Cisco UCS C200 M2 Spec Sheet

Cisco UCS C200 M2 Spec Sheet

High-density small form factor drive rack-mount server
Hide thumbs Also See for UCS C200 M2:

Advertisement

This product has been
discontinued
Cisco UCS C200 M2
High-Density
Small Form Factor Drive
Rack-Mount Server
C
S
ISCO
YSTEMS
170 W
T
D
.
EST
ASMAN
R
S
J
, CA, 95134
AN
OSE
.
.
WWW
CISCO
COM
P
H
UBLICATION
ISTORY
R
A.14
M
16, 2013
EV
AY
Spec Sheet

Advertisement

Table of Contents
loading

Summary of Contents for Cisco UCS C200 M2

  • Page 1 This product has been Spec Sheet discontinued Cisco UCS C200 M2 High-Density Small Form Factor Drive Rack-Mount Server ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 A.14 16, 2013 CISCO...
  • Page 2: Table Of Contents

    Compliance Requirements ..........59 Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 3: Overview

    (1RU) rack server that extends the capabilities of the Cisco Unified Computing System™. The server uses Intel's latest Xeon 5600 Series multi-core processors with 12 DIMM slots and 2 PCIe slots. The UCS C200 M2 SFF Server is available with eight 2.5-inch SFF hard disk drives or solid-state drives. Figure 1...
  • Page 4: Detailed Views

    DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C200 M2 High-Density SFF Rack Server front panel with the standard front panel control module installed. Figure 3 shows the server with the optional DVD-RW optical drive module you can configure in place of the front panel control module.
  • Page 5: Chassis Rear View

    10/100 Ethernet management port (RJ-45) 10/100/1000 Gigabit Ethernet ports (2) USB 2.0 connectors (2) Low-profile PCIe card slot (PCIe slot 7) Serial connector (DB9) Standard-profile PCIe card slot (PCIe slot 6) Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 6: Base Server Standard Capabilities And Features

    Up to eight 2.5-inch SAS or SATA hot-swappable HDDs or solid state ■ drives (SSDs) USB connector on motherboard ■ Video 1280 x 1024 resolution ■ 32-bit color depth ■ 8 MB video memory ■ Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 7 Each power supply is equipped with a fan. ■ Integrated management Cisco Integrated Management Controller (CIMC) (with integrated video, KVM processor redirection, Security Intelligence Operations (SIO), fan speed control, Platform Environment Control Interface (PECI), and voltage monitoring) Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 8: Configuring The Server

    CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C200 M2 High-Density SFF Rack Server: STEP 1 VERIFY BASE SKU, page 9 ■ STEP 2 SELECT CPU(s), page 10 ■ STEP 3 SELECT MEMORY, page 12 ■...
  • Page 9: Step 1 Verify Base Sku

    Does not include CPU, memory, hard disk drives (HDDs), solid-state drives (SSDs), plug-in ■ PCIe cards, or DVD-RW drive. NOTE: Use the steps on the following pages to configure the server with the components that you want to include. Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 10: Step 2 Select Cpu(S)

    DIMMs, the DIMMs will be clocked at the lower speed of 1066 MHz. Selecting higher-speed DIMMs: If you use 1333-MHz DIMMs with an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 11 For optimal performance, select DIMMs with the highest clock speed for a given processor ■ (see Table 3 on page 10). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 12: Step 3 Select Memory

    DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per ■ channel, as shown in Figure Figure 5 C200 M2 SFF Memory Organization Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 13 DIMM Placement in Channels DIMMs (Channel C is not used with memory mirroring) 1 DIMM in Channel A, 1 DIMM in Channel B 2 DIMMs in Channel A, 2 DIMMs in Channel B Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 14 If you select the Memory RAS option, be aware that it is available only with an even number of memory channels. For example, if you select six DIMMs and select Reliability/Availability/Serviceability (RAS), mirroring will go into effect on only two Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 15 4-GB and two 8-GB DIMMs. One 4-GB/8-GB DIMM pair would located on Channel A of CPU 1, and one 4-GB/8-GB DIMM pair would be located on Channel B of CPU 1. For more information regarding memory, see CPUs and DIMMs, page Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 16: Step 4 Select Raid Configuration

