The essential guideof Automation& Control2011


The go to guidefor the most efficient selectionMake the most of your energy


ContentsDetectionp Photo-electric, inductive and ultrasonic sensorsp Limit switchesp Sensors for pressure controlp Rotary encoders and radio frequency identificationOperator dialogp Control and signalling unitsp Human/Machine Interfaces12Automationp Relaysp Programmable controllersp Automation platformsp Configuration softwareMotion and Drivesp Soft starters and variable speed drivesp Servo drives, Servo motors and Motion controllersp Stepper drives and motors, integrated drivesp Linear motion axe and Multi-axis systemsMotor controlp Motor control componentsp Components for power control applications345Power suppliesp Power suppliesp Transformersp Connection6Interfaces and I/Op Distributed Inputs/Outputsp Interfacesp Accessories and Cabling7Networks connectivity and Web serversp ConneXium cabling systemp AS-Interface cabling systemp Servers and Gateways8Machine safetyp Safety solutions provide maximum protection in all the safetyfunctions of your automation system9Explosive atmospheresp Detectionp Operator dialogp Machine safetyp Automation10


Innovative and simple products for all AutomInterfaces & I/OConnectorsCable-ends, terminal blocsInterfacesPlug-in relays, analogconverters, discreteinterfacesPre-wired interfaces,IP20/IP67 distributed I/OAS-InterfaceIP20/IP67 interfaces,cables, repeaters,accessories,adressing andadjustment terminalsMachine safetySafety monitors andcontrollers on AS-InterfaceSoftwareSoftware to design andinstall AS-Interface system,safety monitors andcontrollers on AS-Interfaceprogramming softwareMounting systemsEnclosuresWall mounted enclosuresFloor standing enclosures,suite type cubiclesIndustrial boxesEquipment and accessoriesThermal control equipmentPower splitter blocksMounting accessoriesPower suppliesPower suppliesSwitch mode powersuppliesFiltered rectified powersupplies, transformersAS-InterfacePower suppliesAutomationRelaysPlug-in relays, electronictimers, control relays,countsSmart relaysPLCs, PC based control,distributed I/OProgrammable controllersPLC platformsPC based controlDistributed I/O, I/OcontrollersAS-InterfaceMaster modules forModicon PLCsMachine safetySafety PLCs, controllersand modulesSoftwarePLCs and safety controllersprogramming softwareSystems &ArchitecturesConnecting EthernetdevicesWeb-enabling PLCson EthernetApplication protocolsand field buses


ation and Control functionsMotion & DrivesSoft starters, drivesand linear axesSoft startersVariable speed drivesMotion controllersServo drives and motorsStepper drives and motorsIntegrated drivesSingle axes and multi-axissystemsSoftwareSetup and ProgrammingsoftwareMotor controlMotor startersContactorsCircuit breakers, fuse carriersThermal relaysCombinations,motor controllersMounting solutionsMotor starter mounting kitAS-InterfaceMotor controllers,enclosures, variable speeddrivesMachine safetySwitch disconnectors,thermal-magnetic motorcircuit breakers, enclosedstartersSoftwareMotor control programmingsoftwareSoftware toolsGlobal softwareGeneration of applicationsystemsApplication controlCollaborative developmentDedicated softwareSee Software in otherfunctionsOperator dialogControl & signalling unitsControl and signalling units,Cam switches,Beacons and indicator banksHuman machine interfacesOperator interface terminals,industrial PCs, Web servers,HMI and SCADA PC-basedsoftwareControl stations, mountingsolutionsControl and pendant stations,front panels mounting kitsAS-InterfaceControl stations, keypads,beaconsMachine safetyEmergency stops, controlstations, enabling switches,foot switchesSoftwareOperator terminal softwareDetectionSensorsLimit switchesProximity sensorsPhoto-electric and ultrasonicsensorsPressure switchesRotary encodersRFIDInductive identificationMachine safetySwitches, light curtains,matsSoftwareSafety mats configurationsoftware


<strong>OsiSense</strong><strong>OsiSense</strong> is the range name for allSchneider Electric’s detection products.With monitoring, counting and controlexpertise built into its limit switches,sensors, rotary encoders and RFIDsolutions, Schneider Electric has awide range of products to meet allyour detection needs, making it easyfor you to choose, procure, install andmaintain your products.


DetectionThis document is a selection ofthe top selling products.1Limit switches .....................................................................................................................................1/2 to 1/11Detection by contact of rigid objectsObject speed ≤ 1.5 m/s, <strong>OsiSense</strong> XCSensors for pressure control ................................................................................................... 1/12 to 1/17Detection by contact with fluidElectronic or electromechanical pressure and vacuum switches,pressure sensors, <strong>OsiSense</strong> XMInductive proximity sensors ...................................................................................................... 1/18 to 1/28Detection without contact of metal objectsSensor / object distance ≤ 60 mm, <strong>OsiSense</strong> <strong>XS</strong>Capacitive proximity sensors .............................................................................................................. 1/29Detection of insulating materials or conductive materialsSpecific products for particular applications, <strong>OsiSense</strong> XTPhoto-electric sensors .................................................................................................................. 1/30 to 1/41Detection without contact of any objectDetection from a few millimetres to several tens of metres, <strong>OsiSense</strong> XUUltrasonic sensors ........................................................................................................................ 1/42 and 1/43Detection without contact of any object of any materialDetection from a few millimetres up to 8 metres, <strong>OsiSense</strong> XXRotary encoders ............................................................................................................................... 1/44 and 1/45Opto-electronic detectionIncremental or absolute - single turn and multiturn, <strong>OsiSense</strong> XCCRadio frequency identification ............................................................................................. 1/46 and 1/4713.56 MHz RFID detectionComplete range of RFID tags and compact stations, <strong>OsiSense</strong> XGSensors for explosive atmospheresSee chapter 10 “Explosive Atmospheres”23456789101/1


131422 21131422 21<strong>OsiSense</strong> XCLimit switchesCompact and miniature, complete switches(variable composition, see pages 34-35)XCMDBKBUGN-YE2-pole contactNC+NOsnap actionXCKT2-pole contactNC+NOsnap action1BKWHBKBNBUGN-YE2-pole contactNC+NOslow breakBKWHBNMiniature XCMD metal, pre-cabled; fixing by the body or by the head2Type of operatorMetalend plungerSteel rollerplungerThermoplasticroller leverSteelroller leverVariable lengththermoplasticroller leverM12 headmetalend plunger345678910Mechanical durability (millions of operating cycles) 10 10 10 10 10 10Actuation speed (in m/s) 0.5 0.5 1.5 1.5 1.5 0.5Switches conforming to standard IEC 947-5-1 section 3Product certificationCE - UL - CSA - CCCDegree of protection conforming to IEC 60529 IP 66 and IP 67Rated operational characteristics AC-15; B300 (Ue = 240 V, Ie = 1.5 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)Fixing centres (mm) 20 M12 x 1Body dimensions (mm) W x D x H 30 x 16 x 50Connection Cable Pre-cabled, adjustable direction, length = 1 m (other lengths available on request)Complete switch 2-pole NC+NO snap action XCMD2110L1 XCMD2102L1 XCMD2115L1 XCMD2116L1 XCMD2145L1 XCMD21F0L12-pole NC+NO break before make, slow break XCMD2510L1 XCMD2502L1 XCMD2515L1 XCMD2516L1 XCMD2545L1 XCMD25F0L1ConnectorM12Complete switch NC+NO snap action (M12-5 pins) XCMD2110C12 XCMD2102C12 XCMD2115C12 XCMD2116C12 XCMD2145C12 XCMD21F0C121C/O snap action (M12-4 pins) (1) XCMD2110M12 XCMD2102M12 XCMD2115M12 XCMD2116M12 XCMD2145M12 XCMD21F0M12(1) Although their design is identical to the pre-cabled switches, the switches incorporating an M12 4-pin connector cannot be marked with the symbol because they are single-pole C/O.Positive opening operation.XCKP/XCKD131422 212-pole contactNC+NOsnap action2-pole contactNC+NOslow breakPositive opening operation.Compact XCKD metal and XCKP plastic conforming to standard EN 50047Type of operatorMetalend plungerSteelroller plungerThermoplasticroller lever plunger,horizontal actuationin 1 directionM18 headmetalend plungerISO entry(to EN 50262)Mechanical durability (millions of operating cycles) 15 10 15 10 10Actuation speed (in m/s) 0.5 0.5 1 0.5 0.5Switches conforming to standard IEC 947-5-1 section 3M18 headsteelroller plungerProduct certificationCE - CSA - CCC - GOSTDegree of protection conforming to IEC 60529 IP 66 and IP 67Rated operational characteristics AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)Cable entry1 tapped entry for ISO M16 x 1.5 cable gland (3) or M12 connectorFixing centres (mm) 20 20 20 M18 x 1 M18 x 1Body dimensions (mm) W x D x H 31 x 30 x 65Metal switchesComplete switch 2-pole NC+NO snap action XCKD2110P16 XCKD2102P16 XCKD2121P16 XCKD21H0P16 XCKD21H2P162-pole NC+NO break before make, slow break XCKD2510P16 XCKD2502P16 XCKD2521P16 XCKD25H0P16 XCKD25H2P162-pole NC+NO snap action (M12-5 pins) XCKD2110M12 XCKD2102M12 XCKD2121M12 XCKD21H0M12 XCKD21H2M12Plastic, double insulated switchesComplete switch 2-pole NC+NO snap action XCKP2110P16 XCKP2102P16 XCKP2121P16 XCKP21H0P16 XCKP21H2P162-pole NC+NO break before make, slow break XCKP2510P16 XCKP2502P16 XCKP2521P16 XCKP25H0P16 XCKP25H2P162-pole NC+NO snap action (M12-4 pins) XCKP2110M12 XCKP2102M12 XCKP2121M12 XCKP21H0M12 XCKP21H2M12(3) For Pg 11 cable entries, replace P16 by G11. Example: XCKD2110P16 becomes XCKD2110G11.For other cable entries, see customised assembly on page 1/34.1/2Other versions: please consult our Customer Care Centre.


ISO entry(to EN 50262)1Compact XCKT plastic, 2 cable entriesRetractablesteel roller leverplungerM12 headsteelroller plunger“Cat’s whisker”Metalend plungerSteelroller plungerThermoplasticroller leverThermoplasticroller leverplunger, horizontalactuation“Cat’s whisker”10 10 5 15 10 10 15 5 50,5 0.1 1 0.5 0.5 1.5 1 1 1“Cat’s whisker”– – –CE - CSA - CCC - GOSTIP 66 and IP 67AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)20 M12 x 1 20 20 or 4058 x 30 x 512 tapped entries for ISO M16 x 1.5 cable gland (2)XCMD2124L1 XCMD21F2L1 XCMD2106L1 XCKT2110P16 XCKT2102P16 XCKT2118P16 XCKT2145P16 XCKT2121P16 XCKT2106P16XCMD2524L1 XCMD25F2L1 XCMD2506L1 – – – – – –234XCMD2124C12 XCMD21F2C12 XCMD2106C12 – – – – – –XCMD2124M12 XCMD21F2M12 XCMD2106M12 – – – – – –(2) For Pg 11 cable entries, replace P16 by G11. Example: XCKT2110P16 becomes XCKT2110G11.ISO entry(to EN 50262)56Thermoplasticroller leverVariable lengthThermoplasticroller leverThermoplasticroller leverØ 50 mm“Cat’s whisker”Application - XCPR and XCDR with manual resetMetalend plungerSteelroller plungerThermoplastic Thermoplasticroller lever plunger, roller lever plunger,horizontal actuation vertical actuationin 1 direction in 1 direction10 10 10 5 1 1 1 1 11.5 1.5 1.5 1 0.5 0.5 1 1 1.5–CE - CSA - CCC - GOSTIP 66 and IP 67AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)1 tapped entry for ISO M20 x 1.5 cable gland (4)20 20 20 20 20 20 20 20 2031 x 30 x 95Thermoplasticroller lever789XCKD2118P16 XCKD2145P16 XCKD2139P16 XCKD2106P16 XCDR2110P20 XCDR2102P20 XCDR2121P20 XCDR2127P20 XCDR2118P20XCKD2518P16 XCKD2545P16 XCKD2539P16 XCKD2506P16 XCDR2510P20 XCDR2502P20 XCDR2521P20 XCDR2527P20 XCDR2518P20XCKD2118M12 XCKD2145M12 XCKD2139M12 XCKD2106M12 – – – – –XCKP2118P16 XCKP2145P16 XCKP2139P16 XCKP2106P16 XCPR2110P20 XCPR2102P20 XCPR2121P20 XCPR2127P20 XCPR2118P20XCKP2518P16 XCKP2545P16 XCKP2539P16 XCKP2506P16 XCPR2510P20 XCPR2502P20 XCPR2521P20 XCPR2527P20 XCPR2518P20XCKP2118M12 XCKP2145M12 XCKP2139M12 XCKP2106M12 – – – – –(4) For Pg 13.5 cable entries, replace P20 by G13. Example: XCDR2110P20 becomes XCDR2110G13.For other cable entries, see customised assembly on page 1/34.10Other versions: please consult our Customer Care Centre.1/3


<strong>OsiSense</strong> XCLimit switchesCustomised assembly of miniature and compactHeads - common to miniature and compact bodies1Metal plunger and multi-directional headsDescriptionMetalend plungerMetal end plungerwith protectiveelastomer bootSteelroller plungerRetractable steelroller lever plungerThermoplasticroller lever plunger,horizontal actuation234Reference ZCE10 ZCE11 ZCE02 ZCE24 (2) ZCE21Metal rotary heads and leversDescriptionRotary headwithout lever,spring return, foractuation fromLH or RH sideThermoplasticroller lever,track:24/31 mm (ZCMD)29/36 mm (ZCD/P/T)Steelroller lever,track:24/31 mm (ZCMD)29/36 mm (ZCD/P/T)Thermoplasticroller lever,track:16/39 mm (ZCMD)21/44 mm (ZCD/P/T)Steelroller lever,track:16/39 mm (ZCMD)21/44 mm (ZCD/P/T)56BodiesReference ZCE01 ZCY15 (2) ZCY16 (2) ZCY25 (2) ZCY25 (2)(1) Recommended for use with bodies: ZCD... / ZCP... / ZCT... (2) Recommended for use with bodies: ZCMD...Miniature789Type of contactConnection of miniature bodiesSpecific pre-cabledconnection componentsBKBUBKWHBNGN-YE2-poleNO+NCSnap actionBKRDBUBKWHRDWHBNGN-YE3-pole2NC+1NOSnap actionBKBUBKWHBNGN-YE2-poleNC+NOSlow breakBKRDBUBKWHRDWHBN3-pole2NC+1NOSlow breakGN-YEBKBUBKWHBNGN-YE2-poleNO+NCSnap action2-poleNC+NOSnap actionConnector 5 pin1-pole1C/OSnap actionConnector 4 pinOption: pre-wired M12connector, L = 2 m5-pin 4-pinBK-WH BKRD-WH RDBUBNVTVT-WHGN-YE4-pole2NC+2NOSnap actionReference of metal body ZCMD21 ZCMD39 ZCMD25 ZCMD37 – ZCMD21C12 ZCMD21M12 –Cable L = 1 m – – – – ZCMD21L1 (3) – – ZCMD41L1L = 2 m – – – – ZCMD21L2 (3) – – ZCMD41L2L = 5 m – – – – ZCMD21L5 (3) – – ZCMD41L5(3) For contact 2-pole NC+NO slow break, replace 21 by 25. Example: ZCMD21L1 becomes ZCMD25L110forZCMD21forZCMD39forZCMD25forZCMD37L = 1 m ZCMC21L1 ZCMC39L1 ZCMC25L1 ZCMC37L1L = 2 m ZCMC21L2 ZCMC39L2 ZCMC25L2 ZCMC37L2L = 5 m ZCMC21L5 ZCMC39L5 ZCMC25L5 ZCMC37L5 XZCP1164L2 XZCP1141L2Positive opening operation.1/4Other versions: please consult our Customer Care Centre.


switchesThermoplasticroller lever plunger,vertical actuationM12 headmetalend plungerM18 headmetalend plungerM12 headsteelroller plungerM18 headsteelroller plungerSpring rodSpring rod withplastic end“Cat’s whisker”12ZCE27 ZCEF0(2) ZCEH0(1) ZCEF2(2) ZCEH2(1) ZCE08 ZCE07 ZCE063Thermoplasticroller lever,track:20/36 mm (ZCMD)24/40 mm (ZCD/P/T)Steelroller lever,track:20/36 mm (ZCMD)24/40 mm (ZCD/P/T)Ceramicroller leverVariable lengththermoplasticroller leverRound,glass fibrerod leverØ 3 mmL = 125 mmMetalspring-rodleverThermoplasticroller leverØ 50 mmAdjustable thermoplasticroller leverØ 50 mm45ZCY18(1) ZCY19(1) ZCY22 ZCY45 ZCY55 ZCY91 ZCY39 ZCY49Compact67Type of contactInterchangeableoutlet for cablegland131422 212-pole NC+NOSnap action32 31Connection of compact bodies22 213-pole2NC+1NOSnap action1314131422 212-pole NC+NOSlow break12 1122 212-pole NC+NCSlow break131423242-pole NO+NOSlow breakDescription For ISO M16 For ISO M20 For Pg 11 For Pg 13.5 For 1/2" NPT For PF 1/2 (G12)cable gland cable gland cable gland cable gland cable gland cable glandMetal ZCDEP16 ZCDEP20 ZCDEG11 ZCDEG13 ZCDEN12 ZCDEF12Plastic ZCPEP16 ZCPEP20 ZCPEG11 ZCPEG13 ZCPEN12 ZCPEF1212 1122 212-pole NC+NCSnap action32 3122 213-pole2NC+1NOSlow break1314131422 212-pole NC+NO - Snap actionConnector5-pinOption: pre-wired M12 connector,L = 2 m5-pin4-pinXZCP1164L2Connector4-pinXZCP1141L2131422 212-pole NC+NOSnap action131422 212-pole NC+NOSlow breakRef. metal body ZCD21 ZCD39 ZCD25 ZCD27 ZCD28 ZCD29 ZCD37 ZCD21M12 – – –Ref. plastic body ZCP21 ZCP39 ZCP25 ZCP27 ZCP28 ZCP29 ZCP37 – ZCP21M12 ZCT21P16 (1) ZCT25P16 (1)(1)ZCT Pg 11 cable gland versions:replace the suffix P16 by G11.Example:ZCT21P16 becomes ZCT21G11ZCT 1/2" NPT versions:replace the suffi x P16 byN12 (adaptor).Example:ZCT21P16 becomes ZCT21N121 Cable entry 1/2" NPT1 Cable entry Pg118910Other versions: please consult our Customer Care Centre.1/5


131422 213132212214 13<strong>OsiSense</strong> XCXCKMLimit switchesClassic - XCKM, XCKL, complete switchesISO entry(to EN 50262)2-pole contactNC+NOsnap action1131422 212-pole contactNC+NOslow break3-pole contact2NC+1NOsnap actionType XCKM metal, 3 cable entries, XCKL metal, 1 cable entry2345Type of operatorMetalend plungerSteelroller plungerRoller lever plunger, Thermoplastichorizontal actuation roller leverin 1 directionMechanical durability (millions of operating cycles) 20 20 20 15 10Actuation speed (in m/s) 0.5 0.5 1.5 1.5 0.5Product certificationCE - UL - CSA - CCC - GOST - C-TICK - BVDegree of protection conforming to IEC 60529 IP 665Rated operational characteristics AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)Cable entry (1) XCKM 3 tapped entries for ISO M20 x 1.5 cable gland (2 entries fi tted with blanking plugs)XCKL1 cable entry with cable glandFixing centres (mm) 41Body dimensions (mm) W x D x H XCKM / XCKL 64 x 30 x 64 / 52 x 30 x 72“Cat’s whisker”Complete switch XCKM2-pole NC+NO snap action XCKM110H29 XCKM102H29 XCKM121H29 XCKM115H29 XCKM106H292-pole NC+NO, break before make, slow break XCKM510H29 XCKM502H29 XCKM521H29 XCKM515H29 –Complete switch XCKL2-pole NC+NO snap action XCKL110 XCKL102 XCKL121 XCKL115 XCKL106(1) For Pg 13.5 cable entries delete the reference suffi x H29. Example: XCKM110H29 becomes XCKM110.Positive opening operation.6Classic - XCKM, XCKL,Customised assembly - Body/contact sub-assemblies78Type XCKM metal, 3 cable entriesType of contact9131422 21131422 2132 3122 21131432 3122 211314102-poleNC+NOsnap action2-poleNC+NOslow break3-pole2NC+1NOsnap action3-pole2NC+1NOslow breakReference of body with contact block ZCKM1H29 ZCKM5H29 ZCKMD39H29 ZCKMD37H29XCKL reference of body with contact block (2) ZCKL1 ZCKL5 – –Reference of contact block only XE2SP2151 XE2NP2151 XE3SP2141 XE3NP2141(2) For cable entry 1/2" NPT, add H7. Example: XCKL1 becomes XCKL1H71/6Other versions: please consult our Customer Care Centre.


Operating heads,complete or for customer assembly1Complete switch = Body/contact assembly + Head + LeverRotary or multi-directional headsmetal head withthermoplasticroller levermetal head withsteel roller leverwith variable length with Ø 6 mmthermoplastic thermoplastic rodroller lever (2) L = 200 mm (3)with thermoplasticroller lever (3)for actuation fromleft AND rightorleft OR rightwith “Cat’swhisker”with spring rod23Reference ZCKD15 ZCKD16 ZCKD41 ZCKD59 ZCKD31 ZCKD06 ZCKD084Plunger headswith metalend plungerwith metal endplunger andprotective bootwith steelroller plungerwith steel rollerplunger andprotective bootwith thermoplasticroller lever plunger,horizontal actuationin 1 directionwith steelroller lever plunger,horizontal actuationin 1 direction56Reference ZCKD10 ZCKD109 ZCKD02 ZCKD029 ZCKD21 ZCKD237Rotary heads and separate leversspring return,for actuation fromleft AND rightorleft OR rightlever withthermoplasticroller (2)lever withsteel roller (2)variable lengthlever withthermoplasticroller (2)variable lengthlever withsteel roller (2)rod, Ø 6 mmthermoplasticL = 200 mm (3)89Reference ZCKD05 ZCKY31 ZCKY33 ZCKY41 ZCKY43 ZCKY59(2) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.(3) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.10Other versions: please consult our Customer Care Centre.1/7


131422 213132212214 13<strong>OsiSense</strong> XCXCKJLimit switchesIndustrial - XCKJ, complete switchesISO entry(to EN 50262)2-pole contactNC+NOsnap action1131422 212-pole contactNC+NOslow break3-pole contact2NC+1NOsnap actionType XCKJ metal, fixed body, conforming to standard EN 500412345Type of operatorMetalend plungerSteelroller plungerThermoplasticroller leverSteelroller leverVariable lengththermoplasticroller leverPolyamide Ø 6mm rod leverL = 200 mmMechanical durability (millions of operating cycles) 30 25 30 30 30 30Actuation speed (in m/s) 0.5 1 1.5 1,5 1.5 1.5Product certificationCE - UL - CSA - CCC - GOST - C-TICK - BVDegree of protection conforming to IEC 60529 IP 667Rated operational characteristics AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)Cable entry (1)1 tapped entry for ISO M20 x 1.5 cable glandFixing centres (mm) 30 x 60Body dimensions (mm) W x D x H 40 x 44 x 77Complete switch M20 2-pole NC+NO snap action XCKJ161H29 XCKJ167H29 XCKJ10511H29 XCKJ10513H29 XCKJ10541H29 XCKJ10559H292-pole NC+NO break before make, slow break XCKJ561H29 XCKJ567H29 XCKJ50511H29 XCKJ50513H29 XCKJ50541H29 XCKJ50559H291/2" NPT 2-pole NC+NO snap action XCKJ161H7 XCKJ167H7 XCKJ10511H7 XCKJ10513H7 XCKJ10541H7 XCKJ10559H7M12 5P 2-pole NC+NO snap action XCKJ161D XCKJ167D XCKJ10511D XCKJ10513D XCKJ10541D XCKJ10559D(1) For Pg 13.5 cable entry delete the reference suffix H29. Example: XCKJ161H29 becomes XCKJ161.Positive opening operation.6Industrial - XCKJ,Customised assembly - Body/contact sub-assemblies78Type XCKJ metal, 1 cable entryType of contact9131422 21131422 2113141112232422 2132 3122 21131432 3122 211314102-poleNC+NOsnap action2-poleNC+NOslow break2 C/Osnap actionSimultaneous3-pole2NC+1NOsnap action3-pole2NC+1NOslow breakCable entry (1)1 tapped entry for ISO M20 x 1.5 cable glandReference of body with contact block M20 ZCKJ1H29 ZCKJ5H29 ZCKJ2H29 ZCKJD39H29 ZCKJD37H29Pg13 ZCKJ1 ZCKJ5 ZCKJ2 – –1/2" NPT ZCKJ1H7 ZCKJ5H7 ZCKJ2H7 – –M12 (5 pin) ZCKJ1D ZCKJ5D – – –Reference of contact block only XE2SP2151 XE2NP2151 – XE3SP2141 XE3NP21411/8Other versions: please consult our Customer Care Centre.


Operating heads,complete or for customer assembly1Plunger or multi-directional headswith reinforcedsteel rollerend plungerComplete switch= Body/contact assembly + Head + Leverwith metalend plungerwith thermoplasticroller lever plunger,1 direct. of actuationwith steelroller lever plunger,1 direct. of actuationwith steel rollerend plungerwith steelball bearingend plungerEnd steel rollerplunger withprotective boot2Référence ZCKE67 ZCKE61 ZCKE21 ZCKE23 ZCKE62 ZCKE66 ZCKE6293with metalside plungerSide steel rollerplunger,horizontalSide steel rollerplunger,verticalwith spring rodwith “Cat’s whisker”45Reference ZCKE63 ZCKE64 ZCKE65 ZCKE08 ZCKE066Separate rotary heads and leversspring returnfor actuationfromleft AND rightorleft OR rightlever withthermoplasticroller (2)lever withsteel roller (2)variable lengthlever withthermoplasticroller (2)variable lengthlever withsteel roller (2)rod, Ø 6 mmthermoplasticL = 200 mm (2)square rod lever,steel, U 3 mmL = 125 mm (2)round rod lever, spring leversteel, Ø 3 mm withL = 125 mm (2) thermoplasticend (3)spring-metalrod lever(3)78Reference ZCKE05 ZCKY11 ZCKY13 ZCKY41 ZCKY43 ZCKY59 ZCKY51 ZCKY53 ZCKY81 ZCKY91stay putfor actuation fromleft AND rightforked arm leverwith thermoplasticrollers, 1 track (2)forked arm leverwith thermoplasticrollers, 2 track (2)910Reference ZCKE09 ZCKY71 ZCKY61(2) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.(3) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.Other versions: please consult our Customer Care Centre.1/9


31321314212222 2114 13<strong>OsiSense</strong> XCLimit switchesClassic - XCKS, complete switches1XCKS131422 212-pole contactNC+NOsnap action2-pole contactNC+NOslow break3-pole2NC+1NOsnap actionXCKMR1112XCR131422 2122 211112131422 2122 212 x 2-polecontactsNC+NCstaggered,slow break2 x 2-polecontacts,snap actionISO entry(to EN 50262)Type XCKS plastic, double insulated, conforming to standard EN 50041234567Type of operatorMetalSteelThermoplastic Variable length Rubber Polyamide Ø 6 mmend plunger roller plunger roller lever thermoplasticroller leverroller leverØ 50 mmrod leverL = 200 mmMechanical durability (millions of operating cycles) 25 15 20 20 20 20Actuation speed (in m/s) 0.5 0.5 1.5 1.5 1 1Product certificationCE - UL - CSA - CCC - GOST - C-TICKDegree of protection conforming to IEC 60529 IP 653Rated operational characteristics AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)Cable entry (1)1 tapped entry for ISO M20 x 1.5 cable glandFixing centres (mm) 30 x 60Body dimensions (mm) W x D x H 40 x 36 x 72.5Complete switch 2-pole NC+NO snap action XCKS101H29 XCKS102H29 XCKS131H29 XCKS141H29 XCKS139H29 XCKS159H292-pole NC+NO break before make, slow break XCKS501H29 XCKS502H29 XCKS531H29 XCKS541H29 XCKS539H29 XCKS559H29Body 2-pole NC+NO snap action ZCKS1H29 ZCKS1H29 ZCKS1H29 ZCKS1H29 ZCKS1H29 ZCKS1H292-pole NC+NO break before make, slow break ZCKS5H29 ZCKS5H29 ZCKS5H29 ZCKS5H29 ZCKS5H29 ZCKS5H293-pole 2NC+1NO snap action ZCKSD39H29 ZCKSD39H29 ZCKSD39H29 ZCKSD39H29 ZCKSD39H29 ZCKSD39H29Associated head (including operator) ZCKD01 ZCKD02 ZCKD31 ZCKD41 ZCKD39 ZCKD59Operating lever for rotary head – – ZCKY31 ZCKY41 ZCKY39 ZCKY59Complete switch Snap-action 2-pole 2X (1 NC + 1 NO) contactBoth contacts act in each direction of actuation – – – – – –1 contact operates in each direction – – – – – –Complete switch 2 C/O staggered snap action contacts – – – – – –Positive opening operation.2 (NC + NO) staggered, slow break contacts – – – – – –(1) For Pg 13.5 cable entry delete the reference suffix H29. Example: XCKJ161H29 becomes XCKJ161.For severe applications - XC2J,Customised assembly - Body/contact sub-assemblies8Type XC2J metal, fixed body, 1 cable entry incorporating cable gland9Type of contact14 1312 11131412 11232422 2110Single-pole1 C/O contactsnap actionReference of body with contact block ZC2JC1 ZC2JC2Reference of contact block only XCKZ01 XESP1021Double-pole2 C/O simultaneous contactssnap action1/10Other versions: please consult our Customer Care Centre.


Severe duty for hoisting and materials handling applicationsXCKMR and XCR, complete switchesISO entry(to EN 50262)1Types XCKMR and XCR “Application - hoisting, materials handling, conveying”Square rod levers Square rod lever Large roller rod lever Square rod levers Conveyor belt shift monitoring switches6 mm, “crossed” 6 mm Ø 50 mm 6 mm, “crossed” or “T” Galvanised steeloperating leverStainless steeloperating lever2 10 10 10 0.3 0.31.5 1.5 1.5 1.5 1.5 1.5CE - UL - CSA - GOST CE - CSA - CCC - GOSTIP 545 IP 665AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)3 x ISO M20 x 1.5 entries 1 tapped entry for n° 13 cable gland (for ISO M20 x 1.5, adaptor DE9RA1620 must be ordered separately)61.5 85 x 75 105 x 70118 x 59 x 77 85 x 75 x 95 85 x 87 x 146– – – – – –– – – – – –– – – – – –– – – – – –– – – – – –– – – – – –– – – – – –– XCRA11(2) XCRA15 XCRE18(2) – –– XCRB11(2) – XCRF17(3) – –– XCRT115 XCRT315 (4)XCKMR54D1H29 (2) – – – – –(2) Steel rods, L = 200 mm (3) Steel “T” rods, L = 200 mm, W = 300 mm. (4) Polyester enclosureOperating heads, complete or for customer assemblyPlunger headswith metal end plungerwith steel roller end plunger234567Reference ZC2JE61 ZC2JE62Rotary heads and separate leversspring returnfor actuation fromleft AND rightspring returnfor actuation fromleft OR rightvariable length leverwith thermoplasticroller (1)rigid rod3 mm, steelL = 125 mm (1)lever withthermoplastic roller(1)lever withsteel roller (1)spring lever(1)spring-rod lever89Reference ZC2JE01 ZC2JE05 ZC2JY31 ZC2JY51 ZC2JY11 ZC2JY13 ZC2JY81 ZC2JY91ry head(1) Adjustable throughout 360°. s and separate levers10Other versions: please consult our Customer Care Centre.1/11


<strong>OsiSense</strong> XMSensors for pressure controlElectronic sensors XMLGElectrical connection by M12 connector12345Pressure range(bar) (1)Fluids controlledAmbient air temperature - 15…+ 85°CDegree of protectionIP 66 and IP 67(conforming to IEC 60529)-1…0 0…1 0…6 0…10 0…16 0…25 0…100 0…250 0…400Hydraulic oils, air, fresh water, sea water, corrosive fluids from -15…+125°CProduct certificationCE - UL - CSA - GOSTVoltage limits12…24 V DC, 8…33 V DC for 4…20 mA, 11.4…33V DC for 0…10 VDimensions (mm) Ø x LØ 22.8 x 70 (not including connector)Fluid connection (2)G 1/4" A (male)Electrical connection (3)M12 connectorType of output (4)4…20 mA, 2-wire technique, 0…10V, 3-wire techniqueAnalogue output 4…20 mA XMLGM01D21 XMLG001D21 XMLG006D21 XMLG010D21 XMLG016D21 XMLG025D21 XMLG100D21 XMLG250D21 XMLG400D210…10 V XMLGM01D71 XMLG001D71 XMLG006D71 XMLG010D71 XMLG016D71 XMLG025D71 XMLG100D71 XMLG250D71 XMLG400D71Available in bulk packs for selling in lots, please consult us.The XMLG range also includes pressure switches, please consult us.Electronic sensors XMLEElectrical connection by DIN 43650 connector6789Setting range(bar) (1)Fluids controlled-1…0 0…1 0…10 0…25 0…100 0…250 0…600Hydraulic oils, air, fresh water, sea water, corrosive fluids from -15…+80°CAmbient air temperature - 15…+ 80°CDegree of protection (conforming to IEC 60529) IP 65Product certificationCE - UL - CSA - GOSTVoltage limits24 V DC, 11…33 V DCDimensions (mm) Ø x LØ 40 x 90 (not including connector)Fluid connection (2)G 1/4" A (male)Electrical connection (3)DIN 43650 connectorType of output (4) Transmitter 4…20 mA, 2-wire techniquePressure switchPNP or NPN, normally closed (NC)Analogue output 4…20 mA XMLEM01U1C21 XMLE001U1C21 XMLE010U1C21 XMLE025U1C21 XMLE100U1C21 XMLE250U1C21 XMLE600U1C21NPN output XMLEM01U1C31 XMLE001U1C31 XMLE010U1C31 XMLE025U1C31 XMLE100U1C31 XMLE250U1C31 XMLE600U1C31PNP output XMLEM01U1C41 XMLE001U1C41 XMLE010U1C14 XMLE025U1C41 XMLE100U1C41 XMLE250U1C41 XMLE600U1C41(1) Other sizes, please consult us. (3) Other types of connection, please consult us.(2) Other fluid connections, please consult us. (4) Other types of output; 0…5 V, 0…10 V, etc., please consult us.Suitable female plug-in connectorsPre-wired connectors, L = 5 m (without LED)Other connectors10elbowed straight Screw terminal DIN 43650AM12 XZCP1241L5 XZCP1141L5 XZCC12FCM40B XZCC43FCP40B1/12Other versions: please consult our Customer Care Centre.


Electronic sensors XMLF1Setting range of lower limit (PB):(bar) of upper limit (PH):Fluids controlledvacuum switchespressure switches-0.08…-1 0.08...1 0.2…2.5 0.8…10 3.2...40Hydraulic oils, air, fresh water, sea water, corrosive fluids from -15…+80°CAmbient air temperature - 25…+ 80°CDegree of protection (conforming to IEC 60529) IP 67Product certificationCE - UL - CSA - VIT-SEPRO - GOSTVoltage limits (V)24 V DC (17…33 V DC)Dimensions (mm) H x W x D 113 x 46 x 58Fluid connection G 1/4" (female) (1)Electrical connection M12 connector (2)Configurable with digital display, connection by M12 connector (3)Universal sensors, 4...20 mA XMLFM01D2025 XMLF001D2025 XMLF002D2025 XMLF010D2025 XMLF040D2025solid-state output, 200 mA (4) 0...10 V XMLFM01D2125 XMLF001D2125 XMLF002D2125 XMLF010D2125 XMLF040D2125Dual stage pressure switches, solid-state output, 200 mA XMLFM01D2035 XMLF001D2035 XMLF002D2035 XMLF010D2035 XMLF040D2035Analogue sensors 4...20 mA XMLFM01D2015 XMLF001D2015 XMLF002D2015 XMLF010D2015 XMLF040D20150...10 V XMLFM01D2115 XMLF001D2115 XMLF002D2115 XMLF010D2115 XMLF040D2115Possible differential (bar) Min. at low setting 0.03 0.03 0.08 0.3 1.2(pressure switches) Min. at high setting 0.03 0.03 0.08 0.3 1.2Max. at high setting 0.95 0.95 2.38 9.5 3823456Setting range of upper limit (PH): pressure switches(bar)8…100 12.8...160 20...250 32...400 48...600Fluids controlledHydraulic oils, air, fresh water, sea water, corrosive fluids from -15…+80°CAmbient air temperature - 25…+ 80°CDegree of protection (conforming to IEC 60529) IP 67Product certificationCE - UL - CSA - VIT-SEPRO - GOSTVoltage limits (V)24 V DC (17…33 V DC)Dimensions (mm) H x W x D 113 x 46 x 58Fluid connection G 1/4" (female) (1)Electrical connection M12 connector (2)Configurable with digital display, connection by M12 connector (3)Universal sensors, 4...20 mA XMLF100D2025 XMLF160D2025 XMLF250D2025 XMLF400D2025 XMLF600D2025solid-state output, 200 mA (4) 0...10 V XMLF100D2125 XMLF160D2125 XMLF250D2125 XMLF400D2125 XMLF600D2125Dual stage pressure switches, solid-state output, 200 mA XMLF100D2035 XMLF160D2035 XMLF250D2035 XMLF400D2035 XMLF600D2035Analogue sensors 4...20 mA XMLF100D2015 XMLF160D2015 XMLF250D2015 XMLF400D2015 XMLF600D20150...10 V XMLF100D2115 XMLF160D2115 XMLF250D2115 XMLF400D2115 XMLF600D2115Possible differential (bar) Min. at low setting 3 4.8 7.5 12 18(pressure switches) Min. at high setting 3 4.8 7.5 12 18Max. at high setting 95 152 237.5 380 570(1) Available with other fluid connections: 1/4" NPT female and SAE 7/16-20 UNF.(2) For M12 connection accessories, see previous page.(3) AC 120 V version with 2.5 A relay output and SAE 7/8-16 UN connector also available.(4) Programmable NPN or PNP and NO or NC.78910Other versions: please consult our Customer Care Centre.1/13


<strong>OsiSense</strong> XMISO entry(to EN 50262)Sensors for pressure controlElectromechanical pressure and vacuum switchesXMLA and B1131412 111 C/Osingle-polecontact,snap actionSize (bar) -1 5 1 2.52345Environmental characteristics Ambient air temperature (°C): - 25…+ 70 Degree of protection (conforming to IEC 60529): IP 66Rated operational characteristics AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)Product certificationCE - UL - CSA - CCC - BV - LROS - RINA - GL - DNV - VIT-SEPRO - GOSTFluid connectionG 1/4" (female) (other connections possible, please consult us)Electrical connectionScrew terminals (1), tapped entry for ISO M20 x 1.5 cable gland - For n° 13 (DIN Pg 13.5) cable glandFluids controlledHydraulic oils, fresh water,sea water, air up to 70°CHydraulic oils,air up to 160°CHydraulic oils, fresh water,sea water, air up to 70°CType XMLA - fixed differential, single threshold detectionSetting range (bar) of upper limit (PH): pressure switches -0.28…-1 (4) – 0.03…1 0.15…2.5Dimensions (mm) H x W x D 113 x 35 x 75 113 x 35 x 75 162 x 110 x 110 158 x 55 x 77.5With setting scale 1 C/O single-pole, snap action contact XMLAM01V2S12 – XMLA001R2S12 XMLA002A2S12Natural differential (bar) at low setting 0.24 (2) – 0.02 0.13subtract from PH to give PB at high setting 0.24 (2) – 0.04 0.13Type XMLB - adjustable differential, regulation between 2 thresholdsSetting range (bar) of upper limit (PH): pressure switches -0.14...-1 (4) -0.5...5 0.05...1 0.3...2.5With setting scale 1 C/O single-pole, snap action contact XMLBM02V2S12 XMLBM05A2S12 XMLB001R2S12 XMLB002A2S12Possible differential (bar) Min. at low setting 0.13 (3) 0.5 0.04 0.16subtract from PH to give PB Min. at high setting 0.13 (3) 0.5 0.06 0.21Max. at high setting 0.8 (3) 6 0.75 1.7567XMLC14 1312 11XMLD14 1312 1124 23 24 2322 2122 212 C/O single-polecontacts,simultaneoussnap action2 C/O single-polecontacts,snap action(1 per stage)ISO entry(to EN 50262)XMLC and D8910Fluids controlledHydraulic oils, fresh water,Hydraulic oils,Hydraulic oils, fresh water,sea water, air up to 70°Cair up to 160°C sea water, air up to 160°CType XMLC - adjustable differential, regulation between 2 thresholdsSetting range (bar) of upper limit (PH): pressure switches -0.14...-1 (4) -0.55...5 0.05...1 0.3...2.5Dimensions (mm) H x W x D 113 x 46 x 85 113 x 46 x 85 175 x 110 x 110 158 x 55 x 90With setting scale 2 C/O single-pole, snap action contacts XMLCM02V2S12 XMLCM05A2S12 XMLC001R2S12 XMLC002B2S12Possible differential (bar) Min. at low setting 0.13 (4) 0.45 0.03 0.13subtract from PH to give PB Min. at high setting 0.14 (4) 0.45 0.04 0.17Max. at high setting 0.8 (4) 6 0.8 2Type XMLD - fixed differential, dual stage, for detection at each thresholdSetting range2 nd stage switching point (PB2) -0.12...-1 (4) – 0.12...1 0.34...2.5(bar)1 st stage switching point (PB1) -0.10...-0.98 – 0.04...0.92 0.2...2.36Spread between 2 stages (PB2 – PB1) -0.02...-0.88 – 0.08...0.73 0.14...1.5Without setting scale 2 C/O single-pole, snap action contacts (1 per stage) XMLDM02V1S12 – XMLD001R1S12 XMLD002B1S12Natural differential (bar) at low setting 0.1 (2) – 0.03 0.14subtract from PH 1/2 to give PB 1/2 at high setting 0.1 (2) – 0.07 0.191/14Other versions: please consult our Customer Care Centre.


14 10 20 35 70 160 300 500conforming to IEC 947-5-1 Appendix A, EN 60 947-5-12tapped entry, replace the last number of the reference (2) by 1 (example: XMLA010A2S12 becomes XMLA010A2S11)Hydraulic oils, fresh water,sea water, air up to 70°CHydraulic oils up to 160°C30.4…4 0.6…10 1…20 1.5…35 5…70 10…160 20…300 30…500113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75XMLA004A2S12 XMLA010A2S12 XMLA020A2S12 XMLA035A2S12 XMLA070D2S12 XMLA160D2S12 XMLA300D2S12 XMLA500D2S120.35 0.5 0.4 1.25 3 5.5 16.5 200.35 0.5 1 1.25 7.5 18 35 4540.25...4 0.7...10 1.3...20 3.5...35 7...70 10...160 22...300 30...500XMLB004A2S12 XMLB010A2S12 XMLB020A2S12 XMLB035A2S12 XMLB070D2S12 XMLB160D2S12 XMLB300D2S12 XMLB500D2S120.02 0.57 1 1.7 4.7 9.3 19.4 230.25 0.85 1.6 2.55 8.8 20.8 37 52.62.4 7.5 11 20 50 100 200 300(1) For electrical connection by DIN 43650A connector (IP 65), replace the suffix “S12” in the reference by “C11”. Example: XMLB010A2S12 becomes XMLB010A2C11.(2) For vacuum switch: natural differential to be added to PB to give PH.(3) For vacuum switch: possible differential to be added to PB to give PH.(4) Setting range (bar) of lower limit (PB): vacuum switch.567Hydraulic oils, fresh water,Hydraulic oils up to 160°Csea water, air up to 160°C0.3...4 0.7...10 1.3...20 3.5...35 7...70 12...160 22...300 30...500113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85XMLC004B2S12 XMLC010B2S12 XMLC020B2S12 XMLC035B2S12 XMLC070D2S12 XMLC160D2S12 XMLC300D2S12 XMLC500D2S120.15 0.45 0.7 1 4.5 9 16 190.17 0.7 1 1.5 8.9 21 35 522.5 8 11 22 60 110 240 340890.40...4 1.2...10 2.14...20 4.4...35 9.4...70 16.5...160 36...300 41...5000.19...3.79 0.52...9.32 0.9...18.76 1.9...32.5 6.6...67.2 10.5...154 25...289 25...4840.21...2.18 0.68...5.8 1.24...9.55 2.5...20.4 2.8...46 6...83 11...189 16...244XMLD004B1S12 XMLD010B1S12 XMLD020B1S12 XMLD035B1S12 XMLD070D1S12 XMLD160D1S12 XMLD300D1S12 XMLD500D1S120.15 0.45 0.7 1.5 5 8.8 17 210.19 0.6 1.3 2.6 9.5 20 42 6510Other versions: please consult our Customer Care Centre.1/15


<strong>OsiSense</strong> XMSensors for pressure controlElectromechanical pressure switches XMX, XMA1131422 211 C/Osingle-polecontact,snap actionSetting range of upper limit (PH) (bar) 1…6 1.3…12 3.5…25234Fluids controlledAir, water (fresh water, sea water) from 0…+70°CAmbient air temperature - 25…+ 70°CDegree of protection (conforming to IEC 60529) IP 54Rated operational characteristics AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)Product certificationCE - UL - CSA - CCCDimensions (mm) H x W x D 106 x 57 x 98 126 x 57 x 98Fluid connection1/4" BSP femaleElectrical connectionScrew terminals, 2 tapped entries for n° 13 (DIN Pg 13.5) cable glandType XMX with internal setting screwWithout setting scale, screw terminal connections1 C/O single-pole, snap action contact XMXA06L2135 XMXA12L2135 XMXA25L2135Possible differential (bar) Min. at low setting 0.8 1 3.4subtract from PH to give PB Min. at high setting 1.2 1.7 4.5Max. at high setting 4.2 8.4 2056131422 211 C/Osingle-polecontact,snap actionSetting range of upper limit (PH) (bar) 1…6 1.3…12 3.5…25789Fluids controlledAir, water (fresh water, sea water) from 0…+70°CAmbient air temperature - 25…+ 70°CDegree of protection (conforming to IEC 60529) IP 54Rated operational characteristics AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)Product certificationCE - UL - CSA - CCCDimensions (mm) H x W x D 113 x 57 x 98 133 x 57 x 98Fluid connection1/4" BSP femaleElectrical connectionScrew terminals, tapped entry for n° 13 (DIN Pg 13.5) cable glandType XMA with external setting screw (transparent cover)Without setting scale, screw terminal connections1 C/O single-pole, snap action contact XMAV06L2135 XMAV12L2135 XMAV25L2135Possible differential (bar) Min. at low setting 0.8 1 3.4subtract from PH to give PB Min. at high setting 1.2 1.7 4.5Max. at high setting 4.2 8.4 20101/16Other versions: please consult our Customer Care Centre.


Electromechanical pressure switchesfor power circuits, adjustable differentialfor regulation between 2 thresholds12342 NC 2-polecontact, snap action1Degree of protection IP 20 IP 65Size (bar) 4.6 7 10.5 4.6 7 10.5Setting range of upper limit (PH) (bar) 1.4…4.6 2.8…7 5.6…10.5 1.4…4.6 2.8…7 5.6…10.5Fluids controlledWater (fresh water, sea water) from 0…+55°CElectrical connection Screw terminals, 2 cable entries with grommet Screw terminals, 2 tapped entriesfor n° 13 (DIN Pg 13.5) cable glandProduct certificationCEAmbient air temperature For operation: 0…+ 50°C. For storage: - 30…+ 80°CRated operational characteristicsIe = 10 A, Ue = 250 V ACPower rating 110 V AC 2-pole, single-phase 0.75 kW (1 HP) 0.75 kW (1 HP)of controlled AC 2-pole, 3-phase 1.1 kW (1.5 HP) 1.1 kW (1.5 HP)motors 230 / 400 V AC 2-pole, single-phase 1.5 kW (2 HP) 1.5 kW (2 HP)AC 2-pole, 3-phase 2.2 kW (3 HP) 2.2 kW (3 HP)Dimensions (mm) H x W x D 96/105 x 72 x 102 94 x 72 x 102 115 x 72 x 106 115 x 72 x 106Fluid connection G 1/4 (BSP female) FSG2 FYG22 FYG32 FSG2NE FYG22NE FYG32NER 1/4 (BSP male) FSG9 FYG29 FYG39 – – –G 3/8 (BSP female) rotating nut – – – FSG2NEG – –Possible differential (bar) At low setting 1 min. - 2.1 max. 1.2 min. - 2.3 max. 1.9 min. - 3 max. 1 min. - 2.1 max. 1.2 min. - 2.3 max. 1.9 min. - 3 max.subtract from PH to give PB At middle setting 1.1 min. - 2.2 max. 1.4 min. - 2.5 max. 2.1 min. - 3.2 max. 1.1 min. - 2.2 max. 1.4 min. - 2.5 max. 2.1 min. - 3.2 max.At high setting1.2 min. - 2.3 max. 1.6 min. - 2.7 max. 2.3 min. - 3.4 max. 1.2 min. - 2.3 max. 1.6 min. - 2.7 max. 2.3 min. - 3.4 max.23451231352 NC 2-pole contact,snap action4243 NC 3-pole contact,snap action66Size (bar) 6 12 25Setting range of upper limit (PH) (bar) 1…6 1.3.…12 3.5…25Fluids controlledAir, water (fresh water, sea water) from 0…+70°CAmbient air temperature For operation: - 25…+ 70°C. For storage: - 40…+ 70°CDecompression valve / ONOff knob without with without with withoutFluid connection G 1/4 (BSP female) 4 x G 1/4 (BSP female) G 1/4 (BSP female) 4 x G 1/4 (BSP female) G 1/4 (BSP female)Electrical connectionScrew terminals, 2 tapped entries for n° 13 (DIN Pg 13.5) cable glandDegree of protection IP 54 IP 54 IP 54Product certificationCE - CCCRated insulation voltageUi = 500 VElectrical Power 1.5 kW 400 V AC 3-phase: 1 000 000 operating cyclesdurability230 V AC 3-phase: 600 000 operating cycles2.2 kW 400 V AC 3-phase: 700 000 operating cycles3 kW 400 V AC 3-phase: 500 000 operating cyclesDimensions (mm) H x W x D 106 x 57 x 97.5 138 x 57 x 97.5 106 x 57 x 97.5 138 x 57 x 97.5 126 x 57 x 97.5Type of contacts 2 NC 2-pole, snap action contact XMPA06B2131 XMPE06B2431 XMPA12B2131 XMPE12B2431 XMPA25B21313 NC 3-pole, snap action contact XMPA06C2131 XMPE06C2431 XMPA12C2131 XMPE12C2431 XMPA25C2131Possible differential (bar) Min. at low setting 0.8 0.8 1 1 3.4subtract from PH to give PB Min. at high setting 1.2 1.2 1.7 1.7 4.5Max. at high setting 4.2 4.2 8.4 8.4 2078910Other versions: please consult our Customer Care Centre.1/17


<strong>OsiSense</strong> <strong>XS</strong>Inductive proximity sensorsCylindrical metal1Non flushmountableFlushmountable23456789Flush standard and increased rangeM8M12Nominal sensing distance Sn 1.5 mm 2.5 mm 2 mm 4 mmUsable sensing distance S (mm) flush mountable / non flush mountable 0…1.2 0…2 0…1.6 0…3.2Temperature range (°C) - 25…+ 70Product certificationCE - UL - CSA - CCC (in progress) - C-TICKDegree of protection (conforming to IEC 60529) IP 67 pre-cabled: IP 69K conforming to DIN 40050, IP 68Sensors for DC applicationsOutput function NO A A A ANC B B B BDimensions (mm) Ø x L Cable / Connector M8 x 33 / M8 x 42 M12 x 35 / M12 x 503-wire PNP Cable (2 m) <strong>XS</strong>508B1PAL2 <strong>XS</strong>108B3PAL2 <strong>XS</strong>512B1PAL2 <strong>XS</strong>112B3PAL2Connector M8 / M12 <strong>XS</strong>508B1PAM8 <strong>XS</strong>108B3PAM8 <strong>XS</strong>512B1PAM12 <strong>XS</strong>112B3PAM12NPN Cable (2m) <strong>XS</strong>508B1NAL2 <strong>XS</strong>108B3NAL2 <strong>XS</strong>512B1NAL2 <strong>XS</strong>112B3NAL2Connector M8 / M12 <strong>XS</strong>508B1NAM8 <strong>XS</strong>108B3NAM8 <strong>XS</strong>512B1NAM12 <strong>XS</strong>112B3NAM122-wire non Cable (2 m) <strong>XS</strong>508BSCAL2 <strong>XS</strong>608B3CAL2 <strong>XS</strong>512BSDAL2 <strong>XS</strong>612B3DAL2polarised (1) Connecteur M12 <strong>XS</strong>508BSCAL01M12 <strong>XS</strong>608B3CAL01M12 <strong>XS</strong>512BSDAM12 <strong>XS</strong>612B3DAM12Supply voltage limits, min./max. (V) including ripple 10…36 10…36 10…36 10…36Switching capacity, max. (mA) 3-wire / 2-wire 200 / 100 200 / 100 200 / 100 200 / 100Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗ g / ⊗Residual current, open state (mA) ≤ 0.5 ≤ 0.5 ≤ 0.5 ≤ 0.5Voltage drop, closed state (V) at I nominal 3-wire / 2-wire ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4Switching frequency (Hz) 3-wire / 2-wire 5000 / 4000 2500 / 3000 5000 / 4000 2500 / 2000Dimensions (mm) Ø x L Cable / connector M8 x 51 / M8 x 62 M12 x 53 / M12 x 623-wire PNP Cable (2 m) <strong>XS</strong>508BLPAL2 <strong>XS</strong>608B1PAL2 <strong>XS</strong>512BLPAL2 <strong>XS</strong>612B1PAL2Connector M12 <strong>XS</strong>508BLPAM12 <strong>XS</strong>608B1PAM12 <strong>XS</strong>512BLPAM12 <strong>XS</strong>612B1PAM12NPN Cable (2 m) <strong>XS</strong>508BLNAL2 <strong>XS</strong>608B1NAL2 <strong>XS</strong>512BLNAL2 <strong>XS</strong>612B1NAL2Connector M12 <strong>XS</strong>508BLNAM12 <strong>XS</strong>608B1NAM12 <strong>XS</strong>512BLNAM12 <strong>XS</strong>612B1NAM122-wire non Cable (2 m) <strong>XS</strong>508B1DAL2 <strong>XS</strong>608B1DAL2 <strong>XS</strong>512B1DAL2 <strong>XS</strong>612B1DAL2polarised Connector M12 <strong>XS</strong>508B1DAM12 <strong>XS</strong>608B1DAM12 <strong>XS</strong>512B1DAM12 <strong>XS</strong>612B1DAM12Supply voltage limits, min./max. (V) including ripple 10…58 10…58 10…58 10…58Switching capacity, max. (mA) 3-wire / 2-wire 200 / 100 200 / 100 200 / 100 200 / 100Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗ g / ⊗Residual current, open state (mA) 2-wire ≤ 0.5 ≤ 0.5 ≤ 0.5 ≤ 0.5Voltage drop, closed state (V) at I nominal 3-wire / 2-wire ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4Switching frequency (Hz) 3-wire / 2-wire 5000 / 4000 2500 / 3000 5000 / 4000 2500 / 2000Multi-current/multi-voltage sensors for AC/DC applicationsDimensions (mm) Ø x L Cable / connector – – M12 x 53 / M12 x 622-wire Cable (2 m) – – <strong>XS</strong>512B1MAL2 <strong>XS</strong>612B1MAL2Connector 1/2"-20 UNF – – <strong>XS</strong>512B1MAU20 <strong>XS</strong>612B1MAU20Supply voltage limits, min./max. (V) including ripple – – 20…264 20…264Switching capacity, max. (mA) – – 200 200LED output state indicator (⊗) – – ⊗ ⊗Residual current, open state (mA) – – ≤ 0,8 ≤ 0,8Voltage drop, closed state (V) at I nominal – – ≤ 5.5 ≤ 5.5Switching frequency (Hz) – – 25 AC / 1000 DC 25 AC / 1000 DC(1) polarised for M8 short10AccessoriesFixing for cylindrical sensorsFixing clamp with indexing pinfor cylindrical sensorsSuitable female plug-in connectorsM8 Straight ElbowedM8 <strong>XS</strong>ZB108 Metal ring XZCC8FDM30S XZCC8FCM30SM12 <strong>XS</strong>ZB112 M12 (4 pin)M18 <strong>XS</strong>ZB118 Metal ring XZCC12FDM40B XZCC12FCM40BM30 <strong>XS</strong>ZB130 Plastic ring XZCC12FDP40B XZCC12FCP40B1/18Other versions: please consult our Customer Care Centre.


1Non flush increased rangeM18 M30 M12 M18 M305 mm 8 mm 10 mm 15 mm 7 mm 12 mm 22 mm0…4 0…6.4 0…8 0…12 0…5.6 0…9.6 0…17.6- 25…+ 70 - 25…+ 70CE - UL - CSA - CCC (in progress) - C-TICKCE - UL - CSA - CCC (in progress) - C-TICK(with connector: IP 67) pre-cabled: IP 69K conforming to DIN 40050, IP 68 (with connector: IP 67)A A A A A A AB B B B B B BM18 x 39 / M18 x 50 M30 x 43 / M30 x 55 –<strong>XS</strong>518B1P AL2 <strong>XS</strong>118B3P AL2 <strong>XS</strong>530B1P AL2 <strong>XS</strong>130B3P AL2 –<strong>XS</strong>518B1P AM12 <strong>XS</strong>118B3P AM12 <strong>XS</strong>530B1P AM12 <strong>XS</strong>130B3P AM12 –<strong>XS</strong>518B1N AL2 <strong>XS</strong>118B3N AL2 <strong>XS</strong>530B1N AL2 <strong>XS</strong>130B3N AL2 –<strong>XS</strong>518B1N AM12 <strong>XS</strong>118B3N AM12 <strong>XS</strong>530B1N AM12 <strong>XS</strong>130B3N AM12 –<strong>XS</strong>518BSD AL2 <strong>XS</strong>618B3D AL2 <strong>XS</strong>530BSD AL2 <strong>XS</strong>630B3D AL2 –<strong>XS</strong>518BSD AM12 <strong>XS</strong>618B3D AM12 <strong>XS</strong>530BSD AM12 <strong>XS</strong>630B3D AM12 –10…36 10…36 10…36 10…36 –200 / 100 200 / 100 200 / 100 200 / 100 –g / ⊗ g / ⊗ g / ⊗ g / ⊗ –≤ 0.5 ≤ 0.5 ≤ 0.5 ≤ 0.5 –≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 –2000 / 3000 1000 / 1000 1000 / 2000 500 / 500 –M18 x 62 / M18 x 74 M30 x 62 M12 x 55 / M12 x 65 M18 x 62 / M18 x 74 M30 x 62 / M30 x 74<strong>XS</strong>518BLP AL2 <strong>XS</strong>618B1P AL2 <strong>XS</strong>530BLP AL2 <strong>XS</strong>630B1P AL2 <strong>XS</strong>612B4PAL2 <strong>XS</strong>618B4PAL2 <strong>XS</strong>630B4PAL2<strong>XS</strong>518BLP AM12 <strong>XS</strong>618B1P AM12 <strong>XS</strong>530BLP AM12 <strong>XS</strong>630B1P AM12 <strong>XS</strong>612B4PAM12 <strong>XS</strong>618B4PAM12 <strong>XS</strong>630B4PAM12<strong>XS</strong>518BLN AL2 <strong>XS</strong>618B1N AL2 <strong>XS</strong>530BLN AL2 <strong>XS</strong>630B1N AL2 <strong>XS</strong>612B4NAL2 <strong>XS</strong>618B4NAL2 <strong>XS</strong>630B4NAL2<strong>XS</strong>518BLN AM12 <strong>XS</strong>618B1N AM12 <strong>XS</strong>530BLN AM12 <strong>XS</strong>630B1N AM12 <strong>XS</strong>612B4NAM12 <strong>XS</strong>618B4NAM12 <strong>XS</strong>630B4NAM12<strong>XS</strong>518B1D AL2 <strong>XS</strong>618B1D AL2 <strong>XS</strong>530B1D AL2 <strong>XS</strong>630B1D AL2 – – –<strong>XS</strong>518B1D AM12 <strong>XS</strong>618B1D AM12 <strong>XS</strong>530B1D AM12 <strong>XS</strong>630B1D AM12 – – –10…58 10…58 10…58 10…58 10…58 10…58 10…58200 / 100 200 / 100 200 / 100 200 / 100 200 / – 200 / – 200 / –g / ⊗ g / ⊗ g / ⊗ g / ⊗ g / ⊗ g / ⊗ g / ⊗≤ 0.5 ≤ 0.5 ≤ 0.5 ≤ 0.5 – – –≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / – ≤ 2 / – ≤ 2 / –2000 / 3000 1000 / 1000 1000 / 2000 500 / 500 2500 / – 1000 / – 500 / –M18 x 62 / M18 x 73 M30 x 62 / M30 x 73 – M18 x 60 / M18 x 72 M30 x 63 / M30 x 74<strong>XS</strong>518B1M AL2 <strong>XS</strong>618B1M AL2 <strong>XS</strong>530B1M AL2 <strong>XS</strong>630B1M AL2 – <strong>XS</strong>618B4MAL2 <strong>XS</strong>630B4MAL2<strong>XS</strong>518B1M AU20 <strong>XS</strong>618B1M AU20 <strong>XS</strong>530B1M AU20 <strong>XS</strong>630B1M AU20 – <strong>XS</strong>618B4MAU20 <strong>XS</strong>630B4MAU2020…264 20…264 20…264 20…264 – 20…264 20…264300 AC / 200 DC 300 AC / 200 DC 300 AC / 200 DC 300 AC / 200 DC – 300 AC / 200 DC 300 AC / 200 DC⊗ ⊗ ⊗ ⊗ – ⊗ ⊗≤ 0.8 ≤ 0.8 ≤ 0.8 ≤ 0.8 – ≤ 0.8 ≤ 0.8≤ 5.5 ≤ 5.5 ≤ 5.5 ≤ 5.5 – ≤ 5.5 ≤ 5.525 AC / 1000 DC 25 AC / 1000 DC 25 AC / 500 DC 25 AC / 500 DC – 25 AC / 1000 DC 25 AC / 300 DC23456789Pre-wired connectors M8 (3 pin) 1/2" M12 (4 pin)Straight Elbowed Straight Elbowed Straight Elbowed Elbowed PNP LED2 m XZCP0566L2 XZCP0666L2 2 m XZCP1865L2 XZCP1965L2 2 m XZCP1141L2 XZCP1241L2 XZCP1340L25 m XZCP0566L5 XZCP0666L5 5 m XZCP1865L5 XZCP1965L5 5 m XZCP1141L5 XZCP1241L5 XZCP1340L510 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10StraightElbowed10Other versions: please consult our Customer Care Centre.1/19


<strong>OsiSense</strong> <strong>XS</strong>Inductive proximity sensorsRectangular plastic1Non fl ushmountableFlushmountableU 8 x 22 x 8 U 15 x 32 x 8 U 26 x 26 x 13 U 40 x 40 x 15 U 80 x 80 x 262345678910Nominal sensing distance Sn 2.5 mm 5 mm 10 mm 15 mm 40 mmUsable sensing distance S (mm) fl ush mountable / non fl ush mountable 0...2 0...4 0…8 0…12 0…32Fine adjustment zone (mm) fl ush mountable / non fl ush mountable – – – – –Suitability for flush mounting (metal environment) flush mountable flush mountable flush mountable flush mountable flush mountableTemperature range (°C) - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70Product certification CE CE - UL - CSA - C-TICKDegree of protection (conforming to IEC 60529) pre-cabled: IP 68 (with connector: IP 67)Sensors for DC applicationsConnection Pre-cabled, PvR (2 m)2-wire (non polarised) NO or NC programmable – – – – –2-wire non NO function <strong>XS</strong>7J1A1DAL2 <strong>XS</strong>7F1A1DAL2 <strong>XS</strong>7E1A1DAL2 <strong>XS</strong>7C1A1DAL2 <strong>XS</strong>7D1A1DAL2polarisedNC function <strong>XS</strong>7J1A1DBL2 <strong>XS</strong>7F1A1DBL2 <strong>XS</strong>7E1A1DBL2 <strong>XS</strong>7C1A1DBL2 <strong>XS</strong>7D1A1DBL24-wire PNP NO + NC complementary outputs – – – – –NPN NO + NC complementary outputs – – – – –3-wire PNP NO function <strong>XS</strong>7J1A1PAL2 <strong>XS</strong>7F1A1PAL2 <strong>XS</strong>7E1A1PAL2 <strong>XS</strong>7C1A1PAL2 <strong>XS</strong>7D1A1PAL2NC function <strong>XS</strong>7J1A1PBL2 <strong>XS</strong>7F1A1PBL2 <strong>XS</strong>7E1A1PBL2 <strong>XS</strong>7C1A1PBL2 <strong>XS</strong>7D1A1PBL2NPN NO function <strong>XS</strong>7J1A1NAL2 <strong>XS</strong>7F1A1NAL2 <strong>XS</strong>7E1A1NAL2 <strong>XS</strong>7C1A1NAL2 <strong>XS</strong>7D1A1NAL2NC function <strong>XS</strong>7J1A1NBL2 <strong>XS</strong>7F1A1NBL2 <strong>XS</strong>7E1A1NBL2 <strong>XS</strong>7C1A1NBL2 <strong>XS</strong>7D1A1NBL2Connection M8 connector M12 connector2-wire non NO function <strong>XS</strong>7J1A1DAL01M8 (1) <strong>XS</strong>7F1A1DAL01M8 (1) <strong>XS</strong>7E1A1DAM8 <strong>XS</strong>7C1A1DAM8 <strong>XS</strong>7D1A1DAM12polarisedNC function <strong>XS</strong>7J1A1DBL01M8 (1) <strong>XS</strong>7F1A1DBL01M8 (1) <strong>XS</strong>7E1A1DBM8 <strong>XS</strong>7C1A1DBM8 <strong>XS</strong>7D1A1DBM123-wire PNP NO function <strong>XS</strong>7J1A1PAL01M8 (1) <strong>XS</strong>7F1A1PAL01M8 (1) <strong>XS</strong>7E1A1PAM8 <strong>XS</strong>7C1A1PAM8 <strong>XS</strong>7D1A1PAM12NC function <strong>XS</strong>7J1A1PBL01M8 (1) <strong>XS</strong>7F1A1PBL01M8 (1) <strong>XS</strong>7E1A1PBM8 <strong>XS</strong>7C1A1PBM8 <strong>XS</strong>7D1A1PBM12NPN NO function <strong>XS</strong>7J1A1NAL01M8 (1) <strong>XS</strong>7F1A1NAL01M8 (1) <strong>XS</strong>7E1A1NAM8 <strong>XS</strong>7C1A1NAM8 <strong>XS</strong>7D1A1NAM12NC function <strong>XS</strong>7J1A1NBL01M8 (1) <strong>XS</strong>7F1A1NBL01M8 (1) <strong>XS</strong>7E1A1NBM8 <strong>XS</strong>7C1A1NBM8 <strong>XS</strong>7D1A1NBM12Supply voltage limits, min./max. (V) including ripple 10…36 10…36 10…36 10…36 10…36Switching capacity, max. (mA) 100 100 100 100 100Short-circuit protect. (g) / LED output state indicator (⊗) / Power on LED (⊗) g / ⊗ / – g / ⊗ / – g / ⊗ / – g / ⊗ / – g / ⊗ / –Voltage drop, closed state (V) at I nominal cable / Connector ≤ 4 / ≤ 2 ≤ 4 / ≤ 2 ≤ 2 ≤ 2 ≤ 2Switching frequency (Hz) cable / Connector 4000 / 2000 5000 / 2000 1000 1000 100Multi-current/multi-voltage sensors for AC/DC applicationsConnection2-wire AC/DC NO function – – – – –NC function – – – – –AC NO or NC programmable – – – – –AC/DC NO or NC programmable – – – – –Connection2-wire AC/DC NO function – – – – –NC function – – – – –Supply voltage limits, min./max. (V) including ripple – – – – –Switching capacity, max. (mA) – – – – –Short-circuit protect. (g) / LED output state indicator (⊗) / Power on LED (⊗) – – – – –Residual current, open state (mA) – – – – –Voltage drop, closed state (V) at I nominal – – – – –Switching frequency (Hz) – – – – –(1) M8 connector on flying lead (L = 0.15 m).AccessoriesFixing for flat sensorsSuitable female plug-in connectorsfl atflat 90° M8 Straight Elbowed90° 8x22x8 <strong>XS</strong>ZBJ00 <strong>XS</strong>ZBJ90 Metal ring XZCC8FDM30S XZCC8FCM30S15x32x8 <strong>XS</strong>ZBF00 <strong>XS</strong>ZBF90 M12 (4 pin)26x26x13 <strong>XS</strong>ZBE00 <strong>XS</strong>ZBE90 Metal ring XZCC12FDM40B XZCC12FCM40B40x40x15 <strong>XS</strong>ZBC00 <strong>XS</strong>ZBC90 Plastic ring XZCC12FDP40B XZCC12FCP40B1/20Other versions: please consult our Customer Care Centre.


1U 40 x 40 x 117 U 26 x 26 x 13 U 40 x 40 x 15 U 80 x 80 x 2615 mm 20 mm increased range 20 mm 40 mm increased range 15 mm 25 mm 60 mm0…12 0…16 0…16 0…32 0…8 / 0...12 0…12 / 0...20 0…32 / 0...485...10 / 5...15 8...15 / 8...25 20...40 / 20...60flush mountable non flush mountable flush mountable or non fl ush mountable via teach mode- 25…+ 70 - 25…+ 70CE - UL - CSA - CCC - C-TICKCE - UL - CSA - CCC - C-TICKIP 67 pre-cabled: IP 68 (with connector: IP 67)Screw terminals (2) Pre-cabled (2 m)<strong>XS</strong>7C40DP210 – <strong>XS</strong>8C40DP210 – – – –<strong>XS</strong>7C40DA210 – <strong>XS</strong>8C40DA210 – – – –– – – – – – –<strong>XS</strong>7C40PC440 <strong>XS</strong>7C40PC449 <strong>XS</strong>8C40PC440 <strong>XS</strong>8C40PC449 – – –<strong>XS</strong>7C40NC440 <strong>XS</strong>7C40NC449 <strong>XS</strong>8C40NC440 <strong>XS</strong>8C40NC449 – – –– – – – <strong>XS</strong>8E1A1PAL2 <strong>XS</strong>8C1A1PAL2 <strong>XS</strong>8D1A1PAL2– – – – <strong>XS</strong>8E1A1PBL2 <strong>XS</strong>8C1A1PBL2 <strong>XS</strong>8D1A1PBL2– – – – <strong>XS</strong>8E1A1NAL2 <strong>XS</strong>8C1A1NAL2 <strong>XS</strong>8D1A1NAL2– – – – <strong>XS</strong>8E1A1NBL2 <strong>XS</strong>8C1A1NBL2 <strong>XS</strong>8D1A1NBL2M8 connector M8 connector M12 connector– – – – – – –– – – – – – –– – – – <strong>XS</strong>8E1A1PAM8 <strong>XS</strong>8C1A1PAM8 <strong>XS</strong>8D1A1PAM12– – – – <strong>XS</strong>8E1A1PBM8 <strong>XS</strong>8C1A1PBM8 <strong>XS</strong>8D1A1PBM12– – – – <strong>XS</strong>8E1A1NAM8 <strong>XS</strong>8C1A1NAM8 <strong>XS</strong>8D1A1NAM12– – – – <strong>XS</strong>8E1A1NBM8 <strong>XS</strong>8C1A1NBM8 <strong>XS</strong>8D1A1NBM1212…48 10…36 10…36 10…364-wire version = 200 – 2-wire version = 1.5…100 100 200 2004-wire version = g / ⊗ / ⊗ – 2-wire version = g / ⊗ / – g / ⊗ / ⊗ g / ⊗ / ⊗ g / ⊗ / ⊗4-wire version = ≤ 2 – 2-wire version = ≤ 4 ≤ 2 ≤ 2 ≤ 22-wire = 1500 / 4-wire = 1000 2-wire = 800 / 4-wire = 1000 (20mm) 500 (40mm) 2000 1000 150Screw terminals (2) Pre-cabled (2 m)– – – – <strong>XS</strong>8E1A1MAL2 <strong>XS</strong>8C1A1MAL2 <strong>XS</strong>8D1A1MAL2– – – – <strong>XS</strong>8E1A1MBL2 <strong>XS</strong>8C1A1MBL2 <strong>XS</strong>8D1A1MBL2<strong>XS</strong>7C40FP260 – <strong>XS</strong>8C40FP260 – – – –<strong>XS</strong>7C40MP230 – <strong>XS</strong>8C40MP230 – – – –1/2"-20 UNF connector– – – – <strong>XS</strong>8E1A1MAL01U20 <strong>XS</strong>8C1A1MAL01U20 <strong>XS</strong>8D1A1MAU20– – – – <strong>XS</strong>8E1A1MBL01U20 <strong>XS</strong>8C1A1MBL01U20 <strong>XS</strong>8D1A1MBU2020…264 20…264 20…264 20…264AC version = 500 – AC/DC version = 300 / 200 200 AC or DC 300 AC / 200 DC 300 AC / 200 DC– / ⊗ / – – / ⊗ / ⊗ – / ⊗ / ⊗ – / ⊗ / ⊗AC version = ≤ 1.5 – AC/DC version = ≤ 0.8 / 1.5 ≤ 1.5 ≤ 1.5 ≤ 1.5≤ 5.5 ≤ 5.5 ≤ 5.5 ≤ 5.525 AC / 50 DC 2000 1000 150(2) Sensors supplied without cable gland. Suitable cable gland: 13P. Also available in M20, 1/2" NPT output and M12, 7/8" connectors.23456789Pre-wired connectors M8 (3 pin) 1/2" M12 (4 pin)Straight Elbowed Straight Elbowed Straight Elbowed Elbowed PNP LED2 m XZCP0566L2 XZCP0666L2 2 m XZCP1865L2 XZCP1965L2 2 m XZCP1141L2 XZCP1241L2 XZCP1340L25 m XZCP0566L5 XZCP0666L5 5 m XZCP1865L5 XZCP1965L5 5 m XZCP1141L5 XZCP1241L5 XZCP1340L510 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10StraightElbowed10Other versions: please consult our Customer Care Centre.1/21


<strong>OsiSense</strong> <strong>XS</strong>Inductive proximity sensorsCylindrical Plastic1Non flushmountableFlushmountableM8 M12 M18 M3023456789Nominal sensing distance Sn 2.5 mm 4 mm 8 mm 15 mmOperating zone (mm) 0…2 0…3.2 0…6.4 0…12Suitability for flush mounting (metal environment)non flush mountableTemperature range (°C) - 25…+ 70Product certificationCE - UL - CSA - CCC - C-TICKDegree of protection (conforming to IEC 60529) IP 67 pre-cabled: IP 68 (with connector: IP 67)Sensors for DC applicationsConnection Pre-cabled, PvR (2 m)Dimensions (mm) Ø x L or W x H x D M8 x 33 M12 x 33 M18 x 33.5 M30 x 40.52-wire (non polarised) NO or NC programmable – – – –4-wire PNP NO + NC complementary outputs – – – –NPN NO + NC complementary outputs – – – –3-wire PNP NO function <strong>XS</strong>4P08PA340 <strong>XS</strong>4P12PA340 <strong>XS</strong>4P18PA340 <strong>XS</strong>4P30PA340NC function <strong>XS</strong>4P08PB340 <strong>XS</strong>4P12PB340 <strong>XS</strong>4P18PB340 <strong>XS</strong>4P30PB340NPN NO function <strong>XS</strong>4P08NA340 <strong>XS</strong>4P12NA340 <strong>XS</strong>4P18NA340 <strong>XS</strong>4P30NA340NC function <strong>XS</strong>4P08NB340 <strong>XS</strong>4P12NB340 <strong>XS</strong>4P18NB340 <strong>XS</strong>4P30NB340Connection M8 connector M12 connectorDimensions (mm) Ø x L or W x H x D M8 x 42 M12 x 48 M18 x 48 M30 x 503-wire PNP NO function <strong>XS</strong>4P08PA340S <strong>XS</strong>4P12PA340D <strong>XS</strong>4P18PA340D <strong>XS</strong>4P30PA340DNC function <strong>XS</strong>4P08PB340S <strong>XS</strong>4P12PB340D <strong>XS</strong>4P18PB340D <strong>XS</strong>4P30PB340DNPN NO function <strong>XS</strong>4P08NA340S <strong>XS</strong>4P12NA340D <strong>XS</strong>4P18NA340D <strong>XS</strong>4P30NA340DNC function <strong>XS</strong>4P08NB340S <strong>XS</strong>4P12NB340D <strong>XS</strong>4P18NB340D <strong>XS</strong>4P30NB340DSupply voltage limits, min./max. (V) including ripple 10…38 10…38 10…38 10…38Switching capacity, max. (mA) 200 200 200 200Short-circuit protect. (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗ g / ⊗Voltage drop, closed state (V) at I nominal ≤ 2 ≤ 2 ≤ 2 ≤ 2Switching frequency (Hz) 5000 5000 2000 1000Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled, PvR (2 m)Dimensions (mm) Ø x L or W x D x H M8 x 50 M12 x 50 M18 x 60 M30 x 602-wire AC/DC NO function <strong>XS</strong>4P08MA230 <strong>XS</strong>4P12MA230 <strong>XS</strong>4P18MA230 <strong>XS</strong>4P30MA230not short-circuit protected (1) NC function <strong>XS</strong>4P08MB230 <strong>XS</strong>4P12MB230 <strong>XS</strong>4P18MB230 <strong>XS</strong>4P30MB230AC NO or NC programmable – – – –AC/DC NO or NC programmable – – – –Connection1/2" connectorDimensions (mm) Ø x L or W x H x D M8 x 61 M12 x 61 M18 x 70 M30 x 702-wire AC/DC NO function <strong>XS</strong>4P08MA230K <strong>XS</strong>4P12MA230K <strong>XS</strong>4P18MA230K <strong>XS</strong>4P30MA230Knot short-circuit protected (1) NC function <strong>XS</strong>4P08MB230K <strong>XS</strong>4P12MB230K <strong>XS</strong>4P18MB230K <strong>XS</strong>4P30MB230KSupply voltage limits, min./max. (V) including ripple 20…264 20…264 20…264 20…264Switching capacity, max. (mA) 100 200 300 AC / 200 DC 300 AC / 200 DCLED output state indicator (⊗) ⊗ ⊗ ⊗ ⊗Residual current, open state (mA) ≤ 0.6 ≤ 0.6 ≤ 0.6 ≤ 0.6Voltage drop, closed state (V) at I nominal ≤ 5.5 ≤ 5.5 ≤ 5.5 ≤ 5.5Switching frequency (Hz) 25 AC / 3000 DC 25 AC / 3000 DC 25 AC / 2000 DC 25 AC / 1000 DC(1) For these sensors without short-circuit protection, it is essential to connect a 0.4 A quick-blow fuse in series with the load.10AccessoriesFixing for cylindrical sensorsFixing clamp with indexing pinfor cylindrical sensors1/22Suitable female plug-in connectorsM8 Straight ElbowedM4 <strong>XS</strong>ZB104 M12 <strong>XS</strong>ZB112 Metal ring XZCC8FDM30S XZCC8FCM30SM5 <strong>XS</strong>ZB105 M18 <strong>XS</strong>ZB118 M12 (4 pin)M6.5 <strong>XS</strong>ZB165 M30 <strong>XS</strong>ZB130 Metal ring XZCC12FDM40B XZCC12FCM40BM8 <strong>XS</strong>ZB108 Plastic ring XZCC12FDP40B XZCC12FCP40BOther versions: please consult our Customer Care Centre.


Miniature cylindrical metal (assembly)1Ø 4 M5 Ø 6.5Nominal sensing distance Sn 1 mm 1 mm 1.5 mm 2.5 mmOperating zone (mm) 0…0.8 0…0.8 0…1.2 0…2Suitability for flush mounting (metal environment)flush mountableTemperature range (°C) - 25…+ 70Product certificationCE - UL - CSA - CCC - C-TICKDegree of protection (conforming to IEC 60529) IP 67Sensors for DC applicationsDimensions (mm) Ø x L Ø 4 x 29 M5 x 29 Ø 6.5 x 33Connection Pre-cabled, PvR (2 m)3-wire PNP NO function <strong>XS</strong>1L04PA310 <strong>XS</strong>1N05PA310 <strong>XS</strong>506B1PAL2 <strong>XS</strong>106B3PAL2NC function – – <strong>XS</strong>506B1PBL2 <strong>XS</strong>106B3PBL2NPN NO function <strong>XS</strong>1L04NA310 <strong>XS</strong>1N05NA310 <strong>XS</strong>506B1NAL2 <strong>XS</strong>106B3NAL2NC function – – <strong>XS</strong>506B1NBL2 <strong>XS</strong>106B3NBL22-wire (polarised) NO function – – <strong>XS</strong>506BSCAL2 <strong>XS</strong>606B3CAL2NC function – – <strong>XS</strong>506BSCBL2 <strong>XS</strong>606B3CBL2Dimensions (mm) Ø x L Ø 4 x 41 M5 x 41 Ø 6.5 x 42ConnectionM83-wire PNP NO function <strong>XS</strong>1L04PA310S <strong>XS</strong>1N05PA311S (1) <strong>XS</strong>506B1PAM8 <strong>XS</strong>106B3PAM8NC function – – <strong>XS</strong>506B1PBM8 <strong>XS</strong>106B3PBM8NPN NO function <strong>XS</strong>1L04NA310S <strong>XS</strong>1N05NA311S (1) <strong>XS</strong>506B1NAM8 <strong>XS</strong>106B3NAM8NC function – – <strong>XS</strong>506B1NBM8 <strong>XS</strong>106B3NBM8ConnectionM122-wire (polarised) fonction NO – – <strong>XS</strong>506BSCAL01M12 <strong>XS</strong>506B3CAL01M12Supply voltage limits, min./max. (V) including ripple 5…30 5…30 10…36Switching capacity, max. (mA) 3-wire / 2-wire 100 / – 100 / – 200 / 100Short-circuit protect. (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗Voltage drop, closed state (V) at I nominal 3-wire / 2-wire ≤ 2 / – ≤ 2 / – ≤ 2 / ≤ 4Switching frequency (Hz) 3-wire / 2-wire 5000 / – 5000 / – 5000 / 4000 2500 / 3000(1) Stainless steel sensors, Sn = 0.8 mm23456789Pre-wired connectors M8 (3 pin) 1/2" M12 (4 pin)Straight Elbowed Straight Elbowed Straight Elbowed Elbowed PNP LED2 m XZCP0566L2 XZCP0666L2 2 m XZCP1865L2 XZCP1965L2 2 m XZCP1141L2 XZCP1241L2 XZCP1340L25 m XZCP0566L5 XZCP0666L5 5 m XZCP1865L5 XZCP1965L5 5 m XZCP1141L5 XZCP1241L5 XZCP1340L510 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10StraightElbowed10Other versions: please consult our Customer Care Centre.1/23


<strong>OsiSense</strong> <strong>XS</strong>Inductive proximity sensorsMulti-voltage with short-circuit protection1Non flushmountableFlushmountableM12 M18 M30234567Sensing distance Sn flush mountable 2 mm 5 mm 10 mmnon flush mountable 4 mm 8 mm 15 mmOperating zone (mm) flush mountable 0…1.6 0…4 0…8non flush mountable 0…3.2 0…6.4 0…12Suitability for flush mounting (metal environment)flush mountable or non flush mountable depending on modelCase M (metal) P (plastic)MTemperature range (°C) - 25…+ 70Degree of protection (conforming to IEC 60529) IP 68 (with connector: IP 67)Product certificationCE - UL - CSA - CCC - C-TICKDimensions (mm) Ø x L Cable (Connector) M12 x 55 (M12 x 66) M18 x 60 (M18 x 72) M30 x 60 (M30 x 72)Sensors for DC applicationsConnection4-wire PNP NO + NC flush mountable – – –non flush mountable – – –NPN NO + NC flush mountable – – –non flush mountable – – –PNP+NPN NO/NC flush mountable (metal) – – –programmable non flush mntbl. (metal) – – –non flush mntbl. (plastic) – – –Connection4-wire PNP NO + NC flush mountable – – –non flush mountable – – –NPN NO + NC flush mountable – – –non flush mountable – – –PNP+NPN NO/NC flush mountable (metal) – – –programmable non flush mntbl. (metal) – – –non flush mntbl. (plastic) – – –Supply voltage limits, min./max. (V) including ripple – – –Switching capacity, max. (mA) – – –Short-circuit protection (g) / LED output state indicator (⊗) – – –Voltage drop, closed state (V) at I nominal – – –Switching frequency (Hz) – – –Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled, PvR (2 m)89102-wire AC/DC NO function flush mountable <strong>XS</strong>1M12MA250 <strong>XS</strong>1M18MA250 <strong>XS</strong>1M30MA250non flush mountable <strong>XS</strong>2M12MA250 <strong>XS</strong>2M18MA250 <strong>XS</strong>2M30MA250NC function flush mountable <strong>XS</strong>1M12MB250 <strong>XS</strong>1M18MB250 <strong>XS</strong>1M30MB250non flush mountable <strong>XS</strong>2M12MB250 <strong>XS</strong>2M18MB250 <strong>XS</strong>2M30MB250Connection1/2"-20 UNF connector2-wire AC/DC NO function flush mountable <strong>XS</strong>1M12MA250K <strong>XS</strong>1M18MA250K <strong>XS</strong>1M30MA250Knon flush mountable <strong>XS</strong>2M12MA250K <strong>XS</strong>2M18MA250K <strong>XS</strong>2M30MA250KNC function flush mountable <strong>XS</strong>1M12MB250K <strong>XS</strong>1M18MB250K <strong>XS</strong>1M30MB250Knon flush mountable <strong>XS</strong>2M12MB250K <strong>XS</strong>2M18MB250K <strong>XS</strong>2M30MB250KSupply voltage limits, min./max. (V) 50-60 Hz 20…264Switching capacity, max. (mA) 5…200 5…200 AC, 5…300 DCLED output state indicator (⊗) / Power on LED (⊗)⊗ / ⊗Residual current, open state (mA) ≤ 1.5Voltage drop, closed state (V) at I nominal ≤ 5.5Switching frequency (Hz) 25 AC, 4000 DC 25 AC, 2000 DC 25 AC, 2000 DC (1)(1) 25 AC, 1000 DC for non flush mountable Ø 30 mm.1/24Other versions: please consult our Customer Care Centre.


PNP or NPNNO + NC Complementary outputsPNP + NPN outputs,NO or NC programmable1M8 M12 M18 M30 M12 M18 M301.5 mm 2 mm 5 mm 10 mm 2 mm 5 mm 10 mm2.5 mm 4 mm 8 mm 15 mm 4 mm 8 mm 15 mm0…1.2 0…1.6 0…4 0…8 0…1.6 0…4 0…80…2 0…3.2 0…6.4 0…12 0…3.2 0…6.4 0…12flush mountable or non flush mountable depending on modelflush mountable or non flush mountable depending on modelMM or P depending on model- 25…+ 70 - 25…+ 70IP 67 IP 68 (with connector: IP 67) IP 68 (with connector: IP 67)CE - UL - CSA - CCC - C-TICKCE - UL - CSA - CCC - C-TICKM8 x 50 (M8 x 61) M12 x 33 (M12 x 48) M18 x 36.5 (M18 x 49) M30 x 40.5 (M30 x 53) M12 x 50 (M12 x 61) M18 x 60 (M18 x 72) M30 x 60 (M30 x 72)23Pre-cabled, PvR (2 m) Pre-cabled, PvR (2 m)<strong>XS</strong>1M08PC410 <strong>XS</strong>1N12PC410 <strong>XS</strong>1N18PC410 <strong>XS</strong>1N30PC410 – – –<strong>XS</strong>2M08PC410 <strong>XS</strong>2N12PC410 <strong>XS</strong>2N18PC410 <strong>XS</strong>2N30PC410 – – –<strong>XS</strong>1NM08NC410 <strong>XS</strong>1N12NC410 <strong>XS</strong>1N18NC410 <strong>XS</strong>1N30NC410 – – –<strong>XS</strong>2M08NC410 <strong>XS</strong>2N12NC410 <strong>XS</strong>2N18NC410 <strong>XS</strong>2N30NC410 –– – – – <strong>XS</strong>1M12KP340 <strong>XS</strong>1M18KP340 <strong>XS</strong>1M30KP340– – – – <strong>XS</strong>2M12KP340 <strong>XS</strong>2M18KP340 <strong>XS</strong>2M30KP340– – – – <strong>XS</strong>4P12KP340 <strong>XS</strong>4P18KP340 <strong>XS</strong>4P30KP340M12 connectorM12 connector<strong>XS</strong>1M08PC410D <strong>XS</strong>1N12PC410D <strong>XS</strong>1N18PC410D <strong>XS</strong>1N30PC410D – – –<strong>XS</strong>2M08PC410D <strong>XS</strong>2N12PC410D <strong>XS</strong>2N18PC410D <strong>XS</strong>2N30PC410D – – –<strong>XS</strong>1M08NC410D <strong>XS</strong>1N12NC410D <strong>XS</strong>1N18NC410D <strong>XS</strong>1N30NC410D – – –<strong>XS</strong>2M08NC410D <strong>XS</strong>2N12NC410D <strong>XS</strong>2N18NC410D <strong>XS</strong>2N30NC410D – – –– – – – <strong>XS</strong>1M12KP340D <strong>XS</strong>1M18KP340D <strong>XS</strong>1M30KP340D– – – – <strong>XS</strong>2M12KP340D <strong>XS</strong>2M18KP340D <strong>XS</strong>2M30KP340D– – – – <strong>XS</strong>4P12KP340D <strong>XS</strong>4P18KP340D <strong>XS</strong>4P30KP340D10…36 10…36200 200g / ⊗ g / –≤ 2 ≤ 2.65000 5000 2000 1000 5000 2000 10004567PNPPNPNONC+–NPNNPNNONC+–NONPNPNP+ BN/1- BU/3NCNPNPNP+ BU/3- BN/18AccessoriesFixing clampsWith indexing pin for cylindrical sensorsSuitable female plug-in connectors, including pre-wired versionslength 5 mpre-wired,pre-wired,without LEDelbowedstraightscrew terminal9M8 <strong>XS</strong>ZB108M12 <strong>XS</strong>ZB112 M8 (or S) XZCP0666L5 XZCP0566L5 XZCC8FCM30SM18 <strong>XS</strong>ZB118 M12 (or D) XZCP1241L5 XZCP1141L5 XZCC12FCM40BM30 <strong>XS</strong>ZB130 1/2" (or K) XZCP1965L5 XZCP1865L5 XZCC20FCM30B10Other versions: please consult our Customer Care Centre.1/25


<strong>OsiSense</strong> <strong>XS</strong>Inductive proximity sensors - ApplicationRotation controlFixed sensing distance(for ferrous or non ferrous materials)1Non flushmountableFlushmountable234567891026 x 26 x 13 40 x 40 x 15 M30 M18 M30Nominal sensing distance Sn 10 mm 15 mm 10 mm 5 mm 10 mmOperating zone (mm) 0...8 0...12 0...8 0...4 0...8Suitability for flush mounting (metal environment) flush mountable flush mountableCase M (metal) P (plastic) P P M M MTemperature range (°C) - 25…+ 70 0…+ 50Degree of protection (conforming to IEC 60529) IP 67 pre-cabled: IP 68 (with connector: IP 67)Product certification CE - UL - CSA - CCC - C-TICK CE - UL - CSA - CCC - C-TICKDimensions (mm) Ø x L or W x H x D Cable (Connector) 26 x 26 x 13 40 x 40 x 15 M30 x 81 M18 x 60 (M18 x 70) M30 x 60Maximum speed of passing object (impulses/min) 48000 48000 6000...48000 (1) – –Adjustable frequency range (impulses/min) 6...6000 6...6000 6...150 / 120...3000 (1) – –Sensors for DC applicationsConnection Pre-cabled, PvR (2 m)4-wire PNP/NPN NO/NC programmable – – – <strong>XS</strong>1M18KPM40 <strong>XS</strong>1M30KPM403-wire PNP NC function slow version – – <strong>XS</strong>AV11373 – –fast version – – <strong>XS</strong>AV12373 – –0…10 V output plastic – – – – –4…20 mA output metal, flush mountable – – – – –plastic, flush mountable – – – – –plastic, non flush mountable – – – – –Connection M8 or M12 connector M12 on 0.8 m flying lead4-wire PNP/NPN NO/NC programmable – – – <strong>XS</strong>1M18KPM40D <strong>XS</strong>1M30KPM40LD3-wire PNP NC function <strong>XS</strong>9E11RPBL01M12 (3) <strong>XS</strong>9C11RPBL01M12 (3) – – –0…10 V output – – – – –4…20 mA output – – – – –Supply voltage limits, min./max. (V) including ripple 10...36 10...36 10...58 10...38Switching capacity, max. (mA) 100 200 200 200Short-circuit protect. (g) / LED output state indicator (⊗) / Power on LED (⊗) (⊗) g / ⊗ / ⊗ g / ⊗ / ⊗ g / ⊗ / – g / ⊗ / –Linearity error – – – –Voltage drop, closed state (V) at I nominal ≤ 2 ≤ 2 ≤ 2 ≤ 2.6Switching frequency (Hz) – – – 1000Operating frequency (Hz) – – – –Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled, PvR (2 m)2-wire AC/DC NC function <strong>XS</strong>9E11RMBL01U20 (5) <strong>XS</strong>9C11RMBL01U20 (5) – – –not short-circuit protected (2) NC function slow version – – <strong>XS</strong>AV11801 – –fast version – – <strong>XS</strong>AV12801 – –Supply voltage limits, min./max. (V) 50-60 Hz 20...264 20...264 20...264 – –Switching capacity, max. (mA) 100 300 AC / 200 DC 300 AC / 200 DC – –LED output state indicator (⊗) / Power on LED (⊗) ⊗ / ⊗ ⊗ / ⊗ ⊗ / – – –Residual current, open state (mA) ≤ 1.5 ≤ 1.5 ≤ 1.5 – –Voltage drop, closed state (V) at I nominal ≤ 5.5 ≤ 5.5 ≤ 5.7 – –Switching frequency (Hz) – – – – –AccessoriesFixingfor flat sensors substitution Fixing clamp with indexing pinof block type for cylindrical sensors90°flat 90° sensors<strong>XS</strong>E / <strong>XS</strong>C / <strong>XS</strong>D8x22x8 <strong>XS</strong>ZBJ00 <strong>XS</strong>ZBJ90 –15x32x8 <strong>XS</strong>ZBF00 <strong>XS</strong>ZBF90 <strong>XS</strong>ZBE10 M12 <strong>XS</strong>ZB112flat26x26x13 <strong>XS</strong>ZBE00 <strong>XS</strong>ZBE90 <strong>XS</strong>ZBC10 M18 <strong>XS</strong>ZB11840x40x15 <strong>XS</strong>ZBC00 <strong>XS</strong>ZBC90 <strong>XS</strong>ZBD10 M30 <strong>XS</strong>ZB1301/26Other versions: please consult our Customer Care Centre.


Forks with teach mode (1)1System, with teach mode Thru-beam Thru-beam laserLaserclassSensing distance 2…120 mm 2…120 mmFixing (mm)(see column E below)Minimum size of objet detected 0,2 mm 0,05 mmCase M (metal) / Setting-up assistance LEDs ⊗M / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 60 / IP 65Product certificationCE - cULusSensors for DC applications (solid-state output: transistor)ConnectionM8 connector - 4 PinType of output3-wire PNP/NPN programmable NO/NCDimensions (mm) A B C D E A B C D ETransmitter / ReceiverDXUYFANEP40002 2 42 32 57 14 XUYFALNEP40002 2 42 41 57 14BXUYFANEP60002 2 59 77 XUYFALNEP60002 2 59 77XUYFANEP100002 2 95 110 XUYFALNEP100002 2 95 110XUYFANEP40005 5 42 35 57 14 XUYFALNEP40005 5 42 44 57 14EA C XUYFANEP60005 5 59 77 XUYFALNEP60005 5 59 77XUYFANEP100005 5 95 110 XUYFALNEP100005 5 95 110XUYFANEP40015 15 42 45 57 27 XUYFALNEP40015 15 42 54 57 27XUYFANEP60015 15 59 77 XUYFALNEP60015 15 59 77XUYFANEP100015 15 95 110 XUYFALNEP100015 15 95 110XUYFANEP40030 30 42 60 57 42 XUYFALNEP40030 30 42 69 57 42XUYFANEP60030 30 59 77 XUYFALNEP60030 30 59 77XUYFANEP100030 30 95 110 XUYFALNEP100030 30 95 110XUYFANEP40050 50 42 80 57 40 XUYFALNEP40050 50 42 89 57 40XUYFANEP60050 50 59 77 XUYFALNEP60050 50 59 77XUYFANEP100050 50 95 110 XUYFALNEP100050 50 95 110XUYFANEP40080 80 42 110 57 70 XUYFALNEP40080 80 42 119 57 70XUYFANEP60080 80 59 77 XUYFALNEP60080 80 59 77XUYFANEP100080 80 95 110 XUYFALNEP100080 80 95 110XUYFANEP40120 120 42 150 57 110 XUYFALNEP40120 120 42 159 57 110XUYFANEP60120 120 59 77 XUYFALNEP60120 120 59 77XUYFANEP100120 120 95 110 XUYFALNEP100120 120 95 110Supply voltage limits, min./max. (V) including ripple 10…30 10…30Switching capacity, max. (mA) / Switching frequency (Hz) 100/10 kHz 100/10 kHzOverload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗(1) To order a fork without teach mode, delete A of the reference. Ex: XUYFANEP40002 becomes XUYFNEP400022345678System Ultrasonic thru-beam Thru-beamSpecial transparent labelsFor all other opaque labelsSensing distance 3 mm version XUVU06M3KCNM8 XUYFA983003COS5 mm version – XUYFA983005COSSwitching frequency (Hz) 500 10 000Sensitivity adjustment Numerical +/- button Teach buttonConnectionM8 (4 pin)Case M (metal) / Setting-up assistance LEDs ⊗M / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 5…+ 55 / IP 65 - 20…+ 60 / IP 65Product certification CE CE - cULus910Other versions: please consult our Customer Care Centre.1/33


Materials handing series - Analogue outputEAnalogue outputHigh access gain for resistanceApplicationPosition controlto accumulation of dirtEESystem Diffuse Diffuse Thru-beamSensing distance 0.20...0.80 m 0.05...0.40 m 50 mFixing (mm) fixing ctrs: 30 - 11P cable gland M18 x 1 M18 x 1Sensitivity adjustment – Potentiometer PotentiometerCase M (metal) P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ M / ⊗ M / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 60 / IP 67 - 25…+ 55 / IP 67 - 25…+ 55 / IP 67Product certification CE - UL - CSA CE - UL - CSA CE - UL - CSA - C-TICKDimensions (mm) Ø x L or H x W x D 86 x 27 x 83 M18 x 95 M18 x 95Sensors for DC applicationsConnection Screw terminals M12 connector M12 connectorTransmitter / Receiver analogue 4-20 mA / 0-10 V XUJK803538 (5) – –analogue 4-20 mA – XU5M18AB20D XU2M18AP20D (5)Supply voltage limits, min./max. (V) including ripple 20…30 10…30 10…30Switching capacity, max. (mA) / Switching frequency (Hz) max: 20, min: 4 / 10000 max: 20, min: 4 / 20 100 / 30Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗(5) With 3-wire PNP output.1234FG5LaserclassApplicationF G F G F GSystem Diffuse, 0-10 V analogue output Diffuse,Sensing distance 1 Sensing distance 2 4-20 mA analogue outputSensing distance 40...60 mm 45...85 mm 80...300 mmMinimum size of object 1 mm 0.8 mm 1.5 x 3.5 mmFixing (mm)direct: 3 M4 holes, fixing centres 40 mmSensitivity adjustmentPotentiometerCase P (plastic) / Setting-up assistance LEDs ⊗P / ⊗Temperature range (°C) 0…+ 45°Product certificationCE - cULusDimensions (mm) H x W x D 50 x 17 x 50Sensors for DC applications (solid-state output: transistor)Connection M12 connector M12 connector M12 connectorTransmitter / Receiver 0…10 V XUYPCO925L1ANSP XUYPCO925L2ANSP XUYPCO925L3ANSPSupply voltage limits, min./max (V) including ripple 18…28 18…28Switching capacity, max. 3 mA / 0…10 V analogue output 3 mA / 4…20 mA analogue outputSwitching frequency (Hz) 40 40Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗LaserclassLaserclass6789AccessoriesSuitable female pre-wired plug-in connectorsFixing, for XUYPCO925M8 straight M12 straight M8 elbowed M12 elbowed2 m XZCP0941L2 XZCP1141L2 XZCP1041L2 XZCP1241L2 With protective cover Simple5 m XZCP0941L5 XZCP1141L5 XZCP1041L5 XZCP1241L5 XUY 9251-DF525567 XUY 925-DF52556810Other versions: please consult our Customer Care Centre.1/35


<strong>OsiSense</strong> XUPhoto-electric sensors - ApplicationPackaging series1HIJ234567ApplicationContrast sensorsHHHSystem Diffuse Sensor with Diffuse(with teach mode) plastic fibre optics (1) (with teach mode)Sensing distance 19 mm 18 mm 9 mm (2)Fixing (mm) direct: fixing centres 40 x 40 DIN rail direct: 21 x 28, M5 screwsSensitivity adjustment Teach button Teach button Teach buttonCase M (metal) P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ P / ⊗ M / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 10…+ 55 / IP 65 0 … + 40 / IP 65 - 10…+ 55 / IP 67Product certification CE - cULus CE - cULus CEDimensions (mm) Ø x L or H x W x D 50 x 15 x 50 30 x 13 x 60 96 x 31 x 64Sensors for DC applications (solid-state output: transistor)Connection M12 connector M8 connector M12 connectorTransmitter / Receiver 3-wire PNP NO function XUKR1PSMM12 – –3-wire NPN NO function XUKR1NSMM12 – –3-wire PNP / NPN programmable NO / NC – – XURK1KSMM12NPN NO function XUYDCFCO966S –Supply voltage limits, min./max. (V) including ripple 10…30 10…30 10…30Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 5000 100 / 20 k 200 / 10000(1) Suitable fibre optics, to be ordered separately:Sensing distance: 18 mm (L = 0.6 m: XUYFPDC61),60 mm (L = 1 m: XUYFPDC101)18 mm (L = 0.6 m / M8: XUYFPDCM861),60 mm (L = 1 m / M8: XUYFPDCM8101).(2) 7 mm with XURZ02; 18 mm with XURZ01.ApplicationLuminescence sensorsDetection of transparent materialsI JI JSystem Diffuse Lum. detection Reflex (with teach mode)(manual) via fibre optics (50 x 50 reflector included)Sensing distance 0.02…0.08 m dpg. on fibre & fitting (3) 0…1.4 m (4) 1.5 mFixing (mm) M18 x 1 DIN rail M18 x 1 direct: fixing ctrs. 40 x 40Sensitivity adjustment Potentiometer +/- numeric potentiometer Teach buttonCase M (metal) P (plastic) / Setting-up assistance LEDs ⊗ M / ⊗ P / ⊗ P / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55 / IP 67 0 … + 60 / IP 65 0…+ 55 / IP 67 - 25…+ 55 / IP 65Product certification CE - CSA - UL CE - cULus CE - UL - CSA - C-TICKDimensions (mm) Ø x L or H x W x D Ø 18 x 95 30 x 13 x 60 Ø 18 x 64 50 x 18 x 508910Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled, PVC (2 m)Transmitter / Receiver 3-wire PNP programmable NO / NC – – XUBTAPSNL2 (5) –3-wire NPN programmable NO / NC – – XUBTANSNL2 (5) –3-wire PNP / NPN programmable NO / NC – – – XUKT1KSML2Connection M12 connector M8 connector M12 connector M12 connectorTransmitter / Receiver 3-wire PNP fonction NO XU5M18U1D – – –3-wire PNP programmable NO / NC – – XUBTAPSNM12 (5) –3-wire NPN programmable NO / NC – – XUBTANSNM12 (5) –3-wire PNP / NPN programmable NO / NC – XUYAFLCO966S – XUKT1KSMM12Supply voltage limits, min./max. (V) including ripple 10…30 10…30 10…32 10…30Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 1000 100 / 5 100 / 1000 100 / 1500(3) Suitable fibre optics, to be ordered separately (usable Ø 1 mm): (L = 10 m: XUFZ910) (L = 20 m: XUFZ920) (L = 50 m: XUFZ950). End fittings see the fibre optic page(4) 0…0.8 m for versions with 90° head, to order replace the 8 e digit N by W. Example XUBTAPSNL2 becomes XUBTAPSWL2(5) Also available in stainless steel for food and beverage processing applications. To order, replace the letter A by S in the ref. Example: XUBTAPSNL2 becomes XUBTSPSNL2.AccessoriesSuitable female plug-in connectors, including pre-wired versionsL = 5 m, without LED Wired, elbowed Wired, straight Screw terminalM8 (or S) 4 pin XZCP0666L5 XZCP0566L5 XZCC8FCM30SM12 (or D) 4 pin XZCP1241L5 XZCP1141L5 XZCC12FCM40BM12 8 pin – <strong>XS</strong>ZMCR03 (3 m) –Lenses for colour markLens for 18 mm sensing distanceXURZ01Lens for 7 mm sensing distanceXURZ021/36Other versions: please consult our Customer Care Centre.


