11.02.2015 Views

Eaton 9130 UPS

Eaton 9130 UPS

Eaton 9130 UPS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Powerware series<br />

<strong>Eaton</strong> <strong>9130</strong> <strong>UPS</strong><br />

Product snapshot<br />

Product rating: 700 to 6000 VA<br />

Voltage: 220-240 V<br />

Frequency: 50/60 Hz<br />

(auto-sensing)<br />

Configuration: Rackmount or tower<br />

Advanced power protection for:<br />

• IT and networking environments<br />

• Servers, networking gear<br />

• Telecommunications, VoIP, security systems<br />

• Medical systems<br />

• Diagnostics and medical screening<br />

• Patient record archives<br />

• Manufacturing systems<br />

• Chip fabrication<br />

• Pharmaceutical production<br />

• Chemical processing<br />

Features<br />

• Protects against downtime, data loss and process interruption<br />

by providing continuous, clean power<br />

• Offers premium performance with a 0.9 power factor and<br />

>95 percent efficiency<br />

• Increases battery service life and system uptime with-<br />

ABM battery charging technology<br />

• Enables prolonged runtime of essential equipment during<br />

power outages by allowing for orderly, remote shutdown<br />

of non-critical systems or processes by Load Segment<br />

Control<br />

• Provides installation flexibility with a choice of rack or<br />

tower designs, both conserving valuable space<br />

• Enhanced monitoring and configuration capability through<br />

easily navigated multilingual graphical display<br />

The <strong>Eaton</strong> ® <strong>9130</strong> <strong>UPS</strong>, Powerware<br />

® series, resolves utility<br />

power problems and delivers<br />

superior power protection for<br />

IT and networking equipment,<br />

medical systems, manufacturing<br />

process control—or anywhere<br />

critical equipment and<br />

applications require clean,<br />

continuous power.<br />

Double-conversion<br />

design for superior<br />

power protection<br />

The <strong>9130</strong> is constantly monitoring<br />

power conditions—<br />

regulating both voltage and<br />

frequency. Even when presented<br />

with the most severe<br />

power problems, this <strong>UPS</strong>’s<br />

output remains within three<br />

percent of nominal voltage.<br />

With a wide input voltage range,<br />

the <strong>9130</strong> does not depend<br />

on batteries to smooth out<br />

minor power fluctuations. Batteries<br />

are conserved for those<br />

times when utility power is<br />

highly unstable or completely<br />

out. If an outage occurs, the<br />

<strong>9130</strong> transfers to battery with<br />

zero interruption in power,<br />

making this an ideal <strong>UPS</strong> for<br />

sensitive and critical equipment.<br />

More real power for less<br />

cost in less space<br />

More real power. High 0.9<br />

output power factor enables<br />

the <strong>9130</strong> to provide its full<br />

power capability to modern<br />

IT equipment that may have<br />

a wide range of leading and<br />

lagging power factors. With a<br />

0.99 input power factor, this<br />

<strong>UPS</strong> avoids the disturbances<br />

that some energy converters<br />

tend to cause.<br />

High efficiency. The more<br />

efficient the <strong>UPS</strong>, the lower<br />

your utility and cooling bills.<br />

When power conditions are<br />

within acceptable limits, the<br />

<strong>9130</strong> can operate in a highefficiency<br />

mode providing 95<br />

percent or higher efficiency.


One platform, two form factors, dozens of choices. Up to 3000<br />

VA of <strong>UPS</strong> power is packed into only 2U of rack space. The<br />

tower option is about the size of a modern, compact PC.<br />

ABM technology<br />

Maximum availability for critical systems<br />

Stronger, longer battery life. <strong>Eaton</strong> Advanced Battery Management<br />

