203 One 0-30V 0-3A

382213 One 0-30V 0-3A

382260 One 0-16.4V/0-5.1A 0-27.6V/0-3.1A

382270 382280 Four One dual 0-30V / 0-40V 0-5A 0-5A 0-36.8V/0-2.2A --0.1V / 10mA 10mV / 1mA 0.1V / 1mA 10mV / 1mA ±7%FS ±1%FS ±1% ±(0.5%+2d) ±(0.05%+9mV), ±(0.2%+9mA) <5mV <30mV <0.5mV <1mV <3mV <0.05%+10mV <4mV <0.02%+3mV --<0.05%+10mV <20mV <0.02%+3mV 1mV/A fixed 5V/0.5A & 12V/1A --3-6.5V@3A & 8-15V@1A --dual analog dual LCD dual LED four LED LCD series 0-60V@5A 200 setup memory parallel 0-30V@10A RS-232 *Model 382290 900W Switching Suppy has both front panel & remote control of on/off and voltage/current level

382290 One 1-30V 0-30A 10mV / 10mA ±(0.05%+2d) <5mV <0.05%+3mV <0.1%+5mV --Dual LED 10 Turn Pots Remote Sensing*


Control Switches Instrumentation Switches Switch current transformer and potential transformer secondaries to AC ammeters and voltmeters. VOLTMETER SWITCHES

Voltmeter switches are non-shorting (break before make). Ammeter switches are shorting type (make before break).

AMMETER SWITCHES - grounded CT, grounded ammeter

1 CT

3 CTs

3 CTs

61325

4 CTs

AMMETER SWITCHES - 2 pole for floating ammeter

Wiring Diagram

Schematic

61328

MISC.

2 CTs

3 CTs

3 CTs

4 CTs

VOLTMETER / AMMETER SWITCHES - grounded CT, grounded ammeter

ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Example: N20-61336-00 A _ B _ C

A

3 CTs

3 CTs

Position 1 = L1-L2, PH1 2 = L2-L3, PH2 3 = L3-L1, PH3

Position 1 = L1-L2 2 = L2-L3, PH1 3 = L3-L1, PH2 4 = L1-N, PH3

20A, 600V, 12 AWG 25A, 600V, 10 AWG

B

Style Number 613xx Select from style diagrams shown e.g. 61325

C

Mounting

3 CTs Position 1 = L1-N, PH1 2 = L2-N, PH2 3 = L3-N, PH3

Size N20 N25

00 01

48mm plate, 36mm hole pattern 64mm plate, 48mm hole pattern

134


NEW

Weschler Fiberglass Enclosures Standard JIC sizes Durable fiberglass material is easily punched, drilled or sawed UV stabilized for outdoor use Rated NEMA 1, 2, 3, 3R, 4, 4X, 12, 13 Raised cover for additional depth Stainless steel hinge & hardware Optional back panel & hinged deadfront panel Optional polycarbonate window AM2068RTW RoHS compliant

Twist Latch

L

• • • • • • • • •

Snap Latch

These rugged enclosures insulate and protect electronic instrumentation in both indoor and outdoor applications. They are non-corrosive, non-conductive, temperature-resistant and fire-resistant.

DIMENSIONS (inches) Box Size Par t N o. AM664R AM864R AM1084R AM1086R AM1206R AM1426R AM1648R AM1868R AM2068R

H 6.10 8.00 10.14 10.14 12.14 14.13 16.27 18.40 20.00

W 6.10 6.13 8.26 8.26 10.26 12.26 14.40 16.40 16.00

Cover* D 4.18 4.13 4.13 6.13 6.13 6.13 8.13 8.13 8.13

H 7.69 9.59 11.73 11.73 13.73 15.73 17.87 20.00 21.59

Window W 7.69 7.71 9.85 9.85 11.85 13.85 15.99 18.00 17.59

Size 4.25 x 4.25 4.25 x 6.25 6.50 x 8.37 6.50 x 8.37 8.50 x 10.37 10.50 x 12.37 11.00 x 13.00 12.00 x 14.00 11.00 x 15.00

Hinged Panel (optional)

Panel Par t N o. HFP66 HFP86 HFP108 HFP108 HFP120 HFP142 HFP164 HFP186 HFP206

*raised cover adds 1.75" to depth

ORDERING INFORMATION Select part number for a raised panel box from the table. Add suffix: H for Hinged Screw Cover T for Hinged Twist Latch Cover L for Hinged Snap Latch Cover Standard cover is solid front. Add Suffix W for window front. Order Hinged Panel separately, if needed.

MISC.

Weschler Instrument Assemblies • Digital and analog meters mounted in racks or enclosures • Wide range of housings available • For indoor and outdoor applications • Customized layouts and markings • Prewired for quick installation • Use instruments from Weschler or other manufacturers • Include auxiliary indicators, controls & transducers Weschler’s Meter Modification Center can assemble instruments into housings to simplify installation of one instrument or a large instrument cluster. Select the instruments from the broad Weschler line or any of the suppliers listed in this catalog. Products from several manufacturers can be utilized to meet the application requirements. Choose from a wide selection of racks and enclosures to match the size constraints of the installation. Ancillary controls, indicators, signal conditioners and outputs can be added as needed.

Digital Meter in Outdoor Enclosure with Alarm Lights

L

L

Analog Meters on Indoor Enclosure

Typical applications include: - rack mounted instrument clusters for use in a control room, - meters mounted in a portable case for field use, - instruments assembled in a weathertight enclosure for outdoor installation. Contact a Weschler Measurement and Control specialist to discuss your application requirements. Bargraph Draft Gauges in Rack Panel

135

L


Weschler Indoor Enclosures

Pyromation Thermowells

• NEMA 4X & UL508-4X Indoor

Stepped construction increases speed of response while maintaining mechanical strength

Rated • ABS/Polycarbonate Blend • Non-Metallic Hinge & Latch • UL94-5VB Flammability • Includes Stainless Wall Mounting Bracket

• 0.260" bore standard • 304 or 316 stainless steel

ORDERING INFORMATION Insert Code for Each Letter to Select Catalog Number. Example S4C608 S4 A B C A Female fitting C D E B Overall Length 4 6 9 12 C Material 08 09

ORDERING INFORMATION Model NBB-10240 NBB-10241 NBB-10243 NBB-10251 NBB-10247 NBB-10245

Width 5.90 6.79 7.47 10.65 11.73 13.00

Height 5.90 10.75 11.28 14.55 15.68 13.00

Depth 3.57 4.33 5.50 5.92 6.30 7.04

Dimensions in inches. For inside dimensions, subtract 0.9" from Width & Height, 0.3" from Depth

1/2"

NPT NPT 1" NPT 3/4"

4" 6" 9" 12" 316 SS 304 SS

Other lengths, diameters, threads & materials available on request.

Adalet Explosionproof Meter Housings

NEW

• Copper-free Aluminum Casting • Window Cover • Suitable for Meters, Instruments & Control Equipment

MISC.

L

L

XJM

XJS

L XJO Model

Outside* (W H D)

Window

Opening

Inside (W H D)

Under glass

Certifications: UL1203 & CSA C22.2 No. 25 & 30 - Class I, Group B, C, D & Class II Groups E, F, G; UL50 Type 4 XJMAGCHN4

7 3/4

7 3/4

8 1/2

5 1/4 dia

5 3/8 dia

6 3/4

6 3 /4

5

XJMGCHN4

7 3/4

7 3/4

11 1/2

5 1/4 dia

5 3/8 dia

6 3/4

6 3/4

8

XJKGCHN4

10

XJKAGCHN4

10 3/4

12 3/4

1/8

3/8

XJNGCHN4

13

3/4

12 14

3/4

8

15/16

10 15/16 9

13/16

6

11/16

dia

9 dia

9

6 11/16 dia

9 dia

9 1 /2

8 dia

10

3/4

dia

1/2

11

1/2

11

1/2

11 1/2 12

3/4

6

6 7/8 9 7/8 1/8

6 7/8

8 1/2

8 7/8

6

6 5/8

Certifications: UL1203 & CSA C22.2 No. 25 & 30 - Class I, Group C, D & Class II Groups E, F, G; UL50 Type 4 XJOGCN4

9

9

7 9/16

5 1/4 dia

7x7

8

8

5

5 13/16

XJSWGCN4

6 1/8

6 1/8

5 5/8

**

5x5

5 1/4

5 1/4

4 1/2

6 1/8

Dimensions in inches

*excluding mtg tabs

**suitable for 3

1/2"

rectangular & 4

1/2"

round meters

136


Action Instruments Wireless I/O Modules

WPA

L

L

• Compact DIN Rail Package • 2.4 GHz & 900 MHz Versions • 256 bit Encryption Security • Modbus and Profibus Compatible • I/O expandable up to 6 modules • 10-48 VDC or 18-30 VAC power • -40 to 85°C Operating Temperature • CE, CUL, Class 1 Division 2, RoHS Flexible design - the same unit can be programmed as a transmitter, receiver or repeater. Up to 14 mile range (line of sight) with standard antenna.

NEW

WPX

Wireless I/O Base Modules These wireless remote terminal units (RTU’s) can serve as a Modbus slave in radio-based SCADA systems, as a peer-to-peer communication platform, or as a repeater used to extend the range of either of those configurations. Each base module comes has its own I/O (2 DI, 2 DO, 2 AI, 2AO). The industry standard Modbus protocol allows connection to Wonderware, Labview or other Modbus compatible software. Model Number

Frequency

Radio Power

WPR24-2222P

2.4Ghz

50mW

WPR24-2222N

2.4Ghz

50mW

WPR9-2222P

900Mhz

1W

WPR9-2222N

900Mhz

1W

RF Range (Indoor/Outdoor with included Antenna) Up to 183m (600ft)/ Up to 4.8km (3mi) Up to 183m (600ft)/ Up to 4.8km (3mi) Up to 914m (3000ft)/ Up to 22.5km (14mi) Up to 914 (3000ft)/ Up to 22.5km (14mi)

MISC.

Wireless I/O Expansion Modules Expansion modules snap onto the side of the base module. Model Number Description WPX-4AI Four 0-10 VDC or 0-20 mA Analog Inputs WPX-4AO Four 0-10 VDC or 0-20 mA Analog Outputs WPX-8DOR Eight Form C Relay Outputs WPX-4RTDA Four Pt100, Pt1000 or Cu10 RTD inputs (2, 3 or 4-wire)

Wireless Gateways

L WPR

L WPM

Programming Module and Software Wireless gateways and I/O base modules use the same software manager suite. Configuration software is free - no registration fees or worries about installing on multiple machines. Model Number

Description

WPA-PCOM

Programming Module

WPA-PKIT

Programming Module, Cable and Software CD

WPA9-ANT1

Spare antenna, 900MHz, 2dB

WPA9-ANT2

Spare antenna, 900MHz, Omni, 6dB

WPA9-ANT3Y

Spare antenna, 900MHz, Yagi, 9dB

WPA24-ANT1

Spare antenna, 2.4GHz, 2dB

WPA24-ANT2

Spare antenna, 2.4GHz, Omni, 8dB

ACCESSORIES

WPA24-ANT3Y

Spare antenna, 2.4GHz, Yagi, 12.5dB

WPA-OMNI

Omni antenna mounting brackets

WPA-CAB1

Antenna cable, 2ft, SMA-NM

WPA-CAB10

Antenna cable, 10ft, SMA-NM

WPA-CAB20

Antenna cable, 20ft, SMA-NM

WPA-CAB50

Antenna cable, 50ft, SMA-NM

These RS-232/422/485 serial communications modules are compatible with Modbus and Profibus, so no additional converters are required.

WPA-CAB10MM

Antenna cable, 10ft, NM-NM

WPA-CAB20MM

Antenna cable, 20ft, NM-NM

WPA-CAB10FM

Antenna cable, 10ft, NF-NM

Model Number

WPA9-AR1NF

Lightning arrester, 1GHz, 1000W, 350V, 5kA, NFNF

WPM9-1W115K

Frequency Radio Power 900MHz

WPM24-50MW96K 2.4GHz

137

up to 1W

50mW

RF Range (with included Antenna) Up to 3000ft indoor or 14mi outdoor Up to 600ft indoor or 3mi outdoor

Baud

WPA24-AR1NF

Lightning arrester, 2.4GHz, 70W, 130V, 20kA, NFNF

WPA-HKIT

DIN rail clip, spring and 4 screws plus spare terminal block kit and DIP switch cover

115k max

9.6k max

WPA-232USB

Industrial Grade, RS232/USB cable converter

WPA-BOXKIT1

NEMA 4X 10" x 8" x 6" Radio Box, DIN rail, mounting plate & antenna cable


Weschler Zahn Viscosimeter Quickly check the viscosity of paint, varnish, lacquer, inks, syrups, or other liquids. The Zahn viscosimeter (formerly manufactured by G.E.) is a bullet-shaped, corrosion-resistant, stainlesssteel cup with a precision drilled orifice. Five sizes are available. Zahn Cup # Cat. No. 91096971 G1 2 G2 3 G3 4 G4 5 G5

Orifice Use Size (in.) 0.078 Very thin oil or very thin mixture 0.108 Thin oil, mixed paints, lacquers, etc. 0.148 Medium oil and mixed paints, etc. 0.168 Heavy mixtures 0.208 Extremely heavy mixtures

Zahn Viscosimeter

L

Weschler Transformer Advantage Temperature Monitors for Oil-Filled Transformers and Load Tap Changers Choose from 7 Models: All with flexible cooling control, alarm & SCADA capabilities • Single, dual and three channel analog gauge replacements • Calculated winding temperature — no heated thermowell • Fluid, winding and ambient temperature monitor • LTC temperature trend indicator New enhanced features: • 3 winding temperatures • Cooling stage monitor • Auxiliary inputs • RS-485 & Ethernet communications • DNP-3 & Modbus protocols

Transformer Advantage

• Adds EtherNet connectivity to any RS232/485 device • Selectable RS485 line termination and biasing

NEW

SPECIFICATIONS Ethernet: Serial Ports: Baud Rate: Temperature: Case Material: Case Sealing: Dimensions: Power: Isolation:

This converter uses internet protocol message packeting (IP). Screw terminals make installation easy. Configuration is simple and fast using the supplied software.

MISC.

London Electronics Serial to Ethernet Converter

L

Base 10/100 RJ45 RS232 or RS485 (half duplex), switch selectable. Set with PC based configuration software. 0 to 50°C operating UL94 V0 Polycarbonate IP40 5.4"W x 2.5"H x 1.2"D (137x62x30mm) 12 to 30V DC, 2 watts max. 120V AC wall adaper optional Ethernet isolated from power and RS232/RS485. RS232 and RS485 ports not isolated from power.

ORDERING INFORMATION LE/LEM PRE/PSL

Serial to Ethernet Converter with PC software 120VAC to 24VDC wall adapter, 12W

138


ATC Diversified Power Alert • Verifies Zero Energy

SPECIFICATIONS Operating Range:

• Detects Single or 3-Phase AC

Detection Threshold: Operating Temperature: Enclosure: Installation: Terminations: Depth:

• Detects DC or Stored Energy • Redundant Circuitry The eight detector UPA visually alerts to the presence of dangerous AC or DC (Stored Energy) potentials occurring between any combination of the four monitored input lines (L1, L2, L3, GND).

40-750VAC, 50/60/400Hz 30-1000VDC 29VAC 3-phase, 40VAC single phase, 27VDC -20 to 55°C NEMA 4X Requires earth ground connection 6ft leads, #18 AWG UPA-100 1.5" behind panel UPA-130 48mm behind panel

ORDERING INFORMATION

WE/UPA-100 WE/UPA-130

UPA100

Universal Power Alert for 11/4" knockout Universal Power Alert for 30.5mm hole

Madison Annunciators PD141

• 4 Input • NEMA 4X Front • Built-in Horn • SPDT Relay • 1/8 DIN Housing

Accepts a momentary or maintained input from a switch open/close, logic level or open collector transistor. Alarm condition indicated by the built-in horn, LED & fail-safe SPDT relay. Can be configured for ISA Sequence A or ISA Sequence F2A (first out). Gang two modules for an 8 point system. Cat. No.

Power

MD/PD141AFO-2

24-48 VDC

MD/PD141AFO-3

115 VAC

MD/PD141AFO-4

230 VAC

Each message area is 0.5" x 1.25"; specify legends when ordering or make in the field.

Newport Serial to Ethernet

SPECIFICATIONS

NP30011

• Connect RS-232, RS-422 or RS-485 device to an Ethernet network & the Internet • Dynamic IP addressing for easy setup • Static IP addressing to make serial device a node with a unique address • Replaces dedicated wiring and a PC • Easy web based configuration without special software • Includes COM software to redirect data from PC serial port to Ethernet port

138a

Serial Interface: Serial Data: Flow Control: Digital I/O: Network Interface: Protocols: LED Indicators: Management: Web Server: Power Input: Operating Temp.: NP30011 Package: NP30013 Package:

Selectable RS-232, RS-422 or RS-485 (2 wire) 300-115.2 Kbps; 7 or 8 data bits; odd, even or no parity; 1 or 2 stop bits Hardware (RTS/CTS) and Software (Xon/Xoff). 4 digital input/output lines Ethernet 10Base-T, RJ45 connector TCP/IP, UDP/IP, ARP, ICMP, DHCP, DNS, HTTP, Telnet, MODBUS/TCP Network Activity, Network Link, Serial Transmit/Receive Embedded Web server, Telnet login, Serial login Serves dynamic Web pages and Java applets (256kbyte capacity) 9-12VDC (NP30011), 10-32VDC (NP30013) 0 to 70° (32 to 158°F) Metal case, 0.83" x 2.93" x 3.56" (21x62x91mm) Polycarbonate case, 3.54" x 0.99" x 4.53" (91x26x115mm)

ORDERING INFORMATION NP30011 NP30013 NP30015

iServer MicroServer™ with DB9 serial port & universal AC Power adapter iServer DIN Rail MicroServer™ with screw terminal serial port Power Supply (switching) 95-240VAC input, 24VDC output @850mA (for NP30013)


Madison Vertical Float Switches ▲

Each Madison Vertical Float Switch has a dry reed switch in the stem. This switch is closed by the magnet in the float as the level rises.

5600

SPECIFICATIONS Max. PSIG 200 200 200 100 150 150 150 100 100 15

Application High Temperature, High Pressure, Corrosive Conditions Very High Temperature General Purpose, for Acidic Conditions Gasoline and Oil* General Purpose, Low Specific Gravity, for Gasoline and Oil General Purpose, with Metal Stem Outstanding Chemical Resistance

Model Number Standard Miniature 5600 5000 5400 5040 5917 8800 8000 7800 7000* 4300 4500 4600 4400 8600 8020 8400 8040 9800 9000

Float Stem Max. Material Material Temp. 316SS 316SS 200˚C 316SS Brass 200˚C 316SS 316SS 250˚C Polypropylene Polypropylene 105˚C Buna-N PBT 105˚C Buna-N Brass 105˚C Buna-N 316SS 105˚C Polypropylene 316SS 105˚C Polypropylene Brass 105˚C Kynar Kynar 100˚C *Not for use in water above 65°C Standard = 60VA Contacts, 1/4" NPT Fitting Miniature = 30VA Contacts, 1/8" NPT Fitting

8000

ORDERING INFORMATION To order use prefix and model number from chart above. Example: MD/MS4600 MD/M4 Prefix for units w/o Sloss Shield MD/MS Prefix for units with Sloss Shield

Monarch Palm Strobe • One touch tuning • Flash rates to 12500 FPM • Tachometer mode • TTL compatible input/output • Memory recall • Rechargeable battery Four quadrant joystick button adjusts flash rate, x2, ÷2.

SPECIFICATIONS Operating Modes

Battery Run Time Display

Internal 100-12500 FPM External 5-12500 FPM Tach 5-250000 RPM 1 hour typical 6 digit backlit LCD

ORDERING INFORMATION MN/6205-010 MN/6205-013

138b

Palm Strobe, with charger Palm Strobe Kit (spare battery & lamps, holster & case)

140


Fluke Handheld Oscilloscopes The 125 offers additional capabilities for testing industrial machinery:

The ScopeMeter 190 Series of high performance oscilloscopes have bandwidth of 60, 100, and 200 MHz and sample rates up to 2.5 GS/s. The high resolution color display has a fast update rate and digital persistence mode – making the analysis of complex and dynamic signals that much easier.

124

L

Choose the 190 Series for tough troubleshooting problems, like intermittent failures, impulses and signal fluctuations in high speed or sensitive electronic or electromechanical systems. They include automatic measurements, cursors, FFT analysis, paperless recording functions and a DMM input.

199C

For industrial electronic or electromechanical applications, the 120 Series Industrial ScopeMeters offer bandwidth to 40MHz, a dual DMM and paperless recording.

L

ScopeMeter 190C Series Fluke 199C Bandwidth Max. real time sample rate Display Persistence Max. record length Number of inputs Number of digitizers Independently floating isolated inputs Input sensitivity Glitch capture

TEST EQUIPMENT

Timebase range in Scope mode Trigger types Scope Measurements Power Measurements Scope-Record Trigger modes Capture last 100 screens Dual input TrendPlot Memory for screens

Fluke 196C

• Power & harmonic measurements for single phase and balanced 3-phase systems. • RPM and Hz reading for motors & engines. • Vac PWM for motor drive outputs. • 0.01 ohm resolution for motor & transformer windings. • a Bus Health function for troubleshoting industrial data networks. For fast measurement answers and quick display of waveforms all ScopeMeters include Connect-and-View triggering. This feature recognizes signal patterns and automatically sets the oscilloscope for a stable reliable display of even the most complex waveforms. Move from test point to test point and the ScopeMeter will continuously lock onto just about any waveform.

NEW Fluke 192C

200 MHz 2.5 GS/s

100 MHz 60 MHz 1 GS/s 0.5 GS/s 14.4 cm Full Color LCD Digital Persistence giving analog oscilloscope-like waveform decay 3000 points per input (Scope mode) 27500 points per input (ScopeRecord mode) 2 plus external/DMM input all isolated from each other and ground 2 Up to 1000 V between inputs, references and ground 2 mV/div. … 100 V/div. Up to 3 ns using Pulse Width triggering 50 ns peak detect at 5 ms/div. to 1 min/div 5 ns/div. to 2 min/div. Connect-and-View® , Free Run, Single Shot, Edge, Delay, Video, Video line, Selectable pulse width and External 7 cursors , 30 automatic measurements ––– Start on Trigger / Stop on Trigger

Industrial ScopeMeters Fluke 123 20 MHz 25 MS/s

Fluke 124

40 MHz 40 MHz 25 MS/s 25 MS/s 10.2 cm Monochrome LCD ––– 512 min/max pairs per input 2 2 600 V RMS max input or any terminal to ground 5 mV/div. … 500V/Div 40 ns

10 ns/div. to 20 ns/div. to 1 min/div. 1 min/div. Connect-and-View®, Free Run, Single Shot, Edge, Video, External 26 automatic measurements W, VA, VAR. PF -

Automatic with Replay capability Yes with Cursors and Zoom Yes Yes 15 screens and set-ups, 10 20 2 replay and set-ups Memory for recordings Two, each can store 100 scope screens, a ScopeRecord or a TrendPlot 1 True RMS multimeter 5000 counts, Volts, Amps, Ohms, Continuity, Diode, Temp Safety certified 1000 V CAT II / 600 V CAT III (instrument and included accessories) 600 V CAT III Battery power 4 hr NiMH battery installed 7 hr NiMH Line power Adapter/battery charger included Size (cm)/Weight 25.6 x 16.9 x 6.4/2 kg 23.2 x 11.5 x 5.0/1.2 kg Temperature 0-50°C operating, -20 to +60°C Storage PC and Printer interface Using optional Optically Isolated adapter/cable Warranty 3 years (1 year on accessories) Add /S to model number to include Flukeview software, isolated USB cable & hard carrying case

139

Fluke 125


Fluke High Performance Digital Multimeters

NEW

The Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents performance and graphically displays results. • Large 50,000 count, 1/4 VGA display with white backlight. Displays multiple sets of measurements simultaneously • Logging function with expanded memory stores up to 15,000 recorded events • TrendCapture graphically displays logged data session • Zoom up to 14X to view & analyze TrendCapture data • Selectable ac filter helps display rapidly changing or noisy signals • Adjustable recording & auto hold thresholds, specify a percentage change in the readings that begins a new event • On board help screens for measurement functions

287

L

Includes manual, 6 AA batteries, TL71 silicone test leads, probe holder, two AC72 alligator clips

• • • • • • •

Multiple logging sessions without download 0.025 % basic dc accuracy True-rms ac and ac+dc 100 kHz ac bandwidth Real-time clock time-stamps saved readings Peak capture to record transients as fast as 250 µs Relative mode to remove test lead resistance from low ohms or capacitance measurements • Optional FlukeView software to document, store and analyze measurements • CATIII – 1000V & CAT IV – 600V ratings • Limited lifetime warranty

SPECIFICATIONS Function

Range & resolution

VDC, VAC ADC, AAC Resistance Capacitance Frequency Temperature

50.000 mV, 500.00 mV, 5000.0 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V 500.00 µA, 5.000 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A* 500.00Ω - 500.0 MΩ (7 ranges) 1.100 nF - 100.0 mF (9 ranges) 99.999 Hz - 999.99 kHz (5 ranges) -200 to 1350°C, -328 to 2462°F

Battery life: Environment:

Basic Accuracy

100 hours minimum, 200 hours in logging mode -20°C to 55°C, <90% RH up to 37°C

0.025% (0.4% AC) 0.15% (0.7% AC) 0.05% 1.0% 0.005% 1.0%

*10A continuous, 20A for up to 30 seconds. Size: 222x102x60 mm (8.75 x 4.03 x2.38")

Fluke 289 adds 50Ω range for measuring contacts & motor windings plus a LowZ voltage function for eliminating ghost voltages.

