12.01.2021 Views

motion-control-drives-D31-5-complete-English-2020-03-Update-2020-08

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens <strong>2020</strong><br />

Motion Control Drives<br />

SINAMICS Converters<br />

for Single-Axis Drives<br />

SINAMICS G120X infrastructure converters<br />

for HVAC/Water/Wastewater<br />

Catalog<br />

D 31.5<br />

Edition<br />

March <strong>2020</strong><br />

www.siemens.com/sinamics-g120x<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

Related catalogs<br />

Motion Control Drives D 31.1<br />

SINAMICS Inverters for Single-Axis Drives<br />

Built-In Units<br />

Industrial Controls<br />

SIRIUS Classic<br />

IC 10 AO<br />

E86060-K5531-A111-A1-7600<br />

PDF (E86060-K1010-A191-A5-7600)<br />

Motion Control Drives D 31.2<br />

SINAMICS Inverters for Single-Axis Drives<br />

Distributed Inverters<br />

E86060-K5531-A121-A1-7600<br />

SINAMICS S120 D 21.3<br />

Chassis Format Converter Units<br />

Chassis-2 Format Converter Units<br />

Cabinet Modules, Cabinet Modules-2<br />

SINAMICS S150<br />

Converter Cabinet Units<br />

E86060-K5521-A131-A7-7600<br />

Low-Voltage Power Distribution and LV 10<br />

Electrical Installation Technology<br />

SENTRON • SIVACON • ALPHA<br />

Protection, Switching, Measuring and Monitoring<br />

Devices, Switchboards and Distribution Systems<br />

PDF (E86060-K8280-A101-B1-7600)<br />

Print (E86060-K8280-A101-A6-7600)<br />

SIMATIC ST 70<br />

Products for<br />

Totally Integrated Automation<br />

PDF (E86060-K4670-A101-B7-7600)<br />

Motion Control Drives D 21.4<br />

SINAMICS S120 and SIMOTICS<br />

SIMATIC<br />

Products for<br />

Totally Integrated Automation<br />

ST 70 N<br />

E86060-K5521-A141-A1-7600<br />

PDF (E86060-K4670-A151-B1-7600)<br />

SIMOTICS S-1FG1 D 41<br />

Servo geared motors<br />

Helical, Parallel shaft, Bevel and<br />

Helical worm geared motors<br />

PDF (E86060-K5541-A101-A4-7600)<br />

SIMATIC HMI /<br />

ST 80/ST PC<br />

PC-based Automation<br />

Human Machine Interface Systems<br />

PC-based Automation<br />

PDF (E86060-K4680-A101-C7-7600)<br />

SIMOTICS GP, SD, XP, DP D 81.1<br />

Low-Voltage Motors<br />

Type series 1FP1, 1LE1, 1LE5, 1MB1, 1MB5, 1PC1<br />

Frame sizes 63 to 450<br />

Power range 0.09 to 1000 kW<br />

PDF (E86060-K5581-A111-B4-7600)<br />

Industrial Communication<br />

SIMATIC NET<br />

E86060-K6710-A101-B8-7600<br />

IK PI<br />

SIMOGEAR D 50.1<br />

Geared Motors<br />

Helical, parallel shaft, bevel, helical worm<br />

and worm geared motors<br />

E86060-K5250-A111-A6-7600<br />

Industry Mall<br />

Information and Ordering Platform<br />

on the Internet:<br />

www.siemens.com/industrymall<br />

Motion Control System PM 21<br />

SIMOTION<br />

Equipment for Production Machines<br />

E86060-K4921-A101-A4-7600<br />

Industrial Controls IC 10<br />

SIRIUS<br />

E86060-K1010-A101-B1-7600<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS Converters<br />

for Single-Axis Drives<br />

SINAMICS G120X infrastructure converters<br />

for HVAC/Water/Wastewater<br />

Catalog D 31.5 · March <strong>2020</strong><br />

Dear Customer,<br />

We are happy to present you with the new PDF version of the Catalog D 31.5 · March <strong>2020</strong>.<br />

The catalog provides a comprehensive overview of the new SINAMICS G120X converter system for HVAC, water and wastewater<br />

applications in the infrastructure sector. With an available power range from 0.75 kW to 630 kW (1 hp to 700 hp), the new series<br />

masters every challenge here.<br />

The products listed in this Catalog are also included in the Industry Mall.<br />

Please contact your local Siemens office for additional information.<br />

Up-to-date information about SINAMICS G120X is available online at<br />

www.siemens.com/sinamics-g120x<br />

You can access our Interactive Catalog and our Industry Mall on the Internet at:<br />

www.siemens.com/industrymall<br />

Your personal contact will be glad to receive your suggestions and recommendations for improvement. You can find your<br />

representative in our personal contacts database at<br />

www.siemens.com/automation-contact<br />

We hope that you will often enjoy using Catalog D 31.5 as a selection and ordering reference document and wish you every success<br />

with our products and solutions.<br />

With kind regards,<br />

Achim Peltz<br />

Vice President<br />

General Motion Control<br />

Siemens AG, Digital Industries, Motion Control<br />

siemens.com/<strong>drives</strong>


© Siemens <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS Converters for Single-Axis Drives<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Motion Control Drives<br />

System overview<br />

1<br />

SINAMICS G120X infrastructure converters<br />

2<br />

for HVAC/Water/Wastewater<br />

Catalog D 31.5 · March <strong>2020</strong><br />

Supersedes:<br />

Catalog D 31.5 · September 2019<br />

Engineering tools<br />

3<br />

Refer to the Industry Mall for current updates of<br />

this catalog:<br />

www.siemens.com/industrymall<br />

Please contact your local Siemens branch.<br />

© Siemens <strong>2020</strong><br />

Services and documentation<br />

4<br />

Appendix<br />

5<br />

Click on an Article No. in the catalog PDF to call it up in the<br />

Industry Mall and to obtain all the information.<br />

Article No.<br />

6SL3070-0AA00-0AG0<br />

6SL3072-0AA00-0AG0<br />

Or directly on the Internet, e.g.<br />

www.siemens.com/product?6SL3070-0AA00-0AG0<br />

The products and systems described in<br />

this catalog are manufactured/distributed<br />

under application of a certified quality<br />

management system in accordance with<br />

EN ISO 9001. The certificate is recognized<br />

by all IQNet countries.<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

Digital Enterprise<br />

The building blocks that ensure<br />

everything works together<br />

perfectly in the digital enterprise<br />

Digitalization is already changing all areas of life and existing<br />

business models. It is placing greater pressure on industry<br />

while at the same time creating new business opportunities.<br />

Today, thanks to scalable solutions from Siemens, companies<br />

can already become a digital enterprise and ensure their<br />

competitiveness.<br />

Industry faces tremendous challenges<br />

Reduce<br />

time-to-market<br />

Boost<br />

flexibility<br />

Improve<br />

quality<br />

Boost<br />

efficiency<br />

Increase<br />

security<br />

Today manufacturers<br />

have to bring products to<br />

market at an ever-increasing<br />

pace despite the<br />

growing complexity of<br />

these products. In the<br />

past, a major manufacturer<br />

would push aside a<br />

small one, but now it is a<br />

fast manufacturer that<br />

overtakes a slow one.<br />

Consumers want customized<br />

products, but at<br />

a price they would pay<br />

for a mass-produced<br />

item. That only works<br />

if production is more<br />

flexible than ever<br />

before.<br />

To ensure a high level of<br />

quality while meeting<br />

legal requirements,<br />

companies have to<br />

establish closed quality<br />

loops and enable the<br />

traceability of products.<br />

Today the product itself<br />

needs to be sustainable<br />

and environmentally<br />

friendly, while energy<br />

efficiency in production<br />

has become a competitive<br />

advantage.<br />

Increasing networking<br />

escalates the threat to<br />

production facilities<br />

of cyberattacks. Today<br />

more than ever, companies<br />

need suitable<br />

security measures.<br />

2 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

The digital enterprise has already<br />

become a reality<br />

To fully benefit from all the advantages of<br />

digitalization, companies first have to<br />

achieve <strong>complete</strong> consistency of their data.<br />

Fully digitally integrated business processes,<br />

including those of suppliers, can help to<br />

create a digital representation of the entire<br />

value chain. This requires<br />

• the integration of industrial software<br />

and automation,<br />

• expansion of the communication networks,<br />

• security in automation,<br />

• and the use of business-specific<br />

industrial services.<br />

MindSphere<br />

The cloud-based open IoT operating<br />

system from Siemens<br />

With MindSphere, Siemens offers a costeffective<br />

and scalable cloud platform as a<br />

service (PaaS) for the development of applications.<br />

The platform, designed as an open<br />

operating system for the Internet of Things,<br />

makes it possible to improve the efficiency<br />

of plants by collecting and analyzing large<br />

volumes of production data.<br />

Totally Integrated Automation (TIA)<br />

Where digitalization becomes reality<br />

Totally Integrated Automation (TIA) ensures<br />

the seamless transition from the virtual to<br />

the real world. It already encompasses all<br />

the necessary conditions for transforming<br />

the benefits of digitalization into true added<br />

value. The data that will form the digital<br />

twin for actual production is generated from<br />

a common base.<br />

Digital Plant<br />

Learn more about the<br />

digital enterprise for the<br />

process industry<br />

www.siemens.com/<br />

digitalplant<br />

Digital Enterprise Suite<br />

Learn more about the<br />

digital enterprise for the<br />

discrete industry<br />

www.siemens.com/<br />

digital-enterprise-suite<br />

Siemens D 31.5 · March <strong>2020</strong><br />

3


© Siemens <strong>2020</strong><br />

Integrated Drive Systems<br />

Faster on the market and in the black with Integrated Drive Systems<br />

Integrated Drive Systems are Siemens’ trendsetting answer to the high<br />

degree of complexity that characterizes drive and automation technology<br />

today. The world’s only true one-stop solution for entire drive systems is<br />

characterized in particular by its threefold integration: Horizontal, vertical,<br />

and lifecycle integration ensure that every drive system component fits<br />

seamlessly into the whole system, into any automation environment, and<br />

even into the entire lifecycle of a plant.<br />

The outcome is an optimal workflow – from engineering all the way to<br />

service that entails more productivity, increased efficiency, and better<br />

availability. That’s how Integrated Drive Systems reduce time to market<br />

and time to profit.<br />

Horizontal integration<br />

Integrated drive portfolio: The core elements of a fully integrated drive<br />

portfolio are frequency converters, motors, couplings, and gear units.<br />

At Siemens, they‘re all available from a single source. Perfectly integrated,<br />

perfectly interacting. For all power and performance classes. As standard<br />

solutions or fully customized. No other player in the market can offer a<br />

comparable portfolio. Moreover, all Siemens drive components are<br />

perfectly matched, so they are optimally interacting.<br />

You can boost the avail ability<br />

of your application or plant<br />

to up to<br />

99 % *<br />

*e.g., conveyor application<br />

Vertical integration<br />

Thanks to vertical integration, the <strong>complete</strong> drive train is<br />

seamlessly integrated in the entire automation environment –<br />

an important prerequisite for production with maximum<br />

value added. Integrated Drive Systems are part of Totally<br />

Integrated Automation (TIA), which means that they<br />

are perfectly embedded into the system architecture<br />

of the entire industrial production process. This<br />

enables optimal processes through maximum<br />

communication and <strong>control</strong>.<br />

With TIA Portal you can<br />

cut your engineering time<br />

by up to<br />

30 %<br />

Lifecycle integration<br />

Lifecycle integration adds the factor of time: Software and service<br />

are available for the entire lifecycle of an Integrated Drive System.<br />

That way, important optimization potential for maximum<br />

productivity, increased efficiency, and highest availability<br />

can be leveraged throughout the system’s lifecycle –<br />

from planning, design, and engineering to operation,<br />

maintenance, and all the way even to<br />

modernization.<br />

With Integrated Drive Systems, assets<br />

become important success factors. They<br />

ensure shorter time to market, maximum<br />

productivity and efficiency in operation,<br />

and shorter time to profit.<br />

With Integrated Drive<br />

Systems you can reduce<br />

your main tenance costs<br />

by up to<br />

15 %<br />

www.siemens.com/ids<br />

4 Siemens D 31.5 · March <strong>2020</strong>


System overview<br />

© Siemens <strong>2020</strong><br />

1<br />

1/2 The SINAMICS converter family<br />

1/6 Drive selection<br />

1/7 SIMOTICS motors<br />

1/8 SIMOTICS low-voltage motors<br />

for line and converter operation<br />

1/9 Energy efficiency classes<br />

in accordance with EN 50598<br />

1/12 SINAMICS G120X infrastructure<br />

converters for HVAC/Water/Wastewater<br />

1/14 SINAMICS G120X Starter Kits<br />

Further information about SINAMICS and<br />

SIMOTICS can be found on the Internet at<br />

www.siemens.com/sinamics<br />

www.siemens.com/simotics<br />

Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

System overview<br />

1<br />

The SINAMICS converter family<br />

■ Overview<br />

Integration in automation<br />

Management level<br />

Office environment: SIMATIC IT / COMOS...<br />

Process <strong>control</strong> level<br />

Control center / <strong>control</strong> system:<br />

SIMATIC PCS 7 / WINCC<br />

Control level<br />

Automation systems / HMI:<br />

SIMATIC / SIMOTION / SINUMERIK<br />

Fieldbus<br />

SINAMICS V<br />

SINAMICS G<br />

SINAMICS V<br />

SINAMICS G<br />

SINAMICS S<br />

SINAMICS V<br />

SINAMICS G<br />

SINAMICS S<br />

SINAMICS S<br />

pumping<br />

ventilating<br />

compressing moving processing machining<br />

G_D011_EN_0<strong>03</strong>37d<br />

Totally Integrated Automation and communication<br />

SINAMICS is an integral component of the Siemens "Totally<br />

Integrated Automation" concept. Integrated SINAMICS systems<br />

covering configuration, data storage, and communication at<br />

automation level ensure low-maintenance solutions with the<br />

SIMATIC, SIMOTION and SINUMERIK <strong>control</strong> systems.<br />

Depending on the application, the appropriate variable<br />

frequency <strong>drives</strong> can be selected and incorporated in the<br />

automation concept. With this in mind, the <strong>drives</strong> are clearly<br />

subdivided into their different applications. A wide range of<br />

communication options (depending on the drive type) are<br />

available for establishing a communication link to the automation<br />

system:<br />

• PROFINET<br />

• PROFIBUS<br />

• EtherNet/IP<br />

• Modbus TCP<br />

• Modbus RTU<br />

• AS-Interface<br />

• BACnet MS/TP<br />

Applications<br />

SINAMICS is the comprehensive converter family from Siemens<br />

designed for machine and plant engineering applications.<br />

SINAMICS offers solutions for all drive tasks:<br />

• Simple pump and fan applications in the process industry<br />

• Demanding single <strong>drives</strong> in centrifuges, presses, extruders,<br />

elevators, as well as conveyor and transport systems<br />

• Drive line-ups in textile, plastic film, and paper machines as<br />

well as in rolling mill plants<br />

• Highly dynamic servo <strong>drives</strong> for machine tools, as well as<br />

packaging and printing machines<br />

1/2 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

System overview<br />

■ Overview<br />

SINAMICS as part of the Siemens modular automation system<br />

The SINAMICS converter family<br />

1<br />

SIMOTION<br />

SINUMERIK<br />

SIMATIC<br />

SINAMICS<br />

SIMOGEAR<br />

SIMOTICS<br />

G_D011_XX_00515b<br />

Innovative, energy-efficient and reliable drive systems and<br />

applications as well as services for the entire drive train<br />

The solutions for drive technology place great emphasis on the<br />

highest productivity, energy efficiency and reliability for all<br />

torque ranges, performance and voltage classes.<br />

Siemens offers not only the right innovative variable frequency<br />

drive for every drive application, but also a wide range of<br />

energy-efficient low-voltage motors, geared motors, explosionprotected<br />

motors and high-voltage motors for combination with<br />

SINAMICS.<br />

Furthermore, Siemens supports its customers with global<br />

pre-sales and after-sales services, with over 295 service points<br />

in 130 countries – and with special services e.g. application<br />

consulting or <strong>motion</strong> <strong>control</strong> solutions.<br />

Energy efficiency<br />

Energy management process<br />

Efficient energy management consultancy identifies the energy<br />

flows, determines the potential for making savings and implements<br />

them with focused activities.<br />

Almost two thirds of the industrial power requirement is from<br />

electric motors. This makes it all the more important to use drive<br />

technology permitting energy consumption to be reduced<br />

effectively even in the configuration phase, and consequently to<br />

optimize plant availability and process stability. With SINAMICS,<br />

Siemens offers powerful energy efficient solutions which,<br />

depending on the application, enable a significant reduction<br />

in electricity costs.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

1/3


© Siemens <strong>2020</strong><br />

System overview<br />

1<br />

The SINAMICS converter family<br />

■ Overview<br />

Up to 70 % potential for savings using variable-speed operation<br />

SINAMICS enables great potential for savings to be realized by<br />

<strong>control</strong>ling the motor speed. In particular, huge potential savings<br />

can be recovered from pumps, fans and compressors which are<br />

operated with mechanical throttle and valves. Here, changing to<br />

variable-speed <strong>drives</strong> brings enormous economic advantages.<br />

In contrast to mechanical <strong>control</strong> systems, the power consumption<br />

at partial load operation is always immediately adjusted to<br />

the demand at that time. So energy is no longer wasted, permitting<br />

savings of up to 60 % – in exceptional cases even up to<br />

70 %. Variable-speed <strong>drives</strong> also offer clear advantages over<br />

mechanical <strong>control</strong> systems when it comes to maintenance and<br />

repair. Current spikes when starting up the motor and strong<br />

torque surges become things of the past – and the same goes<br />

for pressure waves in pipelines, cavitation or vibrations which<br />

cause sustainable damage to the plant. Smooth starting and<br />

ramp-down relieve the load on the mechanical system, ensuring<br />

a significantly longer service life of the entire drive train.<br />

Regenerative feedback of braking energy<br />

In conventional drive systems, the energy produced during<br />

braking is converted to heat using braking resistors. Energy<br />

produced during braking is efficiently recovered to the supply<br />

system by versions of SINAMICS G and SINAMICS S <strong>drives</strong> with<br />

regenerative feedback capability and these devices do not<br />

therefore need a braking resistor. This permits up to 60 % of the<br />

energy requirement to be saved, e.g. in lifting applications.<br />

Energy which can be reused at other locations on a machine.<br />

Furthermore, this reduced power loss simplifies the cooling of<br />

the system, enabling a more compact design.<br />

Energy transparency in all configuration phases<br />

Early on, in the configuration phase, the SIZER for Siemens<br />

Drives engineering tool provides information on the specific<br />

energy requirement. The energy consumption across the entire<br />

drive train is visualized and compared with different plant<br />

concepts.<br />

SINAMICS in combination with energy-saving motors<br />

Engineering integration stretches beyond the SINAMICS<br />

converter family to higher-level automation systems, and to a<br />

broad spectrum of energy-efficient motors with a wide range of<br />

performance classes, which, compared to previous motors, are<br />

able to demonstrate up to 10 % greater efficiency.<br />

Variants<br />

Depending on the application, the SINAMICS converter family offers the ideal variant for any drive task.<br />

Performance<br />

SINAMICS V<br />

SINAMICS G<br />

SINAMICS S<br />

Price<br />

SINAMICS V <strong>drives</strong> focus on<br />

the essentials both in terms of hardware<br />

and functionality.<br />

This results in a high degree of ruggedness<br />

combined with lower investment costs.<br />

SINAMICS G <strong>drives</strong> function perfectly for low<br />

and medium demands on the dynamic<br />

response of the <strong>control</strong> system.<br />

SINAMICS S <strong>drives</strong> are predestined<br />

for demanding single - and multi-axis<br />

applications in machine and plant engineering<br />

as well as for numerous <strong>motion</strong> <strong>control</strong> tasks.<br />

G_D011_EN_00449b<br />

1/4 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

System overview<br />

■ Overview<br />

Platform concept<br />

All SINAMICS variants are based on a platform concept. Joint<br />

hardware and software components, as well as standardized<br />

tools for dimensioning, configuration, and commissioning tasks<br />

ensure high-level integration across all components. SINAMICS<br />

handles a wide variety of drive tasks with no system gaps. The<br />

different SINAMICS variants can be easily combined with each<br />

other.<br />

Quality management according to EN ISO 9001<br />

SINAMICS conforms to the most exacting quality requirements.<br />

Comprehensive quality assurance measures in all development<br />

and production processes ensure a consistently high level of<br />

quality.<br />

Of course, our quality management system is certified by an<br />

independent authority in accordance with EN ISO 9001.<br />

The SINAMICS converter family<br />

IDS – Integration at its very best<br />

The Siemens Integrated Drive Systems (IDS) solution offers perfectly<br />

matched drive components with which you can meet your<br />

requirements. The drive components reveal their true strengths<br />

as an Integrated Drive System over the full range from engineering<br />

and commissioning through to operation: Integrated system<br />

configuration is performed using the Drive Technology Configurator:<br />

Just select a motor and a converter and design them with<br />

the SIZER for Siemens Drives engineering tool. The STARTER<br />

and SINAMICS Startdrive commissioning tools integrate the motor<br />

data and at the same time simplify efficient commissioning.<br />

Integrated Drive Systems are incorporated in the TIA Portal – this<br />

simplifies engineering, commissioning and diagnostics.<br />

1<br />

Low voltage<br />

Direct<br />

voltage<br />

Medium<br />

voltage<br />

Standard performance<br />

frequency converters<br />

Distributed<br />

frequency<br />

converters<br />

Industry-specific frequency<br />

converters<br />

Servo <strong>drives</strong><br />

High performance<br />

frequency converters<br />

DC<br />

converters<br />

Converters for<br />

applications<br />

with high<br />

outputs<br />

SINAMICS<br />

V20<br />

G120C<br />

G120<br />

SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS<br />

G130<br />

G150<br />

G110D<br />

G120D<br />

G110M<br />

SIMATIC<br />

ET 200pro FC-2<br />

G120X G180 V90 S110 S210 S120<br />

S120M<br />

S150 DCM<br />

DCP *<br />

GH150<br />

GH180<br />

GM150<br />

SM150<br />

GL150<br />

SL150<br />

SM120CM<br />

0.12 kW to<br />

250 kW<br />

75 kW to<br />

2700 kW<br />

Pumps, fans, Pumps,<br />

compressors, fans,<br />

conveyor compressors,<br />

belts, mixers, conveyor<br />

mills, spinning belts, mixers,<br />

machines, mills,<br />

textile extruders<br />

machines,<br />

refrigerated<br />

display<br />

counters,<br />

fitness<br />

equipment,<br />

ventilation<br />

systems,<br />

single-axis<br />

positioning<br />

applications in<br />

machine and<br />

plant<br />

engineering<br />

0.37 kW to<br />

7.5 kW<br />

Conveyor<br />

technology,<br />

single-axis<br />

positioning<br />

applications<br />

(G120D)<br />

0.75 kW to<br />

630 kW<br />

Pumps,<br />

fans,<br />

compressors,<br />

building<br />

management<br />

systems,<br />

process<br />

industry,<br />

HVAC,<br />

water/waste<br />

water<br />

industries<br />

2.2 kW to<br />

6600 kW<br />

Pumps,<br />

fans,<br />

compressors,<br />

conveyor<br />

belts,<br />

extruders,<br />

mixers, mills,<br />

kneaders,<br />

centrifuges,<br />

separators<br />

0.05 kW to<br />

7 kW<br />

Handling<br />

machines,<br />

packaging<br />

machines,<br />

automatic<br />

assembly<br />

machines,<br />

metal forming<br />

machines,<br />

printing<br />

machines,<br />

winding and<br />

unwinding<br />

units<br />

0.55 kW to<br />

132 kW<br />

Single-axis<br />

positioning<br />

applications in<br />

machine and<br />

plant<br />

engineering<br />

0.05 kW to<br />

7 kW<br />

Packaging<br />

machines,<br />

handling<br />

equipment,<br />

feed and<br />

withdrawal<br />

devices,<br />

stacking units,<br />

automatic<br />

assembly<br />

machines,<br />

laboratory<br />

automation,<br />

wood, glass<br />

and ceramics<br />

industry,<br />

digital printing<br />

machines<br />

0.55 kW to<br />

5700 kW<br />

Production<br />

machines<br />

(packaging,<br />

textile and<br />

printing<br />

machines,<br />

paper<br />

machines,<br />

plastic<br />

processing<br />

machines),<br />

machine<br />

tools, plants,<br />

process lines<br />

and rolling<br />

mills, marine<br />

<strong>drives</strong>, test<br />

bays<br />

75 kW to<br />

1200 kW<br />

Test bays,<br />

cross cutters,<br />

centrifuges<br />

6 kW to<br />

30 MW<br />

Rolling mill<br />

<strong>drives</strong>,<br />

wire-drawing<br />

machines,<br />

extruders and<br />

kneaders,<br />

cableways<br />

and lifts,<br />

test bay <strong>drives</strong><br />

* DC/DC<br />

<strong>control</strong>lers<br />

0.15 MW to<br />

85 MW<br />

Pumps,<br />

fans,<br />

compressors,<br />

mixers,<br />

extruders,<br />

mills,<br />

crushers,<br />

rolling mills,<br />

conveyor<br />

technology,<br />

excavators,<br />

test bays,<br />

marine <strong>drives</strong>,<br />

blast furnace<br />

fans, retrofit<br />

Catalog<br />

D 31.1<br />

Catalog Catalog Catalog Catalog<br />

D 11 D 31.2 D 31.5 D 18.1<br />

Catalog<br />

D 33<br />

Catalog Catalog<br />

D 31.1 D 32<br />

Catalogs<br />

D 21.3, D 21.4<br />

NC 62<br />

Catalog<br />

D 21.3<br />

Catalog<br />

D 23.1<br />

* Industry Mall<br />

Catalogs<br />

D 15.1, D 12<br />

Engineering tools (e.g. Drive Technology Configurator, SIZER for Siemens Drives, STARTER and SINAMICS Startdrive)<br />

G_D011_EN_00450o<br />

Siemens D 31.5 · March <strong>2020</strong><br />

1/5


© Siemens <strong>2020</strong><br />

System overview<br />

1<br />

Drive selection<br />

■ Overview<br />

SINAMICS selection guide – typical applications<br />

Use<br />

Requirements for torque accuracy/speed accuracy/position accuracy/coordination of axes/functionality<br />

Continuous <strong>motion</strong><br />

Non-continuous <strong>motion</strong><br />

Basic Medium High Basic Medium High<br />

Pumping,<br />

ventilating,<br />

compressing<br />

Centrifugal pumps<br />

Radial / axial fans<br />

Compressors<br />

V20<br />

G120C<br />

G120X<br />

Centrifugal pumps<br />

Radial / axial fans<br />

Compressors<br />

Eccentric screw<br />

pumps<br />

Hydraulic pumps<br />

Metering pumps<br />

Hydraulic pumps<br />

Metering pumps<br />

G120X<br />

S120 G120 S110 S120<br />

G180 1) G130/G150<br />

Descaling pumps<br />

Hydraulic pumps<br />

Moving<br />

Processing<br />

Machining<br />

Conveyor belts<br />

Roller conveyors<br />

Chain conveyors<br />

V20<br />

G110D<br />

G110M<br />

G120C<br />

ET 200pro FC-2 2)<br />

Mills<br />

Mixers<br />

Kneaders<br />

Crushers<br />

Agitators<br />

Centrifuges<br />

V20<br />

G120C<br />

Main <strong>drives</strong> for<br />

• Turning<br />

• Milling<br />

• Drilling<br />

S110<br />

Using the SINAMICS selection guide<br />

Conveyor belts<br />

Roller conveyors<br />

Chain conveyors<br />

Lifting/<br />

lowering devices<br />

Elevators<br />

Escalators/<br />

moving walkways<br />

Indoor cranes<br />

Marine <strong>drives</strong><br />

Cable railways<br />

G120<br />

G120D<br />

G130/G150<br />

G180 1)<br />

Mills<br />

Mixers<br />

Kneaders<br />

Crushers<br />

Agitators<br />

Centrifuges<br />

Extruders<br />

Rotary furnaces<br />

G120<br />

G130/G150<br />

G180 1)<br />

Main <strong>drives</strong> for<br />

• Drilling<br />

• Sawing<br />

S110<br />

S120<br />

Elevators<br />

Container cranes<br />

Mining hoists<br />

Excavators for<br />

open-cast mining<br />

Test bays<br />

S120<br />

S150<br />

DCM<br />

Extruders<br />

Winders/unwinders<br />

Lead/follower <strong>drives</strong><br />

Calenders<br />

Main press <strong>drives</strong><br />

Printing machines<br />

S120<br />

S150<br />

DCM<br />

Main <strong>drives</strong> for<br />

• Turning<br />

• Milling<br />

• Drilling<br />

• Gear cutting<br />

•Grinding<br />

The varying range of demands on modern variable frequency<br />

<strong>drives</strong> requires a large number of different types. Selecting<br />

the optimum drive has become a significantly more complex<br />

process. The application matrix shown simplifies this selection<br />

process considerably, by suggesting the ideal SINAMICS drive<br />

for examples of typical applications and requirements.<br />

■ More information<br />

Further information about SINAMICS is available on the Internet at<br />

www.siemens.com/sinamics<br />

Practical application examples and descriptions are available on the Internet at<br />

www.siemens.com/sinamics-applications<br />

Acceleration<br />

conveyors<br />

Storage and retrieval<br />

machines<br />

V90<br />

G120<br />

G120D<br />

Tubular bagging<br />

machines<br />

Single-axis <strong>motion</strong><br />

<strong>control</strong><br />

such as<br />

• Position profiles<br />

• Path profiles<br />

V90<br />

G120<br />

Axis <strong>drives</strong> for<br />

• Turning<br />

• Milling<br />

• Drilling<br />

Acceleration<br />

conveyors<br />

Storage and retrieval<br />

machines<br />

Cross cutters<br />

Reel changers<br />

S110<br />

S210<br />

DCM<br />

Tubular bagging<br />

machines<br />

Single-axis <strong>motion</strong><br />

<strong>control</strong><br />

such as<br />

• Position profiles<br />

• Path profiles<br />

S110<br />

S210<br />

S120 S110 S110<br />

S120<br />

Axis <strong>drives</strong> for<br />

• Drilling<br />

• Sawing<br />

Storage and retrieval<br />

machines<br />

Robotics<br />

Pick & place<br />

Rotary indexing tables<br />

Cross cutters<br />

Roll feeds<br />

Engagers/<br />

disengagers<br />

S120<br />

S210<br />

DCM<br />

Servo presses<br />

Rolling mill <strong>drives</strong><br />

Multi-axis <strong>motion</strong><br />

<strong>control</strong><br />

such as<br />

• Multi-axis positioning<br />

•Cams<br />

• Interpolations<br />

S120<br />

S210<br />

DCM<br />

Axis <strong>drives</strong> for<br />

• Turning<br />

• Milling<br />

• Drilling<br />

• Lasering<br />

• Gear cutting<br />

•Grinding<br />

• Nibbling and<br />

punching<br />

S120<br />

• The application type is selected from the vertical column<br />

- Pumping, ventilating, compressing<br />

-Moving<br />

- Processing<br />

- Machining<br />

• The quality of the <strong>motion</strong> type is selected from the horizontal row<br />

-Basic<br />

-Medium<br />

-High<br />

1) Industry-specific converters.<br />

2) Information on the SIMATIC ET 200pro FC-2 frequency converter is<br />

available in Catalog D 31.2 and at www.siemens.com/et200pro-fc<br />

1/6 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

System overview<br />

■ Overview<br />

SIMOTICS motors<br />

1<br />

SIMOTICS<br />

Low-voltage motors for line and converter operation<br />

General Purpose<br />

SIMOTICS GP<br />

Severe Duty<br />

SIMOTICS SD<br />

Explosion-proof<br />

SIMOTICS XP<br />

Definite Purpose<br />

SIMOTICS DP<br />

Flexible Duty<br />

SIMOTICS FD<br />

Transnorm<br />

SIMOTICS TN<br />

High Torque<br />

SIMOTICS HT<br />

DC motors<br />

Direct Current SIMOTICS DC<br />

High-voltage motors<br />

High Voltage SIMOTICS HV<br />

Motors for <strong>motion</strong> <strong>control</strong><br />

SIMOTICS S servomotors SIMOTICS M main motors SIMOTICS L linear motors SIMOTICS T torque motors<br />

Servomotors Servo geared motors<br />

G_D011_EN_00491<br />

SIMOTICS stands for<br />

• 150 years of experience in building electric motors<br />

• The most comprehensive range of motors worldwide<br />

• Optimum solutions in all industries, regions and power/<br />

performance classes<br />

• Innovative motor technologies of the highest quality and<br />

reliability<br />

• Highest dynamic performance, precision and efficiency<br />

together with the optimum degree of compactness<br />

• Our motors can be integrated into the drive train as part of the<br />

overall system<br />

• A global network of skill sets and worldwide service around<br />

the clock<br />

A clearly structured portfolio<br />

The entire SIMOTICS product portfolio is transparently organized<br />

according to application-specific criteria in order to help<br />

users select the optimum motor for their application.<br />

The product range extends from standard motors for pumps,<br />

fans and compressors to highly dynamic, precise <strong>motion</strong> <strong>control</strong><br />

motors for positioning tasks and <strong>motion</strong> <strong>control</strong> in handling applications,<br />

as well as production machinery and machine tools,<br />

to DC motors and powerful high-voltage motors. Whatever it is<br />

that you want to move – we can supply the right motor for the<br />

task.<br />

www.siemens.com/simotics<br />

An outstanding performance for any job<br />

A key characteristic of all SIMOTICS motors is their quality. They<br />

are robust, reliable, dynamic and precise to assure the requisite<br />

performance level for any process and deliver exactly the capabilities<br />

demanded by the application in hand. Thanks to their<br />

compact design, they can be integrated as space-saving units<br />

into installations. Furthermore, their impressive energy efficiency<br />

makes them effective as a means of reducing operating costs<br />

and protecting the environment.<br />

A dense network of skill sets and servicing expertise<br />

around the world<br />

SIMOTICS offers not only a wealth of sound experience gleaned<br />

from a development history which stretches back over around<br />

150 years, but also the know-how of hundreds of engineers. This<br />

knowledge and our worldwide presence form the basis for a<br />

unique proximity to industries which feeds through in tangible<br />

terms to the specific motor configuration which is tailored to suit<br />

your application.<br />

Our specialists are available to answer all your queries regarding<br />

any aspect of motor technology. At any time – wherever you<br />

are in the world. When you choose SIMOTICS, therefore, you<br />

reap the benefits of a global service network which is continuously<br />

accessible, thereby helping to optimize response times<br />

and minimize downtimes.<br />

Perfection of the <strong>complete</strong> drive train<br />

SIMOTICS is perfectly coordinated with other Siemens product<br />

families. In combination with the SINAMICS integrated converter<br />

family and the SIRIUS <strong>complete</strong> portfolio of industrial <strong>control</strong>s,<br />

SIMOTICS fits seamlessly as part of the <strong>complete</strong> drive train<br />

into automation solutions which are based on the SIMATIC,<br />

SIMOTION and SINUMERIK <strong>control</strong> systems.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

1/7


© Siemens <strong>2020</strong><br />

System overview<br />

1<br />

SIMOTICS low-voltage motors for line and converter operation<br />

■ Overview<br />

Low-voltage motors for line and converter operation<br />

General Purpose<br />

SIMOTICS GP<br />

Severe Duty<br />

SIMOTICS SD<br />

Explosion Proof<br />

SIMOTICS XP<br />

Definite Purpose<br />

SIMOTICS DP<br />

Transnorm<br />

SIMOTICS TN<br />

Flexible Duty<br />

SIMOTICS FD<br />

High Torque<br />

SIMOTICS HT<br />

IEC:<br />

0.09 … 45 kW<br />

Reluctance:<br />

0.55 … 52 kW<br />

NEMA:<br />

1 … 200 hp<br />

IEC:<br />

0.09 … 200 kW<br />

Reluctance:<br />

0.55 … 78 kW<br />

NEMA:<br />

1 … 400 hp<br />

IEC:<br />

0.09 … 460 kW<br />

IEC:<br />

0.37 … 200 kW<br />

200 ... 3500 kW<br />

200 ... 1800 kW 150 ... 2100 kW<br />

NEMA:<br />

1 … 300 hp<br />

NEMA:<br />

1 … 200 hp<br />

IEC:<br />

0.6 … 294 Nm<br />

Reluctance:<br />

3.4 … 191 Nm<br />

NEMA:<br />

1.5 … 883 lb-ft<br />

IEC:<br />

1 … 1202 Nm<br />

Reluctance:<br />

2.3 … 286 Nm<br />

NEMA:<br />

1.5 … 1483 lb-ft<br />

IEC:<br />

1.2 … 4043 Nm<br />

NEMA:<br />

1.5 … 1187 lb-ft<br />

IEC:<br />

2.5 … 1546 Nm<br />

NEMA:<br />

1.5 … 1104 lb-ft<br />

642 … 2<strong>08</strong>64 Nm 610 … 14600 Nm 6000 … 42000 Nm<br />

IEC:<br />

750 … 3000 rpm<br />

(at 50 Hz)<br />

Reluctance:<br />

1500/1800/2610 rpm<br />

NEMA:<br />

900 … 3600 rpm<br />

(at 60 Hz)<br />

IEC:<br />

750 … 3000 rpm<br />

(at 50 Hz)<br />

Reluctance:<br />

1500/1800/2610/<br />

3000/3600 rpm<br />

NEMA:<br />

900 … 3600 rpm<br />

(at 60 Hz)<br />

IEC:<br />

750 … 3000 rpm<br />

(at 50 Hz)<br />

NEMA:<br />

900 … 3600 rpm<br />

(at 60 Hz)<br />

IEC:<br />

750 … 3000 rpm<br />

(at 50 Hz)<br />

NEMA:<br />

900 … 3600 rpm<br />

(at 60 Hz)<br />

IEC:<br />

750 … 3000 rpm<br />

(at 50 Hz)<br />

IEC:<br />

750 … 3000 rpm<br />

(at 50 Hz)<br />

IEC:<br />

200 … 800 rpm<br />

(at 50 Hz)<br />

Pumps, fans and<br />

compressors with<br />

especially low<br />

weight requirements<br />

Pumps, fans,<br />

compressors,<br />

mixers, mills,<br />

extruders and<br />

rollers with special<br />

demands in terms<br />

of ruggedness,<br />

particularly in the<br />

chemical and<br />

petrochemical<br />

industries<br />

General industrial<br />

applications with<br />

special requirements<br />

regarding<br />

explosion protection<br />

for use in Zones 1,<br />

2, 21, and 22 such<br />

as in the process<br />

industry<br />

Ships, work and<br />

transport roller<br />

tables, tunnels,<br />

multi-story car<br />

parks, shopping<br />

malls, dockside<br />

cranes, container<br />

terminals as well as<br />

motors customized<br />

for special<br />

applications<br />

Pumps, fans,<br />

compressors,<br />

conveyor belts,<br />

mixers, extruders in<br />

the chem. and<br />

petrochem. industry,<br />

paper-making<br />

machines, mining,<br />

cement, steel<br />

industry, and marine<br />

applications<br />

including propulsion<br />

Pumps, fans,<br />

compressors,<br />

conveyor belts,<br />

centrifuges,<br />

extruders, winders,<br />

hoisting gear in<br />

cranes, presses,<br />

paper machines,<br />

rolling mills, marine<br />

applications<br />

including propulsion<br />

High-torque<br />

gearless motors for<br />

paper-making<br />

machines,<br />

low-speed pumps,<br />

mills, steel shears,<br />

bow thrusters,<br />

winches or main<br />

<strong>drives</strong> on ships<br />

IEC: D 81.1<br />

NEMA: D 81.2<br />

IEC: D 81.1<br />

NEMA: D 81.2<br />

SIMOTICS GP and SIMOTICS SD<br />

SIMOTICS GP General Purpose motors with an aluminum housing<br />

are suitable for a wide range of standard drive tasks in industrial<br />

environments. SIMOTICS SD Severe Duty motors with a<br />

cast-iron housing are extremely rugged and are therefore the<br />

first choice for applications in harsh environmental conditions.<br />

SIMOTICS GP and SIMOTICS SD are fundamentally optimized<br />

for line operation. In addition, two converter-optimized motor<br />

lines are available for variable-speed converter-fed operation.<br />

• Induction technology (VSD10 line)<br />

The VSD10 line converter motors are designed exclusively for<br />

use on converters and are specially optimized for SINAMICS<br />

frequency converters. In terms of economy, efficiency and<br />

reliability, they are perfectly matched to SINAMICS G120<br />

standard converters over the <strong>complete</strong> life cycle.<br />

1/8 Siemens D 31.5 · March <strong>2020</strong><br />

IEC: D 81.1, D 83.1<br />

NEMA: D 81.2<br />

IEC: D 81.1<br />

NEMA: D 81.2<br />

D 81.1, D 84.1 D 81.8 D 86.2<br />

G_D011_EN_00516b<br />

• Synchronous reluctance technology (VSD4000 line)<br />

VSD4000 line reluctance motors are designed exclusively for<br />

use on converters and are specially optimized for<br />

SINAMICS G120. Compared to systems with induction<br />

motors, synchronous reluctance technology is characterized<br />

by particularly high efficiency levels, especially in the partial<br />

load range, and by high dynamics. The vector <strong>control</strong> of the<br />

frequency converter ensures optimal operating characteristics.<br />

More information on the reluctance drive system is<br />

available at<br />

www.siemens.com/reluctance-drive-system<br />

SIMOTICS XP<br />

Our rugged SIMOTICS XP explosion-proof motors are exceptionally<br />

durable, even in the harshest conditions, and absolutely<br />

fail-safe - in both line and converter operation.<br />

SIMOTICS XP motors meet all requirements with maximum<br />

safety and maximum efficiency.<br />

Note: Suitable for use with SINAMICS G120X only when installed<br />

in a safe area. Suitable for motors in an explosion-proof enclosure<br />

design.