Packaging seriesN1Application Colour sensors Detection of aqueous liquidsSystem Diffuse Diffuse Thru-beam(with integral amplifi er) infraredSensing distance 0.02 m 0.040...0.060 m 0.2 m (1)Fixing (mm) direct: fixing ctrs. 40x40 drct: fxg ctrs. 68x42, M5 screws direct: fixing ctrs. 20Sensitivity adjustment Teach button Teach button PotentiometerCase M (metal) P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ M / ⊗ P / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 10…+ 55 / IP 65 - 10…+ 55 / IP 67 0…+ 40 / IP 65Product certification CE - cULus CE CEDimensions (mm) Ø x L or H x W x D 50 x 25 x 50 80 x 30 x 57 47 x 13 x 33Sensors for DC applications (solid-state output: transistor)Connection M12 connector - 8 pin Pre-cabled (2 m) Pre-cabled (2 m)Transmitter / Receiver 3-wire PNP NO function XUKC1PSMM12 XURC3PPML2 –3-wire NPN NO function XUKC1NSMM12 XURC3NPML2 –3-wire PNP / NPN programmable NO / NC – – XUMW1KSNL2Supply voltage limits, min./max. (V) including ripple 10…30 10…30 10.8…26.4Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 1500 100 / 1200 100 / 1000(1) Nominal sensing distance 50 m. Use between 10 and 20 cm, depending on application.N234Food/beverage processing series5Stainless steel version for resistance to harsh agentsSystem Multimode (3) Polarised reflex Diffuse (2) Thru-beam (2)50x50 mm reflectorincluded (2)Sensing distance (4) 3 / 2 m 0.15 / 0.10 m 20 / 15 mFixing (mm) M18 x 1 M18 x 1 M18 x 1 M18 x 1Case M (metal) M (stainless steel) M (stainless steel) M (stainless steel) M (stainless steel)Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55 / IP 67 - 25…+ 55 / IP 67 - 25…+ 55 / IP 67Product certificationCE - UL - CSA - C-TICKDimensions (mm) Ø x L Ø 18 x 64 Ø 18 x 62 Ø 18 x 62 Ø 18 x 64Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled, PvR (2 m)Transmitter / Receiver 3-wire PNP programmable NO / NC XUB0SPSNL2 XU9N18PP341 XU5N18PP341 XU2N18PP3413-wire NPN programmable NO / NC XUB0SNSNL2 XU9N18NP341 XU5N18NP341 XU2N18NP341ConnectionM12 connectorTransmitter / Receiver 3-wire PNP programmable NO / NC XUB0SPSNM12 XU9N18PP341D XU5N18PP341D XU2N18PP341D3-wire NPN programmable NO / NC XUB0SNSNM12 XU9N18NP341D XU5N18NP341D XU2N18NP341DThru-beam transmitter accessory pre-cabled (2 m) XUB0SKSNL2T – –connector XUB0SKSNM12T – –Supply voltage limits, min./max. (V) including ripple 10…36 10…30 10…30Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 250 100 / 500 100 / 500(2) Also available with 90° head. To order, add the letter W after the numbers 341 in the reference. Example: XU9N18PP341 becomes XU9N18PP341W or XU9N18PP341DW.(3) Also available with 90° head, to order replace the 8 e digit N by W. Example XUB0SPSNL2 becomes XUB0SPSWL2(4) Background suppression: 0.12 m - Diffuse: 0.3 m - Reflex polarised: 3 m - Thru beam: 20 m678910Other versions: please consult our Customer Care Centre.1/37


<strong>OsiSense</strong> XUPhoto-electric sensorswith background suppressionKP123ApplicationKPKSystem Background Diffuse with background suppressionsuppression Sensing distance 1 Sensing distance 2Sensing distance 1.5…80 mm 10…60 mm 30…110 mmMinium size of object – 0.3 mm 0.7 mmFixing (mm) 2 x Ø 3 holes / fxg. ctrs. 14.5 direct: 2 M3 holes, fixing centres 24 mmSensitivity adjustment Potentiometer Teach modeCase P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ PTemperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 50 / IP 65 & IP 67 - 20…+ 60°C / IP 67Product certification CE - cULus CE - cULusDimensions (mm) H x W x D 32 x 13 x 20 35.8 x 12 x 20LaserclassLaserclassSensors for DC applications (solid-state output: transistor)Connection M8 connector (1) - 4 Pin M8 connector- 4 Pin M8 connector- 4 Pin45Transmitter / Receiver PNP NO function XUYPSCO989SP – –NPN NO function XUYPSCO989SN – –PNP programmable NO / NC – XUYPSCO929L1SP XUYPSCO929L2SPSupply voltage limits, min./max. (V) including ripple 10…30 10…30 10…30Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 500 100 / 1000 100 / 1000Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗(1) For 2 m pre-cabled connection delete CO from the reference. Example: XUYPSCO989SP becomes XUYPS989SP.ML678ApplicationSystemBackgroundsuppressionLaserclassBackgroundsuppression, 2 chnls.Sensing distance 50…300 mm 50…600 mmMinimum size of object 0.5 mm –Fixing (mm) direct: 2 M4 holes, ctrs. 54 mm 2 x Ø 4 holes, fixing ctrs. 54Sensitivity adjustment Potentiometer PotentiometerCase P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ P / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 50 / IP 65 0…+ 60 / IP 40Product certificationCE - cULusDimensions (mm) H x W x D 60 x 18 x 60 60 x 18 x 60MLSensors for DC applications (solid-state output: transistor). Sensors with overload and short-circuit protection9ConnectionM8 connectorTransmitter / Receiver 3-wire PNP / NPN programmable NO / NC XUYPS1LCO965S XUYPS2CO945SSupply voltage limits, min./max. (V) including ripple 10…30 10…30Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 5000 100 / 37010AccessoriesPre-wired connectorsM8 (4 pin) M12 (4 pin) 7/8" (5 pin)Straight Elbowed Straight Elbowed Straight2 m XZCP0941L2 XZCP1041L2 2 m XZCP1141L2 XZCP1241L2 2 m XZCP1764L25 m XZCP0941L5 XZCP1041L5 5 m XZCP1141L5 XZCP1241L5 5 m XZCP1764L5StraightElbowed1/38Other versions: please consult our Customer Care Centre.


NewQObjets sur convoyeurApplicationSystemQDiffusewith adjustable background suppressionSensing distance 0…1 m 1.2 m 2 mFixing (mm)direct:fixing ctrs. 40 x 40M30 x 1.5 or M5,fixing ctrs. 30direct: fixing ctrs. 30/38to 40/50/74 M5 screwSensitivity adjustment – Potentiometer –Case P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ P / ⊗ P / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55 / IP 65 - 25…+ 55 / IP 67, Nema 4X - 25...+ 55 / IP 67Product certification CE - UL - CSA CE - UL - CSA CE - UL - CSADimensions (mm) H x W x D 50 x 18 x 50 95 x 45 x 44 92 x 30,5 x 71Sensors for DC applications (solid-state output: transistor). Sensors with overload and short-circuit protectionConnection Pre-cabled, PVC (2 m) Screw terminalsTransmitter / Receiver 3-wire PNP / NPN programmable NO / NC XUK8AKSNL2 XUC8AKSNL2 (3) XUX8AKSAT16 (3)ConnectionM12 connectorTransmitter / Receiver 3-wire PNP / NPN programmable NO / NC XUK8AKSNM12 XUC8AKSNM12 (3) XUX8AKSAM12Supply voltage limits, min./max. (V) including ripple 10…36 10…38 10…36Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 250 100 / 500 100 / 150123456SystèmeDiffusewith adjustable background suppressionSensing distance 70…120 mm 1.2 m 2 mFixing (mm) M18 x 1 M30 x 1.5 or M5, fixing ctrs. 30 direct: fixing ctrs. 30/38to 40/50/74 M5 screwSensitivity adjustment Potentiometer Potentiometer –Case M (metal) P (plastic) / Setting-up assistance LEDs ⊗ M / ⊗ P / ⊗ P / ⊗Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55°C / IP 67 - 25…+ 55 / IP 67, Nema 4X - 25...+ 55 / IP 67Product certification CE - UL - CSA CE - UL - CSA CE - UL - CSADimensions (mm) Ø x L or H x W x D M18 x 82 95 x 45 x 44 92 x 30,5 x 71Multi-current/multi-voltage sensors for AC/DC applicationsConnection Cable L = 2m Cable 2m / Connector 7/8" Screw terminalsTransmitter / Receiver AC/DC NO function XU8M18MA230 – –programmable NO / NC – XUC8ARCTL2 / XUC8ARCTU78 XUX8ARCTT16Supply voltage limits, min./max. (V) including ripple 20…264 20…264 20…264Switching capacity, max. (mA) / Switching frequency (Hz) 200 / 25 3000 / 20 3000 / 20Overload and short-circuit protection (g) / LED output state indicator (⊗) (2) / ⊗ – –(2) Sensor not short-circuit protected. Therefore, it is essential to connect a 0.4 A quick-blow fuse in series with the load.78910Other versions: please consult our Customer Care Centre.1/39


<strong>OsiSense</strong> XUPhoto-electric sensors, fibre opticAmplifier12345+/- potentiometer Teach Teach + Timer Teach + TimerMax. / usable sensing distanceDepending on fibre used, plastic onlyFixing (mm)DIN rail or direct: fixing centres 25, M3 screwsSensitivity adjustment +/- numeric potentiometer using teach mode +/- numeric potentiometer using teach modeCase P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ P / ⊗ P / ⊗ P / ⊗ and 4-digit displayTemperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 60 / IP 65 - 10…+ 55 / IP 65 (1) 0…+ 60 / IP 65 - 10…+ 55 / IP 65 (1)Product certification CE - cULus CE - cULus - cURus CE - cULus CE - cULus - cURusDimensions (mm) L x H x W 60 x 30 x 13 65 x 40 x 10 60 x 30 x 13 65 x 40 x 10Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled, PVC (2 m)References 3-wire PNP programmable NO / NC – XUDA1PSML2 – XUDA2PSML2Amplifier 3-wire NPN programmable NO / NC – XUDA1NSML2 – XUDA2NSML2ConnectionM8 connector - 4 PinReferences 3-wire PNP programmable NO / NC – XUDA1PSMM8 – XUDA2PSMM8Amplifier 3-wire NPN programmable NO / NC – XUDA1NSMM8 – XUDA2NSMM83-wire PNP/NPN programmable NO / NC XUYAFVCO966S (Glass) – XUYAFVCO946S (Glass) –XUYAFPCO966S (Plastic) – XUYAFPCO946S (Plastic) –Supply voltage limits, min./max. (V) including ripple 10…30 10.8...26.4 10…30 10.8...26.4Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 1000 100 / 1000 100 / 1000 time delayable 100 / 1000 time delayableOverload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗ g / ⊗(1) IP 65 with Ø 1 fibre/ IP 64 with Ø 0.5 fibre.Ecofibre system, assemble your own plastic fibres6Fibre Ø 1 mm Length = 10 m Length = 20 m Length = 50 mReferences XUFZ910 XUFZ920 XUFZ95078End fittingsSensing distance (mm) 70 200 800 1200 4000 1200Type with threaded end with plain end fitting, with plain end fitting, with threaded end with threaded end 90° mirror, withfitting Ø 3, L = 9 mm Ø 3, L = 9 mm fitting fitting threaded end fittingThread M8 x 1, L = 10 mm – – M6 x 1, L = 10 mm M6 x 1, L = 10 mm M6 x 1, L = 3 to 10 mmLens yes no yes yes yes yesReferences XUYA110 XUYA210 XUYA211 XUYA212 XUYA212 XUYA220910AccessoriesFor thru-beam system plastic fibre opticsLensesFor increasingsensing distance (pair) XUFZ01With 90° mirror(pair)Fixing clamp with lens (set of 2)Front screw fixingfor fibre opticsXUFZ920XUFZ02XUFZ04For all system plastic fibre opticsFibre trimmerFor trimming fibres tolength (included withall fibre optics) XUFZ11Protective metal tubingLength 1 m, for fibreswith threaded end fittingsFor M4 thread XUFZ210For M6 thread XUFZ310Plug-in pre-wired female connectorsCable length 5 m, without LEDpre-wired, elbowed pre-wired, straightXZCP1041L5XZCP0941L51/40Other versions: please consult our Customer Care Centre.


Plastic fibre optic light guides (length 2 m)Long range fibreswith integrated lens Long range fibres Flexible fibresM4 / M2.6 (1) M4 / L = 90 mm M3 / M2.6 (1) M8 / L = 20 mm M4 / M2.6 (1) M4 / M2.6 (1)SystemThru-beamSensing distance (mm) 200 or 1500 (2) 180 50 or 1000 (2) 2500 300 or 2000 (2) 100 or 750 (2)Fibre cross-sectionFibre Ø (mm) Ø 1 Ø 1 Ø 0.5 Ø 1 Ø 1.5 Ø 1Sheath Ø (mm) Ø 2.2 Ø 2.2 Ø 1 Ø 2.2 Ø 2.2 Ø 2.2Temperature range (°C) - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60References XUFN12301 XUFN12311 XUFN35301 XUFN2L01L2 XUFN2P01L2 XUFN2S01L2Fixing M4 x 0.7 M4 x 0.7 M3 x 0.5 M8 x 1.25 M2.6 x 0.45 / M4 x 0.7 M2.6 x 0.45 / M4 x 0.7(1) Can be used with 90° mirror XUFZ02 (see preceding page).(2) With lens accessory XUFZ01 (see preceding page)123M6 M4 / M6 M6/L = 90 mm M4 / M2.6SystemDiffuseSensing distance (mm) 70 60 60 15Fibre cross-section4Fibre Ø (mm) Ø 1 Ø 1+16 Ø 0.265 Ø 1 Ø 0.5 + 4 Ø 0.23Sheath Ø (mm) Ø 2.2 x 2 Ø 2.2 x 2 Ø 2.2 x 2 Ø 1 x 2Temperature range (°C) - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60References XUFN05321 XUFN05323 XUFN05331 XUFN02323Fixing M6 x 0.75 M6 x 0.75 / M4 x 0.7 M6 x 0.75 M4 x 0.75Long range fibresM4 / L = 90 mm M4 / M2.6 M6 / L = 15 mmSystemDiffuseSensing distance (mm) 18 18 95Fibre cross-sectionFibre Ø (mm) Ø 0.5 Ø 0.5 Ø 1.5Sheath Ø (mm) Ø 1 x 2 Ø 1 x 2 Ø 2.2 x 2Temperature range (°C) - 25...+ 60 - 25...+ 60 - 25...+ 60References XUFN01331 XUFN01321 XUFN5P01L2Fixing M4 x 0.7 M4 x 0.7 M6 x 0.75Glass fibre optic light guides (length 0.6 m)678M4 M4 / Ø 2.5 x 89 M4 M4 / Ø 2.5 x 89 M4System Thru-beam DiffuseSensing distance (mm) 200 80Fibre cross- section9End fitting Straight Adaptable Straight Adaptable 90°Fibre Ø (mm) 1 1Sheath Ø (mm) 2.2 2.2Temperature range (°C) PVC sheath: - 25…+ 60 / Metal wound: - 25…+ 120 / Flexible stainless steel: - 25…+ 200References PVC sheath XUYFVERSD61 XUYFVERSC61 XUYFVPSD61 XUYFVPSC61 XUYFVPSL61Metal wound XUYFVERMD61 XUYFVERSC61 XUYFVPMD61 XUYFVPMC61 XUYFVPML61Flexible stnl. steel XUYFVERTD61 XUYFVERTC61 XUYFVPTD61 XUYFVPTC61 XUYFVPTL6110Other versions: please consult our Customer Care Centre.1/41


<strong>OsiSense</strong> XCCOpto-electronic rotary encodersIncremental12345678910Diameter of housing (mm) Ø 40 Ø 40 Ø 58 Ø 58 Ø 58 Ø 90ParametrableShaft Ø (mm) Ø 6 Ø 6 Ø 6 Ø 10 Ø 14 (1) Ø 12Type of shaft (2) solid shaft through shaft solid shaft solid shaft through shaft solid shaftMaximum rotational speed (rpm) 9000 9000 9000 9000 6000 6000Maximum frequency (kHz) 100 100 300 300 300 100Maximum load (daN) 2 2 10 10 5 20Torque (N.cm) 0.2 0.25 0.4 0.4 0.6 1Product certification CE CE CE CE CE CETemperature range (°C) - 20…+ 80 - 20…+ 80 - 30…+ 100 - 30…+ 100 - 30…+ 70 - 20…+ 80Degree of protection (conforming to IEC 60529) IP 54 IP 52 IP 65 / IP 67 (3) IP 65 / IP 67 (3) IP 65 IP 66Supply voltage 5 V, RS 422 4.5…5.5 V 4.5…5.5 V 4.75…30 V 4.75…30 V 4.75…30 V 4.5…5.5 VPush-pull 11…30 V 11…30 V 5…30 V 5…30 V 5…30 V 11…30 VConnection Pre-cabled (2 m), radial M23 male connector, radialResolution (Points) Output stage100 5 V, RS 422 XCC1406PR01R XCC1406TR01R XCC1506PS01X XCC1510PS01X – XCC1912PS01RNPush-pull XCC1406PR01K XCC1406TR01K XCC1506PS01Y XCC1510PS01Y – XCC1912PS01KN360 5 V, RS 422 XCC1406PR03R XCC1406TR03R XCC1506PS03X XCC1510PS03X – XCC1912PS03RNPush-pull XCC1406PR03K XCC1406TR03K XCC1506PS03Y XCC1510PS03Y – XCC1912PS03KN500 5 V, RS 422 XCC1406PR05R XCC1406TR05R XCC1506PS05X XCC1510PS05X – XCC1912PS05RNPush-pull XCC1406PR05K XCC1406TR05K XCC1506PS05Y XCC1510PS05Y – XCC1912PS05KN1000 5 V, RS 422 XCC1406PR10R XCC1406TR10R XCC1506PS10X XCC1510PS10X – XCC1912PS10RNPush-pull XCC1406PR10K XCC1406TR10K XCC1506PS10Y XCC1510PS10Y – XCC1912PS10KN1024 5 V, RS 422 XCC1406PR11R XCC1406TR11R XCC1506PS11X XCC1510PS11X – XCC1912PS11RNPush-pull XCC1406PR11K XCC1406TR11K XCC1506PS11Y XCC1510PS11Y – XCC1912PS11KN2500 5 V, RS 422 – – XCC1506PS25X XCC1510PS25X – XCC1912PS25RNPush-pull – – XCC1506PS25Y XCC1510PS25Y – XCC1912PS25KN3600 5 V, RS 422 – – – – – XCC1912PS36RNPush-pull – – – – – XCC1912PS36KN256…4096 5 V, RS 422 – – – – XCC1514TSM02X –Push-pull – – – – XCC1514TSM02Y –5000 5 V, RS 422 – – XCC1506PS50X XCC1510PS50X – XCC1912PS50RNPush-pull – – XCC1506PS50Y XCC1510PS50Y – XCC1912PS50KN360…5760 5 V, RS 422 – – – – XCC1514TSM03X –Push-pull – – – – XCC1514TSM03Y –500…8000 5 V, RS 422 – – – – XCC1514TSM05X –Push-pull – – – – XCC1514TSM05Y –10 000 5 V, RS 422 – – – – – XCC1912PS00RNPush-pull – – – – – XCC1912PS00KN1024…16 384 5 V, RS 422 – – – – XCC1514TSM11X –Push-pull – – – – XCC1514TSM11Y –5000…80 000 5 V, RS 422 – – – – XCC1514TSM50X –Push-pull – – – – XCC1514TSM50Y –AccessoriesShaft couplingsFixing bracketswith spring Bore diameter Bore diameter Reference Plain bracket for Ø 58 mm XCCRE5SN(encoder side) (machine side) for Ø 90 mm XCCRE9SN6 mm 6 mm XCCRAR06066 mm 8 mm XCCRAR06086 mm 10 mm XCCRAR061010 mm 10 mm XCCRAR1010 Bracket with play compensator for Ø 58 mm XCCRE5RN10 mm 12 mm XCCRAR1012 for Ø 90 mm XCCRE9RNelastic 6 mm 6 mm XCCRAE06061/44Other versions: please consult our Customer Care Centre.


Absolute Absolute Communicating- single turn - multiturn multiturn absolute1Diameter of housing (mm) Ø 58 Ø 90 Ø 58 Ø 90 Ø 58CANopenØ 58PROFIBUS-DPShaft Ø (mm) Ø 6 Ø 12 Ø 10 Ø 12 Ø 10 Ø 10Type of shaft (2) solid shaft solid shaft solid shaft solid shaft solid shaft (4) solid shaft (4)Maximum rotational speed (rpm) 9000 6000 6000 6000 6000 6000Maximum frequency (kHz) 100 100 (1000 SSI) 100 (500 SSI) 100 (500 SSI) 800 800Maximum load (daN) 10 20 10 20 11 11Torque (N.cm) 0.4 1 0.4 1 0.3 0.3Product certification CE CE CE CE CE CETemperature range (°C) - 20…+ 90 - 20…+ 85 - 20…+ 85 - 20…+ 85 - 40…+ 85 - 40…+ 85Degree of protection (conforming to IEC 60529) IP 65 IP 66 IP 65 / IP 67 (3) IP 66 IP 64 IP 64Supply voltage11…30 V23Connection M23 male connector, radial 2 x M12 + 1 x Pg 9 3 x Pg 9Resolution Output stage Code… 8192 points Push-pull Binary XCC2506PS81KB XCC2912PS81KBN – – – –Gray XCC2506PS81KGN XCC2912PS81KGN – – – –SSI, 13-bit Binary XCC2506PS81SBN XCC2912PS81SBN – – – –Gray XCC2506PS81SGN XCC2912PS81SGN – – – –4096 points /8192 turns SSI, 25-bit (5) Gray – – XCC3510PS48SGN – – –8192 points / SSI, 25-bit (5) Binary XCC3510PS84SBN XCC3912PS84SBN4096 turnsGray – – XCC3510PS84SGN XCC3912PS84SGN8192 points /4096 turnsCANopen,25-bit Binary – – XCC3510PS84CBN –PROFIBUS-DP,25-bit Binary – – – – – XCC3510PV84FBN(1) Anti-rotation device included with through shaft version encoders. To achieve Ø 6, 8, 10 or 12 mm through shafts, use the reduction collars.(2) All versions are also available with through shaft and anti-rotation device.(3) IP 67 with sealed collar XCCRB3.(4) Versions available with hollow shaft and anti-rotation device.(5) “Parallel” outputs possible for multiturn absolute encoders using derserialisation jumper cables XCCRM23SUB37pp.45678Reduction collarsFor Ø 58 mm incremental encoders with through shaftØ 14 to Ø 6 mm XCCR158RDA06Ø 14 to Ø 8 mm XCCR158RDA08Ø 14 to Ø 10 mm XCCR158RDA10Ø 14 to Ø 12 mm XCCR158RDA12IP 67 sealed collarFor encoders XCC1510, 2510, 3510Ø 58 mmXCCRB3Pre-wired connectors and jumper cablesPre-wired M23 female connectors (cable length 5 m)8-wire for SSI encoders10-wire for incremental encoders16-wire for parallel single turn absolute encodersDeserialisation jumper cables (M23 F - SUB-D37 M) (L = 0.5 m)SSI Gray - // Gray PNPSSI binary - // binary NPNXCCPM23122L5XCCPM23121L5XCCPM23161L5XCCRM23SUB37PGXCCRM23SUB37PB910Other versions: please consult our Customer Care Centre.1/45


<strong>OsiSense</strong> XGRadio frequency identification13.56 MHz RFID123Presentation<strong>OsiSense</strong> XG is open to the majority of ISO 18000-3, ISO 15693 and ISO 14443 electronic tags.<strong>OsiSense</strong> XG integrates Modbus RTU, Uni-Telway, Modbus TCP/IP (using Ethernet box XGSZ33ETH) andProfibus DP (with box XGSZ33PDP) protocols.The <strong>OsiSense</strong> XG RFID offer comprises:- 2 models of 13.56 MHz compact stations (read/write)- 6 models of 13.56 MHz electronic tags- 1 portable RFID diagnostics terminal- 3 models of network connection boxes plus connection and mounting accessories.Setting-up<strong>OsiSense</strong> XG compact stations are simple to set-up:- Integrated RFID and network functions- No programming- Automatic detection of the RFID electronic tags (read or write)- Automatic setting of the communication parameters (speed, format, parity, protocol, etc.)- Configuration of the network address (1 to 15) using badge included with the station- Low sensitivity to metal environments.Installation<strong>OsiSense</strong> XG stations easily integrate in flexible manufacturing production lines:- quick connection using M12 connector- screw fixing or clip-on mounting.4567Compact stations, 13.56 MHz C format D formatDimensions (mm), W x H x D 40 x 40 x 15 80 x 80 x 26Nominal sensing distance depending on tag (mm) 18 to 70 20 to 100Type of associated tagISO 15693 and ISO 14443 standard tags. Automatic detection of the type of tag.Display1 dual colour LED for the communication network, 1 dual colour LED for the RFID communicationConformity to standardsCE, EN 301489-1, EN 301489-3, ETS 300330-1 and ETS 300330-2, FCC part 15 - ULDegree of protection conforming to IEC 60529 IP 67Serial link Type RS 485ProtocolModbus and Uni-TelwaySpeed (Bauds)9600…115 200 (automatic detection)Ambient air temperature (°C) For operation: - 25…+ 70 °C, for storage: - 40…+ 85 °CNominal supply voltage24 VDC PELV (Protective Extra Low Voltage)ConnectionM12, 5-pin male, shielded connector on flying lead. Only for connection to the communication network and the supplyReferences XGCS4901201 XGCS89012018910Electronic tags C format ISO badge(1)Disc E format CylindricalDimensions (mm), W x H x D 40 x 40 x 15 54 x 85.5 x 0.8 Ø 30 x 3 26 x 26 x 13 M18 x 1 x 12Type of memoryEEPROMMemory capacity (bytes) 3 408 13 632 256 112 256 256Nominal sensing distance (mm) With station XGCS49p 33 30 70 48 40 18(Read/Write) With station XGCS89p 48 40 100 65 55 20Time (ms) Read 9.25 + 0.375 x n (2) 16.25 + 0.375 x n (2) 12 + 0.825 x n (2)Write 13 + 0.8 x n (2) 20 + 0.8 x n (2) 20 + 11.8 x n (2) 12 + 5.6 x n (2) 20 + 11.8 x n (2) 19 + 4.1 x n (2)Degree of protection conforming to IEC 60529 IP 68 IP 65 IP 68Standard supported ISO 14443 ISO 15693Mounting on metal support Yes No Yes NoReferences XGHB444345 XGHB445345 XGHB90E340 XGHB320345 XGHB221346 XGHB211345(1) Customised versions on request. (2) n = number of 16-bit words.1/46Other versions: please consult our Customer Care Centre.


New1Connection boxes Ethernet box Profibus box Tap-off boxDimensions (mm), W x H x D 130 x 80 x 51 130 x 80 x 51Protocols Modbus TCP/IP Profibus DP Modbus, Uni-TelwaySupply voltage24 VDC PELV. M12, 4-pin male, A coding, connectorConformity to standards CE - UL CE CE - ULStation connectionM12, 5-pin female, A coding, connectorDegree of protection conforming to IEC 60529 IP 65References XGSZ33ETH XGSZ33PDP TCSAMT31FP234TerminalPortable 13.56 MHz RFID diagnostics terminalDimensions (mm), W x H x P 120 x 250 x 62FunctionRead/Write operations on electronic tags and diagnostics on compact stationsOperating system Microsoft® Windows CE.NET Professional® version 4.2Conformity to standards CE, FCC class A, Part 15225Display72 x 54 mm colour touchscreen; QVGA TFT, 320 x 240 pixels resolutionDegree of protection conforming to IEC 60529 IP 65Memory RAM 64 Mb SDRAMStorageInternal Compact Flash (512 Mb standard, expandable to 128 Mb) + Slot for Compact Flash cardReferenceXGSTP401 (Battery, battery charger, carrying case and 3 styluses included with terminal)567Connection accessoriesfor Modbus network for Profibus for Ethernet Pre-wired connector “T” connectorDescription Modbus connectingcable M12 connectorsMale / FemalePre-wired connectorM12 male / BarewiresModbus connectingcable M12 female /Mini-DIN 8Profibus connectingcables M12 connectorsMale / FemaleEthernet ConneXiumconnecting cableM12 male / RJ 45Pre-wiredsupply connectorM12 femaleNetwork M12“T” connector1 male / 2 femaleApplication RS485 connectionbetween a compact stationConnection betweena Modbus box and aConnection betweena Modbus box andConnection betweenProfibus box andConnection betweenan Ethernet box and24 VDC supply toconnection boxesFor RS 485 networkand a Modbus box or Modbus / Uni-Telway a PLCProfibus network the Ethernet networkbetween 2 Modbus boxes networkL = 2 m TCSMCN1M1F2 TCSMCN1F2 TCSMCN1F9M2P FTXDP1220 TCSECL1M3M3S2 (3) XGSZ09L2L = 5 m TCSMCN1M1F5 TCSMCN1F5 – FTXDP1250 TCSECL1M3M5S2 XGSZ09L5TCSCTN011M11F(3) L = 3 mField expander RS232/RS485 converter Technical documentationTo be associated with a compact station XGCS4901201 for conveyingand handling applicationsNewFor connecting a PC toan <strong>OsiSense</strong> XG station<strong>OsiSense</strong> XG compactstations guide891050 x 400 mmXGFEC540250 x 250 mmXGFEC2525 XGSZ24 DIA4ED3051001Other versions: please consult our Customer Care Centre.1/47


HarmonyHarmony control and signalling products arecharacterised by their extreme ruggedness,ergonomic design and ease of use, all of whichhave contributed to their successful applicationworldwide. The unrivalled depth of the Harmonyrange provides solutions to meet the diverseneeds of your applications.From the humble pushbutton to the mostcomplex operator dialogue terminal,Schneider Electric is the world’s leadingsupplier of human-machine interfacecomponents. Open-ended and highlyinnovative, the Harmony and Magelisranges are synonymous with seamlessintegration and effective configurationsolutions in dialogue applications.HMI MagelisA comprehensive, rugged, open-endedinterface and industrial PC offer to meetyour requirements in a wide variety ofapplications. With its extensive capabilities,Magelis ensures the dependability of yourinstallations.


Operator dialogThis document is a selection ofthe top selling products.1Control and signalling unitsHuman/Machine InterfacesPushbuttons, switches, pilot lights & control stationsØ 16, plastic bezel, Harmony XB6 .............................................................................. 2/2 to 2/4Ø 8 & 12, pilot lights, Harmony XVL ..................................................................................... 2/5Ø 22, metal bezel, Harmony XB4 / Control stations Harmony XAP ........................... 2/6 to 2/9Ø 22, plastic bezel, Harmony XB5 / Control stations Harmony XAL ..................... 2/10 to 2/13Ø 22, plastic bezel - Monolithic, Harmony XB7 ....................................................... 2/14 to 2/15Ø 30, metal and plastic bezel, Harmony 9001K, 9001SK ....................................... 2/16 to 2/19Cam switchesHarmony K series ................................................................................................... 2/20 to 2/21Signalling solutionsØ 40, 60, 100 mm monolithic tower lights, Harmony XVC .................................................. 2/22Ø 45 mm monolithic beacons and tower lights, accessories, Harmony XVDLS / XVC ....... 2/23Ø 70 mm modular tower lights (IP 66), Harmony XVB ........................................................ 2/24Ø 70 mm modular tower lights (up to IP 54), Harmony XVE ............................................... 2/25Ø 45, 50 mm modular tower lights (up to IP 54), Harmony XVM / XVP .............................. 2/26Modular tower lights accessories, Harmony XV .................................................................. 2/27Ø 84, 106, 120, 130 mm rotating mirror beacons, Harmony XVR ....................................... 2/28Accessories for rotating mirror beacons, Harmony XVR ...................................................... 2/29Electronic alarms and multisound sirens, Harmony XVS .................................................... 2/29Components for hoisting applicationsPendant control stations, Harmony XAC ................................................................. 2/30 to 2/31Display units, terminals, Industrial PCsSmall Panels, Magelis STO/STU, XBT N / R / RT .................................................... 2/32 to 2/34Advanced Panels, Magelis XBT GT, GK, GTW, GH ................................................ 2/35 to 2/39HMI Controllers, Compact Magelis XBT GC ........................................................................ 2/40PC Panels, Magelis Smart, Magelis Compact iPC ............................................................ 2/41Embedded Box and PC Box, Magelis Smart BOX, Compact BOX & Flex PC BOX .......... 2/42Front Panels, for Flex PC BOX ............................................................................................. 2/43Industrial Display, Magelis iDisplay ..................................................................................... 2/43Configuration softwareFor Magelis XBT N / R / RT,Vijeo Designer Lite ....................................................................................................... 2/44For Magelis STO/STU, XBT GT, GK, GTW, GH, Magelis Smart, Compact iPC, PC BOX,Vijeo Designer .............................................................................................................. 2/45Dialog operator for Explosive atmospheresSee Chapter 10 “Explosive atmospheres”23456789102/1


HarmonyXB6Pushbuttons, switches and pilot lights Ø 16with plastic bezelContact functions and light functionswith integral LED1(1):VoltageLetter (p)12…24 V AC/DC (15 mA) B48…120 V AC (25 mA) G230…240 V AC (25 mA) MIlluminated pushbuttons= + +23Type of headFlush pushShape of head rectangular (2)Degree of protectionIP 65 / Nema 4, 4X, 13 / Class II+ 0.2Mounting (mm) panel cut-out Ø 16.2 0mounting centres24 x 18 with rectangular head, 18 x 18 with square or circular headDimensions (mm) W x H x D (below head) 24 x 18 x 50 with rectangular head, 18 x 18 x 50 with square or circular headConnection (3)Tags for 2.8 x 0.5 Faston connectors or for solderingType of pushSpring returnComplete products Products for user assembly12 … 24 V AC/DC456References white NO XB6DW1B1B ZB6Ep1B (1) ZB6Z1B ZB6DW1NO + NC XB6DW1B5B ZB6Ep1B (1) ZB6Z5B ZB6DW1green NO XB6DW3B1B ZB6Ep3B (1) ZB6Z1B ZB6DW3NO + NC XB6DW3B5B ZB6Ep3B (1) ZB6Z5B ZB6DW3red NC XB6DW4B2B ZB6Ep4B (1) ZB6Z2B ZB6DW4NO + NC XB6DW4B5B ZB6Ep4B (1) ZB6Z5B ZB6DW4yellow NO – ZB6Ep5B (1) ZB6Z1B ZB6DW5NO + NC XB6DW5B5B ZB6Ep5B (1) ZB6Z5B ZB6DW5Type of pushLatchingReferences white NO – ZB6Ep1B (1) ZB6Z1B ZB6DF1NO + NC XB6DF1B5B ZB6Ep1B (1) ZB6Z5B ZB6DF1green NO XB6DF3B1B ZB6Ep3B (1) ZB6Z1B ZB6DF3NO + NC XB6DF3B5B ZB6Ep3B (1) ZB6Z5B ZB6DF3red NC XB6DF4B2B ZB6Ep4B (1) ZB6Z2B ZB6DF4NO + NC XB6DF4B5B ZB6Ep4B (1) ZB6Z5B ZB6DF4yellow NO – ZB6Ep5B (1) ZB6Z1B ZB6DF5NO + NC – ZB6Ep5B (1) ZB6Z5B ZB6DF578910= +Pilot lightsType of headSmooth lens capShape of head rectangular (2)Complete products Products for user assembly12 … 24 V AC/DCReferences white XB6DV1BB ZB6Ep1B (1) ZB6DV1green XB6DV3BB ZB6Ep3B (1) ZB6DV3red XB6DV4BB ZB6Ep4B (1) ZB6DV4yellow XB6DV5BB ZB6Ep5B (1) ZB6DV5blue – ZB6Ep6B (1) ZB6DV6(1) Basic reference, to be completed by the letter B, G or M indicating the required voltage. See voltage table above.(2) For products with a square head, replace the letter D in the reference by the letter C (XB6DW1B1B becomes XB6CW1B1B).For products with a circular head, replace the letter D in the reference by the letter A (XB6DW1B1B becomes XB6AW1B1B).(3) Alternative connection: 1 x 0.5 pins for printed circuit boards.2/2Other versions: please consult our Customer Care Centre.


Contact functionsPushbuttons= +Type of headFlush pushShape of head rectangular (1)Degree of protectionIP 65 / Nema 4, 4X, 13 / Class II+ 0.2Mounting (mm) panel cut-out Ø 16.2 0mounting centres24 x 18 with rectangular head, 18 x 18 with square or circular headDimensions (mm) W x H x D (below head) 24 x 18 x 50 with rectangular head, 18 x 18 x 50 with square or circular headConnection (2)Tags for 2.8 x 0.5 Faston connectors or for solderingType of pushSpring returnComplete products Products for user assembly123References white NO XB6DA11B ZB6Z1B ZB6DA1NO + NC XB6DA15B ZB6Z5B ZB6DA1black NO – ZB6Z1B ZB6DA2NO + NC XB6DA25B ZB6Z5B ZB6DA2green NO XB6DA31B ZB6Z2B ZB6DA3NO + NC XB6DA35B ZB6Z5B ZB6DA3red NO – ZB6Z1B ZB6DA4NO + NC XB6DA45B ZB6Z5B ZB6DA4(1) For products with a square head, replace the letter D in the reference by the letter C (XB6DA11B becomes XB6CA11B).For products with a circular head, replace the letter D in the reference by the letter A (XB6DA11B becomes XB6AA11B).(2) Alternative connection: 1 x 0.5 pins for printed circuit boards.456Ø 30 mushroom head Emergency stop pushbuttons (3)Type of head Trigger action (EN/ISO 13850)Shape of headcylindricalType of pushTurn to releaseComplete productsProducts for user assemblyReferences red 2 NC + 1 NO XB6AS8349B ZB6E2B ZB6Z5B ZB6AS834Type of push Key release, Ronis 200= + +References red 2 NC + 1 NO XB6AS9349B ZB6E2B ZB6Z5B ZB6AS934(3) Emergency stop trigger action and mechanical latching pushbuttons conform to standards EN/IEC 60204-1 and EN/ISO 13850: to Machinery Directive 2006/42/EC and to standardEN/IEC 60947-5-5. Please consult your Regional Sales Office for a full explanation of these standards and directives.78910Other versions: please consult our Customer Care Centre.2/3


HarmonyXB6Pushbuttons, switches and pilot lights Ø 16with plastic bezelContact functions and light functionswith integral LED1= +Selector switches and key switches23Type of headBlack handleShape of head rectangular (2)Degree of protectionIP 66 / Nema 4, 4X, 13 / Class II+ 0.2Mounting (mm) panel cut-out Ø 16.2 0mounting centres24 x 18 with rectangular head, 18 x 18 with square or circular headDimensions (mm) W x H x D (below head) 24 x 18 x 50 with rectangular head, 18 x 18 x 50 with square or circular headConnection (3)Tags for 2.8 x 0.5 Faston connectors or for solderingType of operatorBlack handleComplete productsProducts for user assembly4567Number and type of positions 2 positions 60° 2 positions 60°2 positions45°stay put stay put spring return to centreReferences NO XB6DD221B ZB6Z1B ZB6DD22 ZB6Z1B ZB6DD24NO + NC XB6DD225B ZB6Z5B ZB6DD22 ZB6Z5B ZB6DD24Number and type of positions 3 positions 60° 60° 3 positions 60° 60°3 positions 45° 45°stay put stay put spring return to centreReferences NO XB6DD235B ZB6Z5B ZB6DD23 ZB6Z5B ZB6DD25= +Type of operator Ronis key, n° 200Complete productsProducts for user assemblyNumber and type of positions 2 positions70°2 positions70°2 positions45°stay put stay put spring return to centreReferences NO + NC XB6DGC5B ZB6Z5B ZB6DGC ZB6Z5B ZB6DGBNumber and type of positions 3 positions70° 70°3 positions70° 70°3 positions45° 45°stay put stay put spring return to centreReferences NO + NC XB6DGH5B ZB6Z5B ZB6DGH ZB6Z5B ZB6DGS8(1):VoltageLetter (p)12…24 V AC/DC (15 mA) B48…120 V AC (25 mA) G230…240 V AC (25 mA) MIlluminated selector switches= + +9Type of operatorProducts for user assemblyColoured handle10Number and type of positions 2 positions60°3 positions60° 60°stay putstay putReferences white NO + NC ZB6Ep1B (1) ZB6Z5B ZB6DD02 ZB6DD03 ZB6YK1green NO + NC ZB6Ep3B (1) ZB6Z5B ZB6DD02 ZB6DD03 ZB6YK3red NO + NC ZB6Ep4B (1) ZB6Z5B ZB6DD02 ZB6DD03 ZB6YK4(1) Basic reference, to be completed by the letter B, G or M indicating the required voltage. See voltage table above.(2) For products with a square head, replace the letter D in the reference by the letter C (XB6DD221B becomes XB6CD221B).For products with a circular head, replace the letter D in the reference by the letter A (XB6DD221B becomes XB6AD221B).(3) Alternative connection: 1 x 0.5 pins for printed circuit boards.Other versions: please consult our Customer Care Centre.2/4


LED pilot lights Ø 8 and 12(1):VoltageNumber (p)5 V (25 mA) 112 V (18 mA) 224 V (18 mA) 348 V (10 mA) 41LED pilot lights With black bezel With integral lens capType of head Protruding LED, Ø 8 mm Covered LED, Ø 8 mm Covered LED, Ø 12 mmDegree of protection IP 40, IP 65 with seal (2)Mounting (mm) panel cut-out Ø 8.2 mm Ø 8.2 mm Ø 12.2 mmmounting centres 12.5 x 12.5 mm 10.5 x 10.5 mm 16.5 x 16.5 mmDimensions (mm) Ø x Depth (below head) Ø 12 x 32 Ø 10 x 34 Ø 16 x 45Connection Tags (3) Tags (3) Threaded connectorsReferences (1) green XVLA1p3 XVLA2p3 XVLA3p3red XVLA1p4 XVLA2p4 XVLA3p4yellow XVLA1p5 XVLA2p5 XVLA3p5Tightening key For Ø 8 mm pilot lights For Ø 12 mm pilot lightsReferences XVLX08 XVLX12(1) Basic reference, to be completed by the number 1, 2, 3 or 4 indicating the required voltage. See voltage table above.(2) For an IP 65 degree of protection, include the seals: XVLZ911 for pilot lights XVLA1pp and XVLA2pp; XVLZ912 for pilot lights XVLA3pp.(3) Tags for 2.8 x 0.5 Faston connectors or for soldering.234Sub-assemblies & accessories for Ø 16plastic bezel control and signalling units5Sub-assembliesBodies for pushbuttons andselector switchesBodies for pilot lightsRated operational characteristics, AC-15: Ue = 240 V and Ie = 1.5 A or Ue = 120 V and Ie = 3 AConsumptionPositive operation of contacts conforming to IEC/EN 60947-5-1: NC contacts with positive opening operation, 15 mA 12…24 V AC/DCpositive opening force 20 N 25 mA 48…120 V AC25 mA 230…240 V ACType of Fixing collar Contacts Pilot light 12 … 24 V 48 … 120 V 230 … 240 Vcontact + contacts bodiesReferences NO ZB6Z1B ZB6E1B White ZB6EB1B ZB6EG1B ZB6EM1BNC ZB6Z2B ZB6E2B Green ZB6EB3B ZB6EG3B ZB6EM3B2 NO ZB6Z3B – Red ZB6EB4B ZB6EG4B ZB6EM4B2 NC ZB6Z4B – Yellow ZB6EB5B ZB6EG5B ZB6EM5BNO + NC ZB6Z5B – Blue ZB6EB6B ZB6EG6B ZB6EM6BAccessoriesLegend holders 24 x 28 mm (8 x 21 mm legend) 24 x 36 mm (16 x 21 mm legend)Blank legend Background colour without legend yellow or white black or red without legend yellow or white black or redReferences (10)* ZB6YD20 ZB6YD21 ZB6YD22 ZB6YD30 ZB6YD31 ZB6YD32Blank legends for legend holders 8 x 21 mm (24 x 28 mm legend holder) 16 x 21 mm (24 x 36 mm legend holder)Background colour – yellow or white black or red – yellow or white black or redReferences (20)* – ZB6Y1001 ZB6Y2001 – ZB6Y4001 ZB6Y3001Ø 45 mm yellow legend for mushroom head Emergency stop pushbuttonMarking Blank, for engraving EMERGENCY STOP ARRET D’URGENCEReferences ZB6Y7001 ZB6Y7330 ZB6Y7130Body/fixing collar Plate Tightening tool Dismantling toolanti-rotation and slackening, for fixing nut for removal of contact blocksReferences ZB6Y009 (10)* ZB6Y003 (10)* ZB6Y905 (2)* ZB6Y018 (5)*Protective shutter for pushbuttons and switches Connector Blanking plugfor rectangular heads for circular and square heads Faston, female IP 65References ZB6YD001 ZB6YA001 ZB6Y004 (100)* ZB6Y005 (10)** sold in lots ofOther versions: please consult our Customer Care Centre.2/5678910


HarmonyXB4Pushbuttons, switches and pilot lights Ø 22with metal bezelContact functions1= +Pushbuttons, spring return23Type of headChromium plated circular bezelDegree of protectionIP 66 / Nema 4X, 13 / Class IMounting (mm) panel cut-out+ 0.4Ø 22.5 (22.4 0 recommended)mounting centres30 (horizontal) x 40 (vertical)Depth (mm) below head 43Connection (1)Screw clamp terminalsType of push Flush Flush, bootedUnmarked Products Complete For user assembly Complete For user assembly45678References black NO XB4BA21 ZB4BZ101 ZB4BA2 XB4BP21 ZB4BZ101 ZB4BP2green NO XB4BA31 ZB4BZ101 ZB4BA3 XB4BP31 ZB4BZ101 ZB4BP3red NC XB4BA42 ZB4BZ102 ZB4BA4 XB4BP42 ZB4BZ102 ZB4BP4yellow NO XB4BA51 ZB4BZ101 ZB4BA5 XB4BP51 ZB4BZ101 ZB4BP5blue NO XB4BA61 ZB4BZ101 ZB4BA6 XB4BP61 ZB4BZ101 ZB4BP6Type of pushFlushWith international marking Products Complete For user assemblyReferences green NO XB4BA3311 ZB4BZ101 ZB4BA331 – – –red NC XB4BA4322 ZB4BZ102 ZB4BA432 – – –white NO XB4BA3341 ZB4BZ101 ZB4BA334 – – –black NO XB4BA3351 ZB4BZ101 ZB4BA335 _ _ _Type of push Projecting Mushroom head, Ø 40 mmUnmarked Products Complete For user assembly Complete For user assemblyReferences black NO – – – XB4BC21 ZB4BZ101 ZB4BC2red NC XB4BL42 ZB4BZ102 ZB4BL4 – – –Type of push Double-headed pushbuttons Triple-headed pushbuttonsDegree of protection IP 66 - IP 69K IP 66 - IP 69KWith international marking Products Complete For user assembly Complete For user assembly(A)(B)References (A) NO + NC XB4BL73415 ZB4BZ105 ZB4BL7341 – – –(B) NO + NC + NO – – – XB4BA711237 ZB4BZ103 + ZB4BA71123ZBE102(1) Alternative connections: plug-in connector,Faston connectors (6.35 and 2 x 2.8).= ++9Ø 40 mm mushroom head Emergency stop pushbuttons (2)Trigger action (EN/ISO 13850)Type of pushPush-pull NO + NCUnmarked Products Complete For user assembly10References red NO + NC XB4BT845 ZB4BZ105 ZB4BT84Type of pushTurn to release NO + NCReferences red NO + NC XB4BS8445 ZB4BZ105 ZB4BS844Type of pushKey release NO + NCReferences red NO + NC XB4BS9445 ZB4BZ105 ZB4BS944(2) Emergency stop trigger action and mechanical latching pushbuttons conform to standards EN/IEC 60204-1 and EN/ISO 13850, to Machinery Directive 2006/42/EC and to standardEN/IEC 60947-5-5. Please consult your Regional Sales Office for a full explanation of these standards and directives.2/6Other versions: please consult our Customer Care Centre.


Contact functions= +1Selector switches and key switchesType of headChromium plated circular bezelDegree of protectionIP 66 / Nema 4X, 13 / Class IMounting (mm) panel cut-out+ 0.4Ø 22.5 (22.4 0 recommended)mounting centres30 (horizontal) x 40 (vertical)Depth (mm) below head 43Connection (1)Screw clamp terminalsType of operatorHandleProducts Complete For user assembly Complete For user assembly23Number and type of positions 2 positions 2 positions 2 positions 2 positionsstay put stay put spring return to left spring return to leftReferences black NO XB4BD21 ZB4BZ101 ZB4BD2 XB4BD41 ZB4BZ101 ZB4BD4Number and type of positions 3 positions 3 positions 3 positions 3 positionsstay put stay put spring return to centre spring return to centreReferences black NO + NO XB4BD33 ZB4BZ103 ZB4BD3 XB4BD53 ZB4BZ103 ZB4BD545= +6Type of operator Key, n° 455Products Complete For user assembly Complete For user assemblyNumber and type of positions (2) 2 positions 2 positions 2 positions 2 positionsstay put stay put stay put stay putReferences black NO XB4BG21 ZB4BZ101 ZB4BG2 XB4BG41 ZB4BZ101 ZB4BG4Number and type of positions 2 positions 2 positions 3 positions 3 positionsspring return to left spring return to left stay put stay putReferencesblack NO XB4BG61 ZB4BZ101 ZB4BG6 – – –black NO + NO – – – XB4BG33 ZB4BZ103 ZB4BG378910Other versions: please consult our Customer Care Centre.2/7


HarmonyXB4Pushbuttons, switches and pilot lights Ø 22with metal bezelLight functions1= +Pilot lights23Type of headCircular bezelSmooth lens capDegree of protectionIP 66 / Nema 4X, 13 / Class IMounting (mm) panel cut-out+ 0.4Ø 22.5 (22.4 0 recommended)mounting centres30 (horizontal) x 40 (vertical)Depth below head 43Connection (1)Screw clamp terminalsLight source Integral LED Direct supply for BA 9s bulb (not included)Products Complete Complete For user assembly456Supply voltage 24 V AC/DC 110…120 V AC 230…240 V AC 250 V max., 2.4 W max.References white XB4BVB1 XB4BVG1 XB4BVM1 XB4BV61 ZB4BV6 ZB4BV01green XB4BVB3 XB4BVG3 XB4BVM3 XB4BV63 ZB4BV6 ZB4BV03red XB4BVB4 XB4BVG4 XB4BVM4 XB4BV64 ZB4BV6 ZB4BV04yellow XB4BVB5 XB4BVG5 XB4BVM5 XB4BV65 ZB4BV6 ZB4BV05blue XB4BVB6 XB4BVG6 XB4BVM6 – – –= +Illuminated pushbuttons and selector switchesTypeFlush push, spring return, illuminated pushbuttonsLight source Integral LED Direct supply for BA 9s bulb (not included)Products Complete Complete For user assembly78Supply voltage 24 V AC/DC 110…120 V AC 230…240 V AC 250 V max., 2.4 W max.References white NO + NC XB4BW31B5 XB4BW31G5 XB4BW31M5 XB4BW3165 ZB4BW065 ZB4BW31green NO + NC XB4BW33B5 XB4BW33G5 XB4BW33M5 XB4BW3365 ZB4BW065 ZB4BW33red NO + NC XB4BW34B5 XB4BW34G5 XB4BW34M5 XB4BW3465 ZB4BW065 ZB4BW34orange NO + NC XB4BW35B5 XB4BW35G5 XB4BW35M5 XB4BW3565 ZB4BW065 ZB4BW35blue NO + NC XB4BW36B5 XB4BW36G5 XB4BW36M5 – – –910Type Double-headed pushbuttons with LED pilot light Illuminated selector switches(1 flush green push, 1 projecting red push) (2 position stay put)Degree of protection IP 66 - IP 69K IP 66Light source Integral LED Integral LEDProducts Complete CompleteSupply voltage 24 V AC/DC 110…120 V AC 230…240 V AC 24 V AC/DC 110…120 V AC 230…240 V ACReferences green NO + NC – – – XB4BK123B5 XB4BK123G5 XB4BK123M5red NO + NC – – – XB4BK124B5 XB4BK124G5 XB4BK124M5orange NO + NC – – – XB4BK125B5 XB4BK125G5 XB4BK125M5White NO + NC XB4BW73731B5 XB4BW73731G5 XB4BW73731M5 – – –(1) Alternative connections: plug-in connector, Faston connectors (6.35 and 2 x 2.8), spring clamp terminal.2/8Other versions: please consult our Customer Care Centre.


Separate components and accessories1Electrical blocks (1) (2)Single contact blocks Light blocks with integral LED Light block, direct supplyRated operational characteristicsAC-15, 240 V - 3 AConsumption18 mA 24 V AC/DCPositive operation of contacts NC contacts with positive14 mA 120 V ACconforming to IEC/EN 60947-5-1 opening operation14 mA 240 V ACScrew clamp Spring clamp To combine with heads for integral LEDFor BA 9s bulb (not included)terminal terminal24 V AC/DC 110…120 V AC 230…240 V AC 250 V max., 2.4 W max.References (5)* NO ZBE101 ZBE1015 white ZBVB1 ZBVG1 ZBVM1 ZBV6NC ZBE102 ZBE1025 green ZBVB3 ZBVG3 ZBVM3 Colour provided by lensred ZBVB4 ZBVG4 ZBVM4orange ZBVB5 ZBVG5 ZBVM5blue ZBVB6 ZBVG6 ZBVM6234Diecast metal enclosures(Zinc alloy, usable depth 49 mm) 1 vertical row 2 vertical rowsNumber of cut-outs Front face dimensions 1 2 3 4 2 4 6References 80 x 80 mm XAPM1201 – – – XAPM1202 – –80 x 130 mm – XAPM2202 XAPM2203 – – XAPM2204 –80 x 175 mm – – XAPM3203 XAPM3204 – – XAPM3206567Accessories (2)Legend holders, 30 x 40 mm, for 8 x 27 mm legendsMarking Background colour: black or red white or yellowReferences (10)* Blank ZBY2101 ZBY4101International 0 (red background) ZBY2931 I ZBY2147 AUTO ZBY2115 STOP ZBY2304 –English OFF ZBY2312 ON ZBY2311 START ZBY2303 – –French ARRET (red b/grnd) ZBY2104 ARRET-MARCHE ZBY2166 MARCHE ZBY2103 – –German AUS ZBY2204 AUS-EIN ZBY2266 EIN ZBY2203 – –Spanish PARADA (red b/grnd) ZBY2404 PARADA-MARCHA ZBY2466 MARCHA ZBY2403 – –Legend holders, 30 x 50 mm, for 18 x 27 mm legendsBackground colour black or red white or yellowReferences (10)* Blank ZBY6101 ZBY6102Ø 60 mm legend for mushroom head Emergency stop pushbuttonBackground colouryellowMarking Blank EMERGENCY STOP ARRET D’URGENCE NOT HALT PARADA DE EMERGENCIAReferences ZBY9140 ZBY9330 ZBY9130 ZBY9230 ZBY9430(1) Alternative connections: plug-in connector, Faston connectors (6.35 and 2 x 2.8), spring clamp terminal.(2) Electrical blocks and accessories also for use with Harmony XB5plastic range* sold in lots of8910Other versions: please consult our Customer Care Centre.2/9


HarmonyXB5Pushbuttons, switches and pilot lights Ø 22with plastic bezelContact functions1= +Pushbuttons, spring return23Type of headCircular bezelDegree of protectionIP 66 / Nema 4X, 13 / Class IIMounting (mm) panel cut-out+ 0.4Ø 22.5 (22.4 0 recommended)mounting centres30 (horizontal) x 40 (vertical)Depth (mm) below head 43Connection (1)Screw clamp terminalsType of push Flush Flush, bootedUnmarked Products Complete For user assembly Complete For user assembly45678References black NO XB5AA21 ZB5AZ101 ZB5AA2 XB5AP21 ZB5AZ101 ZB5AP2green NO XB5AA31 ZB5AZ101 ZB5AA3 XB5AP31 ZB5AZ101 ZB5AP3red NC XB5AA42 ZB5AZ102 ZB5AA4 XB5AP42 ZB5AZ102 ZB5AP4yellow NO XB5AA51 ZB5AZ101 ZB5AA5 XB5AP51 ZB5AZ101 ZB5AP5blue NO XB5AA61 ZB5AZ101 ZB5AA6 XB5AP61 ZB5AZ101 ZB5AP6Type of pushType of push Double-headed pushbuttons Triple-headed pushbuttonsDegree of protection IP 66 - IP 69K IP 66 - IP 69KWith international marking Products Complete For user assemblyCompleteFlushWith international marking Products Complete For user assembly Complete For user assemblyReferences green NO XB5AA3311 ZB5AZ101 ZB5AA331 – – –red NC XB5AA4322 ZB5AZ102 ZB5AA432 – – –white NO XB5AA3341 ZB5AZ101 ZB5AA334 – – –black NO XB5AA3351 ZB5AZ101 ZB5AA335 – – –Type of push Projecting Mushroom head, Ø 40 mmUnmarked Products Complete For user assembly Complete For user assemblyReferences black NO – – – XB5AC21 ZB5AZ101 ZB5AC2red NC XB5AL42 ZB5AZ102 ZB5AL4 – – –(A)(B)For user assemblyReferences (A) NO + NC XB5AL73415 ZB5AZ105 ZB5AL7341 – – –(B) NO + NC + NO – – – XB5AA711237 ZB5AZ103 + ZB5AA71123ZBE102(1) Alternative connections: plug-in connector,Faston connectors (6.35 and 2 x 2.8).= ++9Ø 40 mm mushroom head Emergency stop pushbuttons (2)Trigger action (EN/ISO 13850)Type of pushPush-pull NO + NCUnmarked Products Complete For user assembly10References red NO + NC XB5AT845 ZB5AZ105 ZB5AT84Type of push Turn to release NO + NCReferences red NO + NC XB5AS8445 ZB5AZ105 ZB5AS844Type of push Key release NO + NCReferences red NO + NC XB5AS9445 ZB5AZ105 ZB5AS944(2) Emergency stop trigger action and mechanical latching pushbuttons conform to standards EN/IEC 60204-1 and EN/ISO 13850: to Machinery Directive 2006/42/EC and to standardEN/IEC 60947-5-5. Please consult your Regional Sales Office for a full explanation of these standards and directives.2/10Other versions: please consult our Customer Care Centre.


Contact functions= +1Selector switches and key switchesType of headCircular bezelDegree of protectionIP 66 / Nema 4X, 13 / Class IIMounting (mm) panel cut-out+ 0.4Ø 22.5 (22.4 0 recommended)mounting centres30 (horizontal) x 40 (vertical)Depth (mm) below head 43Connection (1)Screw clamp terminalsType of operatorHandleProducts Complete For user assembly Complete For user assembly23Number and type of positions 2 positions 2 positions 2 positions 2 positionsstay put stay put spring return to left spring return to leftReferences black NO XB5AD21 ZB5AZ101 ZB5AD2 XB5AD41 ZB5AZ101 ZB5AD4Number and type of positions 3 positions 3 positions 3 positions 3 positionsstay put stay put spring return to centre spring return to centreReferences black NO + NO XB5AD33 ZB5AZ103 ZB5AD3 XB5AD53 ZB5AZ103 ZB5AD5Type of operator Key, n° 455Number and type of positions (2) 2 positions 2 positions 2 positions 2 positionsstay put stay put stay put stay putReferences black NO XB5AG21 ZB5AZ101 ZB5AG2 XB5AG41 ZB5AZ101 ZB5AG4(2) The symbol indicates key withdrawal position.4567Biometric switchDegree of protectionIP65Dimension WxHxD (mm)69,3 x 54 x 78,5 (total depth : front + rear)Mounting (mm) Ø 22.5Depth (mm) 39,7Supply voltage24 VDCOutput PNP - monostable PNP - bistableConnection 2m cable M12 connector 2m cable M12 connectorReferences XB5S1B2L2 XB5S1B2M12 XB5S2B2L2 XB5S2B2M1289Body/fixing collar Fixing nut Bezel tool Platefor electrical block (contact or light) for head for tightening fixing nut ZB5AZ901 anti-rotationReferences ZB5AZ009 (10)* ZB5AZ901 (10)* ZB5AZ905 ZB5AZ902(1) Alternative connections: plug-in connector, Faston connectors (6.35 and 2 x 2.8), spring clamp terminal(2) Refer to page 9 for Electrical blocks and accessories used with Harmony XB5plastic range* sold in lots of10Other versions: please consult our Customer Care Centre.2/11


HarmonyXB5Pushbuttons, switches and pilot lights Ø 22with plastic bezelLight functions1= +Pilot lights23Type of headCircular bezelSmooth lens capDegree of protectionIP 66 / Nema 4X, 13 / Class IIMounting (mm) panel cut-out+ 0.4Ø 22.5 (22.4 0 recommended)mounting centres30 (horizontal) x 40 (vertical)Depth below head 43Connection (1)Screw clamp terminalsLight source Integral LED Direct supply for BA 9s bulb (not included)Products Complete Complete For user assembly456Supply voltage 24 V AC/DC 110…120 V AC 230…240 V AC 250 V max., 2.4 W max.References white XB5AVB1 XB5AVG1 XB5AVM1 XB5AV61 ZB5AV6 ZB5AV01green XB5AVB3 XB5AVG3 XB5AVM3 XB5AV63 ZB5AV6 ZB5AV03red XB5AVB4 XB5AVG4 XB5AVM4 XB5AV64 ZB5AV6 ZB5AV04orange XB5AVB5 XB5AVG5 XB5AVM5 XB5AV65 ZB5AV6 ZB5AV05blue XB5AVB6 XB5AVG6 XB5AVM6 – – –= +Illuminated pushbuttons and selector switchesTypeFlush push, spring return, illuminated pushbuttonsLight source Integral LED Direct supply for BA 9s bulb (not included)Products Complete Complete For user assembly78Supply voltage 24 V AC/DC 110…120 V AC 230…240 V AC 250 V max., 2.4 W max.References white NO + NC XB5AW31B5 XB5AW31G5 XB5AW31M5 XB5AW3165 ZB5AW065 ZB5AW31green NO + NC XB5AW33B5 XB5AW33G5 XB5AW33M5 XB5AW3365 ZB5AW065 ZB5AW33red NO + NC XB5AW34B5 XB5AW34G5 XB5AW34M5 XB5AW3465 ZB5AW065 ZB5AW34orange NO + NC XB5AW35B5 XB5AW35G5 XB5AW35M5 XB5AW3565 ZB5AW065 ZB5AW35blue NO + NC XB5AW36B5 XB5AW36G5 XB5AW36M5 – – –910Type Double-headed pushbuttons with LED pilot light Illuminated selector switches(1 flush green push, 1 projecting red push) (2 position stay put)Degree of protection IP 66 - IP 69K IP 66Light source Integral LED Integral LEDProducts Complete CompleteSupply voltage 24 V AC/DC 110…120 V AC 230…240 V AC 24 V AC/DC 110…120 V AC 230…240 V ACReferences green NO + NC – – – XB5AK123B5 XB5AK123G5 XB5AK123M5red NO + NC – – – XB5AK124B5 XB5AK124G5 XB5AK124M5orange NO + NC – – – XB5AK125B5 XB5AK125G5 XB5AK125M5white NO + NC XB5AW73731B5 XB5AW73731G5 XB5AW73731M5 – – –(1) Alternative connections: plug-in connector, Faston connectors (6.35 and 2 x 2.8), spring clamp terminal.Separate components and accessories: see previous page.2/12Other versions: please consult our Customer Care Centre.


HarmonyXALControl stationsFor XB5pushbuttons, switches and pilot lightsØ 22 with plastic bezel(1):Number of cut-outs Number (p)1 12 23 34 45 5Complete stations with 1 pushbutton, selector switch or key switch(light grey RAL 7035 base with dark grey RAL 7016 lid)Degree of protectionIP 65 / Nema 4X and 13 / Class IIDimensions (mm) W x H x D 68 x 68 x 113 max. (with key release Ø 40 mushroom head pushbutton)Fixing (mm)2 x Ø 4.3 on 54 mm centresFunction 1 Start or Stop function 1 Start-Stop functionMarking On spring return push On legend holder and legend below headNumber and type of pushbutton/selector switch/key switch 1 flush green p/b 1 flush red p/b 1 projecting red p/b 1 2 position stay put selector switch or key switchBlack handle Key n° 455 (key withdrawal LH pos.)References NO I XALD102 – – – –Start XALD103 – – – –O - I – – – XALD134 XALD144O – XALD112 XALD115 – –(1) Empty enclosures:Basic reference: XALK0p, replace the pby the number of cut-outs required (seecut-out table above)FunctionEmergency stop (2) (light grey RAL 7035 base with yellow RAL 1012 lid)Number and type of mushroom head pushbutton 1 red Ø 40 head, turn to release 1 red Ø 40 head, key releaseLatching mechanism Trigger action (EN/ISO 13850) Trigger action (EN/ISO 13850)References NC XALK178 XALK188NC + NC XALK178F XALK188FNO + NC XALK178E XALK188ENC + NC + NO XALK178G XALK188G(2) Emergency stop trigger action and mechanical latching pushbuttons conform to standards EN/IEC 60204-1 and EN/ISO 13850, to Machinery Directive 2006/42/EC and to standardEN/IEC 60947-5-5. Please consult your Regional Sales Office for a full explanation of these standards and directives.123456(1) Empty enclosures:Basic reference: XALD0p, replace the pby the number of cut-outs required (seecut-out table above)Complete stations with 2 and 3 pushbuttons or 2 pushbuttons + 1 pilot light(light grey RAL 7035 base with dark grey RAL 7016 lid)Dimensions (mm) W x H x D 2-way control stations: 68 x 106 x 62; 3-way control stations: 68 x 136 x 87Fixing (mm)2-way control stations: 2 x Ø 4.3 on 54 x 68 centres; 3-way control stations: 2 x Ø 4.3 on 54 x 98 centresFunction Start-Stop functions 2 functions 3 functionsMarkingOn spring return pushNumber and type of pushbutton/pilot light 1 flush green p/b 1 flush green pushbutton 1 flush white p/b 1 flush white p/b 1 flush white p/b1 flush red p/b 1 flush red pushbutton 1 flush black p/b 1 flush red p/b 1 Ø 30 red mush-1 red pilot light with integral LED 1 flush black p/b room head p/b1 flush black p/b24 V AC/DC 230 V ACReferences NO + NC I - O XALD213 XALD363B XALD363M – – –Start - Stop XALD215 – – – – –NO + NO – – – XALD222 – –NO + NC + NO – – – – XALD324 XALD328Accessories Standard contact blocks Light blocks with integral LED, colour redDescription NO contact NC contact 24 V AC/DC 230 V ACReferences ZENL1111 ZENL1121 ZALVB4 ZALVM478910Other versions: please consult our Customer Care Centre.2/13


HarmonyXB7Pushbuttons, switches and pilot lights Ø 22with plastic bezel - MonolithicContact functions1Available 3Q 2011Pushbuttons2345Type of headFlush or projecting pushcircularDegree of protectionIP 65, class IIMounting (mm) panel cut-out Ø 22.4 (0 +0.1)mounting centres30 (horizontal) x 40 (vertical)Dimensions (mm) Ø x Depth (below head) Ø 29 x 41.5 (Ø 40 x 41.5 for Emergency stop)Connection Screw clamp terminals, 1 x 0.34 mm 2 to 1 x 1.5 mm 2Type of push Flush, spring return Flush, push and latchingReferences (10)* white NO XB7NA11 –NO + NC XB7NA15 –black NO XB7NA21 XB7NH21NO + NC XB7NA25 XB7NH25green NO XB7NA31 XB7NH31NO + NC XB7NA35 XB7NH35red NC XB7NA42 –NO + NC XB7NA45 –yellow NO XB7NA81 –Type of push Flush, spring return Projecting, spring returnReferences green NO XB7NA3131 –red NC – XB7EL4232white NO XB7NA11341 –black NO XB7NA21341 –NO + NC XB7NA25341 –678Selector switches and key switchesType of operator Black handle Ronis key, n° 455Number and2 positions 3 positions 2 positions 3 positionstype of positionsstay put stay put stay put stay putReferences (10*) NO XB7ND21 – XB7NG21 –NO + NC XB7ND25 – – –2 NO – XB7ND33 – XB7NG339Ø 40 mushroom head pushbuttons (1)10Type of push Turn to release Key release, Ronis 455References (10)* red NC XB7ES542P XB7ES142Pred NO + NC XB7ES545P XB7ES145P(1) Mushroom head switching off mechanical latching pushbuttons conform to standard IEC 60364-5-53 and EN/IEC 60947-5-5. For mushroom trigger action and mechanicallatching head Emergency stop pushbuttons conforming to standard EN/IEC 60204-1 and EN/ISO 13850, to Machinery directive 2006/42/EC and standard EN/IEC 60947-5-5, usean Emergency stop type XB5Ap8ppp or XB5AS9ppp from the Harmony® range. See page 2/10.* sold in lots of 102/14Other versions: please consult our Customer Care Centre.


Contact functions and light functions(1):Supply voltage for integral LED light source only Letter (p)24 V AC/DC B120 V AC G230 V AC M1Illuminated pushbuttonsType of headProjecting pushcircularDegree of protectionIP 65, class IIMounting (mm) panel cut-out Ø 22.4 (0 +0.1)mounting centres30 (horizontal) x 40 (vertical)Dimensions (mm) Ø x Depth (below head) Ø 29 x 41.5, (Ø 40 x 41.5 for Emergency stop)Connection Screw clamp terminals, 1 x 0.34 mm 2 to 1 x 1.5 mm 2Light source Integral LED BA 9s base fitting Incandescent bulbdirect supply (bulb not included)Type of pushSpring returnReferences (10)* green NO XB7NW33p1 (1) XB7NW3361red NO XB7NW34p1 (1) XB7NW3461NC XB7NW34p2 (1) –orange NO XB7NW35p1 (1) –blue NO XB7NW36p1 (1) –clear NO XB7NW37p1 (1) –yellow NO XB7NW38p1 (1) XB7NW3561Type of pushPush and latchingReferences (10)* green NO XB7NH03p1 (1) XB7NH0361red NO XB7NH04p1 (1) XB7NH0461NC XB7NH04p2 (1) –yellow NO XB7NH08p1 (1) XB7NH086123456Pilot lights (2)7Light source Integral LED Ba 9s base fitting incandescent bulb Incandescent bulbdirect supplydirect through resistor(bulb not included)(bulb included)Supply voltage 24VAC/DC or 120VAC or 230…240VAC 6 or 24 V DC, or 130 V AC 230 V ACReferences (10)* clear XB7EV07p (1) XB7EV67 XB7EV77green XB7EV03p (1) XB7EV63 XB7EV73red XB7EV04p (1) XB7EV64 XB7EV74yellow XB7EV05p (1) XB7EV65 XB7EV75blue XB7EV06p (1) XB7EV66 XB7EV76orange XB7EV08p (1) XB7EV68 XB7EV7889Incandescent bulbs, long lifeBA 9s base fitting, Ø 11 mm max., length 28 mm max.6 V (1.2 W) 24 V (2 W) 130 V (2.4 W)References DL1CB006 DL1CE024 DL1CE130(1) Basic reference, to be completed by the letter B, G or M indicating the required voltage. See voltage table above.(2) Alternative connection: 1 x 6.35 and 2 x 2.8 mm Faston connectors.* sold in lots of 1010Other versions: please consult our Customer Care Centre.2/15


Harmony9001K/SKPushbuttons, switches and pilot lights Ø 30with metal bezelContact functions1Pushbuttons, spring return23Type of push Flush Projecting Projecting (high guard)Colour of pushMulti-colour (set of 7 clip-in coloured caps)Degree of protectionIP 66 / Nema 1, 2, 3, 3R, 4, 6, 12 and 13 / Class IIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp), 57.2 x 50.8 (with legend 9001KN3pp)Depth below head (mm) 42ConnectionScrew clamp terminalsReferences CO 9001KR1UH13 9001KR3UH13 9001KR2UH13NO 9001KR1UH5 9001KR3UH5 9001KR2UH54Mushroom head pushbuttons, latching (1) Emergency switching off Emergency stop567Type of push Push-pull Turn-to-Release, trigger actionØ 41 mushroom head Ø 35 mushroom head Ø 40 red mushroom headDegree of protection IP 66 / Nema 1, 2, 3, 3R, 4, 6, 12 and 13 / Class II IP 66 / Nema 1, 2, 3, 3R, 4, 6, 12 and 13 / Class IIIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp),57.2 x 50.8 (with legend 9001KN3pp)57,2 x 44,5 (without legend plate),100 x 100 ((with legend plate 9001KN8330) (2)Depth below head (mm) 42 60ConnectionScrew clamp terminalsReferences – – – 9001KR16CO 9001KR9R94H13 9001KR9R20H13 –NC 9001KR9RH6 9001KR9R20H6 –2NO + 2NC – – 9001KR16H2NO – – 9001KR16H13(1) Mushroom head switching off mechanical latching pushbuttons conform to standard IEC 60364-5-53 and EN/IEC 60947-5-5. Mushroom trigger action and mechanicallatching head Emergency stop pushbuttons conforming to standard EN/IEC 60204-1 and EN/ISO 13850, to Machinery directive 2006/42/EC and standard EN/IEC 60947-5-5.(2) For yellow circular Emergency Stop legend plates: see page 2/198Selector switches and key switches910Type of operator Long black handle Key, n° 455positions (2) 3 - spring return 2 - stay put 2 - spring return 3 - stay put 2 - stay putNumber and typeof positionsDegree of protectionIP 66 / Nema 1, 2, 3, 3R, 4, 6, 12 and 13 / Class IIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp), 57.2 x 50.8 (with legend 9001KN3pp)Depth below head (mm) 42ConnectionScrew clamp terminalsReferences NO – 9001KS11FBH5 9001KS34FBH5 – –CO 9001KS53FBH1 – – 9001KS43FBH1 9001KS11K1RH1(2) The symbol indicates key withdrawal position.2/16Other versions: please consult our Customer Care Centre.


Light functions1Pilot lightsType of headSmooth lens capDegree of protectionIP 66 / Nema 1, 2, 3, 3R, 4, 6, 12 and 13 / Class IIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp), 57.2 x 50.8 (with legend 9001KN3pp)Depth below head (mm) 42ConnectionScrew clamp terminalsType of light block With high luminosity LED (included) Incandescent BA 9s bulb(included)24 V AC/DC 48 V AC/DC 120 V AC/DC 230 V ACReferences green 9001KP35LGG9 9001KP36LGG9 9001KP38LGG9 9001KP7G9red 9001KP35LRR9 9001KP36LRR9 9001KP38LRR9 9001KP7R9yellow 9001KP35LYA9 9001KP36LYA9 9001KP38LYA9 9001KP7A9234Illuminated pushbuttons, spring returnType of headSpring return flush pushDegree of protectionIP 66 / Nema 1, 2, 3, 3R, 4, 6, 12 and 13 / Class IIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp), 57.2 x 50.8 (with legend 9001KN3pp)Depth below head (mm) 42ConnectionScrew clamp terminalsType of light block With high luminosity LED (included) Incandescent BA 9s bulb(included)24 V AC/DC 48 V AC/DC 120 V AC/DC 230 V ACReferences green CO 9001K3L35LGGH13 9001K3L36LGGH13 9001K3L38LGGH13 9001K2L7RH13red CO 9001K3L35LRRH13 9001K3L36LRRH13 9001K3L38LRRH13 9001K2L7GH13yellow CO 9001K3L35LYAH13 9001K3L36LYAH13 9001K3L38LYAH13 9001K2L7AH13567Illuminated Ø 41 mushroom head pushbuttons, latching, high luminosity LEDDegree of protectionIP 66 / Nema 1, 2, 3, 3R, 4, 6, 12 and 13 / Class IIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp), 57.2 x 50.8 (with legend 9001KN3pp)Depth below head (mm) 42ConnectionScrew clamp terminalsType of light block With high luminosity LED (included) Incandescent BA 9s bulb(included)24 V AC/DC 48 V AC/DC 120 V AC/DC 230 V AC/DCType of head2 position, push-pullReferences red CO 9001KR9P35RH13 9001KR9P36RH13 9001KR9P38RH13 9001KR9P7RH13Type of head3 position, push-pull (pull: spring return, centre: stay put, push: spring return)References red NC + NC 9001KR8P35RH25 9001KR8P36RH25 9001KR8P38RH25 9001KR8P7RH25late break8910Other versions: please consult our Customer Care Centre.2/17


Harmony9001K/SKPushbuttons, switches and pilot lights Ø 30with plastic bezelContact functions and light functions1Pushbuttons, spring return23Type of push Flush Projecting Projecting (high guard)Colour of pushMulti-colour (set of 7 clip-in coloured caps)Degree of protectionIP 66 / Nema 1, 2, 3, 3R, 4, 4X, 12 and 13 / Class IIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp), 57.2 x 50.8 (with legend 9001KN3pp)Depth below head (mm) 42ConnectionScrew clamp terminalsReferences CO 9001SKR1UH13 9001SKR3UH13 9001SKR2UH13NO 9001SKR1UH5 9001SKR3UH5 9001SKR2UH54567Type Selector switches Mushroom head pushbuttons (1)Emergency stopType of operator Long black handle Turn-to-Release, trigger actionpositions 2 - stay put 2 - spring return 3 - stay put Ø 40 red mushroom headNumber and typeof positionsDegree of protection IP 66 / Nema 1, 2, 3, 3R, 4, 4X, 12 and 13 / Class II IP 66 / Nema 1, 2, 3, 3R, 4, 4X, 6, 12 and 13 / Class IIIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp),57.2 x 50.8 (with legend 9001KN3pp)57,2 x 44,5 (without legend plate),100 x 100 ((with legend plate 9001KN8330) (2)Depth below head (mm) 42 60ConnectionScrew clamp terminalsReferences – – – – 9001SKR16NO 9001SKS11FBH5 9001SKS34FBH5 – 9001SKR16H13CO – – 9001SKS43FBH1 –2NO + 2NC – – – 9001SKR16H2(1) Mushroom trigger action and mechanical latching head Emergency stop pushbuttons conforming to standard EN/IEC 60204-1 and EN/ISO 13850, to Machinery directive2006/42/EC and standard EN/IEC 60947-5-5.(2) For yellow circular Emergency Stop legend plates: see page 2/198Pilot lights910Type of headSmooth lens capDegree of protectionIP 66 / Nema 1, 2, 3, 3R, 4, 4X, 12 and 13 / Class IIMounting (mm) panel cut-out Ø 31mounting centres57.2 x 44.5 (with legend 9001KN2pp), 57.2 x 50.8 (with legend 9001KN3pp)Depth below head (mm) 42ConnectionScrew clamp terminalsType of light block With high luminosity LED (included) Incandescent BA 9s bulb(included)24 V AC/DC 48 V AC/DC 120 V AC/DC 230 V ACReferences green 9001SKP35LGG9 9001SKP36LGG9 9001SKP38LGG9 9001SKP7G9red 9001SKP35LRR9 9001SKP36LRR9 9001SKP38LRR9 9001SKP7R9yellow 9001SKP35LYA9 9001SKP36LYA9 9001SKP38LYA9 9001SKP7A92/18Other versions: please consult our Customer Care Centre.


Accessories1Contact blocks with protected terminalsType of contactSingle contact blocksConnectionScrew clamp terminalsReferences CO 9001KA1NO9001KA2NC9001KA3CO, late break9001KA4NC, late break9001KA5NO, early make9001KA6234EnclosuresType Number of Ø 30 mm cut-outs NEMA ratings ReferenceAluminium 1 1, 3, 4, 6, 12, 13 9001KY12 1, 3, 4, 6, 12, 13 9001KY23 1, 3, 4, 6, 12, 13 9001KY34 1, 3, 4, 6, 12, 13 9001KY4Stainless steel 1 1, 3, 4, 4X, 13 9001KYSS12 1, 3, 4, 4X, 13 9001KYSS23 1, 3, 4, 4X, 13 9001KYSS3567Legends44 x 43 mm 57 x 57 mm Ø 60 Ø 90Type Aluminium Plastic PlasticColour of legend black background white background Yellow backgroundMarking Blank 9001KN200 9001KN100WP 9001KN9100 9001KN8100START 9001KN201 9001KN101WP – –STOP (red background) 9001KN202 9001KN102RP – –FORWARD 9001KN206 9001KN106WP – –REVERSE 9001KN207 9001KN107WP – –RESET 9001KN223 9001KN123WP –PULL TO START/ 9001KN379 9001KN179WP – –PUSH TO STOPEMERGENCY STOP – – 9001KN9330 9001KN8330ARRET D’URGENCE – – 9001KN9330F 9001KN8330FPARADA DE EMERGENCIA – – 9001KN9330S 9001KN8330S8910Other versions: please consult our Customer Care Centre.2/19


HarmonyK seriesCam switches12 and 20 A ratingspositions (°)11-pole2-pole04512342-pole09012342-pole04590135 180 22512345678Cam switches, K1 / K2 series23Function Switches ON-OFF switches Stepping switches45° switching angle 90° switching angle with “0” positionDegree of protection front face IP 65 (1) IP 65 (1) IP 65 (1)Conventional thermal current (Ith) 12 A 20 A 12 A 20 A 12 A 20 ARated insulation voltage (Ui) conforming to IEC60947-1 690 V 690 V 690 VNumber of positions 2 2 2 + “0” positionNumber of poles 2 2 2Dimensions of front plate (mm) 45 x 45 45 x 45 45 x 45Front mounting method Multifixing plate, 45 x 45 mm K1B002ALH K2B 002ALH K1B1002HLH K2B 1002HLH K1D012QLH K2D012QLHPlastic mounting plate for Ø 22 mm hole K1B002ACH K2B 002ACH K1B1002HCH K2B 1002HCH K1D012QCH K2D012QCH45positions (°)0 90180270225270 31501 234315045812 1-pole125637482-pole5691071145 901351 234Cam switches, K1 / K2 seriesFunction Changeover switches Ammeter switches Voltmeter switches5678910111267Degree of protection front face IP 65 (1) IP 65 (1) IP 65 (1)Conventional thermal current (Ith) 12 A 20 A 12 A 20 A 12 A 20 ARated insulation voltage (Ui) conforming to IEC60947-1 690 V 690 V 690 VNumber of positions 2 + “0” position 3 + “0” position 6 + “0” position (measurements(3 circuits + “0” position) between 3 phases & N + “0” pos.)Number of poles 2 4 7Dimensions of front plate (mm) 45 x 45 45 x 45 45 x 45Front mounting method Multifixing plate, 45 x 45 mm K1D002ULH K2D002ULH K1F003MLH to be compiled * K1F027MLH to be compiled *Plastic mounting plate for Ø 22 mm hole K1D002UCH K2D002UCH K1F003MCH to be compiled * K1F027MCH to be compiled *(1) With seal KZ73 for switch with Multifixing plate, with seal KZ65 for Ø 22 mm hole mounting switches. Seal to be ordered separately.(*) Please consult your Schneider Electric agency.8910positions (°)060 1201 234567891011120 60120 1801234563000 60789101112131412345678Cam switches with key operated lock, K1 seriesFunction Stepping switches Run switches Changeover switches + “0” pos.Degree of protection front face IP 65 IP 65 IP 65Conventional thermal current (Ith) 12 A 12 A 12 ARated insulation voltage (Ui) conforming to IEC60947-1 690 V 690 V 690 VNumber of positions 2 + “0” position 3 + “0” position 2 + “0” positionNumber of poles 3 2 2Dimensions of front plate (mm) 55 x 100 55 x 100 55 x 100Colour of handle red black red black red blackFront mounting method Ø 22 mm hole + Ø 43.5 mm hole K1F022QZ2 K1F022QZ4 K1G043RZ2 K1G043RZ4 K1D002UZ2 K1D002UZ42/20Other versions: please consult our Customer Care Centre.


10 to 150 A ratingspositions (°)1-pole2-pole3-pole0601234561-pole2-pole3-pole3000601234567891011120 90180270123456789101112270 3003300 30 60 901 234567891011121Cam switches, K10seriesFunction Switches Changeover switches Ammeter Voltmeter60° switching angle with “0” position switches switchesDegree of protection front face IP 65 IP 65 IP 65 IP 65Conventional thermal current (Ith) 10 A 10 A 10 A 10 ARated insulation voltage (Ui) conforming to IEC60947-1 440 V 440 V 440 V 440 VNumber of positions 2 2 + “0” position 3 + “0” pos. (1) 6 + “0” pos. (2)Number of poles 1 2 3 2 3 3 3Dimensions of front plate (mm) 30 x 30 30 x 30 30 x 30 30 x 30Front mounting method By Ø 16 mm or 22 mm hole K10A001ACH K10B002ACH K10C003ACH K10D002UCH K10F003UCH K10F003MCH K10F027MCH(1) (3 circuits + “0” position).(2) (Measurements between 3 phases and N + “0” position).positions (°)01-pole2-pole3-pole0601 234561-pole2-poleCam switches, K30seriesFunction Switches Switches Changeover Starting Starting ReversingON-OFF with “0” position star-delta 2-speedDegree of protection front face IP 40 IP 40 IP 40 IP 40 IP 40 IP 40Conventional thermal current (Ith) 32 A 32 A 32 A 32 A 32 A 32 ARated insulation voltage (Ui) conforming to IEC60947-1 690 V 690 V 690 V 690 V 690 V 690 VNumber of positions 2 2 3 3 3 3Number of poles 3 3 4 4 3 3 3Dimensions of front plate (mm) 64 x 64 64 x 64 64 x 64 64 x 64 64 x 64 64 x 64Front mounting method Multifixing K30C003AP (3) K30C003HP (3) K30D004HP (3) K30H004UP (3) K30H001YP (3) K30H004PP (3) K30E003WP(3)(3) To order switches with other thermal current ratings (50, 63, 115, 150 A): replace the number 30 in the reference by 50, 63, 115 or 150 respectively.Example: a switch with a 32 A current rating, for example K30C003AP, becomes K50 C003AP for a current rating of 50 A.90123456781-pole2-pole3-pole4-pole300060123456789101112131415163000601234567891011121314151630006012343000605162738495106117128139141015111612234567Accessories for cam switches K1/K28Rubber sealsfor IP 65 degree of protectionFor use with heads with 45 x 45 mm front plate with 60 x 60 mm front plate with 45 x 45 mm front plateØ 22 mm hole or 4 hole front mtg. Ø 22 mm hole or 4 hole front mtg. multifixingReferences (5)* KZ65 KZ66 KZ73* sold in lots of910Other versions: please consult our Customer Care Centre.2/21


HarmonyXVCMonolithic tower lightsØ 40, Ø 60, Ø 100 mm, complete, pre-wiredtower lights1Ø 40 mm / Up to IP54234Complete, pre-wired tower lights Steady light Steady / Flashing light (1)Light source (included) LEDs LEDsBase mount Base mounting Support tube mounting, 17 mm Support tube mounting, 17 mmBuzzer Without buzzer With buzzer + flashing lightDegree of protection up to IP54 up to IP54Voltage 24V AC/DC 24V AC/DC 100-240V AC 24V AC/DC 100 - 240V ACReferences (2) Red XVC4B1K XVC4B1 XVC4M1 XVC4B15S XVC4M15SRed / orange XVC4B2K XVC4B2 XVC4M2 XVC4B25S XVC4M25SRed / Orange / green XVC4B3K XVC4B3 XVC4M3 XVC4B35S XVC4M35Sred / orange / green / blue XVC4B4K XVC4B4 XVC4M4 XVC4B45S XVC4M45Sred / orange / green / blue / Clear XVC4B5K XVC4B5 XVC4M5 XVC4B55S XVC4M55S5Ø 60 mm / Up to IP54Complete, pre-wired tower lights Steady light Steady / Flashing light (1)67Light source (included) LEDs LEDsBase mount Base mounting Support tube mounting, 22 mm Support tube mounting, 22 mm Base mountingBuzzer Without buzzer With buzzer + flashing lightDegree of protection up to IP54 up to IP54Voltage 24V AC/DC 24V AC/DC 100-240V AC 24V AC/DC 100 - 240V ACReferences (2) Red XVC6B1K XVC6B1 XVC6M1 (3) XVC6B15S (3) XVC6M15S XVC6M15SKRed / orange XVC6B2K XVC6B2 XVC6M2 (3) XVC6B25S (3) XVC6M25S XVC6M25SKRed / Orange / green XVC6B3K XVC6B3 XVC6M3 (3) XVC6B35S (3) XVC6M35S XVC6M35SKred / orange / green / blue XVC6B4K XVC6B4 XVC6M4 (3) XVC6B45S (3) XVC6M45S XVC6M45SKred / orange / green / blue / Clear XVC6B5K XVC6B5 XVC6M5 (3) XVC6B55S (3) XVC6M55S XVC6M55SK(3) To order products for base mounting, add the letter K to the end of the reference (ex. XVC6M1K)8Ø 100 mm / Up to IP54Complete, pre-wired tower lights Steady / Flashing light (1)910Light source (included)LEDsBase mountBase mountingBuzzer Without buzzer With buzzer + flashing lightDegree of protection up to IP54 up to IP54Voltage 24V DC 100-240V AC 24V DC 100-240V AC 24V DC 100 - 240V ACReferences (2) Red XVC1B1K XVC1M1K XVC1B1SK XVC1M1SK XVC1B1HK XVC1M1HKRed / orange XVC1B2K XVC1M2K XVC1B2SK XVC1M2SK XVC1B2HK XVC1M2HKRed / Orange / green XVC1B3K XVC1M3K XVC1B3SK XVC1M3SK XVC1B3HK XVC1M3HKred / orange / green / blue XVC1B4K XVC1M4K XVC1B4SK XVC1M4SK - -red / orange / green / blue / Clear XVC1B5K XVC1M5K XVC1B5SK XVC1M5SK - -(1) Flashing function can be simply selected/programmed by wiring(2) The colours are listed in the same order as the mounting order of the illuminated units (from top to bottom)2/22Other versions: please consult our Customer Care Centre.


HarmonyXVDLS / XVCMonolithic tower lights and accessoriesØ 45 mm, complete illuminated beacons1Ø 45 mm / IP40Illuminated beacons XVDLS Steady light Flashing lightLight source Incandescent BA 15d bulb, 5 W max. (not included) “Flash” discharge tube, 0.5 JDegree of protection IP 40References (1) 24…230 V AC/DC XVDLS3p –24 V AC/DC – XVDLS6Bp120 V AC – XVDLS6Gp230 V AC – XVDLS6Mp(1) To obtain the complete reference, replace the p by the number designating the colour as follow: 3 = green , 4 = red , 5 = orange, 6 = blue, 7 = clear, 8 = yellow.23AccessoriesXVDLSIncandescent bulbs, with BA 15d baseBeacons XVDLSDescription 24 V, 4 W 120 V, 5 W 230 V, 5 WReferences DL1BEBS DL1BEGS DL1BEMSXVC4 / XVC6Mounting accessories Tower lights Ø 40 mm, XVC4 Tower lights Ø 60 mm, XVC6Description Support tube mounting Support tubemountingBase mounting Support tubemountingDiameter (mm) Ø 90 Ø 84 – Ø 100 Ø 84 –For use with – – – XVC6ppandXVC6pp5SXVC6ppK andXVC6pp5SKXVC6BpandXVC6Bpp5S,XVC6MpandXVC6Mp5SHeight to be added (mm) 32 24,5 82 30 21,6 82References Metal fixing plate XVCZ11 – – XVCZ02 XVCZ12 –Plastic fixing plate – XVCZ01 – – – –Wall mounting bracket – – XVCZ31 – – XVCZ3245678XVC1Mounting accessoriesTower lights Ø 100 mm, XVC19DescriptionVertical supportDiameter (mm) Ø 140 Ø 140 – –For use withXVC1ppK XVC1ppHK (with siren) XVC1ppK and XVC1ppSK XVC1ppHKand(with siren)XVC1ppSKHeight to be added (mm) 300 306 – –References Metal fixing plate (2) XVCZ13 XVCZ14 – –Metal fixing bracket – – XVCZ23 XVCZ24(2) Chromium plated-steel extension tubeOther versions: please consult our Customer Care Centre.2/2310


HarmonyXVBModular tower lightsØ 70 mm, for customer assembly1Ø 70 mm / Up to IP6623Illuminated beacons XVBL Steady light Flashing lightLight source Incandescent BA 15d bulb, Protected BA 15d LED Protected BA 15d LED “Flash” discharge tube10 W max. (not included) (included) (included) 5 J (2)Degree of protection IP 66References (1) 12…250 V AC/DC XVBL3p – – –24 V AC/DC – XVBL0Bp XVBL1Bp XVBL6Bp120 V AC – XVBL0Gp XVBL1Gp XVBL6Gp230 V AC – XVBL0Mp XVBL1Mp XVBL6Mp4Ø 70 mm / Up to IP665678Tower lights XVBCcomprising 2 to 5 signalling units (3)Base units Steady light Flashinglight“Flash”lightAudibleunits (90 dbat 1 m)Light source – Incandescent Integral Integral “Flash” –BA 15d bulb, 10 W protected LED protected LED discharge tubemax. (not included) 5 J (2)Degree of protection IP 66Base unit references with cover XVBC21 (4) – – – – –without cover XVBC07 (5) – – – – –References (2) 12… 230 V AC/DC – XVBC3p – – – –24 V AC/DC – – XVBC2Bp XVBC5Bp XVBC6Bp –120 V AC – – XVBC2Gp XVBC5Gp XVBC6Gp –230 V AC – – XVBC2Mp XVBC5Mp XVBC6Mp –Audible unit references 12…48 V AC/DC – – – – – XVBC9Bunidirectional 120…230 V AC – – – – – XVBC9M(1) To obtain the complete reference, replace thep by the number designating the colour as follow: 3 = green , 4 = red , 5 = orange, 6 = blue, 7 = clear, 8 = yellow.(2) To order a lens unit with a 10 J discharge tube, replace the number 6 by 8 in the reference (example: XVBL6Bp becomes XVBL8Bp).(3) A tower light comprises: 1 base unit + 1 to 5 signalling units maximum.(4) For connection on AS-Interface, order base unit XVBC21A (side cable entry) or XVBC21B (bottom cable entry with M12 connector on flying lead).(5) For indicator banks with “flash” discharge tube unit.9102/24Other versions: please consult our Customer Care Centre.


HarmonyXVEModular tower lightsØ 70 mm, for customer assembly1Ø 70 mm / Up to IP54Illuminated beacons XVEL Steady light Flashing lightLight source Incandescent Integral “Flash” discharge tube, 1 JBA 15d bulb, 5 W max.LED(not included)Degree of protectionIP 42/IP 54 (with sealing kit)References (1) 24… 240 V AC/DC XVEL3p –24 V AC/DC – XVEL2Bp XVEL6Bp120 V AC – XVEL2Gp XVEL6Gp230 V AC – XVEL2Mp XVEL6Mp234Ø 70 mm / Up to IP54Indicator banks XVECcomprising 2 to 5 signalling units (2)Base units Steady light Flashinglight“Flash”lightAudibleunits (85 dbat 1 m)Light source – Incandescent Integral Integral “Flash” –BA 15d bulb, 5 W LED LED discharge tubemax. (not included)1 JDegree of protectionIP 42/IP 54 (with sealing kit)Base unit references IP 42 XVEC21 – – – – –IP 54 XVEC21P – – – – –Lens unit references (1) 24…230 V AC/DC – XVEC3p –24 V AC/DC – – XVEC2Bp XVEC5Bp XVEC6Bp XVEC9B120 V AC – – XVEC2Gp XVEC5Gp XVEC6Gp XVEC9G230 V AC – – XVEC2Mp XVEC5Mp XVEC6Mp XVEC9M(1) To obtain the complete reference, replace thep by the number designating the colour as follow: 3 = green , 4 = red , 5 = orange, 6 = blue, 7 = clear, 8 = yellow.(2) A tower light comprises: 1 base unit + 1 to 5 signalling units maximum.5678910Other versions: please consult our Customer Care Centre.2/25


HarmonyXVM / XVPModular tower lightsØ 45, Ø 50 mm, complete orfor customer assembly1234Ø 45 mm / IP42Complete, pre-wired tower light XVM (1) 2 sig. units + integral buzzer (2) 3 signalling units + integral buzzer (2)Steady lightSteady light Steady light + “flash” (3)Light source (included) Incandescent BA 15d Incandescent BA 15d Incandescent BA 15dBA 15d bulb, 5 W “Super bright” BA 15d bulb, 5 W “Super bright” BA 15d bulb, 5 W “Super bright”max. LEDmax. LEDmax.LEDDegree of protection IP 54Signalling colours Red - Green Red - Orange - GreenReferences 24 V AC/DC XVMB1RGS XVMB2RGSSB XVMB1RAGS XVMB2RAGSSB XVMB1R6AGS XVMB2R6AGSSB120 V AC/DC (bulb) - 120 V AC (LED) XVMG1RGS XVMG2RGSSB XVMG1RAGS XVMG2RAGSSB XVMG1R6AGS XVMG2R6AGSSB230 V AC/DC (bulb) - 230 V AC (LED) XVMM1RGS XVMM2RGSSB XVMM1RAGS XVMM2RAGSSB XVMM1RA6GS XVMM2R6AGSSB(1) Tower lights XVM are also available as separate components for customised assembly by the user: please refer to www.schneider-electric.com.(2) To order products without an integral buzzer, delete the letter S at the end of the reference (example: XVMB2RGS becomes XVMB2RG).(3) Flash signalling colour: red - 0.8 J.5678Ø 50 mm / IP65Tower lights XVPcomprising 2 to 5 signalling units (4),black clamping ring (5)Base unitSteady orflashing lightsignalling“Flash” light signallingLight source – Incandescent “Flash” “Flash” –BA 15d bulb, 7 W discharge tube discharge tubemax. (not included) 0.3 J0.6 JDegree of protection IP 65Base unit with cover XVPC21 – – – –References (6) 250 V max. – XVPC3p – – –Audible units(55…85 dBat 1 m)24 V AC/DC (flash) - 24 V DC (buzzer) – – XVPC6Bp – XVPC09B120 V AC – – – XVPC6Gp XVPC09G230 V AC – – – XVPC6Mp XVPC09M(4) A tower light comprises: 1 base unit + 1 to 5 signalling units maximum.(5) To order products with a cream clamping ring, add the letter W to the end of the reference (example: base unit + green lens unit: XVPC21W + XVPC33W etc.).(6) To obtain the complete reference, replace thep by the number designating the colour as follow: 3 = green , 4 = red , 5 = orange, 6 = blue, 7 = clear, 8 = yellow.9102/26Other versions: please consult our Customer Care Centre.