The Fluke 87V has improved measurement functions & troubleshooting features, to solve problems on motor drives, inplant automation, power distribution and electro-mechanical equipment. • Selectable filters for accurate measurements on adjustable speed drives • Built-in thermometer

• • • •

Capacitance to 10,000µF 30% larger display 2 level backlight 4x faster (250µS) peak capture

• CATIII-1000V & CATIV-600V rating • Lifetime warranty

SPECIFICATIONS

L

Includes: TL75 Test Leads, AC72 Alligator Clips, holster, 9V battery, temperature probe

Range & resolution 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 600.0 µA, 6000 µA, 60.00 mA, 600.O mA, 6.000 A, 10.00 A 600.0 µA, 6000 µA, 60.00 mA, 600.O mA, 6.000 A, 10.00 A -200 to 1090 °C (-328 to 1994 °F) -40 to 260 °C (-40 to 500 °F) 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ, 50.00 MΩ 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 9,999 µF 199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz

Battery Life: 100 hours typical with headlight off. Size: (LxWxD): 201mm x 98mm x 52mm (7.9in x 3.6in x 2in)

Fluke 87V/E2 Industrial Electrician Combo Kit Includes special accessories to increase productivity. • 1.5m heat resistance silicone test • Magnetic hanger to position and hold meter to steel surfaces leads • Removable test probes with 4mm • Temperature probe of exposed metal for use on • Packaged in a durable carrying industrial circuits case • Plunger style alligator clips

Basic Accuracy (87V) 0.05 % 0.7 % (True-rms) 0.2 % 1.0 % (True-rms) 1.0 % 2.2 °C or 2 % 0.2 % 1.0 % 0.005 %

ORDERING INFORMATION Fluke-87-5 Industrial True-rms Multimeter with Temperature Fluke-87-5/E2 Industrial Electrician Combo Kit Fluke-287 True-rms Electronics Logging Multimeter Fluke-289 True-rms Electronics Logging Multimeter FVF-SC2 FlukeView® forms software with cable 80BK Integrated DMM temperature probe i410 AC/DC current clamp TLK287 Electronic test lead set TPAK Magnetic hanging kit C280 Soft case

140

TEST EQUIPMENT

87V

Function DC Volts AC Volts DC Current AC Current Temperature (excl. probe) 80BK Temperature Probe Resistance Capacitance Frequency


Fluke Compact Digital Multimeters These little meters pack more features than some DMMs twice their size:

M

Fluke 117

• True-rms ac voltage and current measurement for accurate readings on all waveforms • 6000-count display provides improved resolution • Min/Max/Average feature captures signal fluctuations

• Frequency, capacitance and diode test capabilities (except 114) • White LED backlight for excellent visibility • Fast continuity test detects intermittent connections • IEC CAT III 600V safety rating • Auto-Volt automatic ac/dc voltage selection

SPECIFICATIONS Every Fluke 110 Series meter comes with a protective holster, TL75 test leads, 9V battery (installed) and manual.

ORDERING INFO Fluke-114 Fluke-115 Fluke-116 Fluke-117

Electrical Multimeter Multimeter HVAC Multimeter w/ temp. probe Electrician’s Multimeter Meter hanging kit with magnet Alligator clips Carrying case

Range & resolution

Best accuracy

VDC VAC1 ADC (Models 115 & 117 only) AAC (Models 115 & 117 only) Resistance

600.0 mV, 6.000 V, 60.00 V, 600.0 V 600.0 mV, 6.000 V, 60.00 V, 600.0 V 6.000 A, 10.00 A2 6.000 A, 10.00 A2 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ, 40.00 MΩ 1000 nF, 10.00 µF, 100.0 µF, 9999 µF 99.99 Hz, 999.9 Hz, 9.999 Hz, 50.00 kHz

±0.5 % of rdg + 2 d ±1.0 % of rdg + 3 d ±1.0 % of rdg + 3 d ±1.5 % of rdg + 3 d

Capacitance (except Model 114) Frequency3 (except Model 114)

RECOMMENDED ACCESSORIES TPAK AC220 C50

Function

1 Specified from 1% of range to 100% of range; CF < 3 up to 4000 counts, 1.5 at full scale. 2 10 A continuous, 20 A for up to 30 seconds, 45-500 Hz. 3 Frequency is ac coupled 5 Hz to 50 kHz for ac volts. Frequency is dc coupled 445 Hz to 5 kHz for ac current. AC volts is ac-coupled. Auto-V, LoZ and ac mV are dc-coupled. Battery life: 400 hours typical for alkaline. 33 segment Bargraph display updates 32x/sec.

±0.9 % of rdg + 1 d ±1.9 % of rdg + 2 d ±0.1 % of rdg + 2 d

Additional Model 116 features: • °F/°C temperature function for HVAC troubleshooting • 600µA ac & dc ranges for testing flame sensors

Fluke Digital Multimeters

TEST EQUIPMENT

M

Fluke 179

The 170 series replaces the popular 70 Series. The 175, 177 and 179 are designed tough to withstand the harshest work environments. Accuracy rivals most bench meters.

Every Fluke 170 Series meter comes with TL75 test leads, 9V battery (installed) and manual. The Fluke 179 also includes an 80BK Temperature Probe.

• • • • • • •

• The 179 measures temperature in °C and °F • 177 and 179 have a backlight to illuminate the screen in dark workspaces • IEC 1010 CAT IV 600V, CAT III 1000V safety ratings • Drop protected to 1 meter • Overmolded case features integrated probe holders • Compatible with ToolPak™ meter hanging kit

Lifetime warranty 6000 count display 0.09% basic dc accuracy (177 & 179) True-rms ac voltage and current measurement Min/Max/Average records irregular activity Auto and Manual hold Frequency, capacitance and resistance capabilities

ORDERING INFO

SPECIFICATIONS Function

Range & Resolution

VDC

600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000V

VAC1 ADC AAC Resistance Capacitance Frequency3 Temperature (Model 179)

600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000V 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ, 50.00 MΩ 1000 nF, 10.00 µF, 100.0 µF, 9999 µF 99.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz

Best accuracy ±0.09 % (177 & 179) ±0.15 % (175) ±1.0 % of reading ±1.0 % of reading ±1.5 % of reading ±0.9 % of reading ±1.2 % of reading ±0.1 % of reading

-40 °C to +400 °C, -40 °F to +752 °F

All AC voltage and AC current ranges are specified from 5% of range to 100% of range. 2 10 A continuous, 20 A for up to 30 seconds. 3 Voltage Frequency is specified from 2 Hz to 100 kHz. Current Frequency is specified from 2 Hz to 30 kHz. Battery life: 200 hours typical for alkaline Size: (H x W x L): 4.3 cm x 9.0 cm x 18.5 cm Lifetime Warranty 1

141

1.0% of reading

Fluke-175 Fluke-177 Fluke-179

Digital Multimeter Digital Multimeter Digital Multimeter

RECOMMENDED ACCESSORIES TPAK C25 C510 i 200 TL223

Meter hanging kit with magnet Soft vinyl carrying case Top grain leather carrying case AC current clamp Electrical test lead set


Extech Industrial MultiMeters

Extech Autoranging MultiMeters

• • • • • • • • • •

• • • • • • •

L

450

Model 450 • • • •

2000 Count Full Scale 0.05% Basic DCV Accuracy IR Laser Thermometer MAX function

L

530

L

Model EX520 • 6000 Count - High Resolution • 0.09% Accuracy • Min/Max/Relative/Data Hold • 20A Max Current

430

Model 430

®

• • • • • •

4000 Count Full Scale TRMS AC 0.03% Basic DCV Accuracy Capacitance & Frequency Type K TC Temperature Relative Function 470

Model 470

all of the Model 430 features plus • IR Laser Thermometer

SPECIFICATIONS Measurement Range DCV 0.1mV to 600V ACV 0.1mV to 600V DCA 0.1mA to 20A ACA 0.1mA to 20A Ω 0.1Ω to 40MΩ (20MΩ on Model 450) Models 430 & 470: Capacitance 0.01nF to 100µF Frequency 0.001Hz to 10MHz Duty cycle 0.1 to 99.9% Type K TC -4 to 1382°F (-20 to 750°C) IR Thermometer (Models 450 & 470): Range -4 to 518°F (-20 to 270°C) Spot size 8:1 Emissivity 0.95 All models supplied with CAT III test leads, multi-position tilt stand and velcro strip for hanging, protective holster with test lead holder, bead wire temperature probe (except Model 450) and battery.

ORDERING INFORMATION True RMS Industrial MultiMeter (4000 count) True RMS Industrial MultiMeter (6000 count) True RMS Industrial MultiMeter (40,000 count) Electrical Test Lead Kit Type K Clamp Probe (212°F/100°C) Magnetic Hanging Strap

ORDERING INFORMATION EX450 EX430 EX470 EX/CA310 EX/380905 EX/409996

MultiMeter with IR Thermometer TRMS MultiMeter TRMS MultiMeter w/ IR Thermometer 300A AC clamp-on adapter 2000A AC/DC clamp-on adapter Pouch carrying case

142

TEST EQUIPMENT

Complete with double molded test leads, magnetic hanging strap, Type K bead wire temperature probe (-22 to 572°F/-30 to 300°C), carrying case, and 9V battery.

L

SPECIFICATIONS Measurement Range (auto or manual ranging) DCV 0.1mV to 1000V (0.01mV on EX530) ACV 1mV to 1000V (0.1mV on EX505, 0.01mV on EX530) DCA 0.1mA to 20A (10A on EX505) ACA 0.1mA to 20A (10A on EX505) Ω EX505: 0.1Ω to 40MΩ EX520: 0.1Ω to 60MΩ EX530: 0.01Ω to 40MΩ Capacitance EX505: 0.01nF to 100mF EX520: 0.01nF to 1000mF EX530: 0.001nF to 40mF Frequency Electrical Electronic EX505: 5Hz to 1kHz 0.001Hz to 10MHz EX520: 10Hz to 400Hz 0.001Hz to 40MHz EX530: 40Hz to 400Hz 0.001Hz to 100MHz Temperature -50 to 1382°F / -45 to 750°C (-4°F/-20°C min on EX505) Duty Cycle 0.1 to 99.9% Diode/Continuity Yes

EX505 EX520 EX530 EX/TL810 EX/TP200 EX/HG500

®

520

Model EX505 • 4,000 Count • 0.5% Accuracy • Data Hold and Relative • 10A Max Current

Model EX530 • 40,000 Count - Highest Resolution • 0.06% Accuracy • Min/Max/Relative/Data Hold • 20A Max Current • Peak Hold (AC only)

Backlit 1" High LCD Resolution to 0.1mA CAT III - 600V Rating Audible & Visual Alerts Diode/Continuity Check Three Year Warranty Built-in IR thermometer with laser (450 & 470)

L

L

Double Molded Waterproof Case (IP67) 11 Functions 1000V Protection on All Functions 505 True RMS AC Dual Sensitivity Frequency Functions Large Backlit LCD Diode Test Open Circuit 2.8V DC Auto Power Off with Disable Feature CATIII-1000V & CATIV-600V Ratings Drop Proof to 6 Feet


Fluke Clamp Meters Seven new models offer an impressive array of innovative features with current ranges up to 1000A. Choose the model that matches the jobs you do. • Auto shut-off maximizes battery life so the meter works when you need it • Small body and jaws fit perfectly in your hand and into tight places • Large, backlit display (on most models) is easy to see • In-rush current function (on most models) for measuring starting current for motors, lighting, etc. • Improved low current measurement accuracy from new microprocessor technology

• Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch) • Handy display hold keeps measurements on the display • CAT III – 600V Rating

SPECIFICATIONS Fluke 333

Fluke 334

Fluke 335

Fluke 336

Fluke 337

Fluke 321

Fluke 322

AC amps Range

0-400.0A

0-600.0A

0-600.0A

0-600.0A

0-999.9A

0-400.0A

40.00A/400.0A

2% ± 5 counts (50/60 Hz)

2% ± 5 counts (50/60 Hz)

2% ± 5 counts (50/60 Hz)

2% ± 5 counts (10-100 Hz) 6% ± 5 counts (100-400 Hz)

2% ± 5 counts (10-100 Hz) 6% ± 5 counts (100-400 Hz)

1.8% ± 5 counts (50/60Hz)

1.8% ± 5 counts (50/60Hz)

Crest factor

2.4 @ 500A 2.0 @ 600A add 2% for C.F.>2

3 @ 500A 2.5 @ 600A add 2% for C.F.>2

3 @ 500A 2.5 @ 600A 1.42 @ 1000A add 2% for C.F.>2

AC response

Averaging

Averaging

True-rms

True-rms

True-rms

Averaging

Averaging

Accuracy

337

L

321

L

DC amps Range

0-600.0A

0-999.9A

Accuracy

2% ± 3 counts

2% ± 3 counts

AC volts Range Accuracy

AC Response

0-600.0V

0-600.0V

0-600.0V

0-600.0V

0-600.0V

0-600.0V

0-600.0V

1% ± 5 counts (50/60 Hz)

1% ± 5 counts (50/60 Hz)

1% ± 5 counts (50/60 Hz)

1% ± 5 counts (20-100 Hz) 6% ± 5 counts (100-400 Hz)

1% ± 5 counts (20-100 Hz) 6% ± 5 counts (100-400 Hz)

1.2% ± 5 counts (50-400Hz)

1.2% ± 5 counts (50-400Hz)

True-rms

True-rms

Averaging

Averaging

Averaging

True-rms

Averaging

DC volts Range

0-600.0V

0-600.0V

0-600.0V

0-600.0V

0-600.0V

400.0V/600V

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

1% ± 5 counts

0-600.0Ω

0-600.0Ω 600-6000Ω

0-600.0Ω 600-6000Ω

0-600.0Ω 600-6000Ω

0-600.0Ω 600-6000Ω

0-400.0Ω

0-400.0Ω

1.5% ± 5 counts

1.5% ± 5 counts

1.5% ± 5 counts

1.5% ± 5 counts

1.5% ± 5 counts

1% ± 5 counts

1% ± 5 counts

≤ 30Ω

≤ 30Ω

≤ 30Ω

≤ 30Ω

≤ 30Ω

≤ 30Ω

≤ 30Ω

Range

5-400 Hz

Accuracy

0.5% ± 5 counts

Trigger Level

10-100 Hz ≥5A 5-10 Hz ≥10A 100-400 Hz ≥10A

100 mS

Accuracy Ohms Range Accuracy Continuity

TEST EQUIPMENT

Frequency

Inrush Integration time

100 mS

100 mS

100 mS

MIN/MAX

Backlight

Max. Wire Diameter

Fluke 321 Fluke 322 Fluke 333

Fluke 335 Fluke 336

9.4 x 3.1 x 1.6"

9.9 x 3.1 x 1.6"

7.5 x 2.5 x 1.4"

1.2"

1.2"

1"

Operating Temperature: -10°C to 50°C (14 °F to 122 °F) Temperature De-rating: Add 0.1 x specified accuracy for each °C above 28 °C or below 18 °C Altitude: 2,500 meters for 330 series, 2000 meters for 320 series Battery Life: Alkaline - approximately 150 continuous hours for 330 series, 100 hours for 320 series Storage Temperature: -40 °C to 60 °C (-40 °F to 140 °F) for 330 series, -30 °C to 60 °C (-22 °F to 140 °F) for 320 series Warranty: 3 years on 330 series, 2 years on 320 series

143

ORDERING INFORMATION

Fluke 334

Display Hold Size

ACCESSORIES Included accessories Soft Carrying Case, TL75 Test Leads, (2) AA Alkaline Batteries, Coated Instruction Card & Safety Information Sheet

Fluke 337

AC Clamp Meter AC/DC Clamp Meter 400A AC Averaging Clamp Meter 600A AC Averaging Clamp Meter 400A AC TRMS Clamp Meter 600A AC/DC TRMS Clamp Meter 1000A AC/DC TRMS Clamp Meter


Yokogawa Clamp-On Testers AC Current CL100 Series

AC/DC Current CL200 Series • AC & DC Current to 2000A • AC & DC Voltage Measurements • Resistance / Continuity • TRMS & Frequency (CL235 & CL255) • Peak / Data Hold CL250

L

L

• AC Current to 2000A • AC Voltage Measurement • Resistance / Continuity (CL130 & CL150) • Data Hold • IEC CAT III CL130

ORDERING INFORMATION YE/CL120 200A AC Clamp-On Tester YE/CL130 600A AC Multi-Function Clamp-On Tester YE/CL135 600A AC TRMS Multi-Function Clamp-On Tester* YE/CL150 2000A AC Multi-Function Clamp-On Tester YE/CL220 300A AC/DC Clamp-On Tester YE/CL235 600A AC/DC TRMS Multi-Function Clamp-On Tester YE/CL250 2000A AC/DC Multi-Function Clamp-On Tester YE/CL255 2000A AC/DC TRMS Multi-Function Clamp-On Tester YE/CL320 200A AC Clamp-On Leakage Tester YE/CL340 400A AC Clamp-On Leakage Tester YE/CL360 1000A AC Clamp-On Leakage Tester *same features as CL130, except TRMS

AC Leakage Current CL300 Series • AC Current to 1000A • AC Leakage with 10µA Resolution • Wide Jaw Opening • AC & DC Recorder Outputs (CL360) • Peak / Data Hold

L

CL360

Limited Lifetime Warranty on all Models

Resistance

TRMS

Frequency

Continuity Check

Peak Hold

Data Hold

Recorder Output

300V (1 range)

-

-

-

-

-

-

24mm 0.95"

CAT III 300V

CL130 2000

-

200/600A (2 ranges)

-

200/600V (2 ranges)

200Ω (1 range)

-

-

-

-

33mm 1.30"

CAT III 600V

CL150 4000

-

400/2000A (2 ranges)

40/400/750V 40/400/750V 400/4000/40k/400kΩ (3 ranges) (3 ranges) (4 ranges) -

-

-

• •

55mm 2.16"

CAT III 600V CAT II 1000V

CL220 4000

40/300A (2 ranges)

40/300A (2 ranges)

-

-

-

-

24mm 0.95"

CAT III 300V

CL235 4000

400/1000A (2 ranges)

400/600A (2 ranges)

40/400/600V 40/400/600V (3 ranges) (3 ranges)

400/4000Ω (2 ranges)

• •

• • •

-

33mm 1.30"

CAT III 600V

CL250 4000

400/2000A (2 ranges)

400/2000A (2 ranges)

40/400/1000V 40/400/750V (3 ranges) (3 ranges)

400/4000Ω (2 ranges)

-

• •

55mm 2.16"

CAT III 600V CAT II 1000V

CL255 4000

400/2000A (2 ranges)

400/2000A (2 ranges)

40/400/1000V 40/400/750V (3 ranges) (3 ranges)

400/4000Ω (2 ranges)

• •

• • • •

55mm 2.16"

CAT III 600V CAT II 1000V

-

20/200mA 200A (3 ranges)

-

-

-

-

-

-

-

-

24mm 0.95"

CAT III 300V

-

40/400mA 40/400A (4 ranges)

-

-

-

-

-

-

• •

-

40mm 1.57"

CAT III 300V

-

-

-

-

-

-

• • •

68mm 2.68"

CAT III 300V

CL340 4000

-

-

-

-

-

200mA 2/20/200/1000A

CL360 2000

-

(5 ranges)

144

TEST EQUIPMENT

CL320 2000

-

Rating

AC Voltage

-

Jaw opening capacity

DC Voltage

20/200A (2 ranges)

DC Current -

Display

CL120 2000

Model No.

AC Current

Functions


Extech Clamp Meters Model EX623

NEW

800A Clamp Meters

400A Dual Input Clamp Meters + IR Thermometer + Non-Contact Voltage Detect

• AC/DC Current, AC/DC Voltage,

• TRMS AC Voltage & Current measurements • Dual type K thermocouple input with

• • • • • •

Differential Temperature function

• Non-contact Voltage detector with LED alert • Non-contact IR Thermometer with laser pointer for locating hot spots

• DC Voltage, DC Current, Resistance, Capacitance,Frequency & Duty Cycle functions • Autoranging with manual override • Data Hold plus fast Peak Hold for surges • Complete with test leads, 9V battery, two Type K bead wire probes and case

Resistance, Frequency, Capacitance, Temperature, Diode Test and Continuity True RMS models 1.2" (30mm) circular jaw opening Backlit LCD Peak, Data Hold, Auto power off DC Current with Zero (EX730) Complete with test leads, 9V battery, Type K bead wire probe (EX720, EX730) and carrying case

200A AC/DC Mini Clamp plus MultiMeter

L Model EX623

L Model EX730

• High resolution to 10mA • Measures voltage, resistance and frequency

• Fast 40 segment bargraph • One touch auto zero for

Model MA640

DC current measurements 600A True RMS Clamp Meters + Non-Contact Voltage Detect • TRMS AC Voltage & Current measurements • Non-contact Voltage detector with LED alert • DC Voltage, DC Current, Resistance, Capacitance, Frequency, Temperature, Duty Cycle • Relative Mode for Capacitance Zero and Offset Adjustment • Data Hold and MIN/MAX • Complete with test leads, Type K bead wire probe, 9V battery and carrying case

• Min/Max • Data hold and auto power off • Complete with test leads, wrist strap,

L Model 380941

2 AA batteries and carrying case 30A True RMS AC/DC Mini Clamp

• Measure low AC/DC current with resolution to 1mA DC and 0.1mA AC

• Also measures voltage • Fast 40 segment bargraph • One touch auto zero for DC current measurements

L Model MA640

• Min/Max • Data hold and auto power off • Complete with test leads, wrist strap,

L Model 380942

2 AA batteries and carrying case

TEST EQUIPMENT

SPECIFICATIONS Model AC Sensing: Display counts: Jaw size/ Cable size:

EX623 TRMS 4000 1.4" (36mm)

MA640 TRMS 6000 1.5" (40mm)

380941 Averaging 4000 0.9" (23mm); 4/0 AWG

380942 TRMS 4000 0.9" (23mm); 4/0 AWG

AC Current: DC Current: Max resolution: Basic AC/DC Accuracy: AC/DC Voltage (Max. Res.):

60A, 600A 60A, 600A 0.01A ±2.8% AC: 600V (1mV) DC: 600V (0.01mV) 60MΩ (0.1Ω) 4000µF (0.01nF) 10kHz (0.01Hz) -4 to 1400°F

40A, 200A 40A, 200A 0.01A ±1.0% 400V (0.1V)

Resistance (Max Res.): Capaciatance (Max Res.): Frequency (Max. Res.): Temperatures (Type K):

400µA , 40A, 400A 400µA , 40A, 400A 0.1µA, 0.01A ±1.5% AC: 600V (0.1V) DC: 600V (0.01mV) 40MΩ (0.01Ω) 40mF (0.01nF) 100MHz (0.01Hz) -58 to 1832°F

IR Temperature: Diode/Continuity: Data Hold: Min/Max/Peak: Safety Rating:

-58 to 518°F Yes Yes Yes CAT III-600V

—Yes Yes Yes CAT III-600V

145

400mA, 4A, 30A 4A, 30A AC: 0.1mA, DC: 0.001A ±1.5% 400V (1V)

EX710 Averaging 4000, backlit 1.2" (30mm): 500MCM 800A —0.01A ±2.8% 600V (0.1mV)

EX720 TRMS 4000, backlit 1.2" (30mm): 500MCM 800A —0.01A ±3% 600V (0.1mV)

EX730 TRMS 4000, backlit 1.2" (30mm): 500MCM 800A 800A AC: 0.01A, DC: 0.1A AC: ±3%, DC: ±2.5% 600V (0.1mV)

400Ω (0.1Ω) —1000kHz (0.01Hz) —-

————-

40MΩ (0.01Ω) 40mF (0.001nF) 4kHz (1Hz) —-

—Continuity Yes Min/Max CAT III-300V

——Yes Min/Max CAT III-300V

—Yes Yes Peak CAT III-600V

40MΩ (0.01Ω) 40mF (0.001nF) 4kHz (1Hz) -4 to 1832°F / -20 to 1000°C —Yes Yes Peak CAT III-600V

40MΩ (0.01Ω) 40mF (0.001nF) 4kHz (1Hz) -4 to 1832°F / -20 to 1000°C —Yes Yes Peak CAT III-600V


Ideal Clamp Meters Backlit TightSight™ bottom display for viewing in dark, bright, or tight locations.