© Siemens <strong>2020</strong><br />

System overview<br />

■ Overview<br />

Step by step to more efficiency<br />

One of the core objectives of the European Union is a sustainable<br />

power industry. In industrial plants today, around 70 % of<br />

the power demand is from electrically driven systems. This high<br />

percentage contains huge potential for saving energy in electrical<br />

<strong>drives</strong>. For that reason, the European Union introduced<br />

minimum requirements for the energy efficiency of electric<br />

motors in the form of a statutory motor regulation as early as<br />

2011.<br />

However, measures aimed solely at the motor are not enough to<br />

achieve the mandatory energy-saving targets. The European<br />

legislation fills this gap with the standard series EN 50598 and<br />

extends the focus from individual drive components to entire<br />

drive systems, even enabling consideration of specific use<br />

cases.<br />

The European standard series EN 50598 defines the ecodesign<br />

requirements for drive systems in the low-voltage range with an<br />

electrically driven machine. It consists of definitions for energy<br />

efficiency (parts 1 and 2) and an ecobalance calculation<br />

(part 3).<br />

To take account of the different use cases, consideration of eight<br />

application-relevant operating points has been introduced as<br />

mandatory for the first time. Determination of loss values at these<br />

eight points and definition of efficiency classes are laid down by<br />

the standard in a uniform way. This enables data relevant to<br />

operation, such as application-specific load profiles, to now be<br />

taken into account more easily in the energy efficiency analysis.<br />

The standard is especially important for variable-speed <strong>drives</strong> of<br />

the following types:<br />

• for AC/AC converters without energy recovery functionality<br />

• for motors with integrated converters<br />

• for supply voltages of 100 V to 1000 V<br />

• for power ratings of 0.12 kW to 1000 kW<br />

To cover all applications of driven machines, the new standard<br />

defines operating points in full-load and partial-load operation,<br />

at which the losses of the motor and drive systems have to be<br />

determined. Based on the loss data at the operating points in<br />

partial-load operation, variable-speed <strong>drives</strong> can be explicitly<br />

considered in more detail. This makes their advantages<br />

especially clear.<br />

Energy efficiency classes in accordance with EN 50598<br />

Centrifugal pumps, fans<br />

Hoisting gear, extruders,<br />

conveyor belts<br />

Winders, coilers<br />

Relative<br />

torque<br />

Relative<br />

torque<br />

Relative<br />

torque<br />

100<br />

%<br />

50<br />

25<br />

100<br />

%<br />

50<br />

25<br />

100<br />

%<br />

50<br />

25<br />

Load torque M ~ n 2<br />

50<br />

Relative speed<br />

50<br />

Relative speed<br />

Duty cycles for different driven machines<br />

Moreover, frequency converters and motor systems are classified<br />

in efficiency classes, which permit an initial rough estimate<br />

of the potential saving. Definition of reference systems is a key<br />

aspect of this because they provide standard reference values.<br />

The positioning of these reference systems defines the efficiency<br />

class. The relative distance from the reference system can be<br />

used as an absolute measure of the efficiency at the operating<br />

point in question.<br />

%<br />

Load torque M = constant<br />

Load torque M ~ 1/n<br />

50<br />

Relative speed<br />

%<br />

%<br />

100<br />

G_D011_EN_00467<br />

100<br />

100<br />

1<br />

Siemens D 31.5 · March <strong>2020</strong><br />

1/9


© Siemens <strong>2020</strong><br />

System overview<br />

1<br />

Energy efficiency classes in accordance with EN 50598<br />

■ Overview<br />

Advantages of the detailed loss consideration of EN 50598<br />

over the previous consideration of efficiencies and<br />

maximum loss values<br />

For motors, the efficiency consideration was previously only<br />

defined for operation without a converter at 50/60 Hz. It provides<br />

a good way of comparing the energy efficiency of motors from<br />

different manufacturers for this use case.<br />

The more detailed loss analysis of EN 50598, on the other hand,<br />

is aimed at speed-<strong>control</strong>led operation and therefore now also<br />

includes motors especially designed for converter operation in<br />

the energy analysis. These were previously not covered by the<br />

applicable standards.<br />

Moreover, a loss analysis over the entire setting and load range<br />

of the motor is possible. This is done in accordance with the<br />

standard EN 50598 with typical values.<br />

For holistic consideration, it is essential to include all the relevant<br />

components of a drive system. The EN 50598 standard defines<br />

this in detail. The standardized expression of power loss data<br />

as a percentage makes comparison considerably easier and<br />

more transparent.<br />

The method also makes it possible to consider a motor that<br />

produces a holding torque at speed zero, for example. In this<br />

case, the efficiency is zero, but a power loss from current producing<br />

magnetization and holding torque does occur. In summary,<br />

the key advantage of standard EN 50598 is the ability to<br />

perform the energy analysis of an electrical drive system based<br />

on standardized load profiles in all operating ranges due to uniform<br />

general conditions. This provides the user with <strong>complete</strong><br />

transparency irrespective of the manufacturer.<br />

Establishing efficiency classes of frequency converters<br />

(Complete Drive Modules CDM)<br />

To avoid overmodulation and to ensure comparability between<br />

makes, which cannot be achieved otherwise, the efficiency<br />

classes of CDMs refer to the 90/100 operating point (90 % motor<br />

stator frequency, 100 % torque current).<br />

Standard EN 50598-2 defines the relative losses of a CDM in<br />

efficiency classes IE0 to IE2. With reference to the value of a<br />

CDM of efficiency class IE1 (reference converter), a CDM of<br />

efficiency class IE2 has 25 % lower losses and a CDM of<br />

efficiency class IE0 has 25 % higher losses.<br />

Operating points for CDMs<br />

Relative<br />

torque current<br />

100 p CDM (0, 100) p CDM (50, 100) p CDM<br />

(90, 100)<br />

%<br />

50<br />

25<br />

0<br />

0<br />

Determination of the<br />

efficiency classes IE0 to IE2<br />

p CDM<br />

(0, 50)<br />

p CDM<br />

(0, 25)<br />

p CDM<br />

(50, 50)<br />

p CDM<br />

(50, 25)<br />

50 %<br />

Relative motor stator frequency<br />

90<br />

p CDM<br />

(90, 50)<br />

G_D011_EN_00468<br />

100<br />

p CDM<br />

(90, 100)<br />

p RCDM<br />

(90, 100)<br />

Reference value<br />

(reference converter)<br />

125%<br />

100%<br />

75%<br />

50%<br />

IE0<br />

IE1<br />

IE2<br />

25% greater losses<br />

than reference value<br />

Reference value ±25%<br />

25% lower losses than<br />

reference value<br />

Complete Drive Module (CDM) – determining the efficiency class<br />

Establishing the efficiency classes of drive systems<br />

(Power Drive Systems PDS)<br />

What is possible for the individual systems, of course, also<br />

applies to the entire electrical PDS (frequency converter plus<br />

motor). Detailed comparisons are now possible at this level, too.<br />

The reference values for the reference system provide clear<br />

indications of the energy performance of the PDS.<br />

Because targeted matching of the motor and CDM provides<br />

additional potential for optimization in electrical drive systems, it<br />

is especially important for the user to consider the entire drive<br />

system.<br />

For the efficiency class of a PDS, too, a specific load point is<br />

defined. In this case, the reference point used is the 100/100<br />

operating point (100 % motor stator frequency, 100 % torque).<br />

Standard EN 50598-2 defines the relative losses of a PDS in<br />

efficiency classes IES0 to IES2. With reference to the value of<br />

a PDS of efficiency class IES1 (reference drive), a PDS of<br />

efficiency class IES2 has 20 % lower losses and a PDS of<br />

efficiency class IES0 has 20 % higher losses.<br />

1/10 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

System overview<br />

■ Overview<br />

Operating points for PDS<br />

Energy efficiency classes in accordance with EN 50598<br />

1<br />

Motor losses<br />

CDM losses<br />

(Complete Drive Modules, frequency converters)<br />

100<br />

p RM<br />

(100, 100)<br />

100 p CDM (0, 100) p CDM (50, 100) p CDM<br />

(90, 100)<br />

%<br />

%<br />

Relative<br />

torque current<br />

50<br />

25<br />

Relative<br />

torque current<br />

50<br />

25<br />

p CDM<br />

(0, 50)<br />

p CDM<br />

(0, 25)<br />

p CDM<br />

(50, 50)<br />

p CDM<br />

(50, 25)<br />

p CDM<br />

(90, 50)<br />

0<br />

0<br />

50 %<br />

Relative speed<br />

100<br />

0<br />

0<br />

50 %<br />

Relative motor stator frequency<br />

90<br />

100<br />

PDS losses<br />

(Power Drive System)<br />

100 p PDS (0, 100) p PDS (50, 100) p PDS<br />

(100, 100)<br />

%<br />

Determination of the<br />

efficiency classes IES0 to IES2<br />

Relative torque<br />

p PDS<br />

(0, 50)<br />

50<br />

p PDS<br />

(0, 25)<br />

25<br />

0<br />

0<br />

p PDS<br />

(50, 50)<br />

p PDS<br />

(50, 25)<br />

50 %<br />

Relative speed<br />

90<br />

100<br />

p PDS<br />

(100, 50)<br />

G_D011_EN_00469<br />

Reference value<br />

(reference system =<br />

reference converter<br />

+ reference motor)<br />

p PDS<br />

(100, 100)<br />

p RPDS<br />

(100, 100)<br />

120%<br />

100%<br />

80%<br />

50%<br />

IES0<br />

IES1<br />

IES2<br />

20% greater losses<br />

than reference value<br />

Reference value ±20%<br />

20% lower losses than<br />

reference value<br />

Power Drive System (PDS) – determining the efficiency class<br />

■ More information<br />

An example of a highly efficient drive system with efficiency<br />

class IES2 is the new synchronous inductance drive system with<br />

SIMOTICS reluctance motors and SINAMICS <strong>drives</strong>.<br />

More information is available on the Internet at<br />

www.siemens.com/<strong>drives</strong>ystem-reluctance<br />

www.siemens.com/simotics-gp<br />

www.siemens.com/simotics-sd<br />

Power loss data of SINAMICS converters for single-axis <strong>drives</strong><br />

are available on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

More information on current laws and standards, new standards,<br />

and mandatory guidelines is available on the Internet at<br />

www.siemens.com/legislation-and-standards<br />

Siemens D 31.5 · March <strong>2020</strong><br />

1/11


© Siemens <strong>2020</strong><br />

System overview<br />

1<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Overview<br />

SINAMICS G120X, frame sizes FSA to FSJ, degree of protection IP20,<br />

with IOP-2 Intelligent Operator Panel<br />

Easy handling, utmost reliability, superior efficiency and advanced<br />

digitalization - Siemens offers an answer to these trends<br />

with the SINAMICS G120X converter series. SINAMICS G120X is<br />

an innovative and user-friendly converter series that has been<br />

specifically developed for applications performed in infrastructure<br />

environments such as water/wastewater, but also for tasks<br />

in building automation. In this context, the converter supports,<br />

for example, pump, fan and compressor applications through<br />

numerous integrated functionalities and combines these in one<br />

device for the target sectors.<br />

The SINAMICS G120X converter is an integrated and efficient<br />

drive solution for a wide range of tasks. The system allows convenient<br />

handling through optimized user interfaces: IOP-2 Intelligent<br />

Operator Panel with graphic color display and the optional<br />

web server module SINAMICS G120 Smart Access - a Wi-Fibased<br />

web server solution. Thus, the SINAMICS G120X fulfils<br />

the request for an easy and fast setup of the devices during the<br />

commissioning phase. Further, experienced users can use the<br />

full flexibility of a SINAMICS converter and adjust the relevant<br />

application to their requirements.<br />

Totally integrated operation - this approach is also supported<br />

from ordering through to delivery. For example, all the major features<br />

of the converter are configured and displayed in the article<br />

number. The delivery includes the <strong>complete</strong> device - as configured<br />

- that means, the converter and the selected operator<br />

panel.<br />

In addition, SINAMICS G120X has an extremely rugged and reliable<br />

construction. The integrated DC link reactor with a maximum<br />

output of 250 kW and optional resistance to harmful gases<br />

up to environmental class 3C3 ensure a reliable, stable and<br />

largely robust operation.<br />

The converter system is fit for digitalization. Thanks to its full integration<br />

in the SINAMICS CONNECT 300 system, data from up<br />

to eight converters can be acquired and transferred to the<br />

MindSphere cloud solution. The MindSphere application<br />

"Analyze MyDrives" facilitates the evaluation of data - tailored to<br />

individual customer needs. This simplifies the acquisition and<br />

evaluation of converter conditions.<br />

Further, the SINAMICS G120X converter series provides innovative<br />

hardware and software functions, e.g. for <strong>control</strong>ling synchronous<br />

reluctance drive systems with SIMOTICS reluctance<br />

motors. In this way, the SINAMICS G120X converter series<br />

makes a substantial contribution towards saving energy and<br />

makes more careful use of our natural resources.<br />

Portfolio range<br />

The SINAMICS G120X converter series with degree of protection<br />

IP20/UL Open Type offers a seamless system approach in three<br />

different voltage rangeswith wide options of built-in communication<br />

interfaces including PROFINET, EtherNet/IP, USS,<br />

Modbus RTU, BACnet MS/TP and PROFIBUS DP:<br />

• 200 V to 240 V 3 AC: 0.75 kW to 55 kW (1 hp to 75 hp)<br />

• 380 V to 480 V 3 AC: 0.75 kW to 560 kW (1 hp to 700 hp)<br />

• 500 V to 690 V 3 AC: 3 kW to 630 kW (4 hp to 700 hp)<br />

User-friendliness<br />

A high degree of user-friendliness is one of the main characteristics<br />

of the SINAMICS G120X:<br />

• Operator panel with color display and extensive diagnostics<br />

functions (IOP-2 Intelligent Operator Panel)<br />

• Two different setup options are available: Standard and quick<br />

start with graphical user guidance<br />

• Optimized setups for pumps and fans in the web server module<br />

SINAMICS G120 Smart Access<br />

• SINAMICS SD card for storing parameter settings, cloning<br />

and local commissioning<br />

Integrated functionalities for the start/operational/stop<br />

phases of the application<br />

SINAMICS G120X is always preset, depending on the selected<br />

converter performance. Further, the following functions can be<br />

easily selected and parameterized:<br />

Start phase<br />

During the start phase, the following functions are supported by<br />

default:<br />

• Deragging mode for pumps for cleaning the pump system, improving<br />

efficiency and reducing wear<br />

• Pipe filling mode for preventing pressure shocks in pipeline<br />

systems<br />

• Two acceleration ramps for shorter start/stop times<br />

• Flying restart of the running motor for fast hot restart<br />

• Automatic restart function after power failure during short<br />

downtimes<br />

Operating phase<br />

During the operating phase, the following functions are supported<br />

by default:<br />

• Continued run mode with autonomous reduction of output and<br />

pulse frequency<br />

• PID <strong>control</strong>ler for autonomous closed-loop <strong>control</strong> mode, operated<br />

according to analog input values<br />

• Up to 16 variable-speed setpoints as fixed frequencies<br />

• Speed monitoring via sensor (pulse input)<br />

• Multi-pump <strong>control</strong> of up to four pumps<br />

• Protection against blocking, leakage, dry running and<br />

cavitation<br />

• Fire response mode for extended operation in case of emergency<br />

• Skip frequencies for skipping critical frequencies and avoiding<br />

vibration<br />

• Real time clock for switching over setpoints or <strong>control</strong>ling releases<br />

Stop phase<br />

During the stop phase, the following functions are supported by<br />

default:<br />

• STO (Safe Torque Off) according to IEC 615<strong>08</strong> SIL 3 and<br />

EN ISO 13489-1 PL e and Category 3.<br />

External components (e.g. safety relays) are necessary for using<br />

the STO safety function.<br />

• ON/OFF2 for an optimized braking ramp<br />

• Condensation protection for the motor<br />

• Frost protection function for the pump<br />

A detailed description of the functions and connection diagrams<br />

are included in the device documentation.<br />

1/12 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

System overview<br />

■ Overview<br />

Commissioning of complex applications<br />

Sample applications, which include the description and device<br />

setting, are provided for SINAMICS G120X.<br />

The following application descriptions are available:<br />

• Fan for exhaust air with closed-loop <strong>control</strong> of pressure and air<br />

quality<br />

• Fan for cooling tower with closed-loop <strong>control</strong> of the cooling<br />

water temperature<br />

• Fan for tunnel/parking garage with closed-loop <strong>control</strong> of air<br />

quality and essential service mode<br />

• Fan for supply air with closed-loop <strong>control</strong> of pressure, temperature,<br />

air quality and flowrate<br />

• Pumps with closed-loop <strong>control</strong> of the pressure<br />

• Pumps with closed-loop <strong>control</strong> of the filling level<br />

• Pumps for cooling circuits with closed-loop <strong>control</strong> of the temperature<br />

• Compressor with closed-loop <strong>control</strong> of the pressure<br />

• Vacuum pump with closed-loop <strong>control</strong> of the pressure<br />

Practical application examples and descriptions are available<br />

on the Internet at<br />

www.siemens.com/sinamics-applications<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

1<br />

Siemens D 31.5 · March <strong>2020</strong><br />

1/13


© Siemens <strong>2020</strong><br />

System overview<br />

1<br />

SINAMICS G120X Starter Kits<br />

■ Overview<br />

■ Selection and ordering data<br />

Description<br />

SINAMICS G120X Starter Kits<br />

Converter (380 ... 480 V 3 AC, PROFINET)<br />

with IOP-2 and SINAMICS G120 Smart<br />

Access<br />

• 0.75 kW, FSA, without integrated<br />

line filter<br />

• 0.75 kW, FSA, with integrated line<br />

filter Category C2<br />

• 3 kW, FSA, with integrated line<br />

filter Category C2<br />

• 7.5 kW, FSB, with integrated line<br />

filter Category C2<br />

NEW NEU<br />

NEW NEU<br />

NEW NEU<br />

NEW NEU<br />

Article No.<br />

6SL3200-0AE70-0AA0<br />

6SL3200-0AE72-0AA0<br />

6SL3200-0AE73-0AA0<br />

6SL3200-0AE74-0AA0<br />

G_D011_EN_00566<br />

SINAMICS G120X<br />

FSA with IOP-2<br />

(Intelligent Operator Panel)<br />

SINAMICS G120<br />

Smart Access<br />

(web server module)<br />

Example: SINAMICS G120X Starter Kit, frame size FSA, 0.75 kW, with<br />

IOP-2 Intelligent Operator Panel and SINAMICS G120 Smart Access<br />

A SINAMICS G120X Starter Kit comprises a SINAMICS G120X<br />

converter (380 ... 480 V 3 AC; PROFINET) with an IOP-2 Intelligent<br />

Operator Panel and a SINAMICS G120 Smart Access web<br />

server module.<br />

The delivery quantity is limited to three units per customer.<br />

The SINAMICS G120X Starter Kits can be perfectly combined<br />

with the SIMATIC Starter Kits. In this way simple drive tasks up<br />

to <strong>motion</strong> <strong>control</strong> applications can be quickly implemented.<br />

Further information on SIMATIC Starter Kits can be found at:<br />

www.siemens.com/s7-1200-starterkits<br />

www.siemens.com/s7-1500-starterkits<br />

1/14 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

2<br />

2/2 SINAMICS G120X infrastructure<br />

converters for HVAC/Water/Wastewater<br />

2/2 Overview<br />

2/3 Benefits<br />

2/4 Application<br />

2/4 Design<br />

2/5 Function<br />

2/6 Integration<br />

2/8 Configuration<br />

2/10 Selection and ordering data<br />

2/10 • SINAMICS G120X converters ·<br />

Degree of protection IP20/UL Open Type ·<br />

200 ... 240 V 3 AC<br />

2/11 - Configuration with line-side<br />

components<br />

2/13 - Configuration with load-side power<br />

components<br />

2/14 • SINAMICS G120X converters ·<br />

Degree of protection IP20/UL Open Type ·<br />

380 ... 480 V 3 AC<br />

2/15 - Configuration with line-side<br />

components<br />

2/17 - Configuration with load-side power<br />

components<br />

2/18 • SINAMICS G120X converters ·<br />

Degree of protection IP20/UL Open Type ·<br />

500 ... 690 V 3 AC<br />

2/19 - Configuration with line-side<br />

components<br />

2/21 - Configuration with load-side power<br />

components<br />

2/22 • Supplementary system components<br />

and spare parts for SINAMICS G120X<br />

converters<br />

2/23 Technical specifications<br />

2/46 Characteristic curves<br />

2/51 Dimensional drawings<br />

2/51 More information<br />

2/52 Supplementary system components<br />

2/52 Operator Panels<br />

2/53 • IOP-2 Intelligent Operator Panel<br />

2/56 • BOP-2 Basic Operator Panel<br />

2/57 Memory cards<br />

2/58 SINAMICS G120 Smart Access<br />

2/59 SINAMICS CONNECT 300 IoT Gateway<br />

2/60 SINAMICS G120X I/O Extension Module<br />

2/61 Push-through mounting frames<br />

for frame sizes FSA to FSG<br />

2/61 IP21 top covers<br />

for frame sizes FSA to FSG<br />

2/62 Wiring adapter for frame size FSG<br />

2/63 Installation kit for line-side cable<br />

connection, left, for frame size FSH<br />

2/63 Spare parts<br />

2/63 FPI board for frame sizes FSH and FSJ<br />

2/63 PSB board for frame sizes FSH and FSJ<br />

2/63 Current transformers<br />

for frame sizes FSH and FSJ<br />

2/64 Spare parts kit for Control Unit<br />

2/64 Shield connection kit for Control Unit<br />

2/64 Shield connection kits for Power Module<br />

2/64 Small parts assembly set<br />

for frame sizes FSD to FSG<br />

2/65 Terminal cover kits<br />

for frame sizes FSD to FSG<br />

2/65 Fan units<br />

2/65 Control Units<br />

Further information about SINAMICS G120X<br />

can be found on the Internet at<br />

www.siemens.com/sinamics-g120x<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Overview<br />

SINAMICS G120X, frame sizes FSA to FSJ, degree of protection IP20,<br />

with IOP-2 Intelligent Operator Panel<br />

Easy handling, utmost reliability, superior efficiency and advanced<br />

digitalization - Siemens offers an answer to these trends<br />

with the SINAMICS G120X converter series. SINAMICS G120X is<br />

an innovative and user-friendly converter series that has been<br />

specifically developed for applications performed in infrastructure<br />

environments such as water/wastewater, but also for tasks<br />

in building automation. In this context, the converter supports,<br />

for example, pump, fan and compressor applications through<br />

numerous integrated functionalities and combines these in one<br />

device for the target sectors.<br />

The SINAMICS G120X converter is an integrated and efficient<br />

drive solution for a wide range of tasks. The system allows convenient<br />

handling through optimized user interfaces: IOP-2 Intelligent<br />

Operator Panel with graphic color display and the optional<br />

web server module SINAMICS G120 Smart Access - a Wi-Fibased<br />

web server solution. Thus, the SINAMICS G120X fulfils<br />

the request for an easy and fast setup of the devices during the<br />

commissioning phase. Further, experienced users can use the<br />

full flexibility of a SINAMICS converter and adjust the relevant<br />

application to their requirements.<br />

Totally integrated operation - this approach is also supported<br />

from ordering through to delivery.<br />

For example, all the major features of the converter are configured<br />

and displayed in the article number. The delivery includes<br />

the <strong>complete</strong> device - as configured - that means, the converter<br />

and the selected operator panel.<br />

In addition, SINAMICS G120X has an extremely rugged and reliable<br />

construction. The integrated DC link reactor with a maximum<br />

output of 250 kW and optional resistance to harmful gases<br />

up to environmental class 3C3 ensure a reliable, stable and<br />

largely robust operation.<br />

The converter system is fit for digitalization. Thanks to its full integration<br />

in the SINAMICS CONNECT 300 system, data from up<br />

to eight converters can be acquired and transferred to the<br />

MindSphere cloud solution. The MindSphere application<br />

"Analyze MyDrives" facilitates the evaluation of data - tailored to<br />

individual customer needs. This simplifies the acquisition and<br />

evaluation of converter conditions.<br />

Further, the SINAMICS G120X converter series provides innovative<br />

hardware and software functions, e.g. for <strong>control</strong>ling synchronous<br />

reluctance drive systems with SIMOTICS reluctance<br />

motors. In this way, the SINAMICS G120X converter series<br />

makes a substantial contribution towards saving energy and<br />

makes more careful use of our natural resources.<br />

Portfolio range<br />

The SINAMICS G120X converter series with degree of protection<br />

IP20/UL Open Type offers a seamless system approach in three<br />

different voltage rangeswith wide options of built-in communication<br />

interfaces including PROFINET, EtherNet/IP, USS,<br />

Modbus RTU, BACnet MS/TP and PROFIBUS DP:<br />

• 200 V to 240 V 3 AC: 0.75 kW to 55 kW (1 hp to 75 hp)<br />

• 380 V to 480 V 3 AC: 0.75 kW to 560 kW (1 hp to 700 hp)<br />

• 500 V to 690 V 3 AC: 3 kW to 630 kW (4 hp to 700 hp)<br />

User-friendliness<br />

A high degree of user-friendliness is one of the main characteristics<br />

of the SINAMICS G120X:<br />

• Operator panel with color display and extensive diagnostics<br />

functions (IOP-2 Intelligent Operator Panel)<br />

• Two different setup options are available: Standard and quick<br />

start with graphical user guidance<br />

• Optimized setups for pumps and fans in the web server module<br />

SINAMICS G120 Smart Access<br />

• SINAMICS SD card for storing parameter settings, cloning<br />

and local commissioning<br />

Integrated functionalities for the start/operational/stop<br />

phases of the application<br />

SINAMICS G120X is always preset, depending on the selected<br />

converter performance. Further, the following functions can be<br />

easily selected and parameterized:<br />

Start phase<br />

During the start phase, the following functions are supported by<br />

default:<br />

• Deragging mode for pumps for cleaning the pump system, improving<br />

efficiency and reducing wear<br />

• Pipe filling mode for preventing pressure shocks in pipeline<br />

systems<br />

• Two acceleration ramps for shorter start/stop times<br />

• Flying restart of the running motor for fast hot restart<br />

• Automatic restart function after power failure during short<br />

downtimes<br />

Operating phase<br />

During the operating phase, the following functions are supported<br />

by default:<br />

• Continued run mode with autonomous reduction of output and<br />

pulse frequency<br />

• PID <strong>control</strong>ler for autonomous closed-loop <strong>control</strong> mode, operated<br />

according to analog input values<br />

• Up to 16 variable-speed setpoints as fixed frequencies<br />

• Speed monitoring via sensor (pulse input)<br />

• Multi-pump <strong>control</strong> of up to four pumps<br />

• Protection against blocking, leakage, dry running and<br />

cavitation<br />

• Fire response mode for extended operation in case of emergency<br />

• Skip frequencies for skipping critical frequencies and avoiding<br />

vibration<br />

• Real time clock for switching over setpoints or <strong>control</strong>ling releases<br />

Stop phase<br />

During the stop phase, the following functions are supported by<br />

default:<br />

• STO (Safe Torque Off) according to IEC 615<strong>08</strong> SIL 3 and<br />

EN ISO 13489-1 PL e and Category 3.<br />

External components (e.g. safety relays) are necessary for using<br />

the STO safety function.<br />

• ON/OFF2 for an optimized braking ramp<br />

• Condensation protection for the motor<br />

• Frost protection function for the pump<br />

A detailed description of the functions and connection diagrams<br />

are included in the device documentation.<br />

2/2 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

■ Overview<br />

Commissioning of complex applications<br />

Sample applications, which include the description and device<br />

setting, are provided for SINAMICS G120X.<br />

The following application descriptions are available:<br />

• Fan for exhaust air with closed-loop <strong>control</strong> of pressure and air<br />

quality<br />

• Fan for cooling tower with closed-loop <strong>control</strong> of the cooling<br />

water temperature<br />

• Fan for tunnel/parking garage with closed-loop <strong>control</strong> of air<br />

quality and essential service mode<br />

• Fan for supply air with closed-loop <strong>control</strong> of pressure, temperature,<br />

air quality and flowrate<br />

• Pumps with closed-loop <strong>control</strong> of the pressure<br />

• Pumps with closed-loop <strong>control</strong> of the filling level<br />

• Pumps for cooling circuits with closed-loop <strong>control</strong> of the temperature<br />

• Compressor with closed-loop <strong>control</strong> of the pressure<br />

• Vacuum pump with closed-loop <strong>control</strong> of the pressure<br />

Practical application examples and descriptions are available<br />

on the Internet at<br />

www.siemens.com/sinamics-applications<br />

■ Benefits<br />

Energy efficiency<br />

SINAMICS G120X increases the efficiency and minimizes energy<br />

consumption in the <strong>complete</strong> process chain. The converter<br />

has integrated hardware as well as software functions as standard.<br />

The main features are:<br />

• Power units with DC link reactor for extremely high active<br />

power component thanks to efficient converter topology - for<br />

the same drive power, the converter requires a lower line current<br />

than comparable converters<br />

• Flux reduction through automatic adaptation of the motor current<br />

to the prevailing load conditions with closed-loop <strong>control</strong><br />

modes V/f (ECO) and vector without sensor (SLVC) and savings<br />

of up to 5 % under partial load conditions<br />

• Hibernation mode dependent on setpoints in the process<br />

• High efficiency ≥ 98 %<br />

Application-specific commissioning and operation using<br />

operator panel<br />

• Local commissioning without specialized knowledge of converters<br />

thanks to default settings and graphical user interface<br />

• Unique: SINAMICS SD memory card for pre-parameterization<br />

and cloning of converter data sets<br />

• Data backup for easy replacement<br />

• Commissioning/diagnostics and <strong>control</strong>ling of converters<br />

Flexible deployment of integrated functions<br />

• PLC functions for local <strong>control</strong> tasks for frame sizes FSA to<br />

FSG<br />

Flexible use of integrated function blocks<br />

No need for additional, external components<br />

• Four integrated PID <strong>control</strong>lers<br />

Distributed closed-loop <strong>control</strong> for motor-independent process<br />

<strong>control</strong> without higher-level <strong>control</strong>ler (PLC)<br />

• Three freely programmable digital timer switches<br />

Control for freely selectable daily and weekly programs<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Flexible deployment across a wide range of applications<br />

• Isolated digital inputs with separate potential group<br />

• Isolated analog inputs<br />

- Potential transfer avoided<br />

- EMC-compliant design without the need for additional components<br />

in line with process industry requirements<br />

• Direct connection of Pt1000/Ni1000 temperature sensors with<br />

optional SINAMICS G120X I/O Extension Module<br />

• Connection and evaluation of a recommended, optional Pt100<br />

temperature sensor by using a free analog input and output<br />

• 2/3-wire <strong>control</strong> for static/pulsed signals for universal <strong>control</strong><br />

via digital inputs<br />

• 230 V AC relay<br />

- Direct <strong>control</strong> for auxiliary equipment, e.g. reactor or valve<br />

actuators<br />

• Safety functions<br />

- Terminals for <strong>control</strong>ling the STO (Safe Torque Off) Safety<br />

function according to IEC 615<strong>08</strong> SIL 3 and EN ISO 13489-1<br />

PL e and Category 3.<br />

External components (e.g. safety relays) are necessary for<br />

using the STO safety function.<br />

For further information see the operating instructions<br />

www.siemens.com/sinamics-g120x/documentation<br />

• X9 terminal strip for devices in frame sizes FSH and FSJ<br />

(315 kW to 630 kW)<br />

- Input for external 24 V DC supply<br />

- Input for external alarm/fault<br />

- Input for EMERGENCY OFF/EMERGENCY STOP<br />

- Output for 24 V DC<br />

- Control of the main contactor<br />

- Feedback message "DC link charged"<br />

• Use of the communication versions at ambient<br />

temperatures of<br />

- -20 °C to +55 °C: PROFINET, EtherNet/IP<br />

- -20 °C to +60 °C: PROFIBUS DP, USS, Modbus RTU, BACnet<br />

MS/TP<br />

• Removable operator panel<br />

- Protection against unauthorized access<br />

- Color-coded signaling of operating states<br />

• Replacement of individual components without the need for<br />

reinstallation<br />

- Plug-in version of <strong>control</strong> terminals (for replacement without<br />

removing wiring)<br />

• Version for harsh environmental conditions<br />

- Coated modules for increased resistance to humidity and<br />

dust (Class 3C2)<br />

- PCB coating for environmental class/harmful chemical substances<br />

Class 3C3 acc. to IEC 60721-3-3: 2002<br />

Extended warranty<br />

Siemens offers for SINAMICS G120X an extended warranty<br />

up to 7½ years:<br />

• 24 months of standard warranty<br />

• Optional extension via Service Protect<br />

- 6 months free of charge after product registration at:<br />

https://myregistration.siemens.com<br />

- chargeable for additional 3 or 5 years<br />

More information at:<br />

https://support.industry.siemens.com/cs/ww/en/sc/4842<br />

2<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/3


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

2<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Application<br />

The specialist for pump, fan and compressor applications<br />

SINAMICS G120X is ideally suited to pump applications (centrifugal<br />

pumps, oscillating and rotating pumps), fan applications<br />

(axial and radial fans) and compressor applications (cooling<br />

compressors, air and gas compressors). They are deployed in<br />

the water/waste water industries, in industrial environments, and<br />

in building automation.<br />

SINAMICS G120X is ideally suited for the following applications:<br />

• Circulating pumps for heating and cooling systems<br />

• Pumps for pressure boosting stations<br />

• Level <strong>control</strong><br />

• Fans in cooling towers<br />

• Fans for air intake and discharge<br />

• Fans for tunnels and multi-story car parks<br />

• Fans for stairwells<br />

• Compressors for cooling units<br />

Reliable operation in harsh environments<br />

SINAMICS G120X is suitable for use under harsh environmental<br />

conditions:<br />

• Degree of protection IP20/UL Open Type for use in the <strong>control</strong><br />

cabinet<br />

• Degree of protection IP21 with optional IP21 top cover for use<br />

in lockable <strong>control</strong> rooms, including outside a <strong>control</strong> cabinet<br />

• Degree of protection IP20 with optional push-through mounting<br />

frame for space-saving design when installed in the <strong>control</strong><br />

cabinet; power losses are dissipated using an external<br />

heat sink, separate internal air circulation<br />

• Use of the communication versions at ambient<br />

temperatures of<br />

- -20 °C to +55 °C: PROFINET, EtherNet/IP<br />

- -20 °C to +60 °C: PROFIBUS DP, USS, Modbus RTU, BACnet<br />

MS/TP<br />

• Coated modules for increased resistance to humidity and dust<br />

(Class 3C2)<br />

• Optional for environmental class/harmful chemical substances<br />

Class 3C3 acc. to IEC 60721-3-3: 2002<br />

■ Design<br />

SINAMICS G120X is a converter system that comprises a power<br />

output module and a <strong>control</strong> module with or without an operator<br />

panel.<br />

The converter is configured on the basis of the power requirement<br />

and the application. State-of-the-art IGBT technology with<br />

pulse-width modulation is used for reliable and flexible motor operation.<br />

Comprehensive protection functions provide a high degree<br />

of protection for the converter and motor.<br />

The SINAMICS G120X converters in degree of protection IP20<br />

are intended for installation in a <strong>control</strong> cabinet.<br />

• Selection of the line filter for line voltage 200 V to 240 V 3 AC<br />

- Without integrated line filter, 0.75 kW to 55 kW<br />

• Selection of the line filter for line voltage 380 V to 480 V 3 AC<br />

- Without integrated line filter, 0.75 kW to 132 kW<br />

- With integrated line filter Category C2, 0.75 kW to 250 kW<br />

- With integrated line filter Category C3, 160 kW to 560 kW<br />

- With additional line filter Category C1 for unfiltered devices,<br />

0.75 kW to 110 kW<br />

- With additional line filter Category C2 for filtered devices,<br />

315 kW to 560 kW<br />

• Selection of the line filter for line voltage 500 V to 690 V 3 AC<br />

- Without integrated line filter, 3 kW to 132 kW<br />

- With integrated line filter Category C2, 3 kW to 55 kW<br />

- With integrated line filter Category C3, 75 kW to 630 kW<br />

- With additional line filter Category C2 for filtered devices,<br />

315 kW to 630 kW<br />

• Environmental class/harmful chemical substances acc. to IEC<br />

60721-3-3: 2002<br />

- Class 3C2<br />

-Class3C3<br />

• Selection of communication<br />

- PROFINET, EtherNet/IP<br />

- PROFIBUS<br />

- USS, Modbus RTU, BACnet MS/TP<br />

• Selection of the operator panel<br />

The operator panels support user-friendly local commissioning,<br />

<strong>control</strong> and diagnostics and enable <strong>complete</strong> converter<br />

data sets to be pre-parameterized and cloned.<br />

- Without operator panel<br />

- BOP-2 Basic Operator Panel<br />

The menu prompting and the 2-line display allow for simple<br />

commissioning of the converter. Simultaneous display of the<br />

parameter and parameter value, as well as parameter filtering,<br />

means that basic commissioning of a drive can also be<br />

performed without a printed parameter list.<br />

- IOP-2 Intelligent Operator Panel<br />

Supports entry-level personnel as well as drive experts.<br />

Thanks to the color display, a user-friendly menu structure<br />

and wizards, it is much easier to commission, diagnose and<br />

locally <strong>control</strong> standard <strong>drives</strong>.<br />

Line-side power components<br />

The following line-side power components are available for the<br />

SINAMICS G120X converters:<br />

• Line filters for categories C1, C2 and C3, see above<br />

With an additional line filter, the converter complies with a<br />

higher radio interference class.<br />

• Line harmonics filters for frame sizes FSB from 5.5 kW to FSG<br />

up to 250 kW<br />

The use of a line harmonics filter enables a significant reduction<br />

in unwanted harmonics. This means that a THD (I) value<br />

of less than 5 % can be achieved and compliance with the<br />

limit values according to IEC 61000-3-12, IEC 61000-2-2 and<br />

IEEE 519 is possible regardless of the network impedance.<br />

• Line reactors for devices from 315 kW and for frame sizes FSH<br />

and FSJ<br />

Line reactors smooth the current drawn by the converter and<br />

thus reduce harmonic components in the line current. Through<br />

the reduction of the current harmonics, the thermal load on the<br />

power components in the rectifier and in the DC link capacitors<br />

is reduced as well as the harmonic effects on the supply.<br />

The use of a line reactor increases the service life of the<br />

converter.<br />

SINAMICS G120X frame sizes FSA to FSG feature an integrated<br />

DC link reactor as standard. The use of an additional<br />

line reactor is not necessary for this.<br />

Recommended line-side overcurrent protection devices and<br />

power components<br />

This section contains recommendations for additional line-side<br />

components, such as Siemens fuses and circuit breakers (lineside<br />

components must be dimensioned in accordance with IEC<br />

standards).<br />

Additional information about the listed fuses and circuit breakers<br />

is available in the Catalogs LV 10, IC 10 and IC 10 AO as well as<br />

in the Industry Mall.<br />

2/4 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Design<br />

Load-side power components<br />

Various load-side power components are available for the<br />

SINAMICS G120X converters. These allow the use of longer<br />

shielded motor cables and increase the motor service life:<br />

• Output reactors for frame sizes FSD to FSJ<br />

Output reactors reduce the rate of voltage rise (dv/dt) and the<br />

height of the current peaks, and can allow longer motor cables<br />

to be connected.<br />

• Sine-wave filters for frame sizes FSA to FSF<br />

Sine-wave filters limit the rate of voltage rise (dv/dt) and the<br />

peak voltages on the motor winding. Similar to an output reactor,<br />

they enable the connection of longer motor cables.<br />

• dv/dt filters plus VPL for frame sizes FSD to FSJ<br />

dv/dt filters plus VPL (Voltage Peak Limiter) limit the voltage<br />

rate-of-rise dv/dt to values of


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Integration<br />

Memory<br />

card<br />

IOP-2<br />

BOP-2<br />

1<br />

+10 V OUT<br />

2<br />

GND<br />

2<br />

≥ 4.7 kΩ<br />

Pt100<br />

DI0<br />

DI1<br />

DI2<br />

DI3<br />

DI4<br />

DI5<br />

+<br />

24 V<br />

5<br />

6<br />

7<br />

8<br />

16<br />

17<br />

69<br />

3<br />

4<br />

AI0-<br />

AI0+<br />

AI0-<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

28 GND<br />

69<br />

AI0+<br />

11 AI1-<br />

10 AI1+<br />

DI0<br />

DI1<br />

DI2<br />

DI3<br />

16 DI4<br />

17 DI5<br />

+24 V OUT<br />

DI COM<br />

A<br />

A<br />

Digital inputs<br />

D<br />

D<br />

ON<br />

OFF<br />

DIP switch<br />

Analog inputs<br />

0 to 20 mA<br />

AI0<br />

AI1<br />

0 to 10 V<br />

SINAMICS G120X<br />

Power Module<br />

L1<br />

IOP-2<br />

Handheld<br />

I/O Extension<br />

Module<br />

SINAMICS<br />

G120<br />

Smart<br />

Access<br />

PTC/KTY/<br />

Pt1000<br />

0 to 10 V<br />

0 to 20 mA<br />

max. 500 Ω<br />

DO0<br />

DO1<br />

14<br />

15<br />

12<br />

13<br />

20<br />

19<br />

18<br />

25<br />

24<br />

23<br />

31<br />

32<br />

T1 MOTOR<br />

T2 MOTOR<br />

AO0+<br />

GND<br />

COM<br />

NO<br />

NC<br />

COM<br />

NO<br />

NC<br />

+24 V IN<br />

GND IN<br />

A<br />

A<br />

D<br />

D<br />

from<br />

external<br />

source<br />

PM interface<br />

STO enable<br />

STO switches<br />

Line supply<br />

DC link<br />

Motor<br />

STO<br />

L2<br />

L3<br />

Ground<br />

R1 (FSA - FSG)<br />

DCP (FSH - FSJ)<br />

F3 (FSA - FSG)<br />

DCN (FSH - FSJ)<br />

U2<br />

V2<br />

W2<br />

Ground<br />

STO_A 24 V<br />

STO_A 0 V<br />

STO_B 24 V<br />

STO_B 0 V<br />

SINAMICS<br />

CONNECT 300<br />

IoT Gateway<br />

Communications<br />

interface<br />

G_D011_EN_00589b<br />

SINAMICS G120X connection diagram<br />

2/6 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Integration<br />

5<br />

X21<br />

4<br />

6<br />

2<br />

G_D011_EN_00591<br />

3<br />

2<br />

7<br />

X132<br />

X134<br />

1<br />

8<br />

X133<br />

9<br />

X126 / X128 / X150<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

9<br />

8<br />

Terminal strip<br />

Switch for AI 0 and AI 1 (I/V)<br />

Status LED<br />

Connection to Operator Panel, Smart Access or I/O Extension Module<br />

Memory card slot<br />

For mounting the I/O Extension Module<br />

Terminal strips<br />

Fieldbus interfaces on the bottom<br />

SINAMICS G120X interface overview<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/7


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Configuration<br />

The following electronic configuring guides and engineering<br />

tools are available for SINAMICS G120X converters:<br />

SINAMICS SELECTOR app<br />

Mobile selection guide for frequency converters<br />

Siemens has developed the SINAMICS SELECTOR app as a<br />

practical tool for finding article numbers for your SINAMICS converters<br />

in the power range from 0.12 kW to 630 kW quickly and<br />

easily. Whether for SINAMICS V20, SINAMICS G120C,<br />

SINAMICS G120P, SINAMICS G120X or SINAMICS G120:<br />

The app will provide you with the correct article numbers<br />

conveniently.<br />

How does it work? Simply select your application, the frequency<br />

converter you require, the rated power and device options as<br />

well as the necessary accessories.<br />

Then you can save your selection and send it by email. Your preselection<br />

is the basis for an order specification with the<br />

dealer/Siemens.<br />

You will find the free downloads for Android and for iOS at the following<br />

link:<br />

www.siemens.com/sinamics-selector<br />

SINAMICS ASSISTANT app<br />

The error code function of the SINAMICS ASSISTANT app helps<br />

you to identify and rectify errors. Just enter the error code of your<br />

frequency converter and the app shows you what sort of error it<br />

is and how you can rectify it.<br />

This app also recalculates for you the frequency (Hz) of a frequency<br />

converter into the speed to be set on the motor (rpm) or<br />

vice versa.<br />

In addition, this app offers you a support page on which you can<br />

get in touch straight away with the right contact person in your<br />

region if you have any questions. Furthermore, video information<br />

is available to you free of charge, e.g. on installation and commissioning<br />

of the SINAMICS G120 frequency converter.<br />

You will find the free downloads for Android and for iOS at the following<br />

link:<br />

www.siemens.com/sinamics-assistant<br />

Drive Technology Configurator (DT Configurator)<br />

The DT Configurator can be used on the Internet without requiring<br />

any installation. The DT Configurator can be found in the Siemens<br />

Industry Mall at the following address:<br />

www.siemens.com/dt-configurator<br />

You can find further information on the Drive Technology<br />

Configurator (DT Configurator) in the Engineering tools section.<br />

TIA Selection Tool<br />

Selection tool and configurator for automation technology<br />

Flawless configuration without expert knowledge through intelligent<br />

configurators and selection wizards. Desktop and cloud<br />

versions enable cross-team work with maximum flexibility.<br />

There are two versions of the TIA Selection Tool:<br />

• One for downloading and executing on Windows PCs<br />

(from Microsoft Windows 7)<br />

• One for running from the cloud, which is launched from mobile<br />

devices directly in the browser<br />

(we recommend Safari, Chrome and Firefox)<br />

Projects stored in the cloud can be edited with both tools. This<br />

makes it possible to work on-the-go using a tablet, at home on a<br />

PC – and vice versa, or together with colleagues and customers.<br />

In order to use the full functionality, we recommended setting up<br />

a Siemens Industry Mall account for both cases. This gives you<br />

access to prices and enables you to save your projects to our<br />

cloud.<br />

You can find more information on the TIA Selection Tool at<br />

www.siemens.com/tia-selection-tool<br />

SIMARIS planning tools for plants with SINAMICS <strong>drives</strong><br />

Electrical planning: Even easier with software!<br />

Electrical planning for power distribution in non-residential and<br />

industrial buildings has never been more complex. To ensure<br />

you, as a specialist planner, have the best hand when it comes<br />

to electrical planning with SINAMICS <strong>drives</strong>, we provide support<br />

with the following efficient software tools: SIMARIS design for dimensioning<br />

and SIMARIS project for calculating the space requirements<br />

of the distribution boards.<br />

You can find more information on the SIMARIS planning tools for<br />

plants with SINAMICS <strong>drives</strong> in the Engineering tools section.<br />

SinaSave energy efficiency tool (available soon)<br />

Use SinaSave to calculate potential energy savings<br />

The web-based tool SinaSave can be used to estimate the potential<br />

savings which can be achieved over the entire lifecycle,<br />

e.g. for pump and fan applications, thanks to SINAMICS. The<br />

tool takes into consideration all important plant-specific quantities,<br />

such as the power and load data of the application, the relevant<br />

<strong>control</strong> mode and the operation profile for the application<br />

in question. The result delivered by the tool specifies the potential<br />

energy savings which can be achieved with the specific application<br />

in conjunction with the Integrated Drive System or the<br />

drive component. The tool also provides a monetary evaluation<br />

of the potential savings and estimates the payback period.<br />

You can find more information about the amortization calculator<br />

for energy-efficient drive systems at<br />

www.siemens.com/sinasave<br />

You can find further information on the SinaSave energy<br />

efficiency tool in the Engineering tools section.<br />

2/8 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Configuration<br />

SIZER for Siemens Drives engineering tool<br />

The SIZER for Siemens Drives engineering tool makes it easy to<br />

configure the SINAMICS converter family. It provides support<br />

when selecting the hardware and firmware components necessary<br />

to implement a drive task. SIZER for Siemens Drives is designed<br />

to support configuring of the entire drive system.<br />

The SIZER for Siemens Drives engineering tool is available free<br />

on the Internet at<br />

www.siemens.com/sizer<br />

You can find further information on the SIZER for Siemens Drives<br />

engineering tool in the Engineering tools section.<br />

Drive ES PCS 7 engineering system<br />

Drive ES PCS 7 integrates <strong>drives</strong> into the SIMATIC PCS 7 process<br />

<strong>control</strong> system. Drive ES PCS 7 provides a block library<br />

with blocks for the <strong>drives</strong> and the corresponding faceplates for<br />

the operator station.<br />

More information about the Drive ES engineering system is available<br />

on the Internet at<br />

www.siemens.com/drive-es<br />

SINAMICS web server for SINAMICS G120X via<br />

SINAMICS G120 Smart Access<br />

Web server for efficient commissioning, diagnostics and<br />

maintenance<br />

The optionally available SINAMICS G120 Smart Access provides<br />

the SINAMICS G120X drive system with a web server for<br />

efficient commissioning, diagnostics and maintenance. The web<br />

server provides access to a multi-faceted range of new options<br />

for parameter assignment and drive diagnostics for laptops, tablets<br />

and smartphones.<br />

You can find further information on the SINAMICS web server for<br />

SINAMICS G120X via SINAMICS G120 Smart Access in the<br />

Engineering tools section.<br />

2<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/9


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Selection and ordering data<br />

NEW NEU<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 200 ... 240 V 3 AC ➡ Configuration with line-side components (see right page)<br />

Rated power 1) Rated output current 2) Base-load current<br />

I 3)<br />

H<br />

Rated input<br />

current 4) Frame size SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

without integrated line filter<br />

2<br />

200 V 240 V 200 V 240 V 200 V 240 V 200 V<br />

kW hp A A A A A Article No.<br />

200 ... 240 V 3 AC · Rated pulse frequency 4 kHz · Input frequency 47 ... 63 Hz<br />

0.75 1 4.2 4.2 3.2 3.2 3.8 FSA 6SL32 ■ 0- ■ YC10- ■ U ■ 0<br />

1.1 1.5 6 6 4.2 4.2 5.4 FSA 6SL32 ■ 0- ■ YC12- ■ U ■ 0<br />

1.5 2 7.4 7.4 6 6 6.7 FSA 6SL32 ■ 0- ■ YC14- ■ U ■ 0<br />

2.2 3 10.4 10.4 7.4 7.4 9.6 FSB 6SL32 ■ 0- ■ YC16- ■ U ■ 0<br />

3 4 13.6 13.6 10.4 10.4 12.7 FSB 6SL32 ■ 0- ■ YC18- ■ U ■ 0<br />

4 5 17.5 17.5 13.6 13.6 16.3 FSB 6SL32 ■ 0- ■ YC20- ■ U ■ 0<br />

5.5 7.5 22 22 17.5 17.5 20.8 FSC 6SL32 ■ 0- ■ YC22- ■ U ■ 0<br />

7.5 10 28 28 22 22 26.3 FSC 6SL32 ■ 0- ■ YC24- ■ U ■ 0<br />

11 15 42 42 28 28 40 FSD 6SL32 ■ 0- ■ YC26- ■ U ■ 0<br />

15 20 54 54 42 42 51 FSD 6SL32 ■ 0- ■ YC28- ■ U ■ 0<br />

18.5 25 68 68 54 54 64 FSD 6SL32 ■ 0- ■ YC30- ■ U ■ 0<br />

22 30 80 80 68 68 76 FSE 6SL32 ■ 0- ■ YC32- ■ U ■ 0<br />

30 40 104 104 80 80 98 FSE 6SL32 ■ 0- ■ YC34- ■ U ■ 0<br />

37 50 130 130 104 104 126 FSF 6SL32 ■ 0- ■ YC36- ■ U ■ 0<br />

45 60 154 154 130 130 149 FSF 6SL32 ■ 0- ■ YC38- ■ U ■ 0<br />

55 75 192 192 154 154 172 FSF 6SL32 ■ 0- ■ YC40- ■ U ■ 0<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 2<br />

Class 3C3 3<br />

Operator Panel<br />

Without Operator Panel 1<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension 0<br />

With SINAMICS G120X I/O Extension Module 1<br />

Line filter<br />

Without integrated line filter<br />

U<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP<br />

B<br />

PROFINET, EtherNet/IP<br />

F<br />

PROFIBUS DP<br />

P<br />

1) Rated power based on the base-load current I L . The base-load current I L<br />

is based on the duty cycle for low overload (LO).<br />

2) The rated output current is based on the duty cycle for low overload (LO).<br />

These current values are valid for 200 V or 240 V.<br />

3) The base-load current I H is based on the duty cycle for high overload (HO).<br />

These current values are valid for 200 V or 240 V.<br />

4) The input current depends on the motor load and line impedance.<br />

The input currents apply for a load at rated power (based on I L ) for a line<br />

impedance corresponding to u K = 1 %. The current values are specified on<br />

the rating plate of the converter.<br />

2/10 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Line-side components (Configuration with load-side power components see next double page)<br />