HarmonyXVModular tower lights accessoriesFor XVB, XVP, XVE, XVM1BulbsBeacons and tower lightsXVB / XVP (1)Type of light source Incandescent Incandescent LED (2) FlashingBA 15d base BA 15d base BA 15d base LED (2)7 W 10 W (not XVP) BA 15d baseReferences 12 V DL1BEJ DL1BLJ – –24 V DL1BEB DL1BLB DL1BDBp DL1BKBp48 V DL1BEE DL1BLE – –120 V DL1BEG DL1BLG DL1BDGp DL1BKGp230 V DL1BEM DL1BLM DL1BDMp DL1BKMp(1) Tower lights XVP can be fitted with 5 W incandescent bulbs: see beacons XVDLS / XVE.(2) To obtain the complete reference, replace the p by the number designating the colour as follow: 1 = white, 3 = green , 4 = red , 5 = orange, 6 = blue, 8 = yellow.234BulbsTower lightsXVM / XVEType of light source Incandescent LED (3) Flashing “Flash” dischargeBA 15d base BA 15d base LED (3) tube, 0.8 Joule5 W BA 15d base BA 15d baseReferences 24 V DL1EDBS DL2EDBp DL1EKBp DL6BB120 V DL1EDGS DL2EDGp DL1EKGp DL6BG230 V DL1EDMS DL2EDMp DL1EKMp DL6BM(3) To obtain the complete reference, replace the p by the number designating the colour as follows: 1 = white, 3 = green , 4 = red , 6 = blue, 8 = orange.567Mounting accessoriesBeacons andTower lightsTower lightstower lightsXVB / XVEXVPXVMDescription Aluminium tube Plastic tube Aluminium tube Aluminium tube Aluminium tube Aluminium tubewith integral black with integral black with integral black with steel fixing with integral cream with steel fixingplastic fixing base plastic fixing base plastic fixing base bracket plastic fixing base bracketDiameter (mm) Ø 25 Ø 25 Ø 20 Ø 20 Ø 20 Ø 20Support tubes 60 mm XVEZ13 – – – – –100 mm – – – XVPC02T XVMZ02 XVMZ02T112 mm – – XVPC02 (4) – – –120 mm XVBZ02 – – – – –140 mm – XVDC02 – – – –250 mm – – – XVPC03T XVMZ03 XVMZ03T260 mm – – XVPC03 (4) – – –400 mm – – – XVPC04T XVMZ04 XVMZ04T410 mm – – XVPC04 (4) – – –420 mm XVBZ03 – – – – –820 mm XVBZ04 – – – – –Fixing plates, for vertical support XVBC12 XVPC12 (4) –for horizontal support XVBZ01 – XVMZ06(4) To order an aluminium support tube with integral cream fixing base, add the letter W to the end of the reference (example: XVPC02W).Other versions: please consult our Customer Care Centre.2/278910


HarmonyXVRRotating mirror beaconsØ 84, 106, 120, 130 mm rotating mirror beacons1Ø 84 / 106 mmComplete, pre-wired rotating mirror beacons Ø 84 mm Ø 106 mm23Light source (included)“ Super bright “ LEDsBase mount 3 x Ø 05BuzzerWithout buzzerDegree of protection IP23 (IP 65 with accessories) IP23 (IP 65 with accessories)Voltage 12V AC/DC 12V AC/DC 12V AC/DC 12V AC/DCReferences Red XVR08J04 XVR08B04 XVR10J04 XVR10B04Orange XVR08J05 XVR08B05 XVR10J05 XVR10B05Green XVR08J03 XVR08B03 XVR10J03 XVR10B03Blue XVR08J06 XVR08B06 XVR10J06 XVR10B06456Ø 120 mmComplete, pre-wired rotating mirror beaconsØ 120 mmLight source (included)“ Super bright “ LEDsBase mount3 x M5Buzzer Without buzzer With buzzerDegree of protectionIP23Voltage 12V AC/DC 24V AC/DC 12V AC/DC 24V AC/DCReferences Red XVR12J04 XVR12B04 XVR12J04S XVR12B04SOrange XVR12J05 XVR12B05 XVR12J05S XVR12B05SGreen XVR12J03 XVR12B03 XVR12J03S XVR12B03SBlue XVR12J06 XVR12B06 XVR12J06S XVR12B06S78Ø 130 mmComplete, pre-wired rotating mirror beaconsØ 130 mm9Light source (included)“ Super bright “ LEDsBase mount 3 x Ø 09BuzzerWithout buzzerDegree of protection IP66 - Resistant to vibration IP66 and IP67Voltage 12V DC 24V DC 24V AC/DC 120V AC 230V ACReferences Red XVR13J04 XVR13B04 XVR13B04L XVR13G04L XVR13M04LOrange XVR13J05 XVR13B05 XVR13B05L XVR13G05L XVR13M05L102/28Other versions: please consult our Customer Care Centre.


HarmonyXVR / XVSRotating mirror beacons accessoriesand sound solutionsAccessories for rotating mirror beacons1Accesories for rotating mirrors Reflecting prism Rubber base Metal angle Metal fixing platebracketTo be used for/with – Increasing the IP degree Horizontal support Horizontal supportHeight (mm) – – – 300References Ø 84 mm XVRZR1 XVRZ081 XVCZ23 –Ø 106 mm XVRZR2 XVRZ082 XVCZ23 XVCZ13Ø 120 mm XVRZR3 – XVCZ23 XVCZ13Ø 130 mm XVRZR3 – XVR012L –23Electronic alarms and multisound sirens45Sirens and electronic alarms Sirens Multisoundsirenspre-wiredElectronic alarmsPanel Mount DIN72Electronic alarmsPanel Mount DIN96Sound level 106 dB 105 dB 90 dB 96 dBTones 2 43 16 16Channels – 8 4 4Degree of protection IP 65 IP53 IP 54 IP 54Colors White White Black White Black WhiteReferences 12/24V AC/DC XVS10BMW – XVS72BMBp (1) XVS72BMWp (1) XVS96BMBp (1) XVS96BMWp (1)12/24V DC – XVS14BMW – – – –120V AC XVS10GMW XVS14GMW – – – –230V AC XVS10MMW XVS14MMW – – – –(1) To obtain a complete reference, replace the p by the letter as follow: P = PNP, N = NPN (ex. XVS72BMBP)678910Other versions: please consult our Customer Care Centre.2/29


HarmonyXACPendant control stationsfor control circuitsReady to use1Type XACA “Pistol grip”23Degree of protectionIP 65 / Nema 4, 4X / Class IIRated operational characteristics AC 15 (240 V 3 A), DC 13Conventional thermal current Ithe 10 AConnection Screw clamp terminals, 1 x 2.5 mm 2 or 2 x 1.5 mm 2For control of single-speed motors 2-speed motorsDimensions (mm) W x H x D 52 x 295 x 71 (x 85 with ZA2BS834) 52 x 295 x 71 (x 85 with ZA2BS834)Number of operators mechanically interlocked 2 2Emergency stop without ZA2BS834 without ZA2BS834References XACA201 XACA2014 XACA207 XACA207445Type XACA67For control of single-speed motorsDimensions (mm) W x H x D 80 x 314 x 70 (x 90 with ZA2BS834) 80 x 440 x 70 (x 90 with ZA2BS844)Number of operators mechanically interlocked between pairs 2 4Emergency stop without ZA2BS834 without ZA2BS844References XACA271 XACA2714 XACA471 XACA471489For control of single-speed motors+ I / O10Dimensions (mm) W x H x D 80 x 500 x 70 (x 90 with ZA2BS844) 80 x 560 x 70Number of operators mechanically interlocked between pairs 6 8Emergency stop without ZA2BS844 withoutReferences XACA671 XACA6714 XACA871Empty enclosures type XACANumber of ways 2 3 4 5 6 8 12References XACA02 XACA03 XACA04 XACA05 XACA06 XACA08 XACA122/30Other versions: please consult our Customer Care Centre.


Separate components (for mounting in enclosures XACA)Mushroom head, latching, trigger action (1)turn to release Ø 40 ZA2BS844Ø 30ZA2BS83412Mushroom head, latching, trigger action (1)key release Ø 40 ZA2BS944Ø 30ZA2BS9343Booted operatorswhiteblackXACA9411XACA94124Selector switch2 pos. stay put ZA2BD23 pos. stay put ZA2BD3Key switchkey n° 455 2 pos. stay put ZA2BG43 pos. stay put ZA2BG55Pilot light headswhitegreenredyellowPilot light bodiesdirect supplydirect supply, through resistorBlanking plugwith seal andfixing nutZA2BV01ZA2BV03ZA2BV04ZA2BV05ZB2BV006ZB2BV007ZB2SZ367Isolating switch, slow break, for front mountingEmergency stop NC+NC+NC XENT1192with positive opening operationDouble blocks latching, slow breakSingle-speed NO+NOXENG3781Single-speed NO+NCXENG3791Contact blocks (for mounting in enclosure base)NOXACS101NC+NOXACS1058Contacts blocks for XACA941pContact blocksProtective guard (for base mounted units)Single-speed NC+NOXENG1491Single-speed NOZB2BE101For selector switchXACA982/9832-speed NC+NO+NOXENG1191Single-speed NCZB2BE102For emergency stop pushbutton XACA984Legends, 30 x 40 mm With symbols conforming to NF E 52-124 With text9References ZB2BY4901 ZB2BY4903 ZB2BY4907 ZB2BY4909 ZB2BY4913 ZB2BY4915 ZB2BY4930 ZB2BY2303 ZB2BY2304blankwhite or yellowbackgroundReferences ZB2BY2904 ZB2BY2906 ZB2BY2910 ZB2BY2912 ZB2BY2916 ZB2BY2918 ZB2BY2931 ZB2BY1W140(1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850, Machinery directive 2006/42/EC and standardEN/IEC 60947-5-5.10Other versions: please consult our Customer Care Centre.2/31


MagelisSmall PanelsMagelis STO/STUwith graphic screen1TypeCharacteristics234Display LCD screen size / Resolution 3.4” / monochrome (200 X 80 pixels)Type Green, orange, red White, pink, red Green, orange, redFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, fl ashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 RJ45 (RS 232 - RS 485) 1 Terminal Block RS232Networks – – –Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen ZelioBradley), Siemens (Simatic), Uni-TE, Modbus, Modbus TCPDevelopment softwareVijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7) or Vijeo Designer Limited EditionDimensions W x D x H (mm) 116,5 x 38,5 x 77,5Compatibility with PLCs«Twido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, ZelioModicon M340»«Compact Flash» card slotNoUSB port1 Host type A + 1 Device type miniBBuilt-in Ethernet TCP/IPNoSupply voltage24 VDCReferences HMISTO511 HMISTO512 HMISTO5015678910TypeCharacteristicsDisplay LCD screen size / Resolution 3.5” / QVGA (320 X 240 pixels) 5.7” / QVGA (320 X 240 pixels)TypeTFT 65 536 coloursFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, fl ashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 RJ45 (RS 232 - RS 485)NetworksEthernet, IEEE 802.3, 10/100 BASE-T, RJ45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic),Uni-TE, Modbus, Modbus TCPDevelopment softwareVijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7) or Vijeo Designer Limited EditionDimensions W x D x H (mm) Front: 98 x 16 x 81 Front: 163 x 17.5 x 129.5Rear : 118 x 30 x 98Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotNoUSB port1 Host type A + 1 Device type miniBBuilt-in Ethernet TCP/IP Yes YesSupply voltage24 VDCReferences HMISTU655 HMISTU8552/32Other versions: please consult our Customer Care Centre.


MagelisSmall PanelMagelis XBT Nwith matrix, semi-graphic screen (1)1TypeCharacteristicsDisplay Capacity 2 lines, 20 characters 1 to 4 lines, 5 to 20 charactersType Back-lit LCD Back-lit LCDgreen3 coloursgreen, orange, redData entryVia keypad with 8 keys (4 customizable keys)Function Representation of variables Alphanumeric Alphanumeric, bargraph, curves, button and lightAlarm log No Yes Yes YesCommunication Serial link 1 RJ45 (RS 232 - RS 485) 1 Sub-D25 (RS 232 - RS 485) + 1 miniDin RS232 (2)Downloadable protocols Uni-TE, Modbus Master Uni-TE, Modbus Master, Siemens,Rockwell,Omron, Mitsubishi, Zelio (2)Development softwareVijeo Designer Lite (on Windows XP and Vista)Dimensions W x D x H (mm) 132 x 37 x 74Compatibility with PLCsTwido, Modicon TSX Micro,Modicon Premium, Modicon M340Twido, Modicon TSX Micro,Modicon Premium, Modicon Quantum, ModiconMomentum, Modicon M340, Zelio (2)Supply voltages 5 VDC or PLC power supply 24 VDCReferences XBTN200 XBTN400 XBTN410 XBTN401(1) Except XBTN200: alphanumeric screen.(2) For XBTN401 onlyMagelis XBT Nwith matrix, semi-graphic screen, dedicated23456TypeCharacteristicsDisplay Capacity 1 to 4 lines, 5 to 20 charactersType Back-lit LCD Back-lit LCDgreen3 colours (green, orange, red)Data entryVia keypad with 8 keysFunction Representation of variables Alphanumeric, bargraph, curves, button and lightAlarm logYesCommunication Serial link 1 Sub-D25 1 miniDin RS232 + 1 Sub-D25Downloadable protocols Modbus ZelioDevelopment softwareVijeo Designer Lite (on Windows XP and Vista)Dimensions W x D x H (mm) 132 x 37 x 74Compatibility with PLCsMotor starterTesys Model UZelio(including connection cable)Supply voltages24 VDCReferences XBTNU400 XBTNSR2 (3)(3) Including : 1 XBTN401 + 1 cable SR2CBL08 for Zelio78910Other versions: please consult our Customer Care Centre.2/33


MagelisSmall PanelMagelis XBT Rwith matrix, semi-graphic screen (1)1TypeCharacteristics234Display Capacity 4 lines, 20 charactersTypeBack-lit LCDgreenBack-lit LCD, 3 coloursgreen, orange, redData entryVia keypad with 20 keys (12 customizable keys)Function Representation of variables Alphanumeric, bargraph, curves, button and lightAlarm log Yes Yes YesCommunication Serial link 1 RJ45 (RS 232 - RS 485) 1 Sub-D25 (RS 232 - RS 485) + 1 miniDin (RS232)Downloadable protocols Uni-TE, Modbus Master Uni-TE,Modbus Master/Slave (1), Siemens, Rockwell,Omron, Mitsubishi, Zelio (1)Development softwareVijeo Designer Lite (on Windows XP and Vista)Dimensions W x D x H (mm) 137 x 37 x 118Compatibility with PLCsTwido, Modicon TSX Micro,Modicon Premium, Modicon M340Twido, Modicon TSX Micro, Modicon Premium, Modicon Quantum,Modicon Momentum, Modicon M340, Zelio (1)Supply voltages 5 VDC or PLC power supply 24 VDCReferences XBTR400 XBTR410 XBTR411(1) For XBTR411 only5Magelis XBT RTwith semi-graphic and touchscreen6TypeCharacteristics789Display Capacity 10 lines, 33 charactersType Back-lit LCD green Back-lit LCD green, orange, redData entryVia keypad with 12 keys (10 customizable keys) or touchscreenFunctions Representation of variables Alphanumeric, bargraph, curves, button and lightAlarm log Yes YesCommunication Serial link 1 RJ45 (RS 232 - RS 485) + 1 miniDin (RS232) (2)Downloadable protocolsUni-TE, Modbus Master, Siemens, Rockwell,Omron, MitsubishiDevelopment softwareVijeo Designer Lite (on Windows XP and Vista)Dimensions W x D x H (mm) 137 x 37 x 118Compatibility with PLCs Twido, Modicon TSX Micro, Modicon Premium, Modicon M340, Modicon Quantum, Zelio (2)Supply voltages 5 VDC or PLC power supply 24 VDCReferences XBTRT500 XBTRT511(2) For XBTRT511 only102/34Other versions: please consult our Customer Care Centre.


MagelisAdvanced PanelMagelis XBT GTwith 3.8” touchscreen1TypeCharacteristicsDisplay LCD screen size / Resolution 3.8” / QVGAType STN monochrome, amber or red TFT 256 colourFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 RJ45 (RS 232 - RS 485)Networks – Ethernet, IEEE 802.310/100 BASE-T, RJ45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7)Dimensions W x D x H (mm) 118 × 30 × 98Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotNoUSB port Host type A 1 1 1Built-in Ethernet TCP/IP No YesSupply voltage24 VDCReferences XBTGT1105 XBTGT1135 XBTGT1335Magelis XBT GTwith 5.7” touchscreen23456TypeTypeCharacteristicsDisplay LCD screen size / Resolution 5.7” / QVGA 5.7” / VGAType STN Monochrome STN, colour TFT, colour 65536 coloursBluebacklightingBlack and Whitebacklighting4096 colours High brightnessbacklightingFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 Sub-D9 (RS 232/RS 422 - RS 485) + 1 RJ45 (RS 485)Networks – Ethernet, IEEE 802.3 – Ethernet, IEEE 802.3 Ethernet Ethernet, IEEE 802.310/100 BASE-T, RJ45 10/100 BASE-T, RJ45 10/100 BASE-T 10/100 BASE-T, RJ45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCP/IPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7)Dimensions W x D x H (mm) 167.5 x 60 x 135Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340, Modicon Momentum«Compact Flash» card slot No YesUSB port Host type A 1 2Video inNoBuilt-in Ethernet TCP/IP No No Yes No Yes Yes YesSupply voltage24 VDCReferences XBTGT2110 XBTGT2120 XBTGT2130 XBTGT2220 XBTGT2330 XBTGT2930 XBTGT243078910Other versions: please consult our Customer Care Centre.2/35


MagelisAdvanced PanelMagelis XBT GTwith 7.5” and 10.4” touchscreen1TypeCharacteristics2345Display LCD screen size / Resolution 7.5” / VGA 10.4” / VGA 10,4” / SVGAType (colour) STN TFT TFT STN TFT TFT TFTNumber of colours 4096 65536 65536 4096 65536 65536 65536Functions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 Sub-D9 (RS 232/RS 422 - RS 485) + 1 RJ45 (RS 485)Networks Ethernet, IEEE 802.3 10/100 BASE-T, RJ 45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCP/IPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7)Dimensions W x D x H (mm) 215 x 60 x 170 313 x 56 x 239 271 x 57 x 213Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotYesUSB port Host type A 1 1 1 2 2 2 2Video in No No Yes No No Yes NoBuilt-in Ethernet TCP/IPYesSupply voltage24 VDCReferences XBTGT4230 XBTGT4330 XBTGT4340 XBTGT5230 XBTGT5330 XBTGT5340 XBTGT54306Magelis XBT GTwith 12.1” and 15” touchscreen7TypeCharacteristics8910Display LCD screen size / Resolution 12,1” / SVGA 15” / XGAType (colour) TFT TFT TFTNumber of colours 65536 65536 65536Functions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 Sub-D9 (RS 232/RS 422 - RS 485) + 1 RJ45 (RS 485)Networks Ethernet, IEEE 802.3 10/100 BASE-T, RJ 45BASE-T, RJ 45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCP/IPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7)Dimensions W x D x H (mm) 313 x 56 x 239 395 x 60 x 294Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotYesUSB port Host type A 2Video in No Yes YesBuilt-in Ethernet TCP/IPYesSupply voltage24 VDCReferences XBTGT6330 XBTGT6340 XBTGT73402/36Other versions: please consult our Customer Care Centre.


MagelisAdvanced PanelMagelis XBT GKwith touchscreen and keypad1TypeCharacteristicsDisplay Screen size / Resolution 5.7” / QVGA 10.4” / VGATypeSTN monochromeblack and whiteTFT Colour65536 coloursData entry Soft function keys with LED 14 18Static function keys with LED 10 + legends 12 + legendsService keys / Alphanumeric keys 8 / 12Touchscreen and industrial pointer YesFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurvesYes, with logAlarm logsYesCommunication Serial link 1 Sub-D9 (RS 232/RS 422 - RS 485) + 1 RJ45 (RS 485)Networks – Ethernet, IEEE 802.3 10/100 BASE-T, RJ 45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCP/IPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7)«Compact Flash» card slotYesDimensions W x D x H (mm) 220.3 x 88 x 265 296 x 91 x 332 197 x 92.6 x 147Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340USB port 1 1 2Video in No No NoBuilt-in Ethernet TCP/IP No YesSupply voltage24 VDCReferences XBTGK2120 XBTGK2330 XBTGK5330Magelis XBT GTWwith 8.4”, 12”, 15” touchscreen234567TypeCharacteristicsPre-installed SoftwareOS: Windows XP Embedded, Internet Explorer, Office & Acrobat Reader, .NET, Vijeo Designer Run Time unlimited– Vijeo Citect Web ClientTouchscreen 8.4” LCD TFT 12” LCD TFT 15” LCD TFTResolution SVGA 800 x 600 SVGA 800 x 600 XGA 1024 x 768Font panel ports – 1 x USB 1 x USBProcessor Celeron M @ 600 MHz Celeron M @ 1GHz Celeron M@1GHzRAM 512MB ► 1024MB 512MB ► 1024MB 1024MBStorage CF 2GB expandable to 4GB CF 2GB expandable to 4GB CF 4GBExtension – 1 x PCMCIA slot(for 1 type II card)1 PCMCIA slot (for 1 type III cardor 2 type I cards)Ethernet ports 2 (10/100/1G + 10/100) 2 (10/100/1G + 10/100) 2 (10/100/1G + 10/100)Ports I/O 4 x USB, 2 x RS232 4 x USB, 1 x RS232 4 x USB, 2 x RS232Power supply 24 VDC 24 VDC 24 VDCDimension 230 x 65 x 177 313 x 60 x 239 395 x 65 x 294References XBTGTW450 XBTGTW652 HMIGTW73538910Other versions: please consult our Customer Care Centre.2/37


MagelisAdvanced PanelMagelis XBT GHwith 5.7” touchscreen1234567TypeCharacteristics+ ScreenDisplay screen size / Resolution 5,7” / VGAType (colour)TFTNumber of colours 65 536Data entry Function keys 11 + labelOperaton key1 with LED (validation touchscreen)Safety components Key Switch Yes for ON/OFF3 positions Enable switch Yes, OK signal in intermediate position onlyEmergency stopYes, red with 2 safe contacts and one auxiliary contactFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, fl ashing light, keypadCurves / Alarm historicYes, with log / Yes, incorporatedConnection32-pins connector (communication, alimentation, I/O)Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCP/IPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows XP, Vista and 7)«Compact Flash» card slotYesDimensions W x D x H (mm) 224 x 174 x 87.1USB port 1Supply voltage24 VDCReferenceXBT GH2460+ Cable interface connection with junction boxType of connector2 x 32-pins speed connectorsLength 3 m 5 m 10 mReference XBTZGHL3 XBTZGHL5 XBTZGHL10+ Junction box connection with PLCsCommuncation Serial link 1 SubD9 (RS232 / RS422 - RS 425)Network1 Ethernet RJ45 IEEE 802.3 10/100 T-BASE,Connection 32 pins connector Interface cable 3 or 10 m24 pins screw terminals blocks For alimentation 24 VDC, state of I/O safety componentsReferenceXBTZGJBOXA large number of accessories (cables, memory cards, protective sheets, etc ...) is available for the Advanced panels range.89102/38Other versions: please consult our Customer Care Centre.


MagelisAll in OneHMI ControllersModular HMI ControllerMagelis XBTGT/GK with control function1TypeCharacteristicsDisplay LCD screen size / Resolution 5.7” / QVGA to 10,4” / VGA «5.7” (QVGA/VGA), 7.5” (VGA), 10.4” (VGA/SVGA),12.1” (SVGA), 15” (XGA)»Type STN monochrome or TFT color STN monochrome, STN 4096 colors, TFT 65000colorsFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedControl5 languages IECCommunication Serial link 1 RJ45 (RS 485) + 1 Sub9 (RS 232/RS 422 - RS 485)NetworksEthernet, IEEE 802.3 10/100 BASE-T, RJ45 depending on modelDownloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic),Uni-TE, Modbus, Modbus TCPDevelopment softwareSoMachine (under Windows XP and Vista)Dimensions W x D x H (mm)Depending on modelCompatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotYesUSB port 1 or 2Built-in Ethernet TCP/IPDepending on modelBuilt-in I/ONoExtensionsCANopen module mandatorySupply voltage24 VDCReferences XBTGK2●/53 XBTGT2●/4●/5●/63/7323456Control extension7Type of moduleCharacteristicsReferenceCANopen MasterClass M10 limited 16 slaves, Standard DS301 V4.O2XBTZGCANM8910Other versions: please consult our Customer Care Centre.2/39


MagelisAll in OneHMI ControllersMagelis XBT GCCompact HMI Controller1TypeCharacteristics2345Display LCD screen size / Resolution 3,8” / QVGA 5,7” / QVGAType STN monochrome, amber or red STN monochrome, gray STN 4096 coloursFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedControl 5 languages IECCommunication Serial link – 1 Sub9 (RS 232/RS 422 - RS 485)Networks – – Ethernet, IEEE 802.310/100 BASE-T, RJ45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCPDevelopment softwareSoMachine (on Windows XP and Vista)Dimensions W x D x H (mm) 130 x 76 x 104 207 x 76 x 157Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotNoUSB port Host type A 1 1 1Built-in Ethernet TCP/IP No No YesIntegrated I/O 12I/6O 24 VDC 16I/16O 24 VDCExtensions2 modules TM2or CANopen module3 modules TM2or CANopen moduleSupply voltage24 VDCReferences Source Output XBTGC1100T XBTGC2120T XBTGC2230TSink Output XBTGC1100U XBTGC2120U XBTGC2230U6Type of moduleCharacteristicsReferencesExtensionsCANopen MasterClass M10 limited 16 slaves, Standard DS301 V4.O2XBTZGCCAN78910Type of moduleCharacteristicsDigitals Inputs / Outputs8I24 VDCScrew terminal16I24 VDCScrew terminal16I24 VDCHE1032I24 VDCHE108I120 VACScrew terminal4I 24 VDC4O RelaysScrew terminal16I 24 VDC8O RelaysScrew terminalReferences TM2DDI8DT TM2DDI16DT TM2DDI16DK TM2DDI32DK TM2DAI8DT TM2DMM8DRT TM2DMM24DRFType of moduleCharacteristicsDigitals Inputs / Outputs8O Transistor24 VDCScrew terminal16O Transistor24 VDCHE1032O Transistor24 VDCHE108O Relays230 VAC 30 VDCScrew terminal16O Relays230 VAC 30 VDCScrew terminalReferences Source Output TM2DD08TT TM2DD016TK TM2DD032TK TM2DRA8RT TM2DRA16RTSink Output TM2DD08UT TM2DD016UK TM2DD032UK – –Type of moduleAnalog Inputs / OutputsCharacteristics 2I Current/Voltage 2I Thermocouple 4I Current/VoltageTemperature8I Current/Voltage 8I Temperature 8I PTCReferences TM2AMI2HT TM2AMI2LT TM2AMI4LT TM2AMI8HT TM2ARI8LRJTM2ARI8LTType of moduleAnalog Inputs / OutputsCharacteristics 1O Current/Voltage 2O Voltage 2I Current/Voltage1O Current/Voltage2I Temperature1O Current/VoltageTM2ARI8HT4I Current/Voltage2O Current/VoltageReferences TM2AMO1HT TM2AVO2HT TM2AMM3HT TM2ALM3LT TM2AMM6HT2/40Other versions: please consult our Customer Care Centre.


MagelisAll in OnePC PanelsMagelis Smartwith 8.4”, 12”, 15” touchscreen1Smart 8.4 Smart 12 Smart 15Pre-installed SoftwareOS: Windows XP Embedded, Internet Explorer, Office & Acrobat Reader, .NET– Vijeo Designer Runtime demo, Vijeo Citect Web ClientTouch screen 8.4” LCD TFT 12” LCD TFT 15” LCD TFTResolution SVGA 800x600 SVGA 800x600 XGA 1024x768Front side port – 1 x USB 1 x USBProcessor Celeron M@600MHz Celeron M@1GHz Celeron M@1GHzRAM 512MB ► 1024MB 512MB ► 1024MB 1024MBStorage CF 2GB expandable to 4GB CF 2GB expandable to 4GB CF 4GB Flash Disk 15GBExtension – 1 x PCMCIA slot(for 1 type II card)1 PCMCIA slot (for 1 type III card or 2 type I cards)Ethernet ports 2 (10/100/1G + 10/100) 2 (10/100/1G + 10/100) 2 (10/100/1G + 10/100)I/O ports 4 x USB, 2 x RS 232 4 x USB, RS 232 4 x USB, 2x RS 232Certification UL 508, CSA 142,Marine (1)UL 508, CSA 142 UL508, cUL, UL1604 (Haz-Loc Class 1 Div 2) (1),Marine DNV (1)Dimensions W x D x H (mm) 230 x 65 x 17 313 x 60 x 239 395 x 65 x 294iPC without maintenance License VJDSNRTMPC for Vijeo AC MPCST11NAJ00T MPCST21NAJ20T HMIPSC7AE03 –(Compact Flash disk) iPC without maintenanceunlimited, to be ordered separately. DC MPCST11NDJ00T MPCST21NDJ20T HMIPSC7DE03 –iPC without maintenance License VJDSNRTMPC for Vijeo AC – – – HMIPSF7AP03(Flash disk)iPC without maintenanceunlimited, to be ordered separately. DC – – – HMIPSF7DP03Vijeo Citect Lite 1200 E/S AC – – – HMIPSF7APL3Vijeo Citect Full 500 E/S AC – – – HMIPSF7APF3(1) DC version, onlyMagelis Compact iPCwith 8.4”, 12”, 15” touchscreen23456Compact Compact CompactiPC 8.4” iPC 12” iPC 15”Pre-installed SoftwareWindows XP PRO, Vijeo Designer Run Time DemoTouch screen 8.4” LCD TFT 12” LCD TFT 15” LCD TFTResolution SVGA 800x600 XGA 1024x768 XGA 1024x768Front side port – 1 x USB 1 x USBProcessor Celeron M@1GHz Celeron M@1.5GHz Pentium M@1.6GHzRAM 512MB ► 1024MB 512MB ► 1024MB 512MB ► 2GB 1,5GB ► 2GBDrive devices – – Engraver DVDStorage HDD ≥ 80 GB HDD ≥ 250 GB or Flashdisk 15 GBHDD ≥ 80 GB or Flashdisk 15 GBExtension – 1 PCMCIA slot(for 1 type II card)1 PCMCIA slot (for 1 type III card or 2 type I card)Ethernet ports 2 (10/100/1G + 10/100) 2 (10/100/1G + 10/100) 2 (10/100/1G + 10/100)I/O ports 4 x USB, 2 x RS 232 4 x USB, 1 x RS 232 4 x USB, 4 x RS 232Certification UL508, CSA UL508, CSA UL508, CSA, UL1604 (Haz-Loc Class 1, Div 2)Dimensions W x D x H (mm) 230 x 120 x 177 313 x 100 x 239 395 x 100 x 294General PurposeLicense VJDSNRTMPC for Vijeo AC MPCKT12NAX00N MPCKT22NAX20N MPCKT55NAX20N –(Hard Drive)Designer Run Time ≥ 5.1,unlimited, to be ordered separately. DC – – MPCKT55NDX20N –Heavy Duty AC – MPCKT22MAX20N MPCKT55MAX20N –(Flash disk)SCADA Edition (Vijeo Citect) ACVijeo Citect Lite 1200 I/O – – – MPCKT55MAX20LVijeo Citect Full 500 I/O – – – MPCKT55MAX20V78910Other versions: please consult our Customer Care Centre.2/41


MagelisBOXEmbedded BOX and PC BOXMagelis Smart BOX,Magelis Compact PC BOX1Smart BOXCompact PC BOX2345Pre-installed SoftwareWindows XP PRO, Vijeo Designer Run Time DemoProcessor Celeron M@600MHz Celeron M@1GHzRAM Default ► Max 256MB ► 1024MB 512MB ► 1024MBStorage CF 2 GB HDD ≥ 80 GBDrives – –Extension – 1 x PCIVideo ports 1 x RGB 1 x RGBEthernet ports 2 (10/100/1G + 10/100) 2 (10/100/1G + 10/100)I/O ports 4 x USB, 2 x RS 232 4 x USB, 2 x RS 232Certification UL508, CSA, UL1604 (Haz-Loc Class 1 Div 2),ATEX2-22, Marine DNV (1)UL508, CSAConnection for iDisplay Yes Yesfor Front Panel No NoDimensions W x D x H (mm) 218 x 65 x 165 218 x 115 x 165iPC General Purpose License VJDSNRTMPC for Vijeo AC – MPCKN02NAX00N(Hard Drive)Designer Run Time ≥ 5.1,unlimited, to be ordered separately.iPC without maintenance License VJDSNRTMPC for Vijeo AC MPCSN01NAJ00T (2) –(Compact Flash disk) Designer Run Time ≥ 5.1,unlimited, to be ordered separately. DC MPCSN01NDJ00T –(1) Marine DNV and Atex 2-22 on DC version only(2) With delivered external alimentation adaptatorMagelis Flex PC BOX678910Pre-installed SoftwareProcessorFlex PC BOX FWindows XP PRO, Vijeo Designer Run Time DemoCeleronM1,86GhzCore Duo 2GhzFlex PC BOX HCeleronM1,86GhzCore Duo 2GhzRAM Default ► Max 512MB>2GB 1GB>2GB 2GB 512MB>2GB 1GB>2GB 2GBStorageHDD ≥ 250GB with option RAIDor Flash Disk 15GBHDD ≥ 250GB with option RAIDor Flash Disk 15GBDrives Engraver DVD Engraver DVD Engraver DVDExtension 2PCI 4PCIVideo ports1 x DVI-I (RGB)Ethernet ports 2 (10/100/1 G + 10/100)I/O ports 4 x USB, 4 x RS 232Certification UL508, cUL, UL1604 (Haz-Loc Class 1 Div 2), ATEX2-22 (1)Connection for iDisplay Yesfor Front PanelYesDimensions W x D x H (mm) 243 x 160 x 289 243 x 205 x 289iPC General Purpose License VJDSNRTMPC for Vijeo AC MPCFN02NAX00N MPCFN05NAX00N – MPCHN02NAX00N MPCHN05NAX00N –(Hard Drive)Designer Run Time ≥ 5.1,unlimited, to be ordered separately. DC MPCFN02NDX00N MPCFN05NDX00N – MPCHN02NDX00N MPCHN05NDX00N –Heavy Duty (Flash disk) AC – MPCFN05MAX00N – – MPCHN05MAX00N –Heavy Duty (Flash disk) Vijeo Citect full 500 I/O AC – – MPCFN05MAX00V – – MPCHN05MAX00V(1) Atex 2/22 for DC version only2/42Other versions: please consult our Customer Care Centre.


MagelisFront PanelMagelis iPCTo be connected only with Magelis Flex PC BOX1Front Panel 12” touch & keypad 15” touch & keypad 15” touch 19” touchTouchscreen 12” LCD TFT 15” LCD TFT 15” LCD TFT 19” LCD TFTResolution SVGA 800x600 XGA 1024x768 XGA 1024x768 SXGA 1280x1024Front side port 1 x USB 1 x USB 1 x USB 1 x USBDimensions W x D x H (mm) 420 x 31 x 320 483 x 31 x 365 420 x 31 x 320 460 x 44 x 390References MPCYB20NNN00N MPCYB50NNN00N MPCYT50NNN00N MPCYT90NNN00N234Industrial DisplayMagelis iDisplaywith 15”, 19” touchscreen5615” touch & keypad 15” touch 19” touchTouchscreen 15” LCD TFT 15” LCD TFT 19” LCD TFTResolution XGA 1024x768 XGA 1024x768 SXGA 1280x1024Front side port 1 x USB 1 x USB 1 x USBVideo ports 1 x VGA & 1 x DVI 1 x VGA & 1 x DVI 1 x VGA & 1 x DVITouchscreen ports 1 x USB & 1 x RS 232 1 x USB & 1 x RS 232 1 x USB & 1 x RS 232Power supply 100…240VAC 100…240VAC 100…240VACCertification UL508, CSA UL508, CSA UL508, CSADimensions W x D x H (mm) 483 x 65 x 365 395 x 60 x 294 460 x 65 x 390References MPCNB50NAN00N MPCYT50NAN00N MPCYT90NAN00N78910Other versions: please consult our Customer Care Centre.2/43


Vijeo Designer* Available with Vijeo Designer ≥ 5.0Configuration softwareMagelis STO/STU, XBT GT, GK, GTW, GHMagelis Smart, Compact iPC and PC BOX*1Vijeo Designer configuration software enables creation of automated system control operator dialogue2NavigatorApplicationapplications for Magelis STO/STU, XBT GT, GK, GTW, GH terminals and Smart & Compact iPC andPC BOX. It also enables management of the multimedia functions of XBT GTW and Smart & CompactiPC (video and audio) and offers users of Ethernet terminals and iPC remote access via a Web browser(WEB Gate function).ConfigurationVijeo Designer configuration software enables fast, simple processing of operator dialogue projects34567PropertyInspectorFeedback zoneAnimatedgraphicalobjectslibrarythanks to its ergonomics, developed around 6 configurable windows.It also offers comprehensive application management tools:. Project creation; projects comprising one or several targets (terminal or iPC).. Recipe editor (32 groups of 256 recipes of max. 1024 ingredients).. User action list (eg. script) for application adaptability.. Application variable cross-referencing.. Vectorial graphic library for more attractive graphic screens.. Application block diagram documentation.. Simulation mode for simple design office application testing.. High-performance graphic editor for simple block diagram creation (over 30 animated preconfigured genericobjects).. Support of layers and masks for faster development.. Data sharing (up to 300 variables on 8 terminals).. Management of 40 alphabets (including simplified Chinese, Korean, Arabic and Hebrew) with theopportunity to have 15 languages per application and dynamic change.. Programmable controller database sharing (Unity Pro, PL7, Concept, TwidoSoft, ProWORX, ModSoft),process variables or operators actions. Advanced traceability function (periodic, at event or on request).. Project backup on terminal for simple maintenance.. User-friendly data recovery tool.. Support of standard USB peripherals (USB key up to 4 GB).. Support of external USB keyboards and mice.. Integration with Schneider Electric equipment (buffer diag., variables access, Unity DDT and unlocatedvariables.). Event-triggered e-mail funtion. Over 35 third party protocols. Multilingual software : English, French, German, Italian, Spanish, Portuguese and Simplified Chinese.. Printing functionThe Vijeo Designer Limited Edition, downloadable or free access allows you to configure the MagelisSTO/STU.89Industrial intelligence option: Intelligent Data ServiceIntelligent Data Service (IDS) is an extension of Vijeo Designer for the PC (Magelis or standard PC)which supports the implementation of control solutions for one or a number of terminals (up to 8). Thisextension offers total traceability. Both process variables and operator actions are tracked so that theright decisions can be made at the right time (Industrial Business Intelligence).Powerful Data can be collected from multiple terminals via Ethernet without impairing HMI reactiontimes.Flexible Various storage methods are supported, CSV file can be read directly in MS Excel, recording inuser-defined format in an SQL database or secure IDV (Intelligent Data Vault) files to ensure compatibilitywith the requirements of 21 CFR Part 11.102/44Other versions: please consult our Customer Care Centre.


Vijeo Designer LiteConfiguration softwareMagelis XBT N, R, RT1Vijeo Designer Lite configuration software enables the creation of simple operator dialogue applicationson Magelis XBT N, R and RT Small Panel ranges.It also enables transparent recovery of all applications for Magelis XBT N and R produced using itspredecessor: XBT L1000.For simplified installation and improved consistency, Vijeo Designer Lite retains the main characteristicsof Vijeo Designer software (ergonomics, interface ...) which has become the reference in the HMI field.2ConfigurationVijeo Designer Lite software enables fast and easy creation of different types of pages (application page,alarm pages, help pages...) and the installation of navigation between pages.It offers:- Graphic objects developed for Magelis XBT RT (bar charts, trend curves...)- Character fonts Byzantine, simplified Chinese, Cyrillic, Japanese- Project reports- Application simulation on PC- Six languages : English, French, German, Italian, Spanish and Chinese.34Selection guide for Vijeo Designer LiteNumber of licenses Composition References5Single (1) Without cable VJDSNDTMSVppMWith USB cableVJDSUDTMSVppMSoftware is delivered on CD-ROM and can be executed under Windows 2000, XP and Vista.pp represents version number.These references are downlodable on Schneider-Electric.com6Selection guide for Vijeo DesignerNumber of licences Composition ReferencesSingle (1) Without cable VJDSNDTGSVppMWith USB cableVJDSUDTGAVppMGroup (3) Without cable VJDGNDTGSVppMTeam (10) Without cable VJDTNDTGSVppMFacility (Unlimited) Without cable VJDFNDTGSVppMThe software is supplied on DVD and runs under Windows XP, Windows Vista and Windows 7.pp represent the version number.Runtime pour Magelis iPC Composition ReferencesSingle (1) Without cable VJDSNRTMPC789IDS Single (1) Without cable VJDSNTRCKVppM10Other versions: please consult our Customer Care Centre.2/45


ZelioDesigned for hard-wired logic controlapplications to complement PLCs whenperforming simple functions such ascounting, measurement and control,the single-function products in theZelio range of relays offer optimum results.The challenges of industrial competitivenessmean that control systems are nowpresent in all fields of application. The Zeliorange of innovative, effective and reliablerelays supports the Twido programmablecontrollers and Modicon automationplatforms. With Zelio you optimise yourprocesses, reduce your energy bills andenhance the safety of personnel andequipment.ModiconModicon automation platforms improveperformance, quality and profitability foryour installations, production sites andmachines. Conforming to internationalstandards and simple to set up, the Modiconrange integrates seamlessly into any controlsystem.


AutomationThis document is a selection ofthe top selling products.1RelaysProgrammable controllersElectromechanical plug-in relays, Zelio Relay .................................................................. 3/2 to 3/4Solid-state relays, Zelio Relay .................................................................................................... 3/5Control and measurement relays, Zelio Control ............................................................ 3/6 to 3/10Counters, Zelio Count ...............................................................................................................3/11Timing relays, Zelio Time .............................................................................................. 3/12 to 3/13Analog interface, Zelio analog ...................................................................................... 3/14 to 3/15Smart relays, Zelio Logic .............................................................................................. 3/16 to 3/17Programmable controllers, Twido ................................................................................. 3/18 to 3/21Programmable Automation ControllersProgrammable Automation Controllers, Modicon M340 ............................................... 3/22 to 3/29Programmable Automation Controllers, Modicon Premium ......................................... 3/30 to 3/37Programmable Automation Controllers, Modicon Quantum ........................................ 3/38 to 3/4523456SoftwareProgramming software, Zelio Soft 2 ......................................................................................... 3/17Programming software, Twido Suite ......................................................................................... 3/20Configuration software, Unity Pro ................................................................................. 3/46 to 3/47Programming software, PL7, Concept, ProWORX32 .................................................. 3/48 to 3/49SCADA software, Vijeo Citect .................................................................................................. 3/50Reporting software, Vijeo Historian ......................................................................................... 3/51789103/1


Zelio RelayElectromechanical plug-in relaysInterface and miniature relays12345Type of relay Interface relays Miniature relaysRSBRXMContact characteristicsThermal current Ith in A (temperature ≤ 55°C) 8 12 16 12 10 6 3Number of contacts 2 “C/O” 1 “C/O” 1 “C/O” 2 “C/O” 3 “C/O” 4 “C/O” 4 “C/O”Contact material AgNi AgNi AgNi AgNi AgNi AgNi AgAuSwitching voltage, min. / max. 5 / 250 VAC/DC 12 / 250 VAC/DCSwitching capacity, min. / max. (mA / VA) 5 / 2000 5 / 3000 5 / 4000 10 / 3000 10 / 2500 10 / 1500 2 / 1500Coil characteristicsAverage consumption, inrush, 0.75 VA / 0.45 W 1.2 VA / 0.9 WPermissible voltage variation 0.8/0.85…1.1 Un (50/ 60Hz or =) 0.8…1.1 Un (50 / 60Hz or =)References (1) (1) (1) (2) (2) (2)Coil supply voltage 6 VDC RSB2A080RD RSB1A120RD RSB1A160RD – – – –on DC 12 VDC RSB2A080JD RSB1A120JD RSB1A160JD RXM2AB2JD RXM3AB2JD RXM4AB2JD RXM4GB2JD24 VDC RSB2A080BD RSB1A120BD RSB1A160BD RXM2AB2BD RXM3AB2BD RXM4AB2BD RXM4GB2BD48 VDC RSB2A080ED RSB1A120ED RSB1A160ED RXM2AB2ED RXM3AB2ED RXM4AB2ED RXM4GB2ED60 VDC RSB2A080ND RSB1A120ND RSB1A160ND – – – –110 VDC RSB2A080FD RSB1A120FD RSB1A160FD RXM2AB2FD RXM3AB2ED RXM4AB2ED RXM4GB2EDCoil supply voltage 24 VAC RSB2A080B7 RSB1A120B7 RSB1A160B7 RXM2AB2B7 RXM3AB2B7 RXM4AB2B7 RXM4GB2B7on AC 48 VAC RSB2A080E7 RSB1A120E7 RSB1A160E7 RXM2AB2E7 RXM3AB2E7 RXM4AB2E7 RXM4GB2E7120 VAC RSB2A080F7 RSB1A120F7 RSB1A160F7 RXM2AB2F7 RXM3AB2F7 RXM4AB2F7 RXM4GB2F7220 VAC RSB2A080M7 RSB1A120M7 RSB1A160M7 – – – –230 VAC RSB2A080P7 RSB1A120P7 RSB1A160P7 RXM2AB2P7 RXM3AB2P7 RXM4AB2P7 RXM4GB2P7240 VAC RSB2A080U7 RSB1A120U7 RSB1A160U7 – – – RXM4GB2U7678910Sockets for relaysType of socket For interface relays RSB For miniature relays RXMMixed input/output type sockets with location for protection module– – – RXZE2M114(5) – RXZE2M114 RXZE2M114– – – RXZE2M114M(5) – RXZE2M114M RXZE2M114MSeparate input/output type sockets with location for protection moduleRSZE1S48M RSZE1S35M RSZE1S48M(3) RXZE2S108M RXZE2S111M RXZE2S114M RXZE2S114MProtection modulesDiode 6…230 VDC RZM040W RXM040WRC circuit 24…60 VAC RZM041BN7 RXM041BN7110…240 VAC RZM041FU7 RXM041FU7Varistor 6…24 VDC or AC RZM021RB (6) RXM021RB24…60 VDC or AC RZM021BN (6) RXM021BN110…230 VDC or AC RZM021FP (6) RXM021FP24 VDC or AC – –240 VDC or AC – –Multifunction timer module 24…230 VDC or AC – –AccessoriesPlastic maintaining clamp RSZR215 RXZR335Metal maintaining clamp – RXZ400Label for socket RSZL300 RXZL420 (except RXZE2M114)Bus jumper 2 poles – RXZS2DIN rail adapter – RXZE2DAPanel mounting adapter – RXZE2FA(1) References for relays without socket, for relays with socket, add the letter S to the end of the selected reference. (Example: RSB2A080B7 becomes RSB2A080B7S).(2) References for relays with LED, for relays without LED, replace the number 1 in the reference by 2. (Example: RXM2AB2JD becomes RXM2AB1JD)(3) To use RSB 1A160 pp relay with socket, terminals must be interconnected3/2Other versions: please consult our Customer Care Centre.


Universal and power relays1Universal relaysPower relaysRUM RPM RPFCylindricsFaston10 10 3 10 10 15 15 15 15 30 (4) 30 (4)2 “C/O” 3 “C/O” 3 “C/O” 2 “C/O” 3 “C/O” 1 “C/O” 2 “C/O” 3 “C/O” 4 “C/O” 2 “N/O” 2 “C/O”AgNi AgNi AgAu AgNi AgNi AgNi AgNi AgNi AgNi AgSnO 2AgSnO 212 / 250 VAC/DC 12 / 250 VAC/DC 12 / 250 VAC/DC10 / 2500 10 / 2500 3 / 750 10 / 2500 10 / 2500 100 / 3750 100 / 3750 100 / 3750 100 / 3750 100 / 7200 100 / 72002…3 VA / 1.4 W 0.9 VA / 0.7 W 1.2 VA / 0.9 W 1.5 VA / 1.7 W 1.5 VA / 2 W 4 VA / 1.7 W23(2) (2) – (2) (2) (2) (2) (2) (2) – –– – – – – – – – – – –RUMC2AB2JD RUMC3AB2JD – RUMF2AB2JD RUMF3AB2JD RPM12JD RPM22JD RPM32JD RPM42JD RPF2AJD RPF2BJDRUMC2AB2BD RUMC3AB2BD RUMC3GB2BD RUMF2AB2BD RUMF3AB2BD RPM12BD RPM22BD RPM32BD RPM42BD RPF2ABD RPF2BBDRUMC2AB2ED RUMC3AB2ED RUMC3GB2ED RUMF2AB2ED RUMF3AB2ED RPM12ED RPM22ED RPM32ED RPM42ED – –– – – – – – – – – – –RUMC2AB2FD RUMC3AB2FD – RUMF2AB2FD RUMF3AB2FD RPM12FD RPM22FD RPM32FD RPM42FD RPF2AFD RPF2BFDRUMC2AB2B7 RUMC3AB2B7 RUMC3GB2B7 RUMF2AB2B7 RUMF3AB2B7 RPM12B7 RPM22B7 RPM32B7 RPM42B7 RPF2AB7 RPF2BB7RUMC2AB2E7 RUMC3AB2E7 RUMC3GB2E7 RUMF2AB2E7 RUMF3AB2E7 RPM12E7 RPM22E7 RPM32E7 RPM42E7 – –RUMC2AB2F7 RUMC3AB2F7 RUMC3GB2F7 RUMF2AB2F7 RUMF3AB2F7 RPM12F7 RPM22F7 RPM32F7 RPM42F7 RPF2AF7 RPF2BF7– – – – – – – – – – –RUMC2AB2P7 RUMC3AB2P7 RUMC3GB2P7 RUMF2AB2P7 RUMF3AB2P7 RPM12P7 RPM22P7 RPM32P7 RPM42P7 RPF2AP7 RPF2BP7– – – – – – – – – – –456For universal relays RUM For power relays RPM For power relays RPFRUZC2M RUZC3M RUZC3M – – RPZF1 RPZF2 RPZF3 RPZF4 –– – – – – – – – – –RUZSC2M RUZSC3M RUZSC3M RUZSF3M RUZSF3M – – – – –1 and 2 poles 3 and 4 polesRUW240BD RXM040W RUW240BD –– RXM041BN7 – –RUW241P7 RXM041FU7 RUW241P7 –– RXM021RB – –– RXM021BN – –– RXM021FP – –RUW242B7 RUW242B7 – –RUW242P7 – RUW242P7 –RUW101MW – RUW101MW –– – –RUZC200 RPZF1 (for 1 pole relays) –RUZL420 – –RUZS2 – –– RPZ1DA RXZE2DA RPZ3DA RPZ4DA –– RPZ1FA RXZE2FA RPZ3FA RPZ4FA –(4) 30A with 13 mm space between relays; 25 A when relay mounting side by side(5) Max 10 A operating(6) With LED78910Other versions: please consult our Customer Care Centre.3/3


Zelio RelayElectromechanical plug-in relaysRSL relays mounted on sockets1234Type of relayPre-assembled equipped with LED and protection circuitSold in lots of 10Contact characteristicsThermal current Ith in A 6Number of contacts1 C/OContact materialAgSnO2Switching voltage, min/max12 / 300 V AC/DCSwitching capacity min/max (mA /VA) 100 / 1500Coil characteristicsAverage consumption, inrush0.17 Wpermissible voltage variation -10% / +15%Socket connexion Screw connector Spring terminalSocket supply voltage Coil supply voltageReferences 12 V AC/DC 12 V DC RSL1PVJU RSL1PRJU24 V AC/DC 24 V DC RSL1PVBU RSL1PRBU48 V AC/DC 48 V DC RSL1PVEU RSL1PREU110 V AC/DC 60 V DC RSL1PVFU RSL1PRFU230 V AC/DC 60 V DC RSL1PVPU RSL1PRPU5RSL relays67Type of relayRelay for customer assemblySold in lots of 10Number of contacts1 C/OCoil supply voltageReferences 12 V DC RSL1AB4JD24 V DC RSL1AB4BD48 V DC RSL1AB4ED60 V DC RSL1AB4ND8Sockets910Type of socketSockets for customer assembly with LED and protection circuitSold in lots of 10Socket connection Screw connector Spring terminalSocket supply voltageReferences 12 and 24 V AC/DC RSLZVA1 RSLZRA148 and 60 V AC/DC RSLZVA2 RSLZRA2110 V AC/DC RSLZVA3 RSLZRA3230 V AC/DC RSLZVA4 RSLZRA43/4Other versions: please consult our Customer Care Centre.


Zelio RelaySolid-state relaysSSRP relays1Type of relayPanel mountedwithout heat sink and thermal interfaceContact characteristicsThermal current Ith in A 10 25 50 75 90 125Number of contacts1 NOType if switchingZero voltage switchingOutputSPST contactConnectionScrew connectorControl voltage range 3…32 V DC 4…32 V DCOperating voltage 24…280 VAC 48…530 V AC 48…660 V ACReferences SSRPCDS10A1 SSRPCDS25A1 SSRPCDS50A1 SSRPCDS75A2 SSRPCDS90A3 SSRPCDS125A323Control voltage range90…280 V ACOperating voltage 24…280 VAC 80…530 V AC 48…660 V ACReferences SSRPP8S10A1 SSRPP8S25A1 SSRPP8S50A1 SSRPP8S75A2 SSRPP8S90A3 SSRPP8S125A34SSRD relays5Type of relayRail DIN mountedWith integrated heat sinkContact characteristicsThermal current Ith in A 10 20 30 45Number of contacts1 NOType if switchingZero voltage switchingOutputSPST contactConnectionScrew connectorControl voltage range 4…32 V DC 3…32 V DCOperating voltage24…280 VACReferences SSRDCDS10A1 SSRDCDS20A1 SSRDCDS30A1 SSRDCDS45A1Control voltage range 90…280 V AC 90…140 V ACOperating voltage24…280 VACReferences SSRDP8S10A1 SSRDP8S20A1 SSRDP8S30A1 SSRDP8S45A1678Accessories9Type of accessory Heat sink Thermal interface10For relaySSRPReferences SSRAH1 SSRAT1Other versions: please consult our Customer Care Centre.3/5


Zelio ControlRelays3-phase monitoring relays12Functionpresence of phase+phase sequence+phase sequence, +regeneration+phase unbalance, +under/over voltageMonitoring voltage range 208…480 VAC 208…440 VAC 208…480 VAC 220 … 440 VACOutputs 1 C/O 2 C/O 1 C/O 2 C/OReferences RM17TG00 RM17TG20 RM17TE00 RM35TF303456Functionpresence of phase+under/over voltage+presence of neutral+under/over voltageMonitoring voltage range 208…480 VAC 220…480 VAC 120…277 VAC (phase-neutral)Outputs 1 C/O 2 C/O 2 C/OReferences RM17UB310 RM35UB330 RM35UB3N307Level / Speed monitoring relays8910Function Conductive liquid Non-conductive material Over/underlevel monitoring level monitoring Speed monitoringPower supply24…240 VAC/DCMonitoring range 0,25…5 KΩ Input of sensor : Interval between pulses:5…100 KΩ Contact / PNP / NPN 0.05…0.5 s, 0.1…1 s, 0.5…5 s0,05…1 MΩ1…10 s, 0.1…1 mn, 0.5…5 mn1…10 mnOutput 2 C/O 1 C/O 1 C/OReference RM35LM33MW RM35LV14MW RM35S0MW3/6Other versions: please consult our Customer Care Centre.


Current / Voltage /Frequency monitoring relays1FunctionVoltage MonitoringUnder or Over VoltagePower Supply24…240 VAC/DC 50/60HzMonitoring range 0.05…0.5 V 1…10 V 15…150 V0.3…3 V 5…50 V 30…300 V0.5…5 V 10…100 V 60…600 VOutputs 2 C/O 2 C/O 2 C/OReferences RM35UA11MW RM35UA12MW RM35UA13MW234FunctionVoltage MonitoringUnder or Over VoltageUnder and Over VoltagePower Supply self powered self poweredMonitoring range 9…15 VDC 20…80 VAC/DC 65…260 VAC/DC 20…80 VAC/DC 65…260 VAC/DC5Outputs 1 C/O 1 C/O 1 C/O 1 C/O 1 C/OReferences RM17UAS14 RM17UAS16 RM17UAS15 RM17UBE16 RM17UBE15678Function Current Monitoring Frequency Monitoringover curent over or under currentOver or under frequencyPower supply 24…240 VAC/DC 24…240 VAC/DC 50/60 Hz 120…277 VAC 50/60 HzMonitoring range 2…20 A 2…20 mA 0.15…1.5 A 50 Hz ± 10 Hzbuilt-in CT 10…100 mA 0.5…5 A or50…500 mA 1.5…15 A 60 Hz ± 10HzOutput 1 C/O 2 C/O 2 C/O 2 C/OReference RM17JC00MW RM35JA31MW RM35JA32MW RM35HZ21FM910Other versions: please consult our Customer Care Centre.3/7


Zelio ControlRelaysLift / Pump / Motor monitoring relays123FunctionLift motor room temperature monitoring+phase presence+phase sequencePower supply24…240 VAC/DC 50/60HzMonitoring range input PT100 3 wires 208…480 VAC 50/60HzUnder -1…+11 °Cinput PT100 3 wiresOver +34…+46 °C Under -1…+11 °COver +34…+46 °COutput 1 C/O 2 NO 2 C/OReference RM35ATL0MW RM35ATR5MW RM35ATW5MW456Function Pump protection Motor ProtectionCurrent monitor+3 phase monitorWinding Temperature monitor+3 phase monitorPower supply self powered 24…240 VAC/DC(single phase :230 VAC 50/60 Hz)Monitoring range Current: 0.1…10 A Winding Temperature: PTC sensorVoltage (three phase):Three phase voltage: 208…480 VAC 50/60Hz208…480 VAC 50/60HzOutput 1 C/O 2 NO 2 NOReference RM35BA10 RM35TM50MW RM35TM250MW789103/8Other versions: please consult our Customer Care Centre.


Control relays for 3-phase supplies1FunctionRotational direction and presence of phases+ Undervoltage + Over and undervoltage + AsymmetryAdjustable time delay without without 0.1…10 s 0.1…10 s fixed, 0.5 s 0.1…10 sSupply voltage 220…440V 380…440V 400V 380…440V 380…440V 380…440VOutput 2 C/O 2 C/O 2 C/O 2 C/O 1 C/O 2 C/OReferences RM4TG20 RM4TU02 RM4TR34 (1) RM4TR32 (2) RM4TA02 RM4TA32(1) Relay with fixed voltage thresholds.(2) Relay with adjustable voltage thresholds.Current and voltage measurement relays23(3) Basic reference. To be completed with the lettersindicating the required voltage, as shown below:Voltage VAC, 50/60 Hz VDC24…240 V MW MW110…130 V F –220…240 V M –380…415 V Q –FunctionDetection ofover and undercurrentover and undercurrentMeasuring range 3…30 mA 0.3…1.5 A 0.05 …0.5 V 1…10 V 30…300 V 180…270 V10…100 mA 1…5 A 0.3 …3 V 5…50 V 50…500 V0.1…1 A 3…15 A 0.5…5 V 10…100 VAdjustable time delay 0.05…30 s 0.05…30 s 0.05…30 s 0.05…30 s 0.05…30 s 0.1…10 sOutput 2 C/O 2 C/O 2 C/O 2 C/O 2 C/O 2 C/OReferences RM4JA31•• (3) RM4JA32•• (3) RM4UA31•• (3) RM4UA32•• (3) RM4UA33•• (3) RM4UB35456(4) Basic reference. To be completed with the lettersindicating the required voltage, as shown below:RM4-LG01 RM4-LA32Voltage VAC, 50/60 Hz VAC, 50/60 Hz VDC24 V B B –24…240 V – MW MW110…130 V F F –220…240 V M M –380…415 V Q Q –Control relaysLiquid level control relaysEmpty or fill78Sensitivity scale 5 ... 100 kΩ 0.25 ... 5 kΩ2.5 ... 50 kΩ25 ... 500 kΩTime delay without adjustable, 0.1 to 10 sOutput 1 C/O 2 C/OReferences RM4LG01• (4) RM4LA32•• (4)Liquid level control probe typeMeasuring electrode andreference electrode1 simple stainless steel electrodein PVC protective casingMounting suspended suspendedMaximum operating temperature 100°C 100°CReferences LA9RM201 RM79696043910Other versions: please consult our Customer Care Centre.3/9


Zelio ControlMeasurement and control relaysREG temperature control relays1Type of relaySize 24 x 48 mm - 1/32 DIN23Input type Thermocouple PT100 probe Voltage/Current 1...5 V / 4…20 mAIntegrated functionsHysteresis, PID, auto-tuning, fuzzy logic, rampe 8 steps, automatic operating modeAlarm output – 1 – –Communication ModBus – ModBus ModBusSupply voltage 100...240 VAC 24 V AC/DC 100...240 VAC 24 V AC/DCReferences Number/Output type 1/relay REG24PTP1RHU REG24PTP1ARHU REG24PTP1RLU REG24PUJ1RHU REG24PUJ1RLU1/solid-state REG24PTP1LHU REG24PTP1ALHU REG24PTP1LLU REG24PUJ1LHU REG24PUJ1LLU1/4-20 mA REG24PTP1JHU – REG24PTP1JLU – –4567Type of relayFormat 48 x 48 mm - 1/16 DINInput typeUniversalIntegrated functionsHysteresis, PID, auto-tuning, fuzzy logic, rampe 16 steps, automatic and manual operating modeAlarm output 2Communication ModBus – ModBusSupply voltage 100...240 VAC 24 V AC/DCReferences Number/Output type 1/relay REG48PUN1RHU REG48PUNL1ARHU REG48PUN1RLU2/relay REG48PUN2RHU – REG48PUN2RLU1/solid-state REG48PUN1LHU REG48PUNL1LHU REG48PUN1LLU1 + 1 solid-state REG48PUN2RLHU – REG48PUN2RLLU1/4-20 mA REG48PUN1JHU – REG48PUN1JLU1/solid-state + 1/4-20 mA REG48PUN2LJHU – REG48PUN2LJLU8Type of relaySize 96 x 48 mm - 1/8 DIN910Input typeUniversalIntegrated functionsHysteresis, PID, auto-tuning, fuzzy logic, rampe 16 steps, automatic and manual operating modeAlarm output 3Communication ModBus – ModBusSupply voltage 100...240 VAC 24 V AC/DCReferences Number/Output type 1/relay REG96PUN1RHU REG96PUNL1RHU REG96PUN1RLU2/relay REG96PUN2RHU – REG96PUN2RLU1/solid-state REG96PUN1LHU REG96PUNL1LHU REG96PUN1LLU1 + 1 solid-state REG96PUN2RLHU – REG96PUN2RLLU1/4-20 mA REG96PUN1JHU – REG96PUN1JLU1/solid-state + 1/4-20 mA REG96PUN2LJHU – REG96PUN2LJLU3/10Other versions: please consult our Customer Care Centre.


Zelio CountCountersMultifunction counters1Display Mechanical LCDSupply voltage 24 VDC BatteryNumber of digits displayed 5 6 6 8 8Counting frequency 20 Hz 10 Hz 25 Hz 25 Hz 7.5 kHzType of zero reset Manual Without Manual Without Manual (1)Front face dimensions, W x H 41.5 x 31 mm 30 x 20 mm 60 x 50 mm 60 x 50 mm 48 x 24 mmReferences XBKT50000U10M XBKT60000U00M XBKT60000U10M XBKT80000U00M XBKT81030U33E(1) With electrical interlocking.23Compteurs horaires4Display Mechanical LCD5Supply voltage 24 VAC 230 VAC BatteryNumber of digits / display 7 (99,999.99 h) 7 (99,999.99 h) 8 (999,999.99 h)Supply frequency 50 Hz 50 Hz Mode: 1/100 hourType of zero reset Without Without Manual (1)Front face dimensions, W x H 48 x 48 mm 48 x 48 mm 48 x 24 mmReferences XBKH70000004M XBKH70000002M XBKH81000033E67Totalisers8Display LCD LEDNumber of digits displayed 6Counting frequency5 kHzType of resetManual, electric and automaticnFront face dimensions, W x H48 x 48 mmPreselection number 1 2 1 2References Supply voltage 24 VDC XBKP61130G30E XBKP61230G30E XBKP62130G30E XBKP62230G30E115 VAC XBKP61130G31E XBKP61230G31E – –230 VAC XBKP61130G32E XBKP61230G32E XBKP62130G32E XBKP62230G32E910Other versions: please consult our Customer Care Centre.3/11


Zelio TimeTiming relaysModular timers123Type of modular timerOn-delayMultifunctionwidth 17.5 mm, relay outputExternal control no – –Supply voltage 24 VDC - 24 ...240 VAC 24 VDC - 24 ...240 VAC 12 ... 240VAC/DCTiming range 0.1 s…100 h 0.1 s…100 h 0.1 s…10 h 0.1 s…100 hOutput 1 C/O 1 C/O 1 C/O 1 C/OReferences RE11RAMU RE11RMMU (1) RE11RMEMU (2) RE11RMMW (1)(1) Multifunction: On-delay, Off-delay, Totaliser, Symmetrical flashing, Chronometer, Pulse on energisation, Pulse output, Timing after closing/opening of control contact.(2) Multifunction: On-delay, Off-delay, Totaliser, Symmetrical flashing, Chronometer, Pulse on energisation.45Type of modular timerwidth 17.5 mm, relay outputAsymmetricalflashingPulse onenergisationOff delayTiming onimpulseExternal control – – – –Supply voltage 24 VDC - 24…240 VAC 24 VDC - 24…240 VAC 24 VDC - 24…240 VAC 24 VDC - 24…240 VACTiming range 0.1 s…100 h 0.1 s…100 h 0.1 s…100 h 0.1 s…100 hOutput 1 C/O 1 C/O 1 C/O 1 C/OReferences RE11RLMU RE11RHMU RE11RCMU RE11RBMU678Type of modular timerwidth 17.5 mm, solid-state outputOn-delay Off-delay Multifunction (3)Supply voltage 24…240 VAC/DC 24…240 VAC 24…240 VACTiming range 0.1 s…100 h 0.1 s…100 h 0.1 s…100 hOutput solid-state solid-state solid-stateReferences RE11LAMW RE11LCBM RE11LMBM(3) Multifunction: On-delay, Off-delay, Totaliser, Symmetrical flashing, Chronometer, Pulse on energisation, Pulse output, Timing after closing/opening of control contact.910Panel-mounted relays Timer on-delay Asymmetrical Multifunction (4) Multifunction (5)flasherPower supply24…240 VAC/DCTime range0,02 s…300 hOutput2 relay 5 AReference RE48ATM12MW RE48ACV12MW RE48AMH13MW (6) RE48AML12MWBack panel mounting socket RUZC2M RUZC3M RUZC2M RUZC3MFront panel mounting socket RE48ASOC8SOLD RE48ASOC11SOLD RE48ASOC8SOLD RE48ASOC11SOLD(4) Timer on-delay / pulse on energization(5) Timer on-delay / calibrator / timer off-delay / symmetrical flasher(6) 1 selectable in instantaneousOther versions: please consult our Customer Care Centre.3/12


Industrial timers1Type of single function relaywidth 22.5 mm, relay outputOn-delay Off-delayExternal control no yes no yes yesSupply voltage 24 VAC/DC 24 VAC/DC 24...240 VAC/DC 24 VAC/DC 24 VAC/DC110…240 VAC 42…48 VAC/DC 42…48 VAC/DC 42…48 VAC/DC110…240 VAC 110…240 VAC 110…240 VACTiming range 0.05 s...300 h 0.05 s...300 h 0.05 s...10 mn 0.05 s...300 h 0.05 s...300 hOutput 1 C/O 2 C/O (1) 1 C/O 2 C/O (1) 1 C/OReferences RE7TL11BU RE7TP13BU RE7RB11MW RE7RL13BU RE7RM11BU(1) 1 selectable in instantaneous mode.234Type of relaySingle functionMultifunctionwidth 22.5 mm, relay outputAsymmetrical flashing Pulse on energisation 6 functions (2) 8 functions (3)External control yes no – –Supply voltage 24 VAC/DC 24 VAC/DC 24 VAC/DC 24 VAC/DC42…48 VAC/DC 110…240 VAC 42…48 VAC/DC 110…240 VAC110…240 VAC 110…240 VACTiming range 0.05 s...300 h 0.05 s...300 h 0.05 s...300 h 0.05 s...300 hOutput 1 C/O 1 C/O 1 C/O 2 C/O (4)References RE7CV11BU RE7PE11BU RE7ML11BU RE7MY13BU(2) RE7ML11BU functions: On-delay, Off-delay, Pulse on energisation with start on energisation, Pulse on energisation with start on opening of remote control contact, Flashing withstart during the OFF period, Flashing with start during the ON period.(3) REMY13BU functions: On-delay, Off-delay, Pulse on energisation with start on energisation, Pulse on energisation with start on opening of remote control contact, Flashing withstart during the OFF period, Flashing with start during the ON period, Star-delta starting with double On-delay timing, Star-delta starting with contact for switching to star connection.(4) 1 selectable in instantaneous modeMiniature plug-in relays, relay output5678FunctionsTiming ranges 7 switchable ranges 0.1 s…1 s - 1 s…10 s - 0.1 min…1 min - 1 min…10 min - 0.1 h…1 h - 1 h…10 h - 10 h…100 hRelay output 4 timed C/O contacts 2 timed C/O contactsRated current 3 AC 5 A AC 5 AVoltages 24 VDC RE XL4TMBD RE XL2TMBD24 VAC 50/60 Hz RE XL4TMB7 RE XL2TMB7120 VAC 50/60 Hz RE XL4TMF7 RE XL2TMF7230 VAC 50/6 0 Hz RE XL4TMP7 RE XL2TMP7Socket with mixed contact terminals With screw clamp RXZE2M114 RXZE2M114With connector RXZE2M114M RXZE2M114M910Other versions: please consult our Customer Care Centre.3/13


Zelio AnalogAnalog InterfaceUniversal Thermocouple1TypeThermocouple23Temperature range 0…150 °C 0…300 °C 0…600 °C 0…600 °C 0…1200 °C32…302 °F 32…572 °F 32…1112 °F 32…1112 °F 32…2192 °FOutput range0…10 V / 0…20 mA - 4…20 mA SwitchableDimensions H x W x D80 x 22,5 x 80 mmVoltage24 VDC - Non isolatedReferences RMTJ40BD RMTJ60BD RMTJ80BD RMTK80BD RMTK90BD45Universal PT 1006Type PT 10078Temperature range -40…40 °C -100…100 °C 0…100 °C 0…250 °C 0…500 °C-40…104 °F -148…212 °F 32…212 °F 32…482 °F 32…932 °FOutput range0…10 V / 0…20 mA - 4…20 mA SwitchableDimensions H x W x D80 x 22,5 x 80 mmVoltage24 VDC - Non isolatedReferences RMPT10BD RMPT20BD RMPT30BD RMPT50BD RMPT70BD9103/14Other versions: please consult our Customer Care Centre.


Optimum PT 1001Type PT 100Temperature range -40…40 °C -100…100 °C 0…100 °C 0…250 °C 0…500 °C-40…104 °F -148…212 °F 32…212 °F 32…482 °F 32…932 °FOutput range0…10 VDimensions H x W x D80 x 22,5 x 80 mmVoltage24 VDC - Non isolatedReferences RMPT13BD RMPT23BD RMPT33BD RMPT53BD RMPT73BD234Universal Analog Converter56TypeAnalog ConverterInput range 0…10 V or 4…20 mA 0…10 V / -10…+10 V 0…50 V / 0…300 V 0…1,5 A / 0…5 A0…20 mA 0…500 V 0…15 A4…20 mAOutput range 0…10 V or 4…20 mA 0…10 V / -10…+10 V 0…10 V 0…10 V or 0…20 mA0…20 mA 0…20 mA ou 4…20 mA4…20 mA Switchable 4…20 mA SwitchableDimensions H x W x D 80 x 22,5 x 80 mm 80 x 45 x 80 mmVoltage 24 VDC - Non isolated 24 VDC - Isolated 24 VDC - Isolated 24 VDC - IsolatedReferences RMCN22BD RMCL55BD RMCV60BD RMCA61BD78910Other versions: please consult our Customer Care Centre.3/15


Zelio LogicSmart relaysCompact, SR21Compact smart relaysWith display, a.c. power supply23Supply voltage 24 VAC 48 VAC 100…240 VACNumber of inputs/outputs 12 20 20 10 12 20 20Number of inputs Discrete inputs 8 12 12 6 8 12 12Number of outputs 4 relay 8 relay 8 relay 4 relay 4 relay 8 relay 8 relayDimensions, W x D x H (mm) 71.2x59.5x107.6 124.6x59.5x107.6 71.2x59.5x107.6 124.6x59.5x107.6Clock yes yes no no yes no yesReferences SR2B121B SR2B201B SR2A201E SR2A101FU (1) SR2B121FU SR2A201FU (1) SR2B201FU(1) Programming on smart relay in LADDER language only45Compact smart relaysWith display, d.c. power supply67Supply voltage 12 VDC 24 VDCNumber of inputs/outputs 12 20 10 12 20 20Number of inputs Discrete inputs 8 12 6 8 12 12including 0-10 V analogue inputs 4 6 - 4 2 6Number of outputs 4 relay 8 relay 4 relay 4 8 relay 8Dimensions, W x D x H (mm) 71.2x59.5x107.6 124.6x59.5x107.6 71.2x59.5x107.6 124.6x59.5x107.6Clock yes yes no yes no yesReferences SR2B121JD SR2B201JD SR2A101BD (1) SR2B12pBD (2) SR2A201BD (1) SR2B20pBD (2)(1) Programming on smart relay in LADDER language only(2) Replace the p by number 1 to order a smart relay with relay output or by 2 for a smart relay with transistor output (Example: SR2B121BD)8910Compact smart relaysWithout display and without buttonsSupply voltage 100…240 VAC 24 VDCNumber of discrete inputs/outputs 10 12 20 10 12 20Number of inputs Discrete inputs 6 8 12 6 8 12including 0-10 V analogue inputs – – – – 4 6Number of outputs 4 relay 4 relay 8 relay 4 relay 4 relay 8 relayDimensions, W x D x H (mm) 71.2x59.5x107.6 124.6x59.5x107.6 71.2x59.5x107.6 124.6x59.5x107.6Clock no yes yes no yes yesReferences SR2D101FU (1) SR2E121FU SR2E201FU SR2D101BD (1) SR2E121BD (3) SR2E201BD (3)(1) Programming on smart relay in LADDER language only(3) To order a smart relay for a 24 VAC supply (no analogue inputs), delete the letter D from the end of the reference (SR2E121B and SR2E201B)3/16Other versions: please consult our Customer Care Centre.


Modular, SR31Modular smart relays*With displaySupply voltage 24 VAC 100…240 VAC 12 VDC 24 VDCNumber of inputs/outputs 10 26 10 26 26 10 26Number of inputs Discrete inputs 6 16 6 16 16 6 16including 0-10 V analogue inputs – – – – 6 4 6Number of outputs 4 relay 10 relay 4 relay 10 relay 10 relay 4 10Dimensions, W x D x H (mm) 71.2x59.5x107.6 124.6x59.5x107.6 71.2x59.5x107.6 124.6x59.5x107.6 124.6x59.5x107.6 71.2x59.5x107.6 124.6x59.5x107.6Clock yes yes yes yes yes yes yesReferences SR3B101B SR3B261B SR3B101FU SR3B261FU SR3B261JD SR3B10pBD (1) SR3B26pBD(1)*The modular base can be fitted with one I/O extension module. The 24 VDC modular base can be fitted with one communication module and/or one I/O extension module(1) Replace the p by number 1 to order a smart relay with relay output (SR3B101BD) or by 2 for a smart relay with transistor output (SR3B102BD)234Extension modules for Zelio Logic SR3Bppppp (2) Communication Discrete Inputs/Outputs AnalogueInputs/OutputsNetwork Modbus Ethernet – –Number of inputs/outputs – – 6 10 14 4Number of inputs Discrete – – 4 6 8 –Analogue (0…10 V, 0…20 mA, PT100) – – – – – 2 (1 PT100 max.)Number of outputs Relay – – 2 relay 4 relay 6 relay –Analogue (0…10 V) – – – – – 2Dimensions, W x D x H (mm) 35.5x59.5x107.6 35.5x59.5x107.6 72x59.5x107.6 35.5x59.5x107.6References 24 VAC – – SR3XT61B SR3XT101B SR3XT141B –100…240 VAC – – SR3XT61FU SR3XT101FU SR3XT141FU –12 VDC – – SR3XT61JD SR3XT101JD SR3XT141JD –24 VDC SR3MBU01BD SR3NET01BD SR3XT61BD SR3XT101BD SR3XT141BD SR3XT43BD(2) The power supply of the extension modules is provided via the Zelio Logic modular relays567Zelio Soft 2 software and programming toolsZelio Soft 2 software, connecting cables,wireless connecting, memoryDescriptionMultilingualConnecting cablesprogramming softwareCD ROM PC (Windows XP, SerialVista 32 bits and Windows 7 PC/Smart32 bits) (3)relayUSBPC/SmartrelayXBT N/RInterfaceHMISTOInterfaceWireless Back-upconnection memoryBluetooth EEPROMinterfaceReferences SR2SFT01 SR2CBL01 SR2USB01 SR2CBL08 SR2CBL09 SR2BTC01 SR2MEM02(3) CD-ROM including Zelio Soft 2 programming software, an application library, a self-training manual, installation instructions and a user’s manualCommunication interface for SR2/SR3Interface, modems, Zelio Logic Alarm software Communication Modems (4)Alarm management softwareinterfaceSupply voltage 12…24 VDC 12…24 VDC 12…24 VDC –Description – Analogue modem GSM modem PC CD-ROM (Windows 98, NT, 2000, XP)Dimensions, W x D x H (mm) 72x59.5x107.6 120.7x35x80.5 111x 25.5x54.5 –References SR2COM01 SR2MOD01 SR2MOD02 SR2SFT02(4) Must be used in conjunction with communication interface SR2COM01Other versions: please consult our Customer Care Centre.3/178910


TwidoProgrammable controllersBases1Type of baseCompact2345Number of digital i/O 10 16 24 40Number of digital inputs (24 VDC) 6 sink/source 9 sink/source 14 sink/source 24 sink/sourceNumber of digital outputs 4 relay (2 A) 7 relay (2 A) 10 relay (2 A) 14 relay (2 A),2 solid-state (1 A)Type of connectionScrew terminals (non removable)Possible I/O expansion modules – – 4 7Counting3 x 5 kHz, 1 x 20 kHzPWM positioning – 2 x 7 kHzSerial ports 1 x RS 485 1 x RS 485; option: 1 x RS 232C or RS 485ProtocolModbus master/slave, ASCII, I/O relocationEthernet port – – – RJ45 EthernetDimensions, W x D x H 80 x 70 x 90 mm 80 x 70 x 90 mm 95 x 70 x 90 mm 157 x 70 x 90 mmReferences Supply voltage 100…240 VAC TWDLCAA10DRF TWDLCAA16DRF TWDLCAA24DRF TWDLCAE40DRF (1)Supply voltage 19.2…30 VDC TWDLCDA10DRF TWDLCDA16DRF TWDLCDA24DRF TWDLCDE40DRF (1)Real-time clock (option)TWDXCPRTCDisplay unit (option)TWDXCPODCMemory cartridge (option) TWDXCPMFK32 (3) TWDXCPMFK64 (4)(1) 40 I/O version without Ethernet also available: TWDLCAA40DRF and TWDLCDA40DRF67Type of baseModular8910Number of digital i/O 20 40Number of digital inputs (24 VDC) 12 sink/source 12 sink/source 24 sink/sourceNumber of digital outputs 8 transistor, source (0.3 A) 6 relay (2 A) & 2 trans., source (0.3 A) 16 transistor, source (0.3 A)Type of connection HE10 connector Removable screw terminals HE10 connectorPossible I/O expansion modules 4 7 7Supply voltage24 VDCCounting2 x 5 kHz, 2 x 20 kHzPLS/PWM positioning2 x 7 kHzSerial ports 1 x RS 485; option: 1 x RS 232C or RS 485ProtocolModbus master/slave, ASCII, I/O relocationDimensions, W x D x H 35.4 x 70 x 90 mm 47.5 x 70 x 90 mm 47.5 x 70 x 90 mmReferences TWDLMDA20DTK (2) TWDLMDA20DRT TWDLMDA40DTK (2)Real-time clock (option)TWDXCPRTCDisplay unit (option)TWDXCPODMMemory cartridge (option) TWDXCPMFK32 (3) TWDXCPMFK64 (4)(2) Sink version transistor outputs also available: TWDLMDA20DUK and TWDLMDA40DUK(3) Application backup, program transfer(4) Memory expansion, application backup, program transfer3/18Other versions: please consult our Customer Care Centre.


Programmable controllersI/O modules1Type of moduleAnalogue inputsNumber of inputs 2 I 2 I 4 I 8 I 8 I 8 I 8 IConnection Removable screw terminals RJ11Inputs Range Thermocouples 0…10 V (1) 0…10 V (1) 0…10 V (1) PTC/NTC Thermo probetype K, J, T 4…20 mA (2) 0…20 mA (2) 0…20 mA (2)Pt100 / Pt1000θ °C- 200...+ 600 °CResolution 12 bits (4096 points) 10 bits (1024 points) 12 bits (4096 points)Supply voltage24 VDCDimensions, W x D x H 23.5 x 70 x 90 mm 39.1x70x90 mmReferences TM2AMI2LT TM2AMI2HT TM2AMI4LT TM2AMI8HT TM2ARI8HT TM2ARI8LT TM2ARI8LRJ(1) Non differential(2) Differential234Type of moduleAnalogue Outputs, Inputs/Outputs (mixed)Number of inputs and/or outputs 1 O 2 O 2 I / 1 O 2 I / 1 O 4 I / 2 OConnectionRemovable screw terminalsInputs Range – – 0…10 V (1) Thermocouple type K, J & T 0…10 V (1)4…20 mA (2) 3-wire Pt 100 thermal probe 4…20 mA (2)Resolution – – 12 bits (4096 points) 12 bits (4096 points) 12 bits (4096 points)Outputs Range 0…10 V (1) ± 10 V 0…10 V (1) 0…10 V (1) 0…10 V (1)4…20 mA (2) 4…20 mA (2) 4…20 mA (2) 4…20 mA (2)Resolution 12 bits 11 bits + sign 12 bits 12 bits 12 bitsSupply voltage24 VDCDimensions, W X D x H23.5 x 70 x 90 mmReferences TM2AMO1HT TM2AVO2HT TM2AMM3HT TM2ALM3LT TM2AMM6HT(1) Non differential(2) Differential5678Type of moduleDigital Inputs/OutputsNumber of inputs and/or outputs 8 16 16 32 4 I / 4 O 16 I / 8 OConnection Removable screw terminals HE10 connectors Removable Spring terminalsscrew terminals (non removable)References Inputs 24 VDC sink TM2DDI8DT – – – – –24 VDC sink/source – TM2DDI16DT TM2DDI16DK TM2DDI32DK120 V sink TM2DAI8DT – – – – –Outputs Relay (2 A) TM2DRA8RT TM2DRA16RT – – –Transistor, source 0.5 A TM2DD08TT – – – – –Transistor, source 0.4 A – – TM2DD016TK TM2DD032TK – –Transistor, sink 0.1 A TM2DDO8UT – TM2DDO16UK TM2DDO32UK – –Inputs, 24 VDC + Outputs, Relais 2 A – – – – TM2DMM8DRT TM2DMM24DRF910Other versions: please consult our Customer Care Centre.3/19


TwidoProgrammable controllersCommunication modules forTwido Compact and Modular bases1Type of module Serial interface Serial interface adaptor23Physical layer (non isolated) RS 232C RS 485 RS 232C RS 485Connection Mini-DIN connector Screw terminals Mini-DIN connector Screw terminalsProtocolModbus master/slave, ASCII, I/O relocationTwido base compatibility Modular base TWDLMDA Compact base TWDLCAA16/24DRFModular base via integrated display module TWDXCPODMReferences TWDNOZ232D TWDNOZ485D TWDNOZ485T TWDNAC232D TWDNAC485D TWDNAC485T456Type of moduleModem forTwidoCANopenexpansionEthernetinterfaceModbusisolationmoduleModbusjunctionmoduleAS-InterfacemasterNumber of modules – 1 1 – – 2 (1)Connection – SUB-D9 RJ45 RJ45 RJ45 Removablescrew terminalsTwido base compatibility – 20, 24 or 40 I/ObaseAll models All models All models 20, 24 or 40 I/ObaseReferences SR2MOD03 TWDNCO1M 499TWD01100 TWDXCAISO TWDXCAT3RJ TWDNOI10M3(1) 2 modules max., 62 digital slaves max., 7 analogue slaves max., AS-Interface/M3, V 2.11 (profile S.7.4 not supported)78Programming software910Software, connecting cables, interfacesTwidoSuitesoftwareEN/FRConnecting cablesApplicationPC with Windows Twido/PCTwido/PCXP or Vista USB portserial portReferences TWDBTFU10M TSXCUSB485 (2)TSXCRJMD25 (2)(2) For Twido Extreme: order the reference VW3A8106Bluetooth®USB adaptorFor PC not fittedwith Bluetooth®Bluetooth®gatewayFor TwidocontrollerTSXPCX1031 (2) VW3A8115 VW3A81143/20Other versions: please consult our Customer Care Centre.


Programmable controllersBases1Fixing and connection Fixing kit 70-pin connector Pre-wired 70-pinconnectorDetails 4 spacers, 80 pins, Pre-wired with 1.5 m long cable,8 washers, 80 blanking plugs, free wires other end8 shock mounts 1 coverDegree of protection – IP67 IP67References TWDXMTK4 TWDFCNK70 TWDFCWK70L015234Separate componentsCrimping toolApplicationReferencesCrimping wires onto pinsof 70-pin connectorTWDXMTCT5678910Other versions: please consult our Customer Care Centre.3/21


Modicon M340Programmable Automation ControllerProcessor modules1Type of processor Standard High-performance234567Number of racks 2 (4, 6, 8 or 12 slots) 4 (4, 6, 8 or 12 slots)Maximum configurationMaximum 24 slots for processor andmodules (excluding power supply module)Maximum 48 slots for processor andmodules (excluding power supply module)Functions Max. no. (1) Discrete I/O 512 1024Analog I/O 128 256Control channelsProgrammable loops (via CONT-CTL process control EFB library)Counter channels 20 36Motion control – Independent axeson CANopen bus(via MFB library)– Independent axeson CANopen bus(via MFB library)IntegratedconnectionsEthernet TCP/IP – 1 RJ45 port, 10/100 Mb/s, with TransparentReady class B10 standard web serverCANopen master busIntegrated port – 1 (SUB-D9) – 1 (SUB-D9)Serial link 1 RJ45 port, Modbus master/slave RTU/ASCII or character mode –(non isolated RS 232C/RS 485), 0.3...19.2 Kb/sUSB port1 port, 12 Mb/sCommunication Ethernet TCP/IP 1 RJ45 port, 10/100 Mb/s with:module- Transparent Ready class B30 standard web server with BMX NOE 0100 module- Transparent Ready class C30 confi guration web server with BMX NOE 0110 moduleInternal user Total capacity 2048 Kb 4096 KbRAM Program, constants and symbols 1792 Kb 3584 KbData 128 Kb 256 KbExecution time for Boolean 0.18 μs 0.12 μsone instruction On words or fi xed point Single-length words 0.38 μs 0.25 μsarithmetic Double-length words 0.26 μs 0.17 μsOn floating points 1.74 μs 1.16 μsNo. of K instructions 100% Boolean 5.4 Kinst/ms 8.1 Kinst/msexecuted per ms 65% Boolean and 35% fi xed arithmetic 4.2 Kinst/ms 6.4 Kinst/msSystem Master task 1.05 ms 0.70 msoverhead Fast task 0.20 ms 0.13 msReferences BMX P341000 BMX P342000 BMX P3420102 BMX P342020 BMX P3420302(1) Only affects in-rack modules. The remote I/O on the CANopen bus are not included in these maximum numbers.8Memory cards910Type of card 8 MB memory card 8 MB memory card+ 8 MB files8 MB memory card+ 128 MB filesUseSupplied as standard with eachprocessor. Used for:As replacement for the memory card supplied asstandard with each processor, used for:Backup of program, constants, symbols and data– File storage, 8 MB File storage, 128 MBActivation of class B10 web serverCompatibility BMX P34 1000/20... BMX P34 20...References BMX RMS 008MP BMX RMS 008MPF BMX RMS 0128MFP3/22Other versions: please consult our Customer Care Centre.


Modicon M340Programmable Automation ControllerCommunication modules1Type of moduleEthernet NetworkCommunicationSpeed 10/100 Mb/s 10/100 Mb/sProtocols Modbus TCP TCP/IP(Uni-TE, Modbus)EtherNet/IP and Modbus/TCPConformity class Transparent Ready class B30 -Communication service I/O Scanning service Yes YesTransparent Ready FDR service Yes (client/server) Yes (client / server)SNMP network management service Yes Yes (agent)Global Data service Yes NoSOAP/XML Web service No Server -Bandwidth management Yes YesQos - YesRSTP - No SOAPReferences BMX NOE 0100 BMX NOE 0110 BMXNOC0401Memory card Use Provides services conforming to Transparent Ready:Class B Class C No32 MB available foruser web pagesReferences BMX RWS B000M BMX RWS FC032MQos: Quality of Service - RSTP: Rapid Spanning Tree Protocol23456Type of modulePROFIBUS DP V1DesignationPROFIBUS Remote Master (Ethernet Modbus TCP/PROFIBUS DP V1) compatible with allprogrammable automation under UNITY and supporting the I/O scanning serviceStandard version 0…65°Hardened version -25…70°, varnishedSpeed9.6 Kb…12 MbInterfaceRS485 isolated (Sub-D 9 pin female connector)PROFIBUS ServicesMaster Class 1 and 2, support for 125 slaves, Sync & Freeze, Extended diagnostics.Delivered with communication DTM allowing any FDT tool to access the PROFIBUS slaves from theEthernet network by way of the PROFIBUS Remote MasterReferences TCSEGPA23F14F TCSEGPA23F14FK789Type of module Serial link (1) AS-Interface (1)Number of interfaces 2 1Speed 115 Kbits/s –Profile – M4 (AS-i V3)References BMX NOM 0200 BMX EIA 0100(1) For BMXNOC0401 (EtherNet/IP), Profibus DP Gateway TSX EGPA23F14F, Modbus Plus Gateway TCS EGDB23F24FA10Other versions: please consult our Customer Care Centre.3/23


Modicon M340Programmable Automation ControllerPower supply modules1Type of modulePower supply modules23Voltage 24 VDC isolated 24…48 VDC isolated 100…240 VACNominal input current 1A at 24 VDC 1.65 A at 24 VDC 0.61 A at 115 VAC 1.04 A at 0.52 A 100...150 VDC0.83 A at 48 VDC 0.31 A at 220 VDCMicro-break duration ≤ 1Integrated protectionVia internal fuse (not accessible)Max. useful power 17W 32 W 20 W 36 WMax. dissipated power8.5 WRemovable connectors supplied as standardBMX XTS CPS10 (cage clamp)(set of 2)to be ordered separatelyBMX XTS CPS20 (spring-type)References BMX CPS 2010 BMX CPS 3020 BMX CPS 2000 BMX CPS 3500 BMX CPS 3504 (1)4Racks5DesignationRacks6Type of modules to be installedBMX CPS power supply, BMX P34 processor, I/O modules and application-specific modules (counter, communication)No. of slots 4 6 8 12References BMX XBP 0400 BMX XBP 0600 BMX XBP 0800 BMX XBP 12007Rack extensions89Designation Rack extension module Kit for rack extensionStandard module to interconnect rackA complete assembly kit for to racks distant from0.8 m or lessReferences BMX XBE 1000 BMX XBE 2005103/24Other versions: please consult our Customer Care Centre.


Modicon M340Programmable Automation ControllerDiscrete I/O modules1Type of moduleDC input modulesNumber of inputs 16 16 32 64 16 16Connection Screw or spring-type 1 connector 2 connectors Screw or spring-type20-way removable 40-way 40-way 20-way removableterminal blockterminal blockNominal input values Voltage 24 V 48 V 24 V 125 VDCCurrent 3.5 mA 2.5 mA 1 mA 3 mALogic Positive (sink) Negative (source)Input limit values At state 1 Voltage ≥11 V ≥34 V ≥11 V ≥15 V ≥14 VCurrent > 2 mA > 2 mA > 2 mA > 1 mA > 2 mA(for U ≥11 V) (for U ≥34 V) (for U ≥11 V) (for U ≥5 V) (for U ≥15 V)At state 0 Voltage < 5 V < 10 V < 5 VCurrent ≥1.5 mA ≥0.5 mA ≥1.5 mA ≥0.5 mAReferences BMX DDI 1602 BMX DDI 1603 BMX DDI 3202K BMX DDI 6402K BMX DAI 1602 BMX DDI 1604 (1)2345Type of moduleAC input modulesNumber of inputs 16 8ConnectionScrew or spring-type 20-way removable terminal blockNominal input values Voltage 24 VAC 48 AC 100…120 VAC 200...240 VACCurrent 3 mA 10.4 mAFrequency50/60 HzInput limit values At state 1 Voltage ≥15 V ≥34 V ≥74 V ≥159 VCurrent ≥2 mA ≥2.5 mA ≥6 mAAt state 0 Voltage ≤5 V ≤10 V ≤20 V ≤40 VCurrent ≤1 mA ≤4 mAReferences BMX DAI 1602 BMX DAI 1603 BMX DAI 1604 BMX DAI 0805 (2)678Type of moduleDC solid state output modulesNumber of inputs 16 16 32 64Connection Screw or spring-type 20-way removable terminal block One 40-way connector Two 40-way connectorsNominal output values Voltage 24 VDCCurrent 0.5 V 0.1 VLogic Positive (source) Negative (sink) Positive (source)Output limit values Voltage (ripple included) 19…30 (possible up to 34 V, limited to 1 hour in every 24 hours)Current per channel 0.625 A 0.125 ACurrent per moduleMaximum dissipated power 4 2.26 3.6 6.85References BMX DDO 1602 BMX DDO 1612 BMX DDO 3202K BMX DDO 6402K910Other versions: please consult our Customer Care Centre.3/25


Modicon M340Programmable Automation ControllerDiscrete I/O modules1Type of moduleTriac output modules23Number of inputs 16ConnectionScrew or spring-type 20-way removable terminal blockOperating voltage Nominal 100…240 VACLimit85…288 VACCurrents Maximum 0.6 per channel, 2.4 per common, 4.8 for all 4 commons.Minimum 25 mA at 100 V a, 25 mA at 240 V a.Maximum inrush current≤ 20/cycleReferenceBMX DAO1605456Type of moduleRelay output modulesNumber of inputs 8 16 8ConnectionScrew or spring-type 20-way removable terminal blockMax. operating voltage DC 10…34 VDC 24…125 VDC (resistive load)AC 10…264 VAC 200…264 VAC (Cosϕ = 1) 100...150 VDCResponse time Activation < 10 msDeactivation < 8 ms < 12 msDissipated power 2.7 W max 3 WReferences BMX DRA 0805 BMX DRA 1605 BMX DRA 0804 (1)78910Type of module 24 VDC mixed I/O modulesInputs Solid state outputs Inputs Solid state outputsNumber of I/O 8 8 16 16ConnectionScrew or spring-type 20-way removable terminal block One 40-way connectorInput limit values At state 1 Voltage ≥11V ≥11VCurrent ≥3 mA (for U ≥11) ≥2 mA (for U ≥11)At state 0 Voltage 5 V 5 VCurrent ≤1.5 mA ≤1.5 mASensor power supply (ripple included)19…30 V (possible up to 30 V, limited to 1 hour in every 24 hours)Output limit values Voltage (ripple included) 19…30 (possible up to 30 V, limited to 1 hour in every 24 hours)Current per channel 0.625 A 0.125 Aper module 5 A 3.2 AMaximum dissipated power 3.7 W 4 WReferences BMX DDM 16022 BMX DDM 3202K3/26Other versions: please consult our Customer Care Centre.


Modicon M340Programmable Automation ControllerDiscrete I/O modules1Type of module Mixed input/relay output modules24 VDC inputs 24 VDC or 24…240 VAC relay outputsNumber of I/O 8 8ConnectionScrew or spring-type 20-way removable terminal blockNominal values Inputs Voltage 24 VDC (positive logic)Current 3.5 mAOutputs DC voltage 24 VDCDC2 (resistive load)AC voltage 220 VAC, Cosϕ = 1AC2 AInput limit values At state 1 Voltage ≥11VCurrent ≥2 mA (for U ≥ 11 V)At state 0 Voltage 5 VCurrent ≤1.5 mASensor power supply (ripple included) 19…30 V (possible up to 30 V, limited to 1 hour in every 24 hours)Maximum dissipated power3.1 WReference BMX DDM 160252345678910Other versions: please consult our Customer Care Centre.3/27


Modicon M340Programmable Automation ControllerAnalog I/O modules1Type of moduleAnalog input module23Input typeIsolated high-levelinputsIsolated high-levelinputsNon isolatedhigh-level inputsIsolated inputs, low-level voltage, resistors,temperature probes, thermocouplesNumber of channels 4 8 8 4 8Nature of inputs± 10 V, ± 5 V, 0…5 V, 0…10 V, 1…5 V0…20 mA, 4…20 mA , ± 20 mA±40 mV, ±80 mV, ±160 mV, ±320 mV,±640 mV, ±1.28 VResolution 0.35 mV/0.92 μA 15 mV + signReference BMX AMI 0410 BMX AMI 0810 (1) BMX AMI 0800 (1) BMX ART 0414 BMX ART 08144Type of moduleAnalog output module567Output type Isolated high-level outputs Non isolated high-level outputsNumber of channels 2 4 8Range Voltage ± 10 V –Current 0…20 mA and 4…20 mA –Resolution15 bits + signReference BMX AMO 0210 BMX AMO 0410 (1) BMX AMO 0802 (1)Type of moduleMixed analog I/O moduleChannel type Non-isolated high-level inputs Non-isolated high-level outputsNumber of channels 4 2Ranges ±10 V, 0…5 V, 0…10 V, 1…5 V, 0…20 mA, 4…20 mA ±10 V, 0…20 mA, 4…20 mAMaximum conversion value Voltage ± 11.25 V ± 11.25 VCurrent 0…30 0…24 mAResolution 14 bits, 12 bits, 13 bits, 12 bits 12 bits, 11 bitsReference BMX AMM 0600Counter and motion control modules8910Type of module Counter module Motion Control32 bits 16 bits 32 bits ModuleModularity 2 channels 8 channels 4 channels 4 channelsNo. of sensor inputs 6 per channel 2 per channel 3 per channel 4 auxiliary inputsNo. of actuator outputs 2 per channel 2 auxiliary outputsModule cycle time 1 ms 5 ms –ApplicationsUpcounting, downcounting,measurement, frequency meter,frequency generator, axis followingUpcounting, downcounting,measurementFrequency generator, Move,set positionReferences BMX EHC 0200 BMX EHC 0800 BMX MSP 02003/28Other versions: please consult our Customer Care Centre.


Modicon M340Programmable Automation ControllerConnection accessories1Removable terminal blocks 20-way 28-wayFor use with modules BMX AMI 0410 - BMX AM0 0210 - BMX AMM 0600 - BMX EHC 0800 BMX MSP 200,BMX AMI 0800 / AMI 0810For use with TOR modulesAll 8 and 16 channel modulesComposition Cage clamp Screw clamp Spring-typeReference BMX FTB 2000 BMX FTB 2010 BMX FTB 2020 BMX FTB 282023Some racks, power supply, communication modules and specific modules, plus all the analogmodules are now available in «ruggedized version». The references of these products end by a H.45678910Other versions: please consult our Customer Care Centre.3/29


Modicon PremiumProgrammable Automation ControllerProcessors under Unity Pro software1234Type of processor TSX 57104 racks max.TSX 572016 racks max.TSX 573016 racks max.Number of I/O Discrete 512 1024 1024in racks Analog 24 80 128Integrated process control No / Yes 30 loops / Yes 45 loops / YesApplication-specific channels (counter, position control, weighing) 8 24 32Bus AS-Interface cabling system 2 4 8CANopen machine bus 1 1 1INTERBUS, Profibus DP fieldbus – 1 3Networks (Ethernet, Modbus Plus, Fipway) 1 2 3Memory capacity Without PCMCIA extension 96 Kb data/prog. 160/192 Kb data/prog. (1) 192/208 Kb data/prog. (1)With PCMCIA extension 96 Kb data/224 Kb prog. 160/192 Kb data (1)/768 Kb prog. 192/208 Kb data (1)/1,75 MB prog.Execution time for one Boolean 0.19 μs 0.19 μs 0.12 μsinstruction without ext. PCMCIA On word or arithmetic 0.25 μs 0.25 μs 0.17 μsReference Without integrated port TSXP57104M (6) TSXP57204M (6) TSXP57304M (6)Integrated Ethernet TSXP571634M (2) (6) TSXP572634M (6) TSXP573634M (6)Integrated CANopen – – –Integrated Fipio TSXP57154M (6) TSXP57254M (6) TSXP57354M (6)5Processors under PL7 software678910Type of processor TSX 57104 racks max.TSX 572016 racks max.TSX 573016 racks max.Number of I/O Discrete 512 1024 1024in racks Analog 24 80 128Integrated process control No 30 loops 45 loopsApplication-specific channels (counter, position control, weighing) 8 24 32Bus AS-Interface cabling system 2 4 8CANopen machine bus 1 (with TSXP57103M) 1 1INTERBUS, Profibus DP fieldbus – 1 2Networks (Ethernet, Modbus Plus, Fipway) 1 1 3Memory capacity Without PCMCIA extension 32 K words data/prog. 48 K words data/prog. (4) 64/80 K words data/prog. (4)With PCMCIA extension 32 K words data/64 K words prog. 32 K words data (4)/160 K words prog. 80/96 K words data (4)/384 K words prog.Execution time for one Boolean 0.19 μs 0.19 μs 0.12 μsinstruction without ext. PCMCIA On word or arithmetic 0.25 μs 0.25 μs 0.17 μsReference Without integrated port TSXP57103M (6) TSXP57203M (6) TSXP57303AM (6)Integrated Ethernet – TSXP572623M (6) TSXP573623AM (6)Integrated Fipio TSXP57153M (6) TSXP57253M (6) TSXP57353AM (6)Integrated Ethernet and Fipio – TSXP572823M (6) –(1) The second value corresponds to the integrated memory capacity when the processor is equipped with a Fipio manager integrated link(2) Processor with double format(3) PC format card on PCI bus(4) The second value corresponds to the processor with integrated Fipio bus manager link.(5) with PL7 V4.4 min.(6) For coated version add C at the end of the reference: example TSXP571634M becomes TSXP571634MC3/30Other versions: please consult our Customer Care Centre.


HotStandBy offer1TSX 574016 racks max.TSX 575016 racks max.TSX 576016 racksTSXH5724M16 racksTSXH5744M16 racks2048 2048 2048 512 512256 512 512 80 12860 loops / Yes 90 loops / Yes 90 loops / Yes 30 loops / Yes 60 loops / Yes64 64 64 16 (serial communication) 16 (serial communication)8 8 8 0 01 1 1 0 04 5 5 0 04 4 4 2 4320 Kb data/prog. 1024 Kb data/prog. 2048 Kb data/prog. 192 Kb 440 Kb440 Kb data/2 MB prog. 1024 Kb data/7 MB prog. 2048 Kb data/7 MB prog. 192 Kb data/768 Kb prog. 440 Ko data/2 MB prog.0.06 μs 0.037 μs 0,037 μs 0,039 μs 0,039 μs0.07 μs 0.045 μs 0,045 μs 0,054 μs 0,054 μs– – – TSXH5724M (6) TSXH5744M (6)TSXP574634M (6) TSXP575634M (6) TSXP576634M (6)– – –TSXP57454M (6) TSXP57554M (6) –2345678910Other versions: please consult our Customer Care Centre.3/31


Modicon PremiumProgrammable Automation ControllerMemory extensions for Unity Pro processors1Type of PCMCIA card Application Additional data2345Technology SRAM Flash EPROM only SRAMMemory size 96 Kb – TSXMFPB096K (3) –128 Kb TSXMRPP128K TSXMFPP128K –224 Kb TSXMRPP224K / TSXMCPC224K TSXMFPP224K –384 Kb TSXMRPP384K TSXMFPP384K –448 Kb TSXMRPC448K (1) – –512 Kb – TSXMCPC512K (2) / TSXMFPP512K –768 Kb TSXMRPC768K (1) – –1 MB TSXMRPC001M (1) (6) TSXMFPP001M –1.7 MB TSXMRPC01M7 – –2 MB TSXMRPC002M (1) TSXMCPC002M (2) / TSXMFPPC002M –3 MB TSXMRPC003M (1) (6) – –4 MB – TSXMFPP004M TSXMRPF004M7 MB TSXMRPC007M (1) (6) – –8 MB – – TSXMRPF008M(1) By configuration, the user can reserve part of the memory space for data storage (recipes, production data) on request.(2) These cards have an additional SRAM area for storing data (recipes, production data).(3) Backup cartridge of the program when this one reside entirely in PLC internal memory.Memory extensions for PL7 processors67Type of PCMCIA card Application Additional data8910Technology SRAM Flash EPROM only SRAMMemory size (4) 32 K words TSXMRPP128K TSXMFPP128K –64 K words TSXMRPP224K TSXMFPP224K –64 K words/128 K words TSXMRPP384K TSXMCPC224K –96 K words – TSXMFPB096K –128 K words TSXMRPC448K TSXMFPP384K –128 K words/128 K words TSXMRPC768K (5) – –256 K words TSXMRPC001M (6) – –256 K words/640 K words TSXMRPC01M7 (5) – –384 K words/640 K words TSXMRPC002M – –512 K words TSXMRPC003M (5) (6) – –992 K words/640 K words TSXMRPC007M (6) – –2048 K words – – TSXMRPF004M(4) The 1 st value corresponds to the size of the application area, the second to the size of the additional data area for storing data (recipes, production data, etc).(5) These cards have an additional SRAM area for storing application object symbols.(6) For coated version add C at the end of the reference: example TSXMRPC001M becomes TSXMRPC001MC3/32Other versions: please consult our Customer Care Centre.


