HP StorageWorks 1500 cs Modular Smart Array
HP StorageWorks 1500 cs Modular Smart Array
HP StorageWorks 1500 cs Modular Smart Array
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Overview<br />
The <strong>HP</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Array</strong> is a 2Gb Fibre Channel SAN attached 2U controller shelf that connects to both<br />
enterprise-class SCSI and Serial ATA (SATA) disk enclosures. <strong>HP</strong> recommends SCSI drives for intensive heavy I/O requirements while<br />
SATA drives should only be used in archived, reference, or "near on-line" disk-to-disk backup configurations. This combination<br />
provides customers with a low cost, high capacity storage solution.<br />
NOTE: NOTE: NOTE: SCSI hard drive options have a three year warranty and SATA hard drives options have a one year warranty. This solution<br />
has been designed as a hardware foundation for which future solutions can be designed and implemented for investment protection.<br />
The MSA<strong>1500</strong> <strong>cs</strong> with up-to-eight attached SATA enclosures can provide the customer with up to 64 TB* of native capacity. If the<br />
business requires SCSI reliability then attach up-to-four SCSI enclosures for a raw capacity of 16.8 TB. The system supports mixing<br />
SCSI and SATA enclosures.<br />
The MSA<strong>1500</strong> <strong>cs</strong> provides 2 Gb Fibre Channel to the hosts. By utilizing existing SCSI drive enclosures and MSA1000/<strong>1500</strong><br />
controller technology and integrating the use of our lowest cost SATA hard drives and enclosures, the MSA<strong>1500</strong> <strong>cs</strong> lowers the total<br />
cost of ownership and extends the customers hardware investments into the future. With lower cost of ownership, customers can now<br />
take advantage of tiered storage capabilities matching up data with appropriate levels of performance, availability and cost of data<br />
storage. The result is lower overall cost without giving up the needs of business applications.<br />
The MSA<strong>1500</strong> <strong>cs</strong> is a member of the <strong>HP</strong> <strong>StorageWorks</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Array</strong> family, delivering industry-leading technology to meet<br />
today's demanding and growing storage needs. These storage solutions offer the best price performance features for direct attach<br />
environments and entry-level and mid-range SAN environments. Each solution is designed to maximize transfer rates, reduce<br />
management costs, while driving rapid return on investment.<br />
The MSA<strong>1500</strong> <strong>cs</strong> can be remotely managed by using management tools such as <strong>HP</strong> Insight Manager, <strong>Array</strong> Configuration Utility<br />
and the <strong>HP</strong> <strong>StorageWorks</strong> Fabric Switch Management Utility depending on the host's operating system.<br />
*Maximum available storage capacity depends on the RAID level being implemented, and is based on maximum number of LUNs<br />
(32) and maximum LUN size (2 TB).<br />
What's What's New<br />
New<br />
Models Models<br />
Models<br />
Release of the new MSA<strong>1500</strong> SAN Starter Kits designed specifically for <strong>HP</strong>-UX Integrity and PA-RISC server customers.<br />
<strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong><br />
<strong>StorageWorks</strong><br />
<strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong><br />
<strong>Smart</strong><br />
<strong>Array</strong><br />
<strong>Array</strong><br />
MSA<strong>1500</strong> <strong>cs</strong> 2U Fibre Channel SAN Attach Controller Shelf AA986A<br />
MSA<strong>1500</strong> 2U Fibre Channel SAN Attach Controller Shelf, with one MSA20 SATA<br />
drive enclosure<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
<strong>Smart</strong> <strong>Smart</strong> <strong>Smart</strong> Buy Buy Buy Bundle Bundle Bundle MSA<strong>1500</strong> <strong>cs</strong> Controller Shelf and MSA20 Enclosure w/ 12ea. 500 GB SATA HDDs.<br />
NOTE: NOTE: Available in Americas only.<br />
<strong>Smart</strong> <strong>Smart</strong> Buy Buy Bundle Bundle MSA<strong>1500</strong> <strong>cs</strong> Controller Shelf and MSA20 Enclosure w/ 12ea. 750 GB SATA HDDs.<br />
NOTE: NOTE: Available in Americas only.<br />
MSA<strong>1500</strong> 2U Fibre Channel SAN Attach Controller Shelf, with one MSA30 SCSI drive<br />
enclosure<br />
NOTE: NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
AD509A<br />
AJ685A<br />
*NEW*<br />
AJ686A<br />
*NEW*<br />
AD510A<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 1
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Overview<br />
<strong>Smart</strong> <strong>Smart</strong> Buy Buy Bundle Bundle MSA<strong>1500</strong> <strong>cs</strong> Controller Shelf and MSA30 Enclosure w/ 14ea. 300 GB 10K SCSI<br />
HDDs.<br />
NOTE: NOTE: Available in Americas only.<br />
MSA<strong>1500</strong> SAN SCSI G2 Starter Kit<br />
(w/ PCI-E HBAs) (Windows, Linux or NetWare compatible)<br />
NOTE: NOTE: Includes (1) MSA<strong>1500</strong> (1) MSA30 SB SCSI drive enclosure (1) 4/8 Base SAN<br />
Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables.<br />
MSA<strong>1500</strong> SAN SATA Starter G2 Kit<br />
(w/ PCI-E HBAs) (Windows, Linux or NetWare compatible)<br />
NOTE: NOTE: Includes (1) MSA<strong>1500</strong> (1) MSA20 SATA drive enclosure (1) 4/8 Base SAN<br />
Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables.<br />
NOTE: For Americas, Asia Pacific, and Japan only.<br />
MSA<strong>1500</strong> SAN Starter Kit HA G2 Bundle<br />
(w/ PCI-E HBAs) for both SCSI and SATA SAN Starter G2 Kits (Windows, Linux, or<br />
NetWare compatible)<br />
NOTE: NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) 4/8 Base SAN<br />
Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. User will<br />
need to employ either Secure Path (active/passive configurations), QLogic or Emulex<br />
failover, or Windows MPIO for path failover implementation.<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX Dual Controller SCSI SAN Starter Kit<br />
NOTE: NOTE: Includes (2) controllers; (1) MSA30 SB SCSI drive enclosure; (1) FC I/O<br />
module; (2) C-Series 9124 SAN Switches; (8) 4Gb SFP transceivers; (4) <strong>HP</strong> PCI-X 2.0<br />
1Port 4Gb HBAs + cables. User will employ PVlinks for path failover implementation.<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX Dual Controller SATA SAN Starter Kit<br />
NOTE: NOTE: Includes (2) controllers; (1) MSA20 SATA drive enclosure; (1) FC I/O module;<br />
(2) C-Series 9124 SAN Switches; (8) 4Gb SFP transceivers; (4) <strong>HP</strong> PCI-X 2.0 1Port<br />
4Gb HBAs + cables. User will employ PVlinks for path failover implementation.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan only.<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX SCSI SAN Starter Kit (Single Controller)<br />
NOTE: NOTE: Includes (1) controller; (1) MSA30 SB SCSI drive enclosure; (1) C-Series 9124<br />
SAN Switch; (4) 4Gb SFP transceivers; (2) <strong>HP</strong> PCI-X 2.0 1Port 4Gb HBAs + cables.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan only.<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX SATA SAN Starter Kit (Single Controller)<br />
NOTE: NOTE: Includes (1) controller; (1) MSA20 SATA drive enclosure; (1) C-Series 9124<br />
SAN Switch; (4) 4Gb SFP transceivers; (2) <strong>HP</strong> PCI-X 2.0 1Port 4Gb HBAs + cables.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan only.<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX High Availability Kit (only for single controller kits)<br />
NOTE: NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) C-Series 9124 SAN<br />
Switch; (4) 4Gb SFP transceivers; (2) <strong>HP</strong> PCI-X 2.0 1Port 4Gb HBAs + cables. User<br />
will employ PVlinks for path failover implementation.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan only.<br />
AJ689A<br />
*NEW*<br />
AE327B<br />
AE326B<br />
AE328B<br />
AG704A<br />
*NEW*<br />
AG705A<br />
*NEW*<br />
AG706A<br />
*NEW*<br />
AG707A<br />
*NEW*<br />
AG708A<br />
*NEW*<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 2
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Overview<br />
Key Key Features<br />
Features<br />
Dual controllers (optional) can both be configured to provide fail-over protection. Controllers are configured as active<br />
/passive by default and in this manner support only Windows, Linux and NetWare<br />
Dual ACTIVE controllers (active/active) can also be supported individually in Windows, <strong>HP</strong>-UX, Linux, and NetWare<br />
environments.<br />
Ability to mix primary (SCSI) and near-online (SATA) storage behind the same SAN controller for easy to install tiered storage<br />
solutions.<br />
RAID 6 with <strong>HP</strong>'s Advanced Data Guarding technology (RAID ADG)) - Highest level of fault tolerance, allocates two sets of<br />
parity data across drives and allows simultaneous write operations, this level of fault tolerance can withstand two simultaneous<br />
drive failures without downtime or data loss.<br />
2 Gb/1 Gb Fibre connection to host - Supports both 1Gb, 2Gb and 4Gb Fibre Channel fabri<strong>cs</strong> to ensure your investment in<br />
1 Gb infrastructure is protected. Also works with the new 4Gb switches and HBAs at 2Gb speed.<br />
High performance controller(s) built on DAS to SAN (DtS) architecture.<br />
Scalable to eight SATA enclosures for a maximum of 64 TB or four SCSI enclosures for 16.8 TB of storage capacity with four<br />
dual channel SCSI I/O modules.<br />
Hot plug expansion and replacement support - Hot plug expansion and replacement of hard drives and redundant controllers,<br />
for simple, fast installation and maintenance. Fans and power supplies are also hot plug replaceable. Dependent on<br />
individual operating systems.<br />
Key solution certified for backup and restore, file retention and compliance, replication, write once read many for disk, media<br />
and broadcasting, medical, clustering and archiving.<br />
Customer Customer Benefits Benefits<br />
Benefits<br />
Capability of building an enterprise-class SAN with SCSI reliability by attaching up to four MSA30 SCSI-drive enclosures for a<br />
native capacity of 16.8 TB (using 56 - 300 GB SCSI disks)<br />
Low cost, high capacity - For less than $.01 per/MB customers can obtain up to 64 TB* of capacity.<br />
Flexibility - Can choose SATA configuration for secondary storage of data, and/or SCSI configuration for primary storage,<br />
mixing of both technologies behind the same controller is supported but require separate SCSI I/O modules.<br />
Ability to utilize a tiered storage approach as data values decrease, choosing the right disk technology for your data storage.<br />
Investment Protection - the ability to upgrade from the MSA1000 to the MSA<strong>1500</strong> <strong>cs</strong>. Remove the controllers from the<br />
MSA1000 and place them into the controller bays in the MSA<strong>1500</strong> <strong>cs</strong> and upgrade the firmware. (Requires purchase of one<br />