Line filters Line harmonics filters Line reactors Recommended line-side<br />

Category C2<br />

Category C1<br />

overcurrent protection devices 1)<br />

Fuses<br />

IEC-compliant<br />

Fuses<br />

UL/cUL-compliant<br />

Rated voltage<br />

600 V AC 2)<br />

Current Fuse type Current<br />

Article No. Article No. Article No. A Article No. Class/Article No. A<br />

– – – A DC line reactor 16 3NA3805 J 15<br />

– – – is integrated for 16 3NA3805 J 15<br />

frame sizes<br />

– – –<br />

FSA to FSF –<br />

16 3NA3805 J 15<br />

– – – therefore no<br />

32 3NA3812 J 35<br />

– – – line reactor<br />

32 3NA3812 J 35<br />

is required.<br />

– – – 32 3NA3812 J 35<br />

– – – 50 3NA3820 J 50<br />

– – – 50 3NA3820 J 50<br />

– – – 63 3NA3822 J 60<br />

– – – 80 3NA3824 J 70<br />

– – – 100 3NA3830 J 90<br />

– – – 100 3NA3830 J 110<br />

– – – 160 3NA3836 J 150<br />

– – – 200 3NA3140 J 175<br />

– – – 200 3NA3140 J 200<br />

– – – 224 3NA3142 J 250<br />

2<br />

1) Further information at<br />

https://support.industry.siemens.com/cs/document/109762895<br />

2) The Short Circuit Current Rating (SCCR) according to UL for industrial <strong>control</strong><br />

panel installations to NEC Article 409 or UL 5<strong>08</strong>A/5<strong>08</strong>C or UL 61800-5-1<br />

is 100 kA for SINAMICS G120X.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/11


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Selection and ordering data<br />

NEW NEU<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 200 ... 240 V 3 AC ➡ Configuration with load-side power components (see right page)<br />

Rated power 1) Rated output current 2) Base-load current<br />

I 3)<br />

H<br />

Rated input<br />

current 4) Frame size SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

without integrated line filter<br />

2<br />

200 V 240 V 200 V 240 V 200 V 240 V 200 V<br />

kW hp A A A A A Article No.<br />

200 ... 240 V 3 AC · Rated pulse frequency 4 kHz · Input frequency 47 ... 63 Hz<br />

0.75 1 4.2 4.2 3.2 3.2 3.8 FSA 6SL32 ■ 0- ■ YC10- ■ U ■ 0<br />

1.1 1.5 6 6 4.2 4.2 5.4 FSA 6SL32 ■ 0- ■ YC12- ■ U ■ 0<br />

1.5 2 7.4 7.4 6 6 6.7 FSA 6SL32 ■ 0- ■ YC14- ■ U ■ 0<br />

2.2 3 10.4 10.4 7.4 7.4 9.6 FSB 6SL32 ■ 0- ■ YC16- ■ U ■ 0<br />

3 4 13.6 13.6 10.4 10.4 12.7 FSB 6SL32 ■ 0- ■ YC18- ■ U ■ 0<br />

4 5 17.5 17.5 13.6 13.6 16.3 FSB 6SL32 ■ 0- ■ YC20- ■ U ■ 0<br />

5.5 7.5 22 22 17.5 17.5 20.8 FSC 6SL32 ■ 0- ■ YC22- ■ U ■ 0<br />

7.5 10 28 28 22 22 26.3 FSC 6SL32 ■ 0- ■ YC24- ■ U ■ 0<br />

11 15 42 42 28 28 40 FSD 6SL32 ■ 0- ■ YC26- ■ U ■ 0<br />

15 20 54 54 42 42 51 FSD 6SL32 ■ 0- ■ YC28- ■ U ■ 0<br />

18.5 25 68 68 54 54 64 FSD 6SL32 ■ 0- ■ YC30- ■ U ■ 0<br />

22 30 80 80 68 68 76 FSE 6SL32 ■ 0- ■ YC32- ■ U ■ 0<br />

30 40 104 104 80 80 98 FSE 6SL32 ■ 0- ■ YC34- ■ U ■ 0<br />

37 50 130 130 104 104 126 FSF 6SL32 ■ 0- ■ YC36- ■ U ■ 0<br />

45 60 154 154 130 130 149 FSF 6SL32 ■ 0- ■ YC38- ■ U ■ 0<br />

55 75 192 192 154 154 172 FSF 6SL32 ■ 0- ■ YC40- ■ U ■ 0<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 2<br />

Class 3C3 3<br />

Operator Panel<br />

Without Operator Panel 1<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension 0<br />

With SINAMICS G120X I/O Extension Module 1<br />

Line filter<br />

Without integrated line filter<br />

U<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP<br />

B<br />

PROFINET, EtherNet/IP<br />

F<br />

PROFIBUS DP<br />

P<br />

1) Rated power based on the base-load current I L . The base-load current I L<br />

is based on the duty cycle for low overload (LO).<br />

2) The rated output current is based on the duty cycle for low overload (LO).<br />

These current values are valid for 200 V or 240 V.<br />

3) The base-load current I H is based on the duty cycle for high overload (HO).<br />

These current values are valid for 200 V or 240 V.<br />

4) The input current depends on the motor load and line impedance.<br />

The input currents apply for a load at rated power (based on I L ) for a line<br />

impedance corresponding to u K = 1 %. The current values are specified on<br />

the rating plate of the converter.<br />

2/12 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Load-side power components (Configuration with line-side components see double page before)<br />

Output reactors Sine-wave filters dv/dt filters plus VPL<br />

Article No. Article No. Article No.<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

– – –<br />

2<br />

Ordering examples<br />

Basic selection Example 1 Example 2<br />

SINAMICS G120X converters · degree of protection IP20/UL Open Type · 200 ... 240 V 3 AC, 6SL32 ■ 0- ■ YC28- ■ U ■ 0 6SL32 ■ 0- ■ YC28- ■ U ■ 0<br />

15 kW · without integrated line filter<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 2<br />

Class 3C3 3<br />

Operator Panel<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension 0 0<br />

With SINAMICS G120X I/O Extension Module<br />

Line filter<br />

Without integrated line filter U U<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP<br />

PROFINET, EtherNet/IP F F<br />

PROFIBUS DP<br />

Complete Article No. 6SL32 2 0- 3 YC28- 0 U F 0 6SL32 3 0- 2 YC28- 0 U F 0<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/13


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Selection and ordering data<br />

2<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 380 ... 480 V 3 AC ➡ Configuration with line-side components (see right page)<br />

Rated power 1) Rated output current 2) Base-load current<br />

I 3)<br />

H<br />

Rated<br />

input<br />

current 4)<br />

400 V 480 V 400 V 480 V 400 V 480 V 400 V<br />

Frame size SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

without integrated line filter<br />

Converters up to 132 kW<br />

delivery ex stock<br />

10 ...<br />

48<br />

SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

with integrated line filter<br />

Converters up to 132 kW<br />

delivery ex stock<br />

10 ...<br />

48<br />

kW hp A A A A A Article No. Article No. <br />

380 ... 480 V 3 AC · Rated pulse frequency 4 kHz 90 kW and 2 kHz 110 kW · Input frequency 47 ... 63 Hz<br />

0.75 1 2.2 2.1 1.7 1.6 2.1 FSA 6SL32 ■ 0- ■ YE10- ■ U ■ 0 6SL32 ■ 0- ■ YE10- ■ A ■ 0<br />

1.1 1.5 3.1 3 2.2 2.1 2.8 FSA 6SL32 ■ 0- ■ YE12- ■ U ■ 0 6SL32 ■ 0- ■ YE12- ■ A ■ 0<br />

1.5 2 4.1 3.4 3.1 3 3.6 FSA 6SL32 ■ 0- ■ YE14- ■ U ■ 0 6SL32 ■ 0- ■ YE14- ■ A ■ 0<br />

2.2 3 5.9 4.8 4.1 3.4 5.5 FSA 6SL32 ■ 0- ■ YE16- ■ U ■ 0 6SL32 ■ 0- ■ YE16- ■ A ■ 0<br />

3 4 7.7 6.2 5.9 4.8 6.9 FSA 6SL32 ■ 0- ■ YE18- ■ U ■ 0 6SL32 ■ 0- ■ YE18- ■ A ■ 0<br />

4 5 10.2 7.6 7.7 6.2 9.8 FSB 6SL32 ■ 0- ■ YE20- ■ U ■ 0 6SL32 ■ 0- ■ YE20- ■ A ■ 0<br />

5.5 7.5 13.2 11 10.2 7.6 12 FSB 6SL32 ■ 0- ■ YE22- ■ U ■ 0 6SL32 ■ 0- ■ YE22- ■ A ■ 0<br />

7.5 10 18 14 13.2 11 17 FSB 6SL32 ■ 0- ■ YE24- ■ U ■ 0 6SL32 ■ 0- ■ YE24- ■ A ■ 0<br />

11 15 26 21 18 14 24.5 FSC 6SL32 ■ 0- ■ YE26- ■ U ■ 0 6SL32 ■ 0- ■ YE26- ■ A ■ 0<br />

15 20 32 27 26 21 29.5 FSC 6SL32 ■ 0- ■ YE28- ■ U ■ 0 6SL32 ■ 0- ■ YE28- ■ A ■ 0<br />

18.5 25 38 34 32 27 36 FSD 6SL32 ■ 0- ■ YE30- ■ U ■ 0 6SL32 ■ 0- ■ YE30- ■ A ■ 0<br />

22 30 45 40 38 34 42 FSD 6SL32 ■ 0- ■ YE32- ■ U ■ 0 6SL32 ■ 0- ■ YE32- ■ A ■ 0<br />

30 40 60 52 45 40 57 FSD 6SL32 ■ 0- ■ YE34- ■ U ■ 0 6SL32 ■ 0- ■ YE34- ■ A ■ 0<br />

37 50 75 65 60 52 70 FSD 6SL32 ■ 0- ■ YE36- ■ U ■ 0 6SL32 ■ 0- ■ YE36- ■ A ■ 0<br />

45 60 90 77 75 65 86 FSE 6SL32 ■ 0- ■ YE38- ■ U ■ 0 6SL32 ■ 0- ■ YE38- ■ A ■ 0<br />

55 75 110 96 90 77 104 FSE 6SL32 ■ 0- ■ YE40- ■ U ■ 0 6SL32 ■ 0- ■ YE40- ■ A ■ 0<br />

75 100 145 124 110 96 140 FSF 6SL32 ■ 0- ■ YE42- ■ U ■ 0 6SL32 ■ 0- ■ YE42- ■ A ■ 0<br />

90 125 178 156 145 124 172 FSF 6SL32 ■ 0- ■ YE44- ■ U ■ 0 6SL32 ■ 0- ■ YE44- ■ A ■ 0<br />

110 150 205 180 178 156 198 FSF 6SL32 ■ 0- ■ YE46- ■ U ■ 0 6SL32 ■ 0- ■ YE46- ■ A ■ 0<br />

132 200 250 240 205 180 242 FSF 6SL32 ■ 0- ■ YE48- ■ U ■ 0 6SL32 ■ 0- ■ YE48- ■ A ■ 0<br />

160 250 302 302 250 240 301 FSG – 6SL32 ■ 0- ■ YE50- ■ ■ ■ 0<br />

200 300 370 361 302 302 365 FSG – 6SL32 ■ 0- ■ YE52- ■ ■ ■ 0<br />

250 400 477 477 370 361 471 FSG – 6SL32 ■ 0- ■ YE54- ■ ■ ■ 0<br />

315 400 570 477 468 390 585 FSH – 6SL32 2 0- ■ YE56- ■ C ■ 0<br />

355 450 640 515 491 394 654 FSH – 6SL32 2 0- ■ YE58- ■ C ■ 0<br />

400 500 720 590 551 452 735 FSH – 6SL32 2 0- ■ YE60- ■ C ■ 0<br />

450 500 820 663 672 542 850 FSJ – 6SL32 2 0- ■ YE62- ■ C ■ 0<br />

500 600 890 724 728 591 924 FSJ – 6SL32 2 0- ■ YE64- ■ C ■ 0<br />

560 700 1000 830 786 652 1<strong>03</strong>8 FSJ – 6SL32 2 0- ■ YE66- ■ C ■ 0<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 – delivery ex stock 2 2<br />

Class 3C3 * 3 3<br />

Operator Panel<br />

Without Operator Panel * 1 1<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) * 2 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) – delivery ex stock 3 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension – delivery ex stock 0 0<br />

With SINAMICS G120X I/O Extension Module * 1 1<br />

NEW NEU<br />

Line filter<br />

Without integrated line filter – delivery ex stock<br />

U<br />

With integrated line filter Category C2 – delivery ex stock<br />

A<br />

With integrated line filter Category C3 *<br />

C<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP * B B<br />

PROFINET, EtherNet/IP – delivery ex stock F F<br />

PROFIBUS DP * P P<br />

* If you select one of these supplements, the delivery time for converters up to 132 kW will change from "delivery ex stock" to "standard delivery time".<br />

1) Rated power based on the base-load current I L . The base-load current I L<br />

is based on the duty cycle for low overload (LO).<br />

2) The rated output current is based on the duty cycle for low overload (LO).<br />

These current values are valid for 400 V or 480 V.<br />

3) The base-load current I H is based on the duty cycle for high overload (HO).<br />

These current values are valid for 400 V or 480 V.<br />

4) The input current depends on the motor load and line impedance.<br />

The input currents apply for a load at rated power (based on I L ) for a line<br />

impedance corresponding to u K = 1 %. The current values are specified on<br />

the rating plate of the converter.<br />

2/14 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Line-side components (Configuration with load-side power components see next double page)<br />

Line filters<br />

Category C2 Category C1<br />

Line harmonics filters 1)<br />

(THD(I) < 5 %)<br />

Line reactors<br />

For frame sizes<br />

Mandatory for<br />

•FSA to FSF 90 kW:<br />

Converter without integrated<br />

line filter<br />

• FSF 110 kW:<br />

Converter with integrated<br />

line filter<br />

FSH and FSJ<br />

mandatory when using<br />

an external<br />

line filter Category C2<br />

Recommended line-side<br />

overcurrent protection devices 4)<br />

Fuses<br />

IEC-compliant<br />

Fuses<br />

UL/cUL-compliant<br />

Rated voltage<br />

600 V AC 5)<br />

Current Fuse type Current<br />

Article No. Article No. Article No. A Article No. Class/Article No. A<br />

SINAMICS G120X<br />

available with<br />

integrated line filter<br />

Category C2<br />

6SL32<strong>03</strong>-0BE17-7BA1<br />

6)<br />

6SL32<strong>03</strong>-0BE21-8BA0<br />

6)<br />

6SL32<strong>03</strong>-0BE23-8BA0<br />

6)<br />

– A DC line reactor 16 3NA3805 J 15<br />

– is integrated for 16 3NA3805 J 15<br />

frame sizes<br />

–<br />

FSA to FSG –<br />

16 3NA3805 J 15<br />

– therefore no<br />

16 3NA3805 J 15<br />

– line reactor<br />

16 3NA3805 J 15<br />

is required.<br />

– 32 3NA3812 J 35<br />

UAC:FN34406112E2XXJRX 32 3NA3812 J 35<br />

UAC:FN344<strong>08</strong>112E2XXJRX 32 3NA3812 J 35<br />

UAC:FN344011113E2FAJRX 50 3NA3820 J 50<br />

UAC:FN344015113E2FAJRX 50 3NA3820 J 50<br />

6SL32<strong>03</strong>-0BE23-8BA0 UAC:FN344019113E2FAJRX 63 3NA3822 J 60<br />

UAC:FN344022115E2FAJRX 80 3NA3824 J 70<br />

6SL32<strong>03</strong>-0BE27-5BA0 UAC:FN344<strong>03</strong>0115E2FAJRX 100 3NA3830 J 90<br />

UAC:FN344<strong>03</strong>7115E2FAJRX 100 3NA3830 J 100<br />

6SL32<strong>03</strong>-0BE31-1BA0 UAC:FN344045115E2FAJRX 125 3NA3832 J 125<br />

UAC:FN344055115E2FAJRX 160 3NA3836 J 150<br />

6SL3000-0BE31-2DA0 UAC:FN344075116E2FAJRX 200 3NA3140 J 200<br />

UAC:FN344090116E2FAJRX 224 3NA3142 J 250<br />

6SL32<strong>03</strong>-0BE31-8BA0 UAC:FN3440110118E2FAJRX 300 3NA3250 J 300<br />

– UAC:FN3440132118E2FAJXX 315 3NA3252 J 350<br />

– UAC:FN3440160118E2FAJXX 2) 355 3NA3254 J 400<br />

– UAC:FN3440200118E2FAJXX 2) 400 3NA3260 J 500<br />

– UAC:FN3440132118E2FAJXX (2×) 2) 3) 630 3NA3372 J 600<br />

6SL3760-0MR00-0AA0 – – 6SL3000-0CE36-3AA0 710 3NE1437-2 710<br />

– – 6SL3000-0CE37-7AA0 800 3NE1438-2 800<br />

– – 850 3NE1448-2 850<br />

– – 6SL3000-0CE38-7AA0 1000 3NB3350-1KK26 1000<br />

– – 6SL3000-0CE41-0AA0 1100 3NB3351-1KK26 1100<br />

– – 1250 3NB3352-1KK26 1250<br />

2<br />

1) Voltage 380 V to 415 V, frequency 50 Hz.<br />

2) For 160 kW, 200 kW and 250 kW, only operation in Vector Control is<br />

permitted. V/f must not be used.<br />

3) 250 kW with parallel connection of 2x 132 kW.<br />

4) Further information at<br />

https://support.industry.siemens.com/cs/document/109762895<br />

5) The Short Circuit Current Rating (SCCR) according to UL for industrial <strong>control</strong><br />

panel installations to NEC Article 409 or UL 5<strong>08</strong>A/5<strong>08</strong>C or UL 61800-5-1<br />

is 100 kA for SINAMICS G120X.<br />

6) The line filters are suitable for base mounting for SINAMICS G120X frame<br />

sizes FSA to FSC. Further information especially to achieve EMC Category<br />

C1 is available in the documentation on the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/15


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Selection and ordering data<br />

2<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 380 ... 480 V 3 AC ➡ Configuration with load-side power components (see right page)<br />

Rated power 1) Rated output current 2) Base-load current<br />

I 3)<br />

H<br />

Rated<br />

input<br />

current 4)<br />

Frame size SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

without integrated line filter<br />

Converters up to 132 kW<br />

delivery ex stock<br />

SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

with integrated line filter<br />

Converters up to 132 kW<br />

delivery ex stock<br />

400 V 480 V 400 V 480 V 400 V 480 V 400 V<br />

10 ...<br />

48<br />

10 ...<br />

48<br />

kW hp A A A A A Article No. Article No. <br />

380 ... 480 V 3 AC · Rated pulse frequency 4 kHz 90 kW and 2 kHz 110 kW · Input frequency 47 ... 63 Hz<br />

0.75 1 2.2 2.1 1.7 1.6 2.1 FSA 6SL32 ■ 0- ■ YE10- ■ U ■ 0 6SL32 ■ 0- ■ YE10- ■ A ■ 0<br />

1.1 1.5 3.1 3 2.2 2.1 2.8 FSA 6SL32 ■ 0- ■ YE12- ■ U ■ 0 6SL32 ■ 0- ■ YE12- ■ A ■ 0<br />

1.5 2 4.1 3.4 3.1 3 3.6 FSA 6SL32 ■ 0- ■ YE14- ■ U ■ 0 6SL32 ■ 0- ■ YE14- ■ A ■ 0<br />

2.2 3 5.9 4.8 4.1 3.4 5.5 FSA 6SL32 ■ 0- ■ YE16- ■ U ■ 0 6SL32 ■ 0- ■ YE16- ■ A ■ 0<br />

3 4 7.7 6.2 5.9 4.8 6.9 FSA 6SL32 ■ 0- ■ YE18- ■ U ■ 0 6SL32 ■ 0- ■ YE18- ■ A ■ 0<br />

4 5 10.2 7.6 7.7 6.2 9.8 FSB 6SL32 ■ 0- ■ YE20- ■ U ■ 0 6SL32 ■ 0- ■ YE20- ■ A ■ 0<br />

5.5 7.5 13.2 11 10.2 7.6 12 FSB 6SL32 ■ 0- ■ YE22- ■ U ■ 0 6SL32 ■ 0- ■ YE22- ■ A ■ 0<br />

7.5 10 18 14 13.2 11 17 FSB 6SL32 ■ 0- ■ YE24- ■ U ■ 0 6SL32 ■ 0- ■ YE24- ■ A ■ 0<br />

11 15 26 21 18 14 24.5 FSC 6SL32 ■ 0- ■ YE26- ■ U ■ 0 6SL32 ■ 0- ■ YE26- ■ A ■ 0<br />

15 20 32 27 26 21 29.5 FSC 6SL32 ■ 0- ■ YE28- ■ U ■ 0 6SL32 ■ 0- ■ YE28- ■ A ■ 0<br />

18.5 25 38 34 32 27 36 FSD 6SL32 ■ 0- ■ YE30- ■ U ■ 0 6SL32 ■ 0- ■ YE30- ■ A ■ 0<br />

22 30 45 40 38 34 42 FSD 6SL32 ■ 0- ■ YE32- ■ U ■ 0 6SL32 ■ 0- ■ YE32- ■ A ■ 0<br />

30 40 60 52 45 40 57 FSD 6SL32 ■ 0- ■ YE34- ■ U ■ 0 6SL32 ■ 0- ■ YE34- ■ A ■ 0<br />

37 50 75 65 60 52 70 FSD 6SL32 ■ 0- ■ YE36- ■ U ■ 0 6SL32 ■ 0- ■ YE36- ■ A ■ 0<br />

45 60 90 77 75 65 86 FSE 6SL32 ■ 0- ■ YE38- ■ U ■ 0 6SL32 ■ 0- ■ YE38- ■ A ■ 0<br />

55 75 110 96 90 77 104 FSE 6SL32 ■ 0- ■ YE40- ■ U ■ 0 6SL32 ■ 0- ■ YE40- ■ A ■ 0<br />

75 100 145 124 110 96 140 FSF 6SL32 ■ 0- ■ YE42- ■ U ■ 0 6SL32 ■ 0- ■ YE42- ■ A ■ 0<br />

90 125 178 156 145 124 172 FSF 6SL32 ■ 0- ■ YE44- ■ U ■ 0 6SL32 ■ 0- ■ YE44- ■ A ■ 0<br />

110 150 205 180 178 156 198 FSF 6SL32 ■ 0- ■ YE46- ■ U ■ 0 6SL32 ■ 0- ■ YE46- ■ A ■ 0<br />

132 200 250 240 205 180 242 FSF 6SL32 ■ 0- ■ YE48- ■ U ■ 0 6SL32 ■ 0- ■ YE48- ■ A ■ 0<br />

160 250 302 302 250 240 301 FSG – 6SL32 ■ 0- ■ YE50- ■ ■ ■ 0<br />

200 300 370 361 302 302 365 FSG – 6SL32 ■ 0- ■ YE52- ■ ■ ■ 0<br />

250 400 477 477 370 361 471 FSG – 6SL32 ■ 0- ■ YE54- ■ ■ ■ 0<br />

315 400 570 477 468 390 585 FSH – 6SL32 2 0- ■ YE56- ■ C ■ 0<br />

355 450 640 515 491 394 654 FSH – 6SL32 2 0- ■ YE58- ■ C ■ 0<br />

400 500 720 590 551 452 735 FSH – 6SL32 2 0- ■ YE60- ■ C ■ 0<br />

450 500 820 663 672 542 850 FSJ – 6SL32 2 0- ■ YE62- ■ C ■ 0<br />

500 600 890 724 728 591 924 FSJ – 6SL32 2 0- ■ YE64- ■ C ■ 0<br />

560 700 1000 830 786 652 1<strong>03</strong>8 FSJ – 6SL32 2 0- ■ YE66- ■ C ■ 0<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 – delivery ex stock 2 2<br />

Class 3C3 * 3 3<br />

Operator Panel<br />

Without Operator Panel * 1 1<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) * 2 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) – delivery ex stock 3 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension – delivery ex stock 0 0<br />

With SINAMICS G120X I/O Extension Module * 1 1<br />

NEW NEU<br />

Line filter<br />

Without integrated line filter – delivery ex stock<br />

U<br />

With integrated line filter Category C2 – delivery ex stock<br />

A<br />

With integrated line filter Category C3 *<br />

C<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP * B B<br />

PROFINET, EtherNet/IP – delivery ex stock F F<br />

PROFIBUS DP * P P<br />

* If you select one of these supplements, the delivery time for converters up to 132 kW will change from "delivery ex stock" to "standard delivery time".<br />

1) Rated power based on the base-load current I L . The base-load current I L<br />

is based on the duty cycle for low overload (LO).<br />

2) The rated output current is based on the duty cycle for low overload (LO).<br />

These current values are valid for 400 V or 480 V.<br />

3) The base-load current I H is based on the duty cycle for high overload (HO).<br />

These current values are valid for 400 V or 480 V.<br />

4) The input current depends on the motor load and line impedance.<br />

The input currents apply for a load at rated power (based on I L ) for a line<br />

impedance corresponding to u K = 1 %. The current values are specified on<br />

the rating plate of the converter.<br />

2/16 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Load-side power components (Configuration with line-side components see double page before)<br />

Output reactors<br />

Sine-wave filters<br />

When using sine-wave filters,<br />

please note for the pulse<br />

frequency of the converter:<br />

• 90 kW: 4 kHz up to 8 kHz<br />

• 110 kW: 4 kHz<br />

dv/dt filters plus VPL<br />

Article No. Article No. Article No.<br />

– 6SL3202-0AE20-3SA0 –<br />

– 6SL3202-0AE20-6SA0 –<br />

– –<br />

– 6SL3202-0AE21-1SA0 –<br />

– –<br />

– 6SL3202-0AE21-4SA0 –<br />

– 6SL3202-0AE22-0SA0 –<br />

– –<br />

– 6SL3202-0AE23-3SA0 –<br />

– –<br />

6SL3202-0AE23-8CA0 6SL3202-0AE24-6SA0 JTA:TEF12<strong>03</strong>-0HB<br />

6SE6400-3TC07-5ED0<br />

JTA:TEF12<strong>03</strong>-0JB<br />

6SL3202-0AE26-2SA0<br />

6SL3202-0AE28-8SA0 JTA:TEF12<strong>03</strong>-0KB<br />

6SE6400-3TC14-5FD0<br />

6SL3202-0AE31-5SA0 JTA:TEF12<strong>03</strong>-0LB<br />

2<br />

6SL3202-0AE31-8SA0 JTA:TEF12<strong>03</strong>-0MB<br />

6SL3000-2BE32-1AA0 6SL3000-2CE32-3AA0 1)<br />

6SL3000-2BE32-6AA0<br />

6SL3000-2BE33-2AA0 6SL3000-2CE32-8AA0 1) 2) 6SL3000-2DE35-0AA0<br />

6SL3000-2BE33-8AA0 6SL3000-2CE33-3AA0 1) 2)<br />

6SL3000-2BE35-0AA0 6SL3000-2CE34-1AA0 1) 2)<br />

6SL3000-2AE36-1AA0 – 6SL3000-2DE38-4AA0<br />

6SL3000-2AE38-4AA0 –<br />

–<br />

6SL3000-2AE41-0AA0 – 6SL3000-2DE41-4AA0<br />

–<br />

6SL3000-2AE41-4AA0 –<br />

Ordering examples<br />

Basic selection Example 1 Example 2<br />

SINAMICS G120X converters · degree of protection IP20/UL Open Type · 380 ... 480 V 3 AC, 6SL32 ■ 0- ■ YE28- ■ A ■ 0 6SL32 ■ 0- ■ YE28- ■ A ■ 0<br />

15 kW · with integrated line filter – converters up to 132 kW delivery ex stock<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 – delivery ex stock 2<br />

Class 3C3 * 3<br />

Operator Panel<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) * 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) – delivery ex stock 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension – delivery ex stock 0 0<br />

With SINAMICS G120X I/O Extension Module *<br />

Line filter<br />

With integrated line filter Category C2 – delivery ex stock A A<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP *<br />

PROFINET, EtherNet/IP – delivery ex stock F F<br />

PROFIBUS DP *<br />

Complete Article No. 6SL32 2 0- 3 YE28- 0 A F 0 6SL32 3 0- 2 YE28- 0 A F 0<br />

Delivery ex stock<br />

Standard delivery time<br />

* If you select one of these supplements, the delivery time for converters up to 132 kW will change from "delivery ex stock" to "standard delivery time".<br />

1) For converters with a rated power 110 kW, around 70 % of the current<br />

and power is still available when using sine-wave filters due to current<br />

derating of the converter.<br />

2) For 160 kW, 200 kW and 250 kW, only operation in Vector Control is<br />

permitted. V/f must not be used.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/17


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Selection and ordering data<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 500 ... 690 V 3 AC ➡ Configuration with line-side components (see right page)<br />

Rated power 1) Rated output current 2) Base-load current<br />

I 3)<br />

H<br />

Rated<br />

input<br />

current 4)<br />

Frame size SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

without integrated<br />

line filter<br />

SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

with integrated<br />

line filter<br />

2<br />

690 V 600 V 690 V 600 V 690 V 600 V 690 V<br />

kW hp A A A A A Article No. Article No.<br />

500 ... 690 V 3 AC · Rated pulse frequency 2 kHz · Input frequency 47 ... 63 Hz<br />

3 4 5 5 4 4 6 FSD 6SL32 ■ 0- ■ YH18- ■ U ■ 0 6SL32 ■ 0- ■ YH18- ■ A ■ 0<br />

4 5 6.3 6.3 5 5 7 FSD 6SL32 ■ 0- ■ YH20- ■ U ■ 0 6SL32 ■ 0- ■ YH20- ■ A ■ 0<br />

5.5 7.5 9 9 6.3 6.3 10 FSD 6SL32 ■ 0- ■ YH22- ■ U ■ 0 6SL32 ■ 0- ■ YH22- ■ A ■ 0<br />

7.5 10 11 11 9 9 12 FSD 6SL32 ■ 0- ■ YH24- ■ U ■ 0 6SL32 ■ 0- ■ YH24- ■ A ■ 0<br />

11 10 14 14 11 11 15 FSD 6SL32 ■ 0- ■ YH26- ■ U ■ 0 6SL32 ■ 0- ■ YH26- ■ A ■ 0<br />

15 15 19 19 14 14 19 FSD 6SL32 ■ 0- ■ YH28- ■ U ■ 0 6SL32 ■ 0- ■ YH28- ■ A ■ 0<br />

18.5 20 23 23 19 19 23 FSD 6SL32 ■ 0- ■ YH30- ■ U ■ 0 6SL32 ■ 0- ■ YH30- ■ A ■ 0<br />

22 25 27 27 23 23 26 FSD 6SL32 ■ 0- ■ YH32- ■ U ■ 0 6SL32 ■ 0- ■ YH32- ■ A ■ 0<br />

30 30 35 35 27 27 34 FSD 6SL32 ■ 0- ■ YH34- ■ U ■ 0 6SL32 ■ 0- ■ YH34- ■ A ■ 0<br />

37 40 42 42 35 35 41 FSD 6SL32 ■ 0- ■ YH36- ■ U ■ 0 6SL32 ■ 0- ■ YH36- ■ A ■ 0<br />

45 50 52 52 42 42 52 FSE 6SL32 ■ 0- ■ YH38- ■ U ■ 0 6SL32 ■ 0- ■ YH38- ■ A ■ 0<br />

55 60 62 62 52 52 60 FSE 6SL32 ■ 0- ■ YH40- ■ U ■ 0 6SL32 ■ 0- ■ YH40- ■ A ■ 0<br />

75 75 80 80 62 62 80 FSF 6SL32 ■ 0- ■ YH42- ■ U ■ 0 6SL32 ■ 0- ■ YH42- ■ C ■ 0<br />

90 100 100 100 80 80 99 FSF 6SL32 ■ 0- ■ YH44- ■ U ■ 0 6SL32 ■ 0- ■ YH44- ■ C ■ 0<br />

110 125 125 125 100 100 124 FSF 6SL32 ■ 0- ■ YH46- ■ U ■ 0 6SL32 ■ 0- ■ YH46- ■ C ■ 0<br />

132 150 144 144 125 125 141 FSF 6SL32 ■ 0- ■ YH48- ■ U ■ 0 6SL32 ■ 0- ■ YH48- ■ C ■ 0<br />

160 150 171 171 144 144 175 FSG 5) – 6SL32 ■ 0- ■ YH50- ■ C ■ 0<br />

200 200 2<strong>08</strong> 2<strong>08</strong> 171 171 210 FSG 5) – 6SL32 ■ 0- ■ YH52- ■ C ■ 0<br />

250 250 250 250 2<strong>08</strong> 2<strong>08</strong> 255 FSG 5) – 6SL32 ■ 0- ■ YH54- ■ C ■ 0<br />

315 350 330 345 272 282 343 FSH – 6SL32 2 0- ■ YH56- ■ C ■ 0<br />

355 400 385 388 314 317 401 FSH – 6SL32 2 0- ■ YH58- ■ C ■ 0<br />

400 450 420 432 348 357 437 FSH – 6SL32 2 0- ■ YH60- ■ C ■ 0<br />

450 500 470 487 394 4<strong>08</strong> 489 FSH – 6SL32 2 0- ■ YH62- ■ C ■ 0<br />

500 500 520 546 444 462 540 FSJ – 6SL32 2 0- ■ YH64- ■ C ■ 0<br />

560 600 580 610 476 498 602 FSJ – 6SL32 2 0- ■ YH66- ■ C ■ 0<br />

630 700 650 679 532 554 675 FSJ – 6SL32 2 0- ■ YH68- ■ C ■ 0<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 2 2<br />

Class 3C3 3 3<br />

Operator Panel<br />

Without Operator Panel 1 1<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) 2 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) 3 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension 0 0<br />

With SINAMICS G120X I/O Extension Module 1 1<br />

NEW NEU<br />

Line filter<br />

Without integrated line filter<br />

U<br />

With integrated line filter Category C2<br />

A<br />

With integrated line filter Category C3<br />

C<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP B B<br />

PROFINET, EtherNet/IP F F<br />

PROFIBUS DP P P<br />

1) Rated power based on the base-load current I L . The base-load current I L<br />

is based on the duty cycle for low overload (LO).<br />

2) The rated output current is based on the duty cycle for low overload (LO).<br />

These current values are valid for 690 V or 600 V.<br />

3) The base-load current I H is based on the duty cycle for high overload (HO).<br />

These current values are valid for 690 V or 600 V.<br />

4) The input current depends on the motor load and line impedance.<br />

The input currents apply for a load at rated power (based on I L ) for a line<br />

impedance corresponding to u K = 1 %. The current values are specified on<br />

the rating plate of the converter.<br />

5) The 690 V versions of frame size FSG are only available with an integrated<br />

line filter Category C3. To operate the converters also within TN systems<br />

with grounded outer conductor, you must remove the grounding screw.<br />

2/18 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Line-side components (Configuration with load-side power components see next double page)<br />

Line filters Line reactors Recommended line-side overcurrent protection devices 1)<br />

Category C2 Category C1 For frame sizes FSH and FSJ<br />

mandatory when using an<br />

external line filter Category C2<br />

Fuses<br />

IEC-compliant<br />

Fuses<br />

UL/cUL-compliant<br />

Rated voltage<br />

600 V AC 2)<br />

Current Fuse type Current<br />

Article No. Article No. A Article No. Class/Article No. A<br />

SINAMICS G120X<br />

– A DC link reactor<br />

16 3NA3805-6 J 8<br />

available with<br />

– is integrated for<br />

16 3NA3805-6 J 10<br />

integrated line filter<br />

frame sizes<br />

Category C2<br />

–<br />

FSA to FSG –<br />

16 3NA3805-6 J 15<br />

– therefore no<br />

16 3NA3805-6 J 15<br />

– line reactor<br />

20 3NA3807-6 J 20<br />

is required.<br />

– 25 3NA3810-6 J 25<br />

– 32 3NA3812-6 J 30<br />

– 40 3NA3817-6KJ J 35<br />

– 50 3NA3820-6KJ J 50<br />

– 63 3NA3822-6 J 60<br />

– 80 3NA3824-6 J 80<br />

– 80 3NA3824-6 J 80<br />

– – 100 3NA3830-6 J 110<br />

– – 125 3NA3132-6 J 150<br />

– – 160 3NA3136-6 J 150<br />

– – 200 3NA3140-6 J 200<br />

– – 250 3NE1227-0 250<br />

– – 315 3NE1230-0 315<br />

– – 350 3NE1331-0 350<br />

6SL3760-0MS00-0AA0 – 6SL3000-0CH34-8AA0 450 3NE1333-2 450<br />

– 500 3NE1334-2 500<br />

– 560 3NE1435-2 560<br />

– 6SL3000-0CH36-0AA0 630 3NE1436-2 630<br />

– 710 3NE1437-2 710<br />

– 6SL3000-0CH38-4AA0 800 3NE1438-2 800<br />

– 850 3NE1448-2 850<br />

2<br />

1) Further information at<br />

https://support.industry.siemens.com/cs/document/109762895<br />

2) The Short Circuit Current Rating (SCCR) according to UL for industrial <strong>control</strong><br />

panel installations to NEC Article 409 or UL 5<strong>08</strong>A/5<strong>08</strong>C or UL 61800-5-1<br />

is 100 kA for SINAMICS G120X.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/19


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Selection and ordering data<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 500 ... 690 V 3 AC ➡ Configuration with load-side power components (see right page)<br />

Rated power 1) Rated output current 2) Base-load current<br />

I 3)<br />

H<br />

Rated<br />

input<br />

current 4)<br />

Frame size SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

without integrated<br />

line filter<br />

SINAMICS G120X<br />

Degree of protection<br />

IP20/UL Open Type<br />

with integrated<br />

line filter<br />

2<br />

690 V 600 V 690 V 600 V 690 V 600 V 690 V<br />

kW hp A A A A A Article No. Article No.<br />

500 ... 690 V 3 AC · Rated pulse frequency 2 kHz · Input frequency 47 ... 63 Hz<br />

3 4 5 5 4 4 6 FSD 6SL32 ■ 0- ■ YH18- ■ U ■ 0 6SL32 ■ 0- ■ YH18- ■ A ■ 0<br />

4 5 6.3 6.3 5 5 7 FSD 6SL32 ■ 0- ■ YH20- ■ U ■ 0 6SL32 ■ 0- ■ YH20- ■ A ■ 0<br />

5.5 7.5 9 9 6.3 6.3 10 FSD 6SL32 ■ 0- ■ YH22- ■ U ■ 0 6SL32 ■ 0- ■ YH22- ■ A ■ 0<br />

7.5 10 11 11 9 9 12 FSD 6SL32 ■ 0- ■ YH24- ■ U ■ 0 6SL32 ■ 0- ■ YH24- ■ A ■ 0<br />

11 10 14 14 11 11 15 FSD 6SL32 ■ 0- ■ YH26- ■ U ■ 0 6SL32 ■ 0- ■ YH26- ■ A ■ 0<br />

15 15 19 19 14 14 19 FSD 6SL32 ■ 0- ■ YH28- ■ U ■ 0 6SL32 ■ 0- ■ YH28- ■ A ■ 0<br />

18.5 20 23 23 19 19 23 FSD 6SL32 ■ 0- ■ YH30- ■ U ■ 0 6SL32 ■ 0- ■ YH30- ■ A ■ 0<br />

22 25 27 27 23 23 26 FSD 6SL32 ■ 0- ■ YH32- ■ U ■ 0 6SL32 ■ 0- ■ YH32- ■ A ■ 0<br />

30 30 35 35 27 27 34 FSD 6SL32 ■ 0- ■ YH34- ■ U ■ 0 6SL32 ■ 0- ■ YH34- ■ A ■ 0<br />

37 40 42 42 35 35 41 FSD 6SL32 ■ 0- ■ YH36- ■ U ■ 0 6SL32 ■ 0- ■ YH36- ■ A ■ 0<br />

45 50 52 52 42 42 52 FSE 6SL32 ■ 0- ■ YH38- ■ U ■ 0 6SL32 ■ 0- ■ YH38- ■ A ■ 0<br />

55 60 62 62 52 52 60 FSE 6SL32 ■ 0- ■ YH40- ■ U ■ 0 6SL32 ■ 0- ■ YH40- ■ A ■ 0<br />

75 75 80 80 62 62 80 FSF 6SL32 ■ 0- ■ YH42- ■ U ■ 0 6SL32 ■ 0- ■ YH42- ■ C ■ 0<br />

90 100 100 100 80 80 99 FSF 6SL32 ■ 0- ■ YH44- ■ U ■ 0 6SL32 ■ 0- ■ YH44- ■ C ■ 0<br />

110 125 125 125 100 100 124 FSF 6SL32 ■ 0- ■ YH46- ■ U ■ 0 6SL32 ■ 0- ■ YH46- ■ C ■ 0<br />

132 150 144 144 125 125 141 FSF 6SL32 ■ 0- ■ YH48- ■ U ■ 0 6SL32 ■ 0- ■ YH48- ■ C ■ 0<br />

160 150 171 171 144 144 175 FSG 5) – 6SL32 ■ 0- ■ YH50- ■ C ■ 0<br />

200 200 2<strong>08</strong> 2<strong>08</strong> 171 171 210 FSG 5) – 6SL32 ■ 0- ■ YH52- ■ C ■ 0<br />

250 250 250 250 2<strong>08</strong> 2<strong>08</strong> 255 FSG 5) – 6SL32 ■ 0- ■ YH54- ■ C ■ 0<br />

315 350 330 345 272 282 343 FSH – 6SL32 2 0- ■ YH56- ■ C ■ 0<br />

355 400 385 388 314 317 401 FSH – 6SL32 2 0- ■ YH58- ■ C ■ 0<br />

400 450 420 432 348 357 437 FSH – 6SL32 2 0- ■ YH60- ■ C ■ 0<br />

450 500 470 487 394 4<strong>08</strong> 489 FSH – 6SL32 2 0- ■ YH62- ■ C ■ 0<br />

500 500 520 546 444 462 540 FSJ – 6SL32 2 0- ■ YH64- ■ C ■ 0<br />

560 600 580 610 476 498 602 FSJ – 6SL32 2 0- ■ YH66- ■ C ■ 0<br />

630 700 650 679 532 554 675 FSJ – 6SL32 2 0- ■ YH68- ■ C ■ 0<br />

Article No. supplements<br />

Environmental class/harmful chemical substances acc. to IEC 60721-3-3: 2002<br />

Class 3C2 2 2<br />

Class 3C3 3 3<br />

Operator Panel<br />

Without Operator Panel 1 1<br />

With BOP-2 Basic Operator Panel (numeric 2-line display) 2 2<br />

With IOP-2 Intelligent Operator Panel (graphic color display) 3 3<br />

Extension with SINAMICS G120X I/O Extension Module<br />

Without extension 0 0<br />

With SINAMICS G120X I/O Extension Module 1 1<br />

NEW NEU<br />

Line filter<br />

Without integrated line filter<br />

U<br />

With integrated line filter Category C2<br />

A<br />

With integrated line filter Category C3<br />

C<br />

Communication<br />

USS, Modbus RTU, BACnet MS/TP B B<br />

PROFINET, EtherNet/IP F F<br />

PROFIBUS DP P P<br />

1) Rated power based on the base-load current I L . The base-load current I L<br />

is based on the duty cycle for low overload (LO).<br />

2) The rated output current is based on the duty cycle for low overload (LO).<br />

These current values are valid for 690 V or 600 V.<br />

3) The base-load current I H is based on the duty cycle for high overload (HO).<br />

These current values are valid for 690 V or 600 V.<br />

4) The input current depends on the motor load and line impedance.<br />

The input currents apply for a load at rated power (based on I L ) for a line<br />

impedance corresponding to u K = 1 %. The current values are specified on<br />

the rating plate of the converter.<br />

5) The 690 V versions of frame size FSG are only available with an integrated<br />

line filter Category C3. To operate the converters also within TN systems<br />

with grounded outer conductor, you must remove the grounding screw.<br />

2/20 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

Load-side power components (Configuration with line-side components see double page before)<br />

Output reactors Sine-wave filters dv/dt filters plus VPL<br />

Article No. Article No. Article No.<br />

JTA:TEU2532-0FP00-4EA0 – JTA:TEF12<strong>03</strong>-0GB<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

JTA:TEU9932-0FP00-4EA0 – JTA:TEF12<strong>03</strong>-0HB<br />

–<br />

–<br />

JTA:TEU9932-0FS00-0EA0 – JTA:TEF12<strong>03</strong>-0JB<br />

–<br />

JTA:TEU9932-1FC00-1BA0 – JTA:TEF12<strong>03</strong>-0KB<br />

–<br />

JTA:TEU9932-0FV00-1BA0 – JTA:TEF12<strong>03</strong>-0LB<br />

–<br />

JTA:TEU4732-0FA00-0BA0 – JTA:TEF12<strong>03</strong>-0MB<br />

–<br />

–<br />

6SL3000-2AH34-7AA0 – 6SL3000-2DH35-8AA0<br />

–<br />

6SL3000-2AH35-8AA0 –<br />

6SL3000-2AH38-1AA0 – 6SL3000-2DH38-1AA0<br />

–<br />

–<br />

–<br />

2<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/21


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Clicking to the Industry Mall<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Selection and ordering data<br />

Supplementary system components for SINAMICS G120X<br />

Description<br />

IOP-2 Intelligent Operator Panel<br />

Operating languages: <strong>English</strong>, German,<br />

French, Italian, Spanish, Portuguese,<br />

Dutch, Swedish, Finnish, Russian, Czech,<br />

Polish, Turkish, Chinese Simplified<br />

IOP-2 Handheld<br />

BOP-2 Basic Operator Panel<br />

Door mounting kit<br />

for IOP-2/BOP-2<br />

SINAMICS SD card<br />

512 MB, empty<br />

SINAMICS G120 Smart Access<br />

for wireless commissioning, operation and<br />

diagnostics of the following converters<br />

using a smartphone, tablet or laptop<br />

SINAMICS CONNECT 300 IoT Gateway<br />

for connecting up to eight converters to the<br />

Cloud MindSphere<br />

SINAMICS G120X I/O Extension Module<br />

for direct connection of Pt1000/Ni1000<br />

temperature sensors 1)<br />

Shield connection kits for Power Module<br />

for SINAMICS G120X<br />

• Frame sizes FSA to FSG<br />

• Frame sizes FSH to FSJ<br />

Push-through mounting frames<br />

for SINAMICS G120X<br />

• Frame size FSA<br />

• Frame size FSB<br />

• Frame size FSC<br />

• Frame size FSD<br />

• Frame size FSE<br />

• Frame size FSF<br />

• Frame size FSG<br />

Installation handles<br />

for SINAMICS G120X<br />

• Frame sizes FSD to FSF<br />

IP21 top covers<br />

for SINAMICS G120X<br />

• Frame size FSA<br />

• Frame size FSB<br />

• Frame sizes FSC and FSD<br />

• Frame size FSE<br />

• Frame sizes FSF and FSG<br />

Wiring adapter<br />

for optimal and space-saving wiring<br />

for SINAMICS G120X<br />

• Frame size FSG<br />

Installation kit for line-side<br />

cable connection, left<br />

for SINAMICS G120X<br />

• Frame size FSH<br />

NEW NEU<br />

NEW NEU<br />

NEW NEU<br />

SINAMICS G120X Starter Kits<br />

Converter (380 ... 480 V 3 AC, PROFINET)<br />

with IOP-2 and SINAMICS G120 Smart Access<br />

• 0.75 kW, FSA, without integrated line filter<br />

• 0.75 kW, FSA, with integrated line filter<br />

Category C2<br />

• 3 kW, FSA, with integrated line filter<br />

Category C2<br />

• 7.5 kW, FSB, with integrated line filter<br />

Category C2<br />

SINAMICS G120X training case<br />

Article No.<br />

6SL3255-0AA00-4JA2<br />

6SL3255-0AA00-4HA1<br />

6SL3255-0AA00-4CA1<br />

6SL3256-0AP00-0JA0<br />

6SL3054-4AG00-2AA0<br />

6SL3255-0AA00-5AA0<br />

6SL3255-0AG30-0AA0<br />

6SL3255-0BE00-0AA0<br />

Included in the scope<br />

of delivery of the<br />

converters, can be<br />

ordered as spare part<br />

Please observe the notes<br />

included in the operating<br />

instructions<br />

6SL3261-6GA00-0BA0<br />

6SL3261-6GB00-0BA0<br />

6SL3261-6GC00-0BA0<br />

6SL3261-6GD00-0BA0<br />

6SL3261-6GE00-0BA0<br />

6SL3261-6GF00-0BA0<br />

6SL3261-6GG00-0BA0<br />

6SL3200-0SM22-0AA0<br />

6SL3266-1PA00-0BA0<br />

6SL3266-1PB00-0BA0<br />

6SL3266-1PD00-0BA0<br />

6SL3266-1PE00-0BA0<br />

6SL3266-1PF00-0BA0<br />

6SL3266-2HG00-0BA0<br />

6SL3366-1LH00-0PA0<br />

6SL3200-0AE70-0AA0<br />

6SL3200-0AE72-0AA0<br />

6SL3200-0AE73-0AA0<br />

6SL3200-0AE74-0AA0<br />

6AG1067-2AA00-0AC1<br />

1) The SINAMICS G120X I/O Extension Module<br />

(article number: 6SL3255-0BE00-0AA0) is only supported on the<br />

SINAMICS G120X converters with FS code ³ 02 02 (FSA to FSG) /<br />

02 (FSH/FSJ) and firmware V1.01.<br />

The FS code version of the converter is on the rating plate.<br />

For more information please refer to the documentation on the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