(ABM) technology uses sophisticated sensing circuitry<br />

and an innovative three-stage charging technique, that constantly<br />

monitors the battery charging status, and as a result<br />

only recharges when necessary, so ultimately the battery experiences<br />

less corrosion and battery service life is prolonged<br />

by up to 50%.<br />

The <strong>9130</strong> provides up to 60 days’ notice of the end of useful<br />

battery service life. You have ample time to hot-swap batteries<br />

without ever having to shut down connected equipment.<br />

Battery runtime for minutes or hours. During a power outage,<br />

internal batteries in the <strong>9130</strong> keep loads running long enough<br />

to gracefully shut down systems. Add more runtime at any<br />

time, with up to four external hot-swappable battery modules<br />

to run systems for hours if necessary.<br />

Maximum battery runtime for critical equipments. Using Load<br />

Segment Control, you can manage scheduled shutdowns and<br />

sequential startups of protected loads. During a power outage,<br />

you could shut down power to non-critical devices, thereby<br />

extending battery backup time available for critical devices.<br />

You can also use this feature to remotely re-boot locked-up<br />

equipment.<br />

Load segments<br />

Visibility, control and management from anywhere<br />

Continous monitoring for premium availability. The <strong>9130</strong><br />

continually monitors voltage, temperature, internal element<br />

functions, battery health, battery state-of-charge and runtime<br />

remaining. If the <strong>UPS</strong> detects a potential problem with any<br />

of these measures, it sends alarms or takes corrective action,<br />

with no interruption in power. At the end of an alarm condition,<br />

the <strong>9130</strong> automatically reverts from bypass to normal<br />

operation.<br />

Local <strong>UPS</strong> status at a glance. An on-site user can configure<br />

and monitor many features of the <strong>9130</strong> using a large, bright,<br />

backlit display with easy navigation—available in multiple languages.<br />

LEDs provide at-a-glance insight into system status.<br />

Multilingual LCD<br />

Internal batteries +1 EBM +2 EBMs +3 EBMs +4 EBMs<br />

BATTERY RUNTIMES* 75% Load 50% Load 75% Load 50% Load 75% Load 50% Load 75% Load 50% Load 75% Load 50% Load<br />

Rack models<br />

<strong>9130</strong>-1000 VA, 2U 13 22 55 82 103 186 151 250 223 312<br />

<strong>9130</strong>-1500 VA, 2U 11 18 47 81 83 143 126 208 195 262<br />

<strong>9130</strong>-2000 VA, 2U 13 24 63 95 118 190 170 242 221 345<br />

<strong>9130</strong>-3000 VA, 2U 8 14 34 62 70 92 96 156 130 211<br />

Tower models<br />

<strong>9130</strong>-700 VA 12 19 N/A N/A N/A N/A N/A N/A N/A N/A<br />

<strong>9130</strong>-1000 VA 13 22 55 82 103 186 151 250 223 312<br />

<strong>9130</strong>-1500 VA 11 18 47 81 83 143 126 208 195 262<br />

<strong>9130</strong>-2000 VA 21 34 81 130 145 198 184 293 248 431<br />

<strong>9130</strong>-3000 VA 12 20 49 79 90 143 134 180 165 240<br />

<strong>9130</strong>-5000 VA 20 34 81 136 153 232 217 328 273 477<br />

<strong>9130</strong>-6000 VA 16 27 66 107 120 194 178 267 231 372<br />

* Runtimes are shown at a 0.7 power factor. Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.<br />

2 EATON CORPORATION <strong>Eaton</strong> <strong>9130</strong> <strong>UPS</strong>


Remote monitoring. The <strong>9130</strong> comes complete with the <strong>Eaton</strong><br />