Power supply modules (1)1Type of power supply module for Premium Atrium (2)Input voltage 24 VDC 100…240 VAC 100…120/200…240 VAC 24 VDCOutput voltage 5 VDC/24 VDC 5 VDCTotal useful power 26 W 50 W 26 W 50 W 77 W 26 WFormat Standard Double Standard Double Double –Reference TSXPSY1610M (4) TSXPSY3610M (4) TSXPSY2600M (4) TSXPSY5500M (4) TSXPSY8500M (4) TSXPSI2010(1) Process power supplies see chapter 6 “Power supply”(2) Only for Atrium slot-PLCs under Unity23Racks45Type of rack Non extendable ExtendableFor configuration Mono-rack Multi-rack (16 max.)Dimensions WxDxPReference 4 positions 188 x 160 x 151,5 mm (3) – TSXRKY4EX (4)6 positions 261,6 x 160 x 151,5 mm (3) TSXRKY6 (4) TSXRKY6EX (4)8 positions 335,3 x 160 x 151,5 mm (3) TSXRKY8 (4) TSXRKY8EX (4)12 positions 482,6 x 160 x 151,5 mm (3) TSXRKY12 (4) TSXRKY12EX (4)(3) Hight of I/O modules : 151,5 mm with HE 10 or SUB-D connectors, 165 mm with screw terminals(4) For coated version add C at the end of the reference: example TSXPSY1610M becomes TSXPSY1610MC67Connection accessoriesTypeBus X daisy chaining cable for Line terminators and accessoriesextendable racks– Set of 2Reference – TSXTLYEX– TSXTVSY100 (2 Bus X Transcient voltagesuppressor) (5)L = 1 m TSXCBY010K –L = 3 m TSXCBY030K –L = 5 m TSXCBY050K –L = 12 m TSXCBY120K –L = 18 m TSXCBY180K –L = 28 m TSXCBY280KT –L = 38 m TSXCBY380KT –L = 50 m TSXCBY500KT –L = 72 m TSXCBY720KT –L = 100 m TSXCBY1000KT –(5) Available 1Q 2010.8910Other versions: please consult our Customer Care Centre.3/33


Modicon PremiumProgrammable Automation ControllerDiscrete I/O modules1Type of moduleDiscrete inputs2Connection By screw terminals TSXBLY01 (1) By HE 10 connector (2) high densityNumber of isolated channels 8 16 16 (3) 32 64Input voltage 24 VDC TSXDEY08D2 (5) TSXDEY16D2 (5) TSXDEY16FK (5) TSXDEY32D2K (5) TSXDEY64D2K (5)48 VDC – TSXDEY16D3 (5) – TSXDEY32D3K (5) –24 VAC – TSXDEY16A2 (4) (5) – – –3448 VAC – TSXDEY16A3 (5) – – –100…120 VAC – TSXDEY16A4 (5) – – –200…240 VAC – TSXDEY16A5 (5) – – –(1) Terminal block to be ordered separately(2) For use with Modicon ABE7 wiring system(3) Module with high-speed isolated inputs (filtering from 0.1 to 7.5 ms) able to activate the event-triggered task(4) Module also compatible with 24 VDC negative logic5678Type of moduleDiscrete outputsSolid state Relay TriacConnection By screw terminals TSXBLY01 (1) By HE10 conn. (2) By screw terminals TSXBLY01 (1)Number of protected channels 8 16 32 64 8 16 8 16Output voltage/current 24 VDC/0,5 A TSXDSY08T2 (5) TSXDSY16T2 (5) – – – – – –(1) Terminal block to be ordered separately(2) For use with Modicon ABE7 wiring system24 VDC/2 A TSXDSY08T22 (5) – – – – – – –24 VDC/0.1 A – – TSXDSY32T2K (5) TSXDSY64T2K (5) – – – –48 VDC/1 A TSXDSY08T31 (5) – – – – – – –48 VDC/0.25 A – TSXDSY16T3 (5) – – – – – –24…48 VDC-24…240 VAC/5 A Th.c – – – – TSXDSY08R5A (5) – – –24…120 VAC/5 A Th.c – – – – TSXDSY08R4D (5) – – –24…120 VAC/1 A – – – – – – – TSXDSY16S4 (5)48…240 VAC/1 A – – – – – – – TSXDSY16S548…240 VA /2 A – – – – – – TSXDSY08S5 –24 VDC-24…240 VAC/3A – – – – TSXDSY08R5 (5) TSXDSY16R5 (5) – –9Type of moduleDiscrete I/O10ConnectionBy HE 10 connector (2) high densityNumber of inputs16 high-speedNumber of protected outputs 12 solid state 12 reflex or timedOutput voltage/current 24 VDC/0.5 A TSXDMY28FK (5) TSXDMY28RFK (5)(2) For use with Modicon ABE7 wiring system(5) For coated version add C at the end of the reference: example TSXDEY08D2 becomes TSXDEY08D2CConnection accessories: See www.schneider-electric.com3/34Other versions: please consult our Customer Care Centre.


Analog I/O modules1Type of moduleAnalog inputHigh level with common point High level isolated Low level isolatedConnection By 25-way SUB-D connector By terminal block (1)Number of channels 4 high-speed 8 16 8 16 4Resolution 16 bits 12 bits 16 bits 16 bits 16 bitsIsolation Between channels Common point Common point Common point ± 200 VDC ± 100 VDC ± 2830 VrmsBetween channels and earth ~ 1000 Vrms ~ 1000 Vrms ~ 1000 Vrms ~ 1000 Vrms ~ 1000 Vrms ~ 1780 VrmsReference High level input (2) TSXAEY420 (7) TSXAEY800 (7) TSYAEY1600 (7) TSXAEY810 (7) – –Multi-range – – – – TSXAEY1614 (3)(7) TSXAEY414 (4) (7)(1) Screw terminals TSXBLY01 to be ordered separately(2) ± 10 V, 0…10 V, 0…5 V, 1…5 V, 0…20 mA, 4…20 mA(3) ± 63 mV thermocouple (B, E, J, K, L, N, R, S, T, U)(4) ± 10 V, ± 5 V, 0…10 V, 0…5 V, 1…5 V, 0…20 mA, 4…20 mA, -13…+63 mV, 0…400 W, 0…3850 W, thermal probe, thermocouple2345Type of moduleAnalog outputIsolatedWith common pointConnection By screw terminals TSXBLY01 (5) By 25-way SUB-D connectorNumber of channels 4 8Resolution 11 bits + sign 13 bits + signIsolation Between channels ~ 1500 Vrms Common pointBetween channels and earth ~ 1500 Vrms ~ 1000 VrmsReference Input signal (6) TSXASY410 (7) TSXASY800 (7)(5) Terminal block to be ordered separately(6) ± 10 V, 0…10 V, 0…20 mA, 4…20 mA.(7) For coated version add C at the end of the reference: example TSXAEY420 becomes TSXAEY420C678910Connection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.3/35


Modicon PremiumProgrammable Automation ControllerCounter modules1Type of module Counter Counter/measurement Electronic cam234Type of inputs for Sensors (2) Sensors (2) Incremental encoders (3)Incremental encoders (3) Encoders (3)(4) Absolute encoders (5)Counting 40 kHz 500 kHz/200 kHz (5)Cycle time module 5 ms 10 ms 1 ms –Number of channels 2 4 2 128 camsNumber of axes – – – 1Reference TSXCTY2A (1) TSXCTY4A (1) TSXCTY2C (1) TSXCCY1128 (1)(1) For coated version add C at the end of the reference: example TSXCTY2A becomes TSXCTY2AC(2) For 2/3-wire PNP/NPN 24 VDC sensors(3) For 5 VDC RS422, 10…30 VDC Totem Pole incremental encoders(4) For SSI serial or parallel output absolute encoders(5) For RS485 serial or parallel output absolute encodersMotion control modules56Module type For translators For analog control servomotors(amplifier for stepper motor) (for asynchronous and brushless motors)Control outputs RS 422 +/- 10 VCompatible with drives Lexium 05, Twin Line Lexium 05 / 15 LP, MP and HP, Twin Line, Lexium 32Functions Linear axes – Limited Limited or infinite Limited or infinite(6)Slave axes – With static ratio With dynamic ratio –Frequency for each axis 187 kHz 500 kHz with incremental encoder, 200 kHz with absolute encoder (7)Number of axes 1 2 2 4 2 4 3Reference TSXCFY11 (1) TSXCFY21 (1) TSXCAY21 (1)TSXCAY41 (1)TSXCAY22 (1) TSXCAY42 (1) TSXCAY33 (1)(6) With linear interpolation on 2 or 3 axes(7) SSI serial or with parallel outputs789Module typeServomotors with SERCOS® digital ring(for brushless motors)Control outputsSERCOS® network ringCompatible with rangesLexium 15 LP, MP, HP and Lexium 32 modular driveFunctionsLinear or infinite independent axes, slave axes with cam profile or ratioProcessing4 sets of axes with linearinterpolation from 2 to 8 axes4 sets of axes with linear and circularinterpolation from 2 to 3 axes (8)4 sets of axes with linearinterpolation from 2 to 8 axesFrequency for each axis4 MB SERCOS® network ringNumber of axes 8 (9) 8 (9) 16 (10)Reference TSXCSY84 TSXCSY85 TSXCSY164(8) TSXCSY85 module supplied with TJE trajectory editor: linear trajectories with links between segments according to polynomial or circular interpolation and circular trajectories.(9) 8 real axes, 4 imaginary axes and 4 remote axes(10) 16 axes (real axes, imaginary and remote axes)Weighing modules10Type of moduleISP Plussupplied uncalibrated supplied calibrated and offerLoad cell inputs / outputs50 measurements (for 1 to 8 load cells) / 2 discrete and 1 RS 485 for display unitReference Without display unit TSXISPY101 (1) Please consult your Schneider-electric agencyWith display unit TSXXBTN410 TSXISPY121 Please consult your Schneider-electric agencyConnection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.3/36


Communication modules1Type of moduleEthernet network communicationSpeed 10 Mb/s 10/100 Mb/sStandard servicesEthway, Modbus TCP Modbus TCP(Uni-TE, Modbus) (Uni-TE, Modbus)EtherNet/IP &Modbus TCP2Transparent Ready Class C10 B30 B30 C30 D10 B30Global Data – Yes Yes Yes – –I/O Scanning – Yes Yes Yes – YesQoS (3)YesTCP Open Yes – – Yes – –Web server Standard services Yes Yes Yes Yes Yes YesFactoryCast services Yes – – Yes – –FactoryCast HMI services – – – – Yes –Reference TSXETY110WS (4) TSXP57 (1) TSXETY4103 (4) TSXETY5103 (4) TSXWMY100 (4) TSXETC101 (2)(1) References: see pages 3/30 and 3/31, Premium processors with integrated Ethernet TCP/IP port(2) Seamless integration of Modbus and EtherNet/IP environments. Full integration in Unity (FDT/DTM technology). Available Unity V5(3) QoS: Quality of Service34Profibus DPV1 is available for Modicon Premium Please refer to page 3/235Type of moduleAS-Interfacecabling systemCANopenmachine busFipio managerfieldbusINTERBUSfieldbusProfibus DP V0fieldbusName and description In-rack PCMCIA Integrated port In-rack In-rackSpeed 167 Kb/s 20 K…1 Mb/s 1 Mb/s 0.5 Mb/s 9.6 K…12 Mb/sReference TS<strong>XS</strong>AY1000 (4) TSXCPP110 (4) TSXP57 (2) TSXIBY100 (4) TSXPBY100(2) References: see pages 3/30 and 3/31, Premium processors with integrated Fipio port67Type of moduleSerial linksUni-Telway Modbus ASCIIName and description Integrated port In-rack PCMCIA In-rack PCMCIA PCMCIASpeed 19.2 Kb/s 19.2 Kb/s 1.2...19.2 Kb/s 19.2 Kb/s 1.2...19.2 Kb/s 1.2...19.2 Kb/sReference With interface RS 485 TSXP57 (1) TS<strong>XS</strong>CY21601 (3) (4) TS<strong>XS</strong>CP114 (4) TS<strong>XS</strong>CY11601 (4) TS<strong>XS</strong>CP114 (4) TS<strong>XS</strong>CP114 (4)(3) Also designed for Modbus serial (channel 0).RS 232D – – TS<strong>XS</strong>CP111 (4) – TS<strong>XS</strong>CP111 (4) TS<strong>XS</strong>CP111 (4)20mA CL – – TS<strong>XS</strong>CP112 (4) – TS<strong>XS</strong>CP112 (4) TS<strong>XS</strong>CP112 (4)89Type of moduleOther networksModbus Plus Fipway Fipio (agent function)Name and description PCMCIA card PCMCIA card PCMCIA cardSpeed 1 Mb/s 1 Mb/s 1 Mb/sReference TSXMBP100 (4) TSXFPP20 (4) TSXFPP10 (4)(4) For coated version add C at the end of the reference: example TSXETY110WS becomes TSXETY110WSCConnection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.3/3710


Modicon QuantumProgrammable Automation ControllerProcessors under Unity Pro software12Type of processor Simple applications Simple and mediumcomplexity applicationsMax. number ofLocalUnlimited (27 slots max.)discrete I/O (1)Remote/distributed31744 inputs (RIO)/8000 inputs (DIO) and 31744 outputs (RIO)/8000 outputs (DIO)3Max. number ofanalog I/O (1)LocalRemote/distributedUnlimited (27 slots max.)1984 inputs (RIO)/500 inputs (DIO) and 1984 outputs (RIO)/500 outputs (DIO)Type of application-specific I/OCounter, motion control, high-speed interrupt inputs, time-stamp, serial link, AS-Interface sensor/actuator bus456Communication ports (2) Integrated Modbus 2 RS 232/RS 485 2 RS 232Modbus Plus 1 integrated, 2 in local rack 1 integrated, 6 in local rackEthernet TCP/IP 2 in local rack 6 in local rackFieldbus Profibus DP: 2 in local rack Profibus DP: 6 in local rackMemory capacity Internal RAM 548 KB 1056 KBWith PCMCIA extension – –Data storage – –Reference 140CPU31110 (4) 140CPU43412U (4)(1) The maximum values for the number of discrete or analog I/O are not cumulative(2) The numbers of communication modules are not cumulative, 2 or 6 in local rack, depending on model(3) Processor compatible with Unity Pro software after updating its firmware (via OS-Loader included in Unity Pro)(4) For coated version add C at the end of the reference: example T140CPU31110 becomes 140CPU31110C(5) Suitable for safety related application up to SIL2 and SIL3789103/38Other versions: please consult our Customer Care Centre.


1Complex applicationsHot Standbyredundant applicationsLong distanceHSBY CPUUnlimited (26 slots max.)Unlimited (13 slotsmax.)Unlimited (26 slotsmax.)Unlimited (13 slotsmax.)Unlimited (26 slotsmax.)31744 inputs (RIO)/8000 inputs (DIO) and 31744 outputs (RIO)/8000 31744 inputs and 31744 inputs (RIO)/8000 31744 inputs and 31744 inputs (RIO)/8000outputs (DIO)31744 outputsinputs (DIO) and 31744 outputs(RIO)/8000 outputs (DIO)31744 outputsinputs (DIO) and 31744 outputs(RIO)/8000 outputs (DIO)Unlimited (27 slots max.)Unlimited (13 slotsmax.)Unlimited (27 slotsmax.)Unlimited (13 slotsmax.)Unlimited (27 slotsmax.)1984 inputs (RIO)/500 inputs (DIO) and 1984 outputs (RIO)/500 outputs 1984 inputs and 1984 1984 inputs (RIO)/500 inputs 1984 inputs and 1984 1984 inputs (RIO)/500 inputs(DIO)outputs(DIO) and 1984 outputs outputs(RIO)/500 outputs (DIO)(DIO) and 1984 outputs(RIO)/500 outputs (DIO)Intrinsically safe I/O, counter, motion control, high-speed interrupt inputs, – – –time-stamp, serial link, AS-Interface sensor/actuator bus1 RS 232/485 1 RS 232/485 1 RS 232/485 1 RS 232/485 1 RS 232/4851 integrated, 6 in local rack 1 integrated 1 integrated, 6 in local rack 1 integrated 1 integrated, 6 in local rack1 integrated, 6 in local rack 1 integrated, 6 in local rack 6 in local rack 1 integrated, 6 in local rack 6 in local rackProfibus DP: 6 in local rack – Profibus DP: 6 in local rack – Profibus DP: 6 in local rack768 KB 1024 KB 3072 KB 1024 KB 1024 KB 1024 MB 3072 KB7 MB 7 MB 7 MB 7 MB 7 MB 7 MB 7 MB8 MB 8 MB 8 MB – 8 MB – 8 MB140CPU65150 (4) 140CPU65160 (4) 140CPU65260 (4) 140CPU65160S (5) 140CPU67160 (4) 140CPU67160S (5) 140CPU672612345678910Other versions: please consult our Customer Care Centre.3/39


Modicon QuantumProgrammable Automation ControllerPower supply modules (1)123Type of power supply module forQuantumInput voltage 24 VDC 48…60 VDC 100…150 VDC 120…130 VAC 115/230 VACOutput current 8 A/3 A (5) 8 A 8 A/3 A 8 A/3 A 11 AReference Type Standalone (2) 140CPS21100 (6) – 140CPS51100 (6) 140CPS11100 (6) –Summable 140CPS21400 (6) 140CPS41400 (6) – – 140CPS11420 (6)Redundant 140CPS22400 (6) 140CPS42400 (6) 140CPS52400 (6) – 140CPS12420 (6)(1) Process power supplies see chapter 6 “Power supply”(2) The output current for the standalone power supply modules is 3 A4PCMCIA memory extensions5678Type of PCMCIA cardApplicationAdditional datafor Unity processors 140CPU65/67Technology SRAM Flash EPROM SRAMMemory size 512 Kb/512 Kb (4) – TSXMCPC512K (3) –1 MB (5) TSXMRPC001M (6) TSXMFPP001M –2 MB (5) TSXMRPC002M TSXMFPP002M –2 MB/1 MB (4) – TSXMCPC002M –3 MB (5) TSXMRPC003M (6) – –4 MB – TSXMFPP004M TSXMRPF004M7 MB (5) TSXMRPC007M (6) – –8 MB – – TSXMRPF008M(3) These cards have an additional SRAM area for storing data (recipes, production data).(4) The 1 st value corresponds to the size of the application area, the second to the size of the additional data area for storing data (recipes, production data, etc)(5) By configuration the user can reserve part of the memory space for data storage (recipes, production data, etc)(6) For coated version add C at the end of the reference: example TSXMRPC001M becomes TSXMRPC001MC9103/40Other versions: please consult our Customer Care Centre.


Racks1TypeRacksDimensions WxDxHReferences 2 slots 104x104x290 mm 140XBP00200 (2)3 slots 143x104x290 mm 140XBP00300 (2)4 slots 184x104x290 mm 140XBP00400 (2)6 slots 265x104x290 mm 140XBP00600 (2)10 slots 428x104x290 mm 140XBP01000 (2)16 slots 671x104x290 mm 140XBP01600 (2)Rack extension module 140XBE10000 (1) (2)(1) Local extension module, to be placed in main rack and secondary rack.(2) For coated version add C at the end of the reference: example 140XBP00200 becomes 140XBP00200C234TypeConnection accessories (3)Cable for extension racks (main and secondary)5References L = 1 m 140XCA71703L = 2 m140XCA71706L = 3 m140XCA71709(3) Other accessories: See www.schneider-electric.com678910Other versions: please consult our Customer Care Centre.3/41


Modicon QuantumProgrammable Automation ControllerDiscrete I/O modules1Type of module (5)Discrete inputs234ConnectionBy screw terminals 140XTS00200 (to be ordered separately)Number of isolated channels 16 4 groups of 8 3 groups of 8 2 groups of 8 6 groups of 16 8 groups of 2Input voltage 5 VDC TTL (negative logic) – 140DDI15310 – – – –24 VDC – 140DDI35300(1)(2) – – 140DDI36400 –10…60 VDC – 140DDI85300 – – – 140DDI8410020…30 VDC – 140DSI35300(1) – – – –125 VDC – – 140DDI67300 – – –24 VAC 140DAI34000 140DAI35300 – – – –48 VAC 140DAI44000 140DAI45300 – – – –115 VAC 140DAI54000 140DAI55300 – 140DAI54300 – –230 VAC 140DAI74000 140DAI75300 – – – –(1) For negative logic, replace 00 at the end of the reference with 10, for example 140DDI35300 becomes 140DDI35310.(2) Non-interfering module in safety related application5678Type of module (5)Discrete outputsSolid stateConnectionBy screw terminals 140XTS00200 (to be ordered separately)Number of protected channels 16 4 groups of 8 4 groups of 4 2 groups of 8 6 groups of 16 2 groups of 6Output voltage/current 5 VDC TTL/0.075 A (3) – 140DDO15310 – – – –24 VDC/0.5 A – 140DDO35301(1)140DDO35300(2)– – – –10…30 VDC/0.5 A (4) – 140DVO85300 – – – –19.2…30 VDC/0.5 A – – – – 140DDO36400 –10…60 VDC/2 A – – – 140DDO84300 – –24...125 VDC/0.75 A – – – – – 140DDO8850024…48 VAC/4 A – – 140DAO84220 – – –24…115 VAC/4 A 140DAO84010 – – – – –24…230 VAC/ 4-3 A 140DAO84000 140DAO85300 – – – –100...230 VAC/4-3 A – – 140DAO84210 – – –(1) For negative logic, replace 01 at the end of the reference with 10, for example 140DDO35301 becomes 140DDO35310.(2) Non-interfering module in safety related application(3) Negative logic(4) Controlled outputs910Type of module (5) Discrete I/O Discrete outputsSolid stateRelayConnection By screw terminals 140XTS00200 (to be ordered separately) –Number of I/O 2 groups of 8/2 groups of 4 1 group of 4/4 isolated–/16 NO –/8 NO/NCInput voltage 24 VDC 115 VAC 125 VDC – –Output voltage/current 24 VDC / 4 A 115 VAC / 8 A 24...125 VDC / 16 A 2 A 5 AReference 140DDM39000 140DAM59000 140DDM69000 140DRA84000 140DRC83000(5) For coated version add C at the end of the reference: example 140DDI15310 becomes 140DDI15310 CConnection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.3/42


Analog I/O modules1Type of module (4)Analog inputsConnectionBy screw terminals 140XTS00200 (to be ordered separately)Number of channels 8 16 8Input signal 4…20 mA 0…25/20 mA (1) Thermal probe Thermocouple1…5 V 4…20 mA Pt, Ni (2)Resolution 12 bits 0…25000 points 16 bits 12 bits + sign 16 bitsReference 140ACI03000 140ACI04000 (3) 140AVI03000 140ARI03010 140ATI03000(1) 0…25 mA, ± 20 mA, 4…20 mA, 0…10 V, ± 10 V, 0…5 V, ± 5 V, 1…5 V.(2) Type B, E, J, K, R, S, T, mV(3) Non-interfering module in safety related application234Type of module (4)Analog output5ConnectionBy screw terminals 140XTS00200 (to be ordered separately)Number of channels 4 8 4Input signal 4…20 mA 0…25/20 mA 0…10 V, ± 10 V4…20 mA 0…5 V, ± 5 VResolution 12 bits 0…25000 points 12 bitsReference 140ACO02000 (3) 140ACO13000 140AVO02000(3) Non-interfering module in safety related application678Type of module (4)Analog I/O9ConnectionBy screw terminals 140XTS00200 (to be ordered separately)Number of inputs 4Number of outputs 2Input signal 0…20 mA, ± 20 mA, 4…20 mA, 0…10 V, ± 10 V, 0…5 V, ± 5 V, 1…5 V.ResolutionInputs 16 bits, outputs 12 bitsReference140AMM09000(4) For coated version add C at the end of the reference: example 140ACI03000 becomes 140ACI03000CConnection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.3/4310


Modicon QuantumProgrammable Automation ControllerCounter and special purpose modules123Type of module High-speed counter High-speed inputs withinterruptTime-stampsystemType of inputs for Incremental encoders Discrete 24 VDC (2) Discrete24…125 VDCCounting frequency 100 kHz 500 kHz – –Number of channels 5 2 16 32Reference 140EHC10500 140EHC20200 140HLI34000 140ERT85410 (4)(2) 3 operating modes: Interrupt, latch, high-speed inputs, on rising or falling edge.4Safety I/O modules567Type of modules Analog DiscreteConnectionScrew terminalNumber of inputs 8 analog inputs 16 discrete inputs –Number of outputs – – 16 discrete outputsInput signal 4…20mA 24VDC –Output voltage – – 24VDCResolution 16 bits – –CertificationSuitable for safety related application up to SIL2 and SIL3, UL, CE, CSA, Haz-locReference 140SAI94000S 140SDI95300S 140SDO95300S8910Connection accessories: See www.schneider-electric.com3/44Other versions: please consult our Customer Care Centre.


Communication modules1Type of moduleEthernet TCP/IP networkSpeed10/100 Mb/sProtocol Modbus TCP Modbus TCP Modbus TCP Modbus TCP EtherNet/IP &Modbus TCPTransparent Ready Class B30 B30 C30 D10 B30Global Data Yes Yes Yes – –I/O Scanning Yes Yes Yes – YesFDR server Yes Yes Yes – YesSNMP protocol Yes Yes Yes Yes YesQoS (1) – – – – YesWeb server Standard services Yes Yes Yes Yes –FactoryCast services – – Yes Yes –FactoryCast HMI services – – – Yes –Reference 140CPU651* (2) 140NOE77101 140NOE77111 140NWM10000 140NOC77101(1) QoS: Quality of Service(2) 140 CPU 651 50, 140 CPU 651 60, 140 CPU 652 60, 140 CPU 671 60234PROFIBUS DPV1 is available for Modicon Quantum Please refer to page 3/235Type of moduleModbus Plus AS-Interface Fieldbusnetworkcabling system INTERBUS Profibus DP Master V1 (1) Modnet fielbusName and description Integrated link In-rack In-rack In-rack In-rackSpeed 1 Mb/s 167 Kb/s 0,5 Mb/s to 12 Mb/s 375 Kb/sReference 140CPU* 140EIA92100 140NOA62200 PTQPDPMV1 140NOG11100(1) from your partner Prosoft, www.prosoft-technology.com* 140 CPU 311 10, 140 CPU 434 12U, 140 CPU 651 50, 140 CPU 651 60, 140 CPU 652 60, 140 CPU 671 60678Type of moduleSerial linkModbusASCIIName and description Integrated link In-rackSpeed 19.2 Kb/s 19.2 Kb/sReference 140CPU* (1) 140ESI06210(1) RS 232/RS 485 on 140CPU651pp and 140CPU67160 processors and RS 232 on 140CPU31110, 140CPU43412A, 140CPU53414A processors.* 140 CPU 311 10, 140 CPU 434 12U, 140 CPU 651 50, 140 CPU 651 60, 140 CPU 652 60, 140 CPU 671 60To operate in a corrosive environment, Quantum modules can be ordered with a conformal coating applied to components of the product.Conformal coating will extend its life and enhance its environmental performance capabilities.To order conformal coating append a C to the standard catalog number. For example, 140CPS 11420 > 140CPS 114 20C910Connection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.3/45


Automation systemsUnity Pro, a SoCollaborative softwareFor Modicon M340, Premium, and Quantum1Software type Unity Pro Small version 4.12License type version 4.1 Single (1 workstation) Group (3 workstations) Team (10 workstations) Site (> 10 workstations)References Software pack UNYSPUSFUCD41 UNYSPUSFGCD41 UNYSPUSFTCD41 –Update (1) UNYSPUSZUCD41 UNYSPUSZGCD41 UNYSPUSZTCD41 –Software type Unity Pro Medium version 4.13License type version 4.1 Single (1 workstation) Group (3 workstations) Team (10 workstations) Site (> 10 workstations)References Software pack UNYSPUMFUCD41 UNYSPUMFGCD41 UNYSPUMFTCD41 –Update (2) UNYSPUMZUCD41 UNYSPUMZGCD41 UNYSPUMZTCD41 –Software type Unity Pro Large version 4.14License type version 4.1 Single (1 workstation) Group (3 workstations) Team (10 workstations) Site (> 10 workstations)References Software pack UNYSPULFUCD41 UNYSPULFGCD41 UNYSPULFTCD41 UNYSPULFFCD41Update (3) UNYSPULZUCD41 UNYSPULZGCD41 UNYSPULZTCD41 UNYSPULZFCD41Software type Unity Pro Extra Large version 4.15License type version 4.1 Single (1 workstation) Group (3 workstations) Team (10 workstations) Site (> 10 workstations)References Software pack UNYSPUEFUCD41 UNYSPUEFGCD41 UNYSPUEFTCD41 UNYSPUEFFCD41Update (4) UNYSPUEZUCD41 UNYSPUEZGCD41 UNYSPUEZTCD41 UNYSPUEZFCD41(1) From Concept S, PL7 Micro, ProWORX NxT Lite and ProWORX 32 Lite(2) From Concept S/M, PL7 M/J, ProWORX NxT Lite and ProWORX 32 Lite(3) From Concept S /M, PL7 M/J/P, ProWORX NxT Lite and ProWORX 32 Lite(4) From all models Concept, PL7, ProWORX NxT and ProWORX 32678910Unity Pro, a SoCollaborative software, is common programming software for debugging and operationof Modicon M340, Premium, and Quantum programmable controller ranges. Unity Pro takes therecognized usage values of PL7 and Concept software and offers a complete set of new functions forimproved productivity and opening to other software.Five IEC61131-3 languages are supported as standard in Unity Pro with all debugging functions, eitheron the simulator or directly online with the programmable controller.Thanks to symbolic variables independent of memory, structured data and user function blocks,application objects are a direct reflection of the automated process application components.Unity Pro operator screens are user-configured in the application from graphic libraries. Operatoraccesses are simple and direct.Unity V 5.0 (Unity V5.0 available 2Q 2010) integrates the PLCopen standard MFB (Motion FunctionBlock) library, simplifyinginstallation of motion controllers on CANopen machine buses: Altivar 31, Altivar 71, Lexium 05,Lexium 15 LP, MP and HP, IclA.Debugging and maintenance are simplified by animated graphic objects.For diagnostics, a window clearly and chronologically displays all system and application faults withtimestamping at source.The fault cause search navigation function enables precise location of the source of missing conditions.XML format, the Web standard for data exchange, has been adopted as Unity application sourceformat. By simple import/export, all or part of the application can be exchanged with other projectsoftware.Finally, the converters integrated in Unity Pro automatically convert PL7 and Concept IEC 61131-3standards and applications.3/46Other versions: please consult our Customer Care Centre.


Unity softwareSpecialized softwareIntegrator system dedicated softwareSoftware type Unity Pro XL Alliance V3.0Licence type version 3.0 Single (1 workstation) Team (10 workstations)References Software pack UNYSPUEFUAL30 UNYSPUEFTAL30Old generation upgrade (1) UNYSPUEZUAL30 UNYSPUSZTCD30Unity update UNYSPUQZUAL30 UNYSPUQZTAL30Software type PLC Suite Alliance V3.0Licence type version 3.0 Single (1 workstation) Team (10 workstations)References Pack (1) UNYSPUQFUAL30 UNYSPUQFTAL30(1) Including Unity Pro XL Alliance, Concept, PL7, ProWORXUnity Pro application comparison softwareSoftware typeUnity DifLicence type version 2.2Single (1 workstation), French and English languages (software and documentation)Reference Software extension (1) UNYSDUDFUCD20Licence type version 2.2Site licence (100 workstations), French and English languages (software and documentation)Reference Software extension (1) UNYSDUZFFCD22(1) Requires version Unity V2.1 or laterSoftware typeUnity LoaderLicence type version 2.1Single (1 workstation)Reference Software pack (1) UNYSMUZUCD21(1) This software is also included in all Unity Pro software packs, Service Pack SP1 available for downloadPLC application and Modicon M340 embedded software updateSFC View application diagnostic and monitoring softwareSoftware typeUnity SFC ViewLicence type version 2.0Single (1 workstation)References Software pack UNYSDUMFUCD20Software typeEF/EFB function development software in C languageUnity EFB ToolkitLicence type version 3.1Single (1 workstation), English language (software and documentation)References Software pack UNYSPUZFUCD31ERenewalUNYCSPSPUZBUSoftware typeCollaboration Unity Pro with W@de RTU modulesRTU Configuration Software for Unity Pro and W@de modulesLicense type version 1.0Single (1 workstation), English language (software and documentation)References Software pack UNYSRTZFUCD10Process application design and generation softwareSoftware typeUnity UAG (Unity Application Generator)Licence type version 3.2 Single (1 workstation) Site (> 10 workstations)References Software pack UAGSEWLFUCD32 UAGSEWLFFCD23Specific Unity Pro solution design software packSoftware typeUnity UDE (Unity Developer’s Edition)Licence typeSingle (1 workstation), English language (software and documentation)Reference Software pack UNYUDEVFUCD21ELicence type version 2.1Single upgrade from version 2.0 to version 2.1 (1 workstation), English language (software and documentation)References Software pack UNYUDEVRUCD21E12345678Specific libraries according to the software usedLibrary typeDesignationControl LibrariesPredictive ControlLibrary (for UnityPro and Concept)Fuzzy ControlLibrary (for UnityPro)TeSys Library (forUnity Pro)HVAC Library (forUnity Pro)Flow CalculationLibrary (for UnityPro)9Licence typeSingle Licence (1 work station)Reference UNYLPCZAUCD10 UNYLFZZAUWB12 UNYLTSZAUWB10 UNYLHVZAUWB10 UNYLAGZAUWB20Library typeSystem LibrariesDesignation Device and Process Library (for UAG) Process Application Library (for UAG)Licence typeSingle Licence (1 workstation)Reference UAGSBTDFUWB13 UAGSBTXFUWB2010*Includes Process Application Library (PAL) V2.0 and Device and Process Library (DPL) V1.0Other versions: please consult our Customer Care Centre.3/47


AutomationProgramming softwareFor Modicon Premium slot-PLCs1Type of softwarePL7 is the common programming, debugging and operating software for the TSX Micro and Premiumranges of PLCs as well as Atrium coprocessors (see pages 3/12, 3/18 and 3/26).PL7 offers 4 IEC languages: Instruction List (IL), Ladder Diagram (LD), Structured Text (ST) andSequential Function Chart (SFC). You can use the most suitable language for each function in yourapplication, making use of the multi-tasking structure of the processors.For using application-specific functions, PL7 directly integrates the application-specific screensrequired for configuration and adjustment as well as supervisory and diagnostics activities.PL7 Micro for TSX Micro platform234Type of license version 4.5 Single (1 station) Single with SyCon V2.8 Group (3 stations) Open Team (10 stations)Reference Software package TLXCDPL7MP45 TLXCDPL7MPC45 TLXCD3PL7MP45 TLXOTPL7MP45MUpdate (1) TLXRCDPL7MP45M TLXRCDPL7MPC45M TLXRCD3PL7MP45M –PL7 Junior for TSX Micro/Premium and Atrium coprocessor platformsType of license version 4.5 Single (1 station) Group (3 stations)Reference Software package TLXCDPL7JP45 TLXCD3PL7JP45Update (1) TLXRCDPL7JP45M TLXRC3DPL7JP45MUpgrade (2) TLXUCDPL7JP45M TLXUCD3PL7JP45MPL7 Pro for TSX Micro/Premium and Atrium coprocessor platformsType of license version 4.5 Single (1 station) Group (3 stations) Open Team (10 stations) Open SiteReference Software package TLXCDPL7PP45 TLXCD3PL7PP45 TLXOTPL7PP45M TLXOSPL7PP45MUpdate (1) TLXRCDPL7PP45M TLXRCD3PL7PP45M – –Upgrade (2) TLXUCDPL7PP45M TLXUCD3PL7PP45M – –(1) From the previous software version.(2) From lower level, earlier version software.5Specialist toolsEF function development software in C language6Type of softwarePL7 SDKC software extensionReferencePL7 SDKC for EF function development software in C languageFor PL7 Micro/Junior/ProTLXLSDKCPL741M78Type of softwarePL7 FUZ software extensionReferenceDevelopment of applications in C languagePL7 FUZ for processing process applications using fuzzy logicFor PL7 Micro/Junior/Pro, TSX Micro/PremiumTLXLPL7FUZ34MComparison of PL7 applications9Type of softwarePL7 DIF for comparison of applicationsPL7 DIF software extensionFor PL7 Pro, TSX Micro/PremiumType of license Single (1 station) Site (> 10 stations)Reference TLXCDPL7DIF42 TLXOSPL7DIF42Availability of control systems based on Premium platforms10Type of softwareWarm Standby software extensionType of licenseReferenceWarm Standby redundantFor PL7 Junior/ProSingle (1 station)TLXCDWSBYP40F / E3/48Other versions: please consult our Customer Care Centre.


Programming softwareFor Modicon Quantum, MomentumType of softwareConcept is the IEC programming software for the Momentum and Quantum range of PLCs. It providesadvanced Microsoft Windows based tools that deliver a multi-language development environment forcontrol system programming.Uses familiar, standardized editors, bundled in a single application to create and integrate PLC control,communication and diagnostic logic.Five IEC editors give users the freedom to choose the programming language that fits their applicationrequirements: Function Block Diagram (FBD), Ladder Diagram (LD), Sequential Function Chart (SFC),Structured Text (ST) and Instruction List (IL).Concept for Quantum/Momentum platforms1Type of license version 2.6 Single (1 station) Group (3 stations) 10 users (10 stations) SiteSoftware references Concept S 372SPU47101V26 – – –Concept M 372SPU47201V26 – – –Concept XL 372SPU47401V26 372SPU47411V26 372SPU47421V26 372SPU47431V26Update references Concept S (3) 372ESS47101 – – –Concept M (3) 372ESS47201 – – –Concept XL (3) 372ESS47401 372ESS47403 372ESS47410 372ESS47400(3) From an earlier software version.23Specialist toolsEF/EFB function development software in C languageType of softwareConcept EFB ToolkitType of license Version 2.6 Upgrade version 2.6Reference Software package 332SPU47001V26 372ESS47001Concept service version limited to application loadingType of softwareConcept Application LoaderType of license Version 2.6Reference Software package 372SPU47701V26Software for designing and generating batch/process applicationsType of softwareUnity UAG (Unity Application Generator)Type of license version 3.0 Single (1 station) SiteReference Medium Software package UAGSEWMFUCD22 UAGSEWMFFCD22Large Software package UAGSEWLFUCD22 UAGSEWLFFCD224567Type of softwareProWORX for Modicon Quantum, MomentumProWORX 32 is the flexible, easy-to-use cross-platform LL984-programming software for Modicon rangePLCs. It gives you the power to program your Modicon controllers online or offline, manage your I/Osubsystems, and analyze your plant’s activity in real-time, all in a familiar Windows environment.ProWORX 32 provides client/server capabilities to organize user-groups and -rights, store projects at acentral location and realize office-plant floor bridging.The project emulator provides the ability to test projects prior to running them in the PLC run-timeenvironment to ensure your system will run at peak efficiency.ProWORX for Quantum/Momentum platforms89Type of license version 2.1 Single (1 station) Group (3 stations) Multi-user (10 stations) SiteSoftware references ProWORX 32 Server 372SPU78001PSEV – – –ProWORX 32 Suite 372SPU78001PSSV – – –ProWORX 32 Client, Full Dev. 372SPU78001PDEV 372SPU78001PSTH 372SPU78001PSTE 372SPU78001SITEProWORX 32 Online 372SPU78101PONL – – –ProWORX 32 Lite 372SPU71001PLDV 372SPU71001PLTH 372SPU71001PLTE –Upgrade to ProWORX 32references (4) 372SPU78401LPUP 372SPU78401LPTH 372SPU78401LPTE –(4) Only possible for customers, who are “up-to-date” with CSP (continuing support program)10Other versions: please consult our Customer Care Centre.3/49


Vijeo CitectSCADA software1TypeSupervisory control and data acquisition (SCADA) software23CompatibilityAll Schneider Electric automation platforms and third party devicesOperating system Windows XP, Windows Vista and Windows server 2003 & 2005Versions The development licence (without network connectivity) allows free communication with PLCs for 10minutes at a time.Vijeo Citect full server licences are available in 75 points, 150 points, 500 points, 1500 points, 5000points, 15000 points and unlimited pointsVijeo Citect Lite (without network connectivity) is available in 100 - 1200 pointsReferencesPlease contact your local sales representative4Vijeo HistorianVijeo Citect56Vijeo DesignerMagelis XBT GTMagelis Smart & Compact iPCTwido Modicon M340Magelis Compact & iPCModular iPCPCModicon Premium Modicon QuantumVijeo Suite; The best HMI/SCADA offer.Designed to offer optimum integrationwith Schneider Electric equipment.7Vijeo Citect is a SoCollaborative software for operating and monitoring. With its powerful visualisation capabilities and operational features, it delivers actionable insight faster,enabling operators to respond quickly to process disturbances, thereby increasing their effectiveness. Its easy-to-use configuration tools and powerful features enable you toquickly develop and deploy solutions for any size application.8910Benefits at a glance:• Full-redundancy for reliable architecture: Vijeo Citect’s in-built redundancy greatly reduces lost data and downtime, tolerating failure anywhere in your system.• Powerful graphics: Vijeo Citect lets you develop true colour, easy-to-use graphics that provide the operator with an intuitive, consistent user interface.• Intuitive Process Analysis tool: Vijeo Citect Process Analyst is an intuitive process analysis tool that sits directly in the SCADA system, providing a complete story ofyour plant and delivering actionable insight to the operators faster, thereby improving their efficiency and productivity.• Object-based configuration for rapid development: Developing your control system is made quick and easy by Vijeo Citect’s object-based configuration tools suchas page templates, Genies, Super Genies, and SpeedLink.• Engineering with ease: Vijeo Citect offers flexible and targeted system engineering tools to help you be more efficient. It accelerates your control system configurationprocess, significantly reducing your engineering time and costs and minimising your project risk.3/50Other versions: please consult our Customer Care Centre.


Vijeo HistorianReporting softwareTypeHistorian software1CompatibilityAll Schneider Electric automation platforms and third party devicesOperating system Windows XP, Windows Vista and Windows server 2003 & 2005References CD-ROM PCPlease contact your local sales representative2OPC MS SQL Server/Oracle3S tCADA Sys emHistorian4Vijeo Historian Server52005 ReportingServicesMES Process Analyst Microsoft SQL ServerHistorian ReportsDeploymentManagerVijeo HistorianExcel ClientVijeo HistorianWeb ClientVijeo Historian is a SoCollaborative software for the information management. It comprises the historian and portal functionalities of the solution, enabling you to accurately storedata for long-term reporting while connecting your production and business systems through its active data transfers and simple, easy-to-use reporting.6789Benefits at a glance:• Business systems integration: Vijeo Historian reduces the complexity and cost of bridging the divide between senior management and plant operations through its simple,easy-to-use interface and its active data transfers that push data from the control systems up to the business systems.• An open data store: Vijeo Historian utilises 100% Microsoft SQL Server 2005 as its embedded historical data store. Its open, industry-standard technology and trusted securityintegrate effortlessly into your business in a way that lowers your total cost of ownership.• Enterprise-wide reporting: A range of reports can be produced using a convenient built-in historian in the familiar, open Microsoft user interface. Vijeo Historian also comeswith a standard set of pre-configured reports, simplifying basic alarm and tag reporting.• Alarm management: Pre-configured alarm reports based on the EEMUA (Engineering Equipment & Materials Users Association) 191 alarm management guidelines.• Going ‘green’ with the energy reports: Energy reports help you perform a comprehensive energy assessment of your plant to determine how much energy is being consumedand how much could potentially be saved.10Other versions: please consult our Customer Care Centre.3/51


Altistart and AltivarUse Altistart soft starters to start your motorssmoothly and so protect the mechanics of yourequipment. With the Altivar range of variablespeed drives, you save energy and manage thespeed of your motors to optimise and enhanceproductivity in your installations.The Altistart, Altivar and Lexium rangesincrease the efficiency of your machines,reduce their energy consumption andoptimise their kinematics. Easy to install,offering intuitive programming andextensive communication options, theyare easily integrated into your controlsystem architectures.LexiumControllers, drives, motors and linearpositioning axes: Schneider Electricoffers a complete range of motioncontrol products and solutionssuitable for even the most specialisedapplications. Designed with maximumsimplicity in mind throughout amachine’s entire service life, the Lexiumrange reduces costs and optimisesproductivity.


Motion controlThis document is a selection ofthe top selling products.1Soft starters and variable speed drivesSelection guide ......................................................................................................... 4/3 and 4/7StartersAltistart 01 .................................................................................................................. 4/8 and 4/9Altistart 22 ...............................................................................................................4/10 and 4/11Altistart 48 .............................................................................................................. 4/12 and 4/13DrivesAltivar 12 ............................................................................................................................... 4/14Altivar 212 ............................................................................................................................. 4/15Altivar 312 ............................................................................................................................. 4/16Altivar 31C ............................................................................................................................. 4/17Altivar 32 ............................................................................................................................... 4/18Altivar 61, 61Q, 61 Plus ............................................................................................. 4/19 to 4/25Specific cards and extension for pumping and ventilation machines ..................... 4/26 and 4/27Altivar 71, 71Q, 71 Plus ............................................................................................. 4/28 to 4/34Altivar LIFT ............................................................................................................................ 4/35Specific cards and extension for complex and high power machines .................... 4/36 and 4/37Accessories and options (Altistart et Altivar) ......................................... 4/38 and 4/3923456Controllers, drives, motors and linear motion axesSelection Guide ....................................................................................................... 4/40 to 4/42Motion Controller Lexium LMC ..................................................................................... 4/43Servo drives, servo motors Lexium 32 and accessories ....................... 4/44 to 4/51Lexium 32 servo drivesLexium BMH and Lexium BSH servo motorsStepper Drives and Stepper Motors Lexium SD .................................................... 4/52Lexium SD2/Lexium SD3 stepper drivesLexium BRS2/Lexium BRS3 stepper motorsIntegrated Drives Lexium IL ............................................................................... 4/53 to 4/55Lexium ILA/ILE/ILS/ILT/ILPSingle axes and multi-axis Systems Linear Motion .............................. 4/56 and 4/57Lexium PAS/CAS/TAS/MAX789104/1


1HighlightsAltivar 32More than 150 application-specificfunctions23The Altivar 32 range of variable speed drives controlsasynchronous and synchronous motors rated from 0.18 to 15 kWoperating in open loop mode in complex machines:• Compact, vertical and slim format (45 mm)• Integrated function blocks for creating simple control systemfunctions (timers, counters, comparators, etc.)• Machine safety functions integrated as standard (STO, SLS, SS1)• Open design: communicates with most industrial networksFor more information, see page 4/1845678910Lexium 32Inspired by SimplicityThe Lexium 32 servo drive range (0.15 to 7 kW) is a drive systemdesigned for applications where high precision and dynamicpositioning are critical:• Suitable for packaging, materials processing (cutting, turning,milling, etc.) and handling, printing and textile applications• 3 servo drive families and two types of servo motor available• Simplified engineering: motor sizing, CAD and cabinet drawings,support for PLCopen libraries and SoMove setup software• Integrated “Safe Torque Off” function• Quick integration: wide selection of fieldbus modulesFor more information, see page 4/44Ultra slim and ultra powerfulPractical and innovative, the Altivar 32 and Lexium 32 ranges can helpreduce the size of your enclosures by as much as 40%.• Extra slim book format• Easy to configure and setup with SoMove software• Packed with common software tools, accessories and functions• Homogeneous mounting and wiring systems• High-performance communication system• Built-in Bluetooth as standard• Can be configured with the power off in its original packaging:configurations can be transferred remotely via mobile phone usingSoMove Mobile software4/2Other versions: please consult our Customer Care Centre.


Selection guideStarters - Low voltageSimple machinesCApplications:CApplications:Complex machines/Special machinesCApplications:Compressors, fans,pumps, conveyors, carwash gantries, etc.Pumps, fans, turbines,compressors, conveyors,conveyor belts, liftingscrews, escalators, etc.Pumps, high inertiafans and machines,compressors, conveyors,agitators, mixers,escalators, etc.123Altistart 01 Altistart 22 Altistart 4845Soft start andSoft start/soft stop unitsSoft start/soft stop unitsSoft start/soft stop unitsDescription• Compact• Simple: easy mounting,wiring and adjustment• Efficient: Current peakslimitation on starting, reductionof mechanical shocks, increasedservice life for your machines• Energy saving• Innovative with its integratedBypass contactor for motors upto 315 kW• Cost-effective• Compact dimensions• Quick setup• Protection of motor andstarter• Energy saving• 3 controlled phases• Torque control system:controlled torque, prevention ofpressure surges and limiting oftemperature rises• Simple: quick setup• Protection of motor andstarter: thermal protection,phase loss detection, lockedrotor detection• Energy saving67Technical informationPower range for50…60 Hz supply0.37...15 kW 4... 400 kW 4...1200 kWVoltage Single-phase 110…480 V Three-phase 208…600 V Three-phase 208…690 VThree-phase 110…480 V Three-phase 230…440 VDrive/Output frequency – – –8Motor type Asynchronous Yes Yes YesSynchronous No No NoCommunication Integrated – Modbus ModbusAs an optionCan be used with TeSys Umotor starter-controller tocreate a complete motorstarter solution– DeviceNet, Fipio, PROFIBUS DP,Ethernet9Standards and certificationsIEC/EN 60947-4-2, C-Tick, CSA,UL, CEIEC/EN 60947-4-2, C-Tick, CSA,UL, CE, GOST, CCCClass A EMCIntended use Buildings, Simple machines. Machines, Infrastructures and BuildingsIEC/EN 60947-4-2, C-Tick, CSA,UL, CE, DNV, GOST, CCC, NOM,SEPRO and TCFClasses A and B EMC10Other versions: please consult our Customer Care Centre.4/3


Selection guideStandard drives - Low voltageSimple machines1234CApplications:• Simple machines forindustry (small handlingapplications, packaging,pumps, fans, etc.)• Simple consumermachines (access barriers,rotating advertisinghoardings, medical beds,treadmills, dough mixers,etc.)• Other types of application:- Mobile machines andsmall appliances equippedwith a power socket- Applications whichtraditionally use othersolutions (2-speed DCmotors, mechanical drives,etc.).C Applications:Simple industrial machines(material handlingand packaging, textilemachines, specialmachines, pumps andfans).C Applications:Simple industrialmachines (materialhandling and packaging,textile machines, specialmachines, pumps andfans).Altivar 12 Altivar 312 Altivar 31C IP555Variable speed drives for smallmachines with 240 V three-phaseasynchronous motorVariable speed drives for threephaseasynchronous motorsVariable speed drives for threephaseasynchronous motors formachines in harsh environments.678DescriptionTechnical informationPower range for50…60 Hz supplyVoltage• Compact• Easy to set up(Plug & Play)• Reliable, cost-effectivesolution for compact machines• Open: large number ofcommunication cards availableas options• User-friendly: simplifiedinterface• Autotuning:maximum performance0.18...4 kW 0.18...15 kW 0.18...15 kWSingle-phase 100…240 VThree-phase 200…240 VSingle-phase 200…240 VThree-phase 200…600 VDrive/Output frequency 0.5…400 Hz 0.5…500 Hz 0.5…500 Hz• Rugged even in the most hostileenvironments:- Installed as close as possible tothe motor- Integrated functions for applicationsrequiring IP55 degree of protection- Modbus and CANopencommunication protocols• Flexibility to adapt to each machine:- Customisable depending on themodel- Easy configurationSingle-phase 200…240 VThree-phase 380…500 V9Motor type Asynchronous Yes Yes YesSynchronous No No NoCommunication Integrated Modbus Modbus and CANopen Modbus and CANopenAs an option – CANopen Daisy chain,DeviceNet, PROFIBUS DP,Modbus TCP, FipioDeviceNet, Ethernet TCP/IP,Fipio, PROFIBUS DP10Standards and certifications IEC/EN 61800-5-1, IEC/EN 61800-3 (environments 1 and 2,categories C1 to C3)CE, UL, CSA, C-Tick, GOST, NOMIEC/EN 61800-5-1, IEC/EN61800-3 (environments 1 and 2,categories C1 to C3)CE, UL, CSA, C-Tick, GOSTIntended useMachines4/4Other versions: please consult our Customer Care Centre.


Complex machinesC Applications:Industrial machines:hoisting, packaging,material handling,special machines (woodworkingmachines, metalprocessing machinery,etc.).Complex machines/Special machinesC Applications:High performanceapplications:• Material handling• Hoisting• Wood-working machines• Process machinery• Textile machines• PackagingC Applications:High performanceapplications:• Material handling• Hoisting• Wood-working machines• Process machinery• Textile machines• PackagingPumps andFansC Applications:Range specifi cally for highperformance pumps andfans for the industrial andbuilding markets.C Applications:Pumping and ventilationmachines in harshenvironment123Altivar 32 Altivar 71 Altivar 71Q Altivar 61 Altivar 61Q45Variable speed drives forasynchronous motors andopen-loop synchronous motors• Compact: "Book" format• Integrated Safety function compliantto IEC 61508 SIL3 and PL-e• Open: communication cardsavailable as options• Integrated programmablelogic functions• Simple setup· Energy saving : Control ofenergy efficient permanentmagnet synchr onous motorsFor three-phase synchronousand asynchronous motors.Constant torque applications.• Wide range• Quick start-up and easydiagnostics: multi-languagegraphic display terminal• Open to most industrialcommunication buses• Integrated safety functions• Motor control: highperformancein open-loop andclosed loop modeWater-cooled variable speeddrives for three-phase synchronousand asynchronous motors.Constant torque applications.• Improved robustness withwater cooling• Efficient cooling system reducedneed of air conditioning• Long time operation withoutmaintenance• Excellent protection againstcorrosion due to stainless steelcooling pipes• Very high starting torque forfrequent start-up applicationsVariable speed drives for threephaseasynchronous motors.Variable torque applications.• Wide range• Easy setup and diagnosticswith the multi-language graphicdisplay terminal• Open to the maincommunication buses0.18...15 kW 0.37...630 kW 90...630 kW 0.37...800 kW 110…800 kWSingle-phase 200…240 VThree-phase 380…480 VSingle-phase 200…240 VThree-phase 200…690 V0.1…599 Hz 0…599 Hz up to 37 kW /200…240V and 380…480V0…500 Hz for the rest of the rangeThree-phase 380...480 VThree-phase 500…690 VSingle-phase 200…240 VThree-phase 200…690 V0…500 Hz 0.1…599 Hz up to 37 kW /200…240V and 380…480V0.1…500 Hz for the rest of the rangeWater-cooled variable speeddrives for three-phase asynchronousand synchronous motors.Variable torque applications• Improved robustness withwater cooling• Efficient cooling system reducedneed of air conditioning• Prolonged maintenance-freeoperational life• Excellent protection againstcorrosion due to stainless steelcooling pipesThree-phase 380...480 VThree-phase 500…690 V0.1…500 HzYes Yes Yes Yes YesYes Yes Yes Yes YesModbus and CANopen Modbus and CANopen Modbus et CANopen Modbus and CANopen Modbus et CANopenEtherNet/IP, Modbus TCP,PROFIBUS DP V1, EtherCAT,DevicenetModbus TCP, Fipio,Modbus/Uni-Telway, ModbusPlus, EtherNet/IP, DeviceNet,PROFIBUS DP, PROFIBUS DP V1,INTERBUS S, CC-Link,Modbus TCP, Fipio, Modbus/Uni-Telway, Modbus Plus, EtherNet/IP,DeviceNet, PROFIBUS DP, PROFIBUSDP V1, INTERBUS S, CC-Link,Modbus TCP, Fipio, Modbus/Uni-Telway, Modbus Plus, EtherNet/IP,DeviceNet, PROFIBUS DP, PROFIBUSDP V1, INTERBUS S, CC-Link,Lonworks, METASYS N2, APO-GEE FLN P1, BACnetHVAC protocols : LonWorks, BACnet,METASYS N2,APOGEE FLN P1Industrial protocols: Modbus TCP,Modbus/Uni-Telway, Fipio, Modbus Plus,PROFIBUS DP, PROFIBUS DP V1, DeviceNet,Ethernet IP, CC-Link, INTERBUS6789IEC/EN 61800-5-1, IEC/EN 61800-3(environments 1 and 2, CategoriesC2 and C3), UL508C, EN 954-1Category 3, ISO/EN 13849-1/- 2Category 3 (PLd), IEC 61800-5-2, IEC61508 (parts 1&2) level SIL1 SIL2 SIL3,draft standard EN 50495E, CE, UL,CSA, C-Tick, GOST, NOM.MachinesIEC/EN 61800-3, EN 55011,EN 55022, CSA, UL, C-TICK,CE, NOM, DNV, GOSTMachines, industrial processesand infrastructuresIEC/EN 61800-3, EN 55011, EN55022, CSA, UL, C-TICK, CE,NOM, DNV, GOSTMachines, industrial processesor infrastructuresIEC/EN 61800-3, EN 55011,EN 55022, CSA, UL, C-TICK,CE, NOM, DNV, GOSTBuildings and infrastructuresIEC/EN 61800-3, EN 55011, EN55022, CSA, UL, C-TICK, CE,NOM, DNV, GOSTBuilding or infrastructures10Other versions: please consult our Customer Care Centre.4/5


Selection guideSpecialized drives - Low voltageHVACLiftsC Applications:C Applications:1Range specifically for HVAC applications(heating, ventilation, air conditioning) inbuildings.Lifts23Altivar 212Altivar LIFT4Variable speed drives for three-phase asynchronousmotors.Variable torque building HVAC applications.Variable speed drives for lifts.56Description• Compact size: side-by-side mounting• Simplicity : Dedicated HVAC functions and remotegraphic keypad option• Openness : Integrated communications for buildingmanagement systems• EMC filters built-in• Reduction of the total harmonic distortionTHDI


Integrated variable speed control solutionsPumps and FansLow voltageC Applications:Pumps and FansMedium voltageC Applications:Complex machines/Specialmachines Low voltageC Applications:Complex machines/Specialmachines Medium voltageC Applications:• Fans• Pumps• Compressors• Screw feeders• Energy: fans, pumps, turbinestarters• Oil and gas: pumps,compressors, air blowers,extruders• Mines and Minerals:conveyors, crushers, fans,pumps• Water treatment: pumps,air blowers.• Fans• Pumps• Compressors• Screw feeders• Energy: fans, pumps, turbinestarters• Oil and gas: pumps,compressors, air blowers,extruders• Mines and Minerals: conveyors,crushers, fans, pumps• Water treatment: pumps,air blowers.12Altivar 61 Plus Altivar 1100 Altivar 71 Plus Altivar 100034High power low voltage variable speed drivesfor buildings and infrastructures.Variable torqueA simple, open range:• Greater flexibility: numerous possibleoptions and communication on most industrialnetworks• Easy configuration• Ready to useMaximum safety: the Altivar Plus range hasa cooling system and components that havebeen tested in extreme conditions.Time savings on:• Creating quotes• Placing orders• Installation and start-upMedium voltage variable speeddrives for asynchronous motors(quotation on request)Environmentally-friendly and Costeffective:• Perfect integration in the line supply• No disturbance of the motor and thedriven load• High efficiencyEasy to install and set upCompactHigh power low voltage variable speed drivesfor industry.Constant torqueA simple, open range:• Greater flexibility: numerous possibleoptions and communication on most industrialnetworks• Easy configuration• Ready to useMaximum safety: the Altivar Plus range hasa cooling system and components that havebeen tested in extreme conditions.Time savings on:• Creating quotes• Placing orders• Installation and start-up90…2400 kW 0.3…10.5 MW 90…2000 kW 0.5…10 MWThree-phase 380…690 V0.1…500 Hz3,3 kV6,6 kV10 kVStandard : 0,2…60 HzOption : 0,2…120 HzThree-phase 380…690 VMedium voltage variable speed drivesfor asynchronous motors (quotation onrequest)High efficiencyFor use in harsh environmentsOpen to all communication networks2.4 kV3.3 kV0…500 Hz Standard: 5…70 HzOption: 5…140 Hz2 and 4 2 2 and 4 2 and 4Air or water cooled Air cooled Air or water cooled Air or water cooledIP23/IP54IP55 (water cooled)IP31IP41 (option)IP23/IP54IP55 (water cooled)IP41 (air cooled)IP54 (water cooled)Yes Yes Yes YesYes No Yes NoModbus and CANopen PROFIBUS, Modbus Modbus and CANopen Ethernet, PROFIBUS, ModbusModbus TCP, Fipio, Modbus/Uni-Telway, ModbusPlus, EtherNet/IP, DeviceNet, PROFIBUS DP,PROFIBUS DP V1, INTERBUS S, CC-Link, Lonworks,METASYS N2, APOGEE FLN P1, BACnetEthernet, Devicenet, CANopen, etc. Modbus TCP, Fipio, Modbus/Uni-Telway,Modbus Plus, EtherNet/IP, DeviceNet,PROFIBUS DP, PROFIBUS DP V1,INTERBUS S, CC-LinkDevicenet, CANopenIEC/EN 61800-5-1, IEC/EN 61800-3(environments 1 and 2), IEC/EN 61000-4-2,-4-3, -4-5, -4-6 (level 3), IEC/EN 61000-4-4(level 4), IEC/EN 60529, IEC 60721-3-3 class3C2 and 3S2, CE. DNV, GOSTIEC/EN 61800-5-1, IEC/EN 61800-4,IEC/EN 61800-3 (environnements 1and 2, catégories C1 to C3), IEEE519, IEC/EN 60204-11 andIEC/EN 60529IEC/EN 61800-5-1, IEC/EN 61800-3 (environments1 and 2), IEC/EN 61000-4-2,-4-3, -4-5, -4-6 (level 3), IEC/EN 61000-4-4(level 4), IEC/EN 60529, IEC 60721-3-3 class3C2 and 3S2, CE. DNV and GOSTBuildings and infrastructures Infrastructures Machines, industrial processesand infrastructuresIEC/EN 61800-5-1, IEC/EN 61800-4,IEC/EN 61800-3 (environments 1 and 2,categories C1 to C3), CEMachines, industrial processesand infrastructures5678910Other versions: please consult our Customer Care Centre.4/7


Altistart 010.37…15 kWSimple machinesStarters123456Dimensions (in mm)width x height x depthATS01 N103FT/N106 FT 22.5 x 100 x 100.4N109FT/N112 FT/N125 FT45 x 124 x 130.7N206pp/N209pp/N212ppN222pp/N232pp 45 x 154 x 130.7Type Soft start units Soft start/soft stop unitsMotor power 0.37 to 11 kW 0.75 to 15 kWDegree of protectionIP20Reduction of current peaks 2 controlled phases 2 controlled phasesAdjustable starting time 1…5 s 1…10 sAdjustable deceleration time No: freewheel stop Yes: 1... 10 sAdjustable breakaway torque30…80% of DOL motor starting torqueLogic inputs – 3 logic inputs (start, stop and startup boost)Logic outputs – 1 logic outputRelay outputs – 1 relay outputControl supply voltage 110... 220 VAC ± 10%, 24 VDC ± 10% Built into the starterSupply voltageSingle-phase 110…230 VMotor power230 V Nominal currentkW(IcL)0.37 3 A ATS01N103FT0.75 6 A ATS01N106FT1.1 9 A ATS01N109FT1.5 12 A ATS01N112FT2.2 25 A ATS01N125FTSupply voltage Three-phase 110…480 V Three-phase 200…240 V Three-phase 380…415 V Three-phase 440…480 VMotor power210 V 230 V 400 V 460 V Nominal currentHP kW HP kW HP (IcL)– 0.37-0.55 0.5/– 1.1 0.5-1.5 3 A ATS01N103FT – – –0.5 0.75-1.1 1-1.5 2.2-3 2-3 6 A ATS01N106FT ATS01N206LU ATS01N206QN ATS01N206RT1 1.5 2 4 5 9 A ATS01N109FT ATS01N209LU ATS01N209QN ATS01N209RT1.5 2.2 3 5.5 7.5 12 A ATS01N112FT ATS01N212LU ATS01N212QN ATS01N212RT– 4-5.5 5-7.5 7.5-11 10-15 22 A – ATS01N222LU ATS01N222QN ATS01N222RT2-3 3-4-5.5 5-7.5 7.5-9-11 10-15 25A ATS01N125FT – – –– 7.5 10 15 20 32 A – ATS01N232LU ATS01N232QN ATS01N232RT789104/8Other versions: please consult our Customer Care Centre.


Starters with TeSys model UDimensions (in mm)width x height x depthATSU01 N206LT/N209LT/N212LT 45 x 124 x 130.7N222LT/N232LT 45 x 154 x 130.7TypeSoft start/soft stop unitsMotor power0.75 to 15 kWDegree of protectionIP20Reduction of current peaksYesAdjustable starting and stopping times1…10 sAdjustable breakaway torque30.... 80% of DOL motor starting torqueLogic inputs3 logic inputs (start, stop and startup boost)Logic outputs1 logic outputRelay outputs1 relay outputControl supply voltage 24 VDC, 100 mA, ± 10%ReferencesSoft start/soft stop TeSys starter-controllerPower connectorunitsmodel UPower base Control unit (1) between ATSU andTeSys model USupply voltageThree-phase 200…480 VMotor power230 V 400 V 460 V NominalkW HP kW HPcurrent (IcL)0.75 1 1.5 2 6 A ATSU01N206LT LUB12 LUCp05BL VW3G41041.1 1.5 2.2/3 3 6 A ATSU01N206LT LUB12 LUCp12BL1.5 2 – 5 9 A ATSU01N209LT LUB12 LUCp12BL VW3G4104– – 4 – 9 A ATSU01N209LT LUB12 LUCp12BL2.2 3 5.5 7.5 12 A ATSU01N212LT LUB12 LUCp12BL VW3G41043 – – – 12 A ATSU01N212LT LUB32 LUCp18BL4 5 7.5 10 22 A ATSU01N222LT LUB32 LUCp18BL VW3G41045.5 7.5 11 15 22 A ATSU01N222LT LUB32 LUCp32BL7.5 10 15 20 32 A ATSU01N232LT LUB32 LUCp32BL VW3G4104(1) To compose your reference, replace p in the reference with: «A» for a standard control unit, «M» for a multifunction unit and «B» for an advanced unit.12345678910Other versions: please consult our Customer Care Centre.4/9


Altistart 224…400 kWSimple machinesSoft start/soft stop units1Dimensions (en mm)Size A: 130 x 265 x 169Size B: 145 x 295 x 207Size C: 150 x 356 x 229Size D: 206 x 425 x 299Size E: 304 x 455 x 340width x height x depthSupply voltage Three-phase 208…600 V Three-phase 230…440 V234Protection Degree of protection IP20: for ATS 22D17pppD88 startersIP00: for ATS 22C11pppC59 starters (protection of terminals available as an option)Motor thermal protection Class 10, 20 or 30Drive Number of controlled phases 3Types of controlConfi gurable voltage ramp, torque rampOperating cycleStandardFunctionsIntegrated Bypass contactorNumber of I/O Analog inputs 1 PTC probeLogic inputs 3Logic outputs –Analog outputs –Relay outputs 2DialogueIntegrated display terminal, SoMove Lite setup softwareCommunication Integrated ModbusStandards and certifi cationsIEC/EN 60947-4-2, class A EMC, CE, UL, CSA, C-Tick, GOST, CCCMotor connectionPossible to connect the starter in the motor deltaconnection56789104/10Other versions: please consult our Customer Care Centre.


1Connection in the motor power supply lineSoft start/soft stop unit 230…440 V - 50/60 HzMotorPower indicated on rating plate230 V 400 V 440 V Nominal currentkW kW kW starter (IcL) Reference Size4 7.5 7.5 17 ATS22D17Q Size A7.5 15 15 32 ATS22D32Q Size A11 22 22 47 ATS22D47Q Size A15 30 30 62 ATS22D62Q Size B18.5 37 37 75 ATS22D75Q Size B22 45 45 88 ATS22D88Q Size B30 55 55 110 ATS22C11Q Size C37 75 75 140 ATS22C14Q Size C45 90 90 170 ATS22C17Q Size C55 110 110 210 ATS22C21Q Size D75 132 132 250 ATS22C25Q Size D90 160 160 320 ATS22C32Q Size D110 220 220 410 ATS22C41Q Size D132 250 250 480 ATS22C48Q Size E160 315 355 590 ATS22C59Q Size E23456Connection in the motor power supply lineSoft start/soft stop unit 230…600 V - 50/60 HzMotorPower indicated on rating plate230 V 400 V 440 V 500 V Nominal currentkW kW kW kW starter (IcL) Reference Size4 7.5 7.5 9 17 ATS22D17S6 Size A7.5 15 15 18.5 32 ATS22D32S6 Size A11 22 22 30 47 ATS22D47S6 Size A15 30 30 37 62 ATS22D62S6 Size B18.5 37 37 45 75 ATS22D75S6 Size B22 45 45 55 88 ATS22D88S6 Size B30 55 55 75 110 ATS22C11S6 Size C37 75 75 90 140 ATS22C14S6 Size C45 90 90 110 170 ATS22C17S6 Size C55 110 110 132 210 ATS22C21S6 Size D75 132 132 160 250 ATS22C25S6 Size D90 160 160 220 320 ATS22C32S6 Size D110 220 220 250 410 ATS22C41S6 Size D132 250 250 315 480 ATS22C48S6 Size E160 315 355 400 590 ATS22C59S6 Size EThe Altistart 22 soft start/soft stop unit is also available with a 110 VDC control power supply, reference ATS22…S6U78910Other versions: please consult our Customer Care Centre.4/11


Altistart 484…1200 kWPumping and ventilation machinesSoft start/soft stop units123456789Dimensions (in mm)width x height x depthATS48 D17Q to D47Q Size A: 160 x 275 x 190D62Q to C11Q Size B: 190 x 290 x 235C14Q to C17Q Size C: 200 x 340 x 265C21Q to C32Q Size D: 320 x 380 x 265C41Q to C66Q Size E: 400 x 670 x 300C79Q to M12Q Size F: 770 x 890 x 315Supply voltage Three-phase 230…415 V (1)Type of application Standard Severe (2)Starter control supply voltage220…415 VProtection Degree of protection IP20: ATS48D17p to ATS48C11p startersIP00: ATS48C14p to ATS48M12p startersMotor thermal protection Class 10 Class 20 and 30EMC Class A On all startersClass BOn all starters up to 170 AStarting modeTorque control (patented TCS: Torque Control System)I/O Analog inputs 1 PTC probeLogic inputs4 logic inputs, 2 of which are configurableLogic outputs2 configurable logic outputsAnalog outputs1 analog outputRelay outputs3 relay outputs, 2 of which are configurableDialogueIntegrated or remote display terminal (in option), PowerSuite software workshopCommunication Integrated ModbusAs an optionDeviceNet, Ethernet, Fipio, PROFIBUS DPMotor power230 V 400 V Nominal currentkW kW (IcL)3 5.5 12 A – ATS48D17Q Size A4 7.5 17 A ATS48D17Q Size A ATS48D22Q Size A5.5 11 22 A ATS48D22Q Size A ATS48D32Q Size A7.5 15 32 A ATS48D32Q Size A ATS48D38Q Size A9 18.5 38 A ATS48D38Q Size A ATS48D47Q Size A11 22 47 A ATS48D47Q Size A ATS48D62Q Size B15 30 62 A ATS48D62Q Size B ATS48D75Q Size B18.5 37 75 A ATS48D75Q Size B ATS48D88Q Size B22 45 88 A ATS48D88Q Size B ATS48C11Q Size B30 55 110 A ATS48C11Q Size B ATS48C14Q Size C37 75 140 A ATS48C14Q Size C ATS48C17Q Size C45 90 170 A ATS48C17Q Size C ATS48C21Q Size D55 110 210 A ATS48C21Q Size D ATS48C25Q Size D75 132 250 A ATS48C25Q Size D ATS48C32Q Size D90 160 320 A ATS48C32Q Size D ATS48C41Q Size E110 220 410 A ATS48C41Q Size E ATS48C48Q Size E132 250 480 A ATS48C48Q Size E ATS48C59Q Size E160 315 590 A ATS48C59Q Size E ATS48C66Q Size E– 355 660 A ATS48C66Q Size E ATS48C79Q Size F220 400 790 A ATS48C79Q Size F ATS48M10Q Size F250 500 1000 A ATS48M10Q Size F ATS48M12Q Size F355 630 1200 A ATS48M12Q Size F –(1) Possible to connect the starter in the motor delta connection(2) Starting time greater than 30 seconds (fans, high inertia machines and compressors)104/12Other versions: please consult our Customer Care Centre.


Soft start/soft stop unitsDimensions (in mm)width x height x depthATS48 D17Y to D47Y Size A: 160 x 275 x 190D62Y to C11Y Size B: 190 x 290 x 235C14Y to C17Y Size C: 200 x 340 x 265C21Y to C32Y Size D: 320 x 380 x 265C41Y to C66Y Size E: 400 x 670 x 300C79Y to M12Y Size F: 770 x 890 x 315Supply voltage Three-phase 208…690 V (1)Type of application Standard Severe (2)Starter control supply voltage110…230 VCharacteristicsIdentical to 230…415 V startersMotor powerNominal208 V 230 V 460 V 575 V 230 V 400 V 440 V 500 V 525 V 660 V 690 V currentHPkW(IcL)2 3 7.5 10 3 5.5 5.5 7.5 7.5 9 11 12 A – ATS48D17Y Size A3 5 10 15 4 7.5 7.5 9 9 11 15 17 A ATS48D17Y Size A ATS48D22Y Size A5 7.5 15 20 5.5 11 11 11 11 15 18.5 22 A ATS48D22Y Size A ATS48D32Y Size A7.5 10 20 25 7.5 15 15 18.5 18.5 22 22 32 A ATS48D32Y Size A ATS48D38Y Size A10 – 25 30 9 18.5 18.5 22 22 30 30 38 A ATS48D38Y Size A ATS48D47Y Size A– 15 30 40 11 22 22 30 30 37 37 47 A ATS48D47Y Size A ATS48D62Y Size B15 20 40 50 15 30 30 37 37 45 45 62 A ATS48D62Y Size B ATS48D75Y Size B20 25 50 60 18.5 37 37 45 45 55 55 75 A ATS48D75Y Size B ATS48D88Y Size B25 30 60 75 22 45 45 55 55 75 75 88 A ATS48D88Y Size B ATS48C11Y Size B30 40 75 100 30 55 55 75 75 90 90 110 A ATS48C11Y Size B ATS48C14Y Size C40 50 100 125 37 75 75 90 90 110 110 140 A ATS48C14Y Size C ATS48C17Y Size C50 60 125 150 45 90 90 110 110 132 160 170 A ATS48C17Y Size C ATS48C21Y Size D60 75 150 200 55 110 110 132 132 160 200 210 A ATS48C21Y Size D ATS48C25Y Size D75 100 200 250 75 132 132 160 160 220 250 250 A ATS48C25Y Size D ATS48C32Y Size D100 125 250 300 90 160 160 220 220 250 315 320 A ATS48C32Y Size D ATS48C41Y Size E125 150 300 350 110 220 220 250 250 355 400 410 A ATS48C41Y Size E ATS48C48Y Size E150 – 350 400 132 250 250 315 315 400 500 480 A ATS48C48Y Size E ATS48C59Y Size E– 200 400 500 160 315 355 400 400 560 560 590 A ATS48C59Y Size E ATS48C66Y Size E200 250 500 600 – 355 400 – – 630 630 660 A ATS48C66Y Size E ATS48C79Y Size F250 300 600 800 220 400 500 500 500 710 710 790 A ATS48C79Y Size F ATS48M10Y Size F350 350 800 1000 250 500 630 630 630 900 900 1000 A ATS48M10Y Size F ATS48M12Y Size F400 455 1000 1200 355 630 710 800 800 – – 1200 A ATS48M12Y Size F –(1) Starter connection in the motor delta connection: up to 500 V only, add "S316" at the end of the reference(2) Starting time greater than 30 seconds (fans, high inertia machines and compressors)12345678910Other versions: please consult our Customer Care Centre.4/13


Altivar 120.18…4 kWSimple machinesUltra-compact drives123456Dimensions (in mm)width x height x depth1C1: 72 x 143 x 102.2 2F3: 105 x 143 x 131.21C2: 72 x 143 x 102.2 3F3: 140 x 184 x 141.21C3: 72 x 143 x 121.22C1: 105 x 142 x 156.22C2: 105 x 142 x 156.2Type of drive Single-phase Single-phase Three-phaseSupply voltage 120 V 240 V 240 VDegree of protectionIP20Drive Output frequency 0.5… 400 HzType of control Asynchronous motor U/F, sensorless flux vector control, quadratic U/FTransient overtorque 150…170Speed range 1 to 20Functions Number of functions 40Number of preset speeds 8Number of I/O Analog inputs 1 configurable analog inputLogic inputs4 assignable logic inputsAnalog outputs1 configurable analog outputRelay outputs1 protected relay logic outputDialogue Integrated or remote display terminal, SoMove software workshop, or mobile phone via Bluetooth ©Communication Integrated ModbusCards (available as an option)Reduction of current harmonicsEMC filter Integrated C1 EMCAs an optionMotor power kW/HP 0.18/0.25 ATV12H018F1 (1) 1C1 ATV12H018M2 (1) (2) 1C2 ATV12H018M3 (1) 1C30.37/0.5 ATV12H037F1 1C1 ATV12H037M2 (2) 1C1 ATV12H037M3 1C30.55/0.75 – ATV12H055M2 (2) 1C2 –0.75/1 ATV12H075F1 2C1 ATV12H075M2 (2) 1C2 ATV12H075M3 1C31.5/2 – ATV12HU15M2 (2) 2C2 ATV12H015M3 2F32.2/3 – ATV12HU22M2 (2) 2C2 ATV12H022M3 2F33/3 – – ATV12H030M3 3F34/5 – – ATV12H040M3 3F3(1) Because of the low heat dissipation, the ATV12H018.. is only supplied on a base plate(2) Also exists as a multipack789104/14Other versions: please consult our Customer Care Centre.


Altivar 2120.75…75 kWBuildingDrives for HVAC applicationsDimensions (in mm)width x height x depthIP21IP55T1A: 107 x 143 x 150 T1: 215 x 297 x 192T2A: 142 x 184 x 150 T2: 230 x 340 x 208T3A: 180 x 232 x 170 T3: 290 x 560 x 315T4A: 245 x 329.5 x 190 T4: 310 x 665 x 315T5A: 240 x 420 x 214 T5: 284 x 720 x 315T6A: 320 x 630 x 290 T5: 284 x 880 x 343T7A: 240 x 550 x 266 T5: 362 x 1000 x 364T8A: 320 x 630 x 290Type of drive IP21 IP55Supply voltage Three-phase 200…240 V 380…480 V 380…480 VDegree of protection IP21 and IP41 on the upper part IP55 drive available in two manufacturing variants,ATV212W…N4 C1 EMC or ATV212W…N4C C2 EMCOutput frequency0.5…200 HzType of controlKn 2 quadratic ratio, sensorless fl ux vector control, voltage/frequency ratio (2 points), energy saving ratioSpeed range 1 to 10I/O Analog inputs 1 switch-confi gurable current or voltage analog input and 1 voltage analog input, confi gurable as a PTCprobe inputLogic inputs3 programmable logic inputsAnalog outputs1 switch-confi gurable current or voltage analog outputRelay outputs2 relay logic outputsDialogue Integrated display terminal with local controls (1) or remote display terminal or PC software (3)CommunicationIntegratedModbus, APOGEE FLN P1, Metasys N2, BACnet(see page 4/11)As an optionLonWorksEMC filter Integrated – C2 EMC C2 EMC C1 EMCAvailable as an option C2 EMC C1 EMC – –Motor power kW/HP 0.75/1 ATV212H075M3X T1A ATV212H075N4 T1A ATV212W075N4 T1 ATV212W075N4C T11.5/2 ATV212HU15M3X T1A ATV212HU15N4 T1A ATV212WU15N4 T1 ATV212WU15N4C T12.2/3 ATV212HU22M3X T1A ATV212HU22N4 T1A ATV212WU22N4 T1 ATV212WU22N4C T13/– ATV212HU30M3X T2A ATV212HU30N4 T2A ATV212WU30N4 T2 ATV212WU30N4C T24/5 ATV212HU40M3X T2A ATV212HU40N4 T2A ATV212WU40N4 T2 ATV212WU40N4C T25.5/7.5 ATV212HU55M3X T3A ATV212HU55N4 T2A ATV212WU55N4 T2 ATV212WU55N4C T27.5/10 ATV212HU75M3X T3A ATV212HU75N4 T3A ATV212WU75N4 T2 ATV212WU75N4C T211/15 ATV212HD11M3X T4A ATV212HD11N4 T3A ATV212WD11N4 T3 ATV212WD11N4C T315/20 ATV212HD15M3X T4A ATV212HD15N4 T4A ATV212WD15N4 T3 ATV212WD15N4C T318.5/25 ATV212HD18M3X T4A ATV212HD18N4 T4A ATV212WD18N4 T4 ATV212WD18N4C T422/30 – ATV212HD22N4S T4A – –22/30 ATV212HD22M3X T5A ATV212HD22N4 (2) T5A ATV212WD22N4 T5 ATV212WD22N4C T530/40 ATV212HD30M3X T6A ATV212HD30N4 (2) T5A ATV212WD30N4 T5 ATV212WD30N4C T537/50 – ATV212HD37N4 T7A ATV212WD37N4 T6 ATV212WD37N4C T645/60 – ATV212HD45N4 T7A ATV212WD45N4 T6 ATV212WD45N4C T655/75 – ATV212HD55N4 T8A ATV212WD55N4 T7 ATV212WD55N4C T775/100 – ATV212HD75N4 T8A ATV212WD75N4 T7 ATV212WD75N4C T7(1) Drive with local controls, Run/Stop, Loc/Rem. keys(2) For references ATV212HD22N4 and ATV212HD30N4, please refer to the Schneider Electric catalogue.(3) PC Software is available as a free download from www.schneider-electric.com12345678910Other versions: please consult our Customer Care Centre.4/15


Altivar 3120.18…15 kWSimple industrial machinesHigh performance drives1234Dimensions (in mm)width x height x depthT 1: 72 X 145 X 122 T 6: 107 X 143 X 152T 2: 72 X 145 X 132 T 7: 142 X 184 X 152T 3: 72 X 145 X 132 T 8: 180 X 232 X 172T 4: 72 X 145 X 142 T 9: 245 X 330 X 192T 5: 105 X 143 X 132Type of drive Single-phase 240 V Three-phase 240 V Three-phase 500V Three-phase 600VSupply voltage with integrated EMC filters without EMC filter with integrated EMC filters without EMC filterDegree of protectionIP20Drive Output frequency 0.5…500 HzType of control Asynchronous motor Standard (voltage / frequency) - Performance (sensorless flux vector control)Energy saving ratioTransient overtorque170 ... 200% of the nominal motor torqueSpeed range 1 to 50Functions Number of functions 50Number of preset speeds 16Number of I/O Analog inputs 3Logic inputs 6Analog outputs 1Logic outputs –Relay outputs 2DialogueIntegrated 4-digit display, remote terminals (IP54 or IP65), Altivar 61/71 remote graphic display terminal567Communication Integrated Modbus and CANopenAs an optionCANopen Daisy chain, Modbus TCP, DeviceNet, PROFIBUS DP, FipioReduction of current harmonicsEMC filter Integrated C2 EMC External as an option Integrated C2(1) or C3 EMC External as an optionAs an option C1 EMC – – –Motor power kW/HP 0.18/0.25 ATV312H018M2 T3 ATV312H018M3 T1 – –0.37/0.5 ATV312H037M2 T3 ATV312H037M3 T1 ATV312H037N4 T5 –0.55/0.75 ATV312H055M2 T4 ATV312H055M3 T2 ATV312H055N4 T5 –0.75/1 ATV312H075M2 T4 ATV312H075M3 T2 ATV312H075N4 T6 ATV312H075S6 T61.1/1.5 ATV312HU11M2 T6 ATV312HU11M3 T5 ATV312HU11N4 T6 –1.5/2 ATV312HU15M2 T6 ATV312HU15M3 T5 ATV312HU15N4 T6 ATV312HU15S6 T62.2/3 ATV312HU22M2 (2) T7 ATV312HU22M3 T6 ATV312HU22N4 T7 ATV312HU22S6 T73/- – ATV312HU30M3 T7 ATV312HU30N4 T7 –4/5 – ATV312HU40M3 T7 ATV312HU40N4 T7 ATV312HU40S6 T75.5/7.5 – ATV312HU55M3 T8 ATV312HU55N4 T8 ATV312HU55S6 T87.5/10 – ATV312HU75M3 T8 ATV312HU75N4 T8 ATV312HU75S6 T811/15 – ATV312HD11M3 T9 ATV312HD11N4 T9 ATV312HD11S6 T915/20 – ATV312HD15M3 T9 ATV312HD15N4 T9 ATV312HD15S6 T9(1) C2 up to 4 kW(2) Supplied with integrated C3 EMC filter89104/16Other versions: please consult our Customer Care Centre.


Altivar 31C0.18…15 kWSimple machinesEnclosed IP55 drivesDimensions (in mm)width x height x depthSize 1: 210 x 240 x 163 / Size 2: 215 x 297 x 192Size 3: 230 x 340 x 208 / Size 4: 320 x 512 x 282Size 5: 440 x 625 x 282Supply voltage Single-phase 200…240 V Three-phase 380…500 VDegree of protectionIP55Description Enclosure equipped with an Altivar 31 drive with external heatsink. Removable covers for adding 1switch-disconnector or 1 circuit-breaker, 3 buttons and/or LEDs, 1 potentiometerMotor power kW/HP 0.18/0.25 ATV31C018M2 Size 1 –0.37/0.5 ATV31C037M2 Size 1 ATV31C037N4 Size 20.55/0.75 ATV31C055M2 Size 1 ATV31C055N4 Size 20.75/1 ATV31C075M2 Size 1 ATV31C075N4 Size 21.1/1.5 ATV31CU11M2 Size 2 ATV31CU11N4 Size 21.5/2 ATV31CU15M2 Size 2 ATV31CU15N4 Size 22.2/3 ATV31CU22M2 Size 3 ATV31CU22N4 Size 33/– – ATV31CU30N4 Size 34/5 – ATV31CU40N4 Size 35.5/7.5 – ATV31CU55N4 (1) Size 47.5/10 – ATV31CU75N4 (1) Size 411/15 – ATV31CD11N4 (1) Size 515/20 – ATV31CD15N4 (1) Size 5(1) Drive in metal enclosure without cover.12345678910Other versions: please consult our Customer Care Centre.4/17


Altivar 320.18…15 kWComplex machinesCompact drives12345678Dimensions (in mm) width x height x depthT1: 45 x 317 x 245T2: 60 x 317 x 245T4: 150 x 308 x 232 (EMC plate installed)T4: 150 x 232 x 232 (EMC plate not installed)T5: 180 x 404 x 232 (EMC plate installed)T5: 180 x 330 x 232 (EMC plate not installed)Type of drive Single-phase Three-phase240 V with integrated EMC filter 500 V with integrated EMC filterDegree of protectionIP20Drive Output frequency 0.1…599 HzType of control Asynchronous motor Standard (voltage/frequency)Performance (sensorless fl ux vector control)Pump/fan (Kn² quadratic ratio)Energy saving ratioSynchronous motor Profile for open loop synchronous motorTransient overtorque170...200% of the nominal motor torqueSpeed range 1 to 50Functions Number of functions 150Number of I/O Analog inputs 3 - Response time : 3ms, resolution 10 bitsLogic inputs6 - Response time : 8 ms, configurable in PTC and IN pwmAnalog outputs 1 - Updating time : 2 msLogic outputs1 - Sampling time : 2 ms, configurable as voltage (0-10 V) or current (0-20 mA)Relay outputs 2Dialogue4-digit display, remote display terminal (IP54 or IP55), remote graphic display terminal, SoMove setupsoftware and SoMove Mobile application for mobile phone.Communication Integrated Modbus and CANopen - Bluetooth® linkAs an optionDeviceNet, PROFIBUS DP V1, EtherNet/IP, Modbus TCP, EtherCatReduction of current harmonicsEMC filter Integrated C2 EMCAs an optionC1 EMCMotor power kW HP0.18 1/4 ATV32H018M2 T1 –0.37 1/2 ATV32H037M2 T1 ATV32H037N4 T10.55 3/4 ATV32H055M2 T1 ATV32H055N4 T10.75 1 ATV32H075M2 T1 ATV32H075N4 T11.1 11/2 ATV32HU11M2 T2 ATV32HU11N4 T11.5 2 ATV32HU15M2 T2 ATV32HU15N4 T12.2 3 ATV32HU22M2 T2 ATV32HU22N4 T23 - – ATV32HU30N4 T24 5 – ATV32HU40N4 T25.5 71/2 – ATV32HU55N4 T47.5 10 – ATV32HU75N4 T411 15 – ATV32HD11N4 T515 20 – ATV32HD15N4 T59104/18Other versions: please consult our Customer Care Centre.


Altivar 610.37…800 kWPumping and ventilation machinesDrives for industry and infrastructureDimensions (in mm)width x height x depthT2 : 130 x 230 x 175 T3 : 155 x 260 x 187T4 : 175 x 295 x 187 T5A : 210 x 295 x 213T5B : 230 x 400 x 213 T6 : 240 x 420 x 236T7A : 240 x 550 x 266 T7B : 320 x 550 x 266T8 : 320 x 630 x 290 T9 : 320 x 920 x 377T10 : 360 x 1022 x 377 T11 : 340 x 1190 x 377T12 : 440 x 1190 x 377 T13 : 595 x 1190 x 377T14 : 890 x 1390 x 377 T15 : 1120 x 1390 x 377Type of driveSupply voltageSingle-phase200…240 VThree-phase200…240 VThree-phase380…480 VDegree of protectionIP20 for unprotected drives and IP41 on the upper partDrive Output frequency 0.1…599 Hz up to 37 kW; 0.1…500 Hz from 45 to 800 kWType of control Asynchronous motor Kn 2 quadratic ratio, flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), energy saving ratioSynchronous motor Vector control without speed feedbackTransient overtorque120…130% of the nominal drive current for 60 secondsSpeed range1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4/Logic inputs 6…20Analog outputs 1…3/Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (3)Communication Integrated Modbus and CANopenAs an optionHVAC protocols: LonWorks, BACnet, METASYS N2, APOGEE FLN P1Industrial protocols: Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, EtherCAT,DeviceNet, PROFIBUS DP V0 and V1, INTERBUS, CC-LinkCards (available as an option)Multi-pump cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsDC choke integrated or supplied with the drive or AFE Altivar (Active Front End)EMC filter Integrated C2 EMC C2 EMC up to 7.5 kW C2 EMC up to 4 kWC3 EMC from 5.5 to 630 kWAs an option C1 EMC C1 EMC C1 EMCfrom 0.75 to 630 kWMotor power kW/HP 0.37/0.5 ATV61H075M3 T2 – –0.75/1 ATV61HU15M3 T2 ATV61H075M3 T2 ATV61H075N4 T21.5/2 ATV61HU22M3 T3 ATV61HU15M3 T2 ATV61HU15N4 T22.2/3 ATV61HU30M3 T3 ATV61HU22M3 T3 ATV61HU22N4 T23/– ATV61HU40M3 (1) T3 ATV61HU30M3 T3 ATV61HU30N4 T34/5 ATV61HU55M3 (1) T4 ATV61HU40M3 T3 ATV61HU40N4 T35.5/7.5 ATV61HU75M3 (1) T5A ATV61HU55M3 T4 ATV61HU55N4 T47.5/10 – ATV61HU75M3 T5A ATV61HU75N4 T411/15 – ATV61HD11M3X(2) T5B ATV61HD11N4 T5A15/20 – ATV61HD15M3X(2) T5B ATV61HD15N4 T5B18.5/25 – ATV61HD18M3X(2) T6 ATV61HD18N4 T5A22/30 – ATV61HD22M3X(2) T6 ATV61HD22N4 T630/40 – ATV61HD30M3X(2) T7B ATV61HD30N4 T7A37/50 – ATV61HD37M3X(2) T7B ATV61HD37N4 T7A45/60 – ATV61HD45M3X(2) T7B ATV61HD45N4 T855/75 – ATV61HD55M3X(2) T9 ATV61HD55N4 T875/100 – ATV61HD75M3X(2) T9 ATV61HD75N4 T890/125 – ATV61HD90M3X(2) T10 ATV61HD90N4 T9110/150 – – ATV61HC11N4 T9132/200 – – ATV61HC13N4 T10160/250 – – ATV61HC16N4 T11220/350 – – ATV61HC22N4 T12250/400 – – ATV61HC25N4 T13315/500 – – ATV61HC31N4 T13400/600 – – ATV61HC40N4 T14500/700 – – ATV61HC50N4 T14630/900 – – ATV61HC63N4 T15(1) Must be used with a line choke, refer to the Schneider Electric catalogue.(2) Drive supplied without EMC fi lter(3) SoMove setup software : available from 2011. Altivar 61 is also supported by Powersuite software workshop.12345678910For all other variants, please refer to the Schneider Electric catalogue.Other versions: please consult our Customer Care Centre.4/19


Altivar 610.37…800 kWPumping and ventilation machinesDrives for industry and infrastructure123456789Dimensions (in mm)T6 : 240 x 420 x 236T8 : 320 x 630 x 290T11 : 340 x 1190 x 377T13 : 595 x 1190 x 377T15 : 1120 x 1390 x 377width x height x depthType of driveSupply voltageThree-phase500...690 VDegree of protectionIP20 and IP41 on the upper partDrive Output frequency 0.1…599 Hz up to 37 kW; 0.1…500 Hz from 45 to 800 kWType of control Asynchronous motor Kn 2 quadratic ratio, flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), energy saving ratioSynchronous motor Vector control without speed feedbackTransient overtorque120…130% of the nominal drive current for 60 secondsSpeed range1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4/Logic inputs 6…20Analog outputs 1…3/Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (1)Communication Integrated Modbus and CANopenAs an optionHVAC protocols: LonWorks, BACnet, METASYS N2, APOGEE FLN P1Industrial protocols: Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, EtherCAT,DeviceNet, PROFIBUS DP V0 et V1, INTERBUS, CC-LinkCards (available as an option)Multi-pump cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsDC choke integrated or supplied with the product or AFE Altivar (Active Front End)EMC filter Integrated C3 EMCMotor power kW/HP 500 V 575 V 690 VkW HP kW2.2 3 3 ATV61HU30Y T63 – 4 ATV61HU40Y T64 5 5.5 ATV61HU55Y T65.5 7.5 7.5 ATV61HU75Y T67.5 10 11 ATV61HD11Y T611 15 15 ATV61HD15Y T615 20 18.5 ATV61HD18Y T618.5 25 22 ATV61HD22Y T622 30 30 ATV61HD30Y T630 40 37 ATV61HD37Y T837 50 45 ATV61HD45Y T845 60 55 ATV61HD55Y T855 75 75 ATV61HD75Y T875 100 90 ATV61HD90Y T890 125 110 ATV61HC11Y T11110 150 132 ATV61HC13Y T11132 – 160 ATV61HC16Y T11160 200 200 ATV61HC20Y T11200 250 250 ATV61HC25Y T13250 350 315 ATV61HC31Y T13315 450 400 ATV61HC40Y T13400 550 500 ATV61HC50Y T15500 700 630 ATV61HC63Y T15630 800 800 ATV61HC80Y T15(1) SoMove setup software : available from 2011. Altivar 61 is also supported by Powersuite software workshop.For all other variants, please refer to the Schneider Electric catalogue.104/20Other versions: please consult our Customer Care Centre.


Altivar 610.75…90 kWPumping and ventilation machinesIP54 drivesDimensions (in mm)width x height x depthATV61W…TA2 : 235 x 490 x 272 TD : 310 x 665 x 315TA3 : 235 x 490 x 286 TE : 284 x 720 x 315TB : 255 x 525 x 286 TF : 284 x 880 x 343TC : 290 x 560 x 315 TG : 362 x 1000 x 364Type of driveThree-phase 380…480 V1Degree of protectionType 12 (1) / IP54Drive Output frequency 0.1…599 Hz up to 37 kW; 0.1…500 Hz from 45 to 800 kWType of control Asynchronous motor Kn 2 quadratic ratio, flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), energy saving ratioSynchronous motor Vector control without speed feedbackTransient overtorque120…130% of the nominal drive current for 60 secondsSpeed range1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4/Logic inputs 6…20Analog outputs 1…3/Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (2)Communication Integrated Modbus and CANopenAs an optionHVAC protocols: LonWorks, BACnet, METASYS N2, APOGEE FLN P1Industrial protocols: Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, EtherCAT,DeviceNet, PROFIBUS DP V0 and V1, INTERBUS, CC-LinkCards (available as an option)Multi-pump cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsIntegrated DC chokeEMC filter Integrated C2 EMCAs an option – –Motor power kW/HP 0.75/1 ATV61W075N4 TA2 ATV61E5075N4 TA21.5/2 ATV61WU15N4 TA2 ATV61E5U15N4 TA22.2/3 ATV61WU22N4 TA2 ATV61E5U22N4 TA23/– ATV61WU30N4 TA3 ATV61E5U30N4 TA34/5 ATV61WU40N4 TA3 ATV61E5U40N4 TA35.5/7.5 ATV61WU55N4 TB ATV61E5U55N4 TB7.5/10 ATV61WU75N4 TB ATV61E5U75N4 TB11/15 ATV61WD11N4 TC ATV61E5D11N4 TC15/20 ATV61WD15N4 TD ATV61E5D15N4 TD18.5/25 ATV61WD18N4 TD ATV61E5D18N4 TD22/30 ATV61WD22N4 TE ATV61E5D22N4 TE30/40 ATV61WD30N4 TF ATV61E5D30N4 TF37/50 ATV61WD37N4 TF ATV61E5D37N4 TF45/60 ATV61WD45N4 TG ATV61E5D45N4 TG55/75 ATV61WD55N4 TG ATV61E5D55N4 TG75/100 ATV61WD75N4 TG ATV61E5D75N4 TG90/125 ATV61WD90N4 TG ATV61E5D90N4 TGDrive with integrated C1 fi lter: add the letter C at the end of the reference For example, ATV61W075N4 becomes ATV61W075N4CFor other variants, please refer to the Schneider Electric catalogue.(1) For ATV61W... range only.(2) SoMove setup software : available from 2011. Altivar 61 is also supported by Powersuite software workshop.2345678910Other versions: please consult our Customer Care Centre.4/21


Altivar 610.37…800 kWPumping and ventilation machinesIP54 Altivar 61 kit with preassembled enclosure1DriveKit234ATV61HC11N4ATV61HC13N4ATV61HC16N4ATV61HC22N4ATV61HC25N4ATV61HC31N4ATV61HC25N4ATV61HC31N4ATV61HC40N4ATV61HC50N4ATV61HC63N4VW3A7102 braking unitAdditional empty enclosure (600 mm)Additional empty enclosure (800 mm)VW3A9541VW3A9542VW3A9543VW3A9544VW3A9545VW3A9546VW3A9547VW3A9548VW3A9549VW3A9550VW3A955156789104/22Other versions: please consult our Customer Care Centre.


