Setup Overview

for the HPE ProLiant ML350 Gen9 Server

HPE ProLiant ML350 Gen9 Server

Before you begin

  • For safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products on the Hewlett Packard Enterprise website.
  • Select an installation site that meets the detailed installation site requirements described in the server user guide.
  • Unpack the server shipping carton, and locate the materials and documentation necessary for installing the server.
  • Verify operating system support—For information about operating systems supported by ProLiant servers, see the operating system support matrices.

For more pre-installation information, see the HPE ProLiant ML350 Gen9 Server User Guide on the Hewlett Packard Enterprise website.

Component identification

Front panel components

  • SFF model (tower orientation)

    Front panel components (SFF)

    Item

    Description

    1

    SFF SAS/SATA drives

    2

    Serial label pull tab*

    3

    Drive cage bays

    4

    Optical drive bay

    5

    Media/drive cage bays

    6

    USB 2.0 connectors (2)

    *The serial label pull tab is double-sided. One side shows the server serial number, and the other side shows the default iLO account information. The same information is printed on a label attached to the chassis.

  • SFF model (rack orientation)

    Front panel components_SFF_rack

    Item

    Description

    1

    SFF SAS/SATA drives

    2

    Serial label pull tab*

    3

    Drive cage bays

    4

    Optical drive bay

    5

    Media/drive cage bays

    6

    Systems Insight Display bay

    7

    USB 2.0 connectors (2)

    *The serial label pull tab is double-sided. One side shows the server serial number, and the other side shows the default iLO account information. The same information is printed on a label attached to the chassis.

  • LFF model (tower orientation)

    Front panel components (LFF)

    Item

    Description

    1

    Media/drive cage bay

    2

    Drive cage bay

    3

    Serial label pull tab*

    4

    LFF SAS/SATA drives

    5

    Optical drive bay

    6

    USB 2.0 connectors (2)

    *The serial label pull tab is double-sided. One side shows the server serial number, and the other side shows the default iLO account information. The same information is printed on a label attached to the chassis.

  • LFF model (rack orientation)

    Front panel components_LFF_rack

    Item

    Description

    1

    Media/drive cage bay

    2

    Drive cage bay

    3

    Serial label pull tab*

    4

    LFF SAS/SATA drives

    5

    Optical drive bay

    6

    USB 2.0 connectors (2)

    7

    Systems Insight Display bay

    *The serial label pull tab is double-sided. One side shows the server serial number, and the other side shows the default iLO account information. The same information is printed on a label attached to the chassis.

    For more information on box and drive numbering, see "Device numbering" in the HPE ProLiant ML350 Gen9 User Guide.

Front panel LEDs and buttons

Front panel LEDs and buttons

Item

Description

Status

1

UID button/LED

Solid blue = Activated

Flashing blue:

  • 1 flash per second = Remote management or firmware upgrade in progress
  • 4 flashes per second = iLO manual reboot sequence initiated
  • 8 flashes per second = iLO manual reboot sequence in progress

    Off = Deactivated

2

Health LED

Solid green = Normal

Flashing green (1 flash per second) = iLO is rebooting

Flashing amber = System degraded

Flashing red (1 flash per second) = System critical

 

If the health LED indicates a degraded or critical state, review the system IML or use iLO to review the system health status.

3

NIC status LED

Solid green = Link to network

Flashing green (1 flash per second) = Network active

Off = No network activity

4

Power On/Standby button and system power LED

Solid green = System on

Flashing green (1 flash per second) = Performing power on sequence

Solid amber = System in standby

Off = No power present

 

Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the front I/O cable is disconnected.

When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see "Front panel LED power fault codes" in the HPE ProLiant ML350 Gen9 User Guide.

Rear panel components

Rear panel components

Item

Description

1

Slot 1 PCIe3 x16 (8, 4, 1) (processor 1)

2

Slot 2 PCIe3 x8 (4, 1) (processor 1)

3

Slot 3 PCIe3 x16 (16, 8, 4, 1) (processor 1)

4

Slot 4 PCIe3 x8 (4, 1) (processor 1)

5

Padlock hole

6

NIC connector 2

7

Kensington lock slot

8

NIC connector 4

9

Serial connector

10

Slot 5 PCIe2 x8 (4, 1) (processor 2)

11

Slot 6 PCIe3 x16 (16, 8, 4, 1) (processor 2)

12

Slot 7 PCIe3 x8 (4, 1) (processor 2)