Spare parts for SINAMICS G120X<br />

Description<br />

FPI board<br />

(freely-programmable interface board)<br />

for SINAMICS G120X<br />

• Frame sizes FSH and FSJ<br />

PSB board (power supply board)<br />

for SINAMICS G120X<br />

• Frame sizes FSH and FSJ<br />

Current transformers<br />

for SINAMICS G120X<br />

• 2000 A for frame size FSJ<br />

• 1000 A for frame sizes FSH and FSJ<br />

Spare parts kit for Control Unit<br />

for SINAMICS G120X<br />

• Frame sizes FSA to FSJ<br />

Shield connection kit for Control Unit<br />

for SINAMICS G120X<br />

• Frame sizes FSD to FSG<br />

Shield connection kits for Power Module<br />

for SINAMICS G120X<br />

• Frame size FSA<br />

• Frame size FSB<br />

• Frame size FSC<br />

• Frame size FSD<br />

• Frame size FSE<br />

• Frame size FSF<br />

• Frame size FSG<br />

Small parts assembly set<br />

for SINAMICS G120X<br />

• Frame sizes FSD to FSG<br />

Terminal cover kits<br />

for SINAMICS G120X<br />

• Frame size FSD<br />

• Frame size FSE<br />

• Frame size FSF<br />

• Frame size FSG<br />

External fan units<br />

for SINAMICS G120X<br />

• Frame size FSA<br />

• Frame size FSB<br />

• Frame size FSC<br />

• Frame size FSD<br />

• Frame size FSE<br />

• Frame size FSF<br />

• Frame size FSG<br />

• Frame sizes FSH and FSJ<br />

Internal fan unit<br />

for SINAMICS G120X<br />

• Frame sizes FSH and FSJ<br />

Control Units<br />

for SINAMICS G120X<br />

frame sizes FSD to FSJ<br />

• USS, Modbus RTU, BACnet MS/TP<br />

• PROFINET, EtherNet/IP<br />

•PROFIBUS DP<br />

Article No.<br />

6SL3200-0SP05-0AA0<br />

6SL3200-0SP06-0AA0<br />

6SL3200-0SE01-0AA0<br />

6SL3200-0SE02-0AA0<br />

6SL3200-0SK10-0AA0<br />

6SL3264-1EA00-0YA0<br />

6SL3262-1AA01-0DA0<br />

6SL3262-1AB01-0DA0<br />

6SL3262-1AC01-0DA0<br />

6SL3262-1AD01-0DA0<br />

6SL3262-1AE01-0DA0<br />

6SL3262-1AF01-0DA0<br />

6SL3262-1AG01-0DA0<br />

6SL3200-0SK<strong>08</strong>-0AA0<br />

6SL3200-0SM13-0AA0<br />

6SL3200-0SM14-0AA0<br />

6SL3200-0SM15-0AA0<br />

6SL3200-0SM16-0AA0<br />

6SL3200-0SF52-0AA0<br />

6SL3200-0SF53-0AA0<br />

6SL3200-0SF54-0AA0<br />

6SL3200-0SF15-0AA0<br />

6SL3200-0SF16-0AA0<br />

6SL3200-0SF17-0AA0<br />

6SL3200-0SF18-0AA0<br />

6SL3300-0SF01-0AA0<br />

6SL3200-0SF50-0AA0<br />

6SL3200-0SC10-0BA0<br />

6SL3200-0SC10-0FA0<br />

6SL3200-0SC10-0PA0<br />

Compact Installation Instructions are supplied in hard copy<br />

form in German and <strong>English</strong> with every SINAMICS G120X.<br />

Further technical specifications and documentation are available<br />

on the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

and via the Drive Technology Configurator (DT Configurator) in<br />

the Siemens Industry Mall:<br />

www.siemens.com/dt-configurator<br />

2/22 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

Unless explicitly specified otherwise, the following technical specifications are valid for all SINAMICS G120X converters.<br />

General technical specifications<br />

Mechanical specifications<br />

Shock and vibration load<br />

• Frame sizes FSA to FSG<br />

- Transport in transport packaging Class 2M3<br />

acc. to EN 61800-5-1 and<br />

EN 60068-2-6<br />

- Vibration during operation acc. to Class 3M1<br />

IEC 60721-3-3: 2002<br />

• Frame sizes FSH and FSJ<br />

- Vibration in transport packaging: ±1.5 mm for 5 ... 9 Hz<br />

Test Fc acc. to EN 60068-2-64 0.5 × g at 9 ... 200 Hz<br />

- Shock in product packaging: ±1.5 mm for 5 ... 9 Hz<br />

Test Fc acc. to EN 60068-2-6 0.5 × g at 9 ... 200 Hz<br />

- Vibration during operation: 0.075 mm at 10 ... 58 Hz<br />

Test Fc acc. to EN 60068-2-6 9.81 m/s² (1 × g) at > 58 ... 200 Hz<br />

- Shock during operation:<br />

Shock type EA<br />

Test acc. to EN 60068-2-27 49 m/s 2 (5 × g)/30 ms<br />

147 m/s 2 (15 × g)/11 ms<br />

Degree of protection<br />

• Frame sizes FSA ... FSJ<br />

• Frame sizes FSA ... FSG<br />

Permissible mounting position<br />

Ambient conditions<br />

Protection class<br />

According to EN 61800-5-1<br />

Touch protection<br />

According to EN 61800-5-1<br />

Humidity, max.<br />

Ambient temperature<br />

IP20/ UL Open Type<br />

Optional IP21/ UL Open Type with IP21 top covers<br />

Vertical wall mounting<br />

Class III (PELV1) for Power Module<br />

Class III (PELV1) for Control Unit 1)<br />

Class I (with protective conductor system)<br />

45 °C (113 °F) with derating<br />

Variants PROFIBUS DP and USS, Modbus RTU, BACnet MS/TP:<br />

-20 °C ... +60 °C (-4 ... +140 °F) with a side clearance of 5 cm or -20 °C ... +50 °C (-4 ... +122 °F) for<br />

side-by-side mounting, >45 °C (113 °F) with derating<br />

- Frame sizes FSH and FSJ 0 ... 55 °C (32 ... 131 °F) , >45 °C (113 °F) with derating<br />

- All frame sizes with operator panel 0...50°C (32...122°F) see also derating characteristics<br />

Environmental class in operation<br />

• Harmful chemical substances<br />

- Frame sizes FSA to FSG Class 3C2 acc. to IEC 60721-3-3: 2002<br />

Optional: Class 3C3 acc. to IEC 60721-3-3: 2002 2)<br />

- Frame sizes FSH and FSJ Class 3C2 acc. to IEC 60721-3-3: 2002<br />

• Organic/biological pollutants Class 3B1 acc. to IEC 60721-3-3: 2002<br />

• Degree of pollution 2 acc. to EN 61800<br />

2<br />

1) Only supported for SINAMICS G120X converters with FS code<br />

02 02 (FSA to FSG) / 02 (FSH/FSJ).<br />

The FS code of the converter is on the rating plate.<br />

2) Only supported for SINAMICS G120X converters with FS code 02 02.<br />

The FS code of the converter is on the rating plate.<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/23


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

General technical specifications (continued)<br />

Standards<br />

Compliance with standards 1)<br />

• Frame sizes FSA to FSG<br />

• Frame sizes FSH and FSJ<br />

CE, UL, cUL, RCM, SEMI F47, RoHS II, EAC, KCC, REACH<br />

CE, UL, cUL, RCM, SEMI F47, RoHS II, EAC, REACH<br />

Fail-safe certification<br />

Function: Safe Torque Off (STO)<br />

External components (e.g. safety relays) are necessary for using the STO safety function.<br />

• According to IEC 615<strong>08</strong> SIL 3<br />

• According to EN ISO 13849-1 PL e and Category 3<br />

CE marking, according to<br />

EMC Directive 2014/30/EU<br />

Low Voltage Directive 2014/35/EU<br />

EMC Directive 1)<br />

acc. to EN 61800-3<br />

• Interference immunity<br />

The SINAMICS G120X converters are tested according to the interference immunity requirements for environments<br />

according to Category C3.<br />

• Interference emissions<br />

2)<br />

- Frame sizes FSA to FSF<br />

without integrated line filter<br />

- Frame sizes FSA to FSG<br />

with integrated line filter<br />

Category C2<br />

- Frame sizes FSG to FSJ<br />

with integrated line filter<br />

Category C3<br />

Observance of the limit values according for conducted RF emissions<br />

according to IEC 61800-3 Category C2 / EN 55011:2016 Class A<br />

Observance of the limit values according for conducted RF emissions<br />

according to IEC 61800-3 Category C3<br />

- Frame sizes FSH and FSJ<br />

Observance of the limit values according for conducted RF emissions<br />

with integrated line filter Category C3 according to IEC 61800-3 Category C2 / EN 55011:2016 Class A<br />

with optional line filter Category C2<br />

and optional line reactor<br />

- Frame sizes FSA to FSF 90 kW<br />

without integrated line filter with<br />

optional line filter Category C1<br />

Observance of the limit values according for conducted RF emissions<br />

according to IEC 61800-3 Category C1 / EN 55011:2016 Class B<br />

- Frame size FSF 110 kW<br />

Observance of the limit values according for conducted RF emissions<br />

with integrated line filter Category C2 according to IEC 61800-3 Category C1 / EN 55011:2016 Class B<br />

with optional line filter Category C1<br />

Note:<br />

The EMC product standard EN 61800-3 does not apply directly to a frequency converter but to a PDS (Power Drive<br />

System), which comprises the <strong>complete</strong> circuitry, motor and cables in addition to the converter. The frequency converters<br />

on their own do not generally require identification according to the EMC Directive.<br />

1) Additional information is available in the operating instructions on the<br />

Internet at: www.siemens.com/sinamics-g120x/documentation<br />

2) Non-filtered devices are designed for operation in IT systems or in conjunction<br />

with an RCD. The customer must provide suitable RI suppression<br />

equipment to ensure that these devices comply with the limits defined for<br />

Category C3.<br />

2/24 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

SINAMICS G120X converters<br />

Integrated bus interface Variant PROFINET, EtherNet/IP Variant PROFIBUS DP Variant USS, Modbus RTU,<br />

BACnet MS/TP<br />

Fieldbus protocols<br />

Hardware<br />

I/O interfaces<br />

Signal cable cross-section<br />

Digital inputs – standard<br />

• Switching level: 0 1<br />

• Switching level: 1 0<br />

Digital inputs – fail-safe<br />

Digital outputs<br />

Analog inputs<br />

• Switching threshold: 0 1<br />

• Switching threshold: 1 0<br />

Analog outputs<br />

PTC/KTY/Pt1000 interface<br />

Voltage supply for the integrated<br />

Control Unit<br />

Tool interfaces<br />

Memory card<br />

Operator panels<br />

•PROFINET<br />

• EtherNet/IP<br />

2 × RJ45, device name can<br />

be stored on the device,<br />

max. 100 Mbit/s (full duplex)<br />

• PROFIBUS DP<br />

0.15 ... 1.5 mm 2 (28 ... 16 AWG)<br />

6 isolated inputs<br />

Optically isolated;<br />

Free reference potential (own potential group)<br />

NPN/PNP logic can be selected using the wiring<br />

11 V<br />

5V<br />

9-pin SUB-D socket, isolated,<br />

max. 12 Mbit/s<br />

1 isolated input<br />

Max. input voltage 60 V<br />

Safety function: Safe Torque Off (STO)<br />

External components (e.g. safety relays) are necessary for using the STO safety function.<br />

2 relay changeover contacts<br />

250 V AC, 2 A (inductive load),<br />

30 V DC, 5 A (ohmic load)<br />

2 analog inputs<br />

Differential input<br />

Switchable between voltage (-10 ... +10 V) and current (0/4 ... 20 mA) using a DIP switch<br />

12-bit resolution<br />

Can be used as additional digital input<br />

4V<br />

1.6 V<br />

•USS<br />

• Modbus RTU<br />

• BACnet MS/TP<br />

RS485 connected at a terminal, isolated,<br />

bus terminating resistor can be<br />

switched in,<br />

USS: max. 187.5 kBaud<br />

Modbus RTU:19.2 kBaud<br />

BACnet MS/TP: max. 187.5 kBaud<br />

1 non-isolated output<br />

Switchable between voltage (0 ... 10 V) and current (0/4 ... 20 mA) using a parameter<br />

Voltage mode: 10 V, min. burden 10 k<br />

Current mode: 20 mA, max. burden 500 <br />

The analog outputs have short-circuit protection<br />

1 motor temperature sensor input<br />

Connectable sensors PTC, Pt1000, KTY and bimetal,<br />

accuracy ±5 °C<br />

Note:<br />

Connection and evaluation of a recommended, optional Pt100 temperature sensor possible by using a free analog<br />

input and output<br />

24 V DC via the Power Module or by connecting to an external 20.4 ... 28.8 V DC power supply<br />

Typical input current: 500 mA at 24 V DC<br />

Optional<br />

SINAMICS SD card<br />

Optional<br />

BOP-2 Basic Operator Panel or IOP-2 Intelligent Operator Panel or SINAMICS G120 Smart Access<br />

2<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/25


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

SINAMICS G120X converters<br />

Open-loop/closed-loop <strong>control</strong> techniques<br />

V/f linear/quadratic/parameterizable<br />

V/f with flux current <strong>control</strong> (FCC)<br />

V/f ECO linear/quadratic<br />

Vector <strong>control</strong>, sensorless<br />

Software functions<br />

Setpoint input, can be parameterized<br />

Fixed frequencies<br />

JOG<br />

Digital motorized potentiometer<br />

(MOP)<br />

Ramp smoothing<br />

Extended ramp-function generator<br />

(with ramp smoothing OFF3)<br />

Slip compensation<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

16, parameterizable<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

Switchable drive data sets (DDS) ✓ (4)<br />

Switchable command data sets (CDS) ✓ (2)<br />

Free function blocks (FFB) for ✓ (for frame sizes FSA to FSG)<br />

logical and arithmetic operations<br />

Flying restart<br />

Automatic restart<br />

after line supply failure or operating<br />

fault (AR)<br />

Technology <strong>control</strong>ler (internal PID)<br />

Energy saving display<br />

✓<br />

✓<br />

✓<br />

✓<br />

3 additional, free PID <strong>control</strong>lers ✓<br />

Hibernation mode with internal/ ✓<br />

external PID <strong>control</strong>ler<br />

Belt monitoring with and without<br />

sensor (load torque monitoring)<br />

Dry-running/overload protection<br />

monitoring (load torque monitoring)<br />

Deragging<br />

Thermal motor protection<br />

Thermal converter protection<br />

Motor identification<br />

Auto-ramping (V dc_max <strong>control</strong>ler)<br />

Kinetic buffering (V dc_min <strong>control</strong>ler)<br />

Braking functions<br />

•DC braking<br />

• Compound braking<br />

✓<br />

✓<br />

✓<br />

✓ (I 2 t, sensor: PTC, Pt100, Pt1000, KTY and bimetal)<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

✓<br />

2/26 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

General technical specifications of the power electronics<br />

System operating voltage<br />

• Frame sizes FSA to FSG<br />

For systems complying with IEC:<br />

200 ... 240 V 3 AC +10 % -20 %<br />

380 ... 480 V 3 AC +10 % -20 %<br />

500 ... 690 V 3 AC +10 % -20 %<br />

For systems complying with UL:<br />

200 ... 240 V 3 AC<br />

380 ... 480 V 3 AC<br />

500 ... 600 V 3 AC<br />

• Frame sizes FSH and FSJ 380 ... 480 V 3 AC +10 % -15 %<br />

500 ... 690 V 3 AC +10 % -15 %<br />

Line supply requirements<br />

Line impedance u K<br />

• Frame sizes FSA to FSG 4%<br />

• Frame sizes FSH and FSJ<br />

Input frequency<br />

Output frequency<br />

• Frame sizes FSA to FSG<br />

• Frame sizes FSH and FSJ<br />

A line reactor (u K = 2 %) must be connected in series, if the short-circuit power ratio R SC > 33 (315 ... 500 kW) or<br />

R SC > 20 (560 kW)<br />

47 ... 63 Hz<br />

Control mode V/f: 0 ... 550 Hz<br />

Control mode Vector: 0 ... 240 Hz<br />

Control mode V/f: 0 ... 150 Hz<br />

Control mode Vector: 0 ... 150 Hz<br />

Pulse frequency<br />

• Frame sizes FSA to FSG 200 V:<br />

4 kHz<br />

Higher pulse frequencies up to 16 kHz see derating data<br />

400 V:<br />

4 kHz for converters with a rated power 90 kW<br />

2 kHz for converters with a rated power 110 kW<br />

Higher pulse frequencies up to 16 kHz see derating data<br />

690 V:<br />

2kHz<br />

Higher pulse frequencies up to 4 kHz see derating data<br />

• Frame sizes FSH and FSJ<br />

2kHz<br />

Self-adjusting up to 4 kHz see derating data<br />

Power factor <br />

• Frame sizes FSA to FSG 0.75 ... 0.93<br />

• Frame sizes FSH and FSJ 0.75 ... 0.93 (with line reactor u K =2%)<br />

Offset factor cos <br />

• Frame sizes FSA to FSC 0.96<br />

• Frame sizes FSD to FSG 0.99<br />

• Frame sizes FSH and FSJ 0.96<br />

Output voltage, max.<br />

97 %<br />

as % of line voltage<br />

Overload capability<br />

• Low overload (LO)<br />

1.1 × base-load current I L (i. e. 110 % overload) for 60 s within a cycle time of 300 s<br />

• High overload (HO)<br />

Cooling<br />

Installation altitude<br />

Short Circuit Current Rating (SCCR)<br />

max.<br />

Protection functions<br />

1.5 × base-load current I H (i. e. 150 % overload) for 60 s within a cycle time of 600 s<br />

Air cooling using an integrated fan<br />

Up to 1000 m (3281 ft) above sea level without derating,<br />

>1000 m (3281 ft) see derating characteristics<br />

100 kA see Recommended line-side overcurrent protection devices – the value depends on the fuses and circuit<br />

breakers used<br />

For more information, see:<br />

https://support.industry.siemens.com/cs/document/109762895<br />

• Undervoltage<br />

•Overvoltage<br />

• Overcurrent/overload<br />

• Ground fault<br />

• Short-circuit<br />

• Stall protection<br />

• Motor blocking protection<br />

• Motor overtemperature<br />

• Converter overtemperature<br />

• Parameter locking<br />

2<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/27


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

Maximum permissible motor cable lengths SINAMICS G120X<br />

The values specified in the table below apply with low-capacitance CY cables and with pulse frequencies set in the factory.<br />

Without compliance to the EMC category<br />

Maximum permissible motor cable lengths (shielded/unshielded) in m (ft)<br />

FSA to FSC FSD and FSE FSF and FSG FSH and FSJ<br />

Converters without optional power components<br />

• 200 V versions 150/300 (492/984) 200/300 (656/984) FSF: 300/450 (984/1476) –<br />

• 400 V versions 150/300 (492/984) 200/300 (656/984) 300/450 (984/1476) 150/200 (492/656)<br />

• 690 V versions – FSD 30 kW: 200/300 (656/984) 300/450 (984/1476) 150/200 (492/656)<br />

FSD 37 kW, FSE: 300/450 (984/1476)<br />

Converters with one optional output reactor<br />

• 200 V versions – – – –<br />

• 400 V versions – 200/300 (656/984) 1) 300/450 (984/1476) 1) 300/450 (984/1476)<br />

• 690 V versions – FSD 30 kW: 200/300 (656/984) 1)<br />

FSD 37 kW, FSE: 300/450 (984/1476) 1) 300/450 (984/1476) 1) 300/450 (984/1476)<br />

Converters with two in series connected optional output reactors 1)<br />

• 200 V versions – – – –<br />

• 400 V versions – 350/525 (1148/1723) 525/800 (1723/2625) –<br />

• 690 V versions – FSD 30 kW: 350/525 (1148/1723) 525/800 (1723/2625) –<br />

FSD 37 kW, FSE: 525/800 (1723/2625)<br />

Converters with optional sine-wave filter<br />

• 200 V versions – – – –<br />

• 400 V versions 200/300 (656/984) 200/300 (656/984) FSF: 200/300 (656/984) –<br />

FSG: 300/450 (984/1476)<br />

• 690 V versions – – – –<br />

Converters with optional dv/dt filter plus VPL<br />

• 200 V versions – – – –<br />

• 400 V versions – 350/525 (1148/1723) 650/800 (2133/2625) 300/450 (984/1476)<br />

• 690 V versions – FSD 30 kW: 350/525 (1148/1723) 450/625 (1476/2051) 2) 300/450 (984/1476)<br />

FSD 37 kW, FSE: 450/625 (1476/2051) 2)<br />

With compliance to the EMC category 3)<br />

Converters with integrated line filter<br />

for observance of the limit values for conducted RF emissions according to IEC 61800-3 Category C3<br />

• 200 V versions – – – –<br />

• 400 V versions 150/– (492/–) 200/– (656/–) 200/– (656/–) 150/– (492/–) 4)<br />

• 690 V versions – 150/– (492/–) 150/– (492/–) 150/– (492/–) 4)<br />

Converters with integrated line filter with external line filter Category C2<br />

for observance of the limit values for conducted RF emissions according to IEC 61800-3 Category C2 / EN 55011:2016 Class A<br />

• 200 V versions – – – –<br />

• 400 V versions – – – 150/– (492/–)<br />

• 690 V versions – – – 150/– (492/–)<br />

Converters with integrated line filter<br />

for observance of the limit values for conducted RF emissions according to IEC 61800-3 Category C2 / EN 55011:2016 Class A<br />

• 200 V versions – – – –<br />

• 400 V versions 150/– (492/–) 150/– (492/–) 150/– (492/–) –<br />

• 690 V versions – 100/– (328/–) – –<br />

Converters with integrated line filter with external sine-wave filter<br />

for observance of the limit values for conducted RF emissions according to IEC 61800-3 Category C2 / EN 55011:2016 Class A or according to IEC 61800-3 Category C3<br />

• 200 V versions – – – –<br />

• 400 V versions<br />

Category C2<br />

FSA: 100/– (328/–)<br />

FSB: 200/– (656/–)<br />

Category C3<br />

FSC: 200/– (656/–)<br />

Category C2<br />

150/– (492/–)<br />

Category C2<br />

150/– (492/–)<br />

• 690 V versions – – – –<br />

Converters without/with integrated line filter with external line filter Category C1<br />

for observance of the limit values for conducted RF emissions according to IEC 61800-3 Category C1 / EN 55011:2016 Class B<br />

• 200 V versions – – – –<br />

• 400 V versions Without integrated line filter Without integrated line filter<br />

Without integrated line filter –<br />

50/– (164/–) 3) 50/– (164/–) 3) FSF 90 kW: 50/– (164/–) 3)<br />

With integrated line filter<br />

FSF 110 kW: 10/– (23.8/–) 3)<br />

• 690 V versions – – – –<br />

–<br />

1) For frame sizes FSD to FSG the maximum permissible cable lengths are not<br />

increased with one output reactor. By means of the output reactor, the loading<br />

of the motor windings is reduced by lower rates of voltage rise (dv/dt).<br />

By means of two output reactors connected in series, the maximum permissible<br />

cable lengths for frame sizes FSD to FSG are increased.<br />

2) Maximum overvoltage at the motor terminals


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 200 ... 240 V 3 AC<br />

6SL32.0-.YC10-.U.0 6SL32.0-.YC12-.U.0 6SL32.0-.YC14-.U.0 6SL32.0-.YC16-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 200 ... 240 200 ... 240 200 ... 240 200 ... 240<br />

Output current at line voltage 200 V<br />

• without overload rated value A 4.4 6.1 7.7 10.8<br />

• with low overload rated value A 4.2 6.0 7.4 10.4<br />

• with high overload rated value A 3.2 4.2 6.0 7.4<br />

• maximum A 5.7 8.1 10.0 14.1<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 200 V<br />

• with low overload kW 0.75 1.1 1.5 2.2<br />

• with high overload kW 0.55 0.75 1.1 1.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 240 V<br />

• with low overload hp 1 1.5 2 3<br />

• with high overload hp 0.75 1 1.5 2<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.96 0.96 0.96 0.96<br />

Power loss maximum 1) kW 0.04 0.05 0.07 0.12<br />

Cooling air flow<br />

m³/s 0.005 (0.177) 0.0092 (0.325) 0.0092 (0.325) 0.0092 (0.325)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 55 55 55 63<br />

level maximum<br />

Input current at line voltage 200 V<br />

• with low overload rated value A 3.8 5.4 6.7 9.6<br />

• with high overload rated value A 2.8 3.8 5.4 6.7<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 16<br />

• Connectable conductor cross-section 18 ... 14 18 ... 14 18 ... 14 10 ... 6<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 6<br />

• Connectable conductor cross-section<br />

(AWG)<br />

18 ... 14 18 ... 14 18 ... 14 10 ... 6<br />

Type of electrical connection for PE<br />

conductor<br />

Cable length for motor<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 73 (2.87402) 73 (2.87402) 73 (2.87402) 100 (3.93701)<br />

•Height mm (in) 232 (9.13386) 232 (9.13386) 232 (9.13386) 275 (10.82677)<br />

•Depth mm (in) 209 (8.22835) 209 (8.22835) 209 (8.22835) 209 (8.22835)<br />

Frame size FSA FSA FSA FSB<br />

Weight, approx. kg (lb) 3.3 (7.275246) 3.3 (7.275246) 3.3 (7.275246) 5.8 (12.786796)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/29


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YC18-.U.0 6SL32.0-.YC20-.U.0 6SL32.0-.YC22-.U.0 6SL32.0-.YC24-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 200 ... 240 200 ... 240 200 ... 240 200 ... 240<br />

Output current at line voltage 200 V<br />

• without overload rated value A 14.1 18.1 22.8 29.0<br />

• with low overload rated value A 13.6 17.5 22.0 28.0<br />

• with high overload rated value A 10.4 13.6 17.5 22.0<br />

• maximum A 18.4 23.7 29.7 37.8<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 200 V<br />

• with low overload kW 3 4 5.5 7.5<br />

• with high overload kW 2.2 3 4 5.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 240 V<br />

• with low overload hp 4 5 7.5 10<br />

• with high overload hp 3 4 5 7.5<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.96 0.96 0.97 0.97<br />

Power loss maximum 1) kW 0.14 0.18 0.2 0.26<br />

Cooling air flow<br />

m³/s 0.0185 (0.653) 0.0185 (0.653) 0.0185 (0.653) 0.0185 (0.653)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 63 63 67 67<br />

level maximum<br />

Input current at line voltage 200 V<br />

• with low overload rated value A 12.7 16.3 20.8 26.3<br />

• with high overload rated value A 9.6 12.7 16.3 20.8<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 16 1.5 ... 16 1.5 ... 16 1.5 ... 16<br />

• Connectable conductor cross-section 10 ... 6 10 ... 6 10 ... 6 10 ... 6<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 6 1.5 ... 6 1.5 ... 16 1.5 ... 16<br />

• Connectable conductor cross-section<br />

(AWG)<br />

10 ... 6 10 ... 6 10 ... 6 10 ... 6<br />

Type of electrical connection for PE<br />

conductor<br />

Cable length for motor<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 100 (3.93701) 100 (3.93701) 140 (5.51181) 140 (5.51181)<br />

•Height mm (in) 275 (10.82677) 275 (10.82677) 295 (11.61417) 295 (11.61417)<br />

•Depth mm (in) 209 (8.22835) 209 (8.22835) 209 (8.22835) 209 (8.22835)<br />

Frame size FSB FSB FSC FSC<br />

Weight, approx. kg (lb) 5.8 (12.786796) 5.8 (12.786796) 7.1 (15.652802) 7.1 (15.652802)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2/30 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

6SL32.0-.YC26-.U.0 6SL32.0-.YC28-.U.0 6SL32.0-.YC30-.U.0 6SL32.0-.YC32-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 200 ... 240 200 ... 240 200 ... 240 200 ... 240<br />

Output current at line voltage 200 V<br />

• without overload rated value A 43 56 70 82<br />

• with low overload rated value A 42 54 68 80<br />

• with high overload rated value A 28 42 54 68<br />

• maximum A 57 73 92 1<strong>08</strong><br />

Supplied active power at rated value of<br />

output voltage and at line voltage 200 V<br />

• with low overload kW 11 15 18.5 22<br />

• with high overload kW 7.5 11 15 18.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 240 V<br />

• with low overload hp 15 20 25 30<br />

• with high overload hp 10 15 20 25<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.97 0.97 0.97 0.97<br />

Power loss maximum 1) kW 0.45 0.61 0.82 0.92<br />

Cooling air flow<br />

m³/s 0.055 (1.942) 0.055 (1.942) 0.055 (1.942) 0.<strong>08</strong>3 (2.931)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 70 70 70 70<br />

level maximum<br />

Input current at line voltage 200 V<br />

• with low overload rated value A 40 51 64 76<br />

• with high overload rated value A 26.3 40 51 64<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 10 ... 35 25 ... 95<br />

• Connectable conductor cross-section 8 ... 2 8...2 8...2 4 ... -1<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 10 ... 35 25 ... 70<br />

• Connectable conductor cross-section 8 ... 2 8...2 8...2 4 ... -1<br />

(AWG)<br />

Type of electrical connection for PE<br />

Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 200 (656.16798) 200 (656.16798) 200 (656.16798) 200 (656.16798)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 200 (7.87402) 200 (7.87402) 200 (7.87402) 275 (10.82677)<br />

•Height mm (in) 472 (18.58268) 472 (18.58268) 472 (18.58268) 551 (21.69291)<br />

•Depth mm (in) 239 (9.40945) 239 (9.40945) 239 (9.40945) 239 (9.40945)<br />

Frame size FSD FSD FSD FSE<br />

Weight, approx. kg (lb) 16.6 (36.596692) 16.6 (36.596692) 16.6 (36.596692) 16.6 (36.596692)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/31


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YC34-.U.0 6SL32.0-.YC36-.U.0 6SL32.0-.YC38-.U.0 6SL32.0-.YC40-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 200 ... 240 200 ... 240 200 ... 240 200 ... 240<br />

Output current at line voltage 200 V<br />

• without overload rated value A 107 133 158 197<br />

• with low overload rated value A 104 130 154 192<br />

• with high overload rated value A 80 104 130 154<br />

• maximum A 141 176 2<strong>08</strong> 260<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 200 V<br />

• with low overload kW 30 37 45 55<br />

• with high overload kW 22 30 37 45<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 240 V<br />

• with low overload hp 40 50 60 75<br />

• with high overload hp 30 40 50 60<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.97 0.97 0.97 0.97<br />

Power loss maximum 1) kW 1.28 1.38 1.72 2.09<br />

Cooling air flow<br />

m³/s 0.<strong>08</strong>3 (2.931) 0.153 (5.4<strong>03</strong>) 0.153 (5.4<strong>03</strong>) 0.153 (5.4<strong>03</strong>)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 70 72 72 72<br />

level maximum<br />

Input current at line voltage 200 V<br />

• with low overload rated value A 98 126 149 172<br />

• with high overload rated value A 76 98 126 149<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals M10 screw M10 screw M10 screw<br />

• Number of connections 1 2 2 2<br />

• Connectable conductor cross-section mm² 25 ... 95 35 ... 120 35 ... 120 35 ... 120<br />

• Connectable conductor cross-section 4 ... -1 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals M10 screw M10 screw M10 screw<br />

• Number of connections 1 2 2 2<br />

• Connectable conductor cross-section mm² 25 ... 70 35 ... 120 35 ... 120 35 ... 120<br />

• Connectable conductor cross-section 4 ... -1 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

Type of electrical connection for PE<br />

Screw-type terminals M10 screw M10 screw M10 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 200 (656.16798) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 450 (1476.37795) 450 (1476.37795) 450 (1476.37795)<br />

Dimensions<br />

•Width mm (in) 275 (10.82677) 305 (12.00787) 305 (12.00787) 305 (12.00787)<br />

•Height mm (in) 551 (21.69291) 709 (27.91339) 709 (27.91339) 709 (27.91339)<br />

•Depth mm (in) 239 (9.40945) 360 (14.17323) 360 (14.17323) 360 (14.17323)<br />

Frame size FSE FSF FSF FSF<br />

Weight, approx. kg (lb) 16.6 (36.596692) 18.8 (41.446856) 17.6 (38.801312) 26.7 (58.863354)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2/32 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 380 ... 480 V 3 AC<br />

6SL32.0-.YE10-.A.0<br />

6SL32.0-.YE10-.U.0<br />

6SL32.0-.YE12-.A.0<br />

6SL32.0-.YE12-.U.0<br />

6SL32.0-.YE14-.A.0<br />

6SL32.0-.YE14-.U.0<br />

6SL32.0-.YE16-.A.0<br />

6SL32.0-.YE16-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 2.3 3.2 4.3 6.1<br />

• with low overload rated value A 2.2 3.1 4.1 5.9<br />

• with high overload rated value A 1.7 2.2 3.1 4.1<br />

• maximum A 2.7 3.4 4.8 6.4<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 0.75 1.1 1.5 2.2<br />

• with high overload kW 0.55 0.75 1.1 1.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 1 1.5 2 3<br />

• with high overload hp 0.75 1 1.5 2<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.04 0.05 0.06 0.<strong>08</strong><br />

Cooling air flow<br />

m³/s 0.005 (635.66406) 0.005 (635.66406) 0.005 (635.66406) 0.005 (635.66406)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 55 55 55 55<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 2.1 2.8 3.6 5.5<br />

• with high overload rated value A 1.62 1.99 2.72 3.82<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 2.5<br />

• Connectable conductor cross-section 18 ... 14 18 ... 14 18 ... 14 18 ... 14<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 2.5 1.5 ... 2.5<br />

• Connectable conductor cross-section<br />

(AWG)<br />

18 ... 14 18 ... 14 18 ... 14 18 ... 14<br />

Type of electrical connection for PE<br />

conductor<br />

Cable length for motor<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 73 (2.87402) 73 (2.87402) 73 (2.87402) 73 (2.87402)<br />

•Height mm (in) 232 (9.13386) 232 (9.13386) 232 (9.13386) 232 (9.13386)<br />

•Depth mm (in) 209 (8.22835) 209 (8.22835) 209 (8.22835) 209 (8.22835)<br />

Frame size FSA FSA FSA FSA<br />

Weight, approx. 3) kg (lb) 3.2 (7.05478) 3.2 (7.05478) 3.2 (7.05478) 3.2 (7.05478)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/33


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YE18-.A.0<br />

6SL32.0-.YE18-.U.0<br />

6SL32.0-.YE20-.A.0<br />

6SL32.0-.YE20-.U.0<br />

6SL32.0-.YE22-.A.0<br />

6SL32.0-.YE22-.U.0<br />

6SL32.0-.YE24-.A.0<br />

6SL32.0-.YE24-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 8 10.5 13.6 18.5<br />

• with low overload rated value A 7.7 10.2 13.2 18<br />

• with high overload rated value A 5.9 7.7 10.2 13.2<br />

• maximum A 9.1 14 18 24<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 3 4 5.5 7.5<br />

• with high overload kW 2.2 3 4 5.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 4 5 7.5 10<br />

• with high overload hp 3 4 5 7.5<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.126 0.138 0.181 0.245<br />

Cooling air flow<br />

m³/s 0.005 (635.66406) 0.005 (635.66406) 0.0092 (1169.62187) 0.0092 (1169.62187)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 55 63 63 63<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 6.9 9.75 12 17<br />

• with high overload rated value A 5.29 7.36 9.27 12.47<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 6...16 6...16 6 ... 16<br />

• Connectable conductor cross-section 18 ... 14 10 ... 6 10 ... 6 10 ... 6<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 1.5 ... 2.5 6...16 6...16 6 ... 16<br />

• Connectable conductor cross-section<br />

(AWG)<br />

18 ... 14 10 ... 6 10 ... 6 10 ... 6<br />

Type of electrical connection for PE<br />

conductor<br />

Cable length for motor<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

On housing with<br />

M4 screw<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 73 (2.87402) 100 (3.93701) 100 (3.93701) 100 (3.93701)<br />

•Height mm (in) 232 (9.13386) 275 (10.82677) 275 (10.82677) 275 (10.82677)<br />

•Depth mm (in) 209 (8.22835) 209 (8.22835) 209 (8.22835) 209 (8.22835)<br />

Frame size FSA FSB FSB FSB<br />

Weight, approx. 3) kg (lb) 3.2 (7.05478) 5.83 (12.85293) 5.83 (12.85293) 5.83 (12.85293)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

2/34 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

6SL32.0-.YE26-.A.0<br />

6SL32.0-.YE26-.U.0<br />

6SL32.0-.YE28-.A.0<br />

6SL32.0-.YE28-.U.0<br />

6SL32.0-.YE30-.A.0<br />

6SL32.0-.YE30-.U.0<br />

6SL32.0-.YE32-.A.0<br />

6SL32.0-.YE32-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 27 33 39 47<br />

• with low overload rated value A 26 32 38 45<br />

• with high overload rated value A 18 26 32 38<br />

• maximum A 35 43 51.3 61<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 11 15 18.5 22<br />

• with high overload kW 7.5 11 15 18.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 15 20 25 30<br />

• with high overload hp 10 15 20 25<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.316 0.396 0.5 0.68<br />

Cooling air flow<br />

m³/s 0.0185 (2351,95680) 0.0185 (2351,95680) 0.055 (6992.30465) 0.055 (6992.30465)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 67 67 70 70<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 24.5 29.5 36 42<br />

• with high overload rated value A 16.96 23.97 33 38<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 6 ... 16 6...16 10 ... 35 10 ... 35<br />

• Connectable conductor cross-section 10 ... 6 10 ... 6 8...2 8 ... 2<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 6 ... 16 6...16 10 ... 35 10 ... 35<br />

• Connectable conductor cross-section 10 ... 6 10 ... 6 8...2 8 ... 2<br />

(AWG)<br />

Type of electrical connection for PE<br />

On housing with On housing with Screw-type terminals Screw-type terminals<br />

conductor<br />

M4 screw<br />

M4 screw<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 200 (656.16798) 200 (656.16798)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 140 (5.51181) 140 (5.51181) 200 (7.87402) 200 (7.87402)<br />

•Height mm (in) 295 (11.61417) 295 (11.61417) 472 (18.58268) 472 (18.58268)<br />

•Depth mm (in) 209 (8.22835) 209 (8.22835) 239 (9.40945) 239 (9.40945)<br />

Frame size FSC FSC FSD FSD<br />

Weight, approx. 3) kg (lb) 7.14 (15.74099) 7.14 (15.74099) 17 (37.47854) 17 (37.47854)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/35


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YE34-.A.0<br />

6SL32.0-.YE34-.U.0<br />

6SL32.0-.YE36-.A.0<br />

6SL32.0-.YE36-.U.0<br />

6SL32.0-.YE38-.A.0<br />

6SL32.0-.YE38-.U.0<br />

6SL32.0-.YE40-.A.0<br />

6SL32.0-.YE40-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 62 77 93 113<br />

• with low overload rated value A 60 75 90 110<br />

• with high overload rated value A 45 60 75 90<br />

• maximum A 81 102 122 149<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 30 37 45 55<br />

• with high overload kW 22 30 37 45<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 40 50 60 75<br />

• with high overload hp 30 40 50 60<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.77 1.02 1.02 1.55<br />

Cooling air flow<br />

m³/s 0.055 (6992.30465) 0.055 (6992.30465) 0.<strong>08</strong>3 (10552.02338) 0.<strong>08</strong>3 (10552.02338)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 70 70 70 70<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 57 70 86 104<br />

• with high overload rated value A 47 62 78 94<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 25 ... 95 25 ... 95<br />

• Connectable conductor cross-section 8 ... 2 8...2 4...-1 4 ... -1<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 25 ... 95 25 ... 95<br />

• Connectable conductor cross-section 8 ... 2 8...2 4...-1 4 ... -1<br />

(AWG)<br />

Type of electrical connection for PE<br />

Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 200 (656.16798) 200 (656.16798) 200 (656.16798) 200 (656.16798)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 200 (7.87402) 200 (7.87402) 275 (10.82677) 275 (10.82677)<br />

•Height mm (in) 472 (18.58268) 472 (18.58268) 551 (21.69291) 551 (21.69291)<br />

•Depth mm (in) 239 (9.40945) 239 (9.40945) 239 (9.40945) 239 (9.40945)<br />

Frame size FSD FSD FSE FSE<br />

Weight, approx. 3) kg (lb) 17 (37.47854) 19 (41.88778) 27 (59.52474) 27 (59.52474)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

2/36 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

6SL32.0-.YE42-.A.0<br />

6SL32.0-.YE42-.U.0<br />

6SL32.0-.YE44-.A.0<br />

6SL32.0-.YE44-.U.0<br />

6SL32.0-.YE46-.A.0<br />

6SL32.0-.YE46-.U.0<br />

6SL32.0-.YE48-.A.0<br />

6SL32.0-.YE48-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 149 183 210 256<br />

• with low overload rated value A 145 178 205 250<br />

• with high overload rated value A 110 145 178 205<br />

• maximum A 196 241 277 338<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 75 90 110 132<br />

• with high overload kW 55 75 90 110<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 100 125 150 200<br />

• with high overload hp 75 100 125 150<br />

Pulse frequency kHz 4 4 4 4<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 1.23 1.57 1.83 2.35<br />

Cooling air flow<br />

m³/s 0.153 (19451.32021) 0.153 (19451.32021) 0.153 (19451.32021) 0.153 (19451.32021)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 72 72 72 72<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 140 172 198 242<br />

• with high overload rated value A 117 154 189 218<br />

for mains supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M10 screw<br />

• Number of connections 2 2 2 2<br />

• Connectable conductor cross-section mm² 35 ... 120 35 ... 120 35 ... 120 35 ... 120<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M10 screw<br />

• Number of connections 2 2 2 2<br />

• Connectable conductor cross-section mm² 35 ... 120 35 ... 120 35 ... 120 35 ... 120<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

Type of electrical connection for PE<br />

M10 screw M10 screw M10 screw M10 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

• unshielded maximum 2) m(ft) 450 (1476.37795) 450 (1476.37795) 450 (1476.37795) 450 (1476.37795)<br />

Dimensions<br />

•Width mm (in) 305 (12.00787) 305 (12.00787) 305 (12.00787) 305 (12.00787)<br />

•Height mm (in) 709 (27.91339) 709 (27.91339) 709 (27.91339) 709 (27.91339)<br />

•Depth mm (in) 360 (14.17323) 360 (14.17323) 360 (14.17323) 360 (14.17323)<br />

Frame size FSF FSF FSF FSF<br />

Weight, approx. 3) kg (lb) 61 (134.48182) 61 (134.48182) 67 (147.70954) 67 (147.70954)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/37


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YE50-.A.0<br />

6SL32.0-.YE50-.C.0<br />

6SL32.0-.YE52-.A.0<br />

6SL32.0-.YE52-.C.0<br />

6SL32.0-.YE54-.A.0<br />

6SL32.0-.YE54-.C.0<br />

6SL3220-.YE56-.C.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 309 379 488 585<br />

• with low overload rated value A 302 370 477 570<br />

• with high overload rated value A 250 302 370 468<br />

• maximum A 4<strong>08</strong> 500 644 770<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 160 200 250 315<br />

• with high overload kW 132 160 200 250<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 250 300 400 400<br />

• with high overload hp 200 250 300 300<br />

Pulse frequency kHz 4 4 4 2<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 3.67 4.62 6.18 6.791<br />

Cooling air flow<br />

m³/s 0.21 (26697.89049) 0.21 (26697.89049) 0.21 (26697.89049) 0.362 (46022.07788)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 74 74 74 74<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 301 365 471 585<br />

• with high overload rated value A 275 330 400 477<br />

for mains supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M12 screw<br />

• Number of connections 2 2 2 4<br />

• Connectable conductor cross-section mm² 35 ... 185 35 ... 185 35 ... 185 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M12 screw<br />

• Number of connections 2 2 2 4<br />

• Connectable conductor cross-section mm² 35 ... 185 35 ... 185 35 ... 185 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

Type of electrical connection for PE<br />

M10 screw M10 screw M10 screw M12 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 200 (656.16798) 200 (656.16798) 200 (656.16798) 150 (492.12598)<br />

Dimensions<br />

•Width mm (in) 305 (12.00787) 305 (12.00787) 305 (12.00787) 548 (21.5748)<br />

•Height mm (in) 999 (39.33071) 999 (39.33071) 999 (39.33071) 1695 (66.73228)<br />

•Depth mm (in) 360 (14.17323) 360 (14.17323) 360 (14.17323) 393 (15.47244)<br />

Frame size FSG FSG FSG FSH<br />

Weight, approx. kg (lb) 105 (231.48536) 113 (249.12234) 120 (264.5547) 151 (332.89799)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2/38 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

2) The values apply with compliance to the EMC category C3.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

6SL3220-.YE58-.C.0 6SL3220-.YE60-.C.0 6SL3220-.YE62-.C.0 6SL3220-.YE64-.C.0 6SL3220-.YE66-.C.0<br />

Type of voltage 3AC 3AC 3AC 3AC 3AC<br />

Line voltage V 380 ... 480 380 ... 480 380 ... 480 380 ... 480 380 ... 480<br />

Output current at line voltage 400 V<br />

• without overload rated value A 655 735 840 910 1021<br />

• with low overload rated value A 640 720 820 890 1000<br />

• with high overload rated value A 491 551 672 728 786<br />

• maximum A 864 972 1107 1202 1350<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 400 V<br />

• with low overload kW 355 400 450 500 560<br />

• with high overload kW 250 315 355 400 450<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 480 V<br />

• with low overload hp 450 500 500 600 700<br />

• with high overload hp 300 350 450 500 500<br />

Pulse frequency kHz 2 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 7.687 8.385 10.418 10.885 12.496<br />