Altivar 61Q110…800 kWPumping and ventilation machinesWater-cooled drives for harsh environmentsDimensions (in mm)T11 : 330 x 950 x 377T13 : 585 x 950 x 377T15 : 1110 x 1150 x 377width x height x depthType of driveSupply voltageThree-phase380...480 VThree-phase500...690 VDegree of protectionSideways and front IP31 - Top IP20 - Bottom IP00Drive Output frequency 0.1...500HzType of control Asynchronous motor Kn 2 quadratic ratio, flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), energy saving ratioSynchronous motor Vector control without speed feedbackTransient overtorque120…130% of the nominal drive current for 60 secondsSpeed range1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4/Logic inputs 6…20Analog outputs 1…3/Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (2)Communication Integrated Modbus and CANopenAs an optionHVAC protocols: LonWorks, BACnet, METASYS N2, APOGEE FLN P1Industrial protocols: Modbus TCP, Modbus/Uni-Telway, Fipio, Modbus Plus, Profbus DP,Profbus DP V1, DeviceNet, EthernetIP, CC-Link, INTERBUSCards (available as an option)Multi-pump cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsOptional AC choke, Altivar AFE (Active Front End)EMC filter Integrated C3 EMCAs an optionC1 EMCMotor power kW/HP 110/150 ATV61QC11N4 T11 –132/200 ATV61QC13N4 T11 –160/250 ATV61QC16N4 T11 –200/300 ATV61QC20N4 T13 –250/400 ATV61QC25N4 T13 –315/500 ATV61QC31N4 T13 –400/600 ATV61QC40N4 T15 –500/700 ATV61QC50N4 T15 –630/900 ATV61QC63N4 T15 –500 V 575 V 690 VKW HP KW110 150 132 – ATV61QC13Y T11132 – 160 – ATV61QC16Y T11160 200 200 – ATV61QC20Y T11200 250 250 – ATV61QC25Y T13250 350 315 – ATV61QC31Y T13315 450 400 – ATV61QC40Y T13400 550 500 – ATV61QC50Y T15500 700 630 – ATV61QC63Y T15630 800 800 – ATV61QC80Y T15(1) SoMove setup software : available during 2011. Altivar 61 also works with the PowerSuite software workshop.12345678910Other versions: please consult our Customer Care Centre.4/23


Altivar 61 Plus90…2400 kWPumping and ventilation machinesSolutions in IP23 and IP54 ready-assembled enclosures123456Dimensions (in mm)ATV61EXC2C…E1 : 616 x 2159 x 659E2 : 816 x 2159 x 659E3 : 1016 x 2159 x 659E4 : 1220 x 2159 x 659Enclosure typeswidth x height x depthThree-phase 380…480 V - 500 V - 690 V(1)Degree of protectionIP23, IP54Drive Output frequency 0.1…599 Hz up to 37 kW; 0.1…500 Hz from 45…2400 kWType of control Asynchronous motor Kn 2 quadratic ratio, flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), energy saving ratioSynchronous motor Vector control without speed feedbackTransient overtorque120…130% of the nominal drive current for 60 secondsSpeed range1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4/Logic inputs 6…20Analog outputs 1…3/Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (2)Communication Integrated Modbus and CANopenAs an optionHVAC protocols: LonWorks, BACnet, METASYS N2, APOGEE FLN P1Industrial protocols: Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, EtherCAT, DeviceNet,PROFIBUS DP V0 and V1, INTERBUS, CC-Link.Cards (available as an option)Multi-pump cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsDC choke or Integrated AC choke, variant 12 pulse, AFE Altivar (Active Front End)EMC filter Integrated C3 EMCEquipmentA wide range of options listed in the catalogue provides add-ons for the standard offer as required.As well as the options listed in the catalogue, it is possible to customise the equipment. Just contact ourteams of experts directly.- Water cooling solution- Integration of specific options78910IP23Three-phase380…415 VThree-phase500 VThree-phase690 VkW/HP Dimensions kW Dimensions kW Dimensions– 90 ATV61 EXC2D90N E1 –110/150 ATV61EXC2C11N4 E1 110 ATV61 EXC2C11N E1 110 ATV61 EXC2C11Y E1132/200 ATV61EXC2C13N4 E1 132 ATV61 EXC2C13N E1 132 ATV61 EXC2C13Y E1160/250 ATV61EXC2C16N4 E1 160 ATV61 EXC2C16N E1 160 ATV61 EXC2C16Y E1220/350 ATV61EXC2C22N4 E1 200 ATV61 EXC2C20N E2 200 ATV61 EXC2C20Y E1250/400 ATV61EXC2C25N4 E2 250 ATV61 EXC2C25N E2 250 ATV61 EXC2C25Y E2315/500 ATV61EXC2C31N4 E2 315 ATV61 EXC2C31N E2 315 ATV61 EXC2C31Y E2400/600 ATV61EXC2C40N4 E3 400 ATV61 EXC2C40N E4 400 ATV61 EXC2C40Y E2500/700 ATV61EXC2C50N4 E3 500 ATV61 EXC2C50N E4 500 ATV61 EXC2C50Y E4630/900 ATV61EXC2C63N4 E4 630 ATV61 EXC2C63N E4 630 ATV61 EXC2C63Y E4800 ATV61 EXC2C80Y E4(1) The Altivar 61 range in ready-assembled enclosure consists of: an ATV61H… drive, a switch and fast-acting fuses, an IP65 remote mounting kit for graphic display terminal(2) SoMove setup software : available from 2011. Altivar 61 is also supported by Powersuite software workshop.IP23 offer available up to 2400 kW. For ratings above 800 kW, please consult your Regional Sales Offi ce.4/24Other versions: please consult our Customer Care Centre.


Altivar 61 Plus90…2400 kWPumping and ventilation machinesSolutions in IP23 and IP54 ready-assembled enclosuresDimensions (in mm) width x height x depthATV61EX…E5 : 616 x 2264 x 659 E9 : 616 x 2359 x 659E6 : 816 x 2264 x 659 E10 : 816 x 2359 x 659E7 : 1016 x 2264 x 659 E11 : 608 x 2359 x 659E8 : 1216 x 2264 x 659 E12 : 808 x 2359 x 6590E13 : 1008 x 2359 x 659E14 : 1208 x 2359 x 659IP54 (1)Three-phase380…415 VThree-phase500 VThree-phase690 VCompact floor-standing enclosure kW/HP Dimensions kW Dimensions kW Dimensions– 90 ATV61EXC5D90N E5 –110/150 ATV61EXC5C11N4 E5 110 ATV61EXC5C11N E5 110 ATV61EXC5C11Y E5132/200 ATV61EXC5C1 3N4 E5 132 ATV61EXC5C13N E5 132 ATV61EXC5C13Y E5160/250 ATV61EXC5C16N4 E5 160 ATV61EXC5C16N E5 160 ATV61EXC5C16Y E5220/350 ATV61EXC5C22N4 E5 200 ATV61EXC5C20N E6 200 ATV61EXC5C20Y E5250/400 ATV61EXC5C25N4 E6 250 ATV61EXC5C25N E6 250 ATV61EXC5C25Y E6315/500 ATV61EXC5C31N4 E6 315 ATV61EXC5C31N E6 315 ATV61EXC5C31Y E6400/600 ATV61EXC5C40N4 E7 400 ATV61EXC5C40N E8 400 ATV61EXC5C40Y E6500/700 ATV61EXC5C50N4 E7 500 ATV61EXC5C50N E8 500 ATV61EXC5C50Y E8630/900 ATV61EXC5C63N4 E8 630 ATV61EXC5C63N E8 630 ATV61EXC5C63Y E8800 ATV61EXC5C80Y E8(1) The IP54 offer is available for power ratings up to 800 kW. For higher power ratings up to 2400 kW, consult your customer care centre.12345IP54 (2)Three-phase380…415 VThree-phase500 VThree-phase690 VSeparate air flow kW/HP Dimensions kW Dimensions kW Dimensions– 90 ATV61E<strong>XS</strong>5D90N E11 –110/150 ATV61E<strong>XS</strong>5C11N4 E9 110 ATV61E<strong>XS</strong>5C11N E11 110 ATV61E<strong>XS</strong>5C11Y E11132/200 ATV61E<strong>XS</strong>5C13N4 E9 132 ATV61E<strong>XS</strong>5C13N E11 132 ATV61E<strong>XS</strong>5C13Y E11160/250 ATV61E<strong>XS</strong>5C16N4 E9 160 ATV61E<strong>XS</strong>5C16N E11 160 ATV61E<strong>XS</strong>5C16Y E11220/350 ATV61E<strong>XS</strong>5C22N4 E9 200 ATV61E<strong>XS</strong>5C20N E12 200 ATV61E<strong>XS</strong>5C20Y E11250/400 ATV61E<strong>XS</strong>5C25N4 E10 250 ATV61E<strong>XS</strong>5C25N E12 250 ATV61E<strong>XS</strong>5C25Y E12315/500 ATV61E<strong>XS</strong>5C31N4 E10 315 ATV61E<strong>XS</strong>5C31N E12 315 ATV61E<strong>XS</strong>5C31Y E12400/600 ATV61E<strong>XS</strong>5C40N4 E13 400 ATV61E<strong>XS</strong>5C40N E14 400 ATV61E<strong>XS</strong>5C40Y E12500/700 ATV61E<strong>XS</strong>5C50N4 E13 500 ATV61E<strong>XS</strong>5C50N E14 500 ATV61E<strong>XS</strong>5C50Y E14630/900 ATV61E<strong>XS</strong>5C63N4 E14 630 ATV61E<strong>XS</strong>5C63N E14 630 ATV61E<strong>XS</strong>5C63Y E14800 ATV61E<strong>XS</strong>5C80Y E14(2) The IP54 offer with separate air flow is available for power ratings upt o 800 kW. For higher power ratings up to 2400 kW, consult your customer care centre.678910Other versions: please consult our Customer Care Centre.4/25


Altivar 610.37…2400 kWPumping and ventilation machinesI/O extension and specific cards1234Type of cardI/O extensionLogicExtendedDescription1 relay logic output (“C/O” contact)4 x 24 VDC positive or negative logic inputs1 x 0…20 mA differential current analog input1 software-configurable voltage (0…10 VDC) or2 x 24 VDC open collector positive or negative logic current (0…20 mA) analog inputoutputs1 input for PTC probes2 software-configurable voltage (±10V, 0…10 VDC)or current (0…20 mA) analog inputs1 relay logic output (“C/O” contact)4 x 24 VDC positive or negative logic inputs2 x 24 VDC open collector positive or negative logicoutputs1 input for PTC probes1 frequency control inputReference VW3A3201 VW3A3202"Controller Inside" programmable card56Type of cardProgrammable “Controller Inside”7DescriptionReference10 logic inputs, 2 of which can be used for 2 counters or 4 of which can be used for 2 incremental encoders2 analog inputs, 6 logic outputs, 2 analog outputs, a master port for the CANopen bus, a PC port forprogramming with the PS 1131 software workshop.VW3A35018Multi-pump cards9Type of cardMulti-pump10DescriptionReferenceDescriptionReferenceThe pump switching card ensures compatibility ofapplications developed on the Altivar 38.The VWA3503 “Water Solution” card can be usedto support all multi-pump applications.This card is specific to pump switching.It ensures optimum flow for an impeccable quality of service.Its algorithm both saves energy and prolongs equipment service life.VW3A3502This card offers all the functions needed to manage a pumping, booster, irrigation station, etc with theoperational safety of a control and monitoring system.VW3A35034/26Other versions: please consult our Customer Care Centre.


Accessories and optionsBraking resistorsThe network braking unit can be used to restore the following to theline supply:p The energy from the motorp The energy from the motors controlled by several drives connectedon the same DC busType of driveThree-phaseSupply voltage 200…240 V 50/60 Hz 380…480 V 50/60 HzATV61H075M3 VW3A7701 –ATV61HU15M3, HU22M3 VW3A7702 –ATV61HU30M3, HU40M3 VW3A7703 –ATV61HU55M3, HU75M3 VW3A7704 –ATV61HD11M3X VW3A7705 –ATV61HD15M3X VW3A7706 –ATV61HD18M3X, HD22M3X VW3A7707 –ATV61HD30M3X VW3A7708 –ATV61HD37M3X, HD45M3X VW3A7709 –ATV61HD55M3X, HD75M3X VW3A7713 –ATV61HD90M3X VW3A7714 –ATV61H075N4…HU40N4, ATV61W075N4…WU55N4, – VW3A7701ATV61W075N4C…WU55N4CATV61HU55N4, HU75N4, ATV61WU75N4, WD11N4, – VW3A7702ATV61WU75N4C, WD11N4CATV61HD11N4, HD15N4, ATV61WD15N4, WD18N4, – VW3A7703ATV61WD15N4C, WD18N4CATV61HD18N4…HD30N4, ATV61WD22N4…WD37N4, – VW3A7704ATV61WD22N4C…WD37N4CATV61HD37N4, ATV61WD45N4, WD45N4C – VW3A7705ATV61WD55N4…WD90N4, ATV61WD55N4C…WD90N4C – VW3A7706ATV61HD45N4…HD75N4 – VW3A7707ATV61HD90N4, HC11N4 – VW3A7710ATV61HC13N4, HC16N4, E5C16N4 – VW3A7711ATV61HC22N4 – VW3A7712ATV61HC25N4 – VW3A7715ATV61HC31N4 – VW3A7716ATV61HC40N4, HC50N4, E5C50N4 – VW3A7717ATV61HC63N4 – VW3A7718Other accessories (see references in the Schneider Electric Catalogue)> Resistance braking units (integrated in ATV61 drives up to 220 kW)> Additional EMC input filters> AC line chokes> Optional DC chokes> Passive filters> Sinus filters> Motor chokes> Altivar AFE (Active Front End)> Regenerative network braking unit12345678910Other versions: please consult our Customer Care Centre.4/27


Altivar 710.37…630 kWComplex, high-power machinesHigh performance drives1Dimensions (in mm) width x height x depthT2 : 130 x 230 x 175 T3 : 155 x 260 x 187T4 : 175 x 295 x 187 T5A : 210 x 295 x 213T5B : 230 x 400 x 213 T6 : 240 x 420 x 236T7A : 240 x 550 x 266 T7B : 320 x 550 x 266T8 : 320 x 630 x 290 T9 : 320 x 920 x 377T10 : 360 x 1022 x 377 T11 : 340 x 1190 x 377T12 : 440 x 1190 x 377 T13 : 595 x 1190 x 377T14 : 890 x 1390 x 377 T15 : 1120 x 1390 x 3772345678910Type of drive Single-phase Three-phase Three-phaseSupply voltage 200…240 V (3) 200…240 V (3) 380…480 V (3)Degree of protectionIP20 for unprotected drives and IP41 on the upper partDrive Output frequency 0…599 Hz up to 37 kW - 0…500 Hz from 45…630 kWType of control Asynchronous motor Flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), ENA SystemSynchronous motor Vector control with and without speed feedback (4)Transient overtorque220% of nominal motor torque for 2 seconds, and 170% for 60 secondsSpeed range1…1000 in closed loop mode with encoder feedback, 1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4Logic inputs 6…20Analog outputs 1…3Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (5)Communication Integrated Modbus and CANopenAs an option Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, EtherCAT, DeviceNet, PROFIBUS DP V0 and V1,Cards (available as an option)INTERBUS, CC-Link.Encoder interface cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonics DC choke integrated or supplied with the product or Altivar AFE (Active Front End ).EMC filter Integrated C2 EMC up to 4 kW, C3 EMC from 5,5 to 500 kWAs an optionC1 EMC from 0.75 to 500 kWMotor power kW/HP 0.37/0.5 ATV71H075M3 T2 ATV71H037M3 T2 –0.75/1 ATV71HU15M3 T2 ATV71H075M3 T2 ATV71H075N4 T21.5/2 ATV71HU22M3 T3 ATV71HU15M3 T2 ATV71HU15N4 T22.2/3 ATV71HU30M3 T3 ATV71HU22M3 T3 ATV71HU22N4 T23/– ATV71HU40M3 (1) T3 ATV71HU30M3 T3 ATV71HU30N4 T34/5 ATV71HU55M3 (1) T4 ATV71HU40M3 T3 ATV71HU40N4 T35.5/7.5 ATV71HU75M3 (1) T5A ATV71HU55M3 T4 ATV71HU55N4 T47.5/10 – ATV71HU75M3 T5A ATV71HU75N4 T411/15 – ATV71HD11M3X (2) T5B ATV71HD11N4 T5A15/20 – ATV71HD15M3X (2) T5B ATV71HD15N4 T5B18.5/25 – ATV71HD18M3X (2) T6 ATV71HD18N4 T5B22/30 – ATV71HD22M3X (2) T6 ATV71HD22N4 T630/40 – ATV71HD30M3X (2) T7B ATV71HD30N4 T7A37/50 – ATV71HD37M3X (2) T7B ATV71HD37N4 T7A45/60 – ATV71HD45M3X (2) T7B ATV71HD45N4 T855/75 – ATV71HD55M3X (2) T9 ATV71HD55N4 T875/100 – ATV71HD75M3X (2) T10 ATV71HD75N4 T890/125 – – ATV71HD90N4 T9110/150 – – ATV71HC11N4 T10132/200 – – ATV71HC13N4 T11160/250 – – ATV71HC16N4 T12200/300 – – ATV71HC20N4 T13220/350 – – ATV71HC25N4 T13280/450 – – ATV71HC28N4 T13315/500 – – ATV71HC31N4 T14355/– – – ATV71HC40N4 T14500/700 – – ATV71HC50N4 T15(1) Must be used with a line choke, Refer to the Schneider Electric catalogue.(2) Drive supplied without EMC fi lter.(3) A three-phase 380...480 V range on base plate is available from 0.75 to 11 kW. Please refer to the Schneider Electric catalogue.(4) Vector control with speed feedback for synchronous motors is supported by the S383 variant of the Altivar 71.(5) SoMove setup software : available from 2011. Altivar 71 is also supported by Powersuite software workshop.4/28Other versions: please consult our Customer Care Centre.


Altivar 710.37…630 kWComplex, high-power machinesHigh performance drivesDimensions (in mm) width x height x depthT2 : 130 x 230 x 175 T3 : 155 x 260 x 187T4 : 175 x 295 x 187 T5A : 210 x 295 x 213T5B : 230 x 400 x 213 T6 : 240 x 420 x 236T7A : 240 x 550 x 266 T7B : 320 x 550 x 266T8 : 320 x 630 x 290 T9 : 320 x 920 x 377T10 : 360 x 1022 x 377 T11 : 340 x 1190 x 377T12 : 440 x 1190 x 377 T13 : 595 x 1190 x 377T14 : 890 x 1390 x 377 T15 : 1120 x 1390 x 377Type of driveThree-phaseSupply voltage500... 690 VDegree of protectionIP20 for unprotected drives and IP41 on the upper partDrive Output frequency 0…599 Hz up to 37 kW - 0…500 Hz from 45…630 kWType of control Asynchronous motor Flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), ENA SystemSynchronous motor Vector control with and without speed feedback (1)Transient overtorque220% of nominal motor torque for 2 seconds, and 170% for 60 secondsSpeed range1…1000 in closed loop mode with encoder feedback, 1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4Logic inputs 6…20Analog outputs 1…3Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (2)Communication Integrated Modbus and CANopenAs an option Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, EtherCAT, DeviceNet, PROFIBUS DP V0 and V1,Cards (available as an option)INTERBUS, CC-Link.Encoder interface cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsDC choke integrated or DC choke optional or AFE Altivar (Active Front End)EMC filter Integrated C3 EMCMotor power kW/HP 500 V 575 V 690 VkW HP kW1.5 2 2.2 ATV71HU22Y T62.2 3 3 ATV71HU30Y T63 – 4 ATV71HU40Y T64 5 5.5 ATV71HU55Y T65.5 7.5 7.5 ATV71HU75Y T67.5 10 11 ATV71HD11Y T611 15 15 ATV71HD15Y T615 20 18.5 ATV71HD18Y T618.5 25 22 ATV71HD22Y T622 30 30 ATV71HD30Y T630 40 37 ATV71HD37Y T837 50 45 ATV71HD45Y T845 60 55 ATV71HD55Y T855 75 75 ATV71HD75Y T875 100 90 ATV71HD90Y T890 125 110 ATV71HC11Y T11110 150 132 ATV71HC13Y T11132 – 160 ATV71HC16Y T11160 200 200 ATV71HC20Y T13200 250 250 ATV71HC25Y T13250 350 315 ATV71HC31Y T13315 450 400 ATV71HC40Y T15400 550 500 ATV71HC50Y T15500 700 630 ATV71HC63Y T15(1) Vector control with speed feedback for synchronous motors is supported by the S383 variant of the Altivar 71.(2) SoMove setup software : available from 2011. Altivar 71 is also supported by Powersuite software workshop..For all other variants, please refer to the Schneider Electric catalogue.12345678910Other versions: please consult our Customer Care Centre.4/29


Altivar 710.75…75 kWComplex, high-power machinesIP54 drives12345678Dimensions (in mm) width x height x depthATV71W…, ATV71E5…up to 75 kWTA2 : 235 x 490 x 272 TD : 310 x 665 x 315TA3 : 235 x 490 x 286 TE : 284 x 720 x 315TB : 255 x 525 x 286 TF : 284 x 880 x 343TC : 290 x 560 x 315 TG : 362 x 1000 x 364Type of driveThree-phase 380…480 VWith switchDegree of protectionUL Type 12 (1) / IP54Drive Output frequency 0…599 Hz up to 37 kW - 0…500 Hz from 45…75 kWType of control Asynchronous motor Flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), ENA SystemSynchronous motor Vector control without speed feedbackTransient overtorque220% of nominal motor torque for 2 seconds, and 170% for 60 secondsSpeed range1…1000 in closed loop mode with encoder feedback, 1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4Logic inputs 6…20Analog outputs 1…3Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (2)Communication Integrated Modbus and CANopenAs an option Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, EtherCAT, DeviceNet, PROFIBUS DP V0 et V1,INTERBUS, CC-Link.Cards (available as an option)Encoder interface cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsOptional chokes and passive fi ltersEMC filter Integrated C2 EMCAs an optionExternal C1 EMCMotor power kW/HP 0.75/1 ATV71W075N4 TA2 ATV71E5075N4 TA21.5/2 ATV71WU15N4 TA2 ATV71E5U15N4 TA22.2/3 ATV71WU22N4 TA2 ATV71E5U22N4 TA23/– ATV71WU30N4 TA3 ATV71E5U30N4 TA34/5 ATV71WU40N4 TA3 ATV71E5U40N4 TA35.5/7.5 ATV71WU55N4 TB ATV71E5U55N4 TB7.5/10 ATV71WU75N4 TB ATV71E5U75N4 TB11/15 ATV71WD11N4 TC ATV71E5D11N4 TC15/20 ATV71WD15N4 TD ATV71E5D15N4 TD18.5/25 ATV71WD18N4 TD ATV71E5D18N4 TD22/30 ATV71WD22N4 TD ATV71E5D22N4 TD30/40 ATV71WD30N4 TF ATV71E5D30N4 TF37/50 ATV71WD37N4 TF ATV71E5D37N4 TF45/60 ATV71WD45N4 TG ATV71E5D45N4 TG55/75 ATV71WD55N4 TG ATV71E5D55N4 TG75/100 ATV71WD75N4 TG ATV71E5D75N4 TG(1) For ATV71W... range only.(2) SoMove setup software : available from 2011. Altivar 71 is also supported by Powersuite software workshop.9104/30Other versions: please consult our Customer Care Centre.


Altivar 7190…500 kWComplex, high-power machinesIP54 Altivar 71 kit with preassembled enclosure1DriveKitATV71HD90N4VW3A9541ATV71HC11N4VW3A9542ATV71HC13N4VW3A9543ATV71HC16N4VW3A9544ATV71HC20N4VW3A9545ATV71HC25N4ATV71HC28N4ATV71HC20N4 With VW3A7101 braking unit VW3A9546ATV71HC25N4With VW3A7101 braking unitATV71HC28N4With VW3A7101 braking unitATV71HC31N4 Without braking unit VW3A9547ATV71HC40N4ATV71HC50N4VW3A9548VW3A7102 braking unitVW3A9549Additional empty enclosure (600 mm) VW3A9550Additional empty enclosure (800 mm) VW3A95512345678910Other versions: please consult our Customer Care Centre.4/31


Altivar 71Q90…630 kWComplex, high-power machinesWater-cooled drives for harsh environments123456789Dimensions (in mm)T11 : 330 x 950 x 377T13 : 585 x 950 x 377T15 : 1110 x 1150 x 377width x height x depthType of driveThree-phaseThree-phaseSupply voltageDegree of protection380...480 VSideways and front IP31 - Top IP20 - Bottom IP00500...690 VDrive Output frequency 0.1...500HzType of control Asynchronous motor Flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), ENA SystemSynchronous motor Vector control without speed feedbackTransient overtorque220% of nominal motor torque for 2 seconds, and 170% for 60 secondsSpeed range1…1000 in closed loop mode with encoder feedback, 1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4Logic inputs 6…20Analog outputs 1…3Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (1)Communication Integrated Modbus and CANopenAs an optionModbus TCP, Modbus/Uni-Telway, Fipio, Modbus Plus, Profbus DP, Profbus DP V1, DeviceNet,EthernetIP, CC-Link, INTERBUSCards (available as an option)Multi-pump cards, I/O extension cards, “Controller Inside” programmable cardReduction of current harmonicsOptional AC choke, Altivar AFE (Active Front End)EMC filter Integrated C3 EMCAs an optionC1 EMCMotor power kW/HP 90/125 ATV71QD90N4 T11 –110/150 ATV71QC11N4 T11 –132/200 ATV71QC13N4 T11 –160/250 ATV71QC16N4 T13 –200/300 ATV71QC20N4 T13 –250/400 ATV71QC25N4 T13 –315/500 ATV71QC31N4 T15 –400/600 ATV71QC40N4 T15 –500/700 ATV71QC50N4 T15 –500 V 575 V 690 VKW HP KW90 125 110 – ATV71QC11Y T11110 150 132 – ATV71QC13Y T11132 - 160 – ATV71QC16Y T11160 200 200 – ATV71QC20Y T13200 250 250 – ATV71QC25Y T13250 350 315 – ATV71QC31Y T13315 450 400 – ATV71QC40Y T15400 550 500 – ATV71QC50Y T15500 700 630 – ATV71QC63Y T15(1) SoMove setup software : available during 2011. Altivar 71 also works with the PowerSuite software workshop.104/32Other versions: please consult our Customer Care Centre.


Altivar 71 Plus90…2000 kWComplex, high-power machinesSolutions in IP23 and IP54 ready-assembled enclosuresDimensions (in mm) width x height x depthATV71EXC2C…E1 : 616 x 2159 x 659 E3 : 1016 x 2159 x 659E2 : 816 x 2159 x 659 E4 : 1216 x 2159 x 6591Type of driveThree-phase 380…480 V(1)Degree of protectionIP23 et IP54Drive Output frequency 0…500 HzType of control Asynchronous motor Flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), ENA SystemSynchronous motor Vector control without speed feedbackTransient overtorque220% of nominal motor torque for 2 seconds, and 170% for 60 secondsSpeed range1…1000 in closed loop mode with encoder feedback, 1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4Logic inputs 6…20Analog outputs 1…3Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (2)Communication Integrated Modbus and CANopenAs an option Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, EtherCAT, DeviceNet, PROFIBUS DP V0 et V1,INTERBUS, CC-Link.Cards (available as an option)Encoder interface cards, I/O extension cards, “Controller Inside” programmable card,Reduction of current harmonicsDC choke or Integrated AC choke, variant 12 pulse, AFE Altivar (Active Front End)EMC filter Integrated C3 EMCAs an optionExternal C1 EMCEquipmentA wide range of options listed in the catalogue provides add-ons for the standard offer as required.As well as the options listed in the catalogue, it is possible to customise the equipment. Just contact ourteams of experts direct.- Water cooling solution- Integration of specific options23456IP23(1) The Altivar 71 range in ready-assembled enclosure consists of:– An ATV71H… drive– A switch and fast-acting fuses– An IP65 remote mounting kit for graphic display terminal(2) SoMove setup software : available from 2011. Altivar 71 is also supported by Powersuite software workshop.Three-phase380…415 VThree-phase500 VThree-phase690 VkW/HP Dimensions kW Dimensions kW Dimensions90/125 ATV71EXC2D90N4 E1 90 ATV71 EXC2D90N E1 –110/150 ATV71EXC2C11N4 E1 110 ATV71 EXC2C11N E1 110 ATV71 EXC2C11Y E1132/200 ATV71EXC2C13N4 E1 132 ATV71 EXC2C13N E1 132 ATV71 EXC2C13Y E1160/250 ATV71EXC2C16N4 E1 160 ATV71 EXC2C16N E2 160 ATV71 EXC2C16Y E1200/300 ATV71EXC2C20N4 E2 200 ATV71 EXC2C20N E2 200 ATV71 EXC2C20Y E2250/400 ATV71EXC2C25N4 E2 250 ATV71 EXC2C25N E2 250 ATV71 EXC2C25Y E2280/450 ATV71EXC2C28N4 E2 – –315/500 ATV71EXC2C31N4 E3 315 ATV71 EXC2C31N E4 315 ATV71 EXC2C31Y E2400/600 ATV71EXC2C40N4 E3 400 ATV71 EXC2C40N E4 400 ATV71 EXC2C40Y E4500/700 ATV71EXC2C50N4 E4 500 ATV71 EXC2C50N E4 500 ATV71 EXC2C50Y E4IP23 offer available up to 2000 kW. For ratings above 630 kW, please consult your Customer Care Centre.78910Other versions: please consult our Customer Care Centre.4/33


Altivar 71 Plus90…2000 kWComplex, high-power machinesSolutions in IP23 and IP54 ready-assembled enclosures1234Dimensions (in mm) width x height x depthATV71EX…E5 : 616 x 2264 x 659 E9 : 616 x 2359 x 659E6 : 816 x 2264 x 659 E10 : 816 x 2359 x 659E7 : 1016 x 2264 x 659 E11 : 608 x 2359 x 659E8 : 1216 x 2264 x 659 E12 : 808 x 2359 x 6590E13 : 1008 x 2359 x 659E14 : 1208 x 2359 x 659IP54 (1)Three-phase380…415 VThree-phase500 VThree-phase690 VCompact floor-standing enclosure kW/HP Dimensions kW Dimensions kW Dimensions90/125 ATV71EXC5D90N4 E5 90 ATV71EXC5D90N E5 –110/150 ATV71EXC5C11N4 E5 110 ATV71EXC5C11N E5 110 ATV71EXC5C11Y E5132/200 ATV71EXC5C13N4 E5 132 ATV71EXC5C13N E5 132 ATV71EXC5C13Y E5160/250 ATV71EXC5C16N4 E5 160 ATV71EXC5C16N E6 160 ATV71EXC5C16Y E5220/350 ATV71EXC5C20N4 E6 200 ATV71EXC5C20N E6 200 ATV71EXC5C20Y E6250/400 ATV71EXC5C25N4 E6 250 ATV71EXC5C25N E6 250 ATV71EXC5C25Y E6280/450 ATV71EXC5C28N4 E6 – –315/500 ATV71EXC5C31N4 E7 315 ATV71EXC5C31N E8 315 ATV71EXC5C31Y E6400/600 ATV71EXC5C40N4 E7 400 ATV71EXC5C40N E8 400 ATV71EXC5C40Y E8500/700 ATV71EXC5C50N4 E8 500 ATV71EXC5C50N E8 500 ATV71EXC5C50Y E8630 ATV71EXC5C63Y E8(1) The IP54 offer is available for power ratings up to 630 kW. For higher power ratings up to 2000 kW, consult your customer care centre.5678IP54 (2)Three-phase380…415 VThree-phase500 VThree-phase690 VSeparate air flow kW/HP Dimensions kW Dimensions kW Dimensions90/125 ATV71E<strong>XS</strong>5D90N4 E9 90 ATV71E<strong>XS</strong>5D90N E11 –110/150 ATV71E<strong>XS</strong>5C11N4 E9 110 ATV71E<strong>XS</strong>5C11N E11 110 ATV71E<strong>XS</strong>5C11Y E11132/200 ATV71E<strong>XS</strong>5C13N4 E9 132 ATV71E<strong>XS</strong>5C13N E11 132 ATV71E<strong>XS</strong>5C13Y E11160/250 ATV71E<strong>XS</strong>5C16N4 E9 160 ATV71E<strong>XS</strong>5C16N E12 160 ATV71E<strong>XS</strong>5C16Y E11220/350 ATV71E<strong>XS</strong>5C20N4 E10 200 ATV71E<strong>XS</strong>5C20N E12 200 ATV71E<strong>XS</strong>5C20Y E12250/400 ATV71E<strong>XS</strong>5C25N4 E10 250 ATV71E<strong>XS</strong>5C25N E12 250 ATV71E<strong>XS</strong>5C25Y E12280/450 ATV71E<strong>XS</strong>5C28N4 E10 – –315/500 ATV71E<strong>XS</strong>5C31N4 E13 315 ATV71E<strong>XS</strong>5C31N E14 315 ATV71E<strong>XS</strong>5C31Y E12400/600 ATV71E<strong>XS</strong>5C40N4 E13 400 ATV71E<strong>XS</strong>5C40N E14 400 ATV71E<strong>XS</strong>5C40Y E14500/700 ATV71E<strong>XS</strong>5C50N4 E14 500 ATV71E<strong>XS</strong>5C50N E14 500 ATV71E<strong>XS</strong>5C50Y E14630 ATV71E<strong>XS</strong>5C63Y E14(2) The IP54 offer with separate air flow is available for power ratings up to 630 kW. For higher power ratings up to 2000 kW, consult your customer care centre.9104/34Other versions: please consult our Customer Care Centre.


Altivar LIFT4…22 kWComplex, high-power machinesDrives for liftsDimensions (in mm) width x height x depthwithout remote graphic terminalT4 : 175 x 295 x 161 T6 : 240 x 420 x 210T5A : 210 x 295 x 187 T7 : 240 x 550 x 230T5B : 230 x 400 x 1871Type of driveThree-phaseThree-phaseSupply voltage200...240 V380...480 VDegree of protectionIP20 for unprotected drives and IP41 on the upper partDrive Output frequency 0...599 HzType of control Asynchronous motor Flux vector control with or without sensor, voltage/frequency ratioSynchronous motor Vector control with and without speed feedbackTransient overtorque220% of nominal motor torque for 2 seconds, and 170% for 60 secondsSpeed range1…1000 in closed loop mode with encoder feedback, 1…100 in open loop modeFunctions Number of functions > 150Number of preset speeds 16Number of I/O Analog inputs 2…4Logic inputs 6…20Analog outputs 1…3Logic outputs 0…8Relay outputs 2…4Safety input 1Dialogue Remote graphic display terminal, SoMove setup software (1)Communication Integrated Modbus and CANopenAs an optionFipio, Ethernet, Modbus Plus, PROFIBUS DP, DeviceNet, Uni-Telway, INTERBUSCards (available as an option)Encoder interface cards, I/O extension cards, “Controller Inside” programmable card,Encoder emulation cardReduction of current harmonicsIntegrated DC choke or supplied with the productEMC filter Integrated C2 EMC up to 5.5 kWAs an optionExternal C2 EMC from 7.5 kWMotor power kW / HP / A 4 / 5 / 10 – ATV71LD10N4Z T45,5 / 7,5 / 14 – ATV71LD14N4Z T45,5 / 7,5 / 27 ATV71LD27M3Z T5B –7,5 / 10 / 17 – ATV71LD17N4Z T5A7,5 / 10 / 33 ATV71LD33M3Z T5B –11 / 15 / 27 – ATV71LD27N4Z T5B11 / 15 / 54 ATV71LD54M3Z T6 –15 / 20 / 33 – ATV71LD33N4Z T5B15 / 20 / 66 ATV71LD66M3Z T6 –22 / 30 / 48 – ATV71LD48N4Z T7(1) SoMove setup software : available from 2011. Altivar LIFT is also supported by Powersuite software workshop.2345678910Other versions: please consult our Customer Care Centre.4/35


Altivar 710.37…2000 kWComplex, high-power machinesI/O extension and specific cards123Type of cardDescriptionI/O extensionLogic1 relay logic output (“C/O” contact)4 x 24 VDC positive or negative logic inputs2 x 24 VDC open collector positive or negative logicoutputs1 input for PTC probesExtendedReference VW3A3201 VW3A32021 x 0…20 mA differential current analog input1 software-configurable voltage (0…10 VDC) orcurrent (0…20 mA) analog input2 software-configurable voltage (±10V, 0…10 VDC)or current (0…20 mA) analog inputs1 relay logic output (“C/O” contact)4 x 24 VDC positive or negative logic inputs2 x 24 VDC open collector positive or negative logicoutputs, 1 input for PTC probes, 1 frequency controlinput45"Controller Inside" programmable card678Type of cardDescriptionReferenceProgrammable “Controller Inside”10 logic inputs, 2 of which can be used for 2 counters or4 of which can be used for 2 incremental encoders2 analog inputs, 6 logic outputs, 2 analog outputs, a master port for the CANopen bus, a PC port forprogramming with the PS 1131 software workshopVW3A35019104/36Other versions: please consult our Customer Care Centre.


Encoder interface cards1Type of cardEncoder interface withDifferential outputs (RS422) Open collector outputs (NPN) Push-pull outputsOperating frequency300 kHzReference 5 V VW3A3401 – –12 V – VW3A3403 VW3A340515 V VW3A3402 VW3A3404 VW3A340624 V – – VW3A340723Type of card (1) Resolver Universal Sincos Absolute Incremental withemulationSpeed feedback resolution 12 bits 16 bits 16 bits 10,000Encoder type supportedResolver with2, 4, 6 or 8 poles"SinCos,SinCosHiperfaceEnDat, SSI"Sincos Absolute "IncrementalRS 422 - 5 V or 15 V"References VW3A3408 VW3A3409 VW3A3410 VW3A3411Supported by Altivar LIFT and Altivar71 with S383 firmware version45678910Other versions: please consult our Customer Care Centre.4/37


AccessoriesOptionsSelection guideFor Altistart and Altivar range1234Communication toolsRemote displayterminal(IP54 & IP65)Remotegraphic displayterminalMulti-loader Simple Loader DongleBluetooth®(TM)Altistart 01Altistart 22 x xAltistart 48xAltivar 12 x x x xAltivar 212 x x x xAltivar 312 x x x x xAltivar 31C x x xAltivar 32 x x x xAltivar LIFT x x x xAltivar 61 x x x xAltivar 71 x x x xAltivar 61 Plus x x x xAltivar 71 Plus x x x xAltivar 61Q (Water Cooled) x x x xAltivar 71Q (Water Cooled) x x x x56789Accessories & Options ALTISTART ALTIVAR01 22 48 12 21 212 312 31C 32 61 71 LIFT 61 Plus 71 Plus 61Q 71QPanel cut-out adaptor for mounting control unit at 90°xFerrite suppressors for downstream contactor opening x x xAdditional EMC filter x x x x x x x x x x xPassive filters x x x x x xSinus filters x x x x x xLine choke x x x x x x x x x x xMotor chokes x x x x x x x x xEMC conformity kitxUL Type 1 conformity kit x xDNV kit x xMechanical base kit for mounting GV2 circuit-breakerxMounting plates x x x x x x xBraking resistors for vertical movementsxBraking resistors and braking units x x x x x x x x xReferencesIf options or accessories not listed, please refer to the Schneider Electric catalogue.For Altivar 1000 or 1100, please consult our Customer Care Centre.104/38Other versions: please consult our Customer Care Centre.


1Industrial protocolsALTISTART ALTIVAR01 22 48 12 212 312 31C 32 61 71 LIFT 61 Plus 71 Plus 61Q 71Q 1000 1100Canopen ● ● ● ● ● ● ● ● ● ● ○CANopen Daisy chain○CC-Link ○ ○ ○ ○ ○ ○ ○DeviceNet Δ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○EtherCAT ○ ● ●Ethernet Δ ●Ethernet IP ○ ○ ○ ○ ○ ○ ○ ○Ethernet TCP/IP ○ ○Fipio ○ ○ ○ ○ ○ ○ ○ ○ ○ ○INTERBUS S ○ ○ ○ ○ ○ ○ ○Modbus ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●Modbus Plus ○ ○ ○ ○ ○ ○ ○Modbus TCP ○ ○ ○ ○ ○ ○ ○ ○ ○Modbus/ Unitelway ○ ○ ○ ○ ○ ○ ○PROFIBUS DP Δ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ●PROFIBUS DP V0 ○ ○ ○ ○ ○ ○ ○ ○PROFIBUS DP V1 ○ ○ ○ ○ ○ ○ ○ ○ReferencesHVAC protocolsPlease refer to the Schneider Electric catalogue or consult our Customer Care Centre.ALTISTART ALTIVAR01 22 48 12 212 312 31C 32 61 71 LIFT 61 Plus 71 Plus 61Q 71Q 1000 1100Lonworks ○ ○ ○ ○Metasys N2 ● ○ ○ ○Apogee FLN ● ○ ○ ○BACnet ● ○ ○ ○References● Embedded ○ Option Δ GatewayPlease refer to the Schneider Electric catalogue or consult our Customer Care Centre.23456Communication modules78Altistart 48/Altivar 31starters/drivesEthernet/ModbusDeviceNet/ModbusFipio/ModbusPROFIBUS DP/ModbusParameter setting – – – StandardconfiguratorABC configuratorprogramReferences Bridge TSXETG100 – – – –Gateway – LUFP9 LUFP1 LA9P307 LUFP7Cable references L = 0.3 m – VW3A8306R03 VW3A8306R03 – VW3A8306R03L = 1 m – VW3A8306R10 VW3A8306R10 VW3P07306R10 VW3A8306R10L = 3 m VW3A8306D30 VW3A8306R30 VW3A8306R30 – VW3A8306R30910Other versions: please consult our Customer Care Centre.4/39


Selection guideC Applications :Lexium 32 is the perfect drivesystem for applications involvinghigh-precision, dynamic positioning.C Applications :Lexium SDx stepper drives andmotors are used for short-distancepositioning applications requiringmaximum accuracy and high torque.Servo Drives Servo Motors Stepper Drives Stepper MotorsLexium 32 Lexium BMH Lexium SD2 Lexium BRS24Lexium BSH Lexium SD3 Lexium BRS3MachinesPackaging machinesMaterial handling machinesMaterial working machinesAssembling machinesPrinting machinesLabelling machinesScreen printing machinesDescriptionThe Lexium 32 servo range consists of threehigh-performance book-size servo drivemodels – Lexium 32 Compact, Lexium 32Advanced and Lexium 32 Modular – andtwo motor families – the versatile mediuminertiaLexium BMH and the dynamic lowinertiaLexium BSH.The Lexium SDx stepper motor drive rangeconsists of two high-precision stepper drivelines – the three-phase stepper drivesLexium SD3 and the two-phase stepperdrives Lexium SD2. These drive lines arecomplemented by two perfectly matchedstepper motor families – Lexium BRS3 threephasestepper motors and Lexium BRS2two-phase stepper motors.Power range 0.15…7 kW up to 750 WVoltage range 115…240 VAC, 400…480 VAC 24…48 VDC, 115…240 VACSpeed up to 8000 rpm up to 1000 rpmTorque up to 84 Nm up to 16.5 NmCommunication interfacesCANopen, CANmotion, PROFIBUS DP,DeviceNet, EtherNet/IPCANopen, CANmotion, PROFIBUS DP orPulse/DirectionSafety function (STO) on boardEnhanced Safety Module (SS1, SS2, SLS,SOS)Encoder module for digital and analogencoders and resolversSafety function (STO) on board(Lexium SD3 28)4/40Other versions: Please consult your Schneider Electric sales office.


C Applications :Lexium Integrated Drives allow for extremely space-savingdecentralised motion solutions.C Applications :The Lexium Linear Motion products are designed formaximum flexibility, performance and cost-effectiveness.This range offers products for all linear movements in theautomation industry from single-axis to multi-axis systems.Integrated DrivesLinear MotionLexium ILA Lexium ILE Lexium ILS Lexium PAS Lexium CAS4Lexium ILP / ILT Lexium TAS Lexium MAXFormat adjustmentPrinting machinesMaterial handling machinesThe Lexium ILx Integrated Drives comprise motor, positioning controller,power electronics, fi eldbus and “Safe Torque Off” safety function in anextremely compact single device. Lexium ILx Integrated Drives are availablewith all important motor technologies (servo, brushless DC, stepper).Material handling machinesMaterial working machinesOn-the-fl y working machinesAssembling machinesLexium Linear Motion is a comprehensive linear motion rangecomprising Lexium PAS portal axes, Lexium TAS linear tables, LexiumCAS cantilever and telescopic axes and Lexium MAXmulti-axis systems.100…370 W Single axes:24…48 VDC, 115 to 240 VAC Stroke up to 5.5 mup to 9000 rpmLoad up to 150 kgup to 12 NmSpeed up to 8 m/sRS485, CANopen, PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCAT,Ethernet POWERLINK, Modbus TCP, Pulse/DirectionSafety function (STO) on board(Lexium ILA, Lexium ILE, Lexium ILS)Stand-alone device with controller inside (Lexium ILP)Multi axes:Stroke up to 5.5 mLoad up to 130 kgSpeed up to 4 m/sAvailable as individual components or completelypre-assembled, customised systems with drives and motorsOther versions: Please consult your Schneider Electric sales office.4/41


Selection guideC Applications :Lexium Motion Controllers can be used as a stand-alone motion andautomation controllers for machines without a PLC or as pure motioncontrollers for machines in which a PLC takes care of automation control.Axis controllerLexium Motion Controllers4MachinesDescriptionPackaging machinesMaterial handling machinesMaterial working machinesAssembling machinesThe compact LMC Lexium Motion Controllers are used to control multiple synchronisedaxes via a motion bus and feature high performance coupled with economy.Technical informationSynchronisation of up to 4 axes in 2 msSynchronisation of up to 8 axes in 4 msPLCopen function blocks single / multi axis controlApplication function blocks (Rotary knife, Flying shear, Clamping, Grouping/Ungrouping)Communication interfacesModbus, CANmotion, Profibus DP, DeviceNet, Ethernet TCP/IP (for programming)4/42Other versions: please consult our Customer Care Centre.


Lexium ControllerMotion controlMotion controllerController type Optimised Standard ExtendedDrive synchronisation Up to 4 axes 2 msCAN Motion bus Up to 8 axes 4 msInterpolation of drive position loops250 μsInternal memory RAM 1 MBFlash Eeprom1 MBProtected RAM60 KbExpert application Application function blocks yesSingle-axis PLCopen control yesMulti-axis PLCopen control yes2D interpolationyesNumber of logic inputs8 + 4 Fast inputsNumber of logic outputs 8 8Communication Modbus yes yes yes yesCANopen automation – yes yes yesEthernet TCP/IP – yes yes yesProfibus DP V1 – – yes –Device Net – – – yesReference LMC10 LMC20 LMC20A1307 LMC20A13094Software solutionsEasy Motion… for configuringmotion control functionsb Axis parameter settingb Drive and controller adjustment and diagnosticsb Creation of position registers via the Teach functionb Management of axis operating modes and manual controlb Configuration of positioning tasksb Editing cam profilesb Application back up and restoreMotion Pro… for configuring and programmingmotion control functionsb Retains the same benefits as Easy Motion mode for motion controlb Creates the whole application, control system function and motion controlfunction, using the programming editor conforming to standard IEC 61131b Saves the machine signatureb Protection of application programsOther versions: please consult our Customer Care Centre.4/43


Lexium 32Motion controlLexium 32 Servo Drives and Motors1Main functions Lexium 32 Compact Lexium 32 Advanced Lexium 32 Modular2345678Communication Integrated Modbus serial linkPulse trainModbus serial linkCANopen, CANmotion machine busModbus serial linkPulse trainAs an option – – CANopen, CANmotion machinebus, DeviceNet, EtherNet/IP,PROFIBUS DPOperating modesFunctionsManual mode (JOG)Electronic gearboxSpeed controlCurrent controlHomingManual mode (JOG)Speed controlCurrent controlPosition controlAuto-tuning, monitoring, stopping, conversion– Stop windowRapid entry of position valuesHomingManual mode (JOG)Motion sequenceElectronic gearboxSpeed controlCurrent controlPosition controlStop windowRapid entry of position valuesRotary axesPosition register24 V c logic inputs 6, reassignable 3, reassignable 4, reassignable24 V c capture inputs (1) (2) – 1 224 V c logic outputs (1) 5, reassignable 2, reassignable 3, reassignableAnalog inputs 2 –Pulse control input1, configurable as: RS 422 link5 V or 24 V push-pull5 V or 24 V open collectorESIM PTO outputRS 422 linkSafety functions Integrated “Safe Torque Off” STOAs an option – Safe Stop 1 (SS1) and Safe Stop 2(SS2)Safe Operating Stop (SOS)Safe Limited Speed (SLS)Sensor Integrated SinCos Hiperface ® sensorAs an option – Resolver encoderAnalog encoderDigital encoderArchitectureControl via:Logic or analog I/OControl via:Motion controller via CANopenand CANmotion machine busType of servo drive LXM 32C LXM 32A LXM 32MControl via:Schneider Electric or third-partyPLCs via communication busesand networks9104/44Other versions: please consult our Customer Care Centre.


1Main functionsApplication type High load, With robust adjustment of the movement High dynamic range, Power densityFlange size 70, 100, 140 and 205 mm 55, 70, 100 and 140 mmContinuous stall torque 1.2 to 84 Nm 0.5 to 33.4 NmEncoder typeSingle turn SinCos: 32,768 points/turnand 131,072 points/turnMultiturn SinCos: 32,768 points/turn x 4096 turnsand 131,072 points/turn x 4096 turnsDegree of protection Casing IP 65 (IP 67 conformity kit as an option)Shaft endIP 50 or IP 65 (IP 67 conformity kit as an option)Type of servo motor Lexium BMH Lexium BSHSingle turn SinCos: 131,072 points/turnMultiturn SinCos: 131,072 points/turn x 4096 turns2345678910Other versions: please consult our Customer Care Centre.4/45


Lexium 32Lexium 32 motion controlServo drive/servo motor combinations1Lexium 32 servo drive/BMH or BSH servo motor combinations2345Servo motorsBMH(IP50, IP65 or IP67)Type ofservo motorRotorinertiaBSH(IP50, IP65 or IP67)Type ofservo motorRotorinertiaLexium 32C, 32A and 32M servo drives100…120 V single-phase supply voltage with integrated EMC filterLXM 32pU90M2Continuous output current: 3 A rmsNominal operating pointNominaltorqueNominalspeedNominalpowerStall torqueskgcm 2 kgcm 2 Nm rpm W Nm/NmBSH 0551T 0.06 0.49 3000 150 0.5/1.5BSH 0552T 0.10 0.77 3000 250 0.8/1.9BSH 0553T 0.13BMH 0701T 0.59BSH 0701T 0.25BSH 0702T 0.41BMH 0702T 1.13BMH 0703T 1.67BSH 1001T 1.40BMH1001T 3.2BMH1002T 6.3M 0/M max6Lexium 32 servo drive/BMH or BSH servo motor combinations78910Servo motorsBMH(IP50, IP65 or IP67)Type ofservo motorRotorinertiaBMH 0701T 0.59BMH 0702T 1.13BMH 0703T 1.67BMH 1001T 3.2BMH 1002T 6.3BMH 1003T 9.4BMH 1401P 16.5BSH(IP 50, IP65 or IP67)Type ofservo motorRotorinertiaLexium 32C, 32A and 32M servo drives200…240 V single-phase supply voltage with integrated EMC filterLXM 32pU45M2Continuous output current: 1.5 A rmsNominal operating pointNominaltorqueNominalspeedNominalpowerStall torquesM 0/M maxkgcm 2 kgcm 2 Nm rpm W Nm/NmBSH 0551T 0.06 0.45 6000 300 0.5/1.4BSH 0552T 0.10BSH 0553T 0.13BSH 0701T 0.25BSH 0702T 0.41BSH 0703T 0.58BSH 1001T 1.40BSH 1002T 2.314/46Other versions: please consult our Customer Care Centre.


1LXM 32pU18M2LXM 32pD30M2Continuous output current: 6 A rmsContinuous output current: 10 A rmsNominal operating point Stall torques Nominal operating point Stall torquesNominaltorqueNominalspeedNominalpowerM 0/M maxNominaltorqueNominalspeedNominalpowerNm rpm W Nm/Nm Nm rpm W Nm/NmM 0/M max231.14 3000 350 1.2/3.31.35 2500 350 1.4/4.21.36 2500 350 1.4/3.52.07 2500 550 2.2/6.12.3 2500 600 2.5/6.43.1 2000 650 3.4/8.72.75 2500 700 3.3/6.33.3 2000 700 3.4/8.93.5 2000 750 6/10.3456LXM 32pU90 M2LXM 32pD18M2LXM 32pD30M2Continuous output current: 3 A rmsContinuous output current: 6 A rmsContinuous output current: 10 A rmsNominal operating point Stall torques Nominal operating point Stall torques Nominal operating point Stall torquesNominaltorqueNominalspeedNominalpowerM 0/M maxNominaltorqueNominalspeedNominalpowerM 0/M maxNominaltorqueNominalspeedNominalpowerNm rpm W Nm/Nm Nm rpm W Nm/Nm Nm rpm W Nm/NmM 0/M max780.74 6000 450 0.8/2.50.84 6000 550 1.2/30.94 5000 500 1.3/3.51.1 4000 450 1.4/41.8 5000 950 2.2/7.22.1 4000 900 2.6/7.42.1 4000 900 2.5/7.42.2 4000 900 2.7/7.52.9 3000 900 3.4/10.22.8 3000 900 3.4/10.23.7 4000 1500 5.8/16.44.6 3000 1450 6/18.45.6 2500 1450 8.2/22.86.9 2000 1450 10.3/30.8910Other versions: please consult our Customer Care Centre.4/47


Lexium 32Lexium 32 motion controlServo drive/servo motor combinations1Lexium 32 servo drive/BMH or BSH servo motor combinations2345678Servo motorsBMH(IP50, IP65 or IP67)Type ofservo motorRotorinertiaBSH(IP50, IP 65 or IP67)Type ofservo motorRotorinertiaLexium 32C, 32A and 32M servo drives380…480 V three-phase supply voltage with integrated EMC filterLXM 32pU60N4LXM 32pD12N4Continuous output current: 1.5 A rmsContinuous output current: 3 A rmsNominal operating point Stall torques Nominal operating point Stall torquesNominaltorqueNominalspeedNominalpowerM 0/M maxNominaltorqueNominalspeedNominalpowerkgcm 2 kgcm 2 Nm rpm W Nm/Nm Nm rpm W Nm/NmBSH 0551P 0.06 0.48 6000 300 0.5/1.5BSH 0552P 0.10 0.65 6000 400 0.8/2.5BSH 0553P 0.13 0.65 6000 400 1.05/3.5BMH 0701P 0.59 1.1 3000 350 1.2/4.2BMH 0701P 0.59 1.3 5000 700 1.4/4.2M 0/M maxBSH 0701P 0.25 1.32 5000 700 1.4/3.5BSH 0702P 0.41 1.64 5000 850 2.2/7.6BMH 1001P 3.2 1.9 4000 800 3.3/10.8BMH 0702P 1.13 2.2 3000 700 2.5/7.4BMH 0703P 1.67BMH 1001P 3.2BMH 1002P 6.3BMH 1003P 9.4BMH 1401P 16.5BMH 1402P 32.0BMH 1403P 47.5BMH 2051P 71.4BMH 2052P 129BMH 2053P 190BSH 0703P 0.58BSH 1001P 1.40BSH 1002P 2.31BSH 1003P 3.2BSH 1004P 4.2BSH 1401P 7.4BSH 1402T 12.7BSH 1403T 17.9BSH 1404P 23.79104/48Other versions: please consult our Customer Care Centre.


12LXM 32pD18N4Continuous output current: 6 A rmsLXM 32pD30N4Continuous output current: 10 A rmsLXM 32pD72N4Continuous output current: 24 A rmsNominal operating point Stall torques Nominal operating point Stall torques Nominal operating point Stall torquesNominaltorqueNominalspeedNominalpowerM 0/M maxNominaltorqueNominalspeedNominalpowerM 0/M maxNominaltorqueNominalspeedNominalpowerNm rpm W Nm/Nm Nm rpm W Nm/Nm Nm rpm W Nm/NmM 0/M max342.4 5000 1300 3.4/10.22.44 5000 1300 3.1/11.32.7 4000 1100 3.3/9.63.1 4000 1300 3.4/10.23.9 4000 1600 6.2/18.44 4000 1700 5.8/18.36.2 4000 2600 8.4/25.16.3 3000 2000 8/28.37.6 3000 2400 10.3/30.88.3 2500 2100 10/37.99.5 2500 2500 11.1/2712.1 3000 3800 16.8/50.312.3 3000 3900 19.5/59.312.9 3000 4100 27.8/90.214.2 3000 4500 24/71.819 2500 5000 33.4/103.625.8 2000 5400 34.4/103.441.6 1500 6500 62.5/17052.2 1200 6500 84/2325678910Other versions: please consult our Customer Care Centre.4/49


Lexium 32Motion ControlConfiguration tools1Multi-Loader configuration tool23UseReference VW3 A8 121For downloading configurations from a PC or drive and duplicating them on another drive.The drives do not need to be powered-up.Supplied with:1 cordset equipped with 2 RJ45 connectors1 cordset equipped with one type A USB connector and one mini B USB connector1 x 2 GB SD memory card1 x female/female RJ 45 adaptor4 AA 1.5 V LR6 round batteries45Single memory cardPack of 25 memory cards6UseUsed to store parameters of the Lexium 32 servo drive.Another Lexium 32 servo drive can be commissioned immediately if the application is undergoingmaintenance or duplication.Reference VW3 M8 705 VW3 M8 7047UseReferenceMemory card recorderWrites data from the Lexium 32 servo drive to the memory card.This recorder is not supplied by Schneider Electric.See the User's manual8SoMove setup software9The SoMove setup software is used to configure, adjust, debug and maintain the Lexium 32 servo drive,as for all other Schneider Electric variable speed drives and starters.It communicates via Bluetooth® wireless link with the servo drive, which is equipped with the Modbus-Bluetooth® adaptor (VW3 A8 114).SoMove Mobile application for mobile phone10The SoMove Mobile software converts any compatible mobile phone into a remote graphic displayterminal, offering an identical Human-Machine Interface.Particularly suitable for on-site or remote maintenance operations, the SoMove Mobile software can beused to print out and save configurations, import them from a PC and export them to a PC, or to a servodrive equipped with the Modbus adaptor via the Bluetooth® wireless link.4/50Other versions: please consult our Customer Care Centre.


Lexium 32Motion ControlModules for Lexium 32M1Communication modulesLexium 32M can be connected to the following communication buses and networks: CANopen and CANmotion, DeviceNet, Profibus DP V1, EtherNet/IPReference CANopen / CANmotion module with 2 * RJ 45 connectors VW3 A3 608CANopen / CANmotion module with SUB-D 9 connector VW3 A3 618DeviceNet module VW3 M3 301Profibus DP V1 module VW3 A3 607EtherNet/IP module VW3 A3 616Module CANopen / CANmotion avec bornier 5 points de vis VW3 A3 628Module EtherCAT with 5 points screw terminal VW3 A3 60123Second encoder modulesMachineMotorLexium 32M has an input for an additional encoder to connect third party motor (motor encoder) or to improve positioning accuracy (machine encoder)Reference Module for resolver encoder VW3 M3 401 xModule for digital encoder (A/B/I, BiSS, EndDat 2.2, SSI) VW3 M3 402 xModule for analog encoder (1 Vpp/Hall, 1 Vpp, Hiperface) VW3 M3 403 x (Hiperface only) x45Safety moduleeSM safety module allows Lexium 32M servo drives to access additionnal IEC/EN 61800-5-2 safety functions: SS1, SS2, SLS, SOSReference eSM safety module allows VW3 M3 501DescriptionFrom servo motorConnection elementsPower cordsetsCables equipped with one M23 industrial connector(servo motor end)Cables equipped with oneM40 industrial connector(servo motor end)BMH 070pp, BMH 100pp, BMH 1402P, BMH 1403P BMH 205pP, BSH 1402T,BMH 1401P, BSH 055pp,BSH 1403T, BSH 1404PBSH 070pp, BSH 100pp,BSH 1401PTo servo drive LXM 32pppppp LXM 32pD72N4 LXM 32pD72N4Composition [(4 x 1.5 mm 2 ) + (2 x 1 mm 2 )] [(4 x 2.5 mm 2 ) + (2 x 1 mm 2 )] [(4 x 4 mm 2 ) + (2 x 1 mm 2 )]Length 3 m 3 m 3 mReference VW3 M5 101 R30 VW3 M5 102 R30 VW3 M5 103 R306789Encoder cordsetsDescriptionFrom servo motorTo servo driveSinCos Hiperface ® encoder cables equipped with an M23 industrial connector (servo motor end)and an RJ45 connector with 8 + 2 contacts (servo drive end)BMH ppppp, BSH pppppLXM 32ppppppComposition [3 x (2 x 0.14 mm 2 ) + (2 x 0.34 mm 2 )]LengthReference3 mVW3 M8 102 R3010Other versions: please consult our Customer Care Centre.4/51


Lexium SDpMotion ControlStepper drives and stepper motors1Assignment of BRS2 2-phase stepper motors and SD2 stepper motor drives23BRS2 2-phase stepper motors SD21ppU20C SD21ppU50C24…48 V; 3 A 24…48 V; 5 ABRS236 0.07 Nm –BRS242 0.23…0.53 Nm –BRS257 0.64…1.69 Nm 0.64…1.69 NmBRS285 – 2.96…9.20 Nm456Assignment of BRS3 3-phase stepper motors and SD3 stepper motor drivesBRS3 3-phase stepper motors SD326pU25 SD328pU25 SD326pU68 SD328pU68115 V / 230 V; 2.5 A; including mains filter 115 V / 230 V; 6.8 A; including mains fi lter and fanBRS368 1.7 Nm / 1.5 Nm –BRS397 2.3 Nm / 2.0 Nm –BRS39A 4.5 Nm / 4.0 Nm –BRS39B 6.8 Nm / 6.0 Nm –BRS3AC – 13.5 Nm / 12.0 NmBRS3AD – 19.7 Nm / 16.5 Nm78910Assignment of stepper motors, stepper motor drives SD3 153-phase stepper motors SD3 1524…48 VDC; max. 10 AMotors with F windingBRS 364F0.46 Nm / 0.40 NmBRS 366F0.92 Nm / 0.80 NmBRS 368F1.50 Nm / 1.30 NmBRS 397F2.00 Nm / 1.85 NmBRS 39AF4.20 Nm / 3.40 NmBRS 39BF5.55 Nm / 4.80 NmMotors with H windingBRS 364H0.51 Nm / 0.45 NmBRS 366H1.02 Nm / 0.90 NmBRS 368F1.70 Nm / 1.50 NmBRS 397H2.26 Nm / 2.00 NmBRS 39AH4.80 Nm / 4.00 NmBRS 39BH6.50 Nm / 5.75 Nm4/52Other versions: please consult our Customer Care Centre.


Lexium ILpMotion ControlLexium Integrated Drives1Integrated Drives Lexium ILA Lexium ILE Lexium ILS Lexium ILP / ILTType of processType of technologyDynamic process andaccurate positioningIntegrated drive withservo motorAutomatic formatadjustementIntegrated drive withdc brushless motorShort distance movements with accurate positioningIntegrated drive withthree-phase stepper motorIntegrated drive withtwo-phase stepper motor2Main characteristicsHighly dynamicCompactIntegrated holdingbrake in optionHight holding torquewithout powerIntegrated gearboxin optionHight torque at low speedDynamic gggg gg ggg gggPrecision and stability gggg gg gggg ggggEnergy saving ggggg gggg gg ggMotor inertiaMediumControl interface Control signals Input/output Pulse/directionInput/outputBus and networksCANopen, PROFIBUS DP, RS 485 serial link, DeviceNet, EtherCAT, ModbusTCP, Ethernet Powerlink, EtherNet/IPAssociationDrive/motorcombinationsDrivecharacteristicsMotion bus –Pulse/directionInput/outputCANopen, RS485Nominal power 150...305W 100...350W 100...350W 100...350WNominal speed 500...9000 min -1 1500...7000 min -1 0...1000 min -1 0...1000 min -1Nominal torque 0.26...0.78 Nm 0.18...0.5 Nm 0.45...6 Nm 0.11...5.87 NmSafety function“Safe Torque Off”Motor characteristics Type of sensor (resolution) (1) Single turn SinCosencoder(16.384 increments/turn)Multiturn SinCos encoder(16.384 increments/turn× 4096 turns)Absolute value encoder(12...1380 increments/turn)Index pulse monitoringAccessoriesIndex pulse monitoringMotor flange size 57 66 57, 85 36, 42, 57, 85Cable, Connector kits, Installation sets, Commissioning tools, PlanetarygearboxesCable, Connector kits,Installation sets,Commissioning toolsReferences ILA ILE ILS ILP ILT345678910Other versions: please consult our Customer Care Centre.4/53


Lexium ILA/ILE/ILSMotion ControlLexium Integrated Drives123Lexium ILA with Servo MotorNominal Torque(Nm)ILS1 for CANopen, PROFIBUS DP, RS485, Pulse-Direction, Motion Sequence ModeMaximum Torque(Nm)Nominal Speed(Rpm)Maximum Speed(Rpm)ILA1p571P 0.26 0.6 5500 7500 150ILA1p571T 0.26 0.43 7500 11500 200ILA1p572P 0.45 0.72 4300 6200 200ILA1p572T 0.41 0.61 5000 7500 215ILA2 for DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, Ethernet PowerlinkILA2p571P 0.44 0.62 5100 7000 235ILA2p571T 0.31 0.45 7000 9000 255ILA2p572P 0.78 1.62 3400 4300 275ILA2p572T 0.57 0.85 5100 6800 305Nominal Power(W)456Lexium ILE with included spurwheel gearbox.Ratios:18:1, 38:1, 54:1, 115:1Lexium ILE with included worm gearbox with hollow shaft.Ratios: 24:1, 54:1, 92:1, 115:1Lexium ILE with Brushless DC MotorNominal Torque(Nm)Detent Torque(Nm)Nominal Speed(Rpm)ILE1 for CANopen, PROFIBUS DP, RS485ILE1p661 0.24 0.08 4800 5000ILE1p661 spurwheel gearing up to 11.0 up to 8.0 44 44ILE1p661 worm gearing up to 10.6 up to 16.7 44 44ILA2 for DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, Ethernet PowerlinkILE2p661 0.26 0.08 6000 7000ILE2p661 spurwheel gearing up to 12 up to 9.19 44 44ILE2p661 worm gearing up to 10.6 up to 16.7 44 44ILE2p662 0.5 0.106 5000 7000Maximum Speed(Rpm)78910Lexium ILS with three-phase Stepper MotorMaximum Torque(Nm)ILS1 for CANopen, PROFIBUS DP, RS485, Pulse-Direction, Motion Sequence ModeHolding Torque(Nm)ILS1p571p 0.45 0.51 1000ILS1p572p 0.9 1.02 600ILS1p573p 1.5 1.7 450ILS1p851p 2.0 2.0 450ILS1p852p 4.0 4.0 200ILS1p853P 6.0 6.0 120ILS1p853T 4.5 4.5 300ILS1 for CANopen, PROFIBUS DP, RS485, Pulse-Direction, Motion Sequence ModeILS2p571p 0.45 0.51 1100ILS2p572p 0.9 1.02 900ILS2p573p 1.5 1.7 600ILS2p851p 2.0 2.0 600ILS2p852p 4.0 4.0 380ILS2p853P 6.0 6.0 200ILS2p853T 4.5 4.5 300Speed(Rpm)4/54Other versions: please consult our Customer Care Centre.


Lexium ILP/ILTMotion ControlLexium Integrated Drives1Lexium ILP, Lexium ILT with two-phase Stepper MotorNominal Torque(Nm)Holding Torque(Nm)ILP for RS485 with programmable interfaceILP2R361 0.11 0.11 1800ILP2R421 0.19 0.19 1500ILP2R422 0.33 0.33 1500ILP2R423 0.39 0.39 1500ILP2R571 0.63 0.63 1500ILP2R572 0.86 0.86 1500ILP2R573 1.44 1.44 1500ILP2R574 1.77 1.77 1500ILP2R851 2.13 2.13 1000ILP2R852 3.12 3.12 1000ILP2R853 5.87 5.87 1000ILT for Pulse/Direction, CANopenILT2p361 0.11 0.11 1800ILT2p421 0.19 0.19 1500ILT2p422 0.33 0.33 1500ILT2p423 0.39 0.39 1500ILT2p571 0.63 0.63 1500ILT2p572 0.86 0.86 1500ILT2p573 1.44 1.44 1500ILT2p574 1.77 1.77 1500ILT2p851 2.13 2.13 1000ILT2p852 3.12 3.12 1000ILT2p853 5.87 5.87 1000Maximum Speed(Rpm)2345678910Other versions: please consult our Customer Care Centre.4/55


Lexium Linear MotionMotion ControlLinear axes1Product Lexium PAS B Lexium PAS S2Axis typePortal axesMovement Number of directions 13Movement typeTypically horizontalPosition of the loadOn carriageDrive Toothed belt BallscrewType of guide Ball or roller BallMain characteristicsHigh dynamic response, Long stroke length, Highpositioning speedHigh precision movement (positioning, repeatability,guiding), High feed forces, High rigidity45Dynamic response ggggg gggPrecision ggg gggggMaximum payload 100 kg 100 kgMaximum driving force 2600 N 4520 NMaximum speed of movement of the load 8 m/s 1.25 m/sMaximum working stroke 5500 mm 3000 mmRepeatability ± 0.05 mm ± 0.02 mmOptionsChoice of guide type: Ball (for applications requiringhigh forces and torques) or roller (simple, costeffectivesolution), Wide range of sensors, Choice ofcarriage type for adapting to the load, Option to addcarriages, Protective metal strip.Choice of pitch , Protective metal strip, Wide range ofsensors, Choice of carriage type for adapting to theload, Option to add carriages, Option to addballscrew supports for longer axesReference PAS 4pB PAS 4pS6Multi-axis systems7Product Lexium MAX H Lexium MAX S8Axis typeDouble portal axesMovement Number of directions 1Movement typeCombination of two parallel axesZMulti-axis system typePosition of the loadXYOn two parallel carriagesPAS 4pB axes + PAS 4pH support axis(driven by the load)PAS 4pB + PAS 4pB axes(shaft-driven)9Drive Toothed belt on one axis Toothed belt on both axesType of guide Ball or roller Ball or rollerMain characteristicsLong stroke length, High dynamic response, Highprecision movement (positioning, guiding)Long stroke length, High precision movement(positioning, guiding), High feed forcesMaximum payload 250 kg 300 kg10Maximum workingstrokeOptionsOn the X-axis5500 mmOn the Y-axis –On the Z-axis –Choice of guide type: Ball (for applications requiring high forces and torques) or roller (simple, cost-effectivesolution), Protective metal strip, Anti-corrosion version, Anti-static belt, Wide range of sensors, Severaldifferent motor mounting options, Variable distance between the two axesReference MAX H MAX S4/56Other versions: please consult our Customer Care Centre.


1Lexium TAS Lexium CAS 4 Lexium CAS 3 Lexium CAS 2Linear tablesCantilever axes with mobile structure onprofileCantilever axes with mobile structure onparallel rodsTelescopic axes1Typically horizontal Typically vertical Typically horizontalOn carriage On the side of the profile or on the 2 end blocks On the 2 end blocks On carriageBallscrew Toothed belt Toothed belt or rack Toothed beltDouble, ball Ball or roller Ball Ball or rollerHigh precision movement (positioning,repeatability, guiding), High feed forces,High rigidity, Feed movement withoutmechanical backlashLong stroke length, High feed forces, Option Compact, Mobile structure with light travelto mount the load on the side of the profile or weighton the end blocks, High rigiditygg gggg gggg gggggggggg ggg ggg gg150 kg 50 kg 18 kg 35 kg2580 N 2150 N 705 N 1500 N1 m/s 3 m/s 3 m/s 3 m/s1500 mm 1200 mm 500 mm 2400 mm± 0.02 mm ± 0.05 mm ± 0.05 mm ± 0.1 mmChoice of pitch , Several different motormounting optionsChoice of guide type: Ball (for applicationsrequiring high forces and torques) or roller(simple, cost-effective solution), Protectivemetal strip, Anti-corrosion version, Widerange of sensorsAnti-corrosion version, Anti-static beltTAS 4 CAS 4 CAS 3 CAS 2Long stroke length from a compact unit,High rigidity, High dynamic responseChoice of guide type: Ball (for applicationsrequiring high forces and torques) or roller(simple, cost-effective solution), Choice ofcarriage type for adapting to the load23456Lexium MAX P Lexium MAX R2 Lexium MAX R3Linear positionersPortal robots2 3Horizontal and vertical: Combination of one X-axis and oneZ-axisHorizontal: Combination of two perpendicular axes X and YHorizontal and vertical: Combination of two perpendicularaxes X and Y and one Z-axisOn the side or on the end blocks of the Z-axis profile On the Y-axis carriage On the side or on the end blocks of the Z-axis profileMAX S + CAS 4 axesMAX S + CAS 3 axesToothed belt on each axisBall or rollerMAX S + MAX H axesMAX S + PAS 4pB axesMAX S + MAX H + CAS 4 axesMAX S + MAX H + CAS 3 axesDynamic load positioning Long stroke length on both axes Long stroke length on three axes50 kg 130 kg 50 kg5500 mm– 1500 mm 1500 mm1200 mm – 1200 mmChoice of guide type: Ball (for applications requiring high forces and torques) or roller (simple, cost-effective solution), Wide range of sensorsSupplied as standard: Protective metal strip , Anti-corrosion version78910MAX P MAX Rp2 MAX Rp3Other versions: please consult our Customer Care Centre.4/57


TeSysProtect your machines and installations withTeSys - a comprehensive range of contactors,circuit breakers, starters, motor starters andpower control components.Schneider Electric has beenleading the way in the motorstarter market for more than80 years. Its TeSys productsoffer an extensive range ofinnovative motor protectionand power control solutions.


Motor controlThis document is a selection ofthe top selling products.1Motor control componentsTeSys contactors ......................................................................................................5/2 to 5/11Contactors, TeSys K, D, F, BVariable composition contactors, TeSys CVTeSys protection components ......................................................................... 5/12 to 5/33Thermal-magnetic circuit-breakersMagnetic circuit-breakersFuse carriers, switch-disconnector-fusesThermal overload relaysElectronic thermal overload relaysElectronic overload relaysStarter-controller, TeSys TMultifunction protection relaysSwitch disconnectors Mini Vario and VarioTeSys starters ......................................................................................................... 5/34 to 5/41Combination motor startersStarter-controller, TeSys UController, TeSys UEnclosed motor startersTeSys installation system .................................................................................. 5/42 to 5/43For motor starter components with spring terminals,TeSys Quickfit technologyComponents for power control applications ................................................................ 5/44 to 5/50Lighting, capacitor switching, heating and changeover contactor pairs23456789105/1


TeSys KContactors0.06…5.5 kW1234Connections screw clamp terminalsRated operational current Ie max AC-3 (Ue ≤ 440 V) 6 A 9 A 12 AIe AC-1 (θ ≤ 40° C) - 20 A -Rated operational power 220/240 V 1.5 kW 2.2 kW 3 kWin category AC3 380/400 V…415/440 V 2.2 kW 4 kW 5.5 kW660/690 V…500 V 3 kW 4 kW 4 kWContactor type (1)* a LC1K06•• LC1K09•• LC1K12••c LP1K06•• or LP4K06•• LP1K09 or LP4K09•• LP1K12 or LP4K12••Reversing contactor type * a LC2K06 LC2K09 LC2K12with mechanical interlock c LP2K06 or LP5K06 LP2K09 or LP5K09 LP2K12 or LP5K12b spring terminalsAdd the figure 3 before the voltage code. Example: LC1K0610•• becomes LC1K06103••b Faston connectors, 1 x 6.35 or 2 x 2.8Add the figure 7 before the voltage code. Example: LC1K0610•• becomes LC1K06107••b solder pins for printed circuit boardsAdd the figure 5 before the voltage code. Example: LC1K0610•• becomes LC1K06105••(1) Basic reference, to be completed by adding 01 for NC auxiliary contact, or 10 for NO auxiliary contact.* Basic reference to be completed by adding the coil voltage code56789Standard control circuit voltagesa supplyContactors LC1K (0.8…1.15 Uc) (0.85…1.1 Uc)Volts 12 20 24 36 42 48 110 115 120 127 200/208 220/230 230 230/24050/60 Hz J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7Volts 256 277 380/400 400 400/415 440 480 500 575 600 660/69050/60 Hz W7 UE7 Q7 V7 N7 R7 T7 S7 SC7 X7 Y7Example of complete reference: LC1K0910P7c supplyContactors LP1K (0.8…1.15 Uc)Volts 12 20 24 36 48 60 72 100 110 125 155 174 200 220 230 240 250Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UDCoil with integral suppression device available, add 3 to the code required. Example: JD3Low consumptionContactors LP4K (0.7…1.30 Uc), coil suppression as standardVolts 12 20 24 48 72 110 120Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3Example of complete reference: LC1K0910BD105/2Other versions: please consult our Customer Care Centre.


1Auxiliary contact blocks instantaneous, screw clamp connections for LC1, LP1K, LP4 for LC1, LP1KComposition 2NO - 2NC 1NO 1NC 4NO 3NO 1NC 2NC 2NC 1NO 3NC - 4NCReference LA1KN20 LA1KN02 LA1KN11 LA1KN40 LA1KN31 LA1KN22 LA1KN13 LA1KN04 electronic time delayRelay outputs, with common point changeover contact, a or c 24…48, 2 A maximumControl voltage 0.85…1.1 UcMaximum switching capacity 250 VA or 150 WOperating temperature -10…+ 60°CReset time: 1.5 s during the time delay period, 0.5 s after time delay periodTypeOn-delayTiming range1…30 sComposition 1Voltage a or c 24…48 V a 110…240Reference LA2KT2E LA2KT2U23456Suppressor modulesFor LC1, LP1-KType Varistor (a and c) Diode (c) + Zener RC (a)Voltage 12…24 V 32…48 V 50…129 V 130…250 V 12…24 V 32…48 V 220…250 VReference LA4KE1B LA4KE1E LA4KE1FC LA4KE1UG LA4KC1B LA4KC1E LA4KA1U78910Other versions: please consult our Customer Care Centre.5/3


TeSys DContactors0.06…75 kW12345Connections■ screw clamp terminals or connectorsRated operational voltage690 VRated operational current Ie max AC-3 (Ue ≤ 440 V) 9 A 12 A 18 A 25 A 32 A 38 AIe AC-1 (θ ≤ 60° C) 25 A 32 A 40 A 50 ARated operational power 220/240 V 2.2 kW 3 kW 4 kW 5.5 kW 7.5 kW 9 kWin category AC3 380/400 V 4 kW 5.5 kW 7.5 kW 11 kW 15 kW 18.5 kW415/440 V 4 kW 5.5 kW 9 kW 11 kW 15 kW 18.5 kW500 V 5.5 kW 7.5 kW 10 kW 15 kW 18.5 kW 18.5 kW660/690 V 5.5 kW 7.5 kW 10 kW 15 kW 18.5 kW 18.5 kW1000 V – – – – – –Contactor type * LC1D09 LC1D12 LC1D18 LC1D25 LC1D32 LC1D38Reversing contactor type * with mechanical interlock LC2D09 LC2D12 LC2D18 LC2D25 LC2D32 LC2D38 spring terminals (1)Add the figure 3 before the voltage code. Example: LC1D09P7 becomes LC1-093P7 lug-clamps (2)Add the figure 6 before the voltage code. Example: LC1D09P7 becomes LC1-096P7 Faston connectors (3) 2 x 6.35 (power) and 1 x 6.35 (control) up to D12 onlyAdd the figure 9 before the voltage code. Example: LC1D09P7 becomes LC1-099P7* Basic reference to be completed by adding the coil voltage code6(1) (2)(3)78910Standard control circuit voltagesa supplyVolts 24 42 48 110 115 220 230 240 380 400 415 440 500Contactors LC1D09…D150 (coils D115 and D150 with integral suppression device fitted as standard)50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 S7Contactors LC1D80…D11550 Hz B5 D5 E5 F5 FE5 M5 P5 U5 Q5 V5 N5 R5 S560 Hz B6 - E6 F6 - M6 - U6 Q6 - - R6 -c supplyVolts 12 24 36 48 60 72 110 125 220 250 440Contactors LC1D09…D65A (coils with integral suppression device fitted as standard)U 0.75…1.25 Uc JD BD CD ED ND SD FD GD MD UD RDContactors LC1D80…D95U 0.85…1.1 Uc JD BD CD ED ND SD FD GD MD UD RDU 0.75…1.2 Uc JW BW CW EW - SW FW - MW - -Contactors LC1D115 and D150 (coils with integral suppression device fitted as standard)U 0.75…1.2 Uc - BD - ED ND SD FD GD MD UD RDLow consumptionContactors LC1D09…D38 (coils with integral suppression device fitted as standard)Volts c 5 12 20 24 48 110 120 250U 0.7…1.25 Uc AL JL ZL BL EL FL ML ULExample of complete reference: LC1D09P75/4Other versions: please consult our Customer Care Centre.


1690 V 1000 V on a supply, 690 V on c supply40 A 50 A 65 A 80 A 95 A 115 A 150 A60 A 80 A 80 A 125 A 200 A11 kW 15 kW 18.5 kW 22 kW 25 kW 30 kW 40 kW18.5 kW 22 kW 30 kW 37 kW 45 kW 55 kW 75 kW22 kW 25 kW 30 kW 45 kW 45 kW 59 kW 80 kW22 kW 30 kW 37 kW 55 kW 55 kW 75 kW 90 kW30 kW 33 kW 37 kW 45 kW 45 kW 80 kW 100 kW– – – 45 kW 45 kW 75 kW 90 kWLC1D40A LC1D50A LC1D65A LC1D80 LC1D95 LC1D115 LC1D150LC2D40A LC2D50A LC2D65A LC2D80 LC2D95 LC2D115 LC2D150234Mounting accessories for 3-pole reversing contactors52 identical contactors with screw clamp terminals or connectors, horizontally mountedMechanical interlock Set of connections Mechanical interlock with an electrical interlocking kit for the contactorsLC1-D09…D38 LAD-9R1V included with integral electrical interlockingLC1-D80 and D95 (a) LA9D8069 LA9D4002LC1-D80 and D95 (c) LA9D8069 LA9D8002LC1-D115 and D150 LA9D11569 LA9D11502 without electrical interlockingLC1-D09…D38 LA99R1 includedLC1-D40A…D65A LAD9R3 includedLC1-D80 and D95 (a) LA9D8069 LA9D50978LC1-D80 and D95 (c) LA9D8069 LA9D809786789Mechanical latch blocksClip-on front mounting, manual or electrical unlatching controlFor use on contactor Reference Standard control circuit voltagesLC1D09…D65A a or c, LC1DT20…DT80 a or c LAD6K10• B E F M QLC1D80…D150 3P a, LC1D80 and D115 3P a, LC1D115 4P c LA6DK20• B E F M Q10Other versions: please consult our Customer Care Centre.5/5


TeSys DContactorsAuxiliary contacts1Contact typeinstantaneous, connection by screw terminals23Block mounting Front mounting Side mountingReferences Contact 1 NO LADN10 –1 NC LADN01 –1 NO + 1 NC LADN11 LAD8N112 NO LADN20 LAD8N202 NC LADN02 LAD8N022 NO + 2 NC LADN22 –1 NO + 3 NC LADN13 –3 NO + 1 NC LADN31 –4 NO LADN40 –4 NC LADN04 –45Contact typeTime delay, connection by screw terminals6Block mountingFront mountingTemporisation 0.1…3 s 0.1…30 s 10…180 sReferences On-delay LADT0 LADT2 LADT4Off-delay LADR0 LADR2 LADR4Maximum number of auxiliary contacts that can be fitted78910InstantaneousTime delayType Number of poles Side mounting Front mounting Frontand size on left side on right side 1 contact 2 contacts 4 contacts mountingAC 3P LC1D09…D38 1 – and – 1 or 1 or 1LC1D40A…D65A 1 or 1 and – 1 or 1 or 1LC1D80…95 (50/60 Hz) 1 1 or 2 and 1 or 1 or 1LC1D80…95 (50 or 60 Hz) 1 1 and 2 and 1 or 1 or 1LC1D115 and D150 1 – and – 1 or 1 or 14P LC1DT20…DT40 1 – and – 1 or 1 or 1LC1DT60A…D80A 1 or 1 and – 1 or 1 or 1LC1D115 1 1 and 1 or 1 or 1 or 1DC 3P LC1D09…D38 – – – 1 or 1 or 1LC1D40A…D65A 1 or 1 and – 1 or 1 or 1LC1D80 and 95 – – 1 or 1 or 1 or 1LC1D115 and D150 1 – and – 1 or 1 or 14P LC1DT20…DT40 – – – 1 or 1 or 1LC1DT60A…D80A – – – 1 or 1 or 1LC1D115 1 1 – and 1 or 1 or 1DC low 3P LC1D09…D38 – – – 1 – –consumption4P LC1DT20…DT40 – – – 1 – –5/6Other versions: please consult our Customer Care Centre.


TeSys DContactorsSuppressor modules1Type of moduleRC circuits (Resistor-Capacitor)Mounting Side clip-on Front clip-on Screw fixingFor use with contactor D09…D38(3P) DT20…DT40(4P) D40A…D65A(3P) DT60A…DT80A(4P) D80…D150(3P) D40…D115(4P)References Voltage 24…48 VAC LAD4RCE LAD4RC3E LA4DA2E50…127 VAC LAD4RCG LAD4RC3G LA4DA2G110…240 VAC LAD4RCU LAD4RC3U LA4DA2U380…415 VAC – LAD4RC3N LA4DA2N23Type of moduleVaristors (peak limiting)4Mounting Side clip-on Front clip-on Screw fixingFor use with contactor D09…D38(3P) DT20…DT40(4P) D40A…D65A(3P) DT60A…DT80A(4P) D80…D150(3P) D40…D115(4P)References Voltage 24…48 VAC LAD4VE LAD4V3E LA4DE2E50…127 VAC LAD4VG LAD4V3G LA4DE2G110…240 VAC LAD4VU LAD4V3U LA4DE2U24…48 VDC – – LAD4DE3E (AC and DC)50…127 VDC – – LAD4DE3G (AC and DC)110…240 VDC – – LAD4DE3U (AC and DC)56Type of moduleFlywheel diodesMounting Side clip-on Front clip-on Screw fixingFor use with contactor D09…D38(3P) DT20…DT40(4P) D40A…D65A(3P) DT60A…DT80A(4P) D80…D150(3P) D40…D115(4P)References Voltage 24…250 VDC LAD4DDL LAD4D3U LAD4DC3U78Type of moduleBidirectional peak limiting diodeMounting Side clip-on Front clip-on Screw fixingFor use with contactor D09…D38(3P) DT20…DT40(4P) D40A…D65A(3P) DT60A…DT80A(4P) D80…D150(3P) D40…D115(4P)References Voltage 24 VAC LAD4TB LAD4T3B LA4DB2B24 VDC LAD4TBDL LAD4T3B LA4DB2S72 VAC LAD4TS LAD4T3S LA4DB3B72 VDC LAD4TSDL LAD4T3S LA4DB3S125 VDC LAD4TGDL LAD4T3G (AC and DC) –250 VDC LAD4TUDL LAD4T3U (AC and DC) –600 VDC LAD4TXDL LAD4T3R (AC and DC) –910Other versions: please consult our Customer Care Centre.5/7


TeSys FContactors90…450 kW1234Rated operational current Ie max AC-3 (Ue ≤ 440 V) 185 A 225 A 265 A 330 AIe AC-1 (θ ≤ 40° C) 275 A 315 V 350 A 400 ARated operational voltage 1 000 V 1 000 V 1 000 V 1 000 VNumber of poles 3 or 4 3 or 4 3 or 4 3 or 4Rated operational power 220/240 V 55 kW 63 kW 75 kW 100 kWin category AC3 380/400 V 90 kW 110 kW 132 kW 160 kW415 V 100 kW 110 kW 140 kW 180 kW440 V 100 kW 110 kW 140 kW 200 kW500 V 110 kW 129 kW 160 kW 200 kW660/690 V 110 kW 129 kW 160 kW 220 kW1000 V 100 kW 100 kW 147 kW 160 kWContactor type* LC1F185 LC1F225 LC1F265 LC1F330Reversing contactor type* LC2F185 LC2F225 LC2F265* Basic reference to be completed by adding the coil voltage code5678910Standard control circuit voltagesa supplyVolts 24 48 110 115 120 208 220 230 240 380 400 415 440Contactors LC1F115…F225 (0.85…1.1 Uc)50 Hz (coil LX1) B5 E5 F5 FE5 - - M5 P5 U5 Q5 V5 N5 -60 Hz (coil LX1) - E6 F6 - G6 L6 M6 - U6 Q6 - - R6U740…400 Hz (coil LX9) - E7 F7 FE7 G7 L7 M7 P7 U7 Q7 V7 N7 R7Contactors LC1F265…F330U740…400 Hz (coil LX1) B7 E7 F7 FE7 G7 L7 M7 P7 U7 Q7 V7 N7 R7Contactors LC1F400…F630U740…400 Hz (coil LX1) - E7 F7 FE7 G7 (1) L7 M7 P7 U7 Q7 V7 N7 R7Contactor LC1F780U740…400 Hz (coil LX1) - - F7 FE7 F7 L7 M7 P7 U7 Q7 V7 N7 R7Contactor LC1F800U740…400 Hz (coil LX1) - - FE7 FE7 FE7 - P7 P7 P7 V7 V7 V7 V7Y7c supplyVolts 24 48 110 125 220 230 250 400 440Contactors LC1F115…F330 (0.85…1.1 Uc)(coil LX4-F) BD ED FD GD MD MD UD - RDContactors LC1F400…F630 (0.85…1.1 Uc)(coil LX4-F) - ED FD GD MD - UD - RDContactor LC1F780 (0.85…1.1 Uc)(coil LX4-F) - - FD GD MD - UD - RDContactor LC1F800 (0.85…1.1 Uc)(coil LX4-F) - - FW FW MW MW - QW -Contactor LC1F1250(coil LX4F) - ED FD - MD - UD - - - - - -Contactor LC1F1400(coil LX4F) - - FD GD MD - UD - RD - - - -Example: For a 630 A contactor with a 110 V a coil, order LC1F630F7(1) F7 for LC1-F6305/8Other versions: please consult our Customer Care Centre.


1400 A 500 A 630 A 780 A 800 A - -500 A 700 A 1 000 A 1 600 A 1 000 A 1260 14001 000 V 1 000 V 1 000 V 1 000 V 1 000 V 1000 10002, 3 or 4 2, 3 or 4 2, 3 or 4 3 or 4 3 3 3110 kW 147 kW 200 kW 220 kW 250 kW Sans objets Sans objets200 kW 250 kW 335 kW 400 kW 450 kW en AC1 en AC1220 kW 280 kW 375 kW 425 kW 450 kW - -250 kW 295 kW 400 kW 425 kW 450 kW - -257 kW 355 kW 400 kW 450 kW 450 kW - -280 kW 335 kW 450 kW 475 kW 475 kW - -185 kW 335 kW 450 kW 450 kW 450 kW - -LC1F400 LC1F500 LC1F630 LC1F780 LC1F800 LC1F1250 LC1F1400For customer assembly - -2345Auxiliary contact blocks instantaneous dust & damp protected contacts time delay 1 NO + 1 NCComposition Reference Composition Reference Composition Reference Composition Reference Type Range ReferenceNO NC NO NC NO NC NO NC1 - LADN10 1 1 LADN11 2 2 LADN22 2 - - - LA1DX20 On-delay 0.1…3 s LADT0- 1 LADN01 2 - LADN20 1 3 LADN13 2 2 - - LA1DY20 0.1…30 s LADT2- 2 LADN02 4 - LADN40 2 - 2 - LA1DZ40 10…180 s LADT4- 4 LADN04 2 - 1 1 LA1DZ31 1…30 s LADS23 1 LADN31 Off-delay 0.1…3 s LADR02 2 LADC22 0.1…30 s LADR210…180 s LADR467Mounting accessories for 3-pole reversing contactors for motor control82 identical contactors, horizontally mountedMechanical interlock with an electrical interlocking kit for the contactorsContactor type Set of connections Mechanical interlockLC1F115 LA9FF976 LA9FF970LC1F150 LA9F15076 LA9FF970LC1F185 LA9FG976 LA9FG970LC1F225 LA9F22576 LA9FG970LC1F265 LA9FH976 LA9FJ970LC1F330 LA9FJ976 LA9FJ970LC1F400 LA9FJ976 LA9FJ970LC1F500 LA9FK976 LA9FJ970LC1F630 or LC1F800 LA9FL976 LA9FL970LCIF1250 - -LCIF1400 - -910Other versions: please consult our Customer Care Centre.5/9


TeSys BContactors400…900 kW1234Rated operational current Ie max AC-3 (Ue ≤ 440 V) 750 A 1000 A 1500 A 1800 AIe AC-1 (θ ≤ 40° C) 800 A 1250 V 2000 A 2750 ARated operational voltage 1 000 V 1 000 V 1 000 V 1 000 VNumber of poles 1 to 4 1 to 4 1 to 4 1 to 4Rated operational power 220/240 V 220 kW 280 kW 425 kW 500 kWin category AC3 380/400 V 400 kW 500 kW 750 kW 900 kW415 V 425 kW 530 kW 800 kW 900 kW440 V 450 kW 560 kW 800 kW 900 kW500 V 500 kW 600 kW 700 kW 900 kW660/690 V 560 kW 670 kW 750 kW 900 kW1000 V 530 kW 530 kW 670 kW 750 kW4 instantaneous contact configurations2 NC + 2 NO, 3 NO + 1 NC, 1 NO + 3 NC or 4 NOContactor type* LC1BL LC1BM LC1BP LC1BR* Basic reference to be completed by adding the coil voltage code, followed by the instantaneous contact configuration.56Standard control circuit voltages (for other voltages, please consult your Regional Sales Office)Volts 48 110 125 127 220 230 240 380 400 415 440 500a 50…400 Hz - F - G M P U Q V N R Sc ED FD GD - MD - - - - - RD -Example: To order a 1500 A contactor with 127 V c coil with 3 NO + 1 NC, select LC1BP33G31Mounting accessories7Description For contactor ReferenceBar support bracket LC1BL to BR LA9B103for mounting on 120 or 150 mm centresMechanical interlock and locking device components LC1B EZ2LB060189105/10Other versions: please consult our Customer Care Centre.


TeSysCV1-B, CV3-BContactors, variable compositionCV1-B: 80…1000 A, CV3-B: 80…500 AReference to compiled by the customerContactor type, according to required usea supply 690 V, c supply 220 V/poleCV1Ba supply 1000 V, c supply 440 V/poleCV3BContactor rating CV1: 80 A CV3: 80 A FCV1: 200 A CV3: 170 A GCV1: 300 A CV3: 250 A HCV1: 470 A CV3: 320 A JCV1: 630 A CV3: 500 A KCV1: 1000 ALNumber of poles (PN1 main poles for CV1 and PA3 main poles for CV3)Normally Open main poles 1 NO 12 NO 23 NO 34 NO 45 NO 5Normally Closed main poles 1 NC 12 NC 23 NC 3No main poles 0 Z 0 ZOperational current 10 A E E20 A N N40 A P P80 A F F125 A R R170 A W W200 A G G250 A S S300 A H H320 A T T470 A J J500 A V V630 A K K1000 A L LControl circuit voltage 48 V E110 V F120 V K208 V L220 V M230 V P240 V U380 V Q400 V V440 V ROperating frequency 50 Hz 560 Hz 650/60 Hz 7cDc + economy resistorRInstantaneous auxiliary contactsNormally Open 1 NO 12 NO 23 NO 34 NO 4Normally Closed 1 NC 12 NC 23 NC 34 NC 4Without instantaneous contact 0 0On-delay 1 CO JOff-delay 1 CO NExample 1/ for single-phase capacitor switching: 400 V - 80 A - 1 NO pole - Control circuit 220 V / 50 Hz, 1 NO and 1 NC auxiliary contacts: CV1BF1F0ZM511.2/ for heating circuits, d.c. supply 800 V - 150 A - 2 NO poles - Control circuit 48 V c , 1 NO + 1 NO On-delay auxiliary contacts: CV3BG2W0ZED10J12345678910Other versions: please consult our Customer Care Centre.5/11


TeSysGV2-ME, GV2-PThermal-magnetic circuit-breakers0.06…15 kW123456789Thermal-magnetic circuit-breakers GV2-ME and GV2-P for connection by screw clamp terminalsGV2-ME with pushbutton control, GV2-P control by rotary knobStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range Magnetic Reference400/415 V 500 V 690 V of thermal trippingP Icu Ics (1) P Icu Ics (1) P Icu Ics (1) trips currentkW kA kW kA kW kA A A (d ± 20%)- - - - - - - - - 0.1…0.16 1.5 GV2ME01 GV2P010.06 - - - - - - 0.16…0.25 2.4 GV2ME02 GV2P020.09 - - - - - - 0.25…0.40 5 GV2ME03 GV2P030.12 - - - 0.37 0.40…0.63 8 GV2ME04 GV2P040.18 - - - - - - 0.40…0.63 8 GV2ME04 GV2P040.25 - - - 0.55 - 0.63…1 13 GV2ME05 GV2P050.37 0.37 - - - 1…1.6 22.5 GV2ME06 GV2P060.55 0.55 0.75 1…1.6 22.5 GV2ME06 GV2P06- - - 0.75 1.1 1…1.6 22.5 GV2ME06 GV2P060.75 1.1 1.5 3 75 1.6…2.5 33.5 GV2ME070.75 1.1 1.5 8 100 1.6…2.5 33.5 GV2P071.1 1.5 2.2 3 75 2.5…4 51 GV2ME081.1 1.5 2.2 8 100 2.5…4 51 GV2P081.5 2.2 3 3 75 2.5…4 51 GV2ME081.5 2.2 3 3 100 2.5…4 51 GV2P082.2 3 50 100 4 3 75 4…6.3 78 GV2ME102.2 3 4 6 100 4…6.3 78 GV2P103 4 10 100 5.5 3 75 6…10 138 GV2ME143 4 50 100 5.5 6 100 6…10 138 GV2P144 5.5 10 100 7.5 3 75 6…10 138 GV2ME144 5.5 50 100 7.5 6 100 6…10 138 GV2P145.5 15 50 7.5 6 75 9 3 75 9…14 170 GV2ME165.5 7.5 42 75 9 6 100 9…14 170 GV2P16- - - - - - 11 3 75 9…14 170 GV2ME16- - - - - - 11 6 100 9…14 170 GV2P167.5 15 50 9 6 75 15 3 75 13…18 223 GV2ME207.5 50 50 9 10 75 15 4 100 13…18 223 GV2P209 15 40 11 4 75 18.5 3 75 17…23 327 GV2ME219 50 50 11 10 75 18.5 4 100 17…23 327 GV2P2111 15 40 15 4 75 - - - 20…25 327 GV2ME22 (2)11 50 50 15 10 75 - - - 20…25 327 GV2P2215 10 50 18.5 4 75 22 3 75 24…32 416 GV2ME3215 50 50 18.5 10 75 22 4 100 24…32 416 GV2P32H > 100 kA(1) as % of Icu(2) combined with a recommended contactorThermal-magnetic circuit-breakers GV2-ME for connection by spring terminalsAdd the figure 3 to the end of the reference. Example: GV2ME22 becomes GV2ME223Thermal-magnetic circuit-breakers GV2-ME for connection by ring terminalsAdd the figure 6 to the end of the reference. Example: GV2ME32 becomes GV2ME32610TeSys extended rotary handlesThese handles are suitable for the following products GV2 -P et GV2 - L GV3-P et GV3 - L TeSys UKit IP54 black handle GV2APN01 GV3APN01 LU9APN21IP54 kit red handle and yellow front GV2APN02 GV3APN02 LU9APN22IP65 kit red handle and yellow front GV2APN04 GV3APN04 LU9APN24Common accessories GV2 / GV3, see page 5/155/12Other versions: please consult our Customer Care Centre.


TeSysGV2-L, GV2-LEMagnetic circuit-breakers0.06 to 15 kW1Magnetic circuit-breakers GV2-LE and GV2-L for connection by screw clamp terminalsGV2-LE control by rocker lever, GV2-L control by rotary knobStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Magnetic Tripping Use in association Reference400/415 V 500 V 690 V protection current with thermalP Icu Ics (1) P Icu Ics (1) P Icu Ics (1) rating d ± 20% overload relaykW kA kW kA kW kA A A0.06 - - - - - - 0.4 5 LR2K0302 GV2LE030.09 - - - - - - 0.4 5 LR2K0304 GV2LE03or LRD03GV2L030.12 - - - 0.37 0.63 8 LR2K0304 GV2LE04or LRD04GV2L040.18 - - - - - - 0.63 8 LR2K0305 GV2LE04or LRD04GV2L04- - - - - - 0.55 1 13 LR2K0305 GV2LE05or LRD05GV2L050.25 - - - - - - 1 13 LR2K0306 GV2LE05or LRD05GV2L05- - - - - - 0.75 1 13 LR2K0306 GV2LE05or LRD06GV2L050.37 0.37 - - - 1 13 LR2K0306 GV2LE05or LRD05GV2L050.55 0.55 1.1 1.6 22.5 LR2K0307 GV2LE06or LRD06GV2L06- - - 0.75 - - - 1.6 22.5 LR2K0307 GV2LE06or LRD06GV2L060.75 1.1 1.5 3 75 2.5 33.5 LR2K0308 GV2LE070.75 1.1 1.5 4 100 2.5 33.5 LRD07 GV2L071.1 - - - - - - 2.5 33.5 LR2K0308 GV2LE08or LRD08GV2L081.5 1.5 3 3 75 4 51 LR2K0310 GV2LE081.5 1.5 3 4 100 4 51 LRD08 GV2L08- - - 2.2 - - - 4 51 LR2K0312 GV2LE08or LRD08GV2L082.2 3 50 100 4 3 75 6.3 78 LR2K0312 GV2LE102.2 3 4 4 100 6.3 78 LRD10 GV2L103 4 10 100 5.5 3 75 10 138 LR2K0314 GV2LE143 4 10 100 5.5 4 100 10 138 LRD12 GV2L144 5.5 10 100 - - - 10 138 LR2K0316 GV2LE14or LRD14GV2L14- - - - - - 7.5 3 75 10 138 LRD14 GV2LE14- - - - - - 7.5 4 100 10 138 LRD14 GV2L14- - - - - - 9 3 75 14 170 LRD16 GV2LE16- - - - - - 9 4 100 14 170 LRD16 GV2L165.5 15 50 7.5 6 75 11 3 75 14 170 LR2K0321 GV2LE165.5 50 50 7.5 10 75 11 4 100 14 170 LRD16 GV2L167.5 15 50 9 6 75 15 3 75 18 223 LRD21 GV2LE207.5 50 50 9 10 75 15 4 100 18 223 LRD21 GV2L209 15 40 11 4 75 18.5 3 75 25 327 LRD22 GV2LE229 50 50 11 10 75 18.5 4 100 25 327 LRD22 GV2L2211 15 40 15 4 75 - - - 25 327 LRD22 GV2LE2211 50 50 15 10 75 - - - 25 327 LRD22 GV2L2215 10 50 18.5 4 75 22 3 75 32 416 LRD32 GV2LE3215 50 50 18.5 10 75 22 4 100 32 416 LRD32 GV2L32H > 100 kA(1) as % of IcuCommon accessories GV2 / GV3, see page 5/15Other versions: please consult our Customer Care Centre.5/132345678910


TeSysGV3-P/GV3-LCircuit-breakersThermal-magnetic 5.5…30 kWwith EverLink terminal blocks1234Thermal-magnetic circuit-breakers GV3-P for connection by EverLink terminal blocks (2)Control by rotary knobStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range Reference400/415 V 500 V 660/690 V of thermalP Icu Ics (1) P Icu Ics (1) P Icu Ics (1) tripskW kA kW kA kW kA A5.5 100 50 7.5 12 50 11 6 50 9…13 GV3P137.5 100 50 11 12 50 15 6 50 12…18 GV3P1811 100 50 15 12 50 18.5 6 50 17…25 GV3P2515 100 50 18.5 12 50 22 6 50 23…32 GV3P3218.5 50 50 22 10 50 30 5 60 30…40 GV3P4022 50 50 30 10 50 37 5 60 37…50 GV3P5030 50 50 37 10 50 45 5 60 48…65 GV3P65(1) as % of lcuThermal-magnetic circuit-breakers GV3-P for connection by ring terminalsAdd the figure 6 to the end of the reference. Example: GV3-P13 becomes GV3-P136Thermal-magnetic circuit-breakers GV3-P for connection by only 1 EverLink terminal blockAdd the figure 1 to the end of the reference. Example: GV3P65 becomes GV3P651567Magnetic 11…30 kWwith EverLink terminal blocksMagnetic circuit-breakers GV3-L for connection by EverLink terminal blocks (2)Control by rotary knobStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Associated equipment Circuit-breaker400/415 V 500 V 690 V Thermal Short-circuitP Icu Ics P Icu Ics P Icu Ics overload protectionkW kA kW kA kW kA relay Rating A Reference11 100 50 15 12 50 18.5 6 50 LRD325 25 GV3L2515 100 50 18.5 12 50 22 6 50 LRD332 32 GV3L3218.5 50 50 22 10 50 30 5 60 LRD340 40 GV3L4022 50 50 30 10 50 45 5 60 LRD350 50 GV3L5030 50 50 37 10 50 45 5 60 LRD365 65 GV3L658Magnetic circuit-breakers GV3-L for connection by ring terminalsAdd the figure 6 to the end of the reference. Example: GV3-L25 becomes GV3-L256Magnetic circuit-breakers GV3-L for connection by only 1 EverLink terminal blockAdd the figure 1 to the end of the reference. Example: GV3L65 becomes GV3L651(2) 4 mm BTR screwAdd-on blocks and accessories (3)9Add-on blocks (front)Fault signalling contact + instantaneous auxiliary contactContact type NO (fault) + NC NO (fault) + NOReferences (4) GV-AED011 GV-AED10110Accessories Cover BusbarsTypeIP20 for lug IP20 for lug “Wide spacing” Set of 3-pole Set of 3-pole “S” form for sidetype terminalstype terminalsUL 508 type E 115 A busbars 115 A busbarsfor 2for 3by side mountedwhen used withcontactorcircuit-breakers circuit-breakers circuit-breaker/contactorReferences LAD96570 LAD96575 GV3G66 GV3G264 GV3G364 GV3S(3) Common add-on blocks and accessories GV2 / GV3, see page 5/15(4) For spring terminal version add 3 to the end of the reference. Example: GV-AED011 becomes GV-AED01135/14Other versions: please consult our Customer Care Centre.


