SlideShare a Scribd company logo
1 of 89
Download to read offline
Operating Instructions
The New Elcometer 456
Coating Thickness Gauge
DFTTECH.COM
Gauge Dimensions: 141 x 73 x 37mm (5.55 x 2.87 x 1.46").
Gauge Weight: Integral: 156g (5.5oz) including batteries;
Separate: 161g (5.68oz) including batteries.
Applicable patents: US6243 661; US5886522; US6762603; US7606671;
GB2306009; GB2367135; GB2342450, DE10131827
© Elcometer Limited 2012 - 2015.All rights reserved. No part of this document may be reproduced, transmitted,
transcribed, stored (in a retrieval system or otherwise) or translated into any language, in any form or by any
means (electronic, mechanical, magnetic, optical, manual or otherwise) without the prior written permission of
Elcometer Limited.
www.elcometer.comTMA-0489 Issue 10
R
en
Pb Hg
DFTTECH.COM
Section Page
1 GAUGE OVERVIEW AND BOX CONTENTS........................................................... 4
2 GETTING STARTED................................................................................................. 5
3 TAKING A READING................................................................................................. 7
4 CALIBRATING THE GAUGE.................................................................................... 8
5 THE DISPLAY........................................................................................................... 9
6 THE GAUGE FEATURES......................................................................................... 12
7 MEASUREMENT MODES (ST)................................................................................ 25
8 BATCHING (ST)........................................................................................................ 26
9 DOWNLOADING DATA USING ELCOMASTER (BST)............................................ 35
10 ELCOMASTER MOBILE APPS (ST)........................................................................ 55
11 CLOUD COMPUTING USING ELCOMASTER (ST)................................................ 56
12 GETTING THE MOST OUT OF ELCOMASTER...................................................... 58
13 CALIBRATING THE ELCOMETER 456 (EBST)....................................................... 60
14 CHANGING THE WELCOME SCREEN (BST)......................................................... 64
15 GAUGE FIRMWARE UPDATES (BST).................................................................... 65
16 GAUGE ICONS & ERROR CODES (EBST)............................................................. 66
17 GAUGE MENU STRUCTURES (EBST)................................................................... 70
18 ABOUT IMO PSPC (ST)........................................................................................... 74
19 GAUGE TECHNICAL SPECIFICATIONS (EBST).................................................... 75
20 PROBE TECHNICAL SPECIFICATIONS (EBST)..................................................... 76
21 GAUGE & PROBE ACCESSORIES (EBST)............................................................ 80
22 ADDITIONAL REFERENCE INFORMATION........................................................... 82
23 LEGAL NOTICES & REGULATORY INFORMATION.............................................. 83
24 INDEX....................................................................................................................... 85
www.elcometer.com
R
en
CONTENTS
DFTTECH.COM
R
en
www.elcometer.com
WELCOME
Thank you for your purchase of this Elcometer 456 Coating
Thickness Gauge. Welcome to Elcometer.
Elcometer are world leaders in the design, manufacture and supply of
coatings inspection equipment. Our products cover all aspects of
coating inspection, from development through application to post
application inspection.
The Elcometer 456 Coating Thickness Gauge is a world beating
product. With the purchase of this gauge you now have access to the
worldwide service and support network of Elcometer.
For more information visit www.elcometer.com
ABOUTYOUR GAUGE
The Elcometer 456 Coating Thickness Gauge is a handheld gauge for
fast and accurate measurement of the thickness of coatings on metal
substrates.
The gauge is available in four models; Model E, B, S andT.
This manual describes the operation of all the Elcometer 456 models
and indicates, where necessary, which specific model(s) the feature is
available on in brackets after the feature.
All versions of the gauge feature an easy-to-use menu driven
graphical interface which guides the user through tasks such as
gauge configuration and calibration adjustment.
The gauge is available either with a built-in integral probe or as a
separate probe version. A wide range of probes is available to suit
requirements.
CONVENTIONS IN THESE INSTRUCTIONS
The Elcometer 456 is operated using a simple menu structure which
helps you get the most from your gauge.
As an example, the Languages option is located within Setup which is
under the Menu softkey and is shown in these instructions as:
Menu/Setup/Language
3
DFTTECH.COM
Packaging
The gauge is packed in cardboard packaging. Please ensure that this
packaging is disposed of in an environmentally sensitive manner.
Please Consult your Local Environmental Authority for further
guidance.
1 GAUGE OVERVIEWAND BOX CONTENTS
www.elcometer.com 4
R
en
Gauge Overview
1 LED Indicators - Red (left), Green (right)
2 Colour Screen
3 Multifunction Softkeys
4 On/Off Key
5 Internal Probe / Separate Probe Connection
6 USB Data Output Socket (below cover)
7 Battery Compartment (¼ turn open/close)
8 Wrist Strap Connection
Box Contents
§ Elcometer 456 CoatingThickness Gauge
§ Calibration Foils (Integral gauges)
§ Test Certificate
§ Wrist Harness
§ Protective Case (B, S &Tmodels)
§ Transit Case (Tmodel)
§ 1 x Screen Protector (S &Tmodels)
§ 2 xAABatteries
§ USB Cable & ElcoMaster™ Software
(S & T models)
§ User Guide
1
2
3
4
5
6
8
7
DFTTECH.COM
en
R
www.elcometer.com5
2 GETTING STARTED
Fitting the batteries
Your gauge is supplied with batteries ready to fit. To insert or
replace the batteries:
1. Lift the latch at the back of the gauge and +
rotate anticlockwise.
2. Remove the battery compartment cover.
3. Insert 2 batteries (type LR6/AA) taking care to
ensure correct battery polarity.
4. Replace battery compartment cover and rotate
the latch clockwise to close.
The battery condition is indicated by a symbol in the top right of the
display:
• Full symbol (orange) = batteries at full capacity
• Empty symbol (red, flashing) = batteries at lowest sustainable
level
To maximise battery life, ensure that Auto Screen Brightness is
selected, or the screen brightness is low via Menu/Setup/Screen
Settings/Screen Brightness and the Bluetooth is disabled (if you
are not using it) via Menu/Bluetooth and uncheck the Enable
Bluetooth radio button.
Connecting the probe (separate gauges only)
1. Rotate the probe plug to align the pins
2. Screw in the collar - clockwise
1
21
2
+
+
DFTTECH.COM
www.elcometer.com 6
R
en
Fitting the wrist harness
Awrist harness is supplied with each gauge. This can be fitted into the
right hand side of the gauge using the wrist strap connection. To fit the
harness, pass the harness loop through the wrist strap connection,
pass the main wrist harness through the loop and pull.
Switching the gauge on/off
Ÿ To switch on, press on/off key for more than 0.5 seconds.
Ÿ To switch off, press and hold on/off key until the screen blanks.
The gauge will switch off automatically after 5 minutes of inactivity.
To switch off this feature, press Menu/Setup and uncheck the Gauge
Auto Off radio button.
Selecting a language
When the gauge is switched on for the first time after dispatch from the
Elcometer factory the display will show the language selection screen:
1. Select your language using the éê softkeys
2. Follow the on screen menus
To access the language menu when in a foreign language:
1. Switch the gauge OFF
2. Press and hold the left softkey and switch the gauge ON
é3. Select your language using the softkeysê
The language can also be changed via Menu/Setup/Language
Selecting units
The Elcometer 456 can display readings in both metric and imperial
measurement units (microns, millimetres, mils or inches).
The appropriate measurement unit can be changed via
Menu/Setup/Units
Adjusting the beep volume
Each time a measurement is taken, the gauge will beep. The beep
volume can be adjusted and can even be switched off via
Menu/Setup/Beep Volume
DFTTECH.COM
www.elcometer.com7
en
R
3 TAKING A READING
1. Hold the gauge (integral) or the probe by its sleeve (separate gauge)
2. To take a reading, bring the probe down onto the surface whilst
holding it perpendicular
3. For subsequent readings, lift the probe off and then replace it onto
the coated surface
ü DO
• Hold the probe by the probe sleeve
• Gently place the probe onto the surface
• Allow the sleeve to make contact with the
surface - to improve accuracy
û DO NOT
• Drag the probe over the coated surface
• Bang the probe down hard onto the surface
• Allow the probe to hover over the surface as
this could result in a false reading
DFTTECH.COM
www.elcometer.com 8
R
en
90°
4 CALIBRATING THE GAUGE
Calibration adjustment is the process of setting the gauge to known values
of thickness to ensure accuracy on different substrate types, shapes and
surface finishes.
The calibration of the gauge can be adjusted using several different
methods for use in accordance with National and International Standards
and the calibration adjustment method chosen depends on the condition
of the substrate to be measured.
1. Press the Cal softkey
2. For alternative calibration methods,
select Cal/Cal Method
3. Select Calibrate and follow the on-screen
instructions
4. When prompted place the probe on the
centre of the foil(s) or on the uncoated
metal substrate
Foils can also be stacked to increase the thickness value.
The calibration method is indicated on the screen by a symbol - see
Multiple Calibration Methods on page 18.
Not all calibration methods are available for all gauge types. For a
comprehensive guide to each calibration method and the calibration
adjustment process see Multiple Calibration Methods on page 18.
When using an FNF probe it must be calibrated in both the ferrous mode
and in the non-ferrous mode to ensure accuracy of reading.
When using an Ultra/Scan probe in Scan Mode or Auto Repeat Mode
(see Measurement Modes on page 25), it must be calibrated using either
the Smooth or Rough/2 Point calibration method - see Multiple
Calibration Methods on page 18.
For more information on calibrating the Elcometer 456, see page 60.
DFTTECH.COM
5 THE DISPLAY
The Elcometer 456 gauge has a colour display:
• White characters: All measurement and statistical values.
• Orange characters: All menu items, statistical parameters and
symbols.
• Red: A measurement value which is outside set limits; a limit symbol
when the limit value has been exceeded (Model S & T).
• - - - indicates reading outside range of probe.
If you see the Cal softkey flashing, the gauge should be calibrated.
www.elcometer.com9
en
R
j
b
a
c
f
m
l
n
o
p
q
I
h
k
s
u
r
t
w
v
d
e
g
DFTTECH.COM
Model
a Green LED EBST
b Battery Life Indicator EBST
c Bluetooth On ST
d Substrate Type - F, N, FNF EBST
e Calibration Method BST
f Reading Outside Calibration Warning On T
g Upper Limit On ST
h Units of Measurement - µm, mils, mm, inch EBST
i Batch Type - normal, counted average, IMO ST
j Menu Softkey EBST
k Display Softkey BST
l Red LED - Reading outside limit/ IMO Fail ST
m Batch Name (when in batching) T
Date & Time (when not in batching) ST
n User Selectable Statistics - 4 rows BST
o Reading Value EBST
p Calibration Softkey EBST
q Batch / Data Softkey BST
r Bar Graph - highest, lowest & average reading BST
s Lower Limit On ST
t Measurement Mode - Standard, Auto Repeat, Scan T
u Softkeys EBST
v Run Chart - last 20 readings ST
w Upper & Lower Limits On ST
For a complete list of icons, see “Gauge Icons” on page 66 - 68
www.elcometer.com 10
R
en
DFTTECH.COM
Reading display size (BST)
The character size of the measurement value on
the display increases or decreases depending on
the number of statistics that are displayed; or if a
graph is displayed on the measurement screen .
To maximise the reading size, either:
Ÿ reduce the number of statistical values that
are displayed via Display/Statistics/Select
Statistics, or
Ÿ display the reading only by checking the
Display/Readings Only radio button.
www.elcometer.com11
en
R
DFTTECH.COM
6 THE GAUGE FEATURES
The Elcometer 456 coating thickness gauge has a number of easy to use
features and functions to help the user be more efficient.These include:
Fast reading rate (EBST)
The Elcometer 456 is capable of taking greater than 70 accurate,
repeatable and reproducible measurements every minute.
Easy to use menu structure in more than 30 languages (EBST)
Designed to be intuitive, the Elcometer 456 menus and calibration
instructions are available in multiple languages via
Menu/Setup/Language.
Bright colour screen (EBST)
Each gauge is supplied with a scratch and solvent resistant 2.4"
(60mm) TFT colour screen which clearly displays the reading. The
screen brightness can be adjusted manually (EBST) - via
Menu/Setup/Screen Settings/Screen Brightness/Manual or
automatically (BST) using the gauge’s ambient light sensor which can
be switched on via Menu/Setup/Screen Settings/Screen
Brightness/Auto.
Battery or USB Powered (EBST)
Each gauge can be powered either using 2 x AA lithium, alkaline or
rechargeable batteries or by connecting the Elcometer 456 to your PC
via a USB cable.
Two year gauge warranty (EBST)
The Elcometer 456 gauge is supplied with a 1 year warranty against
manufacturing defects. To extend this warranty to 2 years, simply
register your gauge via the elcometer.com website.
Emergency light mode (BST)
If all the lighting fails during an inspection in dark environments, the gauge
is fitted with an emergency light feature - once selected
(Menu/EmergencyLight),thedisplayturnsbrightwhite.Toswitchoffthis
functioneitherpressandholdtheEscsoftkeyorpoweroffthegauge.
R
en
www.elcometer.com 12
DFTTECH.COM
Automatic rotating display (BST)
Using the internal accelerometer, the gauge
will automatically rotate the display to allow
you to easily read the thickness value in any
orientation - 0°, 90°, 180° & 270°.
This function can be switched off by un-checking
Menu/Setup/Screen Settings/Auto Display
Rotation
Gauge firmware updates (BST)
Using Elcometer’s free data management software, ElcoMaster™,
users can receive prompts when there is a gauge firmware update
available for their model version.
When the Elcometer 456 is connected (via USB), to any computer
with an internet connection and with ElcoMaster™ installed,
ElcoMaster™ highlights the availability of a firmware update,
identifies to the user the new features and guides the user through the
gauge firmware update process.
Caution, before upgrading your gauge firmware, ensure that you have
downloaded all inspection readings from the gauge. For more
information regarding ElcoMaster™ see page 35 Downloading Data.
Bluetooth™ (ST) and USB Data output (BST)
Elcometer 456 gauges have the ability to transfer data via USB (BST)
to a computer or wirelessly via Bluetooth™ (ST) technology to PC’s,
PDA’s or mobile phones which are Bluetooth™ enabled using
ElcoMaster™ or ElcoMaster™ MobileApps respectively.
B l u e t o o t h ™ d a t a o u t p u t c a n b e s w i t c h e d o n v i a
Menu/Bluetooth/Enable Bluetooth. For more information
regarding ElcoMaster™ see page 35 Downloading Data.
ElcoMaster™ Data output (BST)
Users can download data from any Elcometer gauge directly into
ElcoMaster™ by connecting the gauge to the PC and following the on
screen prompts.
www.elcometer.com13
en
R
DFTTECH.COM
Symbol / icon Model Description
η BST The number of readings taken
x BST Mean (average)
σ BST Standard deviation
Hi BST Highest reading taken
Lo BST Lowest reading taken
cv% BST Coefficient of variation; The COV is defined as the ratio of
the standard deviation to the mean and is a normalised
measure of dispersion - when comparing batches with
widely different means, one should use the coefficient of
variationforcomparisoninsteadofstandarddeviation(σ).
Once the data has been transferred to the computer, the user can
produce professional reports in seconds. Data can also be transferred
®
into programs, such as Excel , in a similar manner.
For more information regarding ElcoMaster™ see page 35
Downloading Data.
Counted Average (BST)
Users can define the number of individual gauge readings to be taken
within a spot or measurement area using the Counted Average
function. The gauge stores the average of the individual readings into
memory. The individual readings within the counted average are not
saved. Select Display/Statistics/CountedAverage.
Counted Average is also available when in Batching (ST) - see
BatchTypes on page 32.
On Screen Statistics (BST)
User selectable statistical and general measurement information can
be displayed on the gauge. The information to be displayed can be
selected and managed by selecting the Display softkey.
Ÿ Up to 8 statistics can be selected to be displayed on the reading
screen via Display/Statistics/Select Statistics
Ÿ Ensure that Display/Readings & Selected Stats is also checked.
Ÿ To view all statistics select Display/Statistics/ViewAll
The following statistical and general information can be displayed on
your gauge:
R
en
www.elcometer.com 14
DFTTECH.COM
Symbol / icon Model Description
EIV BST Elcometer index value; Used to assess a coating’s
overall quality. Ideal for use in the automotive refinishing
industry.USApatentnumberUS7606671.
NDFT ST Nominal dry film thickness; The target or specified dry
film coating thickness value.
IMO PSPC ST International Maritime Organisation’s Performance
Standard for Protective Coatings clearly defines the
acceptance criteria for a coating. The Elcometer 456
can be quickly set up to display these parameters:
% > N ST The percentage of readings greater than or equal to the
Nominal Dry FilmThickness Value.
90
% 100 ST The percentage of readings between 0.9 x NDFT and
the NDFT.
90:10 ST Displays either pass (ü) or fail (X)
To pass the IMO PSPC 90/10 rule:
Ÿ At least 90% of all dry film thickness readings shall
be greater than or equal to the NDFTvalue, and
Ÿ none of the remaining measurements shall be below
0.9 x NDFT
X! ST If all the measurements taken at any point are greater
than 0.9 x NDFT, but less than 90% of the readings are
greater than or equal to the NDFT, were the inspection
to stop, then the IMO PSPC condition would be a fail.
Statistically, however, were more measurements to be
taken which were all greater than or equal to the NDFT,
then there would come a time when the IMO PSPC
condition returns to a pass. This is depicted by the
“failing” icon - X!. For more information on the IMO
PSPC seeAbout IMO PSPC on page 74.
ST Low Limit
ST High Limit
ST Number of readings below the low limit
ST Number of readings above the high limit
User definable warning limits can be set. Once the
reading exceeds the limit the gauge notifies the user by
turning the reading and relevant limit icon red, flashing
the red LED, and sounding the alarm beep. For more
information see Limits on page 23.
www.elcometer.com15
en
R
n
n
DFTTECH.COM
Analogue Bar Graph (BST)
ByselectingDisplay/Readings&BarGraph
theusercanviewananaloguerepresentation
of the current thickness value together with
the highest (Hi), lowest (Lo) and average (x)
reading. The graph is updated automatically
wheneachreadingistaken.
The values on the top left and right of the bar
signify the measurement range using the
thin calibration foil value less 10% and the
thick calibration foil value plus 10%. If
calibrated using the factory calibration, the
probe scale range ±10% is used. If limits are
set, the limit values ±10% are used and the
relevant limit icon is displayed above the bar
intheappropriateposition.
With Limits: The current measurement is
displayed as a white or red bar; white if
within set limits, and red if outside set limits.
If below the lower limit, the left arrow head
is also filled red and if above the upper limit,
the right arrow head is filled red.
If the next measurement taken is within set limits, the left or right arrow
outline will remain red to signify that the previous reading was outside
set limits.
WithoutLimits:Thecurrentmeasurementisdisplayedasawhitebar.
If outside the measurement range, the left or white arrow head is also
filled white.
If the next measurement taken is within range, the left or right arrow
outline will remain white to signify that the previous reading was
outside range.
4 Users can choose to show Readings & Selected Stats (ST) - see On Screen
Statistics on page 14, Readings & Run Chart (ST) - see Run Chart on page 17,
Readings & Bar Graph (BST) or Readings Only (BST). Readings & Run Chart is
only available when in Batching, it is not available in Standard (Immediate) Mode.
R
en
www.elcometer.com 16
DFTTECH.COM
Run Chart (ST)
By selecting Display/Readings & Run Chart the user can view a line
trend graph of the last 20 measurements. The graph is updated
automatically when each reading is taken.
Up to five horizontal axes are displayed representing different values /
statistics as follows:
Ÿ Highest reading in the batch “ ”
Ÿ Lowest reading in the batch “ ”
(for batches of more than one reading)
Ÿ Mean of readings in the batch “ ”
(for batches of more than one reading)
Ÿ High limit for the batch “ ” (when enabled)
Ÿ Low limit for the batch “ ” (when enabled)
The readings are displayed as white or red points; white if a reading is
within limits (or no limits have been set), and red if outside set limits.
When in Scan Mode (T) - see Measurement Modes on page 25, the
Analogue Bar Graph is displayed on screen whilst scanning. This is
replaced by the Run Chart when the scan is completed.
The highest and lowest reading for each
scan is displayed on the run chart above and
below the average value together with either
a white or red vertical line; white if within set
limits, and red if outside set limits.
The highest, average and lowest reading
values for the last scan are also displayed
under the run chart.
4 Users can choose to show Readings & Selected Stats (ST) - see On Screen
Statistics on page 14, Readings & Run Chart (ST), Readings & Bar Graph (BST) -
see Analogue Bar Graph on page 16 or Readings Only (BST). Readings & Run
Chart is only available when in Batching, it is not available in Standard (Immediate)
Mode.
Time and date (ST)
Oncetheappropriatetimeanddatehasbeenset(Menu/Setup/Timeand
Date), the user can display the time and date at the top of the Elcometer
456displayviaMenu/Setup/TimeandDate/DisplayTimeandDate.
www.elcometer.com17
en
R
DFTTECH.COM
Ÿ The time format can be set to either the 12 hour or 24 hour clock via
Menu/Setup/Time and Date/Set Format/Set Time Format
Ÿ The date format can be set to either dd/mm/yyyy, mm/dd/yyyy or
yyyy/mm/dd via Menu/Setup/Time and Date/Set Format/Set
Date Format
Please note that the time and date is replaced by the batch name
when the gauge is in Batch mode.
When a batch is created, re-opened (or when the gauge is switched
on whilst in batch mode) and when each reading is taken, the time and
date details are stored within the batch - allowing the user to have an
accurate record of when the measurements were taken. The time and
date stamp for each reading is displayed on ElcoMaster™.
Multiple calibration methods (EBST)
Calibration adjustment is the process of setting the gauge to known
values of thickness to ensure accuracy on different substrate types,
shapes and surface finishes and is often referred to as simply the
“calibration”.
The calibration of the gauge can be adjusted using several different
methods for use in accordance with National and International
Standards and the calibration adjustment method chosen depends on
the condition of the substrate to be measured.
The calibration method is indicated on the screen by a symbol.
When using an FNF probe it must be calibrated in both the ferrous
mode and in the non-ferrous mode to ensure accuracy of reading.
When using an Ultra/Scan probe in Scan Mode or Auto Repeat
Mode (see Measurement Modes on page 25), it must be calibrated
using either the Smooth or Rough/2 Point calibration method.
When switching between the Scale 1 and Scale 2 functions of the
scale 2 probes (Menu/Setup/Probe) the Elcometer 456 should be re-
calibrated to ensure accuracy across the appropriate measurement
range.
www.elcometer.com 18
R
en
DFTTECH.COM
Method Description Icon Model
Zero A simple method for calibrating on smooth
substrates. Simply place the probe on the
uncoated metal and the gauge will adjust the
calibration accordingly. Also known as the single
point calibration method.
BST
Smooth This is a more accurate method of calibrating the
gauge than the Zero method as it requires the
user to calibrate the gauge using a foil and the
un-coated substrate.
The gauge’s on-screen calibration instructions
will guide the user through the calibration routine.
When selecting the foil value, the user should
choose a thickness that is close to but greater
than the expected dry film thickness value.
BST
Rough /
2 Point
Ideal for calibrating the gauge on both profiled
metal substrates (when the uncoated surface is
accessable) and substrates where there are
significant differences in the magnetic (F) or
electrical (N) properties of the substrate. For
example cast iron, high carbon steel or some
non-magnetic stainless steel alloys.
The calibration requires 2 foil values - one above
the expected dry film thickness, and one below.
The gauge will guide the user through the
process with on screen instructions.
EBST
Zero Offset This is the ISO 19840 method for coatings on
steel surfaces roughened by blast cleaning or
when the substrate profile is unknown, or not
accessible. The calibration uses the smooth
surface technique, and a correction value (zero
offset) is applied to each reading to account for
the effect of the roughened surface; the value of
the offset depends on the initial surface profile
and is described in ISO 19840 as follows:
ST
Profile according to
ISO 8503-1
Correction Offset
*Value µm (mils )
Fine 10 (0.4)
Medium 25 (1.0)
Coarse 40 (1.6)
* mils values are calculated and for reference
as ISO 19840 indicates metric units only
www.elcometer.com19
en
R
DFTTECH.COM
Method Description Icon Model
Auto This is a calibration method unique to the
Elcometer 456 and has been designed to simplify
and speed up the calibration process for those
users who are calibrating their gauge using the
same foil values each time.
When the Auto calibration method is selected,
the user is asked to pre-program the high and low
foil values. The low foil value can be set to 0.0µm
(0.0mils) for un-coated substrates.
Once these foil values have been set up,
selecting the calibrate routine allows the user to
simply place the probe on the high foil three
times, followed by the low foil three times and the
gauge is automatically calibrated - returning the
user to the main reading screen - automatically.
ST
Factory By selecting this calibration method the
Elcometer 456 returns the calibration to the
gauge’s factory calibration settings.
The factory calibration method should only be
used if there is no other means of calibration (e.g.
lost foils, lack of access to substrate, etc.).
EBST
Pre-defined Calibration Methods (ST)
In addition to the standard calibration methods described on pages
16 - 18, the Elcometer 456 has a four pre-defined calibration methods
which follow relevant standards.
These pre-defined calibration methods not only define the calibration
routine to be used, but also set up the data collection method, as
defined by the appropriate standard.
For this reason, pre-defined calibration methods can only be selected
whilst the gauge is in batching mode. For more information on
batching or data collection methods, see Batching on page 26.
www.elcometer.com 20
R
en
DFTTECH.COM
Method Description Icon Model
ISO Sets the calibration method to Zero Offset and
sets the Counted Average to 5 - in accordance
with ISO19840.
ST
SSPC PA2 Sets the calibration method to Rough/2 Point and
sets the Counted Average to 3 - in accordance
with SSPC PA2.
ST
Swedish Sets the calibration method to Rough/2 Point and
sets the Counted Average to 5 - in accordance
with Swedish standards.
ST
Australian Sets the calibration method to Zero Offset, and
sets the Counted Average to 5 - in accordance
with AS standards.
ST
For more information on how to calibrate the gauge, see Calibrating the
Elcometer 456 on page 60.
User-programmable calibration memories (T)
The Elcometer 456 Model T allows users to store into memory up to
three calibrations. Once a calibration memory has been saved, the
user can select the calibration memory - without the need to
re-calibrate the gauge.
Calibration memories are ideal for users who are inspecting coatings
on various curvatures, blast profiles or coating thicknesses.
Using the gauge’s alpha-numeric function, users can re-name the
calibration memory to suit the calibration setting.
For example:
Ÿ A user who is inspecting coatings on two blast profiles - shot and
grit could store calibrations into Cal Memory 1 and Cal Memory 2
and re-name them ‘Shot’and ‘Grit’respectively
Ÿ A user measuring on flat and curved surfaces could store the
calibrations into ‘Flat cal’and ‘Curved cal’.
Ÿ Thick and thin coating thickness calibrations can also be saved
and renamed ‘320µm’and ‘120µm’
For more information on re-naming calibration memories, see Alpha-
numeric naming of batches and cal memories on page 27.
www.elcometer.com21
en
R
DFTTECH.COM
Outside calibration warning (T)
In order to achieve the most accurate reading the gauge should be
calibrated to the substrate type, shape and profile using the
appropriate calibration method together with foil values that are
slightly above the target dry film thickness.
When using the gauge’s calibration memories, or batching (see
Batching on page 26) different calibration foil values may be used in
each calibration.
value if using Rough/ 2 point) the gauge reading alarm sounds a triple
beep and the Calibration Check icon (located above the units symbol)
turns red. This feature does not amend or tag any reading, it is a real
time warning feature only.
Calibration lock (BST)
To avoid accidental amendments to the calibration settings switching
on the Cal/Calibration Lock feature’ locks’ the user from undertaking
any changes to the calibration without first un-checking the
Cal/Calibration Lock feature.
When the Calibration Lock is enabled, users can still test the
calibration via Cal/Test Calibration but will be unable to validate or
re-calibrate the gauge.
The calibration can also be locked using a PIN Code, see page 63 for
more information.
Once the Outside calibration warning
function Cal/Calibration Check has been
switched on, if a coating thickness reading
is taken which is more than 10% above the
foil value (and 10% below the lower foil
www.elcometer.com 22
R
en
DFTTECH.COM
Gauge Memory (BST)
The Elcometer 456 versions are supplied with a varying level of
memory:
Model E: No memory
Model B: The Model B gauge’s ‘rolling statistics’ provides
accurate statistical values for all measurements
taken since the statistics were last cleared
(Display/Clear Statistics). The last 5 readings,
however, can be displayed by pressing the Data
softkey.
Model S: 1,500readingscanbestoredintothegauge’smemory
Model T: A total of 150,000 readings can be stored into the
gauge’s memory either in a single batch or in up to
2,500 batches (see Batching on page 26). Each
batch can be individually named and can have its
own unique calibration.
Limits (ST)
During the inspection process coatings can often have specified
minimum and/or maximum thickness values.
For example, coatings that have been applied too thinly over a
surface profile can lead to rust spots appearing on the peaks of the
profile. Similarly too thick a coating can also lead to premature coating
failures.
Users can program upper and/or lower warning limits into the
Elcometer 456 gauge by selecting Menu/Set Limits/Set Upper or
Menu/Set Limits/Set Lower.
To switch the limits on, the user should ensure that the Enable Limits
radio button is checked.