SPECIFICATIONS – 770 SERIES

• 600A & 1000A models • Two backlit LCD displays • Voltage-presence warning on all functions • Tapered jaws with hook tip • Max/min • Peak max/min (1ms) • Audible continuity • Selectable auto power off • Data hold • Low battery indicator • Hinged rubber cover protects end display • CATIV- 600V, CATIII-1000V rating

L

61-772

Jaw Size 2" (51 mm) Range 61-772 61-774 AC Current 400.0/1000 A DC Current –– 400.0/1000 A AC Voltage 400.0m/4.000/40.00/400.0/750 V DC Voltage 400.0m/4.000/40.00/400.0/1000 V Resistance 400.0/4.000k/40.00k/400.0k/ 4.000M/10.00M Ω Capacitance –– 4.000µ/40.00µ 400.0µ/4.000m F

Accuracy 1.7% 1.5% 1.2% 0.5% 1.0% 3.0%

SPECIFICATIONS – 760 SERIES Jaw Size 1.42” (36 mm) Range 61-764 61-766 61-768 AC Current 400.0/600 A 40.00/400.0/600 A 400.0/600 A DC Current –– –– 400.0/600 A AC Voltage 400.0m/4.000/40.00/400.0/750 V DC Voltage 400.0m/4.000/40.00/400.0/1000 V Resistance 400.0/4.000k/40.00k/400.0k/4.000M/10.00M Ω Capacitance –– 4.000µ/40.00µ –– 400.0µ/4.000m F Frequency –– 0.020k to 0.400k Hz –– Sensitivity is 20-100 Hz(≥ 5A) 100-400Hz(≥ 10A)

ORDERING INFORMATION Includes leads, alligator clip and case SP/61-772 1000AAC TRMS Clamp Meter SP/61-774 1000AAC TRMS Clamp Meter w/ DC Current, Capacitance SP/61-764 600AAC Clamp Meter SP/61-766 600AAC TRMS Clamp Meter w/ Capacitance, Frequency, 40A Range SP/61-768 600AAC TRMS Clamp Meter w/ DC Current

Accuracy 1.7% 1.5% 1.2% 0.5% 1.0% 3.0% 0.1%

Megger Clampmeters MULTI-CORE CLAMPMETER

LEAKAGE CLAMPMETER

L

• Measure single, two or three core cables • No need to split wires • Cable centering clamp • Backlit display

L

MMC850

• 0.01mA resolution for measuring earth leakage currents • Amp ranges for standard current measurements • Analog bargraph display for trending • 40mm jaw opening

DCM300E

SPECIFICATIONS

AC Amps Mode: Range: Resolution: Accuracy: Frequency:

Single-Core Mode 200A 0.1A ±1.5% ±3d 45Hz - 1kHz

Main Jaw Capacity: Inner Jaw Capacity: Display: Operating Temp.: Storage Temp.: Battery: Battery Life: Dimensions: Safety:

13mm (0.51") 22mm (0.87") 31/2 digit, 2000 count 0ºC to +40ºC, <80% RH -20ºC to +60ºC, <70% RH 9V Alkaline 180hrs typical 8.94" x 3.7" x 1.75" (227 x 94 x 44.5mm) IEC1010-2-032, CAT III 600V

Multi-Core Mode 100A 0.1A ±5% ±10d 45Hz - 400Hz

30mA/300mA/30A/300A (50/60Hz) ±1.2% rdg ±5d ±1.2% rdg ±5d ±3.0% rdg ±5d ±5.0% rdg ±5d 600V AC max. 40mm (1.57") 31/2 digit, 3200 count Indicated by DH in display 0ºC to +40ºC, <80% RH -20ºC to +60ºC, <70% RH 2 LR44 button cells 2.5" x 7" x 0.9" (64 x 176 x 23mm) 300V phase to earth, 500V phase to phase CAT III or 600V CAT II

ORDERING INFORMATION ME/MMC850 ME/DCM300E

Multi-Conductor AC Clamp Meter with carrying case Leakage Clampmeter with carrying case

146

TEST EQUIPMENT

SPECIFICATIONS

Ranges: Accuracy: 30/300mA: 0-200A: 200-250A: 250-300A: Circuit Voltage: Jaw Capability: Display: Data Hold: Operating Temp.: Storage Temp.: Battery: Dimensions: Safety:


Fluke Leakage Clamp Meter • Measure leakage current with 1 µA resolution, for monitoring of insulation erosion • Measure to 60 A, for general installation needs • Perform tests without powering down the installation or disconnecting equipment • Advanced shielding ensures accurate results when measuring near other conductors • Easy-to-carry, pocket-sized clamp with 40 mm (1.5") jaw size • Handy “Display-Hold” button for capturing readings in hard-to-reach places • Auto power-off, with warning buzzer, saves battery life • Meets safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances

SPECIFICATIONS Ranges: Resolution: Accuracy: (50/60 Hz) Frequency range: Maximum current: Digital display: Bargraph display: Measurement cycle: Range switching: Environment: Temperature coefficient: Influence of external magnetic field: Influence of conductor position: Circuit voltage: Safety standard: Battery type: Battery life: Conductor diameter Dimensions:

L

360

ORDERING INFORMATION Fluke-360

NEW 3 ma, 30 mA, 30 A, 60 A 0.001 mA, 0.01 mA, 0.01 A, 0.1 A ± 1% rdg ± 5d (≤50 A) ± 5% rdg ± 5d (>50 A) 15-150 Hz 60 A rms 3200 count LCD 32 segment LCD 2/sec. (digital display), 12 /sec. (bargraph display) Auto-range 0-50 °C, <80 % RH (non-condensing) <0.05 % of range/°C (0-18 °C & 28-50 °C, <50 A) 0.0005 % typical (on current value of adjacent cable) Within accuracy ≤ 300 Vrms EN 61010-1, EN 61010-2-032. 300 V CAT II, Pollution Degree 2 3 V Lithium battery (CR2032) Approx. 90 hours (continuous use) 40 mm (1.57") max. 176 x 70 x 25 mm (6.9" x 2.8" x 1")

Leakage Current Clamp Meter

Hioki AC Power Monitors Clamp-On Power HiTester

TEST EQUIPMENT

• Measure up to two 3Ø, 3-wire systems • Measure up to four 1Ø, 2-wire systems • 5A to 5000A range • Simultaneous recording of demand values and harmonics • Ideal for troubleshooting & energy management

3169 SPECIFICATIONS Systems: Functions: Ranges:

3169

L

Power:

1Ø 2-wire, 1Ø 3-wire, 3Ø 3-wire, 3Ø 4-wire (50/60 Hz) ACV, ACA, W, VA, VAr, PF, integrated power, Frequency, Harmonics 150/300/600V With 9660: 5-100A, 4 ranges With 9661: 5-500A, 5 ranges With 9669: 100A-1kA, 3 ranges With 9667: 500A-5kA, 2 ranges With 9694: 0.5A-5A, 3 ranges 75W to 9MW, 108 combination patterns

Power Quality Analyzer • Measure Dips, Swells, Interruptions, Flicker, Transients • Harmonic to the 50th order • High frequency transient over voltage • Detection and waveform display • 4 current and 4 voltage channels

ORDERING INFORMATION Order Clamp-on Sensor Separately HK/3169-20 Clamp-On Power HiTester, with voltage leads HK/3196 Power Quality Analyzer, with voltage leads HK/9660 100A Clamp-On Sensor HK/9661 500A Clamp-On Sensor HK/9669 1000A Clamp-On Sensor HK/9667 5000A Flexible Clamp-On Sensor HK/9694 5A Clamp-On Sensor Other Options: Printer, memory cards, PC software, carrying case

147

Accuracy:

±0.2% rdg ±0.1% f.s. + Clamp accuracy (for active power) With 9660: ±0.3% rdg ±0.02% FS With 9661: ±0.3% rdg ±0.01% FS With 9669: ±1.0% rdg ±0.01% FS With 9667: ±2.0% rdg ±1.5 mV With 9694: ±0.3% rdg ±0.02% FS Harmonics: Up to the 50th order, ±3% FS + measurement accuracy Power: 100 to 240VAC, 50/60 Hz Dimensions: 8.3"W x 6.3H x 2.4"D

3196 SPECIFICATIONS Systems: Ranges:

3196

L

1Ø 2-wire, 1Ø 3-wire, 3Ø 3-wire, 3Ø 4-wire (50/60 Hz) Ch1, Ch2, Ch3: 150/300/600V AC Ch4: 60/150/300/600V AC, 60/600V DC 9660: 50/100A, 9661: 50/500A, 9667: 500/5000A, 9669: 1000A Measurements: 1. Transient overvoltage 2. Voltage swell, Voltage dip, Voltage interruption 3. Frequency, Voltage, Current, Voltage/Current peak, Active/Reactive /Apparent power, Power factor, DPF 4. Voltage unbalance ratio, Current unbalance ratio 5. Harmonic voltage/current/power, Inter harmonic voltage/current, Harmonic voltage current phase angle, Total harmonic/inter harmonic distortion 6. IEC flicker[Pst, Plt], K factor / ∆V10(Japan) Internal Memory: 13MB Interface: Flash ATA card (up to 528MB), RS-232C, LAN (10BASE-T), HTTP server function Power: Rechargeable battery & AC adapter Dimensions: 11.8"W x 8.5"H x 2.7"D


Yokogawa Clamp-on Power Monitors/Analyzers

CW121 Clamp-on Power Monitor

For maintenance and long term monitoring of electrical equipment and systems. • Supports 1Ø 2W to 3Ø 4W systems • Internal flash card memory • RS-232 or RS-485 communications • Sends data to internal memory, PC, optional floppy disk or printer • Compact and light weight unit

SPECIFICATIONS Voltage: Current: Measurement Parameters: Accuracy: Record Time: Flash Memory: External I/O: Data Accumulation: Wiring Error Check: Communications: Display: Safety: Dimensions: Power:

150, 300, 450 ACV 20 - 3000 ACA V, A, VAR, PF, Hz, Wh ±0.8% rdg ± 0.4% rng, depending on clamp probe Settable from 1-30 sec., 1-30 min., 1 hr. Compatible up to 128 MB flash card One of three options for start / stop Wh 24 hours of data in one second intervals Function ensures correct measurement operations RS-232 standard, RS-485 available Large backlit LCD UL approved 4.6"W x 6.4"H x 2.0"D (117x161x51mm) 100 - 240V AC, 50/60Hz (CAT II)

CW240 Clamp-on Power Analyzer

Records electric energy measurements, instantaneous measurements, demand measurements, waveform measurements, voltage fluctuation measurements, harmonics measurements and leakage current. • Supports 1Ø 2W to 3Ø 4W 4i (neutral line current) systems • Supports two system measurements (1Ø 2W X2) (1Ø 3W X2) (3Ø 3W X2) • Data logging interval up to 1 hour • Internal flash card memory system • RS-232 or RS-485 communications • Sends data to internal memory, PC, optional floppy disk or printer

SPECIFICATIONS Voltage: Current: Measurement Parameters: Record Time: Flash Memory: Harmonic Measurement: Wiring Error Check: Communications: Display: Safety: Operating temperature: Dimensions: Power: Location:

150, 300, 600, 1000 ACV 200.0 ACmA - 3000 ACA V, A, VAR, PF, HZ, WATTS, VA, PA 1 cycle- 0.5 sec., 1-30 sec., 1-60 min . Compatible up to 512 MB flash card up to 50th Function ensures correct measurement operations RS-232 standard, RS-485 available Large backlit LCD UL approved 5-40°C, 5-80% RH (no condensation) 8.11"W x 7.25"H x 2.56"D (206 x 184 x 65mm) 100 - 240V AC, 50/60Hz (CAT II) Indoor use

ORDERING INFORMATION ORDERING INFORMATION Clamp-on Power Monitor with complete accessory package Includes all required hardware and software, except clamp-on current probes: Portable Clamp-on Power Meter, UL/CSA standard power cord, four voltage probes, RS-232 communications, 9 pin RS232 communication cable, 16 MB flash memory card and card holder, flash card reader and cable, power cable. (Supplies power from measured circuit), magnetic case for power meter, carrying case for power meter and accessories, data analysis software package. Add suffix to part number for correct size Current Clamp-on Probes: /C2 Clamp-on Probes for 20/200A (3pcs / set) /C4 Clamp-on Probes for 500A (3pcs / set) /C6 Clamp-on Probes for 700A (3pcs / set) /C8 Clamp-on Probes for 50A (3pcs / set) /96034 Clamp-on Probe for 3000A Jaw type /96035 Clamp-on Probe for 3000A Flexible type

148

TEST EQUIPMENT

YE/CW121-D-1/SP1

YE/CW240-D/DA/PMI/SPI Clamp-on Power Analyzer with complete accessory package. Includes all required hardware and software, except clamp-on current probes (see below): UL/CSA standard power cord, four voltage probes, NiMH battery pack & six AA alkaline batteries, carrying case, 16 MB flash card and card reader, 9 pin RS-232 cable and Toolbox software package, users manual, quick manual, communications manual. Add suffix to part number for correct size Current Clamp-on Probes: /C2 Clamp-on Probes for 20/200A (4 pcs / set) /C4 Clamp-on Probes for 500A (4 pcs / set) /C6 Clamp-on Probes for 700A (4 pcs / set) /C8 Clamp-on Probes for 50A (4 pcs / set) /C10 Clamp-on Probes for 2A (4 pcs / set) /C12 Clamp-on Probes for 3000A Jaw type (4 pcs / set) /C14 Clamp-on Probes for 3000A Flexible type (4 pcs / set) /96036 Clamp-on Probe for 2A measurement Optional AP240E Data analysis software package


Hioki Power Quality Analyzer Catch power quality problems on the fly.

Includes: voltage cord set, 6 hour battery pack (rechargeable), AC adapter, USB cable, basic PC software, carrying case & strap. Order current sensors separately.

SPECIFICATIONS

• Monitor Inrush Current, Voltage Swells, Voltage Dips, Transient Over-Voltage, Interruptions • Measure and Record: Power and Power Factor, Active/Reactive Energy, Demand, Load Changes (with graph display), Voltage and Current • Large 4.7" Color LCD with Backlight

Measurement lines:

L

3197

& three 9661 sensors

ORDERING INFORMATION HK/3197 HK/9660 HK/9661 HK/9667 HK/9669 HK/9694 HK/9624-50

Power Quality Analyzer 100A Clamp-on Sensor (300V, Ø15mm jaw) 500A Clamp-on Sensor (300V, Ø46mm jaw) 5000A Flexible Clamp-on Sensor (1000V, Ø254mm jaw) 1000A Clamp-on Sensor (600V, Ø55mm jaw) 5A Clamp-on Sensor (300V, Ø15mm jaw) Deluxe PQA Analysis Software

Single-phase 2-wire (1P2W), single-phase 3-wire (1P3W), three-phase 3-wire (3P3W2M & 3P3W3M), three-phase four-wire (3P4W and 3P4W2.5E) Measurement line frequency: Auto-detect (50Hz/60Hz) Voltage range: 600.0V AC (crest factor 2 or less) Current ranges: 500.0mA, 5.000A, 50.00A, 10.00A, 100.0A, 500.0A, 1.000kA, 5.000 kA (manually switchable in 2 range sets according to clamp sensor Measurement items: Impulsive voltage quality: Transient overvoltage (Impulse) RMS voltage quality: Voltage swell, Voltage dips, Voltage interruption Power quality: Frequency, Voltage, Current, Current peak, Active/Reactive/Apparent power, Power factor (displaced power factor) Three phase quality: Voltage unbalance ratio, Current unbalance ratio Harmonic quality: Harmonic voltage, Harmonic current, (to 50th harmonic) Harmonic power, Harmonic voltage/current phase angle, Total harmonic voltage distortion, Total har monic current distortion (THD-F, THD-R), Measurement method: Simultaneous digital sampling of voltage and current (sampling frequency 10.24 kHz per channel) Interval settings: Auto / 1 / 5 / 10 / 15 / 30 / 60 minutes Recordable period: 125 days maximum; partition memory into four segments for maximum 31 days of recording each Internal memory: 4 MB non-volatile PC Interface: USB 2.0 Dimensions: 5.1"W x 9.7"H x 2.5"D (128 x 246x 63 mm)

Hioki AC/DC Current Monitor Includes: carry strap, 4 AA batteries. Order clamp-on sensor separately.

L

SPECIFICATIONS

TEST EQUIPMENT

3290

Choice of measurement mode: DC (for battery measurement) AC+DC RMS (for full-/half-wave rectification measurement) AC RMS (for current distortion measurement) PEAK (for peak value measurement of inrush current, etc.) • Selectable recorder output and response time • Current integral, operating time/duty measurements (3290-10)

ORDERING INFORMATION HK/3290 HK/3290-10 HK/9691 HK/9692 HK/9693 HK/9445-02 HK/9400

149

Clamp-On AC/DC HiTester Deluxe Clamp-On AC/DC HiTester 100A AC/DC Clamp-on Sensor (600V, Ø35 mm jaw) 200A AC/DC Clamp-on Sensor (600V, Ø33 mm jaw) 2000A AC/DC Clamp-on Sensor (600V, Ø55 mm jaw) AC Adapter Carrying Case

Current measurement: AC RMS, AC MEAN, AC+DC, DC Current ranges: 20 to 100A with 9661 clamp 20 to 200A with 9662 clamp 200 to 2000A with 9663 clamp Frequency: 10 to 1000 Hz Analog outputs: DC or AC Current: 2V f.s. Level output with REC mode Waveform output with MON mode Integ./Frequency: 1V/f.s. Accuracy: Current: ± 1.3 % rdg. ± 3 digits. (typical) Frequency: ± 0.3 % rdg. ± 1 dgt. (typical at 50/60Hz) Frequency response: ± 2.3 % rdg. ± 8 dgt. (DC to 1 kHz) Digital display: 4 digit, maximum 3000 counts (9999 counts on 3290-10) Bar display: 20 segments Sampling rate: Fast: 4 times / sec (3290-10: 10times/sec), Normal: 2 times / sec, Slow: 1 time / 3sec Crest factor: 2.5 or less Max. circuit voltage: 600 V AC rms. (insulated wire) Dimensions: 6.1"W x 3.6"H x 1.9"D (155 x 98 x 47 mm) 3290-10: Polarity specific integral function measures battery charging and discharging. Peak current display shows peak charge and discharge.


AEMC Three-Phase Power Quality Analyzers

L

PowerPad™ 3945B

SPECIFICATIONS Electrical Sampling Frequency Data Storage

256 samples/cycle 3945B: 4MB 8335: 2GB SD card 3945B: 960V Ø-Ø, 480V Ø-N 8335: 10-1000V Ø-Ø & Ø-N MN Clamp: 5mA to 100mA/120A or 2 to 240A MR Clamp: 10 to 1000Aac, 10 to 1400Adc SR Clamp: 3 to 1200A AmpFlex™: 10 to 6500A (Crest factor at 6500 = 1) 40 to 69Hz kW, kVAR, kWh, kVARh, kVAh, K-Factor, Flicker 3945B: PF, DPF 8335: INrush 1st to 50th, Direction, Sequence 9.6V NiMH rechargeable battery pack AC Supply: 110/230VAC ±20% (50/60Hz) ≥8 hrs with display on; ≥35 hours with display off (record mode)

Voltage (TRMS) Current (TRMS)

Frequency Other Measurements

Harmonics Power Source Battery Life Mechanical Communication Display Dimensions Weight Safety Rating

All models include three color-coded current probes with 10 ft leads (MN93 example shown), four* color-coded 10 ft voltage leads, four* color-coded alligator clips, RS-232 DB9F optically coupled serial cable, NiMH battery, US 120V power cord, DataView ® software, carrying bag, soft carrying pouch and user manual. *Five in 8335 Kits

ORDERING INFORMATION AE/2130.75 AE/2130.76 AE/2130.77 AE/2130.78 AE/2130.79 AE/2130.80 AE/2136.21 AE/2136.22 AE/2136.23 AE/2136.24 AE/2136.25 AE/2136.26

PowerPad Model 3945B w/MN93 (240A) PowerPad ™ Model 3945B w/SR193 (1200A) PowerPad ™ Model 3945B w/24" AmpFlex™ 193-24 (6500A) PowerPad ™ Model 3945B w/36" AmpFlex™ 193-36 (6500A) PowerPad ™ Model 3945B w/MR193 (1000AAC/1400ADC) PowerPad ™ Model 3945B w/MN193 (6A/120AAC) PowerPad® Model 8335 w/MN93 (240A) PowerPad® Model 8335 w/SR193 (1200A) PowerPad® Model 8335 w/24" AmpFlex® 193-24 (6500A) PowerPad® Model 8335 w/36" AmpFlex® 193-36 (6500A) PowerPad® Model 8335 w/MR193 (1000AAC/1400ADC) PowerPad® Model 8335 w/MN193 (5A/120AAC)

Accessories (Optional) AE/2140.14 Set of three color-coded MN193 probes (6A/120A) with 10 ft leads AE/2140.17 5A Adapter box AE/2140.61 Set of four color-coded 30 ft voltage leads AE/2140.24 Set of three color-coded MN93-30 probes (240A) with 30 ft leads AE/2140.25 Set of three color-coded SR193-30 probes (1200A) with 30 ft leads AE/2140.26 Set of three color-coded 24" AmpFlex™ 193-24-30 probes (6500A) with 30 ft leads AE/2140.27 Set of three color-coded 36" AmpFlex™ 193-36-30 probes (6500A) with 30 ft leads AE/2140.28 One AC/DC Current Probe Model MR193-BK (black connector) (1000AAC/1400ADC) AE/2140.29 Set of three color-coded MN193-30 probes (6A/120A) with 30 ft leads AE/2140.30 Set of three color-coded MR193-30 probes (1000AAC/1400ADC) with 30 ft leads

150

TEST EQUIPMENT

Port Optically coupled RS-232 1/4 VGA (320 x 240) color LCD 9.5 x 7 x 2" (240 x 180 x 55mm) 4.6 lbs (2.1 kg) 3945B: 600V CAT III 8335: 1000V, CAT IV

•True RMS single-, two- and three-phase measurements at 256 samples/cycle, plus DC •Real-time color waveforms •Easy-to-use on-screen setup •Automatic current probe recognition and scaling •True RMS voltage and current measurement •Measures DC volts, amps and power •Display and capture voltage, current and power harmonics to 50th order, including direction, in real time •Capture transients down to 1/256th of a cycle •Phasor diagram display •VA, VAR and W per phase and total •kVAh, VARh and kWh per phase and total •Neutral current display for three-phase •Transformer K-factor display •Power Factor, displacement PF display •Captures up to 50 transients •Short-term flicker display •Phase unbalance (current and voltage) •Harmonic Distortion (total and individual) from 1st to 50th •Alarms, surges and sags •Screen snapshot function captures waveforms or other information on the display ® •Includes DataView software for data storage, real-time display, analysis and report generation


AEMC Single-Phase Power Quality Analyzer • Stores up to eight screen captures • Stores up to 1MB of trend recorded data • Configurable from DataView® software or front panel • Captures up to 4096 alarm events using up to 10 different thresholds • Displays and records up to 17 different power quality parameters • Includes DataView® software for data storage, real-time waveform display, analysis and report generation

• Displays Min, Max and Average Volts and Amps, Crest Factor, Peak value and K-Factor • Calculates and displays Watts, VARs and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase • Displays total harmonic distortion (THD-F and THD-R) for voltage and current • Displays individual harmonic values and % for Volts and Amps through the 50th harmonic • Captures, displays and stores inrush current waveforms and statistics

8230 PowerPad®Jr.

All models include current probe with 10 ft lead and black connector, black & red 10 ft voltage leads and alligator clips, optical USB cable, NiMH battery, US 120V power cord, DataView® software, carrying bag, soft carrying pouch and user manual.

