<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong><strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM 2.4 to 2.11Liebert MPH TM 2.12 to 2.17Knürr DI-STRIP ® 2.18 to 2.57Inline Metering (IMS) 2.58 to 2.642.1


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Safe, efficient and economical:<strong>Rack</strong> <strong>PDUs</strong> from <strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong>PDU product series overview:A reliable power supply is particularlyimportant in a server rack! <strong>Emerson</strong> <strong>Network</strong><strong>Power</strong>'s "<strong>Power</strong> Distribution Units"(PDU) provide the highest possible levelof safety, security and availability withtheir robust electro-mechanical setup.The rack <strong>PDUs</strong> ensure a sound economicalbenefit. The Liebert MPX TM 'smodularity also enables requirementsorientedand constantly compatibleexpansion.The rack <strong>PDUs</strong> provide the perfecteconomical solution for every specificrequirement and exceptional efficiencywith numerous technical features.BASICMANAGEDFeatures:■ High stability and torsional strength provided with closed sheet steelextrusions and ideal integration into Knürr rack systems.■ Best possible conductivity: continuous brass busbars with many models.■ Double spring contacts for shock hazard-proof and low contactresistance.Additional features:■ Highest possible safety, security and availability with an operatingtemperature of max. 55°C.■ Extensive measurement functions (power, current, voltage and energy),with higher measurement accuracy of up to ± 1%.■ Remote-switchable outputs with many models.■ Same communication cards used as with Liebert MPX, which meanssame software interface as with administration.■ Up to 4 Liebert MPX/MPH can be controlled via one IP.■ External sensors and a display can also be connected.Interacting with rack <strong>PDUs</strong>, rack monitoringsystems and cooling systems, Liebert NFORMguarantees the monitoring and controlling ofall relevant infrastructure parameters in serverrooms and data centers, alarms as required, andeven intercepts controlling to prevent damages.ADAPTIVEAdditional features:■ The Liebert MPX is a modular PDU; input and output modules can beflexibly equipped as required.■ Additional wiring between the module is not required; a fixed databus isintegrated on a continuous busbar.■ Highest power density up to max. 3 x 63 A per bar possible.■ Possible failures can be detected early on with additional monitoring(N-conductor, apparent power, crest factor and power factor).■ Depending on the output module, measuring and remote switching ispossible up to output level, which allows each server to be monitored.■ The output modules can be changed during running operation; there areno downtimes.2.2


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong><strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong><strong>PDUs</strong> Europe – product series overviewOverview : <strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong> EuropeKnürr DI-STRIP Basic <strong>Rack</strong> PDU ® Liebert MPH TM Liebert MPX TMManaged <strong>Rack</strong> PDUAdaptive <strong>Rack</strong> PDUFeatures Knürr Knürr Knürr Liebert MPH Liebert MPH Liebert MPX Liebert MPX Liebert MPX Liebert MPXDI-STRIP DI-STRIP M DI-STRIP RM Branch controlled Elementary Elementary Branch ReceptacleMonitored Phase monitored monitored managed<strong>Power</strong>distribution• • • • • • • • •Modular• • • •Display Fixed Fixed Modular Modular Modular Modular ModularRemote• • • • • •interfaceMeasuring at• • • • • • •input levelMeasuring per• • • •groupMeasuring peroutputSwitching per• •output•Measurement A A A,V,W,KWh, A,V,W,KWh, A,V,W,KWh, A,V,W,KWh, A,V,W,KWh,parameters Hz Hz Hz VA, Hz, VA, Hz,power factor power factor,crest factorInput 1ph + 3ph 1ph + 3ph 1ph + 3ph 1ph + 3ph 1ph + 3ph 1ph + 3ph 1ph + 3ph 1ph + 3ph 1ph + 3phpower max 32A max 32A max 32A max 32A max 32A max 63A max 63A max 63A max 63AOutputs IEC C13&C19 IEC C13&C19 IEC C13&C19 IEC C13&C19 IEC C13&C19 IEC C13&C19 IEC C13&C19 IEC C13&C19 IEC C13&C19Schuko Schuko Schuko Schuko Schuko Schuko SchukoSwitzerland Switzerland SwitzerlandFrance France FranceConnectionof different kinds• • • • •of sensorsThe Liebert MPX TM and Liebert MPH TMaccessories are largely identical, whichsimplifies administration!INFOYou will find further details and order numbers in our product catalog:www.<strong>Emerson</strong><strong>Network</strong><strong>Power</strong>.eu2.3


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong><strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong><strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM 2.4Products 2.8Liebert MPH TM 2.12Products 2.14INPUT POWER■ Configurable: 20 to 60 A (USA);16 to 63 A (EU);■ Single-phase and three-phase■ Cable routing from above and belowOUTPUT DISTRIBUTOR■ Scalable, combination-compatible and swappableduring operation■ Single-phase NEMA 5-20R, IEC-C13, IEC-C19, Schuko■ Load balanceKnürr DI-STRIP ® 2.18Knürr DI-STRIP ®DI-STRIP ® RM 2.22DI-STRIP ® M 2.23DI-STRIP High<strong>Power</strong> ® 2.24TDI-STRIP ® Triple<strong>Power</strong> ® 2.26DI-STRIP ® Blade<strong>Power</strong> ® 2.28DI-STRIP ® Pizza<strong>Power</strong> ® 2.291-1 10.3A119.5V 4.32kW 5.17kVA12345MODULARITY■ Input modules■ Output modules■ External display■ External sensorsMONITORING■ Various levels:Input level, module level, output level■ Temperature and humidity■ Door contacts and floating break input contactsDI-STRIP ® Classic 2.29DI-STRIP ® Compact 2.30DI-STRIP ® Protector 2.31DI-STRIP ® <strong>Power</strong> Cleaner 2.33DI-STRIP ® Safety Basic 2.34DI-STRIP ® Safety Standard 2.35DI-STRIP ® Master-Slave 2.36DI-STRIP ® Combi 2.37GST18, 1-phase 2.38GST18, 3-phase 2.40Knürr DI-STRIP ®Euro Plug System 2.42Knürr DI-STRIP ®for France 2.451-112345IP10.3A119.5V 4.32kW 5.17kVAREMOTE SOCKET CONTROL■ Socket levelLOCAL MONITORING■ Display for user■ Can also be mounted outside the rackREMOTE MONITORING■ Secure web and SNMP interfacesLiebert NformAvocent DSViewOVERLOAD PROTECTION■ Physically and electrically insulatedcircuit breakers for every socket moduleKnürr DI-STRIP ®for Switzerland 2.55Inline Metering System (IMS)Knürr DI-STRIP ® IMS 2.62Liebert MPX TM IMS 2.63Knürr Modular IMS 2.64RACK PDU ARRAY■ One IP for up to 4 rack <strong>PDUs</strong>■ Liebert MPX TM and Liebert MPH TM inthe same private networkFORM FACTOR■ Vertical mounting (0 U)■ Fits into trade standard 23/42 U racks and/or800 mm wide racks2.4


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TMAdaptive <strong>Rack</strong> PDU: Respondrequirements-oriented to every change!The Liebert MPX TM modular rack <strong>PDUs</strong>ystem is particularly impressivewith its maximum flexibility, highestpossible availability and low operatingcosts. With the Liebert MPX TM user canquickly and specifically react to newrequirements for power supply andrack management. The Liebert MPX TMgives users the ability to dimensiontheir rack PDU system so that allcurrent requirements are met first off.The system can be flexibly adjustedwhen requirements change later on.The Liebert MPX TM builds on a designthat is based on a power supply/communication bus and on input/output modules.Status display (RPC-BDM)Can be easily positioned at the optimum spot forthe individual rack; also functions outside the rack.This connected display can be mounted just as theuser wishes.■ Highest possible security andavailability with:- Redundant control electronicspower supply (with redundanttapping of various phase in the<strong>Power</strong> Entry Module).- Fixed databus on the busbar (makingcable breaks a thing of the past).- With complete data tapping onthe PEM (without any additionalexternal monitoring devices).- Additional neutral conductormeasurement.- Crest factor measurement(mains quality evaluation,allowing power supply failuresto be identified early on).■ Maximum flexibility andscalability with:- Configuration of all modulesaccording to their requirements(patented quick fixing for safeinstallation).- One busbar for different networksand power levels – input modulecan be freely selected.- All other components are "hotswappable" in running operation.- Mobile display for reading all MPX TMdata on the rack.- Optical slot space display (easyserver slot space identification at thepush of a button).■ Highest possible power levels in allareas with:- <strong>Power</strong> illustration up to 28 kVA perbar and 55°C ambient temperature.- Only one IP address for up to 4 barswith 24 modules.- Plug&Play for numerous sensors.- Extensive monitoring with ameasuring accuracy of +/- 1% up tooutput level.- Module and sensor autodetectfunction with operating software.- Lowest possible MPX TM systempower loss.■ Perfect for blade servers andchanging environmentsData centers work more and morewith blade servers and require moreprocessor power on low rack space;cabling must be simplified; powerconsumption must be reduced.With the Liebert MPX TM the datacenter can quickly react to changes,which is why our product is the rightchoice for you infrastructure'sadministration.2.5


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM : Four equipment modelsfor different requirementsThe Liebert MPX TM modular rack PDUconsists of various modules. Thefoundation stone is a busbar, whichis responsible for the power andcommunication distribution to theindividual modules. The input poweris routed via the Liebert MPX TM <strong>Power</strong>Entry Module (Liebert MPX TM PEM) tothe Liebert MPX TM system. Differentoutput modules (Liebert MPX TMBranch Receptacle Modules, LiebertMPX TM BRM) are available as required.Four different variants can be set updepending on the busbars' equipping:1. Liebert MPX TM ElementaryModular basic power distribution withoutmeasurement and control function. Anupgrade to another equipment model isno problem!2. Liebert MPX TM Elementary PhasemonitoredModular power distribution withmeasurement on the input per outputmodule. An upgrade to the next lineup is possible by equipping with therespective output modules.3. Liebert MPX TM Branch monitoredModular power distribution withmeasurement on the input per outputmodule. An upgrade or downgrade toanother line is possible by equipping withthe respective output modules.4. Liebert MPX TM Receptacle managedModular power distribution withmeasurement on the input per outputmodule and per output. The individualoutputs can also be switched on and offremotely. A downgrade to another line ispossible by equipping with the respectiveoutput modules.A combination of the "ElementaryPhase monitored", "Branch monitored"and "Receptacle managed" lines on ashared busbar is also possible and isone of the exceptional features of theLiebert MPX TM . Interfaces for the networkcommunication, the sensors and/or thelocal display are provided by the Liebert<strong>Rack</strong> PDU Card (Liebert RPC) in the LiebertMPX TM PEM. The Liebert RPC Card enablesconnection to an optional RPC BasicDisplay Module (RPC BDM) to display thelocal status and alarms.Output moduleReceptacle ManagedBusbar(Liebert MPX TM PRC)Distributes power andcommunication signalsto all modules.Output module Branchmonitored(Liebert MPX TM BRM)Spacer for busbarsFills unused gaps until aLiebert MPX TM module isupgraded.Output module e.g.Elementary (LiebertMPX TM BRM)<strong>Power</strong> input module(Liebert MPX TM PEM)Routes the input powerand the data (dependingon the module type) to thebusbar system.2.6


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM ,equipment models in EuropeBusbarInput modulesOutput modulesElementaryOutput modulesBranch monitoredOutput modulesReceptacle managedOrder numberLiebert MPX TMElementaryLiebert MPX TMElementary PhasemonitoredLiebert MPX TMBranch monitoredLiebert MPX TMReceptacle managedLength 1035 MPXPRC-V1035XXX x x x xLength 1880 MPXPRC-V1880XXX x x x xMPXPEM-EHAEXQ30x1ph 32A fixed*MPXPEM-EHAAXQ30 x x x3ph 16A fixed3ph 32A fixedMPXPEM-EHAEXT30xMPXPEM-EHAAXT30 x x xMPXPEM-EHAEXR30xMPXPEM-EHAAXR30 x x x3ph 63A fixedMPXPEM-EHBEXZ30xMPXPEM-EHBAXZ30 x x xIEC-C13 L1 MPXBRM-EEBC7N1N x xIEC-C13 L2 MPXBRM-EEBC7N2N x xIEC-C13 L3 MPXBRM-EEBC7N3N x xIEC-C19 L1 MPXBRM-EEBC4O1N x xIEC-C19 L2 MPXBRM-EEBC4O2N x xIEC-C19 L3 MPXBRM-EEBC4O3N x xSchuko L1 MPXBRM-EEBC3P1N x xSchuko L2 MPXBRM-EEBC3P2N x xSchuko L3 MPXBRM-EEBC3P3N x xIEC-C13 L1 MPXBRM-EBBC6N1N xIEC-C13 L2 MPXBRM-EBBC6N2N xIEC-C13 L3 MPXBRM-EBBC6N3N xIEC-C19 L1 MPXBRM-EBBC4O1N xIEC-C19 L2 MPXBRM-EBBC4O2N xIEC-C19 L3 MPXBRM-EBBC4O3N xSchuko L1 MPXBRM-EBBC3P1N xSchuko L2 MPXBRM-EBBC3P2N xSchuko L3 MPXBRM-EBBC3P3N xIEC-C13 L1 MPXBRM-ERBC6N1N xIEC-C13 L2 MPXBRM-ERBC6N2N xIEC-C13 L3 MPXBRM-ERBC6N3N xIEC-C19 L1 MPXBRM-ERBC4O1N xIEC-C19 L2 MPXBRM-ERBC4O2N xIEC-C19 L3 MPXBRM-ERBC4O3N xSchuko L1 MPXBRM-ERBC3P1N xSchuko L2 MPXBRM-ERBC3P2N xSchuko L3 MPXBRM-ERBC3P3N x1xTemp. SN-Z01 x x x3xTemp. SN-Z02 x x x3xT. + 1xHum SN-Z03 x x xSensors1xTemp. Mod. SN-T x x xTemp/Hum Mod. SN-TH x x x2xDoor Mod. SN-2D x x x3xInput Mod. SN-3C x x xDisplay ext. RPCBDM-1000 x x xDifferent combinations possible!*When using 1ph input modulesthen only L1 output modules canbe equipped.Upgrade possible!Four equipment models2.7