TeSysGV2/GV3Circuit-breakersAccessories1(TeSys rotating handles)Combination block GV2For mounting on LC1-K or LP1-K LC1-D09…D38 LAD-31 and LC1-D09…D38GV2AF01 GV2AF3 GV2AF4Sets of 3-pole busbars GV263 A Pitch 45 mm 54 mm 72 mmNumber of tap-offs 2 GV2G245 GV2G254 GV2G2723 GV2G345 GV2G3544 GV2G445 GV2G454 GV2G4725 GV2G554Protective end cover GV2For unused busbar outletsGV1G10Terminal blocks GV2For supply to one or more GV2-G busbar sets connection from the top can be fitted with current limiter GV1-L3 (GV2-ME and GV2-P)GV1G09GV1G05Padlockable external operator for GV2 and GV3 (150 to 290 mm)Padlocking In “On” and “Off” position In “Off” positionHandle black redLegend plate blue yellowIP 54 For GV2-ME/P/L GV2AP01 GV2AP02For GV2-LE GV2AP03 –For GV3-P/L GV3AP01 GV3AP022345TeSys rotating handles for GV2-P GV3-PKit IP54 black handle GV2APN01 GV3APN01IP54 kit red/yellow handle GV2APN02 GV3APN02IP65 kit red/yellow handle GV2APN04 GV3APN04Contact blocks common to GV2 / GV3NO + NC NO + NC NO + NO (fault) + NC (fault) + NO CO commonInstantaneous auxiliary contactsMounting front GVAE1 GVAE11 GVAE20LH side GVAN11 GVAN20Fault signalling contact + instantaneous auxiliary contactLH side NO (fault) GVAD1001 GVAD1010NC (fault) GVAD0101 GVAD0110Short-circuit signalling contactLH sideElectric trips for GV2 and GV3 : undervoltage or shunt (1)Side mounting (1 block on RH side of circuit-breaker) 50 Hz 60 HzVoltage 24 V GVA•025 GVA•02648 V GVA•055 GVA•056100 V GVA•107100…110 V GVA•107110…115 V GVA•115 GVA•116120…127 V GVA•125127 V GVA•115200 V GVA•207200…220 V GVA•207220…240 V GVA•225 GVA•226380…400 V GVA•385 GVA•386415…440 V GVA•415415 V GVA•416Padlocking deviceFor use with up to 4 padlocks (padlocks not supplied) Ø 6 mm shank max GV2V03(1) Undervoltage trips: replace the • with U, shunt trips: replace the • with SpointGVAM11Other versions: please consult our Customer Care Centre.5/15678910


TeSysGV7-RThermal-magnetic circuit-breakers0.75…90 kW1234567Thermal-magnetic circuit-breakers GV7-R for connection by screw clamp terminalsControl by rocker leverStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range Reference400/415 V 500 V 660/690 V of thermalP Icu Ics (1) P Icu Ics (1) P Icu Ics (1) tripskW kA kW kA kW kA A7.5 25 100 9 18 100 11 8 100 12…20 GV7RE209 25 100 11 18 100 15 8 1007.5 70 100 9 50 100 11 10 100 12…20 GV7RS209 70 100 11 50 100 15 10 1009 25 100 11 18 100 15 8 100 15…25 GV7RE2511 25 100 15 18 100 18.5 8 1009 70 100 11 50 100 15 10 100 15…25 GV7RS2511 70 50 15 50 100 18.5 10 10018.5 25 100 18.5 18 100 22 8 100 25…40 GV7RE4022 18 10018.5 70 100 18.5 50 100 22 10 100 25…40 GV7RS4022 25 100 30 18 100 30 8 100 30…50 GV7RE5037 25 100 45 18 100 55 8 100 48…80 GV7RE8055 18 10037 70 100 45 50 100 55 10 100 48…80 GV7RS8055 50 10045 25 100 - 18 100 75 8 100 60…100 GV7RE10045 70 100 - 50 100 75 10 100 60…100 GV7RS10055 35 100 75 30 100 90 8 100 90…150 GV7RE15075 70 100 90 30 100 110 8 10055 70 100 75 50 100 90 10 100 90…150 GV7RS15075 70 100 90 50 100 110 10 10090 35 100 110 30 100 160 8 100 132…220 GV7RE220110 35 100 132 30 100 200 8 100160 30 10090 70 100 110 50 100 160 10 100 132…220 GV7RS220(1) as % of Icu89105/16Other versions: please consult our Customer Care Centre.


1Add-on blocksContact blocksAuxiliary contactsContact typeCOGV7AE11Thermal or magnetic fault discriminationz 24…48 V or c 24…72 Vz 110…240 VGV7AD111GV7AD112Electric tripsVoltage 50/60 Hz 48 V 110… 130 V 200… 240 V 380…440 V50 Hz 525 VUndervoltage trip (1) GV7AU055 GV7AU107 GV7AU207 GV7AU387 GV7AU525Shunt trip (1) GV7AS055 GV7AS107 GV7AS207 GV7AS387 GV7AS525(1) For mounting of a GV7-AD or a GV7-AU or AS234AccessoriesTerminal shields IP 405Supplied with sealing accessoryGV7AC01Phase barriersSafety accessoriesGV7AC04used when fitting of shields is impossibleInsulating screensEnsure insulation betweenGV7AC05the connections and the backplateKit for combination with contactorAllowing link between the circuit-breaker and the contactor LC1-F115 to F185 LC1-F225 and F26 LC1-D115 and D150GV7AC06 GV7AC07 GV7AC08Rotary handlesHandle black redLegend plate black yellow direct IP 40 GV7AP03 GV7AP04 extended IP 55 GV7AP01 GV7AP02Conversion accessoryfor mounting on enclosure door IP 43 GV7AP05Locking deviceFor circuit-breaker not fitted with a rotary handleGV7V015678910Other versions: please consult our Customer Care Centre.5/17


TeSysGV3-METhermal-magnetic circuit-breakers37 kW123Thermal-magnetic circuit-breakers GV3-ME for connection by screw clamp terminalsPushbutton controlStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range Reference400/415 V 500 V 660/690 V of thermalP Icu Ics (1) P Icu Ics (1) P Icu Ics (1) tripskW kA kW kA kW kA A37 15 50 45 4 100 55 2 100 56…80 GV3ME80(1) as % of Icu4567Add-on blocks for GV3-MEContact blocksInstantaneous auxiliary contacts (1 per breaker)Normal early break type contacts NC + NO NO + NO NC + NO + NO NO + NO + NO NO + NO (1) NC + NO (1)GV3A01 GV3A02 GV3A03 GV3A05 GV3A06 GV3A07Fault signalling contactNormal early break type contacts NC NOGV3A08GV3A09Electric tripsVoltage 50 Hz 110, 120, 127 V 220, 240 V 380, 415 V60 Hz 120, 127 V 277 V 440, 480 VUndervoltage trip GV3B11 GV3B22 GV3B38Shunt trip GV3D11 GV3D22 GV3D38Padlocking deviceStart button (for bare device)GV1V02(1) + 2 volt free terminals89105/18Other versions: please consult our Customer Care Centre.


TeSysGK3-EFMagnetic circuit-breakers37 kW1Magnetic circuit-breakers GK3-EF for connection by screw clamp terminalsControl by rotary knobStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Associated equipment Circuit-breaker400/415 V 500 V 690 V Thermal Short-circuitP Icu Ics P Icu Ics P Icu Ics overload relay protectionkW kA kW kA kW kA min. size Rating A Reference37 35 25 45 15 30 - - - LRD-3363 80 GK3EF80234Add-on blocks for GK3Contact blocksContact type NO NO + NO NC + NO NC NOOn-Off signalling contacts GK2AX10 GK2AX20 GK2AX50and “Control circuit test” function (1 or 2 blocks per device)mounted on RH side of GK3-EFInstantaneous fault signalling contacts GK2AX12 GK2AX22 GK2AX52(1 or 2 blocks per device) mounted on LH side of GK3-EFFault signalling contact (1) GV3A08 GV3A09(1) 1 trip OR 1 fault signalling contact to be fitted inside the circuit-breaker.5678Accessories for GK3Padlocking devicefor padlocking the operator with up to 3 padlocks (padlocks not supplied)External operatorfor mounting on enclosure door.Red Ø 40 pushbutton on yellow plate, can be locked inposition O by means of up to 3 padlocks with door locked inposition I, and door locked in position O when padlockedGK3AV01GK3AP03910Other versions: please consult our Customer Care Centre.5/19


TeSys DFFuse carriers0…125 A1TypeFuse carriers without “blown fuse” indicator23Rated insulation voltage (Ui) 500 V 690 VFuse size 8.5 x 31.5 mm 10 x 38 mm 14 x 51 mm 22 x 58 mmConventional thermal current (Ith) 25 A 32 A 50 A 125 AReferences Number of poles 1P DF81 DF101 DF141 DF221N DF10N DF10N DF14N DF22N1P+N DF81N DF101N DF141N DF221N2P DF82 DF102 DF142 DF2223P DF83 DF103 DF143C DF223C3P+N DF83N DF103N DF143NC DF223NC45TypeFuse carriers with “blown fuse” indicator67Rated insulation voltage (Ui) 500 V 690 VFuse size 8.5 x 31.5 mm 10 x 38 mm 14 x 51 mm 22 x 58 mmConventional thermal current (Ith) 25 A 32 A 50 A 125 AReferences Number of poles 1P DF81V DF101V DF141V DF221V1P + N DF81NV DF10NV DF14NV DF22NV2P DF82V DF102V DF142V DF222V3P DF83V DF103V DF143VC DF223VC3P + N DF83NV DF103NV DF143NVC DF223NVC8Accessories9TypeAuxiliary early break and blown fuse signalling contactsFuse carrier to be equipped DF14 DF22Fuse size 14 x 51 mm 22 x 58 mmNumber of poles 3P or 3P + N 3P or 3P + NNumber of contacts 1 2 1 2References DF14AM1 DF14AM2 DF22AM1 DF22AM210TypeFuse carrier assembly kitsFuse carrier to be assembled DF8 DF10 DF14 DF22Fuse size 8.5 x 31.5 mm 10 x 38 mm 14 x 51 mm 22 x 58 mmKit contents 1 pin, 2 clips 1 pin, 3 clipsReferences DF10AP DF14AP DF22AP5/20Other versions: please consult our Customer Care Centre.


TeSysLS1, GK1Fuse carriers0…125 A1Type3-pole fuse carriersRated insulation voltage (Ui)690 VRating 25 A 32 A 50 A 125 AFuse size 10 x 38 10 x 38 14 x 51 22 x 58Connection Spring terminals Screw clamp terminals or connectorsSingle-phase protection device Without Without Without With Without WithNumber of early break contacts – – 1 1Reference LS1D323 LS1D32 GK1K GK1EV GK1FK GK1FVNumber of early break contacts 2 2Reference GK1ES GK1EW GK1FS GK1FW2345Type4-pole fuse carriersRated insulation voltage (Ui)690 VRating 32 A 50 A 125 AFuse size 10 x 38 14 x 51 22 x 58ConnectionScrew clamp terminals or connectorsSingle-phase protection device Without Without With Without WithNumber of early break contacts – 1 1Reference LS1D32 + LA8D324 GK1EM GK1EY GK1FM GK1FYNumber of early break contacts 2 2Reference GK1ET GK1EX GK1FT GK1FX678910Other versions: please consult our Customer Care Centre.5/21


TeSysLS1, GK1Fuse carriersAccessories1TypeEarly break auxiliary contact blocks2Fuse carrier rating 32 A 25 AFor use with fuse carrier LS1D32 LS1D323Contact type NO + NC NO + NO NO + NC NO + NOReferences GVAE11 GVAE20 GVAE113 GVAE20334TypeDirect operator handleFuse carrier rating 125 A 32, 50, 125 AFor mounting on RH side LH side FrontReferences GK1AP07 GK1AP08 Fitted as standard56TypeExternal operator handleFuse carrier rating 32 A 50 A 125 AFor mounting on RH side LH side RH side LH side RH side LH sideReferences LS1D32005 LS1D32006 GK1AP05 GK1AP06 GK1AP07 GK1AP087TypePadlocking devices8Fuse carrier rating 32 A 50 ANumber of poles 3 or 4 3 4Single-phase protection device Without Without With Without WithReferences Integrated GK1AV07 GK1AV08 GK1AV08 GK1AV09910TypeTubular linkFuse carrier rating 32 A 50 A 125 AReferences DK1CB92 DK1EB92 DK1FA95/22Other versions: please consult our Customer Care Centre.


TeSys GSSwitch-disconnector-fusesHandles1TypeIP65 handles for external front-mounted operatorsSwitch rating 32…63 A 100…400 A 630…800 A 1250 AReferences Black/grey GS2AH510 (1) GS2AH530 (1) GS2AH550 GS2AH570Red/yellow GS2AH520 (1) GS2AH540 (1) GS2AH560 GS2AH580(1) For external front operators with Test facility, insert the letter T in the reference. Example: GS2AH510 becomes GS2AHT5102Type IP65 handles for external RH side-mounted operators (2)Switch rating 32…63 A 100…400 A 630…1250 AReferences Black/grey GS2AH210 GS2AH230 GS2AH250Red/yellow GS2AH220 GS2AH240 GS2AH260(2) For external LH side-mounted operators, replace the number 2 in the reference by 3. Example: GS2AH210 becomes GS2AH310TypeShafts for external operators34Switch rating 32 A 50…400 A 630…1250 AReferences Length of shaft 200 mm GS2AE82 GS2AE22 GS2AE52320 mm GS2AE8 GS2AE2 GS2AE5400 mm GS2AE81 GS2AE21 GS2AE51567TypeHandles for direct operatorsSwitch rating 32 A 50 and 63 A 100…400 A 630 and 800 A 1250 AType of operator Front RH side RH side Front FrontReferences GS1AH103 GS1AH01 GS1AH02 GS2AH104 GS2AH1058910Other versions: please consult our Customer Care Centre.5/23


TeSys GSSwitch-disconnector-fuses32…1250 A12345TypeSwitch-disconnector-fuse switch bodies for use with NF C or DIN fusesHandle to be ordered separately (see previous page)Rated insulation voltage (Ui)690 VConventional thermal current (Ith) 32 A 50 A 63 A 100 AFuse size 10 x 38 14 x 51 Size 00C (1) 22 x 58External front-mounted and 3-pole GS1DD3 GS2F3 GS2G3 GS2J3RH side-mounted operator 4-pole GS1DD4 (2) GS2F4 GS2G4 GS2J4External LH side-mounted 3-pole GS1DD3 GS2FG3 GS2GG3 GS2JG3operator 4-pole GS1DD4 (2) GS2FG4 GS2GG4 GS2JG4Direct RH side-mounted 3-pole GS1DD3 (3) GS1FD3 GS1GD3 GS1JD3operator 4-pole GS1DD4 (2) (3) GS1FD4 GS1GD4 GS1JD4(1) Compact fuse for German market(2) 3-pole + switched neutral(3) Direct front-mounted operatorTypeSwitch-disconnector-fuse switch bodies for use with BS fusesHandle to be ordered separately (see previous page)Rated insulation voltage (Ui)690 VConventional thermal current (Ith) 32 A 32 A 63 A 100 AFuse size A1 A1 A2-A3 A4 (Ø ≤ 31 mm)External front-mounted and 3-pole GS1DDB3 GS2DB3 GS2GB3 GS2JB3RH side-mounted operator 4-pole GS1DDB4 (2) GS2DB4 GS2GB4 GS2JB46Accessories78910TypeAuxiliary contactsEarly break and/or O, I and Test signallingO and I signallingSwitch rating 32…1250 A 50…1250 ANumber of contacts 1 NO 1 NC 1 NO + NC 2 NO + 2 NCOperator external front-mounted or RH side-mounted GS1AM110 GS1AM101 GS1AN11 GS1AN22external LH side-mounted GS1AM110 GS1AM101 GS1AN11G GS1AN22Gdirect RH side-mounted – – GS1AN11 GS1AN22direct front-mounted – – – –TypeAuxiliary “blown fuse” signalling contacts for use with NF C and DIN fusesNumber of contacts1 NO/NCSwitch rating 50 A 100 and 125 A 160 A 250 and 400 AFuse size 14 x 51 22 x 58 Size 0 Size 1 and Size 2References 3-pole GS1AF1 GS1AF23 GS1AF33 GS1AF434-pole GS1AF1 GS1AF24 GS1AF34 GS1AF445/24Other versions: please consult our Customer Care Centre.


1125 A 160 A 250 A 400 A 630 A 1250 A22 x 58 Size 00 Size 00 Size 0 Size 1 Size 2 Size 3 Size 4GS2K3 GS2KK3 GS2LL3 GS2L3 GS2N3 GS2QQ3 GS2S3 GS2V3GS2K4 GS2KK4 GS2LL4 GS2L4 GS2N4 GS2QQ4 GS2S4 GS2V4GS2KG3 GS2KKG3 GS2LLG3 GS2LG3 GS2NG3 GS2QQG3 GS2SG3 GS2VG3GS2KG4 GS2KKG4 GS2LLG4 GS2LG4 GS2NG4 GS2QQG4 GS2SG4 GS2VG4GS1KD3 GS1KKD3 GS1LLD3 GS1LD3 GS1ND3 GS1QQD3 GS2S3 (3) GS2V3 (3)GS1KD4 GS1KKD4 GS1LLD4 GS1LD4 GS1ND4 GS1QQD4 GS2S4 (3) GS2V4 (3)234160 A 200 A 250 A 315 A 400 A 630 A 800 A 1250 AA4 B1-B2 B1-B2 B1…B3 B1…B3 B1…B4 C1-C2 C1…C3 D1GS2LLB3 GS2LB3 GS2MMB3 GS2NB3 GS2PPB3 GS2QQB3 GS2SB3 GS2TB3 GS2VB3GS2LLB4 GS2LB4 GS2MMB4 GS2NB4 GS2PPB4 GS2QQB4 GS2SB4 GS2TB4 GS2VB45678O, I and Test signalling Early break and O and I signalling50…400 A 32 A 50…400 A1 NO + NC 2 NO + 2 NC 1 NO/NC 2 NO/NC 1 NO/NC 2 NO/NCGS1ANT11 GS1ANT22 – – – –– – – – – –– – – – GS1AM1 GS1AM2– – GS1AM111 GS1AM211 – –92 nd NO/NC630 A 1250 A 50…1250 ASize 3 Size 4 –GS2AF63 GS2AF73 GS1AFGS2AF64 GS2AF74 GS1AF10Other versions: please consult our Customer Care Centre.5/25


TeSys KThermal overload relays0.11…11.5 A123456789Thermal overload relays, TeSys Kadjustable from 0.11 to 12 AConnection by screw clamp terminals, direct mounting on contactors LC1-K, manual or automatic resetRelay setting range Fuses to be used with selected relay ReferenceClass 10A aM gG BS880.11…0.16 A 0.25 A 0.5 A - LR2K03010.16…0.23 A 0.25 A 0.5 A - LR2K03020.23…0.36 A 0.5 A 1 A - LR2K03030.36…0.54 A 1 A 1.6 A - LR2K03040.54…0.8 A 1 A 2 A - LR2K03050.8…1.2 A 2 A 4 A 6 A LR2K03061.2…1.8 A 2 A 6 A 6 A LR2K03071.8…2.6 A 2 A 6 A 10 A LR2K03082.6…3.7 A 4 A 10 A 16 A LR2K03103.7…5.5 A 6 A 16 A 16 A LR2K03125.5…8 A 8 A 20 A 20 A LR2K03148…11.5 A 10 A 25 A 20 A LR2K0316Thermal overload relays for use on class 10A unbalanced loads: for above references LR2-K0305 to LR2-K0316 only, replace the prefix LR2 with LR7.Example: LR7-K0310.AccessoriesPrewiring kitAllowing direct connection of the NC contactFor use onof relay LRD-01…35 or LR3-D01… D35 to the contactor LC1D09…D18 LAD7C1LC1D25…D38LAD7C2Terminal blocks (1)For clip-on mounting on 35 mm mounting rail (AM1-DP200) LRD01…35 and LR3D01…D35 LAD7B10or screw fixing LRD3•••, LR3D3•••, LRD35•• LA7D3064 (2)For independent mounting of the relay LR2K•••• LA7K0064EverLink Terminal blocksSeparate terminal block LRD313… LRD365 LAD9R3Terminal block adapterFor mounting a relay beneath an LC1-D115 or D150 contactor LRD3•••, LR3D3•••, LRD35•• LA7D3058Stop or electrical resetRemote (3) LRD01…35 and LR3D01…D35 LAD703• (4)Tripping or electrical reset deviceRemote (3) All relays except LRD01…35 and LR3D01…D35 LA7D03• (4)(1) Terminal blocks are supplied with terminals protected against direct finger contact and screws in the open “ready-to-tighten” position.(2) To order a terminal block for connection by lug-clamps, the reference becomes LA7-D30646.(3) The time for which the coil of remote tripping or electrical resetting device LA7-D03 or LAD-703 can remain energised depends on its rest time: 1 s pulse duration with 9 s resttime; maximum pulse duration of 20 s with a rest time of 300 s. Minimum pulse time 200 ms.(4) Reference to be completed by adding the code indicating the control circuit voltage.10Standard control circuit voltagesa supplyVolts 12 24 48 96 110 220/230 380/400 415/44050/60 Hz. Consumption, inrush and sealed < 100 VA - B E - F M Q Nc supplyConsumption, inrush and sealed < 100 W J B E DD F M - -5/26Other versions: please consult our Customer Care Centre.


TeSys DThermal overload relays0.1…140 A1Thermal overload relays, TeSys Dadjustable from 0.1 to 140 ACompensated relays with manual or automatic reset, with relay trip indicator, for a.c. or d.c.Relay setting range Fuses to be used with selected relay With contactor ReferenceConnection by screw clamp terminals or connectors aM gG BS88Class 10A 0.10…0.16 A 0.25 A 2 A - LC1D09…D38 LRD01 (1)0.16…0.25 A 0.5 A 2 A - LC1D09…D38 LRD02 (1)0.25…0.40 A 1 A 2 A - LC1D09…D38 LRD03 (1)0.40…0.63 A 1 A 1.6 A - LC1D09…D38 LRD04 (1)0.63…1 A 2 A 4 A - LC1D09…D38 LRD05 (1)1…1.7 A 2 A 4 A 6 A LC1D09…D38 LRD06 (1)1.6…2.5 A 4 A 6 A 10 A LC1D09…D38 LRD07 (1)2.5…4 A 6 A 10 A 16 A LC1D09…D38 LRD08 (1)4…6 A 8 A 16 A 16 A LC1D09…D38 LRD10 (1)5.5…8 A 12 A 20 A 20 A LC1D09…D38 LRD12 (1)7…10 A 12 A 20 A 20 A LC1D09…D38 LRD14 (1)9…13 A 16 A 25 A 25 A LC1D12…D38 LRD16 (1)12…18 A 20 A 35 A 32 A LC1D18…D38 LRD21 (1)16…24 A 25 A 50 A 50 A LC1D25…D38 LRD22 (1)23…32 A 40 A 63 A 63 A LC1D25…D38 LRD32 (1)30…38 A 50 A 80 A 80 A LC1D32 and D38 LRD35 (1)55…70 A 80 A 125 A 125 A D50…D95 LRD3361 (1)63…80 A 80 A 125 A 125 A D65…D95 LRD3363 (1)80…104 A 100 A 160 A 160 A D80 and D95 LRD3365 (1)80…104 A 125 A 200 A 160 A D115 and D150 LRD4365 (1)95…120 A 125 A 200 A 200 A D115 and D150 LRD4367 (1)110…140 A 160 A 250 A 200 A D150 LRD4369 (1)80…104 A 100 A 160 A 160 A Independent mtg. LRD33656 (1)95…120 A 125 A 200 A 200 A Independent mtg. LRD33676 (1)110…140 A 160 A 250 A 200 A Independent mtg. LRD33696 (1)Class 20 6 A 10 A 16 A LC1D09…D32 LRD1508 (1)4…6 A 8 A 16 A 16 A LC1D09…D32 LRD1510 (1)5.5…8 A 12 A 20 A 20 A LC1D09…D32 LRD1512 (1)7…10 A 16 A 20 A 25 A LC1D09…D32 LRD1514 (1)9…13 A 16 A 25 A 25 A LC1D12…D32 LRD1516 (1)12…18 A 25 A 35 A 40 A LC1D18…D32 LRD1521 (1)17…25 A 32 A 50 A 50 A LC1D25 and D32 LRD1522 (1)23…28 A 40 A 63 A 63 A LC1D25 and D32 LRD1530 (1)25…32 A 40 A 63 A 63 A LC1D25 and D32 LRD1532 (1)55…70 A 100 A 125 A 125 A D65…D95 LR2D3561 (1)63…80 A 100 A 160 A 125 A D80 and D95 LR2D3563 (1)Connection by EverLink terminal blocks, with BTR screwsClass 10A 9…13 A 16 A 25 A 25 A LC1D40A…D65A LRD313 (2)12…18 A 20 A 32 A 35 A LC1D40A…D65A LRD318 (2)17…25 A 25 A 50 A 50 A LC1D40A…D65A LRD325 (2)23…32 A 40 A 63 A 63 A LC1D40A…D65A LRD332 (2)30…40 A 40 A 80 A 80 A LC1D40A…D65A LRD340 (2)37…50 A 63 A 100 A 100 A LC1D40A…D65A LRD350 (2)48…65 A 63 A 100 A 100 A LC1D40A…D65A LRD365 (2)Class 20 9…13 A 20 A 32 A 35 A LC1D40A…D65A LRD313L (2)12…18 A 25 A 40 A 40 A LC1D40A…D65A LRD318L (2)17…25 A 32 A 50 A 50 A LC1D40A…D65A LRD325L (2)23…32 A 40 A 63 A 63 A LC1D40A…D65A LRD332L (2)30…40 A 50 A 80 A 80 A LC1D40A…D65A LRD340L (2)37…50 A 63 A 100 A 100 A LC1D40A…D65A LRD350L (2)48…65 A 80 A 125 A 125 A LC1D40A…D65A LRD365L (2)Class 10A with connection by lug-clamps:Thermal overload relays for use with unbalanced loads Class 10ASelect overload relay with screw clamp terminals or connectors from the table above and add with connection by screw clamp terminals and lug-clamp terminals:one of the following suffixes:In the reference selected above, change LRD(except LRD4ppp) to LR3Db figure 6 for relays LRD01 to LRD35 and LRD313 to LRD365.b A66 for relays LRD3361 to LRD3365.Relays LRD43 are suitable as standard, for use with lug-clamps.Example: LRD01 becomes LR3D 01Example with EverLink terminals: LRD340 becomes LR3D 340Example with lug-clamp terminals: LRD3406 becomes LR3D 3406(1) For independent mounting on a DIN rail, order an EverLink LAD7B106 terminal block. (2) For independent mtg. on a DIN rail, order an EverLink LAD96560 terminal block.2345678910Other versions: please consult our Customer Care Centre.5/27


TeSysLR9Electronic thermal overload relays60…630 A12For use with contactor LC1-D LC1-FMotor current 60…150 A 30…630 ABasic reference, to be completed LR9D LR9F34567Relay setting range Fuse to be used with selected relay For mounting Compensated and differential With alarmbeneath contactor LC1-aM gG Class 10 Class 20 Class 10 or 2060…100 100 160 D115 and D150 LR9D5367 LR9D556790…150 160 250 D115 and D150 LR9D5369 LR9F556930…50 50 80 F115…F185 LR9F5357 LR9F5557 LR9F5748…80 80 125 F115…F185 LR9F5363 LR9F5563 LR9F6360…100 100 200 F115…F185 LR9F5367 LR9F5567 LR9F6790…150 160 250 F115…F185 LR9F5369 LR9F5569 LR9F69132…220 250 315 F185…F400 LR9F5371 LR9F5571 LR9F71200…330 400 500 F225…F500 LR9F7375 LR9F7575 LR9F75300…500 500 800 F225…F500 LR9F7379 LR9F7579 LR9F79380…630 630 800 F400…F630 and F800 LR9F7381 LR9F7581 LR9F818910AccessoriesRemote controlFunction Reset Stop and/or ResetElectrical reset (1) LA7D03• (2)Reset by flexible cable (length 0.5 m)LA7D305Adapter for door interlock mechanismLA7D1020Operating head for pushbuttonSpring return ZA2BL639 ZA2BL432Rod with snap-off endAdjustable from 17 to 120 mmInsulated terminal blocksZA2BZ13For relays LR9-F5•57, F5•63, F5•67, F5•69, F57, F63, F67 and F69 Set of 2 blocksLA9F103(1) The time for which the coil of remote electrical reset device LA7-D03 can remain energised depends on its rest time: 1 s pulse with 9 s rest time; 5 s pulse duration with 30 srest time; 10 s pulse duration with 90 s rest time: maximum pulse duration 20 s with rest time of 300 s. Minimum pulse time: 200 ms.(2) Reference to be completed by adding the coil voltage code, see page 5/275/28Other versions: please consult our Customer Care Centre.


TeSysLR/LTElectronic overcurrent relays0.3…38 A1Relay typeElectronic overcurrent relaysTeSys LR97DRelay setting range 0.3…1.5 A 1.2…7 A 5…25 A 20…38 AFor use with contactor LC1D09…D38 LC1D25…D38References 200… 240 VAC LR97D015M7 LR97D07M7 LR97D025M7 LR97D038M7100… 120 VAC LR97D015F7 LR97D07F7 LR97D025F7 LR97D038F724 VAC/DC LR97D015B LR97D07B LR97D025B LR97D038B48 VAC/DC LR97D015E LR97D07E LR97D025E LR97D038E0.5…60 A234Relay typeElectronic overcurrent relaysTeSys LT47 with manual resetRelay setting range 0.5…6 A 3…30 A 5…60 AReferences 200… 240 VAC LT4706M7S LT47D30M7S LT4760M7S100… 120 VAC LT47D06F7S LT47D30F7S LT4760F7S24 VAC/DC LT47D06BS LT47D30BS LT4760BS48 VAC/DC LT47D06ES LT47D30ES LT4760ES567Relay typeElectronic overcurrent relaysTeSys LT47 with automatic resetRelay setting range 0.5…6 A 3…30 A 5…60 AReferences 200… 240 VAC LT4706M7A LT47D30M7A LT4760M7A100… 120 VAC LT47D06F7A LT47D30F7A LT4760F7A24 VAC/DC LT47D06BA LT47D30BA LT4760BA48 VAC/DC LT47D06EA LT47D30EA LT4760EAAccessories: please consult your Schneider Electric agency.8910Other versions: please consult our Customer Care Centre.5/29


TeSys TMotor management systemControllers1Type of fieldbus Ethernet Modbus Profibus DP2Supply voltage 24 VDC 100…240 VAC 24 VDC 100…240 VAC 24 VDC 100…240 VACReferences Current range 0.4…8 A LTMR08EBD LTMR08EFM LTMR08MBD LTMR08MFM LTMR08PBD LTMR08PFM1.35…27 A LTMR27EBD LTMR27EFM LTMR27MBD LTMR27MFM LTMR27PBD LTMR27PFM5…100 A LTMR100EBD LTMR100EFM LTMR100MBD LTMR100MFM LTMR100PBD LTMR100PFM34Type of fieldbus CANopen DeviceNet5Supply voltage 24 VDC 100…240 VAC 24 VDC 100…240 VACReferences Current range 0.4…8 A LTMR08CBD LTMR08CFM LTMR08DBD LTMR08DFM1.35…27 A LTMR27CBD LTMR27CFM LTMR27DBD LTMR27DFM5…100 A LTMR100CBD LTMR100CFM LTMR100DBD LTMR100DFM6Extension module78Type of moduleExtension4 additional inputs + voltage measuringEthernet external portModbus RTU / Modbus TCP/IPInputs voltage 24 VDC 100…240 VAC 24 VDCReferences LTMEV40BD LTMEV40FM TCSEQM113M13MControl unit910Type of terminalSupply voltageReferenceCompact display24 VDCLTMCU5/30Other versions: please consult our Customer Care Centre.


TeSys TMotor management systemCurrent transformers1Type of transformerExternalOperational current primary 100 A 200 A 400 A 800 Asecondary1 AReferences LT6CT1001 LT6CT2001 LT6CT4001 LT6CT80012Earth fault toroidsType of toroid Closed Split3Maximum current 65 A 85 A 160 A 250 A 400 A 630 A 85 A 250 AInternal diameter Ø 30 Ø 50 Ø 80 Ø 120 Ø 200 Ø 300 Ø 46 Ø 110References TA30 PA50 IA80 MA120 SA200 GA300 POA GOAPTC thermistor probeType of probeTripleOperating temperature 90°C 110°C 120°C 130°C 140°C 150°C 160°C 170°CReferences DA1TT090 DA1TT110 DA1TT120 DA1TT130 DA1TT140 DA1TT150 DA1TT160 DA1TT17045Accessories (1)6Type of accessoryConnecting cableController / Extension moduleLength of cable 0.04 m 0.3 m 1 mReferences LTMCC004 LU9R03 LU9R10789Type of accessoryConnecting cableController/ DisplayConnection kitPC serial portLength of cable 1 m 3 m 5 m –References VW3A1104R10 VW3A1104R30 VW3A1104R50 VW3A8106(1) For other connection accessories, see www.schneider-electric.com10Other versions: please consult our Customer Care Centre.5/31


TeSysLT3, LT6Electronic protection relays for usewith PTC thermistor probes0…800 A1Relay typePTC thermistor probes2For use with contactor LC1-D or LC1-F LC1-D or LC1-FMotor current No limit 1…5 ABasic reference, to be completed LT3S LT6P0M0•5FM3Protection unit456Typewith automatic reset with thermistor short-circuit detectionwithout fault memoryConnection Voltage Output contact Referenceby cage connectors a 50/60 Hz 115 V NC LT3SE00F230 V NC LT3SE00Mc 24 V NC LT3SE00FOn front panel: fault and voltage signalling indicatora 50/60 Hz 115/230 V NC + NO LT3SA00Mc 24/48 V NC + NO LT3SA00EDa 50/60 Hz or c 24…230 V 2 CO LT3SA00MWwith fault memoryOn front panel: fault and voltage signalling indicator, Test and Reset button7a 50/60 Hz 400 V NC + NO LT3SM00V24/48 V NC + NO LT3SM00E115/230 V NC + NO LT3SM00Mc 24/48 V NC + NO LT3SM00EDa 50/60 Hz or c 24…230 V 2 CO LT3SM00MW8AccessoriesTypePTC thermistor probes for LT3 relays9Normal operating temperature (NOT) 90 °C 110 °C 120 °C 130 °C 140 °C 150 °C 160 °C 170 °CIntegrated triple probes DA1TT090 DA1TT110 DA1TT120 DA1TT130 DA1TT140 DA1TT150 DA1TT160 DA1TT170Normal operating temperature (NOT) 60 °C 70 °C 80 °C 90 °C 100 °CSurface probes DA1TS060 DA1TS070 DA1TS080 DA1TS090 DA1TS100105/32Other versions: please consult our Customer Care Centre.


TeSysVarioSwitch disconnectors12…175 A1/L13/L25/L312/T14/T26/T32/T14/T26/T3TypeMini-Vario for standard applicationsDoor mountingColour: Handle / Front plate Red / Yellow Black / Black Red / YellowFront plate dimensions (mm) 60 x 60 60 x 60Fixing Ø 22.5 mm Ø 22.5 mmDegree of protection IP 20 IP 20Rated insulation voltage (Ui) 690 V 690 VThermal current in open air (Ith) 12 A VCDN12 VBDN12 VCCDN1220 A VCDN20 VBDN20 VCCDN20Backplate mounting in enclosure231/L13/L25/L34TypeVario for high performance applicationsDoor mountingColour: Handle / Front plate Red / Yellow Black / Black Red / Yellow Black / Black Red / Yellow Red / YellowBackplate mounting in enclosureFront plate dimensions (mm) 60 x 60 60 x 60 90 x 90 60 x 60 90 x 90Fixing Ø 22.5 mm 4 screws 4 screws Ø 22.5 mm 4 screws 4 screwsDegree of protection IP 20 IP 20 IP 20 IP 20 IP 20 IP 20Rated insulation voltage (Ui) 690 V 690 V 690 V 690 V 690 V 690 VThermal current in open air (Ith) 12 A VCD02 VBD02 VCF02 VBF02 – VCCD02 VCCF02 –20 A VCD01 VBD01 VCF01 VBF01 – VCCD01 VCCF01 –25 A VCD0 VBD0 VCF0 VBF0 – VCCD0 VCCF0 –32 A VCD1 VBD1 VCF1 VBF1 – VCCD1 VCCF1 –40 A VCD2 VBD2 VCF2 VBF2 – VCCD2 VCCF2 –63 A – – VCF3 VBF3 – – VCCF3 –80 A – – VCF4 VBF4 – – VCCF4 –125 A – – – – VCF5 – – VCCF5175 A – – – – VCF6 – – VCCF65678Add-on modules For mini-Vario For VarioMain pole modulesSwitch rating 12 A 20 A 12 A 20 A 25 A 32 A 40 A 63 A 80 AReferences VZN12 VZN20 VZ02 VZ01 VZ0 VZ1 VZ2 VZ3 VZ4Neutral pole module with early make and late break contactsSwitch rating 12…20 A 12…40 A 63 and 80 A 125 and 175 AReferences VZN11 VZ11 VZ12 VZ13Earthing moduleSwitch rating 12…20 A 12…40 A 63 and 80 A 125 and 175 AReferences VZN14 VZ14 VZ15 VZ16Auxiliary contact block modulesContact type NO NC NO + NC NO + NOReferences VZN05 VZN06 VZ7 VZ20910Other versions: please consult our Customer Care Centre.5/33


TeSysGV2, LCCombination motor starters0.06…15 kW12D.O.L. starterswith circuit-breakerwith fuse protectionLevel of service Coordination: Type 1 Type 2Power at 400 V Up to: 5.5 kW 15 kW 37 kWType of components Combination automatic motor starter with overload protection Fuse carrier +incorporated in the circuit-breakerplate-mounted contactorBasic reference, to be completed GV2ME GV2DM GV2DP LC4D345678Starters GV2-MENon-reversing ReversingStandard power ratings Setting Fixed For customer assembly Factory assembledof 3-phase motors range of magnetic Motor Contactor Basic reference, to be completed with50/60 Hz in category AC-3 (kW) thermal trips tripping current circuit-breaker code indicating control circuit voltage400/415 V 440 V 500 V 13 Irth0.37 0.37 0.37 1…1.6 22.5 GV2ME06 LC1K06 GV2ME06K1•• GV2ME06K2••0.55 0.55 0.55- - 0.750.75 0.75 - 1.6…2.5 33.5 GV2ME07 LC1K06 GV2ME07K1•• GV2ME07K2••- 1.1 1.11.1 - 1.5 2.5…4 51 GV2ME08 LC1K06 GV2ME08K1•• GV2ME08K2••1.5 1.5 2.22.2 2.2 - 4…6.3 78 GV2ME10 LC1K06 GV2ME10K1•• GV2ME10K2••- - 33 - 4 6…10 138 GV2ME14 LC1K09 GV2ME14K1•• GV2ME14K2••4 4 5.55.5 5.5 7.5 9…14 170 GV2ME16 LC1K12 GV2ME16K1•• GV2ME16K2••910Standard control circuit voltages (for other voltages, please consult your Regional Sales Office)Volts 24 110 220/230 230 230/240 380/400a 50…400 Hz B7 F7 M7 P7 U7 Q7c (1) BW3 - - - - -(1) Low consumption coil (1.5 W), wide range (0.7…1.3 Uc) and with integral suppression device as standard.5/34Other versions: please consult our Customer Care Centre.


1D.O.L. starters GV2DM and GV3-DPNon-reversing ReversingStandard power ratings Setting Fixed For customer assembly Factory assembledof 3-phase motors range of magnetic Motor Contactor Basic reference, to be completed with50/60 Hz in category AC-3 (kW) thermal trips tripping current circuit-breaker code indicating control circuit voltage400/415 V 440 V 500 V 13 Irth0.06 0.06 - 0.16…0.25 2.4 GV2ME02 LC1D09•• GV2DM102•• GV2DM202••GV2P02 LC1D09•• GV2DP102•• GV2DP202••0.09 0.09 - 0.25…0.40 5 GV2ME03 LC1D09•• GV2DM103•• GV2DM203••- 0.12 - GV2P03 LC1D09•• GV2DP103•• GV2DP203••0.12 - - 0.40…0.63 8 GV2ME04 LC1D09•• GV2DM104•• GV2DM204••0.18 0.18 - GV2P04 LC1D09•• GV2DP104•• GV2DP204••0.25 0.25 - 0.63…1 13 GV2ME05 LC1D09•• GV2DM105•• GV2DM205••0.37 0.37 - GV2P05 LC1D09•• GV2DP105•• GV2DP205••- - 0.37 1…1.6 22.5 GV2ME06 LC1D09•• GV2DM106•• GV2DM206••0.55 0.55 0.55 GV2P06 LC1D09•• GV2DP106•• GV2DP206••- - 0.750.75 0.75 - 1.6…2.5 33.5 GV2ME07 LC1D09•• GV2DM107•• GV2DM207••- 1.1 1.1 GV2P07 LC1D09•• GV2DP107•• GV2DP207••1.1 - 1.5 2.5…4 51 GV2ME08 LC1D09•• GV2DM108•• GV2DM208••1.5 1.5 2.2 GV2P08 LC1D09•• GV2DP108•• GV2DP208••2.2 2.2 - 4…6.3 78 GV2ME10 LC1D09•• GV2DM110•• GV2DM210••- 3 3 GV2P10 LC1D09•• GV2DP110•• GV2DP210••3 - 4 6…10 138 GV2ME14 LC1D09•• GV2DM114•• GV2DM214••4 4 5.5 GV2P14 LC1D09•• GV2DP114•• GV2DP214••5.5 5.5 7.5 9…14 170 GV2ME16 LC1D12•• GV2DM116•• GV2DM216••- 7.5 9 GV2P16 LC1D25•• GV2DP116•• GV2DP216••7.5 9 - 13…18 223 GV2ME20 LC1D18•• GV2DM120•• GV2DM220••GV2P20 LC1D25•• GV2DP120•• GV2DP220••9 11 11 17…23 327 GV2ME21 LC1D25•• GV2DM121•• GV2DM221••GV2P21 LC1D25•• GV2DP121•• GV2DP221••11 - 15 20…25 327 GV2ME22 LC1D25•• GV2DM122•• GV2DM222••GV2P22 LC1D25•• GV2DP122•• GV2DP222••15 15 18.5 24…32 416 GV2ME32 LC1D32•• GV2DM132•• GV2DM232••GV2P32 LC1D32•• GV2DP132•• GV2DP232•D.O.L. starters GV3 + LC1DNon-reversing ReversingStandard power ratings Setting Fixed For customer assemblyof 3-phase motors range of magnetic Motor Contactor Reference of accessory to be ordered50/60 Hz in category AC-3 (kW) thermal trips tripping current circuit-breaker for assembly of motor starter (2)400/415 V 440 V 500 V 13 Irth18,5 18,5 – 30…40 560 GV3P401 (1) LC1D40A•• – LAD9R3– 22 22 30…40 560 GV3P401 (1) LC1D40A•• – LAD9R322 – 30 37…50 700 GV3P501 (1) LC1D50A•• – LAD9R330 30 37 48…65 910 GV3P651 (1) LC1D65A•• – LAD9R3(1) Circuit-breaker GV3P without downstream EverLink terminal block. A standard GV3P can also be used by removing the downstream terminal block.(2) For side by side circuit-breaker/contactor mounting, order accessory GV3S.23456789Standard control circuit voltages (for other voltages, please consult your Regional Sales Office)Volts 24 220 230a 50…400 Hz B7 M7 P7c (3) BD – –(3) Low consumption coil, wide range (0.7 to 1.25 Uc) and with suppression device as standard (bidirectional peak limiting diode).10Other versions: please consult our Customer Care Centre.5/35


TeSys UStarter-controller for 3-phase motorsSTANDARD motor starter1= +23Function characteristics, LUB… + LUCA… Maximum Power base Standard control unitmotor power Non-reversing Reversing Class 10 Setting range< 400/415 V (1) (2)- Thermal overload protection against: 0.09 kW LUB12 LU2B12pp LUCA6Xpp 0.15…0.6 Ashort-circuit, overcurrent, 0.25 kW LUB12 LU2B12pp LUCA1Xpp 0.35…1.4 Aphase failure or imbalance, 1.5 kW LUB12 LU2B12pp LUCA05pp 1.25…5 Ainsulation breaks (equipment only). 5.5 kW LUB12 LU2B12pp LUCA12pp 3…12 A- Manual reset following thermal fault. 7.5 kW LUB32 LU2B32pp LUCA18pp 4.5…18 A15 kW LUB32 LU2B32pp LUCA32pp 8…32 AADVANCED motor starter456Function characteristics, LUB… + LUCA… Maximum Power base Advanced control unitmotor power Non-reversing Class 10 Class 20 Setting range< 400/415 V (2) (3) (2)- Thermal overload protection against: 0.09 kW LUB120 LUCB6Xpp LUCD6Xpp 0.15…0.6 Ashort-circuit, overcurrent, 0.25 kW LUB120 LUCB1Xpp LUCD1Xpp 0.35…1.4 Aphase failure or imbalance, 1.5 kW LUB120 LUCB05pp LUCD05pp 1.25…5 Ainsulation breaks (equipment only). 5.5 kW LUB120 LUCB12pp LUCD12pp 3…12 A- Manual reset following thermal fault. 7.5 kW LUB320 LUCB18pp LUCD18pp 4.5…18 A- Thermal overload test function. 15 kW LUB320 LUCB32pp LUCD32pp 8…32 A(3) For single-phase-motors, replace LUCBpppp by LUCCpppp.MULTIFUNCTION motor starter789Function characteristics, LUB… + LUCA…- Thermal overload protection against:short-circuit, overcurrent,phase failure or imbalance,insulation breaks (equipment only).- Manual, automatic or remote reset,- Thermal overload test function,- Overtorque and no-load running, alarm,- Motor operation log,- Motor parameters display on LUCM.., PC or HMI,- Integrated Modbus communication.Maximum Power base Multifunction control unitmotor power Non-reversing Class 5 to 30 Setting range< 400/415 V0.09 kW LUB120 LUCM6XBL 0.15…0.6 A0.25 kW LUB120 LUCM1XBL 0.35…1.4 A1.5 kW LUB120 LUCM05BL 1.25…5 A5.5 kW LUB120 LUCM12BL 3…12 A7.5 kW LUB320 LUCM18BL 4.5…18 A15 kW LUB320 LUCM32BL 8…32 A10(1) Complete the references of the power bases according to the following table. Example: LU2B12 pp(2) Complete the references of the control units according to the following table. Example: LUCA/B/D/M6X ppStandard control circuit voltages24 V DC BL24 V AC B48 V AC / 48…72 V DC ES110…240 V AC / 110…220 V DC FU5/36Other versions: please consult our Customer Care Centre.


TeSys UStarter-controller for 3-phase motorsFunction modules+=1Type of optional function Thermal Thermal fault signalling Motor loadoverload alarmindicationCompatible with LUCA NO NO NO NO NOCompatible with LUCL NO NO NO NO NOCompatible with LUCB, LUCD YES YES YES YES YESCompatible with LUCM NO NO NO NO YESOutput signal 1 NO 1 NO +1 NC 1 NC 1 NO 4…20 mAReset NA Manual Automatic or remote NAReferences LUFW10 LUFDH11 LUFDA01 LUFDA10 LUFV2Communication modules234Type of communication Modbus Modicon Profibus DP CANopen DeviceNet AS-Interface ParallelSTBwiringOnly compatible with 24 V DC control units YES YES YES YES YES YES YESLUCA..BL, LUCB..BL, LUCD..BL, LUCM..BLTransfer speed 19.2 Kbps Dpg. on NIM (1) 9.6…12 Mbps 20 K…1 Mbps 125…500 Kbaud 167 Kbps NANumber of slaves 31 per Modbus Dpg. on Network 125 per Profibus DP 128 per CANopen 63 per DeviceNet 62 per AS-Interface 8 per LU9GC02master Interface Module module module module master splitter boxPre-wired coil connection (A1 A2) LU9BN11C, LU9BN11L, LU9BN11L, LU9BN11L, LU9BN11L, LU9BN11C, LU9RxxLU9MRC LU9MRL LU9MRL LU9MRL LU9MRL LU9MRCConnecting cable to PC VW3 A8 306 Rpp LU9RCDpp, TSXPBSCApp TSXCANCpp DeviceNet XZCG0142 TSXCDPpppLU9RDDppstandardReferences LUFC033 LULC15 LULC07 LULC08 LULC09 ASILUFC51 LUFC00(1) Network Interface Module.Information carried by the Modbus, Modicon STB or CANopen busType of control unit LUCAppBL LUCBppBL, LUCDppBL LUCMppBLStart and Stop commands X X <strong>XS</strong>tarter status (ready, running, fault) X X XThermal alarm X XRemote reset via the bus X XIndication of motor load X <strong>XS</strong>ignalling and fault differentiation X XAlarms (overcurrent, …)XRemote programming and monitoring of all the functionsX“Log” functionXMonitoring functionXContact blocks56789Type of contact block Add-on AuxiliarySignalling contacts of any fault NC (95-96) NO (97-98) – – –position of control handle NO (17-18) NO (17-18) – – –2 auxiliary contacts module – – NO (33-34) NC (31-32) NC (31-32)– – NO (43-44) NO (43-44) NC (41-42)References Screw clamp terminals LUA1C11 LUA1C20 LUFN20 LUFN11 LUFN02Without connections LUA1C110 LUA1C200 – – –10Other versions: please consult our Customer Care Centre.5/37


TeSysLUTMTeSys GV3LCircuit-breakersController for 3-phase motorsMULTIFUNCTION protection1TeSys LC1DContactor= +234Function characteristics Control base for use Multifunctionwith contactorscontrol unitTeSys D (LC1D..) TeSys F (LC1F..) Class 5 to 35- Thermal overload protection against: LUTM10BL LUTM20BL LUCMT1BLshort-circuit, overcurrent,phase failure or imbalance,insulation breaks (equipment only).- Manual, automatic or remote reset,- Thermal overload test function,- Overtorque and no-load running, alarm,- Motor operation log,- Motor parameters display on LUCM.., PC or HMI,- Integrated Modbus communication.ADVANCED protection567Function characteristics Control base for use Advancedwith contactorscontrol unitTeSys D (LC1D..) TeSys F (LC1F..) Class 10 Class 20- Thermal overload protection against: LUTM10BL LUTM20BL LUCBT1BL LUCDT1BLshort-circuit, overcurrent,phase failure or imbalance,insulation breaks (equipment only).- Manual reset following thermal fault.- Thermal overload test function.8Current transformers910Type of transformerSupply voltage24 V DCOperating current Primary 30 A 50 A 100 A 200 A 400 A 800 ASecondary1 AReferences LUTC0301 LUTC0501 LUTC01001 LUTC02001 LUTC04001 LUTC05001Above 32 A, the TeSys U controller provides a motor starter management system solution identical to that provided by the TeSys U starter-controller.Used in conjunction with a short-circuit protection device and a contactor, it provides a motor starter whose functions are the same as those of a TeSys U starter-controllerand, in particular, provides the following functions: overload protection, motor starter control and application monitoring.It comprises a control unit, whose adjustment range is compatible with the secondary of current transformers, and a control base that also enables the fitting of a function module orcommunication module.It requires a 24 V DC external power supply.5/38Other versions: please consult our Customer Care Centre.


TeSysLUTMController for 3-phase motorsFunction modules+=1Type of optional function Thermal overload alarm Motor load indicationCompatible with LUCA NO NOCompatible with LUCL NO NOCompatible with LUCB, LUCD YES YESCompatible with LUCM NO YESOutput signal 1 NO 4…20 mAReset NA NAReferences LUFW10 LUFV223TeSys rotating handles forKit IP54 black handleIP54 kit red handle and yellow frontIP65 kit red handle and yellow frontTeSys ULU9APN21LU9APN22LU9APN24Communication modules45Type of communication Modbus Modicon STB CANopen DeviceNet ParallelwiringOnly compatible with 24 V DC control units YES YES YES YES YESLUCA..BL, LUCB..BL, LUCD..BL, LUCM..BLTransfer speed 19.2 Kbps Dpg. on NIM (1) 20 K…1 Mbps 125…500 Kbaud NANumber of slaves 31 per Modbus Dpg. on Network 128 per CANopen 63 per DeviceNet 8 per LU9GC02master Interface Module module module splitter boxPre-wired coil connection (A1 A2) LU9BN11C, LU9BN11L, LU9BN11L, LU9BN11L, LU9RxxLU9MRC LU9MRL LU9MRL LU9MRLConnecting cable to PC VW3 A8 306 Rpp LU9RCDpp TSXCANCpp DeviceNet TSXCDPpppLU9RDDppstandardReferences LUFC033 LULC15 LULC08 LULC09 LUFC00678Information carried by the Modbus, Modicon STB or CANopen busType of control unit LUCBT1BL, LUCDT1BL LUCMT1BLStart and Stop commands X <strong>XS</strong>tarter status (ready, running, fault) X XThermal alarm X XRemote reset via the bus X XIndication of motor load X <strong>XS</strong>ignalling and fault differentiation X XAlarms (overcurrent, …)XRemote programming and monitoring of all the functionsX“Log” functionXMonitoring functionX910Other versions: please consult our Customer Care Centre.5/39


TeSysEnclosed motor starters0.06…132 kW1234Starters D.O.L. standardStandard power ratings of 3-phase motors in category AC3 400/415 V 4…37 kW 0.06…37 kW 0.55…30 kW 0.37…5.5 kW 0.25…45 kWStarters manual - -auto - - - Isolating device switch-disconnector-fuse - - - -circuit-breaker - -fuse carrier - - - - -Protection short-circuit - -overload - - Communication - - - - -Basic reference Non-reversing V•F•GE GV2ME GV2LC LE1GVME LE1MVCFN•GE GV3PC GV-NGC LE1DV•FXGE•GV3CEReversingLE2KLE2D56789105/40Other versions: please consult our Customer Care Centre.


1■ 2 stage safety applications AS-Interface bus standard star-delta2.2…45 kW 0.06…11 kW 0.06…9 kW 0.06…9 kW 0.06…5.5 kW 5.5…132 kW 7.5…75 kW- - - - - - - - - - - - -- - - - - - - - - - - - - - -LE4K GV2ME LG1K LG7K LF3M LE3K LE6DLE4D LG1D LG7D LF3P LE3D LE3DLJ7K LF7P LE3FLE8K LG8K LF4MLE8D LJ8K LF4PLE2DLF8P2345678910Other versions: please consult our Customer Care Centre.5/41


TeSysQuickfitInstallation systemPresentation123456TeSys Quickfit is a modular system which standardises and simplifies the implementation of motor starterswith its pre-wired control and power circuits.Installation of a motor starter becomes quick, simple, safe and flexible.In addition, this system:b enables the motor starter to be customised at a later date,b reduces maintenance time andb optimises panel space by reducing the number of terminals and intermediate interfaces and the amountof ducting.The motor starters concerned are those created by combining:– GV2 ME or GV3 P circuit-breakers, with an operating limit of 80% of the maximum current at an ambienttemperature of 60 °C, up to 690 V– with 9 to 65 A TeSys D (LC1) contactors.This offer comprises components for pre-wiringb the power part,b the control part.Components for pre-wiring the power partb a power kit comprising, for each starter, a plate for mounting the contactor and the circuit-breaker, andtwo power connection modules,b a power splitter box for 2 or 4 starters,b an upstream terminal block for a power supply up to 60 A (16 mm 2 ),b a downstream terminal block for connecting the motor power supply cables and the earth cables(6 mm 2 ).Components for pre-wiring the control partb a control circuit connection module that mounts directly on the contactor and the circuit-breaker ofeach starter. This module integrates the status and control information of this particular motor starter.b a parallel wiring module enabling grouping of the information relating to each motor starter:v HE 10, intended for centralised applications. The information is transmitted to the PLC via the Modiconpre-wired system.v STB, intended for decentralised automation architectures. This module is integrated in an Modicon STBconfiguration for connection to the PLC via a fieldbus.9…25 A power pre-wiring components78Type Terminal block 60 A power splitter boxUpstream Downstream Extension by LAD32pMaximum c.s.a. of connection 16 mm 2 6 mm 2 – –Use Splitter boxes supply Motor cables – –Number of starters – – 2 4Reference LAD3B1 LAD331 LAD322 LAD324910Type Connection kit Mounting plate for Power connectionFor D.O.L. starter (1) GV2 ME & contactor moduleComposition 1 mounting plate LAD311 for GV2ME For 1 motor starter2 power connection modules LAD341Reference LAD252 LAD311 LAD341(1) For a reversing starter order 2 connection kits LAD2525/42Other versions: please consult our Customer Care Centre.


Control-command pre-wiring components1TypeConnection moduleTeSys D coil voltage 12…250 V AC or 5…130 V DC 24 V DCType of coil control relay Electronic Without relayType of motor starter Direct Reversing Direct ReversingReference LAD9AP31 LAD9AP32 LAD9AP3D1 LAD9AP3D223Type24 V DC parallel wiring moduleSplitter boxModicon STB parallel interface modulePLC/motor starter side connectors 2 x HE10/8 x RJ45 –/4 x RJ45Reference LU9G02 STBEPI214545Accessories6TypeConnecting cables(1) From splitter box LU9G02 to the PLCConnectors 2 x RJ45 2 HE10 Bare wires and HE10Gauge / c.s.a. – 22 / 0.324 mm 2 28 / 0.080 mm 2 22 / 0.324 mm 2Reference L = 0.3 m LU9R03 – – –0.5 m – TSXCDP053 – –1 m LU9R10 TSXCDP103 ABFH20H100 –2 m – TSXCDP203 ABFH20H200 –3 m LU9R30 TSXCDP303 ABFH20H300 TSXCDP3015 m – TSXCDP503 – TSXCDP301(1) From connection module LAD9AP3p to splitter box LU9G02 or module STBEPI2145789Type Connectors Connecting cableSpring terminals Self-strippingUse External contact, auxiliary power supply Between communication module APP1Cp andsplitter box LU9GG02Reference APE1PRE21 APE1PAD21 APP2AH40H06010Other versions: please consult our Customer Care Centre.5/43


ComponentsLighting applications (AC5)1234567Sodium vapour lamps low pressureNon-correctedWith parallel compensationP (W) 3- 55 90 135 150 180 200 35 55 90 135 150 180 200IB (A) 1.2 1.6 2.4 3.1 3.2 3.3 3.4 0.3 0.4 0.6 0.9 1 1.2 1.3C (μF) - - - - - - - 17 17 25 36 36 36 36 LC1-Max. number of lamps 6 5 3 2 2 2 2 - - - - - - - K09according to P (W), per contactor 10 7 5 3 3 3 3 40 30 - - - - - D09, D1212 9 6 4 4 4 4 50 37 25 - - - - D1815 11 7 6 5 5 5 63 47 31 21 19 15 14 D2521 16 10 8 8 7 7 86 65 43 28 26 21 20 D32, D3827 20 13 10 10 10 9 110 82 55 36 33 27 25 D40A35 26 17 13 13 12 12 140 105 70 46 42 35 32 D50A, D65A50 37 25 19 18 18 17 200 150 100 66 60 50 46 D80, D95100 75 50 38 36 36 34 400 300 200 132 120 100 92 D115, D150140 104 70 54 52 50 48 560 420 280 186 168 140 128 F185152 114 76 58 56 54 54 606 454 302 202 182 152 140 F225174 130 88 68 66 64 62 700 524 350 232 210 174 162 F265198 148 98 76 74 72 70 792 594 396 264 238 198 182 F330250 188 124 96 94 90 88 1002 752 502 334 300 250 252 F400338 254 168 130 126 122 118 1352 1014 676 450 406 338 312 F500496 372 248 192 186 180 174 1982 1488 992 660 594 496 458 F600, F800 high pressureP (W) 150 250 400 700 1000 150 250 400 700 1000IB (A) 1.9 3.2 5 8.8 12.4 0.84 1.4 2.2 3.9 5.5C (μF) - - - - - 20 32 48 96 120 LC1-Max. number of lamps 4 2 1 - - - - - - - K09according to P (W), per contactor 6 3 2 1 - - - - - - D09, D127 4 3 1 1 17 - - - - D1810 5 3 2 1 22 13 8 - - D2513 8 5 2 2 30 18 11 6 - D32, D3817 10 6 3 2 39 23 15 8 6 D40A22 13 8 4 3 50 30 19 10 7 D50A, D65A31 18 12 6 4 71 42 27 15 10 D80, D9562 36 24 12 8 142 84 54 30 20 D115, D15088 52 34 18 14 200 120 76 42 30 F18596 56 36 20 16 216 130 82 46 32 F225110 66 42 24 18 250 150 94 54 38 F265124 74 48 26 20 282 170 108 60 42 F330158 94 60 34 24 358 214 136 76 54 F400214 126 80 46 32 482 290 184 104 74 F500312 186 118 68 48 708 424 270 152 108 F630, F800Metal iodine vapour lamps8910P (W) 250 400 1000 2000 250 400 1000 2000IB (A) 2.5 3.6 9.5 20 1.4 2 5.3 11.2C (μF) - - - - 32 32 64 140 LC1-Max. number of lamps 3 2 - - - - - - K09according to P (W), per contactor 4 3 1 - - - - - D09, D126 4 1 - - - - - D187 5 2 - 13 9 - - D2510 7 2 1 18 13 4 - D32, D3813 9 3 1 23 16 6 - D40A16 11 4 2 30 21 7 - D50A, D65A24 16 6 3 42 30 11 5 D80, D9548 32 12 6 84 60 22 10 D115, D15066 46 18 8 120 84 32 14 F18572 50 20 10 130 90 34 16 F22584 58 22 12 150 104 40 18 F26594 66 24 14 170 118 44 20 F330120 84 32 16 214 150 56 26 F400162 112 42 20 290 202 76 36 F500238 164 62 30 424 298 112 52 F630, F8005/44Other versions: please consult our Customer Care Centre.


Incandescent and halogen lampsP (W) 60 75 100 150 200 300 500 750 1000IB (A) 0.27 0.34 0.45 0.68 0.91 1.40 2.30 3.40 4.60 LC1-Max. number of lamps 35 28 21 14 10 6 4 2 2 K09according to P (W), per contactor 59 47 35 23 17 11 7 4 3 D09, D1277 61 46 30 23 15 9 6 4 D1892 73 55 36 27 18 11 7 5 D25129 103 77 51 38 25 15 10 7 D32, D38163 129 97 64 48 31 19 13 9 D40A207 164 124 82 62 40 24 16 12 D50A, D65A296 235 177 117 88 57 34 23 17 D80, D95430 340 256 170 126 82 50 34 24 D115466 370 280 184 138 90 54 36 26 D150710 564 426 282 210 136 82 56 40 F185770 610 462 304 228 148 90 60 44 F225888 704 532 352 262 170 104 70 52 F2651006 800 604 400 298 194 118 80 58 F3301274 1010 764 504 378 244 148 100 74 F4001718 1364 1030 682 508 330 200 136 100 F5002328 1850 1396 924 690 448 272 184 136 F6002776 2204 1666 1102 824 534 326 220 162 F800Fluorescent lamps with starter single fittingNon-correctedWith parallel correctionP (W) 20 40 65 80 110 20 40 65 80 110IB (A) 0.39 0.45 0.70 0.80 1.2 0.17 0.26 0.42 0.52 0.72C (μF) - - - - - 5 5 7 7 16 LC1-Max. number of lamps 24 21 13 12 8 56 36 22 18 - K09according to P (W), per contactor 41 35 22 20 13 94 61 38 30 22 D09, D1253 46 30 26 17 123 80 50 40 29 D1866 57 37 32 21 152 100 61 50 36 D2589 77 50 43 29 205 134 83 67 48 D32, D38112 97 62 55 36 258 169 104 84 61 D40A143 124 80 70 46 329 215 133 107 77 D50A, D65A205 177 114 100 66 470 367 190 153 111 D80, D95410 354 228 200 132 940 614 380 306 222 D115, D150492 426 274 240 160 1128 738 456 368 266 F185532 462 296 260 172 1224 800 490 400 288 F225614 532 342 300 200 1412 922 570 462 332 F265696 604 388 340 226 1600 1046 648 522 378 F330882 764 490 430 286 2024 1322 818 662 478 F4001190 1030 662 580 386 2728 1724 1104 892 644 F5001612 1398 698 786 524 3700 2418 1498 1210 874 F630, F800■ twin fittingP (W) 2x20 2x40 2x65 2x80 2x110 2x20 2x40 2x65 2x80 2x110IB (A) 2x0.22 2x0.41 2x0.67 2x0.82 2x1.1 2x0.13 2x0.24 2x0.39 2x0.48 2x0.65 LC1-Max. number of lamps 2x21 2x11 2x7 2x5 2x4 2x36 2x20 2x12 2x10 2x7 K09according to P (W), per contactor 2x36 2x18 2x10 2x8 2x6 2x60 2x32 2x20 2x16 2x12 D09, D122x46 2x24 2x14 2x12 2x8 2x80 2x42 2x26 2x20 2x16 D182x58 2x30 2x18 2x14 2x10 2x100 2x54 2x32 2x26 2x20 D252x78 2x42 2x26 2x20 2x14 2x134 2x72 2x44 2x36 2x26 D32, D382x100 2x52 2x32 2x26 2x18 2x168 2x90 2x56 2x44 2x32 D40A2x126 2x68 2x40 2x34 2x24 2x214 2x116 2x70 2x58 2x42 D50A, D65A2x180 2x96 2x58 2x48 2x36 2x306 2x166 2x102 2x82 2x60 D80, D952x360 2x194 2x118 2x96 2x72 2x614 2x332 2x204 2x166 2x122 D115, D1502x436 2x234 2x142 2x116 2x86 2x738 2x400 2x246 2x200 2x148 F1852x472 2x254 2x154 2x126 2x94 2x800 2x432 2x266 2x216 2x160 F2252x544 2x292 2x178 2x146 2x108 2x922 2x500 2x308 2x250 2x184 F2652x618 2x332 2x202 2x166 2x124 2x1046 2x566 2x348 2x282 2x208 F3302x782 2x420 2x256 2x210 2x156 2x1322 2x716 2x440 2x358 2x264 F4002x1054 2x566 2x346 2x282 2x210 2x1784 2x966 2x594 2x482 2x356 F5002x1430 2x766 2x468 2x384 2x286 2x2418 2x1310 2x806 2x654 2x484 F630, F80012345678910Other versions: please consult our Customer Care Centre.5/45


ComponentsCapacitor switching0…1000 kVAR12345On-load capacitor switchingfor bar-mounted contactors, a.c. control circuitWithout damping resistorWith damping resistorRated operational voltage (V) Number of poles Max. operational Basic reference, Number of poles Max. operational Basic reference,current (A) to be completed current (A) to be completed50 Hz 180 Hz 50 Hz 180 Hz1300 1 80 60 CE5FB11•11 1 + 1 staggered pole 80 60 CE6FB12•11160 125 CE5GB11•11 160 125 CE6GB12•11240 190 CE5HB11•11 240 190 CE6HB12•112 80x2 60x2 CE5FB21•11160x2 125x2 CE5GB21•11240x2 190x2 CE5HB21•11 2 + 2 staggered poles 240x2 190x2 CE6HB22•113 80x3 60x3 CE5FB31•11160x3 125x3 CE5GB31•11240x3 190x3 CE5HB31•11 1 + 2 staggered poles1500 2 poles in series 160 125 CE5GB12•11 160 125 CE6GB13•11280 220 CE5HB12•11 280 220 CE6HB13•112 x 2 poles in series 280x2 220x2 CE5HB22•112000 2 poles in series 240 190 CS5HB12•11 1 + 2 staggered poles 240 190 CS6HB13•112 x 2 poles in series 240x2 190x2 CS5HB22•113000 3 poles in series 280 220 CS5HB13•11 1 + 3 staggered poles 280 220 CS6HB14•116Standard control circuit voltagesa supplyVolts 110 125 127 200 220 240 250 380 415 440 50050 Hz (coil LX1) F - G L M U - Q N R S789105/46Other versions: please consult our Customer Care Centre.


1Maximum operational power of contactors standard contactorsOperational power at 50/60 Hzθ ≥ 40 °C θ ≥ 55 °C Peak current Contactor220 V 400 V 600 V 220 V 400 V 600 V size240 V 440 V 690 V 240 V 440 V 690 VkVAR kVAR kVAR kVAR kVAR kVAR A6 11 15 6 11 15 560 LC1D09, D129 15 20 9 15 20 850 LC1D1811 20 25 11 20 25 1600 LC1D2514 25 30 14 25 30 1900 LC1D32, D3817 30 37 17 30 37 2160 LC1D40A22 40 50 22 40 50 2160 LC1D50A22 40 50 22 40 50 3040 LC1D65A35 60 75 35 60 75 3040 LC1D80, D9550 90 125 38 75 80 3100 LC1D11560 110 135 40 85 90 3300 LC1D15070 125 160 50 100 100 3500 LC1F18580 140 190 60 110 110 4000 LC1F22590 160 225 75 125 125 5000 LC1F265100 190 275 85 140 165 6500 LC1F330125 220 300 100 160 200 8000 LC1F400180 300 400 125 220 300 10000 LC1F500250 400 600 190 350 500 12000 LC1F630250 400 600 190 350 500 14200 LC1F800200 350 500 180 350 500 25000 LC1BL300 550 650 250 500 600 25000 LC1BM500 8350 950 400 750 750 25000 LC1BP600 1100 1300 500 1000 1000 25000 LC1BR special contactorsOperational power at 50/60 Hzθ ≥ 55 °C Instantaneous auxiliary contacts Tightening torque on cable end Basic reference,220 V 400 V 660 V to be completed240 V 440 V 690 VkVAR kVAR kVAR NO NC N.m6.7 12.5 18 1 1 1.2 LC1DFK11••- 2 1.2 LC1DFK02••8.5 16.7 24 1 1 1.7 LC1DGK11••- 2 1.7 LC1DGK02••10 20 30 1 1 1.9 LC1DLK11••- 2 1.9 LC1DLK02••15 25 36 1 1 2.5 LC1DMK11••- 2 2.5 LC1DMK02••20 33.3 48 1 2 5 LC1DPK12••25 40 58 1 2 5 LC1DTK12••40 60 92 1 2 9 LC1DWK12••23456789Standard control circuit voltagesa supplyVolts 24 42 48 110 115 220 230 240 380 400 415 44050/60 Hz (coil LX1) B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R710Other versions: please consult our Customer Care Centre.5/47


ComponentsHeating applications and changeovercontactor pairs0…2750 A1Maximum operational current (device in open air)234Contactors LC1-/LP1- LC1-/LP1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- 3-pole K09 K12 D09 D12 D18 D25 D32 D38 D40A 4-pole DT20 DT25 DT32 DT40LC2- changeover contactor pairs, factory assembled K09004 K12004 DT20 DT25 DT32 DT40 DT60AOperational current in AC-1, in A, ≤ 40°C A 20 20 25 20 25 32 40 50 50 60according to ambient temperature ≤ 60°C A 20 20 25 20 25 32 40 50 50 60≤ 70°CMaximum operational 220/230 V kW 8 8 9 8 9 11 14 18 18 21power ≤ 60°C 240 V kW 8 8 9 8 9 12 15 19 19 23380/400 V kW 14 14 15 14 15 20 25 31 31 37415 V kW 14 14 17 14 17 21 27 34 34 41440 V kW 15 15 18 15 18 23 29 36 36 43500 V kW 17 17 20 17 20 23 33 41 41 49660/690 V kW 22 22 27 22 27 34 43 54 54 655678910Increase in operational currentby parallel connection of polesApply the following coefficients to the currents or powers above;these coefficients take into account an often unbalanced distributionof current between the poles: 2 poles in parallel K = 1.6 3 poles in parallel K = 2.25 4 poles in parallel K = 2.8Connection accessories for heating applicationsParalleling links for:Reference TeSys K 2 poles with screw clamp terminals LA9E014 poles with screw clamp terminals LA9E02 TeSys D 2 poles D09…D38 LA9D2561DT20 and DT25 (4P)LA9D1261DT32…DT40 (4P)LADD96061D40A…D65ALAD9P32D80LA9D809613 poles D09…D38 LAD9P3 (1)D40A…D65ALAD9P33D80LA9D809624 poles DT20…DT25 LA9D1263D40A…D65A2 x LAD-9P33D80LA9D80963 TeSys F 2 to 2 LC1F1154 LA9FF602LC1F1504, F1854LA9FG602LC1F2254, F2654, F3304, F4004LA9FH602LC1F5004LA9FK602LC1F6304LA9FL602(1) Link that can be split, allowing parallel connection of 2 poles5/48Other versions: please consult our Customer Care Centre.


1LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1- LC1-D50A D65A D80 D115 F185 F225 F265 F330 F400 F500 F630 F780 F800 BL BM BP BR2DT80A D80004 D115004 F1854 F2254 F265480 80 125 250 275 315 350 400 500 700 1000 1600 1000 800 1250 2000 275080 80 125 200 275 280 300 360 430 580 850 1350 850 700 1100 1750 2400180 200 250 290 340 500 700 1100 700 600 900 1500 200029 29 45 80 90 100 120 145 170 240 350 550 350 300 425 700 100031 31 49 83 100 110 125 160 180 255 370 570 370 330 450 800 110050 50 78 135 165 175 210 250 300 430 600 950 600 500 800 1200 160054 54 85 140 170 185 220 260 310 445 630 1000 630 525 825 1250 170058 58 90 150 180 200 230 290 330 370 670 1050 670 550 850 1400 200065 65 102 170 200 220 270 320 380 660 750 1200 750 600 900 1500 210086 86 135 235 280 300 370 400 530 740 1000 1650 1000 800 1100 1900 2700345678910Other versions: please consult our Customer Care Centre.5/49


ComponentsAccessories for changeover contactor pairs0…2750 A123456789Mounting accessories for changeover contactor pairs(for customer assembly)Contactor type Set of power connections Mechanical Contactor type Set of power connections Mechanicalinterlockinterlock2 contactors, vertically mounted 4-pole changeover pairs with locking device componentsLC1B – EZ2LB0601 – – –2 identical contactors, horizontally mounted with electrical interlocking kit for the contactorsLC1DT20…DT40 LAD-T9R1V (1) – – – – mechanical interlock with integral electrical interlockingLP1D80004 LA9D8070 LA9D8002 LC1D115004 LA9D11570 LA9D11502 without electrical interlocking (2)LC1DT20…DT40 LAD-T9R1 (2) – – – –LC1DT60A & LC1DT80A – LAD4CM (3) LP1D80004 LA9D8070 LA9D809782 contactors of identical rating, horizontally mounted 4-pole changeover pairsLC1F1154 LA9FF977 LA9FF970 LC1F1504 LA9F15077 LA9FF970LC1F1854 LA9FG977 LA9FG970 LC1F2254 LA9F22577 LA9FG970LC1F2654 LA9FH977 LA9FJ970 LC1F3304 LA9FJ977 LA9FJ970LC1F4004 LA9FJ977 LA9FJ970 LC1F5004 LA9FK977 LA9FJ970LC1F6304 LA9FL977 LA9FL970 – – – 3-pole changeover pairs with electrical interlockingLC1D115 et D150 LA9D11571 LA9D11502 – – –reversers assembled using 2 contactors, vertically mounted 4-pole changeover pairs using contactors of identical rating (3) 3 or 4-pole changeover pairs using contactors of different ratingAt bottomAt topLC1F1154 or F1505 (3) LA9FF4F LC1F115 or F1154 LC1F185 or F1854 LA9FG4FLC1F1854 (3) LA9FG4G or LC1F150 or F1504 LC1F225 or F2254 LA9FG4FLC1F2254 (3) LA9FG4G LC1F265 or F2654 LA9FH4FLC1F2654 or F3304 (3) LA9FH4H LC1F300 or F3304 LA9FH4FLC1F4004 (3) LA9FJ4J LC1F400 or F4004 LA9FJ4FLC1F5004 (3) LA9FK4K LC1F500 or F5004 LA9FK4FLC1F6304 (3) LA9FL4L LC1F630, F6304 or F800 LA9FL4FLC1F7804 (4) LA9FX971 (4) LC1F185 or F1854 LC1F265 or F2654 LA9FH4Gor LC1F225 or F2254 LC1F330 or F3304 LA9FH4GLC1F400 or F4004LA9FJ4GLC1F500 or F5004LA9FK4GLC1F630, F6304 or F800 LA9FL4GLC1F265 or F2654 LC1F400 or F4004 LA9FJ4Hor LC1F330 or F3304 LC1F500 or F5004 LA9FK4HLC1F630, F6304 or F800 LA9FL4HLC1F400 or F4004 LC1F500 or F5004 LA9FK4JLC1F630, F6304 or F800 LA9FL4JLC1F500 or F5004 LC1F630, F6304 or F800 LA9FL4K(1) Including mechanical interlock.(2) Order separately 2 auxiliary contact blocks LAD-N•1 t o obtain electrical interlocking between the two contactors.(3) Power connections to be made by the customer.(4) Double mechanical interlock mechanism with 2 interlock connecting rods and 4 power connecting links.105/50Other versions: please consult our Customer Care Centre.


TeSysNotes12345678910Other versions: please consult our Customer Care Centre.5/51


PhaseoPhaseo offers universal power suppliesand protection modules with a very wideoperating range to provide continuityof service for your installations.An innovative offer, Phaseo integratesnumerous features which set thestandard across this market.Schneider Electric offers completeand compact ranges of power supplies(switch mode or filtered rectified)and transformers.With the Phaseo range, yourinstallations will be equippedwith a high quality AC or DC powersupply compliant with internationalstandards.


Power SuppliesThis document is a selection ofthe top selling products.1Power suppliesRegulated switch mode, filtered rectified power suppliesAccessoriesPhaseo ABL8, ABL4, ABL1 ......................................................................................... 6/2 to 6/523TransformersPhaseo ABL6, ABT7 .................................................................................................................. 6/64ConnectionTerminal blocksAB1 ........................................................................................................................................ 6/8Cable endsDZ5/AZ5 ................................................................................................................................. 6/956789106/1


PhaseoPower suppliesRegulated switch mode - Rail mounting1Type of power supply7 to 60 W Single-phase23Rated input voltage100…240 VACRated output voltage 24 V 5 V 12 VRated power / Rated output current 7.5 W / 0.3 A 15 W / 0.6 A 30 W / 1.2 A 60 W / 2.5 A 20 W / 4 A 25 W / 2 AResetAutoConformity to IEC 61000-3-2WithoutCertificationscULus, cCSAus, TUV, CE, C-TickDimensions W x D x H (mm) 36 x 59 x 90 54 x 59 x 90 72 x 59 x 90 54 x 59 x 90Fixing (mm)DIN rail 35x7.5 or 35x15 or on panel mount by screwReferences ABL8MEM24003 ABL8MEM24006 ABL8MEM24012 ABL7RM24025 ABL8MEM05040 ABL8MEM120204567Type of power supply72 to 240 W Single-phase - Wide input rangeRated input voltage100…120 VAC and 200…500 VACRated output voltage24 VRated power / Rated output current 72 W / 3 A 120 W / 5 A 240 W / 10 APermissible temporary inrush current (boost)1.5 In during 4 sResetAuto or manualConformity to IEC 61000-3-2YesDiagnostic relay (output voltage > 21.6V) No YesCertificationscCSAus, CB scheme, CEDimensions W x D x H (mm) 44 x 120 x 143 56 x 120 x 143 85 x 140 x 143Fixing (mm)DIN rail 35x7.5 or 35x15References ABL8RPS24030 ABL8RPS24050 ABL8RPS24100Regulated, Switch-modeCompact - Rail mounting8910Type of power supply85 to 480W Single-phaseRated Input Voltage AC 120…230V 50/60Hz 120/230VRated Input Voltage DC 100…370V 300…350 VOutput Voltage 24V rated adjustable 23…27,5 V 24V rated 24…28VRated power / Rated output current 84W / 3,5A 120W / 5A 240W /10A 480W / 20ATemporary permissible inrush current output 6A for 30s 8A for 30s 15A for 30s 30A for 5sReset after overloadAutoDiagnostic relay (output voltage > 21.6V)YesFixing (mm) DIN rail 35 x 7,5Dimensions W x D x H (mm) 39 x 115 x 134 64 x 140 x 139References ABL4RSM24035 ABL4RSM24050 ABL4RSM24100 ABL4RSM242006/2Other versions: please consult your Schneider Electric agency.


160 to 144 W single-phase100…240 VAC24 V 12 V 48 V72 W / 3 A 120 W / 5 A 60 W / 5 A 144 W / 2.5 AAutoAuto or manualNoYescULus, cCSAus, TUV, CE, C-Tick27 x 120 x 120 54 x 120 x 120DIN rail 75x7.5, 35x7.5 or 35x15ABL8REM24030 ABL8REM24050 ABL7RP1205 ABL7RP4803234480 to 960 W single and 3-phases100…120 VAC and 200…240 VAC 3 x 380…500 VAC24 V480 W / 20 A 960 W / 40 A1.5 In during 4 sAuto or manualYesYescCSAus, CB scheme, CE145 x 140 x 143 95 x 155 x 143 165 x 155 x 143DIN rail 35x7.5 or 35x15ABL8RPM24200 ABL8WPS24200 ABL8WPS24400Type of moduleCompatibilityRated outputvoltageRated outputcurrentCertificationsConverters DC/DCOutput connection of power supplies ABL8RPS24…,ABL8WPS24…, ABL4RSM24... and ABL4WSR24...5 V 12 V6 A 2 AcCSAus, CB scheme, CEDimensions W x D x H (mm) 44 x 140 x 146Fixing (mm)DIN rail 35x7.5 or 35x15References ABL8DCC05060 ABL8DCC120205678Type of power supply480 to 960W 3-phaseRated Input Voltage AC400 … 500V 50/60 HzWorking on 2 phasesPossible with output current = 75% of the nominal output current.Output Voltage24VRated power / Rated output current 480W / 20A 720W / 30A 960W / 40ATemporary permissible inrush current output 30A for 5s 45A for 5s 60A for 5sReset after overloadAutoDiagnostic relayYesFixation (mm) DIN rail 35 x 7,5Dimensions W x D x H (mm) 80 x 127 x 146References ABL4WSR24200 ABL4WSR24300 ABL4WSR24400910Other versions: please consult your Schneider Electric agency.6/3


Phaseo SlimPower suppliesFunction modules for regulated switch modepower supplies.203,2AH 7AH 12AH101TEMPS DE MAINTIENmn h426040201040200mA1000 10A20 40COURANT DE MAINTIENType of module Microcuts and cuts network solutions. (1)234CompatibilityOutput connection of Universal power supplies ABL8RPS24…, ABL8WPS24…, ABL4RSM24...,ABL4WSR24...Technology Buffer module battery backup module + batteryRated output voltage 40 A 20 A 40 AHolding time 1A 2 s typique adjustable from 10 s to 24 H (battery depending)Holding time for maximum current output 100 ms typique adjustable from 10 s to 30 mn(battery depending)adjustable from 10 to 10 mn(battery depending)CertificationscCSAus, CB scheme, CEDimensions W x D x H (mm) 85 x 140 x 146 86 x 175 x 143 86 x 175 x 143Fixing (mm) DIN rail 35x7.5 or 35x15 (1)References Control module ABL8BUF24400 ABL8BBU24200 ABL8BBU24400References battery 3,2AH (2) – ABL8BPK24A03 ABL8BPK24A037AH (2) – ABL8BPK24A07 ABL8BPK24A0712AH (2) – ABL8BPK24A12 ABL8BPK24A12(1) Battery module except 7AH and 12AH. For battery module 3.2AH with ABL1A02 kit.(2) Battery to be chosen according to the graph page 6/256Type of moduleRedundancy power supplies solutionsType of moduleStarter protection solution789CompatibilityConnection of 2 power supplies inputs ABL4... orABL8RP, ABL8WP up to 20 A (1 power supply 40A)Rated output voltage 24 VRated output current 40 ACertificationscCSAus, CB scheme, CEDimensions W x D x H (mm) 44 x 140 x 146Fixing (mm)DIN rail 35x7.5 ou 35x15ReferencesABL8RED24400CompatibilityRated output currentCalibresNumber of channels 4Diagnostic relayManual switch off (1 per channel)CertificationsOutput connection of Universal power suppliesABL8RPS24100..., ABL8RPM24200..., ABL8WPS24...,ABL4RSM24... and ABL4WSR24...10A par voie1 / 2.5 / 4 / 5 / 7 / 8 / 10 AYesTwo-polecCSAus, CB scheme, CEDimensions (mm) 71 x 109 x 110Fixing (mm)DIN rail 35x7.5 or 35x15 or on panel mount by screwReferencesABL8PRP24100106/4Other versions: please consult your Schneider Electric agency.


PhaseoPower suppliesRegulated switch mode. Panel mounting1Type of power supply60W to 240WInput voltage 85…264 VAC 85…132 VAC / 170…264 VACOutput voltage 12 VDC 24 VDC 24 VDCRated power / Rated output currrent 60 W / 5 A 100 W / 8.3 A 60 W / 2.5 A 100 W / 4.2 A 150 W / 6.2 A 240 W / 10 ACertificationsUL, c CSA us, CE, CtickDimensions W x D x H (mm) 150 x 38 x 98 200 x 38 x 98 150 x 38 x 98 200 x 38 x 98 200 x 50 x 98 200 x 65 x 98Fixing (mm) Panel mount by scew, by bracket ABL1A01 (1) , on DIN rail 35mm by panel ABL1A02 (1).References Without filter ABL1REM12050 – ABL1REM24025 ABL1REM24042 ABL1REM24062 ABL1REM24100With filter (2) – ABL1RPM12083 – ABL1RPM24042 ABL1RPM24062 ABL1RPM24100(1) has to order separately.(2) Anti harmonic IEC/EN 61000-3-223Filtered rectified45Type of power supply12W to 480W single-phaseInput voltage215/230/245 V or 385/400/415 VACRated output voltage24 VCertificationscULus, ENECRated power / Rated output current 12 W / 0.5 A 24 W / 1 A 48 W / 2 A 96 W / 4 A 144 W / 6 A 240 W / 10 A 360 W / 15 A 480 W / 20 ADimensions W x D x H (mm) 87 x 124 x 108 87 x 124 x 108 87 x 142 x 108 87 x 165 x 108 123 x 153 x 153 123 x 185 x 153 135 x 185 x 138 175 x 215 x 128Fixing (mm) DIN rail 35x7.5 or 35x15 or on panel mount by screw On panel mount by screwReferences ABL8FEQ24005 ABL8FEQ24010 ABL8FEQ24020 ABL8FEQ24040 ABL8FEQ24060 ABL8FEQ24100 ABL8FEQ24150 ABL8FEQ24200678Type of power supply240W to 1440W 3-phasesInput voltage3x 380 / 400 / 420 VRated output voltage24 VCertificationscULus, ENECRated power / Rated output current 240 W / 10 A 480 W / 20 A 720 W / 30 A 960 W / 40 A 1440 W / 60 ADimensions W x D x H (mm) 185 x 190 x 78 220 x 215 x 104 240 x 252 x 108 310 x 310 x 140 310 x 310 x 154Fixing (mm)On panel mount by screwReferences ABL8TEQ24100 ABL8TEQ24200 ABL8TEQ24300 ABL8TEQ24400 ABL8TEQ24600910Other versions: please consult your Schneider Electric agency.6/5


PhaseoTransformers1Type of transformerDouble winding operating temperature +60°C23Rated input voltage230/400 VAC (±15 V) 1-phaseCertifications c us, ENECRated power / Rated output currrent 25 VA 40 VA 63 VA 100 VA 160 VA 250 VA 320 VA 400 VA 630 VA 1000 VAVisualization LED display of voltage presenceat primary WithoutFixing (mm) DIN rail 35x15 or on panel mount by screw On panel mount by screwReferences ABT7PDU•••(1)Rated output voltage 24/48 V 002B 004B 006B 010B 016B 025B 032B 040B 063B 100B115/230 V 002G 004G 006G 010G 016G 025G 032G 040G 063G 100G(1) Complete the reference according to the power and voltage using the table below (example: ABL6TS02J)45Type of transformerSingle winding operating temperature +50°C67Rated input voltage230/400 VAC (±15 V) 1-phaseCertificationsRated output power 25 VA 40 VA 63 VA 100 VA 160 VA 250 VA 400 VA 630 VA 1000 VAFixing (mm)On panel mount by screwReferences ABL6TS•••(1)Rated output voltage 24 V 02B 04B 06B 10B 16B 25B 40B 63B 100B115 V 02G 04G 06G 10G 16G 25G 40G 63G 100G230 V 02U 04U 06U 10U 16U 25U 40U 63U 100U(1) Complete the reference according to the power and voltage using the table below (example: ABL6TS02J)89Type of transformerSingle winding operating temperature +40°C10Rated input voltage230 VAC (±15 V) 1-phaseCertificationsWithoutRated power / Rated output currrent 40 VA 63 VA 100 VA 160 VA 250 VA 320 VA 400 VAFixing (mm)On panel mount by screwReferences ABT7ESM•••(1)Rated output voltage 24 V 004B 006B 010B 016B 025B 032B 040B(1) Complete the reference according to the power and voltage using the table below (example: ABL6TS02J)6/6Other versions: please consult your Schneider Electric agency.


PhaseoNotes12345678910Other versions: please consult your Schneider Electric agency.6/7


AB1Terminal blocksSpring clamp technology1234Clip-on mounting on 35 mm rails Terminal blocks(sold in lots of 100)End covers(sold in lots of 100)Commoning link(sold in lots of 100)2.5 mm 2 c.s.a. Conducting AB1RRN235U2GR AB1RRNAC242GR AB1RRAL22 (1)Protective earth conductor AB1RRNTP235U2 AB1RRNTPAC242 –4 mm 2 c.s.a. Conducting AB1RRN435U2GR AB1RRNAC442GR AB1RRAL42 (1)Protective earth conductor AB1RRNTP435U2 AB1RRNTPAC442 –6 mm 2 c.s.a. Conducting AB1RRN635U2GR AB1RRNAC642GR AB1RRNAL62 (2)Protective earth conductor AB1RRNTP635U2 AB1RRNTPAC642 –10 mm 2 c.s.a. Conducting AB1RRN1035U2GR (3) AB1RRNAC1042GR AB1RRNAL102Protective earth conductor AB1RRNTP1035U2 (3) AB1RRNTPAC1042 –16 mm 2 c.s.a. Conducting AB1RRN1635U2GR (3) AB1RRNAC1642GR AB1RRNAL162Protective earth conductor AB1RRNTP1635U2 (3) AB1RRNTPAC1642 –35 mm 2 c.s.a. Conducting AB1RRN3535U2GR (4) – AB1RRAL352Protective earth conductor AB1RRNTP3535U2 (4) – –(1) For a 3, 4, 5 or 10-pole commoning link replace the last number of the reference (2) by 3, 4, 5 or 10 respectively. (Example: AB1RRAL22 becomes A1BRRAL23)(2) For a 3, 4, 5 or 10-pole commoning link replace the last number of the reference (2) by 3, 4, 5 or 10 respectively. (Example: AB1RRNAL62 becomes A1BRRNAL64)(3) Sold in lots of 50(4) Sold in lots of 10Screw clamp technology56789Clip-on mounting on 35 mm rails Terminal blocks End covers Commoning link(sold in lots of 100) (sold in lots of 100) (sold in lots of 100)2.5 mm 2 c.s.a. Conducting AB1VV235U AB1AC24 AB1ALN22 (1)Protective earth conductor AB1TP235U AB1AC25 –4 mm 2 c.s.a. Conducting AB1VV435U AB1AC24 AB1ALN42 (1)Protective earth conductor AB1TP435U – –6 mm 2 c.s.a. Conducting AB1VV635U AB1AC6 AB1ALN62 (1)Protective earth conductor AB1TP635U – –10 mm 2 c.s.a. Conducting AB1VVN1035U (2) AB1ACN10 AB1ALN102 (1)Protective earth conductor AB1TP1035U (2) – –16 mm 2 c.s.a. Conducting AB1VVN1635U (2) AB1ACN16 AB1ALN162 (1)Protective earth conductor AB1TP1635U (2) – –35 mm 2 c.s.a. Conducting AB1VVN3535U (3) _ AB1ALN352 (1)Protective earth conductor AB1TP3535U (3) – –70 mm 2 c.s.a. Conducting AB1VVN7035U (3) _ AB1ALN702150 mm 2 c.s.a. Conducting AB1VVN15035U (4) _ AB1ALN1502 (1)(1) For a 3, 4, 5 or 10-pole commoning link replace the last number of the reference (2) by 3, 4, 5 or 10 respectively. (Example: AB1ALN22 becomes AB1ALN23)(2) Sold in lots of 50(3) Sold in lots of 20Insulation displacement technology(2) Sold in lots of 1010Clip-on mounting on 35 mm rails 2-way terminal blocks End covers 2-pole commoning link (1)(sold in lots of 100) (sold in lots of 10) (sold in lots of 10)1 mm 2 c.s.a. Conducting AB1AA135U2GR AB1AAAC122GR AB1RRAL22Protective earth conductor AB1AATP135U2 AB1AAAC122VE –2.5 mm 2 c.s.a. Conducting AB1AA235U2GR AB1AAAC122GR AB1RRAL22Protective earth conductor AB1AATP235U2 AB1AAAC122VE –(1) For a 3, 4, 5 or 10-pole commoning link replace the last number of the reference (2) by 3, 4, 5 or 10 respectively. (Example: AB1RAL22 becomes AB1RAL23).6/8Other versions: please consult your Schneider Electric agency.


DZ5/AZ5Insulated cable endsConforming to DIN 46228 (1)mm 2 Øb Øb1 c0.5 3 1.4 130.75 3.1 1.6 131 3.4 1.8 13.51.5 4 2.1 13.52.5 4.6 2.7 14.5TypeSingle cable endsSold in lots of 10 x 100Packaging Individual or “strings” of bags Dispenser pack Strips of 50 in bagConductor c.s.a. 0.5 White DZ5CE005D AZ5CE005D DZ5CEB005Din mm 2 0.75 Grey DZ5CE007D AZ5CE007D DZ5CEB007D1 Red DZ5CE010D AZ5CE010D DZ5CEB010D1.5 Black DZ5CE015D AZ5CE015D DZ5CEB015D2.5 Blue DZ5CE025D AZ5CE025D DZ5CEB025D1234mm 2 Øb Øb1 c c10.75 2.8 x 5 1.8 15 81 3.4 x 5.4 2.05 15 81.5 3.6 x 6.6 2.3 15 82.5 4.2 x 7.8 2.9 18.5 10TypeDouble cable endsSold in lots of 5 x 100PackagingDispenser packConductor c.s.a. 2 x 0.75 Grey AZ5DE007Din mm 2 2 x 1 Red AZ5DE010D2 x 1.5 Black AZ5DE015D2 x 2.5 Blue AZ5DE025D(1) For insulated cable ends conforming to standard NF C 63-023 , please refer to your Schneider Electric agency.567Wiring accessories8TypePliers/cutters9Functions Stripping Cutting/stripping Crimping Crimping (ratchet) Cutting/stripping/crimping (2)For cable c.s.a. 0.08 to 4 mm 2 0.4 to 4 mm 2 0.5 to 16 mm 2 0.25 to 6 mm 2 0.5 to 2.5 mm 2References AT1PA7 AT2PE1 AT1PA2 AT2PA5 AT2TRIF01(2) For use with cable ends packed in strips of 50.10Other versions: please consult your Schneider Electric agency.6/9


Modicon I/O (ex Advantys)The compact dimensions and pre-wiredsystem characteristic of the Modicon I/Orange allow you to optimise installationtime, minimise costs and the risk of error,as well as simplify maintenance.From simple connectors to integratedI/O platforms, monobloc productsto modular solutions, Modicon I/Opresents an extensive range ofinterfaces and I/O for any application.


Interfaces and I/OThis document is a selection ofthe top selling products.1Distributed I/OIP20Expandable Block I/O, Modicon OTB ................................................................................... 7/2Modular I/O with device integration capabilities, Modicon STB ................................. 7/ 3 to 7/6IP67Block I/O, Modicon FTB ........................................................................................................ 7/7Modular I/O, Modicon FTM ................................................................................................... 7/8Distributed I/O with embedded controlInterfacesAccessories and CablingIP20Block I/O, Modicon Momentum ................................................................................ 7/9 to 7/12IP20Passive I/O sub-bases, Modicon ABE7 .............................................................................. 7/13Relay-based I/O sub-bases, Modicon ABE7 ....................................................................... 7/14Twido I/O sub-bases, Modicon ABE7 ................................................................................. 7/15IP67Embases E/S passives, Modicon ABE9 ............................................................................. 7/16Connection cables and jumper cables ..................................................................... 7/17 to 7/1923456789107/1


Modicon OTBIP 20 distributed I/O, optimised blockInterface modules12345Discrete Type of bus CANopen Ethernet TCP/IP Modbus SeriesMachine bus network (2) networkNumber of I/Os20 I/ONumber of inputs 12 inputs 24 VDC IEC type 1Number of outputs6 relay outputs and 2 solid state 24 VDC outputsConnection methodRemovable terminal blockNumber of I/O expansion modules (1)7 discrete or analogue input/output modules, or connection accessoriesMaximum I/O configurationWith interface module base: 132 with screw terminal I/O expansion;244 with HE10 connector I/O expansion; up to 48 analogue channelsSupply voltage24 VDCCounting 5 kHz 2 channels, 32 bits (0…4 294 967 295 points)dedicated discrete inputs -up counting/down counting with preset20 kHz 2 channels, 32 bits (0…4 294 967 295 points)up/down counting, up counting, down counting, frequency meterPulse generator, 7 kHz2 PWM function channels (output with pulse width modulation)or PLS function (pulse generator output)Dimensions W x D x H (mm) 55 x 70 x 90References OTB1C0DM9LP OTB1E0DM9LP OTB1S0DM9LP(1) for the references of discrete I/O and analogue expansion modules, refer to the Twido or Modicon OTB catalogue(2) Transparent Ready : Class A1067AccessoriesType of accessory Commoning modules Documentation8UsageFor grouping input oroutput commons, max 8 AUser guides for Modicon hardware and software,and Modicon Configuration Software for ModiconOTB/FTB/FTM. Provided on CD.Positioning Inter-module –Référence OTB9ZZ61JP FTXES019107/2Other versions: please consult our Customer Care Centre.


Modicon STBIP 20 Distributed I/O, modular systemCommunication modules1Type of module NIMEtherNetModbus TCP Modbus TCP, dual port EtherNet/IPBaud rate 10 Mbps 10/100 Mbps 10/100 MbpsTransparent Ready Class B20 B15 N/AEmbedded Web server Standard services Standard services Standard servicesEthernet servicesSNMP agent, FDR, BootP& DHCP clientSNMP agent, RSTP, BootP& DHCP clientSNMP agent, BootP & DHCP clientMax. number of addressable I/O modules 32 per island 32 per island 32 per islandDimensions W x D x H (mm) 40 x 70 x 128.3 40 x 70 x 128.3 40 x 70 x 128.3Reference Standard STBNIP2212 STBNIP2311 STBNIC2212234Type of module NIM Machine bus FieldbusCANopen Fipio INTERBUS Profibus DPMax. number of addressable I/O modules 32 per island (1) (2) 32 per island (1) 32 per island (1) (2) 32 per island (1) (2)Baud rate 10 K…1 Mbps 1 Mbps 0.5 Mbps 9.6 K…12 MbpsDimensions W x D x H (mm) 40 x 70 x 128.3Reference Standard STBNCO2212 STBNFP2212 STBNIB2212 STBNDP2212Basic STBNCO1010 – STBNIB1010 STBNDP1010(1) On 1 primary segment and 6 expansion segments max.(2) 12 max on 1 primary segment for basic versions.567Type of moduleOther networksModbus PlusDeviceNetMax. number of addressable I/O modules 32 per island 32 per island 12 per islandBaud rate 1 Mbps 125, 250 or 500 Kbps 125, 250 or 500 KbpsDimensions W x D x H (mm) 40 x 70 x 128.3Reference Standard STBNMP2212 STBNDN2212 –Basic – – STBNDN1010Type of accessoryConnection accessoriesRemovable terminals for24 VDC power supply DeviceNetUse All communication modules Network link DeviceNet moduleReference Screw terminals STBXTS1120 (1) STBXTS1111Spring terminals STBXTS2120 (1) STBXTS2111(1) To be ordered separately, sold in lots of 10 only for spares parts.(STBXTSp120 are delivered systematicaly with STBNpppppp)Marking label sheetsSTBXMP6700ScrewdriverSTBXTT02208910Connection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.7/3


Modicon STBIP 20 Distributed I/O, modular systemPower distribution modules (1)1234Type of module PDM AuxiliaryPower supplyConnection by removable terminals Screw STBXTS1130 (2) (3) Screw STBXTS1120 (2)Spring STBXTS2130 (2) (3) Spring STBXTS2120 (2)Supply voltage 24 VDC 115…230 VAC 24 VDCMaximum current Inputs (4) 4 A at 30°C, 2.5 A at 60°C – 5 A at 30°C, 2.5 A at 60°C – –Outputs (4) 8 A at 30°C, 5 A at 60°C – 10 A at 30°C, 5 A at 60°C – –Inputs/Outputs (4) – 4 A at 30°C, 2.5 A at 60°C – 4 A at 30°C, 2.5 A at 60°C –Logic internal 5 V – – – – 1.2 ASensor/actuator bus voltage range 19.2…30 VDC 85…265 VAC –Dimensions W x D x H (mm) 18.4 x 70 x 128.3Reference Module (5) Standard STBPDT3100K – STBPDT2100K – STBCPS2111KBasic – STBPDT3105K – STBPDT2105KBase STBXBA2200 STBXBA2200 STBXBA2100(1) Process power supplies see chapter 6 “Power supply”(2) To be ordered separately, sold in lots of 10.Bus extension modules for standard range(3) PDM connector keying pin kit STBXMP7810.(4) PDM fuse kit STBXMP5600.(5) Kit reference including module, base and terminal567Type of module “EOS” “BOS” Extension for CANopenEnd of segment Beginning of segment connection devicesConnection by removable terminals – Screw STBXTS1120 (1) Screw STBXTS1110 (2)– Spring STBXTS2120 (1) Spring STBXTS2110 (2)Use For placing at end of segment For placing at head of each For placing at end of last(except for the last) extension segment segmentDimensions W x D x H (mm) 18.4 x 70 x 128.3Reference Module (3) Standard STBXBE1100K STBXBE1300K STBXBE2100KBase STBXBA2300K STBXBA2400 STBXBA2000(1) To be ordered separately, sold in lots of 10. (2) To be ordered separately, sold in lots of 20.(3) Kit reference including module, base and terminalSoftware and memory card8910Type Modicon STB, OTB, FTM, FTB configuration software Removable(PC connection cable supplied)memory cardSoftware User Guide Single station 3 pack 10 pack Unlimited Site System Aliance –IntegratorMemory size – 32 KBReference STBSPU1000 STBSPU1003 STBSPU1011 STBSPU1130 STBSPU1010 STBXMP4440Hardware User GuideSTBSUS8800Type of accessoryConnection accessoriesIsland bus expansion cableLength 0.3 m 1 m 4.5 m 10 m 14 mReference STBXCA1001 STBXCA1002 STBXCA1003 STBXCA1004 STBXCA1006Bus termination module or plug Programmation connection cable L= 2 mReference STBXMP1100 STBXCA4002Connection accessories: See www.schneider-electric.com7/4Other versions: please consult our Customer Care Centre.