Ÿ When an Upper Limit has been set up and enabled the “ ” icon is
displayed.
Ÿ When a Lower Limit has been set up and enabled the “ ” icon is
displayed.
Ÿ If both Upper and Lower limits have been set up and enabled then
the two icons are displayed together as “ ”.
www.elcometer.com23
en
R
DFTTECH.COM
When the Elcometer 456 gauge takes a
reading which is outside the set limits the
following occurs:
Ÿ The Red LED flashes
Ÿ The reading is displayed in red
Ÿ The alarm beeps 3 times
Ÿ The associated limit icon turns red
In addition, the number of readings above limit (or below limit as
applicable) statistic is incremented. In Batching, the reading is
tagged with either the high or low icon as appropriate. For more
information see Batching on page 26.
To switch off a particular limit go to Menu/Set Limits/Set Upper or
Menu/Set Limits/Set Lower and set the limit value to Off using the up
and down soft keys.
The programmed limit values can be displayed on the reading screen
via Display/Statsitics/Select Statistics and checking the appropriate
radio button. The maximum number of statistics that can be displayed
on the reading screen at the same time is 8.
If a low limit has been set up, the upper limit value cannot be lower
than the pre-set lower limit.
Individual limits can also be set up for each batch on Model T gauges.
For more information see Batching on page 26.
Gauge Welcome Screen (BST)
Users can adjust the start up screen on their Elcometer 456 gauges
via the ElcoMaster™ software - see page 64 for more information.
www.elcometer.com 24
R
en
DFTTECH.COM
7 MEASUREMENT MODES (ST)
7.1 The Elcometer 456 gauges have four measurement modes:
Standard (Immediate) Mode (ST): Where readings are taken, rolling
statistics calculated (and displayed), but individual values are not
stored in the memory.
Scan Mode (T): Specifically designed for use with Elcometer 456
Ultra/Scan Probes - see page 79, when Scan Mode is selected, the
user can slide the Ultra/Scan Probe over the entire surface area. As
the probe is lifted off the surface the average (x), lowest (Lo) and
highest (Hi) coating thickness values are displayed. When Batching,
each set of three readings can be shown on a Run Chart - see page 17
and stored into memory.
Scan Mode with Hold (T):As above but allows the probe to be lifted off
the surface for a maximum of 1.5 seconds and replaced without starting
a new set of readings - allowing the user to avoid holes, weld seams, etc.
inthesubstratewithoutaffectingthemeasurementresults.
Auto Repeat Mode (T): When the probe is placed onto the coated
substrate inAuto Repeat Mode, the gauge automatically takes readings
at a rate of 140 per minute until the probe is removed from the substrate.
WhenBatching,eachindividualreadingisstoredintothememory.
7.2 NAVSEA MODE (T): Displays the reading to the nearest 1mil (1µm)
above 10mils (254µm) and 0.1mil (0.1µm) below 10mils (254µm). To
select NAVSEA mode, press Menu/Setup/NAVSEA or Batch/New
Batch/NAVSEA.
4 Scan and Auto Repeat Modes are only available on Elcometer 456 Model T separate
gauges. The probe end cap must be fitted to the Ultra/Scan Probe when used in these
modes to avoid damage to the probe tip. Use in these modes without the cap will
invalidate the probe warranty.
Hi, x & Lo
www.elcometer.com25
en
R
1, 2, .......n
DFTTECH.COM
8 BATCHING (ST)
Readings can be stored into memory in batches. Batches allow the
user to collate readings for easier analysis of large structures or
complex assemblies. Elcometer 456 Model T gauges can store a total
of 150,000 readings in up to 2,500 batches, the Model S has one batch
of up to 1,500 readings.
The Elcometer 456 has the following batching functions:
Ÿ Create a new batch (ST); Batch/New Batch
Ÿ Open an existing batch (ST); Batch/Open Existing Batch
Ÿ Rename an existing batch (T); Batch/Edit Batch/Rename Batch
Ÿ Copy a batch - including all calibration and limit setups (T);
Batch/Copy Batch
Ÿ Clear all the readings within the batch - but leaving all calibration
and limit setups (ST); Batch/Edit Batch/Clear Batch
Ÿ Review the readings, statistics, calibration, batch information (ST)
and a graph of the readings (T); Batch/Review Batch
Ÿ Delete a Batch (ST), or all batches (T), entirely from the gauge;
Batch/Edit Batch/Delete Batch
Ÿ Delete the last reading entirely or delete the reading, but mark the
reading as deleted in the batch memory (ST) - Batch/Deleted
Reading/Delete With Tag and Batch/Deleted Reading/Delete
Without Tag respectively.
Creating a new batch (T)
When using batching for the first time, or when you wish to open a new
batch, press Batch/New Batch.The user can now:
Ÿ Openthebatchandtakereadings;Batch/NewBatch/OpenBatch1
Ÿ Rename the batch - before opening it via Batch/New
Batch/Rename Batch 1. (See Alpha numeric naming Batches &
Cal Memories on page 27)
www.elcometer.com 26
R
en
DFTTECH.COM
Ÿ Select the appropriate calibration method - Batch/New Batch/
Batch Calibration (see Multiple calibration methods on page 18)
Ÿ Choose the type of batch (normal, counted average or IMO PSPC)
before opening it via Batch/New Batch/Batch Type (see Batch
Types on page 32)
Ÿ Set up specific batch limits via Batch/New Batch/Batch Limits
(see Limits on page 23)
Ÿ Set up a fixed batch size via Batch/New Batch/Fixed Batch Size
(see Fixed Batch Size on page 33)
Once all the batch settings have been created, press Batch/New
Batch/Open Batch 1 - where ‘Batch 1' may now be a re-named as
required.
Alpha numeric naming batches & cal memories (T)
When in batching - or setting up a calibration memory (see Calibration
Memories on page 21) - the user can rename the batch or cal memory
to a more appropriate name.
When a new batch is created, the gauge automatically names it
‘Batch n’ - where ‘n’ is the next unused batch number; e.g. Batch 1,
Batch 2, Batch 3, etc.
To rename a batch either:
Ÿ when creating a new batch press Batch/New Batch/Rename
Batch 1; or
Ÿ press Batch/Edit Batch/Rename Batch and select the Batch to be
renamed from the list of existing batches
To rename a calibration memory:
Ÿ pressCal/CalMemory1; Cal/CalMemory2orCal/CalMemory3
Ÿ then select Rename Cal Memory n (where n=1, 2 or 3)
This then opens up the renaming procedure to enable the user to
rename the batch or cal memory.
www.elcometer.com27
R
en DFTTECH.COM
The current name of the batch (or
cal memory) is in white in the
middle of the display with a yellow
‘cursor’ icon to the right of the
name.
Using the left arrow, right arrow
and Select softkeys, the user can
rename the batch or cal memory
as required.
The yellow, raised character or
function is the item that will be
‘chosen’ by pressing the Select
soft key.
Pressing the Esc softkey at any time cancels the whole operation
without making any changes to the original name.
To store the re-named ‘name’ highlight OK and press the Select
softkey.
Character Action
OK
Stores the name and returns the user to the previous
screen
Deletes the last character of the name
A, B, C... Selects the character A, B or C, etc.
Inserts a space
123
Changes the selection characters to:
1 2 3 4 5 6 7 8 9 0
ABC
Changes the selection characters to:
A B C D E F G H J K L M N O P Q R S T U V W X Y Z
ÀÇü
Changes the selection characters to:
ÀÁÂÃÄÅÆÇÈÉÊËÌÍÎÏÐÑÒÓÔÕÖÙÚÛÜÝÞßµm
$%&
Changes the selection characters to:
! # ’ £ $ € % & * [ ] _ - + /  < > : @ ; ”
www.elcometer.com 28
en
R
DFTTECH.COM
Opening an existing batch (ST)
By selecting Batch/Open Existing Batch on the Model T, the user will
find a list of all the batches that have already been created, together
with the number of readings stored in each batch.
To open a particular batch use the up and down arrow soft keys and
select the appropriate batch.
The Elcometer 456 will return the gauge to the main reading screen
and the selected batch name will be shown at the top of the display
(together with a unique gauge batch id number - allowing no two
batches to have exactly the same name).
As the Model S only has one batch, the batch will open automatically.
Copying an existing batch (T)
By selecting Batch/Copy Batch the user will find a list of all the
batches that have already been created, together with the number of
readings stored in each batch.
To copy a particular batch use the up and down arrow soft keys and
select the appropriate batch.
The Elcometer 456 will then copy all the batch settings - calibration
and foil values, batch type, cal method, warning limits, and the batch
name - and then ask the user whether they wish to rename the batch.
Pressing the Yes softkey the user will then be asked to rename the
batch using the renaming procedure described on page 27.
Pressing the No softkey (or pressing the Esc softkey whilst in the
renaming procedure) will make the Elcometer 456 copy the existing
batch name to the new batch - thereby two batches will have the same
batch name.
Copying a batch does not copy the individual readings within that
batch.
Clearing an existing batch (ST)
By Selecting Batch/Edit Batch/Clear Batch on the Model T, the user
will find a list of all the batches that have already been created,
together with the number of readings stored in each batch.
To clear a particular batch’s individual readings only, use the up and
down arrow soft keys and select the appropriate batch.
www.elcometer.com29
en
R
DFTTECH.COM
As the Model S only has one batch, it is selected automatically.
After a request for confirmation, the gauge will clear the readings from
the selected batch and return the gauge to the list of batches (T) or the
Batch Menu (S).
To clear another batch (T), repeat the procedure. To return the gauge
back to the previous menu, press the Back softkey.
The user can clear all batches via Batch/Edit Batch/Clear Batch/All
Batches (T).
Reviewing an existing batch (ST)
By selecting Batch/Review Batch the user will find a list of all the
batches that have already been created, together with the number of
readings stored in each batch.
To review a particular batch use the up and down arrow soft keys and
select the appropriate batch. As the Model S only has one batch, it is
selected automatically.
The Elcometer 456 will then open up the Review Batch menu, allowing the
userto:
Ÿ Review the statistics of the batch
Ÿ Review the batch information, including:
Ÿ the date and time the batch was created
Ÿ the batch type - normal, counted average or IMO PSPC
Ÿ the probe type and serial number used to take the readings
Ÿ the calibration method - smooth, rough/2 point, etc.
Ÿ the batch limits (if set)
Ÿ Review the batch’s calibration information, including:
Ÿ the date and time the batch was last calibrated or verified
Ÿ the substrate type (or types if using an FNF probe)
Ÿ the probe type and serial number
Ÿ the calibration method - smooth, rough/2 point etc.
Ÿ the foil values used in the calibration
Ÿ Review the individual readings.The Elcometer 456 displays:
Ÿ the readings in numerical order, the first reading is at the top
Ÿ the substrate, time and date of measurement
Ÿ icons indicating a reading above “ ” or below “ ” the limit
Ÿ deleted readings icon “ ” is displayed if “Delete With Tag”
selected, (see page 26 for more information).
Ÿ Review a graph of the individual readings (T), see page 31.
www.elcometer.com 30
en
R
DFTTECH.COM
Batch Readings Graph (T)
By selecting Batch/Review Batch/Batch Graph the user can review
all readings in the selected batch as a graph.
Up to five horizontal axes can be displayed representing different
values / statistics as follows:
Ÿ Highest reading in the batch “ ”
Ÿ Lowest reading in the batch “ ”
(for batches of more than one reading)
Ÿ Mean of readings in the batch “ ”
(for batches of more than one reading)
Ÿ High limit for the batch “ ”(when enabled)
Ÿ Low limit for the batch “ ”(when enabled)
The readings are displayed as white or red
vertical bars; white if a reading is within limits
(or no limits have been set), and red if outside
set limits.
Iftherearemorereadingsinthebatchthancanbe
displayedonasinglescreen,multiplereadingswill
becombinedintoonebar.Shouldasinglereading
within the ‘combined bar’ be outside the enabled
limits,thewholebarwillbered.
Pressing the Zoom+ softkey, allows each
individual reading to be displayed, thereby
showing the individual readings outside the
limits.
When zoomed in, the graph will always display
the first 25 readings. Pressing the ç softkey
will display the last 25 readings taken.
Subsequent presses of the ç softkey will scroll
backwards, pressing the è softkey will scroll
forwards through the readings, 25 readings at
a time.
Pressing the Zoom- softkey returns to the original overview graph of
all readings in the batch.
ToreturnthegaugetotheBatchReviewmenu,presstheBacksoftkey.
www.elcometer.com31
en
R
DFTTECH.COM
Delete an existing batch (ST)
By Selecting Batch/Edit Batch/Delete Batch the user will find a list of
all the batches that have already been created (T) or a single batch (S),
together with the number of readings stored in each batch.
To delete a particular batch’s individual readings only use the up and
down arrow soft keys and select the appropriate batch.
After a request for confirmation, the gauge will delete the selected
batch and return the gauge to the list of batches.
To delete another batch, repeat the procedure, to return the gauge
back to the previous menu, press the Back softkey.
The user can delete all batches from the gauge by selecting
Batch/Edit Batch/Delete Batch/All Batches (T).
Exit Batching (ST)
To stop using the Batching Mode and return to the Immediate mode
select Batch/Exit Batching.
Batch Types (ST)
When saving readings into a batch you have a choice of how the
readings are managed within the gauge:
Normal: Each reading is saved into memory.
Press Batch/New Batch/Batch Type and then select Normal.
The batch type can only be changed when creating a new batch.
Counted Average: The average of a predefined number of
readings is saved into memory. For example a counted average of
3 means:
The average of [Reading 1 + Reading 2 + Reading 3] is stored
as the first measurement saved in the memory.
Likewise the average of readings 4 - 6 are stored as the second
measurement in the memory, etc.
The individual readings within the counted average (1.2.3,
4.5.6, etc.) are not saved.
Press Batch/New Batch/Batch Type and then select Counted
Average.
The batch type can only be changed when creating a new batch.
www.elcometer.com 32
en
R
DFTTECH.COM
The Elcometer 456 then asks the user to set the counted average
value. Using the up and down arrow softkeys, set the counted
average from 2 - 99 and press the Ok softkey.
This returns the user to the previous screen. Press the Back
softkey to continue setting up the new batch as required before
opening the new batch.
If Statistics are displayed whilst measuring using the counted
average function (CAF) when taking the readings used to calculate
the CAF measurement, the gauge will display the rolling statistical
calculations of the individual readings until all the readings that go
into calculating the CAF measurement are taken. At this point the
statistics then display the values of the stored CAF measurements.
IMO PSPC: If you are inspecting coating thickness according to the
International Maritime Organisations Performance Standard for
Protective Coating, selecting the IMO PSPC batch type and then
subsequently opening the batch, the gauge automatically:
• Asks the user to confirm the NDFT (nominal dry film thickness)
value
• Sets the statistics to display the relevant IMO PSPC values
• Identifies the batch as an IMO PSPC batch for further analysis in
the ElcoMaster™ data management software
For more information on the IMO PSPC see page 74.
For more information on ElcoMaster™ see page 35.
Fixed Batch Size (T)
When creating a new batch, by selecting Batch/New Batch and
checking the Fixed Batch Size radio button, users can pre-define the
number of readings that are to be stored into the batch (between 1 and
255) using the up and down arrow softkeys.
Once the batch has been opened and readings are being taken, the
Elcometer 456 will notify the user when the fixed batch size is
complete and ask if another batch is to be opened.
If the user selects No, then the gauge closes the batch and exits
batching - returning the gauge to the Standard (Immediate) mode.
www.elcometer.com33
en
R
DFTTECH.COM
If the user selectsYes, then the gauge automatically:
Ÿ Appends a ‘_1' to the original batch name
Ÿ Opens a new batch - copying all the batch setup and calibration
information
Ÿ The new batch is named as the original batch, with a ‘_2'
For example:
Ÿ Afixed batch is created and named “ComponentA”.
Ÿ When the batch is full, a new fixed batch ‘Component A_2’ is
created
Ÿ ‘ComponentA’becomes ‘ComponentA_1’
Appending the batch name in this way allows the user to quickly
identify - or link - similar batches together.
Once a fixed batch size batch has been filled, no additional readings
can be added to that batch; a partially completed fixed batch size
batch, however, can be re-opened and completed at a later date.
To continue a batch link, press Batch/Open Existing Batch and
select the last batch in the link. If the batch is full, the gauge will prompt
the user to open a new batch before continuing. If the batch is partially
complete the user can complete the batch before continuing to a new
batch.
When downloading linked batches into ElcoMaster™; the original
batch name will be displayed (Component A in the above example).
Selecting this batch name will download all linked batches into
ElcoMaster™ at the same time. For more information on downloading
batches see page 44.
Note: Once a fixed batch size batch has been created and data has
been stored into the memory, the user cannot rename the batch
name within the gauge. The batch name can be amended using
the ElcoMaster™ software.
www.elcometer.com 34
en
R
DFTTECH.COM
9 DOWNLOADING DATAUSING ELCOMASTER™ (BST)
Measurements from the Elcometer 456 Models B, S and T can be
downloaded to a computer using the ElcoMaster™ software (supplied with
Model S and T gauges, downloadable from the Elcometer website for
Model B gauges), or the older versions of ElcoMaster™.
This instruction book explains how users can download data using
ElcoMaster™.
Installing ElcoMaster™
To install ElcoMaster™ insert the
supplied mini-CD into your CD
ROM drive. The software will
automatically begin the install
procedure.
If it does not, or you have
downloaded the software from
the Elcometer website, run the
SetupElcoMaster2.exe file.
The ElcoMaster™ Setup Wizard
will then begin.
Follow the on screen wizard
www.elcometer.com35
en
R
DFTTECH.COM
It is important to read the License
Agreement carefully and if the
terms are acceptable, select the
‘I accept this agreement’ radio
button and click ‘Next >’
ElcoMaster™ will automatically
select a default destination
location for the software to be
installed.
Click the ‘Browse...’ button to
select an alternate file location.
Click ‘Next >’to continue
Choose any additional tasks, by
selecting the appropriate check
box and press ‘Next >’ to
continue
www.elcometer.com 36
en
R
DFTTECH.COM
The ElcoMaster™ wizard now
provides a list of the settings that
have been selected.
Click ‘Install’ to undertake the
installation or ‘< Back’ to review
or alter any settings.
ElcoMaster™ will now install.
Press ‘Finish’to exit Setup.
Upgrading data from older
version of ElcoMaster™
ElcoMaster™ is fitted with an
internal database upgrade
facility which will automatically
check to see if there are any
original ElcoMaster™ database
files and ask if the user would like
to upgrade the data to the new
ElcoMaster™ format.
Upgrading can occur at any time
by selecting Menu/Import/Import
ElcoMaster 1.x Data and
selecting the relevant database
file.
www.elcometer.com37
en
R
DFTTECH.COM
The ElcoMaster™ Software
ElcoMaster™ is a simple - yet powerful - data management software
solution that has been designed to allow users to generate
professional reports in seconds - with the minimum of fuss.
It has three operating modes; Excel Link, Standard and Advanced
Mode. ElcoMaster™ is set to Standard Mode on first install.
Across the top of the software is a Menu button, ‘Action Tabs’ and an
expand arrow.
Pressing the Menu button opens up a drop down list of options:
Ÿ Help : Provides Elcometer contact details and information
about ElcoMaster™.
Ÿ Update : Provides users with:
Ÿ the ability to update the ElcoMaster™ software
to the latest release - connection to the internet
is required for this function.
Ÿ the ability to upgrade the firmware of the:
Ÿ Elcometer 224 Digital Surface Profile
Gauge (Model B &T)
Ÿ Elcometer 456 Digital Coating Thickness
Gauge (Model B, S &T)
Ÿ Elcometer 130 Salt Contamination Meter
(Model S &T)
www.elcometer.com 38
en
R
Menu Button Action Tabs Expand Arrow
DFTTECH.COM
www.elcometer.com39
en
R
Ÿ Import: Allows users to import a database from an earlier
version of ElcoMaster™- version 1.x (not applicable
to the new Elcometer 130)
Ÿ Exit: Allows users to shut down the software
The Action Tabs available depend on the operating mode in use as
follows:
Excel Link Mode
Ÿ Settings : Allows users to adjust:
Ÿ The language of ElcoMaster™
Ÿ The units of measurement by gauge type
Ÿ Customise the default reports to include a user
logo or image, together with footer information
Ÿ Adjust the normal distribution type for the
histogram chart
Ÿ Alter the colour settings of the user interface
Ÿ The text file separator used when exporting files
Ÿ Select an alternate location to store the database
Ÿ Enable or disable the auto update option (where
access to the internet is prohibited).
Ÿ Download: Allows users to connect all their Elcometer gauges
®via USB, Bluetooth , or RS 232 where appropriate.
Standard Mode: All the features of Excel Link Mode plus;
Ÿ View: Allows users to:
Ÿ View measurement data, gauge information,
measurement statistics, set limits, add notes and
labels and view photographs and other
documents
Ÿ Print, email or PDF standard reports
Ÿ Export data to Excel or other software packages
as required
Ÿ Archive (and restore) old data
DFTTECH.COM
Ÿ SavedReports: Once a user has generated a PDF report from within
the View action tab, the report is automatically
saved within the Saved Reports action tab - for
reference and review.
Advanced Mode: All the features of Excel Link and Standard Mode
plus;
Ÿ Design custom reports
Ÿ View data in standard forms - predefined within the Design
Report action tab or by Elcometer.
Ÿ Design a collection template to guide inspectors where, and
in which order, readings should be taken - see page 46 for
further details.
Users can switch between operating modes at any time by pressing
the ExpandArrow and selecting the mode required.
en
R
www.elcometer.com 40
DFTTECH.COM
Clicking ‘Connect Gauge’ starts
t h e E l c o M a s t e r ™ G a u g e
Connect Wizard.
T h e E l c o M a s t e r ™ d a t a
management software allows
users to download readings from
a wide range of Elcometer
inspection gauges.
Measurements such as surface
profile, surface cleanliness,
temperature, dewpoint, delta T,
gloss, material thickness and dry
film thickness can all be
downloaded, stored and reported
usingtheElcoMaster™software.
These instructions will inform the
user how to download data from
an Elcometer 456 coating
thickness gauge. All appropriate
Elcometer gauges can be
downloaded in a similar way.
Ÿ Select the Dry Film Thickness
tab and press ‘Next >’
ElcoMaster™ supports the new
Elcometer 456 (identified in the
software as Elcometer 456/4)
and the Elcometer 456 Mk 3
(Elcometer 456/3).
Ÿ Select the Elcometer 456/4
tab and press ‘Next>’
Connecting an Elcometer gauge to ElcoMaster™ (BST)
In order to download any gauge readings from the Elcometer 456 the
user must first ‘Connect the gauge’ by clicking the ‘Connect Gauge’
button on the Download action tab.
www.elcometer.com41
en
R
DFTTECH.COM
Ÿ Select the appropriate
connection method for the
gauge
Elcometer 456 gauges come
supplied with Bluetooth (Models
S & T) and USB (Models B, S & T)
data output.
Users can purchase a USB
B l u e t o o t h A d a p t o r f r o m
Elcometer (Part number
T99924797) which will provide a
Bluetooth solution to computers
without internal bluetooth fitted.
If ElcoMaster™ is installed onto a
computer without Bluetooth
c a p a b i l i t y, h o w e v e r, t h e
Bluetooth tab is greyed out (as
displayed in top image).
Ÿ Select the appropriate
connection method
Ÿ Switch on the Elcometer 456
Ÿ Connect the USB cable or
make sure that Bluetooth is
switched on in the gauge via
Menu/Bluetooth/Enable
Bluetooth (S & T)
Ÿ Bluetooth users should return
their gauge to the main
r e a d i n g s c r e e n b e f o r e
continuing
Ÿ Press ‘Next >’
Ÿ A f t e r a s c r e e n p r o m p t
ElcoMaster™ will search for
and list all Elcometer 456
gauges.
en
R
www.elcometer.com 42
DFTTECH.COM
Each coating thickness gauge
connected is now listed.
Ÿ Select the appropriate gauge
and press ‘Next >’
If connecting via Bluetooth, the
gauges are identified using the
Bluetooth ID - which can be seen
o n t h e b o t t o m o f t h e
Menu/Bluetooth screen.
Connecting via Bluetooth now
requires the gauge to be ‘Paired’
by keying in the gauge’s unique
Bluetooth PIN Code. This code
can be found on the bottom of the
Menu/Bluetooth screen.
Ÿ Type in the Bluetooth PIN Code
and press ‘Next >’
(See Section 10 on page 56 for information on
connecting via Bluetooth to a mobile device
using ElcoMaster™ MobileApps.)
ElcoMaster™ will now validate the
connection, press Finish when
complete.
The gauge is now connected and
ElcoMaster™ will return the user
to the Download action tab, and
display the connected gauge.
The same gauge can be connected
by more than one method. Repeat
the ‘Connect Gauge’ and follow the
onscreenprompts.
By clicking on the Edit button, users can Delete the gauge from
ElcoMaster™, name the gauge by a more familiar identification (Enter
a User ID) or set up the gauge power up display screen (Change the
Welcome screen). See Changing the Welcome Screen on page 64.
en
R
www.elcometer.com43
DFTTECH.COM
The Download Wizard will now
guide the user through the simple
download readings process.
ElcoMaster™ allows users to
download their gauge readings:
Ÿ Directly into ElcoMaster™
Ÿ D i r e c t l y i n t o a n E x c e l
Spreadsheet, bypassing
ElcoMaster™
Ÿ into a text file for use in other
software programs, or
Ÿ into a CQATK XMLfile
Ÿ Select the appropriate option
Ÿ Select or create a new project
folder as required (ElcoMaster™
Batch File users)
Users wishing to export directly into
Excel will also be asked to select a
single or multiple spreadsheet
option. Single; all batches selected
will be downloaded into a single
spreadsheet. Multiple; each batch
will be downloaded into a separate
spreadsheet tab.
Ÿ Selectoneormoreindividualbatches
orclickon‘AllFiles’andpress‘Next>’
Downloading Data from the Elcometer 456 (ST)
Once the gauge has been connected to ElcoMaster™ (see pages
41-43), switch on your gauge and click the ‘Download from Gauge’
button for the relevant gauge and connection method.
When downloading data into ElcoMaster™ (as opposed to directly into a
spreadsheet or a text file), downloaded data is stored in Projects - allowing
users to clearly identify inspections.
en
R
www.elcometer.com 44
DFTTECH.COM
The User will be asked to select a
project name from the list.
Alternatively the user can create
a New Project name.
Ÿ Select or create a new project
and press ‘Next >’
To download readings from the
gauge:
Ÿ Select a single or multiple
batches from the list or click on
‘All Files’ as required, then
press ‘Next >’
Ÿ Select or create a new folder
to save the gauge’s data to
In some cases users may have
re-used an existing batch name
in the gauge. The user should
now chose either to select:
Ÿ Rename Duplicate Files
Ÿ RenameAll Files, or
Ÿ Overwrite Existing Files
Ÿ Select as required and press
‘Next >’
The selected batches will now
download. Once the data
download has been completed,
the user can check the ‘View
Files’box and click ‘Finish’.
Alternatively, click ‘Finish’ and
select the ‘ViewActionTab’
en
R
www.elcometer.com45
DFTTECH.COM
Viewing Data in ElcoMaster™
ElcoMaster™ not only allows users to view and analyse data from a
wide range of Elcometer gauges, but also allows users to manually
input data as required.
This instruction book provides a brief summary of some of the features
of ElcoMaster™, however users should read the ElcoMaster™ help
file for a complete guide.
Data Tree Command Tabs Template Tabs
Live Reading Tab Measurement Data Window Graph Window
en
R
www.elcometer.com 46
DFTTECH.COM
By selecting the View Action Tab, users can instantly see their data.
The ViewActionTab can be broken down into 6 distinct areas:
Ÿ Data Tree Batches can be stored within folders ( ) in unique
Project files ( ).
By clicking on the Project filename, users can then
completeuniqueprojecttagsandbatchtagsasrequired.
Eachbatchofdataisidentifiedbythetypeofinspection:
Climate Batch
Surface Profile Batch
Surface Cleanliness Batch
Dry FilmThickness Batch
Material / Ultrasonic NDTBatch
Clicking the computer mouse’s right button over a file
orfolderprovidestheuserwiththefollowingfunctions:
Ÿ New:
Allows users to:
Ÿ create a new Project ( )
Ÿ create a new Folder ( )
Ÿ import an Image ( )
Ÿ import a PDF Document ( )
Ÿ create a new batch type
Ÿ Cut, Copy & Paste:
Cut, copy & paste inspection files and folders
into other files or folders within the data tree.
Ÿ Delete, rename & move to:
Allows delete, rename or move a file
Ÿ Combine & Split:
Combine batches of the same type or split a
batch into equal sizes or of equal time
Ÿ Archive & Restore:
Archive and restore inspection data
Ÿ Print, PDF, Email & Export:
Print, generate a PDF or export to Excel or a tab
separated text file; the selected batch report
en
R
www.elcometer.com47
DFTTECH.COM
Ÿ Command Tabs
There are 6 command tabs, which are the key
functions required by the user.
Ÿ New:
Allows users to:
Ÿ create a new Project ( )
Ÿ create a new Folder ( )
Ÿ import an Image ( )
Ÿ import a PDF, .edf, .txt. Document ( )
Ÿ create a new batch type
Ÿ Move to:
Moves the selected items to a different folder or
to a different page
Ÿ Print:
Prints a report of the selected items
Ÿ PDF:
Generates a PDF report of the selected items
Ÿ Email:
Generates a PDF report of the selected items
and attaches it to an email
Ÿ Export:
Ÿ Allows the user to export the selected items into
Excel or as a text or CQATK XMLfile
en
R
www.elcometer.com 48
DFTTECH.COM
Ÿ Template Tabs & Graph Window
There are currently 2 graphs within ElcoMaster™;
individuals and histogram. Clicking a template tab
displays the relevant graph in the Graph Window
When the Individuals Graph is displaying climate
data, additional tabs appear on the right hand side,
allowing the user to select a measurement to view
from the following:
RH: Relative Humidity
Ts: SurfaceTemperature
Ta: AirTemperature
Td: DewpointTemperature
TΔ: DeltaT, (Ts-Td)
Tdb: Dry BulbTemperature
Twb: Wet bulbTemperature
SH: Specific Humidity
Right mouse click on the individuals graph allows
users to select the x-axis value between:
Date &Time RelativeTime (seconds)
Reading Number RelativeTime (minutes)
Left clicking and dragging the mouse across the
individuals chart allows users to zoom in on a
specific area of the graph. The zoom can be reset by
clicking on the icon.
en
R
www.elcometer.com49
DFTTECH.COM
Ÿ Measurement Data Window
The measurement data window provides the user with a
range of information under 7 tabs:
Ÿ Details
Provides useful information about the measurement gauge,
serial number, batch name, date the batch was created, date
and time of the first and last reading, etc.
Ÿ Statistics
Provides the user with a wide range of statisitical
calculations - mean, minimum and maximum reading,
standard deviation, ±3σ, coefficient of variation, relevant
information regarding the IMO PSPC analysis (coating
thickness gauge readings only).
Users can display the values on the graph by clicking the
( ) icon and selecting a colour.
Ÿ Measurements
Displays all the individual readings. Users can alter the
display order (Date & Time, Relative Time (seconds),
Relative Time (minutes) and Reading Number) by clicking on
the column title.
Individual measurements can be excluded/ included by right
clicking on the specific measurement within the table.
Measurements can also be amended by overtyping the