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM - Input Module/<strong>Power</strong> SupplyDOS20153Elementary and Monitored type:- The MPX PEM is fixed on the MPX PRC andprovides the connection to the power supply.- Cable is connected fixed, 3 m long- With IEC60309 plug, 1Ph/N/PE 6h blue,3Ph/N/PE 6h redMonitored type:- The MPX PEM provides the connection to thedatabus for the data communication.- Integrated Liebert RPC-1000 communicationcard enables remote monitoring andmaintenance of MPH units.- Provides the following measured values of thephase inputs: effective power, current, voltage,frequency and consumption.- <strong>Power</strong> alarm functions for the individual phasesand their operating status are also supported.- Further important features: Three displays informthe user about the current status of eachindividual input.An acoustic alarm is activated with specificoverload conditions.- The communication card centralizes the LiebertMPX's local and remote administration.- There is administration via web and SNMP forsystems connected to the Ethernet.- Also serves as the connection point for versatilesupport options and devices, such as the displaymodule (RPC BDM), various sensors andconnection to other Liebert MPX or Liebert MPHsystems, for example.- Has RJ-45 ports for all connections and does notrequire any special cabling.- Supports 10 and 100 MBit Ethernet and provideson-site firmware upgrade.Technical data Interfaces:- RJ-45 LAN port (10/100 MBit) – forconnecting to the local network (LAN)via an Ethernet cable.- Expansion/administration port for local configurationusing a computer/laptop, for settingup a link-up of several <strong>PDUs</strong> (Liebert MPXor MPH).- Display port for connecting the RPC BDM(display module).- External sensor port for connecting optionalsensors.Supported technologies:- Web support, provides Liebert MPX controland management. Authorized users canview status information via their network.- SNMP support, provides Liebert MPX SNMPmanagement.- Easy integration in Liebert Nform, AvocentDSView and Nagios.Material/finishHousing: AluminumCover: Sheet steel<strong>Power</strong> contacts: SilveredDatabus contacts: Gilded(only Monitored type)DimensionsWidth: 75 mmHeight: 65 mmCable: 3 mCo l o rHousing: Aluminum/RAL7021 dark grayApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- BV GSSupply schedule1 MPX PEM power input moduleincl. connection cableincl. RPC-1000 communication card(only Monitored type)L W H U Feed Load rating Type Order no. UP220 75 65 Fixed 230VAC, max 32A Elementary MPXPEM-EHAEXQ30 1 unit220 75 65 Fixed 230/400VAC, max 16A Elementary MPXPEM-EHAEXT30 1 unit220 75 65 Fixed 230/400VAC, max 32A Elementary MPXPEM-EHAEXR30 1 unit266 75 65 Fixed 230/400VAC, max 63A Elementary MPXPEM-EHBEXZ30 1 unit220 75 65 Fixed 230VAC, max 32A Monitored MPXPEM-EHAAXQ30 1 unit220 75 65 Fixed 230/400VAC, max 16A Monitored MPXPEM-EHAAXT30 1 unit220 75 65 Fixed 230/400VAC, max 32A Monitored MPXPEM-EHAAXR30 1 unit266 75 65 Fixed 230/400VAC, max 63A Monitored MPXPEM-EHBAXZ30 1 unitDimensions in mm: L = Length, W = Width, S = Switch,n = Number of sockets, F1 = Standard side, F2 = Design side, 19”= Suitable for 19”installation, Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.8


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM BRM - Output ModuleDOS20153- The MPX BRM takes care of the power distributionto the individual consumers.- Each module taps a phase; this is color-identifiedon the module.- All modules are protected against overload witha 20A circuit breaker.- Changing the modules during operation enablesa user-defined installation, without having toshut down the Liebert MPX.- Up to 3 BRM output modules can be installed ona 1,035 mm PRC busbar; up to 6 BRM outputmodules can be installed on a 1,880 mm PRCbusbar.Type E - Elementary:- Module for power distribution via respectiveoutputsType B – Branch monitored:- Module for power distribution via respectiveoutputs with measuring function on module level- The MPX BRMs have an LED-ID indicator, whichclearly identifies every module with a number.- The modules are administered in the software- Provides the following measured values: power,current, voltage, apparent power, kWh and powerfactor- <strong>Power</strong> alarm functions and the operating statusare supportedType R – Receptacle managed:- Module for power distribution via respectiveoutputs with measuring function on modulelevel and output level- The MPX BRMs have an LED-ID indicator, whichclearly identifies every module with a number.- The modules are administered in the software- Provides the following measured values: power,current, voltage, apparent power, kWh,frequency, power factor and crest factor- <strong>Power</strong> alarm functions and the operating statusare supported- The individual outputs can be switched on andoff remotelyMaterial/finishHousing: AluminumCover: Sheet steel<strong>Power</strong> contacts: SilveredDatabus contacts: Gilded (only type B and R)DimensionsWidth: 75 mmHeight: 65 mmCo l o rHousing: Aluminum/RAL7021 dark grayApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- Innova GSSupply schedule1 MPX BRM Output ModuleOperating instructionsL n Outputs Load rating Phase Type Order no. UPper outputtapping266 7 IEC320 C 13 10A L1 E MPXBRM-EEBC7N1N 1 unit266 7 IEC320 C 13 10A L2 E MPXBRM-EEBC7N2N 1 unit266 7 IEC320 C 13 10A L3 E MPXBRM-EEBC7N3N 1 unit266 4 IEC320 C 19 16A L1 E MPXBRM-EEBC4O1N 1 unit266 4 IEC320 C 19 16A L2 E MPXBRM-EEBC4O2N 1 unit266 4 IEC320 C 19 16A L3 E MPXBRM-EEBC4O3N 1 unit266 3 Schuko CEE 7/4 16A L1 E MPXBRM-EEBC3P1N 1 unit266 3 Schuko CEE 7/4 16A L2 E MPXBRM-EEBC3P2N 1 unit266 3 Schuko CEE 7/4 16A L3 E MPXBRM-EEBC3P3N 1 unit266 6 IEC320 C 13 10A L1 B MPXBRM-EBBC6N1N 1 unit266 6 IEC320 C 13 10A L2 B MPXBRM-EBBC6N2N 1 unit266 6 IEC320 C 13 10A L3 B MPXBRM-EBBC6N3N 1 unit266 4 IEC320 C 19 16A L1 B MPXBRM-EBBC4O1N 1 unit266 4 IEC320 C 19 16A L2 B MPXBRM-EBBC4O2N 1 unit266 4 IEC320 C 19 16A L3 B MPXBRM-EBBC4O3N 1 unit266 3 Schuko CEE 7/4 16A L1 B MPXBRM-EBBC3P1N 1 unit266 3 Schuko CEE 7/4 16A L2 B MPXBRM-EBBC3P2N 1 unit266 3 Schuko CEE 7/4 16A L3 B MPXBRM-EBBC3P3N 1 unit266 6 IEC320 C 13 10A L1 R MPXBRM-ERBC6N1N 1 unit266 6 IEC320 C 13 10A L2 R MPXBRM-ERBC6N2N 1 unit266 6 IEC320 C 13 10A L3 R MPXBRM-ERBC6N3N 1 unit266 4 IEC320 C 19 16A L1 R MPXBRM-ERBC4O1N 1 unit266 4 IEC320 C 19 16A L2 R MPXBRM-ERBC4O2N 1 unit266 4 IEC320 C 19 16A L3 R MPXBRM-ERBC4O3N 1 unit266 3 Schuko CEE 7/4 16A L1 R MPXBRM-ERBC3P1N 1 unit266 3 Schuko CEE 7/4 16A L2 R MPXBRM-ERBC3P2N 1 unit266 3 Schuko CEE 7/4 16A L3 R MPXBRM-ERBC3P3N 1 unit2.9


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM PRC - <strong>Power</strong> Distribution Unit/Communication Bus- The MPX PRC is the foundation stone of theLiebert MPX PDU.- <strong>Power</strong> and data transfer buses are integratedfixed over the entire length of the MPX PRC.- The MPX BRMs (output modules) and theMPX PEM (<strong>Power</strong> Entry Module) are fixed onthe MPX PRC and depending on the typetake care of the modules' power feed,output, monitoring and management.Material/finishBusbars housing: AluminumBusbars: CopperDatabus: GildedDimensionsWidth: 68 mmHeight: 24 mmCo l o rHousing: AluminumApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- BV GSLoad ratingMax. current intensity: 3 x 63 ANominal voltage (L-N / L-L): 230 / 400 VACSupply schedule1 MPXTM PRC - <strong>Power</strong> Distribution Unit/Communication Bus1 mounting setDOS20153L W H U Model Order no. UP1035 68 24 23 1 PEM (220 mm) + 3 BRM MPXPRC-V1035XXX 1 unit1880 68 24 42 1 PEM (220/266 mm) + 6 BRM MPXPRC-V1880XXX 1 unitLiebert MPX TM /MPH TM SensorsDOS20153- The sensors are designed for tool-less installationin a Knürr Miracel <strong>Rack</strong>, but they can also beinstalled in any other rack.- "Fixed" type sensors are fixed to a cable.- "Modular" type sensors can be connected withthe delivered cable.- Are affixed to the RPC-1000 communication card- Several sensors can be connected in rows (max.length: 20m)- Are automatically displayed in the Liebert MPX/MPH software- Temperature measuring range: 5-55°C- Accuracy: +/- 0.5°C- Humidity measuring range: 10 – 95%- Accuracy: +/- 3.5%NoteThe sensors are not required for operating theLiebert MPX or MPH, but they require theLiebert RPC-1000 (communication card)Supply schedule1 sensor with connection cableOperating instructionsCable length Type Model Order no. UP3660 Fixed Single temp. sensor SN-Z01 1 unit5180 Fixed Triple temp. sensor SN-Z02 1 unit5180 Fixed Triple temp. sensor + single humidity SN-Z03 1 unit2000 Modular Single temp. sensor SN-T 1 unit2000 Modular Triple temp. sensor + single humidity SN-TH 1 unit2000 Modular 2 x door contact - input module* SN-2D 1 unit2000 Modular 3 x digital input SN-3C 1 unit* Suitable door contact switch: Order no.: 06.108.115.92.10


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert RPC BDM - 1000 Display ModuleDOS20153- Provides the local display of the monitoreddata for all connected Liebert MPX and LiebertMPH systems.- Operated with the aid of a navigation switch.- Connected via a cable with the Liebert RPC,which provides the user the option of placingthe displays where they can be easily read inaccordance with the local space conditions.- An individual display can be used for up to fourLiebert MPX or Liebert MPH <strong>PDUs</strong>, which areconnected to a PDU array.NoteThe Display Module is not required foroperating the Liebert MPX or MPH, but ititself requires the Liebert RPC-1000(communication card)Supply schedule1 RPCBDM-1000 Display Module1 connection cable, 2 m1 mounting setL W H U Model Order no. UPRPCBDM-10001 unitLiebert <strong>Power</strong> distribution BRM Elementary Safety bracket- Safety brackets are available for strain relief fornetwork equipment power supply cords.- Safety brackets are sold in kits of 3 pieces.Supply schedule3 safety bracketsMounting materialHow suppliedflat-packed kitPlease noteSuitable for MPXBRM-EEBC7NxN (x=1,2,3)L W H U Model Order no. UP03.910.219.9 1 unitLiebert <strong>Power</strong> distribution BRM Cable Restraints kit- Cable restraints are available for strain relieffor network equipment power supply cords.- Cable restraints support most IEC C13 plugtypes with grip edge around the plug body(application confirmation required).- Cable restraints are sold in kits of 18 pieces.Supply schedule1 cable restraints kit (18 pieces).How suppliedFlat-packed kitPlease noteOptimum locking function only withconnection cable 04.000.051.9.Suitable only for MPXBRM-EBBC6NxNand MPXBRM-ERBC6NxN (x=1,2,3).L W H U Model Order no. UP03.910.216.9 1 unit2.11


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPH TMManaged <strong>Rack</strong>-PDU Systemsmonitoring and controlThe Liebert MPH TM Managed <strong>Rack</strong> PDU isa power supply system with monitoringand control functions. The housing consistsof a robust sheet steel enclosure,so that the PDU can be easily installedin a Knürr rack, or even into other enclosuresystems. The Liebert MPH TM canbe installed vertically or horizontally(19”), depending on the type. The PDUis delivered pre-installed with the samecommunication card (RPC-1000) asthe Liebert MPX TM . All Liebert MPX TMexternal modules can therefore be connected(e.g. sensors, display module).Up to four Liebert MPX TM /MPH TM can beconnected as rack PDU array to consolidatethe user's IP connection and thedevice monitoring.The Liebert MPH TM is available in twoequipment models:■ 1. Liebert MPH TM Type RMThe Liebert MPH TM Type RM is a monitoredPDU that monitors the phaseinputs. Measured per phase are:power, current, voltage and consumption.The power is also monitored pergroup (only 32A model).Different threshold values enable detailedalarm signals.■ 2. Liebert MPH TM Type CThe Liebert MPH TM Type C can alsoswitch the individual outputs on and offremotely.■ Highest possible security and availabilitywith:- <strong>Power</strong> illustration up to 22 kVA perPDU and 55°C ambient temperature- N-conductor current display with3-phase feed, which prevents feedcable overload.- Overload protection can be extendedper group with all 32A models;minimizes danger with cascadedPDU overload.- Setting alarm threshold values, whichmeans possible failures are detectedearly on.■ Flexibility with:- Connection option for an externaldisplay, which is easy to mountand can also be combined with theLiebert MPX TM .- Connection option for external sensors,which means temperatures andhumidity can be monitored.- Doors and alarm contacts can also bemonitored and displayed via externalinput contacts.- Versatile installation in the rack as 19”or space-saving vertical installation.- Same, compatible monitoring platformfor Liebert MPH TM and LiebertMPX TM .■ Low operating costs with:- <strong>Rack</strong> PDU array setup, which meansup to 4 MPH/MPX can be controlledwith one IP address; installation becomesquicker and easier.- Extensive energy and current measurement,which provides data requiredfor maximizing the power andcooling infrastructure.- Special switching technology of theindividual sockets, which reduces therack PDU's power loss.- Data interface with http and https protocol;no external software requiredfor configuration and monitoring. ThePDU can, however, also be integratedvia SNMP into other managementplatforms.2.12


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>INPUT POWER■ 20 to 30 A (USA);■ 16 to 32 A (EU);■ Single-phase and three-phaseOUTPUT DISTRIBUTOR■ NEMA 5-20R single-phase,■ IEC-C13 and IEC-C19;■ Combination systemsMODULARITY■ Communication card■ External display■ External sensors1-1 10.3A119.5V 4.32kW 5.17kVA12345MONITORING■ Input level■ Group level depending on type■ Temperature and humidity■ Door contacts and floating breakinput contactsREMOTE SOCKET CONTROL■ Socket levelIP10.3A1-1119.5V 4.32kW 5.17kVA12345LOCAL MONITORING■ Display for user■ Can also be mounted outside the rackREMOTE MONITORING■ Secure web and SNMP interfacesLiebert NformAvocent DSViewOVERLOAD PROTECTION■ Circuit breakers for every groupRACK PDU ARRAY■ One IP for up to 4 rack <strong>PDUs</strong>■ Liebert MPX TM and Liebert MPH TM in the same privatenetworkFORM FACTOR■ Vertical mounting (0 U)■ <strong>Rack</strong> installation■ Slimline 0 U form factor for positioningtwo <strong>PDUs</strong> in just one rack2.13