Discrete modules1Type of moduleDiscrete inputsConnection by removable terminals (1) Screw (2) STBXTS1100 STBXTS1180 STBXTS1110Spring (2) STBXTS2100 STBXTS2180 STBXTS2110Number of channels 2 4 6 16 2 2 (isolated) 2Input voltage 24 VDC 115 VAC 230 VACDimensions W x D x H (mm) 13.9 x 70 x 128.3 18.4 x 70 x 128.3Reference Module (6) Standard STBDDI3230K STBDDI3420K STBDDI3610K – STBDAI5230K STBDAI5260K STBDAI7220KBasic – STBDDI3425K STBDDI3615K STBDDI3725KS/KC* – – –STBDDI3725**Base (3) STBXBA1000 STBXBA3000 STBXBA2000* KS with base and screw terminals,KC with base and spring terminals** Without base and terminal234Type of moduleDiscrete solid state outputsConnection by removable terminals (1) Screw (2) STBXTS1100 STBXTS1180Spring (2) STBXTS2100 STBXTS2100Number of channels 2 4 6 16Output voltage 24 VDC 24 VDC 24 VDC 24 VDCOutput current 0.5 A 2 A 0.25 A 0.5 A 0.25 A 0.5 A 0.5 ADimensions W x D x H (mm) 13.9 x 70 x 128.3Reference Module (6) Standard STBDDO3200K STBDDO3230K – STBDDO3410K – STBDDO3600K –Basic – – STBDDO3415K – STBDDO3605K – STBDDO3705KS/KC*STBDDO3705**Base (3) STBXBA1000 STBXBA3000* KS with base and screw terminals,KC with base and spring terminals** Without base and terminal567Type of moduleDiscrete outputsTriacRelayConnection by removable terminals (1) Screw (2) STBXTS1100Spring (2) STBXTS2100Number of channels 2 2 (isolated) 2 NO/NC and common 2NC+NOOutput voltage 115…230 VAC 115 VAC 24 VDC ou 115…230 VACOutput current 2 A à 30°C, 1 A à 60°C 2 A per contact 7 A per contactDimensions W x D x H (mm) 18.4 x 70 x 128.3 28.1 x 70 x 128.3Reference Module (6) Standard STBDAO8210K STBDAO5260K STBDRC3210K STBDRA3290KBase (3) STBXBA2000 STBXBA3000(1) To be ordered separately, sold in lots of 20.(2) I/O connector keying pin kit STBXMP7800(3) Module keying pin kit STBXMP7700(4) if connection on Telefast2 order STBXTS6510 or connection on Telefast Twido order STBXTS5510(5) if connection on Telefast2 order STBXTS6610 or connection on Telefast Twido order STBXTS5610(6) Kit reference including module, base and terminalConnection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.7/58910


Modicon STBIP 20 Distributed I/O, modular systemAnalog modules1Type of module (1) Analog inputs (*)23Connection by removable terminals Screw STBXTS1100 (2) / Spring STBXTS2100 (2)Number of channels 2 4 8 2Input signal - 10…+10 V 0…+10 V 0…20 mA 4…20 mA 4…20 / 0…20 mA Selectable Selectable Multirange (3)Resolution 11 bits + sign 10 bits 12 bits 10 bits 15 bits + signDimensions W x D x H (mm) 13.9 x 70 x 128.3 18.4 x 70 x 128.3 13.9 x 70 x 128.3Reference Module (8)– – STBACI1230K – STBACI0320K STBAVI0300K STBACI1400K (5) STBART0200KStandardSTBAVI1270K – – – STBACI8320K (4) – STBAVI1400K (6) –Basic – STBAVI1255K – STBACI1225K – – – –Base STBXBA1000 STBXBA2000 STBXBA1000(*) For other references, see catalogue orvisit our website: www.schneider-electric.com456Type of module (1)Analog outputsConnection by removable terminals Screw STBXTS1100 (2) / Spring STBXTS2100 (2)Number of channels 1 2Output signal 4…20 mA 0…+10 , - 10…+10 V 0…+10 V -10 V…+10 V 0…20 mA 4…20 mA 4…20 mA Selectable (6)Resolution 15 bits + sign 11 bits + sign or 12 bits 10 bits 9 bits + sign 12 bits 10 bits 15 bits + signDimensions W x D x H (mm) 18.4 x 70 x 128.3 13.9 x 70 x 128.3 18.4 x 70 x 128.3Reference Module (8) Standard STBACO0120K STBAVO1250K – – STBACO1210K – STBACO0220K STBAVO0200KBasic – – STBAVO1255K STBAVO1265K – STBACO1225K – –Base STBXBA2000 STBXBA1000 STBXBA2000Application-specific modules78910Type of module (1)For motor startersTeSys model UCounterConnection by connector 4 RJ45 Spring STBXTS2150 (2)Number of inputs/outputs 12 I / 8 O 4 I / 2 OInput voltage 24 VDC 24 VDCOutput voltage/current 24 VDC/0.1 A per channel 24 VDC/0.5 ANumber of channels 4 starters-controllers 1 counter channel 40 kHzDimensions W x D x H (mm) 28.1 x 70 x 128.3Reference Module (8) Standard STBEPI2145K STBEHC3020KBaseSTBXBA3000Connection cables (7) –(1) Grounding kit (conseilled for counter > 40 kHz): STB<strong>XS</strong>P3000 (connecting support) + STB<strong>XS</strong>P3010 (1.5…6 mm 2 cables) + STB<strong>XS</strong>P3020 (5…11 mm 2 cables)(2) To be ordered separately, sold in lots of 20.(3) Multirange temperature probe thermocouples B, E, J, K, R, S, T. Thermal probe Pt 100, Pt 1000, Ni 100, Ni 1000, cu 10, ± 80 mV.(4) 4 HART-tolerant channels (5) Input signal selectable / channel 0…20 mA and 4…20 mA (6) Input signal selectable / channel 1…5 VDC, 0…5 VDC, 0…10 VDC, ± 5 VDC and ± 10 VDC(7) LU9R03 (0,3 m), LU9R10 (1 m), 490NTW00002 (2 m), LU9R30 (3 m), 490NTW00005 (5 m), 490NTW00012 (12 m)(8) Kit reference including module, base and terminal7/6Other versions: please consult our Customer Care Centre.


Modicon FTBIP 67 distributed I/O, optimised blockInterface modules, plastic enclosure1Type of moduleCANopenmachine busDeviceNetFieldbusProfiBusFieldbusInterBusFieldbusNumber of channels 16Type of female connectorM12, 5-pinMax. voltage / current of inputs24 VDC type 2/200 mAMax. voltage / current of outputs24 VDC/1.6 AMax. current per splitter box8 AProduct certificationcULusDimensions W x D x H (mm) 63 x 50.5 x 220 63 x 69 x 220Diagnostics Splitter boxes By LED for: bus and I/O undervoltage + I/O short-circuit + I/O power supplyChannelsBy LED for: I/O short-circuit + wire breakage fault + I/O faultReferences 16 inputs FTB1CN16EP0 FTB1DN16EP0 FTB1DP16EP0 FTB1IB16EP08 inputs/8 outputs FTB1CN08E08SP0 FTB1DN08E08SP0 FTB1DP08E08SP0 FTB1IB08E08SP012 inputs/4 outputs FTB1CN12E04SP0 FTB1DN12E04SP0 FTB1DP12E04SP0 FTB1IB12E04SP016 configurable inputs/outputs FTB1CN16CP0 FTB1DN16CP0 FTB1DP16CP0 FTB1IB16CP0234Interface modules, metal enclosure567Type of module CANopen DeviceNet ProfiBusNumber of channels 8Type of female connectorM12, 5-pinMax. voltage / current of inputs24 VDC type 2/200 mAMax. voltage / current of outputs24 VDC/1.6 AMax. current per splitter box8 AProduct certificationcULusDimensions W x D x H (mm) 62.7 x 38.9 x 224.7Diagnostics Splitter boxes By LED for: bus and I/O undervoltage + I/O short-circuit + I/O power supplyChannelsBy LED for: I/O short-circuit + wire breakage fault + I/O faultReferences 16 inputs FTB1CN16EM0 FTB1DN16EM0 FTB1DP16EM08 inputs/8 outputs/configurable outputs FTB1CN08E08CM0 FTB1DN08E08CM0 FTB1DP08E08CM016 configurable inputs/outputs FTB1CN16CM0 FTB1DN16CM0 FTB1DP16CM08910Other versions: please consult our Customer Care Centre.7/7


Modicon FTMIP 67 distributed I/O, modular systemInterface modules123Type of bus moduleCANopenmachine busDeviceNetfieldbusProfibusfieldbusMax. number of Discrete I/O 256Max. number of splitter boxes 16Bus module supply voltage24 V DCBus module max. supply current9 AProduct certification UL/CSA CULusDimensions W x D x H (mm) 50 x 50.3 x 151References FTM1CN10 FTM1DN10 FTM1DP10Splitter boxes4567Type of splitter boxDiscrete inputs/outputsCompactExpandableInput voltage 24 V DC/type 2/200 mA 24 V DC/type 2/200 mAOutput voltage 24 V DC 24 V DCType of output Solid-state Solid-stateOutput current 0.5 A 0.5 AMaximum supply current by internal bus 4 A 4 ADiagnosticsShort-circuit on I/O, wire breakage fault, sensor/actuator faultDimensions W x D x H (mm) 30 x 34.5 x 126 30 x 34.5 x 151I/O connection M8 connector M12 connector M8 connector M12 connectorReferences 8 inputs FTM1DE08C08 FTM1DE08C12 FTM1DE08C08E FTM1DE08C12E8 configurable inputs/outputs FTM1DD08C08 FTM1DD08C12 FTM1DD08C08E FTM1DD08C12E16 inputs – FTM1DE16C12 (1) – FTM1DE16C12E (1)16 configurable inputs/outputs – FTM1DD16C12 (1) – FTM1DD16C12E (1)(1) Dimensions: 50 x 34.5 x 126 .8910Type of splitter boxAnalogue inputs/outputsCompactType of inputs/outputs Current VoltageMeasuring range 0…20 mA/4…20 mA ± 10 V DC/0…10 V DCDiagnosticsShort-circuit on I/O, wire breakage fault, sensor/actuator faultConversion time≤ 2 ms per channelDimensions W x D x H (mm) 30 x 34.5 x 126Resolution 16 bit 12 bit 15 bit + sign 11 bit + signReferences 4 inputs FTM1AE04C12C – FTM1AE04C12T –4 outputs – FTM1AS04C12C – FTM1AS04C12T7/8Other versions: please consult our Customer Care Centre.


Modicon MomentumDistributed I/O and processorsDiscrete I/O modules1Type of moduleMultibus discrete inputsConnectionBy screw terminals 170XTS00100 or spring terminals 170XTS00200 (to be ordered separately)Input voltage 24 VDC 120 VAC 230 VACNumber of channels 16 (1 common point) 32 (2 common points) 16 (2 common points)Dimensions W x D x H (mm)125 x 47.5 x 141.5 (with communication modules or processors)144 x 70 x 141.5 (with M1/M1E processors and optional modules)Reference 170ADI34000 170ADI35000 170ADI54050 170ADI74050234Type of moduleMultibus discrete outputsSolid stateTriacConnectionBy screw terminals 170XTS00100 or spring terminals 170XTS00200 (to be ordered separately)Output voltage 24 VDC 120 VAC 230 VACNumber of protected channels 16 32 8 16 8 16(2 common pts) (2 common pts) (2 common pts) (2 common pts) (2 common pts) (2 common pts)Output current Per channel 0,5 A 0,5 A 2 A 0,5 A 2 A 0,5 APer group of channels 4 A 8 A 4 A 4 A 4 A 4 APer module 8 A 16 A 8 A 8 A 8 A 8 ADimensions W x D x H (mm)125 x 47.5 x 141.5 (with communication modules or processors)144 x 70 x 141.5 (with M1/M1E processors and optional modules)Reference 170ADO34000 170ADO35000 170ADO53050 170ADO54050 170ADO73050 170ADO74050567Type of moduleMultibus discrete I/OSolid state Relay TriacConnectionBy screw terminals 170XTS00100 or spring terminals 170XTS00200 (to be ordered separately)Number of channels Inputs 16 (1 common pt) 16 (4 com. pts) 16 (1 com. pt) 10 (1 common pt)Input logic Positive Positive (2) Negative Positive –Outputs 16 (1 common pt) 16 (2 common pts) 8/4 (1 com. pt) 12 8 (2 common pts) 8 (1 com. pt)Input voltage 12…48 VDC 24 VDC 120 VACOutput voltage 12…48 VDC 24 VDC 24…230 VAC/20…115 VDC 120 VACOutput current Per output 0,5 A 0,5 A 2 A 0,5 A 2 A 0,5 APer group of channels – 4 A 4 A 4/2 A 8 A 4 APer module 8 A 8 A 8 A 6 A 16 A 4 ADimensions W x D x H (mm)125 x 47.5 x 141.5 (with communication modules or processors)144 x 70 x 141.5 (with M1/M1E processors and optional modules)Reference 170ADM85010 170ADM35010 170ADM35015 170ADM37010 170ADM39010 170ADM39030 170ARM37030 170ADM69051(2) For a version with high-speed positive logic, replace 0 at the end of the reference with 1. E.g. 170ADM35010 becomes 170ADM350118910Connection accessories: See www.schneider-electric.comOther versions: please consult our Customer Care Centre.7/9


Modicon MomentumDistributed I/O and processorsAnalog I/O modules1Type of moduleMultibus analog inputs23ConnectionBy screw terminals 170XTS00100 or spring terminals 170XTS00200 (to be ordered separately)Number of channels 8 isolated 16 with common point 4 isolatedInput signal ± 5 V, ± 10 V, ± 20 mA, ± 5 V, ± 10 V, 4...20 mA Multi-range ± 25 mV, ± 10 mV1…5 V, 4…20 mA (1)Resolution 14 bits + sign, 15 bits unipolar 12 bits + sign 15 bits + signDimensions W x D x H (mm)125 x 47.5 x 141.5 (with communication modules or processors)144 x 70 x 141.5 (with M1/M1E processors and optional modules)Reference 170AAI03000 170AAI14000 170AAI52040(1) Temperature probe: Pt 100, Pt 1000, Ni 100, Ni 1000, Thermocouple: B, E, J, K, N, R, S, T.4567Type of module Multibus analog outputs Analog I/O andmultibus discrete I/OConnectionBy screw terminals 170XTS00100 or spring terminals 170XTS00200 (to be ordered separately)Number of channels Inputs – 4 differential + 4 discrete 6 with com pt + 8 discrete (24 VDC)Outputs 4 2 + 2 discrete (24VDC) 2 + 2 discrete (12VDC) 4 with com pt + 8 discrete (24 VDC)Input signal ± 10 V, 0...20 mA ± 10 V, 4...20 mA ± 5 V, ± 10 V, ± 20 mA,0…10 V ± 10 V1…5 V, 4…20 mAOutput signal – ± 10 V, 4...20 mA 0…10 V ± 10 VResolution 12 bits + sign 12...14 bits dep. on signal 14 bits 14 bitsDimensions W x D x H (mm)125 x 47.5 x 141.5 (with communication modules or processors)144 x 70 x 141.5 (with M1/M1E processors and optional modules)Reference 170AAO12000 170AAO92100 170AMM09000 170AMM09001 170ANR12090 170ANR12091Application-specific I/O modules8910Type of module High-speed counter Discrete I/Owith Modbus portConnectionBy screw terminals 170XTS00100 or spring terminals 170XTS00200 (to be ordered separately)Type of inputs for Incremental or absolute encoders RS 485 Modbus portOperating voltage 24 VDC 120 VACCounting frequency 200 kHz –Number of channels 2 independent –Number of discrete I/O 2 x 3 inputs/2 x 2 outputs 6 inputs/3 outputsDimensions W x D x H (mm)125 x 47.5 x 141.5 (with communication modules or M1/M1E processors)144 x 70 x 141.5 (with M1/M1E processors and optional modules)Reference 170AEC92000 170ADM540807/10Other versions: please consult our Customer Care Centre.


Modicon MomentumDistributed I/O and processorsCommunication modules1Type of module Ethernet Fipio INTERBUS (1) Profibus DPTCP/IP network fieldbus fieldbus fieldbusSpeed 10 Mbps 10/100 Mbps 1 Mbps 0.5 Mbps 9.6 K…12 MbpsManager PLC – Premium - -Redundancy No No No NoStandard services Modbus TCP/IP – – –Reference 170ENT11002 170ENT11001 170FNT11001 170INT11000 (1) 170DNT11000(1) Generation 4, twisted pair medium: 170INT11003, with optical fiber medium: 170INT1200023Type of moduleOther networksModbus PlusDeviceNetSpeed 1 Mbps 0.5 MbpsManager PLC Premium or Quantum Quantum –Redundancy No Yes NoStandard services – – –Reference 170PNT11020 170PNT16020 170LNT71000Optional modules for M1/M1E processors45Type of module (2) Modbus Plus Asynchronous serial linkCommunication ports 1 Modbus Plus 2 redundant Modbus Plus RJ45Real-time clockIntegrated, ± 13 sec/day accuracyConnectionBy 9-way SUB-D connectorReference 172PNN21022 172PNN26022 172JNN21032(2) Include save battery of the M1/M1E processors application and data memories.Connection accessoriesTypeRS 232C communication cable67Length 1 m 3 m 6 mReference 110XCA28201 110XCA28202 110XCA282038Power supply module (3)9Type of power supply module forMomentum processorsInput voltage120 or 230 VAC (selected by jumper)Output voltage24 VDCOutput current0.7 ADimensions W x D x H (mm) 73 x 44.5 x 146Reference170CPS11100(3) Process power supplies see chapter 6 “Power supply”10Other versions: please consult our Customer Care Centre.7/11


Modicon MomentumDistributed I/O and processorsM1/M1E processors1Type of processorM1234Number of I/O Discrete 2048 I/O 2048 I/2048 Q 8192 I/ORegisters 2048 words 4096 words 26048 wordsIntegrated communication ports Modbus 1 RS 232C 1 RS 232C + 1 RS 485 1 RS 232C 1 RS 232C + 1 RS 485Ethernet TCP/IP –I/O bus (1) – 1 I/O port –Transparent Ready Embedded Web server –Memory capacity RAM 64 Kb 256 Kb 512 KbFlash 256 Kb 256 Kb 512 KbUser, 984 LL language (2) 2.4 K 12 K 18 KUser, IEC language (3) – 160 K 240 KData 2 K 4 K 24 KCycle time 1 ms/K 1 ms/K 0.63 ms/K 1 ms/KReference 171CCS70000 171CCS78000 171CCS76000 171CCC78010(1) I/O bus derived from INTERBUS bus.(2) ProWORX 32 or Concept programming software.(3) Concept programming software.5Type of processor M1 M1E67Number of I/O Discrete 8192 I/ORegisters26048 wordsIntegrated communication ports Modbus 1 RS 232C 1 RS 485 –Ethernet TCP/IP – 1 integrated Ethernet portI/O bus (1) 1 I/O port – 1 I/O portTransparent Ready Embedded Web server – Standard services (class A10)Memory capacity RAM 512 Kb 544 KbFlash 512 Kb 1 Mb 512 Kb 1 MbUser, 984 LL language (2)18 KUser, IEC language (3) 240 K – 200 K – 200 KData24 KCycle time 1 ms/K 0.3 ms/KReference 171CCC76010 171CCC98020 171CCC98030 171CCC96020 171CCC960308910Type of processor171 CBB97030Integrated communication ports Modbus 1 RS 232/485Ethernet TCP/IP4 integrated Ethernet portTransparent Ready Embedded Web server Standard services (class B)Memory capacity RAM 512 KbFlash1 MbUser, 984 LL language (2)18 KUser, IEC language (3)200 KData24 KCycle time0.25 ms/KReference171CBB97030Connection accessories: See www.schneider-electric.com7/12Other versions: please consult our Customer Care Centre.


Modicon ABE7Telefast pre-wired system – IP20 sub-basesPassive I/O sub-bases «Discrete»1Type of connection sub-baseOptimumNumber of channels 16 16Max. current per channel 0.5 A 0.5 AControl voltage / output voltage 24 VDC / 24 VDC 24 VDC / 24 VDCLED per channel – WithNumber of terminals per channel/on row number 1/2 1/1 2/2 3/3Dimensions W x D x H (mm) 55 x 59 x 67 106 x 60 x 49References – ABE7H16C11 ABE7H16C21 ABE7H16C31Cable L = 1 m ABE7H20E100 (1) – – –Cable L = 2 m ABE7H20E200 (1) – – –Cable L = 3 m ABE7H20E300 (1) – – –Connection cable recommended for Modicon, TSX Micro and Premium PLCs, L = 1 m (2) ABFH20H100(1) Connection cable supplied for PLCs.(2) For a 2 m length cable, replace the number 1 in the reference by 2, and for a 3 m length, by 3. (Example: ABFH20H100 becomes ABFH20H200).2345Type of connection sub-baseUniversalNumber of channels 16Max. current per channel0.5 AControl voltage / output voltage24 VDC / 24 VDCLED per channel – With – – With WithNumber of terminals per channel/on row number 1/1 1/1 1/2 2/2 2/2 3/3Dimensions W x D x H (mm) 125 x 58 x 70 84 x 58 x 70 125 x 58 x 70References ABE7H16R10 ABE7H16R11 ABE7H16R50 ABE7H16R20 ABE7H16R21 ABE7H16R31Connection cable recommended for Modicon, TSX Micro and Premium PLCs, L = 1 m: ABFH20H100 (2)(2) For a 2 m length cable, replace the number 1 in the reference by 2, and for a 3 m length, by 3. (Example: ABFH20H100 becomes ABFH20H200).678Type of connection sub-base For counter and Passive distribution Distribution and supplyanalogue channels with shielding continuity of analogue channelsNumber of channels 1 counter channel (3) 8 8Max. current per channel 25 mA 25 mA 25 mAControl voltage / output voltage24 VDC / 24 VDCNumber of terminals per channel 2 2 or 4 2 or 4Dimensions W x D x H (mm) 143 x 58 x 70 125 x 58 x 70 125 x 58 x 70References ABE7CPA01 ABE7CPA02 ABE7CPA03Connection cable recommendedTSX Micro L = 2.5 m TSXCCPS15 – –for Modicon PLCs (4)Premium L = 3 m TSXCAP030(3) Or 8 inputs + 2 outputs, analogue .(4) Connection cables available for other PLCs, please refer to your Schneider Electric agency.Other versions: please consult our Customer Care Centre.7/13910


Modicon ABE7Telefast pre-wired system – IP20 sub-basesSockets with plug-in relays and terminals1234Type of connection sub-baseWith soldered solid-state With soldered solid-state With soldered electrorelayinputsrelay outputsmechanical relay outputsNumber of channels 16 16 16Max. current per channel 12 mA 0.5 A 2 A 5 AInput voltage / output voltage 24 VDC / - 110 VAC / - - / 24 VDC - / 5…30 VDC, 250 VACNumber of contacts – – 1 N/OPolarity distribution – – (1) Volt-freeNumber of terminals per channel 2Dimensions W x D x H (mm) 206 x 58 x 77References ABE7S16E2B1 ABE7S16E2F0 ABE7S16S2B0(2) ABE7S16S1B2 ABE7R16S111 ABE7R16S210Connection cable recommended for Modicon, TSX Micro and Premium PLCs, L = 1 m: ABFH20H100 (3)(1) Contact common per group of 8 channels.(2) With fault detection signal (can only be used with modules with protected outputs).(3) For a 2 m length cable, replace the number 1 in the reference by 2, and for a 3 m length, by 3. (Example: ABFH20H100 becomesABFH20H200).5Type of connection sub-baseWith plug-in electromechanical relays67Number of channels 16Max. current per channel 5 A 2.5 A 4 A 5 AControl voltage / output voltage24 VDC / 5…24 VDC, 230 VACNumber of contacts 1 N/O 1 C/O 2 C/OPolarity distribution (4) (5) Volt-freeNumber of terminals per channel 2 2 or 3 2 to 6Dimensions W x D x H (mm) 110 x 54 x 89 211 x 64 x 89 272 x 74 x 89References ABE7R16T111 ABE7R16T212 ABE7R16T210 ABE7R16T230 ABE7R16T330 ABE7R16T370Connection cable recommended for Modicon, TSX Micro and Premium PLCs, L = 1 m: ABFH20H100 (6)(4) Contact common per group of 4 channels.(5) Common on both poles.(6) For a 2 m length cable, replace the number 1 in the reference by 2, and for a 3 m length, by 3. (Example: ABFH20H100 becomes ABFH20H200).8Connection cables for PLCs (7)9Input/Output functions Discrete Analogue Analogueand counterCounterAxis control10References Cable L = 1 m ABFH20H100 – – – –Cable L = 2 m ABFH20H200 ABFY25S200 – – TSXCXP213Cable L = 2.5 m – – TSXCCPS15 TSXCCPH15 –Cable L = 3 m ABFH20H300 TSXCAP030 – – –Cable L = 6 m – – – – TSXCXP613(7) Modicon, TSX Micro and Premium PLCs.For other connection cables and accessories, please refer to your Schneider Electric agency.7/14Other versions: please consult our Customer Care Centre.


Modicon ABE7Connection interfacesSub-bases for input/output module1Type of connection sub-baseDiscrete outputsRelayNumber of channels 16 16 16 16Type of outputs 16 I 16 O 16 O, fuse protected 16 O(1 common for 16 channels) (1 common for 16 channels) (1 common for 16 channels) (1 common for 4 channels)Voltage / current of outputs 24 VDC / 5 mA 24 VDC / 0.1 A Relay: 5…30 VDC, 250 VAC / 3 ALED per channel – With –Number of terminals per channel/row number 2/2Dimensions W x D x H (mm) 106 x 60 x 49 130 x 62.5 x 83References ABE7E16EPN20 ABE7E16SPN20 ABE7E16SPN22 ABE7E16SRM2023Connection cables for Twido45Type of cableFor linking Twido and Telefast sub-baseFor use with TWDLMDA20DTK/40DTK TWDDI16DK/32DK/DDO16TK/32TKType of connectors HE10, 26-pin, at either end HE10, 20-pin, at either endReferences Cable L = 0.5 m ABFT26B050 ABFT20E050L = 1 m ABFT26B100 ABFT20E100L = 2 m ABFT26B200 ABFT20E2006Type of accessoryAccessoriesOptional clip-in terminals7Number of linked terminals 20 12 + 8References ABE7BV20 ABE7BV20TB8910Other versions: please consult our Customer Care Centre.7/15


Modicon ABE9Telefast pre-wired systemIP67 passive splitters boxes1Type of connectionTo PLC using multicore cable234Number of channels 4 8Type of female connector M12, 5-pin M12, 5-pinMax. number of signals 8 16Max. current per channel4 AMax. current per splitter box 16 A (1 mm 2 )Product certificationcULusDimensions W x D x H (mm) 50.2 x 42 x 92.2 50.2 x 42 x 149.2References Without LEDs Cable L = 5 m ABE9C1240L05 ABE9C1280L05Cable L = 10 m ABE9C1240L10 ABE9C1280L10With LEDs (1) Cable L = 5 m ABE9C1241L05 ABE9C1281L05Cable L = 10 m ABE9C1241L10 ABE9C1281L10(1) Green LED: power supply status, yellow LED: channel status.5Type of connectionTo PLC using M23 connector67Number of channels 4 8Type of female connector M12, 5-pin M12, 5-pinMax. number of signals 8 16Max. current per channel 4 AMax. current per splitter box16 AProduct certificationcULusDimensions, W X D x H 50.2 x 36.5 x 92.2 50.2 x 36.5 x 149.2References Without LEDs ABE9C1240C23 ABE9C1280C23With LEDs (1) ABE9C1241C23 ABE9C1281C23(1) Green LED: power supply status, yellow LED: channel status.8Accessories910Type of accessory Splitter boxes w/o cable Terminal connectors Sealing plugsWithout LEDs With LEDs Cable L = 5 m Cable L = 10 m (sold in lots of 10)References 4-channel ABE9C1240M ABE9C1241M ABE9XCA1405 ABE9XCA1410 –8-channel ABE9C1280M ABE9C1281M ABE9XCA1805 ABE9XCA1810 –for Ø12 connector – – – – FTXCM12B7/16Other versions: please consult our Customer Care Centre.


ModiconAccessories for distributed I/O FTM (1)Internal bus connection cables1(1) For sensor/actuator cabling accessories, see page 7/13Type of cableFor linking bus module and splitter boxesType of connectorElbowed M12, 6-pin, at either endReferences Cable L = 0.3 m FTXCB3203L = 0.6 mFTXCB3206L = 1 mFTXCB3210L = 2 mFTXCB3220L = 3 mFTXCB3230L = 5 mFTXCB325023Auxiliary power supply connection cables4Type of cableFor connection of 24 V DC auxiliary power supply5Type of connector Elbowed M12, 6-pin, at either end Elbowed M12, 6-pin, at one end (other end free)References Cable L = 0.3 m FTXCA3203 FTXCA3103L = 0.6 m FTXCA3206 FTXCA3106L = 1 m FTXCA3210 FTXCA3110L = 2 m FTXCA3220 FTXCA3120L = 3 m FTXCA3230 FTXCA3130L = 5 m FTXCA3250 FTXCA315067Accessories8TypeLine terminator for end of internal bus9Type of connectorReferencesM12FTXCBTL1210Other versions: please consult our Customer Care Centre.7/17


ModiconAccessories for distributed I/O FTB/FTM (1)Bus connection cables123(1) For sensor and actuator cabling accessories:see page 7/17Type of bus CANopen DeviceNet ProfiBus INTERBUSmachine bus fieldbus fieldbus fieldbusType of female connector M12, 5-pin, at either end –Connector coding A encoded B encoded –References Cable L = 0.3 m FTXCN3203 FTXDP3203 –L = 0.6 m FTXCN3206 FTXDP3206 FTXIB1206 (2)L = 1 m FTXCN3210 FTXDP3210 FTXIB1210 (2)L = 2 m FTXCN3220 FTXDP3220 FTXIB1220 (2)L = 3 m FTXCN3230 FTXDP3230 –L = 5 m TXCN3250 FTXDP3250 FTXIB1250 (2)(2) Reference includes the Bus connection cable + the power supply cable.4Power supply connection cables5678Type of bus CANopen DeviceNet ProfiBusmachine bus fieldbus fieldbusType of female connectorType 7/8, 5-pin, at either endReferences Cable L = 0.6 m FTXDP2206L = 1 m FTXDP2210L = 2 m FTXDP2220L = 5 m FTXDP2250Type of female connectorType 7/8, 5-pin, at one end (other end free)Cable L = 1.5 m FTXDP2115References L = 3 m FTXDP2130L = 5 m FTXDP21509Accessories10Type of bus CANopen DeviceNet ProfiBus INTERBUSmachine bus fieldbus fieldbus fieldbusReferences Configuration CD-ROM FTXES00Diagnostics M12 adaptorFTXDG12Power supply T-connector FTXCNCT1 –Line terminator FTXCNTL12 FTXDPTL12 –7/18Other versions: please consult our Customer Care Centre.


ModiconAccessories for sensors/actuatorsM12 / M12 jumper cables1TypeMale / Female jumper cablesType of male connector, interface side M12, 4-pin, straight, screw thread M12, 4-pin, straight, screw thread M12, 5-pin, straight, screw threadType of female connector, sensor side M12, 3-pin, straight, screw thread M12, 4-pin, straight, screw thread M12, 5-pin, straight, screw threadCable PUR, black PUR, black PUR, blackReferences Cable L = 1 m XZCR1511040A1 XZCR1511041C1 XZCR1511064D1L = 2 m XZCR1511040A2 XZCR1511041C2 XZCR1511064D2M8/M8, M8/M12 and M12/DIN jumper cables23M8/M8, M8/M12 and M12/DIN jumper cables45TypeMale / Female jumper cablesType of male connector, interface side M8, 3-pin M12, 3-pin M12, 3-pin M12, 3-pinstraight, screw thread straight, screw thread straight, screw thread straight, screw threadType of female connector, sensor side M8, 3-pin M8, 3-pin M8, 3-pin DIN 43650Astraight, screw thread straight, clip together straight, screw thread elbowed, screw threadCable PUR, black PUR, black PUR, black PUR, blackReferences Cable L = 1 m XZCR2705037R1 XZCR1501040G1 XZCR1509040H1 XZCR1523062K1L = 2 m XZCR2705037R2 XZCR1501040G2 XZCR1509040H2 XZCR1523062K267Pre-wired connectors and splitter box8Type Connectors Pre-wired connectors Splitter box “Y”9Type of male connector, interface side M12, 4-pin M8, 3-pin M12, 5-pin, straight, screw thread 1 x M12 1 x M12Type of female connector, sensor side – – – 2 x M12 2 x M8Cable – – PUR, black –References Straight connector, screw thread XZCC12MDM40B XZCC8MDM30V – FTXCY1212 FTXCY1208Elbowed connector, screw thread XZCC12MCM40B – – – –Cable L = 0.5 m – – XZCP1564L05 – –L = 2 m – – XZCP1564L2 – –10Other versions: please consult our Customer Care Centre.7/19


Modicon FactoryCastModicon FactoryCast PLC modules and the ModiconFactoryCast Gateway combine the benefits of openWeb technologies with the reliability of industrialcontrol.In the areas of distributed infrastructure, RTUinstallations, industry, machinery and energy, theModicon FactoryCast ranges offer an ideal solutionfor all your remote diagnostics and maintenance,monitoring, control and programming needs.Schneider Electric’s communicationsolutions for industrial networks monitoryour control system applications to giveyou precise control and maintenance datain real time.Remote intelligent modules or in-rackmodules for PLCs, standalone productsand devices - the Modicon FactoryCast,AS-Interface and Modicon Connexiumranges provide access to advancedfunctions, flexible tools and services foroptimising communication between allyour automation products.AS-InterfaceAS-Interface is a quick expandablecabling system which connectsall components in a controlsystem with just a single cable.Intelligent, it features built-incommunication management.Modicon ConnexiumDesigned for open industrial solutions, ModiconConnexium products are the Ethernet-ready networkhubs, switches, transceivers, gateways and cables whichprovide you with integrated Ethernet solutions to uniteeverything in your installation, from device level all theway to your corporate intranet. Modicon Connexiumboosts network performance and reliability.


Networks connectivityand Web serversThis document is a selection ofthe top selling products.1ConneXium cabling systemHub, Transceiver, IP 67 Switch ............................................................................................... 8/2Switches ....................................................................................................................... 8/3 to 8/6Gateways & Converters ......................................................................................................... 8/7ConneXview Software ............................................................................................................ 8/8Cables & Connectors ............................................................................................................. 8/923AS-Interface cabling systemServers and GatewaysModicon interfaces for generic products ..................................................8/10 and 8/11IP20 interfacesIP67 interfacesDedicated components .................................................................................... 8/12 and 8/13For controlFor dialogueInstallation system ................................................................................................ 8/14 to 8/16Master modules, power supply unitsCables, repeatersAccessoriesTools ....................................................................................................................................... 8/17Adjustment and addressing terminalsSafety solutionsSafety monitorsSafety interfacessee Chapter 9 “Machine safety”Data server software,OPC Factory Server ................................................................................................................. 8/18Embedded Web Servers,FactoryCast and FactoryCast HMI ......................................................................................... 8/19Web Gateways for Remote control,FactoryCast Gateway and FactoryCast HMI Gateway ........................................... 8/20 and 8/21456789108/1


ConneXiumEthernet TCP/IP, Transparent ReadyCabling system: ConneXium Hub, Transceiverand Switch1Hub23Interfaces Copper cable ports Number and type 4 x 10BASE-T portsShielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair 100 mPower supply Voltage 24 V (18…32) DC, safety extra low voltage (SELV)Degree of protection IP 30Dimensions W x H x D40 x 125 x 80 mmConformity to standardscUL 60950, UL 508 and CSA 142, UL 1604 and CSA 213 Class 1 Division 2, e, GLFM 3810, FM 3611 Class 1 Division 2 , C-TICKReference 499 NEH 104 1045678TransceiverInterfaces Copper cable ports Number and type 1 x 100BASE-TX portShielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair 100 mFiber optic ports Number and type 1 x 100BASE-FX portConnectorsSCMediumMultimode optical fiberLength of optical fiber50/125 μm fiber 3000 m (1)62.2/125 μm fiber 3000 m (1)Attenuation analysis50/125 μm fiber 8 dB:62.2/125 μm fiber 11 dB:Power supply Voltage 24 V (18…32) DC, safety extra low voltage (SELV)Degree of protection IP 20Dimensions W x H x D47 x 135 x 111 mmConformity to standardscUL 60950, UL 508 and CSA 142, UL 1604 and CSA 213 Class 1 Division 2, e, GL , C-TICKReference 499 NTR 101 00(1) Length dependent on the attenuation analysis and attenuation of the optical fiber (typical value: 2000 m).910IP 67 switchTwisted pair, unmanagedInterfaces Copper cable ports Number and type 5 x 10BASE-T/100BASE-TX portsShielded connectors M12 (type D)MediumShielded twisted pair, category CAT 5ETotal length of pair 100 m with rated cablePower supply Voltage 24 VDC (18…32 VDC), safety extra low voltage (SELV)Degree of protection IP 65/67Dimensions W x H x D60 x 126 x 31 mmConformity to standardscUL 508 and CSA 22.2 14 , C-TICKReferenceTCS ESU 051 F08/2Other versions: please consult our Customer Care Centre.


ConneXiumEthernet TCP/IP, Transparent ReadyCabling system: ConneXium unmanaged switches1SwitchesCopper twisted pair, unmanagedInterfaces Copper cable ports Number and type 3 x 10BASE-T/ 100BASE-TXports4 x 10BASE-T/ 100BASE-TXports5 x 10BASE-T/ 100BASE-TXports8 x 10BASE-T/ 100BASE-TXportsShielded connectors Type RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair100 mFiber optic ports Number and type – 1 x 100BASE-FX ports – –Connectors – Duplex SC – –Medium – Multimode optical fiber – –Length of optical fiber50/125 μm fiber – 5000 m (1) – –62,2/125 μm fiber – 4000 m (1) – –Attenuation analys50/125 μm fiber – 8 dB – –62,2/125 μm fiber – 11 dB – –Power supply Voltage, safety extra low voltage (SELV) c 24 VDC (c 9,6…32 VDC)Power consumption Max. 2,2 W Max. 3,9 W Max. 2,2 W Max. 4,1 WConnector3 way removable connectorDegree of protection IP 30Dimensionss W x H x D 25 x 114 x 79 mm 35 x 138 x 121 mmWeight 0,113 kg 0,120 kg 0,113 kg 0,246 kgConformity to standards UL 508 and CSA 22.2 N° 142IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11AAlarm relay –Reference TCS ESU 033FN0 TCS ESU 043F1N0 TCS ESU 053FN0 TCS ESU 083FN0(1) Length dependent on the attenuation analysis and attenuation of the fi ber optic (typical value: 2,000 m).234567SwitchesCopper twisted pair and fibre optic, unmanagedInterfaces Copper cable ports Number and type 4 x 10BASE-T/100BASE-TX ports3 x 10BASE-T/100BASE-TX ports4 x 10BASE-T/100BASE-TX ports3 x 10BASE-T/100BASE-TX ports8 x 10BASE-T/100BASE-TX portsShielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair100 mFiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports –Connectors SC –Medium Multimode optical fiber Single mode optical fiber –Length of optical fiber50/125 μm fiber 5000 m (1) – –62.2/125 μm fiber 4000 m (1) – –9/125 μm fiber – 32 500 m (2) –Power supply Voltage 24 VDC (18…32), safety extra low voltage (SELV)Degree of protection IP 20Dimensions W x H x D 47 x 135 x 111 mmConformity to standardscUL 60950, cUL 508 and CSA 142, UL 1604 and CSA 213 Class 1 Division 2, e, GL , C-TICKReferences 499 NMS 251 01 499 NMS 251 02 499 NSS 251 01 499 NSS 251 02 499 NES 181 00(1) Length dependent on the attenuation analysis and attenuation of the fiber optic (typical value: 2,000 m).(2) Length dependent on the attenuation analysis and attenuation of the fiber optic (typical value: 15,000 m).8910Other versions: please consult our Customer Care Centre.8/3


ConneXiumEthernet TCP/IP, Transparent ReadyCabling system: ConneXium managed switches1SwitchesCopper twisted pair and fiber optic, managed2345Interfaces Copper cable ports Number and type 3 x 10/100BASE-TX ports 2 x 10/100BASE-TX ports 3 x 10/100BASE-TX ports 2 x 10/100BASE-TX portsShielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair 100 mFiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX portsConnectors Duplex SCMedium Multimode optical fiber Single mode optical fiberLength of optical fiber50/125 μm fiber 5,000 m (1) –62.2/125 μm fiber 4,000 m (1) –9/125 μm fiber – 32,500 m (2)Power supply Voltage Operation 9.6...60 VDC/18…30 VAC, safety extra low voltage (SELV)Degree of protection IP 20Dimensions W x H x D47 x 131 x 111 mmConformity to standardsIEC 61131-2, IEC 61850-3, UL 508, UL 1604 Class 1 Division 2, CSA C22.2 14 (cUL),CSA C22.2 213 Class 1 Division 2 (cUL), e, GL , C-TICKReferences TCSESM043F1CU0 TCSESM043F2CU0 TCSESM043F1CS0 TCSESM043F2CS0(1) Length dependent on the attenuation analysis and attenuation of the fiber optic (typical value: 2,000 m).(2) Length dependent on the attenuation analysis and attenuation of the fiber optic (typical value: 15,000 m).6789SwitchesCopper twisted pair, managedInterfaces Copper cable ports Number and type 4 x 10/100BASE-TX ports 8 x 10/100BASE-TX portsShielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair 100 mPower supply Voltage Operation 9.6...60 VDC/18…30 VAC, safety extra low voltage (SELV)Degree of protection IP 20Dimensions W x H x D 47 x 131 x 111 mm 74 x 131 x 111 mmConformity to standardsIEC 61131-2, IEC 61850-3, UL 508, UL 1604 Class 1 Division 2, CSA C22.2 14 (cUL),CSA C22.2 213 Class 1 Division 2 (cUL), e, GL , C-TICKReferences TCSESM043F23F0 TCSESM083F23F0108/4Other versions: please consult our Customer Care Centre.


ConneXiumEthernet TCP/IP, Transparent ReadyCabling system: ConneXium managed switches1SwitchesCopper twisted pair and fiber optic, managedInterfaces Copper cable ports Number and type 7 x 10/100BASE-TXports6 x 10/100BASE-TXports7 x 10/100BASE-TXports6 x 10/100BASE-TportsShielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair 100 mFiber optic ports Number and type 1 x 100BASE-FX 2 x 100BASE-FX 1 x 100BASE-FX 2 x 100BASE-FXport port port portConnectors Duplex SCMedium Multimode optical fiber (MM) Single mode optical fiber (SM)23Length of optical fiber50/125 μm fiber 5,000 m (1) –62.2/125 μm fiber 4,000 m (1) –9/125 μm fiber – 32,500 m (2)Power supply Voltage Operation 9.6...60 VDC/18…30 VAC, safety extra low voltage (SELV)Degree of protection IP 20Dimensions W x H x D74 x 131 x 111 mmConformity to standardsIEC 61131-2, IEC 61850-3, UL 508, UL 1604 Class 1 Division 2, CSA C22.2 14 (cUL),CSA C22.2 213 Class 1 Division 2 (cUL), e, GL , C-TICKReferences TCSESM083F1CU0 TCSESM083F2CU0 TCSESM083F1CS0 TCSESM083F2CS0(1) Length dependent on the attenuation analysis and attenuation of the fiber optic (typical value: 2,000 m).(2) Length dependent on the attenuation analysis and attenuation of the fiber optic (typical value: 15,000 m).4567SwitchesCopper twisted Copper twisted pair and fiber optic, managedpair, managedInterfaces Copper cable ports Number and type 16 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 22 x 10/100BASE-TX ports 14 ports 10/100BASE-T<strong>XS</strong>hielded connectors RJ45Total length of pair 100 mFiber optic ports Number and type – 2 x 100BASE-FX portsConnector – Duplex SCMedium – Multimode optical fiber Optical fiberLength of optical fiber50/125 μm fiber – 5,000 m (1)–62.2/125 μm fiber – 4,000 m (1) 32 500 M (2)Power supply Voltage Operation 9.6...60 VDC/18…30 VAC, safety extra low voltage (SELV)Degree of protection IP 20Dimensions W x H x D111 x 131 x 111 mmConformity to standards cUL 60950, UL 508 and CSA 142, UL 1604 and CSA 213 Class 1 Division 2, e, GL , C-TICK 243F2CU0References TCSESM163F23F0 TCSESM163F2CU0 TCSESM243F2CU0 TCSESM16F2CS0(1) Length dependent on the attenuation analysis and attenuation of the fiber optic (typical value: 2,000 m).8910Other versions: please consult our Customer Care Centre.8/5


ConneXiumEthernet TCP/IP, Transparent ReadyCabling system: ConneXium managed switches1SwitchesCopper twisted pair and fibre optic, managed - extended features234567Interfaces Copper cable ports Number and type 8 x 10/100 BASE-TX ports 6 x 10/100 BASE-TX ports 6 x 10/100 BASE-TX portsShielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair 100 mFiber optic ports Number and type – 2 x 100BASE-FX ports 2 x 100BASE-FX portsConnectors – Duplex SC Duplex SCMedium – Multi mode optical fi bre Single mode optical fi breLength of optical fiber50/125 μm fiber – 5,000 m (1) –62.2/125 μm fiber – 4,000 m (1) –9/125 μm fiber – – 32,500 m (2)Attentuation analysis50/125 μm fibre – 8 dB –62.2/125 μm fiber – 11 dB –9/125 μm fiber – – 16 dBEthernet servicesFDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration via Webaccess, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port.Topology Number of switches Cascaded UnlimitedRedundant in a ring max. 50RedundancyRedundant power supplies, redundant single ring, ring couplingPower supply Voltage Operation 18 - 60 V safety extra low voltage (SELV)Power consumption 10 W 12 W 12 WDegree of protectionIP30Dimensions W x H x D120 x 137 x 115 mmConformity to standardsIEC/EN 61131-2, IEC 61850-3, UL 508, UL ISA-12.12.-01 Class 1 Div 2 Group A, B, C, D, CSA 22.2 No.142 (cUL), CSA 22.2 No. 213 Class 1 Division 2 (cUL), CE, GL, C-TickAlarm relayPower supply fault, Ethernet network fault or communication port fault(2 A max. volt-free contact at 30 VDC)References TCSESM083F23F1 TCSESM063F2CU1 TCSESM063F2CS1(1) Length dependent on the attenuation analysis and attenuation of the fi lber optic (typical value: 2,000 m).(2) Length dependent on the attenuation analysis and attenuation of the fi lber optic (typical value: 15,000 m).89108/6Other versions: please consult our Customer Care Centre.


1Switches Copper twisted pair and fiber optic, managed Copper twistedpair, managedInterfaces Copper cable ports Number and type 8 x 10/100 BASE-TX ports 8 x 10/100 BASE-TX ports 2 x100 BASE-TX ports (Gigabits)Shielded connectors RJ45MediumShielded twisted pair, category CAT 5ETotal length of pair 100 mFiber optic ports Number and type 2 x 100BASE-SX ports (1) 2 x 100BASE-LH ports (2) 2 x 100BASE-LX ports (3) –Connectors LC –Medium Multimode optical fiber Single optical fibre Single mode and multimodeoptical fiber–Length of optical fiber–50/125 μm fiber 550 m – 550 m62.2/125 μm fiber 275 m – 550 m –9/125 μm fiber – 8 - 72,000 m 20,000 m –Attentuation analysis50/125 μm fibre 7,5 dB – 11 dB –62.2/125 μm fiber 7,5 dB – 11 dB –9/125 μm fiber – 6 - 22 dB 11 dB –Ethernet servicesFDR, SMTP V3, SNTP client, multicast fi ltering for optimization of the Global Data protocol, configurationvia Web ccess, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data streamcontrol, secure port.Topology Number of switches Cascaded UnlimitedRedundant in a ring max. 50RedundancyRedundant power supplies, redundant single ring, ring couplingPower supply Voltage Operation 9,6...60 VDC/18...30 VAC, safety extra low voltage (SELV)Degree of protectionIP20Dimensions W x H x D111 x 113 x 111 mmConformity to standardscUL 60950, UL 508 and CSA 22.2, UL 1604 and CSA 213 CSA 22.2 No. 213 Class 1 Division 2, C€, GLReferences TCSESM103F2LG0 TCSESM103F23G0(1) With TCSEAAF1LFU00 fiber optic module to be ordered separately(2) With TCSEAAF1LFH00 fiber optic module to be ordered separately(3) With TCSEAAF1LFS00 fiber optic module to be ordered separatelySwitches Copper twisted pair and fiber optic, managed Copper twisted pair,managedInterfaces Copper cable ports Number and type 6 x 10/100 BASE-TX ports 8 x 10/100 BASE-TX portsShielded connectors RJ45Total length of pair 100 mFiber optic ports Number and type 2 x 100 BASE-SX ports 3 x 100 BASE-LX ports -Connector Duplex SC -Medium Multimode optical fiber -Length of optical fiber50/125 μm fiber 5,000 m (1) -62.2/125 μm fiber 4,000 m (1) -9/125 μm fiber - - -Attenuation analysis50/125 μm fiber 8 dB -60.2/125 μm fiber 11 dB -9/125 μm fiber - -Ethernet servicesFDR, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration viaWeb access,IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control,secure port.Topology Number of switches Cascaded UnlimitedRedundant in a ring Max. 50RedundancyRedundant power suppliesReferences TCSESB083F23F0 TCSESB083F2CU0 TCSESB093F2CU02345678910Other versions: please consult our Customer Care Centre.8/7


ConneXiumEthernet gatewaysEthernet/Modbus gateway andEthernet/Modbus Plus gateway/router1Type of gateway TSX ETG 1002345Transparent ReadyservicesClassStandard WebservicesConfigurationRead/WriteDiagnosticB10Predefined Web pagesAcces to connected products list, reading of Modbus devices registersVia predefined Web pages : diagnostic on Ethernet and Modbus linksEthernet TCP/IP Modbus messaging Read/Write Modbus registers of connected devicescommunicationmanagementSNMPSNMP Agent, device administration with a SNMP managerservicesBOOTP protocol FDR Client (replacement of defective product)SecurityMiniature firewall on-board (IP address filtering) and password protectionEthernet connectivity Physical interface 10BASE-T/100BASE-TX (RJ45)Data rate10/100 Mbps with automatic recognitionMediumTwisted pairModbus connectivity Type of port RS 485 (2 or 4-wire) or RS 232ProtocolModbus (RTU and ASCII)Maxi transmission speed 38,4 Kbps (RS 485), 57,6 Kbps (RS 232)Number of devices32 max.Power supply24 VDC, 4 W or by power supply device PoE (Power Over Ethernet - IEEE 802.3af)Degree of protection IP 30Dimensions W x H x D72 x 81 x 76 mm, mounting on symmetrical DIN railConformity to standardsUL, cUL (conforming to CSA C22-2 no. 14-M91), UL508 , C-TICK, eReference TSX ETG 100 (1)(1) Fonctions: Twido, Compact, Momentum, TSX Micro, Altivar, Altistart, Magelis, ... All products compatible with Modbus standard.678910Type of gatewayEthernet/Modbus Plus gateway/router Class B10Transparent Ready ClassB10servicesStandard Web Configuration Predefined Web pagesservicesRead/WriteAcces to connected products list, reading of Modbus Plus devices registersDiagnosticVia predefined Web pages : diagnostic on Ethernet and Modbus Plus linksStandard Ethernet TCP/IP communication Modbus TCP messagingservicesSNMP AgentFunctions Communication gateway Ethernet/Modbus Plus(many-to-many Modbus Plus)Interface for programmingEthernet/Modbus PlusInterfaces Ethernet TCP/IP port Type 1 x 10BASE-T/100BASE-T<strong>XS</strong>hielded connectors RJ45MediumShielded twisted pairMax. distances 100 m (327 ft)Serial port Type 1 x Modbus PlusShielded connectors 9-way SUB-D connectorMediumShielded twisted pair (single or double)Power supply Voltage 110/220 VAC (93.5 VAC…242 VAC), 47…63 HzDegree of protection IP 20Dimensions W x H x D122 x 229 x 248 mmConformity to standardsUL 508, CSA 142, eReference 174 CEV 200 40 (2)(2) Fonctions: 1 Ethernet port, 10BASE-T/100BASE-TX, 1 Modbus Plus port8/8Other versions: please consult our Customer Care Centre.


ConneXiumThese cables conform to:- EIA/TIA-568 standard, category CAT 5E,- IEC 11801/EN 50173 standard, class D.Their fire resistance conforms to:- NFC 32070# C2 classification- IEC 322/1 standards- Low Smoke Zero Halogen (LSZH).EIA/TIA 568 shielded twisted pair cables for CE marketEthernet TCP/IP, Transparent ReadyCabling system: Connection componentsShielded copper connection cablesConneXium shielded connection cables are available in two versions to meet the various current standardsand approvals:EIA/TIA 568 shielded twisted pair cables1Length m / (ft) 2 (6.6) 5 (16.4) 12 (39.4) 40 (131.2) 80 (262.5)Straight cables Preformed at both ends 2 RJ45 connectors for connection to terminal devices (DTE)References 490 NTW 000 02 490 NTW 000 05 490 NTW 000 12 490 NTW 000 40 490 NTW 000 80Crossed cord cables Preformed at both ends 2 RJ45 connectors for connections between hubs, switches and transceiversReferences Reerences – 490 NTC 000 05 – 490 NTC 000 40 490 NTC 000 80EIA/TIA 568 shielded twisted pair cables23Cable material is :- CEC type FT-1- NEC type CMEIA/TIA shielded twisted pair cables for UL markets4Length m / (ft) 2 (6.6) 5 (16.4) 12 (39.4) 15 (49.2) 40 (131.2) 80 (262.5)Straight cables Preformed at both ends 2 RJ45 connectors for connection to terminal devices (DTE)References 490 NTW 000 02U 490 NTW 000 05U 490 NTW 000 12U – 490 NTW 000 40U 490 NTW 000 80UCrossed cord cables Preformed at both ends 2 RJ45 connectors for connections between hubs, switches and transceiversReferences – 490 NTC 000 05U – 490 NTC 000 12U 490 NTC 000 40U 490 NTC 000 80U5Cables M126Cables M127M12 / M12 Length (m) 1 3 10 25 40ReferenceTCSECL1M1MppS2ppRJ45 / M12 Length(m) 1 3 10 25 40ReferenceTCSECL1M3MppS2pp8These glass fiber optics are for making connections:- To a terminal device (DTE)- Between hubs, transceivers and switchesGlass fiber optic cablesGlass fiber optic cablesLength m / (ft) 5 (16.4) 5 (16.4) 3 (9.8) 5 (16.4)Glass fiber optic cables Preformed at both ends 1 SC connector 1 ST connector (BFOC) 2 MT-RJ connectors1 MT-RJ connector 1 MT-RJ connectorReferences 490 NOC 000 05 490 NOT 000 05 490 NOR 000 03 490 NOR 000 05910Other versions: please consult our Customer Care Centre.8/9


ConneXiumWiFi ProductsWiFi Access Points and Clients - WiFi Antennas12345Access Points and ClientsDual band industrial wireless LANAccess Point/Client based on IEEE802.11a/b/g/h/iDual band industrial high performancewireless LAN Access Point/Client basedon IEEE 802.11a/b/g/h/nWireless standard IEEE 802.11a/b/g/h/i IEEE 802.11a/b/g/h/i IEEE 802.11a/b/g/h/n IEEE 802.11a/b/g/h/nOperating frequencies 2.4GHz & 5GHz 2.4GHz & 5GHz 2.4GHz & 5GHz 2.4GHz & 5GHzIP Rating IP 40 IP 67 IP 40 IP 67Mounting Din Rail Wall / Mast Din Rail Wall / MastRadios Access Point: 2Client: 12 1 1Nominal Data rate 54 Mbps 54 Mbps 300 Mbps 300 MbpsAntenna connections 4 x RP-SMA 4 x N-type 3 x RP-SMA 4 x N-typeEthernet connections (10/100BASE-TX) Access Points: 2Client: 11 2 2Wireless connections2 x WLAN Interfaces8 SSIDs per interface2 x WLAN Interfaces8 SSIDs per interface1 x WLAN Interfaces8 SSIDs per interface1 x WLAN Interfaces8 SSIDs per interfaceReferences Global TCSGWA242 TCSGWA272 TCSNWA241 TCSNWA271North America (FCC approved) TCSGWA242F – TCSNWA241F TCSNWA271FClient only TCSGWC241 – – –ATEX Compliant – – – TCSNWA2A1Antennas TSCG**** Compatible References (1) TSCN**** Compatible References (1)6782.4 GHz 2.4 GHz Omni Directional (6dBi) TCSWAB2O –2.4 GHz Directional (14dBi) TCSWAB2D –2.4 GHz Dual Slant (8dBi) TCSWAB2S TCSWAB2SLeaky Cable – 50 meter TCSWABC5 –Leaky Cable – 100 meter TCSWABC10 –5 GHz 5 GHz Omni Directional (5dBi) TCSWAB5O –5 GHz Directional – Medium (18.5dBi) TCSWAB5D –5 GHz Directional – Long (23dBi) TCSWAB5V TCSWAB5V5 GHz Directional – 802.11n (23dBi) TCSWAB5VN TCSWAB5VN5 GHz Dual Slant (9dBi) TCSWAB5S –5 GHz Directional – 802.11n (9dBi) – TCSWAB5DNDual Band Dual Band Hemispherical (6dBi/8dBi) TCSWABDH –Dual Band Omni (3.5dBi/5.5dBi) – TCSWABDON(1) Consult www.schneider-electric.com for a complete list of antenna cables and accessories for WiFi products9108/10Other versions: please consult our Customer Care Centre.


ConneXiumNotes12345678910Other versions: please consult our Customer Care Centre.8/11


AS-InterfaceModicon interfaces for generic productsIP20 for mounting in enclosure1234Modular interface, width 25 mm Analogue DigitalV2.1 with standard addressingNumber of inputs 2 (0…10V) 2 (0/4…20mA) 4 4 4 isolatedNumber of outputs – – 4 relay, 2A 4 solid state, 0.5A 4 solid state, 0.5AType of addressingStandardSupply by AS-Interface Inputs and sensor supply (200 mA max.) –Supply by 24 VDC external source (black AUX cable) – – – Outputs (2)AS-Interface profile S.7.3.F.D S.7.3.F.D S.7.0.F.E S.7.0.F.E S.7.0.F.EMaximum consumption from AS-Interface (excluding sensor supply) 60 mA 60 mA 110 mA 50 mA 20 mADimensions (WxDxH) 25x77x87 mm 25x77x87 mm 25x77x87 mm 25x77x87 mm 25x77x87 mmReferences ASI20MA2VU ASI20MA2VI ASI20MT4I4OR ASI20MT4I4OS ASI20MT4I4OSAAccessory (1) for connection to flat cables TCSATN01N2 TCSATN01N2 TCSATN01N2 TCSATV01N2 TCSATV01N2(1) Or direct screw terminal connection (without accessory).(2) Inputs, outputs and sensor supply (200 mA max.).567Modular interface, width 25 mmDigitalV2.1 with Extended (A/B) addressingNumber of inputs 4 2 4 4 4 isolatedNumber of outputs – 1 triac, 2A 3 relay, 2A 3 solid state, 0.5A 3 solid state, 0.5AType of addressingExtended (A/B)Supply by AS-Interface Inputs and sensor supply (200 mA max.) (3) –Supply by 24 VDC external source (black AUX cable) – – – Outputs (2)AS-Interface profile S.0.A.7.0 S.3.A.7.0 S.7.A.7.0 S.7.A.7.0 S.7.A.7.0Maximum consumption from AS-Interface (excluding sensor supply) 50 mA 40 mA 90 mA 50 mA 20 mADimensions (WxDxH) 25x77x87 mm 25x77x87 mm 25x77x87 mm 25x77x87 mm 25x77x87 mmReferences ASI20MT4IE ASI20MT2I1OTE ASI20MT4I3ORE ASI20MT4I3OSE ASI20MT4I3OSAEAccessory (1) for connection to flat cables TCSATN01N2 TCSATN01N2 TCSATN01N2 TCSATV01N2 TCSATV01N2(1) Or direct screw terminal connection (without accessory).(2) Inputs, outputs and sensor supply (200 mA max.).(3) Except ASI20MT4I3ORE (170 mA max.).89108/12Other versions: please consult our Customer Care Centre.


IP67 for mounting on machine1InterfaceDigitalV2.1 with extended (A/B) addressingNumber of inputs 4 2 – 4 4 4 8Input cabling Standard (1 x M12) "Y" (2 x M12) "Y" (4 x M12)Number of outputs – 2 solid-state, 2A 3 solid-state, 2A 3 solid-state, 2A – 3 solid-state, 2A –Type of addressingExtended (A/B)Supply by AS-InterfaceInputs and sensor supply (200 mA max. except ASI67FFP22•: 100 mA)Supply by 24 VDC external source (black AUX cable) – Outputs – Outputs – Outputs –AS-Interface profile S.0.A.7.0 S.B.A.7.0 S.8.A.7.0 S.7.A.7.0 S.0.A.7.2 S.7.A.7.E S.0.A.7.2 (2x)Maximum consumption from AS-Interface (excluding sensor supply) 45 mA 32 mA 18 mA 48 mA 45 mA 48 mA 90 mADimensions (WxDxH) 45X42X80mm 45X42X80mm 45X42X80mm 60x30,5X151mm 45X42X80mm 60x30,5X151mm 60x30,5X151mmConnection IDC Interface ASI67FFP40E ASI67FFP22E ASI67FFP03E ASI67FFP43E ASI67FFP40EY ASI67FFP43EY ASI67FFP80EYStandard connection base ASI67FFB01 (1) ASI67FFB01 (1) ASI67FFB01 (1) ASI67FFB03 ASI67FFB01 (1) ASI67FFB03 ASI67FFB03M12 connector Interface + Connection base ASI67FMP40E ASI67FMP22E ASI67FMP03E ASI67FMP43E ASI67FMP40EY ASI67FMP43EY –(1) A connection base with fixing centres that are compatible with the ASIB4VM12 connection base is available. Reference ASI67FFB02.234InterfaceDigitalV2.1 with standard addressingNumber of inputs 4 2 – 4 4 8Input cabling Standard (1 x M12) "Y" (2 x M12) "Y" (4 x M12)Number of outputs – 2 solid-state, 2A 4 solid-state, 2A 4 solid-state, 2A 4 solid-state, 2A –Type of addressingStandardSupply by AS-InterfaceInputs and sensor supply (200 mA max. except ASI67FFP22•: 100 mA)Supply by 24 VDC external source (black AUX cable) – Outputs Outputs Outputs Outputs –AS-Interface profile S.0.0.F.E S.3.0.F.E S.8.0.F.E S.7.0.F.E S.7.1.F.E S.0.1.F.F (2x)Maximum consumption from AS-Interface (excluding sensor supply) 45 mA 32 mA 19 mA 49 mA 49 mA 90 mADimensions (WxDxH) 45X42X80mm 45X42X80mm 45X42X80mm 60x30,5X151mm 60x30,5X151mm 60x30,5X151mmConnection IDC Interface ASI67FFP40D ASI67FFP22D ASI67FFP04D ASI67FFP44D ASI67FFP44DY ASI67FFP80DYStandard connection base ASI67FFB01 (1) ASI67FFB01 (1) ASI67FFB01 (1) ASI67FFB03 ASI67FFB03 ASI67FFB03M12 connector Interface + Connection base ASI67FMP40D ASI67FMP22D ASI67FMP04D ASI67FMP44D ASI67FMP44DY –(1) A connection base with fixing centres that are compatible with the ASIB4VM12 connection base is available. Reference ASI67FFB02.5678InterfaceDigitalV2.1 (V1 compatible) with standard addressingNumber of inputs 4 2 – 4Input cablingStandard (1 x M12 input)Number of outputs – 2 solid-state, 2A 4 solid-state, 2A 4 solid-state, 2AType of addressingStandardSupply by AS-InterfaceInputs and sensor supply (200 mA max. except ASI67FFP22•: 100 mA)Supply by 24 VDC external source (black AUX cable) – Outputs Outputs OutputsAS-Interface profile S.0.0.F.F S.3.0.F.F S.8.0.F.F S.7.0.F.FMaximum consumption from AS-Interface (excluding sensor supply) 45 mA 32 mA 19 mA 49 mADimensions (WxDxH) 45x42x80 mm 45x42x80 mm 45x42x80 mm 60x30.5x151 mmConnection IDC Interface ASI67FFP40A ASI67FFP22A ASI67FFP04A ASI67FFP44AStandard connection base ASI67FFB01 ASI67FFB01 ASI67FFB01 ASI67FFB03910Other versions: please consult our Customer Care Centre.8/13


AS-InterfaceDedicated componentsFor control12345Starter in insulated enclosure (1)Control byV1 Black rotary knob (blue bkgrnd.) PushbuttonsType of addressingStandardSupply by AS-Interface Inputs, sensor supply (2)Supply by 24 VDC external source (black AUX cable) (2)AS-Interface profileS.7.F.F. (LF3....) / S.7.A.7.0. (LF4....)Maximum consumption from AS-Interface20 mADimensions (WxDxH)175x175x195 mmReferences (3) Non reversing LF3PppD LF3MppD(see table below) Reversing LF4PppD LF4MppDConnection to AS-Interface and external supply (AUX) by accessory for fl at cable: TCSATN011F1 (AS-Interface and AUX cables) or TCSATV011F1 (AS-Interface cable).(1) For an LF3 or LF4 starter in a metal enclosure, add the letter M after the 3 rd digit in the references listed above (example: LF3P02D becomes LF3MP02D).(2) Contactors supplied by AS-Interface or external source, confi gurable directly on terminal block.(3) To complete the reference, replace pp by the numbers indicated in the table below. (Example: LF3PppD becomes LF3P00D).kW A pp kW A pp– without MCB 00 0.75 1.6…2.5 070.06 0.16…0.25 02 1.1 / 1.5 2.5…4 080.09 0.25…0.40 03 2.2 4…6.3 100.12 / 0.18 0.40…0.63 04 3 / 4 6…10 140.25 0.63…1 05 5.5 9…14 160.37/ 0.55 1…1.6 06kW= Motor power ratings in category AC-3, 400/415V, in kilowatts.A= Adjustable range of circuit-breaker thermal trips, in amperes.678910Communication interface forTeSys UV2.1Type of addressing Standard Extended (A/B)Supply by AS-Interface – –Supply by external source (AUX) Coil CoilAS-Interface profile S.7.D.F.0 7.A.7.EMaximum consumption from AS-Interface 30 mA 30 mADimensions (WxDxH) depending on LU model depending on LU modelReferences ASILUFC5 ASILUFC51Recommended accessory for connection to AS-Interface cable (4) TCSATV01N2 TCSATV01N2(4) Or direct screw terminal connection to AS-Interface and external supply (AUX).8/14Other versions: please consult our Customer Care Centre.


For dialogue1Control stationsControl stations with 2 pushbuttonsV2.1 Black and white Green and red Green and red illuminatedType of addressing Extended (A/B) Extended (A/B) Extended (A/B)Supply by AS-Interface Buttons Buttons Buttons and pilot lightsSupply by external source (AUX) – – –AS-Interface profile S.B.A.E. S.B.A.E. S.B.A.E.Consumption from AS-Interface < 45 mA < 45 mA < 80 mADimensions (WxDxH) 68x62x118 mm 68x62x118 mm 68x65x118 mmReferences XALS2001H XALS2002H XALS2003HRecommended accessory for connection to AS-Interface cable (5) TCSATN011F1 TCSATN011F1 TCSATN011F1(5) Or direct screw terminal connection to AS-Interface and external supply (AUX).234Interface (6)For 2 control units and 2 pilot lightsV2.1Number of pages available –Number of inputs 2Number of outputs2 solid state, 0.5 AType of addressingStandardSupply by AS-InterfaceInputs and pilot lightsAS-Interface profileS.B.A.E.Maximum consumption from AS-Interface80 mA– Dimensions (WxDxH)52x15x38 mmReferencesXALSZ1E(6) Direct screw terminal connection to AS-Interface or by accessory for flat cable: TCSATN01N2.5678Indicator banks, Ø 70 mm (9) Base units and cover Illuminated units AudibleV2.1 “Flash” discharge tube Steady light unitType of addressing Standard Standard – – –Connection to AS-Interface cable and AUX (male M12 connector) yes yes, remote L=1m – – –Supply by AS-Interface (7) (7) – – –Supply by external source (AUX) (7) (7) – – –AS-Interface profile S.7.F S.7.F – – –Consumption from AS-Interface, supply by AS-Interface / external 250 / 30 mA 250 / 30 mA – – –Light source – – 5 Joule LED –Buzzer – – – – 70…80 dB at 1mReferences XVBC21A XVBC21B XVBC6Bp (8) XVBC2Bp (8) XVBC9BRecommended accessory for connection to AS-Interface cable & AUX TCSATN011F1 TCSATN011F – –(7) Illuminated units supplied by AS-Interface or externally, configurable by shunt.(8) To complete the reference, replace the p by the following number designating the colour: green: 3, red: 4, orange: 5, blue: 6, clear: 7, yellow: 8.(9) To obtain a complete indicator bank, order a base unit + the illuminated or audible units (5 units maximum).910Other versions: please consult our Customer Care Centre.8/15


AS-InterfaceInstallation systemMaster modules1Platform Twido Premium Micro Quantum Ethernet GW2345678Maximum number of master modules per PLC 2 2, 4 or 8 depending 1 8 (1) –on processorCompatibility with AS-Interface interfaces and components V1 / V2.1 V1 / V2.1 V1 V1 V1 / V2.1 / V3.0Direct connection to AS-Interface cable by terminal block by terminal block by terminal block by terminal block by terminal blockMaximum number of addresses 62 62 31 31 62Type of addressing Standard / Standard / Standard Standard Standard /Extended (A/B) Extended (A/B) Extended (A/B)Compatibility with analogue interfaces Yes Yes – – YesCompatibility with safety interfaces Yes Yes Yes Yes YesAS-Interface profile M.3 M.2.E M.2 M.2 M.4References TWDNOI10M3 TS<strong>XS</strong>AY1000 TS<strong>XS</strong>AZ10 140EIA92100 TCSAGEA1SF13F(1) 4 per local rack, 4 per remote I/O, 2 per distributed I/O.Current in A at 24 V7655,844,53231012 3 4 5Current in A at 30 V AS-InterfacePower supply unitsType of supply AS-Interface AS-Interface + AuxiliaryInput voltage 100…240 VAC 100…240 VAC 100…240 VACAS-Interface output voltage 30 VDC 30 VDC 30 VDCAuxiliary output voltage – – 24 VDCAS-Interface nominal power 73 W 146 W 73 WAuxiliary nominal power – – 72 WAS-Interface nominal current 2.4 A 4.8 A 2.4 AAUX nominal current – – 3 ADirect connection to AS-Interface cable by terminal block by terminal block by terminal blockDimensions (WxDxH) 54x120x120 mm 81x120x120 mm 81x120x120 mmReferences without earth fault detection ASIABLB3002 ASIABLB3004 ASIABLM3024with earth fault detection ASIABLD3002 ASIABLD3004 –(2) Power supply unit with constant maximum output, see curve above.Insulation control relay9TypeFor AS-Interface line10Degree of protectionIP20Number of C/O contacts2 relays, each with 1 N/O contactRated operational voltage50 VDCDimensions (WxDxH)90x58x76 mmReferences RM0PAS101 (3)(3) Provided with an impedance adapter.8/16Other versions: please consult our Customer Care Centre.


Cables, repeater and line extension1TypeYellow AS-Interface Black Auxiliary Repeater (5) Line ExtensioncablecableWire c.s.a. 2 x 1.5 mm 2 2 x 1.5 mm 2 – –References Cable L = 20 m XZCB10201 (4) XZCB10202 (4) – –L = 50 m XZCB10501 (4) XZCB10502 (4) – –L = 100 m XZCB11001 (4) XZCB11002 (4) – –Reference of repeater – – ASIRPT01 TCSARR011M(4) Standard cable. For TPE cable (oil and vapour resistant) add the letter H to the end of the reference, example: XZCB10201 becomes XZCB10201H.(5) Enables an AS-Interface network to be extended by 100 m. Direct connection to the AS-Interface yellow cable by IDC23Tap-offs for flat cable(For connecting interfaces and components)45Connection to cable by IDC AS-Interface AS-Interface + AuxiliaryIP67IP67Connection to the AS-Interface component M12 connector (6) Bared wires (7) M12 connector (6) Bared wires (8)References Cable L = 1 m TCSATN011F1 – TCSATV011F1 –L = 2 m TCSATN011F2 TCSATN01N2 TCSATV011F2 TCSATV01N2(6) Female 5-pin M12 end connector, screw threaded for connection with M12 male connector.(7) 2 x 0.34 mm 2 for product with terminal block.(8) 4 x 0.34 mm 2 for product with terminal block.67T connectors89Connection to cable by IDC T connector BranchAS-Interface IP 67AS-Interface or Auxiliaires IP 67Connection to the AS-Interface sensor or actuator 1 x M12 connector 5-pin female, screw threaded Extension for 2 flat cablesReferences TCSATN011F TCSATN02V10Other versions: please consult our Customer Care Centre.8/17


AS-InterfaceInstallation systemJumper cables M12 / M121TypeMale / Female jumper cable2Male connector type, interface side M12, 3-pin, straight, screw thread. M12, 4-pin, straight, screw thread. M12, 5-pin, straight, screw thread.Female connector type, sensor side M12, 3-pin, straight, screw thread. M12, 4-pin, straight, screw thread. M12, 5-pin, straight, screw thread.Cable PUR, black PUR, black PUR, blackReferences Cable L = 1 m XZCR1511040A1 XZCR1511041C1 XZCR1511064D1L = 2 m XZCR1511040A2 XZCR1511041C2 XZCR1511064D234Jumper cables M12 / M8 or DIN5TypeMale / Female jumper cable67Male connector type, interface side M12, 3-pin, straight, screw thread. M12, 3-pin, straight, screw thread. M12, 3-pin, straight, screw thread.Female connector type, sensor side M8, 3-pin, straight (1) M8, 3-pin, straight, screw thread. DIN 43650A, elbowed, screw thrd.Cable PUR, black PUR, black PUR, blackReferences Cable L = 1 m XZCR1501040G1 XZCR1509040H1 XZCR1523062K1L = 2 m XZCR1501040G2 XZCR1509040H2 XZCR1523062K2(1) Clip together connector.8Connectors, splitter box9Type Connectors Pre-wired connectors Splitter box10Male connector type, interface side M12, 4-pin M12, 5-pin, straight, screw thread. 1 x M12, 5-pin, straight, screw thrd.Female connector type, sensor side – – 2 x M12, 5-pin, straight, screw thrd.Cable – PUR, black –References Straight connector, screw thread. XZCC12MDM40B – FTXCY1212Elbowed connector, screw thread. XZCC12MCM40B – –Cable L = 0.5 m – XZCP1564L05 –Cable L = 2 m – XZCP1564L2 –8/18Other versions: please consult our Customer Care Centre.


ToolsAdjustment and addressing terminals1DisplayDegree of protectionAS-Interface voltage / current measurementAddresses stored in memoryAccess to functionsCompatibilityOperating timeReferencesReference with set of 7 leads + protective cover for terminal25 mm LCD screenIP40yesyesdirect by selector switchV1/V22500 addressing operationsASITERV2ASITERV2SET23Addressing accessories for terminals ASITERV2and XZMC1145Product connection Infrared addressing SocketFor products ASISSL… ABE8… / APP1 / ASILUF… /XBZS43 / ASI20MReferences ASITERIR1 XZMG12678Product connection M12, male M12, female Jack plugFor products (2) ASI67FMPASI20M… / ASI67FFP…XVB… / XAL… / LF…References ASITERACC1M ASITERACC1F ASITERACC(2) Possibility to connect AS-Interface cable using T connector TCSATN011F.910Other versions: please consult our Customer Care Centre.8/19


OFSOPC data server software12TypeOPC data serverOFS SmallOFS LargeItems number 1000 items UnlimitedOPC protocols OPC DA OPC DA, OPC XML DA,References Single station li cence TLX CD SU OFS 33 TLX CD LU OFS10 stations licence TLX CD ST OFS 33 TLX CD LT OFS 33200 stations licence – TLX CD LF OFS 3334Remote clientapplicationprogramDCOM ouHTTPOFS stationLocal clientapplicationprogramEthernet TCP/IP networkData symbol(Concept, PL 7 or Unity proModbus networkX-Way network5678910MomentumPremiumTSX MicroQuantumDescription:Based on the OPC protocols, Schneider-Electric’s OFS software (OPC Factory Server) enables local orremote OPC client applications such as SCADA, supervisors or custom interfaces, to access Schneiderdevices and PLCs data in real time.OFS software is a multi-device data server which provides simultaneous use of various communicationprotocols, and allows client applications to access control data via physical addresses or via symbolsSupported devices :p Modicon Quantum, Premium, Micro, Compact and Momentum PLCsp TSX Series 7 and April Series 1000 Schneider-Electric PLCsp Serial Modbus or Uni-Telway devices connected via Schneider-Electric and Merlin Gerin gatewaysTSX ETG 10xx, EGX xxx ranges etc.Supported networks and protocols :p Modbus: Serial Modbus, Modbus Plus, Modbus TCP/IP.p XWAY/UNI-TE: Uni-Telway, FIPWAY, ETHWAY, ISAWAY, PCIWAY.Openess:OFS V3.3, integrates the most recent specifications of the OPC Foundation:p OPC-DA (OPC Data Access)p .NET API interfacep OPC XML-DA V1.0 (OPC XML Data Access)The development of specialized interfaces is even more easy and open.Developers and System integrators can develop custom applications (in Visual Basic, VBA for Excel,C++, etc) requiring access to Schneider Electric control devices. The OPC XML-DA V1.0 interface isdesigned to provide an interface for Windows and non-Windows client applications and remote access viathe Internet through firewalls.8/20Other versions: please consult our Customer Care Centre.


FactoryCastWeb servers and Gateways1FactoryCast modules for PLC“ Ready to use” diagnostic and monitoring functions embedded in a PLC module accessibleremotely via a simple Internet browser:b Real-time communication based on Ethernet TCP/IP (Modbus and Uni-TE)b Secure access to the PLC system and application diagnosticsb Numerical or graphical data monitoring and controlb E-mail notificationsb Web server open to user customization and creation of Web pages for diagnostics suitedto your needsb Library of animated graphic objectsb Open communications using SOAP/XML protocol as a server interface (Web services)23Embedded in the TCP/IP communication modules for Modicon M340,Premium and Quantum PLCs, FactoryCast Web servers provide securedaccess to the diagnotics, monitoring and maintenance functionsof your automation installations via a simple web browser.In the areas of distributed infrastructures, transport, RTU installations,industry and machines, ETG 1000 / 3000 modules more thansatisfy your requirements for remote diagnotics and maintenance,remote monitoring and control, and remote programming.FactoryCast HMI modules for PLCDiagnostic functions Identical as FactoryCast modules + Built-in HMI / SCADA functionsembedded in a PLC module:b Visualization of Unity Pro PLC program and Operator screens via Web pagesb PLC data acquisitionb Calculations scripts for data-processing Real-time database (1000 variables)b Alarm and report notifications via E-mailb Archiving of data directly into database servers (SQL, Oracle, MySQL)b Data logging in CSV files in the module.b Recipe management with read Databaseb Dynamic HTML Reporting functionb Web server open to user Web pages customizationb Built-in Supervision via graphic screens and custom Web pagesb Data monitoring and Graphic monitoring (read/write)b Library of animated graphic objectsb Open communication using SOAP/XML protocol as a server interface (Web services)FactoryCast Gateways - ETG 1000 / 10.. modulesCost-effective web gateways offer integrating in a stand-alone module:b All Communications network interfaces: Ethernet TCP/IP, Modbus and Uni-Telwayb Remote access functions, RAS server,b Transparent gateway / Router functionsb Notification of alarms via E-mailb Data monitoring and Graphic monitoring (read/write)b A user customizable Web server for creating an interface fully adapted to your needsb Library of animated graphic objectsFactoryCast HMI Gateways - ETG 3000 / 30.. modules“All in one” Web gateway module integrating in a stand-alone device:b a built-in modem (PSTN or GSM/GPRS) depending on the referenceb Secured access : VPN, data encryption and IP filtering.b A Remote Access server function (RAS)b 2 Ethernet ports and a Modbus serial portb Transparent gateway router functions NAT to Ethernet or Modbus serial devicesb I/O card : 6 discrete inputs/ 2 discrete outputsb Operating temperature : -25°C to +75°Cb User customizable Web serverb Built-in Supervision via graphic screens and custom Web pagesb Data monitoring and Graphic monitoring (read/write)b Data Acquisition, Data Processing and Data logging in the module (CSV files)b Archiving of data directly into database servers (SQL, Oracle, MySQL)b Alarms and reports via E-mail / SMSb Open communication using SOAP/XML protocol as a server interface45678910Other versions: please consult our Customer Care Centre.8/21


FactoryCastFactoryCast PLCEmbedded Web Servers12ApplicationsTarget devices Type TSX MicroPLCsNetwork & Remote access Remote accessservicesWeb Server modules for PLCsFactoryCastModicon M340PLCsIntranet or via external RAS/modemModiconPremium PLCsModiconQuantum PLCsFactoryCast HMIModiconPremium PLCsModiconQuantum PLCs3Remote programming, downloading via FTP, access to Web server via Internet browserGateway function –Serial protocols –Ethernet protocolsModbus TCP,Uni-TEModbus TCPModbus TCP,Uni-TEModbus TCPModbus TCP,Uni-TEModbus TCP456TCP/IP protocolsBootP/DHCP, DNS, SNMP agent, SMTP client, NTP client, FTPSecurityProtection by IP address filtering and passwordsWeb server Characteristics HTTP and FTP server, 8 Mb memory available for user, hosting of user Web pages and documents (Doc,Pdf, Excel)Predefined services Configuration Via Web Designer software or predefined Web pagesDiagnosticsSystem, rack and PLC I/O diagnostics via predefined Web pagesMonitoring of variablesMonitoring of devices and application via animated data (read/write variables)Alarm managementPLCs and applications alarms monitoring via predefined Web pagesCustomizable services Graphic views Graphic monitoring via animated pages (integrated graphic editor)Unity Pro operator screen – Display in the form of Web pagesUser Web pagesGraphic monitoring via animated Web pages created by the userAdvanced services and HMI Calculation scripts – Arithmetic and logical scriptsE-mail serviceAlarm notification by E-mailData logging – Data logging in the module withtime stamping (CSV files)Database connection – Direct logging in an SQL,Oracle, MySQL database serversReport service – Dynamic HTML report management7Recipe service – Management of “Recipe” data(storage and read locally or onremote database)PLC programme visualizationby Web page– All the languages supported byUnity Pro, are accessible by Webpage on Runtime, without Unity Pro8Application development sofwareWeb DesignerSupplied with each module9References TSXETZ510 BMXNOE0110 TSXETY5103 140NOE77111 TSXWMY100 140NWM10000108/22Other versions: please consult our Customer Care Centre.


FactoryCast GatewayWeb Gateways for Remote control1Standalone Gateway, Web Server for Remote AccessFactoryCast Gateway ETG 10p0All equipment supportingModbusAll equipment supportingUni-TelwayIntranet or via external Modem, integrated RAS functionFactoryCast HMI Gateway ETG30ppAll Modicon PLCs and third-party equipment supporting ModbusIntranet or ModemExternal modem, integrated RASIntranet or ModemIntegrated PSTN/RTC/GSM modem and RAS modem, NAT2Remote programming, downloading via FTP, access to Web server via Internet browserEthernet to Modbus serialModem to Modbus serial and EthernetEthernet to Uni-Telway serialModem to Uni-Telway and EthernetEthernet to Modbus serialModem to Modbus serial and Ethernet (Modbus, UNITE)Modbus (Master) Uni-Telway (Slave) Modbus (Master)Modbus TCPModbus TCP, Uni-TE (ModiconPremium, Modicon TSX Micro)Modbus TCPUni-TE TCPBootP/DHCP, SNMP agent, SMTP client, NTP client, FTPDHCP, DNS, SNMP agent, SMTP client, NTP client, FTPProtection by IP address fi ltering and passwordProtection by IP address filtering and password + Tunnels VPN & encryption of the datas.HTTP and FTP server, 8 Mb memory available for user, hosting ofuser Web pages and documents (Doc, Pdf, Excel)Via Web Designer software or predefined Web pagesDiagnostics of serial devices via predefined Web pagesHTTP and FTP server, 32 Mb memory available for user Web pages, memory extension using CompactFlash cards 1 Gb max., hosting of user Web pages and documents (Doc, Pdf, Excel)Network diagnostics, diagnostics of serial devices and Ethernet via predefined Web pagesMonitoring of devices and application via data tables (read/write variables)Via E-mail Via E-mail/SMSGraphic monitoring via animated views (integrated graphic editor)–Graphic monitoring via animated Web pages created by the user– Arithmetic and logical scriptsAlarm notification by E-mailAlarm notification by E-mail/SMS– Data logging in the module with time stamping (CSV files)– Direct recording in SQL, Oracle, MySQL database servers3456– Dynamic HTML report management– Management of “Recipe” data (storage and revad locally or on remote database)– –7Web DesignerSupplied with each module89TSXETG1000 TSXETG1010 TSXETG3000 TSXETG3010 (Modem RTC) TSXETG3021Modem GSM/GPRS(Bands 900/1800MHz)TSXETG3022Modem GSM/GPRS(Bands 850/1900 MHz)10Other versions: please consult our Customer Care Centre.8/23


PreventaThe Preventa range enhances safetythroughout a machine’s entire life cyclefrom design, manufacture, installation,adjustment, operation and servicing rightthrough to decommissioning.In addition to moral obligation andeconomic consequences, the lawrequires that machinery is safe in theinterests of accident prevention.Preventa offers an extensive rangeof safety products, compliant withinternational standards, designedto provide the most comprehensiveprotection for personnel andequipment.Preventa, the safety attitude around your machine life cycleRiskassesmentanalysisMaintennance /Inspection& AuditYourmachineConception& DesignImplementation&Certification


Machine safetyThis document is a selection ofthe top selling products.12Safety standards ..................................................................................................................................9/2 to 9/11Automation ........................................................................................................................................... 9/12 to 9/17Safety PLCsSafety controllers and modules3AS-Interface Safety at work ................................................................................................... 9/18 and 9/19Safety monitors and interfaces4Detection ................................................................................................................................................. 9/20 to 9/27Safety switchesSafety limit switchesCoded magnetic technologySafety matsSafety light curtainsOperator dialogue ............................................................................................................................ 9/28 to 9/32Emergency stopsFoot switchesControl unitsProducts for explosive atmospheres (see chapter 10 “Explosive Atmospheres”)567Motor control .................................................................................................................................. 9/33 to 9/35Switch disconnectorsTeSys motor starters8> New machines - the Machinery DirectiveThe Machinery Directive 98/37/EC is to compel manufacturers to guarantee a minimum safety level for machinery and equipmentsold within the European Union.From 29 December 2009, the new European Machinery Directive 2006/42/EC is effective. Machines have to comply with theEssential Health and Safety Requirements (EHSRs) listed in Annex I of the Directive, thus setting a common minimum level ofprotection across the EEA (European Economic Area).Machine manufacturers, or their authorised representatives within the EU, must ensure that the machine is compliant, theTechnical File can be made available to the enforcing authorities on request, the CE marking is affixed, and aDeclaration of Conformity has been signed, before the machine may be placed on the market within the EU.9109/1


Functional safety«Helping you to reach easily your safetymachinery and standard level required»Thanks to directives and standards as guidelines.


Functional safety> Safety integrity level (SIL), Performance level (PL)MACHINES1SAFETY OF SYSTEMS AND EQUIPMENTEN/IEC 61508Functional safety of electrical / electronic /programmable electronic safety-related systemsEN/ISO 13849-1Safety related parts of control systems23EN/IEC 62061Machine safetyFunctional safety of control electrical / electronic /programmable electronic safety-related systems4Risk reduction according to EN/IEC 61508 and EN/ISO 13849-1• Safety is achieved by risk reduction (for those hazards that cannot be designed-out).• Residual risk is the risk remaining after protective measures have been taken.• Protective measures realised by E/E/PE* safety related systems contribute to risk reduction.* Electric / Electronic / Programmable electronic567RESIDUALRISKTOLERABLERISKEQUIPMENT UNDERCONTROL RISK8Necessary risk reductionActual risk reductionPractical risk coveredby other technologysafety-relatedsystemsPractical risk coveredby electrical / electronic /programmable electronicsafety-related systemsPractical risk coveredby external riskreduction facilities9Risk reduction achieved by all safety-related systemsand external risk reduction facilities109/3


1Functional safety of machinery> Approach according to EN/IEC 62061Risk estimation for SIL assignmentRisk related tothe identifiedhazardSeverity ofthe possibleharmFrequency and duration of exposureProbability of occurrence of a hazardous eventProbability of avoiding or limiting harmFrPrAvProbability ofoccurrence ofthat harm2Example of SIL assignmentThis assignment should be carried by determining the risk parameters that are shown below in an example.3ConsequencesSeverity (Se)Irreversible: death, losing an eye or arm 4Irreversible: broken limb(s), losing a finger(s)3Reversible: requiring attention from a medical practitioner 2Reversible: requiring first aid14Frequency and duration of exposure (Fr)Frequency of exposure> 10 min1 h> 1 h to 1 day55> 1 day to 2 weeks4> 2 weeks to 1 year 3> 1 year 2Probability of occurrenceVery highProbability (Pr)5Likely4Possible 3Rarely2Negligible 1Probability of a voiding or limiting harm (Av)Impossible 5Rarely 3Probable15Serial no.12HazardHazard <strong>XS</strong>e Fr Pr Av CI4 5 + 4 + 3 = 12678ConsequencesDeath, losing an eye or armPermanent, losing fingersReversible, medical attentionReversible, first aid(Se)43213-4SIL 2Class CI5-7SIL 2OM8-10 11-13 14-15SIL 2SIL 1OMSIL 3SIL 3SIL 2SIL 1OMSIL 3SIL 2SIL 1Frequency and durationFr 1 h to 1 day to 10 -8 to 10 -7 to 10 -6 to


Approach according to EN/ISO 13849-1Determination of the Performance Level requested (PLr)Requiredperformancelevel PLrDone using the risk graphic oppositeS = Severity of injuryS1 = Slight (normally reversible injury)S2 = Serious (normally irreversible) injury including deathF = Frequency and/or exposure time to the hazardF1 = Seldom to less often and/or the exposure time is shortF2 = Frequent to continuous and/or the exposure time is longP = Possibility of avoiding the hazard or limiting the harmP1 = Possible under specific conditionsP2 = Scarcely possibleL = Low contribution to risk reductionH = High contribution to risk reductionStarting point forthe evaluation of thecontribution to therisk reduction of asafety function123Determination of the PL achieved by theSafety-related parts of control systems (SRP/CS)According to standard EN/ISO 13849-1,the Performance level (PL) is linked to a targetfailure value of probability of dangerous failureper hour for each safety related control function.Performancelevel (PL)abcdeProbability of a dangerousFailure per Hour10 -5 ... < 10 -43 x 10 -6 ...


1Certified solutions for the safety circuit,designed for you by one of the leadingautomation companies!The concept:Its are made by:2Providing certified safety functions, on thebasis of an approved combination of productsand simplified schematic, to save tie, reducecosts and obtain certification in accordancewith the new European Machinery Directive.> Layout of solution indicating performance level (PL) and safetyintegrity level (SIL)> Bill of materials and the system description file> Example description of the PL and SIL calculation for the safetyfunction> Safety conceptual principle diagram> Certification of all the product combination from a notify body3Safe torque off (PL c, SIL 1) Light curtain (PL c, SIL 1)4567Safe stop 0 (PL d, SIL 2) Safe stop 1 (PL d, SIL 2)89109/6Other versions: please consult our Customer Care Centre.


Safe Stop 1 (PL e, SIL 3) Safety Mat (PL d, SIL 2)12Magnetic switches (PL e, SIL 3) Zero speed detection (PL e, SIL 3)345Multifunction (PL e, SIL 3) AS-i safety (PL e, SIL 3)678Be confident by using certified safety chainsolutions provided by an automation leader> Save cost by avoiding external safety experts engineering> Reduce design time by our examples of calculation of the safetylevel for each safety functionApprovedSafety chain solutionsto achieve the safetylevel required910Other versions: please consult our Customer Care Centre.9/7


Save cost and time with our Preventa offer...12345Safe signal transmission6Acquire the information:Monitor and processing:78Monitoring devices> Monitoring devices used in protection systems to controlaccess to hazardous areas.> Light curtains and safety mats for detecting intrusion intohazardous areas.> Two hand control stations and enabling switchesfor starting and enabling of dangerous movements.> Generic protective measures - Emergency stop.> Safety modules for controlling input signals provenancefrom monitoring devices and acting as an interface withcontactors and variable speed drives used to stop themachine.> Safety controller: Configurable safety device capable ofcentralising a number of safety functions.> Safety PLCs: programmable electronic systems to carryout safety or non-safety related tasks for machinery andequipment.> «As-i safety at work»: fieldbus network certified towork with monitoring devices in order to provide safetyfunctions.9Light curtainsSafety matsTwo hand control stationsand enabling switches10SafetyrelaysSafetyControllerSafetyPLCsAS-i safetyat workEmergency stopTripwire switch9/8Other versions: please consult our Customer Care Centre.


1234Stop the machine:> Contactors with mirror-type auxiliary contacts: mechanically linkedto switch off the motor power supply and provide the feedback loop forthe diagnostics via the safety modules.> Variable Speed Drives and Servodrives controlled stopping of thedangerous movement by safety power removal function integrated.> Disconnect switches with rotary handle: perform an emergencystop by switching off the power supply directly and isolating alldevices.1 Complete& upgradedsafety offer:Improve safety levelrequirementReduce installation timeby easy and quick wiringUp to 50%of spaceoptimizationSave money and optimisespace in enclosures.5678VariableSpeed DrivesServodrivesContactorsRotary switchdisconnectorsSave upto 30%on installationtimeUsing the spring terminaloption included in our newrange of products.910Other versions: please consult our Customer Care Centre.9/9


The Protect Area Design software1234Protect Area Design software is a configurator that enablesselection of the zone protection device like sensing matsrequired for safety applications.This software enables the user, via a graphic interface, tocreate, test or modify a safe working area in the vicinity of apotentially dangerous machine.Having established the predefined fields (safety level of thecontrol system, dimensions of the machine, etc.), the ProtectArea Design software calculates the safety distance in relationto the reaction time of the machine and the approachdirection to the hazardous zone. It then displays a recommendedsafety protection solution and creates the list ofproducts (references, quantities and accessories to be used).Protect Area Design software is user-friendly and compatiblewith Windows 98, NT, 2000 and XP.5678Protect Area DesignSafety mats configuration softwareThe Protect Area Design software enables determination of the shape tobe covered and optimisation of the use of mats using proposed solutionssuch as “Coverage of the zone to be protected” or “Optimised coverageof the zone to be protected”.b For configuration in “Assisted procedure” mode the software enablesaccess to the following menus:v description of the installation: description of the machine, reaction time,v description of the structure and access to the hazardous zone,v selection of configuration according to the zone to be covered,v calculation.b For configuration in “Unassisted procedure” mode the software enablesaccess to the following menus:v replacement of an existing installation,v selection of surface to cover and measurements.910Before using the configurator, it is necessary to perform thefollowing 2 procedures:risk assessment and risk reduction in accordance withEN/ISO 12100-1, in order to decide the contribution of therisk from safety mat and to select the appropriate controlsystem category.9/10Other versions: please consult our Customer Care Centre.


Notes12345678910Other versions: please consult our Customer Care Centre.9/11


PreventaAutomationSafety PLCsCompactFor all XPSMF PLCs1p Maximum category of the solution ..................................Category 4(EN 954-1)p Max performance level for the solution ..........................PL e(EN ISO 13849-1)p Max safety integrity level for the solution ........................SIL 3(EN IEC 62061)Safety PLC typeCompact234Number of inputs/outputs Digital (configurable with XPSMFWIN software) 24Pulsed (1)2x4Memory capacity Application 250 KbData250 KbSupply External 24 VDC supply (with separate protection conforming to IEC 61131-2)Communication On Ethernet network with safe Ethernet protocol Integrated (2xRJ45) Integrated (2xRJ45) Integrated (2xRJ45) Integrated (2xRJ45) Integrated (2xRJ45) Integrated (2xRJ45)On Modbus TCP/IP – Integrated (2xRJ45) – Integrated (2xRJ45) – Integrated (2xRJ45)On Modbus (Serial link) – – Integrated (1xRJ45) Integrated (1xRJ45) – –On Profibus DP – – – – Integrated (SUB-D9) Integrated (SUB-D9)Input/output connectionsRemovable screw terminal blocks or removable cage clamp terminal blocks coded with locating deviceReferences XPSMF4000 XPSMF4002 XPSMF4020 XPSMF4022 XPSMF4040 XPSMF4042(1) They outputs are not safety outputs.5Compact6789Safety PLC typeCompactNumber of inputs Digital 20 20 24 24 24Analogue – – 8 8 8Counting – – 2 2 2Number of outputs Digital 8 8 8 8 8Analogue – – – – –Relay – – – – –Memory capacity Application 250 KbData250 KbSupply External 24 VDC supply (with separate protection conforming to IEC 61131-2)Communication On Ethernet network (Modbus TCP/IP) Integrated (4xRJ45) Integrated (4xRJ45) Integrated (4xRJ45) Integrated (4xRJ45) Integrated (4xRJ45)On Modbus (Serial link) Integrated (SUB-D9) – – Integrated (SUB-D9) –On Profibus DP – – – – Integrated (SUB-D9)Input/output connectionsRemovable screw terminal blocks, coded with locating deviceReferences (2) XPSMF3022 XPSMF31222 XPSMF3502 XPSMF3522 XPSMF3542(2) Products referenced XPSMF30/MF31/MF35 are marked Himatrix F30, F31 and F35.109/12Autres réalisations : consulter votre centre de relation clients


For all XPSMF PLCsp Maximum category of the solution ..................................Category 4(EN 954-1)p Max performance level for the solution ..........................PL e(EN ISO 13849-1)p Max safety integrity level for the solution ........................SIL 3(EN IEC 62061)Type CPU Power supply RackSoftwaremodulewith 6 slotsMemory capacity Application 500 Kb – – For XPSMF PLCsData 500 Kb – –Supply – External 24 VDC, integrated –Communication On Ethernet network (Modbus TCP/IP) Integrated (4xRJ45) – – Complete versionOn Modbus bus (Serial link) Integrated (SUB-D9) – – SSV1XPSMFWINPower connections Screw terminal blocks Screw terminal blocks – (1)Dimensions W x D x H – – 257 x 239 x 310 mm Update versionReferences XPSMFCPU22 XPSMFPS01 XPSMFGEH01 SSVXPSMFWINUP123I/O module typeFor modular safety PLCAnalogue Digital RelayNumber of inputs Digital – – – 24 32 24 –Analogue 8 – – – – – –Counting – – 2 – – – –Number of outputs Digital – – 4 – – 16 –SupplyAnalogue – 8 – – – – –Relay – – – – – – 8Removable screw terminal blocks, coded with locating deviceReferences XPSMFAI801 XPSMFAO801 XPSMFCIO2401 XPSMFDI2401 XPSMFDI3201 XPSMFDIO241601 XPSMFDO801Decentralised safety I/O modules456Module typeInputs/OuputsDigitalNumber of inputs Digital 16 8+2 16 20Number of outputs Digital – 8 8 8Pulsed 4 2 2 –Supply External 24 VDC supply (with separate protection conforming to IEC 61131-2)Communication On Safe Ethernet network (Modbus TCP/IP) Integrated (2xRJ45)Input/output connectionsRemovable screw terminal blocks, coded with locating deviceReferences (2) XPSMF1DI1601 XPSMF3DIO8801 XPSMF3DIO16801 XPSMF3DIO2080278I/O module typeInputs/Outputs OutputsAnalogue DigitalRelayNumber of inputs Analogue 8 – – – –Number of outputs Digital – 4 16 – –Analogue (not safety) 4 – – – –Relay – – – 8 16Supply External 24 VDC supply (with separate protection conforming to IEC 61131-2)Communication On Safe Ethernet network (Modbus TCP/IP) Integrated (2xRJ45)Input/output connectionsRemovable screw terminal blocks, coded with locating deviceReferences (2) XPSMF3AIO8401 XPSMF2DO401 XPSMF2DO1601 XPSMF2DO801 XPSMF2DO1602(1) To be ordered only if the previous version of have been already installed.(2) Products referenced XPSMF1/MF2/MF3 are marked Himatrix F1, F2 and F3.910Other versions: please consult our Customer Care Centre.9/13


PreventaAutomationSafety controllers for monitoringemergency stops and limit switches12Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)UniversalPL e / Cat. 4, SILCL 3Number of circuits Safety 2 x 2N/O + 6 solid-state 2 x 3N/O per functionAdditional – 3 solid-stateDisplay (number of LEDs) 30 12Width of housing 74 mm 45 mmCommunication interface Modbus Modbus, CANopen Modbus, Profibus DP –3Universal solutions: safety controllers (for monitoring several safety functions simultaneously)Supply voltage 24 VDC XPSMC32Z (1) (2) XPSMC32ZC (1) (2) XPSMC32ZP (1) (2) XPSMP11123P (3)coded magnetic switchesenabling switch4Universal56Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL e / Cat. 4, SILCL 3For monitoringmagnetic switches and enabling switchNumber of circuits Safety 2 x 2N/O + 6 solid-state 2 x 3N/O per functionAdditional – 3 solid-stateDisplay (number of LEDs) 30 12Width of housing 74 mm 45 mmCommunication interface Modbus Modbus, CANopen Modbus, Profibus DP –Universal solutions: safety controllers (for monitoring several safety functions simultaneously)Supply voltage 24 VDC XPSMC32Z (1)(2) XPSMC32ZC (1)(2) XPSMC32ZP (1)(2) XPSMP11123P (3)7safety mats and edging8Universal910Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL d / Cat. 3, SILCL 2Number of circuits Safety 2 x 2N/O + 6 solid-state 2 x 3N/O per functionAdditional – 3 solid-stateDisplay (number of LEDs) 30 12Width of housing 74 mm 45 mmCommunication interface Modbus Modbus, CANopen Modbus, Profibus DP –Universal solutions: safety controllers (for monitoring several safety functions simultaneously)Supply voltage 24 VDC XPSMC32Z (1)(2) XPSMC32ZC (1)(2) XPSMC32ZP (1)(2) XPSMP11123P (3)(1) Version with 32 inputs. For version with 16 inputs, replace 32 in the reference by 16 (example: XPSMC32Z becomes XPSMC16Z).(2) Configuration software XPSMCWIN (complete version) or SSVXPSMCWINUP (update version), connecting cable, adaptor and set of screw terminal plug-in connectorsXPSMCTS16 and XPSMCTS32 or set of spring clip terminal plug-in connectors XPSMCTC16 and XPSMCTC32 to be ordered separately.(3) For fixed connector version, delete the letter P from the end of the reference (example: XPSMP11123P becomes XPSMP11123).9/14Other versions: please consult our Customer Care Centre.