MSA<strong>1500</strong> FC I/O Module per moved controller)<br />
*Maximum available storage capacity depends on the RAID level being implemented, and is based on maximum number of LUNs<br />
(32) and maximum LUN size (2 TB).<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 3
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Family Comparison<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>cs</strong><br />
MSA1000 MSA1000<br />
MSA500<br />
MSA500<br />
NOTE: NOTE: *SOME FEATURES AND FUNCTIONALITIES ARE OPERATING SYSTEM DEPENDENT<br />
Capacity Capacity (Maximum) 16.8 TB SCSI/64 TB SATA 12.6 TB SCSI 4.2 TB SCSI<br />
SCSI SCSI SCSI Interface Interface<br />
Ultra 3, Ultra 320 Ultra 2, Ultra 3, Ultra 320 Ultra 2, Ultra 3, Ultra 320<br />
2nd 2nd controller controller option option<br />
Active/Passive or<br />
Active/Active*<br />
Controller Controller Controller Cache<br />
Cache<br />
(per controller)<br />
256 MB standard<br />
upgradeable to 512 MB<br />
Active/Passive Active/Passive<br />
256 MB standard<br />
upgradeable to 512 MB<br />
256 MB standard<br />
upgradeable to 512 MB<br />
Direct Direct or or SAN SAN<br />
Direct or SAN Attach - Fibre* Direct or SAN Attach - Fibre Direct Attach - SCSI<br />
Maximum Maximum Drives Drives<br />
56 SCSI, 96 SATA or mixed 42 SCSI 14 SCSI<br />
MTBF MTBF (drives) (drives)<br />
1.5M w/ SCSI @ 100%<br />
500,000 w/ SATA @ 20%<br />
Integrated Integrated Integrated Interconnect<br />
Interconnect<br />
Options<br />
Options<br />
Use Use for for Storage Storage<br />
Primary Storage with SCSI,<br />
Secondary with SATA<br />
1.5M w/ SCSI @ 100% 1.5M w/ SCSI @ 100%<br />
No Yes, optional 8-port Switch<br />
or 3-port Hub (some restrictions)<br />
No<br />
Primary Storage with SCSI Primary Storage with SCSI<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 4
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Product Highlights<br />
Product Product Product Technology Technology <strong>Modular</strong> <strong>Modular</strong> Chassis Chassis - The modular design of the MSA<strong>1500</strong> controller shelf can support up to 4 single<br />
channel or 2 dual channel SCSI enclosures, 8 SATA enclosures on 4 dual channel SCSI I/O cards,<br />
redundant controllers, 2 Gb Fibre Channel I/O modules, fans and power supplies.<br />
Scalability Scalability - up to 16.8 TB storage capacity utilizing 56 SCSI hard drives and four MSA30 SCSI<br />
enclosures or up to 64 TB* storage capacity utilizing SATA hard drives and eight MSA20 SATA<br />
enclosures. Larger drives are under investigation for possible future use.<br />
NOTE: NOTE: maximum available storage capacity depends on the RAID level being implemented, and is<br />
based on maximum number of LUNs (32) and maximum LUN size (2 TB)<br />
Performance Performance - The MSA<strong>1500</strong> <strong>cs</strong> and its components have been designed using the latest in standard 2<br />
Gb interconnects and Fibre Channel technology. Performance is rated at a transmission rate of up to<br />
30,000 IOPs from cache and bandwidth of up to 200 MB per second. Performance can be substantially<br />
impacted by number of users and type of application. With dual controller active/active configurations,<br />
performance increase to >41,000 IOP/s from cache and 350MB/s throughput.<br />
Fault Fault Fault Tolerance Tolerance - RAID 6 with <strong>HP</strong>'s Advanced Data Guarding technology (RAID ADG). This is the highest<br />
level of fault tolerance. It allocates two sets of parity data across drives and allows simultaneous write<br />
operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime<br />
or data loss.<br />
DtS DtS Architecture Architecture Architecture - DtS (Direct Attach to SAN) architecture is an exclusive MSA1000 and MSA<strong>1500</strong> <strong>cs</strong><br />
feature that provides a quick and easy way to migrate stored data on SCSI disks protected by most <strong>Smart</strong><br />
<strong>Array</strong> controllers to a MSA1000 or MSA<strong>1500</strong> storage system.<br />
Pre-Failure Pre-Failure Pre-Failure Warranty Warranty - Specific enclosures and hard drives attached to an MSA<strong>1500</strong> and monitored<br />
under Insight Manager are supported by a Pre-Failure (replacement) Warranty.<br />
NOTE: NOTE: Pre-Failure Warranty allows for the replacement of designated SCSI drives in an <strong>HP</strong><br />
<strong>StorageWorks</strong> disk enclosure before they actually fail when using Insight Manger. Some operating<br />
systems may not support all of these features.<br />
Integrated Integrated Configuration Configuration and and Management Management Tools Tools Tools - The MSA<strong>1500</strong> utilizes a standard, integrated set of<br />
management and utility software. Not available with all operating systems.<br />
Hot Hot Plug Plug Expansion Expansion and and and Replacement Replacement Support Support - The MSA<strong>1500</strong> <strong>cs</strong> supports hot plug expansion and<br />
replacement of redundant controllers, fans, power supplies, Serial ATA and SCSI disk enclosures, and<br />
I/O cards for simple, fast installation and maintenance.<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 5
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Software Components<br />
Overview Overview<br />
The MSA<strong>1500</strong> utilizes a set of utility software for storage and RAID management, setup, configuration<br />
and troubleshooting. This reduces the cost of ownership by reducing the training and technical expertise<br />
necessary to install and maintain your <strong>HP</strong> storage solution. Not all operating systems allow use of all of<br />
tools.<br />
<strong>Array</strong> <strong>Array</strong> <strong>Array</strong> Configuration Configuration Utility<br />
Utility<br />
(OS dependent)<br />
Selective Selective Storage<br />
Storage<br />
Presentation Presentation (SSP)<br />
Provides a graphical view of <strong>HP</strong> drive array configurations<br />
Easy to use Wizards for configuration<br />
ACU supports on-line configuration<br />
Web Based ACU supports On-Line, Remote Web Based and Off-line configuration<br />
ACU/CLI available for <strong>HP</strong>-UX customers<br />
Built-in to the controller firmware and controlled via ACU<br />
Allows setting of access rights to the MSA<strong>1500</strong> storage by hosts<br />
Access control can be set up to a logical volume level using the <strong>Array</strong> Controller Utility<br />
Insight Insight Manager Manager Manager<br />
Powerful storage server and server option management tool<br />
Monitor storage from a remote central location<br />
Browser based, provides full access from anywhere on the Intranet, eliminating the need for a<br />
dedicated Insight Manager management console<br />
Availability dependent on operating system<br />
<strong>HP</strong> <strong>StorageWorks</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Array</strong> SMI-S Provider for Windows 2000/Windows Server 2003<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 6
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Compatibility<br />
<strong>HP</strong>'s extensive compatibility testing program assures that your <strong>HP</strong> <strong>StorageWorks</strong> MSA<strong>1500</strong> works with leading servers, operating<br />
systems, and backup applications - and not just those sold by <strong>HP</strong>. The MSA<strong>1500</strong> works seamlessly in many environments, making<br />
them especially suitable if you have a mixed system environment. For the latest list of servers, workstations, operating systems, and<br />
backup software that supports the MSA<strong>1500</strong>, check the <strong>Modular</strong> <strong>Smart</strong> <strong>Array</strong> compatibility pages on our web site at:<br />
http://www.hp.com/go/MSA<strong>1500</strong><strong>cs</strong>.<br />
<strong>HP</strong> <strong>HP</strong> Server Server Compatibility Compatibility The <strong>HP</strong> <strong>StorageWorks</strong> MSA<strong>1500</strong> <strong>cs</strong> supported on the following servers, depending on the various<br />
operating systems:<br />
All ProLiant x86 and x86_64 servers fully supported unless noted below. NOTE: NOTE: NOTE: New models are in test<br />
ProLiant ProLiant x86 x86 servers<br />
servers<br />
BL20p G2, BL30p, BL40p, DL140 G2, DL360, DL360 G2, DL360 G3, DL380, DL380 G2, DL380 G3,<br />
DL560, DL580, DL580 G2, DL740, DL760, DL760 G2, ML370, ML370 G2, ML370 G3, ML530,<br />
ML530 G2, ML570, ML570 G2, ML750<br />
ProLiant ProLiant AMD AMD Opteron Opteron servers<br />
servers<br />
BL25p, BL25p (Dual Core), BL35p, BL35p (Dual Core), BL45p, BL45p (Dual Core), DL145, DL145 G2<br />
(Dual Core), DL385, DL385 (Dual Core), DL585, DL585 G2 (Dual Core) (DL145-G1 not supported in<br />
Boot-From-SAN environment<br />
ProLiant ProLiant INTEL INTEL EM64T EM64T servers<br />
servers<br />
BL20p G3, BL20p G4, BL460c, BL480c, DL360 G4p, DL360 G4, DL360 G5, DL380 G4, DL380 G5,<br />
DL580 G3, DL580 G4, ML350 G4p, ML350 G5, ML370 G4, ML370 G5, ML570 G3, ML570 G4<br />
Integrity Integrity IA64 IA64 (Itanium) (Itanium) servers servers<br />
servers<br />
rx1600 rx1620 rx2600 rx2620 rx4610 rx36xx rx4640 rx5670 rx66xx, rx7620 rx8620 rx8800 rx9610<br />
zx2000 zx6000 Integrity Superdome<br />
NOTE: NOTE: BL60P (FC Mezzanine Card, FC passthru or internal McData/Brocade FC 4Gb Switch Cube)<br />
PA-RISC PA-RISC servers:<br />
servers:<br />
rp24xx, rp34x0, rp4440, rp54xx, rp740x, rp7410, rp7420, rp8400, rp8420, SD16000, SD32-128A,<br />
SD32/64000, C3xxx, B2000, J5xxx, J6000, J7xxx, K-class<br />
Supported Supported Alpha Alpha servers<br />
servers<br />
DS10, DS15, DS20, DS20E, DS25, ES40, ES45, ES47 (PCI-X), ES80 (PCI-X), GS60, GS60E, GS80,<br />
GS140,GS160, GS320, GS1280 (PCI-X)<br />
NOTE: NOTE: NOTE: Certification of new ProLiant & Integrity server models is ongoing. Not all OSes are supported on<br />
all models. Supports most multi-vendor industry standard 32-bit Intel-based (x86) and Opteron servers.<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 7
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Compatibility<br />
OS OS Support Support for<br />
for<br />
Single Single controller controller controller or or dual dual<br />
dual<br />
controller controller configurations<br />
configurations<br />
with with active/passive<br />
active/passive<br />
firmware<br />
firmware<br />
OS OS Support Support for for Dual<br />
Dual<br />
controller controller active/active<br />
active/active<br />
firmware firmware v7.x<br />
v7.x<br />
(requires 2nd controller<br />
and free firmware<br />
download)<br />
<strong>HP</strong>-UX <strong>HP</strong>-UX <strong>HP</strong>-UX support<br />
support<br />
(specific guidelines)<br />
Microsoft Windows Enterprise Edition 2003 (32 & 64-bit) R2<br />
Microsoft Windows Standard Edition 2003 (32 & 64-bit) R2<br />
Microsoft Windows 2000 Server Edition (32 & 64-bit)<br />
Microsoft Windows 2000 Advanced Server (sp4) (32 & 64-bit)<br />