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPH TM <strong>Rack</strong> PDU- The Liebert MPH ® Type RM is a monitoredpower distribution unit that monitors the phaseinputs.Measured per phase are: power, current, voltageand consumption. The power is also monitoredper group (only 32A model).- The Liebert MPH® Type C can also switch theindividual outputs on and off remotely.- Integrated Liebert RPC 1000 communication cardenables remote monitoring and maintenance ofMPH units.- The RPC-1000 enables the interconnection ofseveral MPH or MPX units and the connection ofLiebert MPH ® with the Liebert MPX ® units formonitoring and administration.- The Liebert MPH ® can be monitored directly onsitewith the RPC BDM-1000, an optional displaymodule that is connected directly with thecommunication card. The monitoring unit can beflexibly mounted on the rack.Material/finishHousing: Sheet steel extrusionDimensionsWidth: 50 mm (vertical), 178 mm (19”)Height: 80 mm (vertical), 44 mm (19”)Cable Length: 3 mCo l o rHousing: RAL 7021 dark grayApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GSSupply schedule1 Liebert MPH ® Socket Strip (PDU)1 mounting bracketsOperating instructionsDOS20153L Type Input values Input plug Outputs IEC320 Order no. UP438* RM 230Vac, 16A IEC320 Sheet I 9xC 13 MPH-EBR09NXXO30 1 unit438* RM 230Vac, 32A IEC60309 1ph/N/PE 6h 9xC 13 MPH-EBR09NXXQ30 1 unit1730 RM 230Vac, 16A IEC320 Sheet I 27xC 13 MPH-EBV27NXXO30 1 unit1730 RM 230Vac, 16A IEC320 Sheet I 21xC 13/6xC 19 MPH-EBV27NOXO30 1 unit1730 RM 230Vac, 32A IEC60309 1ph/N/PE 6h 21xC 13/6xC 19 MPH-EBV27NOXQ30 1 unit1730 RM 230Vac, 32A IEC60309 1ph/N/PE 6h 27xC 13 MPH-EBV27NXXQ30 1 unit1730 RM 230/400Vac, 16A IEC60309 3ph/N/PE 6h 27xC 13 MPH-EBV27NXXT30 1 unit1730 RM 230/400Vac, 16A IEC60309 3ph/N/PE 6h 21xC 13/6xC 19 MPH-EBV27NOXT30 1 unit1730 RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 27xC 13 MPH-EBV27NXXR30 1 unit1730 RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 21xC 13/6xC 19 MPH-EBV27NOXR30 1 unit438* C 230Vac, 16A IEC320 Sheet I 9xC 13 MPH-ECR09NXXO30 1 unit438* C 230Vac, 32A IEC60309 1ph/N/PE 6h 9xC 13 MPH-ECR09NXXQ30 1 unit1730 C 230Vac, 16A IEC320 Sheet I 27xC 13 MPH-ECV27NXXO30 1 unit1730 C 230Vac, 16A IEC320 Sheet I 21xC 13/6xC 19 MPH-ECV27NOXO30 1 unit1730 C 230Vac, 32A IEC60309 1ph/N/PE 6h 21xC 13/6xC 19 MPH-ECV27NOXQ30 1 unit1730 C 230Vac, 32A IEC60309 1ph/N/PE 6h 27xC 13 MPH-ECV27NXXQ30 1 unit1730 C 230/400Vac, 16A IEC60309 3ph/N/PE 6h 27xC 13 MPH-ECV27NXXT30 1 unit1730 C 230/400Vac, 16A IEC60309 3ph/N/PE 6h 21xC 13/ 6xC 19 MPH-ECV27NOXT30 1 unit1730 C 230/400Vac, 32A IEC60309 3ph/N/PE 6h 27xC 13 MPH-ECV27NXXR30 1 unit1730 C 230/400Vac, 32A IEC60309 3ph/N/PE 6h 21xC 13/ 6xC 19 MPH-ECV27NOXR30 1 unit* (19”)2.14


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM /MPH TM SensorsDOS20153- The sensors are designed for tool-less installationin a Knürr Miracel <strong>Rack</strong>, but they can also beinstalled in any other rack.- "Fixed" type sensors are fixed to a cable.- "Modular" type sensors can be connected withthe delivered cable.- Are affixed to the RPC-1000 communication card.- Several sensors can be connected in rows(max. length: 20m).- Are automatically displayed in the LiebertMPX/MPH software.- Temperature measuring range: 5-55°C- Accuracy: +/- 0.5°C- Humidity measuring range: 10 – 95%- Accuracy: +/- 3.5%NoteThe sensors are not required for operatingthe Liebert MPX or MPH, but they requirethe Liebert RPC-1000 (communicationcard).Supply schedule1 sensor with connection cableOperating instructionsCable length Type Model Order no. UP3660 Fixed Single temp. sensor SN-Z01 1 unit5180 Fixed Triple temp. sensor SN-Z02 1 unit5180 Fixed Triple temp. sensor + single humidity SN-Z03 1 unit2000 Modular Single temp. sensor SN-T 1 unit2000 Modular Triple temp. sensor + single humidity SN-TH 1 unit2000 Modular 2 x door contact - input module* SN-2D 1 unit2000 Modular 3 x digital input SN-3C 1 unit* Suitable door contact switch: Order no.: 06.108.115.9Liebert RPC BDM - 1000 Display ModuleDOS20153- Provides the local display of the monitoreddata for all connected Liebert MPX and LiebertMPH systems.- Operated with the aid of a navigation switch.- Connected via a cable with the Liebert RPC,which provides the user the option of placingthe displays where they can be easily read inaccordance with the local space conditions.- An individual display can be used for up to fourLiebert MPX or Liebert MPH <strong>PDUs</strong>, which areconnected to a PDU array.NoteThe Display Module is not required foroperating the Liebert MPX or MPH, but ititself requires the Liebert RPC-1000(communication card).Supply schedule1 RPCBDM-1000 Display Module1 connection cable, 2 m1 mounting setL W H U Model Order no. UPRPCBDM-10001 unit2.15


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Accessories and software application,Liebert MPX TM and Liebert MPH TMInfrastructure managementSecure web and SNMP interfaces■ User-configured alarm threshold(3 threshold values per measuringpoint).■ Socket status and delayed switching.■ Electrical measurement: V, A, kW andkW/h, crest factor, Hz, power factor.■ <strong>Rack</strong> PDU array: Deviceconsolidation.■ PDU Explorer: intuitive hierarchicalinterface.■ PDU status display according to stripor socket.■ Device Explorer: search accordingto user-defined device names.■ Environment monitoring:temperature and humidity,floating contacts.Liebert Nform■ Control technology for Liebertdevices in the LAN.■ E-mail alarm and local notifications.■ Scalable software solution for ITenvironment.Web-based monitoring■ PDU parameters monitoring via webbrowser.■ No application-specific softwarerequired.■ Simultaneous display of up to 4 <strong>PDUs</strong>.Optional hardwareAvocent <strong>Rack</strong> <strong>Power</strong> Manager■ Alarm and incident administration ofall equipment at the site.■ Control technology in real-time.■ Individually adjustable user interface.■ Trend and alarm reports.<strong>Network</strong> management system■ Open standard solution.■ For all SNMP devices.■ Scalable software solution for allcompany sizes.Local display module – RPC-BDM■ Electrical and ambient parameters.■ 1 RPC BDM for up to 4 <strong>PDUs</strong> inthe array.■ PDU Explorer.■ Device Explorer:Liebert SN product family: <strong>Rack</strong> Sensors■ Temperature measurement withsingle or multiple sensors.■ Temperature and humiditymeasurement with multiple sensors.■ Door contact sensors and floatinginput contacts.2.16


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Flexible power distributionEasy integration of the rack <strong>PDUs</strong> into new or existing management platforms<strong>Rack</strong> PDU array (up to four systems)2.17


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong><strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong><strong>Rack</strong> <strong>PDUs</strong>INPUT POWER■ Single-phase or three-phase■ Up to 22 kVa■ Easy input supplyKnürr DI-STRIP ®DI-STRIP ® RM 2.22DI-STRIP ® M 2.23DI-STRIP High<strong>Power</strong> ® 2.24TDI-STRIP ® Triple<strong>Power</strong> ® 2.26DI-STRIP ® Blade<strong>Power</strong> ® 2.28DI-STRIP ® Pizza<strong>Power</strong> ® 2.29DI-STRIP ® Classic 2.29DI-STRIP ® Compact 2.30DI-STRIP ® Protector 2.31DI-STRIP ® <strong>Power</strong> Cleaner 2.33DI-STRIP ® Safety Basic 2.34DI-STRIP ® Safety Standard 2.35DI-STRIP ® Master-Slave 2.36DI-STRIP ® Combi 2.37GST18, 1-phase 2.38GST18, 3-phase 2.4010.3A1-1119.5V 4.32kW 5.17kVA12345OUTPUT DISTRIBUTOR■ NEMA 5-20R single-phase, IEC-C13 and C19,combination systems■ Schuko, France, SwitzerlandMODULARITY■ More connectivity with expansion unit forBasic <strong>Rack</strong> PDU GST18-<strong>PDUs</strong>FORM FACTOR■ Vertical mounting (0 U)■ <strong>Rack</strong> installationLOCAL MONITORING■ Fixed displayKnürr DI-STRIP ®Euro Plug System 2.42Knürr DI-STRIP ®for France 2.45Knürr DI-STRIP ®for Switzerland 2.55REMOTE MONITORING■ Secure web and SNMP interfacesLiebert NformOVERLOAD PROTECTION■ Circuit breakers/fuses per branchingcable/output as required2.18


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ®Basic <strong>Rack</strong> PDU: Robust <strong>PDUs</strong> withhelpful equipment featuresKnürr's Basic <strong>Rack</strong> <strong>PDUs</strong> are thesolution for every data center lookingfor robust, economical and flexiblerack concepts.For power distribution the KnürrDI-STRIP® product family meetsthe requirements of numerous ITapplications and other areas.Specially configured for the growingnumber of electronic componentsin network switching racks of serverracks. Available with differentaccessories, such as circuit breakers,overvoltage (surge) protection,mains filter, master-slave function,emergency off button, fault currentcircuit breaker, local and remotepower measurement, for example.■ Highest possible safety, securityand availability with:- Closed sheet steel extrusion, whichmeans high stability and torsionalstrength.- Extensive certification in acc. withinternational standard.- Double spring contacts for shockhazard-proof and low contactresistance.- Unbalanced load monitoring with3-phase feed prevents feed cableoverload (only DI-STRIP versionsM and RM).- Optimum load monitoring withservers' installation (only DI-STRIPversions M and RM).- Individual outputs backup withDI-STRIP Blade<strong>Power</strong> and Pizza<strong>Power</strong>.■ Maximum flexibility with:- Configurations and options withinternational compatibility- 2.5 m or 4 m power cable for morespatial flexibility.- Rotating display in 90° steps (onlyDI-STRIP versions M and RM).- Tool-less installation, which meansquick and easy extension in the rack(only DI-STRIP High<strong>Power</strong>).■ Extremely low operating costswith:- Quick and easy installation on therack requires minimum space andshorter installation time.- Automatic background lightreduction extends the display'sservice life and reduces the rackPDU power loss (only DI-STRIPmodels M and RM).- Especially flat housing extrusion,providing full accessibility tothe 19” level with 600 mm wideserver racks.All DI-STRIP M / RM with display rotationfor better reading.2.19


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® :Three equipment models forprecisely your requirementsKnürr DI-STRIP ® Elementary:Basic <strong>Rack</strong> PDU, Knürr DI-StripElementary ® for simple powerdistribution requirements. The <strong>PDUs</strong>are available in different structures,depending on the rack installationrequirements. Additional functionssuch as overvoltage (surge), mainsfilter, master-slave function,emergency off button and faultcurrent circuit breaker are alsoKnürr DI-STRIP M ® – local metered:Basic <strong>Rack</strong> PDU Knürr DI-STRIP M ®for simple power distributionrequirements and local powermeasurement for your data center.Available in single and three-phaseversions up to 22 kVa, with andwithout power measurement.Local power measurement features:■ M = power measurement (local)■ Tried, tested and proven DI-STRIP ®PDU with integrated local powermeasurement module.■ Large transparent LCD display.■ Meets the strictest EMC requirementswith radiation and irradiationinterference.■ Integrated unbalanced loadmonitoring with three-phase feed.■ Rotatable displays in 90° steps.■ Automatic background lightreduction.■ Optimum load monitoring withservers' installation.Knürr DI-STRIP RM ® – remote metered:Basic <strong>Rack</strong> PDU Knürr DI-STRIPRMRM ® for simple power distributionrequirements and remote powermeasurement for your data center.Available in single and three-phaseversions up to 22 kVa, with localand remote power measurement.Knürr DI-STRIP RM ® provides safe andreliable power supply in a robust,extruded enclosure.Remote power measurementmodule features:■ RM = power measurement (remote)Tried, tested and proven DI-STRIP ®PDU with integrated local powermeasurement module.■ Large transparent LCD display.■ Meets the strictest EMCrequirements with radiationand irradiation interference.■ Can be set for up to 3 threshold valuesand unbalanced load monitoring.■ Rotatable displays in 90° steps.■ Automatic background light reduction.■ Protocols: HTTP, SNMP, Syslog.All DI-STRIP High<strong>Power</strong> are equipped with especiallyflat housing extrusions and side cable entry. Thisenables installation without any loss of usable heightunits and cable entry from above and below. Fullaccessibility to the 19” level with 600 mm wide serverracks is also a given.2.20


