// CODE SNIPPET
(c) Branch Vents
Go To Full Code Chapter
Branch vents connecting more than one individual vent to a stack or stack-vent shall be in accordance with Table RS 16-14. The branch vent size shall be based upon the number of fixture units connected thereto, and the developed length of the branch vent measured from its vent stack (or stack-vent) connection to the farthest fixture drain connection served by the branch vent. See Figure RS 16-2.
Figure RS 16-2. Sizing of Branch Vent Piping, Drop Vents to 1st Floor, Basement and Cellar Fixtures.
Related Code Sections
(c) Plumbing and Gas Piping, Branch Vents
Branch vents connecting more than one individual vent to a stack or stack-vent shall be in accordance with Table RS 16-14. The branch vent size shall ...
906.4 Vents, Multiple Branch Vents
Where multiple branch vents are connected to a common branch vent, the common branch vent shall be sized in accordance with this section based ...
916.4 Vents, Multiple Branch Vents
Where multiple branch vents are connected to a common branch vent, the common branch vent shall be sized in accordance with this section based ...
916.4 Vents, Multiple Branch Vents
Where multiple branch vents are connected to a common branch vent, the common branch vent shall be sized in accordance with this section based ...
Section PC 911 Vents, Circuit Venting
A maximum of eight fixtures connected to a horizontal branch drain shall be permitted to be circuit vented. Each fixture drain shall connect ...