<strong>HP</strong>-UX 11.11 and 11.23 (single controller in homogeneous environments only. For dual controller<br />
heterogeneous support refer to the next section)<br />
Red Hat Linux Enterprise Advanced Server 2.1 and Enterprise Linux 3.0 (32 & 64-bit) & 4.0 (32-bit<br />
& 64-bit )SuSE Linux SLES8 and SLES9 (32 & 64-bit )Netware v5.1 and 6.5.<br />
SCO OpenServer 6.0.0, SCO UnixWare 7.1.3 and UnixWare 7.1.4 (single controller in 2-node<br />
homogeneous environments only).<br />
Please refer to compatibility matrix at http://www.hp.com/go/msa<strong>1500</strong><strong>cs</strong> for complete configuration<br />
support.<br />
Optional controller firmware is available for downloading at no cost from the <strong>HP</strong> MSA<strong>1500</strong> Web Site<br />
that enables both controllers to operate in an active/active mode. The following are the only operating<br />
systems that have been tested and are supported with active/active functionality in a homogeneous<br />
configuration only. All dual active (active/active) controller support is homogeneous.<br />
Microsoft Windows Standard and Enterprise Editions 2003 (32 & 64-bit) R2<br />
Microsoft Windows 2000 Server and Advanced Server (SP4) Editions (32 & 64-bit)<br />
<strong>HP</strong>-UX 11.11, and 11.23<br />
NOTE NOTE: NOTE all MSA<strong>1500</strong> <strong>HP</strong>-UX starter kits ship with active/active firmware pre-installed<br />
Red Hat Linux Enterprise Linux 3.0 (32-bit & 64-bit ) No Red Hat 4 support at this time<br />
SuSE Linux SLES8, SLES9 (32 & 64-bit )<br />
SCO<br />
NOTE: NOTE: <strong>HP</strong> Secure Path is not supported on active/active controller configurations. Industry standard<br />
failover methodology is employed.<br />
The MSA<strong>1500</strong> for <strong>HP</strong>-UX supports dual active/active controller or single controller configurations<br />
(Active/passive configurations are not supported). <strong>HP</strong>-UX single controller support is enabled with the<br />
standard firmware that ships with the MSA<strong>1500</strong><strong>HP</strong>-UX implemented with dual active controllers requires<br />
use of firmware available through a free download off the MSA<strong>1500</strong> web site.<br />
NOTE: NOTE: all MSA<strong>1500</strong> <strong>HP</strong>-UX starter kits ship with active/active firmware pre-installed, which supports<br />
both single controller or active/active controller configurations.<br />
ACU/CLI (Command Line Interface) is used for configuration and Event Monitoring Service (EMS)<br />
for monitoring.<br />
Root/Boot/Dump/Swap/Install is also supported.<br />
PVlinks is supported for multi (HBA) path / single controller (2 HBAs) and dual/active controller<br />
configurations.<br />
Fabric and direct connect are supported<br />
<strong>HP</strong>-UX 11.11 & 11.23, PA-RISC and Itanium<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 8
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Compatibility<br />
Solution<br />
Solution<br />
Offerings/Software<br />
Offerings/Software<br />
Certifications<br />
Certifications<br />
Optional Optional Software<br />
Software<br />
Clustering Clustering<br />
Microsoft Cluster Server<br />
Service Guard for <strong>HP</strong>-UX and Linux<br />
SteelEye LifeKeeper for Linux Certification<br />
Netware Clustering<br />
Polyserve - Matrix Server for Windows<br />
Backup Backup and and Restore Restore<br />
<strong>HP</strong> Data Protector<br />
VERITAS Backup Exec and NetBackup<br />
Legato NetWorker for Windows<br />
Computer Associates BrightStor Enterprise Backup<br />
Medical Medical Imaging<br />
Imaging<br />
Bycast StorageGRID<br />
Management<br />
Management<br />
Replication Replication Replication<br />
<strong>HP</strong> Storage Mirroring for Windows<br />
<strong>HP</strong> Virtual Replicator for Windows.<br />
Other Other<br />
Microsoft Virtual Server<br />
VMware<br />
<strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> Storage<br />
Storage OpenView Storage Mirroring is designed to take small-medium enterprises beyond periodic backup to<br />
Mirroring<br />
Mirroring<br />
provide continuous data protection with minimal data loss and immediate recovery from any disaster or<br />
system outage. Natural and man-made disasters can occur when you least expect it - serving as a<br />
reminders that with less than a moment's notice, volumes of data loss can be lost. To prevent data loss<br />
from failure, error, or disaster, <strong>HP</strong> <strong>StorageWorks</strong> Storage Mirroring software provides replication of your<br />
valuable Windows data, Exchange data, and SQL Data to another server. Proactive replication is a key<br />
strategy that can be coupled with tape backup and snapshot technology for continuous data protection<br />
and point-in-time copies of data. Having replicated data co-located, customers can recover their static<br />
and transactional data in seconds without loss of productivity. Storage Mirroring can also be utilized for<br />
disaster recovery, centralized backup, data distribution/mining, and server/storage migration..<br />
Supports Microsoft Windows 2000/NT/2003servers<br />
One-to-one failover/fail back solution for MS-Exchange, MS-SQL and Oracle providing automatic<br />
failover and near instantaneous access to replicated data or use replicated data or rebuild your<br />
local server.<br />
Server Groups - enables the "grouping" of servers on the management console (GUI) allowing<br />
focus on only those servers under your span of control<br />
Continuous, asynchronous byte-level replication with intelligent data compression captures<br />
changes as they occur, ensures sequence of data mirrored on target, and provides userconfigurable<br />
compression levels to ensure efficient usage of network resources.<br />
One-to-many and many-to-one host configurations allowing multiple production servers to use the<br />
same target server<br />
For more information visit http://h18006.www1.hp.com/products/storage/software/sm/index.html<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 9
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Compatibility<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> utilization utilization of<br />
of <strong>HP</strong> supports additional high availability multi-pathing capabilities within various operating systems and<br />
Industry Industry Industry Standard Standard fail-over<br />
fail-over through third-party vendors, providing continuous data access from <strong>HP</strong>'s RAID MSA<strong>1500</strong> to host servers.<br />
solutions<br />
solutions<br />
Options are available for servers running the Windows, Linux and <strong>HP</strong>-UX operating systems. More<br />
information and the explanation of restrictions are available at<br />
http://h18006.www1.hp.com/products/sanworks/multipathoptions/index.html<br />
Microsoft Windows 2000 and 2003 (32 bit EE and 64 bit EE only)can utilize the <strong>HP</strong> MPIO Basic<br />
Failover v1.3 for MSA <strong>Array</strong>s, a DSM available for free download at the above site.<br />
Linux (and SCO) industry standard failover for the MSA<strong>1500</strong> is available at no charge within the<br />
HBA device driver from QLogic or Emulex.<br />
<strong>HP</strong>-UX utilizes PVLinks<br />
NetWare, OpenVMS, Tru64 UNIX utilize native OS_based failover software<br />
<strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> Secure<br />
Secure <strong>HP</strong> <strong>StorageWorks</strong> Secure Path is a family of high availability multi-pathing software products providing<br />
Path<br />
Path<br />
continuous data access from the <strong>HP</strong> RAID <strong>Array</strong> to host servers running the Windows Server 2003,<br />
(optional, only used with Windows 2000, and Linux operating systems.<br />
active/passive controller Redundant hardware, advanced RAID technology and Secure Path's automated failover capability are<br />
configurations if not used to enhance fault tolerance and availability. Secure Path effectively eliminates controllers, disk drives,<br />
deploying MPIO) interconnect hardware and host bus adapters as single points of failure in the storage subsystem.<br />
The attachment of non-Secure Path (single HBA) servers to a MSA<strong>1500</strong> <strong>cs</strong> with dual controllers that has<br />
servers with Secure Path (dual HBA) attached is supported where the operating system is Windows or<br />
Netware. Users must realize that in event of a controller fail-over (failure of active controller) the single<br />
path servers will lose access to their data on the MSA<strong>1500</strong> <strong>cs</strong>.<br />
NOTE: NOTE: If Secure Path for Linux is used on any node attached to an MSA<strong>1500</strong> <strong>cs</strong>, all nodes must also<br />
have Secure Path installed, regardless of operating systems.<br />
NOTE: NOTE: refer to http://www.hp.com/go/securepath for the latest Secure Path parameters.<br />
Key Key Features Features<br />
Maintains connections to storage<br />
Monitors I/O paths and alerts on significant events<br />
Used in Stand alone Configurations, Cluster Configurations, and SAN<br />
configurations<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> Clustering Clustering Single Single controller controller support support Active/passive Active/passive controllers controllers support support Active/active Active/active controllers controllers support<br />
support<br />
Windows, , Linux, NetWare Windows, Linux, NetWare Windows, <strong>HP</strong>-UX, Linux,<br />
Heterogeneous<br />
(heterogeneous)<br />
(heterogeneous)<br />
<strong>HP</strong>-UX, SCO (homogeneous only)<br />
Netware, SCO, Open VMS and<br />
Tru64 Unix (homogeneous)<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 10
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Compatibility<br />
<strong>HP</strong> <strong>HP</strong> ProLiant ProLiant Cluster<br />
Cluster<br />
HA/F200 HA/F200 for for Entry Entry Level Level<br />
Level<br />
SAN<br />
SAN<br />
In a single controller configuration or when dual controllers are configured as active/passive (standby),<br />
mixing clusters with single nodes is supported. For example you may mix three Microsoft (Windows Server<br />
2003 or Windows 2000) clusters and other individual servers, even doing so in a heterogeneous server<br />
operating system environment. Windows Server 2003 allows a single cluster of up to eight nodes.<br />
To see Cluster Configuration Support Matrices that support the listings on the Microsoft Windows Server<br />
Catalog, refer to:<br />
http://h18004.www1.hp.com/solutions/enterprise/highavailability/answercenter/configuration-all.html<br />
Single-path (single controller, non-Secure Path) NetWare clustering has been successfully tested up to a<br />
12-node cluster. NetWare clusters employing Secure Path (dual controller, dual HBAs) are limited to six<br />
nodes. Multiple NetWare clusters (and single servers) may have concurrent access with no limitation<br />
inherent to the MSA<strong>1500</strong> <strong>cs</strong>.<br />