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-Strip ®Equipment models in Europe1Full overview:Options Input power OutputsKnürr DI-STRIP ® equipment modelsKnürr DI-StripElementary ® Knürr DI-Strip M ®local meteredKnürr DI-Strip RM ®remote metered1Euro PlugSystem IEC 3201x16Aup to 3.68kVAIEC60320C13 & C19x x x1Classic1x16Aup to 3.68kVASchuko, France,Switzerlandx1Compact1x16Aup to 3.68kVASchuko, France,Switzerlandx x x1Protector FI1x16Aup to 3.68kVASchuko, France,Switzerlandx1Protector LS1x16Aup to 3.68kVASchuko, France,SwitzerlandxSample model1Protector FI / LS1x16Aup to 3.68kVASchuko, France,Switzerlandx21ProtectorEmergency STOP1x16Aup to 3.68kVASchuko, Francex1ProtectorEmergency STOPFI/LS1x16Aup to 3.68kVASchuko, Francex1<strong>Power</strong> Cleaner1x16Aup to 3.68kVASchuko, Francex1Safety Basic1x16Aup to 3.68kVASchuko, France,Switzerlandx1Safety Standard1x16Aup to 3.68kVASchuko, France,SwitzerlandxSample model311Master SlaveCombi1x16Aup to 3.68kVA1x16Aup to 3.68kVASchuko, FranceSchuko, Francexx1GST18 PlugSystem1x16A, 3x16Aup to 11kVASchuko, France,IEC60320x x x1Triple<strong>Power</strong>3x16Aup to 11kVAIEC60320C13 & C19Schukox x x2Blade<strong>Power</strong>1x32A, 3x32Aup to 22kVAIEC60320C13 & C19x2Pizza<strong>Power</strong>1x32A, 3x32Aup to 22kVAIEC60320C13 & C19Schukox x x3High<strong>Power</strong>1x32A, 3x32Aup to 22kVAIEC60320C13 & C19xxSample model2.21


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® RMDOS80002- Real RMS value display for the alternatingcurrent per phase- LCD display rotation in 90° steps- Display bright/dark switchover- Warning display for unbalanced load- Load changes signaling- Automatic background light dimming- Cable: 4 m H05VV-F5 G4 mm 2 (Pizza <strong>Power</strong>)- Cable: 2,5 m H05VV-F5 G / 2,5 mm 2(Triple <strong>Power</strong>)- Cable: 2,5 m H05VV-F36 / 1,5 mm 2(others)Data interface:- The plug strip can be integrated into the networkvia an RJ45 plug.- Access is possible without special software via aremote browser.- Three variable limit values and a warning forunbalanced loads can be specified.- The module enables access for up to 5 users oradministrators; access is password-protected.- The software displays the name and place of thePDU; this information can be entered by anadministrator.- The user can specify a static IP address or accessusing DHCP.- Firmware updates can be made via a webbrowser.- Supported protocols: HTTP, SNMP (Traps, SET,GET), SyslogMaterial/finish- Pizza<strong>Power</strong> model:Housing: sheet steel, zinc passivated,powder-coated- Other models:Housing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94),recyclableDimensionsWidth: 84 mm (Pizza<strong>Power</strong>), 44.4 mm (others)Height: 60 mm (Pizza<strong>Power</strong>), 44.4 mm (others)Co l o rPizza<strong>Power</strong> model:Housing: RAL 9005 blackOther models:Housing: RAL 7035 light grayPlastic parts: RAL 7021 dark grayApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GSSupply schedule1 socket strip (PDU) with remote ampere meter1 mounting bracketOperating instructionsL Type Input values Input plug Outputs IEC60320 Order no. UPC 13 C 19 Schuko733 DI-STRIP ® Compact RM 8 230Vac, 16A Schuko CEE 7/4 8 03.307.008.1 1 unit1183 DI-STRIP ® Compact RM 17 230Vac, 16A Schuko CEE 7/4 17 03.307.017.1 1 unit633 IEC320 RM9 230Vac, 16A Schuko CEE 7/4 9 03.607.009.1 1 unit933 IEC320 RM18 230Vac, 16A Schuko CEE 7/4 18 03.607.018.1 1 unit1133 DI-STRIP ® Triple<strong>Power</strong> RM 230/400Vac, 16A IEC60309 3ph/N/PE 6h 24 03.607.825.1 1 unit1833 DI-STRIP ® Triple<strong>Power</strong> RM 230/400Vac, 16A IEC60309 3ph/N/PE 6h 45 03.607.845.1 1 unit1233 DI-STRIP ® Triple<strong>Power</strong> RM 230/400Vac, 16A IEC60309 3ph/N/PE 6h 18 6 03.607.824.1 1 unit1833 DI-STRIP ® Triple<strong>Power</strong> RM 230/400Vac, 16A IEC60309 3ph/N/PE 6h 36 6 03.607.842.1 1 unit1111 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230Vac, 32A IEC60309 1ph/N/PE 6h 24 03.637.023.1 1 unit871 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230Vac, 32A IEC60309 1ph/N/PE 6h 12 4 03.637.016.1 1 unit1168 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230Vac, 32A IEC60309 1ph/N/PE 6h 21 4 03.637.025.1 1 unit563 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 6 03.637.006.1 1 unit995 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 6 12 03.637.018.1 1 unit1022 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 21 03.637.021.1 1 unit1157 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 18 6 03.637.024.1 1 unit1751 DI-STRIP ® Pizza<strong>Power</strong> ® RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 36 6 03.637.042.1 1 unit2.22


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® MDOS80002- With big transparent LCD display- Effective value display of alternating currents perphase (1-phase or 3-phase, depending on model)- LCD display rotation in 90° steps- Display can be switched bright or dark- Unbalanced-load warning display with 3-phasemodel- Load changes signaling- Automatic background light reduction- Cable: 4m H05VV—F 5 G 4mm² (Pizza<strong>Power</strong> M)- Cable: 2.5m H05VV-F 5 G 2.5mm² (Triple<strong>Power</strong> M)- Cable: 2.5m H05VV-F 3G 1.5mm² (DI-STRIPCompact M, DI-STRIP IEC320 M)Material/finishPizza<strong>Power</strong> ®: model:Housing: Sheet steel, zinc-passivated, powdercoatedOther models:Housing: closed sheet steel extrusion,zinc-passivated, powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC:EN61326-1, EN61000-3-2, EN61000-3-3- FCC Class B- CSA NRTL (Pizza<strong>Power</strong> m, Triple<strong>Power</strong> M,IEC320 M)- CB-Scheme (Triple<strong>Power</strong> M, DI-STRIPcompact M, IEC320M, ampere meter GST18i)Co l o rPizza<strong>Power</strong> M model:Housing: RAL 9005 blackOther models:Housing: RAL 7035 light grayPlastic parts: RAL 7021 dark graySupply schedule1 socket strip with ampere meter2 mounting brackets2 19” mounting brackets (with 19” installationoption)Note- Other models (e.g. 19” outputs) on requestL Type Input values Input plug Outputs IEC60320 Order no. UPC 13 C 19 Schuko483 DI-STRIP ® Pizza<strong>Power</strong> ® M 230Vac, 32A IEC60309 1ph/N/PE 6h 7 03.636.007.1 1 unit933 DI-STRIP ® Pizza<strong>Power</strong> ® M 230/400Vac, 32A IEC60309 3ph/N/PE 6h 21 03.636.021.1 1 unit1033 DI-STRIP ® Triple<strong>Power</strong> ® M 230/400Vac, 16A IEC60309 3ph/N/PE 6h 21 03.606.821.1 1 unit1833 DI-STRIP ® Triple<strong>Power</strong> ® M 230/400Vac, 16A IEC60309 3ph/N/PE 6h 45 03.606.845.1 1 unit1133 DI-STRIP ® Triple<strong>Power</strong> ® M 230/400Vac, 16A IEC60309 3ph/N/PE 6h 18 6 03.606.824.1 1 unit1733 DI-STRIP ® Triple<strong>Power</strong> ® M 230/400Vac, 16A IEC60309 3ph/N/PE 6h 36 6 03.606.842.1 1 unit483 DI-STRIP ® Compact M 230Vac, 16A Schuko 6 03.306.006.1 1 unit483 DI-STRIP ® IEC320 M 230Vac, 16A Schuko 9 03.606.009.1 1 unit233 DI-STRIP ® Ampere Meter 230Vac, 16A GST18 03.606.200.1 1 unit2.23


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ®High<strong>Power</strong> ®The Knürr DI-STRIP ® High<strong>Power</strong> is a solution for every datacenter with high power requirements and low space in therack. The special shape enables space-saving installation in therack. This means free access to the servers, even with 600 mmwide racks. Maintenance of the servers (e.g. power supplychanges) is possible at no further expense.The Knürr DI-STRIP ® product family meets the power distributionrequirements of many IT applications and other areas.Specially configured for the growing number of electroniccomponents in network switching racks of server racks. TheDI-STRIP ® High<strong>Power</strong> is available with and without remotepower measurement (DI-STRIP ® High<strong>Power</strong> RM).2.24


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® High<strong>Power</strong>Strong pointsFlexibilityWith or without remote powermeasurement.Easy expansion in the rack with toollessinstallation.3 m power cable for more spatialflexibility.RM model:Current values can be read via a bigtransparent LCD display.Rotating display in 90° steps; thedisplay can always be read the sameregardless of the installation direction.The power measurement modulecan be integrated into differentmanagement programs via differentprotocols (SNMP, http, Syslog).High availabilityMeets the strictest EMC requirementswith radiation and irradiationinterference. Robust and stable witha closed sheet steel housing.Reliable, robust solution.Extensive certification in acc. withinternational standard.RM model:Different threshold values can beflexibly specified; power values cantherefore be monitored and loaddrops can be signaled.With 3-phase <strong>PDUs</strong> the unbalancedload can be monitored, which meansthe neutral conductor is protectedfrom overloads.Low operating costsEspecially flat housing extrusion,providing full accessibility to the 19”level with 600 mm wide server racks.Server power supply changes are veryquick and easy.Quick and easy installation on the rackrequires minimum space and shorterinstallation time.RM model:Automatic background light reductionextends the display's service life andreduces power loss.Knürr DI-STRIP ® High<strong>Power</strong>DOS20153- Flat design provides access to the 19” level, evenwith 600 mm wide racks.- Individual backup for outputs (groups with 10 A).- Outputs divided into groups with max. 20 A pergroup- Modular expansion in the rack with tool-less PDUinstallation.Additional functions for High<strong>Power</strong> RM type(remote metered)- With big transparent LCD display- Effective value display of alternating current- LCD display rotation in 90° steps- Display can be switched bright or dark- Load changes signaling- Automatic background light reduction- See DI-STRIP RM for technical description for datainterfaceMaterial/finishHousing: Sheet steel, zinc-passivated, powdercoatedDimensionsWidth: 134 mmHeight: 47 mmCable: 3 mCo l o rHousing: RAL 9005 blackApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GSSupply schedule1 socket strip (PDU)1 integrated remote ampere meter(only High<strong>Power</strong> RM)2 mounting bracketOperating instructionsL Type Input values Input plug Outputs IEC60320 Order no. UPC 13 C 19 Schuko540 DI-STRIP ® High<strong>Power</strong> 230Vac, 32A IEC60309 1ph/N/PE 6h 20 4 03.632.100.8 1 unit850 DI-STRIP ® High<strong>Power</strong> 230/400Vac, 32A IEC60309 3ph/N/PE 6h 6 12 03.632.102.8 1 unit850 DI-STRIP ® High<strong>Power</strong> 230/400Vac, 32A IEC60309 3ph/N/PE 6h 18 6 03.632.103.8 1 unit540 DI-STRIP ® High<strong>Power</strong> RM 230Vac, 32A IEC60309 1ph/N/PE 6h 20 4 03.632.200.8 1 unit850 DI-STRIP ® High<strong>Power</strong> RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 6 12 03.632.202.8 1 unit850 DI-STRIP ® High<strong>Power</strong> RM 230/400Vac, 32A IEC60309 3ph/N/PE 6h 18 6 03.632.203.8 1 unit2.25


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Three Phase Knürr DI-STRIP ®Triple<strong>Power</strong> ®The Triple<strong>Power</strong> ® name represents the performance of ourlatest development. Die DI-STRIP ® Triple<strong>Power</strong> ® suppliesnetwork racks with three times the normal power. This requirementis generated by the increasingly higher packingdensities and constantly rising energy requirements in racks,which are often caused by aptly named "Blade Servers" or 1 U"Pizza Servers", more than 40 of which can be integrated intoa Knürr Miracel rack.The DI-STRIP ® Triple<strong>Power</strong> ® uses a classic 3-phase feed with3x16A, which it optimally distributes throughout the wholerack. The 23 U and 41 U standard lengths cover the entire rackheight range of the Knürr Smaract2 and Miracel rack families.In the maximum configurationlevel, up to 48 users cannow be connected to aDI-STRIP ® Triple<strong>Power</strong> ® (Eurosocket strip). With redundantfeed, 96A can consequentlybe provided in a 19” rack withonly two DI-STRIP ® Triple-<strong>Power</strong> ® .Dimensions in mm:L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side,19” = Suitable for 19” installation, Safe = Child-safeU = Standard height unit, UP = Unit of packagingReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 2003DOS20149DOS201482.26


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Triple<strong>Power</strong> ®Strong points1 Cost-consciousQuick and easy mounting on the rackextrusion.Costs reduction with mountingand wiring.2 Feed- 3x16A as standard- Ideal for implementing redundancy(e.g. 96 A)1 DOS20131 3 DOS201263 At a glancePhase assignment color coding(L1, L2, L3).4 InstallationOptimum distribution over the entirerack height(standard: 23 U and 41 U).Technical alternatives- For 3-phase GST18 system(see page 2.36).2 DOS20147 4 DOS20129DOS20126DI-STRIP ® Triple<strong>Power</strong> ® Euro Plug-In System, IEC 320with cable- Cable: H05VV-F 5 G 2.5 mm 2- Cable: 2.5 m(optional with IEC60309 plug, 3Ph/N/PE 6h)- Easy mounting on the rack extrusion- 3x16A feed as standard- Ideal for implementing redundancy (e.g. 96 Awith redundant feed)- Unmistakable phase assignment color-coding- Optimum distribution over the entire rack height(23 U and 41 U)- Alternative for 3-phase GST18 system(see page 170)Material/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94),recyclableApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS, CSA NRTL/C, CB-schemeCo l o rHousing: RAL 7035 light grayPlastic parts: RAL 7021 dark grayLoad rating100-240/173-415 VacInput: 3x 16 AOutput: 10 A (C 13)Output: 16 A (C 19)Approval symbols for IEC 320 3-way EurocombinationsVDE, UR, CSADimensionsHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Supply schedule1 socket strip2 mounting bracketL S n F1 19” Input values Input plug Outputs IEC60320 Order no. UPC 13 C 191033 24 • 230/400Vac, 16A Open end 24 03.600.024.1 1 unit1833 48 • 230/400Vac, 16A Open end 48 03.600.048.1 1 unit1033 24 • 230/400Vac, 16A IEC60309 3ph/N/PE 6h 24 03.600.824.1 1 unit1833 48 • 230/400Vac, 16A IEC60309 3ph/N/PE 6h 48 03.600.848.1 1 unit1133 24 • 230/400Vac, 16A IEC60309 3ph/N/PE 6h 18 6 03.600.524.1 1 unit1733 42 • 230/400Vac, 16A IEC60309 3ph/N/PE 6h 36 6 03.600.542.1 1 unit483 6 • • 230/400Vac, 16A IEC60309 3ph/N/PE 6h 6 03.600.506.1 1 unit2.27