M

Dat aV iew® Sof tware included with Model 8230 • Display and analyze real-time or recorded data on the PC • Configure all PowerPad® Jr. functions & parameters • Customize views, templates and reports • Create and store a complete library of configurations • Zoom in and out and pan through sections of the graph • Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs & stored alarms

ORDERING INFORMATION AE/2130.82 AE/2130.83 AE/2130.84 AE/2130.85 AE/2130.86 AE/2130.87

PowerPad® Jr. Model 8230 w/MN93-BK (240A) PowerPad® Jr. Model 8230 w/SR193-BK (1200A) PowerPad® Jr. Model 8230 w/24" AmpFlex® 193-24-BK (6500A) PowerPad® Jr. Model 8230 w/36" AmpFlex® 193-36-BK (6500A) PowerPad® Jr. Model 8230 w/MR193-BK (1000AAC/1400ADC) PowerPad® Jr. Model 8230 w/MN193-BK (6A/120AAC)

SPECIFICATIONS Electrical Voltage (TRMS) Current (TRMS)

Frequency Other Measurements Harmonics Sampling Frequency Data Storage Power Source Battery Life Mechanical Communication Port Display Dimensions Safety Rating

660V Phase-to-Phase, 600V Phase-to-Neutral MN Clamp: 5mA to 120A or 2 to 240A MR Clamp: 10 to 1000AAC, 10 to 1400ADC SR Clamp: 3 to 1200A AmpFlex®: 10 to 6500A (Crest factor at 6500 = 1) 40 to 70Hz kW, kVAR, PF, DPF, kWh, kVARh, kVAh, K-Factor, Flicker, Harmonic Phase Shift, Phase Rotation THD-R, THD-F, V, A, VA 1st to 50th, Direction, Sequence 256 samples/cycle 1.5MB partitioned for waveforms, alarms & trend NiMH AA rechargeable battery pack AC Supply: 120/230VAC (50/60Hz) >Eight hrs with display on, >40 hrs with display off (recording mode) Optically isolated USB 1/4 VGA (320 x 240) color LCD 8.3 x 4.3 x 2.4" (211 x 108 x 60mm) EN 61010, 600V Cat. III, Pollution Degree 2

AEMC Power Quality Meter

TEST EQUIPMENT

• Displays Min, Max and Average Volts and Amps, Crest Factor, Peak value and K-Factor • Calculates and displays Watts, VARs and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase • Displays total harmonic distortion (THD-F and THD-R) for voltage and current • Displays individual harmonic values and % for Volts and Amps through the 50th harmonic • Captures and displays inrush current • Calculates & displays phase rotation & RPM All models include current probe with 10 ft lead & black connector, black & red 10 ft voltage leads and alligator clips, optical USB cable, six 1.5V batteries, two safety 8220 test probes, DataView® software, carrying bag, soft carrying pouch and user manual.

M

Three-line backlit digital display with custom icons

ORDERING INFORMATION AE/2130.91 AE/2130.92 AE/2130.93 AE/2130.94 AE/2130.95 AE/2130.96

151

Power Quality Meter Model 8220 w/MN93-BK (240A) Power Quality Meter Model 8220 w/SR193-BK (1200A) Power Quality Meter Model 8220 w/24" AmpFlex® 193-24-BK (6500A) Power Quality Meter Model 8220 w/36" AmpFlex® 193-36-BK (6500A) Power Quality Meter Model 8220 w/MR193-BK (1000AAC/1400ADC) Power Quality Meter Model 8220 w/MN193-BK (6A/120AAC)

• Displays °F or °C & resistance to 2000Ω • Conducts continuity and diode tests • Stores up to nine complete sets of readings for all volt, amp, power, harmonics and other measurements • Configurable from DataView® software or front panel • Operates off batteries or optional AC adapter • Includes DataView® software for data storage, real-time waveform display, analysis and report generation

SPECIFICATIONS Voltage (TRMS) Current (TRMS)

Frequency Other Measurements Sampling Frequency Data Storage Power Source Communication Port Dimensions

660V Phase-to-Phase, 600V Phase-to-Neutral MN Clamp: 5mA to 120A or 2 to 240A MR Clamp: 10 to 1000AAC, 10 to 1400ADC SR Clamp: 3 to 1200A AmpFlex®: 10 to 6500A (Crest factor at 6500 = 1) 40 to 70Hz kW, kVAR, PF, DPF, VA, Harmonics, Phase Rotation, Temperature, RPM, Resistance, Continuity, Diode Test 256 samples/cycle Stores nine sets of readings Six 1.5V AA Alkaline batteries (>8hr life with display on) AC Supply: 120/230VAC (50/60Hz) – optional Optically isolated USB 8.3 x 4.3 x 2.4" (211 x 108 x 60mm)


Fluke Three Phase Power Quality Analyzers The Fluke 435 and 434 three-phase power quality analyzers help locate, predict, prevent and troubleshoot problems in threephase and single-phase power distribution systems. The new IEC standards for flicker, harmonics and power quality are built in. • Analyzer trends using cursor & zoom tools even while background recording • Seven hours operating time per charge on NiMH battery pack •Transfer data files to your PC for reporting and analysis using FlukeView® software

435 Includes: Hard carrying case with rollers, four flexible current probes (i430flex), five test leads and clips, battery charger, FlukeView software, Power Log software, optical USB cable, color localization set, Getting Started manual, Users manual. 434 Includes: Hard carrying case, four current probes (i400s), five test leads and clips, battery charger, FlukeView software, optical USB cable, color localization set, Getting Started manual, Users manual.

Feature

ORDERING INFORMATION 3Ø Power Quality Analyzer 3Ø Power Quality Analyzer

434

SPECIFICATIONS System Configuration

• Automatic transient capture: never miss an event • Auto Trends: don't waste time setting up recordings

3 Year warranty Fluke 435 Fluke 434

435

Measure voltage, current, dips, swells, interruptions, harmonics, inter-harmonics, flicker, power, energy, transients, frequency, unbalance, inrush, EN50160 overview Logger function with multiple parameters Optional* Mains signalling Optional* Current probes 3000A flexible (4) 40/400A clamp (4) Memory 16MB 8MB Software Power Log & FlukeView FlukeView IEC61000-4-30 Class A compliance Safety rating CAT IV 600 V/CAT III 1000 V Battery life Up to 7 hours/charge *Optional function can be added with upgrade kit.

• Four voltage and four current channels capture waveform data on all phases simultaneously • Meter display of phase readings

Voltage Inputs Maximum Bandwidth Accuracy (ac+dc) Current Inputs Range Nominal Frequency Accuracy (ac+dc) Watts (VA, VAR) Accuracy Sampling Logger Function Display Power

1Ø+neutral, 1Ø split phase, 1Ø IT no neutral, 3Ø WYE, 3Ø Δ, 3Ø IT, 3Ø hi leg, 3Ø open leg, 3Ø 2-element, 3Ø 2½-element Four (3 phases + neutral), dc coupled 1000V rms, 6kV maximum peak measured >10kHz, up to 100kHz for transient display 435: ±0.1% of nominal voltage, 434: ±0.5% of nominal Four ((3 phases + neutral), dc coupled Determined by clamp-on probes used 40-70Hz, BW >10kHz 435: ±0.5%±20d, 434: ±1%±5d (with supplied probes) 1.0-20.00MW (resolution 0.1 to 1 kW) 435: ±1%±10d, 434: ±1.5%±10d 16 bit resolution. 200k samples/second max Captures up to 10000 events, 100 parameters/phase 4.5" x 3.4" Color LCD, 320x240 pixel 115/230V ac or battery, built-in battery charger

Fluke Power Quality Analyzer • Voltage, current and power harmonics up to 51st • Total harmonic distortion (THD) • Phase angle of individual harmonics • Watts, power factor, displacement power factor, VA and VAR • Voltage and current waveforms • Calculates 3Ø Power on Balanced Load from 1Ø Measurement • Use cursors to read time and date of sags and swells. • Catch voltage transients and waveform distortion • See current at the instant of voltage events • Catch and save up to 40 transients • Correlate the cause of distortion with time and date stamps • 3 Year Warranty

The Fluke 43B includes a hard case, voltage and current probes, FlukeView® PC software and cable, line voltage adapter/battery charger, applications manual, power quality video and user’s manuals.

ORDERING INFORMATION Fluke 43B

151a

Power Quality Analyzer

The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures. All in a rugged handheld package.

Function

Measurement

Accuracy/Selection

Volts Amps Mains Frequency Watts, VAR, VA PF, DPF Sags & Swells Transient Capture

5.000V-600V RMS (AC & DC) 50.00A-50.00kA RMS (AC & DC) 40.0-70.0Hz 250W-2.5MW 0.25-1.00 Voltage and Current 40 ns pulse width Up to 40 transients 1A to 1000A 500.0Ω to 30.00MΩ 50.00nF to 500.0μF Dc, ac, ac+dc, peak, peak-peak, Hz, duty cycle, phase, pulse width, crest factor All functions V/A/Hz, Power, Harmonics, Ω/Cap, Temperature, Scope

±(1%+10d) ±(0.5%+2d) ±(4%+4d) ±0.04 4 min-16 days selectable Select 20/50/100/200% above or below line voltage 1s to 5 min selectable ±(0.6%+5d) ±(2%+10d) Sampling rate: 25MS/sec Bandwidth: Voltage BW (Channel 1): 20MHz Current BW (Channel 2): 15kHz 10 screens 4 min-16 days selectable parameters in each display mode

Thrush Current Ohms Capacitance Scope

Screen Saves Recording

Battery life: Rechargeable Ni-Cd pack (charger included), 6 hrs typical (continuous)

OPTIONAL ACCESSORIES i200s 80i-1000s i2000flex 80TK 80T-IR PAC91

240A AC current probe 1000A AC current probe 2000A flexible AC current probe Thermocouple module Non-contact infrared temperature probe Parallel printer adapter


Extech Infrared Thermometers Mini IR Thermometers

High Temperature IR Thermometer

Compact thermometers with choice of 500°F or 1200°F maximum reading • Model 42500 measures -4 to 500°F (-20 to 260°C) with 1° resolution • Model 42510A measures --25 to 1200°F (-50 to 650°C) with 0.1° resolution up to 1000° • Built-in laser pointer and backlit LCD display • Adjustable emissivity (42510A) • Field of view: 42500 6:1, 42510A 12:1 • Complete with 9V battery and carrying case

Measures surface temperature to 1832°F with 50:1 distance to target ratio • Measures small surface areas at greater distances • Adjustable emissivity increases accuracy for different surfaces • Displays MAX, MIN, average and difference (MAX-MIN) values • Audible high/low alarm alerts user when temperature exceeds set limits • Large, backlit LCD display with automatic Data Hold feature • Complete with 9V battery and hard carrying case

L Model 42510A

IR Thermometer with Wireless PC Interface

Dual Laser IR Thermometers Two laser pointers converge to 1" target spot • Measure to 1800°F (1000°C) with 1° resolution • 12" or 30" laser convergence distance • Fast 0.15 second response time • White backlit dual LCD display • Adjustable emissivity increases accuracy • Lock function for continuous readings • Adjustable high/low setpoints with audible alarm alerts • Complete with 9V battery and carrying case

L Model 42545

L Model 42512

ORDERING INFORMATION 500° Mini IR Thermometer

EX/42510A

1200° Mini IR Thermometer

EX/42511

Dual Laser IR Thermometer - 12" Convergence

EX/42512

Dual Laser IR Thermometer - 30" Convergence

EX/42545

High Temperature IR Thermometer IR Thermometer with Wireless PC Interface

EX/IR201

Pocket IR Thermometer

L Model 42560

Pocket IR Thermometer

EX/42500

EX/42560

Wireless USB interface transmits temperature data to a PC • Wide range (-58 to 1922°F / -50 to 1050°C) • High 30:1 distance to target ratio • Manual or Automatic emissivity • Type K probe for accurate measurements on different surfaces • Transmit continuous readings to the remote receiver with PC connection via USB CABLE • Complete with transmitter base, receiver with USB cable, type K probe, PC soft ware, 9V battery, AC adapter & case Handy troubleshooting thermometer with Laser pointer • Measures from -58°F to 518°F (-50° to 270°C) • Built-in laser pointer to improve aim • Fixed emissivity (0.95) covers 90% of surface applications • 6:1 field of view • Complete with two AAA batteries and carrying case

L Model IR201

Model Temperature: (non-contact) Temperature (Type K):

42500 -4 to 500°F -20 to 260°C —-

42510A -25 to 1200°F -50 to 650°C —-

42511 -58 to 1100°F -50 to 600°C —-

42512 -58 to 1832°F -50 to 1000°C —-

425 45 -58 to 1832°F -50 to 1000°C —-

Basic Accuracy: (non-contact)

±2.5% of reading or ±4°F / 2°C

±1% of reading ± 2°F / 1°C

±1% of reading ± 2°F / 1°C

±1% of reading ± 2°F / 1°C

±2% of reading ±4°F / 2°C <932°F (500°C)

(whichever is greater)

1° 0.95 fixed 6:1

0.1° up to 999.9° 0.1° 0.1-1.00 adjust 0.1-1.00 adjust 12:1 12:1

0.1° 0.1-1.00 adjust 30:1

0.1° up to 199.9° 0.1-1.00 adjust 50:1

0.1° 0.1-1.00 adjust 30:1

1° 0.95 fixed 6:1

3.2 x 1.7 x 6.7" 82x44x170mm 4.9oz (140g) 3 years

3.2 x 1.6 x 6.3" 82x42x160mm 6.4oz (180g) 3 years

5.7 x 4.1 x 1.6" 146x104x43mm 5.7oz (163g) 3 years

3.9 x 2.2 x 9" 100x56x230mm 10.2oz (290g) 3 years

3.9 x 2.2 x 9" 100x56x230mm 10.2oz (290g) 3 years

3.7 x 2 x 1" 94x51x25mm 2.7oz (76g) 1 year

(whichever is greater)

Max. Resolution: Emissivity Field of View: (Distance to Target) Dimensions: Weight Warranty:

5.7 x 4.1 x 1.6" 146x104x43mm 5.7oz (163g) 3 years

42560 -58 to 1922°F -50 to 1050°C -58 to 2498°F -50 to 1370°C ±2% of reading or ±4°F / 2°C

IR201 -58 to 518°F -50 to 270°C —±2.5% of rdg ±3°F / 2°C

152

TEST EQUIPMENT

SPECIFICATIONS


Yokogawa Insulation Testers 2406E Analog Insulation Tester

Model

• 3 Ranges • Discharge Function • Portable Case for Hanging Tester from Neck • Sky-Blue EL Illumination

Rating 31 41 32 42

L

33

2406E

YE/2406

43 34

MY10 Analog Insulation Tester

44

• Single Range Models • AC Voltage Measurement Function (needle and LED) • Automatic Discharge Function (LED) • Easy to Use Pull-Up Switch

35 45

MY10

01 02 YE/MY10 03 04 05

L

YE/MY40 01

MY40 Digital Insulation Tester • Four Voltage Ranges • Memory Function • Comparator Function with Sound Alert • Auto Discharge Function • Large LCD Display with Stable Indication • AC Voltage/Resistance Measuring Functions • Conductor Resistance MY40 Measurement

Measure

50V / 10M 125V / 20M 125V / 20M 250V / 50M 125V / 20M 250V / 50M 500V / 100M 250V / 50M 500V / 100M 1000V / 2000M 250V / 500M 500V / 1000M 1000V / 2000M

Display

Illumination

Analog Meter

Back-lit EL display (41/42/43/44/45)

Analog Meter

Phosphorescent scale

3.5 digit & 400Ω

LED Lighting bargraph LCD

300V AC

600V AC

125V / 20M 250V / 50M 500V / 100M 500V / 1000M 1000V / 2000M 125V / 200M 250V / 200M 500V / 2000M 1000V / 2000M

250VAC 300VAC 500VAC 600VAC

Lifetime Warranty on All Models Dimensions: 2406 MY10, MY40

4.7"x4.3"x2.4" (120x110x60mm) 4.9"x4.1"x2.1" (125x103x53mm)

2406 MY10, MY40

6 AA Batteries (included) 4 AA Batteries (included)

Power:

L

SPECIFICATIONS MODEL

L

• Single dot laser sighting • Pistol Grip housing • 1% / 1°C accuracy • Dual backlit display • Reading hold • Protective rubber boot

L

TEST EQUIPMENT

Fluke Infrared Thermometers

Fluke 62

Fluke 68

ORDERING INFORMATION Fluke 62 Fluke 63 Fluke 66 Fluke 68 Fluke 68IS FL/H6

153

Mini Infrared Thermometer w/ holster Infrared Thermometer w/ holster & case Infrared Thermometer w/ holster & case Infrared Thermometer w/ holster & case Intrinsically safe Infrared Thermometer w/ case Holster

62

63

66

68

Range °C

-30 to 500

-32 to 535

-32 to 600

-25 to 760

Range °F

-25 to 1400

-20 to 932

-25 to 999

-25 to 1100

Spot Distance

10:1

12:1

30:1

50:1

Emissivity

0.95

0.95

0.10-1.00

0.10-1.00

Min/Max/Avg

Max

Max

All

All

Datalogging

--

--

12 point

12 point

Hi/Lo Alarms

--

Yes

Yes

Yes

RTD probe*

--

--

Yes

Yes

Warranty

2 yr

1 yr

1yr

1yr

Response Time:

<500 mS

Battery: Size:

9V alkaline (included) 62: 6x4x1.5" (152x101x38mm) 63, 66, 68: 8x6x2" (200x160x55mm)

Operating Temp:

0 to 50°C, <90% RH non-condensing

*contact temperature measurement with option RTD probe


Yokogawa Thermometers TM10 Thermistor Data Collecting Thermometer

TM20 TC Data Collecting Thermometer • Two Channel Simultaneous Measurement • Measure Type K/J/E/T Thermocouples, mV Inputs & Infra-Red Sensors • Display Channel Readings, Min, Max, Average & Difference

• Switch Between External Probe, Infra-Red Sensor and Built-In Sensor • Measure from -30 to 200°C

TX10 Series • Measure J/K/T/E Thermocouples • 3 1/2 Digit Display for Resolution to 0.1°C • IP54 Drip Proof Case • Two Channel Measurement (TX10-03) • 10 Measurement Storage (TX10-02/03) • Min & Max Storage (TX10-02/03) • Temperature Difference Display (TX10-03)

SPECIFICATIONS TM10

TM20

TX10

Range

-30 to 200°C (-22 to 392°F)

TC same as TM20

Accuracy

±0.3°C (0-100°C)

Resolution

0.1°C

Operating Temp

-20 to 50°C

K -200 to 1372°C (-328 to 2501°F) J 200 to 1000°C (-328 to 1832°F) E -200 to 700°C (-328 to 1292°F) T -200 to 400°C (-328 to 752°F) TC ±0.3% rdg ±0.3°C (>-100°C) V ±0.1% rdg ±0.2% range TC 0.1°C V 0.001V mV 0.1mV 0 to 50°C

±0.3% rdg ±0.7°C (-100 to 200°C) 0.1°C (below 200°C)

0 to 50°C

TM10 & TM20 Common Features • Backlit LCD Display • IP54 Drip Proof Case • 1 Second to 24 Hour Measuring Intervals • Data Capacity up to 20000 Readings • Hi/Lo Alarms • RS232 Port for PC Interfacing • Easy PC Data Management (Automatic Layout in Excel) Collector mode records the measured temperature along with the measured item, operator name, date/time of measurement in response to a key action. Test comments can also be recorded. Logging mode continuously records the measured temperature at a preset time interval.

ORDERING INDFORMATION YE/TM10 Thermistor Data Collecting Thermometer YE/TM20 TC Data Collecting Thermometer YE/TX10-01 Single function, 1 channel Thermometer YE/TX10-02 Multi-function, 1 channel Thermometer YE/TX10-03 Multi-function, 2 channel Thermometer Order probes and carrying case separately

ACCESSORIES TM10 Accessories YE/90010 150mm needle probe YE/90011 120mm sharp needle probe YE/90012 Surface probe YE/90013 Rounded probe (for liquids) YE/93010 Soft case TM10 & TM20 Accessories YE/90003 Non-contact probe YE/91011 RS-232 PC cable TX10 & TM20 Accessories YE/90020 Type K rounded probe YE/90023 Type K needle probe YE/90030 Type K surface probe YE/245907 Type K bead YE/93012 Soft case

153a


Hioki Megohm Testers

3455

• Insulation and low resistance modes – comparator, hold • Insulation resistance modes – auto discharge • All measurement modes – battery indicators • Live wire warning • Low resistance zero adjust

L

L

• Tests insulation on transformers, cables & motors • Calculates PI (Polarization Index) and DAR (Dielectic Absorption Ratio) • Temperature measurement & compensation • Step voltage testing • Leakage current display

3454-11

SPECIFICATIONS

SPECIFICATIONS Insulation Resistance: Test voltage: Manual adjust: Resistance: Leakage current: Voltage Measure: Temperature: PI, DAR test: Step voltage test: Compensation: Timer: Data memory: Energy discharge: Display LCD: Display Info: PC software: Power supply: Standards: Dimensions:

250V, 500V, 1kV, 2.5kV, 5kV DC 25V step (<1kV), 100V step (>1kV) 0.00MΩ - 5TΩ in 7 ranges (±5% rdg. ±5d for test current >100nA) 1.00nA-1.2mA in 6 ranges (±2.5% rdg. ±5d above100nA) 50-750V AC, 50/60Hz; 50-1000V DC (±5% rdg. ±5d) -10.0 to 70.0°C (±1.5°C) Times are user programmable. 500V-2.5kV in 500V steps, 1kV-5kV in 1kV steps Displays the resistance based on reference temperature. Compatible to 10 insulation materials 30s to 30min Manual recording: 100 data Interval recording: 360 times x 10 data Automatic discharge after measurement Digital and bargraph display, with backlight Time, date, test voltage, timer, battery level For USB data transfer and report editing 6 AA batteries CAT IV 600V, CAT III 1000V 10.2"W x 9.9"H x 4.7"D (260 x 251 x 119mm)

Insulation Resistance Test Voltage: 250 / 500 / 1000V DC Ranges: 4.000/40.00/400.0/500.0MΩ, 1000MΩ (1000V only) Accuracy: 1st effective range: ±3% rdg. ±4d Low Resistance Ranges: 40.00 / 400.0 / 4.000k / 40.00k / 400.0k / 4.000MΩ Accuracy: ±3% rdg. ±6d (±5% rdg. ±6d at 400kΩ or higher) AC Volts Measure Range: 0 to 750V, 50/60Hz Accuracy: ±3% rdg. ±6d (up to 600V) Live Wire Warning: >70V ±10V across terminals Power supply: 4 AA batteries Dimensions: 7.0"W x 5.3"H x 2.2"D

ORDERING INFORMATION HK/3455-01 HK/3454-11 HK/9288 HK/9289 HK/9257 HK/9631-01 HK/9750 HK/9459 HK/9753

5kV MΩ HiTester with 3m leads, USB cable, PC software 1kV MΩ HiTester with 1.2m leads Breaker pin for 3454-11 Test probes, alligator clips for 3454-11 Connection cord for 3454-11 Temperature sensor for 3455 (1m) 10m Test Leads for 3455 Rechargeable Battery pack for 3455 AC adapter for 3455

Fluke MegOhmMeters Handheld MegOhmMeter

ORDERING INFORMATION Fluke 1503 Fluke 1507 Fluke 1550B

1kV Handheld Insulation Resistance Tester Deluxe 1kV Handheld Insulation Resitance Tester 5kV MegOhmMeter

SPECIFICATIONS Insulation Resistance: 250V 200 kΩ – 50 GΩ 500V 200 kΩ – 100 GΩ 1000V 200 kΩ – 200 GΩ 2500V 200 kΩ – 500 GΩ 5000V 200 kΩ – 1 TΩ Step Size: 50V up to 1000V, then 100V Leakage Current: 1 nA – 2 mA Capacitance: 0.01 µF – 15.00 µF Timer: 0 – 99 minutes Power: 12V rechargeable battery Charger: 85-250VAC Operating Temperature: -20 to 50°C Includes test leads, 500V probes, alligator clips, interface adapter & cable, FlukeView® software, line cord & carrying case.

154

TEST EQUIPMENT

SPECIFICATIONS Insulation Resistance: Ranges: 0.01 MΩ to 10 GΩ (1507) 0.01 MΩ to 4000 MΩ (1503) Test Current: 1mA max. Test Voltage: 50, 100, 250, 500, 1000 V (500 & 1000 V on 1503) Basic Accuracy: ±(1.5% rdg + 5d) up to 2000 MΩ Resistance: 0.01 Ω to 20.00 kΩ Basic Accuracy: ±(1.5% rdg + 3d) Voltage: 0 – 600.0 V DC or AC (50-400Hz) Live Circuit Indicator: Inhibits insulation resistance test if >30V AC/DC present Operating Temperature: -20 to 55°C Rating: CATIV-600V Includes test leads, test probes, alligator clips, protective holster & batteries.