relevant reading.
Comments can be added to any measurement by clicking
on, and then typing into, the relevant cell within the
comments column.
Ÿ Limits
Shows any limits that were used whilst taking the readings or
allows users to apply limits. When set, measurements
outside the limits are highlighted within the measurement
tab.
Users can display the values on the graph by clicking the
( ) icon and selecting a colour.
en
R
www.elcometer.com 50
DFTTECH.COM
Ÿ Measurement Data Window (continued)
Ÿ Notes
Type and format a comment or note regarding the batch.
Ÿ Labels
When a project has been set up with individual Project and
Batch labels users can amend or input the appropriate
details. Project labels are applied to each file, folder and
batch within the project; Batch labels apply to a specific
batch. Both project and batch labels are fully user definable,
however examples of project and batch labels are listed
below:
Project Label Examples:
Client name, Structure name, Structure location,
Batch Label Examples:
Inspector name, shift number, area under
consideration, strutt number, etc.
Ÿ Photos
Photographs of the area under inspection, specific defects,
etc can be attached to the measurement batch - simply by
clicking the ( ) icon within the Photos tab.
Descriptions or comments can be added below each image
added.
Double clicking on any photo opens up a view window
allowing the user to copy the photo to clipboard (for pasting in
another program, or save the photograph to another file.
Data, photographs, labels etc. added within the measurement
window tabs is automatically included on any reports, exports, pdf
and emails generated.
en
R
www.elcometer.com51
DFTTECH.COM
Ÿ Live Gauge Readings (BST)
ElcoMaster™ allows users to transfer data from a gauge as the
readings are taken, to be stored in a batch within ElcoMaster™.
Live gauge readings can be recorded via Bluetooth (ST) or USB
(BST) connections
Once the gauge has been connected
to ElcoMaster™ (see pages 41-43),
switch on your gauge and click the
‘Live Readings’ button on the View
ActionTab
Ÿ Select the appropriate batch (or
create a new batch) for the
readings to be recorded into
ElcoMaster™ will now open up the
Live Readings display, and ask the
user to ‘ Connect Gauge’
Ÿ Click on the Connect Gauge
Ÿ Select a gauge from the list
Ÿ Select the relevant connection
method (if more than one
connection method has been set
up (see pages 41-43)
ElcoMaster™ will then link with the
selected gauge and, when ready
display the gauge information within
the Live Readings window.
Ÿ At any time the user can select a
different batch to change where
the next reading is taken.
Ÿ Click the button or switch
of the gauge to disconnect
en
R
www.elcometer.com 52
DFTTECH.COM
Ÿ Click on the Design Collect tab and
select an existing template or click
‘New Design’
When creating a new design you will
be asked to:
- Enter a name and description
- Select the Batch Type; Profile,
Material Thickness, DFT or Surface
Cleanliness
- Add the required image to collect
readings against
- Specify the number of readings to be
collected
- Enter relevant Limits
- Request a prompt to begin the next set
of readings or begin automatically
- Choose to create a new batch for each
set of readings or create a single batch
with multiple reading sets
Ÿ Click ‘Finish’to begin the design
To design the ‘collect’ image sequence,
simply click and hold each 'reading'
circle in turn, drag onto the image where
readings are to be taken and adjust the
size accordingly.
Once complete click ‘Save’ and click the
'X' button in the top right to close the
design window.
Ÿ Design Collect
The ‘Design Collect’ function allows users to set up a collection
template to guide Inspectors where, and in which order, readings
should be taken. This image can be used as a collection guide in
‡
ElcoMaster™ or transferred to an Android mobile phone or tablet
using ElcoMaster™ forAndroid™, see pages 55 - 56.
‡
To use Design Collect, switch ElcoMaster™ to Advanced Mode by clicking on the Expand Arrow, and
selecting ‘StartAdvanced Mode’.
www.elcometer.com53
en
R
DFTTECH.COM
Using a Collect Design
Ÿ Select the ‘View’tab
Ÿ Select a folder or project and click
the ‘New’button
Ÿ Move the cursor to relevant batch
type, an additional window will
appear, select the required Collect
Design
A new batch will be created. Unlike
standard batches it will have an
additional tab with the same name as
the Collect Design, click on this to show
your design.To begin collection,
Ÿ Click on ‘Connect Gauge’in the ‘Live
Readings’window
a
Ÿ Select a gauge from the list
Ÿ Select the relevant connection
method
ElcoMaster™ will link the selected
gauge and, when ready, display the
gauge information within the Live
Readings window.
Once connected, green arrows will
flash around the first ‘reading’ circle to
measure. When a measurement is
taken, the ‘reading’ circle will change to
b
show the measured value , and the
green arrows will move to the next
reading.
a
The gauge must be connected to ElcoMaster™ before it will appear in the list, see pages 41 - 43.
b
The ‘reading’circle will be green if the measurement is within set limits and red, if outside limits.
en
R
www.elcometer.com 54
DFTTECH.COM
10 ELCOMASTER MOBILEAPPS (ST)
Ideal when out in the field or on-site, live readings can be stored directly
onto a mobile device and saved into batches. Inspection data can be
transferred from mobile to PC for further analysis and reporting.
ElcoMaster™ MobileApps features include:
Ÿ Store live readings directly on to a mobile device and save into
batches.
Ÿ Download batches straight to a mobile device allowing data analysis
immediately on site.
Ÿ Transfer inspection data to PC for further analysis and reporting.
Ÿ Analyse data via sequential readings, statistics, charts & histograms
or on images.
Ÿ Download collection images created using the 'Design Collect'
function within ElcoMaster™ to indicate where and in which order
readings should be taken.
Ÿ Take photographs and add them to batch readings at the click of a
button.
Ÿ Map readings on to maps, photographs or diagrams.
en
R
www.elcometer.com55
DFTTECH.COM
en
R
www.elcometer.com 56
Connecting via Bluetooth to a Mobile Device
To use ElcoMaster™ Mobile Apps, the Elcometer 456 gauge must be
'paired' with mobile device via Bluetooth:
1. Switch on the Elcometer 456 and ensure that Bluetooth is enabled via
Menu/Bluetooth/Enable Bluetooth. Return the gauge to the main
reading screen before continuing.
2. Switch on the mobile device and enable Bluetooth (usually via 'Settings'
– refer to the operating instructions for the mobile device).
3. The mobile device will search for and list all Elcometer 456 gauges
with Bluetooth enabled. Each gauge is identified as “E-456/4“
followed by the serial number.
4. Select the Elcometer 456 gauge required. The mobile device now
will attempt to 'pair' with the selected gauge.
5. A 'Bluetooth' pairing request will appear on both the mobile device
and gauge. Accept the pairing request on both.
The mobile device and Elcometer 456 gauge are now 'paired'.
Compatible with smart phones and tablets
running Android 2.1 or above. To install,
download via www.elcometer.com or using
the Google Play™ Store app, and follow the
on screen instructions.
Made for iPhone 6 Plus, iPhone 6, iPhone 5s,
iPhone 5c, iPhone 5, iPhone 4s, iPhone 4,
iPad Air 2, iPad mini 3, iPad Air, iPad mini 2,
iPad (3rd and 4th generation), iPad mini,
iPad 2, and iPod touch (4th and 5th
generation). To install, download via
www.elcometer.com or the App Store, and
follow the on screen instructions.
DFTTECH.COM
11 CLOUD COMPUTING WITH ELCOMASTER (ST)
ElcoMaster™ is now compatible with Cloud Computing.
Ÿ Create a Cloud account via a Cloud service provider e.g.
Dropbox, Google Drive™, Skydrive or your own cloud based
FTP server.
Ÿ All approved users of the cloud account will have instant access
to all inspection data in real time.
Ÿ Data can be accessed by authorised users via secure log-in
from any computer or mobile device anywhere in the world via
®Bluetooth , USB, WiFI or 3G/4G.
Ÿ Using the ElcoMaster™ instant messaging feature, job
instructions can be sent or stored in specific job files.
Ÿ Wherever you are in the world, ElcoMaster™ Mobile allows you
to instantly upload to the cloud via 3G/4G or WiFi.
en
R
www.elcometer.com57
DFTTECH.COM
12 GETTING THE MOST OUT OF ELCOMASTER
ElcoMaster™ has been designed to be a very intuitive method of developing
professionalreports,itishoweverextremelyversatile.Herearejustafewways
ElcoMaster™canbeusedintheday-to-dayactivitiesofacoatingprofessional.
1. Gauge to PC to Excel
Transferring inspection data straight
into Microsoft Excel via Bluetooth® or
USB is simple and easy.
4. Upload to a cloud for real time
analysis anywhere
Using ElcoMaster™ Mobile App you can
upload inspection data, photos, notes
and GPS coordinates direct to a Cloud
account of your choice via 3G/4G or
WiFi.
All data is instantly visible to other
approved users of the account - through
a secure log-in on any computer or
mobile device anywhere in the world.
2. Gauge to PC data transfer into
ElcoMaster™
®
Using Bluetooth or USB, ElcoMaster™
transfers inspection data in seconds,
archiving data and generating reports at
the click of a button.
3. ElcoMaster™ Mobile App for
immediate data transfer from site
to office
Transfer inspection data straight to
®
mobiles and tablets via Bluetooth
when on site for instant analysis, then
e-mail them back to the office for
storing, review and QA reporting.
5. Seamlessly link multiple sites or
production lines
ElcoMaster™ gives you real time quality
control monitoring from multiple inspection
projects in any location. You can compare
and combine inspection data from
different production lines or different
locations, to produce specific Project
Inspection Reports quickly and easily.
en
R
www.elcometer.com 58
DFTTECH.COM
12 GETTING THE MOST OUT OF ELCOMASTER
Real time collaboration for multi-site
projects
When working with manufacturers of
sub-assemblies across the globe
ElcoMaster™ can collate all inspection
data from each site, assembly line and
project into one shared location.
Contractors can then:
Ÿ Accept or reject parts before
shipment from sub-assembly plants.
Ÿ Combine all data from sub
assembly and final assembly
inspection to generate Project
Inspection Reports for quality
management, both during and after
completion of the project.
Ÿ Have real time in progress visibility
across the whole project, no matter
where the sub-assembly
manufacturing is in the world.
Ÿ Have multi-site collaboration, real
time dialogue and decision making
to improve efficiency and quality
throughout the production process.
Real time communication
Featuring instant messaging the
ElcoMaster™ Mobile App lets you
add messages to inspection data,
projects and files, allowing you to
immediately discuss key points with
your colleagues, managers or clients,
send work instructions and store
messages within the project file.
Your data - your choice - your control
ElcoMaster™ allows you to decide
which Cloud service provider to use.
It is your data, it is secure as only
approved users can have access, no
third parties can see your data.
ElcoMaster™ Mobile App is
compatible with a range of cloud
service providers and FTP servers
including: Google Drive, FTP Server,
Dropbox.
6. Real time collaboration for multi-site projects
en
R
www.elcometer.com59
DFTTECH.COM
13 CALIBRATING THE ELCOMETER 456 (EBST)
The Elcometer 456 gauge is available in 4 model versions. Each version
has a number of calibration methods as below:
For full descriptions of each calibration method please see page 19- 20.
The Elcometer 456 has on screen instructions to guide the user through
each calibration method.
Method Model E Model B Model S Model T
Factory ■ ■ ■ ■
Rough / 2 Point ■ ■ ■ ■
Zero ■ ■ ■
Smooth ■ ■ ■
Zero Offset ■ ■
Auto ■ ■
Calibrating the Elcometer 456 (Model E)
Press the Cal softkey and follow the on screen instructions.
a b c d
e
h g f
en
R
www.elcometer.com 60
DFTTECH.COM
To calibrate the Elcometer 456 Model E on rough surfaces:
Ÿ Select two foil values - one above the target dry film thickness value
(thick) and one below (thin)
Ÿ Follow the on screen instructions
Ÿ more than one reading can be taken on each foil value - the average
of the readings is displayed (screens c and g on page 60).
Ÿ To calibrate the Elcometer 456 Model E on smooth surfaces:
Ÿ Select a foil value which is above the target dry film thickness value
(thick) and the uncoated base substrate (thin).
Ÿ When the gauge instructs the user to place the gauge onto the thin foil
(calibration step 2), place the probe on the uncoated base and adjust
the thickness value to 0.0µm (mils)
To calibrate the Elcometer 456 Model E using the Factory calibration:
Ÿ Select either Menu/Reset/Metric Gauge or Menu/Reset/Imperial
Gauge.
Taking multiple readings on each foil will increase the accuracy of the
calibration.
Calibrating the Elcometer 456 (BST)
Ÿ Press the Cal softkey to open the Calibration
menu
Ÿ As the Elcometer 456 Model B, S and T have
multiple calibration methods;
Ÿ if the Calibration Method icon displayed is
as required, press the Select softkey and
follow the on screen instructions
Ÿ the user can amend the calibration method,
by selecting the appropriate method from
within the Cal/Cal Method menu and press
the Select softkey before selecting
Calibrate from the Calibration menu
en
R
www.elcometer.com61
DFTTECH.COM
Ÿ to select the factory calibration press
Cal/Factory Calibration
Ÿ The factory calibration returns the gauge to
the calibration set up during manufacture
and final test. The factory calibration is a
smooth surface calibration using factory
reference probes
Ÿ When the correct calibration method has been
selected, press Cal/Calibrate and follow the on
screen instructions.
Ÿ Taking multiple readings on each foil will
increase the accuracy of the calibration.
Note: Auto, ISO, SSPC PA2, Swedish and
Australian cal methods - where available -
can only be selected whilst in batching as
memory is required.
Testing (BST) & Validating (ST) Calibrations
Ÿ The calibration of any Elcometer 456 B, S
or T gauge can be checked at any time,
without affecting any statistics or batch
memory.
Ÿ By selecting Cal/Test Calibration the user
can check the calibration of the gauge by
comparing the reading value displayed
versus the measured foil or coated
standard value. (ST)
Ÿ Pressing the Validate Softkey will update
the date and time of the last calibration.
(ST)
Each batch can have its own unique calibration,
simply calibrate each batch independently.
For more information on Batching see page 23.
en
R
www.elcometer.com 62
DFTTECH.COM
Calibration lock (BST)
To avoid accidental amendments to the calibration settings switching
on the Cal/Calibration Lock feature’ locks’ the user from undertaking
any changes to the calibration without first un-checking the
Cal/Calibration Lock feature.
When the Calibration Lock is enabled, users can still test the
calibration via Cal/Test Calibration but will be unable to validate or
re-calibrate the gauge.
The calibration can also be locked using a PIN Code.
Locking & Unlocking the Calibration Lock using a PIN Code (BST)
To unlock the calibration:
Ÿ Press the Cal softkey and select Calibration Lock
éŸ Enter the four digit PIN Code, if set, using the softkeys to selectê †
0 to 9 and the è softkey to move from the first to the fourth digit
Ÿ Press Ok or Escape to cancel
To disable the calibration lock PIN Code:
Ÿ Press the Menu softkey and select Setup/Calibration Lock
Ÿ Enter the four digit PIN Code
4 Should the user forget or loose the PIN code, the PIN can be
disabled via ElcoMaster™. Using the USB cable, simply connect the
gauge to a PC with ElcoMaster™ Version 2.0.34 or higher installed
and select Edit/Clear Calibration PIN.
†
The è softkey will appear when the “ X “ changes to a number.
To set a calibration lock PIN code:
Ÿ Press the Menu softkey and select
Setup/Calibration Lock
éŸ Set the four digit PIN Code using the ê
softkeys to select 0 to 9 and the è softkey to
†
move from the first to the fourth digit
Ÿ Press Set, Escape to cancel or Adjust to amend
the PIN code
en
R
www.elcometer.com63
DFTTECH.COM
14 CHANGING THE WELCOME SCREEN (BST)
Each time the Elcometer 456 gauge is switched on, the Elcometer logo is
displayed. Users can add their own logo, image or identification details as
required via ElcoMaster™.
Once the gauge has been connected
to ElcoMaster™ (see pages 41-43),
to add a user welcome screen
Ÿ Switch on your gauge
Ÿ Select the DownloadActionTab
Ÿ Click the ‘Edit’ button on the right
hand side of the appropriate
gauge
Ÿ Select ‘Change Welcome Screen’
from the drop down menu
Ÿ Select the required image, and or
add user specific text and press
‘Next >’
Ÿ Select ‘Stretch Image’ or ‘Centre
Image’ as required and press
‘Next >’
Ÿ Select the appropriate connection
method and press ‘Next >’
ElcoMaster™ will now download the
selected image into the gauge. This
may take some time.
en
R
www.elcometer.com 64
DFTTECH.COM
15 GAUGE FIRMWARE UPDATES (BST)
Each time the Elcometer 456 gauge is connected to ElcoMaster™ (see
pages 41-43); if the computer has access to the internet, ElcoMaster™
automatically checks to see if there are any gauge firmware updates for
the connected gauge.
ElcoMaster™ will inform the user when
there are any firmware updates available
for the connected gauge by displaying
the ‘Update Gauge’button.
Please note that users can update the
gauge firmware via a USB connection
only .
Clicking the ‘Update Gauge’ button will
display a list of the ‘Fixes’ in all the
updates that have been released since
the gauge’s last upgrade.
Ÿ Press ‘Next >’to continue.
Warning - updating the gauge firmware
will result in all readings, batches,
statistics and calibrations being deleted.
The gauge will also be returned to the
factory default settings.
Ÿ Press ‘Next >’ to commence
downloading the latest firmware to the
Elcometer 456
Warning - Do not switch off the computer
or disconnect the gauge during the
gauge upgrade.
Typical firmware updates include gauge enhancements, amendments,
language updates, etc. Users cannot upgrade a Model B to a Model S for
example, nor can a ferrous gauge be upgraded to a dual ferrous/non-
ferrous gauge.
en
R
www.elcometer.com65
DFTTECH.COM
16 GAUGE ICONS & ERROR CODES (EBST)
Icon Description Model
Number of Readings BST
Mean (average) BST
Standard Deviation BST
Highest Reading BST
Lowest Reading BST
Coefficient of Variation BST
Elcometer Index Value (EIV) BST
NDFT Value (Nominal Dry Film Thickness) ST
Percentage of readings greater than or equal to the
NDFT Value ST
Percentage of readings between 0.9 x NDFT and the
NDFT value ST
90/10 Rule Pass ST
90/10 Rule Fail: 90% of readings are greater than the
NDFT value ST
90/10 Rule Fail: At least one measurement is below 0.9
x NDFT. (If a number between 1 and 10 is displayed, insufficient
measurements have been taken to be statistically valid)
ST
Counted Average (when not in Batching) BST
High and Low Limit Set ST
Low Limit Set ST
High Limit Set ST
Number of readings above Limit ST
Number of readings below Limit ST
en
R
www.elcometer.com 66
DFTTECH.COM
Icon Description Model
Zero Calibration Method BST
Smooth Surface Calibration Method BST
Rough/ 2 Point Calibration Method EBST
Zero Offset Calibration Method ST
Auto Calibration Method ST
ISO 19840 Calibration Method ST
SSPC PA2 Calibration Method ST
Swedish Standards Calibration Method ST
Australian Standards Calibration Method ST
Calibration Check T
Reading outside Calibration T
Calibration Lock BST
Calibration
Icon Description Model
Low Limit Set: Reading outside Low Limit ST
High Limit Set: Reading outside High Limit ST
Low & High Limit Set: Reading outside Low Limit ST
Low & High Limit Set: Reading outside High Limit ST
en
R
www.elcometer.com67
DFTTECH.COM
Icon Description Model
Auto Repeat Mode T
Scan Mode T
Scan Mode with Hold T
Icon Description Model
Bluetooth Not Connected ST
Bluetooth Connected ST
USB Connected BST
Ferrous Probe on Ferrous Substrate EBST
Non-Ferrous Probe on Non-Ferrous Substrate BST
Dual FNF Probe on Ferrous Substrate EBST
Dual FNF Probe on Non-Ferrous Substrate EBST
Battery Life Indicator EBST
Replace Batteries EBST
User Selectable Feature: Switched Off EBST
User Selectable Feature: Switched On EBST
Beep Volume Setting EBST
General
Icon Description Model
Batch Type: Normal ST
Batch Type: Counted Average ST
Batch Type: IMO PSPC ST
Deleted Reading - Tagged ST
Batching
en
R
www.elcometer.com 68
Measurement Modes
DFTTECH.COM
Message Cause / Action
#1 - Probe Probe to gauge communication failure.
Integral Gauges: Contact Elcometer.
Separate Gauges: Remove probe and refit. If error
persists, contact Elcometer.
#2 - Probe Corrupt data output from probe.
Integral Gauges: Contact Elcometer.
Separate Gauges: Replace probe. If error persists,
contact Elcometer.
#3 - Probe Internal Error - contact Elcometer.
Probe Unsupported No probe connected. Connect probe.
Probe is Dual FNF but gauge is ferrous or non-ferrous
only or Mk 3 probe is being used with a Mk 4 gauge.
Use correct probe.
Probe Changed Probe has been changed during a calibration
procedures. Calibration adjustment required.
Unstable Reading External electromagnetic interference or gauge is faulty.
Isolate from electromagnetic interference. If error
persists, contact Elcometer.
Value Too Large Calculated value is too large to be displayed. Contact
Elcometer.
Calibration Error Incorrect calibration calculation. Re-calibrate. If error
persists, contact Elcometer.
Bluetooth PC Reply Bluetooth link working at limit of its range. PC is busy
running other applications. Interference. PC
application doesn’t send replies. Move gauge closer to
PC. Shutdown other applications. Remove source of
interference. If error persists, contact Elcometer.
Error - EEPROM Write Gauge EEPROM communication error.
If problem persists, EEPROM is faulty.
Error Codes
Under certain conditions, the gauge will display error messages. These
message are cleared by pressing any key. The cause of the error should
be corrected before proceeding.
en
R
www.elcometer.com69
DFTTECH.COM
TimeandDate
SetTime
SetDate
SetFormat
DisplayTimeandDate
17 GAUGE MENU STRUCTURES (EBST)
Please find below a simplified diagram of each Elcometer 456 model’s
menu structures.
Elcometer 456 Model T
MeasurementMode
StandardMode
AutoRepeatMode
ScanMode
ScanModeWithHold
Setup
Units
Language
TimeandDate
BeepVolume
ScreenSettings
Probe
MeasurementMode
GaugeAutoOff
CalibrationLock
NAVSEAScreenSettings
ScreenBrightness
ScreenTimeout
AutoDisplayRotation
OpeningScreen
SetLimits
EnableLimits
SetUpper
SetLower
SetNDFT
Bluetooth
EnableBluetooth
BluetoothIDxxxxxx
BluetoothCodexxxxxx
AI
About
GaugeInformation
ProbeInformation
Contact
Legal
BatchLimits
EnableLimits
SetUpper
SetLower
SetNDFT
BatchType
Normal
CountedAverage
IMOPSPC
BatchCalibration
Calibrate
CalMethod
UseCalMemory1
UseCalMemory2
UseCalMemory3
DeletedReading
DeleteWithTag
DeleteWithoutTag
NewBatch
OpenBatch1
RenameBatch1
BatchCalibration
BatchType
BatchLimits
FixedBatchSize
NAVSEA
Menu
DeleteLastReading
Setup
SetLimits
Bluetooth
About
Reset
EmergencyLight
Calibration
Calibrate
CalMethod
CalMemory1
CalMemory2
CalMemory3
FactoryCalibration
CalibrationLock
TestCalibration
CalibrationCheck
Batch
MemoryFree
NewBatch
OpenExistingBatch
ExitBatching
EditBatch
CopyBatch
ReviewBatch
DeletedReading
Display
ClearStatistics
ReadingsOnly
Readings&SelectedStats
Readings&RunChart
Readings&BarGraph
BatchGraph
Statistics
○
ReviewBatch
Batch1
Statistics
BatchInformation
CalibrationInformation
Readings
BatchGraph
CalibrationLock
EnablePIN
Units
µm
mm
mils
inch
Statistics
ClearStatistics
ViewSelected
ViewAll
SelectStatistics
CountedAverage
EditBatch
RenameBatch
ClearBatch
DeleteBatch
†
Probe
AutoFNF
FerrousF
NonFerrousN
ProbeSwitchOn
†
Probe
FerrousF1
FerrousF2
Legal
Patents
LegalNotices
Regulatory
CalMethod
Zero
Smooth
Rough/2Point
ZeroOffset
Auto
ISO
SSPCPA2
Swedish
Australian
○
○
○
○
○
○
CalMethod
Zero
Smooth
Rough/2Point
ZeroOffset
Auto
CalMemoryn
Savedhh:mmdd/mm/yy
Select
Calibrate
CalMethod
TestCalibration
RenameCalMemoryn
ViewCalibrationData
ClearCalMemoryn
wheren=1,2,or3
○
○
○
○
SelectStatistics
AllPSPCValues
NumberofReadings
Mean
LowestReading
HighestReading
StandardDeviation
CoefficientofVariation
LowLimitValue
NumberBelowLimit
HighLimitValue
NumberAboveLimit
ElcometerIndexValue
NDFTValue
%>=NDFT
%90-100%NDFT
IMO90:10Pass/Fail
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
†
Menu displayed is dependent on
the probe connected
en
R
www.elcometer.com 70
Regulatory
QDIDxxxxxx
xxxxxx
xxxxxx
xxxxxx
○
○
DFTTECH.COM
17 GAUGE MENU STRUCTURES CONTINUED (EBST)
Elcometer 456 Model S
TimeandDate
SetTime
SetDate
SetFormat
DisplayTimeandDate
Setup
Units
Language
TimeandDate
BeepVolume
ScreenSettings
Probe
GaugeAutoOff
CalibrationLock
ScreenSettings
ScreenBrightness
ScreenTimeout
AutoDisplayRotation
OpeningScreen
SetLimits
EnableLimits
SetUpper
SetLower
SetNDFT
Bluetooth
EnableBluetooth
BluetoothIDxxxxxx
BluetoothCodexxxxxx
AI
About
GaugeInformation
ProbeInformation
Contact
Legal
BatchType
Normal
CountedAverage
IMOPSPC
BatchCalibration
Calibrate
CalMethod
DeletedReading
DeleteWithTag
DeleteWithoutTag
NewBatch
OpenBatch1
BatchCalibration
BatchType
Menu
DeleteLastReading
Setup
SetLimits
Bluetooth
About
Reset
EmergencyLight
Calibration
Calibrate
CalMethod
FactoryCalibration
CalibrationLock
TestCalibration
Batch
MemoryFree
NewBatch
OpenExistingBatch
ExitBatching
EditBatch
ReviewBatch
DeletedReading
Display
ClearStatistics
ReadingsOnly
Readings&SelectedStats
Readings&RunChart
Readings&BarGraph
Statistics
○
ReviewBatch
Batch1
Statistics
BatchInformation
CalibrationInformation
Readings
CalibrationLock
EnablePIN
Units
µm
mm
mils
inch
Statistics
ClearStatistics
ViewSelected
ViewAll
SelectStatistics
CountedAverage
EditBatch
ClearBatch
DeleteBatch
†
Probe
AutoFNF
FerrousF
NonFerrousN
ProbeSwitchOn
†
Probe
FerrousF1
FerrousF2
Legal
Patents
LegalNotices
Regulatory
CalMethod
Zero
Smooth
Rough/2Point
ZeroOffset
Auto
ISO
SSPCPA2
Swedish
Australian
○
○
○
○
○
○
CalMethod
Zero
Smooth
Rough/2Point
ZeroOffset
Auto
○
○
○
SelectStatistics
AllPSPCValues
NumberofReadings
Mean
LowestReading
HighestReading
StandardDeviation
CoefficientofVariation
LowLimitValue
NumberBelowLimit
HighLimitValue
NumberAboveLimit
ElcometerIndexValue
NDFTValue
%>=NDFT
%90-100%NDFT
IMO90:10Pass/Fail
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
†
Menu displayed is dependent on
the probe connected
en
R
www.elcometer.com71
Regulatory
QDIDxxxxxx
xxxxxx
xxxxxx
xxxxxx
DFTTECH.COM
17 GAUGE MENU STRUCTURES CONTINUED (EBST)
Elcometer 456 Model B
Display
ClearStatistics
ReadingsOnly
Readings&SelectedStats
Readings&BarGraph
Statistics
†
Probe
AutoFNF
FerrousF
NonFerrousN
ProbeSwitchOn
†
Probe
FerrousF1
FerrousF2
○
○
○
○
○
○
Setup
Units
Language
BeepVolume
ScreenSettings
Probe
GaugeAutoOff
CalibrationLock
ScreenSettings
ScreenBrightness
ScreenTimeout
AutoDisplayRotation
OpeningScreen
About
GaugeInformation
ProbeInformation
Contact
Legal
CalMethod
Zero
Smooth
Rough/2Point
○
○
○
○
○
○
○
○
○
○
Menu
DeleteLastReading
Setup
About
Reset
EmergencyLight
Calibration
Calibrate
CalMethod
FactoryCalibration
CalibrationLock○
Data
LastFiveReadings
50.5µm
52.3µm
51.0µm
51.8µm
51.5µm
EscapeDeleteOk
○
○
○
○
○
○
SelectStatistics
NumberofReadings
Mean
LowestReading
HighestReading
StandardDeviation
CoefficientofVariation
ElcometerIndexValue
CalibrationLock
EnablePIN
Units
µm
mm
mils
inch
○
○
○
○
Legal
Patents
LegalNotices
Regulatory
Statistics
ClearStatistics
ViewSelected
ViewAll
SelectStatistics
CountedAverage
†
Menu displayed is dependent on
the probe connected
en
R
www.elcometer.com 72
Regulatory
xxxxx
DFTTECH.COM
17 GAUGE MENU STRUCTURES CONTINUED (EBST)
Elcometer 456 Model E
Setup
Units
Language
Beep Volume
Screen Settings
Probe Switch On
Units
µm
mm
mils
inch
About
Gauge Information
Probe Information
Contact
Legal
Menu
Setup
About
Reset
Calibration
Pressing the Cal Softkey
starts the calibration process
Screen Settings
Screen Brightness
ScreenTimeout
○
Legal
Patents
Legal Notices
Regulatory
en
R
www.elcometer.com73
Regulatory
xxxxx
DFTTECH.COM
18ABOUT IMO PSPC (ST)
The Elcometer 456 is capable of
displaying PSPC readings
according to the 90/10 rule as
defined in the International
Maritime Organisation (IMO)
requirements.
To pass the 90/10 rule:
At least 90% of all thickness
measurements shall be greater
than or equal to the NDFT value
and;
N o n e o f t h e r e m a i n i n g
measurements shall be below 0.9
x NDFT.
To PASS 90/10
At least 90% of
all readings must
be in this zone...
90/10 FAILED if
Less than 90% of
all readings are in
this zone...
... no readings
must be in this
zone
... any readings
are in this zone
AND OR
SUBSTRATE
COATING
0.9 x NDFT
NDFT
While you are taking readings with PSPC selected, your gauge will advise
you whether the readings are passing or failing the rule:
Ÿ When the PSPC statistics are in the passing state, the reading
value is white and the green LED flashes;
Ÿ When the PSPC statistics are in the percent fail state, the reading
value is white and both the red and green LEDs flash;
Ÿ When the PSPC statistics are in the reading fail state, the reading
value is red and the red LED flashes.
Note: The default value for NDFT is 320µm (12.6mils) - from PSPC for Ballast Water
Tanks.
Note: The 90/10 rule is not compatible with the counted average data collection method
(see Batching on page 26) and cannot be used when saving readings using this method.
en
R
www.elcometer.com 74
DFTTECH.COM
19 GAUGE TECHNICALSPECIFICATIONS (EBST)
Display Information 60mm (2.4") QVGA colour TFT display, 320 x 240 pixels
Battery Type 2 x AA dry cell batteries, rechargeable batteries can also be used
Battery Life ~24 hours of continuous use at 1 reading per second
Using default settings & lithium batteries, alkaline or rechargeable batteries
may differ
Gauge Dimensions
(h x w x d)
Integral: 141 x 73 x 37mm (5.55 x 2.87 x 1.46")
Separate: 141 x 73 x 37mm (5.55 x 2.87 x 1.46")
Gauge Weight
(including supplied batteries)
Integral: 156g (5.5oz)
Separate: 161g (5.68oz)
Operating Temperature -10 to 50°C (14 to 122°F)
73mm (2.87")
141mm(5.55")
60mm
(2.4")
37mm (1.46")
en
R
www.elcometer.com75
DFTTECH.COM
20 PROBE TECHNICALSPECIFICATIONS (EBST)
Available in a number of designs and scale ranges, all probes are supplied with an
Elcometer test certificate and a set of calibration foils appropriate to the scale range.
Ferrous probes measure non magnetic coatings on ferro-magnetic substrates. Non-
ferrous probes measure non conductive coatings on non-ferrous metal substrates. Dual
FNF probes measure both ferrous and non-ferrous applications with automatic substrate
detection.
Range 0 - 1500µm (0 - 60mils)
Resolution 0.1µm: 0 - 100µm; 1µm: 100 - 1500µm
(0.01mil: 0 - 5mils; 0.1mil: 5 - 60mils)
Accuracy ±1-3% or ±2.5µm (±1-3% or ±0.1mil)
Probe Design
Minimum Convex
Surface Diameter
Minimum Concave
Surface Radius
Minimum
Headroom
Minimum
Sample Diameter
Straight
Ferrous 4mm (0.16") 25mm (0.98") 85mm (3.35") 4mm (0.16")
Ferrous Sealed 4mm (0.16") 25mm (0.98") 85mm (3.35") 4mm (0.16")
Non-Ferrous 10mm (0.39") 10mm (0.39") 85mm (3.35") 4mm (0.16")
Dual FNF
F Mode: 4mm (0.16")
N Mode: 26mm (1.02") 12.5mm (0.49") 88mm (3.46")
F Mode: 4mm (0.16")
N Mode: 6mm (0.24")
Right Angle
Ferrous 4mm (0.16") 25mm (0.98") 28mm (1.10") 4mm (0.16")
Non-Ferrous 10mm (0.39") 14mm (0.55") 28mm (1.10") 4mm (0.16")
Dual FNF
F Mode: 4mm (0.16")
N Mode: 26mm (1.02") 12.5mm (0.49") 38mm (1.50")
F Mode: 4mm (0.16")
N Mode: 6mm (0.24")
Anodiser Non-Ferrous 10mm (1.38") 14mm (0.55") 100mm (3.94") 4mm (0.16")
PINIP
Ferrous 4mm (0.16") 60mm (2.36") 170mm (6.69") 4mm (0.16")
Non-Ferrous 10mm (0.39") 50mm (1.97") 180mm (7.09") 4mm (0.16")
Dual FNF
F Mode: 4mm (0.16")
N Mode: 26mm (1.02") 65mm (2.56") 180mm (7.09")
F Mode: 4mm (0.16")
N Mode: 6mm (0.24")
Minimum Substrate Thickness Ferrous:
Non-Ferrous:
0.3mm (12mils)
0.1mm (4mils)
Maximum Operating
Temperature
(limited duty cycle)
Ferrous:
Non-Ferrous:
PINIP:
PINIP (High Temp):
150°C (300°F)
80°C (176°F)
80°C (176°F)
250°C (480°F)
Storage Temperature -10 to 60°C (14 to 140°F)
SCALE 1
* Whichever is the greater
en
R
www.elcometer.com 76
DFTTECH.COM
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions
Elcometer 456 Coating Thickness Gauge Grobe Range instructions