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Three Phase – Knürr DI-STRIP ®Blade<strong>Power</strong> ®Pizza<strong>Power</strong> ®A new generation of the power distribution units of theDI-STRIP ® range now ensures even more power: Blade<strong>Power</strong> ®and Pizza<strong>Power</strong> ® for fail-safe power supply distribution innetwork racks.Increasingly higher packing densities and therefore constantlyincreasing energy requirements in server racks caused byblade servers or 1 U pizza servers will now be handledelectrically.Up to 35 kW dissipated heat can be removed from modernCoolTherm ® server racks. But how is the necessary powersupplied into the rack, which can cause such power losses?The <strong>PDUs</strong> (3x32 A) optimally distribute the required powerover the entire rack, with connection of up to 21 consumerspossible in the highest configuration level. 192 A can besupplied to the rack with redundant feed.Knürr DI-STRIP ®Strong pointsCost-consciousQuick and easy installation on theserver rack’s extrusion.Costs reduction with mountingand wiring.Feed- Single-phase 32 A and three-phase32 A.- ≤22 kVA- Ideal for providing redundancy(e.g. 192 A)Crystal clear assignmentUnmistakable phase assignmentcolor-coding (L1, L2, L3).InstallationOptimum distribution of bladecenter and pizza server supply witheasy power distribution unit (PDU)installation.AvailabilityPrevention of "Single Point of Failure"with individual fusing.CertificationDOS20153Knürr DI-STRIP ® Blade<strong>Power</strong> ®Technical data- EC 320 sockets (10 A and 16 A).- Individually fused via thermal circuit breaker thatcan be reset in acc. with IEC 60934- Cable: H05VV-F 5 G 4 mm 2- Cable: 4 m- With IEC60309 plug, 1Ph/N/PE 6h blue, 3Ph/N/PE6h redMaterial/finishHousing: sheet steel, zinc passivated, powdercoatedDimensionsHeight: approx. 60 mmHousing width: 84 mmCo l o rHousing: RAL 9005, blackApprovals- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CSA NRTL/C (only without plug)Load rating100-240 / 173-415 VacInput: 1x32 A or 3x32 AOutput: 10 A / 16 ASupply schedule1 socket strip (PDU)2 mounting bracket1 19” mounting bracket(additional with 19” installation option)Operating instructionsDOS20155L S n F1 19” Plug Model Order no. UP375 5 • • • Blade<strong>Power</strong>® PDU 1x 32 A 03.630.005.1 1 unit740 15 • • Blade<strong>Power</strong>® PDU 3x 32 A 03.630.015.1 1 unit375 5 • • Blade<strong>Power</strong>® PDU 1x 32 A 03.630.805.1 1 unit740 15 • Blade<strong>Power</strong>® PDU 3x 32 A 03.630.815.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.28


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Pizza<strong>Power</strong> ®Technical dataDOS20158DOS20159- Individually fused via thermal circuit breaker thatcan be reset in acc. with IEC 60934- Cable: H05VV-F 5 G 4 mm 2- Cable: 4 mMaterial/finishHousing: sheet steel, zinc-passivated, powdercoatedDimensionsHeight: approx. 60 mmHousing width: 84 mmHeight with cable: approx. 176 mmCo l o rHousing: RAL 9005, blackApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CSA NRTL/C (only without plug)Load rating100-240 / 173-415 VacInput: 1x32 A or 3x32 AOutput: 10 A (C 13)Output: 16 A (C 19)Supply schedule1 socket strip (PDU)2 mounting bracket1 19” mounting bracket(additional with 19 installation option)Operating instructionsL S n F1 19” Input values Input plug Outputs IEC60320 Order no. UPC 13 C 19400 7 • 230Vac, 32A IEC60309 1ph/N/PE 6h 7 03.631.007.1 1 unit400 7 • 230Vac, 32A Open end 7 03.631.807.1 1 unit720 16 • 230Vac, 32A IEC60309 1ph/N/PE 6h 12 4 03.631.124.1 1 unit960 24 • 230Vac, 32A IEC60309 1ph/N/PE 6h 24 03.631.240.1 1 unit1017 25 • 230Vac, 32A IEC60309 1ph/N/PE 6h 21 4 03.631.214.1 1 unit933 21 • 230/400Vac, 32A IEC60309 3ph/N/PE 6h 21 03.631.021.1 1 unit933 21 • 230/400Vac, 32A Open end 21 03.631.821.1 1 unit408 6 • 230/400Vac, 32A IEC60309 3ph/N/PE 6h 6 03.631.006.1 1 unit939 21 • 230/400Vac, 32A IEC60309 3ph/N/PE 6h 9 12 03.631.912.1 1 unit1362 36 • 230/400Vac, 32A IEC60309 3ph/N/PE 6h 36 03.631.360.1 1 unit1002 24 • 230/400Vac, 32A IEC60309 3ph/N/PE 6h 18 6 03.631.186.1 1 unitKnürr DI-STRIP ® ClassicStandard DIN 49 440DOS00403DOS00260With switch- Optionally with lit switch, 2-pole switching- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Optionally with Euro plug, IEC320 for UPSapplicationMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94)Internal conductor: full-length busbar, brassDimensionsSocket spacing: 100 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-scheme- VDECo l o rRAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketDOS00261Without switchDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 2003L S n F1 F2 19” Safe Model Order no. UP1783 17 • 03.300.067.1 1 unit1383 13 • 03.300.063.1 1 unit983 9 • 03.300.059.1 1 unit583 5 • 03.300.055.1 1 unit1733 • 16 • With switch 03.302.066.1 1 unit1333 • 12 • With switch 03.302.062.1 1 unit933 • 8 • With switch 03.302.058.1 1 unit533 • 4 • With switch 03.302.054.1 1 unit2.29


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® CompactStandard DIN 49 440DOS00401DOS00262DOS20020With switchWith switchWithout switch- Optionally with lit switch, 2-pole switching- 19” installation option (with length 483 mm)- 2 versions: Standard side panel or Design sidepanel- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plug- Optionally with Euro plug, IEC320 for UPSapplicationsMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-scheme- VDEColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketDOS20021DOS00263With switchWithout switchL S n F1 F2 19” Safe Model Order no. UP883 15 • 03.300.015.x 1 unit732 11 • 03.300.111.x 1 unit683 11 • 03.300.011.x 1 unit532 7 • • 03.301.107.x 1 unit532 7 • 03.300.107.x 1 unit03.300.007.x 1 unit483 7 • •483 8 • •382 4 • •382 4 •333 4 •03.300.008.1 1 unit03.301.104.x 1 unit03.300.104.x 1 unit03.300.004.x 1 unit883 • 14 • With switch 03.302.014.x 1 unit732 • 10 • With switch 03.302.110.x 1 unit683 • 10 • With switch 03.302.010.x 1 unit532 • 6 • • With switch 03.303.106.x 1 unit532 • 6 • With switch 03.302.106.x 1 unit483 • 6 • • With switch 03.302.006.x 1 unit483 7 • • With switch 03.302.007.1 1 unit382 • 3 • • With switch 03.303.103.x 1 unit382 • 3 • With switch 03.302.103.x 1 unit333 • 3 • With switch 03.302.003.x 1 unitKnürr DI-STRIP ® Compact UPSStandard DIN 49 440L S n F1 19” Input values Input plug Outputs Order no. UPSchuko CEE7/4483 8 • •483 8 • •230Vac, 10A ICE60320 Sheet E 8 03.300.308.1 1 unit230Vac, 16A ICE60320 Sheet I 8 03.300.408.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.30


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Protector FIStandard DIN 49 440DOS20065DOS00264With fault current circuit breakerWith fault current circuit breakerProtector FIRCCB for user protection- Protection with indirect contact as errorprotection by switching off with inadmissiblehigh contact voltage through contact withelectrical equipment- Protection with direct contact as back-upprotection- Residual operating current Ig = 10 mA foralternating and pulsating direct fault current- 19” installation option(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 78 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP883 13 • 03.304.013.1 1 unit683 9 • 03.304.009.1 1 unit03.304.005.1 1 unit483 5 • •Knürr DI-STRIP ® Protector LSStandard DIN 49 440DOS00692DOS00264With circuit breakerWith circuit breakerProtector LS- Circuit breaker for overload and short circuit- Protects cables and feeds with rapidswitching off with short circuit and defineddelayed cutoff with overload- Circuit breaker: 16 A- Tripping characteristic, type B, 2-pole- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 78 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-scheme- VDEColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundL S n F1 F2 19” Safe Model Order no. UP883 13 • 03.308.013.1 1 unit683 9 • 03.308.009.1 1 unit03.308.005.1 1 unit483 5 • •Replace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.31


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Protector FI / LSStandard DIN 49 440DOS00693DOS00264Protector FI / LS- RCCB and circuit breaker- Provides a combination of user, overload andshort circuit protection- Residual operating current Ig = 30 mA foralternating and pulsating direct fault current- Circuit breaker: 16 A- Tripping characteristic, type B, 2-pole- 19” installation option(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: Closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 78 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP883 13 • 03.310.013.1 1 unit683 9 • 03.310.009.1 1 unit03.310.005.1 1 unit483 5 • •Knürr DI-STRIP ® Protector Emergency STOPStandard DIN 49 440DOS20059- With 2-pole emergency stop switch for user protection- For protecting operating personnel- For manual emergency switching off of theconnected consumers- Phase and neutral conductors are safely separated- Switch must be specifically unlocked to restart- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-scheme- VDEDOS00486DOS00487Classic withemergency stop switchProtector withemergency stop switchMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: Classic: 100 mm, Compact: 50mmHeight: 101 mmColor combinationsFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP683 10 • Compact 03.326.010.1 1 unit483 6 • • Compact 03.326.006.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 pound1333 12 • Classic 03.326.062.1 1 unit933 8 • Classic 03.326.058.1 1 unitReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.32


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Protector Emergency Stop FI /LSStandard DIN 49 440DOS00456- With 2-pole emergency stop switch for userprotection- For protecting operating personnel- For manual emergency switching off of theconnected consumers- Phase and neutral conductors are safelyseparated- Switch must be specifically unlocked to restart- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationsFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayDOS00488Material/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing:Compact: 50 mmHeight: 101 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mAdditionally:With 2-pole fault current switch and circuitbreakerProvides a combination of user, overload andshort circuit protectionLoad rating100-240Vac/16 ASupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP683 8 • 03.328.008.1 1 unitKnürr DI-STRIP ® <strong>Power</strong> CleanerStandard DIN 49 440DOS20061DOS00266- High-frequency glitches are generally causedby switching processes in an operation from100 kHz to 5 MHz. This high-frequency rateoverloads the mains frequency and affectsadjacent electronic equipment. The mains filterattenuates this high-frequency rate.- The attenuation behavior is harmonized with thetypical interference spectrum.- The mains filter works in both directions. Thismeans that glitches from the equipment to thesocket strip are also filtered from the mains.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayTechnical dataNominal voltage: max. 250 Vac, 50 HzNominal current: max. 16 AFilter in acc. with VDE 0565-3 (EN 60939-1)Supply schedule1 socket strip2 mounting bracket2 19” mounting bracket (additional with19” installation option)Dimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 2003L S n F1 F2 19” Safe Model Order no. UP883 13 • 03.312.013.x 1 unit683 9 • 03.312.009.x 1 unit03.312.005.x 1 unit483 5 • •2.33


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Safety BasicStandard DIN 49 440DOS20068DOS00306DOS00270With overvoltage protectionWith overvoltage protectionWith overvoltage protection- For protecting against transient overvoltagesfrom the mains, which, for example, are causedby switching machines on and off.- With critical overvoltages the mains is separated.- Once the safety arrester has been triggered thegreen function display goes out. The socket stripcan then no longer be used.Send the socket strip to the manufacturer for thesafety arrester to be replaced!The safety effect of the type 3 test category andrequirements category "D" is to protect theequipment, i.e. precision protection.The protection devices of the test and requirementscategories 1 and 2 and B and C must bepreconnected in the building installation to ensureoptimum protection.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayTechnical dataTest category: Type 3- In acc. with DIN EN 61643-11Requirements class: D- In acc. with VDE 0675-6Mains voltage: 230 VACNominal current: max. 16 ACut-off discharge current (8/20 μs): 10 kAResponse time: ‹ 25 nsProtection level(with 100 A varistor peak current):- L with respect to N: ‹ 800 V- L/N with respect to PE: ‹ 1500 VDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Supply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP732 10 • 03.316.110.1 1 unit683 10 • 03.316.010.x 1 unit532 6 • • 03.317.106.1 1 unit532 6 • 03.316.106.1 1 unit03.316.006.x 1 unit483 6 • •432 4 • •432 4 •383 4 •03.317.104.1 1 unit03.316.104.1 1 unit03.316.004.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.34


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Safety StandardStandard DIN 49 440DOS20069DOS00307DOS00271With overvoltage protectionand mains filterWith overvoltage protectionand mains filter- The "Safety Standard" models consist of acombined overvoltage (surge) protection/mainsfilter element.- For protecting against transient overvoltagesfrom the mains, which, for example, are causedby switching machines on and off.- With critical overvoltages the mains is separated.- Once the safety arrester has been triggered thegreen function display goes out. The socket stripcan then no longer be used. Send the socket stripto the manufacturer for the safety arrester to bereplaced!- The safety effect of the type 3 test category andrequirements category "D" is to protect theequipment, i.e. precision protection.The protection devices of the test andrequirements categories 1 and 2 and B and Cmust be preconnected in the building installationto ensure optimum protection.- High-frequency glitches are generally causedby switching processes in an operation from100 kHz to 5 MHz.- This high-frequency rate overloads the mainsfrequency and affects adjacent electronicequipment. The mains filter attenuates this highfrequencyrate.- The attenuation behavior is harmonized with thetypical interference spectrum.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: HO5VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayTechnical dataMains voltage: 230 VACNominal current: max. 16 ACut-off discharge current (8/20 μs): 10 kAResponse time: ‹ 25 nsProtection level(with 100 A varistor peak current):- L with respect to N: ‹ 800 V- L/N with respect to PE: ‹ 1500 VOvervoltage protection- Test category: Type 3in acc. with DIN EN61643-11- Feature class: D- In acc. with VDE 0675-6Mains filter- In acc. with VDE 0565 (EN 60939)Supply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP883 • 13 • With switch 03.318.013.x 1 unit732 • 9 • • With switch 03.319.109.x 1 unit732 • 9 • With switch 03.318.109.x 1 unit683 • 9 • With switch 03.318.009.x 1 unit532 • 5 • • With switch 03.319.105.x 1 unit532 • 5 • With switch 03.318.105.x 1 unit483 • 5 • • With switch 03.318.005.x 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.35