Cooling air flow<br />

m³/s 0.362 (46022.07788) 0.362 (46022.07788) 0.45 (57209.76533) 0.45 (57209.76533) 0.45 (57209.76533)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 74 74 74 74 74<br />

level maximum<br />

Input current at line voltage 400 V<br />

• with low overload rated value A 654 735 850 924 1<strong>03</strong>8<br />

• with high overload rated value A 501 562 696 756 816<br />

for mains supply line<br />

• Type of electrical connection M12 screw M12 screw M12 screw M12 screw M12 screw<br />

• Number of connections 4 4 6 6 6<br />

• Connectable conductor cross-section mm² 35 ... 240 35 ... 240 35 ... 240 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection M12 screw M12 screw M12 screw M12 screw M12 screw<br />

• Number of connections 4 4 6 6 6<br />

• Connectable conductor cross-section mm² 35 ... 240 35 ... 240 35 ... 240 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

Type of electrical connection for PE<br />

M12 screw M12 screw M12 screw M12 screw M12 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

Dimensions<br />

•Width mm (in) 548 (21.5748) 548 (21.5748) 801 (31.53543) 801 (31.53543) 801 (31.53543)<br />

•Height mm (in) 1695 (66.73228) 1695 (66.73228) 1621 (63.8189) 1621 (63.8189) 1621 (63.8189)<br />

•Depth mm (in) 393 (15.47244) 393 (15.47244) 393 (15.47244) 393 (15.47244) 393 (15.47244)<br />

Frame size FSH FSH FSJ FSJ FSJ<br />

Weight, approx. kg (lb) 157 (346.12573) 159 (350.53497) 236 (520.2909) 250 (551.15562) 250 (551.15562)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply with compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/39


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

SINAMICS G120X converters · Degree of protection IP20/UL Open Type · 500 ... 690 V 3 AC<br />

6SL32.0-.YH18-.A.0<br />

6SL32.0-.YH18-.U.0<br />

6SL32.0-.YH20-.A.0<br />

6SL32.0-.YH20-.U.0<br />

6SL32.0-.YH22-.A.0<br />

6SL32.0-.YH22-.U.0<br />

6SL32.0-.YH24-.A.0<br />

6SL32.0-.YH24-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 500 ... 690 500 ... 690 500 ... 690 500 ... 690<br />

Output current at line voltage 690 V<br />

• without overload rated value A 6 7 10 12<br />

• with low overload rated value A 5 6.3 9 11<br />

• with high overload rated value A 4 5 6.3 9<br />

• maximum A 7 9 13 15<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 690 V<br />

• with low overload kW 3 4 5.5 7.5<br />

• with high overload kW 2.2 3 4 5.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 600 V<br />

• with low overload hp 4 5 7.5 10<br />

• with high overload hp 3 4 5 7.5<br />

Pulse frequency kHz 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.35 0.35 0.35 0.35<br />

Cooling air flow<br />

m³/s 0.055 (6992.30465) 0.055 (6992.30465) 0.055 (6992.30465) 0.055 (6992.30465)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 70 70 70 70<br />

level maximum<br />

Input current at line voltage 690 V<br />

• with low overload rated value A 6 7 10 12<br />

• with high overload rated value A 4.8 5.56 7 9.82<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 10 ... 35 10 ... 35<br />

• Connectable conductor cross-section 8 ... 2 8...2 8...2 8 ... 2<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 10 ... 35 10 ... 35<br />

• Connectable conductor cross-section 8 ... 2 8...2 8...2 8 ... 2<br />

(AWG)<br />

Type of electrical connection for PE<br />

Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 200 (656.16798) 200 (656.16798) 200 (656.16798) 200 (656.16798)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 200 (7.87402) 200 (7.87402) 200 (7.87402) 200 (7.87402)<br />

•Height mm (in) 472 (18.58268) 472 (18.58268) 472 (18.58268) 472 (18.58268)<br />

•Depth mm (in) 239 (9.40945) 239 (9.40945) 239 (9.40945) 239 (9.40945)<br />

Frame size FSD FSD FSD FSD<br />

Weight, approx. 3) kg (lb) 16.6 (36.59669) 16.6 (36.59669) 16.6 (36.59669) 16.6 (36.59669)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

2/40 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

6SL32.0-.YH26-.A.0<br />

6SL32.0-.YH26-.U.0<br />

6SL32.0-.YH28-.A.0<br />

6SL32.0-.YH28-.U.0<br />

6SL32.0-.YH30-.A.0<br />

6SL32.0-.YH30-.U.0<br />

6SL32.0-.YH32-.A.0<br />

6SL32.0-.YH32-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 500 ... 690 500 ... 690 500 ... 690 500 ... 690<br />

Output current at line voltage 690 V<br />

• without overload rated value A 15 20 24 28<br />

• with low overload rated value A 14 19 23 27<br />

• with high overload rated value A 11 14 19 23<br />

• maximum A 19 26 32 37<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 690 V<br />

• with low overload kW 11 15 18.5 22<br />

• with high overload kW 7.5 11 15 18.5<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 600 V<br />

• with low overload hp 10 15 20 25<br />

• with high overload hp 10 10 15 20<br />

Pulse frequency kHz 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.35 0.45 0.52 0.6<br />

Cooling air flow<br />

m³/s 0.055 (6992.30465) 0.055 (6992.30465) 0.055 (6992.30465) 0.055 (6992.30465)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 70 70 70 70<br />

level maximum<br />

Input current at line voltage 690 V<br />

• with low overload rated value A 15 19 23 26<br />

• with high overload rated value A 11.79 14 19 22.15<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 10 ... 35 10 ... 35<br />

• Connectable conductor cross-section 8 ... 2 8...2 8...2 8 ... 2<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 10 ... 35 10 ... 35<br />

• Connectable conductor cross-section 8 ... 2 8...2 8...2 8 ... 2<br />

(AWG)<br />

Type of electrical connection for PE<br />

Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 200 (656.16798) 200 (656.16798) 200 (656.16798) 200 (656.16798)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

Dimensions<br />

•Width mm (in) 200 (7.87402) 200 (7.87402) 200 (7.87402) 200 (7.87402)<br />

•Height mm (in) 472 (18.58268) 472 (18.58268) 472 (18.58268) 472 (18.58268)<br />

•Depth mm (in) 239 (9.40945) 239 (9.40945) 239 (9.40945) 239 (9.40945)<br />

Frame size FSD FSD FSD FSD<br />

Weight, approx. 3) kg (lb) 16.6 (36.59669) 16.6 (36.59669) 16.6 (36.59669) 16.6 (36.59669)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/41


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YH34-.A.0<br />

6SL32.0-.YH34-.U.0<br />

6SL32.0-.YH36-.A.0<br />

6SL32.0-.YH36-.U.0<br />

6SL32.0-.YH38-.U.0<br />

6SL32.0-.YH38-.A.0<br />

6SL32.0-.YH40-.A.0<br />

6SL32.0-.YH40-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 500 ... 690 500 ... 690 500 ... 690 500 ... 690<br />

Output current at line voltage 690 V<br />

• without overload rated value A 36 43 54 64<br />

• with low overload rated value A 35 42 52 62<br />

• with high overload rated value A 27 35 42 52<br />

• maximum A 48 57 71 84<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 690 V<br />

• with low overload kW 30 37 45 55<br />

• with high overload kW 22 30 37 45<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 600 V<br />

• with low overload hp 30 40 50 60<br />

• with high overload hp 25 30 40 50<br />

Pulse frequency kHz 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 0.78 0.94 1.<strong>08</strong> 1.31<br />

Cooling air flow<br />

m³/s 0.055 (6992.30465) 0.055 (6992.30465) 0.<strong>08</strong>3 (10552.02338) 0.<strong>08</strong>3 (10552.02338)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 70 70 70 70<br />

level maximum<br />

Input current at line voltage 690 V<br />

• with low overload rated value A 34 41 52 60<br />

• with high overload rated value A 26.23 34.17 42 50.32<br />

for mains supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 25 ... 95 25 ... 95<br />

• Connectable conductor cross-section 8 ... 2 8...2 4...-1 4 ... -1<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

• Number of connections 1 1 1 1<br />

• Connectable conductor cross-section mm² 10 ... 35 10 ... 35 25 ... 95 25 ... 95<br />

• Connectable conductor cross-section 8 ... 2 8...2 4...-1 4 ... -1<br />

(AWG)<br />

Type of electrical connection for PE<br />

Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 200 (656.16798) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

• unshielded maximum 2) m(ft) 300 (984.25197) 450 (1476.37795) 450 (1476.37795) 450 (1476.37795)<br />

Dimensions<br />

•Width mm (in) 200 (7.87402) 200 (7.87402) 275 (10.82677) 275 (10.82677)<br />

•Height mm (in) 472 (18.58268) 472 (18.58268) 551 (21.69291) 551 (21.69291)<br />

•Depth mm (in) 239 (9.40945) 239 (9.40945) 239 (9.40945) 239 (9.40945)<br />

Frame size FSD FSD FSE FSE<br />

Weight, approx. 3) kg (lb) 16.6 (36.59669) 18.8 (41.44686) 26.7 (58.86342) 26.7 (58.86342)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

2/42 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

6SL32.0-.YH42-.C.0<br />

6SL32.0-.YH42-.U.0<br />

6SL32.0-.YH44-.C.0<br />

6SL32.0-.YH44-.U.0<br />

6SL32.0-.YH46-.C.0<br />

6SL32.0-.YH46-.U.0<br />

6SL32.0-.YH48-.C.0<br />

6SL32.0-.YH48-.U.0<br />

Type of voltage 3AC 3AC 3AC 3AC<br />

Line voltage V 500 ... 690 500 ... 690 500 ... 690 500 ... 690<br />

Output current at line voltage 690 V<br />

• without overload rated value A 82 1<strong>03</strong> 128 148<br />

• with low overload rated value A 80 100 125 144<br />

• with high overload rated value A 62 80 100 125<br />

• maximum A 1<strong>08</strong> 135 169 195<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 690 V<br />

• with low overload kW 75 90 110 132<br />

• with high overload kW 55 75 90 110<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 600 V<br />

• with low overload hp 75 100 125 150<br />

• with high overload hp 60 75 100 125<br />

Pulse frequency kHz 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 1.38 1.76 1.97 2.51<br />

Cooling air flow<br />

m³/s 0.153 (19451.32021) 0.153 (19451.32021) 0.153 (19451.32021) 0.153 (19451.32021)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 72 72 72 72<br />

level maximum<br />

Input current at line voltage 690 V<br />

• with low overload rated value A 80 99 124 141<br />

• with high overload rated value A 66 85 106 122<br />

for mains supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M10 screw<br />

• Number of connections 2 2 2 2<br />

• Connectable conductor cross-section mm² 35 ... 120 35 ... 120 35 ... 120 35 ... 120<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M10 screw<br />

• Number of connections 2 2 2 2<br />

• Connectable conductor cross-section mm² 35 ... 120 35 ... 120 35 ... 120 35 ... 120<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2 ... -3<br />

(AWG)<br />

Type of electrical connection for PE<br />

M10 screw M10 screw M10 screw M10 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 300 (984.25197) 300 (984.25197) 300 (984.25197) 300 (984.25197)<br />

• unshielded maximum 2) m(ft) 450 (1476.37795) 450 (1476.37795) 450 (1476.37795) 450 (1476.37795)<br />

Dimensions<br />

•Width mm (in) 305 (12.00787) 305 (12.00787) 305 (12.00787) 305 (12.00787)<br />

•Height mm (in) 709 (27.91339) 709 (27.91339) 709 (27.91339) 709 (27.91339)<br />

•Depth mm (in) 360 (14.17323) 360 (14.17323) 360 (14.17323) 360 (14.17323)<br />

Frame size FSF FSF FSF FSF<br />

Weight, approx. 3) kg (lb) 61 (134.48182) 61 (134.48182) 66.5 (146.60723) 66.5 (146.60723)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply without compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

3) The values apply for converters without integrated line filter.<br />

For more information, see on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/43


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Technical specifications<br />

6SL32.0-.YH50-.C.0 6SL32.0-.YH52-.C.0 6SL32.0-.YH54-.C.0 6SL3220-.YH56-.C.0 6SL3220-.YH58-.C.0<br />

Type of voltage 3AC 3AC 3AC 3AC 3AC<br />

Line voltage V 500 ... 690 500 ... 690 500 ... 690 500 ... 690 500 ... 690<br />

Output current at line voltage 690 V<br />

• without overload rated value A 175 213 256 368 400<br />

• with low overload rated value A 171 2<strong>08</strong> 250 330 385<br />

• with high overload rated value A 144 171 2<strong>08</strong> 272 314<br />

• maximum A 231 281 338 487 529<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 690 V<br />

• with low overload kW 160 200 250 315 355<br />

• with high overload kW 132 160 200 250 315<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 600 V<br />

• with low overload hp 150 200 250 350 400<br />

• with high overload hp 150 150 200 250 350<br />

Pulse frequency kHz 2 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 2.94 3.7 4.64 5.402 6.191<br />

Cooling air flow<br />

m³/s 0.21 (26697.89049) 0.21 (26697.89049) 0.21 (26697.89049) 0.362 (46022.07788) 0.362 (46022.07788)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 74 74 74 74 74<br />

level maximum<br />

Input current at line voltage 690 V<br />

• with low overload rated value A 175 210 255 343 401<br />

• with high overload rated value A 160 185 225 283 327<br />

for mains supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M12 screw M12 screw<br />

• Number of connections 2 2 2 4 4<br />

• Connectable conductor cross-section mm² 35 ... 185 35 ... 185 35 ... 185 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection M10 screw M10 screw M10 screw M12 screw M12 screw<br />

• Number of connections 2 2 2 4 4<br />

• Connectable conductor cross-section mm² 35 ... 185 35 ... 185 35 ... 185 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

Type of electrical connection for PE<br />

M10 screw M10 screw M10 screw M12 screw M12 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

Dimensions<br />

•Width mm (in) 305 (12.00787) 305 (12.00787) 305 (12.00787) 548 (21.5748) 548 (21.5748)<br />

•Height mm (in) 999 (39.33071) 999 (39.33071) 999 (39.33071) 1695 (66.73228) 1695 (66.73228)<br />

•Depth mm (in) 360 (14.17323) 360 (14.17323) 360 (14.17323) 393 (15.47244) 393 (15.47244)<br />

Frame size FSG FSG FSG FSH FSH<br />

Weight, approx. kg (lb) 105 (231.48536) 113 (249.12234) 120 (264.5547) 158 (348.33<strong>03</strong>5) 158 (348.33<strong>03</strong>5)<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2/44 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

2) The values apply with compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Technical specifications<br />

6SL3220-.YH60-.C.0 6SL3220-.YH62-.C.0 6SL3220-.YH64-.C.0 6SL3220-.YH66-.C.0 6SL3220-.YH68-.C.0<br />

Type of voltage 3AC 3AC 3AC 3AC 3AC<br />

Line voltage V 500 ... 690 500 ... 690 500 ... 690 500 ... 690 500 ... 690<br />

Output current at line voltage 690 V<br />

• without overload rated value A 453 516 581 654 725<br />

• with low overload rated value A 420 470 520 580 650<br />

• with high overload rated value A 348 394 444 476 532<br />

• maximum A 598 682 768 864 959<br />

Supplied active power at rated value of<br />

output voltage and at line voltage 690 V<br />

• with low overload kW 400 450 500 560 630<br />

• with high overload kW 355 400 450 500 560<br />

Supplied active power [hp] at rated<br />

value of output voltage and at line<br />

voltage 600 V<br />

• with low overload hp 450 500 500 600 700<br />

• with high overload hp 400 450 500 500 600<br />

Pulse frequency kHz 2 2 2 2 2<br />

Efficiency 0.98 0.98 0.98 0.98 0.98<br />

Power loss maximum 1) kW 6.884 7.716 8.134 8.828 9.937<br />

Cooling air flow<br />

m³/s 0.362 (46022.07788) 0.362 (46022.07788) 0.45 (57209.76533) 0.45 (57209.76533) 0.45 (57209.76533)<br />

(ft³/h)<br />

1 m measuring surface sound pressure dB 74 74 74 74 74<br />

level maximum<br />

Input current at line voltage 690 V<br />

• with low overload rated value A 437 489 540 602 675<br />

• with high overload rated value A 362 410 461 494 552<br />

for mains supply line<br />

• Type of electrical connection M12 screw M12 screw M12 screw M12 screw M12 screw<br />

• Number of connections 4 4 6 6 6<br />

• Connectable conductor cross-section mm² 35 ... 240 35 ... 240 35 ... 240 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

for motor supply line<br />

• Type of electrical connection M12 screw M12 screw M12 screw M12 screw M12 screw<br />

• Number of connections 4 4 6 6 6<br />

• Connectable conductor cross-section mm² 35 ... 240 35 ... 240 35 ... 240 35 ... 240 35 ... 240<br />

• Connectable conductor cross-section 2 ... -3 2...-3 2...-3 2...-3 2...-3<br />

(AWG)<br />

Type of electrical connection for PE<br />

M12 screw M12 screw M12 screw M12 screw M12 screw<br />

conductor<br />

Cable length for motor<br />

• shielded maximum 2) m(ft) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598) 150 (492.12598)<br />

• unshielded maximum m(ft) 200 (656.16798) 200 (656.16798) 200 (656.16798) 200 (656.16798) 200 (656.16798)<br />

Dimensions<br />

•Width mm (in) 548 (21.5748) 548 (21.5748) 801 (31.53543) 801 (31.53543) 801 (31.53543)<br />

•Height mm (in) 1695 (66.73228) 1695 (66.73228) 1621 (63.8189) 1621 (63.8189) 1621 (63.8189)<br />

•Depth mm (in) 393 (15.47244) 393 (15.47244) 393 (15.47244) 393 (15.47244) 393 (15.47244)<br />

Frame size FSH FSH FSJ FSJ FSJ<br />

Weight, approx. kg (lb) 162 (357.14884) 162 (357.14884) 236 (520.2909) 236 (520.2909) 246 (542.33713)<br />

2<br />

1) Typical values. More information can be found on the Internet at<br />

https://support.industry.siemens.com/cs/document/94059311<br />

2) The values apply with compliance to the EMC category.<br />

For more information, see Maximum permissible motor cable lengths<br />

SINAMICS G120X and on the Internet at<br />

www.siemens.com/sinamics-g120x/documentation<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/45


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

2<br />

■ Characteristic curves<br />

Derating data<br />

Pulse frequency<br />

Frame size Rated power 1)<br />

at 50 Hz 200 V 3 AC<br />

Rated output current 2) in A (at an ambient temperature of 45 °C (113 °F))<br />

for a pulse frequency of<br />

kW hp 2kHz 4kHz 6kHz 8kHz 10 kHz 12 kHz 14 kHz 16 kHz<br />

FSA 0.75 1 4.2 4.2 3.5 2.9 2.5 2.1 1.8 1.6<br />

1.1 1.5 6 6 5.1 4.2 3.6 3 2.7 2.4<br />

1.5 2 7.4 7.4 6.2 5.1 4.4 3.7 3.3 2.9<br />

FSB 2.2 3 10.4 10.4 8.8 7.2 6.2 5.2 4.6 4.1<br />

3 4 13.6 13.6 11.5 9.5 8.1 6.8 6.1 5.4<br />

4 5 17.5 17.5 14.8 12.2 10.4 8.7 7.8 7<br />

FSC 5.5 7.5 22 22 18.7 15.4 13.2 11 9.9 8.8<br />

7.5 10 28 28 23.8 19.6 16.8 14 12.6 11.2<br />

FSD 11 15 42 42 35.7 29.4 25.2 21 18.9 16.8<br />

15 20 54 54 45.9 37.8 32.4 27 24.3 21.6<br />

18.5 25 68 68 57.8 47.6 40.8 34 30.6 27.2<br />

FSE 22 30 80 80 68 56 48 40 36 32<br />

30 40 104 104 88.4 72.8 62.4 52 46.8 41.6<br />

FSF 37 50 130 130 110.5 91 78 65 58.5 52<br />

45 60 154 154 130.8 107.8 92.4 77 69.3 61.6<br />

55 75 192 192 163.2 134.4 115.2 96 86.4 76.8<br />

The rated output currents in bold apply for the standard pulse frequency.<br />

1) Rated power based on the base-load current I L .<br />

The base-load current I L is based on the duty cycle for low overload (LO).<br />

2) Output current based on the base-load current I L .<br />

The base-load current I L is based on the duty cycle for low overload (LO).<br />

2/46 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Characteristic curves<br />

Frame size Rated power 1)<br />

at 50 Hz 400 V 3 AC<br />

Rated output current 2) in A (at an ambient temperature of 45 °C (113 °F))<br />

for a pulse frequency of<br />

kW hp 2kHz 4kHz 6kHz 8kHz 10 kHz 12 kHz 14 kHz 16 kHz<br />

FSA 0.75 1 2.2 2.2 1.87 1.54 1.32 1.1 0.99 0.88<br />

1.1 1.5 3.1 3.1 2.635 2.17 1.86 1.55 1.395 1.24<br />

1.5 2 4.1 4.1 3.485 2.87 2.46 2.05 1.895 1.64<br />

2.2 3 5.9 5.9 5.015 4.13 3.54 2.95 2.655 2.36<br />

3 4 7.7 7.7 6.545 5.39 4.62 3.85 3.465 3.<strong>08</strong><br />

FSB 4 5 10.2 10.2 8.67 7.14 6.12 5.1 4.59 4.<strong>08</strong><br />

5.5 7.5 13.2 13.2 11.22 9.24 7.92 6.6 5.94 5.28<br />

7.5 10 18 18 15.3 12.6 10.8 9 8.1 7.2<br />

FSC 11 15 26 26 22.1 18.2 15.6 13 11.7 10.4<br />

15 20 32 32 27.2 22.4 19 18 14.4 12.8<br />

FSD 18.5 25 38 38 32.3 26.6 22.8 19 17.1 15.2<br />

22 30 45 45 38.2 31.5 27 22.5 20.2 18<br />

30 40 60 60 51 42 36 30 27 24<br />

37 50 75 75 63.7 52.5 45 37.5 33.7 30<br />

FSE 45 60 90 90 76.5 63 54 45 40.5 36<br />

55 75 110 110 93.5 77 66 55 49.5 44<br />

FSF 75 100 145 145 123.2 101.5 87 72.5 65.2 58<br />

90 125 178 178 151 124.6 107 89 80.1 71.2<br />

110 150 205 143.5 1<strong>03</strong> 82 – – – –<br />

132 200 250 175 125 100 – – – –<br />

FSG 160 250 302 211.4 151 121 – – – –<br />

200 300 370 259 185 148 – – – –<br />

250 400 477 334 239 191 – – – –<br />

FSH 3) 315 400 585 468 – – – – – –<br />

355 450 655 524 – – – – – –<br />

400 500 735 588 – – – – – –<br />

FSJ 3) 450 500 840 672 – – – – – –<br />

500 600 910 728 – – – – – –<br />

560 700 1021 817 – – – – – –<br />

The rated output currents in bold apply for the standard pulse frequency.<br />

2<br />

1) Rated power based on the base-load current I L .<br />

The base-load current I L is based on the duty cycle for low overload (LO).<br />

2) Frame sizes FSA to FSG:<br />

Output current based on the base-load current I L . The base-load current I L<br />

is based on the duty cycle for low overload (LO). Frame sizes FSH and FSJ:<br />

Output current based on the rated output current I rated . The rated output<br />

current I rated can be used up to 100 %;<br />

however, without overload.<br />

3) In the factory setting, these converters start at a pulse frequency of 4 kHz<br />

and reduce it automatically under load to the associated required frequencies.<br />

As the load decreases, the pulse frequency increases automatically<br />

up to 4 kHz.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/47


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Characteristic curves<br />

2<br />

Frame size Rated power 1)<br />

at 50 Hz 690 V 3 AC<br />

Rated output current in A (at an ambient temperature of 45 °C (113 °F))<br />

for a pulse frequency of<br />

kW hp 2kHz 4kHz 6kHz 8kHz 10 kHz 12 kHz 14 kHz 16 kHz<br />

FSD 3 4 6 3.6 – – – – – –<br />

4 5 7 4.2 – – – – – –<br />

5.5 7.5 10 6 – – – – – –<br />

7.5 10 13 7.8 – – – – – –<br />

11 10 16 9.6 – – – – – –<br />

15 15 21 12.6 – – – – – –<br />

18.5 20 25 15 – – – – – –<br />

22 25 29 17.4 – – – – – –<br />

30 30 38 22.8 – – – – – –<br />

37 40 46 27.6 – – – – – –<br />

FSE 45 50 58 34.8 – – – – – –<br />

55 60 68 40.8 – – – – – –<br />

FSF 75 75 90 54 – – – – – –<br />

90 100 112 67.2 – – – – – –<br />

110 125 128 76.8 – – – – – –<br />

132 150 158 94.8 – – – – – –<br />

FSG 160 150 196 118 – – – – – –<br />

200 200 236 142 – – – – – –<br />

250 250 288 173 – – – – – –<br />

FSH 2) 315 350 330 215 – – – – – –<br />

355 400 385 250 – – – – – –<br />

400 450 420 273 – – – – – –<br />

450 500 470 306 – – – – – –<br />

FSJ 2) 500 500 520 338 – – – – – –<br />

560 600 580 377 – – – – – –<br />

630 700 650 423 – – – – – –<br />

The rated output currents in bold apply for the standard pulse frequency.<br />

1) Rated power based on the base-load current I L .<br />

The base-load current I L is based on the duty cycle for low overload (LO).<br />

2) In the factory setting, these converters start at a pulse frequency of 4 kHz<br />

and reduce it automatically under load to the associated required frequencies.<br />

As the load decreases, the pulse frequency increases automatically<br />

up to 4 kHz. The values of the rated currents apply to a pulse frequency of<br />

2 kHz and are reached at any time by automatic adaptation of the output<br />

pulse frequency.<br />

2/48 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Characteristic curves<br />

Ambient temperature<br />

Frame sizes FSA to FSG:<br />

• Variant PROFINET, EthernNet/IP:<br />

Permissible output current<br />

100<br />

%<br />

90<br />

80<br />

70<br />

92.5<br />

79.25<br />

-20 -10 0 10 20 °C 30 40 45 50 55 60<br />

(-4) (14) (32) (50) (68)(°F)(86)<br />

(104) (122) (140)<br />

Ambient temperature<br />

Permissible output current as a function of ambient temperature for<br />

SINAMICS G120X, frame sizes FSA to FSG, for low overload (LO)<br />

• Variants PROFIBUS DP and USS, Modbus RTU,<br />

BACnet MS/TP:<br />

Permissible<br />

output current<br />

100<br />

%<br />

92.5<br />

90<br />

80<br />

70<br />

66<br />

-20 -10 0 10 20 °C 30 40 45 50 55 60<br />

(-4) (14) (32) (50) (68)(°F)(86)<br />

(104) (122) (140)<br />

Ambient temperature<br />

Permissible output current as a function of ambient temperature for SIN-<br />

AMICS G120X, frame sizes FSA to FSG, for low overload (LO)<br />

G_D011_EN_00572<br />

G_D011_EN_00598<br />

Installation altitude<br />

Frame sizes FSA to FSJ:<br />

Permissible output current<br />

100<br />

%<br />

90<br />

80<br />

70<br />

60<br />

0 1000 2000 3000 m 4000<br />

(3281) (6562) (9843) (ft) (13124)<br />

Installation altitude above sea level<br />

Permissible output current as a function of installation altitude for<br />

SINAMICS G120X for low overload (LO)<br />

The connected motors, power elements and components must<br />

be considered separately.<br />

Permissible line supplies as a function of the installation altitude<br />

• Installation altitude up to 2000 m (6562 ft) above sea level<br />

- Connection to every supply system permitted for the<br />

converter<br />

• Installation altitudes between 2000 m (6562 ft) and 4000 m<br />

(13124 ft) above sea level<br />

- Connection only to a TN system with grounded neutral point<br />

- TN systems with grounded line conductor are not permitted<br />

- The TN line system with grounded neutral point can also be<br />

supplied using an isolation transformer<br />

- The phase-to-phase voltage does not have to be reduced<br />

When using converters on TN systems with voltages 600 V and<br />

at installation altitudes of 2000 m to 4000 m, the TN line supply<br />

must have a grounded neutral point established using an isolation<br />

transformer.<br />

G_D011_EN_00571<br />

2<br />

Frame sizes FSH and FSJ:<br />

Permissible output current<br />

100<br />

%<br />

90<br />

85<br />

80<br />

70<br />

0<br />

(32)<br />

10 20 30<br />

(50) (68) (86)<br />

G_D011_EN_00573<br />

°C 40 45 50 55 60<br />

(°F) (104)(113)(122)<br />

(131)(140)<br />

Ambient temperature<br />

Permissible output current as a function of ambient temperature for<br />

SINAMICS G120X, frame sizes FSH and FSJ, for low overload (LO)<br />

The operating temperature ranges of the operator panels should<br />

be taken into account. The temperature ranges are specified in<br />

the Technical specifications section under Operator panels.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/49


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Characteristic curves<br />

System operating voltage<br />

200 V converters frame sizes FSA to FSF:<br />

400 V converters frame sizes FSH and FSJ:<br />

110<br />

%<br />

2<br />

Output current<br />

105<br />

100<br />

95<br />

90<br />

85<br />

200 210 220 230 240<br />

V<br />

Input voltage<br />

G_D011_EN_00610<br />

Output current<br />

100<br />

%<br />

95<br />

90<br />

85<br />

80<br />

75<br />

360 380 400 420 440 460 480 V 500<br />

Input voltage<br />

G_D011_EN_00576<br />

Permissible output current as a function of the input voltage for<br />

200-V-SINAMICS G120X converters frame sizes FSA to FSF<br />

400 V converters frame sizes FSA to FSG:<br />

Output power<br />

110<br />

%<br />

105<br />

100<br />

95<br />

90<br />

85<br />

300 380 390 400 415 V 528<br />

Input voltage<br />

Permissible output power as a function of the input voltage for<br />

400-V-SINAMICS G120X converters frame sizes FSA to FSG at 100%<br />

output current in the range of 380 V to 415 V<br />

(the temperature protection of the converter can reduce the current or<br />

pulse frequency above 415 V)<br />

Output power<br />

110<br />

%<br />

105<br />

100<br />

95<br />

90<br />

85<br />

440 450 460 470 480 V 528<br />

Input voltage<br />

Permissible output power as a function of the input voltage for<br />

400-V-SINAMICS G120X converters frame sizes FSA to FSG at 100%<br />

output current in the range of 440 V to 480 V<br />

(the temperature protection of the converter can reduce the current or<br />

pulse frequency above 480 V)<br />

Further information is available in the manual on the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

G_D011_EN_00612<br />

G_D011_EN_00611<br />

Permissible output current as a function of input voltage for 400 V<br />

SINAMICS G120X converters, frame sizes FSH and FSJ, for low overload<br />

(LO)<br />

600 V converters frame sizes FSA to FSG:<br />

Output power<br />

100<br />

%<br />

95<br />

90<br />

85<br />

80<br />

75<br />

72<br />

70<br />

500 510 530 550 570 590 610 630 650 670 V 690<br />

Input voltage<br />

Permissible output power as a function of input voltage for<br />

600-V-SINAMICS G120X converters frame sizes FSA to FSG at 100%<br />

output current in the range of 500 V to 690 V<br />

Further information is available in the manual on the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

600 V converters frame sizes FSH and FSJ:<br />

Output current<br />

100<br />

%<br />

95<br />

91<br />

85<br />

80<br />

75<br />

70<br />

480 500 520 540 560 580 600 620 640 660 V 690<br />

Input voltage<br />

Permissible output current as a function of input voltage for 600 V<br />

SINAMICS G120X converters, frame sizes FSH and FSJ, for low<br />

overload (LO)<br />

G_D011_EN_00613<br />

G_D011_EN_00578<br />

2/50 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


f<br />

f<br />

f<br />

© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

■ Dimensional drawings<br />

39 160 150 160<br />

60.5 200 290 200<br />

(1.54) (6.3) (5.91) (6.3)<br />

(2.4) (7.87) (11.42) (7.87)<br />

Ø Ø Ø<br />

c<br />

G_D011_EN_00594<br />

b<br />

a<br />

g<br />

Drill<br />

pattern<br />

FSA<br />

to FSG<br />

d<br />

e<br />

Drill pattern<br />

FSH<br />

e<br />

Drill pattern<br />

FSJ<br />

e<br />

2<br />

Principle dimension drawing and drill pattern for SINAMICS G120X<br />

Frame<br />

size<br />

Dimensions<br />

in mm (inches)<br />

a<br />

(width)<br />

FSA 73<br />

(2.87)<br />

FSB 100<br />

(3.94)<br />

FSC 140<br />

(5.51)<br />

FSD 200<br />

(7.87)<br />

FSE 275<br />

(10.83)<br />

FSF 305<br />

(12.01)<br />

FSG 305<br />

(12.01)<br />

FSH 548<br />

(21.57)<br />

FSJ 801<br />

(31.54)<br />

b<br />

(height)<br />

232<br />

(9.13)<br />

275<br />

(10.83)<br />

295<br />

(11.61)<br />

472<br />

(18.58)<br />

551<br />

(21.69)<br />

709<br />

(27.91)<br />

999<br />

(39.33)<br />

1696<br />

(66.77)<br />

1621<br />

(63.82)<br />

Drilling dimensions<br />

in mm (inches)<br />

49 225 225<br />

60.5 345 345<br />

(1.93) (8.86) (8.86)<br />

(2.38) (13.58) (13.58)<br />

c d e f g With screws<br />

(depth) 1) (plus washers<br />

and nuts)<br />

209<br />

(8.23)<br />

209<br />

(8.23)<br />

209<br />

(8.23)<br />

239<br />

(9.41)<br />

239<br />

(9.41)<br />

360<br />

(14.17)<br />

360<br />

(14.17)<br />

393<br />

(15.47)<br />

393<br />

(15.47)<br />

55<br />

(2.17)<br />

80<br />

(3.15)<br />

118<br />

(4.65)<br />

170<br />

(6.69)<br />

230<br />

(9.06)<br />

270<br />

(10.63)<br />

265<br />

(10.43)<br />

see<br />

above<br />

see<br />

above<br />

221.5<br />

(8.72)<br />

265<br />

(10.43)<br />

283<br />

(11.14)<br />

430<br />

(16.93)<br />

509<br />

(20.04)<br />

680<br />

(26.77)<br />

970.5<br />

(38.21)<br />

1419<br />

(55.87)<br />

1399<br />

(55.<strong>08</strong>)<br />

5.5<br />

(0.22)<br />

7<br />

(0.28)<br />

7<br />

(0.28)<br />

15<br />

(0.59)<br />

11<br />

(0.43)<br />

16.6<br />

(0.65)<br />

18.5<br />

(0.73)<br />

21<br />

(0.83)<br />

21<br />

(0.83)<br />

9<br />

(0.35)<br />

10<br />

(0.39)<br />

11<br />

(0.43)<br />

15<br />

(0.59)<br />

22.5<br />

(0.89)<br />

17.5<br />

(0.69)<br />

20<br />

(0.79)<br />

see<br />

above<br />

see<br />

above<br />

5<br />

(0.2)<br />

5<br />

(0.2)<br />

5.5<br />

(0.22)<br />

6<br />

(0.24)<br />

6.5<br />

(0.26)<br />

8.5<br />

(0.33)<br />

12<br />

(0.47)<br />

20<br />

(0.79)<br />

20<br />

(0.79)<br />

Mounting Cooling clearance 2)<br />

in mm (inches)<br />

4 × M4 80<br />

(3.15)<br />

4 × M4 80<br />

(3.15)<br />

4 × M5 80<br />

(3.15)<br />

4 × M5 300<br />

(11.81)<br />

4 × M6 300<br />

(11.81)<br />

4 × M8 300<br />

(11.81)<br />

4 × M10 300<br />

(11.81)<br />

7 × M8 0<br />

(0)<br />

7 × M8 0<br />

(0)<br />

top bottom front<br />

100<br />

(3.94)<br />

100<br />

(3.94)<br />

100<br />

(3.94)<br />

350<br />

(13.78)<br />

350<br />

(13.78)<br />

350<br />

(13.78)<br />

350<br />

(13.78)<br />

250<br />

(9.84)<br />

250<br />

(9.84)<br />

0<br />

(0)<br />

0<br />

(0)<br />

0<br />

(0)<br />

0<br />

(0)<br />

0<br />

(0)<br />

0<br />

(0)<br />

0<br />

(0)<br />

100<br />

(3.94)<br />

100<br />

(3.94)<br />

■ More information<br />

Compact Installation Instructions are supplied in hard copy<br />

form in German and <strong>English</strong> with every SINAMICS G120X.<br />

Further documentation, such as the operating instructions, is<br />

available free on the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

Detailed information on the SINAMICS G120X infrastructure<br />

converters for HVAC/Water/Wastewater, including the latest<br />

technical documentation (brochures, tutorials, dimensional<br />

drawings, certificates and operating instructions), is available on<br />

the Internet at:<br />

www.siemens.com/sinamics-g120x<br />

and is also available via the Drive Technology Configurator (DT<br />

Configurator) on the Internet.<br />

The DT Configurator can be found in the Siemens Industry Mall<br />

at the following address:<br />

www.siemens.com/dt-configurator<br />

1) Increased depth for frame sizes FSA to FSG:<br />

• When the operator panel is plugged on, the depth increases<br />

by 9 mm (0.35 in)<br />

• When SINAMICS G120 Smart Access is plugged on, the depth increases<br />

by 7 mm (0.28 in)<br />

• When the I/O Extension Module is plugged on, the depth increases<br />

by 27 mm (1.06 in)<br />

- when, in addition, the operator panel is plugged on, the depth<br />

increases by a further 11.8 mm (0.46 in)<br />

- when, in addition, SINAMICS G120 Smart Access is plugged on, the<br />

depth increases by a further 9.8 mm (0.39 in)<br />

2) The converters in frame sizes FSA to FSG can be mounted side by side.<br />

A side clearance of 1 mm (0.04 in) is recommended for tolerance-related<br />

reasons. A side clearance of 30 mm (1.18 in) is required between the converters<br />

for frame sizes FSH and FSJ.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/51


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > Operator panels<br />

■ Overview<br />

Operator panel IOP-2 and IOP-2 Handheld Intelligent Operator Panel BOP-2 Basic Operator Panel<br />

Description<br />

2<br />

Possible applications<br />

Quick commissioning<br />

without expert knowledge<br />

High degree of operator<br />

friendliness and intuitive operation<br />

Minimization of maintenance times<br />

Thanks to the high-contrast color display, menu-based operation<br />

and the wizards, commissioning of the standard <strong>drives</strong> is easy.<br />

Application wizards guide the user through the commissioning<br />

of important applications such as pumps, fans, compressors,<br />

or conveyor systems.<br />

• Can be mounted directly on the converter<br />

• Can be mounted in a <strong>control</strong> cabinet door using a door<br />

mounting kit (achievable degree of protection is IP55/<br />

UL Type 12 enclosure)<br />

• Environmental class/harmful chemical substances Class 3C3<br />

acc. to IEC 60721-3-3: 2002<br />

• Available as handheld version<br />

• The following languages are integrated in the IOP-2:<br />

<strong>English</strong>, German, French, Italian, Spanish, Portuguese,<br />

Dutch, Swedish, Finnish, Russian, Czech, Polish, Turkish,<br />

Chinese Simplified<br />

• Standard commissioning using the clone function<br />

• For quicker access, the parameter block names can be<br />

directly entered respectively changed on the IOP-2 using<br />

the virtual keyboard.<br />

• User-defined parameter list with a reduced number of<br />

self-selected parameters<br />

• Simple commissioning of standard applications using<br />

Quick Startup and Advanced Startup; it is not necessary to know<br />

the parameter structure<br />

• Simple local commissioning using the handheld version<br />

• Commissioning is possible largely without documentation<br />

• Intuitive navigation by operating with a sensor <strong>control</strong> field<br />

• Graphic color display to show status values such as pressure<br />

or flow rate in the form of scalar values, bar-type diagrams, or<br />

trend displays<br />

• Status display with freely selectable units to specify physical<br />

values<br />

• Direct manual operation of the drive – you can simply toggle<br />

between the automatic and manual modes<br />

• Simple cloning of specific settings of the IOP-2 user interface.<br />

• Diagnostics using plain text display, can be used locally on-site<br />

without documentation<br />

• The support function is used to determine the drive data for the<br />

Power Module, Control Unit and IOP-2 and makes this available<br />

as a two-dimensional code (data matrix/QR code)<br />

• Easily upgradable to new functional status via USB interface<br />

Commissioning of standard <strong>drives</strong> is easy with the<br />

menu-prompted dialog on a 2-line display. Simultaneous<br />

display of the parameter and parameter value,<br />

as well as parameter filtering, means that basic<br />

commissioning of a drive can be performed easily<br />

and, in most cases, without a printed parameter list.<br />

• Can be mounted directly on the converter<br />

• Can be mounted in the <strong>control</strong> cabinet door using a<br />

door mounting kit (achievable degree of protection<br />

is IP55/UL Type 12)<br />

• Environmental class/harmful chemical substances<br />

Class 3C3 acc. to IEC 60721-3-3: 2002<br />

• Standard commissioning using the clone function<br />

• 2-line display for showing up to 2 process values<br />

with text<br />

• Status display of predefined units<br />

• Direct manual operation of the drive – you can<br />

simply toggle between the automatic and manual<br />

modes<br />

• Diagnostics with menu prompting with 7-segment<br />

display<br />

2/52 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > IOP-2 Intelligent Operator Panel<br />

■ Overview<br />

IOP-2 Intelligent Operator Panel<br />

Updating the IOP-2<br />

The IOP-2 can be updated and expanded using the integrated<br />

USB interface.<br />

Data to support future drive systems can be transferred from<br />

the PC to the IOP-2. Further, the USB interface allows user<br />

languages and simple setup processes that will become available<br />

in the future to be subsequently downloaded and the firmware<br />

to be updated for the IOP-2 1) .<br />

The IOP-2 is supplied with power via the USB interface during an<br />

update.<br />

IOP-2 Handheld<br />

2<br />

IOP-2 Intelligent Operator Panel<br />

The Intelligent Operator Panel IOP-2 is a very user-friendly and<br />

powerful operator panel for the SINAMICS G120,<br />

SINAMICS G120C, SINAMICS G120P, SINAMICS G120X,<br />

SINAMICS G110D, SINAMICS G120D, SINAMICS G110M and<br />

SIMATIC ET 200pro FC-2.<br />

The IOP-2 supports both newcomers and drive experts. Thanks<br />

to the membrane keyboard with a central sensor <strong>control</strong> field,<br />

high-contrast color displays, menu-based operation and simple<br />

setup processes, which do not require special drive know-how,<br />

it is easy to commission <strong>drives</strong>. The updated IOP-2 (from V2.3)<br />

offers a new concept, which allows faster and easier commissioning<br />

of the drive.<br />

The Quick Startup provides with an overview of the basic parameters<br />

required to commission and operate the drive in a few<br />

minutes.<br />

Advanced Startup supports easier commissioning of more complex<br />

applications and provides the parameters on one screen,<br />

thus eliminating the need to switch between different areas<br />

within the IOP-2.<br />

Advanced Setup provides with a list of categories that needs to<br />

be checked and that guides the user by highlighting the status<br />

icons of categories, which have been altered by the user.<br />

Furthermore, a drive can be essentially commissioned without<br />

having to use a printed parameter list – as the parameters are<br />

displayed in plain text, and explanatory help texts and the parameter<br />

filtering functions are provided.<br />

The status screen allows the graphical visualization of two process<br />

values and the numerical visualization of four process values.<br />

Process values can also be displayed in technological<br />

units.<br />

The IOP-2 supports standard commissioning of identical <strong>drives</strong>.<br />

For this purpose, a parameter list can be copied from a converter<br />

into the IOP-2 and downloaded into other drive units of the<br />

same type as required.<br />

The IOP-2 can be installed in <strong>control</strong> cabinet doors using the<br />

optionally available door mounting kit.<br />

IOP-2 Handheld<br />

A handheld version of the IOP-2 can be ordered for mobile use.<br />

In addition to the IOP-2, it includes a housing with rechargeable<br />

batteries, a charging unit, an RS232 connecting cable, and a<br />

USB cable. The charging unit is supplied with connector<br />

adapters for Europe, the US and UK. When the batteries are<br />

fully charged, the operating time is up to 10 hours.<br />

To connect the IOP-2 Handheld to SINAMICS G110D,<br />

SINAMICS G120D, SINAMICS G110M and<br />

SIMATIC ET 200pro FC-2, the RS232 connecting cable with<br />

optical interface is required in addition.<br />

1) Information on updates for the IOP-2 is available at https://support.industry.siemens.com/cs/document/67273266<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/53


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > IOP-2 Intelligent Operator Panel<br />

2<br />

■ Selection and ordering data<br />

Description<br />

IOP-2 Intelligent Operator Panel<br />

For use with<br />

SINAMICS G120<br />

SINAMICS G120C<br />

SINAMICS G120P<br />

SINAMICS G120X<br />

SINAMICS G110D<br />

SINAMICS G120D<br />

SINAMICS G110M<br />

SIMATIC ET 200pro FC-2<br />

Operating languages: <strong>English</strong>, German,<br />

French, Italian, Spanish, Portuguese,<br />

Dutch, Swedish, Finnish, Russian, Czech,<br />

Polish, Turkish, Chinese Simplified<br />

IOP-2 Handheld<br />

For use with<br />

SINAMICS G120<br />

SINAMICS G120C<br />

SINAMICS G120P<br />

SINAMICS G120X<br />

SINAMICS G110D<br />

SINAMICS G120D<br />

SINAMICS G110M<br />

SIMATIC ET 200pro FC-2<br />

Included in the scope of delivery:<br />

•IOP-2<br />

• Handheld housing<br />

• Rechargeable batteries (4 × AA)<br />

• Charging unit (international)<br />

• RS232 connecting cable 1)<br />

3 m (9.84 ft) long,<br />

can be used in combination with<br />

SINAMICS G120<br />

SINAMICS G120C<br />

SINAMICS G120P<br />

SINAMICS G120X<br />

•USB cable<br />

1 m (3.28 ft) long<br />

Accessories<br />

Door mounting kit<br />

For mounting an operator panel in<br />

<strong>control</strong> cabinet doors with sheet steel<br />

thicknesses of 1 ... 3 mm (0.04 in ... 0.12 in)<br />

Degree of protection IP55<br />

Included in the scope of delivery:<br />

•Seal<br />

• Mounting material<br />

• Connecting cable<br />

5 m (16.4 ft) long,<br />

also supplies voltage to the IOP-2<br />

directly via the converter<br />

RS232 connecting cable<br />

2.5 m (8.20 ft) long,<br />

with optical interface for connecting the<br />

IOP-2 Handheld to<br />

SINAMICS G110D<br />

SINAMICS G120D<br />

SINAMICS G110M<br />

SIMATIC ET 200pro FC-2<br />

Article No.<br />

6SL3255-0AA00-4JA2<br />

6SL3255-0AA00-4HA1<br />

6SL3256-0AP00-0JA0<br />

3RK1922-2BP00<br />

■ Benefits<br />

• New device design<br />

- Intuitive user interface – membrane keyboard with central<br />

sensor <strong>control</strong> field<br />

- High-contrast color display with a range of display options<br />

- IOP-2 device design open for future functional expansions<br />

(e.g. device functions, commissioning setups, languages)<br />

- Easily upgradable to new functional status via USB interface<br />

• Commissioning<br />

- Simple commissioning via Quick Startup and Advanced<br />

Startup<br />

- Quick Startup allows easy and fast access to all basic<br />

parameters required for the commissioning of simple<br />

applications<br />

- Advanced Startup provides the parameters necessary for<br />

the commissioning of more complex applications and eliminates<br />

the need to switch between different areas of the IOP-2<br />

- I/O Setup supports quick and easy configuration of the<br />

digital and analog inputs and outputs<br />

- Fieldbus Setup allows easy configuration of the Ethernet/IP<br />

and PROFINET interface protocols<br />

- Fast standard commissioning of converters thanks to the<br />

cloning function<br />

- For quicker access, the parameter data set names can be<br />

directly entered respectively changed on the IOP-2 using the<br />

virtual keyboard. Extended help functions support the user<br />

during commissioning.<br />

- Simple local commissioning on-site using the handheld<br />

version<br />

• Operator <strong>control</strong> and monitoring<br />

- Simple, individual local drive <strong>control</strong> (start/stop, setpoint<br />

value specification, change in direction of rotation)<br />

- Application-specific scenarios such as operator concepts<br />

with additional external operating elements can be<br />

implemented easily<br />

- Simple cloning of specific settings of the IOP-2 user<br />

interface, such as status screen, language settings, lighting<br />

duration, date/time settings, parameter backup mode and<br />

“My Parameters” – settings made once can such be easily<br />

transferred to many further IOP-2 Intelligent Operator Panels<br />

• Diagnostics<br />

- Rapid diagnostics thanks to on-site plain text display<br />

- Integrated plain text help function for local display and<br />

resolution of fault messages<br />

• Support function<br />

- Used to determine the drive data for the Power Module,<br />

Control Unit and IOP-2 (article number, serial number,<br />

firmware version, error statuses) and makes this available as<br />

a two-dimensional code (data matrix/QR code)<br />

- Allows easy contact with Customer Support via a data<br />

matrix/QR code generated on the IOP-2<br />

- Quick access via mobile devices (e.g. smartphones, tablets)<br />

to product information, documentation, FAQs, contact<br />

persons via a two-dimensional code generated on the IOP-2<br />

(data matrix/QR code)<br />

- Scanning and evaluating of the two-dimensional data matrix<br />

code using the Industry Online Support app<br />

(https://support.industry.siemens.com/cs/ww/en/sc/2067),<br />

see also:<br />

https://support.industry.siemens.com/cs/document/109748340<br />

1) For use in conjunction with SINAMICS G110D, SINAMICS G120D,<br />

SINAMICS G110M and SIMATIC ET 200pro FC-2, the RS232 connecting<br />

cable with optical interface is required (Article No.: 3RK1922-2BP00).<br />

The cable must be ordered separately.<br />

2/54 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > IOP-2 Intelligent Operator Panel<br />