More Related Content

What's hot

Close packing and voids
Close packing and voidsClose packing and voids
Close packing and voidsMaramandansubu
 
Atomic structure presentation
Atomic structure presentationAtomic structure presentation
Atomic structure presentationNeeraj Yadav
 
Types of Electrochemical Cells
Types of Electrochemical Cells Types of Electrochemical Cells
Types of Electrochemical Cells Engr. Mukesh Kumar
 
Ele ctrode potential, electrochemical series
Ele ctrode potential, electrochemical seriesEle ctrode potential, electrochemical series
Ele ctrode potential, electrochemical seriesrajenderkarnekanti
 
Telephonic communication
Telephonic communicationTelephonic communication
Telephonic communicationPratik Madlani
 
Crystalline solids !
Crystalline solids !Crystalline solids !
Crystalline solids !Usman Shah
 
Auger Electron Spectroscopy
Auger Electron SpectroscopyAuger Electron Spectroscopy
Auger Electron Spectroscopyhasanjamal13
 
AtomicTheory 05-31-07
AtomicTheory 05-31-07AtomicTheory 05-31-07
AtomicTheory 05-31-07Gary Stilwell
 
Emission spectrum of hydrogen
Emission spectrum of hydrogenEmission spectrum of hydrogen
Emission spectrum of hydrogenRaphaelZuela
 
ELECTRO CHEMISTRY l electrolytic cell std 12 lec 1
 ELECTRO CHEMISTRY l  electrolytic cell std 12 lec 1 ELECTRO CHEMISTRY l  electrolytic cell std 12 lec 1
ELECTRO CHEMISTRY l electrolytic cell std 12 lec 1MAYURI SOMPURA
 
Spectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexesSpectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexesChris Sonntag
 
Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...
Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...
Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...Adeagbo Bamise
 

What's hot (20)

Potentiometry.pptx
Potentiometry.pptxPotentiometry.pptx
Potentiometry.pptx
 
Close packing and voids
Close packing and voidsClose packing and voids
Close packing and voids
 
Electronic spectra
Electronic spectraElectronic spectra
Electronic spectra
 
Atomic structure presentation
Atomic structure presentationAtomic structure presentation
Atomic structure presentation
 
Polarography
PolarographyPolarography
Polarography
 
Types of Electrochemical Cells
Types of Electrochemical Cells Types of Electrochemical Cells
Types of Electrochemical Cells
 
Ele ctrode potential, electrochemical series
Ele ctrode potential, electrochemical seriesEle ctrode potential, electrochemical series
Ele ctrode potential, electrochemical series
 
Telephonic communication
Telephonic communicationTelephonic communication
Telephonic communication
 
Crystalline solids !
Crystalline solids !Crystalline solids !
Crystalline solids !
 
Auger Electron Spectroscopy
Auger Electron SpectroscopyAuger Electron Spectroscopy
Auger Electron Spectroscopy
 
Voltammetry
VoltammetryVoltammetry
Voltammetry
 
AtomicTheory 05-31-07
AtomicTheory 05-31-07AtomicTheory 05-31-07
AtomicTheory 05-31-07
 
Reduced mass
Reduced massReduced mass
Reduced mass
 
Emission spectrum of hydrogen
Emission spectrum of hydrogenEmission spectrum of hydrogen
Emission spectrum of hydrogen
 
ELECTRO CHEMISTRY l electrolytic cell std 12 lec 1
 ELECTRO CHEMISTRY l  electrolytic cell std 12 lec 1 ELECTRO CHEMISTRY l  electrolytic cell std 12 lec 1
ELECTRO CHEMISTRY l electrolytic cell std 12 lec 1
 
Packing Factor
Packing Factor Packing Factor
Packing Factor
 
Spectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexesSpectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexes
 
Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...
Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...
Term Paper - Field Assisted Thermionic Emission, Field Emission, and Applicat...
 
Voltammetry
VoltammetryVoltammetry
Voltammetry
 
Elements and Atoms
Elements and AtomsElements and Atoms
Elements and Atoms
 

Viewers also liked

Horner Ohio House Testimony December 2011
Horner Ohio House Testimony December 2011Horner Ohio House Testimony December 2011
Horner Ohio House Testimony December 2011chornerlaw
 
Un plan B para la política exterior y de seguridad europea: mitigación del ca...
Un plan B para la política exterior y de seguridad europea: mitigación del ca...Un plan B para la política exterior y de seguridad europea: mitigación del ca...
Un plan B para la política exterior y de seguridad europea: mitigación del ca...Ecologistas en Accion
 
Assistive Technology: The Future
Assistive Technology: The FutureAssistive Technology: The Future
Assistive Technology: The Futureenabledbydesign
 
Edital processo seletivo 2015 the
Edital processo seletivo 2015 theEdital processo seletivo 2015 the
Edital processo seletivo 2015 theLourdes Pereira
 
Estrateia andres y oiralth
Estrateia andres y oiralthEstrateia andres y oiralth
Estrateia andres y oiralthandres castro
 
Estrategia para el Aprendizaje. Sorianny- Isleyer
Estrategia para el Aprendizaje. Sorianny- IsleyerEstrategia para el Aprendizaje. Sorianny- Isleyer
Estrategia para el Aprendizaje. Sorianny- Isleyerislehg
 
Location based mobile learning
Location based mobile learning Location based mobile learning
Location based mobile learning Kiran Budhrani
 
Rinkliavos ar kitos imokos administravimas. DVR
Rinkliavos ar kitos imokos administravimas. DVRRinkliavos ar kitos imokos administravimas. DVR
Rinkliavos ar kitos imokos administravimas. DVRLRATCA
 
Komunalinių atliekų tvarkymas Lietuvoje 2015 m
Komunalinių atliekų tvarkymas Lietuvoje 2015 mKomunalinių atliekų tvarkymas Lietuvoje 2015 m
Komunalinių atliekų tvarkymas Lietuvoje 2015 mLRATCA
 
How To Engage Audiences With Snapchat Geofilters
How To Engage Audiences With Snapchat GeofiltersHow To Engage Audiences With Snapchat Geofilters
How To Engage Audiences With Snapchat GeofiltersAustin Dixon
 

Viewers also liked (15)

Horner Ohio House Testimony December 2011
Horner Ohio House Testimony December 2011Horner Ohio House Testimony December 2011
Horner Ohio House Testimony December 2011
 
WesternVision
WesternVisionWesternVision
WesternVision
 
Un plan B para la política exterior y de seguridad europea: mitigación del ca...
Un plan B para la política exterior y de seguridad europea: mitigación del ca...Un plan B para la política exterior y de seguridad europea: mitigación del ca...
Un plan B para la política exterior y de seguridad europea: mitigación del ca...
 