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Master-SlaveStandard DIN 49 440DOS20070DOS00268With master-slave moduleWith master-slave module- If the master equipment is switched, the slavesockets are also switched (together, with a shortdelay to the master). This means convenientswitching on and off of several hard to access devices.Switching thresholds can be set from outsidevia potentiometer.- Note:- The master equipment power consumptionmust be continuously above the switching-onthreshold. When switching off the master consumer,the power consumption must fall belowthe switch-off threshold.- 19” installation option(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad ratingMax. 250 Vac/16 ATechnical dataSwitching threshold setting rangeOn: 20 mA - 200 mA (approx. 55 mA deliverystatus)Off: 16 mA - 160 mA (approx. 44 mA deliverystatus)Switching delay: 550 ms +/- 20 %Electronic module: 2-pole switchingSupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP683 9 • 03.314.009.1 1 unit03.314.005.1 1 unit483 5 • •Dimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.36


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® CombiStandard DIN 49 440DOS00325DOS00272DOS00273With master-slaveovervoltage protectionand mains filterWith master-slaveovervoltage protectionand mains filter- Master-slave with overvoltage protection andmains filter- Automatic consumer switching- Combines Master-Slave (page 7.16) and SafetyStandard (page 7.15) functions- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayTechnical dataOvervoltage protection and mains filter:Mains voltage: max. 250 VacNominal current: 16 ARequirements class: D (precision protection inacc. with VDE 0675)Protection level (8/20 μs wave):Max. 10 kAProtection level (1.5/50 μs wave): ‹ 1500 V(L + N against PE)Master-slave function:Switching threshold setting rangeOn: 20 mA - 200 mA (approx. 55 mA deliverystatus)Off: 16 mA - 160 mA (approx. 44 mA deliverystatus)Switching delay: 550 ms +/- 20 %Electronic module: 2-pole switchingSupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP782 9 • 03.320.109.1 1 unit733 9 • 03.320.009.1 1 unit582 5 • • 03.321.105.1 1 unit582 5 • 03.320.105.1 1 unit533 5 • 03.320.005.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.37


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® GST18 Plug System (Wieland) CompactStandard DIN 49 440DOS20060DOS00663DOS20045DOS20046With switchWithout switch- Quick and efficient plug connection system- Plug-in electro-installation in place of conventionalwiring- Speed:- With easy pre-configured element pluggingtogether- Flexibility:- With cable (cable length)- Rational:- Easy exchange of socket strips, withoutextensive cabling- Safety:- Faulty installations are ruled out with plugsystem- Space-saving:- Use of protection and switching functions canbe extended with further cabling without andplug space loss (max. load rating 16 A)Material/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-scheme- VDEColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP583 • 6 • With switch 03.302.206.1 1 unit433 • 3 • With switch 03.302.203.1 1 unit533 7 •383 4 •03.300.207.1 1 unit03.300.204.1 1 unitKnürr DI-STRIP ® Safety Basicwith GST18 plug system- With overvoltage protection- Technical description, see page 2.34DOS20072L S n F1 F2 19” Safe Model Order no. UP433 4 03.316.204.1 1 unitKnürr DI-STRIP ® Safety Standardwith GST18 plug system- With overvoltage (surge) protection, with integratedmains filter and lit switch- Technical description, see page 2.35DOS20073L S n F1 F2 19” Safe Model Order no. UP583 5 03.318.205.1 1 unitKnürr DI-STRIP ® Master Slavewith GST18 plug system- Technical description, see page 2.36DOS00464L S n F1 F2 19” Safe Model Order no. UP533 5 03.314.205.1 1 unit2.38


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Euro Plug System, IEC 320with GST18 plug systemDOS20112DOS20107Input- With 3-way Euro combinations of IEC 320 sockets- Without fusingMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableDimensionsSocket spacing: 24 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CSA NRTL/C- CB-schemeCo l o rHousing: RAL 7035 light grayPlastic parts: RAL 7021 dark grayLoad rating100-240 Vac/10 AApproval symbols for IEC 320 3-way EurocombinationsVDE, UR, CSASupply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP383 6 • 03.600.206.1 1 unitDOS20106Output forfurther cablingKnürr DI-STRIP ® Safety Basic Euro Socket System IEC 320with GST18 plug system- With overvoltage protection- Technical description, see page 2.34DOS20110L S n F1 F2 19” Safe Model Order no. UP483 6 03.616.206.1 1 unitKnürr DI-STRIP ® Safety Standard with GST18 Plug System- With overvoltage (surge) protection withintegrated mains filter- Technical description, see page 2.35DOS20109L S n F1 F2 19” Safe Model Order no. UP483 6 03.618.206.1 1 unitKnürr DI-STRIP ® <strong>Power</strong> Cleanerwith GST18 plug system- Technical description, see page 2.33DOS20108L S n F1 F2 19” Safe Model Order no. UP483 6 03.612.206.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.39


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>3-phase in rack with GST18Strong points1 RequirementConstantly increasing energyrequirements in the rack caused byhigh packing densities (e.g. 1 U PizzaServers, Blade Servers, etc.)2 Solution3-phase distributor with GST18 plugsystem, e.g. 96 A and more withredundant feed1 DOS20147 2 DOS201323 Benefits- Modularity- Plug-in(no wiring required)- Expandability- Cascadability- Easy provision of redundancies/UPSsecured circuits- Combination of DIN Schuko andIEC320, for example- Installation position freelyselectable- Good alternative for 3-phaseDI-STRIP Triple <strong>Power</strong> (see page 156)3 DOS20142 3 DOS20135<strong>Power</strong> Supply Cable, 3-PhaseAccessories for GST 18 plug system- GST 18 socket for connecting GST18i5 distributor Co l o rblock with 3 phasesBlack- 5-pole (L1, L2, L3, N, PE) 250/400 V ~- Cable: HO5VV-F 5G 2.5 mm 2L S n F1 F2 19” Safe Model Order no. UP2000 04.000.048.0 1 unitDOS20104GST18i5 Distributor Block, 3-phase- For individual connection at the customer- Modular plug-in connection- 3 phase distribution on various socket strips- Including mounting panelCo l o rBlackDOS20103L S n F1 F2 19” Safe Model Order no. UP04.000.038.9 1 unit2.40


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong><strong>Power</strong> Supply Cable, 1-PhaseAccessories for GST 18 plug system- Mains plug CEE/VII - GST18 socket (Wieland)Co l o r- Cable - H05VV-F3G 1.5 mm 2 WhiteL S n F1 F2 19” Safe Model Order no. UP2000 04.000.040.0 1 unit5000 04.000.041.0 1 unitDOS00467Connection CableAccessories for GST 18 plug system- GST 18 plugCo l o r- GST 18 socketFor color coding circuits (e.g. UPS)- Cable - H05VV-F3G 1.5 mm 2DOS00469L S n F1 F2 19” Safe Model Order no. UP200 White 04.000.042.0 1 unit200 Black 04.000.042.9 1 unit500 White 04.000.037.0 1 unit500 Black 04.000.037.9 1 unit1000 White 04.000.044.0 1 unit1000 Black 04.000.044.9 1 unit5000 White 04.000.045.0 1 unitDOS20105GST18 Socket Part- With screw terminal for cross-section1.5-2.5 mm 2 with cable strain relief- For individual connection at the customerCo l o rWhiteL S n F1 F2 19” Safe Model Order no. UP04.000.046.0 1 unitDOS00471GST18 Plug Part- With screw terminal for cross-section1.5-2.5 mm 2 with cable strain relief- For individual, further cabling at the customerCo l o rWhiteL S n F1 F2 19” Safe Model Order no. UP04.000.047.0 1 unitDOS004702.41


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Euro Plug System, IEC 320mit WinkelsteckerDOS20062DOS00498- Optionally with lit switch, 2-pole switching- 19” installation option- With Euro combinations of IEC 320 socketsC 13 and C 19- Cable: H05VV-F 3G 1.5 mm 2- Cable: 2.5 m- Without fusingMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableDimensionsHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeCo l o rHousing: RAL 7035 light grayPlastic parts: RAL 7021 dark grayLoad rating250 Vac/10 A, C 13250 Vac/16 A, C 19Approval symbols for IEC 320 3-way EurocombinationsVDE, UR, CSADOS20042Supply schedule1 socket strip2 mounting bracketL S n F1 19” Input values Input plug Outputs Order no. UPC 13 C 19333 6 • 230Vac, 16A Schuko CEE7 6 03.600.006.1 1 unit230Vac, 16A Schuko CEE7 9 03.602.009.1 1 unit483 • 9 • •483 12 • • 230Vac, 10A IEC60320 Sheet E 12 03.600.312.1 1 unit783 18 • 230Vac, 16A IEC60320 Sheet I 15 3 03.600.418.1 1 unit783 18 • 230Vac, 16A IEC60309 1ph/N/PE 6h 15 3 03.600.518.1 1 unitKnürr DI-STRIP ® Euro Plug System, IEC 320Euro input in plug panelDOS00458DOS20041With switch- With fine-wire fuse 10A- Optionally with lit switch, 2-pole switching- 19” installation option- With 3-way Euro combinations of IEC 320socketsMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94),recyclableDimensionsSocket spacing: 24 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CSA NRTL/C- CB-schemeCo l o rHousing: RAL 7035 light grayPlastic parts: RAL 7021 dark grayLoad rating100-240 VacInput: (DC max. 10 A)Output: (DC max. 10 A)Approval symbols for IEC 320 3-way EurocombinationsVDE, UR, CSASupply schedule1 socket strip2 mounting bracketDOS20040Without switchDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundL S n F1 F2 19” Safe Model Order no. UP383 6 • 03.622.006.1 1 unit03.622.009.1 1 unit483 9 • •433 • 6 • With switch 03.624.006.1 1 unitReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.42


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Euro Plug System, IEC 320Euro input on side panelDOS00460DOS00461- With fine-wire fuse 10A- Optionally with lit switch, 2-pole switching- 19” installation option- With 3-way Euro combinations of IEC 320socketsMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94),recyclableDimensionsSocket spacing: 24 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CSA NRTL/C- CB-schemeLoa d rati n g100-240 VacInput: (DC max. 10 A)Output: (DC max. 10 A)Approval symbols for IEC 320 3-way EurocombinationsVDE, UR, CSASupply schedule1 socket strip2 mounting bracketDOS20043With switchCo l o rHousing: RAL 7035 light grayPlastic parts: RAL 7021 dark grayL S n F1 F2 19” Safe Model Order no. UP333 6 • 03.622.706.1 1 unit433 9 • 03.622.709.1 1 unitDOS20044Without switch383 • 6 • With switch 03.624.706.1 1 unit483 • 9 • With switch 03.624.709.1 1 unitKnürr DI-STRIP ® Euro Plug System, IEC 320with cable and right angle plugDOS20102- With thermal overload protection, 10 A (canbe reset)- With lit switch, 1-pole switching- 19” installation option- With 2 5-way Euro combinations of IEC 320 sockets- Cable: H05VV-F 3G 2.5 mm 2- Cable: approx. 5 m- Molded right angle plug, CEE7/VII, optional blue16 A-6h (2P+PE) CEE17 plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94),recyclableDimensionsSocket spacing: 24 mm Height: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeCo l o rHousing: RAL 7035 light grayPlastic parts: RAL 7021 dark grayLoad rating250 Vac/10 AApproval symbols for IEC 320 5-way EurocombinationsUR, CSA, VDESupply schedule1 socket strip2 mounting bracketDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundL S n F1 F2 19” Safe Model Order no. UP483 • 10 • • With switch 03.632.010.1 1 unitReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.43


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Mains cable for Euro socket stripFor DIN 49 440 and French/Belgian standard- Mains plug CEE/VII - Euro socket IEC 320Mains voltage- Cable - H05VV-F 3G 1 mm 2 250 VACNominal current10 ADOS00076L S n F1 F2 19” Safe Model Order no. UP2000 04.000.054.9 1 unit6000 04.000.053.9 1 unitNetzkabel für Kaltgeräte-Steckdosenleiste für Schweizer Standard- Mains plug: Type 12 - Euro socket IEC320Mains voltage- Cable - H05VV-F 3G 1 mm 2 250 VACNominal current10 ADOS00077L S n F1 F2 19” Safe Model Order no. UP2000 04.000.055.9 1 unitMains cable for Euro socket stripFor British standard- Mains plug: Type BS 1363 - Euro socket IEC 320Mains voltage- Cable - H05VV-F 3G 1 mm 2 250 VACNominal current10 ADOS00078L S n F1 F2 19” Safe Model Order no. UP2000 04.000.056.9 1 unitEuro Connection Cable- Mains plug: IEC 320 - Euro socket IEC320- Cable - H05VV-F 3G 1 mm 2- USA: SJT AWG18 with USA approvalMains voltage250 VACNominal current10 ADOS00519L S n F1 F2 19” Safe Model Order no. UP900 EU 04.000.051.9 1 unit900 USA 04.000.052.9 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.44


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>DOS20018DOS20019Knürr DI-STRIP ® ClassicStandard CEE 7-V (UTE) / France- Optionally with lit switch, 2-pole switching- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: Closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 100 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP1783 17 • • 03.400.067.x 1 unit1383 13 • • 03.400.063.x 1 unit983 9 • • 03.400.059.x 1 unit583 5 • • 03.400.055.x 1 unit1733 • 16 • • With switch 03.402.066.x 1 unit1333 • 12 • • With switch 03.402.062.x 1 unit933 • 8 • • With switch 03.402.058.x 1 unit533 • 4 • • With switch 03.402.054.x 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.45


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® CompactStandard CEE 7-V (UTE) / FranceDOS20023DOS20022DOS20025With switchWithout switchWith switch- Optionally with lit switch, 2-pole switching- 19” installation option (with length 483 mm)- 2 versions: Standard side panel or Designside panel- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketsDOS20024Without switchL S n F1 F2 19” Safe Model Order no. UP883 15 • • 03.400.015.x 1 unit732 11 • • 03.400.111.x 1 unit683 11 • • 03.400.011.x 1 unit532 7 • • 03.400.107.x 1 unit483 7 • • • 03.400.007.x 1 unit382 4 • • 03.400.104.x 1 unit333 4 • • 03.400.004.x 1 unit883 • 14 • • With switch 03.402.014.x 1 unit732 • 10 • • With switch 03.402.110.x 1 unit683 • 10 • • With switch 03.402.010.x 1 unit532 • 6 • • With switch 03.402.106.x 1 unit483 • 6 • • • With switch 03.402.006.x 1 unit382 • 3 • • With switch 03.402.103.x 1 unit333 • 3 • • With switch 03.402.003.x 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.46


