Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS
Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS

Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS

$5,295.99 Sale Save

Only 0 left in stock

Eaton 9PX 9PX5KTF5 5kVA/4.5kW 208V w/120V Output Transformer Module UPS 

Eaton 9PX 9PX5KTF5 Specifications:
General
Topology Double-conversion online
Configuration Rack/Tower
Catalog Number 9PX5KTF5
Color Black and silver
Rating (VA/Watts) 5000/4500
 
Diagnostics Full system self test at power up
UPS Bypass MBP6K208 optional. Rear-mount 3U, 208V maintenance bypass for 5 and 6 kVA 9PX UPS models. Hardwired input. Hardwired and (2) L6-30R output
Dimensions (H x W x D, inches) 10.2 (6U) x 17.3 x 28.4
Dimensions (H x W x D, mm) 259 (6U) x 439 x 721
Weight (kg) 91
Weight (lbs) 201
Warranty 2 years
Rail Kit Included 4-post rail kit and tower pedastals included
Remote Emergency Power off (REPO) ROO/RPO: Rear deck emergency stop connectors (for remote on/off and power off)
Contents
(Ships with the following items)
9PX5K 5 kVA UPS
9PXTFMR5 120V Stepdown Transformer
Gigabit Network card (Network-M2)
4-post rail kit
User manual
Quick start guide
Tower pedestals
Intelligent Power Software Suite CD
RS-232 serial cable
USB cable
Cable gland for hardwire connection
Phillips head screw driver
Efficiency 93% with resistive load
 
Electrical Input
Connection
(1) Terminal block with L6-30P

Input Cord 6 feet (1.8 meters)
Input Voltage Range Full load: 176-276V, Derating: 100-276V
Nominal Voltage 208V default (200/208/220/230/240V)
Frequency 50/60 Hz
Frequency Range 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz
Input Power Factor >99
Input Current Distortion <5%
 
Electrical Output
Nominal Voltage 120/208V default (200/208/220/230/240V)
Output voltage regulation ±1% steady-state
Voltage THD <2% for linear loads
Output Receptacles
(18) NEMA 5-20R

(2) NEMA L6-20R

(1) NEMA L6-30R

Power Factor 0.9
Transfer Time 0 ms
Circuit Breaker (2) 20A for L6-20R; (6) 20A for 5-20R


Optional Extended Battery Module 9PXEBM180RT
Battery Description Sealed, lead-acid; maintenance free
Maximum number of extended battery modules (EBM) Add up to 4 extended battery modules (EBM)
Battery Management ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement
Battery Replacement Hot-swappable internal batteries and extended battery modules (EBMs)
Start On Battery Cold-start enabled; first cold start is always forbidden
 
Communications
User Interface Graphical display. UPS status in a single view.
LEDs 4 status-indicating LEDs
Communication Ports RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included
Communications Card Slots Gigabit Network Card (Network-M2) included
Power Management Software Eaton Intelligent Power Software Suite CD (included)
 
Environmental & Standards
RoHS Compliance Yes
Surge Protection IEEE ANSI C62.41 Cat B2
Audible Noise <45 dB at 1 meter
Operating Temperature 0 to 40°C (32°F to 104°F)
Safety markings CE / cULus / NOM
EMC Markings IEC 62040-2:2006 Cat C2 / CISPR22 Class A / FCC part 15 Class A
Storage Temperature 0 to 35°C (32°F to 95°F); without batteries: -15 to 60°C (5°F to 140°F)
Relative Humidity 0 to 95%
Altitude <1,000 meters for nominal power; 10% power derating every 1000 meters (up to 3000 meters)