Up to a 16-node Linux cluster (single controller, non-Secure Path) utilizing SteelEye LifeKeeper for Linux<br />
clustering software has been tested and is supported. Refer to http://www.hp.com/go/securepath for any<br />
restriction with Secure Path.<br />
Up to a 4-node <strong>HP</strong>-UX cluster (dual controller, non-Secure Path) utilizing <strong>HP</strong>-UX Service Guard clustering<br />
software has been tested and is supported. Refer to http://www.hp.com/go/MSA<strong>1500</strong><strong>cs</strong>, the<br />
Compatibility Guide under technical documents under the support section.<br />
The MSA<strong>1500</strong> has the ability to be configured with up to thirty-two LUNs. A configuration of twenty<br />
attached servers has been tested and is supported. More commonly, users have had an average of four<br />
to eight nodes. This can be any combination of hosts or clusters with different operating systems (while<br />
holding fast to the guidelines and limits described in the above paragraphs. Performance within these<br />
guidelines is heavily dependent on the actual number of end users and types of applications being<br />
employed.<br />
For more information, click on the link:<br />
http://h18004.www1.hp.com/products/storageworks/msa<strong>1500</strong><strong>cs</strong>/index.html<br />
The ProLiant Cluster F200 for the Entry Level SAN is designed to assist in simplifying the configuration of<br />
cluster solutions that provide high levels of data and applications availability in the Microsoft Windows<br />
Operating System environment through clustering to provide no-single-point-of-failure. The ProLiant<br />
Cluster F200 for the Entry Level SAN supports a two-node cluster based on Microsoft Windows 2000<br />
Advanced Server and two to eight-nodes cluster based on Microsoft Windows Server 2003 Enterprise<br />
Edition operating system, the <strong>StorageWorks</strong> 1000 <strong>Modular</strong> <strong>Smart</strong> <strong>Array</strong> (MSA1000) and MSA<strong>1500</strong> <strong>cs</strong>, or<br />
Raid <strong>Array</strong> RA4100 and ProLiant Servers. This solution also supports <strong>StorageWorks</strong> Secure Path<br />
management software.<br />
ProLiant Cluster HA/F200 for the Entry Level SAN 364026-B22<br />
ProLiant Cluster HA/F200 for the Entry Level SAN (Japan) 364026-292<br />
<strong>HP</strong> <strong>HP</strong> ProLiant ProLiant Cluster Cluster Starter<br />
Starter The ProLiant Cluster Starter Kit is a ProLiant cluster "How-to-Guide" that includes documentation for<br />
Kit<br />
Kit<br />
ProLiant Clusters that use <strong>StorageWorks</strong> MSA1000, MSA<strong>1500</strong> <strong>cs</strong>, EVA 3000, 4000,5000, 6000 and<br />
8000. The kit provides documentation to set-up a Windows Full-Features MPIO Cluster. The kit also<br />
includes multimedia with animation to illustrate the actual components required to build a Fibre Channel<br />
Cluster and two 30-day trial licenses of OpenView Storage Mirroring.<br />
NOTE: NOTE: This kit does not include Secure Path Software.<br />
<strong>HP</strong> ProLiant Cluster Starter Kit 364023-B21<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 11
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Compatibility<br />
<strong>HP</strong> <strong>HP</strong> ProLiant ProLiant Clusters Clusters for<br />
for<br />
NetWare NetWare<br />
NetWare<br />
<strong>HP</strong> supports a broad range of solutions for NetWare Cluster services including configurations featuring<br />
the MSA<strong>1500</strong> <strong>cs</strong> and optionally with <strong>HP</strong> <strong>StorageWorks</strong> Secure Path. These solutions provide high<br />
availability and maximum resource utilization for NetWare environments from small file sharing<br />
implementations to enterprise business computing. Single-path (single controller, non-Secure Path)<br />
NetWare clusters of up to 12-nodes have been successfully tested. Presently 2-node NetWare clusters<br />
with Secure Path have been tested and approved with larger NetWare cluster testing planned. Multiple<br />
NetWare clusters are allowed.<br />
NOTE: NOTE: NOTE: SCSI Disk Technology Only.<br />
NOTE: NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path for NetWare parameters.<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 12
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configure to Order Program Information<br />
<strong>HP</strong> introduces the Configure to Order program on a limited basis. It is not yet available in all areas. The MSA<strong>1500</strong> and its options<br />
may or may not be factory installed in a rack with add-on controllers, switches, hubs, MSA20 enclosures, MSA30 enclosures, and<br />
hard drives. The MSA<strong>1500</strong> <strong>cs</strong> may be integrated with 64-bit Integrity and PA-RISC servers or ProLiant or as standalone storage.<br />
Configure Configure to to Order Order Products Products Approved Approved for for CTO CTO<br />
Part Part Number<br />
Number<br />
<strong>1500</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Array</strong><br />
NOTE: NOTE: 0D1 will appear after this part number on your sales order when factory<br />
integration is indicated.<br />
AA986A<br />
<strong>HP</strong> MSA1000 Controller 256 cache ALL<br />
NOTE: NOTE: 0D1 will appear after this part number on your sales order when factory<br />
integration is indicated.<br />
218231-B22<br />
256 MB Cache Upgrade<br />
NOTE: NOTE: 0D1 will appear after this part number on your sales order when factory<br />
integration is indicated.<br />
254786-B21<br />
MSA<strong>1500</strong> <strong>cs</strong> Fibre Channel I/O Module<br />
NOTE: NOTE: 0D1 will appear after this part number on your sales order when factory<br />
integration is indicated.<br />
AA987A<br />
MSA<strong>1500</strong> <strong>cs</strong> Dual Channel SCSI I/O Module<br />
NOTE: NOTE: 0D1 will appear after this part number on your sales order when factory<br />
integration is indicated.<br />
AA988A<br />
NO NO CTO CTO CTO Available<br />
Available<br />
(No Kits or Bundles)<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX Dual Controller SCSI SAN Starter Kit AG704A<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX Dual Controller SATA SAN Starter Kit AG705A<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX SCSI SAN Starter Kit (Single Controller) AG706A<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX SATA SAN Starter Kit (Single Controller) AG707A<br />
MSA<strong>1500</strong> <strong>HP</strong>-UX High Availability Kit (only for single controller kits) AG708A<br />
MSA<strong>1500</strong> SAN SCSI G2 Starter Kit (NEW) AE327B<br />
MSA<strong>1500</strong> SAN SATA Starter G2 Kit (NEW) AE326B<br />
MSA<strong>1500</strong> SAN Starter Kit HA G2 Bundle (NEW) AE328B<br />
MSA<strong>1500</strong><strong>cs</strong> 2U Fibre Channel SAN Attach Controller Shelf, with SATA AD509A<br />
MSA<strong>1500</strong><strong>cs</strong> 2U Fibre Channel SAN Attach Controller Shelf, with SCSI AD510A<br />
MSA<strong>1500</strong> <strong>cs</strong> upgrade shelf AD511A<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 13
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Service and Support, <strong>HP</strong> Care Pack, and Warranty Information<br />
Warranty Warranty<br />
Three-year Limited Warranty for MSA<strong>1500</strong>, Fibre Channel Cables and SFP Transceivers<br />
3 years parts exchange<br />
1 year labour<br />
1 year on-site<br />
Next business day response<br />
Warranty Warranty Upgrade Upgrade<br />
Upgrade<br />
Options<br />
Options<br />
Options for the MSA<strong>1500</strong> carry their own warranty. Refer to <strong>HP</strong>'s Limited Warranty Statement for more<br />
information.<br />
The MSA<strong>1500</strong> has been designed with customer self repairable parts to minimize repair time and<br />
provide greater flexibility in performing defective parts replacement. Please refer to <strong>HP</strong>'s Limited Warranty<br />
Statement for further details:<br />
http://h18006.www1.hp.com/products/storageworks/warranty.html<br />
Products included in various Kits carry their own individual warranties.<br />
NOTE: NOTE: The warranty of the hard drive options purchased with the MSA<strong>1500</strong> <strong>cs</strong> product is different for<br />
SCSI hard drives versus SATA hard drives. SCSI hard drive options have a three year warranty and SATA<br />
hard drives options have a one year warranty.<br />
Reference <strong>HP</strong>'s communication for further details: http://www.hp.com go to search, enter CN0089W<br />
Response - Upgrade on-site response from next business day to same day 4 hours<br />
Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days<br />
Duration - Select duration of coverage for a period of 1, 3, or 5 years<br />
<strong>HP</strong> <strong>HP</strong> Care Care Pack Pack Pack Information Information <strong>HP</strong> Care Pack is defined as an upgrade to the product warranty attribute, available for a specific<br />
duration and hours of coverage.<br />
<strong>HP</strong> Care Pack is not available for less than the product's warranty duration.<br />
<strong>HP</strong> Care Pack is available for sale anytime during the warranty period for most products, but the<br />
commencement date will be the same as the Warranty Start Date (delivery date to end user<br />
customer). Proof of purchase may be required.<br />
<strong>HP</strong> Care Pack services are prepaid.<br />
NOTE: NOTE: NOTE: Refer to Step 6 "Choose <strong>HP</strong> Care Pack Services" in the Configuration Information section below<br />
for all Service, Warranty Plans, Installation and Startup Services available for the MSA<strong>1500</strong><br />
For additional information on Product Services and <strong>HP</strong> Care Pack, as well as orderable part numbers,<br />
please refer to the URL: http://www.hp.com/hps/carepack/.<br />
If you have specific questions about availability or how to obtain services contact your local <strong>HP</strong><br />
representative. Contact information for your local area can be found at:<br />
http://welcome.hp.com/country/us/en/contact_us.html<br />
<strong>HP</strong> <strong>HP</strong> Care Care Pack Pack Services Services Services <strong>HP</strong> Care Pack Services offer upgraded service levels to extend and expand your standard product<br />
warranty with easy-to-buy, easy-to-use support packages that help you make the most of your storage<br />
investments.<br />
http://www.hp.com/hps/storage/ns_san.html#services<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 14
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Service and Support, <strong>HP</strong> Care Pack, and Warranty Information<br />
Software Software Product Product Services Services Product support provides the customer access to <strong>HP</strong>'s experienced technical support<br />
resources, as well as access to <strong>HP</strong>'s Information Services database for support on a variety of multivendor/multiplatform<br />
software products. Product support includes escalation and problem coordination<br />