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Protector FIStandard CEE 7-V (UTE) / FranceDOS20026Protector FIRCCB for user protection- Protection with indirect contact as errorprotection by switching off with inadmissiblehigh contact voltage through contact withelectrical equipment- Protection with direct contact asback-up protection- Residual operating current Ig = 10 mA foralternating and pulsating direct fault current- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 78 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP883 13 • •683 9 • •483 5 • • •03.404.013.1 1 unit03.404.009.1 1 unit03.404.005.1 1 unitKnürr DI-STRIP ® Protector LSStandard CEE 7-V (UTE) / FranceDOS20026Protector LS- Circuit breaker for overload and short circuit- Protects cables and feeds with rapidswitching off with short circuit and defineddelayed cutoff with overload- Circuit breaker: 16 A- Tripping characteristic, type B, 2-pole- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 78 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketsDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundL S n F1 F2 19” Safe Model Order no. UP883 13 • •683 9 • •483 5 • • •03.408.013.1 1 unit03.408.009.1 1 unit03.408.005.1 1 unitReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.47


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Protector FI / LSStandard CEE 7-V (UTE) / FranceDOS 20026Protector FI / LS- RCCB and circuit breaker- Provides a combination of user, overload andshort circuit protection- Residual operating current Ig = 30 mA foralternating and pulsating direct fault current- Circuit breaker: 16 A- Tripping characteristic,type B, 2-pole- 19” installation option(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: Closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 78 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP883 13 • •683 9 • •483 5 • • •03.410.013.1 1 unit03.410.009.1 1 unit03.410.005.1 1 unitKnürr DI-STRIP ® Protector Emergency STOPStandard CEE 7-V (UTE) / FranceDOS20027DOS20028Classic withemergency stop switchCompact withemergency stop switch- With 2-pole emergency stop switch for userprotection- For protecting operating personnel- For manual emergency switching off of theconnected consumers- Phase and neutral conductors are safelyseparated- Switch must be specifically unlocked to restart- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: Classic: 100 mm,Compact: 50 mmHeight: 101 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationsFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting brackets2 19” mounting bracket (additional with19” installation option)L S n F1 F2 19” Safe Model Order no. UP683 10 • • Compact 03.426.010.1 1 unit483 6 • • • Compact 03.426.006.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 pound1333 12 • • Classic 03.426.062.1 1 unit933 8 • • Classic 03.426.058.1 1 unitReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.48


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Protector Emergency Stop FI /LSStandard CEE 7-V (UTE) / FranceDOS20029With emergency Off switchand FI-/ LS circuit breaker- With 2-pole emergency stop switch for userprotection- For protecting operating personnel- For manual emergency switching off of theconnected consumers- Phase and neutral conductors are safelyseparated- Switch must be specifically unlocked to restart- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationsFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing:Compact: 50 mmHeight: 101 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mAdditionally:With 2-pole fault current switchand circuit breakerProvides a combination of user, overloadand short circuit protectionLoad rating100-240Vac/16 ASupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP683 8 • • 03.428.008.1 1 unitKnürr DI-STRIP ® <strong>Power</strong> CleanerStandard CEE 7-V (UTE) / FranceDOS20030With mains filter- High-frequency glitches are generally causedby switching processes in an operation from100 kHz to 5 MHz. This high-frequency rateoverloads the mains frequency and affectsadjacent electronic equipment. The mains filterattenuates this high-frequency rate.- The attenuation behavior is harmonized with thetypical interference spectrum.- The mains filter works in both directions. Thismeans that glitches from the equipment to thesocket strip are also filtered from the mains.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayLoad ratingNominal voltage: max. 250 Vac, 50 HzNominal current: max. 16 ASupply schedule1 socket strip2 mounting bracketsDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Dimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundL S n F1 F2 19” Safe Model Order no. UP883 13 • •683 9 • •483 5 • • •03.412.013.x 1 unit03.412.009.x 1 unit03.412.005.x 1 unitReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.49


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Safety BasicStandard CEE 7-V (UTE) / FranceDOS20031DOS20032- For protecting against transient overvoltagesfrom the mains, which, for example, are causedby switching machines on and off.- With critical overvoltages the mains is separated.- Once the safety arrester has been triggered thegreen function display goes out. The socket stripcan then no longer be used. Send the socket stripto the manufacturer for the safety arrester to bereplaced!The safety effect of the type 3 test category andrequirements category "D" is to protect theequipment, i.e. precision protection.The protection devices of the test and requirementscategories 1 and 2 and B and C must be preconnectedin the building installation to ensureoptimum protection.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeCo l o rFinal digit of order number .1:RAL 7035 light grayTechnical dataTest category: Type 3- In acc. with DIN EN 61643-11Requirements class: D- In acc. with VDE 0675-6Mains voltage: 230 VACNominal current: max. 16 ACut-off discharge current (8/20 μs): 10 kAResponse time: ‹ 25 nsProtection level(with 100 A varistor peak current):- L with respect to N: ‹ 800 V- L/N with respect to PE: ‹ 1500 VSupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP732 10 • •683 10 • •532 6 • •483 6 • • •432 4 • •383 4 • •03.416.110.1 1 unit03.416.010.1 1 unit03.416.106.1 1 unit03.416.006.1 1 unit03.416.104.1 1 unit03.416.004.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.50


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Safety StandardStandard CEE 7-V (UTE) / FranceDOS20033DOS20034With overvoltage protectionand mains filterWith overvoltage protectionand mains filter- The "Safety Standard" models consist of acombined overvoltage protection/mains filterelement.- For protecting against transient overvoltagesfrom the mains, which, for example, are causedby switching machines on and off.- With critical overvoltages the mains is separated.- Once the safety arrester has been triggered thegreen function display goes out. The socket stripcan then no longer be used. Send the socket stripto the manufacturer for the safety arrester to bereplaced!- The safety effect of the type 3 test category andrequirements category "D" is to protect theequipment, i.e. precision protection.The protection devices of the test andrequirements categories 1 and 2 and B and Cmust be preconnected in the buildinginstallation to ensure optimum protection.- High-frequency glitches are generally causedby switching processes in an operation from100 kHz to 5 MHz.- This high-frequency rate overloads the mainsfrequency and affects adjacent electronicequipment. The mains filter attenuates this highfrequencyrate.- The attenuation behavior is harmonized with thetypical interference spectrum.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: HO5VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayTechnical dataMains voltage: 230 VACNominal current: max. 16 ACut-off discharge current (8/20 μs): 10 kAResponse time: ‹ 25 nsProtection level(with 100 A varistor peak current):- L with respect to N: ‹ 800 V- L/N with respect to PE: ‹ 1500 VOvervoltage protectionRequirements class: D- In acc. with VDE 0675-6Mains filter- In acc. with VDE 0565 (EN 60939)Supply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP883 • 13 • • With switch 03.418.013.x 1 unit732 • 9 • • With switch 03.418.109.x 1 unit683 • 9 • • With switch 03.418.009.x 1 unit532 • 5 • • With switch 03.418.105.x 1 unit483 • 5 • • • With switch 03.418.005.x 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.51


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Master-SlaveStandard CEE 7-V (UTE) / FranceDOS20035With master-slave module- If the master equipment is switched, the slavesockets are also switched (together, with a shortdelay to the master). This means convenientswitching on and off of several hard to accessdevices. Switching thresholds can be set fromoutside via potentiometer.- Note:- The master equipment power consumptionmust be continuously above the switching-onthreshold. When switching off the masterconsumer, the power consumption must fallbelow the switch-off threshold.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad ratingMax. 250 Vac/16 ATechnical dataSwitching threshold setting rangeOn: 20 mA - 200 mA (approx. 55 mA deliverystatus)Off: 16 mA - 160 mA (approx. 44 mA deliverystatus)Switching delay: 550 ms +/- 20 %Electronic module: 2-pole switchingDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mSupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP683 9 • •483 5 • • •03.414.009.1 1 unit03.414.005.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.52


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® CombiStandard CEE 7-V (UTE) / FranceDOS20037DOS20036Master-slave, overvoltageprotection and mains filterMaster-slave, overvoltageprotection and mains filter- Master-slave with overvoltage protection andmains filter- Automatic consumer switching- Combines Master-Slave (page 7.32) and SafetyStandard (page 7.31) functions- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayTechnical dataOvervoltage protection and mains filter:Mains voltage: max. 250 VacNominal current: 16 ARequirements class: D (precision protection inacc. with VDE 0675)Protection level (8/20 μs wave):Max. 10 kAProtection level (1.5/50 μs wave): ‹ 1500 V(L + N against PE)Master-slave function:Switching threshold setting rangeOn: 20 mA - 200 mA (approx. 55 mA deliverystatus)Off: 16 mA - 160 mA (approx. 44 mA deliverystatus)Switching delay: 550 ms +/- 20 %Electronic module: 2-pole switchingSupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP782 9 • •733 9 • •582 5 • •533 5 • •03.420.109.1 1 unit03.420.009.1 1 unit03.420.105.1 1 unit03.420.005.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.53


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Compact GST 18 Plug System (Wieland)Standard CEE 7-V (UTE) / FranceDOS20048DOS20047GST 18 with switchGST 18 without switch- Quick and efficient plug connection system- Plug-in electro-installation in place ofconventional wiring- Speed:- With easy pre-configured element pluggingtogether- Flexibility:- With cable (cable length)- Rational:- Easy exchange of socket strips, withoutextensive cabling- Safety:- Faulty installations are ruled out with plugsystem- Space-saving:- Use of protection and switching functions canbe extended with further cabling without andplug space loss (max. load rating 16 A)Material/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Approvals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/16 ASupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP583 • 6 • • With switch 03.402.206.1 1 unit433 • 3 • • With switch 03.402.203.1 1 unit533 7 • • 03.400.207.1 1 unit383 4 • • 03.400.204.1 1 unitDOS20051Knürr DI-STRIP ® Safety Basicwith GST18 plug system / France- With overvoltage (surge) protection- Technical description, see page 2.50L S n F1 F2 19” Safe Model Order no. UP433 4 • 03.416.204.1 1 unitDOS20052Knürr DI-STRIP ® Safety Standardwith GST18 plug system- With overvoltage protection, with integratedmains filter and lit switch- Technical description, see page 2.51L S n F1 F2 19” Safe Model Order no. UP583 5 • 03.418.205.1 1 unitDOS20054Knürr DI-STRIP ® Master Slavewith GST18 plug system- Technical description, see page 2.52L S n F1 F2 19” Safe Model Order no. UP533 5 • 03.414.205.1 1 unit2.54


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® ClassicStandard CH SEV 1011DOS00717DOS00664Classic with switch- With/without switch, socket spacing, 100 mm- Optionally with lit switch, 2-pole switching- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 100 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayLoad rating100-240 Vac/10 ASupply schedule1 socket strip2 mounting bracketsDOS00665Classic without switch L S n F1 F2 19” Safe Model Order no. UP1783 17 • 03.700.067.x 1 unit1383 13 • 03.700.063.x 1 unit983 9 • 03.700.059.x 1 unit583 5 • 03.700.055.x 1 unit1733 • 16 • With switch 03.702.066.x 1 unit1333 • 12 • With switch 03.702.062.x 1 unit933 • 8 • With switch 03.702.058.x 1 unit533 • 4 • With switch 03.702.054.x 1 unit2.55


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® CompactStandard CH SEV 1011DOS20074- Optionally with lit switch, 2-pole switching- 19” installation option (with length 483 mm)- 2 models, standard side or design side- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded plugApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeDOS00666DOS20038Material/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/10 ASupply schedule1 socket strip2 mounting bracketsDOS20039DOS00667L S n F1 F2 19” Safe Model Order no. UP883 15 • 03.700.015.1 1 unit732 11 • 03.700.111.1 1 unit683 11 • 03.700.011.1 1 unit532 7 • 03.700.107.1 1 unit483 7 • • 03.700.007.1 1 unit382 4 • 03.700.104.1 1 unit333 4 • 03.700.004.1 1 unitWith switch 03.702.110.1 1 unit732 • 10 •683 • 10 • With switch 03.702.010.1 1 unit532 • 6 • With switch 03.702.106.1 1 unit483 • 6 • • With switch 03.702.006.1 1 unit382 • 3 • With switch 03.702.103.1 1 unit333 • 3 • With switch 03.702.003.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.56


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Protector FI/LSStandard CH SEV 1011DOS00719DOS00668Protector FI / LS- RCCB and circuit breaker- Provides a combination of user, overload andshort circuit protection- Residual operating current Ig = 30 mA foralternating and pulsating direct fault current- Circuit breaker: 10 A- Tripping characteristic, type B, 2-pole- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 78 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayLoad rating100-240 Vac/10 ASupply schedule1 socket strip2 mounting bracketsL S n F1 F2 19” Safe Model Order no. UP683 9 • 03.710.009.1 1 unit03.710.005.1 1 unit483 5 • •Knürr DI-STRIP ® Safety StandardStandard CH SEV 1011DOS00720DOS00669With overvoltageprotection and mains filter- With overvoltage protection and integratedmains filter- With lit switch, 2-pole switching- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Cable 2.5 mmApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayPlastic parts: RAL 7035 light grayDescription and technical data(See page 165)Nominal current: 10 ASupply schedule1 socket strip2 mounting brackets2 19” mounting brackets (additional with19” installation option)L S n F1 F2 19” Safe Model Order no. UP683 • 9 • With switch 03.718.009.1 1 unit483 • 5 • • With switch 03.718.005.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.57