Software Suite CD including SNMP-compatible power management<br />

software providing control and visibility over all your<br />

<strong>UPS</strong> systems. For example, you can establish a prioritized<br />

shutdown of network devices and client/server applications,<br />

test all networked <strong>UPS</strong> systems from one node, and stay<br />

informed of power problems by email.<br />

Choice of connectivity options. Connectivity options are available<br />

for almost any networking environment. The standard<br />

unit comes with USB and RS-232 serial communication ports.<br />

You can customize your <strong>UPS</strong> by adding communication cards<br />

options that will allow to:<br />

• Integrate the <strong>UPS</strong> to SNMP based Network Management<br />

Systems with a Web/SNMP card and manage it through<br />

standard web browsers<br />

• Monitor and shut down multiple servers with different<br />

operating systems<br />

• Send relay-contact alarm notifications to remote security<br />

systems<br />

Remote Monitoring - IPM<br />

Complementary options<br />

You can complement your <strong>9130</strong> with several options, among<br />

which:<br />

• A maintenance bypass for easy replacement of the <strong>UPS</strong><br />

without powering down critical systems<br />

• Power distribution units streamline the distribution of<br />

power throughout a data center, rack or enclosure<br />

Description<br />

Part Number<br />

Rating<br />

Dimensions<br />

(VA/Watts)<br />

Input connection Output recetacles<br />

H x W x D, mm<br />

Weight, kg<br />

Tower Models 230V, 50/60Hz<br />

<strong>9130</strong>-700i 103006433-6591 700/630 C14 (6) C13 230 x 160 x 350 12.2<br />

<strong>9130</strong>-1000i 103006434-6591 1000/900 C14 (6) C13 230 x 160 x 380 14.5<br />

<strong>9130</strong>-1500i 103006435-6591 1500/1350 C14 (6) C13 230 x 160 x 430 19.0<br />

<strong>9130</strong>-2000i 103006436-6591 2000/1800 C14 (8) C13, (1) C19 325 x 214 x 410 34.5<br />

<strong>9130</strong>-3000i 103006437-6591 3000/2700 C20 (8) C13, (1) C19 325 x 214 x 410 34.5<br />

<strong>9130</strong>-5000i 103007841-6591 5000/4500 Hardwire Hardwire 574 x 244 x 542 75.5<br />

<strong>9130</strong>-6000i 103007842-6591 6000/5400 Hardwire Hardwire 574 x 244 x 542 75.5<br />

Tower Models 120V, 50/60Hz<br />

<strong>9130</strong>-700L 103006426-6591 700/630 5-15P (6) 5-15R 230 x 160 x 350 12.2<br />

<strong>9130</strong>-1000L 103006427-6591 1000/900 5-15P (6) 5-15R 230 x 160 x 380 14.5<br />

<strong>9130</strong>-1500L 103006428-6591 1500/1350 5-15P (6) 5-15R 230 x 160 x 430 19.0<br />

<strong>9130</strong>-2000L 103006429-6591 2000/1800 5-20P (1) L5-20R, (4) 5-20R 325 x 214 x 410 34.5<br />

<strong>9130</strong>-3000L 103006430-6591 3000/2700 L5-30P (4) 5-20R, (1) L5-30R 325 x 214 x 410 34.5<br />

Tower Extended Battery Modules<br />

<strong>9130</strong> EBM 36 (1kVA) 103006438-6591 NA NA NA 230 x 160 x 380 18.5<br />

<strong>9130</strong> EBM 48 (1.5kVA) 103006439-6591 NA NA NA 230 x 160 x 430 24.3<br />

<strong>9130</strong> EBM 96 (2/3kVA) 103006440-6591 NA NA NA 325 x 214 x 410 50.0<br />

<strong>9130</strong> ebm 240 (5/6kVA) 103007843-6591 NA NA NA 574 x 244 x 542 111.0<br />

Rack Models 230V, 50/60Hz<br />

<strong>9130</strong>-1000iRM 2U 103006455-6591 1000/900 C14 (6) C13 86.5 x 438 x 450 16.0<br />

<strong>9130</strong>-1500iRM 2U 103006456-6591 1500/1350 C14 (6) C13 86.5 x 438 x 450 19.0<br />

<strong>9130</strong>-2000iRM 2U 103006457-6591 2000/1800 C14 (8) C13, (1) C19 86.5 x 438 x 600 29.0<br />

<strong>9130</strong>-3000iRM 2U 103006463-6591 3000/2700 C20 (8) C13, (1) C19 86.5 x 438 x 600 29.5<br />

Rack Models 120V, 50/60Hz<br />

<strong>9130</strong>-1000RM 2U 103006448-6591 1000/900 5-15P (6) 5-15R 87 x 438 x 450 16.0<br />

<strong>9130</strong>-1500RM 2U 103006449-6591 1500/1350 5-15P (6) 5-15R 87 x 438 x 450 19.5<br />

<strong>9130</strong>-2000RM 2U 103006450-6591 2000/1800 5-20P (6) 5-20R, (1) L5-20R 87 x 438 x 600 29.0<br />