    PCIe cards or an optional mezzanine board on the server motherboard. Cisco can provide factory-configured RAID 0, 1, 1E, 5, 6, and 10 systems depending on the RAID card chosen and the number of drives ordered. Factory-configured RAID options are listed with each RAID card description.
  • Page 17 Table 5 Available RAID Options (continued) Product ID (PID) PID Description UCSC-RAID-SFFC200 LSI 1068E 8-port SAS 3.0G RAID Mezzanine Installed on the mezzanine connector inside the UCS C200 M2 server ■ Supports up to eight SAS or SATA hard disk drives ■ No battery backup.
  • Page 18 You can choose an optional RAID configuration (RAID 0, 1, 5, 1E, 6, or 10), which is ■ preconfigured at the factory. If you do not choose a RAID configuration, the disks will be configured as a JBOD. Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 19: Step 5

    900 GB 6 Gb SAS 10K RPM SFF HDD 900 GB A03-D1TBSATA 1 TB SATA 7.2K RPM SFF HDD SATA 1 TB SSDs UCS-SSD100GI1F104 NEW 100GB SATA SSD SFF (STEC) SATA 100 GB Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 20 If you selected a RC460-PL001 MegaRAID controller or the UCSC-RAID-SFFC200 mezzanine ■ card RAID controller, you can select up to eight SAS or SATA drives. You cannot mix HDDs and SSDs. ■ Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 21: Step 6 Select Pcie Option Card(S)

    N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half N2XX-AQPCI03 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 22 All cards will fit in either slot, except the VIC card, which must be installed in the full-height slot (slot 6). To help ensure that your operating system is compatible with the card you have selected, ■ check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 23: Step 7 Order Optional Network Card Accessories

    N2XX-ACPCI01 (Cisco UCS P81E Virtual Interface Card/ 2-port 10Gbps) — UCS-PCIE-BSFP (Broadcom 57712) — N2XX-ABPCI02 (Broadcom 57711) — N2XX-AEPCI01 (Emulex OCe10102-F) — N2XX-AIPCI01 (Intel Dual Port Ethernet X520) — N2XX-AQPCI01 (Qlogic QLE 8152-CNA) Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 24 PCIe cards, as they do not come by default with any opical modules: — N2XX-AEPCI05 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA) Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 25 CONFIGURING the SERVER Figure 6 Network Card Connections Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 26: Step 8 Select Optional Dvd-Rw Drive

    Product ID (PID) PID Description UCSC-CON-SFF-C200 Controller panel for UCS C200 SFF Rack Server UCSC-DVD-SFF-C200 DVD-RW Drive for UCS C200 M2 SFF Rack Server Approved Configurations (1) Select the controller panel, or (2) Select the optional DVD-RW optical drive Caveats The DVD-RW optical drive is optional.
  • Page 27: Step 9 Order Optional Redundant Power Supply

    One 650 W power supply ships with the base server chassis. You can order an optional redundant power supply (see Table 11). Table 11 Redundant Power Supply Product ID (PID) PID Description R2X0-PSU2-650W-SB Redundant 650 W power supply. Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 28: Step 10 Select Ac Power Cord(S)

    CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug, Australia Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: EL 701C Plug: EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 29 Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: Plug: EL 701C EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 30 Table 12 Available Power Cords Product ID (PID) PID Description Images CAB-9K12A-NA Power Cord, 125VAC 13A NEMA Image not available 5-15 Plug, North America CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 31: Step 11 Order Optional Tool-Less Rail Kit

    CONFIGURING the SERVER STEP 11 ORDER OPTIONAL TOOL-LESS RAIL KIT A rail kit is not included with the Cisco UCS C200 M2 base server chassis, but you can order the tool-less rail kit listed in Table Table 13 Rail Kit...
  • Page 32: Step 12 Order Optional Cable Management Arm

    PID Description R2XX-CMAG3-1032 Cable Mgmt Arm for R2XX-G31032RAIL for C200/C210 For more information about the cable management arm, see the Cisco UCS C200 Installation and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C200M1/install/c200M1.html Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 33: Step 13 Order A Trusted Platform Module

    The TPM ordering information is listed in Table Table 15 Trusted Platform Module Product ID (PID) PID Description R200-TPM1 Trusted Platform Module Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 34: Step 14 Select Operating System And Value-Added Software