Safety modules for monitoringemergency stops and limit switchesNewNewMaximum safety level of the solution attained PL e / Cat. 4, SILCL 3(EN ISO 13849-1, EN/IEC 62061)Number of circuits Safety 3 N/O 3N/O 3 N/O 3 N/O 7 N/O 3N/O + 3N/Otime del.2N/O + 1N/Otime del.2N/O + 3N/Otime del.Additional 1 solid-state 1 N/C – 1 N/C 2 N/C 3 solid-state – 4 solid-state+ 4 solid-state + 4 solid-stateDisplay (number of LEDs) 2 2 3 4 4 11 3 4Width of housing 22.5 mm 22.5 mm 22.5 mm 45 mm 90 mm 45 mm 22.5 mm 45 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage (1) 24 VDC – – – – XPSAV11113P XPSABV11330P (2) –24 VAC/DC XPSAC5121P XPSAXE5120P (2) XPSAF5130P XPSAK311144P XPSAR311144P – – XPSATE5110P230 VAC – – – – – – – XPSATE3710P(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSAV11113P becomes XPSAV11113).(2) For a version with spring terminals, replace the letter P with the letter C at the end of the reference (example: XPSAXE5120P becomes XPSAXE5120C)coded magnetic switchesenabling switch1234Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL e / Cat. 4, SILCL 3For monitoring 2 coded magnetic 6 coded magnetic enabling switchswitches maximumswitches maximumNumber of circuits Safety 2N/O 2N/O 2N/OAdditional 2 solid-state 2 solid-state 2 solid-stateDisplay (number of LEDs) 3 15 3Width of housing 22.5 mm 45 mm 22.5 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage 24 VDC XPSDMB1132P (1) XPSDME1132P (1) XPSVC1132P (1)(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSDMB1132P becomes XPSDMB1132).567safety mats and edging8Maximum safety level of the solution attained PL d / Cat. 3, SILCL 2(EN ISO 13849-1, EN/IEC 62061)Number of circuits Safety 3N/OAdditional1N/C + 4 solid-stateDisplay (number of LEDs) 4Width of housing45 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage 24 VAC/DC XPSAK311144P (1)(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSAK311144P becomes XPSAK311144).910Other versions: please consult our Customer Care Centre.9/15


1,00,80,60,40,20,0PreventaAutomationSafety controllers for monitoringtwo-hand control12Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)UniversalPL e / Cat. 4, SILCL 3Number of circuits Safety 2 x 2N/O + 6 solid-stateAdditional –Display (number of LEDs) 30Width of housing74 mmCommunication interface Modbus Modbus, CANopen Modbus, Profibus DP3Universal solutions: safety controllers (for monitoring several safety functions simultaneously)Supply voltage 24 VDC XPSMC32Z (1)(2) XPSMC32ZC (1)(2) XPSMC32ZP (1)(2)light curtains4Universal567Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL e / Cat. 4, SILCL 32 light curtainsmonitoring max.Number of circuits Safety 2 x 2N/O + 6 solid-state 2x3N/O per function 6 PNP solid-stateAdditional – 3 solid-state 1 PNP + 1 NPNDisplay (number of LEDs) 30 12 14 + double display unitsWidth of housing 74 mm 45 mm 100 mmIntegral Muting function Yes No YesCommunication interface Modbus Modbus, CANopen Modbus, Profibus DP – –Universal solutions: safety controllers (for monitoring several safety functions simultaneously)Supply voltage 24 VDC XPSMC32Z(1)(2) XPSMC32ZC(1)(2) XPSMC32ZP(1)(2) XPSMP11123P (3) XPSLCM1150 (4)(1) Version with 32 inputs, for version with 16 inputs, replace 32 in the reference by 16 (example: XPSMC32Z becomes XPSMC16Z).(3) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSMP11123P becomes XPSMP11123).(4) Removable terminal blockszero speed, time delay8Universal910Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL e / Cat. 4, SILCL 3For monitoringMotor zero speed conditionNumber of circuits Safety 2 x 2N/O + 6 solid-stateAdditional –Display (number of LEDs) 30Width of housing74 mmCommunication interface Modbus Modbus, CANopen Modbus, Profibus DPUniversal solutions: safety controllers (for monitoring several safety functions simultaneously)Supply voltage 24 VDC XPSMC32Z (5) (2) XPSMC32ZC (5) (2) XPSMC32ZP (5) (2)(2) Configuration software XPSMCWIN (complete version) or SSVXPSMCWINUP (update version), connecting cable, adaptor and set of screw terminal plug-in connectorsXPSMCTS16 and XPSMCTS32 or set of spring clip terminal plug-in connectors XPSMCTC16 and XPSMCTC32 to be ordered separately.(5) Plug-in connector version only.9/16Other versions: please consult our Customer Care Centre.


1,00,80,60,40,20,0Safety modules for monitoringtwo-hand controlNewMaximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL c / Cat. 1 PL e / Cat. 4, SILCL 3(type IIIA to EN 574/ISO 13851) (type IIIC to EN 574/ISO 13851)Number of circuits Safety 1N/O 2N/O 2N/OAdditional 1N/C 1N/C 2 solid-stateDisplay (number of LEDs) 2 3 3Width of housing 22.5 mm 22.5 mm 22.5 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage 24 VDC – – XPSBF1132P (1)24 VAC/DC XPSBA5120 XPSBCE3110P (2) –(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSBF1132P becomes XPSBF1132).(2) For version with cage clamps removable terminal block, change the letter P for C from the end of the reference (example: XPSBCE3110P becomes XPSBCE3110C)123light curtains4Maximum safety level of the solution attainedPL c / Cat. 2, SILCL 1 PL e / Cat. 4, SILCL 3(EN ISO 13849-1, EN/IEC 62061)Number of circuits Safety 2N/O 3N/O 3N/O 7N/OAdditional 4 solid-state – 1N/C + 4 solid-state 1N/C + 4 solid-stateDisplay (number of LEDs) 4 3 4 4Width of housing 45 mm 22.5 mm 45 mm 90 mmIntegral Muting function Yes No No NoOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage 24 VDC XPSCM1144P (1) – – –24 VAC/DC – XPSAFL5130P (1) XPSAK311144P (1) XPSAR311144P (1)(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSCM1144P becomes XPSCM1144).zero speed, time delay and liftsNew5678Maximum safety level of the solution attainedPL d / Cat. 3, SILCL 2 PL e / Cat. 4, SILCL 3(EN ISO 13849-1, EN/IEC 62061)For monitoring Motor zero speed condition Safety time delay LiftsNumber of circuits Safety 1N/O + 1N/C 1N/O time delay 1N/O pulse 2N/OAdditional 2 solid-state 2N/C + 2 solid-state 2N/C + 2 solid-state 2 solid-stateDisplay (number of LEDs) 4 4 4 4Width of housing 45 mm 45 mm 45 mm 22.5 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage 24 VDC XPSVNE1142P (1) – – –24 VAC/DC – XPSTSA5142P (2) XPSTSW5142P (2) XPSEDA5142(1) Motor frequency ≤ 60 Hz.. For frequencies ≥ 60 Hz, please refer to the “Safety solution” catalogue.(2) Removable terminal block version only.910Other versions: please consult our Customer Care Centre.9/17


PreventaAS-Interface safety at workSafety monitorsMonitors123Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL e / Cat. 4, SILCL 3Number of circuits Safety 2N/O 2 x 2N/OAuxiliary 1 solid-state 2 solid-stateDisplay (number of LEDs) 5 8Width of housing 45 mm 45 mmAS-Interface profile S.7.F S.7.FMaster module compatibility V1 / V2.1 V1 / V2.1References of monitor with enhanced functions ASISAFEMON1B ASISAFEMON2Bstandard functions ASISAFEMON1 ASISAFEMON24Configuration software, adjustment terminal andAS-Interface analyser5Type Configuration software (1) Adjustment terminal (2) AS-Interface Analyser678Multilingual EN / FR / DE / ES / IT / PT – b Analysis and diagnostics of AS-InterfaceFor use with ASISAFEMON1/2, – line and Safety at WorkASISAFEMON1B/2B b Complements the diagnostic functions ofMedia CD-ROM PC – the local AS-Interface masterEnvironment Windows – b Maintenance or validation of AS-InterfaceDegree of protection – IP 40 linesSupply – 4 x LR6 batteries b Print-out of AS-Interface line testsDimensions W x D x H – 70 x 50 x 170 mm 92 x 28 x 139 mmReferences Complete version ASISWIN2 ASITERV2 ASISA01Update version (3) SSVASISWINUP – –(1) CD-ROM with hardware and software user guides.(2) For addressing safety interfaces, use the infrared adaptor ASITERIR1 or the standard adaptor ASISAD1.(3) To be ordered only if a previous version of ASISWIN have been already installed.Accessories910TypeAdaptor Infrared adaptor Tap-off CableCablefor the adressingof safety interfacesfor adjustment terminal for AS-Interface cable for monitorparametering, RS 232for monitor to monitortransferDegree of protection – IP 67 IP 67 IP 20 IP 20Cable length – 1 m 2 m 2 m 0.2 mReferences ASISAD1 ASITERIR1 TCSATN01N2 ASISCPC ASISCM9/18Other versions: please consult our Customer Care Centre.


Safety interfacesFor Ø 22 Emergency stop1Interface type For mushroom head pushbuttons Control stationsMetal (1) Plastic (1) PlasticDegree of protection IP 20 IP 20 IP 20 IP 20 IP 65 IP 65Dimensions W x D x H (mm) 40 x 90 x 68 40 x 80 x 40 40 x 90 x 64 40 x 90 x 40 66 x 95 x 78 66 x 95 x 78AS-Interface profile S.0.B.F.F S.0.B.F.F S.0.B.F.F S.0.B.F.F S.0.B.F.F S.0.B.F.FConsumption from AS-Interface 45 mA 45 mA 45 mA 45 mA 45 mA 45 mAInfrared addressing Yes No Yes No No NoConnection on AS-Interface IDC (2) Connector IDC (2) Connector M12 connector M12 connectorReference with N/C + N/C contact (head not included) ASISSLB4 ASISSLE4 ASISSLB5 ASISSLE5 ASISEA1C ASISEK1CReference of head (Ø40 latching mushroom head, turn to release) ZB4BS844 (3) ZB4BS844 (3) ZB4AS844 (3) ZB5AS844 (3) Integrated (4) Integrated (5)(1) For installation in enclosures.(2) IDC: Insulation Displacement Connector.(3) Head to be ordered separately. For other heads, please refer to www.schneider-electric.com.(4) Turn to release latching mushroom head.(5) Key release (n° 455) latching mushroom head.For other safety products withM12 connector outputs or ISO M16/202345Type of entry 2 x M12 entries (6) 1 x M12 entry 1 x ISO M16 entry (7)Degree of protection IP 67 IP 67 IP 67Dimensions W x D x H 40 x 40 x 58 mm 40 x 40 x 58 mm 40 x 40 x 57.5 mmAS-Interface profile S.0.B.F.F S.0.B.F.F S.0.B.F.FConsumption from AS-Interface 45 mA 45 mA 45 mAInfrared addressing Yes Yes YesConnection on AS-Interface IDC (1) IDC (1) IDC (1)References ASISSLC2 ASISSLC1 ASISSLLS(6) For connection using 2 pre-wired connectors, or 1 pre-wired connector + 1 connector.(7) For 1 x ISO M20 entry, use adaptor shown below.67Accessories89TypeTap-off forAS-Interface cableConnectorsPre-wiredconnectorAdaptor(sold in lots of 5)Description M12 female, threaded elbowed straight straight ISO M16/M20Degree of protection IP 67 IP 67 IP 67 IP 67 IP 67Length of cable – – – 2 m –References TCSATN011F XZCC12MCM40B XZCC12MDM40B XZCP1541L2 DE9RI201610Other versions: please consult our Customer Care Centre.9/19


111222 21PreventaDetectionIllustration of contacts with the actuatorinserted in the head of the switchISO entry(to EN 50262)Safety switchesand actuators3012345678131422 212-pole contactSlow break(1NC+1NO)2-pole contactSlow break(2NC)3-pole contactSlow break(1NC+2NO)3-pole contactSlow break(2NC+1NO)6020/22Without lockingPlastic, double insulated switches Type XCSMP Type XCSPA and TA Type XCSLEpre-cabled, L = 2 m 1xISO M16 entry. (2) 2xISO M16 entries. (2) 3 x ISO M20 cable entriesActuation speed (min → max) 0,05 m/s → 1,5 m/s 0,1 m/s → 0,5 m/s 0,1 m/s → 0,5 m/sDegree of protection IP 67 IP 67 IP 67 + IP 66Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, C 300 / DC 13, Q 300 AC 15, A 300 / DC 13, Q 300 AC 15, B 300 / DC 13, Q 300Dimensions (body + head) W x D x H 30 x 15 x 87 mm 30 x 30 x 93,5 mm 52 x 30 x 114,5 mm 43.5 x 51 x 205 mmSolenoid supply voltage – – – 24 VAC/DCComplete switch 1NC+1NO break before make, slow break XCSMP59L2 (3) XCSPA592 – XCSLE25253122NC slow break XCSMP79L2 (3) XCSPA792 – XCSLE27273121NC+2NO break before make, slow break XCSMP70L2 (3) XCSPA892 XCSTA592 XCSLE35353121NC+2NO snap action – – – –2NC+1NO break before make, slow break XCSMP80L2 (3) XCSPA992 XCSTA792 XCSLE37373122NC+1NO snap action – XCSPA492 – –3-pole contactSlow break(1NC+2NO)3020/2240,320/22(1) For locking on energisation of solenoid, please refer to www.schneider-electric.com.(2) With entry for n° 11 (Pg 11) cable gland, replace the last digit in the reference by 1 (example: XCSPA592 becomes XCSPA591).(3) For other models, please refer to www.schneider-electric.com.Metal switches3-pole contactSlow break(2NC+1NO)Illustration of contactswith the actuatorinserted in the headWithout locking With interlocking, manual unlockingof the switchBy button By key lock Locking on de-energisation of solenoid (1)Type XCSA/B/C1 x ISO M20 cable entry (2)Type XCSLF3 x ISO M20 cable entriesActuation speed (min → max) 0.1 m/s → 0.5 m/s 0.1 m/s → 0.5 m/sDegree of protection IP 67 IP 67 + IP 66Locking on de-energisationof solenoid (1)Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300 AC 15, B 300 / DC 13, Q 300Dimensions (body + head) W x D x H 40 x 44 x 113.5 mm 52 x 44 x 113.5 mm 52 x 44 x 113.5 mm 43.5 x 51 x 205 mmSolenoid supply voltage – – – 24 VAC/DC 24 VAC/DCComplete switch 1NC+2NO break before make, slow break XCSA502 XCSB502 XCSC502 XCSLF3535312 XCSLF3535412 (3)2NC+1NO break before make, slow break XCSA702 XCSB702 XCSC702 XCSLF3737312 XCSLF3737412 (3)1NC+1NO break before make, slow break2NC snap breakISO entry(to EN 50262)(1) For locking on energisation of solenoid, please refer to www.schneider-electric.com.(2) With entry for n° 13 (Pg 13.5) cable gland, replace the last digit in the reference by 1 (example: XCSA502 becomes XCSA501).(3) With mushroom head emergency release button.AccessoriesXCSLF2525312XCSLF2727312Straight actuator Right-angled actuator Pivoting actuator, RH door Pivoting actuator, LH doorFor safety switches XCSMPActuatorsReferences XCSZ81 XCSZ84 XCSZ83 XCSZ85153.330Available2Q 2011153.3153.330910Straight actuator Wide actuator L=40 mm (1) Right-angled actuator Pivoting actuator Guard/door retainerFor safety switches XCSPA/TA/TE Actuators Retaining deviceReferences XCSZ11 XCSZ12 XCSZ14 XCSZ13 XCSZ21(1) For L = 29 mm, reference = XCSZ15.Straight actuator Wide actuator Pivoting actuatorFor safety switches XCSA/B/C/LE/LF Actuators Door lockReferences XCSZ01 XCSZ02 XCSZ03 XCSZ059/20Other versions: please consult our Customer Care Centre.


121122 21Safety switcheswith rotary lever or spindleISO entry(to EN 50262)131422 212-pole contactSlow break(1NC+1NO)20/222-pole contactSlow break(2NC)Stainless steel, elbowed (flush with rear of switch) lever Stainless steel straight lever Stainless steelLever to left Lever centred Lever to right Lever to left or right Lever centred spindle, L = 30 mmPlastic switchesType XCSPL with rotary lever or XCSPR with spindle1 x ISO M16 cable entry (1)Minimum torque (actuation / positive opening)0,1 / 0,25 N.mDegree of protection IP 67Rated operational characteristics AC 15, A 300 / DC 13, Q 300 (selon EN IEC 60947-5-1)Dimensions (body + head) W x D x H 30 x 30 x 160 mm 30 x 30 x 96 mmTripping angle 5°Complete switch 1NC+1NO break before make, slow break XCSPL592 XCSPL582 XCSPL572 XCSPL562 XCSPR5522NC slow break XCSPL791 (2) XCSPL781 (2) XCSPL771 (2) XCSPL762 XCSPR7521NC+2NO break before make, slow break – – – XCSPL862 –2NC+1NO break before make, slow break – XCSPL981 (2) – XCSPL962 XCSPR952(1) With entry for n° 11 (Pg 11) cable gland, replace the last digit in the reference by 1 (example: XCSPL592 becomes XCSPL591).(2) For entry for ISO M20 cable gland, also order adaptor DE9RA1620 (sold in lots of 5).1233-pole contactSlow break(1NC+2NO)ISO entry(to EN 50262)40,320/224Plastic switches3-pole contactSlow break(2NC+1NO)Stainless steel, elbowed (flush with Stainless steel straight lever Stainless steel spindlerear of switch) lever - Lever centred Lever centredLength 30 mmType XCSTL with rotary lever or XCSTR with spindle2 x ISO M16 cable entries (1)Minimum torque (actuation / positive opening)0.1 / 0.45 N.mDegree of protection IP 67Rated operational characteristics AC 15, A 300 / DC 13, Q 300 (conforming to EN IEC 60947-5-1)Dimensions (body + head) W x P x H 52 x 30 x 180 mm 52 x 30 x 117 mmTripping angle 5°Complete switch 1NC+2NO break before make, slow break XCSTL582 XCSTL552 XCSTR5522NC+1NO break before make, slow break XCSTL782 XCSTL752 XCSTR752(1) With entry for n° 11 (Pg 11) cable gland, replace the last digit in the reference by 1 (example: XCSTL582 becomes XCSTL581).5678910Other versions: please consult our Customer Care Centre.9/21


PreventaDetectionLimit switchesSafety limit switches123BK-WH BKBK-WH BKRD-WH RDRD-WH RDBUBNBUBNGN-YEGN-YEMiniature switches3-pole contact2NC+1NOSnap action3-pole contact2NC+1NOSlow breakMetal Roller plunger Thermoplasticend plungerroller leverType XCSM, metalpre-cabled, L = 1 m (1)Maximum actuation speed 0.5 m/s 0.5 m/s 1.5 m/sMinimum force or torque (actuation / positive opening) 8.5 N / 42.5 N 7 N / 35 N 0.5 N.m / 0.1 N.mDegree of protection IP 66 + IP 67 + IP 68 IP 66 + IP 67 + IP 68 IP 66 + IP 67 + IP 68Dimensions (body + head) W x D x H 30 x 16 x 60 mm 30 x 16 x 70.5 mm 30 x 32 x 92.5 mmComplete switch 2NC+1NO snap action XCSM3910L1 XCSM3902L1 XCSM3915L12NC+1NO slow break XCSM3710L1 XCSM3702L1 XCSM3715L1(1) For a 2 m long cable, replace the last digit of the reference by 2 (example: XCSM3910L1 becomes XCSM3910L2).For a 5 m long cable, replace the last digit of the reference by 5 (example: XCSM3910L1 becomes XCSM3910L5).456783-pole contact2NC + 1NOSnap action3-pole contact2NC + 1NOSlow breakMetal Roller Thermoplastic Metal Roller Thermoplasticend plunger plunger roller lever end plunger plunger roller leverCompact switches Type XCSD, metal Type XCSP, plastic1 x ISO M20 x 1.5 cable entry (2) 1 x ISO M20 x 1.5 cable entry (2)Maximum actuation speed 0.5 m/s 1.5 m/s 0.5 m/s 1.5 m/sMinimum force or torque (actuation / positive opening) 15 N / 45 N 12 N / 36 N 10 N.m / 0.1 N.m 15 N / 45 N 12 N / 36 N 10 N.m / 0.1 N.mDegree of protection IP 66 + IP 67 IP 66 + IP 67Dimensions (body + head) W x D x H (mm) 34 x 34.5 x 89 34 x 34.5 x 99.5 34 x 43 x 121.5 34 x 34.5 x 89 34 x 34.5 x 99.5 34 x 43 x 121.5Complete switch 2NC+1NO snap action XCSD3910P20 XCSD3902P20 XCSD3918P20 XCSP3910P20 XCSP3902P20 XCSP3918P202NC+1NO slow break XCSD3710P20 XCSD3702P20 XCSD3718P20 XCSP3710P20 XCSP3702P20 XCSP3718P20(2) For Pg 13.5 and 1/2" NPT cable entries, refer to www.schneider-electric.com.9109/22Other versions: please consult our Customer Care Centre.


PreventaDetection(1) (1)Coded magnetic technologyPlastic coded magnetic systemF11/BN2 AI1 7/GY +NOO1 4/BKI2 6/PK +NO O2 2/WHK23/BU+XCSDM3K1 6 47 3– 1 21/BN+DiagNONO8/OGEr 7/VTI1 5/GY +O1 4/BKI2 6/PK +O2 2/WHK23/BUK2 K1F12 A+K1+–XCSDM456 47 31 281Type of system SIL2/Category 3 SIL3/Category 4With integrated safety module XCSDM3 XCSDM4Switches for actuationFace to face, face to side, side to sideDegree of protectionPre-cabled: IP66 / IP67, IP69K, connector: IP67Type of contact2 solid-state output PNP/NO, 1,5 A / 24VDC (2 A up to 60°C)Rated operational characteristics Ub: 24 VDC +10% - 20%Dimensions W x D x H34 x 27 x 100 mmOperating zoneSao= 10 mm / Sar= 20 mmReferences Connection for cable L= 2m XCSDM379102 XCSDM480102for cable L= 5m XCSDM379105 XCSDM480105for cable L= 10m XCSDM379110 XCSDM480110for connector M12 XCSDM3791M12 XCSDM4801M12234Coded magnetic5(1) (1)WHBKWHBKBNBUBNBUContact(1NC+1NOstaggered)Contact(2NCstaggered)Plastic switchesPK GYPK GYBK WHBK WHBU BNBU BNContact(1NC+2NO,1NOstaggered)Contact(2NC+1NO,1NCstaggered)Rectangular Rectangular Cylindrical Rectangular Rectangular CylindricalWithout LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2)Type XCSDM coded magneticPre-cabled, L = 2 m Connector on flying lead, L = 10 cm (3)Switches for actuation Face to face, face to side, side to side Face to face Face to face, face to side, side to side Face to faceDegree of protection IP 66 + IP 67 IP 66 + IP 67Type of contact REED REEDRated operational characteristics Ue = 24 VDC, Ie = 100 mA Ue = 24 VDC, Ie = 100 mADimensions W x D x H 16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38,5 mm 16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38.5 mmOperating zone (4) Sao = 5 / Sar = 15 Sao = 8 / Sar = 20 Sao = 5 / Sar = 15 Sao = 8 / Sar = 20Switch with coded magnet 1NC+1NO staggered XCSDMC5902 XCSDMP5902 XCSDMR5902 XCSDMC590L01M8 XCSDMP590L01M12 XCSDMR590L01M122NC staggered XCSDMC7902 XCSDMR7902 XCSDMR7902 XCSDMC790L01M8 XCSDMP790L01M12 XCSDMR790L01M121NC+2NO, 1NO staggered – XCSDMP5002 – – XCSDMP500L01M12 –2NC+1NO, 1NC staggered – XCSDMP7002 – – XCSDMP700L01M12 –(1) Illustration of contacts with the magnet in front of the switch.(2) For version with LED indicator, replace the last 0 in the reference by 1 (example: XCSDMC5902 becomes XCSDMC5912).(3) For associated pre-wired female connectors, please refer to the “Safety solution” catalogue.(4) Sao: assured operating distance. Sar: assured release distance.678910Other versions: please consult our Customer Care Centre.9/23


PreventaDetectionMatsSafety mats1234Maximum safety level achieved by the solution PLd/cat3, SILCL2(EN ISO 13849-1, EN/IEC 62061)Degree of protection IP 67Response time (s)Mat itself: 20 ms, with module: XPSAK ≤ 40 ms, XPSMP < 30 msSensitivitySingle mat > 20 kg / Group of mats > 35 kgMaximum load 2000 N/cm 2Connection (2)By M8 jumper cable (1 male / 1 female), L = 100 mmDimensions W x D x H 500 x 500 x 11 mm 500 x 750 x 11 mm 750 x 750 x 11 mm 750 x 1250 x 11 mmReferences XY2TP1 XY2TP2 XY2TP3 XY2TP4(2) For associated jumper cable and pre-wired connector, please refer to www.schneider-electric.comwww.Schneider-electric.com.AccessoriesRails (set of 2) Length 194 mm 394 mm 444 mm 494 mm 644 mm 694 mm 744 mm 1194 mm 1244 mmReferences XY2TZ10 XY2TZ20 XY2TZ30 XY2TZ40 XY2TZ50 XY2TZ60 XY2TZ70 XY2TZ80 XY2TZ90Corners and rail connectors External corners Internal corner Rail connectors, L = 56 mm Rail connectors, L = 6 mm(set of 4) + external corner with outlet for cable (set of 2) (set of 2)References XY2TZ4 XY2TZ5 XY2TZ1 XY2TZ256Selection guidance software78For safety matsReferenceProtect Area DesignXY2TPDownloadable on Schneider-Electric.com9109/24Other versions: please consult our Customer Care Centre.


Light curtainsType 2 conforming to IEC 61496-2Light curtain functions• Auto/Manual,• Monitoring of external switching devices(EDM: External Devices Monitoring),• LED display of operating modesMaximum safety level achieved by the solutionPLc/cat2(EN ISO 13849-1)TypeMulti-beam, infrared transmissionSlim range Manual starting Automatic startingNominal sensing distance (Sn)0.3…15 mDetection capacity30 mm “hand”Number of safety circuits2 solid-state PNPResponse time (depending on model)14…24 msConnectionM12 ConnectorHeight protected (mm) 150 XUSLNG5D0150 XUSLNG5C0150300 XUSLNG5D0300 XUSLNG5C0300450 XUSLNG5D0450 XUSLNG5C0450600 XUSLNG5D0600 XUSLNG5C0600750 XUSLNG5D0750 XUSLNG5C0750900 XUSLNG5D0900 XUSLNG5C09001050 XUSLNG5D1050 XUSLNG5C10501200 XUSLNG5D1200 XUSLNG5C12001350 XUSLNG5D1350 XUSLNG5C13501500 XUSLNG5D1500 XUSLNG5C1500Accessories12345Cable length 3 m 10 m 30 mPre-wired connector for XUSLN For receiver <strong>XS</strong>ZNCR03 <strong>XS</strong>ZNCR10 <strong>XS</strong>ZNCR30(screened cable)For transmitter <strong>XS</strong>ZNCT03 <strong>XS</strong>ZNCT10 <strong>XS</strong>ZNCT30Type 2 conforming to IEC 61496-1 et 26Light curtain functions• Auto/Manual,• Monitoring of external switching devices(EDM: External Devices Monitoring),• LED display of operating modesType • Integral muting function.Maximum safety level achieved by the solution(EN ISO 13849-1, EN/IEC 62061)TypePLc/cat2, SILCL1Single-beam with infrared emission78Height protected (conforming to prEN 999)750…1200 mm (1 to 4 beams)Nominal sensing distance (Sn)8 mNumber of circuits Safety 2N/OAdditional4 solid-stateResponse time< 25 msModules (integral muting function) 24 VDC XPSCM1144P (1)Thru-beam pairs, Pre-cabled, L = 5m PNP XU2S18PP340L5 (2)axially alignedM12 connector PNP XU2S18PP340D (2)(1) For version with non removable terminal block, delete the letter P from the end of the reference. Example: XPSCM1144P becomes XPSCM1144).(2) For alignment at 90° to the mounting axes, insert the letter W in the reference before the last letter. Example: XU2S18PP340L5 becomes XU2S18PP340WL5).910Other versions: please consult our Customer Care Centre.9/25


PreventaDetectionLight curtainsType 4 conforming to IEC 61496-212345678910Functions accessible by cabling aloneb Automatic startb Auxiliary output (PNP, status signalling)b Alignment aid by display of each light beam brokenb LED display of operating modes and faultsMaximum safety level achieved by the solution PLe/cat4, SILCL3(EN ISO 13849-1, EN/IEC 62061)TypeMulti-beam, infrared transmissionLight curtainsCascadable light curtainsNominal sensing distance (Sn)0,3…7 or 3 m withPDM Box (2)0,3…8 or 20 m withPDM Box (2)0,3…7 or 3 m withPDM Box (2)0,3…20 or 8 m withPDM Box (2)Detection capacity 14 mm "finger" 30 mm "hand" 14 mm "finger" 30 mm "hand"Number of circuits Safety 2 solid-state PNP 2 solid-state PNPAuxiliary (alarm) 1 solid-state PNP 1 solid-state PNP or NPNResponse time (depending on model) 23…41 ms 23…32 ms 23…41 ms 23…32 msConnectionM12 connectorFunctions accessible via programming and diagnostic module b Auto/Manualb Monitoring of external switching devices(EDM: External Device Monitoring)b Test (MTS : Monitoring Test Signal),b Light beam coding (A or B)b Sensing distance (short, long)b Programming and downloading of configurationsettings, via programming and diagnosticmodule (PDM)b Display of operating modes and faults by LEDand/or PDM (2)b Auto/Manual, manual 1st cycleb Monitoring of external switching devices(EDM: External Device Monitoring)b Test (MTS : Monitoring Test Signal),b Blanking (ECS/B), Monitored Blanking,Floating Blanking (FB)b Reduction of resolutionb Response time (normal, slow)b Light beam coding (A or B)b Sensing distance (short, long)b Auxiliary output (alarm or status signalling,PNP or NPN)b Start button (N/O or N/C, 0 V or 24 V)b Mutingb Display of operating modes and faults by LEDand/or PDM (2)Transmitter + receiver (1) Height protected (mm) 280 XUSLBQ6A0280 – XUSLDMQ6A0280 –320 – – XUSLDMQ6A0320 –360 XUSLBQ6A0360 XUSLBR5A0360 – XUSLDMY5A0360440 XUSLBQ6A0440 – XUSLDMQ6A0440 –520 XUSLBQ6A0520 XUSLBR5A0520 XUSLDMQ6A0520 XUSLDMY5A0520600 XUSLBQ6A0600 – XUSLDMQ6A0600 –680 – XUSLBR5A0680 – XUSLDMY5A0680(1) Other height protected, see catalog:720 XUSLBQ6A0720 – XUSLDMQ6A0720 –"Preventa safety Solutions"880 XUSLBQ6A0880 XUSLBR5A0880 XUSLDMQ6A0880 XUSLDMY5A0880(2) PDM module : Programming and Diagnostic Module, 1040 – XUSLBR5A1040 – XUSLDMY5A1040see following page.1200 – XUSLBR5A1200 – –1400 – XUSLBR5A1400 – XUSLDMY5A14001560 – XUSLBR5A1560 – XUSLDMY5A1560TypeSegments for cascadable light curtainsDetection capacity 14 mm "finger" 30 mm "hand"Transmitter + receiver Height protected (mm) 280 XUSLDSQ6A0280 –320 XUSLDSQ6A0320 –360 – XUSLDSY5A0360440 XUSLDSQ6A0440 –520 XUSLDSQ6A0520 XUSLDSY5A0520600 XUSLDSQ6A0600 –680 – XUSLDSY5A0680720 XUSLDSQ6A0720 –880 XUSLDSQ6A0880 XUSLDSY5A08801040 – XUSLDSY5A10401400 – XUSLDSY5A14001560 – XUSLDSY5A15609/26Other versions: please consult our Customer Care Centre.


Type 4 conforming to IEC 61496-2Light curtain functionsb Auto/Manual/Manual 1 st cycleb Monitoring of external switching devices(EDM: External Devices Monitoring),b Test input (MTS: Monitoring Test Signal),b Alignment aid by LED display of each light beam broken,b LED display of operating modes and alarms,b Coding of the beamsMaximum safety level achieved by the solution PLe/cat4, SILCL3(EN ISO 13849-1, EN/IEC 62061)TypeSingle-beam and multi-beam, infrared transmissionCompact range Transmitter/receiver Transmitter/passive receiverNominal sensing distance (Sn) 0.8…20 ou 70 m (according to config) 0.8…8 mDetection capacityBodyNumber of circuits Safety 2 solid-state PNPAuxiliary (alarm or following) 1 solid-state PNPResponse time (depending on model)16…24 msConnection M12 Connector (1) M12 ConnectorBeam Interval Number– 1 XUSLPZ1AM –300 mm 4 XUSLPZ4A300M –5 XUSLPZ5A300M –6 XUSLPZ6A300M –400 mm 3 XUSLPZ3A400M –500 mm 2 XUSLPZ2A500M XUSLPB2A500M3 XUSLPZ3A500M –600 mm 2 XUSLPZ2A600M XUSLPB2A600M(1) Light curtain with M12 connector output, for terminal block output, replace M from the end of the reference by B. Example : XUSLPZ1AM becomes XUSLPZ1ABCabling accessories12345TypeProlongateursLongueur 5 m 10 m 15 m 30 mPre-wired connector for XUSLB/XUSLDM For receiver <strong>XS</strong>ZBCR05 <strong>XS</strong>ZBCR10 <strong>XS</strong>ZBCR15 <strong>XS</strong>ZBCR30(screened cable)For transmitter <strong>XS</strong>ZBCT05 <strong>XS</strong>ZBCT10 <strong>XS</strong>ZBCT15 <strong>XS</strong>ZBCT30XUSLP For receiver <strong>XS</strong>ZPCR05 <strong>XS</strong>ZPCR10 <strong>XS</strong>ZPCR15 <strong>XS</strong>ZPCR30For transmitter <strong>XS</strong>ZPCT05 <strong>XS</strong>ZPCT10 <strong>XS</strong>ZPCT15 <strong>XS</strong>ZPCT30TypeJumper cables for segments XUS LDS67Cable length 0,3 m 0,5 m 1 m 2 m 2 m 5 m 10 mReference For receiver <strong>XS</strong>ZDCR003 <strong>XS</strong>ZDCR005 <strong>XS</strong>ZDCR010 <strong>XS</strong>ZDCR020 <strong>XS</strong>ZDCR030 <strong>XS</strong>ZDCR050 <strong>XS</strong>ZDCR100For transmitter <strong>XS</strong>ZDCT003 <strong>XS</strong>ZDCT005 <strong>XS</strong>ZDCT010 <strong>XS</strong>ZDCT020 <strong>XS</strong>ZDCT030 <strong>XS</strong>ZDCT050 <strong>XS</strong>ZDCT100Setting-up accessories89Type Programming and Diagnostic Module Laser alignment toolFor light curtains XUSLB / XUSLDM All type XUSLReference XUSLPDM XUSLAT110Other versions: please consult our Customer Care Centre.9/27


PreventaOperator dialogEmergency stopsØ 22 trigger action latching pushbuttons22 211314NC + NOcontact122 21131432 31NC + NO + NCcontactTurn to releaseKey release(key n° 455)Turn to releasePushbuttons Metal PlasticKey release(key n° 455)23Mechanical life (millions of operating cycles) 0.3 0.3Shock / vibration resistance 10 gn / 5 gn 10 gn / 5 gnDegree of protection IP 65 IP 65Rated operational characteristics AC 15, A 600 / DC 13, Q 600 (conforming to EN IEC 60947-5-1)Dimensions Ø x Depth Ø 40 x 82 mm Ø 40 x 104 mm Ø 40 x 81.5 mm Ø 40 x 103 mmContact NC + NO XB4BS8445 XB4BS9445 XB5AS8445 XB5AS94452 NC + 1 NO XB4BS84441 ZB4BS944+ZB4BZ141 ZB5AS844 + ZB5AZ141 ZB5AS944+ZB5AZ1414ISO entry(to EN 50262)Ø 22 trigger action latching pushbutton stations22 211314NC + NOcontact522 2132 31NC + NCcontact67Enclosure22 21131432 31NC + NO + NCcontactTurn to releasePlastic2 x ISO M20 cable entries or n° 13 (Pg 13.5) cable glandKey release (key n° 455)Mechanical life (millions of operating cycles) 0.1 0.1Shock / vibration resistance 10 gn / 5 gn 10 gn / 5 gnDegree of protection IP 65 IP 65Rated operational characteristics AC 15, A 600 / DC 13, Q 600 (conforming to EN IEC 60947-5-1)Dimensions W x D x H 68 x 91 x 68 mm 68 x 113 x 68 mmContact NC + NO XALK178E XALK188ENC + NC XALK178F XALK188F2 NC + 1 NO – XALK188G8Accessories910With legend holderType Étiquettes Padlocking kit Bellows sealsColour Red with white lettering Yellow with black lettering Yellow Red Silicone Black EPDMDimensions 30 x 40 mm (1) Ø 60 mmRéférences Marking: “Emergency stop” ZBY2130 ZBY9130 – – –“Arrêt d'urgence” ZBY2330 ZBY9330 – – –“Not Halt” ZBY2230 ZBY9230 – – –– – ZBZ3605 ZBZ48 ZBZ28(1) circular appearance9/28Other versions: please consult our Customer Care Centre.


Emergency stopsCable (tripwire) operatedISO entry(to EN 50262)12 1112 1114 1322 21NC + NO contactslow breakNC + NC contactslow breakBooted pushbutton reset Key release pushbutton reset (key n° 421)For operating cable length ≤ 15 m Latching, without indicator light with indicator light1 x ISO M20 cable entry (1)Mechanical life (millions of operating cycles) 0.01Shock / vibration resistance50 gn / 10 gnDegree of protection IP 65Rated operational characteristics AC-15, A300 / DC-13, Q300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H201 x 71 x 68 mmOperating cable length≤ 15 mOperating cable anchoring pointTo right or to leftContact 1 NC + NO slow break XY2CH13250H29 XY2CH13450H29 XY2CH132531 NC + NC slow break XY2CH13270H29 XY2CH13470H29 XY2CH13273(1) With entry for n° 13 (Pg 13.5) cable gland, delete H29 from the end of the reference (example: XY2-CH13250H29 becomes XY2-CH13250).123412 1114 13NC + NO contactslow break512 1122 21NC + NC contactslow breakFor operating cable length ≤ 50 mBooted pusbutton reset Key release pushbutton reset (key n° 421)Latching, without indicator light3 x ISO M20 cable entries or n° 13 (Pg 13.5) cable glandMechanical life (millions of operating cycles) 0.01 0.01Shock / vibration resistance 50 gn / 10 gn 50 gn / 10 gnDegree of protection IP 65 IP 65Rated operational characteristics AC-15, A300 / DC-13, Q300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H 229 x 82 x 142 mm 229 x 82 x 142 mmOperating cable length ≤ 50 m ≤ 50 mOperating cable anchoring point To left To right To left To rightContact 1 NC + NO slow break XY2CE2A250 XY2CE1A250 XY2CE2A450 XY2CE1A4501 NC + NC slow break XY2CE2A270 XY2CE1A270 XY2CE2A470 XY2CE1A4702 NC + NO slow break XY2CE2A290 (2) XY2CE1A290 (2) XY2CE2A490 (2) XY2CE1A290 (2)(2) With 24V, 48 V, 130 V pilot lights, BA9S bulb not included, add 6 at the end of the reference. (example : XY2CE1A290 becomes XY2CE1A296).With 230 V pilot lights, BA9S bulb included, add 7 at the end of the reference. (example : XY2CE1A290 becomes XY2CE1A297).678910Other versions: please consult our Customer Care Centre.9/29


PreventaOperator dialogFoot switches - metalSingle pedal switchesISO entry(to EN 50262)1234TypeISO entry(to EN 50262)Foot switches without protective cover2 cable entries for n° 16 (Pg 16) cable gland (1)Trigger mechanism With (positive operating action reqd.) WithoutColour Orange Blue OrangeMechanical life (millions of operating cycles) 15Degree of protection IP 66Shock resistance100 joulesRated operational characteristics AC 15, A 300 / DC 13, Q 300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H104 x 172 x 59 mmContact operation 1 step 1 NC + NO XPER810 XPEM110 XPER1102 NC + NO XPER811 XPEM111 XPER1112 step 2 NC + NO XPER911 XPEM211 XPER211Analogue output 2 NC + NO XPER929 – XPER229(1) For entry for ISO M20 cable gland, also order adaptor DE9RA1620 (sold in lots of 5).5678TypeISO entry(to EN 50262)Foot switches without protective cover2 cable entries for n° 16 (Pg 16) cable gland (1)Trigger mechanism With (positive operating action reqd.) WithoutColour Blue Orange Blue OrangeMechanical life (millions of operating cycles) 15Degree of protection IP 66Shock resistance100 joulesRated operational characteristics AC 15, A 300 / DC 13, Q 300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H 160 x 186 x 152 mmContact operation 1 step 1 NC + NO XPEM510 XPER510 XPEM310 XPER3102 NC + NO XPEM511 XPER511 XPEM311 XPER3111 step latching 1 NC + NO – – XPEM410 XPER4102 step 2 NC + NO XPEM711 XPER711 XPEM611 XPER611Analogue output 2 NC + NO XPEM529 XPER529 XPEM329 –(1) For entry for ISO M20 cable gland, also order adaptor DE9RA1620 (sold in lots of 5).Double pedal switches910TypeFoot switches without protective cover2 cable entries for n° 16 (Pg 16) cable gland (1)Trigger mechanism With (positive operating action reqd.) WithoutColour Blue Orange Blue OrangeMechanical life (millions of operating cycles) 15Degree of protection IP 66Shock resistance100 joulesRated operational characteristics AC 15, A 300 / DC 13, Q 300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H295 x 190 x 155 mmContact operation 1 step 2 x 1 NC + NO XPEM5100D XPER510D XPEM3100D XPER3100D2 x 2 NC + NO XPEM5110D XPER5110D XPEM3110D XPER3110D(1) For entry for ISO M20 cable gland, also order adaptor DE9RA1620 (sold in lots of 5).9/30Other versions: please consult our Customer Care Centre.


Foot switches - plasticSingle pedal switchesISO entry(to EN 50262)1Type Without protective cover With protective cover2 cable entries for ISO M20 cable glandTrigger mechanism Without With (positive operating action reqd.)Colour Yellow Yellow YellowMechanical life (millions of operating cycles) 5Degree of protection IP 55Shock resistance30 joulesRated operational characteristics AC 15, A 300 / DC 13, Q 300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H 160 x 280 x 70 mm 160 x 280 x 162 mm 160 x 280 x 162 mmContact operation 1 step 1 NC + NO XPEY110 XPEY310 XPEY5102 NC + NO – XPEY311 XPEY5112 step 2 NC + NO XPEY211 XPEY611 XPEY71123ISO entry(to EN 50262)4TypeFoot switches without protective cover2 cable entries for ISO M20 cable gland 1 entry (1)Trigger mechanism With (positive operating action reqd.) Without WithoutColour Grey+ Blue Grey BlackMechanical life (millions of operating cycles) 10 2Degree of protection IP 66 IP 43Shock resistance100 joulesRated operational characteristics AC 15, A 300 / DC 13, Q 300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H 160 x 280 x 70 mm 94 x 161 x 54 mmContact operation 1 step 1 NC + NO XPEG810 XPEB110 XPEG110 XPEA1102 NC + NO – XPEB111 XPEG111 XPEA1112 step 2 NC + NO XPEG911 XPEB211 XPEG211 –(1) Cable entry for ISO M16 or n° 9 (Pg 9) cable gland and for ISO M20 or n° 13 (Pg 13.5) cable gland.567ISO entry(to EN 50262)8TypeFoot switches with protective cover2 cable entries for ISO M20 cable glandTrigger mechanism With (positive operating action reqd.) WithoutColour Grey Blue Grey BlueMechanical life (millions of operating cycles) 10Degree of protection IP 66Shock resistance100 joulesRated operational characteristics AC 15, A 300 / DC 13, Q 300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H180 x 280 x 162 mmContact operation 1 step 1 NC + NO XPEG510 XPEB510 XPEG310 XPEB3102 NC + NO XPEG511 XPEB511 XPEG311 XPEB3112 step 2 NC + NO XPEG711 XPEB711 XPEG611 XPEB611910Other versions: please consult our Customer Care Centre.9/31


PreventaOperator dialogControl unitsTwo-hand controlISO entry(to EN 50262)1234567Type0 1 21-25-63-4Contact closed0 1 2Contact open1-25-63-47 8 (XY2-AU2)2 control pushbuttons and 1 mushroom headEmergency stop or Lock out pushbuttonTwo-hand control stations2 cable entries for ISO M20 or n° 13 (Pg 13.5) cable gland, 1 cable entry for n° 21 (Pg 21) cable gland (2)Mechanical life (millions of operating cycles) 1 1Degree of protection IP 65 IP 65Rated operational characteristics AC 15, A 600 / DC 13, Q 600 (conforming to EN IEC 60947-5-1)Dimensions W x D x H455 x 170 x 188.5 mmRed emergency stop (NC + NC slow break) XY2SB71 (1) XY2SB72 (1)Yellow lock out (NC + NO break before make) XY2SB75 XY2SB76(1) To order a two-hand control station with pedestal XY2SB90, add 4 to the end of the reference (example: XY2SB71 becomes XY2SB714).(2) For entry for ISO M25 cable gland, also order adaptor DE9RA2125 + fixing nut DE9EC21 (sold in lots of 5).Contact statesFor fixing accessories, please refer to www.schneider-electric.com.Enabling switch01212346 52 control pushbuttons and 1 mushroom head Emergencystop or Lock out pushbutton, with pre-wired terminal blockTypePlastic gripEntry for Ø 7 to 13 mm cableNumber of contacts 3 3Type of contacts 2 NO + 1 NC 2 NO + 1 NC1 NO auxiliaryDescription 3 positions 3 positions with button for NO contact (auxiliary)Shock / vibration resistance10 gn / 6 gnDegree of protection IP 66 IP 65Rated operational characteristics AC 15, C300 / DC 13, R300 (conforming to EN IEC 60947-5-1)Dimensions W x D x H 46 x 58 x 261 mm 46 x 58 x 269 mmReferences XY2AU1 XY2AU20127812346 589109/32Other versions: please consult our Customer Care Centre.


VarioMotor controlSwitch disconnectorsFront mounting1/L12/T1Type3/L24/T25/L36/T3Door mountingMini-Vario for standard applicationsBackplatemounting inenclosure1Front plate dimensions (mm) 60 x 60 60 x 60Fixing Ø 22.5 mm Ø 22.5 mmDegree of protection IP 20 IP 20Rated operational voltage (Ue) 690 V 690 VThermal current in open air (Ith) 12 A VCDN12 VCCDN1220 A VCDN20 VCCDN20231/L13/L25/L32/T1Type4/T26/T3Door mountingVario for high performance applicationsBackplatemounting inenclosure4Front plate dimensions (mm) 60 x 60 60 x 60 90 x 90 60 x 60 60 x 60 90 x 90Fixing Ø 22.5 mm 4 screws 4 screws Ø 22.5 mm 4 screws 4 screwsDegree of protection IP 20 IP 20 IP 20 IP 20 IP 20 IP 20Rated operational voltage (Ue) 690 V 690 V 690 V 690 V 690 V 690 VThermal current in open air (Ith) 12 A VCD02 VCF02 – VCCD02 VCCF02 –20 A VCD01 VCF01 – VCCD01 VCCF01 –25 A VCD0 VCF0 – VCCD0 VCCF0 –32 A VCD1 VCF1 – VCCD1 VCCF1 –40 A VCD2 VCF2 – VCCD2 VCCF2 –63 A – VCF3 – – VCCF3 –80 A – VCF4 – – VCCF4 –125 A – – VCF5 – – VCCF5175 A – – VCF6 – – VCCF61/L13/L25/L3Enclosed5672/T14/T26/T3Type Mini-Vario Vario8Front plate dimensions (mm) 60 x 60 60 x 60 90 x 90Dimensions W x D x H 82.5 x 106 x 131 mm 90 x 131 x 146 mm 241 x 191 x 291 mmDegree of protection IP 55 IP 65 IP 65Rated operational voltage (Ue) 690 V 690 V 690 VThermal current in enclosure (Ithe) 10 A VCFN12GE VCF02GE –16 A VCFN20GE VCF01GE –20 A VCFN25GE VCF0GE –25 A VCFN32GE VCF1GE –32 A VCFN40GE VCF2GE –50 A – VCF3GE (1) –63 A – VCF4GE (1) –100 A – – VCF5GEN140 A – – VCF6GEN(1) Dimensions W x D x H: 150 x 152 x 170 mm.910Other versions: please consult our Customer Care Centre.9/33


TeSysMotor controlMotor startersEnclosed thermal-magnetic motor circuit-breakers1/L13/L25/L31T1T2T3Complete circuit-breaker: circuit-breaker+ enclosure + safety device.Ex.: GV2ME01 + GV2MC02 + GV2K04.TypeThermal-magnetic motor circuit-breakers234Motor power kW (on 400 V) – 0.06 0.09 0.12…0.18 0.25…0.37Setting range A 0.1…0.16 0.16…0.25 0.25…0.40 0.40…0.63 0.63…1Current Id ± 20% A 1.5 2.4 5 8 13Current Ithe (in enclosure) A 0.16 0.25 0.40 0.63 1Reference GV2ME01 GV2ME02 GV2ME03 GV2ME04 GV2ME05Motor power kW (on 400 V) 0.37…0.55 0.75 1.1…1.5 2.2 3…4Setting range A 1…1.6 1.6…2.5 2.5…4 4…6.3 6…10Current Id ± 20% A 22.5 33.5 51 78 138Current Ithe (in enclosure) A 1.6 2.5 4 6.3 9Reference GV2ME06 GV2ME07 GV2ME08 GV2ME10 GV2ME14Motor power kW (on 400 V) 5.5 7.5 9…11 11 15Setting range A 9…14 13…18 17…23 20…25 24…32Current Id ± 20% A 170 223 327 327 416Current Ithe (in enclosure) A 13 17 21 23 24Reference GV2ME16 GV2ME20 GV2ME21 GV2ME22 GV2ME325Enclosure6TypeEmpty enclosure7Mounting Surface mounting Flush mountingDegree of protection IP 55 IP 55 (front face)Dimensions W x D x H (1) 93 x 145.5 x 147 mm 93 x 55 x 126 mmReferences GV2MC02 GV2MP02(1) Dimensions with safety device GV2K04 fitted.8Safety device9TypeSafety devices10With red mushroom head Turn to release Turn to release Key releasePadlockable in “Off” position (key n° 455)References GV2K04 GV2K031 GV2K0219/34Other versions: please consult our Customer Care Centre.


1Type Non reversing ReversingDegree of protection IP 657 IP 657 IP 657Standard motor power ratings (kW), category AC3 Ith setting Basic reference, to be completed by code indicating voltage (1)220/230 V 400/415 V 440 V range (A)– 0.06 0.06 0.16…0.25 LG1K065pp02 LG7K06pp02 LG8K06pp020.06 0.09 0.12 0.25…0.40 LG1K065pp03 LG7K06pp03 LG8K06pp03– 0.18 0.18 0.40…0.63 LG1K065pp04 LG7K06pp04 LG8K06pp040.12 0.25 0.25 0.63…1 LG1K065pp05 LG7K06pp05 LG8K06pp050.25 0.55 0.55 1…1.6 LG1K065pp06 LG7K06pp06 LG8K06pp060.37 0.75 1.1 1.6…2.5 LG1K065pp07 LG7K06pp07 LG8K06pp070.75 1.5 1.5 2.5…4 LG1K065pp08 LG7K06pp08 LG8K06pp081.1 2.2 3 4…6.3 LG1K065pp10 LG7K06pp10 LG8K06pp101.5 4 4 6…10 LG1K095pp14 LG7K09pp14 LG8K09pp143 5.5 5.5 9…14 LG1D122pp16 LG7D12pp16 LG8K12pp164 7.5 9 13…18 LG1D182pp20 LG7D18pp20 –4 9 9 17…23 LG1D182pp21 LG7D18pp21 –2345With integral control transformer, 400/24 VType Non reversing ReversingWith integral control transformer, 400/24 V6Degree of protection IP 657 IP 657Standard motor power ratings (kW), category AC3 Ith setting Basic references380/400 V range (A) (The code Q7 (380/400 V) designates the power supply voltage to which the starter will be connected)0.06 0.16…0.25 LJ7K06Q702 LJ8K06Q7020.09 0.25…0.40 LJ7K06Q703 LJ8K06Q7030.18 0.40…0.63 LJ7K06Q704 LJ8K06Q7040.25 0.63…1 LJ7K06Q705 LJ8K06Q7050.55 1…1.6 LJ7K06Q706 LJ8K06Q7060.75 1.6…2.5 LJ7K06Q707 LJ8K06Q7071.5 2.5…4 LJ7K06Q708 LJ8K06Q7082.2 4…6.3 LJ7K06Q710 LJ8K06Q7104 6…10 LJ7K09Q714 LJ8K09Q714789Control circuit voltages availableVolts 50/60 Hz 24 V 230 V 400 V 415 V(1) Voltage code B7 P7 V7 N7The control circuit must be cabled by the user.10Other versions: please consult our Customer Care Centre.9/35


1A reference for installations in ATEX Dustexplosive atmospheres.What is an explosive atmosphere accordingto the Directive?It is the mixing with air, in atmospheric conditions, of flammablesubstances in the form of gas, vapour, mist or dust which, inthe event of combustion, spreads throughout the non burning mix.234A selection of certifiedproducts, conforming tothe European DirectiveATEX94/9/EC, to ensuremaximum safety for yourinstallations in a zone wherethe risk of explosion or fire ishigh.5678910The products inthis catalogare certified by aEuropean UnionCommissionnotified body.ZONE 22ZONE 20ZONE 21Implementation of European DirectivesDirective 99/92/ECThis requires that a risk analysis be performed for all industrial processes.If there is any risk of an explosion:p the zones are defined and physically identified,p the installation is classified by governing bodies.Directive 94/9/ECThis requires certification of the products in accordance with the classification of the zones ofuseDust zonesp Zone 20: area where an explosive atmosphere exists in the form of combustible clouds of dustin the air, either permanently, for long periods or frequently.p Zone 21: area where an explosive atmosphere exists in the form of combustible clouds of dust inthe air during normal operation occasionally.p Zone 22: area where an explosive atmosphere in the form of combustible clouds of dustin the air is unlikely to occur during normal operation but, if it does occur, it is only for a shortperiod.


Explosive atmospheresThis document is a selection ofthe top selling products.1DetectionInductive proximity sensors <strong>OsiSense</strong> <strong>XS</strong> ................................................... 10/2 to 10/4Discrete ................................................................................................................................. 10/2Rotation monitoring ............................................................................................................... 10/3Namur .................................................................................................................................... 10/4Intrinsically safe enclosures ......................................................................................... 10/5Processing module, NY3Limit switches <strong>OsiSense</strong> XC .............................................................................. 10/6 to 10/9Miniature, XCMCompact, XCKDClassic, XCKMApplications: Hoisting, Handling and ConveyingPressure and vacuum switches <strong>OsiSense</strong> XM ....................................10/10 and 10/11Adjustable differential, XMLBOperator dialogControl and signalling unitsPushbuttons and mushroom heads Ø 22, Harmony XB4 ................................................. 10/12Selector switches and key switches Ø 22, Harmony XB4 ................................................. 10/13Illuminated pushbuttons and pilot lights Ø 22, Harmony XB4 ........................................... 10/14Control stations, Harmony XAW ........................................................................................ 10/15Machine safetyAutomationHuman/Machine InterfaceSmall Panels and Advanced Panels, Magelis XBT N, R, RT, GT ........................ 10/16 to 10/19Tripwire operated Emergency stops, Preventa XY2 .......................................................... 10/20Foot switches, Preventa XPE ............................................................................................ 10/20Safety switches, Preventa XCS ......................................................................................... 10/21Weighing system, Modicon Premium ............................................................................... 10/22I/O modules, Modicon Quantum ....................................................................................... 10/22234567891010/1


<strong>OsiSense</strong> <strong>XS</strong>Inductive proximity sensorsDiscrete, metal case1Sensor typeM12 M18 M303-wire DC PNP, flush mountable in metal234Conformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0022X / D-Ex tD A21 IP68 T90°CNominal sensing distance Sn 4 mm 8 mm 15 mmOperating zone 0...3.2 mm 0...6.4 mm 0...12 mmTemperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP68ConnectionPre-cabled, PvR, L = 10 mDimensions M12 x 50 mm M18 x 60 mm M30 x 60 mmSupply voltage (including ripple)10...58 VDCMaximum switching capacity200 mAOverload and short-circuit protectionYesLED output state indicatorYesVoltage drop, closed state, at I nominal≤ 2 VSwitching frequency 2500 Hz 1000 Hz 500 HzReferences NO function <strong>XS</strong>612B1PAL10EX <strong>XS</strong>618B1PAL10EX <strong>XS</strong>630B1PAL10EXNC function <strong>XS</strong>612B1PBL10EX <strong>XS</strong>618B1PBL10EX <strong>XS</strong>630B1PBL10EX5Analog, metal case67Sensor typeM12 M18 M30Analogue, 2-wire AC/DC, flush mountable in metal89Conformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0022X / D-Ex tD A21 IP67 T90°CNominal sensing distance Sn 2 mm 5 mm 10 mmOperating zone 0.2...2 mm 0.5…5 mm 1...10 mmTemperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP67ConnectionPre-cabled, PvR, L = 2 mDimensions M12 x 50 mm M18 x 60 mm M30 x 60 mmSupply voltage (including ripple)10…38 VAC/DCLinearity error 10%Operating frequency 1500 Hz 500 Hz 300 HzReferences 4…20 mA output <strong>XS</strong>1M12AB120EX <strong>XS</strong>1M18AB120EX <strong>XS</strong>1M30AB120EX10Other characteristics: please refer to the “Detection for <strong>OsiSense</strong> automation solutions” catalog10/2Other versions: please consult our Customer Care Centre.


Inductive Proximity sensorsRotation monitoring, metal case1Sensor typeM303-wire DC PNP, flush mountable in metalConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0022X / D-Ex tD A21 IP67 T90°CNominal sensing distance Sn10 mmOperating zone0…8 mmTemperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP67ConnectionPre-cabled, PvR, L = 2 mDimensionsM30 x 81 mmSupply voltage (including ripple)10...58 VDCMaximum switching capacity200 mAOverload and short-circuit protectionYesLED output state indicatorYesVoltage drop, closed state, at I nominal≤ 2 VVersion Slow FastMaximum speed of passing object 6000 impulses/minute 48,000 impulses/minuteAdjustable frequency range 6…150 impulses/minute 120…3000 impulses/minuteReferences NC function <strong>XS</strong>AV11373EX <strong>XS</strong>AV12373EX2345678910Other versions: please consult our Customer Care Centre.10/3


<strong>OsiSense</strong> <strong>XS</strong>Namur inductive sensorsMetal or plastic case1234M5 M8 M12 M18 M30Sensor type2-wire DC, flush mountable in metalCase typeMetalPlasticConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, EN 50020, EN 50284, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 20 (to be used in conjunction with intrinsically safe enclosures, see page 5)EC type examination certificate number / marking INERIS 04ATEX0016X / D-Ex iaD 20 IP66/67 T85°CNominal sensing distance Sn 0.8 mm 1.5 mm 2 mm 5 mm 10 mmOperating zone 0…0.6 mm 0…0.8 mm 0…1.2 mm 0…1.6 mm 0…4 mm 0…8 mmTemperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP67ConnectionPre-cabled, PvR, L = 2 mDimensions M5 x 30 mm M8 x 26.5 mm M12 x 38.5 mm M18 x 41 mm M30 x 43.5 mmSupply voltage (including ripple)7…12 VDCMaximum switching capacity≤ 1 mAOverload and short-circuit protectionYesResidual current, open state≥ 3 mASwitching frequency 1500 Hz 1000 Hz 800 Hz 500 Hz 300 HzReferences NC function <strong>XS</strong>MN08122EX <strong>XS</strong>AN01122EX <strong>XS</strong>PN01122EX <strong>XS</strong>PN02122EX <strong>XS</strong>PN05122EX <strong>XS</strong>PN10122EX5Plastic case678910M12 M18 M30 Forme DSensor type2-wire DC, non flush mountable in metalCase typePlasticConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, EN 50020, EN 50284, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 20EC type examination certificate number / marking INERIS 04ATEX0016X / D-Ex iaD 20 IP66/67 T85°CNominal sensing distance Sn 4 mm 8 mm 15 mm 40 mmOperating zone 0…3.2 mm 0…6.4 mm 0…12 mm 0…32 mmTemperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP67ConnectionPre-cabled, PvR, L = 2 mDimensions M12 x 38.5 mm M18 x 41 mm M30 x 43.5 mm 100 x 80 x 40 mmSupply voltage (including ripple)7…12 VDCMaximum switching capacity≤ 1 mAOverload and short-circuit protectionYesLED output state indicatorYesResidual current, open state≥ 3 mASwitching frequency 400 Hz 300 Hz 200 Hz 25 HzReferences NC function <strong>XS</strong>PN04122EX <strong>XS</strong>PN08122EX <strong>XS</strong>PN15122EX <strong>XS</strong>DN401229EX(1) Flush mountable in metalOther characteristics: please refer to the “Detection for <strong>OsiSense</strong> automation solutions” catalog10/4Other versions: please consult our Customer Care Centre.


Intrinsically safe moduleProcessing module1Module typeDiscreteInputsRelay inputs/outputsConformityDirective ATEX 94/9/EC, EN 50014, EN 50020, EN 50021-1&2, EN 50082-1&2Zone D (dust) Mounted outside zone (to be used in conjunction with products for zone 20, 21 or 22)EC type examination certificate number / marking LCIE 00ATEX6034X / G/D-[EEx ia] IICZone 20 Number of input channels 2 4 2 2Number of output channels – 1 1Type of output channel, – Low consumption solenoid valve, < 7 mA High consumption solenoid valve, < 40 mAload excitation – with hysteresis – with hysteresisOutside zone Number of recopying channels 2 4 2 2Switching voltage5…230 VAC; 5…24 VDCSwitching current10 mA…0.5 A (AC); 10 mA…0.5 A, L/R 48 ms (DC)Temperature range – 20...+ 60°CConnectionRemovable screw terminal blocksMountingOn 35 mm DIN railDimensions, W x D x H29.5 x 120 x 90 mmSupply voltage (including ripple)24 VDC (0.95…1.1 Un)Consumption5 WReferences NY320N2RB1 NY340N4RB1 NY321L2RB1 NY321L1RB1 NY321H2RB1 NY321H1RB123456Module typeDiscreteLoad excitation outputsConformityDirective ATEX 94/9/EC, EN 50014, EN 50020, EN 50021-1&2, EN 50082-1&2Zone D (dust) Mounted outside zone (to be used in conjunction with products for zone 20, 21 or 22)EC type examination certificate number / marking LCIE 00ATEX6034X / G/D-[EEx ia] IICZone 20 Number of load excitation channels 2 4Maximum current < 7 mA < 40 mA < 7 mA < 40 mAOutside zone Control voltage 24 VDC ± 10%Control currentState 1 = 6.5 < I < 9 mA and 21.6 < U < 26.4 V; State 0 = I ≤ 0.4 mA and U ≤ 1.2 VTemperature range – 20...+ 60°CConnectionRemovable screw terminal blocksMountingOn 35 mm DIN railDimensions, W x D x H29.5 x 120 x 90 mmSupply voltage (including ripple)24 VDC (0.95…1.1 Un)Consumption5 WReferences NY302L0NB1 NY302H0NB1 NY304L0NB1 NY304H0NB178910Other versions: please consult our Customer Care Centre.10/5


<strong>OsiSense</strong> XCLimit switchesMiniature, fixing by the body12345Limit switch typeXCMD metal, pre-cabledWith head for movementLinear (plunger)Conformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0014X / D-Ex tD A21 IP66/67 T85°CType of operator Metal end Metal end Steel roller Retractableplunger plunger with plunger steel rollerelastomer bootlever plungerMechanical durability (millions of operating cycles) 10Actuation speed0.5 m/sSwitches conforming to standard IEC 947-5-1 section 3Temperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP66 and IP67Rated operational characteristics AC15; C300 (Ue = 240 V, Ie = 0.75 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)Short-circuit protectionBy 6 A cartridge fuse type gG (gl)Cable entryPre-cabled, adjustable direction, length = 5 mFixing centres20 mmBody dimensions, W x D x H30 x 16 x 50 mmReferences 2NC+2NO snap action XCMD4110L5EX XCMD4111L5EX XCMD4102L5EX XCMD4124L5EXCompact, fixing by the body678910Limit switch type XCKD metal conforming to standard EN 500047With head for movementLinear (plunger)Conformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0014X /D-Ex tD A21 IP66/67 T85°CType of operator Metal end Metal end Steel roller Thermoplastic roller Thermoplastic rollerplunger plunger with plunger lever plunger, horiz. lever plunger, vert.elastomer boot actuation in 1 direct. actuation in 1 direct.Mechanical durability (millions of operating cycles) 15 10 15Actuation speed 0.5 m/s 1 m/sSwitches conforming to standard IEC 947-5-1 section 3Temperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP66 and IP67Rated operational characteristics AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)Short-circuit protectionBy 6 A cartridge fuse type gG (gl)Cable entry1 entry fitted with ISO M16 cable glandFixing centres20 mmBody dimensions, W x D x H31 x 30 x 65 mmReferences 2NC+1NO snap action XCKD3910P16EX XCKD3911P16EX XCKD3902P16EX XCKD3921P16EX XCKD3927P16EXOther characteristics: please refer to the “Detection for <strong>OsiSense</strong> automation solutions” catalog10/6Other versions: please consult our Customer Care Centre.


Miniature, fixing by the head1XCMD metal, pre-cabledRotary (lever)Linear (plunger)Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-121 - 22INERIS 04ATEX0014X / D-Ex tD A21 IP66/67 T85°CSteel roller Thermoplastic roller Roller lever Variable length M12 with metal M16 with metal M12 with steellever lever with ball bearing thermoplastic end plunger end plunger with roller plungermounted roller roller lever elastomer boot101.5 m/s 0.5 m/s 0.1 m/s23– 20...+ 60°CIP66 and IP67AC15; C300 (Ue = 240 V, Ie = 0.75 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)By 6 A cartridge fuse type gG (gl)Pre-cabled, adjustable direction, length = 5 m20 mm M12 x 1 M16 x 1 M12 x 130 x 16 x 50 mmXCMD4116L5EX XCMD4115L5EX XCMD4117L5EX XCMD4145L5EX XCMD41F0L5EX XCMD41G1L5EX XCMD41F2L5EXCompact, fixing bythe head456XCKD metal conforming to standard EN 500047Linear (plunger) Rotary (lever) Multi-directional Linear (plunger)Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-121 - 22INERIS 04ATEX0014X / D-Ex tD A21 IP66/67 T85°CThermoplastic roller Thermoplastic Thermoplastic Variable length Variable length “Cat’s whisker” M18 with metal M18 with steellever plunger, horiz. or roller lever roller lever, thermoplastic thermoplastic end plunger roller plungervert. actuation in 1 dir. Ø 50 mm roller lever roller lever, Ø 50 mm15 10 5 101 m/s 1.5 m/s 1 m/s 0.5 m/s–– 20...+ 60°CIP66 and IP67AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)By 6 A cartridge fuse type gG (gl)1 entry fitted with ISO M16 cable gland20 mm M18 x 130 x 16 x 50 mmXCKD3928P16EX XCKD3918P16EX XCKD3939P16EX XCKD3945P16EX XCKD3949P16EX XCKD3906P16EX XCKD39H0P16EX XCKD39H2P16EX78910Other versions: please consult our Customer Care Centre.10/7


<strong>OsiSense</strong> XCLimit switchesClassic, fixing by the body12345Limit switch typeXCKM metal, 3 cable entriesWith head for movement Linear (plunger) Rotary (lever) Multi-directionalConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0014X / D-Ex tD A21 IP66/67 T85°CType of operator Metal end Steel roller Thermoplastic roller Thermoplastic “Cat’s whisker”plunger plunger lever plunger, horiz. roller leveractuation in 1 direct.Mechanical durability (millions of operating cycles) 20 10Actuation speed 0.5 m/s 1.5 m/s 0.5 m/sSwitches conforming to standard IEC 947-5-1 section 3 –Temperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP66Rated operational characteristics AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)Short-circuit protectionBy 6 A cartridge fuse type gG (gl)Cable entry 3 tapped entries for ISO M20 cable gland (1)Fixing centres41 mmBody dimensions, W x D x H63 x 30 x 64 mmReferences 2NC+1NO snap action XCKM3910H29EX XCKM3902H29EX XCKM3921H29EX XCKM3915H29EX XCKM3906H29EX(1) 2 entries fitted with blanking plugs, 1 entry fitted with ISO M20 cable glandApplication - hoisting, handling, conveying678910Limit switch typeXCKMR metal, 3 cable entriesWith head for movementRotary (lever)Conformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0014X / D-Ex tD A21 IP66/67 T85°CType of operator Metal rod levers, ”crossed” Metal rod levers, ”crossed”reversed headMechanical durability (millions of operating cycles) 2Actuation speed1.5 m/sSwitches conforming to standard IEC 947-5-1 section 3Temperature range – 20...+ 60°CDegree of protection (conforming to IEC 60529)IP66Rated operational characteristics AC15; A300 (Ue = 240 V, Ie = 3 A)/DC13; Q300 (Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Cable entry 3 tapped entries for ISO M20 cable gland (1)Fixing centres61.5 mmBody dimensions, W x D x H118 x 59 x 77 mm2 (NC+NC) staggered, slow break contacts XCKMR54D1H29EX XCKMR54D2H29EX2 (NC+NO) snap action contacts, both actuated in each direction –2 (NC+NO) snap action contacts, 1 actuated in each direction –2 CO staggered snap action contacts –(1) 2 entries fitted with blanking plugs, 1 entry fitted with ISO M20 cable glandOther characteristics: please refer to the “Detection for <strong>OsiSense</strong> automation solutions” catalog.10/8Other versions: please consult our Customer Care Centre.


1XCKJ metal, fixed body, conforming to standard EN 50041Linear (plunger)Rotary (lever)Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-121 - 22INERIS 04ATEX0014X / D-Ex tD A21 IP66/67 T85°CMetal end Steel roller Steel roller Thermoplastic roller Variable length Polyamide rodplunger plunger lever lever thermoplastic lever, Ø 6 x 200 mmroller lever30 25 30 200.5 m/s 1 m/s 1.5 m/s–– 20...+ 60°CIP66AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)By 6 A cartridge fuse type gG (gl)1 entry fitted with ISO M20 cable gland30 x 60 mm40 x 44 x 77 mmXCKJ3961H29EX XCKJ3967H29EX XCKJ390513H29EX XCKJ390511H29EX XCKJ390541H29EX XCKJ390559H29EX23456XCR metalRotary (lever)Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Conveyor belt shift monitoring switches21 - 22INERIS 04ATEX0024X / D-Ex tD A21 IP65 T85°CSquare (6 mm) Thermoplastic roller Large thermoplastic roller Metal rod levers, Galvanised steel Stainless steelrod lever, spring (Ø 30 mm) lever, spring (Ø 50 mm) lever, spring ”crossed”, stay put operating lever operating leverreturn to off position return to off position return to off position10 0.31.5 m/s–– 20...+ 60°CIP65AC15; A300 (Ue = 240 V, Ie = 3 A)/DC13; Q300 (Ue = 250 V, Ie = 0.27 A)By 10 A cartridge fuse type gG (gl)1 entry fitted with n° 13 cable gland85 x 75 mm85 x 75 x 95 mm–XCRA111EX XCRA121EX XCRA151EX XCRE181EX (2) –XCRB111EX XCRB121EX XCRB151EX XCRF171EX (3) –– XCRT115EX XCRT215EX(2) “Crossed” rods (3) “T” rods78910Other versions: please consult our Customer Care Centre.10/9


<strong>OsiSense</strong> XMElectromechanical pressure & vacuum switchesAdjustable differential, regulation between 2 thresholds1234TypeVacuum switches and vacu-pressure switches with setting scaleSize - 1 bar - 0.2 bar 5 barConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0058 / D-Ex tD A21 IP66 T85°CFluid connection1/4” BSP femaleElectrical connectionScrew terminals, 1 entry fitted with ISO M20 cable glandTemperature range – 20...+ 60°CDegree of protectionIP66Rated operational characteristics AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Setting range of upper limit (PH) –0.14…–1 bar –0.02…–0.2 bar –0.5…5 barBody dimensions, W x D x H 55 x 77.5 x 158 mm 150 x 155.5 x 145 mm 113 x 35 x 75 mmFluids controlled Oil, water, air, up to +70°C Oil, air, up to +160°C Oil, water, air, up to +70°CPossible differential Min. at low setting 0.13 bar 0.018 bar 0.5 bar(subtract from PH Min. at high setting 0.13 bar 0.018 bar 0.5 barto give PB) (1) Max. at high setting 0.8 bar 0.18 bar 6 bar1 CO single pole, snap action contact XMLBM02V2S12EX XMLBM03R2S12EX XMLBM05A2S12EX(1) For XMLBM02V2S12EX and XMLBM03R2S12EX vacuum switches add to PB to give PH5678910TypePressure switches with setting scaleSize 10 bar 20 bar 35 barConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0058 / D-Ex tD A21 IP66 T85°CFluid connection1/4” BSP femaleElectrical connectionScrew terminals, 1 entry fitted with ISO M20 cable glandTemperature range – 20...+ 60°CDegree of protectionIP66Rated operational characteristics AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Setting range of upper limit (PH) 0.7…10 bar 1.3…20 bar 3.5…35 barBody dimensions, W x D x H35 x 75 x 113 mmFluids controlledOil, water, air, up to +70°CPossible differential Min. at low setting 0.57 bar 1 bar 1.7 bar(subtract from PH Min. at high setting 0.85 bar 1.6 bar 2.55 barto give PB) Max. at high setting 7.5 bar 11 bar 20 bar1 CO single pole, snap action contact XMLB010A2S12EX XMLB020A2S12EX XMLB035A2S12EXOther characteristics: please refer to the “Detection for <strong>OsiSense</strong> automation solutions” catalog.10/10Other versions: please consult our Customer Care Centre.


1Pressure switches with setting scale0.05 bar 0.35 bar 1 bar 2.5 bar 4 barDirective ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-121 - 22INERIS 04ATEX0058 / D-Ex tD A21 IP66 T85°C1/4” BSP femaleScrew terminals, 1 entry fitted with ISO M20 cable gland– 20...+ 60°CIP66AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)By 10 A cartridge fuse type gG (gl)0.026…0.05 bar 0.045…0.35 bar 0.05…1 bar 0.3…2.5 bar 0.25…4 bar200 x 204 x 145 mm 110 x 110 x 162 mm 55 x 77.5 x 158 mm 55 x 77.5 x 158 mmOil, air, up to +160°COil, water, air, up to +70°C0.0014 bar 0.042 bar 0.04 bar 0.16 bar 0.2 bar0.004 bar 0.05 bar 0.06 bar 0.21 bar 0.25 bar0.04 bar 0.3 bar 0.75 bar 1.75 bar 2.4 barXMLBL05R2S12EX XMLBL35R2S12EX XMLB001R2S12EX XMLB002A2S12EX XMLB004A2S12EX23456Pressure switches with setting scale70 bar 160 bar 300 bar 500 barDirective ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-121 - 22INERIS 04ATEX0058 / D-Ex tD A21 IP66 T85°C1/4” BSP femaleScrew terminals, 1 entry fitted with ISO M20 cable gland– 20...+ 60°CIP66AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)By 10 A cartridge fuse type gG (gl)7…70 bar 10…160 bar 22…300 bar 30…500 bar35 x 75 x 113 mmOil, up to +160°C4.7 bar 9.3 bar 19.4 bar 23 bar8.8 bar 20.8 bar 37 bar 52.6 bar50 bar 100 bar 200 bar 300 barXMLB070D2S12EX XMLB160D2S12EX XMLB300D2S12EX XMLB500D2S12EX78910Other versions: please consult our Customer Care Centre.10/11


HarmonyPushbuttons and mushroom headsContact functions123456TypeØ 22 pushbuttons with metal bezelConformity Directive ATEX D 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX9004U / D-Ex tD A21 IP65/66Mechanical durability (millions of operating cycles) 5Temperature range – 20...+ 60°CDegree of protectionIP65 and IP66Mounting Panel cut-out Ø 22.5 mm (22.4 0recommended )Mounting centres30 x 40 mmDepth below head43 mmConnectionScrew clamp terminalsRated operational characteristicsAC15; A600 (Ue = 600 V, Ie = 1.2 A or Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 ADC13; Q600 (Ue = 600 V, Ie = 0.1 A or Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Pushbutton typeFlush with transparent silicone bootContact NO NC NOColour of push p white p black p green p red p yellow p blueReferences Insertion of legend not possible – XB4BP21EX XB4BP31EX XB4BP42EX XB4BP51EX XB4BP61EXInsertion of legend possible XB4BP181EX – XB4BP381EX XB4BP482EX XB4BP581EX XB4BP681EXPushbutton typeFlush with coloured silicone bootContact NO NC NOColour of silicone boot p white p black p green p red p yellow p blueReferences XB4BPS11EX XB4BPS21EX XB4BPS31EX XB4BPS42EX XB4BPS51EX XB4BS61EXØ 40 mushroom head pushbutton typeSpring returnContact NO NC NOColour of push p black p green p red p yellow p blueReferences XB4BC21EX XB4BC31EX XB4BC42EX XB4BC51EX XB4BC61EX7TypeØ 40 mushroom head Emergency stop pushbuttons8910Conformity Directive ATEX D 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1, IEC/EN 60947-5-5Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX9004U / D-Ex tD A21 IP65/66Mechanical durability (millions of operating cycles) 0.3Temperature range – 20...+ 60°CDegree of protectionIP65Mounting Panel cut-out Ø 22.5 mm (22.4 0recommended )Mounting centres30 x 40 mmDepth below head43 mmConnectionScrew clamp terminalsRated operational characteristicsAC15; A600 (Ue = 600 V, Ie = 1.2 A or Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 ADC13; Q600 (Ue = 600 V, Ie = 0.1 A or Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Ø 40 latching mushroom head pushbutton type Push-pull with trigger action Key release ( n° 455) Turn to releaseContact(s) NC+NO NC NCColour of push p red p red p redReferences XB4BT845EX XB4BS142EX XB4BS542EXOther characteristics: please refer to the “Human-Machine Interface components” catalog10/12Other versions: please consult our Customer Care Centre.


Selector switches and key switchesContact functions1TypeØ 22 selector switches and key switches with metal bezelConformity Directive ATEX D 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX9004U / D-Ex tD A21 IP65/66Mechanical durability (millions of operating cycles) 3Temperature range – 20...+ 60°CDegree of protectionIP65Mounting Panel cut-out Ø 22.5 mm (22.4 0recommended )Mounting centres30 x 40 mmDepth below head43 mmConnectionScrew clamp terminalsRated operational characteristicsAC15; A600 (Ue = 600 V, Ie = 1.2 A or Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 ADC13; Q600 (Ue = 600 V, Ie = 0.1 A or Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Selector switch typeStandard handleContacts NC+NO NO+NOColour p black p blackReferences 2 position stay put XB4BD25EX –3 position stay put – XB4BD33EX3 position spring return to centre – XB4BD53E<strong>XS</strong>elector switch typeLong handleContact(s) NO NO+NOColour p black p blackReferences 2 position stay put XB4BJ21EX –3 position stay put – XB4BJ33EX3 position spring return to centre – XB4BJ53EXKey switch type Key n° 455Contact(s) NO NO+NOColour p black p blackReferences 2 position stay put, key withdrawal in LH position XB4BG21EX –2 position stay put, key withdrawal in both positions XB4BG41EX –2 position spring return, key withdrawal in LH position XB4BG61EX –3 position stay put, key withdrawal in centre position – XB4BG33EX3 position stay put, key withdrawal in all 3 positions – XB4BG03EX2345678910Other characteristics: please refer to the “Human-Machine Interface components” catalogOther versions: please consult our Customer Care Centre.10/13


HarmonyIlluminated pushbuttons and pilot lightsContact and light functions (integral LED)12345TypeØ 22 illuminated pushbuttons with metal bezelConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX9004U / D-Ex tD A21 IP65/66Mechanical durability (millions of operating cycles) 5Service life100,000 hours at ambient temperatureTemperature range – 20...+ 60°CDegree of protectionIP65Mounting Panel cut-out Ø 22.5 mm (22.4 0recommended )Mounting centres30 x 40 mmDepth below head43 mmConnectionScrew clamp terminalsRated operational characteristicsAC15; A600 (Ue = 600 V, Ie = 1.2 A or Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 ADC13; Q600 (Ue = 600 V, Ie = 0.1 A or Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Light sourceIntegral LEDIlluminated pushbutton type, with integral LEDFlush with transparent silicone bootContact NO NC NOColour of push p white p green p red p yellow p blueReferences LED voltage 24 VAC/DC XB4BP183B5EX XB4BP383B5EX XB4BP483B5EX XB4BP583B5EX XB4BP683B5EX110…120 VAC XB4BP183G5EX XB4BP383G5EX XB4BP483G5EX XB4BP583G5EX XB4BP683G5EX240 VAC XB4BP183M5EX XB4BP383M5EX XB4BP483M5EX XB4BP583M5EX XB4BP683M5EX24…120 VAC/DC XB4BP183BG5EX XB4BP383BG5EX XB4BP483BG5EX XB4BP583BG5EX XB4BP683BG5EX678910TypeØ 22 pilot lights with metal bezelConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX9004U / D-Ex tD A21 IP65/66Service life100,000 hours at ambient temperatureTemperature range – 20...+ 60°CDegree of protectionIP65Mounting Panel cut-out Ø 22.5 mm (22.4 0recommended )Mounting centres30 x 40 mmDepth below head43 mmConnectionScrew clamp terminalsRated operational characteristicsAC15; A600 (Ue = 600 V, Ie = 1.2 A or Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 ADC13; Q600 (Ue = 600 V, Ie = 0.1 A or Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Light sourceIntegral LEDPilot light typePilot lights with integral LED, plain lensColour of LED p white p green p red p yellow p blueReferences LED voltage 24 VAC/DC XB4BVB1EX XB4BVB3EX XB4BVB4EX XB4BVB5EX XB4BVB6EX110…120 VAC XB4BVG1EX XB4BVG3EX XB4BVG4EX XB4BVG5EX XB4BVG6EX240 VAC XB4BVM1EX XB4BVM3EX XB4BVM4EX XB4BVM5EX XB4BVM6EX24…120 VAC/DC XB4BVBG1EX XB4BVBG3EX XB4BVBG4EX XB4BVBG5EX XB4BVBG6EXOther characteristics: please refer to the “Human-Machine Interface components” catalog10/14Other versions: please consult our Customer Care Centre.


Control stationsComplete stations, metal or plastic1TypeComplete control stationsType of operatorsØ 22 flush pushbuttonsConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0023/ D-Ex tD A21 IP65 T85°CTemperature range – 20...+ 60°CDegree of protectionIP65Connection1 entry fitted with ISO M20 cable glandRated operational characteristics of contact blocksAC15; A600 (Ue = 600 V, Ie = 1.2 A or Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 ADC13; Q600 (Ue = 600 V, Ie = 0.1 A or Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Function 1 function, Start or Stop 2 functions, Start - Stop 3 functionsComposition 1 spring return pushbutton 2 spring ret. pushbuttons 3 spring ret. pushbuttonsContact(s) NO NC NO+NC NO+NC+NOColour of pushbutton(s) p green p red p green + p red p green + p red + p blackMetal control stations Dimensions, W x D x H 80 x 77 x 80 mm 80 x 77 x 130 mm 80 x 77 x 175 mmFixings: 4 x Ø 5.6 mm, centres 50 x 65 mm 50 x 115 mm 50 x 160 mmReferences XAWF100EX XAWF110EX XAWF210EX XAWF310EXPlastic control stations Dimensions, W x D x H 85 x 70 x 146 mm 85 x 70 x 226 mmFixings: 4 x Ø 5.6 mm, centres 70 x 105 mm 70 x 108 mmReferences XAWG100EX XAWG110EX XAWG210EX XAWG310EX23456TypeComplete control stationsType of operator Ø 22 selector switch or key switch with metal bezel Ø 40 mushroom head Emergency stopConformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0023 / D-Ex tD A21 IP65 T85°CTemperature range – 20...+ 60°CDegree of protectionIP65Connection1 entry fitted with ISO M20 cable glandRated operational characteristics of contact blocksAC15; A600 (Ue = 600 V, Ie = 1.2 A or Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 ADC13; Q600 (Ue = 600 V, Ie = 0.1 A or Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Function 1 function, Start/Stop Emergency stopComposition 1 selector switch (1) 1 key switch (1) 1 Ø 40 mushroom head 1 Ø 40 mushroom head 1 push/pull Ø 40standard black handle key n° 455 turn to release key release with trigger actionContact NO+NC NO+NC NC+NC NC+NC NC+NCColour of operator p black p black p red p red p redMetal control stations Dimensions, W x D x H 80 x 77 x 80 mmFixings: 4 x Ø 5.6 mm, centres 50 x 65 mmReferences XAWF130EX XAWF140EX XAWF174EX XAWF184EX XAWF198EXPlastic control stations Dimensions, W x D x H 80 x 70 x 146 mmFixings: 4 x Ø 5.6 mm, centres 70 x 105 mmReferences XAWG130EX XAWG140EX XAWG174EX XAWG184EX XAWG198EX(1) 2 position stay put78910Other characteristics: please refer to the “Human-Machine Interface components” catalogOther versions: please consult our Customer Care Centre.10/15


MagelisSmall PanelMagelis XBT Nwith matrix screen (1)1TypeCharacteristics2345Conformity Directive ATEX 94/9/CE, EN 60079-15, EN 50281-1-1 + A1, IEC 61241-0, EN 61241-1Zone D (dust) 22EC type examination certificate number / marking INERIS 05ATEX3016X / G D EEx nA nC IIC T5 - Ex tD A22 IP65 T100°CDisplay Capacity 2 lines, 20 characters 1 to 4 lines, 5 to 20 charactersType Back-lit LCD Back-lit LCD Back-lit LCDgreen 3 colours greengreen, orange, redData entryVia keypad with 8 keys (4 customizable keys)Function Representation of variables AlphanumericAlarm log No Yes Yes Yes YesCommunication Serial link 1 RJ45 (RS 232 - RS 485) 1 Sub-D25 (RS 232 - RS 485)Downloadable protocols Uni-TE, Modbus Master Uni-TE, Modbus Master, Siemens, ModbusRockwell,Omron, MitsubishiDevelopment softwareVijeo Designer Lite (on Windows 2000 and XP)Dimensions W x D x H132 x 37 x 74 mmCompatibility with PLCsTwido, Modicon TSX Micro,Modicon Premium, Modicon M340Twido, Modicon TSX Micro,Modicon Premium, Modicon Quantum,Motor starterTesys Model UModicon Momentum, Modicon M340Supply voltages 5 VDC or PLC power supply 24 VDCReferences XBTN200 XBTN400 XBTN410 XBTN401 XBTNU400(1) Except XBTN200: alphanumeric screen.67891010/16Other versions: please consult our Customer Care Centre.


Small PanelMagelis XBT Rwith matrix screen1TypeCharacteristicsConformity Directive ATEX 94/9/CE, EN 60079-15, EN 50281-1-1 + A1, IEC 61241-0, EN 61241-1Zone D (dust) 22EC type examination certificate number / marking INERIS 05ATEX3016X / G D EEx nA nC IIC T5 - Ex tD A22 IP65 T100°CDisplay Capacity 4 lines, 20 charactersTypeBack-lit LCDgreenBack-lit LCD, 3 coloursgreen, orange, redData entryVia keypad with 20 keys (12 customizable keys)Function Representation of variables AlphanumericAlarm log Yes Yes YesCommunication Serial link 1 RJ45 (RS 232 - RS 485) 1 Sub-D25 (RS 232 - RS 485)Downloadable protocols Uni-TE, Modbus Master Uni-TE,Modbus Master/Slave (1), Siemens, Rockwell,Omron, MitsubishiDevelopment softwareVijeo Designer Lite (on Windows 2000 and XP)Dimensions W x D x H137 x 37 x 118 mmCompatibility with PLCsTwido, Modicon TSX Micro,Modicon Premium, Modicon M340Twido, Modicon TSX Micro, Modicon Premium, Modicon Quantum,Modicon Momentum, Modicon M340Supply voltages 5 VDC or PLC power supply 24 VDCReferences XBTR400 XBTR410 XBTR411(1) for XBTR411 only2345Magelis XBT RTwith semi-graphic and touchscreen67TypeCharacteristicsConformity Directive ATEX 94/9/CE, EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-1Zone D (dust) 22EC type examination certificate number / marking INERIS 07ATEX3019X / G D Ex nA nC IIC T6 - Ex tD A22 IP64 T85°CDisplay Capacity 10 lines, 33 charactersType Back-lit LCD green Back-lit LCD green, orange, redData entry Via keypad with 12 keys (10 customizable keys) Via keypad with 12 customizable keysFunctions Representation of variables Alphanumeric, bargraph, curves, button and lightAlarm log Yes YesCommunication Serial link 1 RJ45 (RS 232 - RS 485) 1 RJ45 (RS 232 - RS 485)Downloadable protocolsUni-TE, Modbus Master, Siemens, Rockwell,Omron, MitsubishiDevelopment softwareVijeo Designer Lite (on Windows 2000 and XP)Dimensions W x D x H137 x 37 x 118 mmCompatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon M340, Modicon QuantumSupply voltages 5 VDC or PLC power supply 24 VDCReferences XBTRT500 XBTRT5118910Other versions: please consult our Customer Care Centre.10/17


MagelisAdvanced PanelMagelis XBT GTwith 3.8” touchscreen1TypeCharacteristics23456Conformity Directive ATEX 94/9/CE, EN 60079-15, EN 61241-0, EN 61241-1, EN 60079-0 (1)Zone D (dust) 22EC type examination certificate number / marking INERIS 06ATEX3024X / INERIS 08ATEX3024X / INERIS 06ATEX3024X / INERIS 08ATEX3024X / INERIS 08ATEX3024X /G D EEx nA nC IIC T4 - Ex tD A22 IP64 T135°CDisplay LCD screen size 3.8”Type STN monochrome, amber or red TFT colourFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 RJ45 (RS 232 - RS 485)Networks – Ethernet, IEEE 802.3 Ethernet, IEEE 802.310 BASE-T, RJ45 10/100 BASE-T, RJ45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows Vista, XP and 2000)Dimensions W x D x H130x41x104mmCompatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotNoUSB port – 1 – 1 1Built-in Ethernet TCP/IP No YesSupply voltage24 VDCReferences XBTGT1100 XBTGT1105 XBTGT1130 XBTGT1135 XBTGT1335(1) Does not take effect for XBTG1100 and XBTG1130Magelis XBT GT with 5.7” touchscreen78910TypeTypeCharacteristicsConformity Directive ATEX 94/9/CE, EN 60079-15, EN 61241-0, EN 61241-1Zone D (dust) 22EC type examination certificate number / marking INERIS 06ATEX3024X / G D EEx nA nC IIB T3 - Ex tD A22 IP64 T200°CDisplay LCD screen size 5.7”Type Back-lit STN, monochrome STN, colour TFT, colourblue black and white 4096 colours 65536 coloursFunctions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 Sub-D9 (RS 232/RS 422 - RS 485) + 1 RJ45 (RS 485)Networks – Ethernet, IEEE 802.3 – Ethernet, IEEE 802.310/100 BASE-T, RJ45 10/100 BASE-T, RJ45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCP/IPDevelopment soft ware Vijeo Designer VJDpppTGpVppM (on Windows Vista, XP and 2000)Dimensions W x D x H167.5x60x135mmCompatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340, Modicon Momentum«Compact Flash» card slot No YesUSB port 1Video inNoBuilt-in Ethernet TCP/IP No No Yes No YesSupply voltage24 VDCReferences XBTGT2110 XBTGT2120 XBTGT2130 XBTGT2220 XBTGT233010/18Other versions: please consult our Customer Care Centre.


Advanced PanelMagelis XBT GTwith 7.5”, 10.4”, 12.1”,15” touchscreen1TypeCharacteristicsConformity Directive ATEX 94/9/CE, EN 60079-15, EN 61241-0, EN 61241-1Zone D (dust) 22EC type examination certificate number / marking INERIS 06ATEX3024X / G DINERIS 06ATEX3024X / DEEx nA nC IIB T4 - Ex tD A22 IP64 T135°CEx tD A22 IP64 T135°CDisplay LCD screen size 7.5” 10.4” 12.1” 15”Type (colour) STN TFT TFT STN TFT TFT TFT TFT TFTNumber of colours 4096 65536 65536 4096 65536 65536 65536 65536 65536Functions Representation of variables Alphanumeric, bitmap, bargraph, gauge, button, light, clock, flashing light, keypadCurves / Alarm logsYes, with log / Yes, incorporatedCommunication Serial link 1 Sub-D9 (RS 232/RS 422 - RS 485) + 1 RJ45 (RS 485)Networks Ethernet, IEEE 802.3 10/100 BASE-T, RJ 45Downloadable protocolsMitsubishi (Melsec), Omron (Sysmac), Rockwell Automation (Allen Bradley), Siemens (Simatic)Uni-TE, Modbus, Modbus TCP/IPDevelopment software Vijeo Designer VJDpppTGpVppM (on Windows Vista, XP and 2000)Dimensions W x D x H (mm) 215x60x170 313x56x239 271x57x213 313x56x239 395x60x294Compatibility with PLCsTwido, Modicon TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340«Compact Flash» card slotYesUSB port 1 1 1 2 2 2 2 2 2Video in No No Yes No No Yes No Yes YesBuilt-in Ethernet TCP/IPYesSupply voltage24 VDCReferences XBTGT4230 XBTGT4330 XBTGT4340 XBTGT5230 XBTGT5330 XBTGT5340 XBTGT6330 XBTGT6340 XBTGT73402345678910Other versions: please consult our Customer Care Centre.10/19


PreventaEmergency stops and foot switchesCable (tripwire) operated Emergency stops1For operating cable up to 50 m longLatching, without indicator light234Conformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0015 / D-Ex tD A21 IP65 T85°CMechanical durability (millions of operating cycles) 0.01Temperature range – 20...+ 60°CDegree of protectionIP65Connection3 entries for ISO M20 cable glandRated operational characteristics AC15; A300 (Ue = 240 V, Ie = 3A)/DC13; Q300 (Ue = 250 V, Ie = 0.27 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Dimensions, W x D x H 229 x 82 x 142 mm 229 x 105 x 142 mmReset By booted pushbutton By key release pushbutton (key n° 421)Operating cable length ≤ 50 m ≤ 50 mOperating cable anchoring point To left To right To left To rightReferences NC+NO slow break XY2CE2A250EX XY2CE1A250EX XY2CE2A450EX XY2CE1A450EXNC+NC slow break XY2CE2A270EX XY2CE1A270EX XY2CE2A470EX XY2CE1A470EX5Foot switches, metal67TypeSingle pedal switches8910Conformity Directive ATEX 94/9/EC, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0025 / D-Ex tD A21 IP65 T85°CMechanical durability (millions of operating cycles) 5Temperature range – 20...+ 60°CDegree of protectionIP66Connection 2 entries for n° 16 (Pg 16) cable gland (1)Rated operational characteristics AC15; A300 (Ue = 240 V, Ie = 3 A)/DC13; Q300 (Ue = 250 V, Ie = 0.27 A)Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Dimensions, W x D x H104 x 172 x 59 mmColour Blue OrangeContact operation 1 step 2 step 1 step 2 stepReferences 1 NC+NO XPEM110EX – XPER110EX –2 NC+NO XPEM111EX XPEM211EX XPER111EX XPER211EX(1) 1 entry fitted with blanking plug, 1 entry fitted with n° 16 (Pg 16) cable glandOther characteristics: please refer to the “Machine safety” catalog10/20Other versions: please consult our Customer Care Centre.


PreventaSafety switchesand actuators3-pole contactSlow break1NC+2NO3-pole contactSlow break2NC+1NOISO entry(to EN 50262)Position of the contactwhen the actuator is inthe head of the switchMetal switches typeXCSA/B/C, 1 x ISO M20 cable entryWith head Without locking Interlocking, unlocking by button Interlocking, unlocking by key lockConformity Directive ATEX 94/9/CE, EN 50014, EN 50281-1-1, pr IEC 61241-0, pr IEC 61241-1Zone D (dust) 21 - 22EC type examination certificate number / marking INERIS 04ATEX0014X / D-Ex tD A21 IP67 T85°CActuation speed (min → max)0,1 m/s → 0,5 m/sDegree of protection IP 67Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300Temperature range-20…+60°CDimensions (body+head) W x D x H 40 x 44 x 113.5 mm 52 x 44 x 113.5 mm 52 x 44 x 113.5 mmShort-circuit protectionBy 10 A cartridge fuse type gG (gl)Complete switch 1NC+2NO XCSA502EX XCSB502EX XCSC502EX2NC+1NO XCSA702EX XCSB702EX XCSC702EXAccessories1234Straight actuator Wide actuator Pivoting actuatorFor safety switches XCSA/B/C/E Actuators Door lockReferences XCSZ01 XCSZ02 XCSZ03 XCSZ055Coded magnetic6WHBKWHBKBNBUBNBUPlastic switches typeConformityContact1NC+1NOstaggeredContact2NCstaggeredContact states shownare whilst the magnet isin front of the switchXCSDM coded magnetic, Pre-cabled, L = 2 mRectangular without LEDDirective Atex 94/9/CE, EN 50281-1.1 & 1.2, EN/IEC 61241-0, EN/IEC 61241-1, EN/IEC 60304, EN 1088, EN954-1Zone D (dust)0-1-2/20-21-22*(according to protection mode, mD or ia).EC type examination certificate number / marking INERIS 04ATEX0036 / GD-Ex tD A21 IP67 T135°CSwitches for actuationFace to face, face to side, side to sideDegree of protection IP 66 + IP 67Type of contactREEDRated operational characteristicsUe = 24 VDC, Ie = 100 mATemperature range-20…+60°CDimensions W x D x H16 x 7 x 51 mmOperating zone (4) Sao = 5 / Sar = 15Short-circuit protectionBy 10 A cartridge fuse type gG (gl)Switch with coded magnet 1NC+1NO staggered XCSDMC5902EX2NC staggeredXCSDMC7902EX78910Other versions: please consult our Customer Care Centre.10/21


Automation platformWeighing system for Modicon Premium123Module typeISP PlusSupplied calibratedConformity Directive ATEX 94/9/EC, EN 50014, EN 50020, EN 50039, EN 50284, EN 50281-1-1Zone D (dust) Mounted outside zone (to be used in conjunction with products for zone 21 or 22)EC type examination certificate number / marking LCIE 03ATEX6399X / SYST GD-EEx ib IIC T6 or IIB T6ConnectionBy connectors: Sub-D 15-way male for sensors and Sub-D 9-way male for transfer of weightsLoad cell inputs50 measurements (for 1 to 8 load cells)Outputs2 discrete and 1 RS 485 for displayReferences Without display TSXISPY101With display TSXXBTH100 TSXISPY11145Intrinsically safe I/O modules for ModiconQuantum6789Module typeInputs/outputsDiscreteAnalogueConformity Directive ATEX 94/9/EC, EN 50014, EN 50020, EN 50284, EN 50281-1-1Zone D (dust) Mounted outside zone (to be used in conjunction with products for zone 20, 21 or 22)EC type examination certificate number / marking SIRA 02ATEX2345X / GD-[EEx ia] IIC; Ta = - 20…+ 60 °CConnectionBy screw terminal block 140XTS33200 (to be ordered separately)Number of inputs 8 – 8 –Number of outputs – 8 – 8Signal inputs – – Thermal probes 0…25/20 mAThermocouple (1) 4…25 mAResolution 12 bits + sign 0…25,000 points 15 bitsReferences 140DII33000 140DIO33000 140AII33000 140AII33010 140AIO33000(1) Type J, K, E, T, S, R, B, mV1010/22Other versions: please consult our Customer Care Centre.


Notes1234567891010/23


Schneider Electric Industries SASHead Office35, rue Joseph Monier - CS 30323F92500 Rueil-Malmaison CedexFrancewww.schneider-electric.comThe information provided in this documentation contains general descriptions and/or technicalcharacteristics of the performance of the products contained herein. This documentation is notintended as a substitute for and is not to be used for determining suitability or reliability of theseproducts for specific user applications. It is the duty of any such user or integrator to perform theappropriate and complete risk analysis, evaluation and testing of the products with respect to therelevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates orsubsidiaries shall be responsible or liable for misuse of the information contained herein.Design : IGS-CPPhotos : Schneider ElectricPrint :DIA1ED2040506ENART. 96001502/2011 - V8.0