■ Integration<br />

Using the IOP-2 with the converters<br />

Plugging the IOP-2<br />

onto the converter<br />

(Voltage supply via<br />

converter)<br />

Door mounting of the<br />

IOP-2 with the door<br />

mounting kit<br />

(Voltage supply via<br />

converter. For this<br />

purpose, the IOP-2<br />

must be connected<br />

up by means of the<br />

connecting cable<br />

supplied with the<br />

door mounting kit.)<br />

Mobile use of the<br />

IOP-2 Handheld<br />

(supplied from<br />

rechargeable batteries)<br />

Door mounting<br />

• SINAMICS G120<br />

with CU230P-2,<br />

CU240E-2 or<br />

CU250S-2<br />

• SINAMICS G120C<br />

• SINAMICS G120P<br />

with CU230P-2<br />

• SINAMICS G120X<br />

–<br />

–<br />

<br />

• SINAMICS G110D<br />

• SINAMICS G120D<br />

• SINAMICS G110M<br />

• SIMATIC ET 200pro<br />

FC-2<br />

(RS232 connecting<br />

cable with optical<br />

interface required,<br />

article number<br />

3RK1922-2BP00)<br />

Using the optionally available door mounting kit, an operator<br />

panel can be simply mounted in a <strong>control</strong> cabinet door with<br />

just a few manual operations. In the case of door mounting,<br />

the IOP-2 Operator Panel achieves degree of protection<br />

IP55/UL Type 12 enclosure.<br />

Bolt<br />

Door mounting bracket<br />

Door plate<br />

Sealing sleeve<br />

Operator<br />

Panel<br />

■ Technical specifications<br />

Display<br />

• Resolution<br />

Operator panel<br />

Operating languages<br />

Ambient temperature<br />

• During transport<br />

and storage<br />

• During operation<br />

Humidity<br />

Degree of protection<br />

Dimensions<br />

(H × W × D)<br />

IOP-2<br />

6SL3255-0AA00-4JA2<br />

IOP-2 Handheld<br />

6SL3255-0AA00-4HA1<br />

High-contrast color display, a variety of<br />

display options<br />

320 × 240 pixels<br />

Membrane keyboard with central sensor<br />

<strong>control</strong> field<br />

<strong>English</strong>, German, French, Italian, Spanish,<br />

Portuguese, Dutch, Swedish, Finnish, Russian,<br />

Czech, Polish, Turkish, Chinese Simplified<br />

-40...+70°C<br />

(-40 ... +158 °F)<br />

For direct mounting<br />

on the converter:<br />

0...50°C<br />

(32 ... 122 °F)<br />

For installation with<br />

door mounting kit:<br />

0...55°C<br />

(32 ... 131 °F)<br />

-20 ... +55 °C<br />

(-4 ... +131 °F)<br />

0...40°C<br />

(32 ... 104 °F)<br />

Relative humidity < 95 %, non-condensing<br />

For direct mounting IP20<br />

on the converter:<br />

IP20<br />

For installation with<br />

door mounting kit:<br />

IP55, UL Type 12<br />

enclosure<br />

106.86 × 70 ×<br />

19.65 mm<br />

(4.21 × 2.76 × 0.77 in)<br />

195.04 × 70 ×<br />

37.58 mm<br />

(7.68 × 2.76 × 1.48 in)<br />

Weight, approx. 0.134 kg (0.3 lb) 0.724 kg (1.6 lb)<br />

Compliance with CE, RCM, cULus, EAC, KC-REM-S49-SINAMICS<br />

standards<br />

Environmental class<br />

in operation<br />

• Harmful chemical Class 3C3 acc. to IEC 60721-3-3: 2002<br />

substances<br />

2<br />

Fixing screws<br />

D type<br />

G_D011_EN_00531<br />

Door mounting kit with plugged-on IOP-2<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/55


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > BOP-2 Basic Operator Panel<br />

■ Overview<br />

■ Selection and ordering data<br />

2<br />

Description<br />

BOP-2 Basic Operator Panel<br />

Accessories<br />

Door mounting kit<br />

For mounting an operator panel in<br />

<strong>control</strong> cabinet doors with sheet steel<br />

thicknesses of 1 ... 3 mm (0.04 ... 0.12 in)<br />

Degree of protection IP55<br />

Included in the scope of delivery:<br />

•Seal<br />

• Mounting material<br />

• Connecting cable<br />

5 m/16.4 ft long, also supplies voltage<br />

to the operator panel directly via the<br />

converter<br />

Article No.<br />

6SL3255-0AA00-4CA1<br />

6SL3256-0AP00-0JA0<br />

BOP-2 Basic Operator Panel<br />

The BOP-2 Basic Operator Panel can be used to commission<br />

<strong>drives</strong>, monitor <strong>drives</strong> in operation and input individual<br />

parameter settings.<br />

Commissioning of standard <strong>drives</strong> is easy with the menuprompted<br />

dialog on a 2-line display. Simultaneous display of the<br />

parameter and parameter value, as well as parameter filtering,<br />

means that basic commissioning of a drive can be performed<br />

easily and, in most cases, without a printed parameter list.<br />

The <strong>drives</strong> are easily <strong>control</strong>led manually using directly assigned<br />

navigation buttons. The BOP-2 has a dedicated switchover<br />

button to switch from automatic to manual mode.<br />

Diagnostics can easily be performed on the connected converter<br />

by following the menus.<br />

Up to two process values can be numerically visualized<br />

simultaneously.<br />

BOP-2 supports standard commissioning of identical <strong>drives</strong>.<br />

For this purpose, a parameter list can be copied from a converter<br />

into the BOP-2 and when required, downloaded into other<br />

drive units of the same type.<br />

The operating temperature of the BOP-2 is 0 °C ... 50 °C<br />

(32 °F ... 122 °F).<br />

The environmental class/harmful chemical substances of BOP-2<br />

is class 3C3 acc. to IEC 60721-3-3: 2002.<br />

■ Benefits<br />

• Shorten commissioning times – Easy commissioning of<br />

standard <strong>drives</strong> using basic commissioning wizards (setup)<br />

• Minimize standstill times – Fast detection and rectification of<br />

faults (Diagnostics)<br />

• Greater transparency in the process – The status display of<br />

the BOP-2 makes process variable monitoring easy<br />

(Monitoring)<br />

• Direct mounting on the converter<br />

• User-friendly user interface:<br />

- Easy navigation using clear menu structure and clearly<br />

assigned <strong>control</strong> keys<br />

- Two-line display<br />

2/56 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > Memory cards<br />

■ Overview<br />

■ Selection and ordering data<br />

Description<br />

SINAMICS SD card<br />

512 MB, empty<br />

Article No.<br />

6SL3054-4AG00-2AA0<br />

2<br />

SINAMICS SD memory card<br />

The parameter settings for a converter can be stored on the<br />

SINAMICS SD memory card. When service is required, e.g. after<br />

the converter has been replaced and the data have been downloaded<br />

from the memory card, the drive system is immediately<br />

ready for use again.<br />

• Parameter settings can be written from the memory card to the<br />

converter or saved from the converter to the memory card.<br />

• Up to 100 parameter sets can be stored.<br />

• The memory card supports standard commissioning without<br />

the use of an operator panel such as the IOP-2 or BOP-2.<br />

• If firmware is stored on the memory card, the firmware can be<br />

upgraded/downgraded during power-up.<br />

Note:<br />

The memory card is not required for operation and does not<br />

have to remain inserted.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/57


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > SINAMICS G120 Smart Access<br />

■ Overview<br />

■ Technical specifications<br />

2<br />

SINAMICS G120 Smart Access<br />

It is also easy and convenient to commission and operate the<br />

SINAMICS G120, SINAMICS G120C and SINAMICS G120X<br />

converters of firmware V4.7 SP6 and higher using the web server<br />

module SINAMICS G120 Smart Access and a connected<br />

smartphone, tablet or laptop.<br />

■ Benefits<br />

• Wireless commissioning, operation and diagnostics via<br />

mobile device or laptop thanks to the optional<br />

SINAMICS G120 Smart Access<br />

• Easy access to the converter in difficult-to-access areas<br />

• Intuitive user interface and commissioning wizard<br />

• Free choice of terminal devices as the web server works with<br />

all common web browsers, such as iOS, Android, Windows,<br />

Linux and Mac OS<br />

■ Function<br />

• Commissioning using commissioning wizard<br />

• Setting and saving parameters<br />

• Testing motor in JOG mode<br />

• Monitoring of converter data<br />

• Quick diagnostics<br />

• Saving the settings and restoring to factory settings<br />

■ Selection and ordering data<br />

Operating system<br />

Languages<br />

Ambient temperature<br />

• During storage and transport<br />

• During operation<br />

Humidity<br />

Degree of protection<br />

Dimensions<br />

•Width<br />

•Height<br />

•Depth<br />

Weight, approx.<br />

Compliance with standards<br />

■ Integration<br />

SINAMICS G120<br />

Smart Access<br />

6SL3255-0AA00-5AA0<br />

iOS, Android, Windows, Linux,<br />

Mac OS<br />

Support of six languages:<br />

<strong>English</strong>, French, German,<br />

Italian, Spanish, Chinese<br />

-40...+70°C<br />

(-40 ... +158 °F)<br />

0 ... 50 °C (32 ... 122 °F)<br />

if the Smart Access is plugged<br />

directly into the converter<br />

< 95 %, non-condensing<br />

Depending on the degree of<br />

protection of the converter,<br />

max. IP55/UL Type 12<br />

enclosure<br />

70 mm (2.76 in)<br />

1<strong>08</strong>.9 mm (4.29 in)<br />

17.3 mm (0.68 in)<br />

0.<strong>08</strong> kg (0.18 lb)<br />

CE, FCC, SRRC, WPC,<br />

ANATEL, BTK<br />

Description<br />

SINAMICS G120 Smart Access<br />

For wireless commissioning, operation and<br />

diagnostics of the following converters<br />

using a smartphone, tablet or laptop<br />

• SINAMICS G120C<br />

• SINAMICS G120 together with the<br />

CU230P-2 and CU240E-2 Control Units<br />

(without fail-safe versions)<br />

• SINAMICS G120X<br />

Article No.<br />

6SL3255-0AA00-5AA0<br />

SINAMICS G120X frame size FSD with plugged-on<br />

SINAMICS G120 Smart Access<br />

The optional SINAMICS G120 Smart Access is simply plugged<br />

onto the converter and is available for the following converters of<br />

firmware V4.7 SP6 and higher.<br />

• SINAMICS G120C<br />

• SINAMICS G120 together with the CU230P-2 and CU240E-2<br />

Control Units (without fail-safe versions)<br />

• SINAMICS G120X<br />

2/58 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

■ Overview<br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > SINAMICS CONNECT 300 IoT Gateway<br />

The optional SINAMICS CONNECT 300 IoT Gateway is suitable<br />

for SINAMICS V20, SINAMICS G120C, SINAMICS G120,<br />

SINAMICS G120X, MICROMASTER 420, MICROMASTER 430<br />

and MICROMASTER 440 converters.<br />

The converter system is thus fit for digitalization. Thanks to its full<br />

integration in the SINAMICS CONNECT 300 system, data from<br />

up to eight converters can be acquired and transferred to the<br />

MindSphere cloud solution. The MindSphere application<br />

"Analyze MyDrives" facilitates the evaluation of data – tailored to<br />

individual customer needs. This simplifies the acquisition and<br />

evaluation of converter conditions.<br />

Scope of delivery:<br />

• One SINAMICS CONNECT 300 IoT Gateway device with one<br />

mounted DC terminal block for connecting to 9 V DC to<br />

36 V DC power supply<br />

• Quick Installation Guide in <strong>English</strong> language<br />

For more technical information see<br />

https://support.industry.siemens.com/cs/us/en/ps/25436<br />

2<br />

SINAMICS CONNECT 300 IoT Gateway<br />

Example: SINAMICS G120 with connected<br />

SINAMICS CONNECT 300 IoT Gateway<br />

■ Benefits<br />

• The integrated web server with its setup wizard ensures a simple<br />

and easy commissioning of the device.<br />

• The standard MindSphere tools assure a smooth integration of<br />

the <strong>drives</strong> into the MindSphere world.<br />

• Eight RS232 ports to connect 8 different <strong>drives</strong> simultaneously<br />

• Up to 40 drive parameters can be transferred to MindSphere<br />

at the same time. The dedicated parameters can be selected<br />

via a search functionality.<br />

• Point-to-point connection via RS232 prevents that additional<br />

load is put to the drive <strong>control</strong>ler and to the fieldbus communication.<br />

• Continuous display of the actual MindSphere connectivity<br />

state in the web server<br />

• Comprehensive connection to MindSphere on AWS,<br />

MindSphere on AZURE and MindSphere on ALIBABA Cloud<br />

• 500 MByte data buffer secures the data from loss if the<br />

Internet connection is interrupted.<br />

• Comprehensive service management of the device via the<br />

integrated web server (CA certificates, license management,<br />

firmware updates, automatic validation of the configuration,<br />

etc.)<br />

• Easy top hat rail mounting<br />

• Perfect system harmonization with Analyze My Drives<br />

MindSphere App<br />

• Secure communication to MindSphere by using<br />

https-tunnelling<br />

■ Selection and ordering data<br />

Description<br />

SINAMICS CONNECT 300 IoT<br />

Gateway<br />

for connecting the following<br />

converters to the MindSphere cloud:<br />

• SINAMICS V20<br />

• SINAMICS G120C<br />

• SINAMICS G120<br />

• SINAMICS G120X<br />

• MICROMASTER 420 /<br />

MICROMASTER 430 /<br />

MICROMASTER 440<br />

NEW NEU<br />

Article No.<br />

6SL3255-0AG30-0AA0<br />

Example: SINAMICS G120X with connected<br />

SINAMICS CONNECT 300 IoT Gateway<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/59


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > SINAMICS G120X I/O Extension Module<br />

2<br />

■ Overview<br />

SINAMICS G120X I/O Extension Module<br />

The SINAMICS G120X I/O Extension Module increases the number<br />

of I/O terminals of the converter and therefore allows for<br />

additional converter <strong>control</strong> functionalities. It also allows for the<br />

connection to an operator panel or the SINAMICS G120 Smart<br />

Access.<br />

The optional SINAMICS G120X I/O Extension Module has 2 DI,<br />

2 AO, 4 DO (relay), and up to 2 Pt1000/Ni1000 temperature<br />

sensors can be directly connected.<br />

Notes:<br />

The SINAMICS G120X I/O Extension Module is only supported<br />

for SINAMICS G120X converters with FS codes 02 02 (FSA to<br />

FSG) / 02 (FSH and FSJ) and firmware V1.01.<br />

The FS code can be found on the rating plate of the converter.<br />

■ Selection and ordering data<br />

Description<br />

SINAMICS G120X I/O Extension<br />

Module<br />

for the direct connection of<br />

Pt1000/Ni1000 temperature sensors<br />

NEW NEU<br />

Article No.<br />

6SL3255-0BE00-0AA0<br />

■ More information<br />

Further information and documentation is available on the<br />

Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

■ Technical specifications<br />

Article No.<br />

6SL3255-0BE00-0AA0<br />

Analog inputs<br />

Number of analog inputs 2<br />

Design of the sensor to detect the<br />

ambient temperature connectable<br />

Connectable conductor cross-section at<br />

the analog input<br />

AWG number as coded connectable<br />

conductor cross-section at the analog<br />

input<br />

Input current<br />

Analog outputs<br />

2 analog inputs for connecting temperature<br />

sensors Pt1000/Ni1000.<br />

One of them can be used as an<br />

analog input.<br />

0.5 ... 1.5 mm²<br />

21 ... 16<br />

0...20mA<br />

Number of analog outputs 2<br />

Analog outputs Type<br />

Non-isolated output<br />

Connectable conductor cross-section at 0.5 ... 1.5 mm²<br />

the analog output<br />

AWG number as coded connectable 21 ... 16<br />

conductor cross-section at the analog<br />

output<br />

Output voltage at analog output 0...10V<br />

Output current at analog output 0...20mA<br />

Digital inputs<br />

Number of digital inputs 2<br />

Connectable conductor cross-section at 0.5 ... 1.5 mm²<br />

the digital inputs<br />

AWG number as coded connectable 21 ... 16<br />

conductor cross-section at the digital<br />

inputs<br />

Digital inputs Input voltage for signal<br />

"0" "1"<br />

Digital inputs Input voltage for signal<br />

"1" "0"<br />

Input voltage at digital input maximum<br />

Digital outputs<br />

11 V<br />

5V<br />

30 V<br />

Number of digital outputs 4<br />

Connectable conductor cross-section at 1.5 mm²<br />

the digital outputs maximum<br />

AWG number as coded connectable 16<br />

conductor cross section at the digital<br />

outputs maximum<br />

Output current at digital output<br />

Mechanical data<br />

Width<br />

Depth<br />

Height<br />

2A<br />

71 mm<br />

27 mm<br />

117 mm<br />

2/60 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

■ Overview<br />

Supplementary system components > Push-through mounting frames for frame sizes FSA to FSG<br />

For push-through installation of frame sizes FSD to FSG, installation<br />

handles are available for insertion without the need for a<br />

lifting device.<br />

SINAMICS G120X frame size FSC with IOP-2 Intelligent Operator Panel<br />

and push-through mounting frame<br />

The optional push-through mounting frame is used to install a<br />

SINAMICS G120X converter, frame sizes FSA to FSG, in a <strong>control</strong><br />

cabinet with the heat sink outside the <strong>control</strong> cabinet. The<br />

converter achieves degree of protection IP20/UL Open Type<br />

with push-through installation.<br />

■ Selection and ordering data<br />

Description<br />

Article No.<br />

Push-through mounting frames<br />

for SINAMICS G120X<br />

• Frame size FSA 6SL3261-6GA00-0BA0<br />

• Frame size FSB 6SL3261-6GB00-0BA0<br />

• Frame size FSC 6SL3261-6GC00-0BA0<br />

• Frame size FSD 6SL3261-6GD00-0BA0<br />

• Frame size FSE 6SL3261-6GE00-0BA0<br />

• Frame size FSF 6SL3261-6GF00-0BA0<br />

• Frame size FSG 6SL3261-6GG00-0BA0<br />

Accessories<br />

Installation handles<br />

6SL3200-0SM22-0AA0<br />

for SINAMICS G120X<br />

frame sizes FSD to FSF<br />

2<br />

Supplementary system components<br />

> IP21 top covers for frame sizes FSA to FSG<br />

■ Overview<br />

■ Dimensional drawings<br />

a<br />

d<br />

c<br />

b<br />

Ø<br />

c<br />

G_D011_XX_00590<br />

SINAMICS G120X frame size FSC with IOP-2 Intelligent Operator Panel<br />

and IP21 top cover<br />

Using the optional IP21 top cover, SINAMICS G120X converters<br />

in frame sizes FSA to FSG achieve degree of protection 21. With<br />

wall mounting, the IP21 top cover has to be installed above the<br />

converter.<br />

■ Selection and ordering data<br />

Description<br />

Article No.<br />

IP21 top covers<br />

for SINAMICS G120X<br />

• Frame size FSA 6SL3266-1PA00-0BA0<br />

• Frame size FSB 6SL3266-1PB00-0BA0<br />

• Frame sizes FSC and FSD 6SL3266-1PD00-0BA0<br />

• Frame size FSE 6SL3266-1PE00-0BA0<br />

• Frame sizes FSF and FSG 6SL3266-1PF00-0BA0<br />

Frame<br />

size<br />

Dimensions<br />

in mm (inches)<br />

a<br />

(width)<br />

FSA 120<br />

(4.72)<br />

FSB 160<br />

(6.3)<br />

FSC 260<br />

(10.24)<br />

FSD 260<br />

(10.24)<br />

FSE 335<br />

(13.19)<br />

FSF, FSG 365<br />

(14.37)<br />

b c<br />

(height) (depth)<br />

25<br />

(0.98)<br />

25<br />

(0.98)<br />

29<br />

(1.14)<br />

29<br />

(1.14)<br />

29<br />

(1.14)<br />

29<br />

(1.14)<br />

306<br />

(12.05)<br />

306<br />

(12.05)<br />

323<br />

(12.72)<br />

323<br />

(12.72)<br />

323<br />

(12.72)<br />

443<br />

(17.44)<br />

Drilling<br />

dimensions<br />

in mm (inches)<br />

Cooling clearance<br />

d between converter<br />

and IP21 top cover<br />

80<br />

(3.15)<br />

118<br />

(4.65)<br />

170<br />

(6.69)<br />

170<br />

(6.69)<br />

230<br />

(9.06)<br />

270<br />

(10.63)<br />

4.5<br />

(0.18)<br />

5.5<br />

(0.22)<br />

6<br />

(0.24)<br />

6<br />

(0.24)<br />

6<br />

(0.24)<br />

6<br />

(0.24)<br />

100<br />

(3.94)<br />

100<br />

(3.94)<br />

100<br />

(3.94)<br />

300<br />

(11.81)<br />

300<br />

(11.81)<br />

300<br />

(11.81)<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/61


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > Wiring adapter for frame size FSG<br />

■ Overview<br />

■ Integration<br />

2<br />

Wiring adapter for frame size FSG<br />

The wiring adapter enables optimal and space-saving wiring of<br />

frame size FSG for SINAMICS G120 PM240-2 Power Modules<br />

and SINAMICS G120X.<br />

Up to four smaller cables (with a cross section of 120 mm2 each)<br />

can be routed with the adapter for connection to the line supply<br />

and to the motor. All cables can be connected on the underside<br />

of the adapter, which allows for easy and space-saving wiring.<br />

The scope of delivery of the wiring adapter includes contacts,<br />

nuts, a cover and various small components.<br />

SINAMICS G120 frame size FSG with wiring adapter (and cable outlet)<br />

SINAMICS G120X frame size FSG with wiring adapter (and cable outlet)<br />

Further documentation on SINAMICS G120 is available free on<br />

the Internet at:<br />

www.siemens.com/sinamics-g120/documentation<br />

Further documentation on SINAMICS G120X is available free on<br />

the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

■ Selection and ordering data<br />

Description<br />

Wiring adapter for frame size FSG<br />

for optimal and space-saving wiring<br />

of SINAMICS G120 PM240-2 Power<br />

Modules and SINAMICS G120X<br />

NEW NEU<br />

Article No.<br />

6SL3266-2HG00-0BA0<br />

2/62 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Supplementary system components > Installation kit for line-side cable connection, left, for frame size FSH<br />

■ Overview<br />

■ Selection and ordering data<br />

Description<br />

Installation kit for line-side cable<br />

connection, left<br />

for SINAMICS G120X<br />

frame size FSH<br />

Article No.<br />

6SL3366-1LH00-0PA0<br />

2<br />

Installation kit for line-side cable connection, left, for SINAMICS G120X,<br />

frame size FSH<br />

This installation kit allows supply cables of the SINAMICS G120X<br />

converter, frame size FSH, to be connected alternatively on the<br />

left-hand side of the converter. The converter can thus be installed<br />

higher in the <strong>control</strong> cabinet, allowing more efficient use<br />

of the available cabinet space. In many cases, use of this installation<br />

kit also helps in the implementation of effective cabinet<br />

cooling.<br />

Spare parts<br />

> FPI board for frame sizes FSH and FSJ<br />

■ Overview<br />

■ Selection and ordering data<br />

The FPI board (freely-programmable interface board) is available<br />

as a spare part for the SINAMICS G120X converter, frame<br />

Description<br />

FPI board<br />

sizes FSH and FSJ. This is an interface board between Control<br />

for SINAMICS G120X<br />

Unit and Power Module with additional customer terminals<br />

frame sizes FSH and FSJ<br />

(X9, X41).<br />

Article No.<br />

6SL3200-0SP05-0AA0<br />

Spare parts<br />

> PSB board for frame sizes FSH and FSJ<br />

■ Overview<br />

The PSB board (power supply board) is available as a spare part<br />

for the SINAMICS G120X converter, frame sizes FSH and FSJ.<br />

This is an internal power supply with ±24 V for the electronics<br />

and 56 V for a power unit fan.<br />

■ Selection and ordering data<br />

Description<br />

PSB board<br />

for SINAMICS G120X<br />

frame sizes FSH and FSJ<br />

Article No.<br />

6SL3200-0SP06-0AA0<br />

Spare parts<br />

> Current transformers for frame sizes FSH and FSJ<br />

■ Overview<br />

■ Selection and ordering data<br />

Current transformers are available as spare parts for the<br />

Description<br />

Article No.<br />

SINAMICS G120X converter, frame sizes FSH and FSJ. These<br />

Current transformers<br />

are 2000 A or 1000 A current transformers for measuring the motor<br />

current at the device output. The current transformers are<br />

for SINAMICS G120X<br />

used for motor <strong>control</strong> and converter protection.<br />

• 2000 A for frame size FSJ 6SL3200-0SE01-0AA0<br />

• 1000 A for frame sizes FSH and FSJ 6SL3200-0SE02-0AA0<br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/63


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Spare parts > Spare parts kit for Control Unit<br />

■ Overview<br />

■ Selection and ordering data<br />

2<br />

The spare parts kit contains small parts for the SINAMICS G120X<br />

Control Unit:<br />

Included in the scope of delivery:<br />

• 1 STO connecting plug for frame sizes FSA to FSC<br />

• 3 replacement doors for the Control Unit<br />

• 4 I/O terminals<br />

• 1 screw for RS485 terminal<br />

• 1 blanking cover<br />

• Label set<br />

Description<br />

Spare parts kit for Control Unit<br />

for SINAMICS G120X<br />

Article No.<br />

6SL3200-0SK10-0AA0<br />

Spare parts<br />

> Shield connection kit for Control Unit<br />

■ Overview<br />

■ Selection and ordering data<br />

A shield connection kit for the Control Unit is supplied with the Description<br />

SINAMICS G120X converters, frame sizes FSD to FSG. It is advisable<br />

to install the supplied shield connection kit for EMC-com-<br />

Shield connection kit for<br />

Control Unit<br />

pliant configuration of the converter. This shield connection kit for SINAMICS G120X<br />

can be ordered as a spare part.<br />

frame sizes FSD to FSG<br />

The shield connection kit offers optimum shield connection and<br />

strain relief for all signal and communication cables.<br />

The kit contains the following:<br />

• a matching shield connection plate<br />

• all of the necessary connecting and retaining elements for<br />

mounting<br />

Article No.<br />

6SL3264-1EA00-0YA0<br />

Spare parts<br />

> Shield connection kits for Power Module<br />

■ Overview<br />

A shield connection kit is supplied with the SINAMICS G120X<br />

■ Selection and ordering data<br />

Description<br />

Article No.<br />

converters, frame sizes FSA to FSG. It is advisable to install the Shield connection kits for<br />

supplied shield connection kit for EMC-compliant configuration Power Module<br />

of the converter. These shield connection kits can be ordered as<br />

spare parts.<br />

Please observe the notes included in the operating instructions<br />

for the SINAMICS G120X converters, frame sizes FSH and FSJ.<br />

www.siemens.com/sinamics-g120x/documentation<br />

for SINAMICS G120X<br />

• Frame size FSA<br />

• Frame size FSB<br />

• Frame size FSC<br />

• Frame size FSD<br />

6SL3262-1AA01-0DA0<br />

6SL3262-1AB01-0DA0<br />

6SL3262-1AC01-0DA0<br />

6SL3262-1AD01-0DA0<br />

• Frame size FSE 6SL3262-1AE01-0DA0<br />

• Frame size FSF 6SL3262-1AF01-0DA0<br />

• Frame size FSG 6SL3262-1AG01-0DA0<br />

Spare parts<br />

> Small parts assembly set for frame sizes FSD to FSG<br />

■ Overview<br />

A small parts assembly set can be ordered for SINAMICS<br />

G120 Power Modules PM240-2, SINAMICS G120C and<br />

SINAMICS G120X, degree of protection IP20. It contains the<br />

following parts:<br />

• Cable entries for frame sizes FSD to FSG<br />

• 2 × 2 pin STO mating connector<br />

• 1 set of warning labels in 30 languages<br />

■ Selection and ordering data<br />

Description<br />

Small parts assembly set<br />

for SINAMICS G120 Power Modules<br />

PM240-2, SINAMICS G120C and<br />

SINAMICS G120X<br />

degree of protection IP20,<br />

frame sizes FSD to FSG<br />

Article No.<br />

6SL3200-0SK<strong>08</strong>-0AA0<br />

2/64 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Spare parts > Terminal cover kits for frame sizes FSD to FSG<br />

■ Overview<br />

■ Selection and ordering data<br />

The terminal cover kit includes a replacement cover for the<br />

connecting terminals.<br />

Terminal cover kits, which are suitable for the following<br />

converters in frame sizes FSD to FSG, are available:<br />

• SINAMICS G120 PM240-2 Power Modules<br />

• SINAMICS G120 PM250 Power Modules<br />

• SINAMICS G120C<br />

• SINAMICS G120X<br />

Description<br />

Terminal cover kits<br />

for SINAMICS G120 PM240-2<br />

Power Modules<br />

• for frame size FSD<br />

• for frame size FSE<br />

• for frame size FSF<br />

• for frame size FSG<br />

Terminal cover kits<br />

for SINAMICS G120 PM250<br />

Power Modules<br />

Article No.<br />

6SL3200-0SM13-0AA0<br />

6SL3200-0SM14-0AA0<br />

6SL3200-0SM15-0AA0<br />

6SL3200-0SM16-0AA0<br />

2<br />

• for frame sizes FSD and FSE<br />

6SL3200-0SM11-0AA0<br />

• for frame size FSF<br />

6SL3200-0SM12-0AA0<br />

Terminal cover kits<br />

for SINAMICS G120C<br />

• for frame size FSD<br />

6SL3200-0SM13-0AA0<br />

• for frame size FSE<br />

6SL3200-0SM14-0AA0<br />

• for frame size FSF<br />

6SL3200-0SM15-0AA0<br />

Terminal cover kits<br />

for SINAMICS G120X<br />

• for frame size FSD<br />

6SL3200-0SM13-0AA0<br />

• for frame size FSE<br />

6SL3200-0SM14-0AA0<br />

• for frame size FSF<br />

6SL3200-0SM15-0AA0<br />

• for frame size FSG<br />

6SL3200-0SM16-0AA0<br />

Spare parts<br />

> Fan units<br />

■ Overview<br />

The fans of the SINAMICS G120X converters are designed for<br />

extra long service life. For special requirements, replacement<br />

fans are available that can be exchanged quickly and easily.<br />

■ Selection and ordering data<br />

Description<br />

External fan units<br />

for SINAMICS G120X<br />

• Frame size FSA<br />

• Frame size FSB<br />

• Frame size FSC<br />

• Frame size FSD<br />

• Frame size FSE<br />

• Frame size FSF<br />

• Frame size FSG<br />

• Frame sizes FSH and FSJ<br />

Internal fan unit<br />

for SINAMICS G120X<br />

• Frame sizes FSH and FSJ<br />

Article No.<br />

6SL3200-0SF52-0AA0<br />

6SL3200-0SF53-0AA0<br />

6SL3200-0SF54-0AA0<br />

6SL3200-0SF15-0AA0<br />

6SL3200-0SF16-0AA0<br />

6SL3200-0SF17-0AA0<br />

6SL3200-0SF18-0AA0<br />

6SL3300-0SF01-0AA0<br />

6SL3200-0SF50-0AA0<br />

Spare parts<br />

> Control Units<br />

■ Overview<br />

Control units are available as spare parts for the SINAMICS<br />

G120X convertes frame sizes FSD to FSJ.<br />

■ Selection and ordering data<br />

Description<br />

Control Units<br />

for SINAMICS G120X<br />

frame sizes FSD to FSJ<br />

• USS, Modbus RTU, BACnet MS/TP<br />

• PROFINET, EtherNet/IP<br />

•PROFIBUS DP<br />

Article No.<br />

6SL3200-0SC10-0BA0<br />

6SL3200-0SC10-0FA0<br />

6SL3200-0SC10-0PA0<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

2/65


© Siemens <strong>2020</strong><br />

SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater<br />

0.75 kW to 630 kW (1 hp to 700 hp)<br />

Notes<br />

2<br />

2/66 Siemens D 31.5 · March <strong>2020</strong>


Engineering tools<br />

© Siemens <strong>2020</strong><br />

3<br />

SINAMICS SELECTOR App<br />

Mobile selection guide for frequency<br />

converters<br />

Siemens has developed the SINAMICS<br />

SELECTOR app as a practical tool for<br />

finding article numbers for your SINAMICS<br />

converter in the power range from<br />

0.12 kW to 630 kW quickly and easily.<br />

Whether for SINAMICS V20, SINAMICS<br />

G120C, SINAMICS G120P, SINAMICS<br />

G120X or SINAMICS G120: The app will<br />

provide you with the correct article numbers<br />

conveniently.<br />

How does it work? Simply select your application,<br />

the frequency converter you require,<br />

the rated power and device options<br />

as well as the necessary accessories.<br />

Then you can save your selection and<br />

send it by email. The preselection serves<br />

as the basis for an order specification with<br />

the dealer/Siemens.<br />

You will find free downloads for Android<br />

and iOS here:<br />

www.siemens.com/sinamics-selector<br />

SINAMICS ASSISTANT app<br />

The error code function of the<br />

SINAMICS ASSISTANT app helps you to<br />

identify and rectify errors. Just enter the<br />

error code of your frequency converter<br />

and the app shows you what sort of error it<br />

is and how you can rectify it.<br />

This app also recalculates for you the<br />

frequency (Hz) of a frequency converter<br />

into the speed to be set on the motor (rpm)<br />

or vice versa.<br />

In addition this app offers you a support<br />

page on which you can get in touch<br />

straight away with the right contact person<br />

in your region if you have any questions.<br />

Furthermore, video information is available<br />

to you free of charge, e.g. on installation<br />

and commissioning of the<br />

SINAMICS G120 frequency converter.<br />

You will find the free downloads for<br />

Android and for iOS at the following link:<br />

www.siemens.com/sinamics-assistant<br />

3/2 Drive Technology Configurator<br />

3/3 SIMARIS planning tools for systems with<br />

SINAMICS <strong>drives</strong><br />

3/5 SinaSave energy efficiency tool<br />

3/6 SIZER for Siemens Drives<br />

engineering tool<br />

3/7 SINAMICS web server for<br />

SINAMICS G120X via<br />

SINAMICS G120 Smart Access<br />

Security information<br />

Siemens provides products and solutions<br />

with industrial security functions that<br />

support the secure operation of plants,<br />

systems, machines and networks.<br />

In order to protect plants, systems, machines<br />

and networks against cyber threats,<br />

it is necessary to implement – and continuously<br />

maintain – a holistic, state-of-the-art<br />

industrial security concept. Siemens’<br />

products and solutions constitute one<br />

element of such a concept.<br />

Customers are responsible for preventing<br />

unauthorized access to their plants,<br />

systems, machines and networks. Such<br />

systems, machines and components<br />

should only be connected to an enterprise<br />

network or the internet if and to the extent<br />

such a connection is necessary and only<br />

when appropriate security measures<br />

(e.g. firewalls and/or network segmentation)<br />

are in place.<br />

For additional information on industrial<br />

security measures that may be implemented,<br />

please visit<br />

https://www.siemens.com/industrialsecurity<br />

Siemens’ products and solutions undergo<br />

continuous development to make them<br />

more secure. Siemens strongly recommends<br />

that product updates are applied as<br />

soon as they are available and that the<br />

latest product versions are used. Use of<br />

product versions that are no longer supported,<br />

and failure to apply the latest updates<br />

may increase customer’s exposure<br />

to cyber threats.<br />

To stay informed about product updates,<br />

subscribe to the Siemens Industrial<br />

Security RSS Feed under<br />

https://www.siemens.com/industrialsecurity<br />

Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Engineering tools<br />

Drive Technology Configurator<br />

■ Overview<br />

■ More information<br />

The Drive Technology Configurator (DT Configurator) helps you Online access to the Drive Technology Configurator<br />

to configure the optimum drive technology products for your<br />

application – starting with gear units, motors, converters as well<br />

More information about the Drive Technology Configurator is<br />

as the associated options and components and ending with<br />

available on the Internet at<br />

<strong>control</strong>lers, software licenses and connection systems. Whether<br />

www.siemens.com/dtconfigurator<br />

with little or detailed knowledge of products: preselected product<br />

groups, deliberate navigation through selection menus and<br />

direct product selection through entry of the article number<br />

support quick, efficient and convenient configuration.<br />

In addition, comprehensive documentation comprising technical<br />

data sheets, 2D dimensional drawings/3D CAD models,<br />

operating instructions, certificates, etc. can be selected in the<br />

DT Configurator. Immediate ordering is possible by simply transferring<br />

a parts list to the shopping cart of the Industry Mall.<br />

3<br />

Drive Technology Configurator for efficient drive<br />

configuration with the following functions<br />

• Quick and easy configuration of drive products and<br />

associated components – gear units, motors, converters,<br />

<strong>control</strong>lers, connection systems<br />

• Configuration of drive systems for pumps, fans and<br />

compressor applications from 1 kW to 2.6 MW<br />

• Retrievable documentation for configured products and<br />

components, such as<br />

- Data sheets in up to 9 languages in PDF or RTF format<br />

- 2D dimensional drawings/3D CAD models in various formats<br />

- Terminal box drawing and terminal connection diagram<br />

- Operating instructions<br />

- Certificates<br />

- Start-up calculation for SIMOTICS motors<br />

-EPLAN macros<br />

• Support with retrofitting in conjunction with Spares On Web<br />

(www.siemens.com/sow)<br />

• Ability to order products directly through the Siemens<br />

Industry Mall<br />

Access to the Drive Technology Configurator<br />

The Drive Technology Configurator can be called up without<br />

registration and without a login:<br />

www.siemens.com/dt-configurator<br />

3/2 Siemens D 31.5 · March <strong>2020</strong><br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

Engineering tools<br />

SIMARIS planning tools for systems with SINAMICS <strong>drives</strong><br />

■ Overview<br />

Electrical Planning: Simplified by Electrical Design<br />

Software!<br />

Electrical planning of power distribution systems in functional<br />

and industrial buildings has never been easy and is now more<br />

complex than ever. The electrical calculation software tools<br />

SIMARIS design for dimensioning and SIMARIS project for determination<br />

of the distribution boards’ space requirements support<br />

technical planners with the electrical planning process with<br />

SINAMICS <strong>drives</strong>.<br />

Supported SINAMICS <strong>drives</strong>:<br />

• SINAMICS G120, SINAMICS G120D, SINAMICS G120X<br />

• SINAMICS G110D, SINAMICS G110M<br />

• SINAMICS G130, SINAMICS G150<br />

SIMARIS planning tools for systems with SINAMICS <strong>drives</strong> > SIMARIS design<br />

■ Overview<br />

SIMARIS design is a planning tool for quick and effective network<br />

calculation and dimensioning of power distribution for nonresidential<br />

and industrial buildings.<br />

Starting in the planning phase, the entire electrical circuit required<br />

for the project can be structured and dimensioned on the<br />

basis of real products. For this purpose, the network structure is<br />

initially set up based on the stored modules for infeeds, couplings,<br />

distributors and branch circuits. It is also possible to reuse<br />

stored favorites, such as those processed for previous similar<br />

projects. Suitable components and distribution systems are<br />

then automatically selected from the product database stored in<br />

SIMARIS design based on the selected project-specific parameters<br />

and technical data. This precludes the extra costs so often<br />

incurred in the implementation phase as a result of systems that<br />

have not been correctly coordinated.<br />

Any configuration of electric power distribution is subject to frequent<br />

change and adaptation, not only in the planning phase,<br />

but also in the implementation phase. SIMARIS design makes it<br />

easy to incorporate such changes in the supply concept and to<br />

automatically check their reliability in terms of sound engineering<br />

practice and the currently applicable standards.<br />

SIMARIS design professional, a program version available for a<br />

fee, offers additional useful functions. It can be used to carry out<br />

and also document selectivity analyses, essential for safety<br />

power supply systems. There is also the option of analyzing and<br />

optimizing the energy efficiency of the planned network.<br />

The versatile output variants enable precise documentation of<br />

the project structure and of the calculated data suitable for every<br />

phase of a project.<br />

There is also the option of exporting the project data. This enables<br />

further processing of the planned project in SIMARIS project,<br />

and thus also supports and facilitates system planning.<br />

■ Benefits<br />

• Reduction in processing overhead for projects<br />

• Dimensioning of electrical networks on the basis of real products<br />

according to sound engineering practice and the currently<br />

applicable standards (VDE, IEC)<br />

• Automatic selection of the correct components from medium<br />

voltage through to interfacing of the load from the stored product<br />

database, i.e. no detailed knowledge of products and systems<br />

required<br />

• Open definition of the types of mains operation and switching<br />

states<br />

• Calculation of the short circuit current, load flow, voltage drop<br />

and energy balance<br />

• Incorporation of the required person, short circuit and overload<br />

protection<br />

• Option of factoring in any necessary functional endurance<br />

• Display and dimensioning of cable and busbar trunking systems<br />

for power conveyance and distribution<br />

• High planning reliability coupled with flexibility in the planning<br />

and implementation process<br />

• Tracking changes via change index possible<br />

• Simple adaptation in the case of application changes or expansions<br />

• Option for saving frequently required modules in the favorites<br />

library<br />

• Output of the created network diagram, as well as detailed<br />

parts lists and data lists<br />

• Incorporation of country-specific product portfolios<br />

• Comprehensive documentation of planning results with simple<br />

data transfer (Office, CAD etc.)<br />

■ Application<br />

SIMARIS design is a software tool for the network calculation<br />

and dimensioning of power distribution for non-residential and<br />

industrial buildings. Whether for a shopping center, a hospital or<br />

production facilities - with SIMARIS design you can reduce the<br />

overhead required for the overall planning of power distribution<br />

systems and hence the time spent on the selection and dimensioning<br />

of equipment.<br />

■ More information<br />

For further information and available downloads, please go to:<br />

www.siemens.com/simarisdesign<br />

If you have any other questions, please do not hesitate to contact<br />

our Customer Support Center:<br />

Phone: +49 70 00 7 46 27 47<br />

Email: technical-assistance@siemens.com<br />

3<br />

Siemens D 31.5 · March <strong>2020</strong><br />

3/3


© Siemens <strong>2020</strong><br />

Engineering tools<br />

SIMARIS planning tools for systems with SINAMICS <strong>drives</strong> > SIMARIS project<br />

3<br />

■ Overview<br />

SIMARIS project is a planning tool for fast calculation of space<br />

requirements and electrical power distribution system budgets<br />

for non-residential and industrial buildings, and for generating<br />

specifications automatically.<br />

The following is determined in SIMARIS project based on the<br />

pre-defined project structure and the basic technical specifications<br />

selected:<br />

• For medium-voltage switchboards: selection of the required<br />

system and the required fields, then presentation of a front<br />

view with dimensions.<br />

• Following selection of the system for transformers, the required<br />

quantity must be selected. Selected transformers are<br />

presented as a parts list.<br />

• For low-voltage switchboards and distribution boards: selection<br />

of the required protection devices and switching devices<br />

per system. The most suitable distribution system is determined<br />

automatically based on the list of distribution devices<br />

thus created. It is then equipped with the devices and presented<br />

graphically in an automatically generated front view<br />

that includes dimensions.<br />

• Following selection of the system for busbar trunking systems<br />

the length is specified and the additionally required components<br />

are selected, e.g. infeeds, junction units and tap-off<br />

units. All the resulting components are listed in a parts list.<br />

Detailed information about Siemens devices or their article numbers<br />

is not needed because SIMARIS project makes the selection<br />

automatically on the basis of the parameters entered.<br />

For each item of switchboard or each distribution board,<br />

SIMARIS project takes the wiring, <strong>control</strong> and measurement etc.<br />

into account.<br />

A system plan drawn up in SIMARIS design can also be imported<br />

into SIMARIS project, which means that selecting devices<br />

becomes redundant and SIMARIS project builds up the<br />

project structure automatically.<br />

Convenient output versions are available to document the results,<br />

including the automatic generation of specifications for the<br />

planned systems.<br />

Typical versions of a system planned in SIMARIS project can be<br />

saved and repeatedly integrated in new projects from the favorites<br />

library. Automatically created systems can also be subsequently<br />

optimized or changed. This is particularly relevant if<br />

planning becomes more detailed and the budget needs to be reinforced<br />

as a result.<br />

For detailed calculation of costs - on an up-to-date and regional<br />

basis - and for more project support, please contact your<br />

Siemens representative.<br />

■ Benefits<br />

• Intuitive and easy to operate<br />

• Automatic selection and placement of matching distribution<br />

systems<br />

• Fast determination of the space requirements and cost of<br />

power distribution plants<br />

• End-to-end planning, from medium-voltage switchgear assemblies,<br />

transformers, low-voltage switchgear and busbar<br />

trunking systems right through to the distribution boards<br />

• Simple adaptation of project planning with increasing clarification<br />

of implementation requirements, but also in the event of<br />

application changes or expansions<br />

• Saving planned systems for similar projects individually in<br />

the favorites library and importing them from there into new<br />

projects<br />

• Option of factoring in functional endurance for busbar<br />

systems<br />

• Convenient output versions for documentation, such as<br />

graphic views, lists and specifications<br />

• Projects created in SIMARIS design can also be imported<br />

■ Application<br />

SIMARIS project is suitable for the fast determination of the<br />

space requirements and cost of electrical power distribution in<br />

all industrial and non-residential buildings and for the automatic<br />

generation of specifications. From shopping centers to hospitals<br />

and production buildings – with SIMARIS project it is possible to<br />

reduce the amount of work required for the overall planning of<br />

power distribution systems and hence the time spent on selecting<br />

and dimensioning the necessary equipment.<br />

■ More information<br />

For further information and available downloads, please go to:<br />

www.siemens.com/simarisproject<br />

If you have any other questions, please do not hesitate to contact<br />

our Customer Support Center:<br />

Phone: +49 70 00 7 46 27 47<br />

Email: technical-assistance@siemens.com<br />

3/4 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Engineering tools<br />

■ Overview<br />

The SinaSave energy efficiency tool calculates potential energy<br />

savings and amortization times based on your individual conditions<br />

of use and therefore offers practical assistance in making<br />

decisions about investments in energy-efficient technologies.<br />

From SinaSave Version 6.0 and higher, the drive systems to be<br />

compared and the relevant drive component parameters are<br />

displayed graphically. An additional expansion are the numerous<br />

comparison possibilities for different <strong>control</strong> types and comprehensive<br />

product combinations for drive solutions for pump<br />

and fan applications. In addition to SIMOTICS motors and<br />

SINAMICS <strong>drives</strong>, the product portfolio comprises SIRIUS<br />

switching devices, offering a comprehensive range of comparison<br />

possibilities – according to your individual requirements.<br />

SinaSave energy efficiency tool<br />

SinaSave supports the evaluation of the various comparisons of<br />

product and system by<br />

• Displaying the potential savings for energy and energy costs,<br />

as well as CO 2 emissions<br />

• Estimation of the amortization time<br />

• Estimation of the individual total lifecycle costs<br />

• Representation of the system power losses according to<br />

EN 50598-2 for full load and partial load<br />

• Direct comparison of Siemens <strong>drives</strong> with the reference Power<br />