    Windows Server 2012 Standard (2 CPU/2 VMs) MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco Svc SUSE Linux Enterprise Server...
  • Page 35 VMware vCenter 5 Server Standard, 1 yr support required  VMW-VC5-STD-2A VMware vCenter 5 Server Standard, 2 yr support required  VMW-VC5-STD-3A VMware vCenter 5 Server Standard, 3 yr support required  VMW-VC5-STD-4A VMware vCenter 5 Server Standard, 4 yr support required  Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 36 Table 16 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required  UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers  Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 37: Step 15 Select Operating System Media Kit

    Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media MSWS-12-DC2S-RM Windows Server 2012 Datacenter(2 CPU/Unlimited VM) Rec Media Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 38: Step 16 Select Service And Support Level

    UC Mission Critical 24x7x2 On-site Unified Computing Support Service For support of the entire Cisco Unified Computing System, Cisco offers the Cisco Unified Computing Support Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to the Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
  • Page 39 CONFIGURING the SERVER two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in Table Table 19 UCS Computing Support Service...
  • Page 40 With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
  • Page 41 CON-UCWD7-R200WSFF UCWD8 24x7x2 Onsite CON-UCWD8-R200WSFF For more service and support information, see this URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 42: Optional Step - Order Rack(S)

    OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including theC200 M2 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as...
  • Page 43: Optional Step - Order Pdu

    OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC200 M2 server. This PDU is available in a zero rack unit (RU) style (see Table 22).
  • Page 44: Supplemental Material

    SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C200 M2 chassis with the top cover removed is shown in Figure Figure 7 C200 M2 SFF With Top Cover Off Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 45: Cpus And Dimms

    F) are associated with CPU2. The Bank 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding Bank 2 (black) slots. Bank 1 slots are populated before Bank 2 slots. Figure 8 CPU DIMM Channels and Banks Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 46: Memory Population Rules

    That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage DIMMs. CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage ■ DIMMs operating in Power Saving Mode only, and do not support Performance Mode. Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 47: Recommended Configurations

    96 GB (1 CPU) 3 x 16 GB 3 x 16 GB 3 x 16 GB 3 x 16 GB 800 MHz 192 GB (2 CPUs) Notes . . . 1. Best performance configuration Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 48: Configuration Samples

    Configuration Samples Figure 9 Figure 10 on page 49 show examples of how DIMMs are populated for 1-CPU and 2-CPU systems. Figure 9 Example of 24-GB DIMM Memory Combinations with One CPU Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 49 SUPPLEMENTAL MATERIAL Figure 10 Example of 96-GB DIMM Memory Combinations with Two CPUs Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 50: Racks

    SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 11) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches ■...
  • Page 51 SUPPLEMENTAL MATERIAL Figure 11 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 52: Pdus

    With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
  • Page 53: Power Supplies

    SUPPLEMENTAL MATERIAL POWER SUPPLIES The C200 M2 can accommodate one or two 650 W power supplies. A typical power supply is shown in Figure Figure 13 C200 M2 Power Supply Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 54: Kvm Cable

    Product ID (PID) PID Description 37-1016-01 KVM Cable Figure 14 KVM Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB connector (for a mouse and keyboard) Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 55: Motherboard Usb Port

    The C200 M2 SFF motherboard has a general-purpose USB socket, as shown in Figure 15. Cisco offers a 4 GB USB drive that is compatible with this socket. You can order it as a spare (PID = UCS-USBFLSH-S-4GB=). Figure 15 Motherboard USB Port Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 56: Technical Specifications

    Power supply output voltage Main power: 12 VDC Standby Power: 5 VDC Power supply efficiency 92% Peak, complies with 80Plus Gold Standard NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 57 TECHNICAL SPECIFICATIONS For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/. As an example, using the calculator, we can determine the approximate power for the following C200 M2 SFF server configuration: Voltage = 115 VAC ■...
  • Page 58: Environmental Specifications

    Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact discharge without physical damage Acoustic Sound power: 54.7 dBA (5.7 Bels) at ambient temperature 23°C measured using the Dome Method GOST MsanPiN 001-96 Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 59: Compliance Requirements

    AS/NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EMC - Immunity EN55024 CISPR24 EN300386 KN24 Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...
  • Page 60 TECHNICAL SPECIFICATIONS Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server...

Table of Contents