5kV MegOhmMeter • Resistance to 1TΩ • Ramp function • DAR & PI calculations • Auto-discharge • 99 memory storage 1550B • Live circuit voltage warning

L

L

•Insulation resistance to 10GΩ (1507) • Test voltages to 1000V 1507 • Calculates Polarization Index & Dielectric Absorption Ratio (1507) • AC/DC voltage measure to 600V • Pass/Fail function for repetitive tests (1507) • Remote probe for hard-to-reach tests


Megger® Insulation Resistance Testers MIT510 and MIT520 5kV Testers

NEW

This new generation of insulation testers offers increased measurement range, better accuracy, longer battery life, additional functionality and improved safety features.

MIT510/2

L

A rugged, portable tester designed for years of trouble free operation:

MJ15

MJ15 and BM15 The BM15 and MJ15 are compact 5-kV insulation testers that are simple to use and provide a quick, accurate reading of insulation resistance. Both instruments offer four test voltages (500 V, 1 kV, 2.5 kV, 5 kV), analog scales, and measurement sensitivity to 20 GΩ. Both units include “pass/fail” display overlays for a rapid “go/no go” testing and trend analysis. The BM15 is powered by 8 “AA” or rechargeable alkaline batteries while the MJ15 includes a hand-crank generator in addition to battery power.

• Dual operation from AC line or rechargeable batteries, so testing can continue even when recharging is overlooked • Resistance measurements to 15 TΩ, replacing ambiguous infinity readings with actual numbers than can be used for trending or predictive maintenance • Capacitance measurements from 1 nF to 50 µF, providing additional MIT510/2 equipment diagnostic information • Test lockout when an external voltage above 50V is present, for redundant safety • Simple operator controls and a 'quick start' guide in the lid, for efficient use of test time

L

MIT520/2 All the features of the MIT510 plus expanded capabilities to afford the skilled operator more flexibility in analyzing and reporting the condition of capital equipment: • Test voltage can be set in 10 V increments from 50 V to 1 kV, and in 25 V increments above 1 kV • Test results can be downloaded via RS232 or USB ports • Five industry standard tests can be programmed and run automatically • Step voltge (SV) • Insulation resistance (IR) • Dielectric absorption (DAR) • Dielectric discharge (DD) • Polarization index (PI)

MIT1020 10kV Insulation Tester

NEW

ORDERING INFORMATION

TEST EQUIPMENT

MIT1020/2 • Test voltage range from 50 V to 10 kV, in 10 V increments to 1 kV and 25 V increments above 1 kV • Increased measurment range to 35 TΩ, for testing the best insulating materials • Automatic performance of standardized tests, including Step Voltage, Dielectric Absorption Ratio and Dielectric Discharge • Capacitance measurements from 1 nF to 50 µF, providing additional equipment diagnostic information • RS232 or USB ports for downloading test results • A 'quick start' guide in the lid to make field operation simple and user-friendly

Catalog No. ME/MJ15 ME/BM15 ME/MIT510/2

ME/MIT520/2

L MIT1020/2

IEEE43:2000 "IEEE Recommended Practices for Testing Insulation Resistance of Rotating Machinery" now recommends testing machines rated above 12kV at 10kV. The Polarisation Index test is performed on equipment and cables to assess the general condition of the insulation before applying potentially destructive test voltages. The new MIT 5kV & 10kV models easily perform both these tests.

155

ME/MIT1020/2

Test Voltage (V dc) 500 1000 2500 5 kV 500 1000 2500 5 kV 500 1000 2500 5 kV 500 1000 2500 5 kV 10 kV

Resistance 100 kΩ – 20GΩ

10 kΩ – 15 TΩ

10 kΩ – 15 TΩ

10 kΩ – 35 TΩ


Megger® Insulation Resistance Testers MJ Series The MJ159 is the recognized industry standard, upgraded with modern circuitry. This analog meter allows the trained operator to determine much more from the needle movement than just a MΩ reading. Available in line, battery or hand cranked models. Other features include: IR measurements to 2000MΩ Four test voltages to 1kV Guard terminal Continuity and kΩ functions for troubleshooting

L

• • • •

MJ159

L

MIT400 Series

MIT410

The MIT400 Insulation/Continuity Testers offer outstanding performance and ease of use. Dual digital displays show test results and test voltage simultaneously. Hands free 200 & 20mA continuity test ranges ensure the accurate measurement of circuit conductors and bonding. An audible continuity alarm speeds testing. These models offer: Insulation resistance measurements to 200GΩ; selectable test voltages to 1000V Backlit LCD with dual digital and analog arc displays Leakage current readout (except MIT400) Live circuit warning & test inhibit for voltages >75V PI/DAR and Timer functions (except MIT400) IP54 & CAT IV 600V rating

L

• • • • • •

The MIT series offers TRMS & DC Voltage measurements to 600V. The MIT420 and MIT430 add capacitance (to 10uF), frequency (to 400Hz) and test result storage. MIT430 has Bluetooth for wireless data transfer and comes with Megger download software. All models include carrying case, test leads, battery. All models except the MIT400 also include a remote switch probe for “hands free” testing.

MIT310

MIT300 Series The new MIT300 Series features a large display and hands-free operation. The tough, rubber armored case is designed for rough handling and weatherproof to IP54. A rigid cover folds up to protect the front panel when not in use. Intelligent safety features include: • Safety Interlock – prevents unsafe connection of test leads • Safe contact detectors – the tester will remain safe and not be damaged if connected to a live circuit while on continuity setting. • Live voltage warning – alerts when circuit voltage is >25V. • Safety lockout – inhibits test when circuit voltage is >50V. • Continuity check – prevents a continuity test on a live circuit.

Each model includes a 200mA continuity test function and continuity buzzer. All models except the MIT300 measure DCV & ACV (50/60Hz) to 600V. The MIT330 adds memory for storing 1000 test results and a USB interface. The MIT310A has an analog meter display for those who prefer a moving needle.

ORDERING INFORMATION Model N o. MJ159 MJ559 MIT400

Tes t Volt age (V dc) 100, 250, 500, 1000 100, 250, 500, 1000 250, 500, 1000

ME/MIT410

MIT410

ME/MIT420

MIT420

ME/MIT430

MIT430

ME/MIT300 ME/MIT310 ME/MIT310A ME/MIT320 ME/MIT330

MIT300 MIT310 MIT310A MIT320 MIT330

50, 100 250, 500, 1000 50, 100 250, 500, 1000 50, 100 250, 500, 1000 250, 500 250, 500, 1000 250, 500, 1000

Insulation Resis tance 0 to 2000 MΩ 0 to 2000 MΩ 0.01 MΩ to 20 GΩ

Resis tance Range 0 to 5000 Ω 0 to 5000 Ω 0.01 Ω to 999 kΩ

0.01 MΩ to 100 GΩ

0.01 Ω to 999 kΩ

0.01 MΩ to 200 GΩ

0.01 Ω to 999 kΩ

0.01 MΩ to 200 GΩ

0.01 Ω to 999 kΩ

10 kΩ – 999 MΩ 10kΩ – 999 MΩ 10 kΩ – 999 MΩ with limit alarm

– – 10 Ω – 2 kΩ 0.01 – 99.9 Ω 10 Ω – 999 kΩ

Display Analog Analog Analog/ Dual Digital Analog/ Dual Digital Analog/ Dual Digital Analog/ Dual Digital Digital/Analog Digital/Analog Analog Digital/Analog w/backlight

Power Sour ce Hand-Cranked Line or Rech. Batt.

Alkaline or Rechargeable NIMH Battery (5 x AA)

Alkaline or Rechargeable NICD/NIMH Battery (8 x AA)

156

TEST EQUIPMENT

Cat alog N o. ME/212159 ME/212559 ME/MIT400


AEMC Megohmmeters 1000V Digital/Analog Megohmmeter Models 1050 & 1060 ®

• True Megohmmeter • Test voltage combinations of 50V, 100V, 250V, 500V and 1000V • Insulation measurements to 4000GΩ (4TΩ) • Direct measurement of DAR and PI values • Direct measurement of sample Capacitance • Display of test voltage and run time • Programmable test run times and PI times • Smooth and Alarm functions • Automatic test inhibition (if live sample >25V) • Automatic discharge after use with voltage display • Large dual display with time, voltage and measurement L 1060 • Bright blue electrolumenescent backlight • Battery powered (Model 1050) • Auto power-down when not in use • Remote operation with optional test probe • Rugged dual wall field case with detachable lead/accessory pouch • EN 61010-1, 600V Cat III, IEC 61557 and CE rated

5000V Digital/Analog Megohmmeter Models 5050, 5060 & 5070 • True Megohmmeter ® • Test voltage combinations of 500V, 1000V, 2500V and 5000V • Insulation measurements from 30kΩ to 10,000GΩ (10TΩ) • Selectable and programmable test voltage (40 to 5100V) • Automatic calculation of DAR, PI and DD ratios • Direct measurement and display of Capacitance and Leakage Current • Display resistance, test voltage and run time • Programmable test run times and PI ratio times • Smooth and Alarm functions L 5070 • Automatic test inhibition (if live sample >25V) • Automatic discharge and display of discharge voltage • Large dual display with time, voltage and measurements shown (Models 5050 and 5060) • Graphic and digital display of test voltage, resistance and more (Model 5070) • Bright blue electroluminescent backlight • Programmable test voltage lock-out DataView is included with the Models • Programmable alarm setting 1060, 5060 and 5070 • Auto power-down when not in use DataView® Software for Models 1060, 5060 & 5070 • AC or DC powered with rechargeable NiMH batteries • Configure all functions and run tests from your PC • Rugged, weatherproof field case • Retrieve and display data in real time • Designed and built to IEC safety standards • Retrieve data from memory in real time • Display plots & print reports • EN 61010-1, 1000V Cat. III ®

Model 1060 includes the following additional features: • AC rechargeable NiMH batteries • RS-232 interface for direct printing of results (serial output) • 128k memory to store measurements in specific files • Remote operation of megohmmeter through PC • Includes DataView ® software to configure instrument and generate reports

ORDERING INFORMATION AE/2130.01 AE/2130.03 AE/2130.20 AE/2130.21

AEMC Flexible Current Probe

L

TEST EQUIPMENT

AE/2130.30

Megohmmeter Model 1050 (Digital, with Analog Bargraph, Backlight, Alarm, Timer, 50V, 100V, 250V, 500V, 1000V, Auto DAR/PI, Res., Continuity) Megohmmeter Model 1060 (Digital, with Analog Bargraph, Alarm, Timer, 50V, 100V, 250V, 500V, 1000V, Auto DAR/PI, Res., Continuity, RS-232 with DataView® software, 128kB Memory) Megohmmeter Model 5050 (Digital, with Analog Bargraph, Backlight, Alarm, Timer, 500V, 1000V, 2500V, 5000V, Auto DAR/PI/DD) Megohmmeter Model 5060 (Digital, with Analog Bargraph, Backlight, Alarm, Timer, 500V, 1000V, 2500V, 5000V, Auto DAR/PI/DD, RS-232 w/DataView ® software) Megohmmeter Model 5070 (Graphical, Analog Bargraph, Backlight, Alarm, Timer, 500V, 1000V, 2500V, 5000V, Ramp, Auto DAR/PI/DD, RS-232 w/DataView ® software)

24-3001

• 24" flexible sensor fits around conductors up to 7.6" in diameter • Reads Amps directly on DMM or Scope • mV output directly proportional to AC current (10mV/A on 300A range and 1mV/A on 3000A range) • Accuracy 1% of Reading ± 500mA • 4% influence of conductor position in jaw • 300 hour battery life • EN 61010, 1000V Cat. III

ORDERING INFORMATION AE/2120.81 AE/2118.46

157

FlexProbe® Model 24-3001 (300/3000A, 24", 10mV/A/1mV/A, with lead) Banana (Female) – BNC (Male) Adapter (XM-BB) for use with scopes


AEMC Megohmmeters Digital/Analog Megohmmeter Models 1040 & 1045

500V Analog Megohmmeter Model 1005 1000V Analog Megohmmeter Model 1015

L

1040 & 1045

L

Ideal for acceptance testing and preventive maintenance

1015

For motors, cables, switchgear and general applications • • • • • • • • • • • •

True Megohmmeter ® Test voltage combinations of 250V, 500V and 1000V Insulation measurements to 2000MΩ (2GΩ) Automatic test inhibition (if live sample >25V) Automatic discharge for operator safety Multi-line 4000-count backlit digital display with analog bargraph Resistance measurements to 400kΩ Continuity with 200mA test current Timer function for easy DAR and PI (Model 1045) Over-molded slip-proof holster for rugged field use EN 61010-1, 300V Cat. II, EN 61557 and CE rated Supplied with a soft carrying case

Compact and lightweight Insulation measurements to 1000MΩ 600VAC test voltage range (safety check) 0 to 10Ω+ and 0 to 10Ω- continuity ranges Continuity measurements with 200mA test current Resistance range to 1000Ω (Model 1015) Push button for battery check Large, direct-reading, colored scale Rugged construction for heavy duty field use Supplied with test leads, shockproof rubber housing & soft carrying case

500V Hand-cranked Megohmmeter Model 1210N 1000V Hand-cranked Megohmmeter Model 1250N

1000V Megohmmeter • Test voltage combinations of 250V, 500V and 1000V • Insulation measurements to 4000MΩ • Resistance measurements to 4000Ω • Continuity test • Continuity beeper • 600VAC/DC test voltage range • Large, easy-to-read digital display • Data hold switch • Test button may be “locked-on” for three minutes for hands-free operation • Automatic discharge when test button is released • Low battery indicator • Supplied with a soft carrying case and test leads

• True Megohmmeter ® • Test voltages of 250V, 500V and 1000V • Insulation measurements to 200MΩ and 5000MΩ • LED indicates constant voltage output and proper cranked speed • Automatic discharge when measurement is finished • Auto-Ranging — dual scale operation for better sensitivity and easier readings • Designed for harsh environments: marine, mining, heavy-duty field, industrial and military use • Extra rugged cast aluminum case; O-ring sealed against rain, water and dust with aluminum lid • Compact self-contained package; folding vcrank • Large direct-reading scale

TEST EQUIPMENT

L 1026

• • • • • • • • • •

L 1250N

ORDERING INFORMATION AE/2116.92 AE/2116.93 AE/2117.30 AE/2117.31 AE/2117.72 AE/1326.01 AE/1326.02 AE/1402.01 AE/1403.01

Megohmmeter Model 1040 (Digital, with Analog Bargraph, Alarm, Backlight, 500V, 1000V, 400kΩ, Continuity) Megohmmeter Model 1045 (Digital, with Analog Bargraph, Alarm, Timer, Backlight, 250V, 500V, 1000V, 400kΩ, Continuity) Megohmmeter Field Kit, Model 1040 Megohmmeter Field Kit, Model 1045 Megohmmeter Model 1026 (Digital, 250V, 500V, 1000V, 4000Ω, V) Megohmmeter Model 1210N (Hand-cranked, 500V, 500kΩ, Continuity) Megohmmeter Model 1250N (Hand-cranked, 250V, 500V, 1000V) Megohmmeter Model 1005 (Analog, 500V, Continuity) Megohmmeter Model 1015 (Analog, 500/1000V, Resistance, Continuity)

158


AEMC Ground Resistance Testers Digital Ground Resistance Tester Models 4620 & 4630 • Measures soil resistivity (4-Point) method • Measures ground resistance (2- and 3-Point) Fall-of-Potential method • Step voltage tests and touch potential measurements • Auto-Ranging: automatically selects the optimum range • Designed to reject high levels of noise and interference • Extremely simple to operate: connect – press – read • LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections • Large easy-to-read backlit display • Battery powered (Model 4620) • AC powered with rechargeable NiMH batteries (Model 4630) • Rugged dustproof and rainproof field case • Can also be used for continuity tests on bonding • Color-coded terminals

Clamp-On Ground Resistance Tester Models 3711 & 3731

L 3731

US Patent No. 362,639

L 4630

• Simple and fast clamp-on operation — no leads, no auxiliary rods or spacing requirements • Direct reading of ground resistance from 0.1Ω to 1200Ω • Direct reading of continuity and ground loop resistance • Direct reading of ground leakage or phase current from 1mA to 30Arms • Jaw design with large 1.25" (32mm) window — accommodates up to 1000MCM cables • Auto-Off for power management • Alarm function with adjustable set point and buzzer for quick field checks (Model 3731) • Memory function to store 99 field measurements for later retrieval and analysis (Model 3731) • Meets EN 61010-1, Cat. III and CE Mark • Rugged Lexan® head and body construction resists breakage • Alarm settings and stored memory information saved during shutdown (Model 3731) • Patented design

Also available as full kits

NEW • 2- and 4-Wire Bond Resistance/Continuity measurement • 3-Point Fall-of-Potential measurement with manual/automatic frequency selection • 4-Point soil resistivity measurement with automatic calculation of Rho & user selection of Wenner or Schlumberger method • 3-Point earth coupling measurement • Frequency scan 40-513Hz for testing in electrically noisy environments • Selectable test voltage of 16 or 32V up to 250mA of test current • Automatic recognition of all electrode connections & resistance • Stores up to 512 complete test results • Optically isolated USB communication • Rechargeable NiMH batteries from wall charger or vehicle power • Rugged dustproof and rainproof field case • Includes DataView® software for remote operation, data storage, real-time display, analysis, report generation & system configuration Model 6742 adds: • Manual and automatic frequency scan to 5078Hz • Measures Ground Resistance using the 2 clamp method (selective ground testing) • Measures Ground Impedance up to 5kHz to test lightning strike protection

Tester includes meter, NiMH batteries, optical USB cable, DataView® software, external battery charger, power cord, user manual. Kit includes Tester, test leads, 30 ft ground lead (green), auxiliary ground electrodes, spaded lugs, 100 ft tape measure, ground tester workbook CD, carrying bag for meter, carrying bag for kit.

L

TEST EQUIPMENT

Multi-Function Ground Resistance Tester Models 6470B & 6472

6470B

ORDERING INFORMATION AE/2130.43 AE/2130.44 AE/2130.45 AE/2130.46 AE/2117.60 AE/2117.61 AE/2135.01

Ground Resistance Tester Model 4620 (4-Point, Digital, Battery Powered) Ground Resistance Tester Model 4630 (4-Point, Digital, Rechargeable Battery) Ground Resistance Tester Model 4620 Kit Ground Resistance Tester Model 4630 Kit Ground Resistance Tester Model 3711 (Clamp-On) Ground Resistance Tester Model 3731 (Clamp-On with memory and alarm) Ground Resistance Tester Model 6470B

*2 probes required for two clamp testing method.

159

AE/2135.02 Ground Resistance Tester Model 6470B 3-point Kit – 150 ft leads AE/2135.04 Ground Resistance Tester Model 6470B 4-point Kit – 500/100 ft leads AE/2135.51 Ground Resistance Tester Model 6472 AE/2135.52 Ground Resistance Tester Model 6472 3-point Kit – 150 ft leads AE/2135.54 Ground Resistance Tester Model 6472 4-point Kit – 500/100 ft leads AE/2135.71* AC Current Probe Model MN82 for use with Model 6472 AE/2135.72* AC Current Probe Model SR182 for use with Model 6472


Megger® Ground Resistance Testers Three-Terminal Ground Resistance Testers

Four-Terminal Ground Resistance Testers

®

BIDDLE Model 250260 is the tried and proven analog tester. It is a simple, three-terminal model that will tolerate 2V peakto-peak voltage interference.

Addition of a fourth terminal permits soil resistivity testing as well as more precise resistance (installed ground) measurements. The new DET4TD2 offers the same features as the DET3TD, but with 4-terminal capability and a 20kΩ upper resistance limit. The DET4TC2 increases this to 200kΩ. The DET4TCR2 has rechargeable batteries that can be charged from the AC mains or a vehicle battery (with optional adapter). The DET4TC2 and DET4TCR2 offer 4 test frequencies for testing in noisy environments. Both models can be ordered with clamps to perform the stakeless test method, like a clamp style earth tester. A backlit LCD provides improved visibility in dark locations.

The MEGGER® DET3TD is a digital tester with an expanded resistance range and selectable 25/50V test voltage. It rejects noise up to 40V p-p and measures earth voltages up to 100V. The DET3TC adds an ART (Attached Rod Technique) resistance measurement and earth current measurements from 0.5mA to 19.9A with the optional current clamp.

For testing in extreme electrical environments, the DET2/2 offers full autoranging, 0.001Ω resolution, adjustable test frequency and additional interference filtering.

250260

L

DET4TCR2+Clamps

L

L

All DET3 and DET4 models are CAT IV 100V and IP54 rated. Test leads and carrying case are included.

DET2/2

DET3TC

DET4TCR2

L

L

NEW

ORDERING INFORMATION Measur ement

Resis tance

250260

2/3 Term.

DET2/2

Volt age

Gnd Cur rent

Power Sour ce

Display

Tes t Leads

0.5 - 500Ω

Battery

Analog

250560

2/3/4 Term.

0.010Ω - 20kΩ

Rechargeable Battery

Digital

250581

DET3TD

2/3 Term.

0.01 - 2000Ω

0 - 100V

Battery

Digital

included

DET3TC

2/3 Term. + ART*

0.01 - 2000Ω

0 - 100V

Battery

Digital

included

0.5mA - 19.9A*

DET4TD2

2/3/4 Term.

0.01Ω - 20kΩ

0 - 100V

Battery

Digital

included

DET4TC2

2/3/4 Term.

0.01Ω - 200kΩ

0 - 100V

Battery

Digital

included

2/3/4 Term. + stakeless

0.01Ω - 200kΩ

0 - 100V

0.5mA - 19.9A

Battery

Digital

included

DET4TCR2

2/3/4 Term.

0.01Ω - 200kΩ

0 - 100V

Digital

included

DET4TCR2 +Clamps

2/3/4 Term. + stakeless

0.01Ω - 200kΩ

0 - 100V

0.5mA - 19.9A

Rechargeable Battery

DET4TC2+Clamps

* Attached Rod Technique (ART) requires optional current measuring clamp.

160

TEST EQUIPMENT

Model N o.


Megger® Clamp-on Testers

Hioki Battery Testers

L

Ground Resistance Testers • Easy, fast clamp-on operation – No rods or cables necessary • Measures ground resistance from 0.025Ω to 1500Ω • Measures ground leakage or phase current from 0.2mA to 35A • Auto ranging with high and low alarms • Automatic self calibration DET20C

APPLICATIONS

• Measure resistance and continuity of grounding loops around pads and buildings. • Check multi-grounded systems without disconnecting the ground rod/stake under test. • Measure leakage current flowing to ground or circulating in ground systems. • Use on cell towers, RF transmitters and telecommunications sites. • Inspect and verify lightning protection systems. • Test consumer installations, including pools, spas, etc.

TEST EQUIPMENT

FEATURES

• Large LCD display screen can be read in bright sunlight. • Large 1.36" (35mm) jaw opening to accommodate a variety of conductors. • Indication of high noise content that may affect readings. • Hold function for difficult to reach installations. • Auto-off to save on battery power. • Configurable high and low alarms with audible indication for fast field checks. • On board storage of test results (up to 8180 records). • Calibration check loop to insure proper operation. • Rugged construction for regular field use. • Lightweight storage case contains complete testing kit. Model DET20C includes RS-232 interface and software for downloading test data. Both models include battery, carrying case & calibration loop. ORDERING INFORMATION ME/DET10C ME/DET20C

161

Digital Earth Test Clampmeter Digital Earth Test Clampmeter with RS-232 Interface

L

NEW 3554

• Test without disconnecting the batteries • Three level indication: Pass, Warning, Fail • Audible beeper (3555) • PC Interface & software (3554) Get an instantaneous check of battery condition based on internal resistance and voltage. Model 3554 for medium and high capacity lead-acid batteries. Model 3555 for compact storage batteries used in portable telephones and similar applications. SPECIFICATIONS 3554 Measurement Ranges: Ohms: # Ranges Best resolution Accuracy Test Current DC Volts Best resolution Accuracy Temperature Resolution Test Frequency Max. Input Comparator # Limit Sets Data Memory Alert Batteries Life PC Interface Operating Temp. Dimensions

3555

3µΩ-3Ω 300µΩ-30Ω 4 3 1µΩ 100µΩ 0.8% rdg +6d 0.8% rdg +6d 150mA-1.5mA 5mA-50µA ±6V, ±60V ±3V, ±30V 1mV 1mV 0.08% rdg +6d 0.1% rdg +6d -10 to +60°C -0.1°C -1kHz 1kHz 60V DC 50V DC Hi & low ohm limit, low volt limit (both models) 200 stored 10 stored 4800 data/limit sets -LCD icon LED & Beeper 9 x AA 6 x AA up to 10 hrs up to 18 hrs USB -0-40°C, <80% RH non-condensing 7.7 x 5.1 x 2.2" (196x130x55mm)

SUPPLIED ACCESSORIES 3554 3555

Pin-type test leads, USB cable, data management software, carrying case, zero adjust board, batteries, spare fuse Pin-type test leads, batteries.