with the appropriate engineering group. <strong>HP</strong> Services offer a variety of options to allow you to tailor your<br />
product service to meet the needs of your organization. Basic warranty on products can be uplifted from<br />
day one to ensure you receive the service you need when you need it.<br />
Warranty Warranty and and Support Support <strong>HP</strong> warrants only that the software media will be free of physical defects for a period of ninety (90) days<br />
from delivery.<br />
The following services are offered as <strong>HP</strong> Care Pack Services at the time of software product order:<br />
Secure Secure Path Path Software<br />
Software<br />
Services<br />
Services<br />
Hardware Hardware Product<br />
Product<br />
Services<br />
Services<br />
Software Technical Support 24 x 7 (1 and 3 years) is available 24 hours per day, Monday through<br />
Sunday, including holidays (includes phone-in software technical support 24 x 7 and software<br />
product and documentation updates).<br />
Installation Service (software installation) and Installation and Startup Service (software installation,<br />
configuration, startup testing and knowledge transfer).<br />
<strong>HP</strong> Care Pack services must be ordered with the product and are prepaid.<br />
For tailored support contracts based on personalized statement of work contact your local<br />
support centre via http://www.<strong>HP</strong>.com/support.<br />
Software product services included with Secure Path: One year of Software Technical Support 24 x<br />
7 <strong>HP</strong> Care Pack Services (includes phone-in software technical support 24 x 7 and software<br />
product and documentation updates).<br />
<strong>HP</strong> Care Pack services are available to upgrade the one year of Software Technical Support 24 x<br />
7 included with the Secure Path product to 3 full years.<br />
Installation service (software installation).<br />
For additional software product services information for <strong>HP</strong> Care Pack services, as well as orderable part<br />
numbers, please refer to the URLs listed below:<br />
All storage services: http://www.hp.com/hps/storage/.<br />
All <strong>HP</strong> Care Pack Services: http://www.hp.com/hps/carepack/storage/cp_networked.html.<br />
Software Support <strong>HP</strong> Care Pack Services: http://www.hp.com/hps/carepack/software/cp_storage.html.<br />
Installation and Startup Services: http://www.hp.com/hps/storage/ns_implementation.html.<br />
If you have specific service questions contact your local <strong>HP</strong> representative. Contact information for your<br />
local area can be found at: http://welcome.hp.com/country/us/en/contact_us.html<br />
Maintenance releases, bug fixes and software patches are available at:<br />
http://welcome.hp.com/country/us/en/support.html.<br />
Installation services that include basic installation and <strong>Array</strong> Installation and Startup<br />
On-site maintenance (includes warranty support)<br />
Response time upgrades during the warranty period<br />
Post-warranty coverage or warranty extension<br />
RAID setup and performance consulting via statement of work<br />
Migration service consulting via statement of work<br />
Environmental, Mission Critical Services<br />
For product services information for <strong>HP</strong> Care Pack services, as well as orderable part numbers, please<br />
refer to the URLs listed below:<br />
All storage services: http://www.hp.com/hps/storage/.<br />
All <strong>HP</strong> Care Pack Services: http://www.hp.com/hps/carepack/storage/cp_networked.html.<br />
Installation and Startup Services: http://www.hp.com/hps/storage/ns_implementation.html.<br />
If you have specific service questions contact your local <strong>HP</strong> representative. Contact information for your<br />
local area can be found at: http://welcome.hp.com/country/us/en/contact_us.html<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 15
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Service and Support, <strong>HP</strong> Care Pack, and Warranty Information<br />
<strong>Array</strong> <strong>Array</strong> Installation Installation and<br />
and<br />
Startup Startup Services Services<br />
Services<br />
The <strong>HP</strong> Installation and startup for <strong>HP</strong> <strong>StorageWorks</strong> Disk <strong>Array</strong>s service package provides installation<br />
and configuration of <strong>HP</strong> <strong>StorageWorks</strong> Disk <strong>Array</strong> products. Service highlights include:<br />
Installation and Startup provides, installation, LUN Disk Design and configuration of the MSA <strong>1500</strong><br />
which includes<br />
Service Planning<br />
Service Deployment<br />
Installation Verification Testing (IVT) required for this service<br />
Customer Orientation session<br />
Service Deployment includes the deployment of the MSA disc array into a new or pre-existing SAN<br />
which may consist of switch, hub or SCSI bridge technology. Installation includes the<br />
customization of up to four host servers, eight host bus adapters (HBAs) and up to four high<br />
availability software licenses.<br />
SAN SAN SAN Solution Solution Service Service SAN Solution Service covers your entry-level disk array solution with:<br />
Comprehensive SAN implementation strategy and planning<br />
Hardware and software installation and configuration<br />
Integration of the installed disk array in your SAN environment<br />
Firmware verification<br />
SAN testing<br />
Solution handover to your staff<br />
The <strong>Array</strong> Installation and Startup service is a pre-requisite for the SAN Solution Service.<br />
For more information about he SAN solution service, please visit:<br />
http://www.hp.com/hps/storage/ns_san.html<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 16
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Kit Contents<br />
Model Model Name Name<br />
Contents' Contents' Contents' Description Description<br />
Part Part Number<br />
Number<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong><br />
MSA<strong>1500</strong> controller shelf, 1-controller, 1- FC module, 1- SFP transceiver, 1- dual<br />
channel SCSI I/O card, 2- power cables, redundant fans, redundant power supplies,<br />
universal rack-mounting kit, MSA<strong>1500</strong> support CD and documentation, serial cable.<br />
NOTE: NOTE: Fibre Channel cables, disk enclosures and hard drives are ordered separately.<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> with with one<br />
one<br />
SATA SATA drive drive enclosure<br />
enclosure<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> & & MSA20<br />
MSA20<br />
w/ w/ 12 12 500GB 500GB 500GB SATA<br />
SATA<br />
Bundle<br />
Bundle<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> & & MSA20<br />
MSA20<br />
w/ w/ 12 12 750GB 750GB SATA<br />
SATA<br />
Bundle<br />
Bundle<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> with with one<br />
one<br />
SCSI SCSI drive drive enclosure<br />
enclosure<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> & & MSA30<br />
MSA30<br />
w/ w/ w/ 14 14 14 300GB 300GB 10k 10k SCSI SCSI<br />
SCSI<br />
Bundle<br />
Bundle<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> MSA<strong>1500</strong> SAN SAN SCSI SCSI SCSI G2 G2<br />
G2<br />
Starter Starter Kit Kit (NEW)<br />
(NEW)<br />
(w/ PCI-E HBAs)<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> SAN SAN SATA<br />
SATA<br />
Starter Starter Starter G2 G2 Kit Kit Kit (NEW)<br />
(NEW)<br />
(w/ PCI-E HBAs)<br />
1- MSA<strong>1500</strong> controller shelf base configuration, and 1-MSA20 SATA disk enclosure<br />
base configuration.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
MSA<strong>1500</strong> <strong>cs</strong> Controller Shelf and MSA20 Enclosure w/ 12ea. 500 GB SATA HDDs.<br />
NOTE: NOTE: Available in Americas only.<br />
MSA<strong>1500</strong> <strong>cs</strong> Controller Shelf and MSA20 Enclosure w/ 12ea. 750 GB SATA HDDs.<br />
NOTE: NOTE: Available in Americas only.<br />
1- MSA<strong>1500</strong> controller shelf base configuration, and 1-MSA30 single-channel SCSI<br />
disk enclosure base configuration.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
MSA<strong>1500</strong> <strong>cs</strong> Controller Shelf and MSA30 Enclosure w/ 14ea. 300 GB 10K SCSI<br />
HDDs.<br />
NOTE: NOTE: Available in Americas only.<br />
(Windows or Linux compatible)<br />
NOTE: NOTE: NOTE: Includes (1) MSA<strong>1500</strong> (1) MSA30 SCSI drive enclosure (1) 4/8 Base SAN<br />
Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables.<br />
(Windows or Linux compatible)<br />
NOTE: NOTE: Includes (1) MSA<strong>1500</strong> (1) MSA20 SATA drive enclosure (1) 4/8 Base SAN<br />
Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan only.<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> MSA<strong>1500</strong> SAN SAN Starter Starter Kit<br />
Kit (Windows or Linux compatible)<br />
HA HA G2 G2 G2 Bundle Bundle (NEW)<br />
(NEW) NOTE: NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) 4/8 Base SAN<br />
(w/ PCI-E HBAs) Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. User will<br />
for both SCSI and SATA need to employ either Secure Path (active/passive configurations), QLogic failover, or<br />
SAN Starter G2 Kits Windows MPIO for path failover implementation.<br />
MSA<strong>1500</strong><strong>cs</strong> MSA<strong>1500</strong><strong>cs</strong> MSA<strong>1500</strong><strong>cs</strong> <strong>HP</strong>-UX <strong>HP</strong>-UX <strong>HP</strong>-UX Dual Dual<br />
Dual (<strong>HP</strong>-UX compatible)<br />
Controller Controller SCSI SCSI SAN<br />
SAN NOTE: NOTE: Includes (2) controllers; (1) MSA30 SB SCSI drive enclosure; (1) FC I/O<br />
Starter Starter Kit<br />
Kit<br />
module; (2) 9124 SAN Switch (8) 4Gb SFP transceivers (4) <strong>HP</strong> PCI-X 2.0 1Port 4Gb<br />
HBAs + cables. User will employ PVlinks for path failover implementation.<br />
MSA<strong>1500</strong><strong>cs</strong> MSA<strong>1500</strong><strong>cs</strong> <strong>HP</strong>-UX <strong>HP</strong>-UX Dual Dual<br />
Dual<br />
Controller Controller SATA SATA SAN<br />
SAN<br />
Starter Starter Kit<br />
Kit<br />
MSA<strong>1500</strong><strong>cs</strong> MSA<strong>1500</strong><strong>cs</strong> <strong>HP</strong>-UX <strong>HP</strong>-UX SCSI<br />
SCSI<br />
SAN SAN SAN Starter Starter Starter Kit<br />
Kit<br />
MSA<strong>1500</strong><strong>cs</strong> MSA<strong>1500</strong><strong>cs</strong> <strong>HP</strong>-UX <strong>HP</strong>-UX SATA<br />
SATA<br />
SAN SAN SAN Starter Starter Kit<br />
Kit<br />
(<strong>HP</strong>-UX compatible)<br />
NOTE: NOTE: NOTE: Includes (2) controllers; (1) MSA20 SATA drive enclosure; (1) FC I/O module;<br />
(2) 9124 SAN Switch (8) 4Gb SFP transceivers (4) <strong>HP</strong> PCI-X 2.0 1Port 4Gb HBAs +<br />
cables. User will employ PVlinks for path failover implementation.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
(<strong>HP</strong>-UX compatible)<br />