Drive System (PDS) described in EN 50598-2<br />

3<br />

SinaSave offers numerous comparison scenarios:<br />

• Comparison of drive systems for pump and fan applications in<br />

the output range from 0.55 kW (low voltage) to 5.5 MW<br />

(medium voltage) for<br />

- Reactor <strong>control</strong> (fixed speed; motor and switching device)<br />

- Bypass <strong>control</strong> (fixed speed; motor and switching device)<br />

- Speed <strong>control</strong> (variable speed; motor and frequency<br />

converter)<br />

• Comparison and evaluation of standard motors (incl. ignition<br />

protection motors) in different energy efficiency classes<br />

Access to the SinaSave energy efficiency tool<br />

SinaSave can be accessed without the need for registration or<br />

logging in:<br />

www.automation.siemens.com/sinasave<br />

■ More information<br />

For more information about the amortization calculator for<br />

energy-efficient drive systems, visit<br />

www.siemens.com/sinasave<br />

More information about services for energy saving is available<br />

on the Internet at<br />

www.siemens.com/energysaving<br />

Siemens D 31.5 · March <strong>2020</strong><br />

3/5


© Siemens <strong>2020</strong><br />

Engineering tools<br />

3<br />

SIZER for Siemens Drives engineering tool<br />

■ Overview<br />

The following <strong>drives</strong> and <strong>control</strong>s can be engineered in a userfriendly<br />

way using the SIZER for Siemens Drives engineering<br />

tool:<br />

• SIMOTICS low-voltage motors, including servo geared motors<br />

• SIMOGEAR geared motors<br />

• SINAMICS low-voltage drive systems<br />

• Motor starters<br />

• SINUMERIK CNC<br />

• SIMOTION Motion Control <strong>control</strong>ler<br />

• SIMATIC <strong>control</strong>ler<br />

It provides support when selecting the technologies involved in<br />

the hardware and firmware components required for a drive<br />

task. SIZER for Siemens Drives covers the full range of operations<br />

required to configure a <strong>complete</strong> drive system, from basic<br />

single <strong>drives</strong> to demanding multi-axis applications.<br />

SIZER for Siemens Drives supports all of the engineering steps<br />

in one workflow:<br />

• Configuring the power supply<br />

• Designing the motor and gearbox, including calculation of<br />

mechanical transmission elements<br />

• Configuring the drive components<br />

• Compiling the required accessories<br />

• Selecting the line-side and motor-side power options, e.g.<br />

cables, filters, and reactors<br />

When SIZER for Siemens Drives was being designed, particular<br />

importance was placed on a high degree of usability and a<br />

universal, function-based approach to the drive application. The<br />

extensive user guidance makes it easy to use the tool. Status<br />

information keeps you continually informed about the progress<br />

of the configuration process.<br />

The drive configuration is saved in a project. In the project, the<br />

components and functions used are displayed in a hierarchical<br />

tree structure.<br />

The project view permits the configuration of drive systems and<br />

the copying/inserting/modifying of <strong>drives</strong> already configured.<br />

The configuration process produces the following results:<br />

• A parts list of the required components (export to Excel, use<br />

of the Excel data sheet for import to SAP)<br />

• Technical specifications of the system<br />

• Characteristic curves<br />

• Comments on system reactions<br />

• Mounting arrangement of drive and <strong>control</strong> components and<br />

dimensional drawings of motors<br />

• Energy requirements of the configured application<br />

These results are displayed in a results tree and can be reused<br />

for documentation purposes.<br />

Support is provided by the technological online help menu:<br />

• Detailed technical specifications<br />

• Information about the drive systems and their components<br />

• Decision-making criteria for the selection of components<br />

• Online help in <strong>English</strong>, French, German, Italian, Chinese and<br />

Japanese<br />

System requirements<br />

• PG or PC, PentiumTM III min. 800 MHz<br />

(recommended > 1 GHz)<br />

• 512 MB RAM (1 GB recommended)<br />

• At least 2 GB of free hard disk space<br />

• An additional 100 MB of free hard disk space on Windows<br />

system drive<br />

• Screen resolution 1024 × 768 pixels<br />

• Operating system:<br />

- Windows 7 (32/64-bit) Professional, Enterprise, Ultimate,<br />

Home<br />

- Windows 8.1 (32/64-bit) Professional, Enterprise, Ultimate,<br />

Home<br />

- Microsoft Office 20<strong>03</strong>/2007/2010/2013/2016<br />

- Windows 365<br />

- Microsoft Internet Explorer V8.0<br />

- Microsoft .NET Framework 2.0<br />

-OpenGL2.1<br />

- Windows 10 (64-bit) Professional, Enterprise<br />

• Microsoft Internet Explorer from V5.5 SP2<br />

■ More information<br />

The SIZER for Siemens Drives engineering tool is available free<br />

on the Internet at<br />

www.siemens.com/sizer<br />

3/6 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Engineering tools<br />

SINAMICS web server for SINAMICS G120X via SINAMICS G120 Smart Access<br />

■ Overview<br />

Web server for efficient commissioning, diagnostics and<br />

maintenance<br />

SINAMICS G120X<br />

with IOP-2<br />

SINAMICS G120<br />

Smart Access<br />

SINAMICS G120X with IOP-2 and SINAMICS G120 Smart Access<br />

Thanks to the optionally available SINAMICS G120 Smart<br />

Access, the SINAMICS G210X drive system offers a web server<br />

for efficient commissioning, diagnostics and maintenance options.<br />

The web server provides access to a multi-faceted range<br />

of new options for parameter assignment and drive diagnostics<br />

for laptops, tablets and smartphones, including:<br />

• Simple and fast commissioning<br />

• Drive traversing via the <strong>control</strong> panel<br />

• Downloading/uploading a configuration<br />

• Providing a status overview of the drive<br />

• Evaluating warnings and fault messages<br />

• Monitoring and adapting parameter settings<br />

G_D011_EN_00568<br />

■ Benefits<br />

Simple and fast commissioning<br />

• No installation of additional commissioning software<br />

• Standard pages for limit values and settings<br />

• Comprehensive fault diagnosis<br />

Direct language selection<br />

• <strong>English</strong>, German, French, Italian, Spanish, Chinese<br />

Accessibility<br />

• Free choice of terminal devices as the web server works with<br />

all common web browsers, such as iOS, Android, Windows,<br />

Linux and Mac OS<br />

Diagnostic functions<br />

• Quick overview of the current configuration and the state of<br />

the drive<br />

• Understandable diagnostic information and messages, including<br />

the causes of issues and possible remedies, are displayed<br />

in plain text in multiple languages<br />

Freely configurable parameter lists<br />

• Monitoring parameters for diagnostic purposes, for example<br />

for operating personnel<br />

• Adjustment of the parameter lists using filters, parameter<br />

groups and the configuration of personal lists<br />

Access security<br />

• Protection against unauthorized access to the drive<br />

information<br />

■ Application<br />

The web server is ideal for applications in which special commissioning<br />

software or version dependencies are not desired.<br />

Easy commissioning, diagnostics and maintenance are possible<br />

locally, provided appropriate security measures are applied.<br />

3<br />

Siemens D 31.5 · March <strong>2020</strong><br />

3/7


© Siemens <strong>2020</strong><br />

Engineering tools<br />

Notes<br />

3<br />

3/8 Siemens D 31.5 · March <strong>2020</strong>


Services and documentation<br />

© Siemens <strong>2020</strong><br />

4<br />

4/2 Partner<br />

4/3 Industry Services<br />

4/4 Industry Services – Portfolio overview<br />

4/5 Online Support<br />

4/6 Training<br />

4/6 SITRAIN – Digital Industry Academy<br />

4/7 Training courses for<br />

SINAMICS low-voltage converters<br />

4/8 SINAMICS G120X training case<br />

4/9 Control cabinets<br />

4/11 Applications<br />

4/12 Spare parts services<br />

4/12 Spare parts services during the lifecycle<br />

4/12 Delivery of spare parts<br />

4/13 Delivery as exchange product<br />

4/13 Repair<br />

4/14 Product upgrade service<br />

4/14 General overhaul<br />

4/15 Function check<br />

4/15 Return of diagnostic parts<br />

4/16 Stock reduction in spare parts store<br />

4/16 Extended spare part availability<br />

4/17 Spares on Web<br />

4/18 Product Partner – Drives Options<br />

4/19 mySupport documentation<br />

4/20 Documentation<br />

4/20 General documentation<br />

4/21 SINAMICS G120X documentation<br />

Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Partner<br />

Partner at Siemens<br />

4<br />

At your service locally, around the globe for consulting, sales,<br />

training, service, support, spare parts on the entire portfolio of<br />

Digital Industries.<br />

Your partner can be found in our Personal Contacts Database at:<br />

www.siemens.com/automation-contact<br />

You start by selecting<br />

• the required competence,<br />

• products and branches,<br />

• a country and a city<br />

or by a<br />

location search or free text search.<br />

4/2 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Industry Services<br />

■ Overview<br />

Support and<br />

Consulting<br />

Services<br />

Training<br />

Services<br />

Digital Industry<br />

Services<br />

Service<br />

Programs and<br />

Agreements<br />

Spare Parts<br />

Services<br />

Repair<br />

Services<br />

Field and<br />

Maintenance<br />

Services<br />

Retrofit and<br />

Modernization<br />

Services<br />

4<br />

G_DA65_XX_00272b<br />

Keep your business running and shaping your digital future – with Industry Services<br />

Optimizing the productivity of your equipment and operations<br />

can be a challenge, especially with constantly changing market<br />

conditions. Working with our service experts makes it easier.<br />

We understand your industry's unique processes and provide<br />

the services needed so that you can better achieve your business<br />

goals.<br />

You can count on us to maximize your uptime and minimize your<br />

downtime, increasing your operations' productivity and reliability.<br />

When your operations have to be changed quickly to meet a<br />

new demand or business opportunity, our services give you the<br />

flexibility to adapt. Of course, we take care that your production<br />

is protected against cyber threats. We assist in keeping your<br />

operations as energy and resource efficient as possible and reducing<br />

your total cost of ownership. As a trendsetter, we ensure<br />

that you can capitalize on the opportunities of digitalization and<br />

by applying data analytics to enhance decision making: You can<br />

be sure that your plant reaches its full potential and retains this<br />

over the longer lifespan.<br />

You can rely on our highly dedicated team of engineers, technicians<br />

and specialists to deliver the services you need – safely,<br />

professionally and in compliance with all regulations. We are<br />

there for you, where you need us, when you need us.<br />

www.siemens.com/industryservices<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/3


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Industry Services<br />

Industry Services – Portfolio overview<br />

■ Overview<br />

Digital Industry<br />

Services<br />

Digital Industry Services<br />

Digital Industry Services make your industrial<br />

processes transparent to gain improvements in<br />

productivity, asset availability, and energy<br />

efficiency.<br />

Production data is generated, filtered and<br />

translated with intelligent analytics to enhance decision-making.<br />

This is done whilst taking data security into consideration and<br />

with continuous protection against cyber-attack threats.<br />

www.siemens.com/global/en/products/services/industry/<br />

digital-industry-services.html<br />

Repair<br />

Services<br />

Repair Services<br />

Repair Services are offered on-site and in regional<br />

repair centers for fast restoration of faulty<br />

devices’ functionality.<br />

Also available are extended repair services,<br />

which include additional diagnostic and repair<br />

measures, as well as emergency services.<br />

https://support.industry.siemens.com/cs/ww/en/sc/2154<br />

Training<br />

Services<br />

Training Services<br />

From the basics and advanced to specialist<br />

skills, SITRAIN courses provide expertise right<br />

from the manufacturer – and encompass the<br />

entire spectrum of Siemens products and<br />

systems for the industry.<br />

Worldwide, SITRAIN courses are available wherever you need a<br />

training course in more than 170 locations in over 60 countries.<br />

https://support.industry.siemens.com/cs/ww/en/sc/2226<br />

Field and<br />

Maintenance<br />

Services<br />

Field and Maintenance Services<br />

Siemens specialists are available globally to<br />

provide expert field and maintenance services,<br />

including commissioning, functional testing,<br />

preventive maintenance and fault clearance.<br />

All services can be included in customized service<br />

agreements with defined reaction times or fixed maintenance<br />

intervals.<br />

https://support.industry.siemens.com/cs/ww/en/sc/2265<br />

4<br />

Support and<br />

Consulting<br />

Services<br />

Support and Consulting Services<br />

Industry Online Support site for comprehensive<br />

information, application examples, FAQs<br />

and support requests.<br />

Technical and Engineering Support for advice<br />

and answers for all inquiries about functionality,<br />

handling, and fault clearance. The Service Card as<br />

prepaid support for value added services such as Priority Call<br />

Back or Extended Support offers the clear advantage of quick<br />

and easy purchasing.<br />

Information & Consulting Services, e.g. SIMATIC System<br />

Audit; clarity about the state and service capability of your automation<br />

system or Lifecycle Information Services; transparency<br />

on the lifecycle of the products in your plants.<br />

https://support.industry.siemens.com/cs/ww/en/sc/2235<br />

Retrofit and<br />

Modernization<br />

Services<br />

Retrofit and Modernization Services<br />

Provide a cost-effective solution for the expansion<br />

of entire plants, optimization of systems or<br />

upgrading existing products to the latest technology<br />

and software, e.g. migration services for<br />

automation systems.<br />

Service experts support projects from planning through commissioning<br />

and, if desired over the entire extended lifespan, e.g.<br />

Retrofit for Integrated Drive Systems for an extended lifetime of<br />

your machines and plants.<br />

https://support.industry.siemens.com/cs/ww/en/sc/2286<br />

Spare Parts<br />

Services<br />

Spare Parts<br />

Spare Parts Services are available worldwide<br />

for smooth and fast supply of spare parts – and<br />

thus optimal plant availability. Genuine spare<br />

parts are available for up to ten years. Logistic<br />

experts take care of procurement, transport,<br />

custom clearance, storage and order management.<br />

Reliable logistics processes ensure that components<br />

reach their destination as needed.<br />

Since not all spare parts can be kept in stock at all times,<br />

Siemens offers a preventive measure for spare parts provisioning<br />

on the customer's premises with optimized Spare Parts<br />

Packages for individual products, custom-assembled drive<br />

components and entire integrated drive trains – including risk<br />

consulting.<br />

Asset Optimization Services help you design a strategy for<br />

parts supply where your investment and carrying costs are<br />

reduced and the risk of obsolescence is avoided.<br />

https://support.industry.siemens.com/cs/ww/en/sc/2110<br />

Service<br />

Programs and<br />

Agreements<br />

Service Programs and Agreements<br />

A technical Service Program or Agreement<br />

enables you to easily bundle a wide range of<br />

services into a single annual or multi-year<br />

agreement.<br />

You pick the services you need to match your<br />

unique requirements or fill gaps in your organization’s maintenance<br />

capabilities.<br />

Programs and agreements can be customized as KPI-based<br />

and/or performance-based contracts.<br />

https://support.industry.siemens.com/cs/ww/en/sc/2275<br />

4/4 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Industry Services<br />

Online Support<br />

■ Overview<br />

Online Support – fast, intuitive, whenever you want,<br />

wherever you need<br />

Web<br />

support.industry.siemens.com<br />

App<br />

Scan the QR code<br />

for information on<br />

our Online Support<br />

app.<br />

FAQ / Application examples<br />

Information about industrial products, programming and configuration as well as application<br />

examples<br />

4<br />

Technical information<br />

Videos, documentation, manuals, updates, product notes, compatibility tool, certificates, planning data<br />

such as dimensional drawings, product data, 3D models<br />

Forum<br />

Exchange information and experience with other users and experts<br />

Online Support for Siemens Industry Products<br />

Siemens Industry and Online Support with some 1.7 million visitors<br />

per month is one of the most popular web services provided<br />

by Siemens. It is the central access point for comprehensive<br />

technical know-how about products, systems and services for<br />

automation and <strong>drives</strong> applications as well as for process<br />

industries.<br />

In connection with the challenges and opportunities related to<br />

digitalization you can look forward to continued support with<br />

innovative offerings.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/5


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Training<br />

SITRAIN – Digital Industry Academy<br />

4<br />

Time for learning<br />

Today’s demands on our knowledge are every bit as diverse and dynamic as our profession itself. We keep learning more and longer<br />

– for our work, for our career and for ourselves. Advancing digitalization entails new topics and is also changing the way we absorb<br />

and process knowledge. SITRAIN – Digital Industry Academy offers the right source of knowledge here, which we can use anytime<br />

in just the way we need it. The time for learning is now.<br />

Knowledge for every need<br />

<br />

<br />

With its three areas – SITRAIN open, SITRAIN access and<br />

SITRAIN personal – SITRAIN offers you an all-encompassing<br />

range of options for an ongoing expansion of your knowledge<br />

and skills, suited for every type of learner. And SITRAIN uses<br />

advancing digitalization to continuously expand content and<br />

offer new training methods.<br />

Knowledge you can always find<br />

SITRAIN open bundles useful information, worthwhile data and<br />

up-to-date expert knowledge about Siemens products for<br />

industry. Search it anytime, find anything – and always the right<br />

stuff.<br />

Knowledge that gets you ahead<br />

SITRAIN access is learning in the digital age. It offers you<br />

individualized ways to build your knowledge and access to<br />

exclusive digital training courses. Take advantage of sustainable<br />

learning success with a wide range of learning methods.<br />

Improve your skills – whether working in groups with others, or<br />

by yourself. Whenever, wherever and however you need to.<br />

Knowledge you can experience<br />

We all want to learn from the best. And SITRAIN personal’s<br />

training courses let you benefit from our well-practiced trainers’<br />

expert knowledge, along with direct access to our training<br />

equipment. That’s the best way to convey knowledge – whether<br />

at your company or in our training classrooms.<br />

Find<br />

your local<br />

offer here<br />

SITRAIN – Digital Industry Academy<br />

Customer Support Germany<br />

Tel.: +49 911 895-7575<br />

E-Mail: sitrain.digital.industry.academy.de@siemens.com<br />

SITRAIN – Digital Industry Academy<br />

www.siemens.com/sitrain<br />

• SITRAIN open:<br />

www.siemens.com/sitrain-open<br />

• SITRAIN access:<br />

www.siemens.com/sitrain-access<br />

• SITRAIN personal:<br />

www.siemens.com/sitrain-personal<br />

4/6 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Training<br />

Training courses for SINAMICS low-voltage converters<br />

■ Overview<br />

Training courses for SINAMICS drive system<br />

This provides an overview of the training courses available for<br />

the SINAMICS drive system.<br />

The courses are modular in design and are directed at a variety<br />

of target groups as well as individual customer requirements.<br />

The system overview will acquaint decision-makers and sales<br />

personnel with the system very quickly.<br />

The engineering course provides all the information you need to<br />

configure the drive system.<br />

The courses dedicated to diagnostics and servicing, parameterization<br />

and commissioning, communication as well as extended<br />

functions such as Safety Integrated are sure to provide all the<br />

technical knowledge service engineers will need.<br />

All courses contain as many practical exercises as possible to<br />

enable intensive and direct training on the drive system and with<br />

the tools in small groups.<br />

Please also take note of the training options available for<br />

SIMOTICS motors. You will find more information about<br />

course contents and dates in Catalog ITC and on the Internet.<br />

Title Target group Duration Order code<br />

(all courses are available in <strong>English</strong> and German)<br />

Planners,<br />

decision-makers,<br />

sales personnel<br />

Commissioning<br />

engineers,<br />

configuring<br />

Service personnel,<br />

maintenance<br />

technicians<br />

engineers<br />

Courses Fundamentals and overview<br />

SINAMICS and SIMOTICS – Basics of drive technology 5days DR-GAT<br />

SINAMICS and SIMOTICS – System overview – – 3 days DR-SYS<br />

SINAMICS System Overview – – 2 days DR-SN-UEB<br />

Courses SINAMICS S120<br />

Planning and engineering – – 5 days DR-S12-PL<br />

Parameterizing and commissioning – – 5 days DR-S12-PM<br />

Parameterization and commissioning in the TIA – – 5 days DR-S12-PMT<br />

Parameterization Advanced Course – – 5 days DR-S12-PA<br />

Parameterizing and optimizing – – 5 days DR-S12-OPT<br />

Parameterizing Safety Integrated – – 4 days DR-S12-SAF<br />

Diagnostics and service – – 5 days DR-S12-DG<br />

Diagnostics at chassis and cabinet units – 3 days DR-S12-CHA<br />

Courses SINAMICS G120<br />

Planning and engineering – – 2 days DR-G12-PL<br />

Parameterizing and commissioning – – 2 days DR-G12-PM<br />

Parameterization Advanced Course – – 3 days DR-G12-PA<br />

Parameterizing Safety Integrated – – 2 days DR-G12-SAF<br />

Courses SINAMICS G120X<br />

Parameterizing and commissioning – 1 day DR-G12X-PM<br />

Courses SINAMICS G130/G150/G180/S150<br />

DYNAVERT – commissioning and diagnostics – 2 days DR-DYNA<br />

SINAMICS G150/G130/S150 – diagnostics and service – 5 days DR-G15-DG<br />

SINAMICS G180 – diagnostics and service – – 2.5 days DR-G18-DG<br />

4<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/7


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Training<br />

SINAMICS G120X training case<br />

■ Overview<br />

■ Technical specifications<br />

Supply voltage<br />

Dimensions<br />

•Width<br />

•Height<br />

•Depth<br />

Weight, approx.<br />

SINAMICS G120X<br />

training case<br />

6AG1067-2AA00-0AC1<br />

230 V 1 AC<br />

290 mm (11.42 in)<br />

470 mm (18.50 in)<br />

300 mm (11.81 in)<br />

16.9 kg (37.26 lb)<br />

■ Selection and ordering data<br />

Description<br />

SINAMICS G120X training case<br />

Article No.<br />

6AG1067-2AA00-0AC1<br />

4<br />

SINAMICS G120X training case<br />

The SINAMICS G120X training case is a convincing demonstration<br />

system thanks to its compact design. It is suitable for direct<br />

customer presentations as well as for tests in technical<br />

departments. It enables the functions of SINAMICS G120X to be<br />

demonstrated and tested quickly and easily.<br />

It contains the following components:<br />

• SINAMICS G120X frequency converter, PROFINET,<br />

EtherNet/IP, 0.75 kW<br />

• Operator panels IOP-2<br />

• SINAMICS G120 Smart Access<br />

• SIMOTICS GP asynchronous (induction) motor<br />

The SINAMICS G120X training case is supplied as a trolley with<br />

a hood.<br />

4/8 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Control cabinets<br />

■ Overview<br />

Complete equipment for machine tools and<br />

production systems<br />

Our supplied range of products and services also includes<br />

<strong>complete</strong> equipment for machine tools and production systems<br />

with all services in the process chain from consulting through to<br />

after-sales service.<br />

We support you in the areas of engineering, production and<br />

logistics.<br />

Engineering support<br />

Siemens supports you with advice on design in accordance with<br />

standards and concepts for drive systems, <strong>control</strong>, operation<br />

and safety.<br />

Our engineers configure for you in EPLAN P8 and other commonly<br />

used CAD systems, execute projects designed to cost<br />

and adapt your documents where necessary to UL or new<br />

systems.<br />

Our Technical Competence Center Cabinets in Chemnitz<br />

supports you with selecting and optimizing the suitable <strong>control</strong><br />

cabinet air-conditioning system. Apart from calculation and<br />

simulation, we also use instrumentation testing in our heat<br />

laboratory with load simulation.<br />

We also offer the following services:<br />

• Vibration measurements and <strong>control</strong> cabinet certification in<br />

the field<br />

• Measurement of conducted interference voltages in our<br />

laboratory<br />

Cabinet engineering<br />

Testing in the heat laboratory<br />

Production at a high level of quality<br />

Complete equipment is manufactured at a high industrial level.<br />

This means:<br />

• Examining consistency of the order documentation<br />

• Checking for adherence to current regulations<br />

• Collision check in 3D layout, taking into account the free<br />

space required thermally and electrically<br />

• Automatic preparation of enclosures, cables and cable<br />

bundles<br />

• Automated inspection and shipment free of faults<br />

• Documentation and traceability<br />

• Declaration of conformity regarding the Low-Voltage Directive<br />

and manufacturer's declaration on machinery directive<br />

• UL label on request<br />

Superior logistics<br />

Everything from a single source offers you the following<br />

advantages:<br />

• Cost savings for procurement, stockkeeping, financing<br />

• Reduction in throughput times<br />

• Just-in-time delivery<br />

Individual support and maximum flexibility<br />

Our technical consultants for <strong>complete</strong> equipment support<br />

customers and sales departments in the various regions.<br />

Our <strong>control</strong> cabinet customers are supported in the Systems<br />

Engineering Plant Chemnitz (WKC) by ordering centers and<br />

production teams that are permanently assigned to customers.<br />

Distance does not present a problem; we also use web cams<br />

for consulting our customers.<br />

4<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/9


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Control cabinets<br />

■ Overview<br />

4<br />

Worldwide repair service<br />

Customer-specific logistics models, flexible production capacity<br />

and production areas as well as change management in all<br />

process phases ensure maximum flexibility.<br />

Customized supplementary products<br />

As part of its <strong>complete</strong> equipment program, Siemens also offers<br />

the development and construction of customized supplementary<br />

products, e.g. special operator panels and power supply<br />

systems.<br />

Liability for defects<br />

Of course we accept the same liability for defects for our<br />

<strong>complete</strong> equipment as for our SINUMERIK and SINAMICS<br />

products.<br />

Furthermore, you can use our worldwide repair service anywhere<br />

and at any time.<br />

Your benefits<br />

One partner, one quotation, one order, one delivery, one invoice,<br />

and one contact partner for liability of defects.<br />

For series production or individual items, Siemens is your<br />

competent partner for <strong>complete</strong> equipment.<br />

Control cabinet with SINAMICS S120 in booksize format<br />

4/10 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Applications<br />

■ Overview<br />

Our understanding of an application is the customer-specific<br />

solution of an automation task based on standard hardware and<br />

software components. In this respect, industry knowledge and<br />

technological expertise are just as important as expert knowledge<br />

about how our products and systems work. We are setting<br />

ourselves this challenge with more than 280 application<br />

engineers in 20 countries.<br />

Application centers<br />

We currently have application centers in:<br />

• Germany:<br />

Head Office in Erlangen and in other German regions, e.g.<br />

in Munich, Nuremberg, Stuttgart, Mannheim, Frankfurt,<br />

Chemnitz, Cologne, Bielefeld, Bremen, Hanover, Hamburg<br />

• Belgium: Brussels<br />

• Brazil: Sao Paulo<br />

• China: Beijing and 12 regions<br />

• Denmark: Ballerup<br />

• France: Paris<br />

• Great Britain: Manchester<br />

• India: Mumbai<br />

• Italy: Bologna, Milan<br />

• Japan: Tokyo, Osaka<br />

• The Netherlands: The Hague<br />

• Austria: Vienna<br />

• Poland: Warsaw<br />

• Sweden: Göteborg<br />

• Switzerland: Zurich, Lausanne<br />

• Spain: Madrid<br />

• South Korea: Seoul<br />

• Taiwan: Taipei<br />

• Turkey: Istanbul<br />

• USA: Atlanta<br />

These application centers specialize in the use of SIMATIC/<br />

SIMOTION/SINAMICS. You therefore can rely on automation<br />

and drive specialists for implementing successful applications.<br />

By involving your personnel at an early stage in the process,<br />

we can provide a solid basis for rapid knowledge transfer, maintenance<br />

and further development of your automation solution.<br />

Advice on applications and implementation<br />

We offer a variety of consultation services to help you find the<br />

optimum solution for the SIMATIC/SIMOTION/SINAMICS<br />

application you want to implement:<br />

The quotation phase includes<br />

• clarification of technical questions,<br />

• discussion of machine concepts and customer-specific<br />

solutions,<br />

• selection of suitable technology and<br />

• suggestions for implementation.<br />

A technical feasibility study is also performed at the outset.<br />

In this way, difficult points of the application can be identified<br />

and solved early on. We can also configure and implement your<br />

application as a <strong>complete</strong> solution from a single source.<br />

A large number of proven standard applications are available for<br />

use during the implementation phase. This saves engineering<br />

costs.<br />

The system can be commissioned by experienced, competent<br />

personnel, if required. This saves time and trouble.<br />

If servicing is required, we can support you on site or remotely.<br />

For further information about servicing, please see the section<br />

"Industry Services".<br />

On-site application training<br />

Training for the implemented applications can also be organized<br />

and carried out on site. This training for machine manufacturers<br />

and their customers does not deal with individual products,<br />

but the entire hardware and software system (for example,<br />

automation, <strong>drives</strong> and visualization).<br />

From an initial concept to successful installation and commissioning:<br />

We provide <strong>complete</strong> support for SIMATIC/<br />

SIMOTION/SINAMICS! Contact your Siemens representative.<br />

You can find further information at<br />

www.siemens.com/machinebuilding<br />

4<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/11


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Spare parts services<br />

Spare parts services during the lifecycle<br />

4<br />

You can sign up for the spare parts service that suits your<br />

■ Overview<br />

requirements perfectly:<br />

• Delivery of spare parts<br />

Operation and Maintenance<br />

Spare Part Delivery<br />

Exchange Delivery<br />

Repair<br />

Product Upgrade Service<br />

General Overhaul<br />

Functionality Check<br />

Extended spare parts availability<br />

Modernization • Delivery as exchange product<br />

• Repair<br />

• Product upgrade service<br />

• General overhaul<br />

• Function check<br />

• Return of diagnostic parts<br />

• Stock reduction of your spare parts store<br />

• Extended spare parts availability<br />

■ Benefits<br />

7 Optimum price/performance ratio and top quality<br />

Product upgrade service, general overhaul and extended spare<br />

parts availability additionally prolong your machine runtimes<br />

7 Lifecycle management over the <strong>complete</strong> lifecycle<br />

7 Outstanding quality and availability of your machines and<br />

plant using Siemens original spare parts<br />

Spare parts services during the lifecycle<br />

Siemens also provides constant support to customers after<br />

delivery of the machines or plant. This includes spare parts,<br />

repairs, as well as other supplementary services, and has a<br />

positive effect on machine operating times, inventories and<br />

costs.<br />

When customers purchase a high-quality machine or plant, they<br />

intend to use it as intensively as possible, preferably for three<br />

7 Global network and optimized logistics chains –<br />

24 hours a day, 365 days a year<br />

7 Additional services from Siemens<br />

■ More information<br />

More information is available on the Internet at:<br />

www.siemens.com/<strong>motion</strong><strong>control</strong>/spareparts<br />

shifts a day over many years. Under such circumstances, it is<br />

normal for parts to fail eventually. It is essential to replace the<br />

For further information, please approach your contact at your<br />

part as quickly as possible, because every hour of a plant stoppage<br />

local Siemens office.<br />

costs money. To satisfy the multi-faceted requirements Contact information is available on the Internet at:<br />

in the different areas, we have created comprehensive spare<br />

parts services.<br />

www.siemens.com/automation-contact<br />

Delivery of spare parts<br />

G_NC01_EN_00460a<br />

■ Overview<br />

■ Benefits<br />

In every industry worldwide, plants and systems are required to 7 New liability for defects for the spare part<br />

operate with constantly increasing reliability. Lack of a specific 7 Long-term spare parts availability<br />

spare part can result in considerable costs. We will provide you<br />

7 Optimum system compatibility<br />

with the support you need to prevent a standstill from occurring<br />

in the first place: with a worldwide network and optimum logistics<br />

chains.<br />

Ordering<br />

mode<br />

Logistics service<br />

Note<br />

Standard<br />

Cost-optimized:<br />

Contracted shipping<br />

company<br />

Delivery within the normal national<br />

delivery times through the contracted<br />

shipping company<br />

Plant<br />

stoppage<br />

Emergency<br />

service<br />

Time-optimized:<br />

Express, courier,<br />

collection<br />

Special logistics:<br />

Courier<br />

You choose the shortest possible<br />

delivery time for your own benefit:<br />

• Delivery by means of collection or<br />

courier service<br />

• Delivery by express service<br />

You can also order the spare parts<br />

from us outside normal working hours,<br />

as well as on weekends or national<br />

holidays round-the-clock.<br />

• Your delivery will arrive by courier<br />

4/12 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Return<br />

■ Overview<br />

In addition to the simple delivery of spare parts, with many<br />

products, we also offer you the option of an exchange. This has<br />

the advantage that you not only receive the spare part quickly,<br />

but are able to return the defective device to us for a credit. You<br />

therefore receive our spare part at the lower exchange price.<br />

A credit will be awarded on condition that the repair code indicates<br />

that repurchasing is admissible, a replacement is obtained<br />

from the spare parts store, and that the returned product is<br />

repairable.<br />

The ordering mode and logistics service determine the delivery<br />

of spare parts:<br />

■ Benefits<br />

Ordering Logistics service Note<br />

mode<br />

Standard<br />

Plant<br />

stoppage<br />

Cost-optimized:<br />

Contracted shipping<br />

company<br />

Time-optimized:<br />

Express, courier,<br />

collection<br />

Delivery within the normal national<br />

delivery times through the contracted<br />

shipping company<br />

You choose the shortest possible<br />

delivery time for your own benefit:<br />

• Delivery by means of collection or<br />

courier service<br />

• Delivery by express service<br />

Services and documentation<br />

Spare parts services<br />

Delivery as exchange product<br />

For returns, we require the following information:<br />

• Reason for return<br />

• If defective: detailed description of the fault<br />

• Machine number<br />

• Machine/system manufacturer<br />

• End customer<br />

We will then be able to provide you with additional information<br />

in the repair report/inspection report regarding the diagnosis/<br />

inspection as well as information about the <strong>complete</strong>d repair.<br />

7 Savings thanks to the option of returning defective parts<br />

7 A spare part is available immediately in the event of failure<br />

7 New liability for defects for the spare part<br />

7 Long-term spare parts availability<br />

7 Optimum system compatibility<br />

Emergency<br />

service<br />

Special logistics:<br />

Courier<br />

You can also order the spare parts<br />

from us outside normal working hours,<br />

as well as on weekends or national<br />

holidays round-the-clock.<br />

• Your delivery will arrive by courier<br />

■ Overview<br />

Downtimes cause problems in the plant as well as unnecessary<br />

costs. We can help you to reduce both to a minimum – with<br />

our worldwide repair facilities. The advantage for you: Defects<br />

can be rectified before they cause further harm.<br />

Repair is a favorable option when you have specific reasons<br />

for not replacing the defective device or part with a new one<br />

(delivery as exchange product).<br />

We maintain a global network of Siemens repair shops and<br />

certified partners to ensure that we will always be able to<br />

process your repairs quickly.<br />

We can offer you different types of repair depending on your<br />

requirements:<br />

Repair<br />

Function repair<br />

A function repair is the same as a normal repair but excludes the<br />

repair of cosmetic defects, e.g. scratches, labels, discoloration.<br />

The conditions applicable to function repairs should be observed<br />

in this case. The function repair service is only available<br />

for machine manufacturers or machine operators. Please ask<br />

your regional Siemens contact.<br />

For repairs, we require the following information:<br />

• Reason for return<br />

• If defective: detailed fault report<br />

• Machine number<br />

• Machine/system manufacturer<br />

• End customer<br />

4<br />

Normal repair<br />

■ Benefits<br />

Normal repair at standard conditions normally takes 10 working<br />

days following receipt of the defective item at our repair shop.<br />

Fast repair<br />

In particularly urgent cases, we offer you the option of a fast<br />

repair within 1 or 2 working days for many products at additional<br />

cost.<br />

Turnaround repair<br />

With a turnaround repair, we organize on your behalf collection<br />

of the device/component to be repaired.<br />

Mobile repair service<br />

We come to you and perform the required repairs on site, for<br />

example, when the device/component cannot be removed due<br />

to its weight.<br />

7 Short downtimes for machines and plants<br />

7 Only certified original parts are used<br />

7 Additional services from Siemens:<br />

• Longer availability of your machine/plant through the<br />

preventive replacement of wear parts and aging parts<br />

• Highest standards of quality<br />

• Use of the comprehensive test concept of series production,<br />

including software, firmware, ASICs, complex function<br />

blocks, etc.<br />

• Implementation of all the hardware and software/firmware<br />

enhancements known by development, production, service<br />

and quality management departments, as well as suppliers<br />

7 Information supplied by repair report/inspection report<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/13


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Spare parts services<br />

Product upgrade service<br />

■ Overview<br />

A planned product upgrade from OLD to NEW helps to prevent<br />

unplanned machine stoppages and supports a safer and longer<br />

machine/plant availability. The upgrade service is mainly offered<br />

for older components that will soon be discontinued.<br />

For information about potential upgrades from the latest upgrade<br />

list, please ask your regional Siemens contact. The product upgrade<br />

service is only available for machine manufacturers or<br />

machine operators.<br />

Product upgrade service: From OLD to NEW<br />

A long service life is expected from machines and plants. The<br />

service life of the electronic components is, however, limited and<br />

normally shorter than the planned machine/plant operating<br />

times. To ensure that the required extended availability of the<br />

machine/plant is achieved, we offer you the product upgrade<br />

service at an attractive price.<br />

In the course of their lifecycle, electronic components are<br />

normally redesigned/upgraded several times. With the product<br />

upgrade service, you will always receive the latest technology.<br />

■ Benefits<br />

7 Price benefit through upgrade service<br />

7 New liability for defects for the new component<br />

7 Extended availability of your machine/plant<br />

7 Prevention of component failures due to wear and aging<br />

7 Prevention of machine stoppages due to unavailability of<br />

spare parts<br />

7 Reduced spare parts inventories<br />

7 Latest technology<br />

7 Easier servicing due to fewer variants<br />

7 Industry Services through Siemens are assured for the future<br />

General overhaul<br />

4<br />

■ Overview<br />

Extension of the constant failure rate period<br />

During the planned general overhaul, wear parts and aging<br />

parts are replaced in accordance with their stated service life so<br />

as to reduce unplanned downtimes. In the case of motors, in<br />

addition to a general overhaul, replacement of bearings and<br />

encoders is also offered.<br />

Failure rate<br />

Early<br />

failures<br />

Operating time of the plant<br />

Extension of constant<br />

failure rate period<br />

Ware out<br />

failures<br />

Warranty General overhaul<br />

Constant failure rate period<br />

Constant failure rate period with general overhaul<br />

Extension of the period with a constant failure rate<br />

A long service life is expected from machines and plants. The<br />

service life of electronic components and mechanical parts is,<br />

however, limited and normally shorter than the planned machine/<br />

plant operating times. For higher availability of the machines or<br />

plants, we offer a general overhaul (preventive maintenance) for<br />

electronic components and motors at favorable conditions.<br />

G_NC01_EN_00459a<br />

If a fault is detected during a general overhaul, troubleshooting<br />

and repair will be performed at the repair price without requesting<br />

confirmation or interrupting the process. In the case of extensive<br />

wear or damage, a general overhaul/repair will not be performed.<br />

A fixed lump sum for expenses will be charged in this<br />

case.<br />

■ Benefits<br />

7 Preventive replacement of wear parts and aging parts in<br />

accordance with their stated service life<br />

7 Reduction in unplanned plant stoppages<br />

7 Enhanced production reliability<br />

7 Extended availability of your machine/plant<br />

7 New liability for defects for 12 months for the components<br />

subjected to a general overhaul<br />

7 Low price<br />

4/14 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Spare parts services<br />

Function check<br />

■ Overview<br />

■ Benefits<br />

It is checked that the components function reliably.<br />

7 The component is checked and can be deployed again<br />

7<br />

The first step involves cleaning the component. Then all the<br />

The component contains all the known improvements<br />

hardware and software/firmware enhancements are implemented<br />

that are known by development, production, service and 7 Low price<br />

7 The customer's own spare parts stock is up-to-date<br />

quality management departments, as well as suppliers. Using<br />

the comprehensive test concept of series production, all the<br />

functions of the software, firmware, ASICs, complex and less<br />

complex function blocks are checked.<br />

If a fault is detected during the function check, troubleshooting<br />

and repair will be performed at the repair price without requesting<br />

confirmation or interrupting the process. In the case of extensive<br />

wear or damage, no repairs will be performed. A fixed lump<br />

sum for expenses will be charged.<br />

Return of diagnostic parts<br />

■ Overview<br />

■ Benefits<br />

7 Can be used for diagnostics<br />

7 Reduced spare parts inventories<br />

7 Low costs<br />

4<br />

Spare parts used for diagnostic purposes from the spare parts<br />

store can be returned within 3 months and a credit note for up to<br />

85 % is issued.<br />

For unused spare parts in their original packaging, you will receive<br />

a credit of 100 % in which case you will be charged a fixed<br />

price for handling.<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/15


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Spare parts services<br />

Stock reduction in spare parts store<br />

■ Overview<br />

■ Benefits<br />

7 Reduced costs<br />

7 Stock optimization<br />

7 Minimization of fault downtimes<br />

Thanks to fast delivery of spare parts from Siemens, manufacturers<br />

and plant operators are able to reduce their spare parts<br />

inventories. Siemens offers an analysis for this purpose to indicate<br />

exactly which parts must be available in the customer's<br />

stores for a specific combination of machines and which should<br />

be obtained directly from Siemens.<br />

4<br />

Extended spare part availability<br />

■ Overview<br />

■ Benefits<br />

We normally retain spare parts for all products and systems for 7 Higher plant availability<br />

a period of 10 years after discontinuation of product marketing. 7 Investment protection<br />

In individual cases, when we do not carry spare parts, we will 7 Reduction of lifecycle costs<br />

offer a repair.<br />

For a wide range of products and systems, we extend the availability<br />

of spare parts. We can provide you with the current spare<br />

parts availability for your machine/plant as a service once you<br />

have registered online with identSNAPSHOT.<br />

www.siemens.com/identsnapshot<br />

If you require longer availability of spare parts, please contact<br />

your regional sales representative.<br />

4/16 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Spares on Web<br />

■ Overview<br />

Spares on Web – online identification of spare parts<br />

Spares on Web is a web-based tool for identifying spare parts.<br />

After you have entered the Article No. and serial number, the<br />

spare parts available for the relevant unit are displayed.<br />

www.siemens.com/sow<br />

4<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/17


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Product Partner – Drives Options<br />

■ Overview<br />

Siemens Product Partners for Drives Options<br />

Individual options for our <strong>drives</strong><br />

In order to meet as many customer requirements as possible<br />

in the field of drive technology, in addition to its own products,<br />

Siemens also relies on the individual and complementary<br />

services of selected partners.<br />

We are increasingly focusing on the standard drive options, and<br />

our Siemens Product Partners for Drives Options supplement<br />

our <strong>drives</strong> with individual drive options.<br />

This gives Siemens a unique flexibility to meet all application<br />

requirements. Naturally, we support our Siemens Product<br />

Partners for Drives Options in tailoring their options perfectly<br />

to our <strong>drives</strong>.<br />

For you as our customer, there are multiple benefits:<br />

• The Siemens Product Partners for Drives Options meet the<br />

same high standards of quality and performance that we<br />

place on our own products<br />

• Drive options can be adapted to individual requirements/<br />

designs<br />

• The Siemens Product Partners for Drives Options know our<br />

Siemens converter portfolio and can advise you individually<br />

and quickly<br />

Converter<br />

Motor<br />

Line filters<br />

1)<br />

Line reactors/<br />

line reactors as base<br />

components1)<br />

Sine-wave filters<br />

dv/dt filters<br />

Output reactors<br />

1)<br />

4<br />

G_D011_EN_00529a<br />

Braking resistors/<br />

braking resistors as base components<br />

1)<br />

1)<br />

Options that can be supplied from Siemens as well as from Product Partners for Drives Options.<br />