ORDERING INFORMATION HK/3554 HK/3555 HK/9382 HK/9453 HK/9466

Battery Tester (lead-acid batteries) Battery Tester (portable batteries) Carry case for 3555 4-terminal lead set Remote Control Switch for 3554


Megger® High-Pot Testers Production Line High-Pot Testers 230415

L

BIDDLE® High-Pot Testers are designed for ease of operation and readily adapt to development, maintenance or production testing. These instruments are supplied with 4-ft removable probes. Available in one AC/DC and two AC models; the AC units feature a front-panel, NEMA-5-15R three-prong output receptacle. The BIDDLE high-pot testers are packed with features for safety and convenience, including: Ground continuity check of 3-wire devices with high voltage interlock Visual and audible alarms Leakage current adjustable on front-panel from 0.3 to 12.3 mA One-second or continuous testing Automatic failure shutdown Recessed high-voltage connections

Catalog No.

Model

ME/230315 ME/230415 ME/230425

AC AC AC/DC

Applied Test Voltage 0–3 kV ac 0–4 kV ac 0–4 kV ac 0–5 kV dc

Adjustable Leakage Current Trip Level 0.3 to 12 mA 0.3 to 12 mA AC: 0.3 to 12 mA DC: 0.43 to 17 mA

Megger® Digital Low Resistance Ohmmeters

Range 1.9999 mΩ 19.999 mΩ 199.99 mΩ 1999.9 mΩ 19.999 Ω 199.99 Ω 1999.9 Ω

Resolution 0.1µΩ 1 µΩ 10 µΩ 100 µΩ 1 mΩ 10 mΩ 100 mΩ

Current 10 A 1A 100 mA 10 mA 1 mA 0.1 mA 0.1 mA

Test Leads & Battery Charger Included

Resolution 10 mΩ 100 mΩ 0.1µΩ 1 µΩ 10 µΩ 100 µΩ 1 mΩ 10 mΩ 100 mΩ

DLRO10HD

Current 10 A 1A 10A 1A 100 mA 10 mA 1 mA 0.1 mA 0.1 mA

DLRO with LED display DLRO with LCD display Heavy Duty DLRO (LCD display)

DLRO 200 • Test currents from 10A to 200A DC • Filtered DC output eliminates magnetic transients • 0.1µΩ best resolution • Full QWERTY keyboard • On board memory for up to 300 test results and notes • RS232 port to download stored results or for real time output to a printer

Measurement Range: 0.1µΩ to 999.9mΩ Test Modes: Normal, Continuous, Auto. Use continuous mode for long duration tests, Auto mode for rapid sequential testing. Test Time: 10 seconds Display: Large backlit LCD Dimensions: 16.4" x 9.9" x 10.7" (410x250x270mm) Weight: 32 lbs (14.5kg) Power: 100-130VAC, 50/60Hz

TEST EQUIPMENT

ME/DLRO-10 ME/DLRO-10X ME/DLRO10HD

Range 250.00 mΩ 2500.0 mΩ 2500.0 µΩ 25.000 mΩ 250.00 mΩ 2500.0 mΩ 25.000 Ω 250.00 Ω 2500.0 Ω

NEW L

DLRO–10 DLRO10HD • Accurate results in under three seconds • Delivers up to 10A into 250mΩ (25W) • Auto current reversal cancels standing emfs • Operates from rechargeable battery or line power • Fuse protected to 600 V • Input protected to 600V • NiMH battery reduces weight • Heavy duty IP65 case • 250 mW power limit avoids heating the test sample • 5 test modes, including auto-start on connection • Autoranging with high/low limits (DLRO 10X) • Simple to use rotary switches

L

• • • • • •

DLRO 200

Supplied with 16 ft. (5m) test leads and download software. A variety of C-clamp, Kelvin clips, fixed point and spring point leads are available in various lengths. ME/DLRO200-115E

High Current Digital Low Resistance Ohmmeter

162


Altek Process Calibrators Milliamp Calibrator

MILLIAMP CALIBRATOR SPECIFICATIONS Ranges Accuracy Burden Drive Battery Life

L

• Source and Read 0-24mA • Simulate 2-wire Transmitters • Quik-Chek Pushbuttons

134-2

Use the PocketCal 134-2 to simultaneously power and measure two-wire transmitters up to 12V. Simulate the transmitter in circuits from 3 to 45V.

LOOP CALIBRATOR SPECIFICATIONS Source/Simulate Read Accuracy

Loop Calibrator • Source to 24mA, Read to 52mA • Measure to ±99.9V DC • Quickly Simulate 2-wire Transmitters The versatile 334A will check, calibrate and troubleshoot all the signals in a 4-20mA process control loop. Simultaneously power and measure two-wire transmitters up to 27V. Simulate the transmitter in circuits from 3 to 45V. Overload protected to 135VAC.

0.00 to 24.00mA, -25.0 to 125.0% of 4 to 20mA 0.03mA 0.9V @4mA, 1.9V @24mA 700Ω@20mA with fresh batteries 40hr simulate, 20hr source from 9V batteries (supplied)

Drive Battery Life

0.00 to 24.00mA, -25.0 to 125.0% of 4 to 20mA 0.00 to 52.00mA, -25.0 to 300.0% of 4 to 20mA 0-24mA: ±0.05% of reading ± 1 digit Quik-Chek: ±0.03% of reading ± 0.01mA 1200Ω@20mA with fresh batteries 100hr simulate, 20hr source from 9V batteries (supplied)

VOLTAGE CALIBRATOR SPECIFICATIONS

334A

L

Range Accuracy Source/Sink Battery Life

0 to 199.9mV, 0 to 19.99V, -25.0 to 199.9% of 1 to 5V ±0.05% of span ± 1 digit 30mA/20mA max Approx. 100 hrs from 9V alkaline battery (supplied)

Voltage Calibrator

TEST EQUIPMENT

• Source and Read to 19.99V • Simulate 2-wire Transmitters • Easy Dial Setting Easily check DC voltage instrumentation, even live circuits, with the Model 235. Use the ‘Quik-Chek’ switch for rapid zero and span verification. Overload protected to 120V AC or DC.

Multifunction Calibrator • Calibrate Milliamps, Volts & Frequency • Check Thermocouple & RTD Sensors • Use in Place of a DMM for ACV & Ohms • Simulate 2-Wire Transmitters

MULTIFUNCTION CALIBRATOR SPECIFICATIONS FUNCTION mA Source/Measure mV V V (measure only) VAC (measure only) TC RTD Ohms Frequency Simulate Range ma Compliance Transmitter Drive Battery Life

The deluxe Model 820E combines the functions of the 111, 322-1, 334A and 235 calibrators in one compact unit. It also performs frequency calibration and extended voltage measurements.

163

RANGE 0.00 to 24.00mA, -18.8 to 125.0% of 4 to 20mA 0.00 to 110.00mV DC (20mA max source/sink) 0.00 to 10.25V DC (20mA max source/sink) 0.0 to 200.0V DC 0.0 to 250.0V AC TRMS J, K, T, E 100Ω Pt, 385 alpha (2mA max) 0 to 400.0Ω source, 0 to 1000.0Ω measure 1-1000 CPM, 1-1000 Hz, 0.01-10.00 kHz 3 to 45V 25V (max 1.9V burden at 24mA) 1200Ω@20mA typical, Power & Measure mode 50hr simulate, 20hr source (AA batteries supplied)

ACCURACY ±0.05% of FS ± 1d ±0.05% of FS ± 1d ±0.05% of FS ± 1d ±2% of FS ± 1d ±2% of FS ± 1d ±2% typical ±1°C ±0.06Ω ±0.05% of FS ± 1d

ORDERING INFORMATION (Batteries & three year warranty included) AL/334A Milliamp Loop Calibrator with Carrying Case AL/134-2 PocketCal Milliamp Calibrator AL/235 Voltage Calibrator AL/820E TechChek Multifunction Calibrator with Carrying Case AL/3331E Carrying Case with Belt Clip for 134-2 AL/3330T Carrying Case with Belt Clip for 235


Altek Temperature Calibrators RTD Calibrators • Source and Read Pt RTDs • 8 RTD Types Plus Ohms (Model 211) • 0.1° and 0.01Ω Resolution • °C/°F Display • Easy Dial Setting • Small and Lightweight

L

111

The Model 111 simulates and measures 3-wire, 100Ω Platinum RTDs over the full industrial temperature range. The Model 211 handles multiple RTD types in either 3 or 4 wire configurations, plus extended ohms range.

SPECIFICATIONS MODEL 111 RTD Type Accuracy

100Ω Pt (DIN/IEC/JIS), 385 alpha -200.0 to 200.0°C (-328.0 to 212.0°F) ±0.5°C (±0.9°F) 200.0 to 700.0°C (212.0 to 750.0°F) ±0.6°C (±1.0°F) 700.0 to 850.0°C (750.0 to 1562.0°F) ±0.7°C (±1.2°F)

MODEL 211 RTD Type Pt100 (DIN/IEC/JIS) Pt100 (JIS 1981) Pt100 (Burns) Pt100 (US lab) Pt1000 (HVAC) Cu10 (Minco) Ni120 Ni110 Accuracy (typical)

MODEL 111 & 211 Ohms Excitation Current Temperature Drift Battery Life Size

Thermocouple Calibrators • Source and Read Modes • 0.1° and 0.001mV Resolution • °C/°F Display • Easy Dial Setting • Small and Lightweight

Simulate and measure the most popular thermocouple types with the Model 322-1. Use the Model 422 with 14 different types. Three output memories for each TC type facilitate repetitive testing. Each model accepts miniature thermocouple connectors and direct thermocouple wires.

Range -200.0 to 850.0°C (-328.0 to 1562.0°F) -200.0 to 648.9°C (-328.0 to 1200.0°F) -195.6 to 648.9°C (-320.0 to 1200.0°F) -200.0 to 862.0°C (-328.0 to 1584.0°F) -184 to 275°C (-300 to 527°F) -200 to 260°C (-328 to 500°F) -80.0 to 273.0°C (-112.0 to 524.0°F) -106.7 to 315.6°C (-160.0 to 600.0°F) ±0.15°C (±0.25°F) ±0.10°C (±0.2°F) ±1.1°C (±2.0°F)

0.00 to 410.00 ±0.2Ω accuracy 0.0 to 2010.0 ±0.5Ω accuracy (211 only) 0.09 to 5.80 mA source, 1mA read <0.01%/°C change in ambient Approx. 50 hrs from 9V alkaline battery (supplied) 5.2" x 2.6" x 2.5" (130x67x64 mm)

SPECIFICATIONS Input/Output (322-1) Input/Output (422) Ranges

Accuracy Cold Junction Effect Battery Life Size

Type J, K, T, E and mV Type J, K, T, E, R, S, B, N, G, C, P, L, U, D and mV J: -210.0 to 1200.0°C (-346.0 to 2192.0°F) K: -230.0 to 1371.1°C (-382.0 to 2500.0°F) T: -260.0 to 400.0°C (-436.0 to 752.0°F) E: -240.0 to 1000.0°C (-400.0 to 1832.0°F) R, S: -18.3 to 1767.8°C (-1.0 to 3214.0°F) B: 315.6 to 1820.0°C (600.0 to 3308.0°F) N: -230.0 to 1300.0°C (-382.0 to 2372.0°F) G: 100.0 to 2320.0°C (212.0 to 4208.0°F) C, D: -1.1 to 2320.0°C (30.0 to 4208.0°F) P: -217.8 to 1395.0°C (-360.0 to 2543.0°F) mV: ±99.999mV ±(0.008% + 0.006mV), typically ±0.2°C or better <0.05°/°C change in ambient Approx. 40 hrs from 9V alkaline battery (supplied) 5.2" x 2.6" x 2.5" (130x67x64 mm)

ORDERING INFORMATION (Batteries, carrying case and three year warranty included) AL/111 RTD Calibrator (100Ω Pt, 385) AL/211 RTD Calibrator (8 types) AL/322-1 Thermocouple Calibrator (type J, K, T, E) AL/422 Thermocouple Calibrator (14 types)

164

TEST EQUIPMENT

L

322-1

Alpha 3850 3916 3902 3926 3750 4274 6720 5801 Pt100 Pt1000, Ni Cu10


Yokogawa Calibrators CA11E Voltage/Current Calibrator

CA12E Temperature Calibrator

• Source and Measure Voltage and Current • 4-20mA and 1-5V DC Step-up/down Function • 20mA SINK Function • Sweep Function • 0.05% Basic Accuracy

• • • •

Simulate Thermocouples and RTDs Multi-range RTD Thermometer °C/°F Selection Built-in Sensor for Reference Junction Compensation • 0.05% Basic Accuracy • Binding Post Terminal Adapter

SPECIFICATIONS

SPECIFICATIONS Sour c e / M e a s u r e m e n t F u n c t i o n s

Sour c e / M e a s u r e F u n c t i o n s R ang e 30V 10V 1-5V (source only) 1V 100mV 20mA 4-20mA (source only) 20mA SINK (source only)

Selection Type K Type E Type J Type T Type N Type R, Type S Type B Type L Type U RTD Pt100 (3 wire) 100mV 400Ω

Span 0 to 30.00V DC 0 to 11.000V DC 1/2/3/4/5V DC 0 to 1.1000V DC 0 to 110.00mV DC 0 to 24.000mA DC 4/8/12/16/20mA 0.1 to 24.000mA

CA71/SP1 Multi-function Calibrator • Simultaneous Source & Measure Capability • Separate Source & Measure Switches for Easy Setup • Autostep, Sweep & Memory Functions • 0.025% Measure Accuracy (DCV) Each CA71/SP1 includes: 120VAC adapter, source & measure cables, terminal adaptor for temperature measurements, input fuse, magnetic instrument case, accessory case for input cables, carrying case, 9 pin RS232 communications cable & data logging software.

TEST EQUIPMENT

SPECIFICATIONS S O U R CE FUN C T I O N S DCV DCA mA sink Resistance RTD TC TC Frequency Pulse MEASURE FUN C T I O N S DCV DCA Resistance ACV RTD TC TC Frequency Pulse

165

RAN GES 100mV/1V/10V/30V 20mA/4-20mA 20mA 400Ω Pt100 (-200 to +850°C) JKTELUN RSB 500/1000/10kHz 99999 cycles RAN GES 100mV/1V/10V/100V 20mA/4-20mA 400Ω 1/10/100/300V Pt100 (-200 to +850°C) JKTELUN RSB 100/1000/10kHz 99999 counts/min, /hr

BES T RESOL UTION 10mV 1µA 1µA 0.01Ω 0.1°C 0.1°C 1°C 0.2Hz 1 BES T RESOL UTION 10mV 1mA 0.01Ω 1mV 0.1°C 0.1°C 1°C 0.01Hz 1

BES T ACCURA CY 0.02%+15µV 0.025%+3µA 0.05%+3µA 0.02%+0.1Ω 0.025%+0.3°C 0.02%+0.5°C 0.02%+1.5°C 0.2Hz -BES T ACCURA CY 0.025%+20µV 0.025%+4µA 0.05%+0.1Ω 0.5%+5 digits 0.05%+0.6°C 0.05%+1.5°C 0.05%+2°C 2 digits --

Sour c e / M e a s u r e -200.0 to 1372.0°C -328 to 2498°F -200.0 to 1000.0°C -328 to 1832°F -200.0 to 1200.0°C -328 to 2192°F -200.0 to 400.0° C -328 to 752°F -200.0 to 1300.0°C -328 to 2372°F 0 to 1768°C 32 to 3214°F 600 to 1800°C 1112 to 3272°F -200 to 900°C -328 to 1652°F -200 to 400°C -328 to 752°F -200.0 to 850.0°C -328 to 1562°F -10.00 to 110.00mV 0 to 400.0Ω

CA150/SP1 Multi-function Calibrator • Simultaneous Source & Measure Capability • Large LCD Display • Step, Linear & Programmed Sweeps • Loop Power Supply • DC Voltage and Current Generation • Settings and Data Memory • 0.02% Measure Accuracy (DCV) Each CA150/SP1 includes: 120VAC adapter, source & measure cables, terminal adaptor for temperature measurements, input fuse, NiMH battery, accessory case for input cables & carrying case

SPECIFICATIONS S O U R CE FUN C T I O N S DCV DCA mA sink Resistance RTD TC TC Frequency Pulse MEASURE FUN C T I O N S DCV DCA Resistance RTD TC TC Frequency Pulse

RAN GES 100mV/1V/10V/30V 20mA 20mA 500/5k/50kΩ Pt100 (-200 to +850°C) JKTELUN RSB 100/1000/10k/50kHz 1100 CPM RAN GES 500mV/5V/35V 20mA/100mA 500/5k/50kΩ Pt100 (-200 to +850°C) JKTELUN RSB 100/1000/10kHz 100000 CPM, CPH

BES T RESOL UTION 1µV 1µA 1µA 0.01Ω 0.1°C 0.1°C 1°C 0.01Hz 0.1 CPM BES T RESOL UTION 10µV 1µA 0.01Ω 0.1°C 0.1°C 1°C 0.01Hz 1

BES T ACCURA CY 0.02%+10µV 0.02%+3µA 0.025%+6µA 0.02%+1.5Ω 0.025%+0.3°C 0.02%+0.4°C 0.02%+1.2°C 0.05Hz 0.5 CPM BES T ACCURA CY 0.02%+50µV 0.025%+4µA 0.055%+0.075Ω 0.05%+0.6°C 0.05%+1.5°C 0.05%+2°C 2 digits --


Martel Beta Process Calibrators Universal Temperature

L

Multi-Function

MC–1200

• Calibrate thermocouples and RTDs with one unit • Works with smart (pulsed) transmitters • Direct keyboard entry or scroll control • 9 user-defined setpoints for each type • Rugged NEMA 4X case • High accuracy ±0.4°C J T/C, ±0.3°C 4w RTD PTC–8001 • Auto step function

L

• Measure and source T/Cs, RTDs, Ohms, current, voltage, frequency; source pulse trains • Isolated mA/V read-back for complete transmitter calibration • Pressure module communication port • Built-in 24 V supply drives 4–20mA loops • Direct entry of custom RTD coefficients • All source modes can be programmed with setpoints to speed linearity tests • Highest accuracy in class (to 0.015% rdg.)

SPECIFICATIONS

SPECIFICATIONS

Read and Source Voltage Current (mA) Source 0.000 to 20.000 VDC 0.000 to 24.000 mA Read Isolated 0.000 to 30.000 VDC 0.000 to 24.000 mA Read Non-isolated 0.000 to 20.000 VDC 0.000 to 24.000 mA Accuracy ±0.015% of rdg ±2 µV ±0.015% of rdg ±2 µA Thermocouple mV Frequency (1-20 V amplitude) Read & Source -10.000 to +75.000 mV CPM Source & Read 2.0 to 600.0 CPM Accuracy ±0.02% of rdg, ±10 µV Hz Source & Read 1.0 to 1000.0 Hz kHz Source & Read 1.0 to 10.00 kHz Ohms Pulse Source (1-20 V amplitude) Source 5.0 to 4000Ω Read 0.00 to 4000.0Ω Pulses 1 to 30,000.0 Rate 2 CPM to 10 kHz Read and Source Range (Accuracy) °C Read and Source Range (Accuracy) °C Ni120 (672) -80.0 to +260.0 (0.2) -200.0 to +800.0 (0.2) J -200.0 to +1200.0 (0.2) Pt100 (385) Pt100 (3926) -200.0 to +630.0 (0.2) K -200.0 to +1370.0 (0.3) Pt100 (3916) -200.0 to +630.0 (0.2) T -200.0 to +400.0 (0.2) Pt200 (385) -200.0 to +630.0 (0.8) E -200.0 to +950.0 (0.2) Pt500 (385) -200.0 to +630.0 (0.4) R -20.0 to +1750.0 (1.2) Pt1000 (385) -200.0 to +630.0 (0.2) S -20.0 to +1750.0 (1.2) -100.0 to +260.0 (1.4) B +600.0 to +1800.0 (1.2) Cu10 YSI400 +15.00 to +50.00 (0.1) C 0 to +2316.0 (0.6) Cu50 -180 to +200 (0.4) XK -200.0 to +800.0 (0.2) Cu100 -180 to +200 (0.3) BP 0 to +2500.0 (0.9) Pt385-10 -200 to +800.0 (1.4) L -200.0 to +900.0 (0.2) -200 to +800.0 (0.4) U -200.0 to +400.0 (0.25) Pt385-50 N -200.0 to +1300.0 (0.4) Operating Temperature: Stability: Dimensions

-10 °C to +50 °C ±0.005% of reading/ °C outside 18-28 °C 8.7" x 4.2" x 2.3"

Loop Calibrator

L

SPECIFICATIONS Current Source & Measure Range: 0.000 to 24.000 mA, -25 to +125 % Voltage (Reading): 0 to 28 VDC Input Protection: Fuseless, up to 250 VAC Drive Capability: 1200Ω without Hart, 950Ω with Hart Loop Supply: 24 VDC Range Select: Decade Incremental to 0.001 mA steps Resolution: 1 µA Accuracy: ±0.015% of reading ± 2 µA Operating Temp.: -10 to +55 °C Dimensions: 5.7" x 3.15" x 1.43"

Connectors: Operating Temp.: Dimensions:

NI120 (672) Pt 100 (385) Pt 100 (3926) Pt 100 (3916) Pt 200 (385) Pt 500 (385) Pt 1000 (385) Cu10 YSI400 Ohms

-80.0 to 260.0 -200.0 to 800.0 -200.0 to 630.0 -200.0 to 630.0 -200.0 to 630.0 -200.0 to 630.0 -200.0 to 680.0 -100.0 to 250.0 15.0 to 50.0 0.0 to 400.0, 400 to 3200 plus Pt 392, JIS, Ni120

Standard mini-plug for T/C, banana jack for RTDs -10 to +50 °C 8.7" H x 4.2" W x 2.3" D

ORDERING INFORMATION MA/MC-1200

Multi-Function Calibrator with test leads, 4 AA batteries, NIST certificate MA/PTC8001 Universal Temperature Calibrator with test leads, 4 AA batteries, NIST certificate MA/IVC-222 HP11 Voltage/Current Calibrator with test leads, carrying case, 9V battery, NIST certificate MA/TC-100 Thermocouple Calibrator with 9V battery, NIST certificate MA/LC-100 Loop Calibrator with test leads, 9V battery, NIST certificate MA/CC572 Carrying Case for PTC8001, MC-1200 A variety of temperature probes are available.