<strong>9130</strong>-3000RM 2U 103006452-6591 3000/2700 L5-30P (6) 5-20R, (1) L5-30R 87 x 438 x 600 29.5<br />

Rack Extended Battery Modules<br />

<strong>9130</strong>RM EBM 36 (1kVA) 103006458-6591 NA NA NA 86.5 x 438 x 450 22.1<br />

<strong>9130</strong>RM EBM 48 (1.5kVA) 103006459-6591 NA NA NA 86.5 x 438 x 450 28.1<br />

<strong>9130</strong>RM EBM 72 (2/3kVA) 103006460-6591 NA NA NA 86.5 x 438 x 600 41.1<br />

www.eaton.com/<strong>9130</strong> 3


<strong>Eaton</strong> <strong>9130</strong> <strong>UPS</strong> Product Focus<br />

TECHNICAL SPECIFICATIONS<br />

General<br />

User interface<br />

LEDs<br />

Topology<br />

Diagnostics<br />

<strong>UPS</strong> bypass<br />

Dimensions<br />

Rail kit<br />

Electrical Input<br />

Nominal voltage 120V, 220–240V<br />

Voltage range<br />

120V: 90–138 Vac<br />

230V: 160–276 Vac<br />

Power drawn from <strong>UPS</strong><br />

Dedicated circuit<br />

breaker rating<br />

<strong>UPS</strong> input rating<br />

Graphical LCD with blue backlight and text in<br />

English, French, German, Russian and Spanish<br />

Four status-indicating LEDs<br />

True online, double-conversion<br />

Full system self-test<br />

Automatic bypass<br />

See models table<br />

Included with all rackmount units<br />

700: 3.0A @230V, 5.8A @120V<br />

1000: 4.3A @230V, 8.3A @120V<br />

1500: 6.5A @230V, 12.5A @120V<br />

2000: 8.7A @230V, 16.6A @120V<br />

3000: 13A @230V, 25A @ 120V<br />

5000: 21.7A @230V<br />

6000: 26A @230V<br />

120V:<br />

700–1500 VA: 15A<br />

2000 VA: 20A<br />

2500–3000 VA: 30A<br />

230V:<br />

700–2000 VA: 10A<br />

3000 VA: 16A<br />

5000 VA: 24A<br />

6000 VA: 32A<br />

50/60 Hz<br />

45–65 Hz<br />

Frequency<br />

Frequency range<br />

Electrical Output<br />

Power factor 0.9<br />

On utility voltage ±3% of nominal regulation<br />

On battery voltage ±3% of nominal regulation<br />

Efficiency<br />

>95% in high-efficiency mode; >86% in online mode<br />

Frequency regulation ±3% Hz online<br />

Load crest factor 3 to 1<br />

Battery<br />

Battery type<br />

VRLA 12V/9 Ah (both internal and external)<br />

Battery runtime See runtime table<br />

Battery replacement Hot-swappable internal and external batteries<br />

Start-on-battery Allows start of <strong>UPS</strong> without utility input<br />

Communications<br />

Serial port<br />

USB port<br />

Relay output<br />

Communications slot<br />

Optional communication<br />

cards<br />

Environmental<br />

Safety markings<br />

EMC markings<br />

Audible noise<br />

Ambient operating<br />

temperature<br />

Storage temperature<br />

RS-232 standard, for interface to power management<br />

software<br />

HID standard, for communicating with Windows XP/<br />

Vista<br />

Common alarm standard<br />

Optional communication slots (BD Slot)<br />

SNMP/Web card for direct control and monitoring<br />

in SNMP-based networks, monitoring of <strong>UPS</strong> status<br />

and meters through Web browser interface.<br />

Relay card for integration to industrial environment<br />

and building management systems, remote shutdown<br />

for IBM AS/400 systems<br />

120V: UL, CUL, VCCI<br />

230V: CE, GS<br />

120V: FCC Class B, EN55022 Class B (1.5 kVA and<br />

below); FCC Class A, EN55022 Class A (2.0 kVA<br />

and above)<br />

230V: CE (per IEC/EN62040-2: Emissions, Category<br />

C1; Immunity, Category C2)<br />

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!