NOTE: NOTE: NOTE: Includes (1) controller; (1) MSA30 SCSI drive enclosure; (1) 9124 SAN Switch<br />
(4) 4Gb SFP transceivers (2) <strong>HP</strong> PCI-X 2.0 1Port 4Gb HBAs + cables.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
(<strong>HP</strong>-UX compatible)<br />
NOTE: NOTE: NOTE: Includes (1) controller; (1) MSA20 SATA drive enclosure; (1) 9124 SAN Switch<br />
(4) 4Gb SFP transceivers (2) <strong>HP</strong> PCI-X 2.0 1Port 4Gb HBAs + cables.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
AA986A<br />
AD509A<br />
AJ685A<br />
*NEW*<br />
AJ686A<br />
*NEW*<br />
AD510A<br />
AJ689A<br />
*NEW*<br />
AE327B<br />
AE326B<br />
AE328B<br />
AG704A<br />
*NEW*<br />
AG705A<br />
*NEW*<br />
AG706A<br />
*NEW*<br />
AG707A<br />
*NEW*<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 17
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Kit Contents<br />
MSA<strong>1500</strong><strong>cs</strong> MSA<strong>1500</strong><strong>cs</strong> <strong>HP</strong>-UX <strong>HP</strong>-UX High<br />
High (<strong>HP</strong>-UX compatible)<br />
Availability Availability Kit Kit<br />
Kit<br />
NOTE: NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) 9124 SAN Switch<br />
(4) 4Gb SFP transceivers (2) <strong>HP</strong> PCI-X 2.0 1Port 4Gb HBAs + cables. User will<br />
employ PVlinks for path failover implementation.<br />
NOTE: NOTE: For Americas, Asia Pacific, and Japan.<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> upgrade<br />
upgrade<br />
shelf<br />
shelf<br />
MSA MSA MSA Controller<br />
Controller<br />
management management cable<br />
cable<br />
MSA<strong>1500</strong> controller shelf, 1- dual channel SCSI I/O card, 2- power cables,<br />
redundant fans, redundant power supplies, universal rack-mounting kit, MSA<strong>1500</strong><br />
support CD and documentation, serial cable.<br />
NOTE: NOTE: This MSA<strong>1500</strong> <strong>cs</strong> upgrade shelf does not include a controller or a Fibre<br />
Channel I/O Module. It is intended for those customers who wish to upgrade from<br />
their MSA1000 to the MSA<strong>1500</strong> <strong>cs</strong>. For each controller added to this shelf, one Fibre<br />
Channel I/O module (PN AA987A) is required.<br />
NOTE: NOTE: When upgrading to the MSA<strong>1500</strong> <strong>cs</strong>, there is no space for the MSA1000<br />
embedded switch or hub.<br />
AG708A<br />
*NEW*<br />
AD511A<br />
One ships standard. Orderable through <strong>HP</strong> Store or Service if original is lost 316131-001<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 18
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
Step Step 1 1 1 - - Base Base Configuration<br />
Configuration<br />
Select Select one: one:<br />
one:<br />
Model Model Name Name<br />
Model Model Description: Description:<br />
Part Part Number<br />
Number<br />
MSA<strong>1500</strong> <strong>cs</strong> MSA<strong>1500</strong> controller shelf, 1-controller, 1- FC module, 1- SFP transceiver, 1- dual<br />
channel SCSI I/O card, 2- power cables, redundant fans, redundant power supplies,<br />
universal rack-mounting kit, MSA<strong>1500</strong> <strong>cs</strong> support CD and documentation, serial<br />
cable.<br />
Step Step 2 2 - - Required Required Options Options (Choose (Choose Serial Serial ATA ATA or or SCSI) SCSI)<br />
SCSI)<br />
AA986A<br />
Select each required option with quantities specified. *NOTE: NOTE: SATA drives are designed for archival or reference data. They should<br />
not be used in a heavy or intense I/O environment. Those situations require the use of enterprise-class SCSI drives.<br />
Description Description with with with Parts Parts Shipped: Shipped:<br />
Quantity Quantity Part Part Number<br />
Number<br />
Dual Channel SCSI I/O Module (1 ships with base unit, 3 more can be added) Up to 4 AA988A<br />
MSA20 - Serial ATA enclosure, SCSI cable, redundant fans and power supplies, power cable Up to 8 335921-B21<br />
<strong>HP</strong> 250GB 1.5G SATA 7.2K 3.5" HDD Up to 12 per<br />
MSA20 enclosure<br />
<strong>HP</strong> 500GB 1.5G SATA 7.2K 3.5" HDD Up to 12 per<br />
MSA20 enclosure<br />
<strong>HP</strong> 750GB 1.5G SATA 7.2K 3.5" HDD Up to 12 per<br />
MSA20 enclosure<br />
MSA30 - Dual Channel SCSI enclosure, SCSI cable, redundant fans and power supplies,<br />
power cable<br />
MSA30 - Single Channel SCSI enclosure, SCSI cable, redundant fans and power supplies,<br />
power cable<br />
<strong>HP</strong> 72GB U320 10K Universal HDD Up to 14 per<br />
MSA30 enclosure<br />
<strong>HP</strong> 146GB U320 10K Universal HDD Up to 14 per<br />
MSA30 enclosure<br />
<strong>HP</strong> 300GB U320 10K Universal HDD Up to 14 per<br />
MSA30 enclosure<br />
<strong>HP</strong> 36GB U320 15K Universal HDD Up to 14 per<br />
MSA30 enclosure<br />
<strong>HP</strong> 72GB U320 15K Universal HDD Up to 14 per<br />
MSA30 enclosure<br />
<strong>HP</strong> 146GB U320 15K Universal HDD Up to 14 per<br />
MSA30 enclosure<br />
<strong>HP</strong> 300GB U320 15K Universal HDD Up to 14 per<br />
MSA30 enclosure<br />
349239-B21<br />
395473-B21<br />
432341-B21<br />
Up to 2 302970-B21<br />
Up to 4 302969-B21<br />
286714-B22<br />
286716-B22<br />
350964-B22<br />
286776-B22<br />
286778-B22<br />
347708-B22<br />
411089-B22<br />
NOTE: NOTE: Larger SATA hard drives are currently in qualification but are not presently supported.<br />
NOTE: NOTE: NOTE: Two SATA disk enclosures can be attached to one SCSI I/O module. Only one SCSI disk enclosure can be attached to a<br />
SCSI I/O module.<br />
NOTE: NOTE: It is recommended that the same hard drive capacity (ex. All 250 GB SATA in SATA enclosure or all 146 GB SCSI in SCSI<br />
enclosure) be installed in a RAID-set.<br />
NOTE: NOTE: All Ultra320 Universal Hard Drives are backward compatible to U2 or U3 speeds.<br />
NOTE: NOTE: NOTE: For complete compatibility information, refer to the Compatibility table located at http://www.hp.com/go/msa<strong>1500</strong><strong>cs</strong><br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 19
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
Must Must choose choose optional optional Power Power Cord Cord for for Non-U.S. Non-U.S. Configurations Configurations<br />
Quantity Quantity Part Part Number<br />
Number<br />
Power Cord, 110/220 VAC, US/Canada/Mexico<br />
NOTE: NOTE: Shipped standard with all units.<br />
2 227099-001<br />
Power Cord, 220/240 VAC, (US/Canada/Mexico) 2 227099-002<br />
Power Cord, (Australia/China/New Zealand) 2 227098-011<br />
Power Cord, (Central Europe) 2 157215-021<br />
Power Cord, (United Kingdom/Hong Kong) 2 157216-031<br />
Power Cord, (Switzerland) 2 157219-111<br />
Power Cord, (Italy) 2 157217-061<br />
Power Cord, (Denmark) 2 157218-081<br />
Power Cord, (Japan) 2 139867-006<br />
Power Cord, (South East Asia/India) 2 157220-AR1<br />
NOTE: NOTE: Redundant configurations require two Host Bus Adapters per server, an additional controller and fibre channel I/O module,<br />
and Secure Path or industry standard MPIO failover software for each server.<br />
Step Step 3 3 – – Choose Choose Redundant Redundant MSA<strong>1500</strong> MSA<strong>1500</strong> System System Options Options<br />
Options<br />
Description Description<br />
Quantity Quantity Part Part Number<br />
Number<br />
MSA Controller<br />
NOTE: NOTE: The MSA<strong>1500</strong> utilizes the MSA1000 controller with specific firmware<br />
256 MB Cache Modules for Controller (one additional for each controller)<br />
NOTE: NOTE: The MSA<strong>1500</strong> and MSA1000 utilize the same Cache Modules<br />
1 218231-B22<br />
2 254786-B21<br />
MSA<strong>1500</strong> Fibre Channel I/O module 1 AA987A<br />
<strong>HP</strong> <strong>StorageWorks</strong> Secure Path (available for active/passive configurations only) or an industry<br />
standard path failover solution such as Windows MPIO or QLogic Failover for Linux<br />
(appropriate for the operating system)<br />
NOTE: NOTE: Redundant configurations require two Host Bus Adapters per server, an additional controller and fibre channel I/O module,<br />
redundant switches and cables, and Secure Path (active passive configuration) software or Industry Standard failover depending on<br />
the operating system for each server.<br />
Step Step 4 4 – – Choose Choose Supported Supported Infrastructure Infrastructure Options<br />
Options<br />
Select each required option with quantities specified.<br />
Description Description with with Parts Parts Parts Shipped: Shipped:<br />
Part Part Number<br />
Number<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 20
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
4 4 Gb Gb Fibre Fibre Channel<br />
Channel 4 Gb SFP SW Transceiver Kit A7446B<br />
Fabric Fabric "B-Series" "B-Series" family family of<br />
of<br />
switches<br />
switches<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/8 Base SAN Switch 8 port 4Gb/s switch with zero e-ports<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/8 SAN Switch 4Gb/s with full fabric<br />
A7984A<br />
A8000A<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/16 SAN Switch A7985A<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/16 SAN Switch Power Pack A7987A<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/32 SAN Switch Power Pack A7394A<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/32 Full SAN Switch A7393A<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/32 Base SAN Switch A7537A<br />
<strong>HP</strong> <strong>StorageWorks</strong> 4/8 4 port upgrade license T4260A<br />
4/64 SAN Switch Power Pack 4/64 SAN Switch with 32 active ports AE496A<br />
4/64 SAN Switch with 64 active ports AG457A<br />
<strong>HP</strong> <strong>StorageWorks</strong> Full Fabric license T4261A<br />
<strong>HP</strong> <strong>StorageWorks</strong> B-Series 8-31 port Power Pack License T3573A<br />
4/64 SAN Switch with 32 active ports AE495A<br />
16 port upgrade license for 4/64 SAN Switch (base model) and Power Pack model T4411A<br />
<strong>StorageWorks</strong> 4/256 SAN Director A7988A<br />
<strong>StorageWorks</strong> 4/256 SAN Director Power Pack A7989A<br />
<strong>HP</strong> <strong>StorageWorks</strong> SAN Director 4/16 Blade A7990A<br />
<strong>HP</strong> <strong>StorageWorks</strong> SAN Director 4/32 Blade A7991A<br />
<strong>HP</strong> <strong>StorageWorks</strong> B-Series MP Router Blade AG461A<br />
Power Pack Software Upgrade Bundle 330882-B21<br />
<strong>StorageWorks</strong> SAN Director Blade AD504A<br />
<strong>HP</strong> <strong>StorageWorks</strong> SAN Director 4/16 Blade A7990A<br />
Brocade 4Gb SAN Switch for <strong>HP</strong> p-Class BladeSystem, Base A7533A<br />
Brocade 4Gb SAN Switch for <strong>HP</strong> p-Class BladeSystem, Full Fabric A7534A<br />
Brocade 4Gb SAN Switch for <strong>HP</strong> p-Class BladeSystem, Power Pack A7535A<br />
Brocade 4/12 SAN Switch (1) 4Gb SAN Switch; 12 ports enabled for any<br />
combination (internal and external); two (2) short wave 4Gb SFPs;<br />
Brocade 4/24 SAN Switch (1) 4Gb SAN Switch; 24 ports enabled (16 internal, 8<br />
external); four (4) short wave 4Gb SFPs;<br />