Thermocouple Calibrator

Voltage/Current Calibrator

• 10 T/C types plus mV • ±0.3°C accuracy (type J) • Accepts T/C mini-plug & bare T/C wires • 3 setpoints for each T/C type • MIN/MAX recall in measure mode • Input protection to 240 VAC

• 0.015% of reading accuracy • 200 mV, 2 V, 20 V and 24 mA ranges • 24 V supply can drive 4-20 mA loops • 2 stored setpoint values • Intuitive, easy-to-use controls IVC-222HPII

TC-100

L

SPECIFICATIONS Voltage Source & Measure Range: Resolution: Accuracy: Output Impedance: Input Impedance:

-10 to +75.000 mV 1 µV ±0.007% of reading, ±10 µV ≤1 Ω >1 MΩ

Thermocouple Source/Measure Types: J, K, T, E, R, S, B, L, U, C Resolution: 0.1°C or °F source 0.01°C or °F measure Operating Temp: -10 °C to +55 °C Dimensions: 5.7" x 3.15" x 1.43"

TEST EQUIPMENT

• Simulates, powers & measures two-wire transmitters • Five preset outputs (4, 8, 12, 16, 20 mA) • 0.001 mA resolution • Adjustment level knob • % Error function eliminates manual calculation • Measures loop power & Hart devices LC-100

Read & Source Range J -200.0 to 1200.0 K -200.0 to 1370.0 T -200.0 to 400.0 E -200.0 to 950.0 R -20.0 to 1750.0 S -20.0 to 1750.0 B 600.0 to1800.0 L -200.0 to 900.0 U -200.0 to 400.0 N -200.0 to 1300.0 mV -10.0 to 75.00

L

SPECIFICATIONS Resolution Voltage: Current: Accuracy: Temp. Stability: Load Capability Voltage: Current: Output Protection: Operating Temp: Dimensions:

0.01 mV, 0.0001 V, 0.001V 0.001 mA ±0.015% of reading, ±2 count; 18 °C to 28 °C ±0.005% FS/°C ±1 mA for rated accuracy 1kΩ Current limited internal RESET -10 °C to +55 °C 1.43" x 3.15" x 5.7"

166


Fluke Process Loop Calibrators Fluke 707 Loop Calibrator 705 Features, Plus: • Output Adjustment Dial • HART™ Mode • 0.015% Accuracy

SPECIFICATIONS Functions Voltage measurement Range Resolution Accuracy

Fluke 705 and 707

Current measurement Range Resolution Accuracy Current sourcing Range Accuracy Drive capability Loop power while measuring mA Voltage sourcing Resistance measurement Frequency Diode test Continuity Display current and % of span Auto step, auto ramp Span Check

Fluke 715

Fluke 787 and 789

0-28 V dc 0-100 mV 0-10 V 0.001V 10 µV 1 mV 705: 0.025% Rdg + 1 LSD 0.02% Rdg + 2 LSD 707: 0.015% Rdg + 2 LSD

0-1000 V ac or dc 0.1mV to 1.0V 0.1% Rgd + 1 LSD (VDC)

0-24 mA 0.001 mA 705: 0.02% Rdg + 2 LSD 707: 0.015% Rdg + 2 LSD

0-24 mA 0.001 mA 0.015% + 2 LSD

0-1A dc 1mA dc 0.2%+2 LSD

0-20 mA or 4-20 mA1 705: 0.025% Rdg + 2 LSD 707: 0.015% Rdg + 2 LSD 705: 1000Ω @ 24 mA 707: 1200Ω @ 24 mA 24V

0-20 mA or 4-20 mA1 0.015% Rdg + 2 LSD

0-20 mA or 4-20 mA1 0.05% of span

1000Ω @ 24 mA 24V

787: 500Ω @ 24 mA 789: 1200Ω @ 24 mA 24V (789 only)

N/A N/A

0-100 mV or 0-10V N/A

N/A to 40MΩ, 0.2% + 1 LSD

N/A N/A N/A Yes

N/A N/A N/A mA or %

to 19.999 kHz,0.005% + 1 LSD 2.4 V shows diode voltage drop Beeps for resistance <100 ohms Yes

Yes Yes

No No

Yes 789 only

0-30 mA dc 0.001 mA dc 0.05%+2 LSD

Fluke 787 Process Meter • DMM and Loop Calibrator • Backlit LCD • 1000V Overload Protection on V, Ohms, Frequency Fluke 789 Process Meter 787 Features, Plus: • 24V Loop Power Supply • HART™ Mode • Fast “Span Check” Fluke 715 Volt/mA Calibrator • Measure loop Currents and Process Voltages • Source Loop Currents to 24mA • Source Voltage to 10V

705

1

Will over-range to 24 mA

787

L

Fluke 705 Loop Calibrator • Simultaneous mA and % Readout • Fast “Span Check” • Selectable Slow Ramp, Fast Ramp & Step • 24V Internal Loop Supply

L

Fluke Temperature Calibrators

L

TEST EQUIPMENT

712

Fluke 712 RTD Calibrator • Rosemount® pulsed transmitter compatible (pulses >100ms) • Measure temperature from RTD output • Simulate RTD output • Operates with seven types of RTD • Measure additional RTDs using Ohms measurement function • Simulate additional RTDs using Ohms source function • °F or °C selectable • Four shrouded banana jacks

Fluke 714 Thermocouple Calibrator • Measure temperature from TC output • Simulate TC output • Operable with nine types of thermocouples • Calibrate linear TC transmitter with mV source function • Selectable °F or °C • Thermocouple mini-jack termination • Available as accessories: Fluke 700TC1 and TC2 Thermocouple Mini-plug Kits

SPECIFICATIONS Model Fluke-712

Fluke-714

Function Measure/simulate RTD

Range -200 to 800°C (Pt 100)

Resolution 0.1°C, 0.1°F

Accuracy 0.33°C, 0.6°F (Pt 100)

Measure/simulate Resistance Measure/simulate Thermocouple

15 Ω to 3200Ω

0.1Ω

0.1Ω to 1 Ω

-200 to 1800°C, depending on type (K,-200 to 1370°C) -10 to 75 mV

0.1°C or °F (1°C or °F; BRS)

0.3°C + 10 µV

0.01 mV

0.025% mV + 1 count

Measure/simulate

167

Notes Pt; 100 200 500 1000 (385); Pt 100 (392); Pt 100 (392) JIS; Ni 120 (672) 9 TC types; J K T E R S B per NIST 175 and ITS-90 L U per DIN 43710 and PTS-68


Simpson Analog VOM • Industry Standard Model 260 • 36 Measurement Ranges

• Mirrored Scale • CAT III-600V (260-95)

• 10A AC (260-95) • 1000V AC/DC Max (260-8)

ORDERING INFORMATION Description General Purpose, Phenolic Case Relay Protected Roll Top Case Relay-Protected, w/Roll Top Case Yellow ABS Plastic Case Yellow Case, Relay-Protected

SI/12397

Safety VOM Orange, with Case

260-9S

SI/12398 260-9SP

Safety VOM Protected, with Case

ACCESSORIES Cat. # for Model SI/00043 260-8, 8P SI/00125 260-8XI, 8XPI SI/00834 Any 260-8 SI/00805 Any 260-8 SI/00541 260-8XI, 260-8XPI, 9S, 9SP SI/00545 260-8, 8P, 8RT, 8PRT, 95, 95P SI/00425 260-8X, 9

Description Probe Set, threaded w/clips Probe Leads w/Screw-On Alligator Clips Black nylon padded case Black Leatherette case 250A AC Clamp 250A AC Clamp

L 260-8 260-9S

L

(Test Leads Included) Cat. # Model # SI/12388 260-8 SI/12391 260-8P SI/12389 260-8RT SI/12392 260-8PRT SI/12395 260-8XI SI/12396 260-8XPI

Screw-on alligator Clips

Triplett Analog VOM • 58 Ranges & Functions (Model 60-NA) • Withstands 5 Foot Drop • Mirrored Scale

L

• 3 Year Warranty

60

ORDERING INFORMATION TR/3145 Model 60 VOM (Orange Case) TR/3151 Model 60-NA (Gray Case) Carrying Cases TR/10-823 639 Carrying Case (Top Opening) TR/10-2739 639-A Carrying Case (Snap back Cover) TR/4152 639-C Padded Cordura Carrying Case

Test Leads TR/79-373 Miniature Clip Leads (female jack) TR/79-374 48" Test Leads w/ Screw-On Alligator Clips (female jack) AC Amps Clamp-On TR/3264 Model 101-G Line Separator TR/60-211 Model 10 Clamp-On AC AMP Adaptor (60, 60-NA) TR/79-417 6' Attachment Leads (60/ 60-NA to Model 10)

Weschler Columbia AC/DC Clamp-On Tong Test Ammeters

Plug-in Range modules: 0-100A, 0-150A, 0-200A, 0-300A, 0-400A, 0-500A, 0-600A, 0-800A, 0-1000A. The effective range can be lowered by winding two or more turns of the conductor around the tongs.

L

The Tong Test Ammeter reads the true RMS (heating) value, regardless of wave shape. It contains no batteries, rectifiers, switches or electrical windings to overheat or burn out. Currents in lines up to 2300V can be measured if the cables are properly insulated. DC accuracy is 5% of full scale, AC accuracy (25-100Hz) is 2%, except 5% on ranges above 500A. Add 1% for 100-400Hz.

TEST EQUIPMENT

Ideal for verifying currrent in plating tanks, coating systems, welding equipment, motors, generators & transformers Clamp-On Tong Test Ammeters • Instant Readings • One Hand Operation • No Transformers or Shunts Needed

ORDERING INFORMATION for conductors up to 1 1/2" dia. for conductors up to 2 1/2" dia. for conductors up to 3" dia. or bus bars to 4"x1" or 4 1/2"x 1/2" Specify range model(s) when ordering.

Columbia AX Columbia C Columbia D

168


Yokogawa Test Standards Decade Resistance Boxes 2793 6-Dial Decade Resistance Box

2786 Decade Resistance Box

• Resistance value ranges: 0.100 to 1111.210Ω (2793 01) 0 to 111.1110MΩ (2793 03) • Accurate, highly stable • High reproducibility • Resolution 0.001Ω • Well-suited for resistance temperature detector calibration (2793 01) • Well-suited for insulation resistance tester calibration (2793 03)

• Resistance ranges: 0.1 to 111,111Ω (2786 10) 1 to 1,111,110Ω (2786 20) • Small temperature coefficient, little temporal variation • Small residual resistance • Metal casing resists external influences

Wheatstone Bridges 2768 Precision Wheatstone Bridge • Measurement range 0.1Ω to 111MΩ • High precision ±0.01% • Does not require accessories • Built-in power source, current detector; external plug • Highly stable measurement over long periods • Also functions as a variable resistor

2755-97 Portable Wheatstone Bridge • Measurement range 1Ω to 10MΩ • Does not require accessories • Simple operation • Current detector with built-in protection circuit • Compact, light-weight

TEST EQUIPMENT

Double Bridges 2752 Precision Double Bridge

2769 Portable Double Bridge

• Measurement range 0.1Ω to 111MΩ • High precision ±0.03% • Stable over long periods • Standard resistor built-in • Allows testing of cylindrical resistors using clamp device

• Measurement range 0.1Ω to 110MΩ • Rapidly performs reliable, accurate measurements • Easy to handle and store • Does not require accessories • Built-in high sensitivity current sensor

Portable Meters Portable AC Ammeters and Voltmeters

Miniature Portable Ammeters and Voltmeters

• Superior product line • Highly reliable, incorporating 80 years of meter manufacturing technology • Low friction, withstands impact, tautband technology • Compact, light-weight

• Superior product line • Highly reliable, incorporating 80 years of meter manufacturing technology • Low friction, withstands impact, tautband technology

169


Monarch Optical Tachometers

L

• Operating Range up to 25 Feet • Accepts Remote Contact Assembly (optional) • Accepts Remote Sensors (optional) • TTL Pulse Output • Auto Ranging or Fixed Decimal • English and Metric Rates • Tripod Mounting Bushing • On-Target and Low Battery Indicators • Rugged Rubberized Housing • N.I.S.T. traceable Certificate of Calibration

PLT200

PLT200 SPECIFICATIONS Display: Optical Range: Contact Range*: Optical Accuracy: Contact Accuracy*: Resolution: Operating Range: Light Source: Memory: Power: Environmental: Dimensions: Weight:

5 digit alpha-numeric LCD 5 to 200,000 RPM 0.5 to 20,000 RPM (other ranges: inches, yds, miles, cm, m per hour or per second) ±0.01% of reading ±0.05% of reading (RPM) 0.001 to 10 RPM (range dependent) 2 inches to 25 feet Class 3R visible laser Maximum, Minimum and Last (2) AA batteries 5° to 40°C (0° to 100°F) 80% RH up to 31°C (88°F) 6.92 “H x 2.4”W x 1.6”D 7 oz. (210 g)

* with optional Remote Contact Assembly (RCA).

PLT200 is a 32 function Laser Tachometer and Ratemeter/ Totalizer/Counter/Timer (stopwatch). The unit is program– mable in both English and Metric rates. Support is built-in for the optional Remote Contact Assembly (RCA) and plug-in remote sensors. A TTL compatible pulse output can trigger devices like data collectors or stroboscopes. The ergonomic design allows safe, direct line-of-sight viewing of both the target and the display at the same time. The case has a no-slip rubber surface for single hand operation.

PT99 SPECIFICATIONS Display: Range: Accuracy: Resolution:

Dimensions: Weight:

Measurement

• Operating Range up to 36 Inches

L

Operating Range: Light Source: Memory: Power: Environmental:

• Non-Contact Optical

5 digit alpha-numeric LCD 5 to 99,999 RPM 0.01% of reading or ±1 Digit Autoranging: 0.001 to 1.0 RPM Fixed: 1 RPM 2 to 36 inches Red LED Maximum, Minimum & Last (2) AA 1.5 VDC batteries 5° to 40°C (0° to 100°F) 80% RH up to 31°C (88°F) 6.92"H x 2.4"W x 1.6"D 7 oz. (210 g)

PT99

• Rugged, Ergonomic Rubberized Housing

• Tripod Mounting for Hands Free Operation

• Autoranging or Fixed Decimal Direct line-of-sight viewing of both the rotating target and the display at the same time. TEST EQUIPMENT

ORDERING INFORMATION Catalog No. MODEL MN/6125-010 PLT200 MN/6125-011 PLT200 KIT MN/6109-010 PT99 Accessories for PLT200 MN/6180-057 ROS-P MN/6180-057-25 ROS-P-25 MN/6180-017 MT-190P MN/6180-020 IRS-P MN/6180-028 EC-25P MN/6280-037 CA-4044-6 MN/6180-074 RCA MN/6580-010 CTE MN/6580-011 12" Contact Wheel Accessories for both models MN/6180-047 CC-10 MN/6180-048 CC-11 MN/6180-070 T-5

DESCRIPTION Pocket Laser: Tachometer/Timer/Totalizer with N.I.S.T. traceable certificate of calibration and 12" of reflective tape. Pocket Laser Tachometer Kit includes: Tach, RCA, Carrying Case, N.I.S.T. certificate and 5 ft roll of T-5 reflective tape. Pocket Tachometer with 12" of reflective tape Remote Optical Sensor with 8-foot cable, mounting bracket and 12" of reflective tape. Remote Optical Sensor with 25-foot cable, mounting bracket and 12" of reflective tape. Magnetic trigger Sensor/Amplifier with 8 foot cable Infrared Sensor with 8 foot cable, 3.5 mm plug and mounting bracket 25 foot extension cable for all sensors 6 foot input/output cable, 1/8 inch mono phone plug to BNC connector Remote Contact Assembly includes contact tips (concave and convex) and 10 cm linear contact wheel. Rubber concave, convex tips and 10 cm contact wheel Linear Contact Wheel with 12-inch circumference for use with RCA. Padded Pouch Latching Plastic Carrying Case. Reflective Tape 5 foot roll, 0.5 " wide

170


Extech Tachometers Combination Laser Tach & IR Thermometer

SPECIFICATIONS Display Range

• Buit-in laser thermometer measures surface temperature of moving parts • Fixed 0.95 emissivity, 6:1 distance to target ratio • Non-contact photo tach measures to 6.5ft (2m) • Contact tach for RPM & linear speed • Min/Max/Last memory • Complete with tips/wheel, AA batteries, reflective tape, carrying case RPM10

99999 counts

rpm

10 to 99999 photo 0.5 to 20000 contact

ft/min

L

Contact/Laser Photo Tachometer • Laser guided non-contact measurements to 6.5ft (2m) • Characters on display reverse for easy reading (photo/contact mode) • Hold button stores last reading for 5 minutes • Min/Max memory • Complete with wheels, AA batteries, reflective tape, carrying case 461995

0.2 to 6560

m/min Accuracy Resolution Laser

0.05 to 1999.9 ±0.05% ±1d 0.1 rpm -4 to 650°F / -20 to 315°C (RPM10 only)

Dimensions

8.5 x 6.1 x 1.5" (216x66x38mm)

ORDERING INFORMATION

L

EX/RPM10

Combination Tachometer + IR Thermometer

EX/461995

Contact/Laser Tachometer

EX/461937

Reflective Tape 10pcs 1/4"x23"

EX/461990

Contact Wheels (cone tip, flat tip)

TEST EQUIPMENT

Extech Light Meters

Model EA30 Wide Range Light Meter • Measures up to 40,00Fc & 400,000Lux • Large display with bargraph • Relative function for zero or difference from reference value • Peak captures light pulses to 100ms • Data hold & Min/Max store • Complete with AAA batteries, light sensor and protective cover with 39" (1m) cable, built-in stand, protective holster & carrying case

Model EA31 EasyView® Big Digit Light Meter • • • • •

Measures up to 20,000Fc/20,000 Lux 0.01Fc /0.01Lux resolution 2000 count display with bargraph Data hold & Min/Max store Complete with AAA batteries, light sensor and protective cover with 39" (1m) cable, built-in stand, protective holster & carrying case

Model 407026 Heavy Duty Light Meter with PC Interface Enhance accuracy by selecting one of four lighting types plus PC interface • % displays differential from reference point • “ZERO” Re-Calibration • Selectable lighting type Tungsten/Daylight, Fluorescent, Sodium, Mercury • Data hold, Min/Max/Avg readings • Auto power off • Optional Data Acquisition software (407001) and Datalogger (380340) • Complete with 9V battery, light sensor and protective cover with 3.8ft 1.2m) cable, and protective holster with stand. Optional 117V or 220V AC adaptors.

ORDERING INFORMATION

SPECIFICATIONS Model Display counts: Range: Fc Lux Max. Resolution: Basic Accuracy: Cosine & Color Corrected: RS-232 Interface: Datalogging: Dimensions:

171

EA30 4000 (LCD) 40, 400, 4000, 40000 40, 400, 4000, 40000,400000 0.01Fc/0.01Lux ±3% rdg ±0.5% FS Yes — —

407026 2000 (LCD) 200, 2000, 5000 2000, 20000, 50000 0.1Fc/Lux ±4% FS Yes Optional 407001 Optional 380340

5.9 x 2.8 x 1.4" (150x72x33mm)

7 x 2.9 x 1.3” (178x74x33mm)

EX/EA30 EX/EA31 EX/407026 EX/407001 EX/156119 EX/409997 EX/407001 EX/380340

Wide Range Big Digit Lightmeter Big Digit Lightmeter Heavy Duty Lightmeter Data Acquisition Software & Serial Cable for 407026 117VAC Adaptor for 407026 Large Soft Vinyl Pouch Carrying Case for 407026 Data Acquisition Software & PC Serial Cable Data Logger w/8000 Reading Storage, PC Software, Serial Cable


Bacharach Combustion Analyzers & Leak Detectors Carbon Monoxide Analyzer

Combustion Analyzer

• Measures CO with 1ppm resolution • Highly visible digital display with backlight • Probe and hose assembly for flue gas testing • Optional IrDA printer

• Measures O2, stack temperature, CO • Calculates CO2, combustion efficiency, excess air, CO free air • Low cost, easy to use • 2 year warranty

L

L

Fyrite Tech 60

Monoxor III

SPECIFICATIONS Range: Accuracy: Probe: Warm Up: Display: Power: Printer Port: Size & Wgt: Warranty:

0 - 2000 ppm ± 5% of reading or 10 ppm, whichever is greater 1000°F (538°C) max at 5" insertion 60 seconds Four-digit LCD display w/backlight 4 AA Alkaline batteries (18 hour life) Wireless, IrDA or HP protocol 7.5 x 3.1 x 2.1" (16 oz. with batteries) 2 years, including sensor

Combustible Gas Leak Detector • Visual & audible indicators • 2 sensitivity levels • 12" probe with plug-in sensor • Automatic calibration • UL913 classification

L

SPECIFICATIONS Variable rate flashing red, variable speed audible ticking 20ppm in high mode, 50ppm in low mode 60 seconds, flashes green when ready 4 AA alkaline batteries (14 hours life) 0-40°C operating Handheld, 6 x 2 x 1.5" (6oz) UL913 Class I, Div 2, Group A,B,C,D locations

L Informant 2

L Tru Pointe

Variable intensity audible & visual 0.1 oz/yr for R134a (hardest to detect) 1 yr of normal use (150 hours) 14" flexible, with plug-in sensor 2 D alkaline batteries (8-13 hr life) 2 x 9.4 x 2.5" (1.2 lbs with batteries) UL listed to SAE J1627

Sensor: Sensitivity: Warm-up: Power: Size & Wgt: Approvals:

Audible, sequential LEDs & flashing probe tip All CFC, HCFC & HFC refrigerants, all combustible gases & vapors Located at probe tip for fast response & quick changeover 0.25 oz/yr of R134a (hardest to detect), 50ppm of methane 10 seconds 4 AA alkaline batteries (5 hr life) 1.8 x 9.7 x 2.3" with 20" probe UL listed to SAE J1627, MET lab certified to UL913, intriniscally safe for Class 1, Div. 1, Group D hazardous locations

Includes batteries, refrigerant & gas sensors, sensor tips, filters and carrying case.

ORDERING INFORMATION BA/19-8104 BA/24-8217 BA/19-7075 BA/19-8038 BA/19-8106

Monoxor III CO Analyzer Fyrite Tech 60 Combustion Analyzer Leakator Jr. Combustible Gas Leak Detector Informant 2 Dual Detector Contractor Kit Tru Pointe Refrigerant Leak Detector

172

TEST EQUIPMENT

Indicators: Detection:

SPECIFICATIONS Indicators: Sensitivity: Sensor Life: Probe: Power: Size & Wgt: Approvals:

Dual Purpose Leak Detector • Detects refrigerants & combustible gases • Swap sensors in seconds • Sensitivity automatically adjusted • 0.2" probe tip fits into tight spaces • Filter prevents moisture contamination • Dual LED displays for easy viewing • Optional rubber boot holds flashlight

SPECIFICATIONS

Refrigerant Leak Detector • Detects all CFC, HFC & HCFC refrigerants • Patented heated diode sensor • Visual & audible indicators • Automatic zero & background correction • 2 sensitivity levels

Measur ement Ranges Flue Gas: 0 to 999°F (-18 to 537°C) Ambient: 32 to 212°F (0 to 100°C) Oxygen: 0.0 to 20.9% O2 Carbon Monoxide: 0 to 2000 ppm CO Calculat ed Ranges Combustion Efficiency: 0.1 to 99.9% Carbon Dioxide: 0.0 to a fuel dependent maximum (in %) CO Air Free: 0 to 9,999 ppm Excess Air: 0 to 400% Selectable Fuels: Natural Gas, Oil #2, Propane, Kerosene Power: 4 AA alkaline (18 hours life) Size & Wgt: 7.5 x 3.1 x 2.1" (16 oz. with batteries) Includes angled probe with 5.5' hose, batteries & carrying case.

Leakator Jr.

Indicators: Sensitivity: Warm-up: Power: Temperature: Size & Wgt: Safety:

SPECIFICATIONS


Megger® Hand-Held TDR / Cable Length Meter • • • • • • •

Measures length of power, telephony, CATV & LAN cables Determines distance to an open or short Automatic impedance control (25, 50, 75, 100, 125, 150W) Internal library of 39 standard cable types Memory for 20 custom cable settings Tone generator for cable tracing Large, high resolution backlit LCD display

Additional Features: Cable Calibration function allows measurement of V.O.P. (Velocity Of Propagation) in a known cable length. Requires at least a 30ft (10m) sample. Line Voltage Detection feature displays "OUCH" message and stops operation if voltage exceeds 6.5V.

SPECIFICATIONS Range:

Resolution: V.O.P. Connector: Power: Battery Life: Operating Temperature: -18°C to 60°C * at 20°C for coax cables <8000 ft, telephony cables <6000 ft, wiring <3000 ft

L

Accuracy*:

12000 ft (3.7km) at 99.9 V.O.P. 9800 ft (3.0km) at 80.0 V.O.P. 8000 ft (2.4km) at 66.0 V.O.P. 6200 ft (1.9km) at 50.0 V.O.P. ±2% of rdg ±20" at <300 ft ±2% of rdg at >300 ft 20 inches (50cm) adjustable from 1.0% to 99.9% of the speed of light BNC 4 AA batteries 5000 tests

TDR-900

Supplied with soft carrying case and alligator clip adapter.

ORDERING INFORMATION ME/TDR900

Hand-Held TDR/Cable Length Meter

Megger® Hand-Held TTR SPECIFICATIONS

L

TEST EQUIPMENT

Excitation Voltage:

TTR20

8 V rms for testing distribution or power transformers & PTs; 0.5, 1.5, or 8 V ac rms for testing CTs (switched automatically if current exceeds a preset value) Test Frequency: 55 Hz Excitation Current: Range 0 to 100 mA, 4-digit resolution Turns Ratio Range: 0.8 to 10000, 5-digit resolution Transformer Polarity: Normal or reversed Current Accuracy: 2% of reading ±1 digit Turns Ratio Accuracy: 0.1% (0.8 to 2000) 0.15% (2001 to 4000) 0.25% (4001 to 10,000) Measuring Time: Less than 5 seconds Measurement Method: ANSI/IEEE C57.12.90 Phase Relationship: ANSI C57.12.70-1978 Display: Graphic LCD, adjustable back-lighting Safety/EMC/Vibration: IEC-1010-1, CE and ASTM D999.75 Operating Temperature: -20º C to 55°C (-5°F to 130°F), < 90% RH non-condensing Power: Six standard AA alkaline batteries Battery Life: 12 hours of field operation Dimensions: 9.5"H x 4.5"W x 1.9"D (240x115x50 mm)

• Single- and three-phase transformer testing • Fully automatic; fast; easy-to-use; robust; lightweight • Battery powered • Tests turns ratio, excitation current and polarity • Simple, one-button operation • Quick-start guide on front panel

173

ORDERING INFORMATION ME/TTR20 Optional Accessories ME/35942 ME/36013 ME/35755-1 ME/35788

Handheld TTR with 6ft (1.8m) test leads Test leads, X/H winding, 12ft (3.6m) Test leads, X/H winding, 20ft (6m) Battery/line power thermal printer with paper, battery pack, charger, interface cable Semi-hard fabric transport case


Simpson Sound Level Meters • 40-140 dB Range • Portable, Easy to Operate • AC and DC Recorder Outputs • 40 Hour Battery Life • Includes Padded Carrying Case

886-2 •Fast or slow response •Tripod mount and analog meter •Detachable microphone •Meets ANSI S1.4-1983; ANSI SI.4-1992 •Frequency = 1000 Hz at 94dB on 90dB range •“A”, “B”, “C” ext. filter for flat response

Two full-function general purpose sound level meters offer an easy-to-use, convenient way to meet OSHA and Walsh-Healy noise control specifications.