Assistive Technology: The Future
Assistive Technology: The FutureAssistive Technology: The Future
Assistive Technology: The Future
 
Edital processo seletivo 2015 the
Edital processo seletivo 2015 theEdital processo seletivo 2015 the
Edital processo seletivo 2015 the
 
Liminar lula
Liminar lulaLiminar lula
Liminar lula
 
Estrateia andres y oiralth
Estrateia andres y oiralthEstrateia andres y oiralth
Estrateia andres y oiralth
 
Estrategia para el Aprendizaje. Sorianny- Isleyer
Estrategia para el Aprendizaje. Sorianny- IsleyerEstrategia para el Aprendizaje. Sorianny- Isleyer
Estrategia para el Aprendizaje. Sorianny- Isleyer
 
spring bed no 2
spring bed no 2spring bed no 2
spring bed no 2
 
Location based mobile learning
Location based mobile learning Location based mobile learning
Location based mobile learning
 
Rinkliavos ar kitos imokos administravimas. DVR
Rinkliavos ar kitos imokos administravimas. DVRRinkliavos ar kitos imokos administravimas. DVR
Rinkliavos ar kitos imokos administravimas. DVR
 
Juice
JuiceJuice
Juice
 
Komunalinių atliekų tvarkymas Lietuvoje 2015 m
Komunalinių atliekų tvarkymas Lietuvoje 2015 mKomunalinių atliekų tvarkymas Lietuvoje 2015 m
Komunalinių atliekų tvarkymas Lietuvoje 2015 m
 
Lubricacion
LubricacionLubricacion
Lubricacion
 
How To Engage Audiences With Snapchat Geofilters
How To Engage Audiences With Snapchat GeofiltersHow To Engage Audiences With Snapchat Geofilters
How To Engage Audiences With Snapchat Geofilters
 

Similar to Elcometer 456 Coating Thickness Gauge Grobe Range instructions

Datavideo TLM-702
Datavideo TLM-702Datavideo TLM-702
Datavideo TLM-702AV ProfShop
 
Datavideo TLM-702
Datavideo TLM-702Datavideo TLM-702
Datavideo TLM-702AV ProfShop
 
EDDYCON C eddy current flaw detector
EDDYCON C eddy current flaw detectorEDDYCON C eddy current flaw detector
EDDYCON C eddy current flaw detectorSvitlana Priannikova
 
Instruction manual for dhr v2.2
Instruction manual for dhr v2.2Instruction manual for dhr v2.2
Instruction manual for dhr v2.2Kaizer Bo
 
Datavideo RMC-190 PTZ camara control unit
Datavideo RMC-190 PTZ camara control unitDatavideo RMC-190 PTZ camara control unit
Datavideo RMC-190 PTZ camara control unitAV ProfShop
 
Calc fx115 ms_991ms_e
Calc fx115 ms_991ms_eCalc fx115 ms_991ms_e
Calc fx115 ms_991ms_eannnarroso
 
Instruction Manual | Guide TD210 Thermal Imaging Monocular | Optics Trade
Instruction  Manual | Guide TD210 Thermal Imaging Monocular | Optics TradeInstruction  Manual | Guide TD210 Thermal Imaging Monocular | Optics Trade
Instruction Manual | Guide TD210 Thermal Imaging Monocular | Optics TradeOptics-Trade
 
Digital Watchdog DWC-V4363DB User Manual
Digital Watchdog DWC-V4363DB User ManualDigital Watchdog DWC-V4363DB User Manual
Digital Watchdog DWC-V4363DB User ManualJMAC Supply
 
Digital Watchdog DWC-V4363TIRB User Manual
Digital Watchdog DWC-V4363TIRB User ManualDigital Watchdog DWC-V4363TIRB User Manual
Digital Watchdog DWC-V4363TIRB User ManualJMAC Supply
 
Casio fx-991EX classWiz user manual and commands.
Casio fx-991EX classWiz user manual and commands.Casio fx-991EX classWiz user manual and commands.
Casio fx-991EX classWiz user manual and commands.FarhanAhmade
 
Casio fx300 w-en
Casio fx300 w-enCasio fx300 w-en
Casio fx300 w-enDevry_2015
 
Digital Watchdog DWC-V4567WTIR User Manual
Digital Watchdog DWC-V4567WTIR User ManualDigital Watchdog DWC-V4567WTIR User Manual
Digital Watchdog DWC-V4567WTIR User ManualJMAC Supply
 
Digital Watchdog DWC-V4567WD User Manual
Digital Watchdog DWC-V4567WD User ManualDigital Watchdog DWC-V4567WD User Manual
Digital Watchdog DWC-V4567WD User ManualJMAC Supply
 
Megger-BM802-User-Manual.pdf
Megger-BM802-User-Manual.pdfMegger-BM802-User-Manual.pdf
Megger-BM802-User-Manual.pdfjiboory1
 
Datavideo TLM-433
Datavideo TLM-433Datavideo TLM-433
Datavideo TLM-433AV ProfShop
 
Datavideo TLM-433
Datavideo TLM-433Datavideo TLM-433
Datavideo TLM-433AV ProfShop
 
Ultimaker original assembly_manual_v1.1
Ultimaker original assembly_manual_v1.1Ultimaker original assembly_manual_v1.1
Ultimaker original assembly_manual_v1.1Franck Lecluse
 

Similar to Elcometer 456 Coating Thickness Gauge Grobe Range instructions (20)

Datavideo TLM-702
Datavideo TLM-702Datavideo TLM-702
Datavideo TLM-702
 
Datavideo TLM-702
Datavideo TLM-702Datavideo TLM-702
Datavideo TLM-702
 
EDDYCON C eddy current flaw detector
EDDYCON C eddy current flaw detectorEDDYCON C eddy current flaw detector
EDDYCON C eddy current flaw detector
 
Instruction manual for dhr v2.2
Instruction manual for dhr v2.2Instruction manual for dhr v2.2
Instruction manual for dhr v2.2
 
Datavideo RMC-190 PTZ camara control unit
Datavideo RMC-190 PTZ camara control unitDatavideo RMC-190 PTZ camara control unit
Datavideo RMC-190 PTZ camara control unit
 
Calc fx115 ms_991ms_e
Calc fx115 ms_991ms_eCalc fx115 ms_991ms_e
Calc fx115 ms_991ms_e
 
Fx570 ms manual
Fx570 ms manualFx570 ms manual
Fx570 ms manual
 
Instruction Manual | Guide TD210 Thermal Imaging Monocular | Optics Trade
Instruction  Manual | Guide TD210 Thermal Imaging Monocular | Optics TradeInstruction  Manual | Guide TD210 Thermal Imaging Monocular | Optics Trade
Instruction Manual | Guide TD210 Thermal Imaging Monocular | Optics Trade
 
Digital Watchdog DWC-V4363DB User Manual
Digital Watchdog DWC-V4363DB User ManualDigital Watchdog DWC-V4363DB User Manual
Digital Watchdog DWC-V4363DB User Manual
 
Digital Watchdog DWC-V4363TIRB User Manual
Digital Watchdog DWC-V4363TIRB User ManualDigital Watchdog DWC-V4363TIRB User Manual
Digital Watchdog DWC-V4363TIRB User Manual
 
How tu use an oscilloscope
How tu use an oscilloscopeHow tu use an oscilloscope
How tu use an oscilloscope
 
Casio fx-991EX classWiz user manual and commands.
Casio fx-991EX classWiz user manual and commands.Casio fx-991EX classWiz user manual and commands.
Casio fx-991EX classWiz user manual and commands.
 
Casio fx300 w-en
Casio fx300 w-enCasio fx300 w-en
Casio fx300 w-en
 
Digital Watchdog DWC-V4567WTIR User Manual
Digital Watchdog DWC-V4567WTIR User ManualDigital Watchdog DWC-V4567WTIR User Manual
Digital Watchdog DWC-V4567WTIR User Manual
 
Digital Watchdog DWC-V4567WD User Manual
Digital Watchdog DWC-V4567WD User ManualDigital Watchdog DWC-V4567WD User Manual
Digital Watchdog DWC-V4567WD User Manual
 
Megger-BM802-User-Manual.pdf
Megger-BM802-User-Manual.pdfMegger-BM802-User-Manual.pdf
Megger-BM802-User-Manual.pdf
 
Fx 570 991-es_plus_en
Fx 570 991-es_plus_enFx 570 991-es_plus_en
Fx 570 991-es_plus_en
 
Datavideo TLM-433
Datavideo TLM-433Datavideo TLM-433
Datavideo TLM-433
 
Datavideo TLM-433
Datavideo TLM-433Datavideo TLM-433
Datavideo TLM-433
 
Ultimaker original assembly_manual_v1.1
Ultimaker original assembly_manual_v1.1Ultimaker original assembly_manual_v1.1
Ultimaker original assembly_manual_v1.1
 

More from DFT TECH

Elcometer 456 IPC industrial protective coating thickness gauge instructions
Elcometer 456 IPC industrial protective coating thickness gauge instructionsElcometer 456 IPC industrial protective coating thickness gauge instructions
Elcometer 456 IPC industrial protective coating thickness gauge instructionsDFT TECH
 
Elcometer 456 Coating Thickness Gauge instructions Manual in Engilish
Elcometer 456 Coating Thickness Gauge instructions Manual in EngilishElcometer 456 Coating Thickness Gauge instructions Manual in Engilish
Elcometer 456 Coating Thickness Gauge instructions Manual in EngilishDFT TECH
 
Elcometer 415 c industrial Paint Powder Thickness Gauge Iinstructions
Elcometer 415 c industrial Paint Powder Thickness Gauge IinstructionsElcometer 415 c industrial Paint Powder Thickness Gauge Iinstructions
Elcometer 415 c industrial Paint Powder Thickness Gauge IinstructionsDFT TECH
 
Elcometer 355 Coating Thickness Gauge Standard Model instructions
Elcometer 355 Coating Thickness Gauge Standard Model instructionsElcometer 355 Coating Thickness Gauge Standard Model instructions
Elcometer 355 Coating Thickness Gauge Standard Model instructionsDFT TECH
 
Elcometer 311C Automotive Paint Meter Operating instructions / Working Manual
Elcometer 311C Automotive Paint Meter Operating instructions / Working ManualElcometer 311C Automotive Paint Meter Operating instructions / Working Manual
Elcometer 311C Automotive Paint Meter Operating instructions / Working ManualDFT TECH
 
Brookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBT
Brookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBTBrookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBT
Brookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBTDFT TECH
 

More from DFT TECH (6)

Elcometer 456 IPC industrial protective coating thickness gauge instructions
Elcometer 456 IPC industrial protective coating thickness gauge instructionsElcometer 456 IPC industrial protective coating thickness gauge instructions
Elcometer 456 IPC industrial protective coating thickness gauge instructions
 
Elcometer 456 Coating Thickness Gauge instructions Manual in Engilish
Elcometer 456 Coating Thickness Gauge instructions Manual in EngilishElcometer 456 Coating Thickness Gauge instructions Manual in Engilish
Elcometer 456 Coating Thickness Gauge instructions Manual in Engilish
 
Elcometer 415 c industrial Paint Powder Thickness Gauge Iinstructions
Elcometer 415 c industrial Paint Powder Thickness Gauge IinstructionsElcometer 415 c industrial Paint Powder Thickness Gauge Iinstructions
Elcometer 415 c industrial Paint Powder Thickness Gauge Iinstructions
 
Elcometer 355 Coating Thickness Gauge Standard Model instructions
Elcometer 355 Coating Thickness Gauge Standard Model instructionsElcometer 355 Coating Thickness Gauge Standard Model instructions
Elcometer 355 Coating Thickness Gauge Standard Model instructions
 
Elcometer 311C Automotive Paint Meter Operating instructions / Working Manual
Elcometer 311C Automotive Paint Meter Operating instructions / Working ManualElcometer 311C Automotive Paint Meter Operating instructions / Working Manual
Elcometer 311C Automotive Paint Meter Operating instructions / Working Manual
 
Brookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBT
Brookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBTBrookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBT
Brookfield Dial Viscometer Technical Brochures for Models LVT, RVT, HAT, HBT
 

Recently uploaded

Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxOnBoard
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Enterprise Knowledge
 
"Federated learning: out of reach no matter how close",Oleksandr Lapshyn
"Federated learning: out of reach no matter how close",Oleksandr Lapshyn"Federated learning: out of reach no matter how close",Oleksandr Lapshyn
"Federated learning: out of reach no matter how close",Oleksandr LapshynFwdays
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesSinan KOZAK
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Alan Dix
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphNeo4j
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhisoniya singh
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...Fwdays
 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024BookNet Canada
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupFlorian Wilhelm
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDGMarianaLemus7
 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraDeakin University
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 

Recently uploaded (20)

Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptx
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024
 
"Federated learning: out of reach no matter how close",Oleksandr Lapshyn
"Federated learning: out of reach no matter how close",Oleksandr Lapshyn"Federated learning: out of reach no matter how close",Oleksandr Lapshyn
"Federated learning: out of reach no matter how close",Oleksandr Lapshyn
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen Frames
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
 
DMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special EditionDMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special Edition
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project Setup
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDG
 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning era
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 