Brocade 4/24 SAN Switch Power Pack (1) 4Gb SAN Switch; 24 ports enabled (16<br />
internal, 8 external); four (4) short wave 4Gb SFPs;<br />
AE370A<br />
AE372A<br />
AE371A<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 21
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
2 2 & & & 4Gb 4Gb Fibre Fibre Channel<br />
Channel Cisco MDS 9124e 12-port Fabric Switch AG641A<br />
Fabric Fabric "C-Series" "C-Series" "C-Series" family family family of<br />
of Cisco MDS 9124e 24-port Fabric Switch<br />
switches<br />
switches<br />
Cisco MDS 9120 2Gb Fabric Switch w/0 SFPs<br />
AG642A<br />
A7426A<br />
2 2 Gb Gb Fibre Fibre Channel<br />
Channel<br />
HBAs<br />
HBAs<br />
Cisco MDS 9140 2Gb Fabric Switch w/0 SFPs A7427A<br />
Cisco MDS 9124 8-ports Active Fabric Switch w/0 SFPs AG646A<br />
Cisco MDS 9124 16-ports Active Fabric Switch w/0 SFPs AG647A<br />
Cisco MDS 9124 24-ports Active Fabric Switch w/0 SFPs AG648A<br />
Cisco MDS 9513 4Gb Director AE376A<br />
Cisco MDS 9506 4Gb Director w/Supervisor 2 AE388A<br />
Cisco MDS 9020 4Gb Fabric Switch w/0 SFPs AE377A<br />
Cisco MDS 9216i w/0 1Gb Ethernet SFPs AE390A<br />
Cisco MDS 9509 Director w/Supervisor 2 AE389A<br />
FCA2214 2Gb Host Adapter (Linux, NetWare, SCO & 32-bit Windows) 281541-B21<br />
FCA2214DC dual channel 2Gb Host Adapter (Linux, NetWare, SCO & 32-bit<br />
Windows)<br />
321835-B21<br />
Windows 32-bit single channel 2Gb PCI-X (Windows Server 2003, W2K) A7388A<br />
Windows 32-bit dual channel 2Gb PCI-X (Windows Server 2003, W2K) A7387A<br />
Host Adapter for Windows Server 2003 64-bit, Integrity servers, single channel 2 Gb<br />
PCI-X<br />
Host Adapter for Windows Server 2003 64-bit, Integrity servers, dual channel 2 Gb<br />
PCI-X<br />
AB467A<br />
AB466A<br />
Host adapter Q2300 2Gb 64-bit PCI-X for Linux, Integrity servers A7538A<br />
Host adapter 2Gb PCI-X Dual channel for <strong>HP</strong>-UX and Linux, Integrity servers A6826A<br />
<strong>HP</strong>-UX HBA: PCI 2GB Fibre Channel Adapter A6795A<br />
<strong>HP</strong> PCI-X 2-port 2Gb Fibre Channel and 2-port 1Gb Ethernet AB465A<br />
<strong>HP</strong>-UX HBA: PCI-X 2Gb Fibre Channel/1000Base-T A9784A<br />
<strong>HP</strong>-UX HBA: PCI-X 2Gb Fibre Channel/1000Base-SX A9782A<br />
FCA2684 PCI-X Single Channel 2Gb Host Adapter for OpenVMS & Tru64 UNIX<br />
AlphaServers<br />
FCA2684DC PCI-X Dual Channel 2Gb Host Adapter for OpenVMS & Tru64 UNIX<br />
AlphaServers<br />
DS-A5132-AA<br />
DS-A5134-AA<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 22
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
4 4 Gb Gb Fibre Fibre Channel<br />
Channel<br />
HBAs<br />
HBAs<br />
Fibre Fibre Channel Channel Channel cables cables for<br />
for<br />
2 2 Gb Gb Infrastructure<br />
Infrastructure<br />
MSA MSA Controller Controller<br />
Controller<br />
management management cable<br />
cable<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC2142SR HBA 4Gb PCI-e for Windows, Linux A8002A<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC2242SR DC HBA 4Gb PCI-e for Windows, Linux A8003A<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC1142 4Gb PCI-e HBA for Windows, Linux AE311A<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC1242 4Gb PCI-e DC HBA for Windows, Linux AE312A<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC2143 4Gb PCI-X 2.0 HBA for Windows, Linux AD167A<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC2243 4Gb PCI-X 2.0 DC HBA for Windows, Linux AD168A<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC1143 4Gb PCI-X 2.0-to-Fibre Channel Host Bus Adapter for<br />
x86, x64 and ia64 Windows and Linux.<br />
<strong>HP</strong> <strong>StorageWorks</strong> FC1243Dual Channel 4 Gb PCI-X 2.0-to-Fibre Channel Host Bus<br />
Adapter for x86, x64 and ia64 Windows and Linux.<br />
AB429A<br />
AE369A<br />
<strong>HP</strong> PCI-X 2.0 1Port 4Gb Fibre Channel HBA AB378B<br />
<strong>HP</strong> PCI-X 2.0 2Port 4Gb Fibre Channel HBA AB379B<br />
<strong>HP</strong>-UX PCI-X single-channel, 4Gb fibre channel adapter AB378A<br />
<strong>HP</strong>-UX PCI-X dual-port, 4Gb fibre channel adapter AB379A<br />
Use 2 Gb Fibre Channel cables when connecting the MSA Fibre Channel I/O Module<br />
to FCA2101 HBA(s)<br />
2 m LC-LC Multi-Mode Fibre Channel Cable 221692-B21<br />
5 m LC-LC Multi-Mode Fibre Channel Cable 221692-B22<br />
15 m LC-LC Multi-Mode Fibre Channel Cable 221692-B23<br />
30 m LC-LC Multi-Mode Fibre Channel Cable 221692-B26<br />
50 m LC-LC Multi-Mode Fibre Channel Cable 221692-B27<br />
2 m LC-SC Multi-Mode Fibre Channel Cable 221691-B21<br />
5 m LC-SC Multi-Mode Fibre Channel Cable 221691-B22<br />
15 m LC-SC Multi-Mode Fibre Channel Cable 221691-B23<br />
30 m LC-SC Multi-Mode Fibre Channel Cable 221691-B26<br />
50 m LC-SC Multi-Mode Fibre Channel Cable 221691-B27<br />
One ships standard. Orderable through <strong>HP</strong> Store or Service if original is lost 316131-001<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 23
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
Step Step 5 5 – – Choose Choose Rack Rack Rack Options<br />
Options<br />
Select each required option with quantities specified.<br />
10647 (47U) Rack Cabinet - Pallet 245160-B21<br />
10647 (47U) Rack Cabinet - Crated 245160-B23<br />
10622 (22U) Rack Cabinet - Pallet 245163-B21<br />
10622 (22U) Rack Cabinet - Shock Pallet<br />
NOTE: NOTE: NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment<br />
installed.<br />
245163-B22<br />
10622 (22U) Rack Cabinet - Crated 245163-B23<br />
S10614 (14U) Rack Cabinet - Shock Pallet<br />
NOTE: NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment<br />
installed.<br />
292302-B22<br />
10842 (800 mm wide, 42U) Rack Cabinet - Pallet 257415-B21<br />
10842 (800 mm wide, 42U) Rack Cabinet - Shock Pallet<br />
NOTE: NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment<br />
installed.<br />
257415-B22<br />
Rail Kit for mounting in a M-Series rack 313877-B21<br />
<strong>HP</strong> <strong>Modular</strong> Cooling System (WW)<br />
NOTE: NOTE: The purchase of <strong>HP</strong> <strong>Modular</strong> Cooling System includes 10642 G2 rack and<br />
MCS unit attached.<br />
AF098A<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> <strong>cs</strong> <strong>cs</strong> to to PDU PDU 2.5m (8.2') 10A, IEC C 13 to IEC C14 PDU Jumper Cable (1 per pack) 142257-002<br />
3.0m (9.8') 10A, IEC C 13 to IEC C14 PDU Jumper Cable (1 per pack) 142257-003<br />
1.4m (4.5') 10A, IEC C 13 to IEC C14 PDU Jumper Cable (1 per pack) 142257-006<br />
Step Step 6– 6– Choose Choose <strong>HP</strong> <strong>HP</strong> Care Care Pack Pack Services<br />
Services<br />
Support Support Services Services via via <strong>HP</strong><br />
<strong>HP</strong><br />
Authorized Authorized Commercial<br />
Commercial<br />
Resellers Resellers - - Fixed Fixed Care<br />
Care<br />
Packs<br />
Packs<br />
MSA<strong>1500</strong> MSA<strong>1500</strong><br />
MSA<strong>1500</strong> MSA<strong>1500</strong> Kits Kits<br />
Kits<br />
Product Product Skus Skus<br />
AA986A AA986A<br />
AD509A<br />
AD509A<br />
AD510A<br />
AD510A<br />
AE326A<br />
AE326A<br />
AE327A<br />
AE327A<br />
Support Support Description Description Description<br />
Care Care pack pack Product<br />
Product<br />
1 Yr 4hr 24x7/Onsite UA774A/E UC762A/E<br />
1 Yr 4hr 13x5/Onsite UA775A/E UC777A/E<br />
1 Yr 6 hr CTR UA776A/E UC778A/E<br />
3 Yr next Day/Onsite UB950A/E UB153A/E<br />
3 Yr 4hr 13x5 /Onsite UB951A/E UB154A/E<br />
3 Yr 4hr 24x7 /Onsite UB952A/E UB155A/E<br />
3 Yr 6 hr CTR UB953A/E UB156A/E<br />
5 Yr 6hr CTR UC986E<br />
*Hardware Installation U4368A/E UB958A/E<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 24
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
*Installation and Startup UA868A/E UA868A/E<br />
*SERVICES *SERVICES NOTE: NOTE: Hardware Installation is not required on the individual hardware components, when quoting the Installation and<br />
Startup service.<br />
Support Support Services Services via via <strong>HP</strong><br />
<strong>HP</strong><br />
Authorized Authorized Resellers Resellers and<br />
and<br />
<strong>HP</strong> <strong>HP</strong> Direct Direct -Flexible -Flexible Care<br />
Care<br />
Packs<br />
Packs<br />
MSA<strong>1500</strong> MSA<strong>1500</strong><br />
MSA<strong>1500</strong> MSA<strong>1500</strong> Kits Kits<br />
Kits<br />
Product Product Skus Skus<br />
AA986A AA986A<br />
AD509A<br />
AD509A<br />
AD510A<br />
AD510A<br />
AE326A<br />
AE326A<br />
AE327A<br />
AE327A<br />
Support Support Description Description Description Care Care Care pack pack pack Product Product<br />
BAND BAND<br />
BAND<br />
BAND<br />
1 Yr 4hr 13x5 Hardware HA103A1 8PN 8PM<br />
1 Yr 4h 24x7 Hardware HA104A1 8PN 8PM<br />
1 Yr 6 hr CTR HA105A1 8PN 8PM<br />
1 Yr Support Plus HA109A1 8PN 8PM<br />
1 Yr Support Plus 24 HA110A1 8PN 8PM<br />
1 Yr Proactive 24 HA111A1 8PN 8PM<br />
1 Year Critical Services HA112A1 8PN 8PM<br />
3 yr Next Day HA101A3 8PN 8PM<br />
3 Yr 4hr 13x5 Hardware HA103A3 8PN 8PM<br />
3 Yr 4hr 24x7 Hardware HA104A3 8PN 8PM<br />
3YR 6hr CTR HA105A3 8PN 8PM<br />
3Yr Support Plus HA109A3 8PN 8PM<br />
3 Yr Support Plus 24 HA110A3 8PN 8PM<br />
3 Yr Proactive 24 HA111A3 8PN 8PM<br />
3 Year Critical Services HA112A3 8PN 8PM<br />
4 year Next Day HA101A4 8PN 8PM<br />
4 Yr 4hr 13x5 Hardware HA103A4 8PN 8PM<br />
4 Yr 4h 24x7 Hardware HA104A4 8PN 8PM<br />
4 Yr 6 hr CTR HA105A4 8PN 8PM<br />
4 Yr Support Plus HA109A4 8PN 8PM<br />
4 Yr Support Plus HA110A4 8PN 8PM<br />
4 Yr Proactive 24 HA111A4 8PN 8PM<br />
4 Year Critical Services HA112A4 8PN 8PM<br />
5 Year 4hr 13x5 Hardware HA104A5 8PN 8PM<br />
5 Year Support Plus 24 HA110A5 8PN 8PM<br />
Hardware Installation HA113A1 5J0 5FZ<br />
Installation and Startup HA114A1 5J0 5FZ<br />
*SERVICES *SERVICES NOTE: NOTE: Hardware Installation is not required on the individual hardware components, when quoting the Installation and<br />
Startup service.<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 25
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Configuration Information<br />
Additional Additional Product Product Skus<br />
Skus<br />
with with Hardware Hardware Installation<br />
Installation<br />
Services Services - - - (break (break (break fix<br />
fix<br />
services services included included with<br />
with<br />
main main enclosure)<br />
enclosure)<br />
MSA1000 MSA1000 to to MSA<strong>1500</strong><br />
MSA<strong>1500</strong><br />
Upgrade Upgrade Kit Kit<br />
Kit<br />
High High High Availability Availability Upgrade Upgrade Upgrade Kit<br />
Kit<br />
Product Product Skus Skus<br />
AD511A AD511A** AD511A<br />
AE328A AE328A** AE328A<br />
Care Care pack pack Product Product Product<br />
BAND BAND<br />
BAND<br />
BAND<br />
**Hardware Installation HA113A1 564<br />
**SERVICES *SERVICES NOTE: NOTE: Installation only required when these products are added on after initial sales of main enclosure(s)<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 26
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Related Options<br />