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Inline Metering System (IMS) –Optimum upgrade solution forexisting installationsMonitoring is already part of the everydayroutine in most data centers when it comesto system availability. For this reason youdecide with new systems for socket strips/<strong>PDUs</strong> with integrated monitoring (Managed<strong>PDUs</strong> or Adaptive <strong>PDUs</strong>). But what doyou do with existing systems in which socketstrips/<strong>PDUs</strong> are usually installed withoutmeasuring functions?<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong>'s solutionfor this is called IMS (Inline MeteringSystem). These modules allow existingracks with installed basic power distributorsto be upgraded accordingly. As almost allserver racks are supplied with an A anda B-feed,later installation is possiblewithout interruption. The IMS modulescan also be installed space-savingly insideor outside the rack, e.g. in the shelf. TheInline Metering Systems (IMS) are dividedinto three different product groups, withdifferent features.<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> InlineMetering Systems (IMS) benefits:■ Existing rack <strong>PDUs</strong> do not have to beswapped out, as the modules■ All consumers (where possible) can beintegrated into the monitoring system,as numerous plug systems are provided(1ph – 3ph, max. 63A per phase).■ Flexible installation inside or outside therack (e.g. in raised floor).Inline Metering System (IMS)IMS model series overview:Knürr DI-STRIP IMSLiebert MPX IMSKnürr MODULAR IMSFeatures:■ Fast installation and easy data recording with graphic and numericalpower consumption overview; can be retrieved via web interface.■ The power value can be read directly on the rack, as a local display isinstalled in every module.■ An N-conductor overload with 3-phase systems can be prevented, as thephase symmetry is monitored.■ Alarm signal when incidents occur, as the threshold values (phasesymmetry, bottom limit, pre-warning and alarm) can be set flexibly.Features:■ Liebert <strong>Rack</strong> <strong>PDUs</strong> familiar software interface, as the samecommunication card as with Liebert MPX/MPH is used.■ Highest possible safety, security and availability with an operatingtemperature of max. 55°C.■ Extensive measurement functions (power, current, voltage and energy),with higher measurement accuracy of up to +-1%.■ An N-conductor overload with 3-phase systems can be prevented, as theN-conductor current is monitored.■ Easy connection to the network with only 1 IP address of up to 4 LiebertMPX IMS / MPH / MPX .■ External sensors and a display can also be connected.Features:■ Extensive measurement functions (power, current, voltage, energy andpower factor), with higher measurement accuracy of up to 0.17% referringto the end value.■ Very high input currents can be measured (up to 850A per phase viaexternal transducer).■ The modular setup means the solution can be adjusted customer-specific(e.g. up to 4 in-feeds per module with different input plugs or even fixed.■ Up to 75 modules can be controlled via one IP address.■ Saving in external databases possible without additional software.2.58


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>INPUT POWER■ Single-phase or three-phase■ 16A up to max. 63AOUTPUT DISTRIBUTOR■ Single-phase or three-phase■ 16A up to max. 63AMODULARITY■ Depending on the type of communication card,external displays or external sensors1-1 10.3A119.5V 4.32kW 5.17kVA12345MONITORING■ Input levelLOCAL MONITORING■ Display for user (MPX IMS and DI-STRIP IMS)10.3A1-1119.5V 4.32kW 5.17kVA12345REMOTE MONITORING■ Secure web and SNMP interfaceRACK PDU ARRAY■ One IP address, up to 4 rack <strong>PDUs</strong> (MPX IMS)■ Liebert MPX, Liebert MPH and Liebert IMS in the sameprivate network2.59


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong><strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong>IMS – product seriesFeatures Knürr DI-STRIP ® IMS Liebert MPX TM IMS Knürr Modular IMSMeasurement module x x xModularxDisplay Fixed ExternalRemote interface x x xMeasuring at input level x x xMeasurement modules per IP address 1 4 75Max. measurement points per IP address 1 4 300Visualization at PDU level x x xVisualization at rack level x xVisualization at room levelOnly with additional softwareLiebert NformOnly with additional Liebert Nformor Avocent DSViewxMeasurement parameters A A,V,W,kWh A,V,W,VA, Var, kWh, cosphi.Phase asymmetry analysis x x xConnection optionfor external sensorsInput power 1ph + 3ph, max 32A 1ph + 3ph, max 32Axx1ph + 3ph, max 63A(max 4 feeds), max. 3ph 999A (via externaltransducer)Connection option IEC 60309, IEC60320, Schuko IEC 60309 IEC 60309, GST18, fixed connectionProtocols HTTP, SNMP, Syslog HTTP, HTTPs, SNMP, Telnet HTTP, HTTPs, SNMP v3,Storage in external databasewith additional softwareLiebert Nformwith additional software Liebert Nformor Avocent DSViewOracle, MySQL, MSSQLOrder numbers:Order number1 ph. 16 AOrder number1 ph. 32 AOrder number3 ph. 16 AOrder number3 ph. 32 A036072001 MPXIMS-EHBAXS30 030145118036072011 MPXIMS-EHBAXQ30 030145128036072021 MPXIMS-EHBAXT30 030145138036072031 MPXIMS-EHBAXR30 030145148Control unit not required not required 0301451082.60


Easy upgrade from basic powerdistributor to measurementenabledpower distributor<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>2.61


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® IMS16 A, single phase- Quick and efficient plug connection system- Plug-in electro-installation in place ofconventional wiring- Speed with easy preconfigured elementsplugging together- Cable flexibility (cable length)Easy socket strip swap-out, without costlycabling- Faulty installations are ruled out with plugsystem- Space-saving use of protection and switchingfunctions can be extended with further cablingwithout any plug space loss on additional socketstrips (max. load rating 16 A)- With big transparent LCD display- Effective value display of alternating current- LCD display rotation in 90° steps- Display can be switched bright or dark- Load changes signaling- Automatic background light reduction- Meets the highest EMC requirements(interference Criterion A; radiated emission: ClassB)Data interface- The plug strip can be integrated into thenetwork via an RJ45 plug.- The sockets can be accessed directly andremotely with a web browser; extra softwareis not required.- The power values are shown graphically andnumerically in the software. Three thresholdvalues and an unbalanced load warning canbe variably set.- Up to 5 users or administrators can accessthe module password-protected.- The software displays the name and place ofthe PDU; this information can be entered byan administrator.- The user can specify a static IP address oraccess via DHCP. Firmware updates can bemade via a web browser.- Supported protocols: HTTP, SNMP (Traps,SET, GET), SyslogMaterial/finish- Housing: Closed sheet steel extrusion,zinc-passivated, powder-coated fine texture- Plastic parts: Vampamid 6 0024 V0 (UL94),recyclable, colored, fine texturedDimensions- Height: 45.5 mm- Housing width: 44.4 mm (1 U)- Length: 333 mmApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- FFC- GS Certificate- CB-schemeCo l o r- Housing: RAL 7035 light gray- Plastic parts: RAL 7021 dark grayLoad ratingNominal voltage: 230 VAC ± 10%Nominal current: 16 ASupply schedule1 plug adaptor module with ampere meter2 mounting bracketsOperating instructionsHow suppliedFlat-packed kitL Input Output Order no. UP333 GST18 inst. plug GST18 inst. socket 03.607.200.1 1 unitKnürr DI-STRIP ® GST plug system Cable setfor Knürr DI-STRIP ® IMS, single phase- Set consisting of one input and one output cable- Cable - H05VV-F3G 1.5 mm 2DimensionsInput cable:Output cable:Length, 2.5 mLength, 0.5 mApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/ECSupply schedule1 cable setHow suppliedFlat-packed kitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundModel Input Output Order no. UPI/O Set GST18i / Schuko Schuko CEE7/4 - GST18i GST18i - Schuko CEE7/4 03.607.200.2 1 unitI/O Set GST18i / IEC320 16 A IEC60320 Sheet I - GST18i GST18i - IEC60320 C 19 03.607.200.3 1 unitI/O Set GST18i / IEC320 10 A IEC60320 Sheet E - GST18i GST18i - IEC60320 C 13 03.607.200.4 1 unitI/O Set GST18i / IEC320 16 A IEC60309 1ph/N/PE 6h - GST18i GST18i - IEC60309 1ph/N/PE 6h 03.607.200.5 1 unitReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.62


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® IMS32 A single phase; 16 A and 32 A three phase- Modules each have an IEC60309 input andIEC60309 output- With big transparent LCD display- Effective value display of alternating current- LCD display rotation in 90° steps- Display can be switched bright or dark- Load changes signaling- Automatic background light reduction- Meets the highest EMC requirements (interference:Criterion A; radiated emission: Class B)Data interface- The plug strip can be integrated into thenetwork via an RJ45 plug.- The sockets can be accessed directly andremotely with a web browser; extra softwareis not required.- The power values are shown graphically andnumerically in the software. Three thresholdvalues and an unbalanced load warning canbe variably set.- Up to 5 users or administrators can accessthe module password-protected.- The software displays the name and place ofthe PDU; this information can be entered byan administrator.- The user can set a static IP address or accessvia DHCP. Firmware updates can be made viaa web browser.- Supported protocols: HTTP, SNMP (Traps,SET, GET), SyslogMaterial/finish- Housing: closed sheet steel extrusion, zincpassivated,powder-coated texture- Plastic parts: Vampamid 6 0024 V0 (UL94),recyclable, colored, fine texturedDimensions- Height: 45.5 mm- Housing width: 44.4 mm (1 U)- Length: 389 mm- Input cable length, 2.5 m- Output cable length, 0.5 mApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- FFC- GS Certificate- CB-schemeCo l o r- Housing: RAL 7035 light gray- Plastic parts: RAL 7021 dark graySupply schedule1 plug adaptor module with ampere meter2 mounting bracketsOperating instructionsHow suppliedFlat-packed kitModel L Input values Input plug Output socket Order no. UPDI-STRIP RM Inline 1x32A 389 230Vac; 32A IEC60309 1ph/N/PE 6h IEC60309 1ph/N/PE 6h 03.607.201.1 1 unitDI-STRIP RM Inline 3x16A 389 230/400Vac; 16A IEC60309 3ph/N/PE 6h IEC60309 3ph/N/PE 6h 03.607.202.1 1 unitDI-STRIP RM Inline 3x32A 389 230/400Vac; 32A IEC60309 3ph/N/PE 6h IEC60309 3ph/N/PE 6h 03.607.203.1 1 unitLiebert MPX TM IMS- Existing rack <strong>PDUs</strong> do not have to beswapped out, as the modules can beupgraded- All consumers (where possible) can be integratedinto the monitoring system, asnumerous plug systems are provided(1ph - 3ph, max. 32 A per phase)- Flexible installation inside or outside the rack(e.g. in raised floor)- Liebert <strong>Rack</strong> <strong>PDUs</strong> familiar softwareinterface, as the same communication cardas with Liebert MPX/MPH is used- Highest possible safety, security and availabilitywith an operating temperature of max. 55 °C- Extensive measurement functions (power,current, voltage and energy), with highermeasurement accuracy of up to ± 1%- An N-conductor overload with 3-phase systemscan be prevented, as the N-conductor current ismonitored- Easy connection to the network with only 1 IPaddress of up to 4 Liebert MPX IMS / MPH / MPX- External sensors and a display can also beconnected.Technical dataInterfaces:- RJ-45 LAN port (10/100 MBit) – for connectingto the local network (LAN) via an Ethernetcable (not included).- Expansion/administration port for: - localconfiguration using a computer/laptop, forsetting up a link-up of several <strong>PDUs</strong>- Display port for connecting the RPC BDM(display module)- External sensor port for connecting optionalsensorsSupported technologies:- Web support, provides Liebert MPX networkmanagement and control. Authorized userscan view status information via their network.- SNMP support, provides Liebert MPX SNMPmanagement.- Easy integration into Liebert Nform, AvocentDSView3 and NagiosMaterial/finish- Housing: Aluminum- Cover: Sheet steel2.63


<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Dimensions- Height: 81 mm- Width: 75 mm- Length: 266 mm- Input cable length, 3 m- Output cable length, 0.5 mApprovals- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- BV GSCo l o r- Housing: Aluminum/RAL 7021 dark graySupply schedule1 MPXIMS Module / power supplyHow suppliedFlat-packed kitModel L Input values Input plug Output socket Order no. UPLiebert MPX TM IMS 1x16A 266 230Vac; 16A IEC60309 1ph/N/PE 6h IEC60309 1ph/N/PE 6h MPXIMS-EHBAXS30 1 unitLiebert MPX TM IMS 1x32A 266 230Vac; 32A IEC60309 1ph/N/PE 6h IEC60309 1ph/N/PE 6h MPXIMS-EHBAXQ30 1 unitLiebert MPX TM IMS 3x16A 266 230/400Vac; 16A IEC60309 1ph/N/PE 6h IEC60309 1ph/N/PE 6h MPXIMS-EHBAXT30 1 unitLiebert MPX TM IMS 3x32A 266 230/400Vac; 32A IEC60309 1ph/N/PE 6h IEC60309 1ph/N/PE 6h MPXIMS-EHBAXR30 1 unitKnürr Modular IMS- Existing rack <strong>PDUs</strong> do not have to beswapped out, as the modules can beupgraded- All consumers (where possible) can be integratedinto the monitoring system, asnumerous plug systems are provided(1ph - 3ph, max. 63 A per phase)- Flexible installation inside or outside the rack(e.g. in raised floor)- Extensive measurement functions (power,current, voltage, energy and power factor), withhigher measurement accuracy of up to 0.17%referring to the end value.- Very high input currents can be measured (up to999A per phase via external transducer)- The modular setup means the solution can beadjusted customer-specific (e.g. up to 4 in-feedsper module with different input plugs or evenfixed feed are possible)- Up to 75 modules can be controlled via one IPaddress- Saving in external databases possible without additionalsoftwareTechnical data- The measurement modules can only beoperated with a control unit- Max. 75 measurement modules can beconnected to a control unit- 2 RJ 45 LAN ports 10/100MBit for connectingto local network (on the control unit)- Visualization of all connectedmeasurement modules via WEB- Status information can be viewed via WEB- Protocols: HTTP, HTTPs, SNMPv3- Storage in external database possible(Oracle, MySQL, MSSQL)- Integration into building systems alsopossible via potential-free contacts- Temperature sensors can be connectedDimensions- Length/depth (control unit): 600 mm- Length/depth (modules): 400 mm- Width: 483 mm (19”)- Height: 88.8 mm (2 U)- <strong>Power</strong> supply cable: Length, 2 mOutput: Input socket fixed on deviceApprovals/certificates- CE Symbol in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- FFC- GS Certificate- CB-schemeCo l o r- RAL 7021 dark graySupply scheduleMeasurement modules, control unitHow suppliedFlat-packed kitModel L Input values Input plug Output socket Order no. UPKnürr Modular IMS 1x16A 2x 230Vac; 16A 2x IEC60309 1ph/N/PE 6h 2x IEC60309 1ph/N/PE 6h 03.014.511.8 1 unitKnürr Modular IMS 1x32A 2x 230Vac; 32A 2x IEC60309 1ph/N/PE 6h 2x IEC60309 1ph/N/PE 6h 03.014.512.8 1 unitKnürr Modular IMS 3x16A 2x 230/400Vac; 16A 2x IEC60309 1ph/N/PE 6h 2x IEC60309 1ph/N/PE 6h 03.014.513.8 1 unitKnürr Modular IMS 3x32A 2x 230/400Vac; 32A 2x IEC60309 1ph/N/PE 6h 2x IEC60309 1ph/N/PE 6h 03.014.514.8 1 unitKnürr Modular Control Unit 03.014.510.8 1 unit2.64

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!