Elcometer 456 Coating Thickness Gauge Grobe Range instructions

  • 1. Operating Instructions The New Elcometer 456 Coating Thickness Gauge DFTTECH.COM
  • 2. Gauge Dimensions: 141 x 73 x 37mm (5.55 x 2.87 x 1.46"). Gauge Weight: Integral: 156g (5.5oz) including batteries; Separate: 161g (5.68oz) including batteries. Applicable patents: US6243 661; US5886522; US6762603; US7606671; GB2306009; GB2367135; GB2342450, DE10131827 © Elcometer Limited 2012 - 2015.All rights reserved. No part of this document may be reproduced, transmitted, transcribed, stored (in a retrieval system or otherwise) or translated into any language, in any form or by any means (electronic, mechanical, magnetic, optical, manual or otherwise) without the prior written permission of Elcometer Limited. www.elcometer.comTMA-0489 Issue 10 R en Pb Hg DFTTECH.COM
  • 3. Section Page 1 GAUGE OVERVIEW AND BOX CONTENTS........................................................... 4 2 GETTING STARTED................................................................................................. 5 3 TAKING A READING................................................................................................. 7 4 CALIBRATING THE GAUGE.................................................................................... 8 5 THE DISPLAY........................................................................................................... 9 6 THE GAUGE FEATURES......................................................................................... 12 7 MEASUREMENT MODES (ST)................................................................................ 25 8 BATCHING (ST)........................................................................................................ 26 9 DOWNLOADING DATA USING ELCOMASTER (BST)............................................ 35 10 ELCOMASTER MOBILE APPS (ST)........................................................................ 55 11 CLOUD COMPUTING USING ELCOMASTER (ST)................................................ 56 12 GETTING THE MOST OUT OF ELCOMASTER...................................................... 58 13 CALIBRATING THE ELCOMETER 456 (EBST)....................................................... 60 14 CHANGING THE WELCOME SCREEN (BST)......................................................... 64 15 GAUGE FIRMWARE UPDATES (BST).................................................................... 65 16 GAUGE ICONS & ERROR CODES (EBST)............................................................. 66 17 GAUGE MENU STRUCTURES (EBST)................................................................... 70 18 ABOUT IMO PSPC (ST)........................................................................................... 74 19 GAUGE TECHNICAL SPECIFICATIONS (EBST).................................................... 75 20 PROBE TECHNICAL SPECIFICATIONS (EBST)..................................................... 76 21 GAUGE & PROBE ACCESSORIES (EBST)............................................................ 80 22 ADDITIONAL REFERENCE INFORMATION........................................................... 82 23 LEGAL NOTICES & REGULATORY INFORMATION.............................................. 83 24 INDEX....................................................................................................................... 85 www.elcometer.com R en CONTENTS DFTTECH.COM
  • 4. R en www.elcometer.com WELCOME Thank you for your purchase of this Elcometer 456 Coating Thickness Gauge. Welcome to Elcometer. Elcometer are world leaders in the design, manufacture and supply of coatings inspection equipment. Our products cover all aspects of coating inspection, from development through application to post application inspection. The Elcometer 456 Coating Thickness Gauge is a world beating product. With the purchase of this gauge you now have access to the worldwide service and support network of Elcometer. For more information visit www.elcometer.com ABOUTYOUR GAUGE The Elcometer 456 Coating Thickness Gauge is a handheld gauge for fast and accurate measurement of the thickness of coatings on metal substrates. The gauge is available in four models; Model E, B, S andT. This manual describes the operation of all the Elcometer 456 models and indicates, where necessary, which specific model(s) the feature is available on in brackets after the feature. All versions of the gauge feature an easy-to-use menu driven graphical interface which guides the user through tasks such as gauge configuration and calibration adjustment. The gauge is available either with a built-in integral probe or as a separate probe version. A wide range of probes is available to suit requirements. CONVENTIONS IN THESE INSTRUCTIONS The Elcometer 456 is operated using a simple menu structure which helps you get the most from your gauge. As an example, the Languages option is located within Setup which is under the Menu softkey and is shown in these instructions as: Menu/Setup/Language 3 DFTTECH.COM
  • 5. Packaging The gauge is packed in cardboard packaging. Please ensure that this packaging is disposed of in an environmentally sensitive manner. Please Consult your Local Environmental Authority for further guidance. 1 GAUGE OVERVIEWAND BOX CONTENTS www.elcometer.com 4 R en Gauge Overview 1 LED Indicators - Red (left), Green (right) 2 Colour Screen 3 Multifunction Softkeys 4 On/Off Key 5 Internal Probe / Separate Probe Connection 6 USB Data Output Socket (below cover) 7 Battery Compartment (¼ turn open/close) 8 Wrist Strap Connection Box Contents § Elcometer 456 CoatingThickness Gauge § Calibration Foils (Integral gauges) § Test Certificate § Wrist Harness § Protective Case (B, S &Tmodels) § Transit Case (Tmodel) § 1 x Screen Protector (S &Tmodels) § 2 xAABatteries § USB Cable & ElcoMaster™ Software (S & T models) § User Guide 1 2 3 4 5 6 8 7 DFTTECH.COM
  • 6. en R www.elcometer.com5 2 GETTING STARTED Fitting the batteries Your gauge is supplied with batteries ready to fit. To insert or replace the batteries: 1. Lift the latch at the back of the gauge and + rotate anticlockwise. 2. Remove the battery compartment cover. 3. Insert 2 batteries (type LR6/AA) taking care to ensure correct battery polarity. 4. Replace battery compartment cover and rotate the latch clockwise to close. The battery condition is indicated by a symbol in the top right of the display: • Full symbol (orange) = batteries at full capacity • Empty symbol (red, flashing) = batteries at lowest sustainable level To maximise battery life, ensure that Auto Screen Brightness is selected, or the screen brightness is low via Menu/Setup/Screen Settings/Screen Brightness and the Bluetooth is disabled (if you are not using it) via Menu/Bluetooth and uncheck the Enable Bluetooth radio button. Connecting the probe (separate gauges only) 1. Rotate the probe plug to align the pins 2. Screw in the collar - clockwise 1 21 2 + + DFTTECH.COM
  • 7. www.elcometer.com 6 R en Fitting the wrist harness Awrist harness is supplied with each gauge. This can be fitted into the right hand side of the gauge using the wrist strap connection. To fit the harness, pass the harness loop through the wrist strap connection, pass the main wrist harness through the loop and pull. Switching the gauge on/off Ÿ To switch on, press on/off key for more than 0.5 seconds. Ÿ To switch off, press and hold on/off key until the screen blanks. The gauge will switch off automatically after 5 minutes of inactivity. To switch off this feature, press Menu/Setup and uncheck the Gauge Auto Off radio button. Selecting a language When the gauge is switched on for the first time after dispatch from the Elcometer factory the display will show the language selection screen: 1. Select your language using the éê softkeys 2. Follow the on screen menus To access the language menu when in a foreign language: 1. Switch the gauge OFF 2. Press and hold the left softkey and switch the gauge ON é3. Select your language using the softkeysê The language can also be changed via Menu/Setup/Language Selecting units The Elcometer 456 can display readings in both metric and imperial measurement units (microns, millimetres, mils or inches). The appropriate measurement unit can be changed via Menu/Setup/Units Adjusting the beep volume Each time a measurement is taken, the gauge will beep. The beep volume can be adjusted and can even be switched off via Menu/Setup/Beep Volume DFTTECH.COM
  • 8. www.elcometer.com7 en R 3 TAKING A READING 1. Hold the gauge (integral) or the probe by its sleeve (separate gauge) 2. To take a reading, bring the probe down onto the surface whilst holding it perpendicular 3. For subsequent readings, lift the probe off and then replace it onto the coated surface ü DO • Hold the probe by the probe sleeve • Gently place the probe onto the surface • Allow the sleeve to make contact with the surface - to improve accuracy û DO NOT • Drag the probe over the coated surface • Bang the probe down hard onto the surface • Allow the probe to hover over the surface as this could result in a false reading DFTTECH.COM
  • 9. www.elcometer.com 8 R en 90° 4 CALIBRATING THE GAUGE Calibration adjustment is the process of setting the gauge to known values of thickness to ensure accuracy on different substrate types, shapes and surface finishes. The calibration of the gauge can be adjusted using several different methods for use in accordance with National and International Standards and the calibration adjustment method chosen depends on the condition of the substrate to be measured. 1. Press the Cal softkey 2. For alternative calibration methods, select Cal/Cal Method 3. Select Calibrate and follow the on-screen instructions 4. When prompted place the probe on the centre of the foil(s) or on the uncoated metal substrate Foils can also be stacked to increase the thickness value. The calibration method is indicated on the screen by a symbol - see Multiple Calibration Methods on page 18. Not all calibration methods are available for all gauge types. For a comprehensive guide to each calibration method and the calibration adjustment process see Multiple Calibration Methods on page 18. When using an FNF probe it must be calibrated in both the ferrous mode and in the non-ferrous mode to ensure accuracy of reading. When using an Ultra/Scan probe in Scan Mode or Auto Repeat Mode (see Measurement Modes on page 25), it must be calibrated using either the Smooth or Rough/2 Point calibration method - see Multiple Calibration Methods on page 18. For more information on calibrating the Elcometer 456, see page 60. DFTTECH.COM
  • 10. 5 THE DISPLAY The Elcometer 456 gauge has a colour display: • White characters: All measurement and statistical values. • Orange characters: All menu items, statistical parameters and symbols. • Red: A measurement value which is outside set limits; a limit symbol when the limit value has been exceeded (Model S & T). • - - - indicates reading outside range of probe. If you see the Cal softkey flashing, the gauge should be calibrated. www.elcometer.com9 en R j b a c f m l n o p q I h k s u r t w v d e g DFTTECH.COM
  • 11. Model a Green LED EBST b Battery Life Indicator EBST c Bluetooth On ST d Substrate Type - F, N, FNF EBST e Calibration Method BST f Reading Outside Calibration Warning On T g Upper Limit On ST h Units of Measurement - µm, mils, mm, inch EBST i Batch Type - normal, counted average, IMO ST j Menu Softkey EBST k Display Softkey BST l Red LED - Reading outside limit/ IMO Fail ST m Batch Name (when in batching) T Date & Time (when not in batching) ST n User Selectable Statistics - 4 rows BST o Reading Value EBST p Calibration Softkey EBST q Batch / Data Softkey BST r Bar Graph - highest, lowest & average reading BST s Lower Limit On ST t Measurement Mode - Standard, Auto Repeat, Scan T u Softkeys EBST v Run Chart - last 20 readings ST w Upper & Lower Limits On ST For a complete list of icons, see “Gauge Icons” on page 66 - 68 www.elcometer.com 10 R en DFTTECH.COM
  • 12. Reading display size (BST) The character size of the measurement value on the display increases or decreases depending on the number of statistics that are displayed; or if a graph is displayed on the measurement screen . To maximise the reading size, either: Ÿ reduce the number of statistical values that are displayed via Display/Statistics/Select Statistics, or Ÿ display the reading only by checking the Display/Readings Only radio button. www.elcometer.com11 en R DFTTECH.COM
  • 13. 6 THE GAUGE FEATURES The Elcometer 456 coating thickness gauge has a number of easy to use features and functions to help the user be more efficient.These include: Fast reading rate (EBST) The Elcometer 456 is capable of taking greater than 70 accurate, repeatable and reproducible measurements every minute. Easy to use menu structure in more than 30 languages (EBST) Designed to be intuitive, the Elcometer 456 menus and calibration instructions are available in multiple languages via Menu/Setup/Language. Bright colour screen (EBST) Each gauge is supplied with a scratch and solvent resistant 2.4" (60mm) TFT colour screen which clearly displays the reading. The screen brightness can be adjusted manually (EBST) - via Menu/Setup/Screen Settings/Screen Brightness/Manual or automatically (BST) using the gauge’s ambient light sensor which can be switched on via Menu/Setup/Screen Settings/Screen Brightness/Auto. Battery or USB Powered (EBST) Each gauge can be powered either using 2 x AA lithium, alkaline or rechargeable batteries or by connecting the Elcometer 456 to your PC via a USB cable. Two year gauge warranty (EBST) The Elcometer 456 gauge is supplied with a 1 year warranty against manufacturing defects. To extend this warranty to 2 years, simply register your gauge via the elcometer.com website. Emergency light mode (BST) If all the lighting fails during an inspection in dark environments, the gauge is fitted with an emergency light feature - once selected (Menu/EmergencyLight),thedisplayturnsbrightwhite.Toswitchoffthis functioneitherpressandholdtheEscsoftkeyorpoweroffthegauge. R en www.elcometer.com 12 DFTTECH.COM
  • 14. Automatic rotating display (BST) Using the internal accelerometer, the gauge will automatically rotate the display to allow you to easily read the thickness value in any orientation - 0°, 90°, 180° & 270°. This function can be switched off by un-checking Menu/Setup/Screen Settings/Auto Display Rotation Gauge firmware updates (BST) Using Elcometer’s free data management software, ElcoMaster™, users can receive prompts when there is a gauge firmware update available for their model version. When the Elcometer 456 is connected (via USB), to any computer with an internet connection and with ElcoMaster™ installed, ElcoMaster™ highlights the availability of a firmware update, identifies to the user the new features and guides the user through the gauge firmware update process. Caution, before upgrading your gauge firmware, ensure that you have downloaded all inspection readings from the gauge. For more information regarding ElcoMaster™ see page 35 Downloading Data. Bluetooth™ (ST) and USB Data output (BST) Elcometer 456 gauges have the ability to transfer data via USB (BST) to a computer or wirelessly via Bluetooth™ (ST) technology to PC’s, PDA’s or mobile phones which are Bluetooth™ enabled using ElcoMaster™ or ElcoMaster™ MobileApps respectively. B l u e t o o t h ™ d a t a o u t p u t c a n b e s w i t c h e d o n v i a Menu/Bluetooth/Enable Bluetooth. For more information regarding ElcoMaster™ see page 35 Downloading Data. ElcoMaster™ Data output (BST) Users can download data from any Elcometer gauge directly into ElcoMaster™ by connecting the gauge to the PC and following the on screen prompts. www.elcometer.com13 en R DFTTECH.COM
  • 15. Symbol / icon Model Description η BST The number of readings taken x BST Mean (average) σ BST Standard deviation Hi BST Highest reading taken Lo BST Lowest reading taken cv% BST Coefficient of variation; The COV is defined as the ratio of the standard deviation to the mean and is a normalised measure of dispersion - when comparing batches with widely different means, one should use the coefficient of variationforcomparisoninsteadofstandarddeviation(σ). Once the data has been transferred to the computer, the user can produce professional reports in seconds. Data can also be transferred ® into programs, such as Excel , in a similar manner. For more information regarding ElcoMaster™ see page 35 Downloading Data. Counted Average (BST) Users can define the number of individual gauge readings to be taken within a spot or measurement area using the Counted Average function. The gauge stores the average of the individual readings into memory. The individual readings within the counted average are not saved. Select Display/Statistics/CountedAverage. Counted Average is also available when in Batching (ST) - see BatchTypes on page 32. On Screen Statistics (BST) User selectable statistical and general measurement information can be displayed on the gauge. The information to be displayed can be selected and managed by selecting the Display softkey. Ÿ Up to 8 statistics can be selected to be displayed on the reading screen via Display/Statistics/Select Statistics Ÿ Ensure that Display/Readings & Selected Stats is also checked. Ÿ To view all statistics select Display/Statistics/ViewAll The following statistical and general information can be displayed on your gauge: R en www.elcometer.com 14 DFTTECH.COM
  • 16. Symbol / icon Model Description EIV BST Elcometer index value; Used to assess a coating’s overall quality. Ideal for use in the automotive refinishing industry.USApatentnumberUS7606671. NDFT ST Nominal dry film thickness; The target or specified dry film coating thickness value. IMO PSPC ST International Maritime Organisation’s Performance Standard for Protective Coatings clearly defines the acceptance criteria for a coating. The Elcometer 456 can be quickly set up to display these parameters: % > N ST The percentage of readings greater than or equal to the Nominal Dry FilmThickness Value. 90 % 100 ST The percentage of readings between 0.9 x NDFT and the NDFT. 90:10 ST Displays either pass (ü) or fail (X) To pass the IMO PSPC 90/10 rule: Ÿ At least 90% of all dry film thickness readings shall be greater than or equal to the NDFTvalue, and Ÿ none of the remaining measurements shall be below 0.9 x NDFT X! ST If all the measurements taken at any point are greater than 0.9 x NDFT, but less than 90% of the readings are greater than or equal to the NDFT, were the inspection to stop, then the IMO PSPC condition would be a fail. Statistically, however, were more measurements to be taken which were all greater than or equal to the NDFT, then there would come a time when the IMO PSPC condition returns to a pass. This is depicted by the “failing” icon - X!. For more information on the IMO PSPC seeAbout IMO PSPC on page 74. ST Low Limit ST High Limit ST Number of readings below the low limit ST Number of readings above the high limit User definable warning limits can be set. Once the reading exceeds the limit the gauge notifies the user by turning the reading and relevant limit icon red, flashing the red LED, and sounding the alarm beep. For more information see Limits on page 23. www.elcometer.com15 en R n n DFTTECH.COM
  • 17. Analogue Bar Graph (BST) ByselectingDisplay/Readings&BarGraph theusercanviewananaloguerepresentation of the current thickness value together with the highest (Hi), lowest (Lo) and average (x) reading. The graph is updated automatically wheneachreadingistaken. The values on the top left and right of the bar signify the measurement range using the thin calibration foil value less 10% and the thick calibration foil value plus 10%. If calibrated using the factory calibration, the probe scale range ±10% is used. If limits are set, the limit values ±10% are used and the relevant limit icon is displayed above the bar intheappropriateposition. With Limits: The current measurement is displayed as a white or red bar; white if within set limits, and red if outside set limits. If below the lower limit, the left arrow head is also filled red and if above the upper limit, the right arrow head is filled red. If the next measurement taken is within set limits, the left or right arrow outline will remain red to signify that the previous reading was outside set limits. WithoutLimits:Thecurrentmeasurementisdisplayedasawhitebar. If outside the measurement range, the left or white arrow head is also filled white. If the next measurement taken is within range, the left or right arrow outline will remain white to signify that the previous reading was outside range. 4 Users can choose to show Readings & Selected Stats (ST) - see On Screen Statistics on page 14, Readings & Run Chart (ST) - see Run Chart on page 17, Readings & Bar Graph (BST) or Readings Only (BST). Readings & Run Chart is only available when in Batching, it is not available in Standard (Immediate) Mode. R en www.elcometer.com 16 DFTTECH.COM
  • 18. Run Chart (ST) By selecting Display/Readings & Run Chart the user can view a line trend graph of the last 20 measurements. The graph is updated automatically when each reading is taken. Up to five horizontal axes are displayed representing different values / statistics as follows: Ÿ Highest reading in the batch “ ” Ÿ Lowest reading in the batch “ ” (for batches of more than one reading) Ÿ Mean of readings in the batch “ ” (for batches of more than one reading) Ÿ High limit for the batch “ ” (when enabled) Ÿ Low limit for the batch “ ” (when enabled) The readings are displayed as white or red points; white if a reading is within limits (or no limits have been set), and red if outside set limits. When in Scan Mode (T) - see Measurement Modes on page 25, the Analogue Bar Graph is displayed on screen whilst scanning. This is replaced by the Run Chart when the scan is completed. The highest and lowest reading for each scan is displayed on the run chart above and below the average value together with either a white or red vertical line; white if within set limits, and red if outside set limits. The highest, average and lowest reading values for the last scan are also displayed under the run chart. 4 Users can choose to show Readings & Selected Stats (ST) - see On Screen Statistics on page 14, Readings & Run Chart (ST), Readings & Bar Graph (BST) - see Analogue Bar Graph on page 16 or Readings Only (BST). Readings & Run Chart is only available when in Batching, it is not available in Standard (Immediate) Mode. Time and date (ST) Oncetheappropriatetimeanddatehasbeenset(Menu/Setup/Timeand Date), the user can display the time and date at the top of the Elcometer 456displayviaMenu/Setup/TimeandDate/DisplayTimeandDate. www.elcometer.com17 en R DFTTECH.COM
  • 19. Ÿ The time format can be set to either the 12 hour or 24 hour clock via Menu/Setup/Time and Date/Set Format/Set Time Format Ÿ The date format can be set to either dd/mm/yyyy, mm/dd/yyyy or yyyy/mm/dd via Menu/Setup/Time and Date/Set Format/Set Date Format Please note that the time and date is replaced by the batch name when the gauge is in Batch mode. When a batch is created, re-opened (or when the gauge is switched on whilst in batch mode) and when each reading is taken, the time and date details are stored within the batch - allowing the user to have an accurate record of when the measurements were taken. The time and date stamp for each reading is displayed on ElcoMaster™. Multiple calibration methods (EBST) Calibration adjustment is the process of setting the gauge to known values of thickness to ensure accuracy on different substrate types, shapes and surface finishes and is often referred to as simply the “calibration”. The calibration of the gauge can be adjusted using several different methods for use in accordance with National and International Standards and the calibration adjustment method chosen depends on the condition of the substrate to be measured. The calibration method is indicated on the screen by a symbol. When using an FNF probe it must be calibrated in both the ferrous mode and in the non-ferrous mode to ensure accuracy of reading. When using an Ultra/Scan probe in Scan Mode or Auto Repeat Mode (see Measurement Modes on page 25), it must be calibrated using either the Smooth or Rough/2 Point calibration method. When switching between the Scale 1 and Scale 2 functions of the scale 2 probes (Menu/Setup/Probe) the Elcometer 456 should be re- calibrated to ensure accuracy across the appropriate measurement range. www.elcometer.com 18 R en DFTTECH.COM
  • 20. Method Description Icon Model Zero A simple method for calibrating on smooth substrates. Simply place the probe on the uncoated metal and the gauge will adjust the calibration accordingly. Also known as the single point calibration method. BST Smooth This is a more accurate method of calibrating the gauge than the Zero method as it requires the user to calibrate the gauge using a foil and the un-coated substrate. The gauge’s on-screen calibration instructions will guide the user through the calibration routine. When selecting the foil value, the user should choose a thickness that is close to but greater than the expected dry film thickness value. BST Rough / 2 Point Ideal for calibrating the gauge on both profiled metal substrates (when the uncoated surface is accessable) and substrates where there are significant differences in the magnetic (F) or electrical (N) properties of the substrate. For example cast iron, high carbon steel or some non-magnetic stainless steel alloys. The calibration requires 2 foil values - one above the expected dry film thickness, and one below. The gauge will guide the user through the process with on screen instructions. EBST Zero Offset This is the ISO 19840 method for coatings on steel surfaces roughened by blast cleaning or when the substrate profile is unknown, or not accessible. The calibration uses the smooth surface technique, and a correction value (zero offset) is applied to each reading to account for the effect of the roughened surface; the value of the offset depends on the initial surface profile and is described in ISO 19840 as follows: ST Profile according to ISO 8503-1 Correction Offset *Value µm (mils ) Fine 10 (0.4) Medium 25 (1.0) Coarse 40 (1.6) * mils values are calculated and for reference as ISO 19840 indicates metric units only www.elcometer.com19 en R DFTTECH.COM
  • 21. Method Description Icon Model Auto This is a calibration method unique to the Elcometer 456 and has been designed to simplify and speed up the calibration process for those users who are calibrating their gauge using the same foil values each time. When the Auto calibration method is selected, the user is asked to pre-program the high and low foil values. The low foil value can be set to 0.0µm (0.0mils) for un-coated substrates. Once these foil values have been set up, selecting the calibrate routine allows the user to simply place the probe on the high foil three times, followed by the low foil three times and the gauge is automatically calibrated - returning the user to the main reading screen - automatically. ST Factory By selecting this calibration method the Elcometer 456 returns the calibration to the gauge’s factory calibration settings. The factory calibration method should only be used if there is no other means of calibration (e.g. lost foils, lack of access to substrate, etc.). EBST Pre-defined Calibration Methods (ST) In addition to the standard calibration methods described on pages 16 - 18, the Elcometer 456 has a four pre-defined calibration methods which follow relevant standards. These pre-defined calibration methods not only define the calibration routine to be used, but also set up the data collection method, as defined by the appropriate standard. For this reason, pre-defined calibration methods can only be selected whilst the gauge is in batching mode. For more information on batching or data collection methods, see Batching on page 26. www.elcometer.com 20 R en DFTTECH.COM
  • 22. Method Description Icon Model ISO Sets the calibration method to Zero Offset and sets the Counted Average to 5 - in accordance with ISO19840. ST SSPC PA2 Sets the calibration method to Rough/2 Point and sets the Counted Average to 3 - in accordance with SSPC PA2. ST Swedish Sets the calibration method to Rough/2 Point and sets the Counted Average to 5 - in accordance with Swedish standards. ST Australian Sets the calibration method to Zero Offset, and sets the Counted Average to 5 - in accordance with AS standards. ST For more information on how to calibrate the gauge, see Calibrating the Elcometer 456 on page 60. User-programmable calibration memories (T) The Elcometer 456 Model T allows users to store into memory up to three calibrations. Once a calibration memory has been saved, the user can select the calibration memory - without the need to re-calibrate the gauge. Calibration memories are ideal for users who are inspecting coatings on various curvatures, blast profiles or coating thicknesses. Using the gauge’s alpha-numeric function, users can re-name the calibration memory to suit the calibration setting. For example: Ÿ A user who is inspecting coatings on two blast profiles - shot and grit could store calibrations into Cal Memory 1 and Cal Memory 2 and re-name them ‘Shot’and ‘Grit’respectively Ÿ A user measuring on flat and curved surfaces could store the calibrations into ‘Flat cal’and ‘Curved cal’. Ÿ Thick and thin coating thickness calibrations can also be saved and renamed ‘320µm’and ‘120µm’ For more information on re-naming calibration memories, see Alpha- numeric naming of batches and cal memories on page 27. www.elcometer.com21 en R DFTTECH.COM
  • 23. Outside calibration warning (T) In order to achieve the most accurate reading the gauge should be calibrated to the substrate type, shape and profile using the appropriate calibration method together with foil values that are slightly above the target dry film thickness. When using the gauge’s calibration memories, or batching (see Batching on page 26) different calibration foil values may be used in each calibration. value if using Rough/ 2 point) the gauge reading alarm sounds a triple beep and the Calibration Check icon (located above the units symbol) turns red. This feature does not amend or tag any reading, it is a real time warning feature only. Calibration lock (BST) To avoid accidental amendments to the calibration settings switching on the Cal/Calibration Lock feature’ locks’ the user from undertaking any changes to the calibration without first un-checking the Cal/Calibration Lock feature. When the Calibration Lock is enabled, users can still test the calibration via Cal/Test Calibration but will be unable to validate or re-calibrate the gauge. The calibration can also be locked using a PIN Code, see page 63 for more information. Once the Outside calibration warning function Cal/Calibration Check has been switched on, if a coating thickness reading is taken which is more than 10% above the foil value (and 10% below the lower foil www.elcometer.com 22 R en DFTTECH.COM
  • 24. Gauge Memory (BST) The Elcometer 456 versions are supplied with a varying level of memory: Model E: No memory Model B: The Model B gauge’s ‘rolling statistics’ provides accurate statistical values for all measurements taken since the statistics were last cleared (Display/Clear Statistics). The last 5 readings, however, can be displayed by pressing the Data softkey. Model S: 1,500readingscanbestoredintothegauge’smemory Model T: A total of 150,000 readings can be stored into the gauge’s memory either in a single batch or in up to 2,500 batches (see Batching on page 26). Each batch can be individually named and can have its own unique calibration. Limits (ST) During the inspection process coatings can often have specified minimum and/or maximum thickness values. For example, coatings that have been applied too thinly over a surface profile can lead to rust spots appearing on the peaks of the profile. Similarly too thick a coating can also lead to premature coating failures. Users can program upper and/or lower warning limits into the Elcometer 456 gauge by selecting Menu/Set Limits/Set Upper or Menu/Set Limits/Set Lower. To switch the limits on, the user should ensure that the Enable Limits radio button is checked. Ÿ When an Upper Limit has been set up and enabled the “ ” icon is displayed. Ÿ When a Lower Limit has been set up and enabled the “ ” icon is displayed. Ÿ If both Upper and Lower limits have been set up and enabled then the two icons are displayed together as “ ”. www.elcometer.com23 en R DFTTECH.COM
