Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG includes 6 widely spaced NEMA5-15R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment.
Features:
Tripp Lite's IS1800HG Hospital Grade isolation transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression
Internal low-impedence isolation transformer with Faraday shield offers 100% isolation from the input AC line
Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. -Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps.
Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops
Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels
Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
Includes 6 widely spaced NEMA5-20R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch
Ships with NEMA5-20P input plug installed, package includes NEMA5-15P user installable hospital grade replacement plug for compatiblity with common 15A wall receptacle
Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment
2-year limited product warranty
Specifications:
Nominal Voltage /
Frequency |
|
120V / 60Hz |
|
VA / Watt Capacity |
|
1800 |
|
Amp Capacity |
|
15A at 120V AC |
|
Transformer Type |
|
Hospital Grade, low
impedence transformer-based line isolation transformer |
|
Total Harmonic
Distortion |
|
less than 1% |
|
Over Current Protection |
|
Yes, 20A circuit breaker |
|
Output Receptacle Qty /
Type |
|
6 NEMA 5-20R Hospital
Grade Outlets |
|
Input Plug Type |
|
NEMA 5-20P Hospital Grade
Plug |
|
Input Cord Length |
|
6.00 ft. / 1.83 m |
|
Leakage Current |
|
less than 300 microamps |
|
Efficiency |
|
96% |
|
Suppression Joule Rating |
|
1190 (1020 input / 170
output) |
|
Noise Suppression Rating |
|
35-65 DB |
|
Surge Test Conditions |
|
Per ANSI/IEEE C62.41 -
IEEE587 Cat. A & B test waveforms |
|
Let-through Voltage
(Ring Wave) |
|
L-N: 20V L-G: 20V N-G: 0.5V |
|
Let-through Voltage
(Combination Wave) |
|
L-N: 250V L-G: 250V N-G:
0.5V |
|
Cooling Method |
|
Convection |
|
Form Factor |
|
Small tower format |
|
Unit Dimensions
(HWD/in.) |
|
7.75 x 8.25 x 12.25 |
|
Shipping Weight |
|
58.00 lbs. / 26.31 kg |
|
Warranty |
|
2-year limited product
warranty |
|
Approvals |
|
UL (UL Series