884-2

L 886-2

• Identical to the 886-2 but only offers “A” weighting which closely corresponds to the human ear

890 Calibrator The 890-2 provides a constant 94dB or 114dB sound pressure level at 1 KHz.

ORDERING INFORMATION SI/40003 SI/40004 SI/40006 SI/40007 SI/12890

884-2 Sound Level Meter 886-2 Multi-Weight Sound Level Meter 884-2 with 890-2 Calibrator 886-2 with 890-2 Calibrator 890-2 Sound Level Calibrator, 1" Microphone

SI/00198 SI/00183 SI/00184 SI/45022

25' Microphone Cable for 886-2 Microphone for 886-2 Tripod Mount for 886-2 Microphone Case, Molded Plastic

Extech Testers Battery Powered Milliohm Meters

Battery Capacity Tester • Checks battery condition in seconds while the battery is in service • Simultaneously measures battery resistance and voltage • Built-in datalogger stores up to 999 tests Includes PC interface cable and software, test leads and AAA batteries

Complete with AA batteries, leads with 4 alligator clips, leads with 2 Kelvin alligator clips

L 380580

SPECIFICATIONS Range

Resolution

Current

Accuracy

200mΩ

0.1mΩ

100mA

±(0.5% +2d)

2000mΩ

1mΩ

100mA

±(0.5% +2d)

20Ω

0.01Ω

10mA

±(0.5% +2d)

200Ω

0.1Ω

10mA

±(0.5% +2d)

2000Ω

1Ω

100mA

±(0.5% +2d)

Dimensions:

9.8 x 7.5 x 4.3" (250x19 x110mm)

L BT100 TEST EQUIPMENT

• Four terminal Kelvin measurements • Resolution to 100µΩ • 20V test voltage • Large LCD display • Invalid test indicators • Auto-Hold and Auto-Off features • Built-in water resistant case with shoulder strap

SPECIFICATIONS Resistance Ranges: 40mΩ, 400mΩ, 4Ω, 40Ω Resistance Accuracy: ±(1% reading + 8digits) Voltage Ranges: 4V, 40V Voltage Accuracy: ±(0.1% reading + 6 digits) Display: 4000 count LCD, dual readout Input Voltage: 50VDC max. Battery Life: 7 hours Dimensions: 9.75" x 4" x 1.75" (250 x 100 x 45 mm)

ORDERING INFORMATION EX/380580 EX/BT100 EX/BT102

Battery Powered Milliohm Meter Battery Capacity Tester 120V AC Adapter for BT100

174


Hioki Testers MULTI-FUNCTION DMMS

VOLTAGE DETECTOR

AC/DC Voltage & Current Resistance & Continuity 9999 count LCD display Min/Max, Average & Relative values • 4-20 mA measurement converts to 0-100% display • Optional RS-232C package for PC data transfer

L

• • • •

3804

L

4 ranges, 999.9mV to 999.9V (±0.3% rdg ±2d) 4 ranges, 999.9mV to 999.9V (±1.2% rdg ±5d) 40-500Hz 6 ranges, 400.0Ω to 40.00MΩ (±0.6 % rdg. ±3d) 6 ranges, 400.0µA to 10.00A (±0.2 % rdg. ±3d) 6 ranges, 400.0µA to 10.00A (±1.2 % rdg. ±5d) 50-2kHz Capacitance, Data hold, continuity (<10Ω), diode check 3805: TRMS AC, freq to 50kHz, J&K thermocouples Auto or Manual 41 segment 3/sec (digital), 13/sec (bar) 3" x 6.6" x 1.3" (76x167x33mm) Test leads 3851-10, holster, battery

Ranging: Bar Display: Sample Rate: Dimensions: Accessories:

Voltage Range: Indication: Battery Check: Operating Temperature: Standards: Dimensions:

• Slim Body for Easy Clamping in Narrow Spaces • Independent-opening Double-lever Jaw • Right or Left Hand Operation • 4199 Count LCD • True RMS Measurement (3280-20)

4-Digit DMM 4-Digit TRMS DMM

SPECIFICATIONS Function AC Amps:

3129

SPECIFICATIONS Detection Method: Voltage Range: Max. Wire Size: Standards: Dimensions: Lead Length:

Electrostatic induction 70-600VAC, 50/60Hz 0.67" (17mm) dia., insulated wire Cat III, 600V 2.76"W x 2.95"H x 1.18"D 27" (0.7mm)

ORDERING INFORMATION HK/3120 HK/3129 HK/3246 HK/3280-10 HK/3280-20

175

Voltage Detector, batteries included Phase Detector, with carrying case & AA batteries Pencil HiTester, battery included Clamp-On HiTester, with leads, battery & carrying case TRMS Clamp-On HiTester, with leads, battery & carrying case

®

3280-20

L

TEST EQUIPMENT

L

PHASE DETECTOR

• LED & Buzzer Indicate Phase Direction • No Electrical Connection • Live Wire Check (R-S, S-T) • Battery Check & Auto Shut Off

70-600VAC, 50/60Hz Red LED and continuous beep Green LED 0 to 40˚C, <80%RH (non-condensing) CAT IV 600V, indoor use 5.9"L x 0.7"dia (149 x 18.5mm)

CLAMP-ON HITESTERS

ORDERING INFORMATION HK/3804-50 HK/3805-50

• Detect AC Voltage in Insulated Wires SPECIFICATIONS

SPECIFICATIONS DC Volts: AC Volts: Ohms: DC Current: AC Current: Other Functions:

3120

DC Volts: AC Volts: Ohms: Continuity: Wire Size: Allowable Current: Overload Protection: Operating Temperature: Standards: Dimensions:

Range (Accuracy) 3280-10: 42 / 420 / 1000A (50/60Hz; ±1.5% rdg ±5 d), 3280-20: 42 / 420/ 1000A (45-66Hz: ±1.5% rdg ±5d) (40-45Hz or 66Hz- 1kHz: ±2.0% rdg ±5d) 420m / 4.2 / 42 / 420 / 600V (±1.3%rdg ±4d) 4.2 / 42 / 420 / 600V (50-500Hz, ±2.3%rdg ±8d) 420 / 4.2k / 42k / 420kΩ (±2.0% rdg ±4d), 4.2MΩ (±5.0 rdg ±4d), 42MΩ (±10.0% rdg ±4d) 420Ω (±2.0% rdg ±6d), buzzer <50Ω 1.3" (33mm) max diameter 2000A AC rms max continuous DCV/ACV: 600V DC/AC rms; Ω/Continuity: 250V DC/AC rms 0 to 40˚C, <80%RH (non-condensing) CAT III 600V(AC A), CAT II 600V(AC/DC V) 2.2"W x 6.9"H x 0.6"D


WESCHLER INSTRUMENTS Manufacturer Index Only a few products from each manufacturer are listed in this catalog. Call for information on any products not shown. Manufacturer

page

A&M/Weston Meters

74

Action Instruments Signal Conditioners/Isolators Wireless I/O Adalet Enclosures

80-82, 85, 88a 137

NEW

AEMC Dataloggers Flexible Current Probe Ground Resistance Testers Megohmmeters Power Analyzers Alaron Vibration Transmitters Altek Calibrators Amprobe Power Quality Recorders

136

123-124 157 159 157-158 150-151

111a

163-164 120

Manufacturer

page

Conzerv Power Meters

33-34a

Crompton (Tyco) Meter Relays, Analog Panel Meters, Analog Power Meters, Digital Protection Relays Switchboard Meters, Analog Transducers Dixson Bargraph Meters

14

EIL Meters, Transducers

see Weschler

Electro Industries Power Meters, Digital EMON DMON Energy Meters

26, 29a-b

NEW

Empro Shunts

API (Absolute Process Instruments) Signal Conditioners 88

ENM Hour Meters & Counters

Ashcroft Pressure Gauges, Analog Pressure Gauges, Digital Pressure Switches

Bacharach Combustion Analyzers Leak Detectors

172 172

Extech Battery Testers Clamp Meters Controllers Dataloggers DMMs Humidity Meters Infrared Cameras Infrared Thermometers Light Meters Milliohmmeters Power Supplies Recorders Sound Level Meters/Loggers Tachometers Thermometers

Beede Meter Relays, Analog

79c

Flexcore Current Transformers

ATC (Westcon/Diversified) Counter/Timers Photoelectric Sensors Power Alert Tachometer Generators ATS Clocks/Timers

Beta Control Switches Instrumentation Switches

187

108 107, 108a 108a

41 117 138a 118

130

see Martel 134

Fluke Clamp Meters DMMs Infrared Thermometers Leakage Meters Megohmmeters

77-78 69-72 24-25 131-132a 51-54 100-102

30-32

90

129

174 126, 145 6 125-126 142 125 127 152 171 174 133 125 126 171 125

92

143, 147 140-141 153 147 154

Manufacturer

page

Fluke (continued) Oscilloscopes Power Analyzers Process Calibrators

139 151a 167

Fuji Electric Controllers Recorders

7-8 121a

Hioki Battery Testers Clamp Meters Current Monitor Dataloggers DMMs Megohm Meters Meter Relays, Analog Phase Detector Power Monitors, Analyzers Recorders Testers, Electrical

161 175 149 122 175 154 79 175 147, 149 119, 121, 123 175

Hoyt Panel Meters, Analog

73, 75

Ideal Clamp Meter

146

Instrument Transformers AC Current Transducers AC Current Transformers International Instruments Edgewise Meters, Analog Jewell Panel Meters, Analog KEP Batch Controller Counter/Timers Kobold Flow Sensors Level Transmitters Temperature Transmitters

95 91

57-57a

62-62a, 66-66a

9 42-42b

111a, 115-117 111 109, 115

Laurel Counters Panel Meters, Digital Transmitters

39 22 88

LFE Meter Relays, Analog Panel Meters, Analog

79-79b 74


WESCHLER INSTRUMENTS Manufacturer Index Only a few products from each manufacturer are listed in this catalog. Call for information on any products not shown. Manufacturer London Electronics Clocks/Timers Displays Ethernet Converter Panel Meters, Digital Madison Annunciators Switches Martel Panel Meters, Digital Power Supplies Process Calibrators (Beta) Megger/Biddle Clamp Meters Ground Resistance Testers High Pot Testers Insulation Resistance Testers Leakage Testers Low Resistance Testers TDR/Cable Tester TTR/Transformer Tester Metermaster Panel Meters

page NEW 38 38 138 24, 38

138a 138b

36-37 133 166

146 160-161 162 155-156 146 162 173 173

see Weschler

Manufacturer NLS Panel Meters, Digital Signal Conditioners Noshok Pressure Transducers Partlow Chart Recorders Controllers Pyragon I/O Modules Signal Isolators Temperature Transmitters Pyromation RTDs Thermocouples Thermowells Raytek Temperature Sensors Selco/Asahi Panel Meters, Digital Signal Conditioners/Isolators

page 35 85-85a

105-106

121 10

87 86 85-86

113 112 136

Manufacturer

page

VAS/Doric Panel Meters, Process Calibrators

call

Veris Current Switch/Relay KW Transducers

103 103

Weschler Bargraph Controllers Bargraph Meters Current Transformers Enclosures/Assemblies Loop Splitter Panel Meters, Analog Power Meters, Digital Shunts Switchboard Meters, Analog Tong Test Ammeter Transducers Transformer Monitors Viscosimeters Voltage Transformers

110-111

23 82a, 83

West Controllers Recorders

NEW

Westcon Midwest Transformer Current Transformers Modutec Monarch Tachometers Speed Sensors National Meter KW Hour Meters

call see Jewell

138b, 170 118

34b

Simpson Counter/Totalizers Elapsed Time Meters Meter Relays, Analog Panel Meters, Analog Panel Meters, Digital Power Meters Sound Level Meters VOMs

40 127 76 61, 65, 68 20-21 26 174 168

Texmate Panel Meters, Digital

15-19

Newport Controllers Digital Panel Meters Load Cells Rate Total

8a, 10c 23a-23b 118a 42b

Transmation

NK Technologies AC Current Transducers Current Switches DC Current Transducers Ground Fault Sensors

99 95, 104 89 95

Vaisala CO2 Detectors

188

Triplett Panel Meters, Analog VOMs

Humidity Transmitters

4-5 4, 11-13 93-94 135-136 87 55 4, 12-13 89 43, 55 168 96-98 138 138 92

see Pyragon

75, 79d-e 168

113 113-114

Westinghouse Switchboard Meters Yokogawa Clamp-on Testers Controllers Data Loggers Edgewise Meters, Analog Elapsed Time Meters Insulation Testers Loop Indicators Panel Meters, Analog Portable Meters Power Meters, Analog Power Meters, Digital Power Monitors Process Calibrators Resistance Bridges/Boxes Switchboard Meters, Analog Switchboard Meters, Digital Thermometers

9 122 see ATC

see Weschler

144, 148 5, 6a 120 56-56a 128 153 37 58-60, 64, 67 169 48-49 27-29 148 165 169 44-50, 56 27-29 153a


Product Index Only a few products from each manufacturer are listed in this catalog. Call for information on any products not shown. All test equipment is listed under the Test Equipment heading. Product A Alarms Ammeter, Portable Ammeter Shunts Analog Meters, Illuminated Analog Panel Meters Analog Switchboard Meters Annunciators Assemblies, Instrument B Bargraph Meters Battery Monitor BCD Output C Camera, Infrared Chart Recorders Clocks CO, CO2 Detectors Controllers Analog Batch Current/Voltage Humidity Limit pH RTD, TC Process Temperature Converters, Ethernet Counters Current Shunts, DC Current Switches Current Transducers, AC Current Transducers, DC Current Transformers D Dataloggers Clamp-on Humidity Power Sound Temperature Voltage/Current Demand Meters Digital Panel Meters Mini Large Display Process DIN Meters, Analog DIN Meters, Digital E Edgewise Meters, Analog Edgewise Meters, Digital Elapsed Time Meters Enclosures Energy Meters

189

page 80, 88a 169 89-90 45-47, 57, 62, 66, 73, 75 55, 58-75 43-57 138a 134 4, 11-14, 19 37, 129 18, 35 127 119, 121, 125 24, 38, 130 113, 172 76-79 9 4-7, 10-10a 8a 5, 10 4 4-10a 4-10a 4-10a 138, 138a 4, 11, 17, 19, 24, 38-42b, 129, 130 89-90 103-104, 134 95-100 89, 98, 101 91-94

124, 126 122, 125 120, 126 126 120-122, 125 120, 122-124, 126 24, 26, 29, 31, 32a, 34-34a 4, 11-29, 33-42 18, 35-37 4, 12-13, 38 4, 11-24, 35-42 71-72 11, 15-26, 29, 33-34, 39-40, 42 55-57, 74 11-14 37-38, 70-71, 127-128, 130 135-136 26, 29-34b

Product

page

Ethernet 4, 9, 15, 23b, 24, 26, 29-30, 85, 114, 119-120, 122, 138-138a Event Counters 24, 39-42, 129-130 F Float Switches Flow Sensors Freqency Meters, Digital Frequency Meters, Analog Frequency Transducers

138b 111a, 115-117 4, 11-13, 15-19, 21, 23-24, 27, 39-42 43-44, 49, 51, 54-55, 58, 67-72 80-81, 84-85, 87-88a, 96, 100

G Generators, Tach Ground Fault Sensors

118 95

H HART Protocol Hour Meters Humidity Meters Humidity Transmitters

82, 85, 86, 166-167 37-38, 69, 71, 127-130 122, 125 113-114

I Infrared Sensors Isolators K Kilowatthour (KWH) Meters L Large Display Meters Level Transmitters Limit Switches Load Cells Load Cell Meters Loop Isolators Loop Power Supplies Loop Powered Indicators Loop Splitters M Meters, Analog Edgewise Elapsed Time Frequency Illuminated Power Relays Ruggedized Switchboard Temperature Voltage/Current Meters, Digital Bargraph Counters Elapsed Time Energy Frequency/Rate Large Display Loop Powered Power Process

110-111 80-88a, 98 24, 26, 29-34b, 53 4, 12-13, 38, 130 111 103-104 118a 4, 11, 15-17, 22-24 80-88 133 19, 37 86

55-58, 74 69-71, 130-132 43, 44, 49, 51, 54-55, 58, 67-72 45-47, 57, 62, 66, 73, 75 43-44, 48-49, 53-54 76-79c 43, 58, 73-75 43-57 43, 77 43-47, 50-52, 54-66, 69-75 4, 11-14, 19 4, 11, 17, 19, 24, 38-42b, 129-130 37-38, 129-130 26, 29-34b 4, 11-13, 15-19, 21, 23-24, 27, 39-42b 4, 12-13, 38, 130 19, 37 4, 12-13, 15-17, 24-29a, 33-34b 4, 11-24, 35-42a


WESCHLER INSTRUMENTS Product Index Only a few products from each manufacturer are listed in this catalog. Call for information on any products not shown. All test equipment is listed under the Test Equipment heading. Product

page

Product

Meters, Digital (continued) Pressure/Load 4, 11, 15-19, 22-23b, 38 Resistance/Potentiometer 4, 11, 15-20, 23-24 Switchboard 4, 11-14, 25-29 Tachometer 4, 11-13, 15-19, 39-40 Temperature 4, 11-24, 36-38, 130 Voltage/Current 4, 11-24, 35-38 Watt/VAR/Phase/PF 4, 12-13, 24-29, 33-34 Meter Relays, Analog 76-79c Modbus 4-5, 7-10, 15-17, 22, 24, 26, 29-30, 32a, 34-34b, 39, 84, 88, 102-103, 114, 120-122, 132a, 138 Motor Load Meters 67, 71

Signal Repeaters/Isolators Speed Sensors Splitter, Loop Strain Gage Meters Strain Gauge Transmitter Sub-Metering Switchboard Meters Analog Digital Switches, Current Switches, Instrumentation Synchroscopes

O Optical Sensors Overload Ammeters

T Tach Generators Tachometers, Panel Temperature Controllers Meters, Analog Meters, Digital Sensors Transducers Transmitters Thermowells

P Panel Meters, Analog Panel Meters, Digital pH/ORP Meters Photoelectric Sensors Potential Transformers Power Meters, Analog Power Meters, Digital Power Supplies Power Transducers Pressure Gauges Pressure Meters, Direct Pressure/Load Meters Pressure Switches Pressure Transmitters Process Indicators, Loop Powered Protector Relays Proximity Sensors R Rate Meters Recorders Relays, Meter Relays, Protection Relays, Current Remote Displays Resistance Meters, Digital RF Ammeters RTDs

117-118 71 58-75 11-29, 33-42 4, 17, 23a 117 92 43-44, 48-49, 53-54 4, 12-13, 15-17, 24-29, 33-34 80, 82, 125 97, 101-103 107-108a 4, 15-17 4, 11, 15, 22-23, 38 108a 105-106a 19, 37 131-132a 117 38-42b 119-123, 125 76-79c 131-132 103-104 18, 24, 38 4, 11, 15-20, 23-24 55, 74 113

S Sensors CO2 Flow Humidity Infrared Level Photoelectric Position Pressure Speed Temperature Shunts, DC Signal Conditioners

113 115-117 113-114 110-111 111 117-118 117 105-108a 118 109-114 89-80 80-88a

page 80, 82-83, 86 118 86 4, 11, 15-18, 22-24 80-81, 84-85 30-32 43-57 4, 11-14, 25-29 103-104, 134 134 43, 49, 53 118 4, 11-13, 17, 19, 24, 39-40, 42 4-10 43, 77 4, 11-24, 36-38, 130 109-114 101 80-82, 84-87, 109, 113-115, 137 136

Test Equipment Ammeter, Portable 169 Battery Testers 161, 174 Cable Length 173 Calibrators 163-167 Chart Recorders 119-125 Clamp Meters 124, 126, 143-147, 159, 161, 168, 175 Combustion Analyzer 172 Current Monitor 149 Current Probe (Flexible) 157 DMMs 140-142, 175 Ground Resistance Testers 159-161 High Pot Testers 162 Humidity Meters 125 Infrared Meters 127, 142, 145, 152-153 Insulation Resistance Testers 153-158 Leakage Testers 146-147 Leak Detector (Refrigerant) 172 Light Meters 171 Low Resistance Testers 162, 174 Megohmmeters 153-158 Milli & Micro-ohmmeters 162, 174 Multimeters 140-142, 175 Oscilloscopes 139 Phase Rotaton Detectors 175 Power Monitors/Analyzers 126, 147-151a Power Supplies 125 Process Calibrators 163-167 Resistance Bridges 169 Resistance Decade Box 169 Sound Level Meters 126, 174 Tachometer/Strobe 138b, 170-171 TDR 173 Temperature Calibrators 163-167 Temperature Meters 125, 140-142, 145, 153a

190


Product Index Only a few products from each manufacturer are listed in this catalog. Call for information on any products not shown. All test equipment is listed under the Test Equipment heading. Product

page

Test Equipment (continued) Test Standards 169 Thermal Imager 127 Transformer Ratio Testers 173 Voltmeter, Portable 169 VOMs (Analog) 168 Thermocouples 112 Timers 37-39, 42-42b, 127-130 Totalizers 39-42b, 130 Transducers AC Current 80, 82a, 88a, 95-100 AC Voltage 80, 82a, 84-85, 88a, 96-98, 100 DC/DC 80-84, 87, 88a, 89, 98 Frequency 80-81, 85, 87-88a, 96, 100 Potentiometer 82a, 85, 88a Power 97, 101-103 Temperature 80-82a, 84-87, 88a, 101 Transformers Current 91-94 Voltage 92 Transformer Monitors 138 Transmitters Frequency 88-88a Isolating 80-88a Level 111 Pressure 105-107 Process 80-88a, 137

Product Serial Temperature Vibration Trip Relays

page 88 80-82, 84-87, 88a, 109, 113-115, 137 111a 95, 103-104, 131-132a

U Universal Transmitters Utility Billing Meter

86-87 29b

V Vibration Transmitters Viscosimeters VAR Transducers Voltage Transducers Voltage Transformers Voltmeter, Portable

111a 138 97-98, 101-102 82a, 88a, 96, 100-101 92 169

W Watt Transducers Watthour Meters Watt/VAR Meters Analog Digital Wireless Z Zahn Cups

96-98, 101-103 24, 26, 29-34b, 53 43-44, 48-49, 53-54 4, 12-13, 15-17, 24-29a, 33-34 31, 137 138

Weschler General Terms Where to Order Corporate Office

Weschler Instruments 16900 Foltz Parkway Cleveland OH 44149 phone: 440-238-2550 toll free: 800-557-0064 fax: 440-238-0660 email: sales@weschler.com web: www.weschler.com

Sales Offices in NY, FL, TX & OH. Any of these offices can be reached through our main phone system. phone: 440-378-6580 toll free: 800-903-9870 fax: 585-349-0837 toll free fax: 800-903-9590 email: info@weschler.com

How to Order Orders may be placed to the corporate office or any of our local sales offices. Our customer service hours are 8:00 AM to 7:00 PM Eastern time. For customers with established credit accounts, invoices are due in full in 30 days. New accounts are invited, with suitable bank and vendor references. MasterCard, Visa or American Express credit cards may also be used, or payment may be made on wire transfer. Minimum order is $50. All prices are quoted in US$. We will be pleased to furnish quotations by mail, email, telephone or fax. Quantity discounts are available on many of the items shown in this catalog. To avoid duplication of telephone orders, please mark confirming orders clearly. Prices are FOB shipping point. Unless other arrangements are made, freight and handling charges will be prepaid and added to the invoice. Regardless of shipping method, title passes at point of shipment. Claims for loss or damage must be made to the carrier. Warranty The warranty period and coverage varies by product. Weschler manufactured items are warranted against defects in material and workmanship. We will, at our option, repair or replace an item we verify to be defective during the warranty period. For items we distribute, the manufacturer's warranty applies. Returns Authorization must be obtained from Customer Service before returning items for any reason. Please provide reason for return, date of purchase, and our order number. Returns may be subject to a restocking charge.

191