  • 25. When the Elcometer 456 gauge takes a reading which is outside the set limits the following occurs: Ÿ The Red LED flashes Ÿ The reading is displayed in red Ÿ The alarm beeps 3 times Ÿ The associated limit icon turns red In addition, the number of readings above limit (or below limit as applicable) statistic is incremented. In Batching, the reading is tagged with either the high or low icon as appropriate. For more information see Batching on page 26. To switch off a particular limit go to Menu/Set Limits/Set Upper or Menu/Set Limits/Set Lower and set the limit value to Off using the up and down soft keys. The programmed limit values can be displayed on the reading screen via Display/Statsitics/Select Statistics and checking the appropriate radio button. The maximum number of statistics that can be displayed on the reading screen at the same time is 8. If a low limit has been set up, the upper limit value cannot be lower than the pre-set lower limit. Individual limits can also be set up for each batch on Model T gauges. For more information see Batching on page 26. Gauge Welcome Screen (BST) Users can adjust the start up screen on their Elcometer 456 gauges via the ElcoMaster™ software - see page 64 for more information. www.elcometer.com 24 R en DFTTECH.COM
  • 26. 7 MEASUREMENT MODES (ST) 7.1 The Elcometer 456 gauges have four measurement modes: Standard (Immediate) Mode (ST): Where readings are taken, rolling statistics calculated (and displayed), but individual values are not stored in the memory. Scan Mode (T): Specifically designed for use with Elcometer 456 Ultra/Scan Probes - see page 79, when Scan Mode is selected, the user can slide the Ultra/Scan Probe over the entire surface area. As the probe is lifted off the surface the average (x), lowest (Lo) and highest (Hi) coating thickness values are displayed. When Batching, each set of three readings can be shown on a Run Chart - see page 17 and stored into memory. Scan Mode with Hold (T):As above but allows the probe to be lifted off the surface for a maximum of 1.5 seconds and replaced without starting a new set of readings - allowing the user to avoid holes, weld seams, etc. inthesubstratewithoutaffectingthemeasurementresults. Auto Repeat Mode (T): When the probe is placed onto the coated substrate inAuto Repeat Mode, the gauge automatically takes readings at a rate of 140 per minute until the probe is removed from the substrate. WhenBatching,eachindividualreadingisstoredintothememory. 7.2 NAVSEA MODE (T): Displays the reading to the nearest 1mil (1µm) above 10mils (254µm) and 0.1mil (0.1µm) below 10mils (254µm). To select NAVSEA mode, press Menu/Setup/NAVSEA or Batch/New Batch/NAVSEA. 4 Scan and Auto Repeat Modes are only available on Elcometer 456 Model T separate gauges. The probe end cap must be fitted to the Ultra/Scan Probe when used in these modes to avoid damage to the probe tip. Use in these modes without the cap will invalidate the probe warranty. Hi, x & Lo www.elcometer.com25 en R 1, 2, .......n DFTTECH.COM
  • 27. 8 BATCHING (ST) Readings can be stored into memory in batches. Batches allow the user to collate readings for easier analysis of large structures or complex assemblies. Elcometer 456 Model T gauges can store a total of 150,000 readings in up to 2,500 batches, the Model S has one batch of up to 1,500 readings. The Elcometer 456 has the following batching functions: Ÿ Create a new batch (ST); Batch/New Batch Ÿ Open an existing batch (ST); Batch/Open Existing Batch Ÿ Rename an existing batch (T); Batch/Edit Batch/Rename Batch Ÿ Copy a batch - including all calibration and limit setups (T); Batch/Copy Batch Ÿ Clear all the readings within the batch - but leaving all calibration and limit setups (ST); Batch/Edit Batch/Clear Batch Ÿ Review the readings, statistics, calibration, batch information (ST) and a graph of the readings (T); Batch/Review Batch Ÿ Delete a Batch (ST), or all batches (T), entirely from the gauge; Batch/Edit Batch/Delete Batch Ÿ Delete the last reading entirely or delete the reading, but mark the reading as deleted in the batch memory (ST) - Batch/Deleted Reading/Delete With Tag and Batch/Deleted Reading/Delete Without Tag respectively. Creating a new batch (T) When using batching for the first time, or when you wish to open a new batch, press Batch/New Batch.The user can now: Ÿ Openthebatchandtakereadings;Batch/NewBatch/OpenBatch1 Ÿ Rename the batch - before opening it via Batch/New Batch/Rename Batch 1. (See Alpha numeric naming Batches & Cal Memories on page 27) www.elcometer.com 26 R en DFTTECH.COM
  • 28. Ÿ Select the appropriate calibration method - Batch/New Batch/ Batch Calibration (see Multiple calibration methods on page 18) Ÿ Choose the type of batch (normal, counted average or IMO PSPC) before opening it via Batch/New Batch/Batch Type (see Batch Types on page 32) Ÿ Set up specific batch limits via Batch/New Batch/Batch Limits (see Limits on page 23) Ÿ Set up a fixed batch size via Batch/New Batch/Fixed Batch Size (see Fixed Batch Size on page 33) Once all the batch settings have been created, press Batch/New Batch/Open Batch 1 - where ‘Batch 1' may now be a re-named as required. Alpha numeric naming batches & cal memories (T) When in batching - or setting up a calibration memory (see Calibration Memories on page 21) - the user can rename the batch or cal memory to a more appropriate name. When a new batch is created, the gauge automatically names it ‘Batch n’ - where ‘n’ is the next unused batch number; e.g. Batch 1, Batch 2, Batch 3, etc. To rename a batch either: Ÿ when creating a new batch press Batch/New Batch/Rename Batch 1; or Ÿ press Batch/Edit Batch/Rename Batch and select the Batch to be renamed from the list of existing batches To rename a calibration memory: Ÿ pressCal/CalMemory1; Cal/CalMemory2orCal/CalMemory3 Ÿ then select Rename Cal Memory n (where n=1, 2 or 3) This then opens up the renaming procedure to enable the user to rename the batch or cal memory. www.elcometer.com27 R en DFTTECH.COM
  • 29. The current name of the batch (or cal memory) is in white in the middle of the display with a yellow ‘cursor’ icon to the right of the name. Using the left arrow, right arrow and Select softkeys, the user can rename the batch or cal memory as required. The yellow, raised character or function is the item that will be ‘chosen’ by pressing the Select soft key. Pressing the Esc softkey at any time cancels the whole operation without making any changes to the original name. To store the re-named ‘name’ highlight OK and press the Select softkey. Character Action OK Stores the name and returns the user to the previous screen Deletes the last character of the name A, B, C... Selects the character A, B or C, etc. Inserts a space 123 Changes the selection characters to: 1 2 3 4 5 6 7 8 9 0 ABC Changes the selection characters to: A B C D E F G H J K L M N O P Q R S T U V W X Y Z ÀÇü Changes the selection characters to: ÀÁÂÃÄÅÆÇÈÉÊËÌÍÎÏÐÑÒÓÔÕÖÙÚÛÜÝÞßµm $%& Changes the selection characters to: ! # ’ £ $ € % & * [ ] _ - + / < > : @ ; ” www.elcometer.com 28 en R DFTTECH.COM
  • 30. Opening an existing batch (ST) By selecting Batch/Open Existing Batch on the Model T, the user will find a list of all the batches that have already been created, together with the number of readings stored in each batch. To open a particular batch use the up and down arrow soft keys and select the appropriate batch. The Elcometer 456 will return the gauge to the main reading screen and the selected batch name will be shown at the top of the display (together with a unique gauge batch id number - allowing no two batches to have exactly the same name). As the Model S only has one batch, the batch will open automatically. Copying an existing batch (T) By selecting Batch/Copy Batch the user will find a list of all the batches that have already been created, together with the number of readings stored in each batch. To copy a particular batch use the up and down arrow soft keys and select the appropriate batch. The Elcometer 456 will then copy all the batch settings - calibration and foil values, batch type, cal method, warning limits, and the batch name - and then ask the user whether they wish to rename the batch. Pressing the Yes softkey the user will then be asked to rename the batch using the renaming procedure described on page 27. Pressing the No softkey (or pressing the Esc softkey whilst in the renaming procedure) will make the Elcometer 456 copy the existing batch name to the new batch - thereby two batches will have the same batch name. Copying a batch does not copy the individual readings within that batch. Clearing an existing batch (ST) By Selecting Batch/Edit Batch/Clear Batch on the Model T, the user will find a list of all the batches that have already been created, together with the number of readings stored in each batch. To clear a particular batch’s individual readings only, use the up and down arrow soft keys and select the appropriate batch. www.elcometer.com29 en R DFTTECH.COM
  • 31. As the Model S only has one batch, it is selected automatically. After a request for confirmation, the gauge will clear the readings from the selected batch and return the gauge to the list of batches (T) or the Batch Menu (S). To clear another batch (T), repeat the procedure. To return the gauge back to the previous menu, press the Back softkey. The user can clear all batches via Batch/Edit Batch/Clear Batch/All Batches (T). Reviewing an existing batch (ST) By selecting Batch/Review Batch the user will find a list of all the batches that have already been created, together with the number of readings stored in each batch. To review a particular batch use the up and down arrow soft keys and select the appropriate batch. As the Model S only has one batch, it is selected automatically. The Elcometer 456 will then open up the Review Batch menu, allowing the userto: Ÿ Review the statistics of the batch Ÿ Review the batch information, including: Ÿ the date and time the batch was created Ÿ the batch type - normal, counted average or IMO PSPC Ÿ the probe type and serial number used to take the readings Ÿ the calibration method - smooth, rough/2 point, etc. Ÿ the batch limits (if set) Ÿ Review the batch’s calibration information, including: Ÿ the date and time the batch was last calibrated or verified Ÿ the substrate type (or types if using an FNF probe) Ÿ the probe type and serial number Ÿ the calibration method - smooth, rough/2 point etc. Ÿ the foil values used in the calibration Ÿ Review the individual readings.The Elcometer 456 displays: Ÿ the readings in numerical order, the first reading is at the top Ÿ the substrate, time and date of measurement Ÿ icons indicating a reading above “ ” or below “ ” the limit Ÿ deleted readings icon “ ” is displayed if “Delete With Tag” selected, (see page 26 for more information). Ÿ Review a graph of the individual readings (T), see page 31. www.elcometer.com 30 en R DFTTECH.COM
  • 32. Batch Readings Graph (T) By selecting Batch/Review Batch/Batch Graph the user can review all readings in the selected batch as a graph. Up to five horizontal axes can be displayed representing different values / statistics as follows: Ÿ Highest reading in the batch “ ” Ÿ Lowest reading in the batch “ ” (for batches of more than one reading) Ÿ Mean of readings in the batch “ ” (for batches of more than one reading) Ÿ High limit for the batch “ ”(when enabled) Ÿ Low limit for the batch “ ”(when enabled) The readings are displayed as white or red vertical bars; white if a reading is within limits (or no limits have been set), and red if outside set limits. Iftherearemorereadingsinthebatchthancanbe displayedonasinglescreen,multiplereadingswill becombinedintoonebar.Shouldasinglereading within the ‘combined bar’ be outside the enabled limits,thewholebarwillbered. Pressing the Zoom+ softkey, allows each individual reading to be displayed, thereby showing the individual readings outside the limits. When zoomed in, the graph will always display the first 25 readings. Pressing the ç softkey will display the last 25 readings taken. Subsequent presses of the ç softkey will scroll backwards, pressing the è softkey will scroll forwards through the readings, 25 readings at a time. Pressing the Zoom- softkey returns to the original overview graph of all readings in the batch. ToreturnthegaugetotheBatchReviewmenu,presstheBacksoftkey. www.elcometer.com31 en R DFTTECH.COM
  • 33. Delete an existing batch (ST) By Selecting Batch/Edit Batch/Delete Batch the user will find a list of all the batches that have already been created (T) or a single batch (S), together with the number of readings stored in each batch. To delete a particular batch’s individual readings only use the up and down arrow soft keys and select the appropriate batch. After a request for confirmation, the gauge will delete the selected batch and return the gauge to the list of batches. To delete another batch, repeat the procedure, to return the gauge back to the previous menu, press the Back softkey. The user can delete all batches from the gauge by selecting Batch/Edit Batch/Delete Batch/All Batches (T). Exit Batching (ST) To stop using the Batching Mode and return to the Immediate mode select Batch/Exit Batching. Batch Types (ST) When saving readings into a batch you have a choice of how the readings are managed within the gauge: Normal: Each reading is saved into memory. Press Batch/New Batch/Batch Type and then select Normal. The batch type can only be changed when creating a new batch. Counted Average: The average of a predefined number of readings is saved into memory. For example a counted average of 3 means: The average of [Reading 1 + Reading 2 + Reading 3] is stored as the first measurement saved in the memory. Likewise the average of readings 4 - 6 are stored as the second measurement in the memory, etc. The individual readings within the counted average (1.2.3, 4.5.6, etc.) are not saved. Press Batch/New Batch/Batch Type and then select Counted Average. The batch type can only be changed when creating a new batch. www.elcometer.com 32 en R DFTTECH.COM
  • 34. The Elcometer 456 then asks the user to set the counted average value. Using the up and down arrow softkeys, set the counted average from 2 - 99 and press the Ok softkey. This returns the user to the previous screen. Press the Back softkey to continue setting up the new batch as required before opening the new batch. If Statistics are displayed whilst measuring using the counted average function (CAF) when taking the readings used to calculate the CAF measurement, the gauge will display the rolling statistical calculations of the individual readings until all the readings that go into calculating the CAF measurement are taken. At this point the statistics then display the values of the stored CAF measurements. IMO PSPC: If you are inspecting coating thickness according to the International Maritime Organisations Performance Standard for Protective Coating, selecting the IMO PSPC batch type and then subsequently opening the batch, the gauge automatically: • Asks the user to confirm the NDFT (nominal dry film thickness) value • Sets the statistics to display the relevant IMO PSPC values • Identifies the batch as an IMO PSPC batch for further analysis in the ElcoMaster™ data management software For more information on the IMO PSPC see page 74. For more information on ElcoMaster™ see page 35. Fixed Batch Size (T) When creating a new batch, by selecting Batch/New Batch and checking the Fixed Batch Size radio button, users can pre-define the number of readings that are to be stored into the batch (between 1 and 255) using the up and down arrow softkeys. Once the batch has been opened and readings are being taken, the Elcometer 456 will notify the user when the fixed batch size is complete and ask if another batch is to be opened. If the user selects No, then the gauge closes the batch and exits batching - returning the gauge to the Standard (Immediate) mode. www.elcometer.com33 en R DFTTECH.COM
  • 35. If the user selectsYes, then the gauge automatically: Ÿ Appends a ‘_1' to the original batch name Ÿ Opens a new batch - copying all the batch setup and calibration information Ÿ The new batch is named as the original batch, with a ‘_2' For example: Ÿ Afixed batch is created and named “ComponentA”. Ÿ When the batch is full, a new fixed batch ‘Component A_2’ is created Ÿ ‘ComponentA’becomes ‘ComponentA_1’ Appending the batch name in this way allows the user to quickly identify - or link - similar batches together. Once a fixed batch size batch has been filled, no additional readings can be added to that batch; a partially completed fixed batch size batch, however, can be re-opened and completed at a later date. To continue a batch link, press Batch/Open Existing Batch and select the last batch in the link. If the batch is full, the gauge will prompt the user to open a new batch before continuing. If the batch is partially complete the user can complete the batch before continuing to a new batch. When downloading linked batches into ElcoMaster™; the original batch name will be displayed (Component A in the above example). Selecting this batch name will download all linked batches into ElcoMaster™ at the same time. For more information on downloading batches see page 44. Note: Once a fixed batch size batch has been created and data has been stored into the memory, the user cannot rename the batch name within the gauge. The batch name can be amended using the ElcoMaster™ software. www.elcometer.com 34 en R DFTTECH.COM
  • 36. 9 DOWNLOADING DATAUSING ELCOMASTER™ (BST) Measurements from the Elcometer 456 Models B, S and T can be downloaded to a computer using the ElcoMaster™ software (supplied with Model S and T gauges, downloadable from the Elcometer website for Model B gauges), or the older versions of ElcoMaster™. This instruction book explains how users can download data using ElcoMaster™. Installing ElcoMaster™ To install ElcoMaster™ insert the supplied mini-CD into your CD ROM drive. The software will automatically begin the install procedure. If it does not, or you have downloaded the software from the Elcometer website, run the SetupElcoMaster2.exe file. The ElcoMaster™ Setup Wizard will then begin. Follow the on screen wizard www.elcometer.com35 en R DFTTECH.COM
  • 37. It is important to read the License Agreement carefully and if the terms are acceptable, select the ‘I accept this agreement’ radio button and click ‘Next >’ ElcoMaster™ will automatically select a default destination location for the software to be installed. Click the ‘Browse...’ button to select an alternate file location. Click ‘Next >’to continue Choose any additional tasks, by selecting the appropriate check box and press ‘Next >’ to continue www.elcometer.com 36 en R DFTTECH.COM
  • 38. The ElcoMaster™ wizard now provides a list of the settings that have been selected. Click ‘Install’ to undertake the installation or ‘< Back’ to review or alter any settings. ElcoMaster™ will now install. Press ‘Finish’to exit Setup. Upgrading data from older version of ElcoMaster™ ElcoMaster™ is fitted with an internal database upgrade facility which will automatically check to see if there are any original ElcoMaster™ database files and ask if the user would like to upgrade the data to the new ElcoMaster™ format. Upgrading can occur at any time by selecting Menu/Import/Import ElcoMaster 1.x Data and selecting the relevant database file. www.elcometer.com37 en R DFTTECH.COM
  • 39. The ElcoMaster™ Software ElcoMaster™ is a simple - yet powerful - data management software solution that has been designed to allow users to generate professional reports in seconds - with the minimum of fuss. It has three operating modes; Excel Link, Standard and Advanced Mode. ElcoMaster™ is set to Standard Mode on first install. Across the top of the software is a Menu button, ‘Action Tabs’ and an expand arrow. Pressing the Menu button opens up a drop down list of options: Ÿ Help : Provides Elcometer contact details and information about ElcoMaster™. Ÿ Update : Provides users with: Ÿ the ability to update the ElcoMaster™ software to the latest release - connection to the internet is required for this function. Ÿ the ability to upgrade the firmware of the: Ÿ Elcometer 224 Digital Surface Profile Gauge (Model B &T) Ÿ Elcometer 456 Digital Coating Thickness Gauge (Model B, S &T) Ÿ Elcometer 130 Salt Contamination Meter (Model S &T) www.elcometer.com 38 en R Menu Button Action Tabs Expand Arrow DFTTECH.COM
  • 40. www.elcometer.com39 en R Ÿ Import: Allows users to import a database from an earlier version of ElcoMaster™- version 1.x (not applicable to the new Elcometer 130) Ÿ Exit: Allows users to shut down the software The Action Tabs available depend on the operating mode in use as follows: Excel Link Mode Ÿ Settings : Allows users to adjust: Ÿ The language of ElcoMaster™ Ÿ The units of measurement by gauge type Ÿ Customise the default reports to include a user logo or image, together with footer information Ÿ Adjust the normal distribution type for the histogram chart Ÿ Alter the colour settings of the user interface Ÿ The text file separator used when exporting files Ÿ Select an alternate location to store the database Ÿ Enable or disable the auto update option (where access to the internet is prohibited). Ÿ Download: Allows users to connect all their Elcometer gauges ®via USB, Bluetooth , or RS 232 where appropriate. Standard Mode: All the features of Excel Link Mode plus; Ÿ View: Allows users to: Ÿ View measurement data, gauge information, measurement statistics, set limits, add notes and labels and view photographs and other documents Ÿ Print, email or PDF standard reports Ÿ Export data to Excel or other software packages as required Ÿ Archive (and restore) old data DFTTECH.COM
  • 41. Ÿ SavedReports: Once a user has generated a PDF report from within the View action tab, the report is automatically saved within the Saved Reports action tab - for reference and review. Advanced Mode: All the features of Excel Link and Standard Mode plus; Ÿ Design custom reports Ÿ View data in standard forms - predefined within the Design Report action tab or by Elcometer. Ÿ Design a collection template to guide inspectors where, and in which order, readings should be taken - see page 46 for further details. Users can switch between operating modes at any time by pressing the ExpandArrow and selecting the mode required. en R www.elcometer.com 40 DFTTECH.COM
  • 42. Clicking ‘Connect Gauge’ starts t h e E l c o M a s t e r ™ G a u g e Connect Wizard. T h e E l c o M a s t e r ™ d a t a management software allows users to download readings from a wide range of Elcometer inspection gauges. Measurements such as surface profile, surface cleanliness, temperature, dewpoint, delta T, gloss, material thickness and dry film thickness can all be downloaded, stored and reported usingtheElcoMaster™software. These instructions will inform the user how to download data from an Elcometer 456 coating thickness gauge. All appropriate Elcometer gauges can be downloaded in a similar way. Ÿ Select the Dry Film Thickness tab and press ‘Next >’ ElcoMaster™ supports the new Elcometer 456 (identified in the software as Elcometer 456/4) and the Elcometer 456 Mk 3 (Elcometer 456/3). Ÿ Select the Elcometer 456/4 tab and press ‘Next>’ Connecting an Elcometer gauge to ElcoMaster™ (BST) In order to download any gauge readings from the Elcometer 456 the user must first ‘Connect the gauge’ by clicking the ‘Connect Gauge’ button on the Download action tab. www.elcometer.com41 en R DFTTECH.COM
  • 43. Ÿ Select the appropriate connection method for the gauge Elcometer 456 gauges come supplied with Bluetooth (Models S & T) and USB (Models B, S & T) data output. Users can purchase a USB B l u e t o o t h A d a p t o r f r o m Elcometer (Part number T99924797) which will provide a Bluetooth solution to computers without internal bluetooth fitted. If ElcoMaster™ is installed onto a computer without Bluetooth c a p a b i l i t y, h o w e v e r, t h e Bluetooth tab is greyed out (as displayed in top image). Ÿ Select the appropriate connection method Ÿ Switch on the Elcometer 456 Ÿ Connect the USB cable or make sure that Bluetooth is switched on in the gauge via Menu/Bluetooth/Enable Bluetooth (S & T) Ÿ Bluetooth users should return their gauge to the main r e a d i n g s c r e e n b e f o r e continuing Ÿ Press ‘Next >’ Ÿ A f t e r a s c r e e n p r o m p t ElcoMaster™ will search for and list all Elcometer 456 gauges. en R www.elcometer.com 42 DFTTECH.COM
  • 44. Each coating thickness gauge connected is now listed. Ÿ Select the appropriate gauge and press ‘Next >’ If connecting via Bluetooth, the gauges are identified using the Bluetooth ID - which can be seen o n t h e b o t t o m o f t h e Menu/Bluetooth screen. Connecting via Bluetooth now requires the gauge to be ‘Paired’ by keying in the gauge’s unique Bluetooth PIN Code. This code can be found on the bottom of the Menu/Bluetooth screen. Ÿ Type in the Bluetooth PIN Code and press ‘Next >’ (See Section 10 on page 56 for information on connecting via Bluetooth to a mobile device using ElcoMaster™ MobileApps.) ElcoMaster™ will now validate the connection, press Finish when complete. The gauge is now connected and ElcoMaster™ will return the user to the Download action tab, and display the connected gauge. The same gauge can be connected by more than one method. Repeat the ‘Connect Gauge’ and follow the onscreenprompts. By clicking on the Edit button, users can Delete the gauge from ElcoMaster™, name the gauge by a more familiar identification (Enter a User ID) or set up the gauge power up display screen (Change the Welcome screen). See Changing the Welcome Screen on page 64. en R www.elcometer.com43 DFTTECH.COM
  • 45. The Download Wizard will now guide the user through the simple download readings process. ElcoMaster™ allows users to download their gauge readings: Ÿ Directly into ElcoMaster™ Ÿ D i r e c t l y i n t o a n E x c e l Spreadsheet, bypassing ElcoMaster™ Ÿ into a text file for use in other software programs, or Ÿ into a CQATK XMLfile Ÿ Select the appropriate option Ÿ Select or create a new project folder as required (ElcoMaster™ Batch File users) Users wishing to export directly into Excel will also be asked to select a single or multiple spreadsheet option. Single; all batches selected will be downloaded into a single spreadsheet. Multiple; each batch will be downloaded into a separate spreadsheet tab. Ÿ Selectoneormoreindividualbatches orclickon‘AllFiles’andpress‘Next>’ Downloading Data from the Elcometer 456 (ST) Once the gauge has been connected to ElcoMaster™ (see pages 41-43), switch on your gauge and click the ‘Download from Gauge’ button for the relevant gauge and connection method. When downloading data into ElcoMaster™ (as opposed to directly into a spreadsheet or a text file), downloaded data is stored in Projects - allowing users to clearly identify inspections. en R www.elcometer.com 44 DFTTECH.COM
  • 46. The User will be asked to select a project name from the list. Alternatively the user can create a New Project name. Ÿ Select or create a new project and press ‘Next >’ To download readings from the gauge: Ÿ Select a single or multiple batches from the list or click on ‘All Files’ as required, then press ‘Next >’ Ÿ Select or create a new folder to save the gauge’s data to In some cases users may have re-used an existing batch name in the gauge. The user should now chose either to select: Ÿ Rename Duplicate Files Ÿ RenameAll Files, or Ÿ Overwrite Existing Files Ÿ Select as required and press ‘Next >’ The selected batches will now download. Once the data download has been completed, the user can check the ‘View Files’box and click ‘Finish’. Alternatively, click ‘Finish’ and select the ‘ViewActionTab’ en R www.elcometer.com45 DFTTECH.COM
  • 47. Viewing Data in ElcoMaster™ ElcoMaster™ not only allows users to view and analyse data from a wide range of Elcometer gauges, but also allows users to manually input data as required. This instruction book provides a brief summary of some of the features of ElcoMaster™, however users should read the ElcoMaster™ help file for a complete guide. Data Tree Command Tabs Template Tabs Live Reading Tab Measurement Data Window Graph Window en R www.elcometer.com 46 DFTTECH.COM
  • 48. By selecting the View Action Tab, users can instantly see their data. The ViewActionTab can be broken down into 6 distinct areas: Ÿ Data Tree Batches can be stored within folders ( ) in unique Project files ( ). By clicking on the Project filename, users can then completeuniqueprojecttagsandbatchtagsasrequired. Eachbatchofdataisidentifiedbythetypeofinspection: Climate Batch Surface Profile Batch Surface Cleanliness Batch Dry FilmThickness Batch Material / Ultrasonic NDTBatch Clicking the computer mouse’s right button over a file orfolderprovidestheuserwiththefollowingfunctions: Ÿ New: Allows users to: Ÿ create a new Project ( ) Ÿ create a new Folder ( ) Ÿ import an Image ( ) Ÿ import a PDF Document ( ) Ÿ create a new batch type Ÿ Cut, Copy & Paste: Cut, copy & paste inspection files and folders into other files or folders within the data tree. Ÿ Delete, rename & move to: Allows delete, rename or move a file Ÿ Combine & Split: Combine batches of the same type or split a batch into equal sizes or of equal time Ÿ Archive & Restore: Archive and restore inspection data Ÿ Print, PDF, Email & Export: Print, generate a PDF or export to Excel or a tab separated text file; the selected batch report en R www.elcometer.com47 DFTTECH.COM
  • 49. Ÿ Command Tabs There are 6 command tabs, which are the key functions required by the user. Ÿ New: Allows users to: Ÿ create a new Project ( ) Ÿ create a new Folder ( ) Ÿ import an Image ( ) Ÿ import a PDF, .edf, .txt. Document ( ) Ÿ create a new batch type Ÿ Move to: Moves the selected items to a different folder or to a different page Ÿ Print: Prints a report of the selected items Ÿ PDF: Generates a PDF report of the selected items Ÿ Email: Generates a PDF report of the selected items and attaches it to an email Ÿ Export: Ÿ Allows the user to export the selected items into Excel or as a text or CQATK XMLfile en R www.elcometer.com 48 DFTTECH.COM
  • 50. Ÿ Template Tabs & Graph Window There are currently 2 graphs within ElcoMaster™; individuals and histogram. Clicking a template tab displays the relevant graph in the Graph Window When the Individuals Graph is displaying climate data, additional tabs appear on the right hand side, allowing the user to select a measurement to view from the following: RH: Relative Humidity Ts: SurfaceTemperature Ta: AirTemperature Td: DewpointTemperature TΔ: DeltaT, (Ts-Td) Tdb: Dry BulbTemperature Twb: Wet bulbTemperature SH: Specific Humidity Right mouse click on the individuals graph allows users to select the x-axis value between: Date &Time RelativeTime (seconds) Reading Number RelativeTime (minutes) Left clicking and dragging the mouse across the individuals chart allows users to zoom in on a specific area of the graph. The zoom can be reset by clicking on the icon. en R www.elcometer.com49 DFTTECH.COM
  • 51. Ÿ Measurement Data Window The measurement data window provides the user with a range of information under 7 tabs: Ÿ Details Provides useful information about the measurement gauge, serial number, batch name, date the batch was created, date and time of the first and last reading, etc. Ÿ Statistics Provides the user with a wide range of statisitical calculations - mean, minimum and maximum reading, standard deviation, ±3σ, coefficient of variation, relevant information regarding the IMO PSPC analysis (coating thickness gauge readings only). Users can display the values on the graph by clicking the ( ) icon and selecting a colour. Ÿ Measurements Displays all the individual readings. Users can alter the display order (Date & Time, Relative Time (seconds), Relative Time (minutes) and Reading Number) by clicking on the column title. Individual measurements can be excluded/ included by right clicking on the specific measurement within the table. Measurements can also be amended by overtyping the relevant reading. Comments can be added to any measurement by clicking on, and then typing into, the relevant cell within the comments column. Ÿ Limits Shows any limits that were used whilst taking the readings or allows users to apply limits. When set, measurements outside the limits are highlighted within the measurement tab. Users can display the values on the graph by clicking the ( ) icon and selecting a colour. en R www.elcometer.com 50 DFTTECH.COM