Secure Secure Path Path v4.0C v4.0C (SP1)<br />
(SP1) Secure Path v4.0C for Windows Workgroup 1 license 213076-B26<br />
for for Windows Windows Workgroup<br />
Workgroup Secure Path v4.0C for Windows Workgroup Edition 5 licenses<br />
Edition Edition (including<br />
Secure Path v4.0C for Windows Workgroup Edition 10 licenses<br />
Windows Server 2003/32bit<br />
and 64-bit)<br />
Secure Path v4.0C for Windows Workgroup Edition 25 licenses<br />
231316-B26<br />
231317-B26<br />
231318-B26<br />
Active/passive controller Secure Path v4.0C for Windows Workgroup Edition 50 licenses 231319-B26<br />
configurations only Secure Path v4.0C for Windows Workgroup Edition Upgrade License 261715-B24<br />
Secure Secure Path Path Path v3.0C v3.0C for<br />
for<br />
Linux Linux Linux Workgroup Workgroup Edition Edition<br />
Edition<br />
Active/passive controller<br />
configurations only<br />
<strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> Secure Secure<br />
Secure<br />
Path Path v3.0C v3.0C for for NetWare NetWare<br />
NetWare<br />
Workgroup Workgroup Edition<br />
Edition<br />
Secure Path v4.0C for Windows Workgroup Edition for ProLiant BL line 8 licenses 325634-B23<br />
NOTE: NOTE: At present 64-bit Windows with Secure Path can operate in a homogenous<br />
configuration of multiple (up to 5) 2-node clusters.<br />
NOTE: NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path<br />
parameters for Windows.<br />
Secure Path v3.0C for Linux Workgroup Edition 1 license T3581A<br />
Secure Path v3.0C for Linux Workgroup Edition 5 licenses T3582A<br />
Secure Path v3.0C for Linux Workgroup Edition 10 licenses T3584A<br />
Secure Path v3.0C for Linux Workgroup Edition 25 licenses T3585A<br />
Secure Path v3.0C for Linux Workgroup Edition 50 licenses T3586A<br />
Secure Path v3.0C for Linux Workgroup Edition for ProLiant BL line 8 licenses T3583A<br />
NOTE: NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path<br />
parameters for Linux<br />
Secure Path v3.0C for NetWare Workgroup Edition 222411-B22<br />
Secure Path v3.0C for NetWare Workgroup Edition 5 licenses 231324-B22<br />
Secure Path v3.0C for NetWare Workgroup Edition 10 licenses 231325-B22<br />
Secure Path v3.0C for NetWare Workgroup Edition 25 licenses 231326-B22<br />
Secure Path v3.0C for NetWare Workgroup Edition 50 licenses 231327-B22<br />
QLogic QLogic QLogic Failover Failover Failover Driver Driver Driver or or<br />
or Provides a no cost multi-path solution for Linux when using specific QLogic or Emulex Host Bus<br />
Emulex Emulex MultiPulse MultiPulse<br />
MultiPulse Adapters. Active/passive or active /active controller configurations.<br />
for for Linux<br />
Linux<br />
For more information visit http://h18006.www1.hp.com/products/sanworks/multipathoptions/index.html<br />
Windows Windows MPIO MPIO Failover<br />
Failover<br />
Driver<br />
Driver<br />
Provides a no cost multi-path solution for Windows. Active/passive or active /active controller<br />
configurations.<br />
Microsoft Windows 2000 and Windows Server 2003 (32bit and 64bit) operating systems<br />
DSM driver is required from <strong>HP</strong> for operation and configuration:<br />
For more information visit http://h18006.www1.hp.com/products/sanworks/multipathoptions/index.html<br />
or http://www.microsoft.com<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 27
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Technical Specifications<br />
<strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong><br />
<strong>Smart</strong><br />
<strong>Array</strong><br />
<strong>Array</strong><br />
LED LED Indicators Indicators on on on Front<br />
Front<br />
(4)<br />
LED LED Indicators Indicators on on on Rear<br />
Rear<br />
Panel Panel (7)<br />
System heartbeat<br />
System UID<br />
Power On/Standby<br />
Fault detected in enclosure<br />
System UID<br />
SCSI Module Power indicator (1 per SCSI I/O module)<br />
SCSI Activity (1 per SCSI I/O module)<br />
Fibre Channel I/O card status (1 per Fibre I/O module)<br />
Fibre channel link status (2 per Fibre I/O module)<br />
Power supply status (1 per power supply)<br />
Fan Module status (1 per fan module)<br />
Interface Interface<br />
Ultra3 SCSI to Hard Drives<br />
Maximum Maximum Maximum Number Number of<br />
of<br />
Drives<br />
Drives<br />
2 Gb Fibre Channel to Hosts<br />
96 SATA hard drives in 8 MSA20 SATA enclosure or 56 SCSI hard drives in<br />
4 MSA30 enclosures<br />
Temperature Temperature Temperature Range Range Range Operating Operating<br />
50° to 95° F (10° to 35° C) up to 8000'<br />
Relative Relative Humidity Humidity Operating Operating<br />
10% to 90%<br />
Non-operating Non-operating<br />
Up to 95%<br />
-22° to 122° F (-30° to 50° C)<br />
Input Input Power Power Requirements Requirements Rated Rated Rated Input Input Voltage Voltage 100 to 240 VAC<br />
MSA<strong>1500</strong> MSA<strong>1500</strong> Controller<br />
Controller<br />
Shelf<br />
Shelf<br />
SCSI SCSI I/O I/O Module<br />
Module<br />
(Positioned in shelf)<br />
Fibre Fibre Channel Channel I/O<br />
I/O<br />
Module<br />
Module<br />
(Positioned in shelf)<br />
Rated Rated Input Input Frequency Frequency 47 to 63 Hz<br />
Rated Rated Rated Input Input Current Current 6.4A Max, 1A typical<br />
Input Input Power Power (max) 400W Max, 95W typical<br />
The supply will handle 90Vrms - 254 Vrms (100 - 240 V, +6%, -10%)<br />
Frequency is 47 - 63 Hz<br />
NOTE: NOTE: NOTE: Input Power and Heat Dissipation specifications are maximum values<br />
and apply to worst-case conditions at full rated power supply load. The<br />
power/heat dissipation for your installation will vary depending on the<br />
equipment configuration.<br />
2U 2U Rack Rack Form Form Form Factor Factor Dimensions Dimensions (H x W x D) 3.46 x 19.06 x<br />
24.32<br />
Weight Weight<br />
55 lbs<br />
Shipping Shipping Packaging Packaging Dimensions Dimensions (L x W x D) 32.50 x 11.25 x<br />
34.06<br />
Weight Weight (Gross) 68 lbs<br />
Dimensions Dimensions Dimensions (H x W x D) 3.2 x.92 x 14.62<br />
Weight Weight<br />
1.01 lbs<br />
Shipping Shipping Packaging Packaging Dimensions Dimensions (H x W x D) 19.88 x 9.06 x 2.76<br />
Weight Weight (Gross) 1.93 lbs<br />
Dimensions Dimensions (H x W x D) 3.2 x .92 x 14.62<br />
Weight Weight<br />
.96lbs<br />
Shipping Shipping Packaging Packaging Dimensions Dimensions (H x W x D) 19.88 x 9.0 6 x 2.76<br />
Weight Weight (Gross) 1.87lbs<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 28
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Technical Specifications<br />
User User Interface Interface<br />
Controller display with Status Indicators (2) and push buttons (4) on front of<br />
controller<br />
Electrical Electrical Interface Interface LVD (Low Voltage Differential)<br />
Protocol Protocol Support Support Wide Ultra3 SCSI<br />
SCSI SCSI Ports Ports<br />
2-ports per SCSI I/O card, up to 4 cards total<br />
Maximum Maximum Capacity Capacity 64 TB with SATA HDD, or 16.8 TB with SCSI HDD<br />
Logical Logical Drives Drives (LUN) Up to 32 Logical Drives<br />
Maximum Maximum Logical Logical Drive<br />
Drive<br />
size<br />
size<br />
2.0 TB<br />
<strong>Modular</strong> <strong>Modular</strong> SAN SAN <strong>Array</strong> <strong>Array</strong> 1000<br />
1000 User User Interface Interface<br />
Controller Display with Status Indicators (2) and Push Buttons (4)<br />
Controller<br />
Controller<br />
Status Indicators on front of Controller (16)<br />
<strong>Modular</strong> <strong>Modular</strong> SAN SAN <strong>Array</strong> <strong>Array</strong> Fibre<br />
Fibre<br />
Channel Channel I/O I/O Module<br />
Module<br />
Electrical Electrical Interface Interface Interface LVD (Low Voltage Differential)<br />
Protocol Protocol Support Support Wide Ultra3 SCSI (160 MB/s per channel)<br />
RAID RAID Support Support<br />
RAID 6 with <strong>HP</strong>'s Advanced Data Guarding technology (RAID ADG)<br />
RAID 5 (Distributed Data Guarding)<br />
RAID 1 + 0 (Mirroring + Stripping)<br />
RAID 0 (Stripping)<br />
Cache Cache Memory Memory Memory Up to 512 MB Read/Write (256 MB modules). If redundant controllers are<br />
used they must have equally configured cache<br />
ECC protection, battery-backed, and removable<br />
Standard as of November 19, 2002: 256 MB cache memory (single<br />
module)<br />
Cache Cache Batteries Batteries Transportable (battery-backed) and removable for easy replacement<br />
Upgradeable Upgradeable Firmware Firmware 2 MB flashable ROM<br />
Disk Disk Drive Drive and and Enclosure<br />
Enclosure<br />
Protocol Protocol Support<br />
Support<br />
<strong>HP</strong> Ultra 320, Ultra3, and Ultra2 SCSI 1-inch Universal drives<br />
Packaging Packaging<br />
Dimensions Dimensions (L x W x D) 15.5 x 12.0 x 3.25<br />
Connector Connector Type Type Type LC<br />
Number Number of of Fibre Fibre Channel<br />
Channel<br />
Ports<br />
Ports<br />
Bandwidth Bandwidth Bandwidth<br />
200 MB/s<br />
Weight Weight Weight (Gross) 2.5 lb<br />
One 2 Gb Fibre Channel Port using removable Small-Form-Factor-<br />
Pluggable Transceiver (SFP)<br />
Operation Operation Modes Modes Modes Fibre Channel Class 2 and 3 connectionless service<br />
Protocols Protocols Supported Supported Fibre Channel<br />
Packaging Packaging<br />
Dimensions Dimensions (L x W x D) 19.88 x 9.06 x 2.76<br />
Weight Weight Weight (Gross) 1.87 lbs<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 29
QuickSpe<strong>cs</strong> <strong>HP</strong> <strong>HP</strong> <strong>StorageWorks</strong> <strong>StorageWorks</strong> <strong>1500</strong> <strong>1500</strong> <strong>1500</strong> <strong>cs</strong> <strong>cs</strong> <strong>Modular</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Smart</strong> <strong>Array</strong><br />
<strong>Array</strong><br />
Technical Specifications<br />
Multi-Mode Multi-Mode Fibre<br />
Fibre<br />
Channel Channel Cables Cables Kits<br />
Kits<br />
(218960-B21)<br />
Cable Cable Type Type<br />
LC-LC (2 Gb to 2 Gb connections) and LC-SC (2 Gb to 1 Gb connections)<br />
50 Micron multi-mode Fiber<br />
Available Available Cable Cable Lengths Lengths Lengths 6.5 ft, 16.4 ft, and 49.2 ft (2 m, 5 m, and 15 m)<br />
Packaging Packaging<br />
Dimensions Dimensions (L x W x D) 11.5 x 9 x 1.5 in (29.2 x 22.8 x 3.8 cm)<br />
© Copyright 2007 Hewlett-Packard Development Company, L.P.<br />
The information contained herein is subject to change without notice.<br />
Weight Weight Weight (Gross) 0.75 to 1 lb (0.34 to 0.45 kg)<br />
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel<br />
Corporation. Unix is a registered trademark of The Open Group.<br />
The only warranties for <strong>HP</strong> products and services are set forth in the express warranty statements accompanying such products and<br />
services. Nothing herein should be construed as constituting an additional warranty. <strong>HP</strong> shall not be liable for technical or editorial<br />
errors or omissions contained herein.<br />
For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.<br />
DA - 11945 Canada — Version 19 — January 7, 2008 Page 30