Schematic circuit diagram<br />

■ More information<br />

You can find more information on the Internet at<br />

www.siemens.com/<strong>drives</strong>-options-partner<br />

4/18 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

mySupport documentation<br />

■ Overview<br />

mySupport documentation –<br />

Compiling personal documents<br />

■ Benefits<br />

•Display<br />

View, print or download standard documents or personalized<br />

documents<br />

•Configure<br />

Transfer standard documents or parts of them to personalized<br />

documents<br />

• Generate/Manage<br />

Generate and manage personalized documents in the formats<br />

PDF, RTF or XML in all available languages<br />

mySupport documentation is a web-based system for generating<br />

personalized documentation based on standard documents<br />

and is part of the Siemens Industry Online Support portal.<br />

In mySupport, a personal document library can be created in the<br />

"Documentation" category. This library can be accessed online<br />

in mySupport or also be generated in various formats for offline<br />

use.<br />

Previously, this functionality was available in the My Documentation<br />

Manager for configurable manuals. Due to the integration in<br />

mySupport, all entries of the Industry Online Support can now<br />

be imported into the personal document library, including FAQs<br />

or product notifications.<br />

If you have already worked with the My Documentation Manager,<br />

all of the previously created libraries will continue to be available<br />

without restrictions in mySupport.<br />

In addition, the personal library in mySupport can be shared with<br />

other mySupport users. In this way, a collection of relevant<br />

documents can be created very effectively and used together<br />

with other mySupport users all over the world.<br />

You must register/log in for configuring and generating/<br />

managing.<br />

■ Function<br />

Opening mySupport documentation in the Industry Online<br />

Support portal<br />

• About the product support, entry type "Manual":<br />

https://support.industry.siemens.com/cs/ww/en/ps/man<br />

By clicking on the required version of the manual and then<br />

"Show and configure", the manual opens in a modular view,<br />

where you can navigate from topic to topic. Here the direct link<br />

to a topic can be used and made available to other users. The<br />

selected document can be added to the personal library via<br />

"mySupport Cockpit" > "Add to mySupport documentation".<br />

• Via the direct link<br />

https://support.industry.siemens.com/my/ww/en/<br />

documentation/advanced<br />

After logon/registration, the online help is displayed as the<br />

current document.<br />

■ More information<br />

You can find additional information on the Internet at<br />

• https://support.industry.siemens.com/my/ww/en/<br />

documentation<br />

• https://support.industry.siemens.com/cs/helpcenter/en/<br />

index.htm?#persoenliche_bibliothek_aufbauen.htm<br />

4<br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/19


© Siemens <strong>2020</strong><br />

4<br />

Services and documentation<br />

Documentation<br />

General documentation<br />

■ Overview<br />

A high-quality programmable <strong>control</strong> or drive system can be<br />

used to maximum effect only if the user is aware of the performance<br />

of the products used as a result of intensive training<br />

and good technical documentation.<br />

This is becoming more important due to the shorter innovation<br />

cycles of modern automation products and the convergence<br />

of electronics and mechanical engineering.<br />

A comprehensive range of documentation is available which<br />

includes a Getting Started guide, operating instructions,<br />

installation manuals and a list manual.<br />

The documents are available in hardcopy form or as a PDF file<br />

for downloading from the Internet.<br />

Information and documentation relating to SINUMERIK,<br />

SINAMICS, SIMOTION and SIMOTICS are available on the<br />

Internet at<br />

https://support.industry.siemens.com/cs/document/109476679<br />

■ Application<br />

Explanations of the manuals:<br />

• Operating Instructions<br />

contain all the information needed to install the device and<br />

make electrical connections, information about commissioning<br />

and a description of the converter functions.<br />

Phases of use: Control cabinet construction, commissioning,<br />

operation, maintenance and servicing.<br />

• Hardware Installation Manual<br />

contains all relevant information about the intended use of the<br />

components of a system (technical specifications, interfaces,<br />

dimensional drawings, characteristics, or possible applications),<br />

information about installation and electrical connections<br />

and information about maintenance and servicing.<br />

Phases of use: Control cabinet configuration/construction,<br />

maintenance and servicing.<br />

• Operating and Installation Instructions<br />

(for converter and accessories)<br />

contain all relevant information about the intended use of the<br />

components, such as technical specifications, interfaces,<br />

dimensional drawings, characteristics, or possible<br />

applications.<br />

Phases of use: Control cabinet configuration/construction.<br />

• Manual/Configuration Manual<br />

contains all necessary information about the intended use<br />

of the components of a system, e.g. technical specifications,<br />

interfaces, dimensional drawings, characteristics, or possible<br />

applications.<br />

Phases of use: Cabinet configuration/setup, circuit diagram<br />

configuration/drawing.<br />

• Commissioning Manual<br />

contains all information relevant to commissioning after<br />

installation and wiring. It also contains all safety and warning<br />

notices relevant to commissioning in addition to overview<br />

drawings.<br />

Phases of use: Commissioning of components that have<br />

already been connected, configuration of system functions.<br />

• List Manual<br />

contains all parameters, function diagrams, and faults/alarms<br />

for the product/system as well as their meanings and setting<br />

options. It contains parameter data and fault/alarm descriptions<br />

with functional correlations.<br />

Phases of use: Commissioning of components that have<br />

already been connected, configuration of system functions,<br />

fault cause/diagnosis.<br />

• Getting Started<br />

provides information about getting started for the first-time<br />

user as well as references to additional information. It contains<br />

information about the basic steps to be taken during commissioning.<br />

The information in the other documentation should<br />

be carefully observed for all of the other work required.<br />

Phases of use: Commissioning of components that have<br />

already been connected.<br />

• Function Manual Drive Functions<br />

contains all the relevant information about individual drive<br />

functions: Description, commissioning and integration in the<br />

drive system.<br />

Phases of use: Commissioning of components that have<br />

already been connected, configuration of system functions.<br />

4/20 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Documentation<br />

General documentation<br />

■ Selection and ordering data<br />

Description<br />

Article No.<br />

Automating with PROFINET:<br />

Via bookstore<br />

Industrial Communication Based on<br />

Industrial Ethernet<br />

•German ISBN 978-3-89578-293-0<br />

• <strong>English</strong> ISBN 978-3-89578-294-7<br />

SINAMICS G120X documentation<br />

■ Overview<br />

Compact Installation Instructions are supplied in hard copy<br />

form in German and <strong>English</strong> with every SINAMICS G120X.<br />

Further documentation, such as the operating instructions, is<br />

available free on the Internet at:<br />

www.siemens.com/sinamics-g120x/documentation<br />

Detailed information on the SINAMICS G120X infrastructure converters<br />

for HVAC/Water/Wastewater, including the latest technical<br />

documentation (brochures, tutorials, dimensional drawings,<br />

certificates and operating instructions), is available on the<br />

Internet at:<br />

www.siemens.com/sinamics-g120x<br />

and is also available via the Drive Technology Configurator<br />

(DT Configurator) on the Internet.<br />

The DT Configurator can be found in the Siemens Industry Mall<br />

at the following address:<br />

www.siemens.com/dt-configurator<br />

4<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong><br />

Siemens D 31.5 · March <strong>2020</strong><br />

4/21


© Siemens <strong>2020</strong><br />

Services and documentation<br />

Documentation<br />

Notes<br />

4<br />

4/22 Siemens D 31.5 · March <strong>2020</strong>


Appendix<br />

© Siemens <strong>2020</strong><br />

5<br />

5/2 Certificates of suitability (approvals)<br />

5/4 Software licenses<br />

5/6 Conversion tables<br />

5/8 Metal surcharges<br />

5/11 Conditions of sale and delivery<br />

Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Appendix<br />

Certificates of suitability (approvals)<br />

■ Overview<br />

Many of the products in this catalog fulfill requirements, e.g. for<br />

UL, CSA or FM and are labeled with the corresponding approval<br />

designation.<br />

All of the certificates of suitability, approvals, certificates,<br />

declarations of conformity, test certificates, e.g. CE, UL, Safety<br />

Integrated etc. have been performed with the associated system<br />

components as they are described in the Catalogs and<br />

Configuration Manuals.<br />

The certificates are only valid if the products are used with the<br />

described system components, are installed according to the<br />

Installation Guidelines and used for their intended purpose.<br />

In other cases, the vendor of these products is responsible for<br />

arranging for the issue of new certificates.<br />

5<br />

Test code Tested by Device series/<br />

Component<br />

UL: Underwriters Laboratories<br />

Independent public testing body in North America<br />

UL according to UL standard<br />

UL according to CSA standard<br />

UL according to UL and CSA standards<br />

Test standard<br />

Product category/<br />

File No.<br />

SINUMERIK Standard UL 5<strong>08</strong>, CSA C22.2 No. 142 NRAQ/7.E164110<br />

NRAQ/7.E217227<br />

SIMOTION Standard UL 5<strong>08</strong>, CSA C22.2 No. 142 NRAQ/7.E164110<br />

SINAMICS Standard UL 5<strong>08</strong>, 5<strong>08</strong>C, 61800-5-1<br />

CSA C22.2 No. 142, 274<br />

NRAQ/7.E164110,<br />

NMMS/2/7/8.E192450,<br />

NMMS/2/7/8.E2<strong>03</strong>250,<br />

NMMS/7.E214113,<br />

NMMS/7.E253831<br />

NMMS/2/7/8.E121068<br />

NMMS/7.E355661<br />

NMMS/7.E323473<br />

UL according to UL standard<br />

SIMODRIVE Standard UL 5<strong>08</strong>C, CSA C22.2 No. 274 NMMS/2/7/8.E192450<br />

NMMS/7.E214113<br />

UL according to CSA standard<br />

SIMOTICS Standard UL 1004-1, 1004-6, 1004-8,<br />

CSA C22.2 No. 100<br />

PRGY2/8.E227215<br />

PRHZ2/8.E93429<br />

UL according to UL and CSA standards<br />

PRHJ2/8.E342747<br />

PRGY2/8.E253922<br />

PRHZ2/8.E342746<br />

Line/motor reactors Standard UL 5<strong>08</strong>, 506, 5<strong>08</strong>5-1, 5<strong>08</strong>5-2, 1561, XQNX2/8.E257859<br />

CSA C22.2 No. 14, 47, 66.1-06, 66.2-06<br />

NMTR2/8.E219022<br />

NMMS2/8.E333628<br />

XPTQ2/8.E257852<br />

XPTQ2/8.E1<strong>03</strong>521<br />

NMMS2/8.E224872<br />

XPTQ2/8.E354316<br />

XPTQ2/8.E198309<br />

XQNX2/8.E475972<br />

Line filters, dv/dt filters, UL 1283, CSA C22.2 No. 8<br />

FOKY2/8.E70122<br />

sine-wave filters<br />

Resistors UL 5<strong>08</strong>, 5<strong>08</strong>C, CSA C22.2 No. 14, 274 NMTR2/8.E224314<br />

NMMS2/8.E192450<br />

NMTR2/8.E221095<br />

NMTR2/8.E226619<br />

TUV: TUV Rheinland of North America Inc.<br />

Independent public testing body in North America, Nationally Recognized Testing Laboratory (NRTL)<br />

TÜV: TÜV SÜD Product Service<br />

Independent public testing body in Germany, Nationally Recognized Testing Laboratory (NRTL) for North America<br />

TUV according to UL and CSA standards SINAMICS NRTL listing according to standard UL 5<strong>08</strong>C U7V 12 06 20078 013<br />

U7 11 04 20078 009<br />

U7 11 04 20078 010<br />

U7 11 04 20078 011<br />

SIMOTION NRTL listing according to standard UL 5<strong>08</strong> U7V 13 <strong>03</strong> 20078 01<br />

SIMODRIVE NRTL listing according to standard UL 5<strong>08</strong>C, CU 72090702<br />

CSA C22.2. No. 14<br />

Motion Control Encoder NRTL listing according to UL 61010-1 U8V 10 06 20196 024<br />

CSA C22.2 No. 61010-1<br />

5/2 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Appendix<br />

Certificates of suitability (approvals)<br />

■ Overview<br />

Test code Tested by Device series/<br />

Component<br />

CSA: Canadian Standards Association<br />

Independent public testing body in Canada<br />

Test standard<br />

Product category/<br />

File No.<br />

CSA according to CSA standard SINUMERIK Standard CSA C22.2 No. 142 2252-01 : LR 102527<br />

FMRC: Factory Mutual Research Corporation<br />

Independent public testing body in North America<br />

FM according to FM standard SINUMERIK Standard FMRC 3600, FMRC 3611,<br />

FMRC 3810, ANSI/ISA S82.02.1<br />

–<br />

EAC: Ivanovo-Certificate<br />

Independent public testing body in the Russian Federation<br />

EAC in accordance with the EAC Directive SINAMICS<br />

SINUMERIK<br />

SIMOTION<br />

RCM: Australian Communications and Media Authority<br />

Independent public testing body in Australia<br />

RCM according to EMC standard<br />

KC: National Radio Research Agency<br />

Independent public testing body in South Korea<br />

KC according to EMC standard<br />

SINAMICS<br />

SINUMERIK<br />

SIMOTION<br />

SINAMICS<br />

SINUMERIK<br />

SIMOTION<br />

BIA<br />

Federal Institute for Occupational Safety<br />

– Functional safety SINAMICS<br />

SINUMERIK<br />

SIMOTION<br />

TÜV SÜD Rail<br />

– Functional safety SINAMICS<br />

SINUMERIK<br />

SIMOTION<br />

Standard IEC 61800-5-1/-2, IEC 61800-3 –<br />

Standard IEC AS 61800-3, EN 61800-3 –<br />

Standard KN 11 –<br />

Standard EN 61800-5-2 –<br />

Standard EN 61800-5-2 –<br />

More information about certificates can be found online at:<br />

https://support.industry.siemens.com/cs/ww/en/ps/cert<br />

5<br />

Siemens D 31.5 · March <strong>2020</strong><br />

5/3


© Siemens <strong>2020</strong><br />

Appendix<br />

5<br />

Software licenses<br />

■ Overview<br />

Software types<br />

Software requiring a license is categorized into types.<br />

The following software types have been defined:<br />

• Engineering software<br />

• Runtime software<br />

Engineering software<br />

This includes all software products for creating (engineering)<br />

user software, e.g. for configuring, programming, parameterizing,<br />

testing, commissioning or servicing.<br />

Data generated with engineering software and executable<br />

programs can be duplicated for your own use or for use by thirdparties<br />

free-of-charge.<br />

Runtime software<br />

This includes all software products required for plant/machine<br />

operation, e.g. operating system, basic system, system expansions,<br />

drivers, etc.<br />

The duplication of the runtime software and executable programs<br />

created with the runtime software for your own use or for<br />

use by third-parties is subject to a charge.<br />

You can find information about license fees according to use in<br />

the ordering data (e.g. in the catalog). Examples of categories of<br />

use include per CPU, per installation, per channel, per instance,<br />

per axis, per <strong>control</strong> loop, per variable, etc.<br />

Information about extended rights of use for parameterization/configuration<br />

tools supplied as integral components of the<br />

scope of supply can be found in the readme file supplied with<br />

the relevant product(s).<br />

License types<br />

Siemens Industry Automation & Drive Technologies offers various<br />

types of software license:<br />

• Floating license<br />

• Single license<br />

• Rental license<br />

• Rental floating license<br />

• Trial license<br />

• Demo license<br />

• Demo floating license<br />

Floating license<br />

The software may be installed for internal use on any number of<br />

devices by the licensee. Only the concurrent user is licensed.<br />

The concurrent user is the person using the program. Use<br />

begins when the software is started.<br />

A license is required for each concurrent user.<br />

Single license<br />

Unlike the floating license, a single license permits only one<br />

installation of the software per license.<br />

The type of use licensed is specified in the ordering data and<br />

in the Certificate of License (CoL). Types of use include for<br />

example per instance, per axis, per channel, etc.<br />

One single license is required for each type of use defined.<br />

Rental license<br />

A rental license supports the "sporadic use" of engineering<br />

software. Once the license key has been installed, the software<br />

can be used for a specific period of time (the operating hours do<br />

not have to be consecutive).<br />

One license is required for each installation of the software.<br />

Rental floating license<br />

The rental floating license corresponds to the rental license,<br />

except that a license is not required for each installation of the<br />

software. Rather, one license is required per object (for example,<br />

user or device).<br />

Trial license<br />

A trial license supports "short-term use" of the software in a nonproductive<br />

context, e.g. for testing and evaluation purposes.<br />

It can be transferred to another license.<br />

Demo license<br />

The demo license support the "sporadic use" of engineering software<br />

in a non-productive context, for example, use for testing<br />

and evaluation purposes. It can be transferred to another<br />

license. After the installation of the license key, the software can<br />

be operated for a specific period of time, whereby usage can be<br />

interrupted as often as required.<br />

One license is required per installation of the software.<br />

Demo floating license<br />

The demo floating license corresponds to the demo license,<br />

except that a license is not required for each installation of the<br />

software. Rather, one license is required per object (for example,<br />

user or device).<br />

Certificate of License (CoL)<br />

The CoL is the licensee's proof that the use of the software has<br />

been licensed by Siemens. A CoL is required for every type of<br />

use and must be kept in a safe place.<br />

Downgrading<br />

The licensee is permitted to use the software or an earlier version/release<br />

of the software, provided that the licensee owns<br />

such a version/release and its use is technically feasible.<br />

Delivery versions<br />

Software is constantly being updated.<br />

The following delivery versions<br />

• PowerPack<br />

• Upgrade<br />

can be used to access updates.<br />

Existing bug fixes are supplied with the ServicePack version.<br />

PowerPack<br />

PowerPacks can be used to upgrade to more powerful software.<br />

The licensee receives a new license agreement and CoL<br />

(Certificate of License) with the PowerPack. This CoL, together<br />

with the CoL for the original product, proves that the new software<br />

is licensed.<br />

A separate PowerPack must be purchased for each original<br />

license of the software to be replaced.<br />

Upgrade<br />

An upgrade permits the use of a new version of the software on<br />

the condition that a license for a previous version of the product<br />

is already held.<br />

The licensee receives a new license agreement and CoL with<br />

the upgrade. This CoL, together with the CoL for the previous<br />

product, proves that the new version is licensed.<br />

A separate upgrade must be purchased for each original license<br />

of the software to be upgraded.<br />

5/4 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Appendix<br />

Software licenses<br />

■ Overview<br />

ServicePack<br />

ServicePacks are used to debug existing products.<br />

ServicePacks may be duplicated for use as prescribed according<br />

to the number of existing original licenses.<br />

License key<br />

Siemens Industry Automation & Drive Technologies supplies<br />

software products with and without license keys.<br />

The license key serves as an electronic license stamp and<br />

is also the "switch" for activating the software (floating license,<br />

rental license, etc.).<br />

The <strong>complete</strong> installation of software products requiring license<br />

keys includes the program to be licensed (the software) and the<br />

license key (which represents the license).<br />

Software <strong>Update</strong> Service (SUS)<br />

As part of the SUS contract, all software updates for the respective<br />

product are made available to you free of charge for a period<br />

of one year from the invoice date. The contract will automatically<br />

be extended for one year if it is not canceled three months<br />

before it expires.<br />

The possession of the current version of the respective software<br />

is a basic condition for entering into an SUS contract.<br />

You can download explanations concerning license conditions from<br />

https://mall.industry.siemens.com/legal/ww/en/terms_of_trade_en.pdf<br />

5<br />

Siemens D 31.5 · March <strong>2020</strong><br />

5/5


© Siemens <strong>2020</strong><br />

Appendix<br />

2 2 2 2 2 2<br />

Conversion tables<br />

■ Rotary inertia (to convert from A to B, multiply by entry in table)<br />

B lb-in 2 lb-ft 2 lb-in-s 2 lb-ft-s 2<br />

A<br />

slug-ft 2 kg-cm kg-cm-s gm-cm gm-cm-s oz-in oz-in-s<br />

lb-in 2 1 6.94 × 10 –3 2.59 × 10 –3 2.15 × 10 –4 2.926 2.98 × 10 –3 2.92 × 10 3 2.984 16 4.14 × 10 –2<br />

lb-ft 2 144 1 0.3729 3.10 × 10 –2 421.40 0.4297 4.21 × 10 5 429.71 2304 5.967<br />

lb-in-s 2 386.<strong>08</strong> 2.681 1 8.33 × 10 –2 1.129 × 10 3 1.152 1.129 × 10 6 1.152 × 10 3 6.177 × 10 3 16<br />

lb-ft-s 2 4.63 × 10 32.17 12 1 1.35 × 10 4 13.825 1.355 × 10 7 1.38 × 10 4 7.41 × 10 4 192<br />

slug-ft 2<br />

kg-cm 2 0.3417 2.37 × 10 –3 8.85 × 10 –4 7.37 × 10 –5 1 1.019 × 10 –3 1000 1.019 5.46 1.41 × 10 –2<br />

kg-cm-s 2 335.1 2.327 0.8679 7.23 × 10 –2 980.66 1 9.8 × 10 5 1000 5.36 × 10 3 13.887<br />

gm-cm 2 3.417 × 10 –4 2.37 × 10 –6 8.85 × 10 –7 7.37 × 10 –8 1 × 10 –3 1.01 × 10 –6 1 1.01 × 10 –3 5.46 × 10 –3 1.41 × 10 –5<br />

gm-cm-s 2 0.335 2.32 × 10 –3 8.67 × 10 –4 7.23 × 10 –5 0.9806 1 × 10 –3 980.6 1 5.36 1.38 × 10 –2<br />

oz-in 2 0.0625 4.34 × 10 –4 1.61 × 10 –4 1.34 × 10 –5 0.182 1.86 × 10 –4 182.9 0.186 1 2.59 × 10 –3<br />

oz-in-s 2 24.13 0.1675 6.25 × 10 –2 5.20 × 10 –3 70.615 7.20 × 10 –2 7.09 × 10 4 72.0 386.<strong>08</strong> 1<br />

■ Torque (to convert from A to B, multiply by entry in table)<br />

B lb-in lb-ft oz-in N-m kg-cm kg-m gm-cm dyne-cm<br />

A<br />

lb-in 1 8.333 × 10 –2 16 0.113 1.152 1.152 × 10 –2 1.152 × 10 3 1.129 × 10 6<br />

lb-ft 12 1 192 1.355 13.825 0.138 1.382 × 10 4 1.355 × 10 7<br />

oz-in 6.25 × 10 –2 5.2<strong>08</strong> × 10 –3 1 7.061 × 10 –3 7.200 × 10 –2 7.200 × 10 –4 72.007 7.061 × 10 4<br />

N-m 8.850 0.737 141.612 1 10.197 0.102 1.019 × 10 4 1 × 10 7<br />

kg-cm 0.8679 7.233 × 10 –2 13.877 9.806 × 10 –2 1 10 –2 1000 9.806 × 10 5<br />

kg-m 86.796 7.233 1.388 × 10 3 9.806 100 1 1 × 10 5 9.806 × 10 7<br />

gm-cm 8.679 × 10 –4 7.233 × 10 –5 1.388 × 10 –2 9.806 × 10 –5 1 × 10 –3 1 × 10 –5 1 980.665<br />

dyne-cm 8.850 × 10 –7 7.375 × 10 –8 1.416 × 10 –5 10 –7 1.0197 × 10 –6 1.019 × 10 –8 1.019 × 10 –3 1<br />

5<br />

■ Length (to convert from A to B, multiply by entry in table)<br />

B inches feet cm yd mm m<br />

A<br />

inches 1 0.<strong>08</strong>33 2.54 0.028 25.4 0.0254<br />

feet 12 1 30.48 0.333 304.8 0.3048<br />

cm 0.3937 0.<strong>03</strong>281 1 1.09 × 10 –2 10 0.01<br />

yd 36 3 91.44 1 914.4 0.914<br />

mm 0.<strong>03</strong>937 0.0<strong>03</strong>28 0.1 1.09 × 10 –3 1 0.001<br />

m 39.37 3.281 100 1.09 1000 1<br />

■ Power (to convert from A to B, multiply by entry in table)<br />

B hp<br />

Watts<br />

A<br />

hp (<strong>English</strong>) 1 745.7<br />

(lb-in) (deg./s) 2.645 × 10 –6 1.972 × 10 –3<br />

(lb-in) (rpm) 1.587 × 10 –5 1.183 × 10 –2<br />

(lb-ft) (deg./s) 3.173 × 10 –5 2.366 × 10 –2<br />

(lb-ft) (rpm) 1.904 × 10 –4 0.1420<br />

Watts 1.341 × 10 –3 1<br />

■ Force (to convert from A to B, multiply by entry in table)<br />

B lb oz gm dyne N<br />

A<br />

lb 1 16 453.6 4.448 × 10 5 4.4482<br />

oz 0.0625 1 28.35 2.780 × 10 4 0.27801<br />

gm 2.205 × 10 –3 0.<strong>03</strong>527 1 1.02 × 10 –3 N.A.<br />

dyne 2.248 × 10 –6 3.59 × 10 –5 980.7 1 0.00001<br />

N 0.22481 3.5967 N.A. 100000 1<br />

■ Mass (to convert from A to B, multiply by entry in table)<br />

B lb oz gm kg slug<br />

A<br />

lb 1 16 453.6 0.4536 0.<strong>03</strong>11<br />

oz 6.25 × 10 –2 1 28.35 0.02835 1.93 × 10 –3<br />

gm 2.205 × 10 –3 3.527 × 10 –2 1 10 –3 6.852 × 10 –5<br />

kg 2.205 35.27 10 3 1 6.852 × 10 –2<br />

slug 32.17 514.8 1.459 × 10 4 14.59 1<br />

■ Rotation (to convert from A to B, multiply by entry in table)<br />

B rpm rad/s degrees/s<br />

A<br />

rpm 1 0.105 6.0<br />

rad/s 9.55 1 57.30<br />

degrees/s 0.167 1.745 × 10 –2 1<br />

5/6 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Appendix<br />

■ Temperature Conversion<br />

°F °C °C °F<br />

0 –17.8 –10 14<br />

32 0 0 32<br />

50 10 10 50<br />

70 21.1 20 68<br />

90 32.2 30 86<br />

98.4 37 37 98.4<br />

212 100 100 212<br />

subtract 32 and multiply by 5 / 9 multiply by 9 / 5 and add 32<br />

■ Mechanism Efficiencies<br />

Acme-screw with brass nut ~0.35–0.65<br />

Acme-screw with plastic nut ~0.50–0.85<br />

Ball-screw ~0.85–0.95<br />

Chain and sprocket ~0.95–0.98<br />

Preloaded ball-screw ~0.75–0.85<br />

Spur or bevel-gears ~0.90<br />

Timing belts ~0.96–0.98<br />

Worm gears ~0.45–0.85<br />

Helical gear (1 reduction) ~0.92<br />

■ Friction Coefficients<br />

Materials<br />

<br />

Steel on steel (greased) ~0.15<br />

Plastic on steel ~0.15–0.25<br />

Copper on steel ~0.30<br />

Brass on steel ~0.35<br />

Aluminum on steel ~0.45<br />

Steel on steel ~0.58<br />

Mechanism<br />

<br />

Ball bushings


© Siemens <strong>2020</strong><br />

Appendix<br />

5<br />

Metal surcharges<br />

1) 2) 3) 4)<br />

■ Explanation of the raw material/metal surcharges<br />

Surcharge calculation<br />

To compensate for variations in the price of the raw materials<br />

silver, copper, aluminum, lead, gold, dysprosium 2) and/or<br />

neodym 2) , surcharges are calculated on a daily basis using the<br />

so-called metal factor for products containing these raw<br />

materials. A surcharge for the respective raw material is calculated<br />

as a supplement to the price of a product if the basic<br />

official price of the raw material in question is exceeded.<br />

The surcharges are calculated in accordance with the following<br />

criteria:<br />

• Basic official price of the raw material<br />

Basic official price from the day prior to receipt of the order or<br />

prior to release order (daily price) for 3)<br />

- Silver (sales price, processed)<br />

- Gold (sales price, processed)<br />

and for 4)<br />

- Copper (lower DEL notation + 1 %)<br />

- Aluminum (aluminum in cables)<br />

- Lead (lead in cables)<br />

• Metal factor of the products<br />

Certain products are displayed with a metal factor. The metal<br />

factor determines the official price (for those raw materials<br />

concerned) as of which the metal surcharges are applied and<br />

the calculation method used (weight or percentage method).<br />

An exact explanation is given below.<br />

Structure of the metal factor<br />

The metal factor consists of several digits; the first digit indicates<br />

whether the percentage method of calculation refers to the list<br />

price or a possible discounted price (customer net price) (L = list<br />

price / N = customer net price).<br />

The remaining digits indicate the method of calculation used for<br />

the respective raw material. If no surcharge is added for a raw<br />

material, a "-" is used.<br />

1st digit List or customer net price using the percentage method<br />

2nd digit for silver (AG)<br />

3rd digit for copper (CU)<br />

4th digit for aluminum (AL)<br />

5th digit for lead (PB)<br />

6th digit for gold (AU)<br />

7th digit for dysprosium (Dy) 2)<br />

8th digit for neodym (Nd) 2)<br />

Weight method<br />

The weight method uses the basic official price, the daily price<br />

and the raw material weight. In order to calculate the surcharge,<br />

the basic official price must be subtracted from the daily price.<br />

The difference is then multiplied by the raw material weight.<br />

The basic official price can be found in the table below using the<br />

number (1 to 9) of the respective digit of the metal factor. The raw<br />

material weight can be found in the respective product descriptions.<br />

Percentage method<br />

Use of the percentage method is indicated by the letters A-Z at<br />

the respective digit of the metal factor.<br />

The surcharge is increased - dependent on the deviation of the<br />

daily price compared with the basic official price - using the percentage<br />

method in "steps" and consequently offers surcharges<br />

that remain constant within the framework of this "step range". A<br />

higher percentage rate is charged for each new step. The respective<br />

percentage level can be found in the table below.<br />

Metal factor examples<br />

L E A – – – – –<br />

N – A 6 – – – –<br />

– – 3 – – – – –<br />

Basis for % surcharge: List price<br />

Silver Basis 150 €, Step 50 €, 0.5 %<br />

Copper Basis 150 €, Step 50 €, 0.1 %<br />

No surcharge for aluminum<br />

No surcharge for lead<br />

No surcharge for gold<br />

No surcharge for dysprosium<br />

No surcharge for neodym<br />

Basis for % surcharge: Customer net price<br />

No surcharge for silver<br />

Copper Basis 150 €, Step 50 €, 0.1 %<br />

Aluminum acc. to weight, basic offic. price 225 €<br />

No surcharge for lead<br />

No surcharge for gold<br />

No surcharge for dysprosium<br />

No surcharge for neodym<br />

No basis necessary<br />

No surcharge for silver<br />

Copper acc. to weight, basic official price 150 €<br />

No surcharge for aluminum<br />

No surcharge for lead<br />

No surcharge for gold<br />

No surcharge for dysprosium<br />

No surcharge for neodym<br />

1) Refer to the separate explanation on the next page regarding the raw materials dysprosium and neodym (= rare earths).<br />

2) For a different method of calculation, refer to the separate explanation for these raw materials on the next page.<br />

3) Source: Umicore, Hanau (www.metalsmanagement.umicore.com).<br />

4) Source: Schutzvereinigung DEL-Notiz e.V. (www.del-notiz.org).<br />

5/8 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Appendix<br />

Metal surcharges<br />

1) 2)<br />

■ Explanation of the raw material/metal surcharges for dysprosium and neodym (rare earths)<br />

Surcharge calculation<br />

To compensate for variations in the price of the raw materials<br />

silver 1) , copper 1) , aluminum 1) , lead 1) , gold 1) , dysprosium<br />

and/or neodym, surcharges are calculated on a daily basis<br />

using the so-called metal factor for products containing these<br />

raw materials. The surcharge for dysprosium and neodym is<br />

calculated as a supplement to the price of a product if the basic<br />

official price of the raw material in question is exceeded.<br />

The surcharge is calculated in accordance with the following<br />

criteria:<br />

• Basic official price of the raw material 2)<br />

Three-month basic average price (see below) in the period<br />

before the quarter in which the order was received or the release<br />

order took place (= average official price) for<br />

- dysprosium (Dy metal, 99 % min. FOB China; USD/kg)<br />

- neodym (Nd metal, 99 % min. FOB China; USD/kg)<br />

• Metal factor of the products<br />

Certain products are displayed with a metal factor. The metal<br />

factor indicates (for those raw materials concerned) the basic<br />

official price as of which the surcharges for dysprosium and<br />

neodym are calculated using the weight method. An exact explanation<br />

of the metal factor is given below.<br />

Three-month average price<br />

The prices of rare earths vary according to the foreign currency,<br />

and there is no freely accessible stock exchange listing. This<br />

makes it more difficult for all parties involved to monitor changes<br />

in price. In order to avoid continuous adjustment of the surcharges,<br />

but to still ensure fair, transparent pricing, an average<br />

price is calculated over a three-month period using the average<br />

monthly foreign exchange rate from USD to EUR (source: European<br />

Central Bank). Since not all facts are immediately available<br />

at the start of each month, a one-month buffer is allowed before<br />

the new average price applies.<br />

Examples of calculation of the average official price:<br />

Period for calculation of<br />

the average price:<br />

Sep 2012 - Nov 2012<br />

Dec 2012 - Feb 2013<br />

Mar 2013 - May 2013<br />

Jun 2013 - Aug 2013<br />

Period during which the order/release order is<br />

effected and the average price applies:<br />

Q1 in 2013 (Jan - Mar)<br />

Q2 in 2013 (Apr - Jun)<br />

Q3 in 2013 (Jul - Sep)<br />

Q4 in 2013 (Oct - Dec)<br />

Weight method<br />

The weight method uses the basic official price, the average<br />

price and the raw material weight. In order to calculate the surcharge,<br />

the basic official price must be subtracted from the average<br />

price. The difference is then multiplied by the raw material<br />

weight.<br />

The basic official price can be found in the table below using the<br />

number (1 to 9) of the respective digit of the metal factor. Your<br />

Sales contact can inform you of the raw material weight.<br />

Metal factor examples<br />

– – – – – – 7 1<br />

No basis necessary<br />

No surcharge for silver<br />

No surcharge for copper<br />

No surcharge for aluminum<br />

No surcharge for lead<br />

No surcharge for gold<br />

Dysprosium acc. to weight, basic official price<br />

300 €<br />

Neodym acc. to weight, basic official price 50 €<br />

Structure of the metal factor<br />

The metal factor consists of several digits; the first digit is not<br />

relevant to the calculation of dysprosium and neodym.<br />

The remaining digits indicate the method of calculation used for<br />

the respective raw material. If no surcharge is added for a raw<br />

material, a "-" is used.<br />

1st digit List or customer net price using the percentage method<br />

2nd digit for silver (AG) 1)<br />

3rd digit for copper (CU) 1)<br />

4th digit for aluminum (AL) 1)<br />

5th digit for lead (PB) 1)<br />

6th digit for gold (AU) 1)<br />

7th digit for dysprosium (Dy)<br />

8th digit for neodym (Nd)<br />

5<br />

1) For a different method of calculation, refer to the separate explanation for these raw materials on the previous page.<br />

2) Source: Asian Metal Ltd (www.asianmetal.com)<br />

Siemens D 31.5 · March <strong>2020</strong><br />

5/9


© Siemens <strong>2020</strong><br />

Appendix<br />

Metal surcharges<br />

5<br />

■ Values of the metal factor<br />

Percentage<br />

method<br />

Basic official<br />

price<br />

in €<br />

Step range<br />

in €<br />

% surcharge<br />

1st step<br />

% surcharge<br />

2nd step<br />

% surcharge<br />

3rd step<br />

% surcharge<br />

4th step<br />

Price in € Price in € Price in € Price in €<br />

150.01 - 200.00 200.01 - 250.00 250.01 - 300.00 300.01 - 350.00<br />

% surcharge<br />

per additional<br />

step<br />

A 150 50 0.1 0.2 0.3 0.4 0.1<br />

B 150 50 0.2 0.4 0.6 0.8 0.2<br />

C 150 50 0.3 0.6 0.9 1.2 0.3<br />

D 150 50 0.4 0.8 1.2 1.6 0.4<br />

E 150 50 0.5 1.0 1.5 2.0 0.5<br />

F 150 50 0.6 1.2 1.8 2.4 0.6<br />

G 150 50 1.0 2.0 3.0 4.0 1.0<br />

H 150 50 1.2 2.4 3.6 4.8 1.2<br />

I 150 50 1.6 3.2 4.8 6.4 1.6<br />

J 150 50 1.8 3.6 5.4 7.2 1.8<br />

175.01 - 225.00 225.01 - 275.00 275.01 - 325.00 325.01 - 375.00<br />

O 175 50 0.1 0.2 0.3 0.4 0.1<br />

P 175 50 0.2 0.4 0.6 0.8 0.2<br />

R 175 50 0.5 1.0 1.5 2.0 0.5<br />

225.01 - 275.00 275.01 - 325.00 325.01 - 375.00 375.01 - 425.00<br />

S 225 50 0.2 0.4 0.6 0.8 0.2<br />

U 225 50 1.0 2.0 3.0 4.0 1.0<br />

V 225 50 1.0 1.5 2.0 3.0 1.0<br />

W 225 50 1.2 2.5 3.5 4.5 1.0<br />

150.01 - 175.00 175.01 - 200.00 200.01 - 225.00 225.01 - 250.00<br />

Y 150 25 0.3 0.6 0.9 1.2 0.3<br />

400.01 - 425.00 425.01 - 450.00 450.01 - 475.00 475.01 - 500.00<br />

Z 400 25 0.1 0.2 0.3 0.4 0.1<br />

L<br />

N<br />

Weight<br />

method<br />

Price basis (1st digit)<br />

Basic official price in €<br />

Calculation based on the list price<br />

Calculation based on the customer net price (discounted list price)<br />

1 50 Calculation based on raw material weight<br />

2 100<br />

3 150<br />

4 175<br />

5 200<br />

6 225<br />

7 300<br />

8 400<br />

9 555<br />

Miscellaneous<br />

- No metal surcharge<br />

5/10 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Appendix<br />

Conditions of sale and delivery<br />

■ 1. General Provisions<br />

By using this catalog you can purchase products (hardware,<br />

software and services) described therein from Siemens Aktiengesellschaft<br />

subject to the following Terms and Conditions of<br />

Sale and Delivery (hereinafter referred to as "T&C"). Please note<br />

that the scope, the quality and the conditions for supplies and<br />

services, including software products, by any Siemens entity<br />

having a registered office outside Germany, shall be subject<br />

exclusively to the General Terms and Conditions of the<br />

respective Siemens entity. The following T&C apply exclusively<br />

for orders placed with Siemens Aktiengesellschaft, Germany.<br />

1.1 For customers with a seat or registered office in<br />

Germany<br />

For customers with a seat or registered office in Germany, the<br />

following terms and conditions apply subordinate to T&C:<br />

• for products, which include specific terms and conditions in<br />

the description text, these specific terms and conditions shall<br />

apply and subordinate thereto,<br />

• for installation work the "General Conditions for Erection<br />

Works Germany" 1) ("Allgemeine Montagebedingungen <br />

Deutschland" (currently only available in German)) and/or<br />

• for stand-alone software products and software products<br />

forming a part of a product or project, the "General License<br />

Conditions for Software Products for Automation and Drives<br />

for Customers with a Seat or registered Office in Germany" 1)<br />

and/or<br />

• for consulting services the "General Terms and Conditions for<br />

Consulting Services of the Division DF Germany" 1) and/or<br />

• for other supplies and/or services the "General Conditions for<br />

the Supply of Products and Services of the Electrical and<br />

Electronics Industry" 1) .<br />

In case such supplies and/or services should contain Open<br />

Source Software, the conditions of which shall prevail over the<br />

"General Conditions for the Supply of Products and Services<br />

of the Electrical and Electronics Industry" 1) , a notice will be<br />

contained in the scope of delivery in which the applicable<br />

conditions for Open Source Software are specified. This shall<br />

apply mutatis mutandis for notices referring to other third party<br />

software components.<br />

1.2 For customers with a seat or registered office outside<br />

Germany<br />

For customers with a seat or registered office outside Germany,<br />

the following terms and conditions apply subordinate to T&C:<br />

• for products, which include specific terms and conditions in<br />

the description text, these specific terms and conditions shall<br />

apply and subordinate thereto,<br />

• for services the "International Terms & Conditions for<br />

Services" 1) supplemented by "Software Licensing<br />

Conditions" 1) and/or<br />

• for consulting services the "General Terms and Conditions for<br />

Consulting Services of the Division DF Germany" 1) and/or<br />

• for other supplies of hard- and software the "International<br />

Terms & Conditions for Products" 1) supplemented by<br />

"Software Licensing Conditions" 1)<br />

1.3 For customers with master or framework agreement<br />

To the extent our supplies and/or services offered are covered<br />

by an existing master or framework agreement, the terms and<br />

conditions of that agreement shall apply instead of T&C.<br />

■ 2. Prices<br />

The prices are in € (Euro) ex point of delivery, exclusive of<br />

packaging.<br />

The sales tax (value added tax) is not included in the prices. It<br />

shall be charged separately at the respective rate according to<br />

the applicable statutory legal regulations.<br />

Prices are subject to change without prior notice. We will charge<br />

the prices valid at the time of delivery.<br />

To compensate for variations in the price of raw materials (e.g.<br />

silver, copper, aluminum, lead, gold, dysprosium and neodym),<br />

surcharges are calculated on a daily basis using the so-called<br />

metal factor for products containing these raw materials. A<br />

surcharge for the respective raw material is calculated as a<br />

supplement to the price of a product if the basic official price of<br />

the raw material in question is exceeded.<br />

The metal factor of a product indicates the basic official price<br />

(for those raw materials concerned) as of which the surcharges<br />

on the price of the product are applied, and with what method of<br />

calculation.<br />

You will find a detailed explanation of the metal factor on the<br />

page headed "Metal surcharges".<br />

To calculate the surcharge (except in the cases of dysprosium<br />

and neodym), the official price from the day prior to that on which<br />

the order was received or the release order was effected is used.<br />

To calculate the surcharge applicable to dysprosium and<br />

neodym ("rare earths"), the corresponding three-month basic<br />

average price in the quarter prior to that in which the order was<br />

received or the release order was effected is used with a onemonth<br />

buffer (details on the calculation can be found in the<br />

explanation of the metal factor).<br />

■ 3. Additional Terms and Conditions<br />

The dimensions are in mm. In Germany, according to the<br />

German law on units in measuring technology, data in inches<br />

apply only to devices for export.<br />

Illustrations are not binding.<br />

Insofar as there are no remarks on the individual pages of this<br />

catalog – especially with regard to data, dimensions and weights<br />

given – these are subject to change without prior notice.<br />

5<br />

1) The text of the Terms and Conditions of Siemens AG can be<br />

downloaded at<br />

https://mall.industry.siemens.com/legal/ww/en/<br />

terms_of_trade_en.pdf<br />

Siemens D 31.5 · March <strong>2020</strong><br />

5/11


© Siemens <strong>2020</strong><br />

Appendix<br />

Conditions of sale and delivery<br />

■ 4. Export regulations<br />

We shall not be obligated to fulfill any agreement if such<br />

fulfillment is prevented by any impediments arising out of<br />

national or international foreign trade or customs requirements<br />

or any embargoes and/or other sanctions.<br />

Export may be subject to license. We shall indicate in the<br />

delivery details whether licenses are required under German,<br />

European and US export lists.<br />

Our products are <strong>control</strong>led by the U.S. Government (when<br />

labeled with "ECCN" unequal "N") and authorized for export only<br />

to the country of ultimate destination for use by the ultimate<br />

consignee or end-user(s) herein identified. They may not be<br />

resold, transferred, or otherwise disposed of, to any other<br />

country or to any person other than the authorized ultimate<br />

consignee or end-user(s), either in their original form or after<br />

being incorporated into other items, without first obtaining<br />

approval from the U.S. Government or as otherwise authorized<br />

by U.S. law and regulations.<br />

The export indications can be viewed in advance in the<br />

description of the respective goods on the Industry Mall, our<br />

online catalog system. Only the export labels "AL" and "ECCN"<br />

indicated on order confirmations, delivery notes and invoices<br />

are authoritative.<br />

Products labeled with "AL" unequal "N" are subject to<br />

European / national export authorization. Products without label,<br />

with label "AL:N" / "ECCN:N", or label "AL:9X9999" /<br />

"ECCN: 9X9999" may require authorization from responsible<br />

authorities depending on the final end-use, or the destination.<br />

If you transfer goods (hardware and/or software and/or<br />

technology as well as corresponding documentation, regardless<br />

of the mode of provision) delivered by us or works and services<br />

(including all kinds of technical support) performed by us to a<br />

third party worldwide, you must comply with all applicable national<br />

and international (re-)export <strong>control</strong> regulations.<br />

If required for the purpose of conducting export <strong>control</strong> checks,<br />

you (upon request by us) shall promptly provide us with all information<br />

pertaining to the particular end customer, final disposition<br />

and intended use of goods delivered by us respectively<br />

works and services provided by us, as well as to any export<br />

<strong>control</strong> restrictions existing in this relation.<br />

The products listed in this catalog may be subject to<br />

European/German and/or US export regulations. Any export<br />

requiring approval is therefore subject to authorization by the<br />

relevant authorities.<br />

Errors excepted and subject to change without prior notice.<br />

5<br />

5/12 Siemens D 31.5 · March <strong>2020</strong>


© Siemens <strong>2020</strong><br />

Selection and ordering at Siemens<br />

Industry Mall, downloading and ordering catalogs<br />

Easy product selection and ordering: Industry Mall<br />

Industry Mall<br />

The Industry Mall is a Siemens AG Internet ordering platform.<br />

It provides you with online access to a comprehensive product<br />

spectrum that is presented in an informative, well-organized<br />

way.<br />

Powerful search functions help you select the required products,<br />

while configurators enable you to configure complex product<br />

and system components quickly and easily. CAx data are also<br />

available for you to use.<br />

Data transfer allows the entire procedure, from selection through<br />

ordering to tracking and tracing, to be carried out online.<br />

Availability checks, individual customer discounting, and<br />

quotation preparation are also possible.<br />

www.siemens.com/industrymall<br />

Downloading catalogs<br />

Siemens Industry Online Support<br />

You can download catalogs and brochures in PDF format from<br />

Siemens Industry Online Support without having to register.<br />

The filter box makes it possible to perform targeted searches.<br />

www.siemens.com/industry-catalogs<br />

Ordering printed catalogs<br />

Please contact your local Siemens branch if you are interested<br />

in ordering printed catalogs.<br />

Addresses can be found at<br />

www.siemens.com/automation-contact<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>


© Siemens <strong>2020</strong><br />

Get more information<br />

SINAMICS G120X infrastructure converters<br />

for HVAC/Water/Wastewater:<br />

www.siemens.com/sinamics-g120x<br />

SIMOTICS electric motors:<br />

www.siemens.com/simotics<br />

Motion Control Systems and Solutions for production<br />

machine and machine tool equipment:<br />

www.siemens.com/<strong>motion</strong><strong>control</strong><br />

Local partners worldwide:<br />

www.siemens.com/automation-contact<br />

Published by<br />

Siemens AG<br />

Digital Industries<br />

Motion Control<br />

Postfach 31 80<br />

91050 Erlangen, Germany<br />

PDF (Article No. E86060-K5531-A151-A3-7600)<br />

V6.MKKATA.GMC.106<br />

KG <strong>03</strong>20 126 En<br />

Produced in Germany<br />

© Siemens <strong>2020</strong><br />

For the U.S. published by<br />

Siemens Industry Inc.<br />

5300 Triangle Parkway<br />

Norcross, GA 30092<br />

United States<br />

Subject to changes and errors. The information given in this document<br />

only contains general descriptions and/or performance features<br />

which may not always specifically reflect those described, or which<br />

may undergo modification in the course of further development of<br />

the products. The requested performance features are binding only<br />

when they are expressly agreed upon in the concluded contract.<br />

All product designations may be trademarks or product names of<br />

Siemens AG or other companies whose use by third parties for their<br />

own purposes could violate the rights of the owners.<br />

Security information<br />

Siemens provides products and solutions with industrial<br />

security functions that support the secure operation of<br />

plants, systems, machines and networks.<br />

In order to protect plants, systems, machines and networks<br />

against cyber threats, it is necessary to implement – and<br />

continuously maintain – a holistic, state-of-the-art industrial<br />

security concept. Siemens’ products and solutions<br />

constitute one element of such a concept.<br />

Customers are responsible for preventing unauthorized<br />

access to their plants, systems, machines and networks.<br />

Such systems, machines and components should only be<br />

connected to an enterprise network or the internet if and<br />

to the extent such a connection is necessary and only<br />

when appropriate security measures (e.g. firewalls and/or<br />

network segmentation) are in place.<br />

For additional information on industrial security measures<br />

that may be implemented, please visit<br />

https://www.siemens.com/industrialsecurity<br />

Siemens’ products and solutions undergo continuous<br />

development to make them more secure. Siemens strongly<br />

recommends that product updates are applied as soon as<br />

they are available and that the latest product versions are<br />

used. Use of product versions that are no longer supported,<br />

and failure to apply the latest updates may increase<br />

customer’s exposure to cyber threats.<br />

To stay informed about product updates, subscribe to the<br />

Siemens Industrial Security RSS Feed under<br />

https://www.siemens.com/industrialsecurity<br />

<strong>Update</strong> <strong>08</strong>/<strong>2020</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!