  • 52. Ÿ Measurement Data Window (continued) Ÿ Notes Type and format a comment or note regarding the batch. Ÿ Labels When a project has been set up with individual Project and Batch labels users can amend or input the appropriate details. Project labels are applied to each file, folder and batch within the project; Batch labels apply to a specific batch. Both project and batch labels are fully user definable, however examples of project and batch labels are listed below: Project Label Examples: Client name, Structure name, Structure location, Batch Label Examples: Inspector name, shift number, area under consideration, strutt number, etc. Ÿ Photos Photographs of the area under inspection, specific defects, etc can be attached to the measurement batch - simply by clicking the ( ) icon within the Photos tab. Descriptions or comments can be added below each image added. Double clicking on any photo opens up a view window allowing the user to copy the photo to clipboard (for pasting in another program, or save the photograph to another file. Data, photographs, labels etc. added within the measurement window tabs is automatically included on any reports, exports, pdf and emails generated. en R www.elcometer.com51 DFTTECH.COM
  • 53. Ÿ Live Gauge Readings (BST) ElcoMaster™ allows users to transfer data from a gauge as the readings are taken, to be stored in a batch within ElcoMaster™. Live gauge readings can be recorded via Bluetooth (ST) or USB (BST) connections Once the gauge has been connected to ElcoMaster™ (see pages 41-43), switch on your gauge and click the ‘Live Readings’ button on the View ActionTab Ÿ Select the appropriate batch (or create a new batch) for the readings to be recorded into ElcoMaster™ will now open up the Live Readings display, and ask the user to ‘ Connect Gauge’ Ÿ Click on the Connect Gauge Ÿ Select a gauge from the list Ÿ Select the relevant connection method (if more than one connection method has been set up (see pages 41-43) ElcoMaster™ will then link with the selected gauge and, when ready display the gauge information within the Live Readings window. Ÿ At any time the user can select a different batch to change where the next reading is taken. Ÿ Click the button or switch of the gauge to disconnect en R www.elcometer.com 52 DFTTECH.COM
  • 54. Ÿ Click on the Design Collect tab and select an existing template or click ‘New Design’ When creating a new design you will be asked to: - Enter a name and description - Select the Batch Type; Profile, Material Thickness, DFT or Surface Cleanliness - Add the required image to collect readings against - Specify the number of readings to be collected - Enter relevant Limits - Request a prompt to begin the next set of readings or begin automatically - Choose to create a new batch for each set of readings or create a single batch with multiple reading sets Ÿ Click ‘Finish’to begin the design To design the ‘collect’ image sequence, simply click and hold each 'reading' circle in turn, drag onto the image where readings are to be taken and adjust the size accordingly. Once complete click ‘Save’ and click the 'X' button in the top right to close the design window. Ÿ Design Collect The ‘Design Collect’ function allows users to set up a collection template to guide Inspectors where, and in which order, readings should be taken. This image can be used as a collection guide in ‡ ElcoMaster™ or transferred to an Android mobile phone or tablet using ElcoMaster™ forAndroid™, see pages 55 - 56. ‡ To use Design Collect, switch ElcoMaster™ to Advanced Mode by clicking on the Expand Arrow, and selecting ‘StartAdvanced Mode’. www.elcometer.com53 en R DFTTECH.COM
  • 55. Using a Collect Design Ÿ Select the ‘View’tab Ÿ Select a folder or project and click the ‘New’button Ÿ Move the cursor to relevant batch type, an additional window will appear, select the required Collect Design A new batch will be created. Unlike standard batches it will have an additional tab with the same name as the Collect Design, click on this to show your design.To begin collection, Ÿ Click on ‘Connect Gauge’in the ‘Live Readings’window a Ÿ Select a gauge from the list Ÿ Select the relevant connection method ElcoMaster™ will link the selected gauge and, when ready, display the gauge information within the Live Readings window. Once connected, green arrows will flash around the first ‘reading’ circle to measure. When a measurement is taken, the ‘reading’ circle will change to b show the measured value , and the green arrows will move to the next reading. a The gauge must be connected to ElcoMaster™ before it will appear in the list, see pages 41 - 43. b The ‘reading’circle will be green if the measurement is within set limits and red, if outside limits. en R www.elcometer.com 54 DFTTECH.COM
  • 56. 10 ELCOMASTER MOBILEAPPS (ST) Ideal when out in the field or on-site, live readings can be stored directly onto a mobile device and saved into batches. Inspection data can be transferred from mobile to PC for further analysis and reporting. ElcoMaster™ MobileApps features include: Ÿ Store live readings directly on to a mobile device and save into batches. Ÿ Download batches straight to a mobile device allowing data analysis immediately on site. Ÿ Transfer inspection data to PC for further analysis and reporting. Ÿ Analyse data via sequential readings, statistics, charts & histograms or on images. Ÿ Download collection images created using the 'Design Collect' function within ElcoMaster™ to indicate where and in which order readings should be taken. Ÿ Take photographs and add them to batch readings at the click of a button. Ÿ Map readings on to maps, photographs or diagrams. en R www.elcometer.com55 DFTTECH.COM
  • 57. en R www.elcometer.com 56 Connecting via Bluetooth to a Mobile Device To use ElcoMaster™ Mobile Apps, the Elcometer 456 gauge must be 'paired' with mobile device via Bluetooth: 1. Switch on the Elcometer 456 and ensure that Bluetooth is enabled via Menu/Bluetooth/Enable Bluetooth. Return the gauge to the main reading screen before continuing. 2. Switch on the mobile device and enable Bluetooth (usually via 'Settings' – refer to the operating instructions for the mobile device). 3. The mobile device will search for and list all Elcometer 456 gauges with Bluetooth enabled. Each gauge is identified as “E-456/4“ followed by the serial number. 4. Select the Elcometer 456 gauge required. The mobile device now will attempt to 'pair' with the selected gauge. 5. A 'Bluetooth' pairing request will appear on both the mobile device and gauge. Accept the pairing request on both. The mobile device and Elcometer 456 gauge are now 'paired'. Compatible with smart phones and tablets running Android 2.1 or above. To install, download via www.elcometer.com or using the Google Play™ Store app, and follow the on screen instructions. Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPhone 4, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (4th and 5th generation). To install, download via www.elcometer.com or the App Store, and follow the on screen instructions. DFTTECH.COM
  • 58. 11 CLOUD COMPUTING WITH ELCOMASTER (ST) ElcoMaster™ is now compatible with Cloud Computing. Ÿ Create a Cloud account via a Cloud service provider e.g. Dropbox, Google Drive™, Skydrive or your own cloud based FTP server. Ÿ All approved users of the cloud account will have instant access to all inspection data in real time. Ÿ Data can be accessed by authorised users via secure log-in from any computer or mobile device anywhere in the world via ®Bluetooth , USB, WiFI or 3G/4G. Ÿ Using the ElcoMaster™ instant messaging feature, job instructions can be sent or stored in specific job files. Ÿ Wherever you are in the world, ElcoMaster™ Mobile allows you to instantly upload to the cloud via 3G/4G or WiFi. en R www.elcometer.com57 DFTTECH.COM
  • 59. 12 GETTING THE MOST OUT OF ELCOMASTER ElcoMaster™ has been designed to be a very intuitive method of developing professionalreports,itishoweverextremelyversatile.Herearejustafewways ElcoMaster™canbeusedintheday-to-dayactivitiesofacoatingprofessional. 1. Gauge to PC to Excel Transferring inspection data straight into Microsoft Excel via Bluetooth® or USB is simple and easy. 4. Upload to a cloud for real time analysis anywhere Using ElcoMaster™ Mobile App you can upload inspection data, photos, notes and GPS coordinates direct to a Cloud account of your choice via 3G/4G or WiFi. All data is instantly visible to other approved users of the account - through a secure log-in on any computer or mobile device anywhere in the world. 2. Gauge to PC data transfer into ElcoMaster™ ® Using Bluetooth or USB, ElcoMaster™ transfers inspection data in seconds, archiving data and generating reports at the click of a button. 3. ElcoMaster™ Mobile App for immediate data transfer from site to office Transfer inspection data straight to ® mobiles and tablets via Bluetooth when on site for instant analysis, then e-mail them back to the office for storing, review and QA reporting. 5. Seamlessly link multiple sites or production lines ElcoMaster™ gives you real time quality control monitoring from multiple inspection projects in any location. You can compare and combine inspection data from different production lines or different locations, to produce specific Project Inspection Reports quickly and easily. en R www.elcometer.com 58 DFTTECH.COM
  • 60. 12 GETTING THE MOST OUT OF ELCOMASTER Real time collaboration for multi-site projects When working with manufacturers of sub-assemblies across the globe ElcoMaster™ can collate all inspection data from each site, assembly line and project into one shared location. Contractors can then: Ÿ Accept or reject parts before shipment from sub-assembly plants. Ÿ Combine all data from sub assembly and final assembly inspection to generate Project Inspection Reports for quality management, both during and after completion of the project. Ÿ Have real time in progress visibility across the whole project, no matter where the sub-assembly manufacturing is in the world. Ÿ Have multi-site collaboration, real time dialogue and decision making to improve efficiency and quality throughout the production process. Real time communication Featuring instant messaging the ElcoMaster™ Mobile App lets you add messages to inspection data, projects and files, allowing you to immediately discuss key points with your colleagues, managers or clients, send work instructions and store messages within the project file. Your data - your choice - your control ElcoMaster™ allows you to decide which Cloud service provider to use. It is your data, it is secure as only approved users can have access, no third parties can see your data. ElcoMaster™ Mobile App is compatible with a range of cloud service providers and FTP servers including: Google Drive, FTP Server, Dropbox. 6. Real time collaboration for multi-site projects en R www.elcometer.com59 DFTTECH.COM
  • 61. 13 CALIBRATING THE ELCOMETER 456 (EBST) The Elcometer 456 gauge is available in 4 model versions. Each version has a number of calibration methods as below: For full descriptions of each calibration method please see page 19- 20. The Elcometer 456 has on screen instructions to guide the user through each calibration method. Method Model E Model B Model S Model T Factory ■ ■ ■ ■ Rough / 2 Point ■ ■ ■ ■ Zero ■ ■ ■ Smooth ■ ■ ■ Zero Offset ■ ■ Auto ■ ■ Calibrating the Elcometer 456 (Model E) Press the Cal softkey and follow the on screen instructions. a b c d e h g f en R www.elcometer.com 60 DFTTECH.COM
  • 62. To calibrate the Elcometer 456 Model E on rough surfaces: Ÿ Select two foil values - one above the target dry film thickness value (thick) and one below (thin) Ÿ Follow the on screen instructions Ÿ more than one reading can be taken on each foil value - the average of the readings is displayed (screens c and g on page 60). Ÿ To calibrate the Elcometer 456 Model E on smooth surfaces: Ÿ Select a foil value which is above the target dry film thickness value (thick) and the uncoated base substrate (thin). Ÿ When the gauge instructs the user to place the gauge onto the thin foil (calibration step 2), place the probe on the uncoated base and adjust the thickness value to 0.0µm (mils) To calibrate the Elcometer 456 Model E using the Factory calibration: Ÿ Select either Menu/Reset/Metric Gauge or Menu/Reset/Imperial Gauge. Taking multiple readings on each foil will increase the accuracy of the calibration. Calibrating the Elcometer 456 (BST) Ÿ Press the Cal softkey to open the Calibration menu Ÿ As the Elcometer 456 Model B, S and T have multiple calibration methods; Ÿ if the Calibration Method icon displayed is as required, press the Select softkey and follow the on screen instructions Ÿ the user can amend the calibration method, by selecting the appropriate method from within the Cal/Cal Method menu and press the Select softkey before selecting Calibrate from the Calibration menu en R www.elcometer.com61 DFTTECH.COM
  • 63. Ÿ to select the factory calibration press Cal/Factory Calibration Ÿ The factory calibration returns the gauge to the calibration set up during manufacture and final test. The factory calibration is a smooth surface calibration using factory reference probes Ÿ When the correct calibration method has been selected, press Cal/Calibrate and follow the on screen instructions. Ÿ Taking multiple readings on each foil will increase the accuracy of the calibration. Note: Auto, ISO, SSPC PA2, Swedish and Australian cal methods - where available - can only be selected whilst in batching as memory is required. Testing (BST) & Validating (ST) Calibrations Ÿ The calibration of any Elcometer 456 B, S or T gauge can be checked at any time, without affecting any statistics or batch memory. Ÿ By selecting Cal/Test Calibration the user can check the calibration of the gauge by comparing the reading value displayed versus the measured foil or coated standard value. (ST) Ÿ Pressing the Validate Softkey will update the date and time of the last calibration. (ST) Each batch can have its own unique calibration, simply calibrate each batch independently. For more information on Batching see page 23. en R www.elcometer.com 62 DFTTECH.COM
  • 64. Calibration lock (BST) To avoid accidental amendments to the calibration settings switching on the Cal/Calibration Lock feature’ locks’ the user from undertaking any changes to the calibration without first un-checking the Cal/Calibration Lock feature. When the Calibration Lock is enabled, users can still test the calibration via Cal/Test Calibration but will be unable to validate or re-calibrate the gauge. The calibration can also be locked using a PIN Code. Locking & Unlocking the Calibration Lock using a PIN Code (BST) To unlock the calibration: Ÿ Press the Cal softkey and select Calibration Lock éŸ Enter the four digit PIN Code, if set, using the softkeys to selectê † 0 to 9 and the è softkey to move from the first to the fourth digit Ÿ Press Ok or Escape to cancel To disable the calibration lock PIN Code: Ÿ Press the Menu softkey and select Setup/Calibration Lock Ÿ Enter the four digit PIN Code 4 Should the user forget or loose the PIN code, the PIN can be disabled via ElcoMaster™. Using the USB cable, simply connect the gauge to a PC with ElcoMaster™ Version 2.0.34 or higher installed and select Edit/Clear Calibration PIN. † The è softkey will appear when the “ X “ changes to a number. To set a calibration lock PIN code: Ÿ Press the Menu softkey and select Setup/Calibration Lock éŸ Set the four digit PIN Code using the ê softkeys to select 0 to 9 and the è softkey to † move from the first to the fourth digit Ÿ Press Set, Escape to cancel or Adjust to amend the PIN code en R www.elcometer.com63 DFTTECH.COM
  • 65. 14 CHANGING THE WELCOME SCREEN (BST) Each time the Elcometer 456 gauge is switched on, the Elcometer logo is displayed. Users can add their own logo, image or identification details as required via ElcoMaster™. Once the gauge has been connected to ElcoMaster™ (see pages 41-43), to add a user welcome screen Ÿ Switch on your gauge Ÿ Select the DownloadActionTab Ÿ Click the ‘Edit’ button on the right hand side of the appropriate gauge Ÿ Select ‘Change Welcome Screen’ from the drop down menu Ÿ Select the required image, and or add user specific text and press ‘Next >’ Ÿ Select ‘Stretch Image’ or ‘Centre Image’ as required and press ‘Next >’ Ÿ Select the appropriate connection method and press ‘Next >’ ElcoMaster™ will now download the selected image into the gauge. This may take some time. en R www.elcometer.com 64 DFTTECH.COM
  • 66. 15 GAUGE FIRMWARE UPDATES (BST) Each time the Elcometer 456 gauge is connected to ElcoMaster™ (see pages 41-43); if the computer has access to the internet, ElcoMaster™ automatically checks to see if there are any gauge firmware updates for the connected gauge. ElcoMaster™ will inform the user when there are any firmware updates available for the connected gauge by displaying the ‘Update Gauge’button. Please note that users can update the gauge firmware via a USB connection only . Clicking the ‘Update Gauge’ button will display a list of the ‘Fixes’ in all the updates that have been released since the gauge’s last upgrade. Ÿ Press ‘Next >’to continue. Warning - updating the gauge firmware will result in all readings, batches, statistics and calibrations being deleted. The gauge will also be returned to the factory default settings. Ÿ Press ‘Next >’ to commence downloading the latest firmware to the Elcometer 456 Warning - Do not switch off the computer or disconnect the gauge during the gauge upgrade. Typical firmware updates include gauge enhancements, amendments, language updates, etc. Users cannot upgrade a Model B to a Model S for example, nor can a ferrous gauge be upgraded to a dual ferrous/non- ferrous gauge. en R www.elcometer.com65 DFTTECH.COM
  • 67. 16 GAUGE ICONS & ERROR CODES (EBST) Icon Description Model Number of Readings BST Mean (average) BST Standard Deviation BST Highest Reading BST Lowest Reading BST Coefficient of Variation BST Elcometer Index Value (EIV) BST NDFT Value (Nominal Dry Film Thickness) ST Percentage of readings greater than or equal to the NDFT Value ST Percentage of readings between 0.9 x NDFT and the NDFT value ST 90/10 Rule Pass ST 90/10 Rule Fail: 90% of readings are greater than the NDFT value ST 90/10 Rule Fail: At least one measurement is below 0.9 x NDFT. (If a number between 1 and 10 is displayed, insufficient measurements have been taken to be statistically valid) ST Counted Average (when not in Batching) BST High and Low Limit Set ST Low Limit Set ST High Limit Set ST Number of readings above Limit ST Number of readings below Limit ST en R www.elcometer.com 66 DFTTECH.COM
  • 68. Icon Description Model Zero Calibration Method BST Smooth Surface Calibration Method BST Rough/ 2 Point Calibration Method EBST Zero Offset Calibration Method ST Auto Calibration Method ST ISO 19840 Calibration Method ST SSPC PA2 Calibration Method ST Swedish Standards Calibration Method ST Australian Standards Calibration Method ST Calibration Check T Reading outside Calibration T Calibration Lock BST Calibration Icon Description Model Low Limit Set: Reading outside Low Limit ST High Limit Set: Reading outside High Limit ST Low & High Limit Set: Reading outside Low Limit ST Low & High Limit Set: Reading outside High Limit ST en R www.elcometer.com67 DFTTECH.COM
  • 69. Icon Description Model Auto Repeat Mode T Scan Mode T Scan Mode with Hold T Icon Description Model Bluetooth Not Connected ST Bluetooth Connected ST USB Connected BST Ferrous Probe on Ferrous Substrate EBST Non-Ferrous Probe on Non-Ferrous Substrate BST Dual FNF Probe on Ferrous Substrate EBST Dual FNF Probe on Non-Ferrous Substrate EBST Battery Life Indicator EBST Replace Batteries EBST User Selectable Feature: Switched Off EBST User Selectable Feature: Switched On EBST Beep Volume Setting EBST General Icon Description Model Batch Type: Normal ST Batch Type: Counted Average ST Batch Type: IMO PSPC ST Deleted Reading - Tagged ST Batching en R www.elcometer.com 68 Measurement Modes DFTTECH.COM
  • 70. Message Cause / Action #1 - Probe Probe to gauge communication failure. Integral Gauges: Contact Elcometer. Separate Gauges: Remove probe and refit. If error persists, contact Elcometer. #2 - Probe Corrupt data output from probe. Integral Gauges: Contact Elcometer. Separate Gauges: Replace probe. If error persists, contact Elcometer. #3 - Probe Internal Error - contact Elcometer. Probe Unsupported No probe connected. Connect probe. Probe is Dual FNF but gauge is ferrous or non-ferrous only or Mk 3 probe is being used with a Mk 4 gauge. Use correct probe. Probe Changed Probe has been changed during a calibration procedures. Calibration adjustment required. Unstable Reading External electromagnetic interference or gauge is faulty. Isolate from electromagnetic interference. If error persists, contact Elcometer. Value Too Large Calculated value is too large to be displayed. Contact Elcometer. Calibration Error Incorrect calibration calculation. Re-calibrate. If error persists, contact Elcometer. Bluetooth PC Reply Bluetooth link working at limit of its range. PC is busy running other applications. Interference. PC application doesn’t send replies. Move gauge closer to PC. Shutdown other applications. Remove source of interference. If error persists, contact Elcometer. Error - EEPROM Write Gauge EEPROM communication error. If problem persists, EEPROM is faulty. Error Codes Under certain conditions, the gauge will display error messages. These message are cleared by pressing any key. The cause of the error should be corrected before proceeding. en R www.elcometer.com69 DFTTECH.COM
  • 71. TimeandDate SetTime SetDate SetFormat DisplayTimeandDate 17 GAUGE MENU STRUCTURES (EBST) Please find below a simplified diagram of each Elcometer 456 model’s menu structures. Elcometer 456 Model T MeasurementMode StandardMode AutoRepeatMode ScanMode ScanModeWithHold Setup Units Language TimeandDate BeepVolume ScreenSettings Probe MeasurementMode GaugeAutoOff CalibrationLock NAVSEAScreenSettings ScreenBrightness ScreenTimeout AutoDisplayRotation OpeningScreen SetLimits EnableLimits SetUpper SetLower SetNDFT Bluetooth EnableBluetooth BluetoothIDxxxxxx BluetoothCodexxxxxx AI About GaugeInformation ProbeInformation Contact Legal BatchLimits EnableLimits SetUpper SetLower SetNDFT BatchType Normal CountedAverage IMOPSPC BatchCalibration Calibrate CalMethod UseCalMemory1 UseCalMemory2 UseCalMemory3 DeletedReading DeleteWithTag DeleteWithoutTag NewBatch OpenBatch1 RenameBatch1 BatchCalibration BatchType BatchLimits FixedBatchSize NAVSEA Menu DeleteLastReading Setup SetLimits Bluetooth About Reset EmergencyLight Calibration Calibrate CalMethod CalMemory1 CalMemory2 CalMemory3 FactoryCalibration CalibrationLock TestCalibration CalibrationCheck Batch MemoryFree NewBatch OpenExistingBatch ExitBatching EditBatch CopyBatch ReviewBatch DeletedReading Display ClearStatistics ReadingsOnly Readings&SelectedStats Readings&RunChart Readings&BarGraph BatchGraph Statistics ○ ReviewBatch Batch1 Statistics BatchInformation CalibrationInformation Readings BatchGraph CalibrationLock EnablePIN Units µm mm mils inch Statistics ClearStatistics ViewSelected ViewAll SelectStatistics CountedAverage EditBatch RenameBatch ClearBatch DeleteBatch † Probe AutoFNF FerrousF NonFerrousN ProbeSwitchOn † Probe FerrousF1 FerrousF2 Legal Patents LegalNotices Regulatory CalMethod Zero Smooth Rough/2Point ZeroOffset Auto ISO SSPCPA2 Swedish Australian ○ ○ ○ ○ ○ ○ CalMethod Zero Smooth Rough/2Point ZeroOffset Auto CalMemoryn Savedhh:mmdd/mm/yy Select Calibrate CalMethod TestCalibration RenameCalMemoryn ViewCalibrationData ClearCalMemoryn wheren=1,2,or3 ○ ○ ○ ○ SelectStatistics AllPSPCValues NumberofReadings Mean LowestReading HighestReading StandardDeviation CoefficientofVariation LowLimitValue NumberBelowLimit HighLimitValue NumberAboveLimit ElcometerIndexValue NDFTValue %>=NDFT %90-100%NDFT IMO90:10Pass/Fail ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ † Menu displayed is dependent on the probe connected en R www.elcometer.com 70 Regulatory QDIDxxxxxx xxxxxx xxxxxx xxxxxx ○ ○ DFTTECH.COM
  • 72. 17 GAUGE MENU STRUCTURES CONTINUED (EBST) Elcometer 456 Model S TimeandDate SetTime SetDate SetFormat DisplayTimeandDate Setup Units Language TimeandDate BeepVolume ScreenSettings Probe GaugeAutoOff CalibrationLock ScreenSettings ScreenBrightness ScreenTimeout AutoDisplayRotation OpeningScreen SetLimits EnableLimits SetUpper SetLower SetNDFT Bluetooth EnableBluetooth BluetoothIDxxxxxx BluetoothCodexxxxxx AI About GaugeInformation ProbeInformation Contact Legal BatchType Normal CountedAverage IMOPSPC BatchCalibration Calibrate CalMethod DeletedReading DeleteWithTag DeleteWithoutTag NewBatch OpenBatch1 BatchCalibration BatchType Menu DeleteLastReading Setup SetLimits Bluetooth About Reset EmergencyLight Calibration Calibrate CalMethod FactoryCalibration CalibrationLock TestCalibration Batch MemoryFree NewBatch OpenExistingBatch ExitBatching EditBatch ReviewBatch DeletedReading Display ClearStatistics ReadingsOnly Readings&SelectedStats Readings&RunChart Readings&BarGraph Statistics ○ ReviewBatch Batch1 Statistics BatchInformation CalibrationInformation Readings CalibrationLock EnablePIN Units µm mm mils inch Statistics ClearStatistics ViewSelected ViewAll SelectStatistics CountedAverage EditBatch ClearBatch DeleteBatch † Probe AutoFNF FerrousF NonFerrousN ProbeSwitchOn † Probe FerrousF1 FerrousF2 Legal Patents LegalNotices Regulatory CalMethod Zero Smooth Rough/2Point ZeroOffset Auto ISO SSPCPA2 Swedish Australian ○ ○ ○ ○ ○ ○ CalMethod Zero Smooth Rough/2Point ZeroOffset Auto ○ ○ ○ SelectStatistics AllPSPCValues NumberofReadings Mean LowestReading HighestReading StandardDeviation CoefficientofVariation LowLimitValue NumberBelowLimit HighLimitValue NumberAboveLimit ElcometerIndexValue NDFTValue %>=NDFT %90-100%NDFT IMO90:10Pass/Fail ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ † Menu displayed is dependent on the probe connected en R www.elcometer.com71 Regulatory QDIDxxxxxx xxxxxx xxxxxx xxxxxx DFTTECH.COM
  • 73. 17 GAUGE MENU STRUCTURES CONTINUED (EBST) Elcometer 456 Model B Display ClearStatistics ReadingsOnly Readings&SelectedStats Readings&BarGraph Statistics † Probe AutoFNF FerrousF NonFerrousN ProbeSwitchOn † Probe FerrousF1 FerrousF2 ○ ○ ○ ○ ○ ○ Setup Units Language BeepVolume ScreenSettings Probe GaugeAutoOff CalibrationLock ScreenSettings ScreenBrightness ScreenTimeout AutoDisplayRotation OpeningScreen About GaugeInformation ProbeInformation Contact Legal CalMethod Zero Smooth Rough/2Point ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Menu DeleteLastReading Setup About Reset EmergencyLight Calibration Calibrate CalMethod FactoryCalibration CalibrationLock○ Data LastFiveReadings 50.5µm 52.3µm 51.0µm 51.8µm 51.5µm EscapeDeleteOk ○ ○ ○ ○ ○ ○ SelectStatistics NumberofReadings Mean LowestReading HighestReading StandardDeviation CoefficientofVariation ElcometerIndexValue CalibrationLock EnablePIN Units µm mm mils inch ○ ○ ○ ○ Legal Patents LegalNotices Regulatory Statistics ClearStatistics ViewSelected ViewAll SelectStatistics CountedAverage † Menu displayed is dependent on the probe connected en R www.elcometer.com 72 Regulatory xxxxx DFTTECH.COM
  • 74. 17 GAUGE MENU STRUCTURES CONTINUED (EBST) Elcometer 456 Model E Setup Units Language Beep Volume Screen Settings Probe Switch On Units µm mm mils inch About Gauge Information Probe Information Contact Legal Menu Setup About Reset Calibration Pressing the Cal Softkey starts the calibration process Screen Settings Screen Brightness ScreenTimeout ○ Legal Patents Legal Notices Regulatory en R www.elcometer.com73 Regulatory xxxxx DFTTECH.COM
  • 75. 18ABOUT IMO PSPC (ST) The Elcometer 456 is capable of displaying PSPC readings according to the 90/10 rule as defined in the International Maritime Organisation (IMO) requirements. To pass the 90/10 rule: At least 90% of all thickness measurements shall be greater than or equal to the NDFT value and; N o n e o f t h e r e m a i n i n g measurements shall be below 0.9 x NDFT. To PASS 90/10 At least 90% of all readings must be in this zone... 90/10 FAILED if Less than 90% of all readings are in this zone... ... no readings must be in this zone ... any readings are in this zone AND OR SUBSTRATE COATING 0.9 x NDFT NDFT While you are taking readings with PSPC selected, your gauge will advise you whether the readings are passing or failing the rule: Ÿ When the PSPC statistics are in the passing state, the reading value is white and the green LED flashes; Ÿ When the PSPC statistics are in the percent fail state, the reading value is white and both the red and green LEDs flash; Ÿ When the PSPC statistics are in the reading fail state, the reading value is red and the red LED flashes. Note: The default value for NDFT is 320µm (12.6mils) - from PSPC for Ballast Water Tanks. Note: The 90/10 rule is not compatible with the counted average data collection method (see Batching on page 26) and cannot be used when saving readings using this method. en R www.elcometer.com 74 DFTTECH.COM
  • 76. 19 GAUGE TECHNICALSPECIFICATIONS (EBST) Display Information 60mm (2.4") QVGA colour TFT display, 320 x 240 pixels Battery Type 2 x AA dry cell batteries, rechargeable batteries can also be used Battery Life ~24 hours of continuous use at 1 reading per second Using default settings & lithium batteries, alkaline or rechargeable batteries may differ Gauge Dimensions (h x w x d) Integral: 141 x 73 x 37mm (5.55 x 2.87 x 1.46") Separate: 141 x 73 x 37mm (5.55 x 2.87 x 1.46") Gauge Weight (including supplied batteries) Integral: 156g (5.5oz) Separate: 161g (5.68oz) Operating Temperature -10 to 50°C (14 to 122°F) 73mm (2.87") 141mm(5.55") 60mm (2.4") 37mm (1.46") en R www.elcometer.com75 DFTTECH.COM
  • 77. 20 PROBE TECHNICALSPECIFICATIONS (EBST) Available in a number of designs and scale ranges, all probes are supplied with an Elcometer test certificate and a set of calibration foils appropriate to the scale range. Ferrous probes measure non magnetic coatings on ferro-magnetic substrates. Non- ferrous probes measure non conductive coatings on non-ferrous metal substrates. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Range 0 - 1500µm (0 - 60mils) Resolution 0.1µm: 0 - 100µm; 1µm: 100 - 1500µm (0.01mil: 0 - 5mils; 0.1mil: 5 - 60mils) Accuracy ±1-3% or ±2.5µm (±1-3% or ±0.1mil) Probe Design Minimum Convex Surface Diameter Minimum Concave Surface Radius Minimum Headroom Minimum Sample Diameter Straight Ferrous 4mm (0.16") 25mm (0.98") 85mm (3.35") 4mm (0.16") Ferrous Sealed 4mm (0.16") 25mm (0.98") 85mm (3.35") 4mm (0.16") Non-Ferrous 10mm (0.39") 10mm (0.39") 85mm (3.35") 4mm (0.16") Dual FNF F Mode: 4mm (0.16") N Mode: 26mm (1.02") 12.5mm (0.49") 88mm (3.46") F Mode: 4mm (0.16") N Mode: 6mm (0.24") Right Angle Ferrous 4mm (0.16") 25mm (0.98") 28mm (1.10") 4mm (0.16") Non-Ferrous 10mm (0.39") 14mm (0.55") 28mm (1.10") 4mm (0.16") Dual FNF F Mode: 4mm (0.16") N Mode: 26mm (1.02") 12.5mm (0.49") 38mm (1.50") F Mode: 4mm (0.16") N Mode: 6mm (0.24") Anodiser Non-Ferrous 10mm (1.38") 14mm (0.55") 100mm (3.94") 4mm (0.16") PINIP Ferrous 4mm (0.16") 60mm (2.36") 170mm (6.69") 4mm (0.16") Non-Ferrous 10mm (0.39") 50mm (1.97") 180mm (7.09") 4mm (0.16") Dual FNF F Mode: 4mm (0.16") N Mode: 26mm (1.02") 65mm (2.56") 180mm (7.09") F Mode: 4mm (0.16") N Mode: 6mm (0.24") Minimum Substrate Thickness Ferrous: Non-Ferrous: 0.3mm (12mils) 0.1mm (4mils) Maximum Operating Temperature (limited duty cycle) Ferrous: Non-Ferrous: PINIP: PINIP (High Temp): 150°C (300°F) 80°C (176°F) 80°C (176°F) 250°C (480°F) Storage Temperature -10 to 60°C (14 to 140°F) SCALE 1 * Whichever is the greater en R www.elcometer.com 76 DFTTECH.COM