13

Slot 8 PCIe3 x16 (16, 8, 4, 1) (processor 2)

14

Slot 9 PCIe3 x8 (4, 1) (processor 2)

15

Power supply 4

16

Video connector

17

Power supply 3

18

iLO connector

19

NIC connector 3

20

NIC connector 1

21

Power supply 2

22

USB 2.0 connectors (2)

23

USB 3.0 connectors (2)

24

Power supply 1

Rear panel LEDs

Rear panel LEDs

Item

Description

Status

1

NIC activity LED

Solid green = Link to network

Flashing green = Network active

Off = No network activity

2

NIC link LED

Green = Network link

Off = No network link

3

Power supply LED

Solid green = Normal

Off = One or more of the following conditions exists:

  • Power is unavailable
  • Power supply failed
  • Power supply is in standby mode
  • Power supply error

4

iLO link LED

Green = Linked to network

Off = No network connection

5

iLO activity LED

Green or flashing green = Network activity

Off = No network activity

6

UID LED

Solid blue = Activated

Flashing blue:

  • 1 flash per second = Remote management or firmware upgrade in progress
  • 4 flashes per second = iLO manual reboot sequence initiated
  • 8 flashes per second = iLO manual reboot sequence in progress

    Off = Deactivated

Install hardware options

Installing hardware options

Install any hardware options before initializing the server. For options installation information, see the documentation that ships with the option. For server-specific information, see the HPE ProLiant ML350 Gen9 Server User Guide on the Hewlett Packard Enterprise website.

Connect cabling and power cords

  1. Connect iLO management cabling.

    Connecting the dedicated iLO cabling

  2. Connect the network cabling.

    Connecting the network cabling

  3. Connect the power cord to the power supply.

    Connecting the power cord

    WARNING: To reduce the risk of electric shock or damage to the equipment:

    • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
    • Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
    • Unplug the power cord from the power supply to disconnect power to the equipment.
    • Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.

     

For more information about cabling the system, see the HPE ProLiant ML350 Gen9 Server User Guide on the Hewlett Packard Enterprise website.

Power up and select boot options

On servers operating in UEFI Boot Mode, the boot controller and boot order are set automatically.

  1. Press the Power On/Standby button.
  2. During the initial boot:
    • To modify the server configuration ROM default settings, press the F9 key in the ProLiant POST screen to enter the UEFI System Utilities screen. By default, the System Utilities menus are in the English language.
    • If you do not need to modify the server configuration and are ready to install the system software, press the F10 key to access Intelligent Provisioning.

For more information on automatic configuration, see the UEFI documentation on the Hewlett Packard Enterprise website.

Install the system software

This ProLiant server does not ship with provisioning media. Everything needed to manage and install the system software and firmware is preloaded on the server.

To operate properly, the server must have a supported operating system. Attempting to run an unsupported operating system can cause serious and unpredictable results. For the latest information on operating system support, see the Hewlett Packard Enterprise website.

Failure to observe UEFI requirements for ProLiant Gen9 servers can result in errors installing the operating system, failure to recognize boot media, and other boot failures. For more information on these requirements, see the HPE UEFI Requirements on the Hewlett Packard Enterprise website.

To install an operating system on the server, use one of the following methods:

  • Intelligent Provisioning—For single-server deployment, updating, and provisioning capabilities.

    To install an operating system on the server with Intelligent Provisioning (local or remote):

    1. Connect the Ethernet cable between the network connector on the server and a network jack.
    2. Press the Power On/Standby button.
    3. During server POST, press F10.
    4. Complete the initial Preferences and Registration portion of Intelligent Provisioning.
    5. At the 1 Start screen, click Configure and Install.
    6. To finish the installation, follow the onscreen prompts. An Internet connection is required to update the firmware and systems software.
  • Insight Control server provisioning—For multi-server remote OS deployment, use Insight Control server provisioning for an automated solution. For more information, see the Insight Control documentation on the Hewlett Packard Enterprise website.

For additional system software and firmware updates, download the Service Pack for ProLiant from the Hewlett Packard Enterprise website. Software and firmware must be updated before using the server for the first time, unless any installed software or components require an older version.

Register the server

To experience quicker service and more efficient support, register the product at the Hewlett Packard Enterprise Product Registration website.

Additional information

For more information, see the HPE ProLiant ML350 Gen9 documentation in the Hewlett Packard Enterprise Information Library.

For important safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise website.

Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback. When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page.

Part number: 781897-003
August 2018
Edition: 4